WorldWideScience

Sample records for values ppv npv

  1. Increasing Shareholders Value through NPV-Negative Projects

    Directory of Open Access Journals (Sweden)

    Paweł Mielcarz

    2010-10-01

    Full Text Available The concept of Net Present Value (NPV is a widely accepted tool for verification of financial rationality of planned investment projects. Projects with positive NPV increase a company's value. Similarly, those with negative NPV lead to a decline in the value of a business. This article attempts to answer the question: are projects with negative NPV always disadvantageous in terms of maximization of shareholder value and when should an NPV-negative project be considered justified? The authors discuss the issues of project valuation depending on different conditions. First, they briefly summarize the main idea of valuation - the aim of every company is to maximize shareholder value. Contemporary professional texts say that the way to achieve this goal is through projects that can generate a positive Net Present Value. When there are no such investments within reach, the company should pay dividends to its owners. The authors claim that some circumstances justify investments with a negative Net Present Value, as they still produce maximum possible shareholder value. The three model situations where this takes place are: (1 tax on dividends; (2 shareholders' perception of risk; and (3 temporary inefficiency of the markets. Taxes on dividends reduce cashflows for shareholders from distributed dividends. Therefore, they act exactly as an investment with a negative NPV. The authors conclude that this creates an opportunity to maximize shareholder value by comparing this loss with available alternate projects with negative NPV. If the loss of worth, caused by such taxes, is bigger that the negative NPV of possible investments it will be more rational to invest instead of paying dividends. And, according to the authors, a project with a negative NPV leads to maximized shareholder value. In the second situation, the authors point out that some projects may have negative fundamental (intrinsic value when valuated by the market (diversified owners because

  2. The value of precontrast thoraco-abdominopelvic CT in polytrauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Esposito, A.A., E-mail: rxandreaesposito@yahoo.it [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy); Zilocchi, M., E-mail: massimo.zilocchi@gmail.com [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy); Fasani, P., E-mail: fasapier65@gmail.com [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy); Giannitto, C., E-mail: caterina.giannitto@gmail.com [School of Radiology, University of Milan, Via A. di Rudinì 8, Milan (Italy); Maccagnoni, S., E-mail: maccagnnisara@libero.it [School of Radiology, University of Milan, Via A. di Rudinì 8, Milan (Italy); Maniglio, M., E-mail: marinamaniglio@gmail.com [School of Radiology, University of Milan, Via A. di Rudinì 8, Milan (Italy); Campoleoni, M., E-mail: campoleoni@policlinico.mi.it [Medical Phisic Unit, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20121 Milan (Italy); Brambilla, R., E-mail: roberto.brambilla@policlinico.mi.it [Medical Phisic Unit, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20121 Milan (Italy); Casiraghi, E., E-mail: casiraghi@di.unimi.it [Computer Science Department, University of Milan, Via Comelico 39, Milan (Italy); Biondetti, P.R., E-mail: pibionde@tin.it [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy)

    2015-06-15

    Highlights: • We evaluated the additional value of precontrast CT in polytrauma patient. • We evaluated the radiation dose CT in polytrauma patient. • Precontrast CT scan does not have an additional value in polytrauma patient. • Precontrast CT expose patient to an unjustified radiation dose. - Abstract: Purpose: To evaluate the utility and radiation dose of thoraco-abdominopelvic precontrast CT in polytrauma patients. Materials and methods: We examined retrospectively 125 patients who underwent a thoraco-abdominopelvic CT for trauma. Two radiologists, independently, evaluated precontrast CT acquisition and two other radiologists examined the contrast-enhanced scans. A further two radiologists assessed both the acquisitions. Mean value of sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) were calculated by each group of radiologists. For 104 patients, CTDIvol, DLP data and individual mean size were collected to calculate effective dose. Results: Mean values of SE, SP, PPV and NPV of findings of radiologists who assessed contrast-enhanced acquisitions were respectively: SE = 85%, SP = 98%, PPV = 86%, NPV = 88% versus: SE = 43%, SP = 95%, PPV = 69%, NPV = 88% of radiologists who examined non-contrast-enhanced scans. Mean values of radiologists who analyzed both acquisitions were: SE = 80%, SP = 97%, PPV = 80%, NPV = 88%. Neither the precontrast scans nor the precontrast and postcontrast scans together provided additional useful information compared to the single contrast-enhanced acquisition. Patients received a mean dose of 12 mSv for the precontrast CT. Conclusions: Precontrast CT acquisition did not provide significant information in trauma patients, exposing them to an unjustified radiation dose.

  3. The value of precontrast thoraco-abdominopelvic CT in polytrauma patients

    International Nuclear Information System (INIS)

    Esposito, A.A.; Zilocchi, M.; Fasani, P.; Giannitto, C.; Maccagnoni, S.; Maniglio, M.; Campoleoni, M.; Brambilla, R.; Casiraghi, E.; Biondetti, P.R.

    2015-01-01

    Highlights: • We evaluated the additional value of precontrast CT in polytrauma patient. • We evaluated the radiation dose CT in polytrauma patient. • Precontrast CT scan does not have an additional value in polytrauma patient. • Precontrast CT expose patient to an unjustified radiation dose. - Abstract: Purpose: To evaluate the utility and radiation dose of thoraco-abdominopelvic precontrast CT in polytrauma patients. Materials and methods: We examined retrospectively 125 patients who underwent a thoraco-abdominopelvic CT for trauma. Two radiologists, independently, evaluated precontrast CT acquisition and two other radiologists examined the contrast-enhanced scans. A further two radiologists assessed both the acquisitions. Mean value of sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) were calculated by each group of radiologists. For 104 patients, CTDIvol, DLP data and individual mean size were collected to calculate effective dose. Results: Mean values of SE, SP, PPV and NPV of findings of radiologists who assessed contrast-enhanced acquisitions were respectively: SE = 85%, SP = 98%, PPV = 86%, NPV = 88% versus: SE = 43%, SP = 95%, PPV = 69%, NPV = 88% of radiologists who examined non-contrast-enhanced scans. Mean values of radiologists who analyzed both acquisitions were: SE = 80%, SP = 97%, PPV = 80%, NPV = 88%. Neither the precontrast scans nor the precontrast and postcontrast scans together provided additional useful information compared to the single contrast-enhanced acquisition. Patients received a mean dose of 12 mSv for the precontrast CT. Conclusions: Precontrast CT acquisition did not provide significant information in trauma patients, exposing them to an unjustified radiation dose

  4. Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients.

    Science.gov (United States)

    Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes

    2011-01-01

    To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.

  5. Addendum to the article: Misuse of null hypothesis significance testing: Would estimation of positive and negative predictive values improve certainty of chemical risk assessment?

    Science.gov (United States)

    Bundschuh, Mirco; Newman, Michael C; Zubrod, Jochen P; Seitz, Frank; Rosenfeldt, Ricki R; Schulz, Ralf

    2015-03-01

    We argued recently that the positive predictive value (PPV) and the negative predictive value (NPV) are valuable metrics to include during null hypothesis significance testing: They inform the researcher about the probability of statistically significant and non-significant test outcomes actually being true. Although commonly misunderstood, a reported p value estimates only the probability of obtaining the results or more extreme results if the null hypothesis of no effect was true. Calculations of the more informative PPV and NPV require a priori estimate of the probability (R). The present document discusses challenges of estimating R.

  6. Diagnostic accuracy of an MRI protocol of the knee accelerated through parallel imaging in correlation to arthroscopy

    International Nuclear Information System (INIS)

    Schnaiter, Johannes Walter; McKenna-Kuettner, Axel; Roemer, Frank; May, Matthias Stefan; Janka, Rolf; Uder, Michael; Wuest, Wolfgang; Patzak, Hans-Joachim

    2018-01-01

    Parallel imaging allows for a considerable shortening of examination times. Limited data is available about the diagnostic accuracy of an accelerated knee MRI protocol based on parallel imaging evaluating all knee joint compartments in a large patient population compared to arthroscopy. 162 consecutive patients with a knee MRI (1.5 T, Siemens Aera) and arthroscopy were included. The total MRI scan time was less than 9 minutes. Meniscus and cartilage injuries, cruciate ligament lesions, loose joint bodies and medial patellar plicae were evaluated. Sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV), as well as diagnostic accuracy were determined. For the medial meniscus, the values were: SE 97 %, SP 88 %, PPV 94 %, and NPV 94 %. For the lateral meniscus the values were: SE 77 %, SP 99 %, PPV 98 %, and NPV 89 %. For cartilage injuries the values were: SE 72 %, SP 80 %, PPV 86 %, and NPV 61 %. For the anterior cruciate ligament the values were: SE 90 %, SP 94 %, PPV 77 %, and NPV 98 %, while all values were 100 % for the posterior cruciate ligament. For loose bodies the values were: SE 48 %, SP 96 %, PPV 62 %, and NPV 93 %, and for the medial patellar plicae the values were: SE 57 %, SP 88 %, PPV 18 %, and NPV 98 %. A knee MRI examination with parallel imaging and a scan time of less than 9 minutes delivers reliable results with high diagnostic accuracy.

  7. FDG-PET Response Prediction in Pediatric Hodgkin’s Lymphoma: Impact of Metabolically Defined Tumor Volumes and Individualized SUV Measurements on the Positive Predictive Value

    Energy Technology Data Exchange (ETDEWEB)

    Hussien, Amr Elsayed M. [Department of Nuclear Medicine (KME), Forschungszentrum Jülich, Medical Faculty, Heinrich-Heine-University Düsseldorf, Jülich, 52426 (Germany); Department of Nuclear Medicine, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225 (Germany); Furth, Christian [Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University Magdeburg, Magdeburg, 39120 (Germany); Schönberger, Stefan [Department of Pediatric Oncology, Hematology and Clinical Immunology, University Children’s Hospital, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225 (Germany); Hundsdoerfer, Patrick [Department of Pediatric Oncology and Hematology, Charité Campus Virchow, Humboldt-University Berlin, Berlin, 13353 (Germany); Steffen, Ingo G.; Amthauer, Holger [Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University Magdeburg, Magdeburg, 39120 (Germany); Müller, Hans-Wilhelm; Hautzel, Hubertus, E-mail: h.hautzel@fz-juelich.de [Department of Nuclear Medicine (KME), Forschungszentrum Jülich, Medical Faculty, Heinrich-Heine-University Düsseldorf, Jülich, 52426 (Germany); Department of Nuclear Medicine, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225 (Germany)

    2015-01-28

    Background: In pediatric Hodgkin’s lymphoma (pHL) early response-to-therapy prediction is metabolically assessed by (18)F-FDG PET carrying an excellent negative predictive value (NPV) but an impaired positive predictive value (PPV). Aim of this study was to improve the PPV while keeping the optimal NPV. A comparison of different PET data analyses was performed applying individualized standardized uptake values (SUV), PET-derived metabolic tumor volume (MTV) and the product of both parameters, termed total lesion glycolysis (TLG); Methods: One-hundred-eight PET datasets (PET1, n = 54; PET2, n = 54) of 54 children were analysed by visual and semi-quantitative means. SUVmax, SUVmean, MTV and TLG were obtained the results of both PETs and the relative change from PET1 to PET2 (Δ in %) were compared for their capability of identifying responders and non-responders using receiver operating characteristics (ROC)-curves. In consideration of individual variations in noise and contrasts levels all parameters were additionally obtained after threshold correction to lean body mass and background; Results: All semi-quantitative SUV estimates obtained at PET2 were significantly superior to the visual PET2 analysis. However, ΔSUVmax revealed the best results (area under the curve, 0.92; p < 0.001; sensitivity 100%; specificity 85.4%; PPV 46.2%; NPV 100%; accuracy, 87.0%) but was not significantly superior to SUVmax-estimation at PET2 and ΔTLGmax. Likewise, the lean body mass and background individualization of the datasets did not impove the results of the ROC analyses; Conclusions: Sophisticated semi-quantitative PET measures in early response assessment of pHL patients do not perform significantly better than the previously proposed ΔSUVmax. All analytical strategies failed to improve the impaired PPV to a clinically acceptable level while preserving the excellent NPV.

  8. FDG-PET Response Prediction in Pediatric Hodgkin’s Lymphoma: Impact of Metabolically Defined Tumor Volumes and Individualized SUV Measurements on the Positive Predictive Value

    International Nuclear Information System (INIS)

    Hussien, Amr Elsayed M.; Furth, Christian; Schönberger, Stefan; Hundsdoerfer, Patrick; Steffen, Ingo G.; Amthauer, Holger; Müller, Hans-Wilhelm; Hautzel, Hubertus

    2015-01-01

    Background: In pediatric Hodgkin’s lymphoma (pHL) early response-to-therapy prediction is metabolically assessed by (18)F-FDG PET carrying an excellent negative predictive value (NPV) but an impaired positive predictive value (PPV). Aim of this study was to improve the PPV while keeping the optimal NPV. A comparison of different PET data analyses was performed applying individualized standardized uptake values (SUV), PET-derived metabolic tumor volume (MTV) and the product of both parameters, termed total lesion glycolysis (TLG); Methods: One-hundred-eight PET datasets (PET1, n = 54; PET2, n = 54) of 54 children were analysed by visual and semi-quantitative means. SUVmax, SUVmean, MTV and TLG were obtained the results of both PETs and the relative change from PET1 to PET2 (Δ in %) were compared for their capability of identifying responders and non-responders using receiver operating characteristics (ROC)-curves. In consideration of individual variations in noise and contrasts levels all parameters were additionally obtained after threshold correction to lean body mass and background; Results: All semi-quantitative SUV estimates obtained at PET2 were significantly superior to the visual PET2 analysis. However, ΔSUVmax revealed the best results (area under the curve, 0.92; p < 0.001; sensitivity 100%; specificity 85.4%; PPV 46.2%; NPV 100%; accuracy, 87.0%) but was not significantly superior to SUVmax-estimation at PET2 and ΔTLGmax. Likewise, the lean body mass and background individualization of the datasets did not impove the results of the ROC analyses; Conclusions: Sophisticated semi-quantitative PET measures in early response assessment of pHL patients do not perform significantly better than the previously proposed ΔSUVmax. All analytical strategies failed to improve the impaired PPV to a clinically acceptable level while preserving the excellent NPV

  9. Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.

    Science.gov (United States)

    Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu

    2017-09-01

    The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  10. The Value of High-Resolution MRI Technique in Patients with Rectal Carcinoma: Pre-Operative Assessment of Mesorectal Fascia Involvement, Circumferential Resection Margin and Local Staging

    International Nuclear Information System (INIS)

    Algebally, Ahmed Mohamed; Mohey, Nesreen; Szmigielski, Wojciech; Yousef, Reda Ramadan Hussein; Kohla, Samah

    2015-01-01

    The purpose of the study was to identify the accuracy of high-resolution MRI in the pre-operative assessment of mesorectal fascia involvement, circumfrential resection margin (CRM) and local staging in patients with rectal carcinoma. The study included 56 patients: 32 male and 24 female. All patients underwent high-resolution MRI and had confirmed histopathological diagnosis of rectal cancer located within 15 cm from the anal verge, followed by surgery. MRI findings were compared with pathological and surgical results. The overall accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MRI-based T-staging were 92.8, 88.8%, 96.5%, 96%, and 90.3%, respectively. The accuracy, sensitivity, specificity, PPV, and NPV of MRI-based assessment of CRM were 94.6%, 84.6%, 97.6%, 91.4, and 94.6%, respectively. The accuracy, sensitivity, specificity, PPV, and NPV of MRI-based N-staging were 82.1%, 75%, 67.3%, 60%, and 86.1%, respectively. Preoperative high-resolution rectal MRI is accurate in predicting tumor stage and CRM involvement. MRI is a precise diagnostic tool to select patients who may benefit from neo-adjuvant therapy and to avoid overtreatment in those patients who can proceed directly to surgery

  11. Sorption of Np(V) by synthetic hydroxyapatite

    International Nuclear Information System (INIS)

    Moore, R.C.; Holt, K.; Zhao, H.; Hasan, A.; Awwad, N.; Gasser, M.; Sanchez, C.

    2003-01-01

    The sorption of Np(V) to synthetic hydroxyapatite was determined in batch experiments in a 0.1 M NaClO 4 solution. The hydroxyapatite used was of high purity as determined by SEM, EDS, XRD, FT-IR and ICP-MS analysis. Results from kinetic experiments with an initial Np(V) concentration of 1 x 10 -7 to 1 x 10 -6 M indicate the sorption process is relatively fast with more than 90% of the Np(V) being sorbed in approximately 3 hours. Equilibrium experiments performed over the pH range of 6 to 11 indicated sorption is strongly pH dependent with distribution coefficients, K d values (mL/g), increasing from 123 L/mole at pH 6 to 69 200 L/mole at pH 8.5. K d values are observed to decrease as pH further increases. Data points over a range of Np(V) concentrations were collected at pH 8 and fitted to the Langmuir isotherm model for simple adsorption. The Langmuir equation gave an excellent representation of the data. Langmuir parameters were determined to be C a = 0.032 mole/mole and K = 1.22 x 10 6 L/mole, indicating the high affinity of hydroxyapatite for Np(V) adsorption. (orig.)

  12. NPV Sensitivity Analysis: A Dynamic Excel Approach

    Science.gov (United States)

    Mangiero, George A.; Kraten, Michael

    2017-01-01

    Financial analysts generally create static formulas for the computation of NPV. When they do so, however, it is not readily apparent how sensitive the value of NPV is to changes in multiple interdependent and interrelated variables. It is the aim of this paper to analyze this variability by employing a dynamic, visually graphic presentation using…

  13. Solubility studies of Np(V) in simulated underground water

    International Nuclear Information System (INIS)

    Zhang Yingjie; Ren Lilong; Jiao Haiyang; Yao Jun; Su Xiguang; Fan Xianhua

    2004-01-01

    The solubility of Np(V) in simulated underground water has been measured with the variation of pH, storage time (0-100 days). All experiments were performed in an Ar glove box which contained high purity Ar, with an oxygen content of less than 5ppm. Experimental results show that the solubility of Np(V) in simulated underground water decreased with increasing pH value of solution; the solubility of Np(V) in simulated underground water determined at different pH is : pH=6.96, [Np(V)]=(3.52±0.37) x 10 -4 mol/L; pH=8.04, [Np(V)]=(8.24±0.32) x 10 -5 mol/L; pH=9.01, [Np(V)]=(3.04±0.48) x 10'- 5 mol/L, respectively. (author)

  14. Early 18F-FDG-PET/CT as a predictive marker for treatment response and survival in patients with metastatic colorectal cancer treated with irinotecan and cetuximab

    DEFF Research Database (Denmark)

    Skougaard, K; Nielsen, Dorte; Vittrup Jensen, Benny

    2016-01-01

    to RECIST 1.0. Results: By EORTC criteria, early metabolic response predicted partial metabolic response (PMR) with a high positive predictive value (PPV) of 0.875 and a high negative predictive value (NPV) of 0.714. Partial radiologic response was predicted with a low PPV of 0.368 but a high NPV of 1.......0. By PERCIST, PMR was predicted with a high PPV of 0.826 and an intermediate NPV of 0.667 and partial radiologic response was predicted with a low PPV of 0.5 but a high NPV of 1.0. Median OS was nearly the same with the two criteria sets; 14.1 months for early metabolic responders and 9.9 months for non......-responders using EORTC criteria and 13.5 and 10.1 months, respectively, using PERCIST. Conclusions: With both EORTC criteria and PERCIST, early reduction in FDG uptake was predictive of a later partial metabolic and partial radiologic response to treatment. It was also predictive of significantly longer survival...

  15. Thermoluminescence and photoluminescence analyses of MEH-PPV, MDMO-PPV and RU(bpy)3 gamma-irradiated polymer thin films

    International Nuclear Information System (INIS)

    Ortiz-Morales, A.; Ortiz-Lopez, J.; Cruz-Zaragoza, E.; Gómez-Aguilar, R.

    2015-01-01

    Effects of irradiation with 60 Co gamma photons on poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV), poly[2-methoxy-5-(3′,7′ dimethyloctyloxy)-1,4-phenylenevinylene] (MDMO-PPV) and tris(2,2′-bipyridyl)dichlororuthenium(II) hexahydrate (Ru(bpy) 3 ) thin films were analyzed regarding their thermoluminescence (TL) and photoluminescence (PL) properties. A linear TL dose response was obtained from the MEH-PPV and MDMO-PPV polymer films in dose ranges of approximately 0.170–4.08 kGy and 0.170–0.850 kGy, respectively, followed by a supralinear behavior. A dependence on the conjugation length of the polymer chains which was favored by heating of the film, was observed, and irradiation generated a blue-shift in MEH-PPV and Ru(bpy) 3 . Furthermore, the PL structure was not modified. The most likely effect involved in the TL emission was trapping. The high activation energy values of the traps in the TL may be attributed in part to the binding energy of the exciton. A deconvolution process was carried out to obtain the kinetic parameters from the TL glow curves and PL spectra. - Highlights: • Irradiation effects on MEH-PPV, MDMO-PPV and Ru(bpy) 3 were analyzed by TL and PL. • The dose response of PPV derivatives was linear at higher doses (0.170–4.08 kGy). • Activation energy, was larger than 2 eV, suggest a possible good stability of traps. • PL spectra for non-irradiated and gamma irradiated polymer are almost identical

  16. Differentiating benign from malignant solid breast masses: value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification.

    Science.gov (United States)

    Evans, A; Whelehan, P; Thomson, K; Brauer, K; Jordan, L; Purdie, C; McLean, D; Baker, L; Vinnicombe, S; Thompson, A

    2012-07-10

    The aim of this study was to assess the performance of shear wave elastography combined with BI-RADS classification of greyscale ultrasound images for benign/malignant differentiation in a large group of patients. One hundred and seventy-five consecutive patients with solid breast masses on routine ultrasonography undergoing percutaneous biopsy had the greyscale findings classified according to the American College of Radiology BI-RADS. The mean elasticity values from four shear wave images were obtained. For mean elasticity vs greyscale BI-RADS, the performance results against histology were sensitivity: 95% vs 95%, specificity: 77% vs 69%, Positive Predictive Value (PPV): 88% vs 84%, Negative Predictive Value (NPV): 90% vs 91%, and accuracy: 89% vs 86% (all P>0.05). The results for the combination (positive result from either modality counted as malignant) were sensitivity 100%, specificity 61%, PPV 82%, NPV 100%, and accuracy 86%. The combination of BI-RADS greyscale and shear wave elastography yielded superior sensitivity to BI-RADS alone (P=0.03) or shear wave alone (P=0.03). The NPV was superior in combination compared with either alone (BI-RADS P=0.01 and shear wave P=0.02). Together, BI-RADS assessment of greyscale ultrasound images and shear wave ultrasound elastography are extremely sensitive for detection of malignancy.

  17. The Value of a Checklist for Child Abuse in Out-of-Hours Primary Care: To Screen or Not to Screen.

    Science.gov (United States)

    Schouten, Maartje Cm; van Stel, Henk F; Verheij, Theo Jm; Houben, Michiel L; Russel, Ingrid Mb; Nieuwenhuis, Edward Es; van de Putte, Elise M

    2017-01-01

    To assess the diagnostic value of the screening instrument SPUTOVAMO-R2 (checklist, 5 questions) for child abuse at Out-of-hours Primary Care locations (OPC), by comparing the test outcome with information from Child Protection Services (CPS). Secondary, to determine whether reducing the length of the checklist compromises diagnostic value. All children (abuse (32.8%). The positive predictive value (PPV) of the checklist for child abuse was 8.3 (95% CI 3.9-15.2). The negative predictive value (NPV) was 99.1 (98.8-99.3), with 52 false negatives. When the length of the checklist was reduced to two questions closely related to the medical process (SPUTOVAMO-R3), the PPV was 9.1 (3.7-17.8) and the NPV 99.1 (98.7-99.3). These two questions are on the injury in relation to the history, and the interaction between child and parents. The checklist SPUTOVAMO-R2 has a low detection rate of child abuse within the OPC setting, and a high false positive rate. Therefore, we recommend to use the shortened checklist only as a tool to increase the awareness of child abuse and not as a diagnostic instrument.

  18. Lumbar internal disc derangement in patients with chronic low back pain: diagnostic value of the MR imaging findings as compared with provoked discography as the standard

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyeon Seon; Park, Jee Young; Lee, Sang Ho; Ahn, Yong [Wooridul spine Hospital, Seoul (Korea, Republic of); Lee, Sang Yeun [Puchon Daesung Hospital, Puchon (Korea, Republic of)

    2006-04-15

    The aim of this study was to evaluate the diagnostic value of the MR imaging findings with provoked discography used as the standard for painful lumbar disc derangement. Two hundred patients (412 discs), (age rang: 21-77 year), with chronic low back pain underwent MRI and provoked discography. We evaluated the MRI T2-WI findings such as disc degeneration, high-Intensity zones and endplate abnormalities. Subsequently, provocative discography was independently performed with using MR imaging, and a painful disc was defined when moderate to severe and concordant pain was provoked. We calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the MRI findings with using provoked discography as the standard. 400 discs showed abnormal findings such as disc degeneration, HIZ and endplate abnormalities on the T2-WI images. 12 discs showed normal finding. HIZ or endplate abnormalities were always combined with disc degeneration. The prevalence of each findings were disc degeneration (400 discs: 97.1%), HIZ (111 discs: 26.9%), type I endplate abnormalities (34 discs: 8.3%), type II endplate abnormalities (75 discs: 18.2%), the combined findings of HIZ and type I endplate abnormalities (2 discs: 0.5%) and the combined findings of HIZ and type II endplate abnormalities (7 discs: 1.7%). The disc degeneration showed high sensitivity (99.5%) and low specificity (5.0%), so only the NPV (91.7%) was significant, and not the PPV (47.8%). Each findings of HIZ (sensitivity, 36.5%, specificity, 81.4%; PPV, 63.18%; NPV, 59.5%), type I endplate abnormalities (11.0%, 94.1%, 61.8% and 54.8%, respectively), type II endplate abnormalities (19.8%, 83.2%, 50.7% and 54.3%, respectively), the combined findings of HIZ and type I endplate abnormalities (0.5%, 99.6%, 50.0% and 53.4%, respectively) and the combined findings of HIZ and type II endplate abnormalities (26.0%, 99.1%, 71.4% and 53.8%, respectively) show high specificity, but low

  19. Lumbar internal disc derangement in patients with chronic low back pain: diagnostic value of the MR imaging findings as compared with provoked discography as the standard

    International Nuclear Information System (INIS)

    Park, Hyeon Seon; Park, Jee Young; Lee, Sang Ho; Ahn, Yong; Lee, Sang Yeun

    2006-01-01

    The aim of this study was to evaluate the diagnostic value of the MR imaging findings with provoked discography used as the standard for painful lumbar disc derangement. Two hundred patients (412 discs), (age rang: 21-77 year), with chronic low back pain underwent MRI and provoked discography. We evaluated the MRI T2-WI findings such as disc degeneration, high-Intensity zones and endplate abnormalities. Subsequently, provocative discography was independently performed with using MR imaging, and a painful disc was defined when moderate to severe and concordant pain was provoked. We calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the MRI findings with using provoked discography as the standard. 400 discs showed abnormal findings such as disc degeneration, HIZ and endplate abnormalities on the T2-WI images. 12 discs showed normal finding. HIZ or endplate abnormalities were always combined with disc degeneration. The prevalence of each findings were disc degeneration (400 discs: 97.1%), HIZ (111 discs: 26.9%), type I endplate abnormalities (34 discs: 8.3%), type II endplate abnormalities (75 discs: 18.2%), the combined findings of HIZ and type I endplate abnormalities (2 discs: 0.5%) and the combined findings of HIZ and type II endplate abnormalities (7 discs: 1.7%). The disc degeneration showed high sensitivity (99.5%) and low specificity (5.0%), so only the NPV (91.7%) was significant, and not the PPV (47.8%). Each findings of HIZ (sensitivity, 36.5%, specificity, 81.4%; PPV, 63.18%; NPV, 59.5%), type I endplate abnormalities (11.0%, 94.1%, 61.8% and 54.8%, respectively), type II endplate abnormalities (19.8%, 83.2%, 50.7% and 54.3%, respectively), the combined findings of HIZ and type I endplate abnormalities (0.5%, 99.6%, 50.0% and 53.4%, respectively) and the combined findings of HIZ and type II endplate abnormalities (26.0%, 99.1%, 71.4% and 53.8%, respectively) show high specificity, but low

  20. Predictive value of brain SPECT with 99 technetium - MIBI for differentiation of histologic grade brain gliomas

    International Nuclear Information System (INIS)

    León Castellón, Roberto; Martín Escuela, Juan Miguel; López Díaz, Ing. Adlin; Salva Camaño, Silvia; Gómez Viera, DrC. Nelson; San Pedro, Aley Palau; Castro Jiménez, Mayté

    2016-01-01

    Diagnosis and treatment of primary tumors of the nervous system remain difficult and are a challenge to be addressed in a multidisciplinary way. In order to determine the usefulness of brain SPECT 99 Tc MIBI to differentiate histologic grade brain gliomas - Frequently brain tumors - they were studied 68 patients with this technique. A dynamic study first step in AP and lateral view was performed, and a SPECT at 20 minutes post-administration and at 2 hours late views. the post-surgical histological study of injuries was used as control. several imaging parameters such as the absolute activity of 99m Tc-MIBI were calculated both early and late phase, cortex contralateral tumor rates; pituitary tumor; choroid plexus tumor and Reason Late / Early phase tumor index / contralateral cortex tumor volume functional phase, the volume concentration of MIBI activity in the tumor and the retention rate of the radiopharmaceutical. Of the 68 patients studied, 11 were high-grade tumors and 57 low grade. The cortex contralateral tumor in late stage index showed a negative satisfactory sensitivity of 98.6% and specificity 77.1%, positive predictive value (PPV) of 48.2% and (NPV) of 99.8%. The reason late stage / early in the index tumor / contralateral cortex showed values ​​in turn 96.3%, 98.7%, 98.8% and 98.8% sensitivity, specificity, PPV and NPV respectively. The retention rate showed a 99% sensitivity, 89% specificity and PPV, NPV of 95% and 99% respectively. Conclusion: The combination cortex contralateral tumor rate in late stage, the reason late stage / early stage tumor index / contralateral cortex and the retention rate of the radiopharmaceutical are the most useful parameters to predict histologic grade of brain gliomas. (author)

  1. Magnetic resonance imaging in local staging of endometrial carcinoma: diagnostic performance, pitfalls, and literature review.

    Science.gov (United States)

    Zandrino, Franco; La Paglia, Ernesto; Musante, Francesco

    2010-01-01

    To assess the diagnostic accuracy of magnetic resonance imaging in local staging of endometrial carcinoma, and to review the results and pitfalls described in the literature. Thirty women with a histological diagnosis of endometrial carcinoma underwent magnetic resonance imaging. Unenhanced T2-weighted and dynamic contrast-enhanced Ti-weighted sequences were obtained. Hysterectomy and salpingo-oophorectomy was performed in all patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the detection of deep myometrial and cervical infiltration. For deep myometrial infiltration T2-weighted sequences reached a sensitivity of 85%, specificity of 76%, PPV of 73%, NVP of 87%, and accuracy of 80%, while contrast-enhanced scans reached a sensitivity of 90%, specificity of 80%, PPV of 82%, NPV of 89%, and accuracy of 85%. For cervical infiltration T2-weighted sequences reached a sensitivity of 75%, specificity of 88%, PPV of 50%, NPV of 96%, and accuracy of 87%, while contrast-enhanced scans reached a sensitivity of 100%, specificity of 94%, PPV of 75%, NPV of 100%, and accuracy of 95%. Unenhanced and dynamic gadolinium-enhanced magnetic resonance allows accurate assessment of myometrial and cervical infiltration. Information provided by magnetic resonance imaging can define prognosis and management.

  2. Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

    International Nuclear Information System (INIS)

    Zhang, Jian Jun; Liu, Tie; Feng, Yue; Wu, Wei Feng; Mou, Cai Yun; Zhai, Li Hao

    2011-01-01

    We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses (≥ 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen's Kappa statistics were calculated for the intermodality and interobserver agreement. The mean heart rate was 89 ± 8.3 bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen's Kappa statistics demonstrated good intermodality and interobserver agreement. 64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.

  3. Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian Jun; Liu, Tie; Feng, Yue; Wu, Wei Feng; Mou, Cai Yun; Zhai, Li Hao [Zhejiang Hospital, Hangzhou (China)

    2011-08-15

    We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses ({>=} 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen's Kappa statistics were calculated for the intermodality and interobserver agreement. The mean heart rate was 89 {+-} 8.3 bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen's Kappa statistics demonstrated good intermodality and interobserver agreement. 64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.

  4. Application value of different transformation zone types and its genetic relationship with high-risk HPV type in diagnosis and therapy of cervical disease.

    Science.gov (United States)

    Chen, Yan; Zhou, Jia-De

    2015-01-01

    This study aims to discuss the influence of different types of transformation zone (TZ) on positive surgical margin of loop electrosurgical excision procedure (LEEP) and the significance of infection of different genetic high-risk HPV for cervical intraepithelial neoplasm. The clinical data of patients who had CIN2+ and received LEEP during January to December 2013 was investigated. The conditions of positive surgical margin of patients of different transformation zone (type I, II, III) were analyzed. The clinical high-risk types of HPV were divided into three groups, including A5/6, A7 and A9, compared with the pathological conditions of pre-operation and post-operation of the patients in respective group. The results indicated that type III transformation zone is more likely to cause positive cutting margin. For CIN2+ patients, sensitivity and specificity are 0.89% and 79.56% in group A5/6, and negative and positive predicted value (NPV, PPV) are 40% and 5%. The sensitivity, specificity, NPV, PPV in group A7 is 12.5%, 44.08%, 29.49% and 21.21%, respectively. The sensitivity, specificity, NPV, PPV in group A9 is 88.99%, 87.09%, 85.26%, 81.51%, respectively. Transformation zone type was correlated positively with positive cutting margin percentage (r = 0.8732, P zone is more likely to cause pathological upgrades. In conclusion, different types of transformation zone and high-risk HPV have clinical significance in causing positive cutting margin of surgery and disease extent.

  5. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  6. Complex chemistry of Np(V) in aqueous solutions

    International Nuclear Information System (INIS)

    Inoue, Yasushi

    1989-01-01

    Despite the importance of Np(V) in both the nuclear chemical engineering and the actinoid chemistry, little work has been performed on the complex chemistry of Np(V) in aqueous solutions, since Np(V) reacts less readily with various ligands. The author has directed his effort to understand the chemical behavior of Np(V) in aqueous solutions, especially the determination of the stability constants of Np(V) complexes with various ligands. A part of the results obtained so far is presented in the following order. (1) The synergistic extraction of Np(V) as a method for studying the complex chemistry of Np(V): TTA-MTOA(methyltrioctylammonium chloride), TTA-phen and TTA-TOPO. (2) The determination of the stability constants of Np(V) complexes with 22 organic- and 5 inorganic ligands by means of the solvent extraction. (3) The distribution of the chemical species of Np(V) in solutions under various conditions

  7. Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection

    Energy Technology Data Exchange (ETDEWEB)

    Borens, Bruno [Polyclinique Santa Maria, Nice (France); Arvanitakis, Marianna; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques [Erasme Hospital, Department of Gastroenterology, Brussels (Belgium); Absil, Julie; Matos, Celso; Bali, Maria Antonietta [Erasme Hospital, Department of Radiology, Brussels (Belgium); El Bouchaibi, Said [Epicura, Ath (Belgium)

    2017-03-15

    To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC). Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm{sup 2}) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance. For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P >.05). ADC were lower in infected versus non-infected PFCs (P ≤.031). Minimum ADC cut-off: 1,090 x 10{sup -3} mm{sup 2}/s for reader 1 and 1,012 x 10{sup -3} mm{sup 2}/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers). Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. (orig.)

  8. Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection

    International Nuclear Information System (INIS)

    Borens, Bruno; Arvanitakis, Marianna; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques; Absil, Julie; Matos, Celso; Bali, Maria Antonietta; El Bouchaibi, Said

    2017-01-01

    To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC). Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm"2) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance. For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P >.05). ADC were lower in infected versus non-infected PFCs (P ≤.031). Minimum ADC cut-off: 1,090 x 10"-"3 mm"2/s for reader 1 and 1,012 x 10"-"3 mm"2/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers). Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. (orig.)

  9. Langmuir-Blodgett film based on MEH-PPV for cholesterol biosensor

    International Nuclear Information System (INIS)

    Matharu, Zimple; Arya, Sunil K.; Singh, S.P.; Gupta, Vinay; Malhotra, B.D.

    2009-01-01

    Cholesterol oxidase (ChOx) has been immobilized onto conducting poly[2-methoxy,5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV)/stearic acid (SA) Langmuir-Blodgett film transferred onto octadecanethiol (ODT) modified gold plate. The ChOx/MEH-PPV/SA LB film bioelectrode exhibits has been characterized by FT-IR, contact angle, and atomic force microscopy. The response of the ChOx/MEH-PPV/SA LB film bioelectrode carried out using differential pulse voltammetry (DPV) studies reveal linearity from 1.29 to 12.91 mM of cholesterol concentration and response time as 30 s. This ChOx/MEH-PPV/SA bioelectrode exhibits values of correlation coefficient as 0.9939, standard deviation as 0.0029 μA and limit of detection as 1.66 mM. UV-visible spectrophotometer studies reveal that 5.2 x 10 -3 U of ChOx are actively working per cm 2 area of ChOx/MEH-PPV/SA LB film bioelectrode and this bioelectrode is thermally stable upto 55 deg. C with reusability of about 60 times

  10. Langmuir-Blodgett film based on MEH-PPV for cholesterol biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Matharu, Zimple [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Arya, Sunil K.; Singh, S.P. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Gupta, Vinay [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Malhotra, B.D. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India)], E-mail: bansi.malhotra@gmail.com

    2009-02-23

    Cholesterol oxidase (ChOx) has been immobilized onto conducting poly[2-methoxy,5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV)/stearic acid (SA) Langmuir-Blodgett film transferred onto octadecanethiol (ODT) modified gold plate. The ChOx/MEH-PPV/SA LB film bioelectrode exhibits has been characterized by FT-IR, contact angle, and atomic force microscopy. The response of the ChOx/MEH-PPV/SA LB film bioelectrode carried out using differential pulse voltammetry (DPV) studies reveal linearity from 1.29 to 12.91 mM of cholesterol concentration and response time as 30 s. This ChOx/MEH-PPV/SA bioelectrode exhibits values of correlation coefficient as 0.9939, standard deviation as 0.0029 {mu}A and limit of detection as 1.66 mM. UV-visible spectrophotometer studies reveal that 5.2 x 10{sup -3} U of ChOx are actively working per cm{sup 2} area of ChOx/MEH-PPV/SA LB film bioelectrode and this bioelectrode is thermally stable upto 55 deg. C with reusability of about 60 times.

  11. Predictive values of BI-RADS® magnetic resonance imaging (MRI) in the detection of breast ductal carcinoma in situ (DCIS)

    International Nuclear Information System (INIS)

    Badan, Gustavo Machado; Piato, Sebastião; Roveda, Décio; Faria Castro Fleury, Eduardo de

    2016-01-01

    Purpose: The purpose of this study was to evaluate BI-RADS indicators in the detection of DCIS by MRI. Materials and methods: Prospective observational study that started in 2014 and lasted 24 months. A total of 110 consecutive patients were evaluated, who presented with suspicious or highly suspicious microcalcifications on screening mammography (BI-RADS categories 4 and 5) and underwent stereotactic-guided breast biopsy, having had an MRI scan performed prior to biopsy. Results: Altogether, 38 cases were characterized as positive for malignancy, of which 25 were DCIS and 13 were invasive ductal carcinoma cases. MRI had a sensitivity of 96%; specificity of 75.67%; positive predictive value (PPV) for DCIS detection of 57.14%; negative predictive value (NPV) in the detection of DCIS of 98.24%; and an accuracy of 80.80%. Conclusion: BI-RADS as a tool for the detection of DCIS by MRI is a powerful instrument whose sensitivity was higher when compared to that observed for mammography in the literature. Likewise, the PPV obtained by MRI was higher than that observed in the present study for mammography, and the high NPV obtained on MRI scans can provide early evidence to discourage breast biopsy in selected cases.

  12. Value of digital radiography in expiration in detection of pneumothorax

    International Nuclear Information System (INIS)

    Thomsen, L.; Natho, O.; Feigen, U.; Kivelitz, D.; Schulz, U.

    2014-01-01

    Purpose: The purpose of this study was to find out whether pneumothorax detection and exclusion is superior in expiratory digital chest radiography. Materials and Methods: 131 patients with pneumothorax with paired inspiratory and expiratory chest radiographs were analyzed regarding localization and size of pneumothorax. Sensitivity, specificity, negative (npv) and positive predictive value (ppv) as well as the positive (LR+) and negative likelihood ratio (LR-) were determined in a blinded randomized interobserver study with 116 patients. The evaluation was performed by three board-certified radiologists. Results: In 131 patients, there were 139 pneumothoraces, 135 (97.1 %) were located apical, 88 (63.3 %) lateral and 33 (23.7 %) basal. Sensitivity was 99 % for inspiratory and 97 % for expiratory radiographs. The interobserver study yielded a mean sensitivity of 86.1 %/86.1 %, specificity of 97.3 %/93.4 %, npv of 88.7 %/88.5 % and ppv of 96.7 %/92.1 % for inspiration/expiration. For inspiratory radiographs the LR+/LR- were 40.2/0.14 and for expiration 13.9 and 0.15. McNemar-Test showed no significant difference for the detection of pneumothoraces in in-/exspiration. Conclusion: Inspiratory and expiratory digital radiographs are equally suitable for pneumothorax detection. Inspiratory radiographs are recommended as the initial examination of choice for pneumothorax detection, an additional expiratory radiograph is only recommended in doubtful cases. (orig.)

  13. Predictive values of BI-RADS{sup ®} magnetic resonance imaging (MRI) in the detection of breast ductal carcinoma in situ (DCIS)

    Energy Technology Data Exchange (ETDEWEB)

    Badan, Gustavo Machado, E-mail: gustavobadan@hotmail.com [Breast Imaging Service of Radiology Depatment—Irmandade da Santa Casa de Misericórdia de São Paulo, São Paulo, SP (Brazil); Piato, Sebastião [Mastology Division—Gynecology and Obstetrics Department (Brazil); Roveda, Décio; Faria Castro Fleury, Eduardo de [Breast Imaging Service of Radiology Depatment—Irmandade da Santa Casa de Misericórdia de São Paulo, São Paulo, SP (Brazil)

    2016-10-15

    Purpose: The purpose of this study was to evaluate BI-RADS indicators in the detection of DCIS by MRI. Materials and methods: Prospective observational study that started in 2014 and lasted 24 months. A total of 110 consecutive patients were evaluated, who presented with suspicious or highly suspicious microcalcifications on screening mammography (BI-RADS categories 4 and 5) and underwent stereotactic-guided breast biopsy, having had an MRI scan performed prior to biopsy. Results: Altogether, 38 cases were characterized as positive for malignancy, of which 25 were DCIS and 13 were invasive ductal carcinoma cases. MRI had a sensitivity of 96%; specificity of 75.67%; positive predictive value (PPV) for DCIS detection of 57.14%; negative predictive value (NPV) in the detection of DCIS of 98.24%; and an accuracy of 80.80%. Conclusion: BI-RADS as a tool for the detection of DCIS by MRI is a powerful instrument whose sensitivity was higher when compared to that observed for mammography in the literature. Likewise, the PPV obtained by MRI was higher than that observed in the present study for mammography, and the high NPV obtained on MRI scans can provide early evidence to discourage breast biopsy in selected cases.

  14. Duplex criteria for determination of in-stent stenosis after angioplasty and stenting of the superficial femoral artery.

    Science.gov (United States)

    Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K

    2009-01-01

    Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.

  15. [Application of a continual improvement approach to selecting diagnostic markers for acute pancreatitis in an emergency department].

    Science.gov (United States)

    Salinas, María; Flores, Emilio; López-Garrigós, Maite; Díaz, Elena; Esteban, Patricia; Leiva-Salinas, Carlos

    2017-01-01

    To apply a continual improvement model to develop an algorithm for ordering laboratory tests to diagnose acute pancreatitis in a hospital emergency department. Quasi-experimental study using the continual improvement model (plan, do, check, adjust cycles) in 2 consecutive phases in emergency patients: amylase and lipase results were used to diagnose acute pancreatitis in the first phase; in the second, only lipase level was first determined; amylase testing was then ordered only if the lipase level fell within a certain range. We collected demographic data, number amylase and lipase tests ordered and the findings, final diagnosis, and the results of a questionnaire to evaluate satisfaction with emergency care. The first phase included 517 patients, of whom 20 had acute pancreatitis. For amylase testing sensitivity was 0.70; specificity, 0.85; positive predictive value (PPV), 17; and negative predictive value (NPV), 0.31. For lipase testing these values were sensitivity, 0.85; specificity, 0.96; PPV, 21, and NPV, 0.16. When both tests were done, sensitivity was 0.85; specificity 0.99; PPV, 85; and NPV, 0.15. The second phase included data for 4815 patients, 118 of whom had acute pancreatitis. The measures of diagnostic yield for the new algorithm were sensitivity, 0.92; specificity, 0.98; PPV, 46; and NPV, 0.08]. This study demonstrates a process for developing a protocol to guide laboratory testing in acute pancreatitis in the hospital emergency department. The proposed sequence of testing for pancreatic enzyme levels can be effective for diagnosing acute pancreatitis in patients with abdominal pain.

  16. Direct MR Arthrography of the wrist in comparison with Arthroscopy: A prospective study on 125 patients

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Coblenz, G.; Froehner, S.; Meier, R.; Lanz, U.; Krimmer, H.

    2003-01-01

    Objective: In literature the diagnostic value of MRI for detecting lesions of the carpal ligaments and the TFCC is judged controversially. The aim of the following study is to determine the diagnostic accuracy of direct MR arthrography for depicting and staging of intraarticular lesions of the wrist. Material and methods: One day before undergoing arthroscopy, 125 patients suffering from wrist pain were examined with direct MR arthrography in a prospective and blinded study. A mixture of contrast medium (iodine-containing contrast medium and gadopentetate in relation 200:1) was injected into both radiocarpal and midcarpal joints. The following sequences were acquired on a 1.5T scanner: coronal T1-weighted SE, coronal fat-saturated T1-weighted SE, coronal T1-/T2*-DESS-3D, and sagittal T2*-weighted MEDIC. MRI results were compared with arthroscopic findings using statistical analysis (SEN=sensitivity, SPE=specificity, PPV=positive predictive value, NPV=negative predictive value, ACC=accuracy). Results: In comparison to arthroscopy as the accepted diagnostic gold standard, the following results were found for MR arthrography. Detection of TFCC lesions: SEN 97.1%, SPE 96.4%, PPV 97.1%, NPV 96.4%, ACC 96.8%. Detection of complete tears of the scapholunate ligament: SEN 91.7%, SPE 100%, PPV 100%, NPV 99.1%, ACC 99.2%. Detection of partial tears: SEN 62.5%, SPE 100%, PPV 100%, NPV 94.8%, ACC 95.2%. Detection of cartilage defects: SEN 84.2%, SPE 96.2%, PPV 80%, NPV 97.1%, ACC 94.4%. In total, only three lesions of the lunotriquetral ligament were present. Conclusion: Direct MR arthrographic imaging is well suited for detecting intraarticular lesions of the wrist. The presented diagnostic results of MR arthrography are superior to the results of unenhanced MRI reported in the literature. Direct MR arthrography as a reliable diagnostic tool is strongly recommended if lesions of the scapholunate ligament and the triangular fibrocartilage complex are suspected. In contrast, an

  17. Genome sequence of Chinese porcine parvovirus strain PPV2010.

    Science.gov (United States)

    Cui, Jin; Wang, Xin; Ren, Yudong; Cui, Shangjin; Li, Guangxing; Ren, Xiaofeng

    2012-02-01

    Porcine parvovirus (PPV) isolate PPV2010 has recently emerged in China. Herein, we analyze the complete genome sequence of PPV2010. Our results indicate that the genome of PPV2010 bears mixed characteristics of virulent PPV and vaccine strains. Importantly, PPV2010 has the potential to be a naturally attenuated candidate vaccine strain.

  18. Genome Sequence of Chinese Porcine Parvovirus Strain PPV2010

    OpenAIRE

    Cui, Jin; Wang, Xin; Ren, Yudong; Cui, Shangjin; Li, Guangxing; Ren, Xiaofeng

    2012-01-01

    Porcine parvovirus (PPV) isolate PPV2010 has recently emerged in China. Herein, we analyze the complete genome sequence of PPV2010. Our results indicate that the genome of PPV2010 bears mixed characteristics of virulent PPV and vaccine strains. Importantly, PPV2010 has the potential to be a naturally attenuated candidate vaccine strain.

  19. Direct MR Arthrography of the wrist in comparison with Arthroscopy: A prospective study on 125 patients; Direkte MR-Arthrographie des Handgelenks im Vergleich zur Arthroskopie: Eine prospektive Studie an 125 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R.; Christopoulos, G.; Coblenz, G.; Froehner, S. [Institut fuer Diagnostische und Interventionelle Radiologie der Herz- und Gefaessklinik GmbH, Bad Neustadt an der Saale (Germany); Meier, R.; Lanz, U.; Krimmer, H. [Klinik fuer Handchirurgie GmbH, Bad Neustadt an der Saale (Germany)

    2003-07-01

    Objective: In literature the diagnostic value of MRI for detecting lesions of the carpal ligaments and the TFCC is judged controversially. The aim of the following study is to determine the diagnostic accuracy of direct MR arthrography for depicting and staging of intraarticular lesions of the wrist. Material and methods: One day before undergoing arthroscopy, 125 patients suffering from wrist pain were examined with direct MR arthrography in a prospective and blinded study. A mixture of contrast medium (iodine-containing contrast medium and gadopentetate in relation 200:1) was injected into both radiocarpal and midcarpal joints. The following sequences were acquired on a 1.5T scanner: coronal T1-weighted SE, coronal fat-saturated T1-weighted SE, coronal T1-/T2*-DESS-3D, and sagittal T2*-weighted MEDIC. MRI results were compared with arthroscopic findings using statistical analysis (SEN=sensitivity, SPE=specificity, PPV=positive predictive value, NPV=negative predictive value, ACC=accuracy). Results: In comparison to arthroscopy as the accepted diagnostic gold standard, the following results were found for MR arthrography. Detection of TFCC lesions: SEN 97.1%, SPE 96.4%, PPV 97.1%, NPV 96.4%, ACC 96.8%. Detection of complete tears of the scapholunate ligament: SEN 91.7%, SPE 100%, PPV 100%, NPV 99.1%, ACC 99.2%. Detection of partial tears: SEN 62.5%, SPE 100%, PPV 100%, NPV 94.8%, ACC 95.2%. Detection of cartilage defects: SEN 84.2%, SPE 96.2%, PPV 80%, NPV 97.1%, ACC 94.4%. In total, only three lesions of the lunotriquetral ligament were present. Conclusion: Direct MR arthrographic imaging is well suited for detecting intraarticular lesions of the wrist. The presented diagnostic results of MR arthrography are superior to the results of unenhanced MRI reported in the literature. Direct MR arthrography as a reliable diagnostic tool is strongly recommended if lesions of the scapholunate ligament and the triangular fibrocartilage complex are suspected. In contrast, an

  20. The diagnostic utility of the PSA screening test in a Ghanaian population

    International Nuclear Information System (INIS)

    Gyamfi, O.K.; Aryeetey, D.G.; Achel, D.G.; Gyasi, R. K.

    2004-01-01

    An immunoradiometric (IRMA) protocol was used in the PSA test to measure PSA levels in the sera of 240 men presenting with various complaints bordering on their prostate condition. These men were also made to undergo a fine-needle biopsy. Using the universal cut-off of 4.0ng/ml and the histopathological findings from the biopsies as a 'gold standard' statistical performance criteria (such as Sensitivity, Specificity, False Positive Ratio (FP), False Negative Ratio (FN), Likelihood Ratio (L), Positive Predictive Value (PPV), Negative Predictive Value (NPV), Prior Odds Ratio (Ω and Prevalence) were determined and compared with available literature values. This was to determine the diagnostic efficiency and utility of the PSA test for our Ghanaian population of 240 men. The test returned a Sensitivity and Specificity of 92.9% and 18.6% respectively. The FP and FN ratios were 81.4% and 7.1% respectively. The PPV and NPV were 38.1% and 82.9% respectively while the Prior Odds and Prevalence were 7:13 and 35% respectively. High sensitivities ranging from 79-90% and as low as 34 % have been reported. On the other hand specificities ranging from 59% to 70% have also been reported. The PPV compares favourably with the available literature values to us: within range 28-40%. The PPV and NPV values together with an application of Baye's theorem indicates that in our setting the PSA test is more efficient in ruling out disease than in detecting it. (au)

  1. The diagnostic value of [18F]FDG PET for the detection of chronic osteomyelitis and implant-associated infection

    International Nuclear Information System (INIS)

    Wenter, Vera; Albert, Nathalie L.; Lehner, Sebastian; Fendler, Wolfgang P.; Bartenstein, Peter; Mueller, Jan-Phillip; Friederichs, Jan; Militz, Matthias; Hungerer, Sven; Cyran, Clemens C.; Hacker, Marcus

    2016-01-01

    The diagnosis of osteomyelitis and implant-associated infections in patients with nonspecific laboratory or radiological findings is often unsatisfactory. We retrospectively evaluated the contributions of [ 18 F]FDG PET and [ 18 F]FDG PET/CT to the diagnosis of osteomyelitis and implant-associated infections, enabling timely and appropriate decision-making for further therapy options. [ 18 F]FDG PET or PET/CT was performed in 215 patients with suspected osteomyelitis or implant-associated infections between 2000 and 2013. We assessed the diagnostic accuracy of both modalities together and separately with reference to intraoperative microbial findings, with a mean clinical follow-up of 69 ± 49 months. Infections were diagnosed clinically in 101 of the 215 patients. PET and PET/CT scans revealed 87 true-positive, 76 true-negative, 38 false-positive, and 14 false-negative results, indicating a sensitivity of 86 %, a specificity of 67 %, a positive predictive value (PPV) of 70 %, a negative predictive value (NPV) of 84 % and an accuracy of 76 %. The sensitivity of PET/CT was 88 %, but specificity, PPV, NPV and accuracy (76 %, 76 %, 89 % and 82 %, respectively) were higher than those of stand-alone PET. [ 18 F]FDG PET is able to identify with high sensitivity the presence of osteomyelitis in orthopaedic surgery patients with nonspecific clinical symptoms of infection. (orig.)

  2. Value of magnetic resonance imaging in prenatal diagnosis of placental accretism

    International Nuclear Information System (INIS)

    Francisco, Viviane Vieira; Goldman, Suzan Menasce; Faria, Juliano; Szejnfeld, Jacob

    2006-01-01

    Purpose: to establish the main signs of placental accretism in magnetic resonance imaging (MRI) in patients with clinical suspicion and to estimate the benefit of this method. Methods: prospective transversal study with 15 patients suspected of placental accretism, referred between March 2003 and February 2006. Gestational age varied from 20 to 31 weeks. All patients underwent MRI to study the placenta and had previously done an ultrasonography. Material was sent to histological study. MRI was done on Magnetom Impact and Sonata Maestro Class Siemens R , with acquired sequences HASTE, TURBO SPIN in axial, sagittal, coronal planes and echo gradient (GE R ), pre- and post-dynamic contrast in the best plan for acquisition. Images were analyzed by a team of two radiologists. Results: mean gestational age was 24.3 weeks. We studied seven placenta previa (47%), six anterior placentas (40%) and two posterior placentas (13%). Ultrasonography was positive in 80% of the placentas and MRI in 53%. However, echography had a low concordance with anatomic pathological studies by Kappa test (11%), revealing 75% of sensitivity, 14% of specificity, 50% as positive predictive value (PPV) and 33% as negative predictive value (NPV). MRI had an excellent concordance with anatomic pathological studies (0.86), showing 100% of sensitivity, 86% of specificity, 89% as PPV and 100% as NPV. Conclusions: MRI is useful for placental accretism diagnosis. The principal findings are transmural hyper-signal, the loss of continuity in myometrial wall in fast sequences and the identification of vessels invading myometrial layer in dynamic sequences. (author)

  3. Magnetic Resonance Imaging Currently Fails to Fully Evaluate the Biceps-Labrum Complex and Bicipital Tunnel.

    Science.gov (United States)

    Taylor, Samuel A; Newman, Ashley M; Nguyen, Joseph; Fabricant, Peter D; Baret, Nikolas J; Shorey, Mary; Ramkumar, Prem; O'Brien, Stephen J

    2016-02-01

    To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for biceps-labrum complex (BLC) lesions, including the extra-articular bicipital tunnel. A retrospective review of 277 shoulders with chronic refractory BLC symptoms that underwent arthroscopic subdeltoid transfer of the long head of the biceps tendon (LHBT) to the conjoint tendon was conducted. Intraoperative lesions were categorized as "inside" (labral tears and dynamic LHBT incarceration), "junctional" (LHBT partial tears, LHBT subluxation, and biceps chondromalacia), or "bicipital tunnel" (extra-articular bicipital tunnel scar/stenosis, loose bodies, LHBT instability, and LHBT partial tears) based on anatomic location. Attending radiologist-generated MRI reports were graded dichotomously as positive or negative for biceps and labral damage and then compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for MRI with respect to intraoperative findings. With regard to inside lesions, MRI had an overall sensitivity, specificity, PPV, and NPV for labrum lesions of 77.3%, 68.2%, 57.3%, and 84.5% respectively. The sensitivity, specificity, PPV, and NPV of MRI for junctional lesions were 43.3%, 55.6%, 73.1%, and 26.0%, respectively. For the bicipital tunnel, MRI had a sensitivity, specificity, PPV, and NPV of 50.4%, 61.4%, 48.7%, and 63.0%, respectively. MRI was unreliable for ruling out BLC lesions among chronically symptomatic patients, including when the bicipital tunnel was affected. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. The role of N-terminal PRO-brain natriuretic peptide and echocardiography for screening asymptomatic left ventricular dysfunction in a population at high risk for heart failure. The PROBE-HF study.

    Science.gov (United States)

    Betti, Irene; Castelli, Gabriele; Barchielli, Alessandro; Beligni, Cinzia; Boscherini, Vittorio; De Luca, Leonardo; Messeri, Gianni; Gheorghiade, Mihai; Maisel, Alan; Zuppiroli, Alfredo

    2009-06-01

    Screening for asymptomatic left ventricular dysfunction (ALVD) in subjects at risk for heart failure (HF) can affect clinical management. The aim of the present study is to examine the role of NT-pro BNP in the diagnosis of ALVD in subjects with hypertension and diabetes from primary care. A total of 1012 subjects with hypertension and/or diabetes and no symptoms or signs of HF were assessed by B-type natriuretic peptide (NT-proBNP) assay and echocardiography. Diastolic dysfunction was present in 368/1012 subjects (36.4%): 327 (32.4%) with mild diastolic dysfunction and 41 (4%) with a moderate-to-severe diastolic dysfunction. Systolic dysfunction was present in 11/1012 (1.1%). NT-proBNP levels were 170 +/- 206 and 859 +/- 661 pg/mL, respectively, in diastolic and systolic dysfunction and 92 +/- 169 in normal subjects (P value of NT-proBNP was 125 pg/mL (males value [NPV] 99.5%, positive predictive value [PPV] 33.3%; females or=67 years: Sens 100%, Spec 77.1%, NPV 100%, PPV 32.5%; females >or=67 years: Sens 100%, Spec 59.9%, NPV 100%, PPV 23%). The prevalence of ALVD in subjects at risk for HF is 5.1%. Because of its excellent NPV, NT-proBNP can be used by general practitioners to rule out ALVD in hypertensive or diabetic patients.

  5. The diagnostic value of [{sup 18}F]FDG PET for the detection of chronic osteomyelitis and implant-associated infection

    Energy Technology Data Exchange (ETDEWEB)

    Wenter, Vera; Albert, Nathalie L.; Lehner, Sebastian; Fendler, Wolfgang P.; Bartenstein, Peter [University of Munich, Department of Nuclear Medicine, Munich (Germany); Mueller, Jan-Phillip; Friederichs, Jan; Militz, Matthias; Hungerer, Sven [BG Trauma Center Murnau, Murnau (Germany); PMU Salzburg, Salzburg (Austria); Cyran, Clemens C. [University of Munich, Institute for Clinical Radiology, Munich (Germany); Hacker, Marcus [University of Vienna, Department of Nuclear Medicine, Vienna (Austria); Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2016-04-15

    The diagnosis of osteomyelitis and implant-associated infections in patients with nonspecific laboratory or radiological findings is often unsatisfactory. We retrospectively evaluated the contributions of [{sup 18}F]FDG PET and [{sup 18}F]FDG PET/CT to the diagnosis of osteomyelitis and implant-associated infections, enabling timely and appropriate decision-making for further therapy options. [{sup 18}F]FDG PET or PET/CT was performed in 215 patients with suspected osteomyelitis or implant-associated infections between 2000 and 2013. We assessed the diagnostic accuracy of both modalities together and separately with reference to intraoperative microbial findings, with a mean clinical follow-up of 69 ± 49 months. Infections were diagnosed clinically in 101 of the 215 patients. PET and PET/CT scans revealed 87 true-positive, 76 true-negative, 38 false-positive, and 14 false-negative results, indicating a sensitivity of 86 %, a specificity of 67 %, a positive predictive value (PPV) of 70 %, a negative predictive value (NPV) of 84 % and an accuracy of 76 %. The sensitivity of PET/CT was 88 %, but specificity, PPV, NPV and accuracy (76 %, 76 %, 89 % and 82 %, respectively) were higher than those of stand-alone PET. [{sup 18}F]FDG PET is able to identify with high sensitivity the presence of osteomyelitis in orthopaedic surgery patients with nonspecific clinical symptoms of infection. (orig.)

  6. A Multicenter Retrospective Review of Prone Position Ventilation (PPV in Treatment of Severe Human H7N9 Avian Flu.

    Directory of Open Access Journals (Sweden)

    Yuanda Xu

    Full Text Available Patients with H7N9 avian flu concurrent with severe acute respiratory distress syndrome (ARDS usually have a poor clinical outcome. Prone position ventilation (PPV has been shown to improve the prognosis of patients with severe ARDS. This study explored the effects of PPV on the respiratory and circulatory mechanics of H7N9-infected patients with severe ARDS.Individuals admitted to four hospitals designated for H7N9 patients in Guangdong province were treated with PPV, and their clinical data were recorded before and after receiving PPV.Six of 20 critically ill patients in the ICU received PPV. After treatment with 35 PPV sessions, the oxygenation index (OI values of the six patients when measured post-PPV and post-supine position ventilation (SPV were significantly higher than those measured pre-PPV (P < 0.05.The six patients showed no significant differences in their values for respiratory rate (RR, peak inspiratory pressure (PIP, tidal volume (TV or arterial partial pressure of carbon dioxide (PaCO2 when compared pre-PPV, post-PPV, and post-SPV. Additionally, there were no significant differences in the mean values for arterial pressure (MAP, cardiac index (CI, central venous pressure (CVP, heart rate (HR, lactic acid (LAC levels or the doses of norepinephrine (NE administered when compared pre-PPV, post-PPV, and post-SPV.PPV provided improved oxygenation that was sustained after returning to a supine position, and resulted in decreased carbon dioxide retention. PPV can thus serve as an alternative lung protective ventilation strategy for use in patients with H7N9 avian flu concurrent with severe ARDS.

  7. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  8. Prognostic value of brain proton MR spectroscopy and diffusion tensor imaging in newborns with hypoxic-ischemic encephalopathy treated by brain cooling

    International Nuclear Information System (INIS)

    Ancora, G.; Testa, C.; Tonon, C.; Manners, D.N.; Gramegna, L.L.; Lodi, R.; Grandi, S.; Sbravati, F.; Savini, S.; Corvaglia, L.T.; Faldella, G.; Tani, G.; Malucelli, E.

    2013-01-01

    MRI, proton magnetic resonance spectroscopy ( 1 H-MRS), and diffusion tensor imaging (DTI) have been shown to be of great prognostic value in term newborns with moderate-severe hypoxic-ischemic encephalopathy (HIE). Currently, no data are available on 1 H-MRS and DTI performed in the subacute phase after hypothermic treatment. The aim of the present study was to assess their prognostic value in newborns affected by moderate-severe HIE and treated with selective brain cooling (BC). Twenty infants treated with BC underwent conventional MRI and 1 H-MRS at a mean (SD) age of 8.3 (2.8) days; 15 also underwent DTI. Peak area ratios of metabolites and DTI variables, namely mean diffusivity (MD), axial and radial diffusivity, and fractional anisotropy (FA), were calculated. Clinical outcome was monitored until 2 years of age. Adverse outcome was observed in 6/20 newborns. Both 1 H-MRS and DTI variables showed higher prognostic accuracy than conventional MRI. N-acetylaspartate/creatine at a basal ganglia localisation showed 100 % PPV and 93 % NPV for outcome. MD showed significantly decreased values in many regions of white and gray matter, axial diffusivity showed the best predictive value (PPV and NPV) in the genu of corpus callosum (100 and 91 %, respectively), and radial diffusivity was significantly decreased in fronto white matter (FWM) and fronto parietal (FP) WM. The decrement of FA showed the best AUC (0.94) in the FPWM. Selective BC in HIE neonates does not affect the early and accurate prognostic value of 1 H-MRS and DTI, which outperform conventional MRI. (orig.)

  9. CT perfusion during delayed cerebral ischemia after subarachnoid hemorrhage: distinction between reversible ischemia and ischemia progressing to infarction

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, Charlotte H.P. [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, PO Box 85500, Utrecht, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Vos, Pieter C. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Schaaf, Irene C. van der; Velthuis, Birgitta K.; Dankbaar, Jan Willem [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Vergouwen, Mervyn D.I.; Rinkel, Gabriel J.E. [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, PO Box 85500, Utrecht, Utrecht (Netherlands)

    2015-09-15

    Delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (aSAH) can be reversible or progress to cerebral infarction. In patients with a deterioration clinically diagnosed as DCI, we investigated whether CT perfusion (CTP) can distinguish between reversible ischemia and ischemia progressing to cerebral infarction. From a prospectively collected series of aSAH patients, we included those with DCI, CTP on the day of clinical deterioration, and follow-up imaging. In qualitative CTP analyses (visual assessment), we calculated positive and negative predictive value (PPV and NPV) with 95 % confidence intervals (95%CI) of a perfusion deficit for infarction on follow-up imaging. In quantitative analyses, we compared perfusion values of the least perfused brain tissue between patients with and without infarction by using receiver-operator characteristic curves and calculated a threshold value with PPV and NPV for the perfusion parameter with the highest area under the curve. In qualitative analyses of 33 included patients, 15 of 17 patients (88 %) with and 6 of 16 patients (38 %) without infarction on follow-up imaging had a perfusion deficit during clinical deterioration (p = 0.002). Presence of a perfusion deficit had a PPV of 71 % (95%CI: 48-89 %) and NPV of 83 % (95%CI: 52-98 %) for infarction on follow-up. Quantitative analyses showed that an absolute minimal cerebral blood flow (CBF) threshold of 17.7 mL/100 g/min had a PPV of 63 % (95%CI: 41-81 %) and a NPV of 78 % (95%CI: 40-97 %) for infarction. CTP may differ between patients with DCI who develop infarction and those who do not. For this purpose, qualitative evaluation may perform marginally better than quantitative evaluation. (orig.)

  10. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    Science.gov (United States)

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  11. The diagnostic value of 18F-FDG-PET/CT and MRI in suspected vertebral osteomyelitis - a prospective study.

    Science.gov (United States)

    Kouijzer, Ilse J E; Scheper, Henk; de Rooy, Jacky W J; Bloem, Johan L; Janssen, Marcel J R; van den Hoven, Leon; Hosman, Allard J F; Visser, Leo G; Oyen, Wim J G; Bleeker-Rovers, Chantal P; de Geus-Oei, Lioe-Fee

    2018-05-01

    The aim of this study was to determine the diagnostic value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT) and magnetic resonance imaging (MRI) in diagnosing vertebral osteomyelitis. From November 2015 until December 2016, 32 patients with suspected vertebral osteomyelitis were prospectively included. All patients underwent both 18 F-FDG-PET/CT and MRI within 48 h. All images were independently reevaluated by two radiologists and two nuclear medicine physicians who were blinded to each others' image interpretation. 18 F-FDG-PET/CT and MRI were compared to the clinical diagnosis according to international guidelines. For 18 F-FDG-PET/CT, sensitivity, specificity, PPV, and NPV in diagnosing vertebral osteomyelitis were 100%, 83.3%, 90.9%, and 100%, respectively. For MRI, sensitivity, specificity, PPV, and NPV were 100%, 91.7%, 95.2%, and 100%, respectively. MRI detected more epidural/spinal abscesses. An important advantage of 18 F-FDG-PET/CT is the detection of metastatic infection (16 patients, 50.0%). 18 F-FDG-PET/CT and MRI are both necessary techniques in diagnosing vertebral osteomyelitis. An important advantage of 18 F-FDG-PET/CT is the visualization of metastatic infection, especially in patients with bacteremia. MRI is more sensitive in detection of small epidural abscesses.

  12. A study of asymptomatic bacteriuria in Egyptian school-going children.

    African Journals Online (AJOL)

    Background: Urinary tract infections (UTI) are a common and important clinical problem in childhood. Upper urinary ... tive predictive value (PPV) and negative predictive value. (NPV) in ... nificant bacteriuria in asymptomatic school children by.

  13. Comparison between arthroscopy and magnetic resonance studies of rupture of the anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Torregrosa, A.; Higueras, V.; Marti-Bonmati, L.; Casillas, C.; Sanfeliu, M.

    1999-01-01

    To compare the reliability of magnetic resonance (MR) in the diagnosis of rupture of the anterior cruciate ligament (ACL) with that of arthroscopy in a large series of patients. A series of 149 patients underwent arthroscopy and MR study of the knee. The condition of the ACL was classified as normal, partial rupture (increased signal in the ligament with integral hypointense fibers) or complete rupture (complete interruption or failure to visualize the ligament). The agreement (kappa), sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. MR images of ACL were normal in 114 of 116 normal cases; partial rupture was observed in 4 cases (versus 3 in arthroscopy) and complete rupture in 31 (versus 30 in arthroscopy). The agreement was excellent (kappa: 0.93; p < 0.001). For the diagnosis of normal ACL, the sensitivity of MR was 1, the specificity 0.98, the PPV 0.94 and the NPV 1. For the diagnosis of partial rupture, the sensitivity was 0.67, the specificity 0.98, the PPV 0.50 and the NPV 0.99. For complete rupture, the sensitivity was 0.97, the specificity 0.98, the PPV 0.94 and the NPV 0.99. The high sensitivity and specificity of MR observed in the diagnosis of integral ACL is somewhat reduced in cases of complete rupture and even lower in cases of partial rupture. It is important to differentiate the degree of rupture since the therapeutic management of the patient differs. (Author) 18 refs

  14. Prospective Cohort Study Evaluating the Prognostic Value of Simple EEG Parameters in Postanoxic Coma.

    Science.gov (United States)

    Azabou, Eric; Fischer, Catherine; Mauguiere, François; Vaugier, Isabelle; Annane, Djillali; Sharshar, Tarek; Lofaso, Fréderic

    2016-01-01

    We prospectively studied early bedside standard EEG characteristics in 61 acute postanoxic coma patients. Five simple EEG features, namely, isoelectric, discontinuous, nonreactive to intense auditory and nociceptive stimuli, dominant delta frequency, and occurrence of paroxysms were classified yes or no. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic curve (AUC) of each of these variables for predicting an unfavorable outcome, defined as death, persistent vegetative state, minimally conscious state, or severe neurological disability, as assessed 1 year after coma onset were computed as well as Synek's score. The outcome was unfavorable in 56 (91.8%) patients. Sensitivity, specificity, PPV, NPV, and AUC of nonreactive EEG for predicting an unfavorable outcome were 84%, 80%, 98%, 31%, and 0.82, respectively; and were all very close to the ones of Synek score>3, which were 82%, 80%, 98%, 29%, and 0.81, respectively. Specificities for predicting an unfavorable outcome were 100% for isoelectric, discontinuous, or dominant delta activity EEG. These 3 last features were constantly associated to unfavorable outcome. Absent EEG reactivity strongly predicted an unfavorable outcome in postanoxic coma, and performed as accurate as a Synek score>3. Analyzing characteristics of some simple EEG features may easily help nonneurophysiologist physicians to investigate prognostic issue of postanoxic coma patient. In this study (a) discontinuous, isoelectric, or delta-dominant EEG were constantly associated with unfavorable outcome and (b) nonreactive EEG performed prognostic as accurate as a Synek score>3. © EEG and Clinical Neuroscience Society (ECNS) 2015.

  15. Validation and optimisation of an ICD-10-coded case definition for sepsis using administrative health data

    Science.gov (United States)

    Jolley, Rachel J; Jetté, Nathalie; Sawka, Keri Jo; Diep, Lucy; Goliath, Jade; Roberts, Derek J; Yipp, Bryan G; Doig, Christopher J

    2015-01-01

    Objective Administrative health data are important for health services and outcomes research. We optimised and validated in intensive care unit (ICU) patients an International Classification of Disease (ICD)-coded case definition for sepsis, and compared this with an existing definition. We also assessed the definition's performance in non-ICU (ward) patients. Setting and participants All adults (aged ≥18 years) admitted to a multisystem ICU with general medicosurgical ICU care from one of three tertiary care centres in the Calgary region in Alberta, Canada, between 1 January 2009 and 31 December 2012 were included. Research design Patient medical records were randomly selected and linked to the discharge abstract database. In ICU patients, we validated the Canadian Institute for Health Information (CIHI) ICD-10-CA (Canadian Revision)-coded definition for sepsis and severe sepsis against a reference standard medical chart review, and optimised this algorithm through examination of other conditions apparent in sepsis. Measures Sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were calculated. Results Sepsis was present in 604 of 1001 ICU patients (60.4%). The CIHI ICD-10-CA-coded definition for sepsis had Sn (46.4%), Sp (98.7%), PPV (98.2%) and NPV (54.7%); and for severe sepsis had Sn (47.2%), Sp (97.5%), PPV (95.3%) and NPV (63.2%). The optimised ICD-coded algorithm for sepsis increased Sn by 25.5% and NPV by 11.9% with slightly lowered Sp (85.4%) and PPV (88.2%). For severe sepsis both Sn (65.1%) and NPV (70.1%) increased, while Sp (88.2%) and PPV (85.6%) decreased slightly. Conclusions This study demonstrates that sepsis is highly undercoded in administrative data, thus under-ascertaining the true incidence of sepsis. The optimised ICD-coded definition has a higher validity with higher Sn and should be preferentially considered if used for surveillance purposes. PMID:26700284

  16. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  17. Prognostic value of brain proton MR spectroscopy and diffusion tensor imaging in newborns with hypoxic-ischemic encephalopathy treated by brain cooling

    Energy Technology Data Exchange (ETDEWEB)

    Ancora, G. [Neonatal Intensive Care Unit, Department of Mother and Infant Infermi Hospital of Rimini, Rimini (Italy); Testa, C.; Tonon, C.; Manners, D.N.; Gramegna, L.L.; Lodi, R. [Department of Biomedical and Neuromotor Sciences University of Bologna, MR Functional Unit, Bologna (Italy); Grandi, S.; Sbravati, F.; Savini, S.; Corvaglia, L.T.; Faldella, G. [University of Bologna, Neonatology Unit, Department of Woman, Child and Adolescent Health, Bologna (Italy); Tani, G. [University of Bologna, Radiology Unit, Department of Woman, Child and Adolescent Health, Bologna (Italy); Malucelli, E. [University of Bologna, Department of Pharmacy and Biotechnologies, Bologna (Italy)

    2013-08-15

    MRI, proton magnetic resonance spectroscopy ({sup 1}H-MRS), and diffusion tensor imaging (DTI) have been shown to be of great prognostic value in term newborns with moderate-severe hypoxic-ischemic encephalopathy (HIE). Currently, no data are available on {sup 1}H-MRS and DTI performed in the subacute phase after hypothermic treatment. The aim of the present study was to assess their prognostic value in newborns affected by moderate-severe HIE and treated with selective brain cooling (BC). Twenty infants treated with BC underwent conventional MRI and {sup 1}H-MRS at a mean (SD) age of 8.3 (2.8) days; 15 also underwent DTI. Peak area ratios of metabolites and DTI variables, namely mean diffusivity (MD), axial and radial diffusivity, and fractional anisotropy (FA), were calculated. Clinical outcome was monitored until 2 years of age. Adverse outcome was observed in 6/20 newborns. Both {sup 1}H-MRS and DTI variables showed higher prognostic accuracy than conventional MRI. N-acetylaspartate/creatine at a basal ganglia localisation showed 100 % PPV and 93 % NPV for outcome. MD showed significantly decreased values in many regions of white and gray matter, axial diffusivity showed the best predictive value (PPV and NPV) in the genu of corpus callosum (100 and 91 %, respectively), and radial diffusivity was significantly decreased in fronto white matter (FWM) and fronto parietal (FP) WM. The decrement of FA showed the best AUC (0.94) in the FPWM. Selective BC in HIE neonates does not affect the early and accurate prognostic value of {sup 1}H-MRS and DTI, which outperform conventional MRI. (orig.)

  18. Comparison of 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test in assessing pancreatic exocrine sufficiency in children with chronic pancreatitis.

    Science.gov (United States)

    Wejnarska, Karolina; Kołodziejczyk, Elwira; Ryżko, Józef; Oracz, Grzegorz

    Chronic pancreatitis (CP) in children is still a rare, although increasingly recognized entity. Over the duration of the disease several complications can be observed, two of which are major ones: endo- and exocrine insufficiency. In the medical care of children with CP it is crucial to diagnose the decreased endo- and exocrine function of the pancreas, in order to preserve patients from malnutrition and the failure to thrive. The aim of the study was to compare the usefulness of two indirect methods of assessing the pancreas exocrine function in children with CP. Ninety one patients with CP were enrolled in the study (41 boys, 50 girls, aged 2-17.8 years). Only Patients who had had both the 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test (13C -MTBT) performed were selected. We compared the results of both tests for sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) in detecting exocrine pancreatic insufficiency. Out of 91 patients, 12 were diagnosed with exocrine pancreatic insufficiency (EPI). The sensitivity of the fecal fat quantification was 50%, the specificity for the test was 100%. PPV and NPV were 100% and 93%, respectively. 13C-MTBT had the sensitivity of 42% and the specificity of 99%. PPV and NPV for the breath test were of 83% and 92%, respectively. No statistically significant discrepancy between the values obtained was found. Although the 72-hour fecal fat quantification remains the gold standard in detecting EPI, both of the methods that had been investigated were shown to be comparable regarding sensitivity, specificity, PPV and NPV in assessing pancreas exocrine sufficiency in children with CP. Due to the easier execution of the breath test, both for the patient and for medical personnel, its importance may increase.

  19. Comparison of Diagnostic Performance of US Elastography and Conventional B-mode US in Differentiation of Breast Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ji Young; Lee, Jin Hwa; Cho, Jin Han; Ha, Dong Ho; Park, Byeong Ho; Choi, Sun Seob [Dept. of Radiology, Dong-A University College of Medicine, Busan (Korea, Republic of); Kim, Eun Kyung [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Shin, Su Young [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Byeong Ho [Dept. of Preventive Medicine, Dong-A University College of Medicine, Busan (Korea, Republic of)

    2012-08-15

    The purpose of this study was to compare the diagnostic performance of ultrasound (US) elastography and conventional B-mode US for discrimination between benign and malignant breast lesions. During a 13-month period, 277 women with 335 sonographically visible breast lesions who were scheduled to undergo biopsy were examined with US elastography. Elastographic findings were classified as benign or malignant based on the area ratio, with 1.00 as the threshold. Findings on conventional B mode US were classified according to the BI-RADS category, as follows: lesions of BIRADS categories 2 and 3 were considered benign, while those in categories 4 and 5 were considered malignant. Statistical analysis included sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and ROC curve analysis for comparison of the diagnostic performance of US elastography and conventional B-mode US. Of the 335 breast lesions, 85 (25.4%) showed malignancy on pathology. Findings on B-mode US showed malignancy in 264 (78.8%) and elastographic findings showed malignancy in 102 (30.4%). The sensitivity, specificity, PPV, NPV, and accuracy of B-mode US and elastography were 98.8%, 28.0%, 31.8%, 98.6%, and 79.4% and 69.4%, 81.2%, 57.8%, 88.8%, and 79.4%, respectively. Elastography showed significantly higher specificity and PPV and lower sensitivity and NPV, compared with B-mode US (p < 0.001). The area under the ROC curve (AUC value) was 0.761 for elastography, and 0.634 for B-mode US (p < 0.001). US elastography can improve specificity and PPV of B-mode US, but with significant sacrifice of sensitivity and NPV. Therefore, US elastography may complement B-mode US for differentiation of breast masses.

  20. Measurement of kVp, PPV and air kerma values in function of the electric current quantity and the focus-detector distance in one X-ray equipment

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F. de; Potiens, Maria da Penha A.; Vivolo, Vitor

    2009-01-01

    The objective of this work was to study the behavior of the X-ray equipment Pantak/Seifert, model MXR-160/22 of the calibration laboratory of IPEN, LCI, operating in the diagnostic radiology radiation quality RQR 5 (70 kV). For this evaluation it was used a noninvasive meter PTW, Diavolt TM model. The measurements of kVp, PPV and Dose (air kerma), were made varying the electric current and distance between the focal point and the meter. This behavior is described in the literature and was expected in the analysis of the measurements for comparison purposes. For the tests where it was only increased the electric current it was waited a linear increase of the dose (air kerma), but not a variation in the kVp and PPV. The measurements had corresponded to the waited behavior, since the Dose (air kerma) measurements presented a linear increase with the increase of the electric current and the kVp and PPV values showed a variation less than 2%. In the corresponding measurements increasing the distance between focal point and meter, it was waited the exponentially decreasing of the Dose (air kerma) and again a small variation or no variation of the PPV and kVP with the increase of the distance. Over again the measurements corresponded to the expected, where the Dose (air kerma) decreased exponentially and the PPV and the kVp had a variation less than 1.5%. (author)

  1. Serum anti-PLA2R antibody as a diagnostic biomarker of idiopathic membranous nephropathy: The optimal cut-off value for Chinese patients.

    Science.gov (United States)

    Liu, Yipeng; Li, Xuan; Ma, Chaoqun; Wang, Ping; Liu, Ju; Su, Hong; Zhuo, Hao; Kong, Xianglei; Xu, Dayu; Xu, Dongmei

    2018-01-01

    The M-type phospholipase A2 receptor (PLA2R) is a specific target autoantigen identified in idiopathic membranous nephropathy (IMN). The autoantibody against PLA2R (anti-PLA2R) may be used to diagnose IMN. However, the appropriate diagnosis cut-off value for Chinese patients with IMN has not been established. In total, 119 patients who underwent renal biopsy (57 patients with IMN and 62 patients with non-IMN glomerulonephritis) and 22 healthy individuals were recruited for our observation study from Qianfoshan Hospital between September 2011 and March 2016. The serum concentration of anti-PLA2R was measured using a quantitative enzyme-linked immunosorbent assay (ELISA). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and receiver operating characteristic (ROC) curve of anti-PLA2R in diagnosing IMN were analysed based on the ELISA detection. The sensitivity, specificity, PPV, and NPV of anti-PLA2R in the diagnosis of IMN in the Chinese patients were 82.5, 75, 69.1, and 86.3% for the 2RU/ml cut-off value; 78.9, 91.7, 86.5, and 86.5% for the 2.6RU/ml cut-off value; 59.6, 95.2, 89.5, and 77.7% for the 14RU/ml cut-off value; 50.9, 96.4, 90.6, and 74.3% for the 20RU/ml cut-off value; and 47.4, 97.6, 93.1, and 73.2% for the 40RU/ml cut-off value, respectively. The area under the ROC curve was 0.879. The cut-off value of 2.6RU/ml is recommended for the use of anti-PLA2R for the diagnosis of IMN in Chinese patients based on the ELISA. Copyright © 2017. Published by Elsevier B.V.

  2. Staging of cervical endometrial carcinoma using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Vela, A. C.; Oleaga, L.; Cura del, J. L.; Grande, J.; Grande, D.

    1999-01-01

    To demonstrate the benefits of magnetic resonance imaging (MRI) for the staging of endometrial carcinoma and to compare the results of the spin echo (SE) sequence in T2 with the results of the pos gadolinium intravenous study. We have studied 51 women diagnosed with endometrial carcinoma by means of a D and C and confirmed surgically using T1 equipment. All of them have had SE T1 axial sequences, SE in protonic density (PD) and T'' on an axial and sagittal plane carried out on them and 32 cases were studied after the administration of gadolinium intravenously (i. V.). We have valued the depth of the myometrial infiltration and the cervical invasion. The positive predictive value (PPV) and the negative predictive value (VPV) of the MRI to value the deep infiltration of the endometrium were 87.9% and 77.8% respectively. In the 32 cases where we administered gadolinium we obtained a PPV of 90% and a NPV of 83.8%, in both the SE T2 study and the contrast study. In the diagnosis of the cervical invasion we have obtained PPV and NPV values of 75% and 88.1% respectively. In the group of the 32 cases that had the contrast agent administered, we have obtained the same results in both the series: PPV of 80% and NPV of 85.2%. We have found a high correlation index between the staging using MRI and pathological anatomy, especially in stages I and II of the IFGO (International Federation of Gynecology and Obstretics) classification. The use of gadolinium has not varied the results obtained with the SE T2 series. (Author) 18 refs

  3. Seroprevalence of varicella antibodies among pregnant women in Lyon-France

    International Nuclear Information System (INIS)

    Saadatian-Elahi, M.; Mekki, Y.; Signore, C. del; Lina, B.; Derrough, T.; Caulin, E.; Thierry, J.; Vanhems, P.

    2007-01-01

    The purpose of the study was to calculate the seroprevalence of immunity to the varicella-zoster virus (VZV) infection and to evaluate the positive predictive value (PPV) and the negative predictive value (NPV) of the self-reported history of VZV infection in pregnant women. A cross sectional study was conducted in 18 private medical analysis laboratories. Information on socio-demographic characteristics and past history of varicella or zoster were collected using a questionnaire. Blood samples were obtained to determine the serological levels of past exposure to VZV. Overall, 486 pregnant women were recruited. The seroprevalence of VZV antibodies was 98.8%. Six women were seronegative, of whom four were primiparous. The PPV was high (99.5%) while the NPV was only 10.3%. The PPV is a reliable marker of prior VZV infection. In contrast, a negative history does not predict lack of immunity and should be completed by serological analysis which might be introduced to routine antenatal blood tests

  4. Enhancement in fluorescence quantum yield of MEH-PPV:BT blends for polymer light emitting diode applications

    Science.gov (United States)

    Nimith, K. M.; Satyanarayan, M. N.; Umesh, G.

    2018-06-01

    We have investigated the effect of blending electron deficient heterocycle Benzothiadiazole (BT) on the photo-physical properties of conjugated polymer Poly [2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV). Quantum yield (QY) value has been found to increase from 37% for pure MEH-PPV to 45% for an optimum MEH-PPV:BT blend ratio of 1:3. This can be attributed to the efficient energy transfer from the wide bandgap BT (host) to the small bandgap MEH-PPV (guest). The FTIR spectrum of MEH-PPV:BT blended thin film indicates suppression of aromatic C-H out-of-plane and in-plane bending, suggesting planarization of the conjugated polymer chains and, hence, leading to increase in the conjugation length. The increase in conjugation length is also evident from the red-shifted PL spectra of MEH-PPV:BT blended films. Single layer MEH-PPV:BT device shows lower turn-on voltage than single layer MEH-PPV alone device. Further, the effect of electrical conductivity of PEDOT:PSS on the current-voltage characteristics is investigated in the PLED devices with MEH-PPV:BT blend as the active layer. PEDOT:PSS with higher conductivity as HIL reduces the turn on voltage from 4.5 V to 3.9 V and enhances the current density and optical output in the device.

  5. Applicability of McDonald 2010 and Magnetic Resonance Imaging in Multiple Sclerosis (MAGNIMS) 2016 Magnetic Resonance Imaging Criteria for the Diagnosis of Multiple Sclerosis in Sri Lanka.

    Science.gov (United States)

    Gamage, Sujani Madhurika Kodagoda; Wijeweera, Indunil; Wijesinghe, Priyangi; Adikari, Sanjaya Bandara; Fink, Katharina; Sominanda, Herath Mudiyanselage Ajith

    2018-05-31

    The magnetic resonance imaging in multiple sclerosis (MAGNIMS) group recently proposed guidelines to replace the existing dissemination-in-space criteria in McDonald 2010 magnetic resonance imaging (MRI) criteria for diagnosing multiple sclerosis. There has been insufficient research regarding their applicability in Asians. Objective of this study was to determine the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of McDonald 2010 and MAGNIMS 2016 MRI criteria with the aim of verifying their applicability in Sri Lankan patients. Patients with clinically isolated syndrome diagnosed by consultant neurologists were recruited from five major neurology centers. Baseline and follow-up MRI scans were performed within 3 months from the initial presentation and at one year after baseline MRI, respectively. McDonald 2010 and MAGNIMS 2016 MRI criteria were applied to all MRI scans. Patients were followed-up for 2 years to assess the conversion to clinically definite multiple sclerosis (CDMS). The sensitivity, specificity, accuracy, PPV, and NPV for predicting the conversion to CDMS were calculated. Forty-two of 66 patients converted to CDMS. Thirty-seven fulfilled the McDonald 2010 MRI criteria, and 33 converted to CDMS. MAGNIMS 2016 MRI criteria were fulfilled by 29, with 28 converting to CDMS. The sensitivity, specificity, accuracy, PPV, and NPV were 78%, 83%, 64%, 89%, and 69%, respectively, for the McDonald 2010 criteria, and 67%, 96%, 77%, 96%, and 62% for the MAGNIMS 2016 MRI criteria. MAGNIMS 2016 MRI criteria were superior to McDonald 2010 MRI criteria in specificity, accuracy, and PPV, but inferior in sensitivity and NPV. Copyright © 2018 Korean Neurological Association.

  6. Diffusion-Weighted Magnetic Resonance Imaging Early After Chemoradiotherapy to Monitor Treatment Response in Head-and-Neck Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Vandecaveye, Vincent, E-mail: Vincent.Vandecaveye@uzleuven.be [Department of Radiology, University Hospitals Leuven (Belgium); Dirix, Piet [Department of Radiation Oncology, Leuven Cancer Institute, University Hospitals Leuven (Belgium); De Keyzer, Frederik; Op de Beeck, Katya [Department of Radiology, University Hospitals Leuven (Belgium); Vander Poorten, Vincent [Department of Otorhinolaryngology, Head and Neck Surgery, University Hospitals Leuven (Belgium); Hauben, Esther [Department of Pathology, University Hospitals Leuven (Belgium); Lambrecht, Maarten; Nuyts, Sandra [Department of Radiation Oncology, Leuven Cancer Institute, University Hospitals Leuven (Belgium); Hermans, Robert [Department of Radiology, University Hospitals Leuven (Belgium)

    2012-03-01

    Purpose: To evaluate diffusion-weighted imaging (DWI) for assessment of treatment response in head and neck squamous cell carcinoma (HNSCC) three weeks after the end of chemoradiotherapy (CRT). Methods and Materials: Twenty-nine patients with HNSCC underwent magnetic resonance imaging (MRI) prior to and 3 weeks after CRT, including T{sub 2}-weighted and pre- and postcontrast T{sub 1}-weighted sequences and an echo-planar DWI sequence with six b values (0 to 1,000 s/mm{sup 2}), from which the apparent diffusion coefficient (ADC) was calculated. ADC changes 3 weeks posttreatment compared to baseline ( Increment ADC) between responding and nonresponding primary lesions and adenopathies were correlated with 2 years locoregional control and compared with a Mann-Whitney test. In a blinded manner, the Increment ADC was compared to conventional MRI 3 weeks post-CRT and the routinely implemented CT, on average 3 months post-CRT, which used size-related and morphological criteria. Positive and negative predictive values (PPV and NPV, respectively) were compared between the Increment ADC and anatomical imaging. Results: The Increment ADC of lesions with later tumor recurrence was significantly lower than lesions with complete remission for both primary lesions (-2.3% {+-} 0.3% vs. 80% {+-} 41%; p < 0.0001) and adenopathies (19.9% {+-} 32% vs. 63% {+-} 36%; p = 0.003). The Increment ADC showed a PPV of 89% and an NPV of 100% for primary lesions and a PPV of 70% and an NPV of 96% for adenopathies per neck side. DWI improved PPV and NPV compared to anatomical imaging. Conclusion: DWI with the Increment ADC 3 weeks after concluding CRT for HNSCC allows for early assessment of treatment response.

  7. Psychiatric patient disposition agreement between the emergency physician and the psychiatry consultant.

    Science.gov (United States)

    Chakravarthy, Bharath; Menchine, Michael; Thompson, Daniel E; Rajeev, Sindhya; Santos, Barbara-Jean

    2013-01-01

    Mental illness is prevalent, disabling, and costly. Emergency department (ED) visits for mental health-related reasons are on the increase. Determine the level of agreement between emergency physicians and psychiatrists regarding psychiatric patient disposition. We conducted a prospective, observational study at a private university hospital ED from October 2008-April 2009 using a convenience sample of patients of all ages with psychiatric complaints who received formal psychiatric consultation during their ED visit. The emergency physician completed a data sheet prior to psychiatric consultation, assessing the likelihood of admission for psychiatric evaluation. We evaluated the positive predictive value (PPV) and negative predictive value (NPV) of the emergency physician admission decision for all patients before psychiatric consultation, compared with the patients' actual disposition as determined by the consulting psychiatrist. The study captured 230 subjects, 53% of whom were suicidal patients. 74% of patients were eventually admitted. The emergency physician decision to admit for inpatient psychiatric evaluation had a PPV of 87.3% (CI 81.4-91.9%) and an NPV of 66.7% (CI 52.9-78.6%) compared to the psychiatrist decision for the total sample, and a PPV of 90% (CI 82.4-95.1%) and an NPV of 69.6% (CI 47.1-86.8%) for suicidal patients. Additionally, the κ score, a measure of agreement between emergency physician disposition decision and psychiatrist disposition decision, was 0.530 (Cl 0.404-0.656). 95% of patients with an ED assessment of "definitely admit" were eventually admitted by the psychiatrist. Emergency physician disposition has a high PPV (87.3%) and a moderate NPV (66.7%) compared to psychiatrist disposition.

  8. Non-contrast magnetic resonance imaging for bladder cancer: fused high b value diffusion-weighted imaging and T2-weighted imaging helps evaluate depth of invasion

    International Nuclear Information System (INIS)

    Lee, Minsu; Oh, Young Taik; Jung, Dae Chul; Park, Sung Yoon; Shin, Su-Jin; Cho, Nam Hoon; Choi, Young Deuk

    2017-01-01

    To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. (orig.)

  9. Non-contrast magnetic resonance imaging for bladder cancer: fused high b value diffusion-weighted imaging and T2-weighted imaging helps evaluate depth of invasion

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Minsu; Oh, Young Taik; Jung, Dae Chul; Park, Sung Yoon [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Shin, Su-Jin [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Hanyang University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Cho, Nam Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Choi, Young Deuk [Yonsei University College of Medicine, Department of Urology, Seoul (Korea, Republic of)

    2017-09-15

    To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. (orig.)

  10. Comparison of initial and tertiary centre second opinion reads of multiparametric magnetic resonance imaging of the prostate prior to repeat biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Nienke L. [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology, Aachen (Germany); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Koo, Brendan C.; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Warren, Anne Y. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Pathology, Cambridge (United Kingdom); Doble, Andrew; Gnanapragasam, Vincent; Bratt, Ola; Kastner, Christof [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Urology, Cambridge (United Kingdom); Barrett, Tristan [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); University of Cambridge School of Clinical Medicine, Department of Radiology, Box 218, Cambridge (United Kingdom)

    2017-06-15

    To investigate the value of second-opinion evaluation of multiparametric prostate magnetic resonance imaging (MRI) by subspecialised uroradiologists at a tertiary centre for the detection of significant cancer in transperineal fusion prostate biopsy. Evaluation of prospectively acquired initial and second-opinion radiology reports of 158 patients who underwent MRI at regional hospitals prior to transperineal MR/untrasound fusion biopsy at a tertiary referral centre over a 3-year period. Gleason score (GS) 7-10 cancer, positive predictive value (PPV) and negative (NPV) predictive value (±95 % confidence intervals) were calculated and compared by Fisher's exact test. Disagreement between initial and tertiary centre second-opinion reports was observed in 54 % of cases (86/158). MRIs had a higher NPV for GS 7-10 in tertiary centre reads compared to initial reports (0.89 ± 0.08 vs 0.72 ± 0.16; p = 0.04), and a higher PPV in the target area for all cancer (0.61 ± 0.12 vs 0.28 ± 0.10; p = 0.01) and GS 7-10 cancer (0.43 ± 0.12 vs 0.2 3 ± 0.09; p = 0.02). For equivocal suspicion, the PPV for GS 7-10 was 0.12 ± 0.11 for tertiary centre and 0.11 ± 0.09 for initial reads; p = 1.00. Second readings of prostate MRI by subspecialised uroradiologists at a tertiary centre significantly improved both NPV and PPV. Reporter experience may help to reduce overcalling and avoid overtargeting of lesions. (orig.)

  11. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2015-10-01

    To assess the role of STIR, T2-weighted TSE and DWIBS sequences for detecting and characterizing breast lesions and to compare unenhanced (UE)-MRI results with contrast-enhanced (CE)-MRI and histological findings, having the latter as the reference standard. Two hundred eighty consecutive patients (age range, 27-73 years; mean age±standard deviation (SD), 48.8±9.8years) underwent MR examination with a diagnostic protocol including STIR, T2-weighted TSE, THRIVE and DWIBS sequences. Two radiologists blinded to both dynamic sequences and histological findings evaluated in consensus STIR, T2-weighted TSE and DWIBS sequences and after two weeks CE-MRI images searching for breast lesions. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and CE-MRI were calculated. UE-MRI results were also compared with CE- MRI. UE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 94%, 79%, 86%, 79% and 94%, respectively. CE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 98%, 83%, 90%, 84% and 98%, respectively. No statistically significant difference between UE-MRI and CE-MRI was found. Breast UE-MRI could represent an accurate diagnostic tool and a valid alternative to CE-MRI for evaluating breast lesions. STIR and DWIBS sequences allow to detect breast lesions while T2-weighted TSE sequences and ADC values could be useful for lesion characterization. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Comparison of pH and refractometry index with calcium concentrations in preparturient mammary gland secretions of mares.

    Science.gov (United States)

    Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Tsujimura, Koji; Nambo, Yasuo

    2013-01-15

    To test the usefulness of measuring pH and refractometry index, compared with measuring calcium carbonate concentration, of preparturient mammary gland secretions for predicting parturition in mares. Evaluation study. 27 pregnant Thoroughbred mares. Preparturient mammary gland secretion samples were obtained once or twice daily 10 days prior to foaling until parturition. The samples were analyzed for calcium carbonate concentration with a water hardness kit (151 samples), pH with pH test paper (222 samples), and refractometry index with a Brix refractometer (214 samples). The sensitivity, specificity, and positive and negative predictive values for each test were calculated for evaluation of predicting parturition. The PPV within 72 hours and the NPV within 24 hours for calcium carbonate concentration determination (standard value set to 400 μg/g) were 93.8% and 98.3%, respectively. The PPV within 72 hours and the NPV within 24 hours for the pH test (standard value set at 6.4) were 97.9% and 99.4%, respectively. The PPV within 72 hours and the NPV within 24 hours for the Brix test (standard value set to 20%) were 73.2% and 96.5%, respectively. Results suggested that the pH test with the standard value set at a pH of 6.4 would be useful in the management of preparturient mares by predicting when mares are not ready to foal. This was accomplished with equal effectiveness of measuring calcium carbonate concentration with a water hardness kit.

  13. Evaluation of insulin-like growth factor-1 and insulin like growth factor binding protein-3 in diagnosis of growth hormone deficiency in short-stature children

    International Nuclear Information System (INIS)

    Ali, A.; Hashim, R.; Khan, F.A.; Sattar, A.; Ijaz, A.; Manzoor, S.M.; Younas, M.

    2009-01-01

    Growth Hormone Deficiency (GHD) is conventionally diagnosed and confirmed by diminished peak Growth Hormone (GH) levels to provocative testing. Serum Insulin-like growth factor-1 (IGF-1) and insulin-like growth factor binding protein-3 (IGFBP-3) are under the influence of GH and reflect the spontaneous endogenous GH secretion. Owing to the absence of a circadian rhythm, it is possible to take individual measurements of IGF-1 and IGFBP-3 at any time of the day for evaluation of GH status instead of subjecting the individual to cumbersome provocative tests. Objectives of this study were to compare IGF-1 and IGFBP-3 assays with Exercise and L-Dopa stimulation tests in the diagnosis of growth hormone deficiency in short stature children using ITT as gold standard. Methods: This validation study was conducted at Department of Chemical Pathology and Endocrinology, AFIP, Rawalpindi, from November 2005 to October 2006. Fifty-two short stature children were included in the study. Basal samples for GH levels and simultaneous IGF-1 and IGFBP-3 measurements were obtained and afterwards all children were subjected to sequential exercise and LDopa stimulation tests. Insulin Tolerance Test (ITT) was performed one week later with all the necessary precautionary measures. On the basis of ITT results, children were divided into two groups, i.e., 31 growth hormone deficient and 21 Normal Variant Short Stature (NVSS). Results: The diagnostic value of exercise stimulation test remained highest with sensitivity 90.3%, specificity 76.0%, Positive Predictive Value (PPV) 84.84%, Negative Predictive Value (NPV) 84.2% and accuracy 84.6%. The conventional L-Dopa stimulation had sensitivity 96.7%, specificity 38.0%, PPV 69.7%, NPV 88.8 % and accuracy 73.0%. The serum IGF-1 and IGFBP-3 levels were positively correlated with post ITT peak GH levels (r= 0.527, r=0.464 respectively, both p<0.001). The diagnostic value of IGF-1 had sensitivity 83.87%, specificity 76.2%, PPV 83.87%, NPV 76.2% and

  14. Value of Fat-Suppressed Proton-Density-Weighted Turbo Spin-Echo Sequences in Detecting Meniscal Lesions: Comparison with Arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Schaefer, P.J.; Brossmann, J.; Frahm, C.; Hilgert, R.E.; Heller, M.; Jahnke, T.

    2006-01-01

    Purpose: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging (MRI) compared to arthroscopy in the detection of meniscal lesions. Material and Methods: In a prospective study, 31 knee joints were imaged on a 1.5T MR scanner before arthroscopy using the following sequences: (a) coronal and sagittal FS-PDw TSE (TR/TE: 4009/15 ms); (b) coronal T1w SE (TR/TE: 722/20 ms), and sagittal PDw TSE (TR/TE: 3800/15 ms). Other imaging parameters were: slice thickness 3 mm, FOV 160 mm, matrix 256x256. A total of 186 meniscal regions (62 menisci; anterior horn, body, posterior horn) were evaluated. Standard of reference was arthroscopy. Sensitivity, specificity, negative predictive value (npv), positive predictive value (ppv), and accuracy were calculated. Results: Arthroscopically, meniscal lesions were detected in 55/186 segments (35 medial and 20 lateral meniscal lesions). Sensitivity, specificity, npv, ppv, and accuracy for combination of coronal and sagittal FS PDw TSE were 91.4%, 98.3%, 95%, 97%, and 93.5% for the medial meniscus, and 90%, 98.6%, 97.3%, 94.7%, and 96.8% for the lateral. The results were comparable to the combination of coronal T1w SE and sagittal PDw TSE for the medial (88.6%, 98.3%, 93.4%, 96.9%, 91.4%) and the lateral (90%, 95.9%, 97.2%, 85.7%, 92.5%) meniscus. Conclusion: FS PDw TSE-MR sequences are an excellent alternative for the detection of meniscal lesions in comparison with diagnostic arthroscopy

  15. Predicting Outcome in Comatose Patients: The Role of EEG Reactivity to Quantifiable Electrical Stimuli

    Directory of Open Access Journals (Sweden)

    Gang Liu

    2016-01-01

    Full Text Available Objective. To test the value of quantifiable electrical stimuli as a reliable method to assess electroencephalogram reactivity (EEG-R for the early prognostication of outcome in comatose patients. Methods. EEG was recorded in consecutive adults in coma after cardiopulmonary resuscitation (CPR or stroke. EEG-R to standard electrical stimuli was tested. Each patient received a 3-month follow-up by the Glasgow-Pittsburgh cerebral performance categories (CPC or modified Rankin scale (mRS score. Results. Twenty-two patients met the inclusion criteria. In the CPR group, 6 of 7 patients with EEG-R had good outcomes (positive predictive value (PPV, 85.7% and 4 of 5 patients without EEG-R had poor outcomes (negative predictive value (NPV, 80%. The sensitivity and specificity were 85.7% and 80%, respectively. In the stroke group, 6 of 7 patients with EEG-R had good outcomes (PPV, 85.7%; all of the 3 patients without EEG-R had poor outcomes (NPV, 100%. The sensitivity and specificity were 100% and 75%, respectively. Of all patients, the presence of EEG-R showed 92.3% sensitivity, 77.7% specificity, 85.7% PPV, and 87.5% NPV. Conclusion. EEG-R to quantifiable electrical stimuli might be a good positive predictive factor for the prognosis of outcome in comatose patients after CPR or stroke.

  16. HPV-testing versus HPV-cytology co-testing to predict the outcome after conization.

    Science.gov (United States)

    Bruhn, Laerke Valsøe; Andersen, Sisse Josephine; Hariri, Jalil

    2018-06-01

    The purpose of this study was to determine the feasibility of human Papillomavirus (HPV) testing alone as a prognostic tool to predict recurrent disease within a three-year follow-up period after treatment for cervical intraepithelial neoplasia (CIN)2 + . Retrospectively, 128 women with histologically verified CIN2 + who had a conization performed at Southern Jutland Hospital in Denmark between 1 January 2013 and 31 December 2013 were included. Histology, cytology and HPV test results were obtained for a three-year follow-up period. 4.7% (6/128) of the cases developed recurrent disease during follow-up. Of the cases without free margins, recurrent dysplasia was detected normal in 10.4% (5/48), whereas in the group with free margins it was 1.3% (1/80). The post-conization HPV test was negative in 67.2% (86/128) and Pap smear normal in 93.7% (120/128). Combining resection margins, cytology and HPV had sensitivity for prediction of recurrent dysplasia of 100%. Specificity was 45.8%, positive predictive value (PPV) 8.5% and negative predictive value (NPV) 100%. Using HPV test alone as a predictor of recurrent dysplasia gave a sensitivity of 83.3%, specificity 69.7%, PPV 11.9% and NPV 98.8%. Combining resection margin and HPV test had a sensitivity of 100%, specificity 45.9%, PPV 8.3% and NPV 100%. HPV test at six months control post-conization gave an NPV of 98.8% and can be used as a solitary test to identify women at risk for recurrent disease three years after treatment for precursor lesions. Using both resection margin and HPV test had a sensitivity of 100% and NPV 100%. Adding cytology did not increase the predictive value. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  17. Application of Mycobacterium Leprae-specific cellular and serological tests for the differential diagnosis of leprosy from confounding dermatoses.

    Science.gov (United States)

    Freitas, Aline Araújo; Hungria, Emerith Mayra; Costa, Maurício Barcelos; Sousa, Ana Lúcia Osório Maroccolo; Castilho, Mirian Lane Oliveira; Gonçalves, Heitor Sá; Pontes, Maria Araci Andrade; Duthie, Malcolm S; Stefani, Mariane Martins Araújo

    2016-10-01

    Mycobacterium leprae-specific serological and cell-mediated-immunity/CMI test were evaluated for the differential diagnosis of multibacillary/MB, and paucibacillary/PB leprosy from other dermatoses. Whole-blood assay/WBA/IFNγ stimulated with LID-1 antigen and ELISA tests for IgG to LID-1 and IgM to PGL-I were performed. WBA/LID-1/IFNγ production was observed in 72% PB, 11% MB leprosy, 38% dermatoses, 40% healthy endemic controls/EC. The receiver operating curve/ROC for WBA/LID-1 in PB versus other dermatoses showed 72.5% sensitivity, 61.5% specificity and an area-under-the-curve/AUC=0.75; 74% positive predictive value/PPV, 59% negative predictive value/NPV. Anti PGL-I serology was positive in 67% MB, 8% PB leprosy, 6% of other dermatoses; its sensitivity for MB=66%, specificity=93%, AUC=0.89; PPV=91%, NPV=72%. Anti-LID-1 serology was positive in 87% MB, 7% PB leprosy, all other participants were seronegative; 87.5% sensitivity for MB, 100% specificity, AUC=0.97; PPV=100%, NPV=88%. In highly endemic areas anti-LID-1/PGL-I serology and WBA/LID-1-represent useful tools for the differential diagnosis of leprosy from other confounding dermatoses. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Enhancing Breast Cancer Recurrence Algorithms Through Selective Use of Medical Record Data.

    Science.gov (United States)

    Kroenke, Candyce H; Chubak, Jessica; Johnson, Lisa; Castillo, Adrienne; Weltzien, Erin; Caan, Bette J

    2016-03-01

    The utility of data-based algorithms in research has been questioned because of errors in identification of cancer recurrences. We adapted previously published breast cancer recurrence algorithms, selectively using medical record (MR) data to improve classification. We evaluated second breast cancer event (SBCE) and recurrence-specific algorithms previously published by Chubak and colleagues in 1535 women from the Life After Cancer Epidemiology (LACE) and 225 women from the Women's Health Initiative cohorts and compared classification statistics to published values. We also sought to improve classification with minimal MR examination. We selected pairs of algorithms-one with high sensitivity/high positive predictive value (PPV) and another with high specificity/high PPV-using MR information to resolve discrepancies between algorithms, properly classifying events based on review; we called this "triangulation." Finally, in LACE, we compared associations between breast cancer survival risk factors and recurrence using MR data, single Chubak algorithms, and triangulation. The SBCE algorithms performed well in identifying SBCE and recurrences. Recurrence-specific algorithms performed more poorly than published except for the high-specificity/high-PPV algorithm, which performed well. The triangulation method (sensitivity = 81.3%, specificity = 99.7%, PPV = 98.1%, NPV = 96.5%) improved recurrence classification over two single algorithms (sensitivity = 57.1%, specificity = 95.5%, PPV = 71.3%, NPV = 91.9%; and sensitivity = 74.6%, specificity = 97.3%, PPV = 84.7%, NPV = 95.1%), with 10.6% MR review. Triangulation performed well in survival risk factor analyses vs analyses using MR-identified recurrences. Use of multiple recurrence algorithms in administrative data, in combination with selective examination of MR data, may improve recurrence data quality and reduce research costs. © The Author 2015. Published by Oxford University Press. All rights reserved. For

  19. [Total serum calcium and corrected calcium as severity predictors in acute pancreatitis].

    Science.gov (United States)

    Gutiérrez-Jiménez, A A; Castro-Jiménez, E; Lagunes-Córdoba, R

    2014-01-01

    To evaluate total serum calcium (TC) and albumin-corrected calcium (ACC) as prognostic severity factors in acute pancreatitis (AP). Ninety-six patients were included in the study. They were diagnosed with AP and admitted to the Hospital Regional de Veracruz within the time frame of January 2010 to December 2012. AP severity was determined through the updated Atlanta Classification (2013). TC and ACC values were measured in the first 24hours of admittance and the percentages of sensitivity (S), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR-) were calculated through ROC curves and contingency tables. In accordance with the updated Atlanta Classification, 70 patients presented with mild AP, 17 with moderately severe AP, and 9 with severe AP. Of the patient total, 61.5% were women, and 69.8% presented with biliary etiology. The maximum TC cut-off point was 7.5mg/dL, with values of S, 67%; Sp, 82%; PPV, 27%, and NPV, 96%. The maximum ACC cut-off point was 7.5mg/dL, with values of S, 67%; Sp, 90%; PPV, 40%; NPV, 96%. Both had values similar to those of the Ranson and APACHE II prognostic scales. TC and ACC, measured within the first 24hours, are useful severity predictors in acute pancreatitis, with sensitivity and predictive values comparable or superior to those of the conventional prognostic scales. Copyright © 2013 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  20. Solar Cell Polymer Based Active Ingredients PPV and PCBM

    Science.gov (United States)

    Hardeli, H.; Sanjaya, H.; Resikarnila, R.; Nitami H, R.

    2018-04-01

    A polymer solar cell is a solar cell based on a polymer bulk heterojunction structure using the method of thin film, which can convert solar energy into electrical energy. Absorption of light is carried by active material layer PPV: PCBM. This study aims to make solar cells tandem and know the value of converting solar energy into electrical energy and increase the value of efficiency generated through morphological control, ie annealing temperature and the ratio of active layer mixture. The active layer is positioned above the PEDOT:PSS layer on ITO glass substrate. The characterization results show the surface morphology of the PPV:PCBM active layer is quite evenly at annealing temperature of 165 ° C. The result of conversion of electrical energy with a UV light source in annealing samples with temperature 165 ° C is 0.03 mA and voltage of 4.085 V with an efficiency of 2.61% and mixed ratio variation was obtained in comparison of P3HT: PCBM is 1: 3

  1. COMPARISON OF CR MAMMOGRAPHY, SONOMAMMOGRAPHY AND REAL-TIME ELASTOGRAPHY IN EVALUATING BREAST LESIONS

    Directory of Open Access Journals (Sweden)

    Onteddu Joji Reddy

    2016-11-01

    Full Text Available BACKGROUND Breast cancer is the most common cause of cancer deaths in women worldwide. As early detection can decrease the deaths due to breast cancer, high sensitive and specific tests are necessary to evaluate breast lesions. MATERIALS AND METHODS 80 patients with complaint of pain or lump in the breast or nipple discharge were evaluated by mammography, sonomammography and real-time elastography. Imaging studies were compared with the FNAC/biopsy of lesions. RESULTS Mammography has sensitivity, specificity, PPV, NPV as 80%, 95.5%, 93.3%, 86%, respectively. Sonomammography has sensitivity, specificity, PPV, NPV as 74.2%, 91%, 86%, 82%, respectively. Real-time elastography has sensitivity, specificity, PPV, NPV as 91.4%, 94.4%, 94.1%, 91.8%, respectively. Combined mammography and sonomammography has sensitivity, specificity, PPV, NPV as 82.8%, 93.3%, 90.6%, 87.5%, respectively. Combined sonomammography and elastography has sensitivity, specificity, PPV, NPV as 91.4%, 97.2%, 96.96%, 92.1%, respectively. CONCLUSIONS Combination of CR mammography, sonomammography and real-time elastography has high diagnostic sensitivity and specificity in the diagnosis of benign and malignant breast masses obviating the use of higher modalities like MRI, CAD and digital tomosynthesis, which is very useful in resource poor countries like India.

  2. Value of digital radiography in expiration in detection of pneumothorax; Wertigkeit der digitalen Roentgenaufnahme in Exspiration zum Nachweis eines Pneumothorax

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, L.; Natho, O.; Feigen, U.; Kivelitz, D. [Asklepios Klinik St. Georg, Hamburg (Germany). Dept. of Radiology; Schulz, U. [medistat GmbH, Kiel (Germany). Medical Statistics

    2014-03-15

    Purpose: The purpose of this study was to find out whether pneumothorax detection and exclusion is superior in expiratory digital chest radiography. Materials and Methods: 131 patients with pneumothorax with paired inspiratory and expiratory chest radiographs were analyzed regarding localization and size of pneumothorax. Sensitivity, specificity, negative (npv) and positive predictive value (ppv) as well as the positive (LR+) and negative likelihood ratio (LR-) were determined in a blinded randomized interobserver study with 116 patients. The evaluation was performed by three board-certified radiologists. Results: In 131 patients, there were 139 pneumothoraces, 135 (97.1 %) were located apical, 88 (63.3 %) lateral and 33 (23.7 %) basal. Sensitivity was 99 % for inspiratory and 97 % for expiratory radiographs. The interobserver study yielded a mean sensitivity of 86.1 %/86.1 %, specificity of 97.3 %/93.4 %, npv of 88.7 %/88.5 % and ppv of 96.7 %/92.1 % for inspiration/expiration. For inspiratory radiographs the LR+/LR- were 40.2/0.14 and for expiration 13.9 and 0.15. McNemar-Test showed no significant difference for the detection of pneumothoraces in in-/exspiration. Conclusion: Inspiratory and expiratory digital radiographs are equally suitable for pneumothorax detection. Inspiratory radiographs are recommended as the initial examination of choice for pneumothorax detection, an additional expiratory radiograph is only recommended in doubtful cases. (orig.)

  3. The iliac wing sign: An indicator of the presence of bone and/or soft-tissue injury of the pelvis and hips

    Energy Technology Data Exchange (ETDEWEB)

    Kakigi, Takahide, E-mail: t.a.kakigi@dance.ocn.ne.jp [Department of Radiology, Saiseikai Ibaraki Hospital, 2-1-45 Mitsukeyama, Ibaraki, Osaka 567-0035 (Japan); Hosono, Makoto, E-mail: hosono@med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, 377-2 Ohno-higashi, Osakasayama, Osaka 589-8511 (Japan); Shimono, Taro [Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585 (Japan); Hiraoka, Taizo; Nishimura, Kazumasa [Department of Radiology, Saiseikai Ibaraki Hospital, 2-1-45 Mitsukeyama, Ibaraki, Osaka 567-0035 (Japan)

    2012-09-15

    Purpose: To prospectively evaluate the feasibility of using the “iliac wing sign (IWS)” as an indicator of bone and/or soft-tissue injury of the pelvis and hips on magnetic resonance (MR) imaging. IWS means edema of the iliacus muscle attachment entering the iliac wing that is visualized as a linear high signal intensity on fat-suppressed T2-weighted MR images. Methods: Consecutive 106 patients who complained of hip pain were enrolled in this study. We evaluated the correlation between IWS and bone and/or soft-tissue injury of the pelvis and hips using Fisher's exact test. Further, performance parameters of sensitivity, specificity, accuracy, the positive predictive value (PPV), and negative predictive value (NPV) of IWS were calculated. Results: Thirty-eight of the 106 (36%) patients had bone and/or soft-tissue injury. Twenty-seven of these 38 (71%) patients with injury showed a positive IWS, while only 11 of 68 (16%) patients without injury showed a positive IWS (p < .0001). IWS, thus, yielded a sensitivity of 71%, specificity of 84%, accuracy of 79%, positive predictive value (PPV) of 71%, and negative predictive value (NPV) of 84%. Conclusion: In cases with a positive IWS, the careful interpretation of MR images is needed because injury presence is highly likely, as suggested by the relatively high sensitivity and PPV. IWS absence may mean a low probability of injury because of the high specificity and NPV.

  4. Evaluation of an automated spike-and-wave complex detection algorithm in the EEG from a rat model of absence epilepsy.

    Science.gov (United States)

    Bauquier, Sebastien H; Lai, Alan; Jiang, Jonathan L; Sui, Yi; Cook, Mark J

    2015-10-01

    The aim of this prospective blinded study was to evaluate an automated algorithm for spike-and-wave discharge (SWD) detection applied to EEGs from genetic absence epilepsy rats from Strasbourg (GAERS). Five GAERS underwent four sessions of 20-min EEG recording. Each EEG was manually analyzed for SWDs longer than one second by two investigators and automatically using an algorithm developed in MATLAB®. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the manual (reference) versus the automatic (test) methods. The results showed that the algorithm had specificity, sensitivity, PPV and NPV >94%, comparable to published methods that are based on analyzing EEG changes in the frequency domain. This provides a good alternative as a method designed to mimic human manual marking in the time domain.

  5. A Multicenter Retrospective Review of Prone Position Ventilation (PPV) in Treatment of Severe Human H7N9 Avian Flu.

    Science.gov (United States)

    Xu, Yuanda; Deng, Xilong; Han, Yun; Zhou, Lixin; He, Weiqun; Chen, Sibei; Nong, Lingbo; Huang, Huang; Zhang, Yan; Yu, Tieou; Li, Yimin; Liu, Xiaoqing

    2015-01-01

    Patients with H7N9 avian flu concurrent with severe acute respiratory distress syndrome (ARDS) usually have a poor clinical outcome. Prone position ventilation (PPV) has been shown to improve the prognosis of patients with severe ARDS. This study explored the effects of PPV on the respiratory and circulatory mechanics of H7N9-infected patients with severe ARDS. Individuals admitted to four hospitals designated for H7N9 patients in Guangdong province were treated with PPV, and their clinical data were recorded before and after receiving PPV. Six of 20 critically ill patients in the ICU received PPV. After treatment with 35 PPV sessions, the oxygenation index (OI) values of the six patients when measured post-PPV and post-supine position ventilation (SPV) were significantly higher than those measured pre-PPV (P protective ventilation strategy for use in patients with H7N9 avian flu concurrent with severe ARDS.

  6. 82Rb Cardiac PET in patients with known ischemic heart disease – a direct comparison with 15O-water Cardiac PET

    DEFF Research Database (Denmark)

    Hoff, Camilla Molich; Tolbod, Lars Poulsen; Harms, Hans

    2017-01-01

    for both tracers and the extraction correction by Lortie et al for 82Rb. Comparisons included 1) correlation of absolute MBF for 82Rb versus 15O-water, 2) standard clinical practice for 82Rb using assessment of static, gated and dynamic scans by 2 experienced physicians (consensus), 3) in-house established...... was false positive in seven and false negative in zero, yielding a sensitivity of 100%, specificity 64%, PPV 68 % and NPV 100%. Comparing stress MBF, 82Rb on the patient-level was false positive in one and false negative in five, yielding a sensitivity of 71%, specificity 95%, PPV 92% and NPV 81......%. On the vessel-level there were six false positive and 24 false negative, yielding a sensitivity of 51%, specificity 91%, PPV 81% and NPV 72%. Global CFR (patient-level) identified five false positive and 10 false negative with a sensitivity of 41%, specificity 77%, PPV 58% and NPV 63%. Conclusion Standard...

  7. New intrarenal echo-Doppler velocimetric indices for the diagnosis of renal artery stenosis.

    Science.gov (United States)

    Bardelli, M; Veglio, F; Arosio, E; Cataliotti, A; Valvo, E; Morganti, A

    2006-02-01

    We aimed at comparing the positive and negative predictive values (PPV, NPV) of several intrarenal velocimetric indices for revealing the presence of renal artery stenosis (RAS) among hypertensive patients who underwent a renal angiography for the clinical suspicion of renovascular hypertension. In 106 patients (200 kidneys), the pulsatility index (PI) and resistive index (RI), the acceleration time (AT), and the mean systolic acceleration (ACC(sys)) were evaluated. In addition, the maximal systolic acceleration (ACC(max)), that is, the maximal slope of the acceleration phase, and the maximal acceleration index (AI(max)), that is, the ratio between ACC(max) and the relative peak systolic velocity, were calculated. On angiography, we found that 56 (28%) of the 200 arteries had a greater than 60% RAS. PI and RI had an NPV below 75%, whereas AT, ACC(sys), ACC(max), and AI(max) had an NPV always above 95%. However, ACC(max), and AI(max), at their best cutoff limits, had higher PPV than ACC(sys) and AT (60 and 70% vs 45 and 51%, respectively). Thus, in a cohort of patients with a high prevalence of RAS, PI and RI failed to reach an NPV adequate for a screening test. In contrast, all the acceleration indices we tested had a sufficiently high NPV but AI(max) appears superior to the others because of higher PPV. We propose the evaluation of AI(max) as an additional screening test in patients with hypertension and the clinical suspicion of RAS.

  8. Accuracy of contrast-enhanced dual-energy MDCT for the assessment of iodine uptake in renal lesions.

    Science.gov (United States)

    Mileto, Achille; Marin, Daniele; Ramirez-Giraldo, Juan Carlos; Scribano, Emanuele; Krauss, Bernhard; Mazziotti, Silvio; Ascenti, Giorgio

    2014-05-01

    The objective of our study was to assess the accuracy of iodine-related attenuation and iodine quantification as imaging biomarkers of iodine uptake in renal lesions on a single-phase nephrographic image with dual-energy MDCT. Fifty-nine patients (41 men, 18 women; age range, 28-84 years) with 80 renal lesions underwent contrast-enhanced dual-energy CT during the nephrographic phase of enhancement. Renal lesions were characterized as enhancing or nonenhancing on color-coded iodine overlay maps using iodine-related attenuation (in Hounsfield units) and iodine quantification (in milligrams per milliliter). For iodine-related attenuation the iodine uptake thresholds of 15 and 20 HU were tested; a threshold of 0.5 mg/mL was used for iodine quantification. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of iodine-related attenuation and iodine quantification were calculated from chi-square tests of contingency with histopathology or imaging follow-up as the reference standard. The 95% CIs were calculated from binomial expression. Differences in sensitivity and specificity were assessed by means of McNemar analysis. A significant difference in sensitivity and specificity was found between iodine-related attenuation with the thresholds of 15 HU (sensitivity, 91.4%; specificity, 93.3%; PPV, 91.4%; NPV, 93.3%) and 20 HU (sensitivity, 77.1%; specificity, 100%; PPV, 100%; NPV, 84.9%) (p = 0.008) and between iodine quantification (sensitivity, 100%; specificity, 97.7%; PPV, 97.2%; NPV, 100%) and iodine-related attenuation with a threshold of 20 HU (p = 0.004). No significant difference in sensitivity and specificity was found between iodine quantification and iodine-related attenuation with a threshold of 15 HU. Contrast-enhanced dual-energy MDCT with iodine-related attenuation and iodine quantification allows accurate evaluation of iodine uptake in renal lesions on a single-phase nephrographic image.

  9. Both semiquantitative degree of rest Tl-201 uptake and reversibility at 24 hour-delay were needed to predict wall motion improvement after bypass surgery

    International Nuclear Information System (INIS)

    Lee, D. S.; Yoon, S. N.; Kim, K. B.; Jeong, Z. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Controversy still exists about how to use the uptake at rest and 24 hour delay in rest redistribution Tl-201 SPECT to predict improvement of wall motion abnormality after bypass surgery. To find the best way to combine diagnostic efficacy of Tl-201 SPECT to predict myocardial viability, we studied the predictive values (positive: PPV, negative: NPV) of rest and 24 hour-delay Tl-201 SPECT in 21 patients. Wall motion was assessed comparing preoperative post-stress gated Tc-99m-MIBI SPECT with that of 3 months after surgery. Four point scoring system was used for 17 myocardial segments to asses uptakes ( 0 to 3 for normal to defect) at rest and 24 hour-delay and wall motion ( 0 to 3 for normal to dyskinesia). Ejection fraction improved after surgery (5011% vs 4313%). Intra-observer and inter-observer reproducibility of EF was 7 and 9% respectively when we used 3D Perfusion-Motion Map. Sixty seven segments showed wall motion abnormality before surgery. Predictive values of rest Tl-201 uptake decrease were as follows: 0: 15/15(100%), 1: 30/34(88%), 2: 6/11 (55%), 3: 3/7(43%). So PPV of mild decrease was 88%, and NPV of severe decrease was 50%. Delayed reversibility was evaluated in 37 segments (15 patients). Twenty seven segment had persistence or aggravation, but the other 10 segments improved at 24 hour delay. PPV of reversible 10 segments was 80%, and NPV of reversibility was only 46%. PPV of combination of rest Tl-201 uptake of mild degree and 24 hour reversibility was 86% (38/44) and NPV of neither one was 88%. We concluded that both semi-quantitative degree of Tl-201 uptake at rest and reversibility at 24 hour delay was the best to warrant or abandon postoperative improvement of abnormal wall motion found at preoperative post-stress gated myocardial SPECT

  10. Screening for Underage Drinking and Diagnostic and Statistical Manual of Mental Disorders, 5th Edition Alcohol Use Disorder in Rural Primary Care Practice.

    Science.gov (United States)

    Clark, Duncan B; Martin, Christopher S; Chung, Tammy; Gordon, Adam J; Fiorentino, Lisa; Tootell, Mason; Rubio, Doris M

    2016-06-01

    To examine the National Institute on Alcohol Abuse and Alcoholism Youth Guide alcohol frequency screening thresholds when applied to Diagnostic and Statistical Manual of Mental Disorders, 5th Edition (DSM-5) diagnostic criteria, and to describe alcohol use patterns and alcohol use disorder (AUD) characteristics in rural youth from primary care settings. Adolescents (n = 1193; ages 12 through 20 years) visiting their primary care practitioner for outpatient visits in six rural primary care clinics were assessed prior to their practitioner visit. A tablet computer collected youth self-report of past-year frequency and quantity of alcohol use and DSM-5 AUD symptoms. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined. For early adolescents (ages 12 through 14 years), 1.9% met DSM-5 criteria for past-year AUD and ≥3 days with alcohol use in the past year yielded a screen for DSM-5 with optimal psychometric properties (sensitivity: 89%; specificity: 95%; PPV: 37%; NPV: 100%). For middle adolescents (ages 15 through 17 years), 9.5% met DSM-5 AUD criteria, and ≥3 past year drinking days showed optimal screening results (sensitivity: 91%; specificity: 89%; PPV: 50%; NPV: 99%). For late adolescents (ages 18 through 20 years), 10.0% met DSM-5 AUD criteria, and ≥12 past year drinking days showed optimal screening results (sensitivity: 92%; specificity: 75%; PPV: 31%; NPV: 99%). The age stratified National Institute on Alcohol Abuse and Alcoholism frequency thresholds also produced effective results. In rural primary care clinics, 10% of youth over age 14 years had a past-year DSM-5 AUD. These at-risk adolescents can be identified with a single question on alcohol use frequency. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. The Value of a Checklist for Child Abuse in Out-of-Hours Primary Care: To Screen or Not to Screen.

    Directory of Open Access Journals (Sweden)

    Maartje Cm Schouten

    Full Text Available To assess the diagnostic value of the screening instrument SPUTOVAMO-R2 (checklist, 5 questions for child abuse at Out-of-hours Primary Care locations (OPC, by comparing the test outcome with information from Child Protection Services (CPS. Secondary, to determine whether reducing the length of the checklist compromises diagnostic value.All children (<18 years attending one of the participating OPCs in the region of Utrecht, the Netherlands, in a year time, were included. The checklist is an obligatory field in the electronic patient file. CPS provided data on all checklist positives and a sample of 5500 checklist negatives (dataset. The checklist outcome was compared with a report to CPS in 10 months follow up after the OPC visit.The checklist was filled in for 50671 children; 108 (0.2% checklists were positive. Within the dataset, 61 children were reported to CPS, with emotional neglect as the most frequent type of abuse (32.8%. The positive predictive value (PPV of the checklist for child abuse was 8.3 (95% CI 3.9-15.2. The negative predictive value (NPV was 99.1 (98.8-99.3, with 52 false negatives. When the length of the checklist was reduced to two questions closely related to the medical process (SPUTOVAMO-R3, the PPV was 9.1 (3.7-17.8 and the NPV 99.1 (98.7-99.3. These two questions are on the injury in relation to the history, and the interaction between child and parents.The checklist SPUTOVAMO-R2 has a low detection rate of child abuse within the OPC setting, and a high false positive rate. Therefore, we recommend to use the shortened checklist only as a tool to increase the awareness of child abuse and not as a diagnostic instrument.

  12. Value of magnetic resonance imaging in prenatal diagnosis of placental accretism; Valor da ressonancia magnetica no diagnostico antenatal do acretismo placentario

    Energy Technology Data Exchange (ETDEWEB)

    Francisco, Viviane Vieira; Goldman, Suzan Menasce; Faria, Juliano; Szejnfeld, Jacob [Universidade Federal de Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: vieira_francisco@uol.com.br

    2006-12-15

    Purpose: to establish the main signs of placental accretism in magnetic resonance imaging (MRI) in patients with clinical suspicion and to estimate the benefit of this method. Methods: prospective transversal study with 15 patients suspected of placental accretism, referred between March 2003 and February 2006. Gestational age varied from 20 to 31 weeks. All patients underwent MRI to study the placenta and had previously done an ultrasonography. Material was sent to histological study. MRI was done on Magnetom Impact and Sonata Maestro Class Siemens{sup R}, with acquired sequences HASTE, TURBO SPIN in axial, sagittal, coronal planes and echo gradient (GE{sup R}), pre- and post-dynamic contrast in the best plan for acquisition. Images were analyzed by a team of two radiologists. Results: mean gestational age was 24.3 weeks. We studied seven placenta previa (47%), six anterior placentas (40%) and two posterior placentas (13%). Ultrasonography was positive in 80% of the placentas and MRI in 53%. However, echography had a low concordance with anatomic pathological studies by Kappa test (11%), revealing 75% of sensitivity, 14% of specificity, 50% as positive predictive value (PPV) and 33% as negative predictive value (NPV). MRI had an excellent concordance with anatomic pathological studies (0.86), showing 100% of sensitivity, 86% of specificity, 89% as PPV and 100% as NPV. Conclusions: MRI is useful for placental accretism diagnosis. The principal findings are transmural hyper-signal, the loss of continuity in myometrial wall in fast sequences and the identification of vessels invading myometrial layer in dynamic sequences. (author)

  13. Danske PPV-stammer har ændret sig genetisk

    DEFF Research Database (Denmark)

    Hjulsager, Charlotte Kristiane; Krog, Jesper Schak; Larsen, Lars Erik

    2015-01-01

    I 2015 er der set en markant stigning i antallet af positive fund af porcin parvovirus (PPV) i indsendelser til undersogelse af svineaborter (Tabel 1). PPV forekommer udbredt i svinebesætninger og kan forårsage reproduktionsproblemer. Disse kan imidlertid kontrolleres med vacciner, der dog ikke...... forhindrer infektion og virusudskillelse fra soerne, men beskytter mod reproduktionsproblemerne. PPV-viruspartiklerne er meget modstandsdygtige overfor nedbrydelse i omgivelserne, så da virus formodentlig findes i de fleste besatninger, er det vigtigt med effektiv vaccination af alle avlsdyr for at beskytte...

  14. Renal scintigraphy with DMSA 99 mTc and the direct radionuclide cystogram in children with recurrent urinary tract infections

    International Nuclear Information System (INIS)

    Donoso R, Gilda; Lobo S, Gabriel; Arteaga V, Maria de la Paz; Arnello V, Francisca; Jimenez, Cesar; Perez, Andres

    2003-01-01

    The aim of this study was to correlate the results of Renal Scintigraphy (RS) and the Direct Radionuclide Cystogram (DRC) in children with recurrent urinary tract infections. Method: we analyse 92 children, 82 % females , with ages ranging from 1 month- 12 years old (mean:4,3 years old). Both techniques were performed conventionally with a gammacamera/ computer system. We determined the concordance or discordance between them, and the positive and negative predictive value (PPV, NPV ) of one method with respect the other. For statistical analysis we use Chi square and MacNemar test. Results: 45 % of the RS were abnormal, and the 27 % of DRC was positive. We found a concordance of the results in both techniques in 70 % (p< 0.001) .For the RS vs DRC the PPV was 46% and the NPV was 88%. For the DRC vs RS the PPV was the 76 % and the NPV was 67%. Conclusions. 1.- : 1.- the normality of RS is a better predictor of normality than DRC. 2.-The abnormality of DRC predicts better the abnormality of RS than the inverse. 3.- The results of both techniques show a significant concordance (author)

  15. Endometrial carcinoma: merit of magnetic resonance in pre-surgical staging; Carcinoma de endometrio: valor de la estadificacion prequirurgica por resonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, E.; Barrera, M. C.; Gervas, C.; Salvador, E.; Rivero, B. [Hospital Donostia. San sebastian (Spain); Sentis, M. [Corporacio Sanitaria Pare Tauli. Sabadell (Spain)

    2003-07-01

    To evaluate MR capacity in assessing deep myometrial and cervical infiltrations in cases of endometrial carcinoma. A series of 30 consecutively diagnosed endometrial cancer patients was pre-surgically evaluated by means of magnetic resonance (MR). TSE-T2 sequences with fat saturation and dynamic FFe sequence were used after gadolinium administration. A correlation with post-surgical histological stating was made. There were then determined sensitivity (S), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) for the deep myometrial infiltration and cervical invasion. Cases of overestimation and underestimation were analyzed. Values obtained for myometrium and cervix were, respectively, S of 67% and 63%, SP of 89% and 91%, PPV of 80% and 71% and NPV of 80% and 87%. Two cases each were over valued for myometrial infiltration and cervix: four cases and 3 cases, respectively, were undervalues. MR stating in cases of endometrial carcinoma is a highly reliable diagnostic technique, but it does present certain limitations. (Author) 19 refs.

  16. Endometrial carcinoma: merit of magnetic resonance in pre-surgical staging

    International Nuclear Information System (INIS)

    Fernandez, E.; Barrera, M. C.; Gervas, C.; Salvador, E.; Rivero, B.; Sentis, M.

    2003-01-01

    To evaluate MR capacity in assessing deep myometrial and cervical infiltrations in cases of endometrial carcinoma. A series of 30 consecutively diagnosed endometrial cancer patients was pre-surgically evaluated by means of magnetic resonance (MR). TSE-T2 sequences with fat saturation and dynamic FFe sequence were used after gadolinium administration. A correlation with post-surgical histological stating was made. There were then determined sensitivity (S), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) for the deep myometrial infiltration and cervical invasion. Cases of overestimation and underestimation were analyzed. Values obtained for myometrium and cervix were, respectively, S of 67% and 63%, SP of 89% and 91%, PPV of 80% and 71% and NPV of 80% and 87%. Two cases each were over valued for myometrial infiltration and cervix: four cases and 3 cases, respectively, were undervalues. MR stating in cases of endometrial carcinoma is a highly reliable diagnostic technique, but it does present certain limitations. (Author) 19 refs

  17. The Role of Positron Emission Tomography/Computed Tomography Imaging in Head and Neck Cancer after Radical Chemoradiotherapy: a Single Institution Experience.

    Science.gov (United States)

    Nelissen, C; Sherriff, J; Jones, T; Guest, P; Colley, S; Sanghera, P; Hartley, A

    2017-11-01

    Positron emission tomography/computed tomography (PET/CT) is used to restage head and neck cancer 3 months after chemoradiotherapy. The purpose of this study was to determine the negative predictive value (NPV) of a scan reported as having no abnormal uptake and the positive predictive values (PPV) for different maximum standardised uptake value (SUVmax) thresholds. Patients with squamous cell carcinoma of the oro-/hypopharynx/larynx (n = 206) were included. SUVmax and subsequent locoregional recurrence were documented. The median SUVmax was 11.2 (range 4-33)/4.6 (range 2-30), respectively, in patients with/without definite primary site recurrence (P = 0.004). The median SUVmax was 4.4 (range 2.6-15.6)/3.1 (range 2.1-4.6), respectively, in patients with/without definite nodal recurrence (P = 0.003). The NPV for a scan reported as having no abnormal uptake was 92%. The PPV for the SUVmax thresholds 4, 6 and 8, respectively, were 53, 65 and 92% (primary site) and 93, 100 and 100% (nodes). The NPV of PET/CT after chemoradiation is consistent with the literature and underlines the importance of PET/CT in restaging the primary site if salvage neck dissection is considered. The overall PPV of PET/CT remains low but is high for nodal SUVmax > 4. These data could be used to design risk-stratified follow-up schedules. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. [Evaluation of a rapid diagnostic test in the diagnosis of toxoplasmosis in pregnant women in Cotonou (Bénin)].

    Science.gov (United States)

    Ogouyèmi-Hounto, A; Agbayahoun-Chokki, F; Sissinto Savi de Tove, Y; Biokou Bankole, B; Adinsi de Souza, V; Assogba, M; Kinde-Gazard, D; Massougbodji, A

    2014-05-01

    The aim of the study was to evaluate the performance of the ImmunoComb® Toxo IgG and ImmunoComb® Toxo IgMassays (rapid diagnostic test) in the laboratory diagnosis of toxoplasmosis in pregnant women in Cotonou. We interviewed 266 pregnant women, who first answered an epidemiological questionnaire, and collected blood samples for measurement of IgG and IgM anti T. gondii antibodies with the ImmunoComb toxo assays and with the ARCHITECT CIMA method. The sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) were calculated to determine the performance of the rapid test. The seroprevalences of IgG against T. gondii by CIMA technique and rapid test were respectively 48.9% and 48.5%. The prevalence increased with age. Performances for IgG were: sensitivity 97%, specificity 100%, PPV 100%, NPV = 97.10%. For IgM, Sensitivity: 33.3% Specificity: 100%, PPV 100%, NPV = 99.2%. Seroprevalence obtained shows that about half of the study population is not immune against T. gondii and requires regular serological monitoring until delivery. According to these results, and given the needs of toxoplasmosis diagnosis on the field characterized by an important decrease of immunized women, this test may be recommended in the laboratory diagnosis of toxoplasmosis in peripheral levels of the health pyramid.

  19. Diagnostic accuracy of CT in assessing extra-regional lymphadenopathy in pancreatic and peri-ampullary cancer: a systematic review and meta-analysis.

    Science.gov (United States)

    Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus

    2014-12-01

    Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Performance of Rapid Diagnostic Tests for Imported Malaria in Clinical Practice: Results of a National Multicenter Study

    Science.gov (United States)

    Houzé, Sandrine; Boutron, Isabelle; Marmorat, Anne; Dalichampt, Marie; Choquet, Christophe; Poilane, Isabelle; Godineau, Nadine; Le Guern, Anne-Sophie; Thellier, Marc; Broutier, Hélène; Fenneteau, Odile; Millet, Pascal; Dulucq, Stéphanie; Hubert, Véronique; Houzé, Pascal; Tubach, Florence; Le Bras, Jacques; Matheron, Sophie

    2013-01-01

    We compared the performance of four rapid diagnostic tests (RDTs) for imported malaria, and particularly Plasmodium falciparum infection, using thick and thin blood smears as the gold standard. All the tests are designed to detect at least one protein specific to P. falciparum ( Plasmodium histidine-rich protein 2 (PfHRP2) or Plasmodium LDH (PfLDH)) and one pan-Plasmodium protein (aldolase or Plasmodium LDH (pLDH)). 1,311 consecutive patients presenting to 9 French hospitals with suspected malaria were included in this prospective study between April 2006 and September 2008. Blood smears revealed malaria parasites in 374 cases (29%). For the diagnosis of P. falciparum infection, the three tests detecting PfHRP2 showed high and similar sensitivity (96%), positive predictive value (PPV) (90%) and negative predictive value (NPV) (98%). The PfLDH test showed lower sensitivity (83%) and NPV (80%), despite good PPV (98%). For the diagnosis of non-falciparum species, the PPV and NPV of tests targeting pLDH or aldolase were 94–99% and 52–64%, respectively. PfHRP2-based RDTs are thus an acceptable alternative to routine microscopy for diagnosing P. falciparum malaria. However, as malaria may be misdiagnosed with RDTs, all negative results must be confirmed by the reference diagnostic method when clinical, biological or other factors are highly suggestive of malaria. PMID:24098699

  1. Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies

    Directory of Open Access Journals (Sweden)

    Malahiyo Rajabu

    2010-06-01

    Full Text Available Abstract Background The diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi. However, a more rapid, simpler, and cheaper diagnostic method would be very useful especially in developing countries. The Widal test is widely used in Africa but little information exists about its reliability. Methods We assessed the performance of the Widal tube agglutination test among febrile hospitalized Tanzanian children. We calculated the sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV of various anti-TH and -TO titers using culture-confirmed typhoid fever cases as the "true positives" and all other febrile children with blood culture negative for S. typhi as the "true negatives." Results We found that 16 (1% of 1,680 children had culture-proven typhoid fever. A single anti-TH titer of 1:80 and higher was the optimal indicator of typhoid fever. This had a sensitivity of 75%, specificity of 98%, NPV of 100%, but PPV was only 26%. We compared our main findings with those from previous studies. Conclusion Among febrile hospitalized Tanzanian children with a low prevalence of typhoid fever, a Widal titer of ≥ 1:80 performed well in terms of sensitivity, specificity, and NPV. However a test with improved PPV that is similarly easy to apply and cost-efficient is desirable.

  2. Influence of clinical information on the diagnostic validity of MRI in the detection of abacterial sacroiliitis; Einfluss klinischer Informationen auf die diagnostische Wertigkeit der MRT bei der Frage nach einer abakteriellen Sakroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Remplik, P.; Schukai, O.; Roemer, F.W.; Fischer, W.; Buecklein, W.; Mott, K.; Bohndorf, K. [Klinik fuer Diagnostische Radiologie und Neuroradiologie, Klinikum Augsburg (Germany); Schalm, J. [3. Medizinische Klinik, Funktionsbereich Rheumatologie, Klinikum Augsburg (Germany)

    2005-06-01

    Purpose: to evaluate the influence of clinical information on the diagnostic validity of MRI in the detection of abacterial sacroiliitis. Evaluation of sensitivities, specificities, negative (NPV) and positive predictive values (PPV) for MRI with and without clinical information in comparison to a prior defined standard. Materials and methods: the results of routine MRI reports of 65 patients with the clinical suspicion of abacterial sacroiliitis referred by rheumatologists for MR assessment of the sacroiliac joints were retrospectively reviewed. These results were compared to the results of a blinded reading of the same examinations performed without any clinical information. The MRI protocol included T1-SE, STIR and T1-SE contrast-enhanced sequences with fat saturation. All patients were followed for at least four years. The standard of reference was defined by an experienced rheumatologist and included baseline and follow-up data (clinical, laboratory and imaging). Abacterial sacroiliitis was diagnosed in 19 patients. Results: under routine clinical conditions, MRI revealed a sensitivity of 94.7% and specificity of 97.8%. A PPV of 94.7% and a NPV of 97.8% were achieved. Without clinical information, MRI revealed a sensitivity and specificity of 64 and 80%, and a PPV of 49% and a NPV of 86%, respectively. Conclusion: the additional knowledge of clinical information for the MR diagnosis of abacterial sacroiliitis increases its diagnostic value for the assessment of abacterial sacroiliitis. (orig.)

  3. The Usefulness of Clinical-Practice-Based Laboratory Data in Facilitating the Diagnosis of Dengue Illness

    Directory of Open Access Journals (Sweden)

    Jien-Wei Liu

    2013-01-01

    Full Text Available Alertness to dengue and making a timely diagnosis is extremely important in the treatment of dengue and containment of dengue epidemics. We evaluated the complementary role of clinical-practice-based laboratory data in facilitating suspicion/diagnosis of dengue. One hundred overall dengue (57 dengue fever [DF] and 43 dengue hemorrhagic fever [DHF] cases and another 100 nondengue cases (78 viral infections other than dengue, 6 bacterial sepsis, and 16 miscellaneous diseases were analyzed. We separately compared individual laboratory variables (platelet count [PC] , prothrombin time [PT], activated partial thromboplastin time [APTT], alanine aminotransferase [ALT], and aspartate aminotransferase [AST] and varied combined variables of DF and/or DHF cases with the corresponding ones of nondengue cases. The sensitivity, specificity, accuracy, positive predictive value (PPV, and negative predictive value (NPV in the diagnosis of DF and/or DHF were measured based on these laboratory variables. While trade-off between sensitivity and specificity, and/or suboptimal PPV/NPV was found at measurements using these variables, prolonged APTT + normal PT + PC < 100 × 109 cells/L had a favorable sensitivity, specificity, PPV, and NPV in diagnosis of DF and/or DHF. In conclusion, these data suggested that prolonged APTT + normal PT + PC < 100 × 109 cells/L is useful in evaluating the likelihood of DF and/or DHF.

  4. Evaluation of dried blood spot samples for screening of hepatitis C and human immunodeficiency virus in a real-world setting.

    Science.gov (United States)

    Vázquez-Morón, Sonia; Ryan, Pablo; Ardizone-Jiménez, Beatriz; Martín, Dolores; Troya, Jesus; Cuevas, Guillermo; Valencia, Jorge; Jimenez-Sousa, María A; Avellón, Ana; Resino, Salvador

    2018-01-30

    Both hepatitis C virus (HCV) infection and human immunodeficiency virus (HIV) infection are underdiagnosed, particularly in low-income countries and in difficult-to-access populations. Our aim was to develop and evaluate a methodology for the detection of HCV and HIV infection based on capillary dry blood spot (DBS) samples taken under real-world conditions. We carried out a cross-sectional study of 139 individuals (31 healthy controls, 68 HCV-monoinfected patients, and 40 HCV/HIV-coinfected patients). ELISA was used for anti-HCV and anti-HIV antibody detection; and SYBR Green RT-PCR was used for HCV-RNA detection. The HIV serological analysis revealed 100% sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The HCV serological analysis revealed a sensitivity of 92.6%, specificity of 100%, PPV of 100%, and NPV of 79.5%. Finally, the HCV-RNA detection test revealed a detection limit of 5 copies/µl with an efficiency of 100% and sensitivity of 99.1%, specificity of 100%, PPV of 100%, and NPV of 96.9%. In conclusion, our methodology was able to detect both HCV infection and HIV infection from the same DBS sample with good diagnostic performance. Screening for HCV and HIV using DBS might be a key strategy in the implementation of national programs for the control of both infections.

  5. Effect of Pedot-Pss on Electrical and Photovoltaic Properties of ITO/MEH-PPV:PCBM/Al Organic Diodes

    International Nuclear Information System (INIS)

    Gunduz, B.

    2008-01-01

    The photovoltaic and electrical properties of ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al organic diodes have been investigated. The ideality factor, series resistance and shunt resistance values of ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al diodes were found to be 4.6, 6.84x10 6 Ω, 2.2x10 8 Ω and 4.02, 5.8x10 5 Ω, 2x10 7 Ω respectively. The electronic parameters of the ITO/MEH-PPV:PCBM/Al diode were improved using PEDOT-PSS conducting polymer. ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al organic diodes indicate a photovoltaic behaviour with a maximum open circuit voltage V o c and short-circuit current I s c. The photoconductivity sensitivity and responsivity properties of the organic diodes have been characterized by transient-current measurements. The obtained electrical and photovoltaic results indicate that ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al structures are the organic photodiodes with calculated electronic parameters and the electrical properties of the ITO/MEH-PPV:PCBM/Al diode have been improved with PEDOT-PSS conducting polymer

  6. Effect of solution concentration on MEH-PPV thin films

    Science.gov (United States)

    Affendi, I. H. H.; Sarah, M. S. P.; Alrokayan, Salman A. H.; Khan, Haseeb A.; Rusop, M.

    2018-05-01

    MEH-PPV thin films were prepared with a mixture of THF (tetrahydrofuran) solution deposited by spin coating method. The surface topology of MEH-PPV thin film were characterize by atomic force microscopy (AFM) and optical properties of absorption spectra were characterized by using Ultraviolet-visible-near-infrared (UV-Vis-NIR). The MEH-PPV concentration variation affects the surface and optical properties of the thin film where 0.5 mg/ml MEH-PPV concentration have a good surface topology provided the same film also gives the highest absorption coefficient were then deposited to a TiO2 thin film forming composite layer. The composite layer then shows low current flow of short circuit current of Isc = -5.313E-7 A.

  7. Optically active vibrational modes of PPV derivatives on textile substrate

    International Nuclear Information System (INIS)

    Silva, M.A.T. da; Dias, I.F.L.; Santos, E.P. dos; Martins, A.A.; Duarte, J.L.; Laureto, E.; Reis, G.A. dos; Guimarães, P.S.S.; Cury, L.A.

    2013-01-01

    In this work, MEH-PPV and BDMO-PPV films were deposited by spin-coating on “dirty” textile substrates of canvas, nylon, canvas with resin, jeans and on glass and the temperature dependence of the optical properties of them was studied by photoluminescence and Raman (300 K) techniques. The temperature dependence of the energy, of the half line width at half height of the purely electronic peak, of the integrated PL intensity and of the Huang-Rhys factor, S=I (01) /I (00) , were obtained directly from the PL spectrum. For an analysis of the vibrational modes involved, Raman measurements were performed on substrates with and without polymers deposited and the results compared with those found in the literature. The films of MEH-PPV and BDMO-PPV showed optical properties similar to those films deposited on other substrates such as glass, metals, etc. It was observed an inversion of the first vibrational band in relation to the purely electronic peak with increasing temperature in the films deposited on nylon and canvas. The vibrational modes obtained by Raman were used to compose the simulation of the PL line shape of BDMO-PPV films on canvas and nylon, using a model proposed by Lin [29]. - Highlights: ► MEH-PPV and BDMO-PPV films were deposited by spin-coating on dirty textile. ► Their properties were studied by photoluminescence and Raman techniques. ► We observed inversion of first vibrational band in relation to purely electronic peak. ► Optically active vibrational modes of PPV derivatives were studied.

  8. Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-non invasive multicenter Italian study for coronary artery disease)

    International Nuclear Information System (INIS)

    Marano, Riccardo; Cobelli, Francesco de; Maschio, Alessandro del; Becker, Christoph; Herzog, Christopher; Centonze, Maurizio; Morana, Giovanni; Gualdi, Gian Franco; Ligabue, Guido; Pontone, Gianluca; Catalano, Carlo; Chiappino, Dante; Midiri, Massimo; Simonetti, Giovanni; Marchisio, Filippo; Olivetti, Lucio; Fattori, Rossella; Bonomo, Lorenzo

    2009-01-01

    This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (≥16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines. (orig.)

  9. Strain ratio ultrasound elastography increases the accuracy of colour-Doppler ultrasound in the evaluation of Thy-3 nodules. A bi-centre university experience.

    Science.gov (United States)

    Cantisani, Vito; Maceroni, Piero; D'Andrea, Vito; Patrizi, Gregorio; Di Segni, Mattia; De Vito, Corrado; Grazhdani, Hektor; Isidori, Andrea M; Giannetta, Elisa; Redler, Adriano; Frattaroli, Fabrizio; Giacomelli, Laura; Di Rocco, Giorgio; Catalano, Carlo; D'Ambrosio, Ferdinando

    2016-05-01

    To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.

  10. Accuracy of preoperative CT T staging of renal cell carcinoma: which features predict advanced stage?

    International Nuclear Information System (INIS)

    Bradley, A.J.; MacDonald, L.; Whiteside, S.; Johnson, R.J.; Ramani, V.A.C.

    2015-01-01

    Aims: To characterise CT findings in renal cell carcinoma (RCC), and establish which features are associated with higher clinical T stage disease, and to evaluate patterns of discrepancy between radiological and pathological staging of RCC. Materials and methods: Preoperative CT studies of 92 patients with 94 pathologically proven RCCs were retrospectively reviewed. CT stage was compared with pathological stage using the American Joint Committee on Cancer (AJCC), 7 th edition (2010). The presence or absence of tumour necrosis, perinephric fat standing, thickening of Gerota's fascia, collateral vessels were noted, and correlated with pT stage. The sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) for predicting pT stage ≥pT3a were derived separately for different predictors using cross-tabulations. Results: Twenty-four lesions were pathological stage T1a, 21 were T1b, seven were T2a, 25 were T3a, 11 were T3b, four were T3c, and two were T4. There were no stage T2b. Sixty-three (67%) patients had necrosis, 27 (29%) thickening of Gerota's fascia (1 T1a), 25 had collateral vessels (0 T1a), 28 (30%) had fat stranding of <2 mm, 20 (21%) of 2–5mm and one (1%) of >5 mm. For pT stage ≥pT3a, the presence of perinephric fat stranding had a sensitivity, specificity, PPV and NPV of 74%, 65%, 63%, and 76%, respectively. Presence of tumour necrosis had a sensitivity, specificity, PPV, and NPV of 81%, 44%, 54%, and 72%, respectively. Thickening of Gerota's fascia had a sensitivity, specificity, PPV, and NPV of 52%, 90%, 81% and 70%, respectively; and enlarged collateral vessels had a sensitivity, specificity, PPV, and NPV value of 52%, 94%, 88%, and 71% respectively. Conclusion: The presence of perinephric stranding and tumour necrosis were not reliable signs for pT stage >T3a. Thickening of Gerota's fascia and the presence of collateral vessels in the peri- or paranephric fat had 90% and 94% specificity, with 82% and 88

  11. Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions-Comparison to arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, Fritz K.W.; Schaefer, Philipp J.; Brossmann, Joachim; Frahm, Christian; Muhle, Claus; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas

    2006-01-01

    Objective: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging for the detection of anterior and posterior cruciate ligament lesions in comparison to arthroscopy. Materials and methods: In a prospective study 31 knee joints were imaged on a 1.5 T MR scanner (Vision[reg], Siemens, Erlangen) prior to arthroscopy using following sequences: (a) sagittal FS-PDw/T2w TSE (TR/TE: 4009/15/105 ms); (b) sagittal PDw/T2w TSE (TR/TE:3800/15/105 ms). Further imaging parameters: slice thickness 3 mm, FOV 160 mm, matrix 256 x 256. A total of 62 anterior and posterior cruciate ligaments (ACL/PCL) were evaluated, standard of reference was arthroscopy. Sensitivity, specificity, positive (ppv) and negative predictive value (npv) and accuracy were calculated. Results: Twenty-one cruciate ligament ruptures were detected in arthroscopy, 19 ACL- and 2 PCL-ruptures (on MRI 34/124, 25/62 ACL, 9/62 PCL lesions). For all four sequences in the 31 patients with arthroscopic correlation sensitivity, specificity, ppv, npv and accuracy were 86%, 98%, 95%, 93% and 94% for detection of tears, and 84%, 100%, 100%, 80% and 90% for ACL-ruptures respectively. The two PCL-ruptures were true positive in all sequences, one intact PCL was diagnosed as torn (false positive). Conclusions: Fat-suppressed PDw/T2w TSE-MR sequences are comparable to PDw TSE sequences for the detection of ACL/PCL-lesions

  12. [Prognostic value of lacrimal duct diagnostics after tube removal : Retrospective analysis of risk of relapse during the first postoperative year after transcanalicular lacrimal duct surgery with silicone tubing].

    Science.gov (United States)

    Böhm, M; Heichel, J; Bredehorn-Mayr, T; Lautenschläger, C; Struck, H-G

    2017-05-01

    Transcanalicular lacrimal duct surgery has become more important over the past two decades. The aim of the study was to prove the prognostic value of postoperative lacrimal syringing and the testing of spontaneous drainage of lacrimal fluid immediately after tube removal. A total of 110 cases with postoperative lacrimal syringing and 183 cases with verification of the postoperative lacrimal fluid drainage performed between January 2001 and August 2008 were retrospectively evaluated. The indication for postoperative diagnostics was set by the investigator. The prognostic value of these two procedures was determined by using prognostic parameters (positive predictive value, PPV; negative predictive value, NPV) and analyzing recurrence nonexistence via Cox regression and Kaplan-Meier estimator. The observation period was limited to 12 months. Predominantly, recurrence was defined on the patient's satisfaction and absence of symptoms, which was determined with the help of a questionnaire. Postoperative verification of the lacrimal syringing is a suitable instrument to estimate surgical success within the first year after lacrimal surgery with a PPV of 92.31%. Testing of the spontaneous drainage of lacrimal fluid after tube removal reached a PPV of 63.33%. The proven prognostic value shows that syringing of the lacrimal duct and verification of spontaneous drainage should be integrated into postoperative care in a standardized manner. Hereby, early information for the patient about the expected result of the surgical procedure is enabled.

  13. Studentized Continuous Wavelet Transform (t-CWT in the Analysis of Individual ERPs: Real and Simulated EEG Data

    Directory of Open Access Journals (Sweden)

    Ruben Gustav Leonhardt Real

    2014-09-01

    Full Text Available This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT as a method for the extraction and assessment of event-related brain potentials (ERP in data from a single subject. Sensitivity, specificity, positive (PPV and negative predictive values (NPV of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings.

  14. Value of oral effervescent powder administration for multidetector CT evaluation of esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ringe, Kristina I., E-mail: ringe.kristina@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Meyer, Simone, E-mail: Meyer.simone.rad@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Ringe, Bastian P., E-mail: Ringe.bastian@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Winkler, Michael, E-mail: Winkler.michael@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Wacker, Frank, E-mail: Wacker.frank@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Raatschen, Hans-Juergen, E-mail: Raatschen.hans-juergen@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany)

    2015-02-15

    Highlights: • Oral effervescent powder improves esophageal distension and wall assessment at CT. • This technique improves detection and T staging of esophageal cancer at CT. • It can be easily adopted in clinical routine in patients with esophageal pathology. - Abstract: Purpose: To assess the value of oral effervescent powder (EP) for evaluation of esophageal distension, and for detection and staging of esophageal cancer with contrast-enhanced CT. Materials and methods: 84 patients without esophageal pathology and 52 patients with histological confirmed diagnosis of esophageal cancer were included in this prospective IRB-approved study. Half of the patients in both groups received EP prior to CT. Esophageal distension was assessed by planimetry of the inner (IA) and outer area (OA). Two blinded readers evaluated the datasets separately with regard to diagnosis of esophageal cancer (yes/no) and staging (T0-T4), if applicable. Distension results were compared (t-Test). In patients with cancer sensitivity, specificity, NPV and PPV were calculated. CT staging results were compared to histopathology (Cohen-k). Results: IA and IA/OA were significantly larger after EP as compared to the group without EP (p < 0.05). Sensitivity, specificity, NPV and PPV for cancer detection cancer were as follows: 78%/78%, 98%/98%, 95%/95%, 87%/87% with EP; 60%/68%, 98%/98%, 94%/94%, 80%/83% without EP. Staging with EP was good (k = 0.84/0.67) and moderate without EP (k = 0.58/0.59). Conclusions: Administration of EP prior to CT results in good distension of the esophagus, and improves detection and staging of esophageal cancer, as compared to control studies without EP.

  15. The Operophtera brumata nucleopolyhedrovirus (OpbuNPV) represents an early, divergent lineage within genus Alphabaculovirus

    Science.gov (United States)

    Operophtera brumata nucleopolyhedrovirus (OpbuNPV) infects larvae of the winter moth, Operophtera brumata. As part of an effort to explore the pesticidal potential of OpbuNPV, an isolate of this virus from Massachusetts (USA), OpbuNPV-MA, was characterized by electron microscopy of OpbuNPV occlusio...

  16. Measurements of diagnostic examination performance using quantitative apparent diffusion coefficient and proton MR spectroscopic imaging in the preoperative evaluation of tumor grade in cerebral gliomas

    International Nuclear Information System (INIS)

    Server, Andres; Kulle, Bettina; Gadmar, Oystein B.; Josefsen, Roger; Kumar, Theresa; Nakstad, Per H.

    2011-01-01

    Purpose: Tumor grading is very important both in treatment decision and evaluation of prognosis. While tissue samples are obtained as part of most therapeutic approaches, factors that may result in inaccurate grading due to sampling error (namely, heterogeneity in tissue sampling, as well as tumor-grade heterogeneity within the same tumor specimen), have led to a desire to use imaging better to ascertain tumor grade. The purpose in our study was to evaluate the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the curve (AUC), and accuracy of diffusion-weighted MR imaging (DWI), proton MR spectroscopic imaging (MRSI) or both in grading primary cerebral gliomas. Materials and methods: We performed conventional MR imaging (MR), DWI, and MRSI in 74 patients with newly diagnosed brain gliomas: 59 patients had histologically verified high-grade gliomas: 37 glioblastomas multiform (GBM) and 22 anaplastic astrocytomas (AA), and 15 patients had low-grade gliomas. Apparent diffusion coefficient (ADC) values of tumor and peritumoral edema, and ADC ratios (ADC in tumor or peritumoral edema to ADC of contralateral white matter, as well as ADC in tumor to ADC in peritumoral edema) were determined from three regions of interest. The average of the mean, maximum, and minimum for ADC variables was calculated for each patient. The metabolite ratios of Cho/Cr and Cho/NAA at intermediate TE were assessed from spectral maps in the solid portion of tumor, peritumoral edema and contralateral normal-appearing white matter. Tumor grade determined with the two methods was then compared with that from histopathologic grading. Logistic regression and receiver operating characteristic (ROC) curve analysis were performed to determine optimum thresholds for tumor grading. Measures of diagnostic examination performance, such as sensitivity, specificity, PPV, NPV, AUC, and accuracy for identifying high-grade gliomas were also calculated

  17. The Effectiveness of a Collector Bag for Measurement of Post ...

    African Journals Online (AJOL)

    The aim of the study was to assess sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of collector bag and its correlation with hemoglobin (Hb) and hematocrit (Ht) variations. This study, carried on 100 women referred for admission to labor ward of Shohada hospital in Orumeyeh City, Iran, ...

  18. Plum pox virus (PPV) genome expression in genetically engineered RNAi plants

    Science.gov (United States)

    An important approach to controlling sharka disease caused by Plum pox virus (PPV) is the development of PPV resistant plants using small interfering RNAs (siRNA) technology. In order to evaluate siRNA induced gene silencing, we studied, based on knowledge of the PPV genome sequence, virus genome t...

  19. Is MRI helpful in assessing the distance of the tumour from the internal os in patients with cervical cancer below FIGO Stage IB2?

    International Nuclear Information System (INIS)

    Bhosale, P.R.; Iyer, R.B.; Ramalingam, P.; Schmeler, K.M.; Wei, W.; Bassett, R.L.; Ramirez, P.T.; Frumovitz, M.

    2016-01-01

    Aim: To determine the ability of magnetic resonance imaging (MRI) in detecting tumour-free margins from the internal os (IO). Materials and methods: A database search yielded 79 women with early-stage cervical cancer who underwent radical hysterectomy and preoperative MRI. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of MRI in assessment of ≤5 and >5 mm IO involvement were calculated with histopathological surgical specimen findings considered to be the reference standard. A main and subset analysis was performed. The subset analysis included only those patients who would have been considered for radical trachelectomy. Results: For predicting a distance between the tumour and the IO of ≤5 mm, MRI had a sensitivity of 73%, a specificity of 98.3%, a PPV of 95%, a NPV of 88.1%, and an accuracy of 89.8% for the main analysis, and sensitivity of 81.8%, a specificity of 93.2% a PPV of 69.2% a NPV of 96.5% and an accuracy of 91.4% for the subset analysis. Conclusion: MRI has high specificity, NPV, and accuracy in detecting tumour from the IO, making MRI suitable for treatment planning in patients desiring trachelectomy to preserve fertility. - Highlights: • Cervical cancer patients who underwent hysterectomy were analyzed on MRI and pathology for involvement of the internal os. • Distance of the tumor from the internal-os was measured on MRI and Pathology and findings were tabulated as > and ≤ 5 mm from the internal os. • MRI has the ability to identify tumor involvement of the internal os. • MRI can help select patients who can undergo trachelectomy safely.

  20. Acute pulmonary embolism: prediction of cor pulmonale and short-term patient survival from assessment of cardiac dimensions in routine multidetector-row CT

    International Nuclear Information System (INIS)

    Engeike, C.; Rummeny, E.; Marten, K.

    2006-01-01

    Purpose: evaluation of the prognostic value of morphological cardiac parameters in patients with suspected and incidental acute pulmonary embolism (PE) using multidetector-row chest CT (MSCT). Materials and methods: 2335 consecutive MSCT scans were evaluated for the presence of PE. The arterial enhancement and analysability of pulmonary arteries and the heart were assessed as parameters of the scan quality. The diastolic right and left ventricular short axes (RV D , LV D ) and the interventricular septal deviation (ISD) were measured in all PE-positive patients and the echocardiography reports were reviewed. The clinical data assessment included cardio-respiratory and other co-morbidities, systemic anticoagulant therapy (ACT), and the 30-day outcome. Predictors of acute cor pulmonale and the short-term outcome were calculated by univariate and multivariate logistic regressions including odds ratios (OR) and ROC analyses using positive (PPV) and negative predictive values (NPV). Results: 90 patients with acute PE were included (36 with clinically suspected PE, 54 with incidental PE). 26 patients had cardio-respiratory co-morbidities. Four patients underwent systemic thrombolysis, 43 underwent anticoagulation in therapeutic doses, 19 underwent anticoagulation in prophylactic doses, and 24 patients did not undergo ACT. 15 of 41 patients had echocardiographic evidence of acute cor pulmonale. 8 patients died within 30 days. The RV D was the best independent predictor of acute cor pulmonale (p = 0,002, OR = 9.16, PPV = 0.68, NPV=1 at 4.49 cm cut off) and short-term outcome (p= 0,0005, OR = 2.82, PPV = 0.23, NPV = 0.98 at 4.75 cm cut off). The RV D /LV D ratio had a PPV of 0.85 for cor pulmonale. (orig.)

  1. The Functional Movement Screen and Injury Risk: Association and Predictive Value in Active Men.

    Science.gov (United States)

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle; Anderson, Morgan K; North, William J; Jones, Bruce H

    2016-02-01

    The Functional Movement Screen (FMS) is a series of 7 tests used to assess the injury risk in active populations. To determine the association of the FMS with the injury risk, assess predictive values, and identify optimal cut points using 3 injury types. Cohort study; Level of evidence, 2. Physically active male soldiers aged 18 to 57 years (N = 2476) completed the FMS. Demographic and fitness data were collected by survey. Medical record data for overuse injuries, traumatic injuries, and any injury 6 months after the FMS assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated along with the receiver operating characteristic (ROC) to determine the area under the curve (AUC) and identify optimal cut points for the risk assessment. Risks, risk ratios (RRs), odds ratios (ORs), and 95% CIs were calculated to assess injury risks. Soldiers who scored ≤14 were at a greater risk for injuries compared with those who scored >14 using the composite score for overuse injuries (RR, 1.84; 95% CI, 1.63-2.09), traumatic injuries (RR, 1.26; 95% CI, 1.03-1.54), and any injury (RR, 1.60; 95% CI, 1.45-1.77). When controlling for other known injury risk factors, multivariate logistic regression analysis identified poor FMS performance (OR [score ≤14/19-21], 2.00; 95% CI, 1.42-2.81) as an independent risk factor for injuries. A cut point of ≤14 registered low measures of predictive value for all 3 injury types (sensitivity, 28%-37%; PPV, 19%-52%; AUC, 54%-61%). Shifting the injury risk cut point of ≤14 to the optimal cut points indicated by the ROC did not appreciably improve sensitivity or the PPV. Although poor FMS performance was associated with a higher risk of injuries, it displayed low sensitivity, PPV, and AUC. On the basis of these findings, the use of the FMS to screen for the injury risk is not recommended in this population because of the low predictive value and misclassification of the

  2. Aplikasi Npv At Risk dalam Analisis Kelayakan Finansial Budidaya Jamur Tiram Putih di Kabupaten Bogor Jawa Barat

    OpenAIRE

    Sarianti, Tintin; Sasongko, Hendro; Ratnawati, Anny

    2008-01-01

    The purpose of this study where to analyze white oyster mushroom farming activity in Sub-Province of Bogor, to analyze financial feasibility of white oyster mushroom farming activity for high and low land in Sub-Province of Bogor by NPV at Risk Method and to analyze the switching value for the changes of cost and benefit in white oyster mushroom farming activity. The data were collected from 6 farmer living in high and low land in Sub-Province of Bogor. The NPV at risk model and switching ...

  3. Current nonclinical testing paradigm enables safe entry to First-In-Human clinical trials: The IQ consortium nonclinical to clinical translational database.

    Science.gov (United States)

    Monticello, Thomas M; Jones, Thomas W; Dambach, Donna M; Potter, David M; Bolt, Michael W; Liu, Maggie; Keller, Douglas A; Hart, Timothy K; Kadambi, Vivek J

    2017-11-01

    The contribution of animal testing in drug development has been widely debated and challenged. An industry-wide nonclinical to clinical translational database was created to determine how safety assessments in animal models translate to First-In-Human clinical risk. The blinded database was composed of 182 molecules and contained animal toxicology data coupled with clinical observations from phase I human studies. Animal and clinical data were categorized by organ system and correlations determined. The 2×2 contingency table (true positive, false positive, true negative, false negative) was used for statistical analysis. Sensitivity was 48% with a 43% positive predictive value (PPV). The nonhuman primate had the strongest performance in predicting adverse effects, especially for gastrointestinal and nervous system categories. When the same target organ was identified in both the rodent and nonrodent, the PPV increased. Specificity was 84% with an 86% negative predictive value (NPV). The beagle dog had the strongest performance in predicting an absence of clinical adverse effects. If no target organ toxicity was observed in either test species, the NPV increased. While nonclinical studies can demonstrate great value in the PPV for certain species and organ categories, the NPV was the stronger predictive performance measure across test species and target organs indicating that an absence of toxicity in animal studies strongly predicts a similar outcome in the clinic. These results support the current regulatory paradigm of animal testing in supporting safe entry to clinical trials and provide context for emerging alternate models. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Surface-Enhanced Raman Scattering of MEH-PPV on Gold and Silver Nanoparticles

    Directory of Open Access Journals (Sweden)

    Beatriz R. Moraes

    2018-01-01

    Full Text Available The interaction of poly[2-methoxy-5-(2-ethylhexyloxy-1,4-phenylenevinylene] (MEH-PPV with Au or Ag nanospheres, Au nanostars, and Ag nanoprisms was investigated using surface-enhanced Raman scattering (SERS. The SERS investigation showed that adsorption of MEH-PPV strongly depends on the nature of the nanoparticle surface. On gold nanostars that present a thick layer of capping polymer, SERS spectrum is only observed in relatively concentrated MEH-PPV solution (1 mmol L−1. On the other hand, Au and Ag nanospheres present SERS spectra down to 10−6 mol L−1 and no chemical interaction of MEH-PPV and metal surface is observed. The spectra of MEH-PPV on Ag nanoprisms with PVP as stabilizing agent suggest that the capping polymer induces a planar conformation of MEH-PPV and consequently an increase of conjugation length. These results give support for the application of MEH-PPV on optoelectronics in which interfacial effects are critical in the device efficiency and stability.

  5. Comparison of the HEART and TIMI Risk Scores for Suspected Acute Coronary Syndrome in the Emergency Department.

    Science.gov (United States)

    Sun, Benjamin C; Laurie, Amber; Fu, Rongwei; Ferencik, Maros; Shapiro, Michael; Lindsell, Christopher J; Diercks, Deborah; Hoekstra, James W; Hollander, Judd E; Kirk, J Douglas; Peacock, W Frank; Anantharaman, Venkataraman; Pollack, Charles V

    2016-03-01

    The emergency department evaluation for suspected acute coronary syndrome (ACS) is common, costly, and challenging. Risk scores may help standardize clinical care and screening for research studies. The Thrombolysis in Myocardial Infarction (TIMI) and HEART are two commonly cited risk scores. We tested the null hypothesis that the TIMI and HEART risk scores have equivalent test characteristics. We analyzed data from the Internet Tracking Registry of Acute Coronary Syndromes (i*trACS) from 9 EDs on patients with suspected ACS, 1999-2001. We excluded patients with an emergency department diagnosis consistent with ACS, or without sufficient data to calculate TIMI and HEART scores. The primary outcome was 30-day major adverse cardiovascular events, including all-cause death, acute myocardial infarction, and urgent revascularization. We describe test characteristics of the TIMI and HEART risk scores. The study cohort included 8255 patients with 508 (6.2%) 30-day major adverse cardiovascular events. Receiver operating curve and reclassification analyses favored HEART [c statistic: 0.753, 95% confidence interval (CI): 0.733-0.773; continuous net reclassification improvement: 0.608, 95% CI: 0.527-0.689] over TIMI (c statistic: 0.678, 95% CI: 0.655-0.702). A HEART score 0-3 [negative predictive value (NPV) 0.982, 95% CI: 0.978-0.986; positive predictive value (PPV) 0.103, 95% CI: 0.094-0.113; likelihood ratio (LR) positive 1.76; LR negative 0.28] demonstrates similar or superior NPV/PPV/LR compared with TIMI = 0 (NPV 0.978, 95% CI: 0.971-0.983; PPV 0.077, 95% CI: 0.071-0.084; LR positive 1.28; LR negative 0.35) and TIMI = 0-1 (NPV 0.963, 95% CI: 0.958-0.968; PPV 0.102, 95% CI: 0.092-0.113; LR positive 1.73; LR negative 0.58). The HEART score has better discrimination than TIMI and outperforms TIMI within previously published "low-risk" categories.

  6. Mammographic findings predicting an extensive intraductal component in early stage invasive breast cancer : analysis on microcalcification

    International Nuclear Information System (INIS)

    Kim, Jeong Ah; Kim, Mi Hye; Lee, Mi Kyung; Oh, Ki Keun; Kim, Eun Kyung

    2000-01-01

    To analyze the mammographic findings of extensive intraductal component (EIC)-positive early invasive breast carcinoma and to determine the mammographic features which predict an EIC positivity in an invasive carcinoma. The mammographic and pathologic findings in 71 patients aged 34-79 (mean 50) years in whom stage I or II invasive breast carcinoma had been diagnosed were retrospectively analysed. The mammographic findings were assigned to one of three groups: mass, mass with microcalcification, or microcalcification only. The shape and distribution of a calcification were classified according to the BI-RADS lexicon, and its extent was classified as either more or less than 3 cm. To detect the presence or absence of EIC and the type of ductal carcinoma in situ (DCIS), the findings were re-examined by means of slide mappings. Twenty-eight of 71 patients (39%) showed ECI positivity. The mammographic findings of EIC-positive invasive cancer (n=3D28) were mass with microcalcification (n=3D14), microcalcification only (n=3D7) and mass only (n=3D7). The mammographic finding which predicted EIC positivity was mass with microcalcification (PPV:0.67, NPV:0.33, p=3D0.02). A mammographic of mass only (n=3D39) showed a significantly high negative predictive value for EIC positivity. (PPV 0.18, NPV 0.82, P less than 0.01). A comparison of cases with or without calcification showed that those with microcalcifications (n=3D32) showed a significantly high PPV of 0.66 (NPV:0.34, p less than 0.01) while those without calcification (n=3D39) showed a significantly high NPV of 0.82 (PPV:0.18, p less than 0.01). There were no significant differences in positive predictive values for EIC between the shape, distribution and extent of calcifications. Whenever microcalcification with or without mass is seen on mammographs obtained during early breast cancer, we can predict EIC-positivity, regardless of shape or distribution according to the BI-RADS lexicon. (author)

  7. Performance of syndromic management for the detection and treatment of genital Chlamydia trachomatis, Neisseria gonorrhoeae and Trichomonas vaginalis among women attending antenatal, well woman and sexual health clinics in Papua New Guinea: a cross-sectional study.

    Science.gov (United States)

    Vallely, Lisa M; Toliman, Pamela; Ryan, Claire; Rai, Glennis; Wapling, Johanna; Gabuzzi, Josephine; Allen, Joyce; Opa, Christine; Munnull, Gloria; Kaima, Petronia; Kombuk, Benny; Kumbia, Antonia; Kombati, Zure; Law, Greg; Kelly-Hanku, Angela; Wand, Handan; Siba, Peter M; Mola, Glen D L; Kaldor, John M; Vallely, Andrew J

    2017-12-29

    Papua New Guinea (PNG) has among the highest estimated prevalences of genital Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) and Trichomonas vaginalis (TV) of any country in the Asia-Pacific region. Diagnosis and treatment of these infections have relied on the WHO-endorsed syndromic management strategy that uses clinical presentation without laboratory confirmation to make treatment decisions. We evaluated the performance of this strategy in clinical settings in PNG. Women attending antenatal (ANC), well woman (WWC) and sexual health (SHC) clinics in four provinces were invited to participate, completed a face-to-face interview and clinical examination, and provided genital specimens for laboratory testing. We estimated the performance characteristics of syndromic diagnoses against combined laboratory diagnoses. 1764 women were enrolled (ANC=765; WWC=614; SHC=385). The prevalences of CT, NG and TV were highest among women attending ANC and SHC. Among antenatal women, syndromic diagnosis of sexually transmitted infection had low sensitivity (9%-21%) and positive predictive value (PPV) (7%-37%), but high specificity (76%-89%) and moderate negative predictive value (NPV) (55%-86%) for the combined endpoint of laboratory-confirmed CT, NG or TV. Among women attending WWC and SHC, 'vaginal discharge syndrome' had moderate to high sensitivity (72%-78%) and NPV (62%-94%), but low specificity (26%-33%) and PPV (8%-38%). 'Lower abdominal pain syndrome' had low sensitivity (26%-41%) and PPV (8%-23%) but moderate specificity (66%-68%) and high NPV (74%-93%) among women attending WWC, and moderate-high sensitivity (67%-79%) and NPV (62%-86%) but low specificity (26%-28%) and PPV (14%-33%) among SHC attendees. The performance of syndromic management for the detection and treatment of genital chlamydia, gonorrhoea and trichomonas was poor among women in different clinical settings in PNG. New diagnostic strategies are needed to control these infections and to prevent

  8. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    International Nuclear Information System (INIS)

    Iannicelli, Elsa; Di Renzo, Sara; Ferri, Mario; Pilozzi, Emanuela; Di Girolamo, Marco; Sapori, Alessandra; Ziparo, Vincenzo; David, Vincenzo

    2014-01-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting

  9. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Iannicelli, Elsa; Di Renzo, Sara [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ferri, Mario [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Pilozzi, Emanuela [Department of Clinical and Molecular Sciences, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Di Girolamo, Marco; Sapori, Alessandra [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ziparo, Vincenzo [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); David, Vincenzo [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy)

    2014-07-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting.

  10. The performance characteristics of prostate-specific antigen and prostate-specific antigen density in Chinese men.

    Science.gov (United States)

    Teoh, Jeremy Yc; Yuen, Steffi Kk; Tsu, James Hl; Wong, Charles Kw; Ho, Brian Sh; Ng, Ada Tl; Ma, Wai-Kit; Ho, Kwan-Lun; Yiu, Ming-Kwong

    2017-01-01

    We investigated the performance characteristics of prostate-specific antigen (PSA) and PSA density (PSAD) in Chinese men. All Chinese men who underwent transrectal ultrasound-guided prostate biopsy (TRUS-PB) from year 2000 to 2013 were included. The receiver operating characteristic (ROC) curves for both PSA and PSAD were analyzed. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) at different cut-off levels were calculated. A total of 2606 Chinese men were included. For the ROC, the area under curve was 0.770 for PSA (P specificity of 14.1%, PPV of 29.5%, and NPV of 86.9%; PSAD of 0.12 ng ml-1 cc-1 had sensitivity of 94.5%, specificity of 26.6%, PPV of 32.8%, and NPV of 92.7%. On multivariate logistic regression analyses, PSA cut-off at 4.5 ng ml-1 (OR 1.61, 95% CI 1.05-2.45, P= 0.029) and PSAD cut-off at 0.12 ng ml-1 cc-1 (OR 6.22, 95% CI 4.20-9.22, Pprostate cancer detection on TRUS-PB. In conclusion, the performances of PSA and PSAD at different cut-off levels in Chinese men were very different from those in Caucasians. PSA of 4.5 ng ml-1 and PSAD of 0.12 ng ml-1 cc-1 had near 95% sensitivity and were significant predictors of prostate cancer detection in Chinese men.

  11. Efficacy of in-house fluorescent stain for fungus

    Directory of Open Access Journals (Sweden)

    K. R. L. Surya Kirani

    2017-01-01

    Full Text Available Context: Mycotic infections are gaining importance in the present day medicine, and definite demonstration of fungus is essential for diagnosis. Small numbers of organisms in the smear can be identified by fluorescence microscopy. Calcofluor white (CFW fluorescent stain is a textile brightener mixed with Evans blue. It is expensive and not easily available. Aims: (1 To assess the efficacy of in-house CFW fluorescent stain for fungus in relation to conventional CFW stain, histopathology, and culture. (2 To determine sensitivity, specificity, negative predictive value (NPV, and positive predictive value (PPV with culture as gold standard. Settings and Design: One hundred cases of suspected dermatophytosis and 15 cases of systemic mycosis were included in the study. Subjects and Methods: The local whitener Ranipal is added with Robin blue, another brightener, and was used to stain teased fungal cultures. Skin, hair, and nails require pretreatment with potassium hydroxide (KOH. Biopsy slides require deparaffinization and pretreatment with KOH before staining. Conventional calcofluor stain, histopathology, and culture were done. Statistical Analysis Used: Statistical analysis was performed using sensitivity, specificity, NPV, and PPV. Results: The results are consistently comparable with conventional stain. The sensitivity was 100%, specificity was 93.3%, NPV was 100%, and PPV was 85.7%. It is also cost effective when compared to commercial stains. Conclusions: In-house stain can be used for screening of fungus in direct samples, biopsies as alternative in resource-constrained laboratories.

  12. Modeling charge transport properties of cyano-substituted PPV

    International Nuclear Information System (INIS)

    Correia, Helena M.G.; Ramos, Marta M.D.

    2003-01-01

    In recent years, poly (p-phenylenevinylene) (PPV) and its derivatives have attracted much interest due to their applications in light-emitting diodes (LEDs). One of the issues that determine device performance is the transport of charge carriers along the polymer strands. For that reason, we investigate the influence of cyano substitution on geometry and electronic behaviour of PPV chains using self-consistent quantum molecular dynamics simulations. Our results suggest that substitution by cyano groups induce distortion in the PPV chains and a charge rearrangement among the polymer atoms. Specifically addressed is the issue concerning estimates of charge (electron and hole) mobility by computer experiments. Significant differences have been found both in the strength of the electric field needed to move positive and negative charge carriers along the polymer chain as well as in charge mobility

  13. Enhancement of the solubility, thermal stability, and electronic properties of carbon nanotubes functionalized with MEH-PPV: A combined experimental and computational study

    International Nuclear Information System (INIS)

    Prajongtat, P.; Suramitr, S.; Hannongbua, S.; Gleeson, M.P.; Mitsuke, K.

    2013-01-01

    Multi-walled carbon nanotubes (MWCNTs) functionalized with poly[2-methoxy-5-(2′-ethylhexyloxy)-1,4-phenylenevinylene] (MWCNT-f-MEH-PPV) nanocomposites were successfully prepared by employing a “grafting from” approach. The content of the functionalizing MEH-PPV in the composites was observed as 76 wt.%. Compared with pristine MWCNTs (p-MWCNT), the aqueous solubility and thermal stability of the former are significantly enhanced. The effect of covalently and non-covalently functionalized nanotubes on dye-sensitized solar cell performance was also studied. Solar cells were successfully fabricated from isolated MEH-PPV, p-MWCNT/MEH-PPV, and MWCNT-f-MEH-PPV/MEH-PPV counter electrodes. The devices based on a MWCNT-f-MEH-PPV/MEH-PPV counter electrode demonstrated the best photovoltaic performance as observed by higher J SC, V OC, and fill factor (FF) values. The experimental phenomena can be explained by quantum-chemical calculations: Charge transfer from MEH-PPV oligomers to nanotubes is greater when covalently functionalized compared with non-covalently functionalized. This suggests that the improvement in the photovoltaic parameters of the cells containing covalently functionalized nanotubes results not only from the higher concentration present in the nanotube films of the counter electrode, but also from the greater electron delocalization between the oligomers and nanotubes. (author)

  14. APLIKASI NPV AT RISK DALAM ANALISIS KELAYAKAN FINANSIAL BUDIDAYA JAMUR TIRAM PUTIH DI KABUPATEN BOGOR JAWA BARAT

    OpenAIRE

    Tintin Sarianti; Hendro Sasongko; Anny Ratnawati

    2011-01-01

    The purpose of this study where to analyze white oyster mushroom farming activity in Sub-Province of Bogor, to analyze financial feasibility of  white oyster mushroom farming activity for high and low land in Sub-Province of Bogor by NPV at Risk Method and to analyze the switching value for the changes of cost and benefit in  white oyster mushroom farming activity.  The data were collected from 6 farmer living in high and low land in Sub-Province of Bogor. The NPV at risk model and switching ...

  15. Evaluation of PCA3 and multiparametric MRI’s: collective benefits before deciding initial prostate biopsy for patients with PSA level between 3-10ng/mL

    Directory of Open Access Journals (Sweden)

    Sezgin Okcelik

    2016-06-01

    Full Text Available ABSTRACT Objective To analyze the contribution of multiparametric MRI and PCA3 assay, pre- decision of initial biopsy in PSA level between 3-10 ng/mL patients with normal digital rectal examination(DRE. Materials and Methods PSA level 3-10 ng/mL ,patients, with normal DRE results and no previous prostate biopsy history, were included in this study. Each patient underwent multiparametric MRI one week before biopsy. Urine sample taking for PCA3 examination preceded the biopsy. Systematic and targeted biopsies were conducted. Patients with high PSA levels were seperated into two groups as: high PCA3 scored and low PCA3 scored. Then each group was divided into two sub-groups as: MRI lesion positive and negative. Tumor incidence, positive predictive values(PPV and negative predictive values(NPV were calculated. Results 53 patients were included between February 2013 and March 2014.Mean age 61.22 ± 1.06. Mean PSA value 5.13 ± 0.19 ng / mL. Mean PCA3 score 98.01 ± 23.13 and mean prostate size was 48.96 ± 2.67 grams. Fourty nine patients had both PCA3 score and multiparametric MRI. The PCA3’s PPV value was 58.33%. If multiparametric MRI lesions are added to high PCA3 scores , the PPV appears to elevate to 91.66%. NPV of PCA3 was 96%. NPV was 95% when there was no lesion in the multiparametric MRI with low PCA3 scores. Sensitivity was 91.66% , specificity was 95% respectively. Conclusion Adding multimetric MRI can also support biopsy decision for patients with high PCA3 value. When PCA3 value is low, patients can be survailled without any need to take a MRI.

  16. Colloidal behavior of Np(V) in aqueous systems

    International Nuclear Information System (INIS)

    Zhao Xin; Zhang Yingjie; Wei Liansheng; Lin Zhangji

    2004-01-01

    The speciation of Np(V) in solutions is measured by means of FT-Raman spectrometer. The formation of colloid of Np(V) in aqueous solutions is studied with the variation of pH(2-12), ionic strength (0.01 mol/L, 0.1 mol/L, 1.0 mol/L), storage time (6h, 30h, 1 week, 6 weeks) and neptunium concentration. The adsorption behavior of Np(V) on granite and its rock-forming minerals (quartz, microcline, albite, biotite and hornblende) is also studied in an aqueous phase of artificial ground water. The experiments are performed at ambient temperature. Experimental results show that a small fraction of Np removed from the solution is adsorbed on the walls of container at the pH above 6 due to the formation of colloid of Np. The formation of colloid of Np depends on its hydrolytic extent, ionic strength, and storage time. The adsorption of Np on granite and the individual mineral depends strongly on the formation of the colloids with the variation of pH in solutions. (author)

  17. Predictive values of early rest/24 hour delay Tl-201 perfusion SPECT for wall motion improvement in patients with acute myocardial infarction after reperfusion

    International Nuclear Information System (INIS)

    Hyun, In Young; Kwan, June

    1998-01-01

    We studied early rest/24 hour delay Tl-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Among 17 patients (male/female=11/6, age: 59±13) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay:11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest Tl-201 perfusion SPECT less then 6 hours after reperfusion and delay Tl-201 perfusion SPECT next day. Tl-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest Tl-201 uptake ≤2 or combination of rest Tl-201 uptake ≤2 or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ≥1 grade in follow up echo compared with the baseline values. Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest Tl-201uptake were 99%, and 54%.PPV and NPV of rest Tl-201 uptake were 100% and 52% respectively. Predictive values of comibination of rest Tl-201 uptake and late reversibility were not significantly different compared with predictive values of rest Tl-201 uptake only. We conclude that early Tl-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative

  18. Diagnostic value of pelvic enthesitis on MRI of the sacroiliac joints in spondyloarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Jans, L.; Langenhove, C. van; Lambrecht, V.; Verstraete, K. [Ghent University Hospital, Department of Radiology and Medical Imaging, Gent (Belgium); Praet, L. van; Carron, P.; Elewaut, D.; Bosch, F.V. den [Ghent University Hospital, Department of Rheumatology, Gent (Belgium); Jaremko, J.L. [University of Alberta Hospital, Department of Radiology, Edmonton, Alberta (Canada)

    2014-04-15

    To determine the prevalence and diagnostic value of pelvic enthesitis on MRI of the sacroiliac (SI) joints in spondyloarthritis (SpA). A retrospective study in 444 patients aged 17-45 years old with MRI of the SI joints and with clinically suspected sacroiliitis was performed. Patients were classified as having SpA if they fulfilled the Assessment of Spondyloarthritis International Society (ASAS) criteria. Pelvic enthesitis on MRI was correlated with the final diagnosis. Sensitivity, specificity, positive and negative likelihood ratio (LR) and predictive values (PV) of pelvic enthesitis for the diagnosis of SpA were calculated. MRI showed pelvic enthesitis in 24.4 % of patients with SpA and in 7.1 % of patients without SpA. Presence of any enthesitis had sensitivity, specificity, LR+, LR-, PPV and NPV of 24.4 %, 92.9 %, 3.45, 0.81, 69.4 % and 65.2 % for the diagnosis of SpA, respectively. The most commonly affected entheses were the longitudinal ligament insertion (4.5 %), the retroarticular ligaments (4.1 %) and the pubic symphysis (4.1 %). The sites of enthesitis with the highest PPV for SpA were the iliac crest/wing (85.7 %) and the retroarticular ligaments (81.3 %). Nearly one fourth of SpA patients with suspected sacroiliitis showed pelvic enthesitis on MRI. Such pelvic enthesitis has a high specificity for the diagnosis of spondyloarthritis. (orig.)

  19. Operative characteristic of the myocardial perfusion of repose in the evaluation of the thoracic pain in urgencies

    International Nuclear Information System (INIS)

    Merlano, Sonia; Murgueitio, Ramon; Rodriguez, Edgard; Carvajal, Andres; Suarez, Martin

    2000-01-01

    Conventional emergency department testing strategies for patients with chest pain often provide equivocal diagnosis of coronary artery disease. This study was conducted in order to determine the sensitivity, specificity, positive predictive value (PPV) negative predictive value (NPV) and negative likelihood ratio (LR-) of the myocardial perfusion imaging with single photon emission computed tomography (SPECT) imaging at rest

  20. Benefit of cerebrospinal fluid spectrophotometry in the assessment of CT scan negative suspected subarachnoid haemorrhage: a diagnostic accuracy study.

    Science.gov (United States)

    Hann, Angus; Chu, Kevin; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2015-01-01

    This study aimed to determine if performing cerebrospinal fluid spectrophotometry in addition to visual inspection detects more ruptured cerebral aneurysms than performing cerebrospinal fluid visual inspection alone in patients with a normal head CT scan but suspected of suffering an aneurysmal subarachnoid haemorrhage (SAH). We performed a single-centre retrospective study of patients presenting to the emergency department of a tertiary hospital who underwent both head CT scan and lumbar puncture to exclude SAH. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of an approach utilising both spectrophotometry and visual inspection (combined approach) was compared to visual inspection alone. A total of 409 patients (mean age 37.8 years, 56.2% female) were recruited and six (1.5%) had a cerebral aneurysm on angiography. The sensitivity of visual inspection was 50% (95% confidence interval [CI]: 12.4-82.6%), specificity was 99% (95% CI: 97.5-99.7%), PPV was 42.9% (95% CI: 10.4-81.3%) and NPV was 99.2% (95% CI: 97.8-99.8%). The combined approach had a sensitivity of 100% (95% CI: 54.1-100%), specificity of 79.7% (95% CI: 75.4-83.5%), PPV of 6.8% (95% CI: 2.6-14.3%) and a NPV of 100% (95% CI: 98.8-100%). The sensitivity of the combined approach was not significantly different to that of visual inspection alone (p=0.25). Visual inspection had a significantly higher specificity than the combined approach (p<0.01). The combined approach detected more cases of aneurysmal SAH than visual inspection alone, however the difference in sensitivity was not statistically significant. Visual xanthochromia should prompt angiography because of a superior specificity and PPV. Due to its reduced sensitivity, caution should be applied when using only visual inspection of the supernatant. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  1. Determination of the diagnostic x-ray tube practical peak voltage (PPV) from average or average peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hourdakis, C J, E-mail: khour@gaec.gr [Ionizing Radiation Calibration Laboratory-Greek Atomic Energy Commission, PO Box 60092, 15310 Agia Paraskevi, Athens, Attiki (Greece)

    2011-04-07

    The practical peak voltage (PPV) has been adopted as the reference measuring quantity for the x-ray tube voltage. However, the majority of commercial kV-meter models measure the average peak, U-bar{sub P}, the average, U-bar, the effective, U{sub eff} or the maximum peak, U{sub P} tube voltage. This work proposed a method for determination of the PPV from measurements with a kV-meter that measures the average U-bar or the average peak, U-bar{sub p} voltage. The kV-meter reading can be converted to the PPV by applying appropriate calibration coefficients and conversion factors. The average peak k{sub PPV,kVp} and the average k{sub PPV,Uav} conversion factors were calculated from virtual voltage waveforms for conventional diagnostic radiology (50-150 kV) and mammography (22-35 kV) tube voltages and for voltage ripples from 0% to 100%. Regression equation and coefficients provide the appropriate conversion factors at any given tube voltage and ripple. The influence of voltage waveform irregularities, like 'spikes' and pulse amplitude variations, on the conversion factors was investigated and discussed. The proposed method and the conversion factors were tested using six commercial kV-meters at several x-ray units. The deviations between the reference and the calculated - according to the proposed method - PPV values were less than 2%. Practical aspects on the voltage ripple measurement were addressed and discussed. The proposed method provides a rigorous base to determine the PPV with kV-meters from U-bar{sub p} and U-bar measurement. Users can benefit, since all kV-meters, irrespective of their measuring quantity, can be used to determine the PPV, complying with the IEC standard requirements.

  2. Diagnostic value of pleural fluid adenosine deaminase activity in tuberculosis pleurisy

    Directory of Open Access Journals (Sweden)

    Abbas ali Niazi

    2009-09-01

    Full Text Available Background: Diagnosis of tuberculosis pleurisies is difficult because of its nonspecific clinical presentation and insufficient traditional diagnostic methods. We investigated the use of adenosine deaminase (ADA activity in tuberculosis pleurisies. Methods: A number of 85 patients were analyzed with exudative pleural effusions. Using the ROC curve, we determined the optimal cutoff for TB pleurisy. Results: A number of 58 exudative samples were nontuberculous (non-TB and 27 were tuberculosis (TB. There was statistically significant difference (p<0.0001 between the means of pleural fluid ADA levels among the TB and non-TB populations. The prevalence of TB pleurisy in the studied population was 31%. Using the cutoff point equal to 35 for diagnosing TB effusions the sensitivity and specificity 70.3% and 91.3%, respectively. The positive predictive value (PPV was 79.1% and the negative predictive value (NPV was 86.8%. A pleural fluid ADA value <19 IU/L suggests that a tuberculosis effusion is highly unlikely. Conclusion: Pleural fluid total ADA assay is a sensitive and specific test suitable for rapid diagnosis of TB pleurisy.

  3. Optimization of diagnosis and follow-up of differentiated thyroid cancer

    NARCIS (Netherlands)

    Kist, J.W.

    2016-01-01

    We studied the value of thyroid nodule (TN) elastography in determining whether a TN is malignant. The results of twenty studies, compromising 3973 nodules, were included. The results showed a pooled sensitivity and specificity of 85% and 80%, respectively. The pooled NPV and PPV were 97% and 40%.

  4. Identification and genomic characterization of a novel porcine parvovirus (PPV6) in China.

    Science.gov (United States)

    Ni, Jianqiang; Qiao, Caixia; Han, Xue; Han, Tao; Kang, Wenhua; Zi, Zhanchao; Cao, Zhen; Zhai, Xinyan; Cai, Xuepeng

    2014-12-02

    Parvoviruses are classified into two subfamilies based on their host range: the Parvovirinae, which infect vertebrates, and the Densovirinae, which mainly infect insects and other arthropods. In recent years, a number of novel parvoviruses belonging to the subfamily Parvovirinae have been identified from various animal species and humans, including human parvovirus 4 (PARV4), porcine hokovirus, ovine partetravirus, porcine parvovirus 4 (PPV4), and porcine parvovirus 5 (PPV5). Using sequence-independent single primer amplification (SISPA), a novel parvovirus within the subfamily Parvovirinae that was distinct from any known parvoviruses was identified and five full-length genome sequences were determined and analyzed. A novel porcine parvovirus, provisionally named PPV6, was initially identified from aborted pig fetuses in China. Retrospective studies revealed the prevalence of PPV6 in aborted pig fetuses and piglets(50% and 75%, respectively) was apparently higher than that in finishing pigs and sows (15.6% and 3.8% respectively). Furthermore, the prevalence of PPV6 in finishing pig was similar in affected and unaffected farms (i.e. 16.7% vs. 13.6%-21.7%). This finding indicates that animal age, perhaps due to increased innate immune resistance, strongly influences the level of PPV6 viremia. Complete genome sequencing and multiple alignments have shown that the nearly full-length genome sequences were approximately 6,100 nucleotides in length and shared 20.5%-42.6% DNA sequence identity with other members of the Parvovirinae subfamily. Phylogenetic analysis showed that PPV6 was significantly distinct from other known parvoviruses and was most closely related to PPV4. Our findings and review of published parvovirus sequences suggested that a novel porcine parvovirus is currently circulating in China and might be classified into the novel genus Copiparvovirus within the subfamily Parvovirinae. However, the clinical manifestations of PPV6 are still unknown in that the

  5. Evaluation of a new rapid lateral flow chromatography test for the diagnosis of Helicobacter Pylori

    International Nuclear Information System (INIS)

    Kaklikkaya, N.; Dinc, U.; Dabanca, Pinar A.; Aydin, F.; Erturk, M.; Akdogan, Remzi A.; Ozgur, O.; Uzun, Dogan Y.; Gungor, E.; Arslan, M.; Cobanoglu, U.

    2006-01-01

    The rapid, simple and non-invasive diagnosis of Helicobacter pylori (H. pylori) infection is important in implementing chemotherapy in appropriate manner, and in assessing persistent H. pylori infection after eradication therapy. The Immuno Card STAT HpSA kit (Meridian Bioscience, Europe) is a lateral flow chromatography test which utilizes a monoclonal anti-H. pylori antibody. In this study, we investigated the usefulness of the ImmunoCard STAT HpSA test before and after eradication therapy on patients referred to undergo upper gastrointestinal endoscopy. Sixty-five consecutive patients who were referred to undergo upper gastrointestinal endoscopy at the Department of Gastroenterology, Karadeniz Technical University Medical School, Turkey between February and August 2005 were included in this study. The ImmunoCard STAT HpSA was compared with 4 invasive tests (histology, gram staining, rapid urease test, and culture). The reference method was defined as positive when 2 of the 4 invasive tests were positive. A negative H. pylori status was considered when all 4 tests present concordant negative results. Overall, the ImmunoCard STAT HpSA test had 77.8% sensitivity, 79.3% specificity, 82.4% positive predictive value (PPV) and 74.2% negative predictive value (NPV) in all patients. With regard to pre-treatment values, the sensitivity was 70.6%, specificity 70.6%, PPV 100% and NPV 100% while on post-treatment group the sensitivity was 84.2%, specificity 64.7%, PPV 72.7% and NPV 78.6%. Our results indicate that the ImmunoCard STAT HpSA test is a rapid, simple, and helpful procedure not only to determine H. pylori infection but also to assess the success of eradication therapy. (author)

  6. Comparison of Swirl Sign and Black Hole Sign in Predicting Early Hematoma Growth in Patients with Spontaneous Intracerebral Hemorrhage.

    Science.gov (United States)

    Xiong, Xin; Li, Qi; Yang, Wen-Song; Wei, Xiao; Hu, Xi; Wang, Xing-Chen; Zhu, Dan; Li, Rui; Cao, Du; Xie, Peng

    2018-01-29

    BACKGROUND Early hematoma growth is associated with poor outcome in patients with spontaneous intracerebral hemorrhage (ICH). The swirl sign (SS) and the black hole sign (BHS) are imaging markers in ICH patients. The aim of this study was to compare the predictive value of these 2 signs for early hematoma growth. MATERIAL AND METHODS ICH patients were screened for the appearance of the 2 signs within 6 h after onset of symptoms. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the 2 signs in predicting early hematoma growth were assessed. The accuracy of the 2 signs in predicting early hematoma growth was analyzed by receiver-operator analysis. RESULTS A total of 200 patients were enrolled in this study. BHS was found in 30 (15%) patients, and SS was found in 70 (35%) patients. Of the 71 patients with early hematoma growth, BHS was found on initial computed tomography scans in 24 (33.8%) and SS in 33 (46.5%). The sensitivity, specificity, PPV, and NPV of BHS for predicting early hematoma growth were 33.8%, 95.3%, 80.0%, and 72.0%, respectively. The sensitivity, specificity, PPV, and NPV of SS were 46.5%, 71.3%, 47.0%, and 71.0%, respectively. The area under the curve was 0.646 for BHS and 0.589 for SS (P=0.08). Multivariate logistic regression showed that presence of BHS is an independent predictor of early hematoma growth. CONCLUSIONS The Black hole sign seems to be good predictor for hematoma growth. The presence of swirl sign on admission CT does not independently predict hematoma growth in patients with ICH.

  7. An NPV and AC Analysis of a Stochastic Inventory System with Joint Manufacturing and Remanufacturing

    NARCIS (Netherlands)

    E.A. van der Laan (Erwin)

    2000-01-01

    textabstractWhile the net present value (NPV) approach is widely accepted as the right framework for studying production and inventory control systems, average cost (AC) models are more widely used. For the well known EOQ model it can be veri_ed that (under certain conditions) the AC approach gives

  8. Quantitative contrast-enhanced harmonic EUS in differential diagnosis of focal pancreatic masses (with videos)

    DEFF Research Database (Denmark)

    Săftoiu, Adrian; Vilmann, Peter; Dietrich, Christoph F

    2015-01-01

    BACKGROUND: The role of EUS with contrast agents can be expanded through the use of time-intensity curve (TIC) analysis and computer-aided interpretation. OBJECTIVE: To validate the use of parameters derived from TIC analysis in an artificial neural network (ANN) classification model designed......-guided FNA (EUS-FNA), TIC analysis, and ANN processing. MAIN OUTCOME MEASUREMENTS: Sensitivity, specificity, positive and negative predictive values (PPV, NPV) for EUS-FNA, CEH-EUS, and the ANN. RESULTS: After excluding all of the recordings that did not meet the technical and procedural criteria, 112 cases...... rise time, mean transit time, and time to peak. For the ANN, sensitivity was 94.64%, specificity 94.44%, PPV 97.24%, and NPV 89.47%. LIMITATIONS: Only PC and CP lesions were included. CONCLUSION: Parameters obtained through TIC analysis can differentiate between PC and CP cases and can be used...

  9. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Tadros, Anthony S.; Huang, Brady K. [University of California, Department of Radiology, San Diego, CA (United States); Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan [Scripps Clinic, Department of Orthopedic Surgery, La Jolla, CA (United States); Chang, Eric Y. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California, Department of Radiology, San Diego, CA (United States)

    2015-09-15

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  10. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    Science.gov (United States)

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  11. Are screening instruments valid for psychotic-like experiences? A validation study of screening questions for psychotic-like experiences using in-depth clinical interview.

    LENUS (Irish Health Repository)

    Kelleher, Ian

    2012-02-01

    Individuals who report psychotic-like experiences are at increased risk of future clinical psychotic disorder. They constitute a unique "high-risk" group for studying the developmental trajectory to schizophrenia and related illnesses. Previous research has used screening instruments to identify this high-risk group, but the validity of these instruments has not yet been established. We administered a screening questionnaire with 7 items designed to assess psychotic-like experiences to 334 adolescents aged 11-13 years. Detailed clinical interviews were subsequently carried out with a sample of these adolescents. We calculated sensitivity and specificity and positive predictive value (PPV) and negative predictive value (NPV) for each screening question for the specific symptom it enquired about and also in relation to any psychotic-like experience. The predictive power varied substantially between items, with the question on auditory hallucinations ("Have you ever heard voices or sounds that no one else can hear?") providing the best predictive power. For interview-verified auditory hallucinations specifically, this question had a PPV of 71.4% and an NPV of 90.4%. When assessed for its predictive power for any psychotic-like experience (including, but not limited to, auditory hallucinations), it provided a PPV of 100% and an NPV of 88.4%. Two further questions-relating to visual hallucinations and paranoid thoughts-also demonstrated good predictive power for psychotic-like experiences. Our results suggest that it may be possible to screen the general adolescent population for psychotic-like experiences with a high degree of accuracy using a short self-report questionnaire.

  12. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    International Nuclear Information System (INIS)

    Tadros, Anthony S.; Huang, Brady K.; Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan; Chang, Eric Y.

    2015-01-01

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  13. Ditection of coronary artery disease: accuracy of 64- slice computed tomography versus converntional invasive angiography

    Directory of Open Access Journals (Sweden)

    Taghizadeh M

    2008-11-01

    Full Text Available "nBackground: Multislice computed tomography (MSCT is a noninvasive method of detecting coronary artery disease (CAD. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT in daily practice, without patient selection. "nMethods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA. The CT system The mean time span between MSCT and QCA was 7.2±3.9 days. For the 64-MSCT, detection or exclusion of CAD, defined as one or more areas of >50% stenosis within major epicardial coronary arteries, the sensitivity, specificity, diagnostic accuracy, positive predictive value (PPV, and negative predictive value (NPV were evaluated both per patient and per segment. "nResults: Sixty-one of the 64 coronary CT angiograms (95% were of diagnostic image quality. QCA showed significant CAD in 64% (39/61 of the patients, with the other 36% (22/61 showing nonsignificant disease or no disease. Sensitivity, specificity, accuracy, PPV, and NPV of 64-MSCT per patient were 92%, 86%, 90%, 92% and 96%, respectively. By the per-segment analysis, 695 of 791 coronary artery segments were assessable (88%. Of these, 64-MSCT showed a sensitivity of 80%, specificity of 92%, accuracy of 90%, PPV of 65%, and NPV of 96%, respectively, in detecting CAD. "nConclusions: Both per patient and per segment analyses for coronary 64-MSCT showed a higher diagnostic accuracy than QCA. This suggests 64-MSCT should primarily be used for risk stratification on a per patient basis as a noninvasive gate-keeper diagnostic method.

  14. Are screening instruments valid for psychotic-like experiences? A validation study of screening questions for psychotic-like experiences using in-depth clinical interview.

    LENUS (Irish Health Repository)

    Kelleher, Ian

    2011-03-01

    Individuals who report psychotic-like experiences are at increased risk of future clinical psychotic disorder. They constitute a unique "high-risk" group for studying the developmental trajectory to schizophrenia and related illnesses. Previous research has used screening instruments to identify this high-risk group, but the validity of these instruments has not yet been established. We administered a screening questionnaire with 7 items designed to assess psychotic-like experiences to 334 adolescents aged 11-13 years. Detailed clinical interviews were subsequently carried out with a sample of these adolescents. We calculated sensitivity and specificity and positive predictive value (PPV) and negative predictive value (NPV) for each screening question for the specific symptom it enquired about and also in relation to any psychotic-like experience. The predictive power varied substantially between items, with the question on auditory hallucinations ("Have you ever heard voices or sounds that no one else can hear?") providing the best predictive power. For interview-verified auditory hallucinations specifically, this question had a PPV of 71.4% and an NPV of 90.4%. When assessed for its predictive power for any psychotic-like experience (including, but not limited to, auditory hallucinations), it provided a PPV of 100% and an NPV of 88.4%. Two further questions-relating to visual hallucinations and paranoid thoughts-also demonstrated good predictive power for psychotic-like experiences. Our results suggest that it may be possible to screen the general adolescent population for psychotic-like experiences with a high degree of accuracy using a short self-report questionnaire.

  15. Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification

    International Nuclear Information System (INIS)

    Lin, C.-J.; Hsu, J.-C.; Lai, Y.-J.; Wang, K.-L.; Lee, J.-Y.; Li, A.-H.; Chu, S.-H.

    2010-01-01

    Aim: To assess the ability of coronary angiography performed using dual-source computed tomography (DSCT) to evaluate coronary artery disease (CAD) in a population with unselected heart rates and extensive coronary calcification. Materials and methods: Forty-four patients at intermediate to high risk for CAD underwent both DSCT coronary angiography and invasive coronary angiography (ICA) within 30 days. No beta blockers were administered prior to imaging. Image quality and quantitatively stenosis of all coronary segments with a diameter ≥1.5 mm were accessed. Patients were stratified according to mean heart rate (<70 versus ≥70 bpm) and heart rate variability (<10 versus ≥10 bpm). DSCT detection of coronary stenosis by segment, vessel, and patient characteristics were compared to the reference standard of ICA. Results: Diagnostic accuracy for all patients was high regarding sensitivity (97%), positive predictive value (PPV, 84.2%), and negative predictive value (NPV, 83.3%) but low regarding specificity (45.5%) with a moderate interobserver agreement (Kappa = 0.50). The accuracy for vessel-based diagnosis was high regarding sensitivity (96.6%), specificity (80.8%), PPV (80.3%), and NPV (96.7%). The segment-based diagnostic results revealed a moderate interobserver agreement for image quality and sensitivity, specificity, PPV and NPV for all segments of 66.9, 97.8, 90.8, and 89.9%, respectively. Conclusion: DSCT coronary angiography has high diagnostic accuracy in assessing CAD among patients at intermediate to high risk without using heart rate-modulating premedication. DSCT is not superior to ICA for diagnosis of calcified segments.

  16. Validation of an algorithm-based definition of treatment resistance in patients with schizophrenia.

    Science.gov (United States)

    Ajnakina, Olesya; Horsdal, Henriette Thisted; Lally, John; MacCabe, James H; Murray, Robin M; Gasse, Christiane; Wimberley, Theresa

    2018-02-19

    Large-scale pharmacoepidemiological research on treatment resistance relies on accurate identification of people with treatment-resistant schizophrenia (TRS) based on data that are retrievable from administrative registers. This is usually approached by operationalising clinical treatment guidelines by using prescription and hospital admission information. We examined the accuracy of an algorithm-based definition of TRS based on clozapine prescription and/or meeting algorithm-based eligibility criteria for clozapine against a gold standard definition using case notes. We additionally validated a definition entirely based on clozapine prescription. 139 schizophrenia patients aged 18-65years were followed for a mean of 5years after first presentation to psychiatric services in South-London, UK. The diagnostic accuracy of the algorithm-based measure against the gold standard was measured with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). A total of 45 (32.4%) schizophrenia patients met the criteria for the gold standard definition of TRS; applying the algorithm-based definition to the same cohort led to 44 (31.7%) patients fulfilling criteria for TRS with sensitivity, specificity, PPV and NPV of 62.2%, 83.0%, 63.6% and 82.1%, respectively. The definition based on lifetime clozapine prescription had sensitivity, specificity, PPV and NPV of 40.0%, 94.7%, 78.3% and 76.7%, respectively. Although a perfect definition of TRS cannot be derived from available prescription and hospital registers, these results indicate that researchers can confidently use registries to identify individuals with TRS for research and clinical practices. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. MR evaluation of breast lesions obtained by diffusion-weighted imaging with background body signal suppression (DWIBS) and correlations with histological findings.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Capolongo, Arcangela; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-07-01

    Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions. 90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3)mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated. In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of >1.44 and 37 (70%) with ADC≤1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively. DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. SYNTHESIS AND CHARACTERIZATION OF NOVEL BIPOLAR PPV-BASED COPOLYMER CONTAINING TRIAZOLE AND CARBAZOLE UNITS

    Institute of Scientific and Technical Information of China (English)

    Ze Liu; Li-xiang Wang; Xia-bin Jing; Fo-song Wang

    2001-01-01

    Two new blue light-emitting PPV-based conjugated copolymers containing both an electron-withdrawing unit (triazole-TAZ) and electron-rich moieties (carbazole-CAR and bicarbazole-BCAR) were prepared by Wittig condensation polymerization between the triazole diphosphonium salt and the corresponding dialdehyde monomers. Their structures and properties were characterized by FT-IR, TGA, DSC, UV-Vis, PL spectroscopy and electrochemical measurements. The resulting copolymers are soluble in common organic solvents and thermally stable with a Ts of 147C for TAZ-CAR-PPV and of 157C for TAZ-BCAR-PPV. The maximum photoluminescence wavelengths of TAZ-CAR-PPV and TAZ-BCAR-PPV film appear at 460 nm and 480 nm, respectively. Cyclic voltammetry measurement demonstrates that TAZ-BCAR-PPV has good electrochemical reversibility, while TAZ-CAR-PPV exhibits the irreversible redox process. The triazole unit was found to be an effective π-conjugation interrupter and can play the rigid spacer role in determining the emission colour of the resulting copolymer.

  19. 56 . ORIGINAL ARTICLE

    African Journals Online (AJOL)

    User

    1 Department of Microbiology, College of Natural and Applied Sciences, ... The Clinotech TB Screen test, a 3rd generation multi-antigen rapid ... The positive and Negative Predictive Values (PPV and NPV) were 79.2% ... The study participants were recruited from TB ... from home the next day, and the second spot sample.

  20. Screening method for Staphylococcus aureus identification in subclinical bovine mastitis from dairy farms

    Directory of Open Access Journals (Sweden)

    Natapol Pumipuntu

    2017-07-01

    Full Text Available Background: Staphylococcus aureus is one of the most important contagious bacteria causing subclinical bovine mastitis. This bacterial infection is commonly identified by determine the pathogen in bovine milk samples through conventional technique including coagulase test. However, this test has several disadvantages as low sensitivity, risk of biohazard, cost expensive, and limited preparation especially in local area. Aim: Aim of this study was to compare and assess the screening method, Mannitol fermentation test (Mannitol salt agar [MSA], and deoxyribonuclease (DNase test, for S. aureus identification in milk samples. Materials and Methods: A total of 224 subclinical bovine mastitis milk samples were collected from four provinces of Thailand and determined S. aureus using conventional method and also subjected to the screening test, MSA and DNase test. The sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV among both tests were analyzed and compared to the tube coagulase test (TCT, as reference method. Immunological test by latex agglutination and molecular assay by determined spa gene were also used to identify and differentiate S. aureus. Results: A total of 130 staphylococci were isolated by selective media, Gram-stain, and catalase test. The number of S. aureus which identified using TCT, MSA and DNase test were 32, 102, and 74 isolates, respectively. All TCT results were correlated to results of latex agglutination and spa gene which were 32 S. aureus. MSA showed 100% sensitivity, 28.57% specificity, 31.37% PPV, and 100% NPV, whereas DNase showed 53.13% sensitivity, 41.84% specificity, 22.97% PPV, and 73.21% NPV. DNase test showed higher specificity value than MSA but the test presented 26.79% false negative results whereas no false-negative result from MSA when comparing to TCT. Conclusion: MSA had a tendency to be a good preference for screening S. aureus because of its high sensitivity and

  1. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients; Kann die kontrastmittelverstaerkte Mehrzeilen-Computertomografie die transoesophageale Echokardiografie bei der Detektion von thrombogenem Milieu und Vorhofohrthromben ersetzen? Eine prospektive Studie mit 124 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Nath, B. [SHG-KLliniken Voelklingen (Germany). Dept. of Medicine I - Cardiology; Schwab, J.O. [Bonn Univ. (Germany). Dept. of Medicine I - Cardiology

    2016-01-15

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  2. Termination of Resuscitation Rules to Predict Neurological Outcomes in Out-of-Hospital Cardiac Arrest for an Intermediate Life Support Prehospital System.

    Science.gov (United States)

    Cheong, Randy Wang Long; Li, Huihua; Doctor, Nausheen Edwin; Ng, Yih Yng; Goh, E Shaun; Leong, Benjamin Sieu-Hon; Gan, Han Nee; Foo, David; Tham, Lai Peng; Charles, Rabind; Ong, Marcus Eng Hock

    2016-01-01

    Futile resuscitation can lead to unnecessary transports for out-of-hospital cardiac arrest (OHCA). The Basic Life Support (BLS) and Advanced Life Support (ALS) termination of resuscitation (TOR) guidelines have been validated with good results in North America. This study aims to evaluate the performance of these two rules in predicting neurological outcomes of OHCA patients in Singapore, which has an intermediate life support Emergency Medical Services (EMS) system. A retrospective cohort study was carried out on Singapore OHCA data collected from April 2010 to May 2012 for the Pan-Asian Resuscitation Outcomes Study (PAROS). The outcomes of each rule were compared to the actual neurological outcomes of the patients. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and predicted transport rates of each test were evaluated. A total of 2,193 patients had cardiac arrest of presumed cardiac etiology. TOR was recommended for 1,411 patients with the BLS-TOR rule, with a specificity of 100% (91.9, 100.0) for predicting poor neurological outcomes, PPV 100% (99.7, 100.0), sensitivity 65.7% (63.6, 67.7), NPV 5.6% (4.1, 7.5), and transportation rate 35.6%. Using the ALS-TOR rule, TOR was recommended for 587 patients, specificity 100% (91.9, 100.0) for predicting poor neurological outcomes, PPV 100% (99.4, 100.0), sensitivity 27.3% (25.4, 29.3), NPV 2.7% (2.0, 3.7), and transportation rate 73.2%. BLS-TOR predicted survival (any neurological outcome) with specificity 93.4% (95% CI 85.3, 97.8) versus ALS-TOR 98.7% (95% CI 92.9, 99.8). Both the BLS and ALS-TOR rules had high specificities and PPV values in predicting neurological outcomes, the BLS-TOR rule had a lower predicted transport rate while the ALS-TOR rule was more accurate in predicting futility of resuscitation. Further research into unique local cultural issues would be useful to evaluate the feasibility of any system-wide implementation of TOR.

  3. Is the Atopy Patch Test Reliable in the Evaluation of Food Allergy-Related Atopic Dermatitis?

    Science.gov (United States)

    Mansouri, Mahboubeh; Rafiee, Elham; Darougar, Sepideh; Mesdaghi, Mehrnaz; Chavoshzadeh, Zahra

    2018-01-01

    Aeroallergens and food allergens are found to be relevant in atopic dermatitis. The atopy patch test (APT) can help to detect food allergies in children with atopic dermatitis. This study evaluates if the APT is a valuable tool in the diagnostic workup of children with food allergy-related atopic dermatitis. 42 children between 6 months and 12 years of age were selected at the Mofid Children Hospital. Atopic dermatitis was diagnosed, and the severity of the disease was determined. At the test visit, the patients underwent a skin prick test (SPT), APT, and serum IgE level measurement for cow's milk, egg yolk, egg white, wheat, and soy. We found a sensitivity of 91.7%, a specificity of 72.7%, a positive predictive value (PPV) of 88%, a negative predictive value (NPV) of 80%, and an accuracy of 85.7% for APT performed for cow's milk. APT performed for egg yolk had a sensitivity and a NPV of 100%, while the same parameters obtained with egg white were 84.2 and 75%, respectively. The sensitivity, specificity, and NPV of the APT for wheat were 100, 75, and 100%, respectively. The sensitivity, PPV, and NPV of the APT for soy were 87.5, 70, and 87.5%, respectively. Our data demonstrate that the APT is a reliable diagnostic tool to evaluate suspected food allergy-related skin symptoms in childhood and infancy. © 2018 S. Karger AG, Basel.

  4. Detection of antibodies against porcine parvovirus nonstructural protein NS1 may distinguish between vaccinated and infected pigs

    DEFF Research Database (Denmark)

    Madsen, Eva Smedegaard; Madsen, Knud Gert; Nielsen, Jens

    1997-01-01

    The humoral antibody response against the nonstructural protein NS1 and the structural protein VP2 of porcine parvovirus (PPV) was evaluated by immuno-peroxidase test (IPT) and enzyme linked immune sorbent assay (ELISA) using recombinant PPV antigens. The coding sequence for NS1 and VP2...... was inserted into the baculovirus Autographa californica nuclear polyhedrosis virus (AcNPV) genome resulting in two recombinant baculoviruses AcNPV-NS1 and AcNPV-VP2, respectively. Sf9 cells (Spodoptora frugidiperda) inoculated with AcNPV-NS1 producing recombinant nonstructural protein (rNS1) and AcNPV-VP2...... producing recombinant virion protein (rVP2) were used in IPT and ELISA to analyse serum antibodies. Pigs vaccinated with an inactivated whole virus vaccine and experimentally infected pigs were studied. Significant titers against rVP2 were obtained in both vaccinated and infected pigs. Specific antibodies...

  5. Added value of multiple versus single sessions of repetitive transcranial magnetic stimulation in predicting motor cortex stimulation efficacy for refractory neuropathic pain.

    Science.gov (United States)

    Pommier, Benjamin; Quesada, Charles; Fauchon, Camille; Nuti, Christophe; Vassal, François; Peyron, Roland

    2018-05-18

    OBJECTIVE Selection criteria for offering patients motor cortex stimulation (MCS) for refractory neuropathic pain are a critical topic of research. A single session of repetitive transcranial magnetic stimulation (rTMS) has been advocated for selecting MCS candidates, but it has a low negative predictive value. Here the authors investigated whether multiple rTMS sessions would more accurately predict MCS efficacy. METHODS Patients included in this longitudinal study could access MCS after at least four rTMS sessions performed 3-4 weeks apart. The positive (PPV) and negative (NPV) predictive values of the four rTMS sessions and the correlation between the analgesic effects of the two treatments were assessed. RESULTS Twelve MCS patients underwent an average of 15.9 rTMS sessions prior to surgery; nine of the patients were rTMS responders. Postoperative follow-up was 57.8 ± 15.6 months (mean ± standard deviation). Mean percentage of pain relief (%R) was 21% and 40% after the first and fourth rTMS sessions, respectively. The corresponding mean durations of pain relief were respectively 2.4 and 12.9 days. A cumulative effect of the rTMS sessions was observed on both %R and duration of pain relief (p < 0.01). The %R value obtained with MCS was 35% after 6 months and 43% at the last follow-up. Both the PPV and NPV of rTMS were 100% after the fourth rTMS session (p = 0.0045). A significant correlation was found between %R or duration of pain relief after the fourth rTMS session and %R at the last MCS follow-up (R 2 = 0.83, p = 0.0003). CONCLUSIONS Four rTMS sessions predicted MCS efficacy better than a single session in neuropathic pain patients. Taking into account the cumulative effects of rTMS, the authors found a high-level correlation between the analgesic effects of rTMS and MCS.

  6. Genome sequence of an enhancin gene-rich nucleopolyhedrovirus (NPV) from Agrotis segetum: collinearity with Spodoptera exigua multiple NPV

    NARCIS (Netherlands)

    Jakubowska, A.K.; Peters, S.A.; Ziemnicka, J.; Vlak, J.M.; Oers, van M.M.

    2006-01-01

    The genome sequence of a Polish isolate of Agrotis segetum nucleopolyhedrovirus (AgseNPV-A) was determined and analysed. The circular genome is composed of 147 544 bp and has a G+C content of 45¿7 mol%. It contains 153 putative, non-overlapping open reading frames (ORFs) encoding predicted proteins

  7. Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

    International Nuclear Information System (INIS)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Picone, Dario; Anastasi, Andrea; Midiri, Massimo; Lagalla, Roberto

    2017-01-01

    The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US). Thirty-seven consecutive cancer patients (24 women and 13 men; age, 33 to 80 years; mean, 58.1 years) with geographic liver fatty deposition, but without any detectable focal liver lesion on greyscale US, underwent sulphur hexafluoride-enhanced US. Two readers reported by consensus the presence, size, and location of any detected lesion. All patients underwent magnetic resonance imaging (MRI) as a confirmatory study. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and accuracy were calculated. Seven focal liver lesions (size, 4 to 10 mm; mean, 6.1 mm) were detected in 4/37 patients (10.8%): four metastases (size, 5 to 10 mm; mean, 6.7 mm) were detected both by CEUS and MRI, with one hemangioma and two cysts (size range, 4 to 6 mm; mean, 5.3 mm) detected by MRI only. In 1/37 patients (2.7%), CEUS misdiagnosed geographic fatty change as three metastases. In 32/37 patients (86.5%), no lesions were detected. Sensitivity, specificity, PPV, NPV, and accuracy of CEUS were 100% (95% confidence Interval [CI], 1.000 to 1.000), 97.1% (95% CI, 0.914 to 1.027), 75%, 100%, and 97.3%, respectively. No statistically significant differences were found between CEUS and MRI in the detection of focal liver lesions (P=0.480), whereas both of them performed better than baseline US (P<0.001). CEUS improves the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale US

  8. Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

    Energy Technology Data Exchange (ETDEWEB)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Picone, Dario; Anastasi, Andrea; Midiri, Massimo; Lagalla, Roberto [Dept. of Radiology-Di.Bi.Med., University of Palermo, Palermo (Italy)

    2017-04-15

    The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US). Thirty-seven consecutive cancer patients (24 women and 13 men; age, 33 to 80 years; mean, 58.1 years) with geographic liver fatty deposition, but without any detectable focal liver lesion on greyscale US, underwent sulphur hexafluoride-enhanced US. Two readers reported by consensus the presence, size, and location of any detected lesion. All patients underwent magnetic resonance imaging (MRI) as a confirmatory study. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and accuracy were calculated. Seven focal liver lesions (size, 4 to 10 mm; mean, 6.1 mm) were detected in 4/37 patients (10.8%): four metastases (size, 5 to 10 mm; mean, 6.7 mm) were detected both by CEUS and MRI, with one hemangioma and two cysts (size range, 4 to 6 mm; mean, 5.3 mm) detected by MRI only. In 1/37 patients (2.7%), CEUS misdiagnosed geographic fatty change as three metastases. In 32/37 patients (86.5%), no lesions were detected. Sensitivity, specificity, PPV, NPV, and accuracy of CEUS were 100% (95% confidence Interval [CI], 1.000 to 1.000), 97.1% (95% CI, 0.914 to 1.027), 75%, 100%, and 97.3%, respectively. No statistically significant differences were found between CEUS and MRI in the detection of focal liver lesions (P=0.480), whereas both of them performed better than baseline US (P<0.001). CEUS improves the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale US.

  9. Validation of Antibody-Based Strategies for Diagnosis of Pediatric Celiac Disease Without Biopsy.

    Science.gov (United States)

    Wolf, Johannes; Petroff, David; Richter, Thomas; Auth, Marcus K H; Uhlig, Holm H; Laass, Martin W; Lauenstein, Peter; Krahl, Andreas; Händel, Norman; de Laffolie, Jan; Hauer, Almuthe C; Kehler, Thomas; Flemming, Gunter; Schmidt, Frank; Rodrigues, Astor; Hasenclever, Dirk; Mothes, Thomas

    2017-08-01

    A diagnosis of celiac disease is made based on clinical, genetic, serologic, and duodenal morphology features. Recent pediatric guidelines, based largely on retrospective data, propose omitting biopsy analysis for patients with concentrations of IgA against tissue transglutaminase (IgA-TTG) >10-fold the upper limit of normal (ULN) and if further criteria are met. A retrospective study concluded that measurements of IgA-TTG and total IgA, or IgA-TTG and IgG against deamidated gliadin (IgG-DGL) could identify patients with and without celiac disease. Patients were assigned to categories of no celiac disease, celiac disease, or biopsy required, based entirely on antibody assays. We aimed to validate the positive and negative predictive values (PPV and NPV) of these diagnostic procedures. We performed a prospective study of 898 children undergoing duodenal biopsy analysis to confirm or rule out celiac disease at 13 centers in Europe. We compared findings from serologic analysis with findings from biopsy analyses, follow-up data, and diagnoses made by the pediatric gastroenterologists (celiac disease, no celiac disease, or no final diagnosis). Assays to measure IgA-TTG, IgG-DGL, and endomysium antibodies were performed by blinded researchers, and tissue sections were analyzed by local and blinded reference pathologists. We validated 2 procedures for diagnosis: total-IgA and IgA-TTG (the TTG-IgA procedure), as well as IgG-DGL with IgA-TTG (TTG-DGL procedure). Patients were assigned to categories of no celiac disease if all assays found antibody concentrations celiac disease if at least 1 assay measured antibody concentrations >10-fold the ULN. All other cases were considered to require biopsy analysis. ULN values were calculated using the cutoff levels suggested by the test kit manufacturers. HLA typing was performed for 449 participants. We used models that considered how specificity values change with prevalence to extrapolate the PPV and NPV to populations with lower

  10. Initial accuracy assessment of the modified S-LANSS for the detection of neuropathic orofacial pain conditions.

    Science.gov (United States)

    Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin

    2017-01-01

    To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.

  11. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  12. Diagnostic Accuracy of Dual-Source Computerized Tomography Coronary Angiography in Symptomatic Patients Presenting to a Referral Cardiovascular Center During Daily Clinical Practice

    International Nuclear Information System (INIS)

    Mahdavi, Arash; Mohammadzadeh, Ali; Joodi, Golsa; Tabatabaei, Mohammad Reza; Sheikholeslami, Farhad; Motevalli, Marzieh

    2016-01-01

    There are numerous studies that address the diagnostic value of dual-source computed tomography (DSCT) as an alternative to conventional coronary angiography (CCA). However, the benefit of application of DSCT in a real world clinical setting should be evaluated. To determine the diagnostic accuracy of DSCT technique compared with CCA as the gold standard method in detection of coronary artery stenosis among symptomatic patients who are presented to a referral cardiovascular center during daily clinical practice. Evaluating the medical records of a tertiary care referral cardiovascular center, 47 patients who had undergone DSCT and CCA, and also met the inclusion and exclusion criteria of the study were selected. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios (LRs) of the DSCT imaging technique were calculated. In total, 97.8% of the segments (628/642) could be visualized with diagnostic image quality via DSCT coronary angiography. The mean heart rate during DSCT was 69.2 ± 12.2 bpm (range: 39 - 83 bpm), and the mean Agatston score was 507.7 ± 590.5 (range: 0 - 2328). Per segment analysis of the findings revealed that the sensitivity, specificity, PPV, NPV, positive LR (PLR) and negative LR (NLR) of DSCT technique for evaluation of patients with coronary artery disease were 93.7%, 96.8%, 92.7%, 97.2%, 29.4, and 0.066, respectively. Also per vessel, analysis of the findings showed a sensitivity of 97.1%, a specificity of 94.0%, PPV of 95.3%, NPV of 96.3%, PLR of 16.1, and NLR of 0.030. Our results indicate that DSCT coronary angiography provides high diagnostic accuracy for the evaluation of CAD patients during daily routine practice of a referral cardiovascular setting

  13. Impact of enhancin genes on potency of LdNPV in gypsy moth

    Science.gov (United States)

    Kelli Hoover; Jim McNeil; Alyssa Gendron; James. Slavicek

    2011-01-01

    Lymantria dispar nucleopolyhedrovirus (LdNPV) contains two enhancin genes (E1 and E2) encoding proteases that degrade key peritrophic matrix (PM) proteins, thereby promoting infection and mortality by the virus. In a previous study, gypsy moth larvae inoculated with LdNPV in which both E1 and E2 were deleted (double deletion virus) resulted in a non-...

  14. Efficacy of PPV23 in Preventing Pneumococcal Pneumonia in Adults at Increased Risk--A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Julia Schiffner-Rohe

    Full Text Available Pneumococcal community-acquired pneumonia (pCAP is the most frequent form of pneumonia. The elderly and adults with underlying diseases are at an increased risk of developing pCAP. The 23-valent pneumococcal polysaccharide vaccine (PPV23 was licensed over 30 years ago and is recommended as the standard intervention in many countries across the globe, although its efficacy continues to be debated. We performed a meta-analysis of randomized controlled trials (RCTs to investigate the effect of PPV23 for preventing pCAP in adults ≥60 years of age.An existing Cochrane Review was updated to Oct 2014 using a systematic literature search to select appropriate RCTs. DerSimonian and Laird random-effects meta-analyses were performed and odd ratios (OR with 95%-confidence intervals (CI and p-values were calculated for the descriptive analyses. Reasons for heterogeneity were explored by subgroup analyses.Meta-analysis of PPV23 efficacy included four studies. Three of them did not demonstrate efficacy for PPV23. The body of evidence indicated statistically significant heterogeneity (I2 = 78%, p = 0.004 that could be explained by subgroup analysis by "study setting". Further effect modifiers for pCAP were "continent of trial" (p<0.01, and "method of pneumococcal diagnostics" (p = 0.001. Subgroup analyses revealed that the only study showing efficacy for PPV23 was an outlier. Overall, the validity of the meta-analytic PPV23 efficacy assessment was confirmed by the meta-analysis of all-cause CAP including six studies.Inconsistencies in PPV23 treatment effects to prevent pCAP could solely be explained by one outlier study that was performed in nursing homes in Japan. The effect modifier "method of pneumococcal diagnostics" should be interpreted carefully, since methodological weaknesses are not restricted to one special method only, which would justify the exclusion of certain studies. Overall, we conclude from our meta-analysis that to date there is no proof

  15. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  16. External Validity of Electronic Sniffers for Automated Recognition of Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    McKown, Andrew C; Brown, Ryan M; Ware, Lorraine B; Wanderer, Jonathan P

    2017-01-01

    Automated electronic sniffers may be useful for early detection of acute respiratory distress syndrome (ARDS) for institution of treatment or clinical trial screening. In a prospective cohort of 2929 critically ill patients, we retrospectively applied published sniffer algorithms for automated detection of acute lung injury to assess their utility in diagnosis of ARDS in the first 4 ICU days. Radiographic full-text reports were searched for "edema" OR ("bilateral" AND "infiltrate") and a more detailed algorithm for descriptions consistent with ARDS. Patients were flagged as possible ARDS if a radiograph met search criteria and had a PaO 2 /FiO 2 or SpO 2 /FiO 2 of 300 or 315, respectively. Test characteristics of the electronic sniffers and clinical suspicion of ARDS were compared to a gold standard of 2-physician adjudicated ARDS. Thirty percent of 2841 patients included in the analysis had gold standard diagnosis of ARDS. The simpler algorithm had sensitivity for ARDS of 78.9%, specificity of 52%, positive predictive value (PPV) of 41%, and negative predictive value (NPV) of 85.3% over the 4-day study period. The more detailed algorithm had sensitivity of 88.2%, specificity of 55.4%, PPV of 45.6%, and NPV of 91.7%. Both algorithms were more sensitive but less specific than clinician suspicion, which had sensitivity of 40.7%, specificity of 94.8%, PPV of 78.2%, and NPV of 77.7%. Published electronic sniffer algorithms for ARDS may be useful automated screening tools for ARDS and improve on clinical recognition, but they are limited to screening rather than diagnosis because their specificity is poor.

  17. Double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours.

    Science.gov (United States)

    Burke, Elinor; Grobler, Mariana; Elderfield, Kay; Bond, Frances; Crocker, Matthew; Taylor, Rohan; Bridges, Leslie R

    2013-06-10

    Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard.

  18. Diagnostic utility of a one-item question to screen for depressive disorders: results from the KORA F3 study.

    Science.gov (United States)

    Blozik, Eva; Scherer, Martin; Lacruz, Maria E; Ladwig, Karl-Heinz

    2013-12-23

    Screening for depressive disorders in the general adult population is recommended, however, it is unclear which instruments combine user friendliness and diagnostic utility. We evaluated the test performance of a yes/no single item screener for depressive disorders ("Have you felt depressed or sad much of the time in the past year?") in comparison to the depressive disorder module of the Patient Health Questionnaire (PHQ-9). Data from 3184 participants of the population-based KORA F3 survey in Augsburg/ Germany were used to analyse sensitivity, specificity, ROC area, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), and negative predictive value (NPV) of the single item screener in comparison with "depressive mood" and "major depressive disorder" defined according to PHQ-9 (both interviewer-administered versions). In comparison to PHQ-9 "depressive mood", sensitivity was low (46%) with an excellent specificity (94%), (PPV 76%; NPV 82%; LR + 8.04; LR- .572, ROC area .702). When using the more conservative definition for "major depressive disorder", sensitivity increased to 83% with a specificity of 88%. The PPV under the conservative definition was low (32%), but NPV was 99% (LR + 6.65; LR- .196; ROC area .852). Results varied across age groups and between males and females. The single item screener is able to moderately decrease post-test probability of major depressive disorders and to identify populations that should undergo additional, more detailed evaluation for depression. It may have limited utility in combination with additional screening tests or for selection of at-risk populations, but cannot be recommended for routine use as a screening tool in clinical practice.

  19. The influence of prostate-specific antigen density on positive and negative predictive values of multiparametric magnetic resonance imaging to detect Gleason score 7-10 prostate cancer in a repeat biopsy setting.

    Science.gov (United States)

    Hansen, Nienke L; Barrett, Tristan; Koo, Brendan; Doble, Andrew; Gnanapragasam, Vincent; Warren, Anne; Kastner, Christof; Bratt, Ola

    2017-05-01

    To evaluate the influence of prostate-specific antigen density (PSAD) on positive (PPV) and negative (NPV) predictive values of multiparametric magnetic resonance imaging (mpMRI) to detect Gleason score ≥7 cancer in a repeat biopsy setting. Retrospective study of 514 men with previous prostate biopsy showing no or Gleason score 6 cancer. All had mpMRI, graded 1-5 on a Likert scale for cancer suspicion, and subsequent targeted and 24-core systematic image-fusion guided transperineal biopsy in 2013-2015. The NPVs and PPVs of mpMRIs for detecting Gleason score ≥7 cancer were calculated (±95% confidence intervals) for PSAD ≤0.1, 0.1-0.2, ≤0.2 and >0.2 ng/mL/mL, and compared by chi-square test for linear trend. Gleason score ≥7 cancer was detected in 31% of the men. The NPV of Likert 1-2 mpMRI was 0.91 (±0.04) with a PSAD of ≤0.2 ng/mL/mL and 0.71 (±0.16) with a PSAD of >0.2 ng/mL/mL (P = 0.003). For Likert 3 mpMRI, PPV was 0.09 (±0.06) with a PSAD of ≤0.2 ng/mL/mL and 0.44 (±0.19) with a PSAD of >0.2 ng/mL/mL (P = 0.002). PSAD also significantly affected the PPV of Likert 4-5 mpMRI lesions: the PPV was 0.47 (±0.08) with a PSAD of ≤0.2 ng/mL/mL and 0.66 (±0.10) with a PSAD of >0.2 ng/mL/mL (P prostate cancer, not only in men with negative mpMRI, but also in men with equivocal imaging. Surveillance, rather than repeat biopsy, may be appropriate for these men. Conversely, biopsies are indicated in men with a high PSAD, even if an mpMRI shows no suspicious lesion, and in men with an mpMRI suspicious for cancer, even if the PSAD is low. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  20. The value of FDG-PET/CT in assessing single pulmonary nodules in patients at high risk of lung cancer

    International Nuclear Information System (INIS)

    Kagna, Olga; Solomonov, Anna; Fruchter, Oren; Keidar, Zohar; Bar-Shalom, Rachel; Israel, Ora; Yigla, Mordechai; Guralnik, Luda

    2009-01-01

    To evaluate whether PET/low-dose CT (ldCT) using 18 F-fluorodeoxyglucose (FDG) improves characterization of indeterminate single pulmonary nodules (SPNs) in patients at high risk of lung cancer. Retrospective analysis of 307 patients who underwent FDG-PET/CT for indeterminate SPNs identified 93 (70 men, age range 46-90 years) at high risk of lung cancer (age >40 years, minimum 10 pack-year smokers). SPNs were evaluated for the presence and intensity of FDG avidity and ldCT patterns. The performance of visual and semiquantitative FDG-PET/ldCT algorithms for characterization of SPNs was compared to that of ldCT. Incongruent FDG-PET and ldCT patterns were analyzed for significance in further patient management. Malignancy was diagnosed in 38% patients. FDG avidity defined 33 SPNs as true-positive (TP) and 2 as false-negative (FN) (malignant), and 41 as true-negative (TN) and 17 as false-positive (FP) (benign). For SUVmax of 2.2 (by ROC analysis) there were 27 TP, 8 FN, 48 TN and 10 FP SPNs. LdCT defined 34 TP, 1 FN, 28 TN and 30 FP lesions. Of the FP lesions on ldCT, 60% were FDG-negative. Visual PET/ldCT analysis had a sensitivity of 94%, a specificity of 70%, an accuracy of 80%, a positive predictive value (PPV) of 66%, and a negative predictive value (NPV) of 95% as compared to 77%, 83%, 81%, 73%, 86% for semiquantitative PET/ldCT and 97%, 48%, 66%, 53%, 96% for ldCT, respectively. Both PET/ldCT algorithms had statistically significantly higher specificity and accuracy than ldCT. Semiquantitative analysis showed significantly higher PPV and lower sensitivity and NPV than found with ldCT. A single screening procedure encompassing FDG-PET and ldCT may improve screening for lung cancer in high-risk patients. The significantly improved specificity may potentially reduce FP ldCT results and further unnecessary invasive procedures. (orig.)

  1. Predictive value of antinuclear antibodies in autoimmune diseases classified by clinical criteria: Analytical study in a specialized health institute, one year follow-up

    Directory of Open Access Journals (Sweden)

    María Elena Soto

    2015-01-01

    Full Text Available Introduction: Determination of antinuclear antibodies (ANA by indirect immunofluorescence (IIF is usually the initial test for the diagnosis of systemic rheumatic diseases (SRD. Assigning predictive values to positive and negative results of the test is vital because lack of knowledge about ANAs and their usefulness in classification criteria of SRD leads to inappropriate use. Methods: Retrospective study, ANA tests requested by different specialties, correlation to patients' final diagnosis. Results: The prevalence of autoimmune disease was relatively low in our population yielding a low PPV and a high NPV for the ANA test. 40% of the patients had no clinical criteria applied prior to test. Coexistence of two or more autoimmune disorders affects prevalence and predictive values. Conclusion: Application of the test after careful evaluation for clinical criteria remarkably improves the positive likelihood ratio for the diagnosis.

  2. Role of serum S100B and PET-CT in follow-up of patients with cutaneous melanoma

    Directory of Open Access Journals (Sweden)

    Novakovic Srdjan

    2011-08-01

    Full Text Available Abstract Background Increased level of serum S100B can serve as a marker of metastatic spread in patients with cutaneous melanoma (CM. In patients with elevated S100 B and/or clinical signs of disease progression PET-CT scan is a valuable tool for discovering metastases and planning treatment. The aims of this study were to determine whether regular measurements of serum S100B are a useful tool for discovering patients with CM metastases and to evaluate the diagnostic value of PET-CT during the follow-up. Methods From September 2007 to February 2010, 115 CM patients included in regular follow up at the Institute of Oncology Ljubljana were appointed to PET-CT. There were 82 (71.3% patients with clinical signs of disease progression and 33 (28.7% asymptomatic patients with two subsequent elevated values of S100B. Sensitivity, specificity, positive and negative predictive value (PPV, NPV of S100B and PET-CT were calculated using standard procedures. Results Disease progression was confirmed in 81.7% of patients (in 86.5% of patients with clinical signs of disease progression and in 69.7% of asymptomatic patients with elevated S100B. Sensitivity, specificity, PPV and NPV of S100B was 33.8%, 90.9%, 96.0% and 17.5% in patients with clinical signs of disease progression. In 20.0% of patients increased serum S100B was the only sign of disease progression. Sensitivity and PPV of S100 in this group of patients were 100.0% and 69.7%. With PET-CT disease progression was diagnosed in 84.2% of symptomatic patients and in 72.7% of asymptomatic patients with elevated S100B. The sensitivity, specificity, PPV and NPV of PET-CT for symptomatic patients was 98.5%, 90.9%, 98.5% and 90.9% and 100%, 90.0%, 95.8% and 100% for asymptomatic patients with elevated S100. Conclusions Measurements of serum S100B during regular follow-up of patients with CM are a useful tool for discovering disease progression in asymptomatic patients. The value of its use increases if

  3. Expression analysis of several antiviral related genes to BmNPV in different resistant strains of silkworm, Bombyx mori.

    Science.gov (United States)

    Cheng, Yang; Wang, Xue-yang; Du, Chang; Gao, Juan; Xu, Jia-ping

    2014-05-30

    Bombyx mori L. (Lepidoptera: Bombycidae) nucleopolyhedrovirus (BmNPV) is a highly pathogenic virus in the sericultural industry, often causing severe damage leading to large economic losses. The immune mechanisms of B. mori against this virus remain obscure. Previous studies had demonstrated Bmlipase-1, BmNox and Bmserine protease-2 showing antiviral activity in vitro, but data on the transcription levels of these proteins in different resistant strains were not reported. In order to determine the resistance level of the four different strains (P50, A35, A40, A53) and gain a better understanding of the mechanism of resistance to BmNPV in B. mori, the relative expression level of the genes coding the three antiviral proteins in larval haemolymph and midgut of different B. mori strains resistant to BmNPV was determined. The results showed that these genes expressed significantly higher in the resistant strains compared to the susceptible strain, and the differential expression levels were consistent with the LC50 values in different strains. The transcription level of the target genes almost all up-regulated in the larvae midgut and down-regulated in the haemolymph. The results indicate the correlation of these genes to BmNPV resistance in B. mori. This is an open access paper. We use the Creative Commons Attribution 3.0 license that permits unrestricted use, provided that the paper is properly attributed.

  4. Role of PCR method using IS6110 primer in detecting Mycobacterium tuberculosis among the clinically diagnosed childhood tuberculosis patients at an urban hospital in Dhaka, Bangladesh.

    Science.gov (United States)

    Kabir, Senjuti; Uddin, Mohammad Khaja Mafij; Chisti, Mohammod Jobayer; Fannana, Tilka; Haque, Mohammad Enamul; Uddin, Muhammad Reaj; Banu, Sayera; Ahmed, Tahmeed

    2018-03-01

    Better methods are needed for the accurate detection of child tuberculosis (TB). This study compared different laboratory tests and evaluated IS6110 PCR for the detection of Mycobacterium tuberculosis (MTB) among clinically diagnosed child TB patients. A total of 102 paediatric patients (PCR testing. The sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of smear microscopy and PCR were compared to the two culture methods. Three patients were positive on smear microscopy (2.9%). MTB was detected by conventional culture in 15.7% (16/102), liquid culture in 14% (14/100), and IS6110 PCR in 61.8% (63/102). PCR detected an additional 45 patients who were undetected with the three other tests. Compared to conventional and liquid culture, respectively, smear microscopy showed sensitivity of 18.8% and 21.4%, specificity of 100% individually, PPV of 100% individually, and NPV of 86.9% and 88.7%, whereas PCR had sensitivity of 87.5% and 92.9%, specificity of 43% individually, PPV of 22.2% and 21%, and NPV of 94.9% and 97.4%. PCR can be useful compared to smear microscopy and culture methods and is applicable as a rapid screening test for child TB. A larger scale study is required to determine its diagnostic efficacy in improving the detection of child TB in the presence and absence of severe malnutrition. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer

    International Nuclear Information System (INIS)

    Lefere, Philippe; Silva, Celso; Gryspeerdt, Stefaan; Rodrigues, António; Vasconcelos, Rita; Teixeira, Ricardo; Gouveia, Francisco Henriques de

    2013-01-01

    Purpose: To prospectively assess the performance of teleradiology-based CT colonography to screen a population group of an island, at average risk for colorectal cancer. Materials and methods: A cohort of 514 patients living in Madeira, Portugal, was enrolled in the study. Institutional review board approval was obtained and all patients signed an informed consent. All patients underwent both CT colonography and optical colonoscopy. CT colonography was interpreted by an experienced radiologist at a remote centre using tele-radiology. Per-patient sensitivity, specificity, positive (PPV) and negative (NPV) predictive values with 95% confidence intervals (95%CI) were calculated for colorectal adenomas and advanced neoplasia ≥6 mm. Results: 510 patients were included in the study. CT colonography obtained a per-patient sensitivity, specificity, PPV and, NPV for adenomas ≥6 mm of 98.11% (88.6–99.9% 95% CI), 90.97% (87.8–93.4% 95% CI), 56.52% (45.8–66.7% 95% CI), 99.75% (98.4–99.9% 95% CI). For advanced neoplasia ≥6 mm per-patient sensitivity, specificity, PPV and, NPV were 100% (86.7–100% 95% CI), 87.07% (83.6–89.9% 95% CI), 34.78% (25.3–45.5% 95% CI) and 100% (98.8–100% 95% CI), respectively. Conclusion: In this prospective trial, teleradiology-based CT colonography was accurate to screen a patient cohort of a remote island, at average risk for colorectal cancer

  6. Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lefere, Philippe, E-mail: radiologie@skynet.be [VCTC, Virtual Colonoscopy Teaching Centre, Akkerstraat 32c, B-8830 Hooglede (Belgium); Silva, Celso, E-mail: caras@uma.pt [Human Anatomy of Medical Course, University of Madeira, Praça do Município, 9000-082 Funchal (Portugal); Gryspeerdt, Stefaan, E-mail: stefaan@sgryspeerdt.be [VCTC, Virtual Colonoscopy Teaching Centre, Akkerstraat 32c, B-8830 Hooglede (Belgium); Rodrigues, António, E-mail: nucleo@nid.pt [Nucleo Imagem Diagnostica, Rua 5 De Outubro, 9000-216 Funchal (Portugal); Vasconcelos, Rita, E-mail: rita@uma.pt [Department of Engineering and Mathematics, University of Madeira, Praça do Município, 9000-082 Funchal (Portugal); Teixeira, Ricardo, E-mail: j.teixeira1947@gmail.com [Department of Gastroenterology, Central Hospital of Funchal, Avenida Luís de Camões, 9004513 Funchal (Portugal); Gouveia, Francisco Henriques de, E-mail: fhgouveia@netmadeira.com [LANA, Pathology Centre, Rua João Gago, 10, 9000-071 Funchal (Portugal)

    2013-06-15

    Purpose: To prospectively assess the performance of teleradiology-based CT colonography to screen a population group of an island, at average risk for colorectal cancer. Materials and methods: A cohort of 514 patients living in Madeira, Portugal, was enrolled in the study. Institutional review board approval was obtained and all patients signed an informed consent. All patients underwent both CT colonography and optical colonoscopy. CT colonography was interpreted by an experienced radiologist at a remote centre using tele-radiology. Per-patient sensitivity, specificity, positive (PPV) and negative (NPV) predictive values with 95% confidence intervals (95%CI) were calculated for colorectal adenomas and advanced neoplasia ≥6 mm. Results: 510 patients were included in the study. CT colonography obtained a per-patient sensitivity, specificity, PPV and, NPV for adenomas ≥6 mm of 98.11% (88.6–99.9% 95% CI), 90.97% (87.8–93.4% 95% CI), 56.52% (45.8–66.7% 95% CI), 99.75% (98.4–99.9% 95% CI). For advanced neoplasia ≥6 mm per-patient sensitivity, specificity, PPV and, NPV were 100% (86.7–100% 95% CI), 87.07% (83.6–89.9% 95% CI), 34.78% (25.3–45.5% 95% CI) and 100% (98.8–100% 95% CI), respectively. Conclusion: In this prospective trial, teleradiology-based CT colonography was accurate to screen a patient cohort of a remote island, at average risk for colorectal cancer.

  7. T1 bright appendix sign to exclude acute appendicitis in pregnant women

    International Nuclear Information System (INIS)

    Shin, Ilah; An, Chansik; Lim, Joon Seok; Kim, Myeong-Jin; Chung, Yong Eun

    2017-01-01

    To evaluate the diagnostic value of the T1 bright appendix sign for the diagnosis of acute appendicitis in pregnant women. This retrospective study included 125 pregnant women with suspected appendicitis who underwent magnetic resonance (MR) imaging. The T1 bright appendix sign was defined as a high intensity signal filling more than half length of the appendix on T1-weighted imaging. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the T1 bright appendix sign for normal appendix identification were calculated in all patients and in those with borderline-sized appendices (6-7 mm). The T1 bright appendix sign was seen in 51% of patients with normal appendices, but only in 4.5% of patients with acute appendicitis. The overall sensitivity, specificity, PPV, and NPV of the T1 bright appendix sign for normal appendix diagnosis were 44.9%, 95.5%, 97.6%, and 30.0%, respectively. All four patients with borderline sized appendix with appendicitis showed negative T1 bright appendix sign. The T1 bright appendix sign is a specific finding for the diagnosis of a normal appendix in pregnant women with suspected acute appendicitis. (orig.)

  8. T1 bright appendix sign to exclude acute appendicitis in pregnant women

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ilah; An, Chansik; Lim, Joon Seok; Kim, Myeong-Jin; Chung, Yong Eun [Yonsei University College of Medicine, Department of Radiology, Research Institute of Radiological Science, Severance Hospital, 50-1 Yonsei-ro, Seodaemun-gu, Seoul (Korea, Republic of)

    2017-08-15

    To evaluate the diagnostic value of the T1 bright appendix sign for the diagnosis of acute appendicitis in pregnant women. This retrospective study included 125 pregnant women with suspected appendicitis who underwent magnetic resonance (MR) imaging. The T1 bright appendix sign was defined as a high intensity signal filling more than half length of the appendix on T1-weighted imaging. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the T1 bright appendix sign for normal appendix identification were calculated in all patients and in those with borderline-sized appendices (6-7 mm). The T1 bright appendix sign was seen in 51% of patients with normal appendices, but only in 4.5% of patients with acute appendicitis. The overall sensitivity, specificity, PPV, and NPV of the T1 bright appendix sign for normal appendix diagnosis were 44.9%, 95.5%, 97.6%, and 30.0%, respectively. All four patients with borderline sized appendix with appendicitis showed negative T1 bright appendix sign. The T1 bright appendix sign is a specific finding for the diagnosis of a normal appendix in pregnant women with suspected acute appendicitis. (orig.)

  9. 20 g PPV with indocyanine green-assisted ILM peeling versus 23 g PPV with brilliant blue G-assisted ILM peeling for epiretinal membrane.

    Science.gov (United States)

    Manousaridis, Kleanthis; Peter, Silvia; Mennel, Stefan

    2016-06-01

    To compare the anatomical and visual outcomes of 20 gauge (g) pars plana vitrectomy (PPV) with indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling and 23 g PPV with brilliant blue G (BBG)-assisted ILM peeling for idiopathic epiretinal membrane (ERM). 38 eyes of 38 patients with idiopathic ERM were included. They were divided in two groups: group 1 (18 eyes) underwent 20 g PPV with ICG-assisted ILM peeling and group 2 (20 eyes) 23 g PPV with BBG-assisted ILM peeling. Postoperative best-corrected visual acuity (BCVA) and central macular thickness (CMT) were compared. Average BCVA in group 1 improved significantly from 0.60 logarithm of the minimal angle of resolution (log MAR) at baseline to 0.3 log MAR postoperatively. Average BCVA in group 2 improved significantly from 0.60 log MAR at baseline to 0.3 log MAR postoperatively. Mean CMT reduced significantly from 473 to 375 μm in group 1 and from 486 to 396 μm in group 2. There were no significant differences in the BCVA and CMT between the groups. Both surgical methods appeared to be safe and provided similar anatomical and visual outcomes.

  10. Muscle Weakness in the Empty and Full Can Tests Cannot Differentiate Rotator Cuff Tear from Cervical Spondylotic Amyotrophy: Pain Provocation is a Useful Finding.

    Science.gov (United States)

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Sakamoto, Yoshihiro; Tanaka, Yasuhito

    2017-01-01

    Rotator cuff tears and cervical spondylotic amyotrophy (CSA) are often confused as the main symptom in those with difficulty in shoulder elevation. Empty and full can tests are frequently used for the clinical diagnosis of rotator cuff tears. The aim of the present study was to investigate whether the empty and full can test results can help differentiate rotator cuff tears from CSA. Twenty-seven consecutive patients with rotator cuff tears and 25 with CSA were enrolled. We prospectively performed empty and full can tests in patients with rotator cuff tears and CSA. The following signs were considered positive: (a) muscle weakness during the empty can test, (b) muscle weakness during the full can test, (c) pain provocation during the empty can test, and (d) pain provocation during the full can test. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of rotator cuff tears for each positive finding. The sensitivity and specificity of each index were as follows (sensitivity, specificity, PPV, NPV): (a) 77.8%, 0%, 45.7%, 0%; (b) 66.7%, 4.0%, 42.9%, 10.0%; (c) 88.9%, 96.0%, 96.0%, 88.9%; and (d) 74.1%, 96.0%, 95.2%, 77.4%. There were significant differences for each index. Muscle weakness during the empty and full can tests was not useful in differentiating rotator cuff tears from CSA because of low specificity and PPV. However, pain provocation was useful in differentiating these two conditions because of high specificity and PPV.

  11. Assessment of patency capsule retention using MR diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne [Sheba Medical Center, Department of Diagnostic Imaging, Ramat Gan (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami [Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Sheba Medical Center, Department of Gastroenterology, Ramat Gan (Israel)

    2017-12-15

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm{sup 2}/s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  12. Benign versus malignant solid nodules in subareolar area of the breast: Radiological, clinical and pathological correlation

    International Nuclear Information System (INIS)

    Je, Bo Kyung; Seo, Bo Kyoung; Lee, Nam Joon; Jeon, Hae Jeong; Park, Jeong Hee; Cho, Kyu Ran; Lee, Ji Young; Choi, Eun Jeong; Lee, June Young; Kim, In Sun; Kim, Seok Jin

    2003-01-01

    To investigate the general applicability of ultrasonography (US) and clinical findings in differentiating benign from malignant solid nodules in the subareolar area of the breast. From March 2001 to March 2003, pathologically proven 84 nodules from 78 patients were included in this study. Two radiologists evaluated the shape, margins, internal echotexture, internal echogenicity, posterior echo intensity and relation with the major ducts, and each nodule was then classified as benign or malignant. Clinical findings were divided into either or absence of symptom. The ultrasonographic, mammographic and clinical classifications were compared with the pathological results. The sensitivity (SE), specificity (SP), positive predictive values (PPV) and negative predictive values (NPV) were calculated for ultrasonographic, mammographic and clinical classifications. Sixteen nodules were proved to be malignant (7 ductal carcinoma in situ and 9 invasive ductal carcinoma), and the remaining 68 nodules were benign. SE, SP, PPV, and NPV of breast cancer according to the ultrasonographical classification were 100%, 61.8%, 38.1% and 100% while those of the clinical classification were 81.3%, 73.5%, 41.9% and 94.3%, respectively. Relation with the major ducts such as ductal communication or intraductal location demonstrated a high SE (87.5%) and NPV (92.0%). Ultrasonographic and clinical findings can be helpful in the differentiation of benign solid nodules from malignant lesions in the subareolar area of the breast.

  13. Assessment of patency capsule retention using MR diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne; Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami

    2017-01-01

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm 2 /s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  14. Hybrid device based on GaN nanoneedles and MEH-PPV/PEDOT:PSS polymer

    International Nuclear Information System (INIS)

    Shin, Min Jeong; Gwon, Dong-Oh; Lee, Chan-Mi; Lee, Gang Seok; Jeon, In-Jun; Ahn, Hyung Soo; Yi, Sam Nyung; Ha, Dong Han

    2015-01-01

    Highlights: • A hybrid device was demonstrated by using MEH-PPV, PEDOT:PSS, and GaN nanoneedles. • I–V curve of the hybrid device showed its rectification behaviour, similar to a diode. • EL peak originated by the different potential barriers at MEH-PPV and GaN interface. - Abstract: A hybrid device that combines the properties of organic and inorganic semiconductors was fabricated and studied. It incorporated poly[2-methoxy-5-(2-ethylhexyloxy)- 1,4-phenylenevinylene] (MEH-PPV) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as organic polymers and GaN nanoneedles as an inorganic semiconductor. Layers of the two polymers were spin coated on to the GaN nanoneedles. The one peak in the electroluminescence spectrum originated from the MEH-PPV layer owing to the different potential barriers of electrons and holes at its interface with the GaN nanoneedles. However, the photoluminescence spectrum showed peaks due to both GaN nanoneedles and MEH-PPV. Such hybrid structures, suitably developed, might be able to improve the efficiency of optoelectronic devices

  15. Hybrid device based on GaN nanoneedles and MEH-PPV/PEDOT:PSS polymer

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Min Jeong; Gwon, Dong-Oh; Lee, Chan-Mi; Lee, Gang Seok [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Jeon, In-Jun [Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Ahn, Hyung Soo [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Yi, Sam Nyung, E-mail: snyi@kmou.ac.kr [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Ha, Dong Han [Division of Convergence Technology, Korea Research Institute of Standards and Science, Daejeon 305-340 (Korea, Republic of)

    2015-08-15

    Highlights: • A hybrid device was demonstrated by using MEH-PPV, PEDOT:PSS, and GaN nanoneedles. • I–V curve of the hybrid device showed its rectification behaviour, similar to a diode. • EL peak originated by the different potential barriers at MEH-PPV and GaN interface. - Abstract: A hybrid device that combines the properties of organic and inorganic semiconductors was fabricated and studied. It incorporated poly[2-methoxy-5-(2-ethylhexyloxy)- 1,4-phenylenevinylene] (MEH-PPV) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as organic polymers and GaN nanoneedles as an inorganic semiconductor. Layers of the two polymers were spin coated on to the GaN nanoneedles. The one peak in the electroluminescence spectrum originated from the MEH-PPV layer owing to the different potential barriers of electrons and holes at its interface with the GaN nanoneedles. However, the photoluminescence spectrum showed peaks due to both GaN nanoneedles and MEH-PPV. Such hybrid structures, suitably developed, might be able to improve the efficiency of optoelectronic devices.

  16. Diagnostic accuracy of the Rivalta test for feline infectious peritonitis.

    Science.gov (United States)

    Fischer, Yvonne; Sauter-Louis, Carola; Hartmann, Katrin

    2012-12-01

    The Rivalta test has been used routinely in Europe to diagnose feline infectious peritonitis (FIP) in cats with effusions, but its diagnostic accuracy is uncertain. The objectives of this study were to calculate sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values of the Rivalta test for FIP and to identify correlations between a positive Rivalta test and variables measured in effusion fluid and peripheral blood. In this retrospective study, medical records of cats with effusions were reviewed, and cats with conclusive results for the Rivalta test were included. The prevalence of FIP in this population was determined, and sensitivity, specificity, and PPV and NPV of the Rivalta test were calculated. Variables measured in effusion fluid and peripheral blood were compared between cats that had positive or negative Rivalta tests using the Mann-Whitney U-test and multivariate analysis. Of 851 cats with effusions, 782 had conclusively positive or negative results for the Rivalta test. A definitive final diagnosis was made in 497 of these cats. Prevalence of FIP in cats with effusion and a conclusive Rivalta test result was 34.6%. The Rivalta test had a sensitivity of 91.3%, specificity of 65.5%, PPV of 58.4%, and NPV of 93.4% for the diagnosis of FIP. These values increased when cats with lymphoma or bacterial infections were excluded, or when only cats ≤ 2 years were considered. Increased effusion cholesterol concentration and specific gravity as well as decreased serum albumin:globulin ratio and hyperbilirubinemia were positively correlated with positive Rivalta test results. Sensitivity, specificity, and PPV of the Rivalta test for the diagnosis of FIP were lower than previously reported except when used in young cats. The components in effusions that lead to a positive Rivalta test remain unknown, but the positivity is not simply related to high total protein concentration. © 2012 American Society for Veterinary Clinical Pathology.

  17. Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.

    Science.gov (United States)

    Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia

    2009-01-01

    Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.

  18. Professional values in Korean undergraduate nursing students.

    Science.gov (United States)

    Bang, Kyung Sook; Kang, Jeong Hee; Jun, Myung Hee; Kim, Hyun Sook; Son, Haeng Mi; Yu, Su Jeong; Kwon, Mi Kyung; Kim, Ji Soo

    2011-01-01

    Developing professional values among undergraduate nursing students is important since such values are a significant predictor of quality care, clients' recognition, and therefore nurses' job satisfaction. This study explored South Korean nursing students' perception of nursing professional values (NPV) and compared the NPV scores between groups according to participants' demographic characteristics. The study participants comprised of 529 students, mostly female (96.4%), with a mean age of 22.29years, sampled from six universities throughout the country. The NPV scores, measured with the 29-item Likert scale developed by Yeun et al. (2005), were significantly higher in students who entered nursing schools following their aptitude or desire for professional job than in those who entered the schools just because their entrance exam scores were sufficient. The NPV scores were also higher in students who were planning to pursue graduate study than in those who had not yet decided. The NPV scores were significantly different between the six regions, suggesting needs of in-depth studies to understand the underlying reasons. The NPV scores were not correlated, at the .05 level of significance, with academic year, gender, or academic performance. 2010 Elsevier Ltd. All rights reserved.

  19. The economic value of an investment in physiotherapy education: a net present value analysis.

    Science.gov (United States)

    Rivers, George; Foo, Jonathan; Ilic, Dragan; Nicklen, Peter; Reeves, Scott; Walsh, Kieran; Maloney, Stephen

    2015-07-01

    What is the economic value for an individual to invest in physiotherapy undergraduate education in Australia? How is this affected by increased education costs or decreased wages? A cost-benefit analysis using a net present value (NPV) approach was conducted and reported in Australian dollars. In relation to physiotherapy education, the NPV represents future earnings as a physiotherapist minus the direct and indirect costs in obtaining the degree. Sensitivity analyses were conducted to consider varying levels of experience, public versus private sector, and domestic versus international student fees. Comparable calculations were made for educational investments in medicine and nursing/midwifery. Assuming an expected discount rate of 9.675%, investment in education by domestic students with approximately 34 years of average work experience yields a NPV estimated at $784,000 for public sector physiotherapists and $815,000 for private sector therapists. In relation to international students, the NPV results for an investment and career as a physiotherapist is estimated at $705,000 in the public sector and $736,000 in the private sector. With an approximate payback period of 4 years, coupled with strong and positive NPV values, physiotherapy education in Australia is a financially attractive prospect and a viable value proposition for those considering a career in this field. Copyright © 2015 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  20. Correlation between conventional MR imaging combined with diffusion-weighted imaging and histopathologic findings in eyes primarily enucleated for advanced retinoblastoma. A retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Yanfen [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Xinhua Hospital, Shanghai (China); Shanxi Medical University, Department of Radiology, Shanxi Province Cancer Hospital, Taiyuan (China); Luo, Ran; Liu, Huanhuan; Zhang, Caiyuan; Zhang, Zhongyang; Wang, Dengbin [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Xinhua Hospital, Shanghai (China); Wang, Ruifen [Shanghai Jiao Tong University School of Medicine, Department of Pathology, Xinhua Hospital, Shanghai (China)

    2018-02-15

    To determine the diagnostic accuracy of conventional MRI in detecting tumour invasion of advanced intraocular retinoblastoma and to correlate ADC values with high-risk prognostic parameters. The sensitivities, specificities, positive predictive values (PPV), negative predictive values (NPV) and accuracies of MRI in detecting tumour-extent parameters of 63 retinoblastomas were determined. Furthermore, ADC values were correlated with high-risk prognostic parameters. MRI detected postlaminar optic nerve with a sensitivity of 73.3% (95% CI 44.9-92.2%) and a specificity of 89.6% (77.3-96.5%), while the specificity for choroidal invasion was only 31.8% (13.9-54.9%). Likewise, MRI failed to predicted early optic nerve invasion in terms of low sensitivity and PPV. In contrast, scleral and ciliary body invasion could be correctly excluded with high NPV. ADC values were significantly lower in patients with undifferentiated tumours, large tumour size, as with optic nerve and scleral invasion (all p < 0.05). However, no correlation was found between ADC values and the degree of choroidal or ciliary body infiltration. Additionally, ADC values were negatively correlated with Ki-67 index (r = -0.62, P = 0.002). Conventional MRI has some limitations in reliably predicting microscopic infiltration, with the diagnostic efficiency showing room for improvement, whereas ADC values correlated well with certain high-risk prognostic parameters for retinoblastoma. (orig.)

  1. MRI characteristics of torn and untorn post-operative menisci

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Rosas, Humberto; Liu, Fang [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Williams, Adam [Radiology and Imaging Consultants, Colorado Springs (United States)

    2017-10-15

    To compare magnetic resonance imaging (MRI) characteristics of torn and untorn post-operative menisci. The study group consisted of 140 patients with 148 partially resected menisci who were evaluated with a repeat knee MRI examination and subsequent repeat arthroscopic knee surgery. Two musculoskeletal radiologists retrospectively assessed the following MRI characteristics of the post-operative meniscus: contour (smooth or irregular), T2 line through the meniscus (no line, intermediate signal line, intermediate-to-high signal line, and high fluid-like signal line), displaced meniscus fragment, and change in signal pattern through the meniscus compared with baseline MRI. Positive predictive values (PPV) and negative predictive values (NPV) were calculated using arthroscopy as the reference standard. All 36 post-operative menisci with no T2 line were untorn at surgery (100% NPV), whereas 46 of the 79 post-operative menisci with intermediate T2 line, 16 of the 18 post-operative menisci with intermediate-to-high T2 line, and 14 of the 15 post-operative menisci with high T2 line were torn at surgery (58.2%, 88.9%, and 93.3% PPV respectively). Additional MRI characteristics associated with torn post-operative meniscus at surgery were irregular meniscus contour (PPV 85.7%), displaced meniscus fragment (PPV 100%), and change in signal pattern through the meniscus (PPV 99.4%). Post-operative menisci with no T2 signal line were untorn at surgery. The most useful MRI characteristics for predicting torn post-operative menisci at surgery were change in signal pattern through the meniscus compared with baseline MRI, and displaced meniscus fragment followed by high T2 line through the meniscus, intermediate-to-high T2 line through the meniscus, and irregular meniscus contour. (orig.)

  2. MRI characteristics of torn and untorn post-operative menisci

    International Nuclear Information System (INIS)

    Kijowski, Richard; Rosas, Humberto; Liu, Fang; Williams, Adam

    2017-01-01

    To compare magnetic resonance imaging (MRI) characteristics of torn and untorn post-operative menisci. The study group consisted of 140 patients with 148 partially resected menisci who were evaluated with a repeat knee MRI examination and subsequent repeat arthroscopic knee surgery. Two musculoskeletal radiologists retrospectively assessed the following MRI characteristics of the post-operative meniscus: contour (smooth or irregular), T2 line through the meniscus (no line, intermediate signal line, intermediate-to-high signal line, and high fluid-like signal line), displaced meniscus fragment, and change in signal pattern through the meniscus compared with baseline MRI. Positive predictive values (PPV) and negative predictive values (NPV) were calculated using arthroscopy as the reference standard. All 36 post-operative menisci with no T2 line were untorn at surgery (100% NPV), whereas 46 of the 79 post-operative menisci with intermediate T2 line, 16 of the 18 post-operative menisci with intermediate-to-high T2 line, and 14 of the 15 post-operative menisci with high T2 line were torn at surgery (58.2%, 88.9%, and 93.3% PPV respectively). Additional MRI characteristics associated with torn post-operative meniscus at surgery were irregular meniscus contour (PPV 85.7%), displaced meniscus fragment (PPV 100%), and change in signal pattern through the meniscus (PPV 99.4%). Post-operative menisci with no T2 signal line were untorn at surgery. The most useful MRI characteristics for predicting torn post-operative menisci at surgery were change in signal pattern through the meniscus compared with baseline MRI, and displaced meniscus fragment followed by high T2 line through the meniscus, intermediate-to-high T2 line through the meniscus, and irregular meniscus contour. (orig.)

  3. Comparison of the Quantitative Values of C-14 and C-13 UBT to Reflect the Presence and Degree of Ongoing Helicobacter pylori Infection

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee

    2008-01-01

    A urea breath test (UBT) using C-14 or C-13 has been developed for identifying Helicobacter (H) pylori infection on the basis of urease production with release of labeled CO 2 . We investigated if the C-14 and C-13 UBT have the difference to reflect the presence and degree of H. pylori infection detected by gastroduodenoscopic biopsies (GBx) in the same patients. Thirty eight patients (M:F=28:10, age 53.4±13.0 yrs) with upper gastrointestinal symptoms such as indigestion, gastric fullness or pain consecutively underwent C-14 UBT, GBx and C-13 UBT within one week before medications. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (37 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (≥200 dpm), intermediate (50∼199 dpm) or negative (<50 dpm). For the C-13 UBT, the results were classified as positive (≥2.5) or negative (<2.5). The results of GBx with Giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT and C-13 UBT results with GBx grade as a gold standard. The prevalence of H. pylori infection by GBx with Giemsa stain was 25/38 (65.8%). In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.0%, 92.3%, 95.8%, 91.7% and 92.1%, respectively. However, the C-13 UBT had sensitivity, specificity, PPV, NPV and accuracy of 96.0%, 84.6%, 92.3%, 91.7% and 92.1%, respectively. The more significant correlation in C-14 than C-13 UBT (r=0.948 vs r=0.819, p<0.001) was found between the value of UBT and the grade of distribution of H. pylori infection. We conclude that the diagnostic performance between C-14 and C-13 UBT to detect H. pylori infection is not significantly different, but the value of C-14 UBT more

  4. Comparison of the Quantitative Values of C-14 and C-13 UBT to Reflect the Presence and Degree of Ongoing Helicobacter pylori Infection

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Seok Tae; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2008-06-15

    A urea breath test (UBT) using C-14 or C-13 has been developed for identifying Helicobacter (H) pylori infection on the basis of urease production with release of labeled CO{sub 2}. We investigated if the C-14 and C-13 UBT have the difference to reflect the presence and degree of H. pylori infection detected by gastroduodenoscopic biopsies (GBx) in the same patients. Thirty eight patients (M:F=28:10, age 53.4{+-}13.0 yrs) with upper gastrointestinal symptoms such as indigestion, gastric fullness or pain consecutively underwent C-14 UBT, GBx and C-13 UBT within one week before medications. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (37 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive ({>=}200 dpm), intermediate (50{approx}199 dpm) or negative (<50 dpm). For the C-13 UBT, the results were classified as positive ({>=}2.5) or negative (<2.5). The results of GBx with Giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT and C-13 UBT results with GBx grade as a gold standard. The prevalence of H. pylori infection by GBx with Giemsa stain was 25/38 (65.8%). In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.0%, 92.3%, 95.8%, 91.7% and 92.1%, respectively. However, the C-13 UBT had sensitivity, specificity, PPV, NPV and accuracy of 96.0%, 84.6%, 92.3%, 91.7% and 92.1%, respectively. The more significant correlation in C-14 than C-13 UBT (r=0.948 vs r=0.819, p<0.001) was found between the value of UBT and the grade of distribution of H. pylori infection. We conclude that the diagnostic performance between C-14 and C-13 UBT to detect H. pylori infection is not significantly different, but the value of C-14 UBT

  5. Writable and erasable PPV medium by irradiation at 365 nm

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyuki [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)], E-mail: h-mochizuki@aist.go.jp; Mizokuro, Toshiko; Tanigaki, Nobutaka; Hiraga, Takashi [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)

    2008-03-03

    Dopings of vaporized cis-1,2-dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl) ethane (CMTE) into poly(methyl methacrylate) (PMMA), polystyrene, and polycarbonate were performed by a vacuum process, and the doping behaviors of CMTE were evaluated. Among the matrix polymers, PMMA was dispersed CMTE densely in its surface region. By using the CMTE-doped PMMA, we could fabricate a novel rewritable medium: a multi-layered film was prepared from over-coating of CMTE-doped PMMA onto poly(p-phenylene vinylene) (PPV) film, which set on a transparent substrate. Image storage could be performed upon irradiation at 365 nm at the side of CMTE/PMMA layer: color of the irradiated area changed a light yellow to a red due to photo-isomerization of CMTE. Next, upon irradiation at 365 nm at the side of the transparent substrate, PPV emitted a green fluorescence at around 530 nm, and the CMTE absorbed the emission from PPV causing image-erasure based on back-isomerization of CMTE.

  6. Comparative evaluation of sonographic ovarian morphology of Indian women with polycystic ovary syndrome versus those of normal women

    Directory of Open Access Journals (Sweden)

    Sanjeed Ahmed

    2014-01-01

    Full Text Available Objectives: To study ovarian morphology by ultrasound in women with or without polycystic ovary syndrome (PCOS and to establish cut-off values of these parameters in Indian women with PCOS. Materials and Methods: A total of 119 consecutive women diagnosed PCOS and 77 apparently healthy women were enrolled. Transabdominal ultrasound examination was carried out to assess ovarian volume, stromal echogenecity, follicle number and size. Cut-off values of the above ovarian parameters with sensitivity, specificity, positive predictive value (PPV and negative predictive values (NPV were calculated. Results: Sensitivity of 79.49% and specificity of 90.67% was achieved with a cut-off of 8 mL as ovarian volume. A cut-off value of 9 follicles to distinguish between PCOS and control women yielded a sensitivity of 82.35% and specificity of 92.0% while as a follicular size of 5 mm yielded sensitivity and specificity of 74.67% and 78.15% respectively. With all the three parameters sensitivity was 87.39% and specificity 87.84% with 92.04% PPV and 81.25% NPV. Conclusion: Using two or three sonographic criteria in combination improves sensitivity and helps diagnose additional patients with PCOS. Our results are at variance with the established cut-off values highlighting the fact that American Society for Reproductive Medicine consensus cut-off values are not reproducible in Indian context.

  7. The Predictive Value of Scores Used in Intensive Care Unit for Burn Patients Prognostic.

    Science.gov (United States)

    Novac, M; Dragoescu, Alice; Stanculescu, Andreea; Duca, Lucica; Cernea, Daniela

    2014-01-01

    Statistical evaluation of the prognosis of burned patients based on the analysis of prognostic scores as quickly and easily obtainable that track the evolution of burned patient in ICU. Material / Methods: The prospective study included 92 patients were performed with severe burns on 35-67% body surface large area, aiming to establish a cut-off score for each studied and statistically significant prognostic parameter for assessing the risk of mortality. The control group was represented by 20 patients with burns on the body surface of 0.05) sex (male / female), but we had p cut-off. Quantification of variables by calculating the area under the ROC curve (AUC), sensitivity and sensitivity, positive predictive value (PPV) and negative predictive value (NPV), allowed a better appreciation of these prognostic scores. These systems applicable to the burned patient scores, making a cut-off of each index / mortality probability score, he can manifest usefulness in medical decision making process and strategy to reduce the risk of death in patients with severe burns.

  8. Use of dynamic CT in acute respiratory distress syndrome (ARDS) with comparison of positive and negative pressure ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Helm, Emma; Babyn, Paul [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Talakoub, Omid; Alirezaie, Javad [Ryerson University, Department of Electrical and Computer Engineering, Toronto, ON (Canada); Grasso, Francesco; Engelberts, Doreen; Kavanagh, Brian P. [Hospital for Sick Children and the University of Toronto, Departments of Anesthesia and Critical Care Medicine and the Program in Pulmonary and Experimental Medicine, Toronto (Canada)

    2009-01-15

    Negative pressure ventilation via an external device ('iron lung') has the potential to provide better oxygenation with reduced barotrauma in patients with ARDS. This study was designed to see if oxygenation differences between positive and negative ventilation could be explained by CT. Six anaesthetized rabbits had ARDS induced by repeated saline lavage. Rabbits were ventilated with positive pressure ventilation (PPV) and negative pressure ventilation (NPV) in turn. Dynamic CT images were acquired over the respiratory cycle. A computer-aided method was used to segment the lung and calculate the range of CT densities within each slice. Volumes of ventilated lung and atelectatic lung were measured over the respiratory cycle. NPV was associated with an increased percentage of ventilated lung and decreased percentage of atelectatic lung. The most significant differences in ventilation and atelectasis were seen at mid-inspiration and mid-expiration (ventilated lung NPV=61%, ventilated lung PPV=47%, p<0.001; atelectatic lung NPV=10%, atelectatic lung PPV 19%, p<0.001). Aeration differences were not significant at end-inspiration. Dynamic CT can show differences in lung aeration between positive and negative ventilation in ARDS. These differences would not be appreciated if only static breath-hold CT was used. (orig.)

  9. Usefulness of estimation of blood procalcitonin concentration versus C-reactive protein concentration and white blood cell count for therapeutic monitoring of sepsis in neonates

    Directory of Open Access Journals (Sweden)

    Agnieszka Kordek

    2014-12-01

    Full Text Available Aim: This study was intended to assess the clinical usefulness of blood procalcitonin (PCT concentrations for the diagnosis and therapeutic monitoring of nosocomial neonatal sepsis.Material/Methods: The enrolment criterion was sepsis clinically manifesting after three days of life. PCT concentrations were measured in venous blood from 52 infected and 88 uninfected neonates. The results were interpreted against C-reactive protein (CRP concentrations and white blood cell counts (WBC.Results: Differences between the two groups in PCT and CRP concentrations were highly significant. No significant differences between the groups were noted for WBC. The threshold value on the receiver operator characteristic curve was 2.06 ng/mL for PCT (SE 75%; SP 80.68%; PPV 62.22%; NPV 88.75%; AUC 0.805, 5.0 mg/L for CRP (SE 67.44%; SP 73.68%; PPV 42.02%; NPV 88.89%; AUC 0.801, and 11.9 x109/L for WBC (SE 51.16%; SP 50.68%; PPV 23.16%; NPV 78.13%; AUC 0.484. Procalcitonin concentrations decreased 24 hours after initiation of antibiotic therapy and reverted to the control level after 5-7 days. C-reactive protein concentrations began to decline after two days of antibiotic therapy but were still higher than in the control group after 5-7 days of treatment. No significant changes in WBC during the treatment were observed.Conclusions: Procalcitonin concentrations in blood appear to be of use for the diagnosis and therapeutic monitoring of nosocomial infections in neonates as this parameter demonstrates greater sensitivity and specificity than C-reactive protein. White blood cell counts appear to be of little diagnostic value in the early phase of infection or for therapeutic monitoring.

  10. [Abnormal vaginal secretion: sensitivity, specificity and concordance between clinical and cytological diagnosis].

    Science.gov (United States)

    de Camargo, Kélvia Cristina; Alves, Rosane Ribeiro Figueiredo; Baylão, Luciano Augusto; Ribeiro, Andrea Alves; Araujo, Nadja Lindany Alves de Souza; Tavares, Suelene Brito do Nascimento; dos Santos, Sílvia Helena Rabelo

    2015-05-01

    To estimate the prevalence of bacterial vaginosis (BV), candidiasis and trichomoniasis and compare the findings of physical examination of the vaginal secretion with the microbiological diagnosis obtained by cytology study of a vaginal smear using the Papanicolaou method. A cross-sectional study of 302 women aged 20 to 87 years, interviewed and submitted to a gynecology test for the evaluation of vaginal secretion and collection of a cytology smear, from June 2012 to May 2013. Sensitivity analyses were carried out and specificity, positive predictive value (PPV) and negative predictive value (NPV) with their respective 95%CI were determined to assess the accuracy of the characteristics of vaginal secretion in relation to the microbiological diagnosis of the cytology smear . The kappa index (k) was used to assess the degree of agreement between the clinical features of vaginal secretion and the microbiological findings obtained by cytology. RESULTS The prevalence of BV, candidiasis and trichomoniasis was 25.5, 9.3 and 2.0%, respectively. The sensitivity, specificity, PPV and NPV of the clinical characteristics of vaginal secretion for the cytological diagnosis of BV were 74, 78.6, 54.3 and 89.9%, respectively. The sensitivity, specificity, PPV and the NPV of the clinical characteristics of vaginal secretion for the cytological diagnosis of candidiasis were 46.4, 86.2, 25.5 and 94%, respectively. The correlation between the clinical evaluation of vaginal secretion and the microbiological diagnosis of BV, candidiasis and trichomoniasis, assessed by the kappa index, was 0.47, 0.23 and 0.28, respectively. CONCLUSION The most common cause of abnormal vaginal secretion was BV. The clinical evaluation of vaginal secretion presented amoderate to weak agreement with the microbiological diagnosis, indicating the need for complementary investigation of the clinical findings of abnormal vaginal secretion.

  11. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta.

    Science.gov (United States)

    Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara

    2015-01-01

    The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental mRNA in maternal plasma. Based on the findings at cesarean delivery and histological examination, patients were divided into two groups of women with and without placenta accrete. To compare of the mean of mRNA levels between the two groups we used independent t-test and to compare of the mean of age and gestational age at sonography we used Mann-Whitney test. For determination of sensitivity and specificity and the cut-off point of mRNA levels we used the receiver operating characteristic curve. A total of 50 women with a mean age of 30.24 ± 4.905 years entered the study and 12 (24%) patients were diagnosed with placenta accreta. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasound were 83.3%, 78.9%, 56% and 94%, respectively. Results of our study showed if we consider a cut-off point equal to 3.325, with sensitivity and specificity of 0.917 and 0.789, respectively and the sensitivity, specificity, PPV and NPV of mRNA with were cut-off point of 3.325 were 91.7%, 78.9%, 57.9% and 96.8%, respectively. Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta.

  12. Double-labelling immunohistochemistry for MGMT and a “cocktail” of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours

    Science.gov (United States)

    2013-01-01

    Background Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Results Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Conclusions Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard. PMID:24252243

  13. Diagnosis of Obstructive Sleep Apnea Using Pulse Oximeter Derived Photoplethysmographic Signals

    Science.gov (United States)

    Romem, Ayal; Romem, Anat; Koldobskiy, Dafna; Scharf, Steven M.

    2014-01-01

    Objectives: Increasing awareness of the high prevalence of obstructive sleep apnea (OSA) and its impact on health in conjunction with high cost, inconvenience, and short supply of in-lab polysomnography (PSG) has led to the development of more convenient, affordable, and accessible diagnostic devices. We evaluated the reliability and accuracy of a single-channel (finger pulse-oximetry) photoplethysmography (PPG)-based device for detection of OSA (Morpheus Ox). Methods: Among a cohort of 73 patients referred for in-laboratory evaluation of OSA, 65 were simultaneously monitored with the PPG based device while undergoing PSG. Among these, 19 had significant cardiopulmonary comorbidities. Using the PSG as the “gold standard,” the sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), as well as the positive likelihood ratio (+LR) for an apnea hypopnea index (AHI)PSG > 5/h and AHIPSG > 15/h were calculated for the PPG. Results: Valid results were available for 65 subjects. Mean age: 52.1 ± 14.2, Male: 52%, and BMI: 36.3 ± 9.7 kg/m2. Positive correlation was found between PPG-derived and PSG-derived AHI (r = 0.81, p 5/h, sensitivity was 80%, specificity 86%, PPV 93%, NPV 68%, and +LR was 5.9. For AHIPSG > 15/h, sensitivity was 70%, specificity 91%, PPV 80%, NPV 85%, and +LR was 7.83. The corresponding areas under the receiver operator curves were 0.91 and 0.9. Conclusions: PPG-derived data compare well with simultaneous in-lab PSG in the diagnosis of suspected OSA among patients with and without cardiopulmonary comorbidities. Citation: Romem A; Romem A; Koldobskiy D; Scharf SM. Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals. J Clin Sleep Med 2014;10(3):285-290. PMID:24634626

  14. Accuracy of non-arthrographic 3T MR imaging in evaluation of intra-articular pathology of the hip in femoroacetabular impingement

    Energy Technology Data Exchange (ETDEWEB)

    Linda, Dorota D. [University of Toronto, Department of Medical Imaging, Joint Department of Medical Imaging, Division of Musculoskeletal Imaging, Toronto (Canada); Mount Sinai Hospital, Toronto, ON (Canada); Naraghi, Ali; White, Lawrence M. [University of Toronto, Department of Medical Imaging, Joint Department of Medical Imaging, Division of Musculoskeletal Imaging, Toronto (Canada); Murnaghan, Lucas; Whelan, Daniel [University of Toronto, Department of Surgery, Division of Orthopedics, Toronto (Canada)

    2017-03-15

    To investigate the accuracy of non-arthrographic 3-T MRI compared to hip arthroscopy in the assessment of labral and cartilaginous pathology in patients with suspected FAI. Following IRB approval and waived consent, 42 consecutive cases of suspected FAI with non-arthrographic 3-T MRI and arthroscopy of the hip were reviewed. High-resolution TSE MR imaging was evaluated in consensus by two musculoskeletal radiologists, blinded to arthroscopic findings, for the presence of labral tears and articular cartilage lesions. Acetabular cartilage was categorized as normal, degeneration/fissuring, delamination, or denudation. MRI findings were compared to arthroscopy. Sensitivity, specificity, accuracy, and predictive values for MRI were calculated using arthroscopy as the standard of reference. Forty-two hips in 38 patients with a mean age of 29 (range 13-45 years) were assessed. Mean interval between MRI and arthroscopy was 154 days (range 27-472 days). MRI depicted 41 cases with labral tears (sensitivity 100%, specificity 50%, accuracy 98%, PPV 98%, NPV 100%), 11 cases with femoral cartilage abnormalities (sensitivity 85%, specificity 100%, accuracy 95%, PPV 100%, NPV 94%), and 36 cases with acetabular cartilage lesions (sensitivity 94% specificity 67%, accuracy 90%, PPV 94%, NPV 67%). Of the 36 cases with acetabular cartilage lesions on MRI, 7 were characterized as degeneration/fissuring, 26 as delamination, and 3 as denudation, with discordant results between MRI and arthroscopy for grading of articular cartilage in ten cases. Non-arthrographic 3-T MR imaging is a highly accurate technique for evaluation of the labrum and cartilage in patients with clinically suspected FAI. (orig.)

  15. Accuracy of non-arthrographic 3T MR imaging in evaluation of intra-articular pathology of the hip in femoroacetabular impingement

    International Nuclear Information System (INIS)

    Linda, Dorota D.; Naraghi, Ali; White, Lawrence M.; Murnaghan, Lucas; Whelan, Daniel

    2017-01-01

    To investigate the accuracy of non-arthrographic 3-T MRI compared to hip arthroscopy in the assessment of labral and cartilaginous pathology in patients with suspected FAI. Following IRB approval and waived consent, 42 consecutive cases of suspected FAI with non-arthrographic 3-T MRI and arthroscopy of the hip were reviewed. High-resolution TSE MR imaging was evaluated in consensus by two musculoskeletal radiologists, blinded to arthroscopic findings, for the presence of labral tears and articular cartilage lesions. Acetabular cartilage was categorized as normal, degeneration/fissuring, delamination, or denudation. MRI findings were compared to arthroscopy. Sensitivity, specificity, accuracy, and predictive values for MRI were calculated using arthroscopy as the standard of reference. Forty-two hips in 38 patients with a mean age of 29 (range 13-45 years) were assessed. Mean interval between MRI and arthroscopy was 154 days (range 27-472 days). MRI depicted 41 cases with labral tears (sensitivity 100%, specificity 50%, accuracy 98%, PPV 98%, NPV 100%), 11 cases with femoral cartilage abnormalities (sensitivity 85%, specificity 100%, accuracy 95%, PPV 100%, NPV 94%), and 36 cases with acetabular cartilage lesions (sensitivity 94% specificity 67%, accuracy 90%, PPV 94%, NPV 67%). Of the 36 cases with acetabular cartilage lesions on MRI, 7 were characterized as degeneration/fissuring, 26 as delamination, and 3 as denudation, with discordant results between MRI and arthroscopy for grading of articular cartilage in ten cases. Non-arthrographic 3-T MR imaging is a highly accurate technique for evaluation of the labrum and cartilage in patients with clinically suspected FAI. (orig.)

  16. CdWO{sub 4}-on-MEH-PPV:PS as a candidate for real-time dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.M. [Laboratory of Polymers and Electronic Properties of Materials, UFOP, 35400-000 (Brazil); Novais, S.M.V.; Silva, E.S.S. [Group of Advanced Ceramic Materials, UFS, 49100-000 (Brazil); Schimitberger, T. [Laboratory of Polymers and Electronic Properties of Materials, UFOP, 35400-000 (Brazil); Macedo, Z.S. [Group of Advanced Ceramic Materials, UFS, 49100-000 (Brazil); Bianchi, R.F., E-mail: bianchi@iceb.ufop.br [Laboratory of Polymers and Electronic Properties of Materials, UFOP, 35400-000 (Brazil)

    2012-10-15

    We report on the investigations about the modification of optical properties induced by X-rays onto film detectors of cadmium tungstate (CdWO{sub 4}), poly[2-methoxy-5(2 Prime -ethylhexyloxy)-p-phenylenevinylene] (MEH-PPV) and polystyrene (PS) This device takes advantage of reduction of spectral overlap between the radioluminescence (RL) of CdWO{sub 4} and the absorption of MEH-PPV as it is exposed to radiation, forming the basis of a new dosimeter that is capable of converting the orange-red radioluminescence of PS:MEH-PPV:CdWO{sub 4} into green. We propose an explanation of the optical processes occurring in MEH-PPV:CdWO{sub 4} in terms of the radiation hardness of CdWO{sub 4} combined to the RL-induced degradation of MEH-PPV. Highlights: Black-Right-Pointing-Pointer Thin composite film dosimeters using a combination of a scintillator crystal and a light-emitting polymer. Black-Right-Pointing-Pointer A X-ray dose detector based on MEH-PPV/CdWO{sub 4} materials which are rarely seen together. Black-Right-Pointing-Pointer A new smart, disposable and easy-to-read organic-inorganic radiation detector.

  17. Morphological, structural and optical properties of MEH-PPV: PC70BM nanocomposite film

    Science.gov (United States)

    Mhamdi, Asya; Sweii, Fatma ben Slama; Saidi, Hamza; Saidi, Faouzi; Bouazizi, Abdelaziz

    2018-05-01

    In this report, the influence of annealing temperature and spin coating speed on the structural and morphological properties of a blend of poly (2-methoxy-5-(2-ethyl-oxy)-p-phenylene-vinylene) (MEH-PPV) and [6-6]-phenyl-C71-butyric acid methyl ester (PC70BM) layer has been investigated. The photoactive layer (MEH-PPV: PC70BM) was deposited on ZnO film deposited on top of indium tin oxide (ITO) substrate by spin-coating. The effect of spin coating speed via atomic force microscope (AFM) leads to conclude that high speed is favorable for a good homogeneity of the film surface and good aggregates dispersion. The optimized structure was studied by varying the annealing temperatures using X-ray diffraction (XRD). The XRD analysis indicates that annealing treatment promoted the ordered aggregation and crystallization of MEH-PPV: PC70BM films. Indeed, the blend ratio effect on the optical properties of MEH-PPV: PC70BM thin film was investigated. While, the effect of incorporation of PC70BM on the optical properties was studied using UV-Vis and photoluminescence (PL) measurement. We conclude that MEH-PPV: PC70BM (1:3) film leads to high charge transfer rate.

  18. Diagnostic value of 99mTc-ethambutol scintigraphy in tuberculosis: compared to microbiological and histopathological tests.

    Science.gov (United States)

    Kartamihardja, A H S; Kurniawati, Y; Gunawan, R

    2018-01-01

    Tuberculosis (TB) still remains the world's endemic infection. TB affects the lungs and any part of the body other than the lung. The diagnosis of TB has not changed much over the decades. Ethambutol is one of the first line treatments for TB. It can be labeled using 99m Tc. 99m Tc-ethambutol will be accumulated in the site of TB lesion and can be imaged using gamma camera. The aim of this study was to evaluate the diagnostic value of 99m Tc-ethambutol scintigraphy in detecting and localizing of TB. Retrospective cross-sectional study was done. Subjects were patients suspected of having TB infection. Whole body and SPECT-CT imaging at the suspected area was done 1 and 4 h after injection of 370-555 MBq 99m Tc-ethambutol. 99m Tc-ethambutol scintigraphy was analyzed visually. The results were compared with that of histopathological or microbiological tests. Statistical analysis was done to determine the sensitivity, specificity, PPV, NPV and accuracy. One hundred and sixty-eight subjects were involved in this study. There were 110 men and 58 women with mean age of 34.52 ± 11.94 years. There were concordance results in 156 (92.86%) and discordant in 12 (7.14%) subjects between 99m Tc-ethambutol scintigraphy and histopathological or microbiological result. The sensitivity, specificity, PPV, NPV and accuracy of 99m Tc-ethambutol scintigraphy in the diagnosis of pulmonary TB were 93.9, 85.7, 93.9, 85.7 and 91.4%, respectively, for extra-pulmonary TB 95.5, 77.8, 97.9, 63.6, and 85.1%, respectively, and for total tuberculosis 94.9, 83.3, 96.3, 78.1 and 92.8%, respectively. There was no side effect observed in this study. 99m Tc-ethambutol scintigraphy is a useful diagnostic imaging technique to detect and localize intra- and extra-pulmonary TB. It is safe to be performed even in pediatric patient. Consuming ethambutol less than 2 weeks did not influence the result.

  19. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    Directory of Open Access Journals (Sweden)

    Linda C. Rogers

    2016-01-01

    Full Text Available Objective Accurate and timely diagnosis of rupture of membranes (ROM is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus® in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy. Results Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%, specificity (94.8% vs. 79.3%, PPV (75% vs. 36.8%, NPV (100% vs. 95.8%, and accuracy (95.5% vs. 79.1%. Conclusions The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

  20. Comparison between arthroscopy and 3 dimensional double echo steady state 3D-DESS sequences in magnetic resonance imaging of internal derangements of the knee

    International Nuclear Information System (INIS)

    Dongola, Nagwa A.; Gishen, Philip

    2004-01-01

    This study was performed with the aim of evaluating the usefulness of 3 dimensional double-echo steady state sequences in examining the internal derangements of the knee. Arthroscopy was used as a referral standard. The study was performed in the Radiology and Arthroscopy Departments of Kings College Hospital, London, United Kingdom, during a 6-month period from January 1997 to June 1997. All patients who had knee magnetic resonance imaging within 3 months of arthroscopy were retrospectively studied. Thirty-three patients fulfilled these criteria and were selected. Three dimensional double-echo steady state sequences produced sensitivity for detecting meniscal tears of 87.5% for medial menisci (MM) and 75% for lateral menisci (LM). Specificity was 76% for MM and 96% for LM; positive predictive value (PPV) was 46.1% for MM and 85.7% for LM and negative predictive value (NPV) of 95% for MM and 96% for LM. The sensitivity for the anterior cruciate ligament was 83.3%, specificity was 77.7%, PPV was 45.4% and NPV was 95.4%. Three dimensional double-echo steady state sequences are useful in evaluating internal derangement of the knee, especially in advanced cartilage lesions. (author)

  1. Retinopathy diabetic screening by non-mydriatic retinography: concordance between primary care physicians, nurses and ophthalmologists.

    Science.gov (United States)

    Rodríguez Villa, Susana; Suárez Muñiz, María Teresa; De Dios Del Valle, Ricardo; Alonso Álvarez, Crisanto

    To compare the evaluation of retinographies by a teleophthalmology nurse and primary care physicians (PCP) with an ophthalmologist referral hospital (gold standard). Cross-sectional study on a random sample of 337 patients on the teleophthalmology programme from January 2010 to January 2015. We analyzed the diagnostic evaluation (whether or not it presented findings of RD) and the therapeutic assessment (whether or not referral to the opthalmology department was needed) which were conducted independently on the sample retinographies by the PCP, a nurse and an ophthalmologist (gold standard). Reliability and concordance between the gold standard and the PCP and the nurse were checked and the statistical analyses were supported using SPSSv.23.00 software and diagnostic test reliability calculators (EPIDAT 4.1). In the diagnosis of RD, the nurse presented: sensitivity (S): 0.96; specificity (Sp): 0.89; PPV: 0.58; NPV: 0.99; Kappa index: 0.67 and PCP: S: 0.98; Sp: 0.99; PPV: 0.96; NPV: 0.99; Kappa index: 0.96. In the referral to ophthalmology assessed by the nurse: S: 0.83; Sp: 0.83; PPV: 0.51; NPV: 0.96; Kappa Index: 0.53 and PCP: S: 0.62; Sp: 0.76; PPV: 0.36; NPV: 0.90; Kappa index: 0.29. A nursing teleophthalmology programme could perform population screening for RD with the same quality as PCP. This would increase coverage, in addition to providing better use of resources by avoiding intermediate patient appointments through PCP and increased health savings. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  2. Nucleic Acid Amplification Testing and Sequencing Combined with Acid-Fast Staining in Needle Biopsy Lung Tissues for the Diagnosis of Smear-Negative Pulmonary Tuberculosis.

    Directory of Open Access Journals (Sweden)

    Faming Jiang

    Full Text Available Smear-negative pulmonary tuberculosis (PTB is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB staining of needle biopsy lung tissues for patients with suspected smear-negative PTB.Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR. For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM. The sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination.Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124. Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB for the diagnosis of smear-negative were 61.7% (82/133, 100% (48/48, 100% (82/82, 48.5% (48/181, and 71.8% (130/181, respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133, 95.8% (46/48, 98.3% (119/121, and 76.7% (46/60, respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181] than histological acid-fast staining (71.8% [130/181], P < 0.001. Parallel testing of histological AFB staining and PCR showed the

  3. Thymosin From Bombyx mori Is Down-Regulated in Expression by BmNPV Exhibiting Antiviral Activity.

    Science.gov (United States)

    Zhang, Chen; Wang, Yongdi; Fang, Qiang; Xu, Minlin; Lv, Mengyuan; Liao, Jinxu; Li, Si; Nie, Zuoming; Zhang, Wenping

    2016-01-01

    Thymosins have been highly conserved during evolution. These hormones exist in many animal species and play an essential role in many biological events. However, little is known regarding the physiological function of silkworm Bombyx mori thymosin (BmTHY). In this study, we investigated the expression pattern of BmTHY in a Bombyx mori larval ovarian cell line (BmN) challenged with Bombyx mori nuclear polyhydrosis virus (BmNPV) and the antiviral effect of recombinant BmTHY (rBmTHY) for Bombyx mori against BmNPV. Western-blot assay and qRT-PCR analysis revealed that the level of BmTHY protein expression and transcription decreased over time when BmN cells were infected by BmNPV. Treatment with endotoxin-free rBmTHY led to a significant reduction in viral titer in the supernatant of BmN cells challenged with BmNPV. The results from antiviral tests performed in vitro and in vivo showed that endotoxin-free rBmTHY improved the survival rate of Bombyx mori infected with BmNPV. These findings suggest that BmTHY exerts immunomodulatory effects on Bombyx mori, rendering them resistant to viral infection. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America.

  4. Grading of Cerebral Glioma with Multiparametric MR Imaging and {sup 18}F-FDG-PET: Concordance and Accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Kim, Ji-hoon; Sohn, Chul-Ho; Choi, Seung Hong; Yun, Tae Jin; Song, Yong Sub [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Kang, Won Jun [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Yonsei University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Eun, Yong [Seoul National University, College of Medicine, Seoul (Korea, Republic of); Chang, Kee-Hyun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Soonchunhyang University Bucheon Hospital, Department of Radiology, Bucheon (Korea, Republic of)

    2014-02-15

    To retrospectively evaluate concordance rates and predictive values in concordant cases among multiparametric MR techniques and FDG-PET to grade cerebral gliomas. Multiparametric MR imaging and FDG-PET were performed in 60 consecutive patients with cerebral gliomas (12 low-grade and 48 high-grade gliomas). As the dichotomic variables, conventional MRI, minimum apparent diffusion coefficient in diffusion-weighted imaging, maximum relative cerebral blood volume ratio in perfusion-weighted imaging, choline/creatine ratio and (lipid and lactate)/creatine ratio in MR spectroscopy, and maximum standardised uptake value ratio in FDG-PET in low- and high-grade gliomas were compared. Their concordance rates and positive/negative predictive values (PPV/NPV) in concordant cases were obtained for the various combinations of multiparametric MR techniques and FDG-PET. There were significant differences between low- and high-grade gliomas in all techniques. Combinations of two, three, four, and five out of the five techniques showed concordance rates of 77.0 ± 4.8 %, 65.5 ± 4.0 %, 58.3 ± 2.6 % and 53.3 %, PPV in high-grade concordant cases of 97.3 ± 1.7 %, 99.1 ± 1.4 %, 100.0 ± 0 % and 100.0 % and NPV in low-grade concordant cases of 70.2 ± 7.5 %, 78.0 ± 6.0 %, 80.3 ± 3.4 % and 80.0 %, respectively. Multiparametric MR techniques and FDG-PET have a concordant tendency in a two-tiered classification for the grading of cerebral glioma. If at least two examinations concordantly indicated high-grade gliomas, the PPV was about 95 %. (orig.)

  5. Sinusoidal obstructive syndrome diagnosed with superparamagnetic iron oxide-enhanced magnetic resonance imaging in patients with chemotherapy-treated colorectal liver metastases.

    Science.gov (United States)

    Ward, Janice; Guthrie, James A; Sheridan, Maria B; Boyes, Sheila; Smith, Jonathan T; Wilson, Daniel; Wyatt, Judy I; Treanor, Darren; Robinson, Philip J

    2008-09-10

    To assess the predictive value of superparamagnetic iron oxide (SPIO) -enhanced T2-weighted gradient echo (GRE) imaging to determine the presence and severity of sinusoidal obstructive syndrome (SOS). Sixty hepatic resection patients with colorectal metastases treated with chemotherapy underwent unenhanced magnetic resonance imaging (MRI) followed by T2-weighted GRE sequences obtained after SPIO. The images were reviewed in consensus by two experienced observers who determined the presence and severity of linear and reticular hyperintensities, indicating SOS-type liver injury, using a 4-point ordinal scale. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% CIs for the detection of SOS were calculated. Twenty-four of 60 patients had moderate to severe SOS on MRI. MRI achieved a sensitivity of 87% (95% CI, 66% to 97%), specificity of 89% (95% CI, 75% to 97%), PPV of 83% (95% CI, 63% to 95%), and NPV of 92% (95% CI, 77% to 98%). SOS was never found at surgery or histology in patients whose background liver parenchyma was normal on SPIO-enhanced MRI. SOS is present in a significant proportion of patients with treated colorectal metastases and is effectively detected on SPIO-enhanced T2-weighted GRE images.

  6. Preoperative Molecular Markers in Thyroid Nodules.

    Science.gov (United States)

    Sahli, Zeyad T; Smith, Philip W; Umbricht, Christopher B; Zeiger, Martha A

    2018-01-01

    The need for distinguishing benign from malignant thyroid nodules has led to the pursuit of differentiating molecular markers. The most common molecular tests in clinical use are Afirma ® Gene Expression Classifier (GEC) and Thyroseq ® V2. Despite the rapidly developing field of molecular markers, several limitations exist. These challenges include the recent introduction of the histopathological diagnosis "Non-Invasive Follicular Thyroid neoplasm with Papillary-like nuclear features", the correlation of genetic mutations within both benign and malignant pathologic diagnoses, the lack of follow-up of molecular marker negative nodules, and the cost-effectiveness of molecular markers. In this manuscript, we review the current published literature surrounding the diagnostic value of Afirma ® GEC and Thyroseq ® V2. Among Afirma ® GEC studies, sensitivity (Se), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV) ranged from 75 to 100%, 5 to 53%, 13 to 100%, and 20 to 100%, respectively. Among Thyroseq ® V2 studies, Se, Sp, PPV, and NPV ranged from 40 to 100%, 56 to 93%, 13 to 90%, and 48 to 97%, respectively. We also discuss current challenges to Afirma ® GEC and Thyroseq ® V2 utility and clinical application, and preview the future directions of these rapidly developing technologies.

  7. Solitary Pulmonary Nodule on Helical Dynamic CT Scans: Analysis of the Enhancement Patterns Using a Computer-Aided Diagnosis (CAD) System

    International Nuclear Information System (INIS)

    Choi, Eun Jung; Jin, Gong Yong; Han, Young Min; Lee, Young Sun; Kweon, Keun Sang

    2008-01-01

    We wanted to investigate the usefulness of a computer-aided diagnosis (CAD) system in assisting radiologists to diagnosis malignant solitary pulmonary nodules (SPNs), as compared with diagnosing SPNs with using direct personal drawing. Forty patients with SPNs were analyzed. After the pre-contrast scan was performed, an additional ten series of post-contrast images were obtained at 20-second intervals. Two investigators measured the attenuation values of the SPNs: a radiologist who drew the regions of interest (ROIs), and a technician who used a CAD system. The Bland and Altman plots were used to compare the net enhancement between a CAD system and direct personal drawing. The diagnostic characteristics of the malignant SPNs were calculated by considering the CAD and direct personal drawing and with using Fisher's exact test. On the Bland and Altman plot, the net enhancement difference between the CAD system and direct personal drawing was not significant (within ± 2 standard deriation). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosing malignant SPNs using CAD was 92%, 85%, 75%, 96% and 88%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of diagnosing malignant SPNs using direct drawing was 92%, 89%, 79%, 92% and 88%, respectively. The CAD system was a useful tool for diagnosing malignant SPNs

  8. Diagnostic accuracy of circulating thyrotropin receptor messenger RNA combined with neck ultrasonography in patients with Bethesda III-V thyroid cytology.

    Science.gov (United States)

    Aliyev, Altay; Patel, Jinesh; Brainard, Jennifer; Gupta, Manjula; Nasr, Christian; Hatipoglu, Betul; Siperstein, Allan; Berber, Eren

    2016-01-01

    The aim of this study was to analyze the usefulness of thyrotropin receptor messenger RNA (TSHR-mRNA) combined with neck ultrasonography (US) in the management of thyroid nodules with Bethesda III-V cytology. Cytology slides of patients with a preoperative fine needle aspiration (FNA) and TSHR-mRNA who underwent thyroidectomy between 2002 and 2011 were recategorized based on the Bethesda classification. Results of thyroid FNA, TSHR-mRNA, and US were compared with the final pathology. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. There were 12 patients with Bethesda III, 112 with Bethesda IV, and 58 with Bethesda V cytology. The sensitivity of TSHR-mRNA in predicting cancer was 33%, 65%, and 79 %, and specificity was 67%, 66%, and 71%, for Bethesda III, IV, and V categories, respectively. For the same categories, the PPV of TSHR-mRNA was 25%, 33%, and 79%, respectively; whereas the NPV was 75%, 88%, and 71%, respectively. The addition of neck US to TSHR-mRNA increased the NPV to 100% for Bethesda III, and 86%, for Bethesda IV, and 82% for Bethesda V disease. This study documents the potential usefulness of TSHR-mRNA for thyroid nodules with Bethesda III-V FNA categories. TSHR-mRNA may be used to exclude Bethesda IV disease. A large sample analysis is needed to determine its accuracy for Bethesda category III nodules. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA

    International Nuclear Information System (INIS)

    Haneder, Stefan; Attenberger, Ulrike I.; Riffel, Philipp; Henzler, Thomas; Schoenberg, Stefan O.; Michaely, Henrik J.

    2011-01-01

    To compare 3D non-enhanced ECG-gated inflow-dependent MRA (NE-MRA) vs. continuous table movement (CTM) MR-angiography and time-resolved TWIST-MRA in the calf station at 3.0 T in a clinical patient collective. 36 patients (27 male/9 female, 66.1 ± 14.4 years) with PAOD (stage II-IV) underwent during a single MRI: NE-MRA, contrast-enhanced CTM-MRA and TWIST-MRA with a single dose of a gadolinium-based contrast agent. The image quality (IQ) and the degree of stenoses were rated on a four-point scale. Positive (PPV) and negative predictive values (NPV), sensitivity (SS) and specificity (SP) for stenoses detection were calculated for NE-MRA vs. CTM-MRA and vs. TWIST-MRA. Values were obtained for overall graduation of wall changes and for severe stenoses (>70%). With NE-MRA 122/288 segments were not assessable. Compared with CTM-MRA and TWIST-MRA the IQ was significantly inferior (p < 0.0001 to p = 0.0426). CTM-MRA/TWIST-MRA detected stenoses in 44.9%/46.1% of the segments, NE-MRA in 53.5%. SS/NPV of the NE-MRA ranged from 97.8 to 100%. The SP and PPV ranged from 72.7 to 85.5% and 66.7 to 78.2%. Contrast-enhanced MRA techniques are superior to NE-MRA regarding IQ and correct identification of stenoses. If technically successful, NE-MRA is characterised by high NPV and overestimation of the degree of stenoses. (orig.)

  10. Lithofacies modeling by multipoint statistics and economic evaluation by NPV volume for the early Cretaceous Wabiskaw Member in Athabasca oilsands area, Canada

    Directory of Open Access Journals (Sweden)

    Kwang Hyun Kim

    2018-03-01

    As Wabiskaw Member is frontier oilsands lease, it is impossible to evaluate the economics from production data or dynamic simulation. In this study, a dynamic steam assisted gravity drainage (SAGD performance indicator (SPIDER on the basis of reservoir characteristics is calculated to build 3D reservoir model for the evaluation of the SAGD feasibility in Wabiskaw Member. SPIDER depends on reservoir properties, economic limit of steam-oil ratio, and bitumen price. Reservoir properties like porosity, permeability, and water saturation are measured from 13 cores and calculated from 201 well-logs. Three dimensional volumes of reservoir properties are constructed mostly based on relationships among properties. Finally, net present value (NPV volume can be built by equation relating NPV and SPIDER. The economic area exceeding criterion of US$ 10,000 is identified, and the ranges of reservoir properties are estimated. NPV-volume-generation workflow from reservoir parameter to static model provides cost- and time- effective method to evaluate the oilsands SAGD project.

  11. Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis.

    Science.gov (United States)

    Zhou, Bang-Guo; Wang, Dan; Ren, Wei-Wei; Li, Xiao-Long; He, Ya-Ping; Liu, Bo-Ji; Wang, Qiao; Chen, Shi-Gao; Alizad, Azra; Xu, Hui-Xiong

    2017-08-01

    To evaluate the diagnostic performance of shear wave arrival time contour (SWATC) display for the diagnosis of breast lesions and to identify factors associated with the quality of shear wave propagation (QSWP) in breast lesions. This study included 277 pathologically confirmed breast lesions. Conventional B-mode ultrasound characteristics and shear wave elastography parameters were computed. Using the SWATC display, the QSWP of each lesion was assigned to a two-point scale: score 1 (low quality) and score 2 (high quality). Binary logistic regression analysis was performed to identify factors associated with QSWP. The area under the receiver operating characteristic curve (AUROC) for QSWP to differentiate benign from malignant lesions was 0.913, with a sensitivity of 91.9%, a specificity of 90.7%, a positive predictive value (PPV) of 74.0%, and a negative predictive value (NPV) of 97.5%. Compared with using the standard deviation of shear wave speed (SWS SD ) alone, SWS SD combined with QSWP increased the sensitivity from 75.8% to 93.5%, but decreased the specificity from 95.8% to 89.3% (P breast lesions.

  12. Correlation between physical examination and intraoperative findings in shoulder disease treated by arthroscopy. Statistical analysis of 150 patients.

    Science.gov (United States)

    García Parra, P; Anaya Rojas, M; Jiménez Bravo, B; González Oria, M O; Lisbona Muñoz, M; Gil Álvarez, J J; Cano Luis, P

    2016-01-01

    Only a few clinical exploratory manoeuvres are truly discriminatory and useful in shoulder disease. The aim of this study is to correlate the physical examination results of the shoulder with the true diagnosis found by arthroscopy. A retrospective case series of 150 patients with the most common surgical conditions of the shoulder. Data were collected on the suspicion of each pathology, the physical examination of the patient, and the actual discovery of the disease during arthroscopic surgery. The Bankart examination manoeuvres of the lesion show the best results, with a 92.1% positive prediction value (PPV), a 99.1% negative predictive value (NPV), followed by the impingement syndrome, with a PPV of 94.4%, and total cuff rupture with a PPV of 92.3%.Exploration of the superior labrum anterior to posterior (SLAP) lesion had an NPV of 99.1%. Physical examination is sufficient to diagnose or rule out Bankart. A positive physical examination provides the complete rupture of the rotator cuff, and requires further studies. The patients suspected of subacromial syndrome only need an NMR if the physical tests are negative. The conclusions drawn from this work can have a significant impact on both cost savings (by reducing forward tests), and saving time in certain cases in which, after appropriate physical examination, surgery may be indicated without losing time in intermediate steps. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients

    International Nuclear Information System (INIS)

    Riegger, Carolin; Heusner, Till A.; Koeninger, Angela; Kimmig, Rainer; Hartung, Verena; Bockisch, Andreas; Otterbach, Friedrich; Forsting, Michael; Antoch, Gerald

    2012-01-01

    Background. FDG-PET/CT is increasingly being used for breast cancer staging. Its diagnostic accuracy in comparison to ultrasound as the standard non-invasive imaging modality for the evaluation of axillary lymph nodes has yet not been evaluated. Purpose. To retrospectively compare the diagnostic value of full-dose, intravenously contrast-enhanced FDG-PET/CT and ultrasound for the detection of lymph node metastases in breast cancer patients. Material and Methods. Ninety patients (one patient with a bilateral carcinoma) (89 women, one man; mean age, 55.5 ± 16.6 years) suffering from primary breast cancer underwent whole-body FDG-PET/CT and axillary ultrasound. The ipsilateral axillary fossa (n = 91) was evaluated for metastatic spread. The sensitivity, specificity, the positive predictive value (PPV), negative predictive value (NPV), and accuracy of both methods were calculated. The sensitivity and accuracy were statistically compared using the McNemar Test (P <0.05). Analyses were made on a patient basis. The number of patients with extra-axillary locoregional lymph node metastases exclusively detected by FDG-PET/CT was evaluated. For axillary lymph node metastases histopathology served as the reference standard. Results. The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases were 54%, 89%, 77%, 74%, and 75%, respectively. For ultrasound it was 38%, 78%, 54%, 65%, and 62%, respectively. FDG-PET/CT was significantly more accurate than ultrasound for the detection of axillary lymph node metastases (P = 0.019). There was no statistically significant difference between the sensitivity of both modalities (P = 0.0578). FDG-PET/CT detected extra-axillary locoregional lymph node metastases in seven patients (8%) that had not been detected by another imaging modality. Conclusion. Though more accurate compared to ultrasound for evaluating the axillary lymph node status FDG-PET/CT is only as sensitive as

  14. The economic value of an investment in physiotherapy education: a net present value analysis

    OpenAIRE

    George Rivers; Jonathan Foo; Dragan Ilic; Peter Nicklen; Scott Reeves; Kieran Walsh; Stephen Maloney

    2015-01-01

    Questions: What is the economic value for an individual to invest in physiotherapy undergraduate education in Australia? How is this affected by increased education costs or decreased wages? Design: A cost-benefit analysis using a net present value (NPV) approach was conducted and reported in Australian dollars. In relation to physiotherapy education, the NPV represents future earnings as a physiotherapist minus the direct and indirect costs in obtaining the degree. Sensitivity analyses were ...

  15. Nucleic Acid Amplification Testing and Sequencing Combined with Acid-Fast Staining in Needle Biopsy Lung Tissues for the Diagnosis of Smear-Negative Pulmonary Tuberculosis.

    Science.gov (United States)

    Jiang, Faming; Huang, Weiwei; Wang, Ye; Tian, Panwen; Chen, Xuerong; Liang, Zongan

    2016-01-01

    Smear-negative pulmonary tuberculosis (PTB) is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB) staining of needle biopsy lung tissues for patients with suspected smear-negative PTB. Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR). For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination. Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124). Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB) for the diagnosis of smear-negative were 61.7% (82/133), 100% (48/48), 100% (82/82), 48.5% (48/181), and 71.8% (130/181), respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133), 95.8% (46/48), 98.3% (119/121), and 76.7% (46/60), respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181]) than histological acid-fast staining (71.8% [130/181]), P pulmonary tuberculosis. For patients with positive histological AFB and

  16. Nucleotide sequence of the coat protein gene of the Skierniewice isolate of plum pox virus (PPV)

    International Nuclear Information System (INIS)

    Wypijewski, K.; Musial, W.; Augustyniak, J.; Malinowski, T.

    1994-01-01

    The coat protein (CP) gene of the Skierniewice isolate of plum pox virus (PPV-S) has been amplified using the reverse transcription - polymerase chain reaction (RT-PCR), cloned and sequenced. The nucleotide sequence of the gene and the deduced amino-acid sequences of PPV-S CP were compared with those of other PPV strains. The nucleotide sequence showed very high homology to most of the published sequences. The motif: Asp-Ala-Gly (DAG), important for the aphid transmissibility, was present in the amino-acid sequence. Our isolate did not react in ELISA with monoclonal antibodies MAb06 supposed to be specific for PPV-D. (author). 32 refs, 1 fig., 2 tabs

  17. PP-O and PP-V, Monascus pigment homologues, production, and phylogenetic analysis in Penicillium purpurogenum.

    Science.gov (United States)

    Arai, Teppei; Kojima, Ryo; Motegi, Yoshiki; Kato, Jun; Kasumi, Takafumi; Ogihara, Jun

    2015-12-01

    The production of pigments as secondary metabolites by microbes is known to vary by species and by physiological conditions within a single strain. The fungus strain Penicillium purpurogenum IAM15392 has been found to produce violet pigment (PP-V) and orange pigment (PP-O),Monascus azaphilone pigment homologues, when grown under specific culture conditions. In this study, we analysed PP-V and PP-O production capability in seven strains of P. purpurogenum in addition to strain IAM15392 under specific culture conditions. The pigment production pattern of five strains cultivated in PP-V production medium was similar to that of strain IAM15392, and all violet pigments produced by these five strains were confirmed to be PP-V. Strains that did not produce pigment were also identified. In addition, two strains cultivated in PP-O production medium produced a violet pigment identified as PP-V. The ribosomal DNA (rDNA) internal transcribed spacer (ITS) region sequences from the eight P. purpurogenum strains were sequenced and used to construct a neighbor-joining phylogenetic tree. PP-O and PP-V production of P. purpurogenum was shown to be related to phylogenetic placement based on rDNA ITS sequence. Based on these results, two hypotheses for the alteration of pigment production of P. purpurogenum in evolution were proposed. Copyright © 2015 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  18. A new diagnostic tool for rapid and accurate detection of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    Ali Nour-Neamatollahi

    2018-03-01

    Full Text Available Mycobacterium tuberculosis, acid fast bacilli from the family of Mycobacteriaceae, is the causative agent of most cases of tuberculosis. Tuberculosis, as a communicable disease, remains a serious public health threat, killing more than one million people globally every year. Primary diagnosis of tuberculosis bacilli (TB relies mainly on microscopic detection of acid fast bacilli (AFB, but the method suffers from low sensitivity and the results largely depend on the technician’s skill. New diagnostic tools are necessary to be introduced for rapid and accurate detection of the bacilli in sputum samples. We, in collaboration with Anda Biologicals, have developed a new platform, named as “Patho-tb”, for rapid detection of AFB with high sensitivity and with low dependence on human skills. Evaluation of Patho-tb test performance was done in two settings: (1 primary field study conducted using 38 sputa from high TB prevalence area of Iran (Zabol city near to the Afghanistan border, and (2 main study conducted using 476 sputa from Tehran, capital of Iran. Patho-tb was applied for processed sputum samples in parallel with routine diagnostic methods (including AFB microscopy, culture and PCR. All test results were compared to final clinical diagnostic state of an individual and diagnostic sensitivity (DSe, specificity, positive predictive value, negative predictive value and accuracy of each test results were calculated using standard formulations. Analytical sensitivity and specificity of the Patho-tb test were also determined. Calculated values for five above mentioned parameters are as follows: for field study: AFB (DSe: 29.6, DSp: 81.8, PPV: 80, NPV: 23.1, AC: 44.7, Patho-tb (DSe: 63, DSp: 72.7, PPV: 85, NPV: 44.4, AC: 65.8, and for main study: AFB (DSe: 86.1, DSp: 99.4, PPV: 98.5, NPV: 93.9, AC: 95.2, Patho-tb (DSe: 97.4, DSp: 92.9, PPV: 86.5, NPV: 98.7, AC: 94.3. Reproducibility of Patho-tb test results were near to 100% (Cohen’s kappa value

  19. Histological study of SlNPV infection on body weight and peritrophic membrane damage of Spodoptera litura larvae

    Directory of Open Access Journals (Sweden)

    NANIN DIAH KURNIAWATI

    2010-11-01

    Full Text Available Sanjaya, Machmudin D, Kurniawati ND. 2010. Histological study of SlNPV infection on body weight and peritrophic membrane damage of Spodoptera litura larvae. Nusantara Bioscience 2: 135-140. The effect of SlNPV infection on body weight and peritrophic membrane damage of Spodoptera litura Fab. larvae has been carried out. The method was used Probit analysis, and based on LD 50 the virus was infected to know body weight and post infection damage.The damage of histological structure caused by SlNPV (0, 315, 390, 465, 540 dan 615 PIB/mL was investigated after 0, 12, 24, 72 and 96 hours post infection. The histological material was prepared by using parafin method after fixation with Bouin Solution, then slice into 7 um and colored with Hematoxilin-Eosin. The result showed that the exposure SlNPV cause decreasing food consumption especially on 540 PIB/mL give average rate as amount of 0.1675 mg. The descriptive obsevation on structural intact of peritrophic membrane histology caused by SlNPV infection shows a tendency to decrease, while in control, there was no damage at all. The longer the exposition of virion in the midgut lumen the more damage on peritrophic membrane occurred. The severest damage occurred 96 hour after infection. The result prove that haNPV virion can destroy hystological structure of midgut.

  20. Intra-prosthetic breast MR virtual navigation: a preliminary study for a new evaluation of silicone breast implants.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Capuano, Giulia; Rella, Leonarda; Scardapane, Arnaldo; Angelelli, Giuseppe; Stabile Ianora, Amato Antonio

    2013-10-01

    To assess the contribute of intra-prosthetic MRI virtual navigation for evaluating breast implants and detecting implant ruptures. Forty-five breast implants were evaluated by MR examination. Only patients with a clinical indication were assessed. A 1.5-T device equipped with a 4-channel breast coil was used by performing axial TSE-T2, axial silicone-only, axial silicone suppression and sagittal STIR images. The obtained dicom files were also analyzed by using virtual navigation software. Two blinded radiologists evaluated all MR and virtual images. Eight patients for a total of 13 implants underwent surgical replacement. Sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated for both imaging strategies. Intra-capsular rupture was diagnosed in 13 out of 45 (29%) implants by using MRI. Basing on virtual navigation, 9 (20%) cases of intra-capsular rupture were diagnosed. Sensitivity, specificity, accuracy, PPV and NPV values of 100%, 86%, 89%, 62% and 100%, respectively, were found for MRI. Virtual navigation increased the previous values up to 100%, 97%, 98%, 89% and 100%. Intra-prosthetic breast MR virtual navigation can represent an additional promising tool for the evaluation of breast implants being able to reduce false positives and to provide a more accurate detection of intra-capsular implant rupture signs. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Hemizona Assay and Sperm Penetration Assay in the Prediction of IVF Outcome: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Paraskevi Vogiatzi

    2013-01-01

    Full Text Available The limited predictive value of semen analysis in achieving natural conception or in IVF outcome confirms the need for sperm function tests to determine optimal management. We reviewed HZA and SPA predictive power in IVF outcome, with statistical significance of diagnostic power of the assays. HZA was readily efficient in predicting IVF outcome, while evident inconsistency among the studies analysed framed the SPA’s role in male fertility evaluation. Considerable variation was noted in the diagnostic accuracy values of SPA with wide sensitivity (52–100%, specificity (0–100%, and PPV (18–100% and NPV (0–100% together with fluctuation and notable differentiation in methodology and cutoff values employed by each group. HZA methodology was overall consistent with minor variation in cutoff values and oocyte source, while data analysis reported strong correlation between HZA results with IVF outcome, high sensitivity (75–100%, good specificity (57–100%, and high PPV (79–100% and NPV (68–100%. HZA correlated well with IVF outcome and demonstrated better sensitivity/specificity and positive/negative predictive power. Males with normal or slightly abnormal semen profiles could benefit by this intervention and could be evaluated prior to referral to assisted reproduction. HZA should be used in a sequential fashion with semen analysis and potentially other bioassays in an IVF setting.

  2. Diagnostic value of 99mTc-pertechnetate salivary gland scintigraphy (SGS) in Sjoegren's syndrome (SS). Comparative study with symptomatic non Sjoegren patients and healthy controls

    International Nuclear Information System (INIS)

    Lobo, G.; Ladron de Guevara, D.; Zerboni, A.; Aguilera, S.

    2002-01-01

    The aim of this study was to describe SGS findings in patients with SS, and to compare them with non Sjoegren symptomatic and healthy control individual, estimating performance of SGS in SS diagnosis. Materials and Method: Fifty three control individual (average age: 53.7 yr, range: 27-83 yr) and 169 patients with subjective xerostomia underwent 99mTc-pertechnetate scintigraphy. The symptomatic group consisted of: 112 patients with Sjoegren's syndrome (average age: 53.7 yr, range:16-81 yr) according to modifying European Classification Criteria, 42 patients with fibromyalgia (FM)(average age:48.2 yr, range:19-76 yr) who presented non-specific chronic sialadenitis or normal labial biopsy, and 15 patients with keratoconjunctivitis sicca (KS) (average age: 40.9 yr, range:23-57 yr). SGS was performed following i.v. injection of 10 mCi 99mTc-pertechnetate, in dynamic acquisition of 60 15-sec frames, and giving lemon juice orally at 20 min. Irregular regions of interest (ROI) over salivary glands and brain for background assessment were drawn, building time-activity curves. SGS was classified according to visual intensity of gland tracer uptake and excretion before and after lemon and curve evaluation, in: normal (intensity of gland uptake fourfold background activity, ascending curve with fast and profound fall after lemon) , mild alteration (light decrease in gland uptake or excretion, with a normal curve shape), moderate alteration (evident uptake and excretion decrease with a median Mita curve) and severe alteration (very low or absent uptake, flat or slope curve). Scintigraphic findings were compared with diagnosis, calculating positive (PPV) and negative predictive value (NPV) for SS. Results: The results of SGS according to diagnosis are presented. SS group had higher incidence of severe alterations (p<0.001) than each of other clinics groups and lower proportion of mild alterations (p:0.008) and normal scans (p:0.005) than both control and KS patients. The KS

  3. Comparison of single questions and brief questionnaire with longer validated food frequency questionnaire to assess adequate fruit and vegetable intake.

    Science.gov (United States)

    Cook, Amelia; Roberts, Kia; O'Leary, Fiona; Allman-Farinelli, Margaret Anne

    2015-01-01

    The aim of this study was to determine if a single question (SQ) for fruit and a SQ or five-item questionnaire for vegetable consumption (VFQ) could replace a longer food frequency questionnaire (FFQ) to screen for inadequate versus adequate intakes in populations. Participants (109) completed three test screeners: fruit SQ, vegetable SQ, and a five-item VFQ followed by the reference 74-item FFQ (version 2 of the Dietary Questionnaire for Epidemiological Studies [DQESv2]) including 13 fruit and 25 vegetable items. The five-item VFQ asked about intake of salad vegetables, cooked vegetables, white potatoes, legumes, and vegetable juice. The screeners were compared with the reference (DQESv2 FFQ) for sensitivity, specificity, and positive and negative predictive powers (PPV, NPV) to detect intakes of two or more servings of fruit and three or more servings of vegetables. Relative validity was examined using Bland-Altman statistics. The fruit SQ showed a PPV of 56% and an NPV of 83%. The PPV for the vegetable SQ was 30% and the NPV was 89%. For the five-item VFQ, the PPV was 39% and the NPV was 85%. Bland-Altman plots and linear regression equations showed that although the screener showed good agreement for fruit (unstandardized b1 coefficient = 0.04) for vegetable intake the difference between methods increased at higher intake levels (unstandardized b1 coefficients = -0.3 for the SQ, b1 = -0.6 for five-item VFQ). The fruit SQ and the five-item VFQ are suitable replacements for longer FFQs to detect inadequate intake and assess population mean but not individual intakes. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Enhanced luminescence of MEH-PPV through the reduction of chain aggregations by blending 4-cyano-4′-N-heptylbiphenyl

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Kuei-Ting [Institute of Organic and Polymeric Materials, National Taipei University of Technology, No.1, Section 3, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan (R.O.C.) (China); Department of Chemical Engineering, Army Academy, No.750, Longdong Rd., Chung-Li 320, Taiwan (R.O.C.) (China); Chang, Shu-Mei; Li, Guo-Yuan [Institute of Organic and Polymeric Materials, National Taipei University of Technology, No.1, Section 3, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan (R.O.C.) (China); Liu, Wei-Ren, E-mail: WRLiu1203@gmail.com [Department of Chemical Engineering, R and D Center for Membrane Center, Chung Yuan Christian University, Chung Li, Taiwan (China)

    2015-02-15

    In this study, we report the electroluminescence and photoluminescence of poly[2-methoxy-5-(2-ethylhexyloxy)-p-phenylene vinylene] (MEH-PPV) and 4-cyano-4′-N-heptylbiphenyl (7CB) blends in the ratios of 0–90 wt% by drop-coating processes. The corresponding characterization of polarized optical microscope, electroluminescence, photoluminescence and atomic force microscope of different blending ratios of MEH-PPV/7CB are systematically carried out in this study. The optimal composition of 6/4 ratio in MEH-PPV/7CB exhibit the highest luminescence, which is almost ten times than that of pure MEH-PPV due to the fact that 7CB could be a barrier to avoid the aggression of MEH-PPV. The novel blending system demonstrate a potential approach for synthesizing the MEH-PPV/7CB composite film for electroluminescent device applications. - Highlights: • We propose a novel blending system of MEH-PPV/7CB system. • Controlling the alignment of polymer. • Avoid the aggression of MEH-PPV. • The luminescence intensity of blend film can be enhanced by 10 times. • A potential approach for electroluminescent device applications.

  5. Validation of Systemic Lupus Erythematosus Diagnosis as the Primary Cause of Renal Failure in the US Renal Data System.

    Science.gov (United States)

    Broder, Anna; Mowrey, Wenzhu B; Izmirly, Peter; Costenbader, Karen H

    2017-04-01

    Using American College of Rheumatology (ACR) and Systemic Lupus International Collaborating Clinics (SLICC) criteria for systemic lupus erythematosus (SLE) classification as gold standards, we determined sensitivity, specificity, positive and negative predictive values (PPV and NPV) of having SLE denoted as the primary cause of end-stage renal disease (ESRD) in the US Renal Data System (USRDS). ESRD patients were identified by International Classification of Diseases, Ninth Revision codes in electronic medical records of 1 large tertiary care center, Montefiore Hospital, from 2006 to 2012. Clinical data were extracted and reviewed to establish SLE diagnosis. Data were linked by social security number, name, and date of birth to the USRDS, where primary causes of ESRD were ascertained. Of 7,396 ESRD patients at Montefiore, 97 met ACR/SLICC SLE criteria, and 86 had SLE by record only. Among the 97 SLE patients, the attributed causes of ESRD in the USRDS were 77 SLE and 12 with other causes (unspecified glomerulonephritis, hypertension, scleroderma), and 8 missing. Sensitivity, specificity, PPV, and NPV for SLE in the USRDS were 79%, 99.9%, 93%, and 99.7%, respectively. Of the 60 patients with biopsy-proven lupus nephritis, 44 (73%) had SLE as primary ESRD cause in the USRDS. Attribution of the primary ESRD causes among SLE patients with ACR/SLICC criteria differed by race, ethnicity, and transplant status. The diagnosis of SLE as the primary cause of ESRD in the USRDS has good sensitivity, and excellent specificity, PPV, and NPV. Nationwide access to medical records and biopsy reports may significantly improve sensitivity of SLE diagnosis. © 2016, American College of Rheumatology.

  6. Metaanalysis of Diagnostic Performance of Computed Coronary Tomography Angiography, Computed Tomography Perfusion and Computed Tomography-Fractional Flow Reserve in Functional Myocardial Ischemia Assessment versus Invasive Fractional Flow Reserve

    Science.gov (United States)

    Gonzalez, Jorge A.; Lipinski, Michael J.; Flors, Lucia F.; Shaw, Peter; Kramer, Christopher M.; Salerno, Michael

    2015-01-01

    We sought to compare the diagnostic performance of computed coronary tomography angiography (CCTA), computed tomography perfusion (CTP) and computed tomography fractional flow reserve (CT-FFR) for assessing the functional significance of coronary stenosis as defined by invasive fractional flow reserve (FFR), in patients with known or suspected coronary artery disease. CCTA has proven clinically useful for excluding obstructive CAD due to its high sensitivity and negative predictive value (NPV), however the ability of CTA to identify functionally significant CAD has remained challenging. We searched PubMed/Medline for studies evaluating CCTA, CTP or CT-FFR for the non-invasive detection of obstructive CAD as compared to catheter-derived FFR as the reference standard. Pooled sensitivity, specificity, PPV, NPV, likelihood ratios (LR), odds ratio (OR) of all diagnostic tests were assessed. Eighteen studies involving a total of 1535 patients were included. CTA demonstrated a pooled sensitivity of 0.92, specificity 0.43, PPV of 0.56 and NPV of 0.87 on a per-patient level. CT-FFR and CTP increased the specificity to 0.72 and 0.77 respectively (P=0.004 and P=0.0009)) resulting in higher point estimates for PPV 0.70 and 0.83 respectively. There was no improvement in the sensitivity. The CTP protocol involved more radiation (3.5 mSv CCTA VS 9.6 mSv CTP) and a higher volume of iodinated contrast (145 mL). In conclusion, CTP and CT-FFR improve the specificity of CCTA for detecting functionally significant stenosis as defined by invasive FFR on a per-patient level; both techniques could advance the ability to non-invasively detect the functional significance of coronary lesions. PMID:26347004

  7. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fiaschetti, V., E-mail: fiaschettivaleria@tin.it [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy); Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G. [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy)

    2012-11-15

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  8. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    International Nuclear Information System (INIS)

    Fiaschetti, V.; Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G.

    2012-01-01

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  9. The value of FDG-PET in diagnosing peritoneal seeding of colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Eun; Moon, Sun Mi; Cheon, Gi Jeong; Choi, Chang Woon; Hwang, Dae Yong; Lim, Sang Moo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2004-07-01

    Peritoneal seeding of colon cancer cells is a common cause of morbidity and eventual mortality with recurrent disease. This study evaluated the role of F -18 FDG PET in detecting peritoneal seeding in colorectal carcinoma (CRC and to identify characteristic patterns of abdominal F-18 FDG uptake. We reviewed the FDG PET and CT images and clinical charts of 49 patients with peritoneal seeding and 22 cancer patients without peritoneal seeding. We also assessed FDG PET scans from 20 healthy volunteers as a baseline study. The maximum standardised uptake values (SUVmax) over peritoneal lesions in cancer patients and over the area of most intense intestinal uptake in healthy volunteers and cancer patients without peritoneal carcinomatosis were measured. The result were correlated with either biopsy or ascitic aspirate. The characteristics of FDG uptake were evaluated: overall pattern (focal or diffuse), heterogeneity (yes or none), intensity (low, or equal, faint to moderate, intense). The sensitivity and positive predictive value (PPV) of FDG PET were superior to CT for the detection of peritoneal lesions (sensitivity: 71.4% vs 57.1%, specificity: 72.7% vs 54.5%: PPV: 85.4% vs 73.7%, NPV: 53.3 % vs 36.4% ). The FDG uptake in patients with peritoneal carcinomatosis was divided into nodular(14), diffuse (23) and mixed pattern (12). An SUVmax threshold of 5.2 produced a diagnostic accuracy of FDG PET of 78%. The additional information provided by FDG PET allowed a more accurate diagnosis in 12 patients (24 %), and led to alteration of the therapeutic strategy in 6 (12.2%) of the enrolled patients (n=49) with peritoneal seeding. FDG-PET was more sensitive than CT for the detection of peritoneal seeding in CRC, and altered patient management. Thus, the application of PET may be beneficial to the management of peritoneal seeding in patient with CRC.

  10. The value of FDG-PET in diagnosing peritoneal seeding of colorectal cancer

    International Nuclear Information System (INIS)

    Kim, Sung Eun; Moon, Sun Mi; Cheon, Gi Jeong; Choi, Chang Woon; Hwang, Dae Yong; Lim, Sang Moo

    2004-01-01

    Peritoneal seeding of colon cancer cells is a common cause of morbidity and eventual mortality with recurrent disease. This study evaluated the role of F -18 FDG PET in detecting peritoneal seeding in colorectal carcinoma (CRC and to identify characteristic patterns of abdominal F-18 FDG uptake. We reviewed the FDG PET and CT images and clinical charts of 49 patients with peritoneal seeding and 22 cancer patients without peritoneal seeding. We also assessed FDG PET scans from 20 healthy volunteers as a baseline study. The maximum standardised uptake values (SUVmax) over peritoneal lesions in cancer patients and over the area of most intense intestinal uptake in healthy volunteers and cancer patients without peritoneal carcinomatosis were measured. The result were correlated with either biopsy or ascitic aspirate. The characteristics of FDG uptake were evaluated: overall pattern (focal or diffuse), heterogeneity (yes or none), intensity (low, or equal, faint to moderate, intense). The sensitivity and positive predictive value (PPV) of FDG PET were superior to CT for the detection of peritoneal lesions (sensitivity: 71.4% vs 57.1%, specificity: 72.7% vs 54.5%: PPV: 85.4% vs 73.7%, NPV: 53.3 % vs 36.4% ). The FDG uptake in patients with peritoneal carcinomatosis was divided into nodular(14), diffuse (23) and mixed pattern (12). An SUVmax threshold of 5.2 produced a diagnostic accuracy of FDG PET of 78%. The additional information provided by FDG PET allowed a more accurate diagnosis in 12 patients (24 %), and led to alteration of the therapeutic strategy in 6 (12.2%) of the enrolled patients (n=49) with peritoneal seeding. FDG-PET was more sensitive than CT for the detection of peritoneal seeding in CRC, and altered patient management. Thus, the application of PET may be beneficial to the management of peritoneal seeding in patient with CRC

  11. Annual surveillance by CA125 and transvaginal ultrasound for ovarian cancer in both high-risk and population risk women is ineffective

    DEFF Research Database (Denmark)

    Woodward, E R; Sleightholme, H V; Considine, A M

    2007-01-01

    OBJECTIVE: To assess the efficacy of annual CA125 and transvaginal ultrasound (TVU) scan as surveillance for ovarian cancer. DESIGN: Retrospective audit. SETTING: NHS Trust. POPULATION: Three hundred and forty-one asymptomatic women enrolled for ovarian cancer screening: 179 were in a high...... and local cancer registry data. MAIN OUTCOME MEASURES: Ovarian cancers occurring in study population. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TVU, and CA125 as a screening tool for ovarian cancer. RESULTS: Four ovarian cancers and one endometrial...... cancer occurred. One ovarian cancer was detected at surveillance, three occurred in women who presented symptomatically between screenings. Thirty women underwent exploratory surgery because of abnormal findings at surveillance. Two women had cancer (PPV = 6.7%); one had ovarian cancer and the other...

  12. Analisis Strategi Bisnis NPV, IRR, PI dan DPB pada Golden Restaurant Jakarta

    Directory of Open Access Journals (Sweden)

    Kriswanto Kriswanto

    2011-05-01

    Full Text Available Golden Restaurant is located in Senayan, South Jakarta. Because of intense competition and a lack of good economic growth in Indonesia, the restaurant sales dropped sharply and having some problems in operation. The measures is to do effective business strategies to improve business performance by conducting research, create a budget to analyze and predict the financial performance, and formulate an effective working capital structure. Formulation of the problem discussed is NPV and IRR of restaurant sales for the feasibility of an investment, securities of the PI and IBA restaurant on the return on investment and analysis NPV, IRR, PI and IBA on strategy formulation restaurant. From the analysis of simple direct study expected an increase in sales to 90% per year and provide a significant positive NPV and IRR of almost 20% which is higher than the original expectation of 15% and reach breakeven point within 4 to 7 years. From the results of this analysis also shows the business is sensitive to increased sales, operating expenses and cost of sales. In addition to inflation and economic conditions affect the performance of sensitive business. 

  13. The relationship between the violet pigment PP-V production and intracellular ammonium level in Penicillium purpurogenum.

    Science.gov (United States)

    Kojima, Ryo; Arai, Teppei; Matsufuji, Hiroshi; Kasumi, Takafumi; Watanabe, Taisuke; Ogihara, Jun

    2016-12-01

    Penicillium purpurogenum is the fungus that produces an azaphilone pigment. However, details about the pigment biosynthesis pathway are unknown. The violet pigment PP-V is the one of the main pigments biosynthesized by this fungus. This pigment contains an amino group in a pyran ring as its core structure. We focused on this pigment and examined the relationship between intracellular ammonium concentration and pigment production using glutamine as a nitrogen source. The intracellular ammonium level decreased about 1.5-fold in conditions favoring PP-V production. Moreover, P. purpurogenum was transferred to medium in which it commonly produces the related pigment PP-O after cultivating it in the presence or absence of glutamine to investigate whether this fungus biosynthesizes PP-V using surplus ammonium in cells. Only mycelia cultured in medium containing 10 mM glutamine produced the violet pigment, and simultaneously intracellular ammonium levels decreased under this condition. From comparisons of the amount of PP-V that was secreted with quantity of surplus intracellular ammonium, it is suggested that P. purpurogenum maintains ammonium homeostasis by excreting waste ammonium as PP-V.

  14. Improvement in the detection of locoregional recurrence in head and neck malignancies: F-18 fluorodeoxyglucose-positron emission tomography/computed tomography compared to high-resolution contrast-enhanced computed tomography and endoscopic examination.

    Science.gov (United States)

    Rangaswamy, Balasubramanya; Fardanesh, M Reza; Genden, Eric M; Park, Eunice E; Fatterpekar, Girish; Patel, Zara; Kim, Jongho; Som, Peter M; Kostakoglu, Lale

    2013-11-01

    To compare the diagnostic efficacy of positron emission tomography (PET) with F-18 fluorodeoxyglucose (FDG-PET)/computed tomography (CT) to that of contrast-enhanced high-resolution CT (HRCT) and assess the value of a combinatorial approach in detection of recurrent squamous cell cancer of the head and neck (HNC) and to assess the efficacy of FDG-PET/CT with and without HRCT in comparison to standard-of-care follow-up--physical examination (PE) and endoscopy (E)--in determination of locally recurrent HNC. Retrospective study. A total of 103 patients with HNC underwent FDG-PET/CT and neck HRCT. There were two groups of patients: Group A had an FDG-PET study acquired with low-dose CT, and group B had an FDG-PET study acquired with HRCT. The PET data obtained with or without HRCT were compared on a lesion and patient basis with the results of the PE/E. On a lesion basis, both groups combined had higher sensitivity and negative predictive value (NPV) than the HRCT. Specificity and positive predictive value (PPV) for group B were higher than for group A. On a patient basis, both groups combined had a higher sensitivity and NPV than PE/E, respectively, although specificity of PE/E was higher than that of either group. PET data obtained with either protocol directly influenced treatment. HRCT increases the specificity and PPV of PET/CT when acquired simultaneously with PET. FDG-PET/CT acquired with either LDCT or HRCT has higher accuracy than HRCT alone and increases the sensitivity and NPV of PE/E. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Ultrafast Charge Photogeneration in MEH-PPV Charge-Transfer Complexes

    NARCIS (Netherlands)

    Bakulin, Artem A.; Paraschuk, Dmitry Yu; Pshenichnikov, Maxim S.; van Loosdrecht, Paul H. M.; Corkum, P; DeSilvestri, S; Nelson, KA; Riedle, E; Schoenlein, RW

    2009-01-01

    Visible-pump - IR-probe spectroscopy is used to study the ultrafast charge dynamics in MEH-PPV based charge-transfer complexes and donor-acceptor blends. Transient anisotropy of the polymer polaron band provides invaluable insights into excitation localisation and charge-transfer pathways.

  16. Predicting protein-binding RNA nucleotides with consideration of binding partners.

    Science.gov (United States)

    Tuvshinjargal, Narankhuu; Lee, Wook; Park, Byungkyu; Han, Kyungsook

    2015-06-01

    In recent years several computational methods have been developed to predict RNA-binding sites in protein. Most of these methods do not consider interacting partners of a protein, so they predict the same RNA-binding sites for a given protein sequence even if the protein binds to different RNAs. Unlike the problem of predicting RNA-binding sites in protein, the problem of predicting protein-binding sites in RNA has received little attention mainly because it is much more difficult and shows a lower accuracy on average. In our previous study, we developed a method that predicts protein-binding nucleotides from an RNA sequence. In an effort to improve the prediction accuracy and usefulness of the previous method, we developed a new method that uses both RNA and protein sequence data. In this study, we identified effective features of RNA and protein molecules and developed a new support vector machine (SVM) model to predict protein-binding nucleotides from RNA and protein sequence data. The new model that used both protein and RNA sequence data achieved a sensitivity of 86.5%, a specificity of 86.2%, a positive predictive value (PPV) of 72.6%, a negative predictive value (NPV) of 93.8% and Matthews correlation coefficient (MCC) of 0.69 in a 10-fold cross validation; it achieved a sensitivity of 58.8%, a specificity of 87.4%, a PPV of 65.1%, a NPV of 84.2% and MCC of 0.48 in independent testing. For comparative purpose, we built another prediction model that used RNA sequence data alone and ran it on the same dataset. In a 10 fold-cross validation it achieved a sensitivity of 85.7%, a specificity of 80.5%, a PPV of 67.7%, a NPV of 92.2% and MCC of 0.63; in independent testing it achieved a sensitivity of 67.7%, a specificity of 78.8%, a PPV of 57.6%, a NPV of 85.2% and MCC of 0.45. In both cross-validations and independent testing, the new model that used both RNA and protein sequences showed a better performance than the model that used RNA sequence data alone in

  17. Validation of a second-generation multivariate index assay for malignancy risk of adnexal masses.

    Science.gov (United States)

    Coleman, Robert L; Herzog, Thomas J; Chan, Daniel W; Munroe, Donald G; Pappas, Todd C; Smith, Alan; Zhang, Zhen; Wolf, Judith

    2016-07-01

    Women with adnexal mass suspected of ovarian malignancy are likely to benefit from consultation with a gynecologic oncologist, but imaging and biomarker tools to ensure this referral show low sensitivity and may miss cancer at critical stages. The multivariate index assay (MIA) was designed to improve the detection of ovarian cancer among women undergoing surgery for a pelvic mass. To improve the prediction of benign masses, we undertook the redesign and validation of a second-generation MIA (MIA2G). MIA2G was developed using banked serum samples from a previously published prospective, multisite registry of patients who underwent surgery to remove an adnexal mass. Clinical validity was then established using banked serum samples from the OVA500 trial, a second prospective cohort of adnexal surgery patients. Based on the final pathology results of the OVA500 trial, this intended-use population for MIA2G testing was high risk, with an observed cancer prevalence of 18.7% (92/493). Coded samples were assayed for MIA2G biomarkers by an external clinical laboratory. Then MIA2G results were calculated and submitted to a clinical statistics contract organization for decoding and comparison to MIA results for each subject. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated, among other measures, and stratified by menopausal status, stage, and histologic subtype. Three MIA markers (cancer antigen 125, transferrin, and apolipoprotein A-1) and 2 new biomarkers (follicle-stimulating hormone and human epididymis protein 4) were included in MIA2G. A single cut-off separated high and low risk of malignancy regardless of patient menopausal status, eliminating potential for confusion or error. MIA2G specificity (69%, 277/401 [n/N]; 95% confidence interval [CI], 64.4-73.4%) and PPV (40%, 84/208; 95% CI, 33.9-47.2%) were significantly improved over MIA (specificity, 54%, 215/401; 95% CI, 48.7-58.4%, and PPV, 31%, 85/271; 95

  18. Spanish validation of the adult Attention Deficit/Hyperactivity Disorder Rating Scale (ADHD-RS): relevance of clinical subtypes.

    Science.gov (United States)

    Richarte, Vanesa; Corrales, Montserrat; Pozuelo, Marian; Serra-Pla, Juanfran; Ibáñez, Pol; Calvo, Eva; Corominas, Margarida; Bosch, Rosa; Casas, Miquel; Ramos-Quiroga, Josep Antoni

    Adult attention deficit hyperactivity disorder (ADHD) has a prevalence between 2.5% and 4% of the general adult population. Over the past few decades, self-report measures have been developed for the current evaluation of adult ADHD. The ADHD-RS is a 18-items scale self-report version for assessing symptoms for ADHD DSM-IV. A validation of Spanish version of the ADHD-RS was performed. The sample consisted of 304 adult with ADHD and 94 controls. A case control study was carried out (adult ADHD vs. non ADHD). The diagnosis of ADHD was evaluated with the Structured Clinical Interview for DSM-IV (SCID-I) and the Conners Adult ADHD Diagnostic Interview for DSM-IV (CAADID-II). To determinate the internal validity of the two dimensions structure of ADHD-RS an exploratory factor analysis was performed. The α-coefficients were taken as a measure of the internal consistency of the dimensions considered. A logistic regression study was carried out to evaluate the model in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV). Average age was 33.29 (SD=10.50) and 66% of subjects were men (there were no significant differences between the two groups). Factor analysis was done with a principal component analysis followed by a normalized varimax rotation. The Kaiser-Meyer-Olkin measure of sampling adequacy tests was .868 (remarkable) and the Bartlett's test of sphericity was 2 (153)=1,835.76, P<.0005, indicating the appropriateness of the factor analysis. This two-factor model accounted for 37.81% of the explained variance. The α-coefficient of the two factors was .84 and .82. The original strategy proposed 24 point for cut-off: sensitivity (81.9%), specificity (74.7%), PPV (50.0%), NPV (93.0%), kappa coefficient .78 and area under the curve (AUC) .89. The new score strategy proposed by our group suggests different cut-off for different clinical presentations. The 24 point is the best cut-off for ADHD combined presentation

  19. [Hospitalizations for ambulatory care-sensitive conditions: validation study at a Hospital Information System (SIH) in the Federal District, Brazil, in 2012].

    Science.gov (United States)

    Cavalcante, Danyelle Monteiro; de Oliveira, Maria Regina Fernandes; Rehem, Tânia Cristina Morais Santa Bárbara

    2016-03-01

    This study analyzes hospitalizations due to ambulatory care-sensitive conditions with a focus on infectious and parasitic diseases (IPDs) and validates the Hospital Information System, Brazilian Unified National Health System (SIH/SUS) for recording hospitalizations due to ambulatory care-sensitive conditions in a hospital in the Federal District, Brazil, in 2012. The study estimates the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the SIH for recording hospitalizations due to ambulatory care-sensitive conditions, with the patient's medical file as the gold standard. There were 1,604 hospitalizations for hospitalizations due to ambulatory care-sensitive conditions (19.6%, 95%CI: 18.7-20.5), and the leading IPDs were renal and urinary tract infection, infection of the skin and subcutaneous tissue, and infectious gastroenteritis. IPDs were the leading cause of hospitalization in the 20 to 29-year age bracket and caused 28 deaths. Sensitivity was 70.1% (95%CI: 60.5-79.7), specificity 88.4% (95%CI: 85.6-91.2), PPV = 51.7% (95%CI: 42.7-60.7), and NPV = 94.3% (95%CI: 92.2-96.4). The findings for admissions due to ACSCs in this hospital were similar to those of other studies, featuring admissions for IPDs. The SIH/SUS database was more specific than sensitive.

  20. Detection of Trichomonas Vaginalis Infection in Male Non-gonococcal Urethritis Patients by InPouch TV Culture and Polymerase Chain Reaction

    Institute of Scientific and Technical Information of China (English)

    YAO Zhiyuan(姚志远); ZHENG Heyi(郑和义); CAO Jingjiang(曹经江)

    2002-01-01

    Objective: To study the prevalence of Trichomonas vaginalis(TV) infection in Chinese male patients with nongonococcalurethritis (NGU), to evaluate the sensitivity and specificity ofurine-based and urethral swab polymerase chain reaction(PCR) detection, to set up a method for non-invasive detectionof male TV infection. Method: One hundred and five male NGU patients wereselected from a Beijing STD clinic. Two urethral swabs wereobtained from each patient, one for the InPouch TV culturesystem and the other for PCR. In addition, one first void urinespecimen was collected for PCR detection. Culture wasconsidered the "gold standard". The sensitivity, specificity,positive predictive value (PPV) and negative predictive value(NPV) of the two PCR detections were compared to cultureresults. Results: The prevalence of urine-based PCR and urethralswab PCR detection was 3.81% (4/105) and 4.76% (5/105)respectively. Compared to culture, the sensitivity, specificity,PPV and NPV were 80%, 100%, 100% and 99% for urine-based PCR and 80%, 99%, 80% and 99% for urethral swabPCR.Conclusion: TV is one of the etiological agents in male NGU,with a 4.76% prevalence of infection in our study. The urine-based PCR detection has higher sensitivity and specificity andprovides a noninvasive method more feasible in practice.

  1. Peristalsis gap sign at cine magnetic resonance imaging for diagnosing strangulated small bowel obstruction. Feasibility study

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, T.C.; Haradome, Hiroki

    2011-01-01

    The aim of this study was to determine the feasibility of cine magnetic resonance imaging (MRI) for diagnosing strangulated small bowel obstruction (SBO). This study included 38 patients with clinically confirmed SBO who had undergone cine MRI. Cine MRI scans were evaluated regarding the presence of the 'peristalsis gap sign' (referring to an akinetic or severely hypokinetic closed loop), indicating strangulation. Computed tomography (CT) was performed in 34 of 38 patients with (n=25) or without (n=9) contrast enhancement. CT images were evaluated using a combination of criteria (presence of hyperattenuation, poor contrast enhancement, mesenteric edema, wall thickening, massive ascites) indicating strangulation. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of cine MRI and CT for the diagnosis of strangulation were calculated and compared using surgical findings and the clinical course as the reference standard. Sensitivity, specificity, PPV, and NPV of cine MRI were 100%, 92.9%, 83.3%, and 100%, respectively; and those of CT (of which 26.5% was performed without contrast enhancement) were 66.7%, 92.0%, 75.0%, and 88.5%, respectively. There was no significant difference in diagnostic accuracy between the two methods (P=0.375). Cine MRI is a feasible and promising technique for diagnosing strangulation. (author)

  2. Bone scan and joint scan of hands and feet in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Carpentier, N.; Verbeke, S.; Perdrisot, R.; Grilo, R.M.; Quenesson, E.; Bonnet, C.; Vergne, P.; Treves, R.; Bertin, P.; Boutros-Toni, F.

    2000-01-01

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate 99m Tc intravenous injection. Patients were scanned 5 minutes (tissual time, T t ) and 3 hours 1/4 (bone time, T 0 ) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of 99m Tc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T 0 . The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)

  3. [Photovoltaic character of organic EL devices MEH-PPV/Alq3].

    Science.gov (United States)

    Lin, Peng; Liang, Chun-Jun; Deng, Zhen-Bo; Xiong, De-Ping; Wang, Li; Zhang, Zhi-Feng; Zhang, Xi-Qing

    2005-01-01

    An organic photovoltaic(PV) cell, ITO/MEH-PPV/Alq3/LiF/Al, was fabricated. The MEH-PPV and Alq3 are the electron-acceptor and donor in the cell, respectively. The respond region matchs the adsorption of Alq3 film. Under UV light with 0.5 mW x cm(-2), the cell shows a short-circuit current of 2.4 microA x cm(-2), open-circuit voltage of 2.6 V, a fill factor of 0.71, and a power conversion efficiency of 0.9%. It was found that the PV cell indicates electroluminescence (EL) performance and could emit orange light at DC voltage. The maximum luminance is about 1 000 cd x cm(-2) at 15 V.

  4. Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yang; Ma, Yue; Wang, Yuke; Yu, Mei; Guo, Qiyong [Shengjing Hospital of China Medical University, Department of Radiology, Shenyang (China); Fan, Weipeng [Central Hospital of Anshan, Department of Radiology, Anshan (China); Vembar, Mani [CT Clinical Science Philips Healthcare, Cleveland, OH (United States)

    2014-01-15

    To evaluate the accuracy of low-dose coronary CTA with iterative reconstruction (IR) in the diagnosis of coronary artery disease (CAD) in patients with suspected CAD. Ninety-six patients with suspected CAD underwent low-dose prospective electrocardiogram-gated coronary CTA, with images reconstructed using IR. Image quality (IQ) of coronary segments were graded on a 4-point scale (4, excellent; 1, non-diagnostic). With invasive coronary angiography (ICA) considered the ''gold standard'', the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of coronary CTA were calculated on segment-, vessel- and patient-based levels. The patient data were divided into two groups (Agatston scores of ≥ 400 and <400). The differences in diagnostic performance between the two groups were tested. Diagnostic image quality was found in 98.1 % (1,232/1,256) of segments. The sensitivity, specificity, PPV, NPV and accuracy were 90.8 %, 95.3 %, 81.8 %, 97.8 % and 94.3 % (segment-based) and 97.2 %, 83.3 %, 94.6 %, 90.9 % and 93.8 % (patient-based). Significant differences between the two groups were seen in specificity, PPV and accuracy (92.1 % vs. 97.9 %, 76.0 % vs. 86.7 %, 91.7 % vs. 96.6 %, P < 0.05; segment-based). The average effective dose was 1.30 ± 0.15 mSv. Low-dose prospective coronary CTA with IR can acquire satisfactory image quality and show high diagnostic accuracy in patients with suspected CAD; however, blooming continues to pose a challenge in severely calcified segments. (orig.)

  5. Radiologic identification of disaster victims: A simple and reliable method using CT of the paranasal sinuses

    International Nuclear Information System (INIS)

    Ruder, Thomas D.; Kraehenbuehl, Markus; Gotsmy, Walther F.; Mathier, Sandra; Ebert, Lars C.; Thali, Michael J.; Hatch, Gary M.

    2012-01-01

    Objective: To assess the reliability of radiologic identification using visual comparison of ante and post mortem paranasal sinus computed tomography (CT). Subjects and methods: The study was approved by the responsible justice department and university ethics committee. Four blinded readers with varying radiological experience separately compared 100 post mortem to 25 ante mortem head CTs with the goal to identify as many matching pairs as possible (out of 23 possible matches). Sensitivity, specificity, positive and negative predictive values were calculated for all readers. The chi-square test was applied to establish if there was significant difference in sensitivity between radiologists and non-radiologists. Results: For all readers, sensitivity was 83.7%, specificity was 100.0%, negative predictive value (NPV) was 95.4%, positive predictive value (PPV) was 100.0%, and accuracy was 96.3%. For radiologists, sensitivity was 97.8%, NPV was 99.4%, and accuracy was 99.5%. For non-radiologists, average sensitivity was 69.6%, negative predictive value (NPV) was 91.7%, and accuracy was 93.0%. Radiologists achieved a significantly higher sensitivity (p < 0.01) than non-radiologists. Conclusions: Visual comparison of ante mortem and post mortem CT of the head is a robust and reliable method for identifying unknown decedents, particularly in regard to positive matches. The sensitivity and NPV of the method depend on the reader's experience.

  6. The role of urinary fractionated metanephrines in the diagnosis of phaeochromocytoma

    Directory of Open Access Journals (Sweden)

    Kanakamani Jeyaraman

    2013-01-01

    Full Text Available Background & objectives: Plasma and urinary metanephrines are used as screening tests for the diagnosis of phaeochromocytoma. The recommended cut-off levels are not standardized. This study was conducted to identify a cut-off level for 24 h urinary fractionated metanephrines viz. metanephrine (uMN and normetanephrine (uNMN using enzyme immunoassay for the diagnosis of phaeochromocytoma. Methods: Consecutive patients suspected to have phaeochromocytoma were included in the study. uMN and uNMN in 24 h urinary sample were measured using a commercial ELISA kit. Results: Overall, 72 patients were included over a period of 18 months. Twenty patients had histopathologically confirmed phaeochromocytoma and in 52 patients phaeochromocytoma was ruled out. Using the upper limit of normal stated by the assay manufacturer as the cut-off, uMN >350 μg/day had a low sensitivity and uNMN >600 μg/day had a poor specificity. By increasing the cut-off value of uNMN to twice the upper limit, specificity increased significantly without much loss in sensitivity. Combining uMN and uNMN using a cut-off twice the upper limit improved the diagnostic performance - sensitivity (95%; specificity (92.3%; positive predictive value (PPV - 82.6%; negative predictive value (NPV - 98%. In subsets of patients with a variable pretest probability for phaeochromocytoma, the PPV correlates well with the occurred of these tumors decreased, while the NPV remained at 100 per cent. Interpretation & conclusions: ELISA is a simple and reliable method for measuring uMN and uNMN. The test has a good NPV and can be used as an initial screening test for ruling out phaeochromocytoma. Each hospital will have to define the cut-off value for the assay being used, choosing a proper control population.

  7. Qualidade da avaliação da acuidade visual realizada pelos professores do programa " Olho no olho" da cidade de Marília, SP Assessment of visual acuity evaluation performed by teachers of the "Eye in eye" program in Marília-SP, Brazil

    Directory of Open Access Journals (Sweden)

    Lígia Issa De Fendi

    2008-08-01

    Full Text Available OBJETIVOS: Avaliar a qualidade e o ponto de corte (AV PURPOSE: To assess quality and cut-off point (VA <0.7 of the examinations performed by teachers to detect reduced visual acuity (VA in schoolchildren participants of the project called "Eye in eye " in Marilia-SP, Brazil. METHODS: Visual acuity measurements were performed by trained teachers using Snellen's chart. The children with VA <0.7 in one of the eyes were referred to an ophthalmic examination. The ophthalmic examination was considered gold standard to assess quality and cut-off point of the examinations performed by teachers. VA test was performed in 604 schoolchildren of state public schools (1,208 eyes. Analyses were based on examined eyes. We calculated sensitivity (S, specificity (E, positive predictive value (PPV, negative predictive value (NPV and likelihood rate (LR. We compared the means obtained by the teachers' examinations to means of the ophthalmologist's examinations. ROC curve was produced to evaluate whether VA lower than 0.7 is the best value for referral to an ophthalmic examination. RESULTS: VA means obtained by teachers and ophthalmologic examinations were 0.70 ± 0.16 and 0.88 ± 0.2 respectively. The difference between teachers' and ophthalmologists' examinations was 0.18 (p<0.0001. S, E, PPV, NPV e LR were: 82%, 40%, 27%, 89% and 1.37, respectively. False positive and negative rates were 59.5% and 18%. ROC curve evidenced that visual acuity of 0.7 was the best cut-off point to refer schoolchildren to an ophthalmic exam. CONCLUSIONS: We demonstrated the importance of the teachers' participation in improved schoolchildren ocular health. The examination performed by teachers obtained a satisfactory S with low E, NPV and high values of false positive results. The best cut-off point to refer schoolchildren to an ophthalmic examination was VA of 0.7.

  8. Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements.

    Science.gov (United States)

    Ascenti, Giorgio; Mileto, Achille; Krauss, Bernhard; Gaeta, Michele; Blandino, Alfredo; Scribano, Emanuele; Settineri, Nicola; Mazziotti, Silvio

    2013-08-01

    To compare the diagnostic accuracy of iodine quantification and standard enhancement measurements in distinguishing enhancing from nonenhancing renal masses. The Institutional Review Board approved this retrospective study conducted from data found in institutional patient databases and archives. Seventy-two renal masses were characterised as enhancing or nonenhancing using standard enhancement measurements (in HU) and iodine quantification (in mg/ml). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of standard enhancement measurements and iodine quantification were calculated from χ (2) tests of contingency with histopathology or imaging follow-up as the reference standard. Difference in accuracy was assessed by means of McNemar analysis. Sensitivity, specificity, PPV, NPV and diagnostic accuracy for standard enhancement measurements and iodine quantification were 77.7 %, 100 %, 100 %, 81.8 %, 89 % and 100 %, 94.4 %, 94.7, 100 % and 97 %, respectively. The McNemar analysis showed that the accuracy of iodine quantification was significantly better (P < 0.001) than that of standard enhancement measurements. Compared with standard enhancement measurements, whole-tumour iodine quantification is more accurate in distinguishing enhancing from nonenhancing renal masses. • Enhancement of renal lesions is important when differentiating benign from malignant tumours. • Dual-energy CT offers measurement of iodine uptake rather than mere enhancement values. • Whole-tumour iodine quantification seems more accurate than standard CT enhancement measurements.

  9. Synovialisation of the torn anterior cruciate ligament of the knee: comparison between magnetic resonance and arthroscopy

    International Nuclear Information System (INIS)

    Higueras Guerrero, V.; Torregrosa Andres, A.; Marti-Bonmati, L.; Casillas, C.; Sanfeliu, M.

    1999-01-01

    The aim of this study was to assess the accuracy of MR in the diagnosis of synovialisation of the anterior cruciate ligament (ACL) compared with arthroscopy. One hundred and forty-nine patients were examined with MR imaging and arthroscopy of the knee. The MR sign used to consider a synovialised ACL consisted of hypointense fibrillar tracts, disrupted and wavily, in its expected course. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), comparison of proportions (McNemar test) and Kappa values for agreement between MR imaging and arthroscopy were calculated. Of the 133 (89.3 %) ligaments without synovialisation at arthroscopy, 130 accorded with the MR results. Of the 16 (10.7 %) synovialised ligaments, 13 accorded with the MR results. Three false-positive and three false-negative MR diagnoses were identified. The agreement between both techniques was excellent (Kappa = 0.79; p = 0.000), without differences (McNemar test; p = 1). Sensitivity was 0.81, specificity 0.98, PPV 0.98 and NPV 0.81. Magnetic resonance imaging is highly reliability for synovialisation diagnosis. The imaging sign used to diagnose synovialised ACL (hypointense comma-like tracts in its expected course) is reliable. As this reparative process can simulate an intact ligament, knowledge of this sign is important in diagnosing synovialisation of ACL tears so as not to confuse it with normal ACL. (orig.)

  10. Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard: a retrospective study.

    Science.gov (United States)

    Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz

    2018-02-26

    Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.

  11. Validation of asthma recording in electronic health records: a systematic review

    Directory of Open Access Journals (Sweden)

    Nissen F

    2017-12-01

    Full Text Available Francis Nissen,1 Jennifer K Quint,2 Samantha Wilkinson,1 Hana Mullerova,3 Liam Smeeth,1 Ian J Douglas1 1Department of Non-Communicable Disease Epidemiology, London School of Hygiene and Tropical Medicine, London, UK; 2National Heart and Lung Institute, Imperial College, London, UK; 3RWD & Epidemiology, GSK R&D, Uxbridge, UK Objective: To describe the methods used to validate asthma diagnoses in electronic health records and summarize the results of the validation studies. Background: Electronic health records are increasingly being used for research on asthma to inform health services and health policy. Validation of the recording of asthma diagnoses in electronic health records is essential to use these databases for credible epidemiological asthma research.Methods: We searched EMBASE and MEDLINE databases for studies that validated asthma diagnoses detected in electronic health records up to October 2016. Two reviewers independently assessed the full text against the predetermined inclusion criteria. Key data including author, year, data source, case definitions, reference standard, and validation statistics (including sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV] were summarized in two tables.Results: Thirteen studies met the inclusion criteria. Most studies demonstrated a high validity using at least one case definition (PPV >80%. Ten studies used a manual validation as the reference standard; each had at least one case definition with a PPV of at least 63%, up to 100%. We also found two studies using a second independent database to validate asthma diagnoses. The PPVs of the best performing case definitions ranged from 46% to 58%. We found one study which used a questionnaire as the reference standard to validate a database case definition; the PPV of the case definition algorithm in this study was 89%. Conclusion: Attaining high PPVs (>80% is possible using each of the discussed validation

  12. Whipple Resection: Concordance Between Frozen Section And Permanent Section Diagnosis Of Surgical Margins.

    Science.gov (United States)

    Bilal, Muhammad; Tariq, Hina; Mamoon, Nadira

    2018-01-01

    Margin assessment is done in Whipple procedures which are usually performed to resect tumours of head of pancreas and ampullary/periampullary region. Aims and objective of the study are to determine the concordance between frozen sections (FS) and permanent sections (PS) of surgical margins in Whipple resections. It is a retrospective study, from January 2008 to January 2015 (07 years). It includes the specimen with malignancy in final report and for which FS of pancreatic and/or CBD margin(s) were requested. Data was retrieved from Laboratory information system (LIS) database. Of the 41 bile duct margins in cases of ampullary tumours, 03 were positive on FS as well as PS, 35 were negative on FS as well as on PS. Results showed 100% sensitivity, 92.1% specificity, 50% PPV and 100% NPV. Results of 36 pancreatic margins in cases of ampullary showed 100% sensitivity, 97.1% specificity, 50% PPV and 100% NPV. In pancreatic carcinoma cases, none of CBD margins were reported as positive on FS, 02 margins reported as negative were found positive on PS, while 17 were negative on FS as well as PS. Results showed 100% specificity and 89.5% NPV. Of the 27 pancreatic margins tested in pancreatic tumours 100% sensitivity, 94.1% specificity, 88.9% PPV and 100% NPV was found. Factors such as absent prior tissue diagnosis and/or inflammatory processes make margin diagnosis difficult. However, a high concordance was observed between our FS and PS diagnosis.

  13. Blue shift in the luminescence spectra of MEH-PPV films containing ZnO nanoparticles

    International Nuclear Information System (INIS)

    Ton-That, Cuong; Phillips, Matthew R.; Nguyen, Thien-Phap

    2008-01-01

    Luminescence properties of nanocomposites consisting of ZnO nanoparticles in a conjugated polymer, poly [2-methoxy-5-(2'-ethyl hexyloxy)-phenylene vinylene] (MEH-PPV), were investigated. Photoluminescence measurements reveal a blue shift in the emission spectrum of MEH-PPV upon incorporation of ZnO nanoparticles into the polymer film while the emission is increasingly quenched with increasing ZnO concentration. In contrast, the structure of the polymer and its conjugation length are not affected by the presence of ZnO nanoparticles (up to 16 wt% ZnO) as revealed by Raman spectroscopy. The blue shift and photoluminescence quenching are explained by the separation of photogenerated electron-hole pairs at the MEH-PPV/ZnO interface and the charging of the nanoparticles

  14. Surface structure, optoelectronic properties and charge transport in ZnO nanocrystal/MDMO-PPV multilayer films.

    Science.gov (United States)

    Lian, Qing; Chen, Mu; Mokhtar, Muhamad Z; Wu, Shanglin; Zhu, Mingning; Whittaker, Eric; O'Brien, Paul; Saunders, Brian R

    2018-05-07

    Blends of semiconducting nanocrystals and conjugated polymers continue to attract major research interest because of their potential applications in optoelectronic devices, such as solar cells, photodetectors and light-emitting diodes. In this study we investigate the surface structure, morphological and optoelectronic properties of multilayer films constructed from ZnO nanocrystals (NCs) and poly[2-methoxy-5-(3',7'-dimethyloctyloxy)-1,4-phenylenevinylene] (MDMO-PPV). The effects of layer number and ZnO concentration (C ZnO ) used on the multilayer film properties are investigated. An optimised solvent blend enabled well-controlled layers to be sequentially spin coated and the construction of multilayer films containing six ZnO NC (Z) and MDMO-PPV (M) layers (denoted as (ZM) 6 ). Contact angle data showed a strong dependence on C ZnO and indicated distinct differences in the coverage of MDMO-PPV by the ZnO NCs. UV-visible spectroscopy showed that the MDMO-PPV absorption increased linearly with the number of layers in the films and demonstrates highly tuneable light absorption. Photoluminescence spectra showed reversible quenching as well as a surprising red-shift of the MDMO-PPV emission peak. Solar cells were constructed to probe vertical photo-generated charge transport. The measurements showed that (ZM) 6 devices prepared using C ZnO = 14.0 mg mL -1 had a remarkably high open circuit voltage of ∼800 mV. The device power conversion efficiency was similar to that of a control bilayer device prepared using a much thicker MDMO-PPV layer. The results of this study provide insight into the structure-optoelectronic property relationships of new semiconducting multilayer films which should also apply to other semiconducting NC/polymer combinations.

  15. Hybrid electroluminescent device based on MEH-PPV and ZnO

    Energy Technology Data Exchange (ETDEWEB)

    Hewidy, Dina; Gadallah, A.-S.; Fattah, G. Abdel

    2017-02-15

    Hybrid organic/inorganic electroluminescent device based on the structure of glass/ITO/PEDOT:PSS/MEH-PPV/ZnO/ZnO submicrorods/Al has been manufactured. Spin coating has been used to deposit both PEDOT:PSS and MEH-PPV. Two-step process has been used to synthesis ZnO submicrorods, namely, spin coating and chemical bath deposition. Changing the dimensions of the ZnO submicrorods in this layer structure has been investigated to improve the performance of the organic/inorganic electroluminescence device. Such layer structure provides electroluminescence with narrow emission bands due to a high gain with this structure. X-ray diffraction patterns and scanning electron microscope images show that ZnO submicrorods have hexagon structure. Current-voltage curve for the structure has been reported. Electroluminescence curves (electroluminescence intensity versus wavelength) at different bias voltages have been presented and these results show narrowing in full width at half maximum in the spectra at high current density compared to photoluminescence excitation. The narrowing in the spectrum has been explained. - Highlights: • Manufacturing of MEH-PPV and ZnO electroluminescent device has been reported. • Spin coating and chemical bath deposition have been used for preparation of ZnO. • SEM images and X-ray diffraction of ZnO have been presented. • Current-voltage curves and electroluminescent measurements have been reported.

  16. Comparison of three assays currently used for diagnosis of legionellosis

    Directory of Open Access Journals (Sweden)

    Maria Chiucini

    2010-12-01

    Full Text Available The laboratory diagnosis of Legionnaires’ disease is extremely complex due to the difficulty of isolating and identifying the etiological agent in a short time and also for the frequent late appearance of antibodies. For this reason it should use not only the cultures but also other diagnostic tests such as urinary antigen and antibody research. Our study evaluated the performance of these methods.We calculated the positive predictive value (PPV and negative predictive value (NPV, sensitivity and specificity of each test.

  17. Chance-constrained programming models for capital budgeting with NPV as fuzzy parameters

    Science.gov (United States)

    Huang, Xiaoxia

    2007-01-01

    In an uncertain economic environment, experts' knowledge about outlays and cash inflows of available projects consists of much vagueness instead of randomness. Investment outlays and annual net cash flows of a project are usually predicted by using experts' knowledge. Fuzzy variables can overcome the difficulties in predicting these parameters. In this paper, capital budgeting problem with fuzzy investment outlays and fuzzy annual net cash flows is studied based on credibility measure. Net present value (NPV) method is employed, and two fuzzy chance-constrained programming models for capital budgeting problem are provided. A fuzzy simulation-based genetic algorithm is provided for solving the proposed model problems. Two numerical examples are also presented to illustrate the modelling idea and the effectiveness of the proposed algorithm.

  18. The diagnostic performance of CT-derived fractional flow reserve for evaluation of myocardial ischaemia confirmed by invasive fractional flow reserve: a meta-analysis.

    Science.gov (United States)

    Li, S; Tang, X; Peng, L; Luo, Y; Dong, R; Liu, J

    2015-05-01

    To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFRCT, with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for FFRCT were 89% (85-93%), 71% (65-75%), 70% (65-75%), 90% (85-93%), 3.31 (1.79-6.14), 0.16 (0.11-0.23), and 21.21 (9.15-49.15) at the patient-level, and 83% (78-63%), 78% (75-81%), 61% (56-65%), 92% (89-90%), 4.02 (1.84-8.80), 0.22 (0.13-0.35), and 19.15 (5.73-63.93) at the vessel-level. At per-patient analysis, FFRCT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR-, and DOR versus those of CTA. At per-vessel analysis, FFRCT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR-, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFRCT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. FFRCT, which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Validating a proxy for disease progression in metastatic cancer patients using prescribing and dispensing data.

    Science.gov (United States)

    Joshi, Vikram; Adelstein, Barbara-Ann; Schaffer, Andrea; Srasuebkul, Preeyaporn; Dobbins, Timothy; Pearson, Sallie-Anne

    2017-10-01

    Routine data collections are used increasingly to examine outcomes of real-world cancer drug use. These datasets lack clinical details about important endpoints such as disease progression. To validate a proxy for disease progression in metastatic cancer patients using prescribing and dispensing claims. We used data from a cohort study of patients undergoing chemotherapy who provided informed consent to the collection of cancer-treatment data from medical records and linkage to pharmaceutical claims. We derived proxy decision rules based on changes to drug treatment in prescription histories (n = 36 patients) and validated the proxy in prescribing data (n = 62 patients). We adapted the decision rules and validated the proxy in dispensing data (n = 109). Our gold standard was disease progression ascertained in patient medical records. Individual progression episodes were the unit of analysis for sensitivity and Positive Predictive Value (PPV) calculations and specificity and Negative Predictive Value (NPV) were calculated at the patient level. The sensitivity of our proxy in prescribing data was 74.3% (95% Confidence Interval (CI), 55.6-86.6%) and PPV 61.2% (95% CI, 45.0-75.3%); specificity and NPV were 87.8% (95% CI, 73.8-95.9%) and 100% (95% CI, 90.3-100%), respectively. In dispensing data, the sensitivity of our proxy was 64% (95% CI, 55.0-77.0%) and PPV 56.0% (95% CI, 43.0-69.0%); specificity and NPV were 81% (95% CI, 70.05-89.0%) and 91.0% (95% CI, 82.0-97.0%), respectively. Our proxy overestimated episodes of disease progression. The proxy's performance is likely to improve if the date of prescribing is used instead of date of dispensing in claims data and by incorporating medical service claims (such as imaging prior to drug changes) in the algorithm. Our proxy is not sufficiently robust for use in real world comparative effectiveness research for cancer medicines. © 2016 John Wiley & Sons Australia, Ltd.

  20. Systematic review of validated case definitions for diabetes in ICD-9-coded and ICD-10-coded data in adult populations.

    Science.gov (United States)

    Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Quan, Hude; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen

    2016-08-05

    With steady increases in 'big data' and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Evaluation of modified Alvarado scoring system and RIPASA scoring system as diagnostic tools of acute appendicitis.

    Science.gov (United States)

    Shuaib, Abdullah; Shuaib, Ali; Fakhra, Zainab; Marafi, Bader; Alsharaf, Khalid; Behbehani, Abdullah

    2017-01-01

    Acute appendicitis is the most common surgical condition presented in emergency departments worldwide. Clinical scoring systems, such as the Alvarado and modified Alvarado scoring systems, were developed with the goal of reducing the negative appendectomy rate to 5%-10%. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) scoring system was established in 2008 specifically for Asian populations. The aim of this study was to compare the modified Alvarado with the RIPASA scoring system in Kuwait population. This study included 180 patients who underwent appendectomies and were documented as having "acute appendicitis" or "abdominal pain" in the operating theatre logbook (unit B) from November 2014 to March 2016. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy, predicted negative appendectomy and receiver operating characteristic (ROC) curve of the modified Alvarado and RIPASA scoring systems were derived using SPSS statistical software. A total of 136 patients were included in this study according to our criteria. The cut-off threshold point of the modified Alvarado score was set at 7.0, which yielded a sensitivity of 82.8% and a specificity of 56%. The PPV was 89.3% and the NPV was 42.4%. The cut-off threshold point of the RIPASA score was set at 7.5, which yielded a 94.5% sensitivity and an 88% specificity. The PPV was 97.2% and the NPV was 78.5%. The predicted negative appendectomy rates were 10.7% and 2.2% for the modified Alvarado and RIPASA scoring systems, respectively. The negative appendectomy rate decreased significantly, from 18.4% to 10.7% for the modified Alvarado, and to 2.2% for the RIPASA scoring system, which was a significant difference (PAsian populations. It consists of 14 clinical parameters that can be obtained from a good patient history, clinical examination and laboratory investigations. The RIPASA scoring system is more accurate and specific than the modified Alvarado

  2. Materials and Devices Research of PPV-ZnO Nanowires for Heterojunction Solar Cells

    Directory of Open Access Journals (Sweden)

    Zhang Xiao-Zhou

    2012-01-01

    Full Text Available Bulk heterojunction photovoltaic devices, which use the conjugated polymer poly(2-methoxyl-5-(2′-ethylhexyloxy-1,4-phenylenevinylene (MEH-PPV as the electron donor and crystalline ZnO nanowires as the electron acceptor, have been studied in this work. The ZnO nanowires were prepared through a chemical vapor deposition mechanism. The dissolved MEH-PPV polymer was spin-coated onto the nanowires. The scanning electron microscope images showed that the ZnO nanowires were covered with a single layer of the polymer, and these materials were used to design a heterojunction solar cell. This solar cell displayed improved performance compared with the devices that were made from only the MEH-PPV polymer. This observed improvement is correlated with the improved electron transport that is perpendicular to the plane of the film. A solar power conversion efficiency of 1.37% was achieved under an AM1.5 illumination.

  3. Investigation on the Optical and Surface Morphology of Conjugated Polymer MEH-PPV:ZnO Nanocomposite Thin Films

    Directory of Open Access Journals (Sweden)

    Nurul Zayana Yahya

    2012-01-01

    Full Text Available Thin films of red color poly(2-methoxy-5(2′-ethylhexyloxy-phenylene vinylene (MEH-PPV containing different weight percent of ZnO nanoparticles were obtained by spin-coating techniques. The MEH-PPV:ZnO solutions were spin coated onto silicon and glass substrates. The spun MEH-PPV:ZnO thin films were then used to investigate optical properties by using ultraviolet-visible spectrometer (UV-Vis and photoluminescence spectrophotometer (PL. The morphologies were investigated by using field emission scanning electron microscopy (FESEM, while the identification of ZnO in the final product was determined by using energy-dispersive X-ray spectroscopy (EDS. The UV-Vis absorption band increases, while the optical bandgap decreases when the amount of ZnO nanoparticles increases. ZnO nanoparticles apparently have no effect on the conjugation segments of MEH-PPV. PL spectra show that the emission peak increases and slightly red shift as ZnO concentration increases. Based on SEM images of MEH-PPV:ZnO nanocomposite thin films, ZnO nanoparticles form agglomerated regions.

  4. PPV analysis and tension of spectral peak in an X radiation equipment for dosemeter calibration; Analise do PPV e tensao de pico espectral em um equipamento de raios-X para calibracao de dosimetros

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, P.M.C.; Santana, P.C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem; Lacerda, M.A.S.; Silva, T.A. da, E-mail: pmco@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-07-01

    Dosimetry laboratories around the world try to achieve metrology consistency between the X-rays beams for therapy and diagnostic detectors calibration. One of the parameters to characterize X-ray beam is the practical peak voltage (PPV) assessment. In this work were evaluated the PPV and spectral peak voltage in the potential constant X-ray equipment, that result in a mean difference of 1.4 %. (author)

  5. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma.

    Science.gov (United States)

    Tummers, W; van Schuppen, J; Langeveld, H; Wilde, J; Banderker, E; van As, A

    2016-06-01

    The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical decision-making regarding paediatric BAT. Children presented at the Trauma Unit of the Red Cross War Memorial Children's Hospital, Cape Town, after HET, and underwent both a physical examination and a FAST. The presence of free fluid in the abdomen and pelvis was assessed using a FAST. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) for identifying intraabdominal injury were calculated for the physical examination and the FAST, both individually and when combined. Seventy-five patients were included as per the criteria for HET as follows: pedestrian motor vehicle crashes (MVCs) ( n = 46), assault ( n = 14), fall from a height ( n = 9), MVC passenger ( n = 4) and other ( n = 2). The ages of the patients ranged from 3 months to 13 years. The sensitivity of the physical examination was 0.80, specificity 0.83, PPV 0.42 and NPV 0.96. The sensitivity of the FAST was 0.50, specificity 1.00, PPV 1.00 and NPV 0.93. Sensitivity increased to 0.90 when the physical examination was combined with the FAST. Nonoperative management was used in 73 patients. Two underwent an operation. A FAST should be performed in combination with a physical examination on every paediatric patient involved in HET to detect BAT. When both are negative, nonoperative management can be implemented without fear of missing a clinically significant injury. FAST is a safe, effective and easily accessible alternative to CT, which avoids ionising radiation and aids in clinical decision-making.

  6. Axillary fine needle aspiration cytology for pre-operative staging of patients with screen-detected invasive breast carcinoma.

    LENUS (Irish Health Repository)

    Hayes, Brian D

    2012-02-01

    INTRODUCTION: Fine needle aspiration cytology (FNAC) of radiologically abnormal axillary lymph nodes in patients with breast cancer can identify patients suitable for primary axillary clearance (AC) rather than sentinel node biopsy, enabling surgical axillary staging by a single operation. This study assessed the accuracy of FNAC in predicting positive axillary lymph nodes. METHODS: 161 patients with screen-detected invasive carcinoma and who had pre-operative FNAC of a radiologically abnormal axillary lymph node were identified from two screening units, The axillary FNAC reports were correlated with sentinel node biopsy and AC reports, and sensitivity, specificity, positive (PPV) and negative (NPV) predictive values were calculated. RESULTS: FNAC had a moderate sensitivity (66.3%) and NPV (71.8%), and a high specificity (98.7%) and PPV (98.3%). Most patients (86%) had a single axillary operation. The sensitivity was highest in grade 3 (81.8%) and ductal type (77.8%) tumours. The sensitivity was lower in tumours of special type (34.8%), grade 1 tumours (50%) and those without lymphovascular invasion (LVI) (55.9%). The NPV was highest in pT1 (86.7%) and in grade 1 (84.5%) tumours, and lowest (44%) in tumours with LVI. The PPV was 100% in grade 1 and 3 tumours, stage pT2 and pT3 tumours and those without LVI, and was high (>96%) in all other groups. In lymph-node-positive patients, the mean number of lymph nodes involved was higher in the case of a positive (6.4) than negative FNAC (4.4). CONCLUSIONS: FNAC of ultrasonically abnormal axillary lymph nodes achieved surgical staging by a single operation in most patients with screen-detected invasive breast carcinoma, with moderate sensitivity and high specificity.

  7. Role of PCR method using IS6110 primer in detecting Mycobacterium tuberculosis among the clinically diagnosed childhood tuberculosis patients at an urban hospital in Dhaka, Bangladesh

    Directory of Open Access Journals (Sweden)

    Senjuti Kabir

    2018-03-01

    Full Text Available Objective: Better methods are needed for the accurate detection of child tuberculosis (TB. This study compared different laboratory tests and evaluated IS6110 PCR for the detection of Mycobacterium tuberculosis (MTB among clinically diagnosed child TB patients. Methods: A total of 102 paediatric patients (<15 years old with clinically diagnosed TB were enrolled in this study. The patients were admitted to the icddr,b hospital in Dhaka between 2003 and 2005. Sputum/gastric lavage samples were collected for smear microscopy, culture (solid/Lowenstein–Jensen medium and liquid/MGIT, and IS6110 PCR testing. The sensitivity, specificity, and positive and negative predictive values (PPV, NPV of smear microscopy and PCR were compared to the two culture methods. Results: Three patients were positive on smear microscopy (2.9%. MTB was detected by conventional culture in 15.7% (16/102, liquid culture in 14% (14/100, and IS6110 PCR in 61.8% (63/102. PCR detected an additional 45 patients who were undetected with the three other tests. Compared to conventional and liquid culture, respectively, smear microscopy showed sensitivity of 18.8% and 21.4%, specificity of 100% individually, PPV of 100% individually, and NPV of 86.9% and 88.7%, whereas PCR had sensitivity of 87.5% and 92.9%, specificity of 43% individually, PPV of 22.2% and 21%, and NPV of 94.9% and 97.4%. Conclusions: PCR can be useful compared to smear microscopy and culture methods and is applicable as a rapid screening test for child TB. A larger scale study is required to determine its diagnostic efficacy in improving the detection of child TB in the presence and absence of severe malnutrition. Keywords: Child tuberculosis, Mycobacterium tuberculosis, IS6110 PCR

  8. Value of contrast-enhanced sonographic micro flow imaging for prostate cancer detection with t-PSA level of 4–10 ng/mL

    International Nuclear Information System (INIS)

    Guo, Yi-Fen; Li, Feng-Hua; Xie, Shao-Wei; Xia, Jian-Guo; Fang, Hua; Li, Hong-Li

    2012-01-01

    Objectives: To compare the efficiency of contrast-enhanced ultrasonographic micro flow imaging (MFI) with conventional transrectal ultrasound (TRUS) in detecting prostate cancer with serum total prostate-specific antigen (t-PSA) of 4.0–10.0 ng/mL. To evaluate the value of contrast-enhanced ultrasonographic MFI in detecting prostate cancer with t-PSA in diagnostic gray zone. Methods: 47 patients with t-PSA 4.0–10.0 ng/mL underwent gray scale, power Doppler TRUS and MFI examinations before ultrasound guided biopsies. Biopsies were performed at twelve sites in the base, the mid-gland and the apex of the prostate in each patient, when there was no abnormal ultrasound finding. When an abnormality was present at MFI, the biopsy specimen from the corresponding site was directed toward the abnormal finding. With histological results of prostate biopsy as reference standards, we assessed the cancer detection of these three methods. Results: 564 specimens were collected in this study, in which 101 were prostate cancer confirmed histologically. 152 of 564 specimens were demonstrated abnormal on MFI images, in which 71 were malignant and 81 were benign confirmed histologically. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) for MFI in detecting prostate caner were 70.3%, 82.5%, 80.3%, 46.7% and 92.7%, respectively. The sensitivity and NPV for MFI were significantly better than gray scale (38.6%, 86.9%) and power Doppler (32.7%, 86.0%) (P < 0.001) TRUS. Conclusions: Contrast-enhanced ultrasonographic MFI could significantly improve the detection rate of prostate cancer with t-PSA in diagnostic gray zone (4–10 ng/mL) than conventional ultrasound.

  9. Combination of serum angiopoietin-2 and uterine artery Doppler for prediction of preeclampsia.

    Science.gov (United States)

    Puttapitakpong, Ploynin; Phupong, Vorapong

    2016-02-01

    The aim of this study was to determine the predictive value of the combination of serum angiopoietin-2 (Ang-2) levels and uterine artery Doppler for the detection of preeclampsia in women at 16-18 weeks of gestation and to identify other pregnancy complications that could be predicted with these combined tests. Maternal serum Ang-2 levels were measured, and uterine artery Doppler was performed in 400 pregnant women. The main outcome was preeclampsia. The predictive values of this combination were calculated. Twenty-five women (6.3%) developed preeclampsia. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of uterine artery Doppler combined with serum Ang-2 levels for the prediction of preeclampsia were 24.0%, 94.4%, 22.2% and 94.9%, respectively. For the prediction of early-onset preeclampsia, the sensitivity, specificity, PPV and NPV were 57.1%, 94.1%, 14.8% and 99.2%, respectively. Patients with abnormal uterine artery Doppler and abnormal serum Ang-2 levels (above 19.5 ng ml(-1)) were at higher risk for preterm delivery (relative risk=2.7, 95% confidence interval 1.2-5.8). Our findings revealed that the combination of uterine artery Doppler and serum Ang-2 levels at 16-18 weeks of gestation can be used to predict early-onset preeclampsia but not overall preeclampsia. Thus, this combination may be a useful early second trimester screening test for the prediction of early-onset preeclampsia.

  10. Reliability and validity of a Chinese version of the HADS for screening depression and anxiety in psycho-cardiological outpatients.

    Science.gov (United States)

    Yang, Yuan; Ding, Rongjing; Hu, Dayi; Zhang, Fan; Sheng, Li

    2014-01-01

    The Hospital Anxiety and Depression Scale (HADS) has been used widely with cardiovascular patients. This study aims to examine the reliability and validity of a Chinese version of HADS among psycho-cardiological outpatients. One hundred psycho-cardiological outpatients were asked to complete the Chinese version of HADS and were then interviewed according to the Mini International Neuropsychiatric Interview, Version 5 (MINI). According to the MINI, 38 outpatients were diagnosed with major depression and 15 outpatients were diagnosed with an anxiety disorder. Compared with the MINI diagnoses, the optimum cutoff value of the anxiety subscale (HADS-A) was six (6) with a sensitivity of 81.6%, specificity of 75.8%, positive predictive value (PPV) of 54.0% and negative predictive value (NPV) of 91.9%; at the optimum cutoff value of nine (9), the depression subscale (HADS-D) had a sensitivity of 80.0%, specificity of 92.9%, PPV of 52.2% and NPV of 96.1%. The Cronbach's alpha coefficients of the HADS-A and HADS-D subscales were 0.753 and 0.764, respectively. The areas under the ROC curves of the HADS-A and the HADS-D subscales, as compared to MINI diagnoses of anxiety and depression, were 0.81 (SE = 0.05, 95%CI: [0.73, 0.90]) and 0.86 (SE = 0.05, 95%CI: [0.77, 0.94]), respectively. The HADS was found to be a reliable measurement tool for excluding depression and anxiety in psycho-cardiological outpatients. © 2014.

  11. A comparative study of the blend sign and the black hole sign on CT as a predictor of hematoma expansion in spontaneous intracerebral hemorrhage.

    Science.gov (United States)

    Li, Ruili; Yang, Mingfei

    2017-01-01

    Hematoma expansion (HE) is a major determinant of a poor outcome in patients with a spontaneous intracerebral hemorrhage (sICH). The blend sign and the black hole sign are distinguished from non-contrast CT (NCCT) in patients with sICH, and both are independent neuroimaging predictors of HE. The purpose of the current study was to compare the value of the two signs in the prediction of HE. We retrospectively analyzed clinical and neuroimaging data from 228 patients with sICH who were treated at our hospital between August 2015 and September 2017. NCCT of the brain was performed upon admission (within 6 h of the onset of symptoms) to identify the blend sign and the black hole sign. HE was determined based on CT during a follow-up 24 h later. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with which the blend sign and the black hole sign predicted HE were calculated. Receiver operating characteristic (ROC) curve analysis was performed in order to compare the accuracy of the two signs in predicting HE. The blend sign was identified in 46 patients (20.2%) and the black hole sign was identified in 38 (16.7%) based on NCCT of the brain upon admission. Of the 65 patients with HE, the blend sign was noted in 28 and the black hole sign was noted in 22. The blend sign had a sensitivity of predicting HE of 43.1%, a specificity of 89.0%, a PPV of 60.9%, and an NPV of 79.7%. In contrast, the black hole sign had a sensitivity of predicting HE of 33.9%, a specificity of 90.2%, a PPV of 57.9%, and an NPV of 77.4%. The area under the ROC curve was 0.660 for the blend sign and 0.620 for the black hole sign (p = 0.516). In conclusion, the blend sign and the black hole sign on CT are both good predictors of HE in patients with sICH, though the blend sign seems to have a higher level of accuracy.

  12. Towards a non-invasive method for early detection of testicular neoplasia in semen samples by identification of fetal germ cell-specific markers

    DEFF Research Database (Denmark)

    Hoei-Hansen, C E; Carlsen, E; Jorgensen, N

    2007-01-01

    /gonocyte markers is presented. METHODS: Immunocytological staining for AP-2gamma [and in some cases, OCT-3/4, NANOG or placental alkaline phosphatase (PLAP)] was performed in semen samples from 294 infertile patients and 209 patients with TGCTs or other diseases. RESULTS: Presence of AP-2gamma-stained cells...... but reduced in participants with overt TGCTs, perhaps because of obstruction. Assay specificity was 93.6%, positive predictive value (PPV) 83.3% and negative predictive value (NPV) 60.3%. CONCLUSIONS: Immunocytological semen analysis based on expression of fetal germ cell markers in exfoliated cells has...

  13. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  14. 3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients.

    Science.gov (United States)

    Rasper, Michael; Wildgruber, Moritz; Settles, Marcus; Eckstein, Hans-Henning; Zimmermann, Alexander; Reeps, Christian; Rummeny, Ernst J; Huber, Armin M

    2016-09-01

    To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.

  15. Resistance to Plum Pox Virus (PPV) in apricot (Prunus armeniaca L.) is associated with down-regulation of two MATHd genes.

    Science.gov (United States)

    Zuriaga, Elena; Romero, Carlos; Blanca, Jose Miguel; Badenes, Maria Luisa

    2018-01-27

    Plum pox virus (PPV), causing Sharka disease, is one of the main limiting factors for Prunus production worldwide. In apricot (Prunus armeniaca L.) the major PPV resistance locus (PPVres), comprising ~ 196 kb, has been mapped to the upper part of linkage group 1. Within the PPVres, 68 genomic variants linked in coupling to PPV resistance were identified within 23 predicted transcripts according to peach genome annotation. Taking into account the predicted functions inferred from sequence homology, some members of a cluster of meprin and TRAF-C homology domain (MATHd)-containing genes were pointed as PPV resistance candidate genes. Here, we have characterized the global apricot transcriptome response to PPV-D infection identifying six PPVres locus genes (ParP-1 to ParP-6) differentially expressed in resistant/susceptible cultivars. Two of them (ParP-3 and ParP-4), that encode MATHd proteins, appear clearly down-regulated in resistant cultivars, as confirmed by qRT-PCR. Concurrently, variant calling was performed using whole-genome sequencing data of 24 apricot cultivars (10 PPV-resistant and 14 PPV-susceptible) and 2 wild relatives (PPV-susceptible). ParP-3 and ParP-4, named as Prunus armeniaca PPVres MATHd-containing genes (ParPMC), are the only 2 genes having allelic variants linked in coupling to PPV resistance. ParPMC1 has 1 nsSNP, while ParPMC2 has 15 variants, including a 5-bp deletion within the second exon that produces a frameshift mutation. ParPMC1 and ParPMC2 are adjacent and highly homologous (87.5% identity) suggesting they are paralogs originated from a tandem duplication. Cultivars carrying the ParPMC2 resistant (mutated) allele show lack of expression in both ParPMC2 and especially ParPMC1. Accordingly, we hypothesize that ParPMC2 is a pseudogene that mediates down-regulation of its functional paralog ParPMC1 by silencing. As a whole, results strongly support ParPMC1 and/or ParPMC2 as host susceptibility genes required for PPV infection which

  16. The accuracy of clinical and biochemical estimates in defining the pre-test probability of pulmonary embolism

    International Nuclear Information System (INIS)

    Garvie, N.W.; Salehzahi, F.; Kuitert, L.

    2002-01-01

    Full text: The PIOPED survey confirmed the significance of the high probability ventilation/perfusion scan (HP V/Q scan) in establishing the diagnosis of pulmonary embolism (PE). In an interesting sentence, however, the authors indicated that 'the clinicians' assessment of the likelihood of PE (prior probability)' can substantially increase the predictive value of the investigation. The criteria used for this assessment were not published, and this statement conflicts with the belief that the clinical diagnosis of pulmonary embolism is unreliable. A medical history was obtained from 668 patients undergoing V/Q lung scans for suspected PE, and certain clinical features linked to PE were, when present, documented. These included pleuritic chest pain, haemoptysis, dyspnoea, clinical evidence of DVT, recent surgery and right ventricular strain pattern an ECG. D-Dimer levels and initial arterial oxygen saturation (PaO2) levels were also obtained. The prevalence of these clinical and biochemical criteria was then compared between HP (61) and normal (171) scans after exclusion of all equivocal or intermediate scan outcomes (436), (where lung scintigraphy was unable to provide a definite diagnosis). D-Dimer and/or oxygen saturation levels, were similarly compared in each group. A true positive result was scored for each clinical or biochemical criterion when linked with a high probability scan and, conversely, a false positive score when the scan outcome was normal. In this fashion, the positive predictive value (PPV) and, when appropriate, the negative predictive value (NPV) was obtained for each risk factor. In the context of PE, DVT and post-operative status prove the more reliable predictors of a high probability outcome. Where both features were present, the PPV rose to 0.57. A normal D-Dimer level was a better excluder of PE than a normal oxygen saturation level (NPV 0.78-v-0.44). Conversely, a raised D-Dimer, or reduced oxygen saturation, were both a little value in

  17. Spectroscopic identification of binary and ternary surface complexes of Np(V) on gibbsite.

    Science.gov (United States)

    Gückel, Katharina; Rossberg, André; Müller, Katharina; Brendler, Vinzenz; Bernhard, Gert; Foerstendorf, Harald

    2013-12-17

    For the first time, detailed molecular information on the Np(V) sorption species on amorphous Al(OH)3 and crystalline gibbsite was obtained by in situ time-resolved Attenuated Total Reflection Fourier-Transform Infrared (ATR FT-IR) and Extended X-ray Absorption Fine Structure (EXAFS) spectroscopy. The results consistently demonstrate the formation of mononuclear inner sphere complexes of the NpO2(+) ion irrespective of the prevailing atmospheric condition. The impact of the presence of atmospheric equivalent added carbonate on the speciation in solution and on the surfaces becomes evident from vibrational data. While the 1:1 aqueous carbonato species (NpO2CO3(-)) was found to become predominant in the circumneutral pH range, it is most likely that this species is sorbed onto the gibbsite surface as a ternary inner sphere surface complex where the NpO2(+) moiety is directly coordinated to the functional groups of the gibbsite's surface. These findings are corroborated by results obtained from EXAFS spectroscopy providing further evidence for a bidentate coordination of the Np(V) ion on amorphous Al(OH)3. The identification of the Np(V) surface species on gibbsite constitutes a basic finding for a comprehensive description of the dissemination of neptunium in groundwater systems.

  18. Guided in Situ Polymerization of MEH-PPV in Mesoporous Titania Photoanodes.

    Science.gov (United States)

    Minar, Norma K; Docampo, Pablo; Fattakhova-Rohlfing, Dina; Bein, Thomas

    2015-05-20

    Incorporation of conjugated polymers into porous metal oxide networks is a challenging task, which is being pursued via many different approaches. We have developed the guided in situ polymerization of poly(2-methoxy-5-(2'-ethylhexyloxy)-p-phenylenevinylene) (MEH-PPV) in porous titania films by means of surface functionalization. The controlled polymerization via the Gilch route was induced by an alkoxide base and by increasing the temperature. The selected and specially designed surface-functionalizing linker molecules mimic the monomer or its activated form, respectively. In this way, we drastically enhanced the amount of MEH-PPV incorporated into the porous titania phase compared to nonfunctionalized samples by a factor of 6. Additionally, photovoltaic measurements were performed. The devices show shunting or series resistance limitations, depending on the surface functionalization prior to in situ polymerization of MEH-PPV. We suggest that the reason for this behavior can be found in the orientation of the grown polymer chains with respect to the titania surface. Therefore, the geometry of the anchoring via the linker molecules is relevant for exploiting the full electronic potential of the conjugated polymer in the resulting hybrid composite. This observation will help to design future synthesis methods for new hybrid materials from conjugated polymers and n-type semiconductors to take full advantage of favorable electronic interactions between the two phases.

  19. Complexation of Np(V) in aqueous solutions

    International Nuclear Information System (INIS)

    Askarieh, M.M.; Hansford, M.I.; Staunton, S.; Rees, L.V.C.

    1993-01-01

    Various parameters affecting the diffusion coefficient of neptunium (V) in clay systems have been studied; e.g. clay mineralogy, the charge compensating cation in the clay, the ionic strength of a background perchlorate solution and the presence of three organic ligands. Several well established techniques have been employed to obtain stability constants for the neptunium systems; Np(V) EDTA and Np(V)/citrate, Np(V)/Aldrich Humic Acid (AHA), Np(V)/Gorleben Hulic Acid (GHA) and for the uranium systems U(VI)/EDTA, U(VI)/citrate and U(VI)/AHA. The experimental techniques employed were UV/visible spectroscopy, polarography, solvent extraction and ion exchange. (author). 50 refs., 24 figs., 9 tabs

  20. Simplification of childhood hypertension definition using blood pressure to height ratio among US youths aged 8-17years, NHANES 1999-2012.

    Science.gov (United States)

    Xi, Bo; Zhang, Meixian; Zhang, Tao; Li, Shuangshuang; Steffen, Lyn M

    2015-02-01

    The fourth report on the diagnosis, evaluation, and treatment of high blood pressure (BP) established high BP diagnostic criteria using age-, sex-, and height-specific BP percentiles. However, these BP criteria are quite difficult for use by professionals in the clinic or children and their parents. We aimed to simplify the hypertension diagnostic criteria using BP to height ratio (BP/height) in US children and adolescents aged 8-17years. Data were obtained from a national representative sample of 14,624 US children and adolescents aged 8-17years enrolled in the continuous National Health and Nutrition Examination Survey 1999-2012. SBP to height ratio (SBPHR) was calculated as SBP (mmHg)/height (cm) and DBP to height ratio (DBPHR) was calculated as DBP (mmHg)/height (cm). The BP diagnostic criteria recommended by the fourth report were used as the "gold standard". Receive operator characteristic curve analysis was used to choose the optimal thresholds of SBPHR and DBPHR. The optimal thresholds for identifying pre-hypertension and hypertension among children aged 8-12years and adolescents aged 13-17years were determined. The negative predictive value (NPV) for identifying hypertension was nearly 100% for both children and adolescents, although the positive predictive value (PPV) ranged from 19% to 35%. The NPV for identifying pre-hypertension ranged from 95% to 99% for children and adolescents, and the PPV ranged from 11% to 52%. The optimal thresholds of SBPHR and DBPHR are simple and accurate for screening elevated BP, although PPV is relatively low because of the low prevalence of childhood hypertension. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  2. APLIKASI NPV AT RISK DALAM ANALISIS KELAYAKAN FINANSIAL BUDIDAYA JAMUR TIRAM PUTIH DI KABUPATEN BOGOR JAWA BARAT

    Directory of Open Access Journals (Sweden)

    Tintin Sarianti

    2011-08-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} The purpose of this study where to analyze white oyster mushroom farming activity in Sub-Province of Bogor, to analyze financial feasibility of  white oyster mushroom farming activity for high and low land in Sub-Province of Bogor by NPV at Risk Method and to analyze the switching value for the changes of cost and benefit in  white oyster mushroom farming activity.  The data were collected from 6 farmer living in high and low land in Sub-Province of Bogor. The NPV at risk model and switching value analysis were used to analyze tha data.  The result of the study showed that white oyster mushroom farming activity for high and low land in Sub-Province of Bogor were feasible by financial that considered by investors in selecting the location to act the white oyster mushroom farming.  The risks like price risk, production risk in that activity have accomodated in to cash flow.  Accomodation for price risk was used the inflation rate and for production risk was used estimation for failure of crop in white oyster mushroom farming activity according the farmers in location.  Switching value was used for to analyze maximum changes in cost and benefit which were developing the cash flow.  The maximum changes describes that the changes admit of tolerated.  The result for switching value analysis showed that the decreasing of production of white oyster mushroom (fresh and baglog more sensitive than the others (decreasing of fresh white oyster mushroom price and increasing of varible

  3. Estimating the value of medical education: a net present value approach.

    Science.gov (United States)

    Kahn, Marc J; Nelling, Edward F

    2010-07-01

    Estimating the value of a medical education is a difficult undertaking. As student debt levels rise and the role of managed care in price-setting increases, the financial benefit of an MD degree comes into question. We developed a model using net present value (NPV) analysis for a range of annual costs of medical school attendance. Using this model, we determined the point at which pursuing a medical education is a "break-even" proposition from a financial perspective. The NPV of a medical education was positive for all annual costs of attendance from $10,000 to $100,000 and ranged from approximately $39,000 to $674,000 depending on the discount rate. Assuming a discount rate of 8%, only at an annual cost of attendance of $139,805 was the NPV = $0, which represents the break-even cost of medical education for a prospective student. Medical education is a financially advantageous undertaking for costs of attendance that far exceed even the most expensive schools in the United States. Our analysis suggests that based on economics, the supply of future physicians ought to be secure.

  4. Organic–inorganic hybrid nanocomposite for enhanced photo-sensing of PFO-DBT:MEH-PPV:PC{sub 71}BM blend-based photodetector

    Energy Technology Data Exchange (ETDEWEB)

    Zafar, Qayyum, E-mail: qayyumzafar@siswa.um.edu.my; Najeeb, Mansoor Ani, E-mail: animansoor@um.edu.my [University of Malaya, Low Dimensional Materials Research Centre (LDMRC), Department of Physics, Faculty of Science (Malaysia); Ahmad, Zubair, E-mail: zubairtarar@qu.edu.qa [Qatar University, Department of Electrical Engineering, College of Engineering (Qatar); Sulaiman, Khaulah, E-mail: khaulah@um.edu.my [University of Malaya, Low Dimensional Materials Research Centre (LDMRC), Department of Physics, Faculty of Science (Malaysia)

    2015-09-15

    The sensing parameters of previously reported PFO-DBT:MEH-PPV:PC{sub 71}BM ternary blend-based organic photodetector have been improved in the present study. Improvement has been successfully demonstrated by doping TiO{sub 2} nanoparticles in the PEDOT:PSS thin film. TiO{sub 2} nanoparticles of 50, 100 and 250 nm diameters have initially been dispersed in PEDOT:PSS, and the resulting suspension has been spun coated on glass substrates and subjected to UV/vis and PL study. Thin film of PEDOT:PSS–TiO{sub 2} (100 nm) has shown maximum quenching in PL spectra, along with fairly good visible-light absorption. For further studies, 5 wt% TiO{sub 2} (100 nm) nanoparticles dispersion in PEDOT:PSS has been utilized for the fabrication of ITO/PEDOT:PSS–TiO{sub 2}/PFO-DBT:MEH-PPV:PC{sub 71}BM/Al photodiode. The PEDOT:PSS–TiO{sub 2} suspension has been spun coated onto the ITO substrates primarily and annealed to densify the film by vaporizing water contents in the film. A ternary blend of PFO-DBT:MEH-PPV:PC{sub 71}BM in optimized volumetric ratio has been sequentially spun-cast to serve as a photoactive film. Significantly improved values of the sensing parameters such as responsivity (4 mA/W) and photo-to-dark current ratio (∼6.4 × 10{sup 4}) have also been found. Response/recovery times of the fabricated sensor remain almost the same (<1 s) as previously reported for PFO-DBT:MEH-PPV:PC{sub 71}BM ternary blend.

  5. Photophysics of conjugated polymers: interplay between Förster energy migration and defect concentration in shaping a photochemical funnel in PPV.

    Science.gov (United States)

    Saini, Sangeeta; Bagchi, Biman

    2010-07-21

    Recent single molecule experiments have suggested the existence of a photochemical funnel in the photophysics of conjugated polymers, like poly[2-methoxy-5-(2'-ethylhexyl)oxy-1,4-phenylenevinylene] (MEH-PPV). The funnel is believed to be a consequence of the presence of conformational or chemical defects along the polymer chain and efficient non-radiative energy transfer among different chromophore segments. Here we address the effect of the excitation energy dynamics on the photophysics of PPV. The PPV chain is modeled as a polymer with the length distribution of chromophores given either by a Gaussian or by a Poisson distribution. We observe that the Poisson distribution of the segment lengths explains the photophysics of PPV better than the Gaussian distribution. A recently proposed version of an extended 'particle-in-a-box' model is used to calculate the exciton energies and the transition dipole moments of the chromophores, and a master equation to describe the excitation energy transfer among different chromophores. The rate of energy transfer is assumed to be given here, as a first approximation, by the well-known Förster expression. The observed excitation population dynamics confirms the photochemical funneling of excitation energy from shorter to longer chromophores of the polymer chain. The time scale of spectral shift and energy transfer for our model polymer, with realistic values of optical parameters, is in the range of 200-300 ps. We find that the excitation energy may not always migrate towards the longest chromophore segments in the polymer chain as the efficiency of energy transfer between chromophores depends on the separation distance between the two and their relative orientation.

  6. Rapid detection of multidrug-resistant Mycobacterium tuberculosis using the malachite green decolourisation assay

    Science.gov (United States)

    Coban, Ahmet Yilmaz; Uzun, Meltem

    2013-01-01

    Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA) in detecting isoniazid (INH) and rifampicin (RIF) resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results. PMID:24402143

  7. Rapid detection of multidrug-resistant Mycobacterium tuberculosis using the malachite green decolourisation assay

    Directory of Open Access Journals (Sweden)

    Ahmet Yilmaz Coban

    2013-12-01

    Full Text Available Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA in detecting isoniazid (INH and rifampicin (RIF resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results.

  8. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A.; Hofman, P.A.M.; Oostenbrugge, R.J. van; Klotz, E.; Wildberger, J.E.

    2014-01-01

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  9. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    International Nuclear Information System (INIS)

    Anders, Katharina; Uder, Michael; Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias

    2013-01-01

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses ≥ 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  10. Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Fan, Zhanming; Yu, Wei; Lv, Biao; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China)

    2011-05-15

    To evaluate the feasibility, diagnostic accuracy, and radiation dose of CT coronary angiography (CTCA) in patients with atrial fibrillation (AF) using 320-detector CT. Thirty-seven patients with persistent AF and suspected coronary artery disease (CAD) were enrolled. All patients underwent both 320-detector CTCA and conventional coronary angiography (CCA). CT image quality and the presence of significant ({>=}50%) stenosis were evaluated by two radiologists blinded to the results of CCA. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using CCA as the reference standard. Differences in detection of coronary artery stenosis between 320-detector CTCA and CCA were evaluated with McNemar's test. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. In total 474 evaluated coronary segments, 459 (96.8%) segments were diagnostically evaluable. On per-segment analysis, sensitivity, specificity, PPV and NPV were 90.0% (18 of 20), 99.3% (436 of 439), 85.7% (18 of 21) and 99.5% (436 of 438). No significant difference was found between 320-detector CTCA and CCA on the detection of significant stenosis (P = 1.000). Effective doses of 320-detector CTCA was 13.0 {+-} 4.7 mSv. 320-detector CTCA is feasible and accurate in excluding CAD in patients with AF. (orig.)

  11. Thermographic skin temperature measurement compared with cold sensation in predicting the efficacy and distribution of epidural anesthesia.

    Science.gov (United States)

    Bruins, Arnoud A; Kistemaker, Kay R J; Boom, Annemieke; Klaessens, John H G M; Verdaasdonk, Rudolf M; Boer, Christa

    2018-04-01

    Due to the high rates of epidural failure (3-32%), novel techniques are required to objectively assess the successfulness of an epidural block. In this study we therefore investigated whether thermographic temperature measurements have a higher predictive value for a successful epidural block when compared to the cold sensation test as gold standard. Epidural anesthesia was induced in 61 patients undergoing elective abdominal, thoracic or orthopedic surgery. A thermographic picture was recorded at 5, 10 and 15 min following epidural anesthesia induction. After 15 min a cold sensation test was performed. Epidural anesthesia is associated with a decrease in skin temperature. Thermography predicts a successful epidural block with a sensitivity of 54% and a PPV of 92% and a specificity of 67% and a NPV of 17%. The cold sensation test shows a higher sensitivity and PPV than thermography (97 and 93%), but a lower specificity and NPV than thermography (25 and 50%). Thermographic temperature measurements can be used as an additional and objective method for the assessment of the effectiveness of an epidural block next to the cold sensation test, but have a low sensitivity and negative predictive value. The local decrease in temperature as observed in our study during epidural anesthesia is mainly attributed to a core-to-peripheral redistribution of body heat and vasodilation.

  12. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn's Disease.

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-04-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn's disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-valuewomen with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease.

  13. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Hofman, P.A.M. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, MhENS School for Mental Health and Neuroscience, Maastricht (Netherlands); Oostenbrugge, R.J. van [Maastricht University Medical Centre, Department of Neurology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands); Klotz, E. [Siemens Healthcare Sector, Computed Tomography, Forchheim (Germany); Wildberger, J.E. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands)

    2014-04-15

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  14. Ultrasonography versus magnetic resonance imaging in detecting and grading common extensor tendon tear in chronic lateral epicondylitis.

    Directory of Open Access Journals (Sweden)

    Artur Bachta

    Full Text Available To investigate the diagnostic performance and reliability of ultrasonography (US in detecting and grading common extensor tendon (CET tear in patients with chronic lateral epicondylitis (LE, using magnetic resonance imaging (MRI as the reference standard.The study comprised fifty-eight chronic LE patients. Each patient underwent US and MRI. CET status was classified as: high-grade tear (≥50% thickness, low-grade tear (<50% thickness, suspected tear (possible but not evident tear, no tear. Additionally, the following dichotomous scale was used: confirmed or unconfirmed CET tear. Relative US parameters (versus MRI for detecting CET tear included: sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and accuracy. The agreement between US and MRI findings was measured using the weighted Cohen kappa coefficient (κ.US showed moderate agreement with MRI in detecting and grading CET tear (κ = 0.49. Sensitivity, specificity, and accuracy in CET tear detecting by US were 64.52%, 85.19%, and 72.73%, respectively. PPV and NPV of US were 83.33% and 67.65%, respectively. No patient with unconfirmed CET tear on US had high-grade CET tear on MRI.Ultrasonography is a valuable imaging modality that can be used as a screening tool to exclude high-grade CET tear in chronic LE patients. Once a tear is evident on US, MRI should be considered to assess precisely the extent of tendon injury.

  15. Can Older Adults Accurately Report their Use of Physical Rehabilitation Services?

    Science.gov (United States)

    Freedman, Vicki A; Kasper, Judith D; Jette, Alan

    2018-04-10

    To explore accuracy of rehabilitation service use reports by older adults and variation in accuracy by demographic characteristics, time since use, duration, and setting (inpatient, outpatient, home). We calculate the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of survey-based measures from an observational panel study, the National Health and Aging Trends Study (NHATS), relative to measures developed from linked Medicare claims. Community-dwelling sample of Medicare fee-for-service beneficiaries in 2015 NHATS who were enrolled in Medicare Parts A and B for 12 months prior to their interview (N=4,228). Respondents were asked whether they received rehabilitation services in the last year and the duration and location of services. Healthcare Common Procedure Coding System codes and Revenue Center codes were used to identify Medicare-eligible rehabilitation service. Survey-based reports and Medicare claims yielded similar estimates of rehabilitation use over the last year. Self-reported measures had high sensitivity (77%) and PPV (80%) and even higher specificity and NPV (approaching 95%). However, in adjusted models sensitivity was lower for Black enrollees, the very old, and those with lower education levels. Survey-based measures of rehabilitation accurately captured use over the past year but differential reporting should be considered when characterizing rehabilitation use in certain subgroups of older Americans. Copyright © 2018. Published by Elsevier Inc.

  16. Comparison of 18F-fluorodeoxyglucose positron emission tomography/computed tomography, hydro-stomach computed tomography, and their combination for detecting primary gastric cancer

    International Nuclear Information System (INIS)

    Jang, Hye Young; Chung, Woo Suk; Song, E Rang; Kim, Jin Suk

    2015-01-01

    To retrospectively compare the diagnostic accuracy for detecting primary gastric cancer on positron emission tomography/computed tomography (PET/CT) and hydro-stomach CT (S-CT) and determine whether the combination of the two techniques improves diagnostic performance. A total of 253 patients with pathologically proven primary gastric cancer underwent PET/CT and S-CT for the preoperative evaluation. Two radiologists independently reviewed the three sets (PET/CT set, S-CT set, and the combined set) of PET/CT and S-CT in a random order. They graded the likelihood for the presence of primary gastric cancer based on a 4-point scale. The diagnostic accuracy of the PET/CT set, the S-CT set, and the combined set were determined by the area under the alternative-free receiver operating characteristic curve, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Diagnostic accuracy, sensitivity, and NPV for detecting all gastric cancers and early gastric cancers (EGCs) were significantly higher with the combined set than those with the PET/CT and S-CT sets. Specificity and PPV were significantly higher with the PET/CT set than those with the combined and S-CT set for detecting all gastric cancers and EGCs. The combination of PET/CT and S-CT is more accurate than S-CT alone, particularly for detecting EGCs.

  17. Comparison of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography, hydro-stomach computed tomography, and their combination for detecting primary gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hye Young; Chung, Woo Suk; Song, E Rang; Kim, Jin Suk [Konyang University Myunggok Medical Research Institute, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2015-01-15

    To retrospectively compare the diagnostic accuracy for detecting primary gastric cancer on positron emission tomography/computed tomography (PET/CT) and hydro-stomach CT (S-CT) and determine whether the combination of the two techniques improves diagnostic performance. A total of 253 patients with pathologically proven primary gastric cancer underwent PET/CT and S-CT for the preoperative evaluation. Two radiologists independently reviewed the three sets (PET/CT set, S-CT set, and the combined set) of PET/CT and S-CT in a random order. They graded the likelihood for the presence of primary gastric cancer based on a 4-point scale. The diagnostic accuracy of the PET/CT set, the S-CT set, and the combined set were determined by the area under the alternative-free receiver operating characteristic curve, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Diagnostic accuracy, sensitivity, and NPV for detecting all gastric cancers and early gastric cancers (EGCs) were significantly higher with the combined set than those with the PET/CT and S-CT sets. Specificity and PPV were significantly higher with the PET/CT set than those with the combined and S-CT set for detecting all gastric cancers and EGCs. The combination of PET/CT and S-CT is more accurate than S-CT alone, particularly for detecting EGCs.

  18. Coronary artery calcification score by multislice computed tomography predicts the outcome of dobutamine cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Janssen, Caroline H.C.; Vliegenthart, Rozemarijn; Overbosch, Jelle; Oudkerk, Matthijs; Kuijpers, Dirkjan; Dijkman, Paul R.M. van; Zijlstra, Felix

    2005-01-01

    The aim of this study was to determine whether a coronary artery calcium (CAC) score of less than 11 can reliably rule out myocardial ischemia detected by dobutamine cardiovascular magnetic resonance imaging (CMR) in patients suspected of having myocardial ischemia. In 114 of 136 consecutive patients clinically suspected of myocardial ischemia with an inconclusive diagnosis of myocardial ischemia, dobutamine CMR was performed and the CAC score was determined. The CAC score was obtained by 16-row multidetector computed tomography (MDCT) and was calculated according to the method of Agatston. The CAC score and the results of the dobutamine CMR were correlated and the positive predictive value (PPV) and the negative predictive value (NPV) of the CAC score for dobutamine CMR were calculated. A total of 114 (87%) of the patients were eligible for this study. There was a significant correlation between the CAC score and dobutamine CMR (p<0.001). Patients with a CAC score of less than 11 showed no signs of inducible ischemia during dobutamine CMR. For a CAC score of less than 101, the NPV and the PPV of the CAC score for the outcome of dobutamine CMR were, respectively, 0.96 and 0.29. In patients with an inconclusive diagnosis of myocardial ischemia a MDCT CAC score of less than 11 reliably rules out myocardial ischemia detected by dobutamine CMR. (orig.)

  19. Coronary artery calcification score by multislice computed tomography predicts the outcome of dobutamine cardiovascular magnetic resonance imaging.

    Science.gov (United States)

    Janssen, Caroline H C; Kuijpers, Dirkjan; Vliegenthart, Rozemarijn; Overbosch, Jelle; van Dijkman, Paul R M; Zijlstra, Felix; Oudkerk, Matthijs

    2005-06-01

    The aim of this study was to determine whether a coronary artery calcium (CAC) score of less than 11 can reliably rule out myocardial ischemia detected by dobutamine cardiovascular magnetic resonance imaging (CMR) in patients suspected of having myocardial ischemia. In 114 of 136 consecutive patients clinically suspected of myocardial ischemia with an inconclusive diagnosis of myocardial ischemia, dobutamine CMR was performed and the CAC score was determined. The CAC score was obtained by 16-row multidetector compued tomography (MDCT) and was calculated according to the method of Agatston. The CAC score and the results of the dobutamine CMR were correlated and the positive predictive value (PPV) and the negative predictive value (NPV) of the CAC score for dobutamine CMR were calculated. A total of 114 (87%) of the patients were eligible for this study. There was a significant correlation between the CAC score and dobutamine CMR (p<0.001). Patients with a CAC score of less than 11 showed no signs of inducible ischemia during dobutamine CMR. For a CAC score of less than 101, the NPV and the PPV of the CAC score for the outcome of dobutamine CMR were, respectively, 0.96 and 0.29. In patients with an inconclusive diagnosis of myocardial ischemia a MDCT CAC score of less than 11 reliably rules out myocardial ischemia detected by dobutamine CMR.

  20. Coronary artery calcification score by multislice computed tomography predicts the outcome of dobutamine cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, Caroline H.C.; Vliegenthart, Rozemarijn; Overbosch, Jelle; Oudkerk, Matthijs [University Hospital Groningen, Department of Radiology, Groningen (Netherlands); Kuijpers, Dirkjan [University Hospital Groningen, Department of Radiology, Groningen (Netherlands); Bronovo Hospital, Department of Radiology, The Hague (Netherlands); Dijkman, Paul R.M. van [Bronovo Hospital, Department of Cardiology, The Hague (Netherlands); Zijlstra, Felix [University Hospital Groningen, Department of Cardiology, Groningen (Netherlands)

    2005-06-01

    The aim of this study was to determine whether a coronary artery calcium (CAC) score of less than 11 can reliably rule out myocardial ischemia detected by dobutamine cardiovascular magnetic resonance imaging (CMR) in patients suspected of having myocardial ischemia. In 114 of 136 consecutive patients clinically suspected of myocardial ischemia with an inconclusive diagnosis of myocardial ischemia, dobutamine CMR was performed and the CAC score was determined. The CAC score was obtained by 16-row multidetector computed tomography (MDCT) and was calculated according to the method of Agatston. The CAC score and the results of the dobutamine CMR were correlated and the positive predictive value (PPV) and the negative predictive value (NPV) of the CAC score for dobutamine CMR were calculated. A total of 114 (87%) of the patients were eligible for this study. There was a significant correlation between the CAC score and dobutamine CMR (p<0.001). Patients with a CAC score of less than 11 showed no signs of inducible ischemia during dobutamine CMR. For a CAC score of less than 101, the NPV and the PPV of the CAC score for the outcome of dobutamine CMR were, respectively, 0.96 and 0.29. In patients with an inconclusive diagnosis of myocardial ischemia a MDCT CAC score of less than 11 reliably rules out myocardial ischemia detected by dobutamine CMR. (orig.)

  1. ADM3, TFF3 and LGALS3 are discriminative molecular markers in fine-needle aspiration biopsies of benign and malignant thyroid tumours

    Science.gov (United States)

    Karger, S; Krause, K; Gutknecht, M; Schierle, K; Graf, D; Steinert, F; Dralle, H; Führer, D

    2012-01-01

    Background: Previously, we reported a six-marker gene set, which allowed a molecular discrimination of benign and malignant thyroid tumours. Now, we evaluated these markers in fine-needle aspiration biopsies (FNAB) in a prospective, independent series of thyroid tumours with proven histological outcome. Methods: Quantitative RT–PCR was performed (ADM3, HGD1, LGALS3, PLAB, TFF3, TG) in the needle wash-out of 156 FNAB of follicular adenoma (FA), adenomatous nodules, follicular and papillary thyroid cancers (TC) and normal thyroid tissues (NT). Results: Significant expression differences were found for TFF3, HGD1, ADM3 and LGALS3 in FNAB of TC compared with benign thyroid nodules and NT. Using two-marker gene sets, a specific FNAB distinction of benign and malignant tumours was achieved with negative predictive values (NPV) up to 0.78 and positive predictive values (PPV) up to 0.84. Two FNAB marker gene combinations (ADM3/TFF3; ADM3/ACTB) allowed the distinction of FA and malignant follicular neoplasia with NPV up to 0.94 and PPV up to 0.86. Conclusion: We demonstrate that molecular FNAB diagnosis of benign and malignant thyroid tumours including follicular neoplasia is possible with recently identified marker gene combinations. We propose multi-centre FNAB studies on these markers to bring this promising diagnostic tool closer to clinical practice. PMID:22223087

  2. Validity of simple clinical and biological parameters as screening tool for sickle cell anemia for referral to tertiary center in highly resource constraints.

    Science.gov (United States)

    Kadima, Bertin Tshimanga; Gini-Ehungu, Jean Lambert; Mbutiwi, Fiston Ikwa Ndol; Bahati, John Tunda; Aloni, Michel Ntetani

    2017-11-01

    In the Democratic Republic of Congo, the incidence of sickle cell anemia (SCA) is estimated around 40 000 neonates per year. However, it is notoriously difficult to perform conventional electrophoresis in all hospitals and laboratories, especially at peripheral levels and rural area. A panel of multiple clinical and laboratory features that would enhance sickle cell disease were assessed for the detection of the disease in highly resource-scarce settings. A prospective study was conducted in Kinshasa. Venous blood samples were drawn from each study participant in order to determine the hematologic parameters, the peripheral smears, and the hemoglobin electrophoresis. We used Cohen's κ statistic to examine the agreement of each variable and diagnosis of sickle cell disease. A total of 807 patients were screened for sickle cell disease. Among these 807 children, 36 (4.5%) were homozygous for Hb S disease. The presence of at least 8% erythroblasts (PPV: 91%, NPV: 99%, sensitivity: 83.3%, specificity: 99.6%, κ value: .86) and sickle cells (PPV:100%, NPV: 98%, sensitivity: 50%, specificity: 100%, κ value: .66) in the peripheral blood smear had an acceptable agreement for sickle cell disease. These two biological markers may guide the clinician in the decision-making to initiate the management of the children as a sickle cell patient, pending confirmation of the disease by electrophoresis techniques. © 2017 Wiley Periodicals, Inc.

  3. Effect of intravitreal injection of Conbercept before PPV on complications and visual recovery in patients with PDR

    Directory of Open Access Journals (Sweden)

    Shao-Bing Lin

    2018-05-01

    Full Text Available AIM: To analyze the effect of intravitreal injection of Conbercept before pars plana vitrectomy(PPVon complications and visual recovery in patients with proliferative diabetic retinopathy(PDR. METHODS: Totally 94 patients with PDR(monocular onsetwere randomly divided into the experimental group(n=47and the control group(n=47. All patients were treated by PPV. The experimental group was treated with intravitreal injection of conbercept at 5-7d before PPV while the control group was not given the intervention. The surgical time, surgical procedures, complications and visual recovery in the two groups were observed and statistically analyzed. RESULTS: The operating time of PPV for the experimental group was significantly shorter than that for the control group(72.33±15.71min vs 91.06±19.29min, PPPPCONCLUSION: The intravitreal injection of conbercept before PPV has a positive effect on reducing the incidence of intraoperative complications and promoting postoperative visual recovery in patients with PDR.

  4. Usefulness of dynamic contrast-enhanced MRI in the evaluation of the viability of acute scaphoid fracture

    Energy Technology Data Exchange (ETDEWEB)

    Larribe, Maud [Hopital La Conception, Service d' imagerie medicale, Marseille (France); Hopital Sainte Marguerite, Service d' imagerie medicale, Marseille (France); Gay, Andre [Hopital La Conception, Service de chirurgie de la main, Marseille (France); Freire, Veronique [Centre hospitalier de l' Universite de Montreal, Department of Radiology, Notre-Dame Hospital, Montreal, QC (Canada); Bouvier, Corinne [Hopital La Timone, Service d' anatomopathologie, Marseille (France); Chagnaud, Christophe; Souteyrand, Philippe [Hopital La Conception, Service d' imagerie medicale, Marseille (France)

    2014-12-15

    To evaluate the usefulness of dynamic gadolinium-enhanced magnetic resonance imaging (MRI) for assessing the viability of the proximal pole of the scaphoid in patients with acute scaphoid fractures. Eighteen consecutive patients with acute scaphoid fracture who underwent dynamic gadolinium-enhanced MRI 7 days or less before surgery were prospectively included between August 2011 and December 2012. All patients underwent MR imaging with unenhanced images, enhanced images, and dynamic enhanced images. A radiologist first classified the MRI results as necrotic or viable based on T1- and T2-weighted images only, followed by a second blinded interpretation, this time including analysis of pre- and post-gadolinium administration images and a third blinded interpretation based on the time-intensity curve of the dynamic enhanced study. The standard of reference was the histologic assessment of a cylindrical specimen of the proximal pole obtained during surgery in all patients. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for unenhanced, enhanced, and dynamic gadolinium-enhanced MRI studies. The sensitivity, specificity, PPV, and NPV were 67, 67, 50, and 80 % for unenhanced images, 83, 100, 100, and 92 for enhanced images, and 83, 92, 83, and 92 for dynamic contrast-enhanced images. Our data are consistent with previously reported data supporting contrast-enhanced MRI for assessment of viability, and showing that dynamic imaging with time-intensity curve analysis does not provide additional predictive value over standard delayed enhanced imaging for acute scaphoid fracture. (orig.)

  5. Registration in the Danish Regional Nonmelanoma Skin Cancer Dermatology Database: completeness of registration and accuracy of key variables

    Directory of Open Access Journals (Sweden)

    Anna L Lamberg

    2010-05-01

    Full Text Available Anna L Lamberg1, Deirdre Cronin-Fenton2, Anne B Olesen11Department of Dermatology, 2Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, C, DenmarkObjective: To validate a clinical database for nonmelanoma skin cancer (NMSC with the aim of monitoring and predicting the prognosis of NMSC treated by dermatologists in clinics in the central and north Denmark regions.Methods: We assessed the completeness of registration of patients and follow-up visits, and positive predictive value (PPV, negative predictive value (NPV, sensitivity, and specificity of registrations in the database. We used the Danish Pathology Registry (DPR (n = 288 and a review of randomly selected medical records (n = 67 from two clinics as gold standards.Results: The completeness of registration of patients was 62% and 76% with DPR and medical record review as gold standards, respectively. The completeness of registration of 1st and 2nd follow up visits was 85% and 69%, respectively. The PPV and NPV ranged from 85% to 99%, and the sensitivity and specificity from 67% to 100%.Conclusion: Overall, the accuracy of variables registered in the NMSC database was satisfactory but completeness of patient registration and follow-up visits were modest. The NMSC database is a potentially valuable tool for monitoring and facilitating improvement of NMSC treatment in dermatology clinics. However, there is still room for improvement of registration of both patients and their follow-up visits.Keywords: nonmelanoma skin cancer, validation, database, positive predictive value, completeness

  6. Cost-Effectiveness and Validity Assessment of Cyscope Microscope, Quantitative Buffy Coat Microscope, and Rapid Diagnostic Kit for Malaria Diagnosis among Clinic Attendees in Ibadan, Nigeria

    Directory of Open Access Journals (Sweden)

    Abiodun Ogunniyi

    2016-01-01

    Full Text Available Background. Unavailability of accurate, rapid, reliable, and cost-effective malaria diagnostic instruments constitutes major a challenge to malaria elimination. We validated alternative malaria diagnostic instruments and assessed their comparative cost-effectiveness. Method. Using a cross-sectional study design, 502 patients with malaria symptoms at selected health facilities in Ibadan between January and April 2014 were recruited consecutively. We examined malaria parasites using Cyscope®, QBC, and CareStart™ and results were compared to light microscopy (LM. Validity was determined by assessing sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV. Costs per hour of use for instruments and turnaround time were determined. Result. Sensitivity of the instruments was 76.0% (CareStart, 95.0% (Cyscope, and 98.1% (QBC. Specificity was 96.0% (CareStart, 87.3% (Cyscope, and 85.5% (QBC. PPV were 65.2%, 67.5%, and 84.7%, while NPV were 93.6%, 98.6%, and 99.4% for CareStart, Cyscope, and QBC with Kappa values of 0.75 (CI = 0.68–0.82 for CareStart, 0.72 (CI = 0.65–0.78 for Cyscope, and 0.71 (CI = 0.64–0.77 for QBC. Average cost per hour of use was the lowest ($2.04 with the Cyscope. Turnaround time was the fastest with Cyscope (5 minutes. Conclusion. Cyscope fluorescent microscope had the shortest turnaround time and is the most cost-effective of all the malaria diagnostic instruments evaluated.

  7. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  8. Usefulness of dynamic contrast-enhanced MRI in the evaluation of the viability of acute scaphoid fracture

    International Nuclear Information System (INIS)

    Larribe, Maud; Gay, Andre; Freire, Veronique; Bouvier, Corinne; Chagnaud, Christophe; Souteyrand, Philippe

    2014-01-01

    To evaluate the usefulness of dynamic gadolinium-enhanced magnetic resonance imaging (MRI) for assessing the viability of the proximal pole of the scaphoid in patients with acute scaphoid fractures. Eighteen consecutive patients with acute scaphoid fracture who underwent dynamic gadolinium-enhanced MRI 7 days or less before surgery were prospectively included between August 2011 and December 2012. All patients underwent MR imaging with unenhanced images, enhanced images, and dynamic enhanced images. A radiologist first classified the MRI results as necrotic or viable based on T1- and T2-weighted images only, followed by a second blinded interpretation, this time including analysis of pre- and post-gadolinium administration images and a third blinded interpretation based on the time-intensity curve of the dynamic enhanced study. The standard of reference was the histologic assessment of a cylindrical specimen of the proximal pole obtained during surgery in all patients. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for unenhanced, enhanced, and dynamic gadolinium-enhanced MRI studies. The sensitivity, specificity, PPV, and NPV were 67, 67, 50, and 80 % for unenhanced images, 83, 100, 100, and 92 for enhanced images, and 83, 92, 83, and 92 for dynamic contrast-enhanced images. Our data are consistent with previously reported data supporting contrast-enhanced MRI for assessment of viability, and showing that dynamic imaging with time-intensity curve analysis does not provide additional predictive value over standard delayed enhanced imaging for acute scaphoid fracture. (orig.)

  9. T1 bright appendix sign to exclude acute appendicitis in pregnant women.

    Science.gov (United States)

    Shin, Ilah; An, Chansik; Lim, Joon Seok; Kim, Myeong-Jin; Chung, Yong Eun

    2017-08-01

    To evaluate the diagnostic value of the T1 bright appendix sign for the diagnosis of acute appendicitis in pregnant women. This retrospective study included 125 pregnant women with suspected appendicitis who underwent magnetic resonance (MR) imaging. The T1 bright appendix sign was defined as a high intensity signal filling more than half length of the appendix on T1-weighted imaging. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the T1 bright appendix sign for normal appendix identification were calculated in all patients and in those with borderline-sized appendices (6-7 mm). The T1 bright appendix sign was seen in 51% of patients with normal appendices, but only in 4.5% of patients with acute appendicitis. The overall sensitivity, specificity, PPV, and NPV of the T1 bright appendix sign for normal appendix diagnosis were 44.9%, 95.5%, 97.6%, and 30.0%, respectively. All four patients with borderline sized appendix with appendicitis showed negative T1 bright appendix sign. The T1 bright appendix sign is a specific finding for the diagnosis of a normal appendix in pregnant women with suspected acute appendicitis. • Magnetic resonance imaging is increasingly used in emergency settings. • Acute appendicitis is the most common cause of acute abdomen. • Magnetic resonance imaging is widely used in pregnant population. • T1 bright appendix sign can be a specific sign representing normal appendix.

  10. High-titer preparation of Bombyx mori nucleopolyhedrovirus (BmNPV displaying recombinant protein in silkworm larvae by size exclusion chromatography and its characterization

    Directory of Open Access Journals (Sweden)

    Tanaka Shigeyasu

    2009-06-01

    Full Text Available Abstract Background Budded baculoviruses are utilized for vaccine, the production of antibody and functional analysis of transmembrane proteins. In this study, we tried to produce and purify the recombinant Bombyx mori nucleopolyhedrovirus (rBmNPV-hPRR that displayed human (prorenin receptor (hPRR connected with FLAG peptide sequence on its own surface. These particles were used for further binding analysis of hPRR to human prorenin. The rBmNPV-hPRR was produced in silkworm larvae and purified from its hemolymph using size exclusion chromatography (SEC. Results A rapid method of BmNPV titer determination in hemolymph was performed using quantitative real-time PCR (Q-PCR. A correlation coefficient of BmNPV determination between end-point dilution and Q-PCR methods was found to be 0.99. rBmNPV-hPRR bacmid-injected silkworm larvae produced recombinant baculovirus of 1.31 × 108 plaque forming unit (pfu in hemolymph, which was 2.8 × 104 times higher than transfection solution in Bm5 cells. Its purification yield by Sephacryl S-1000 SF column chromatography was 264 fold from larval hemolymph at 4 days post-injection (p.i., but 35 or 39 fold at 4.5 or 5 days p.i., respectively. Protein patterns of rBmNPV-hPRR purified at 4 and 5 days were the same and ratio of envelope proteins (76, 45 and 35 kDa to VP39, one of nucleocapsid proteins, increased at 5 days p.i. hPRR was detected in only purified rBmNPV-hPRR at 5 days p.i.. Conclusion The successful purification of rBmNPV-hPRR indicates that baculovirus production using silkworm larvae and its purification from hemolymph by Sephacryl S-1000 SF column chromatography can provide an economical approach in obtaining the purified BmNPV stocks with high titer for large-scale production of hPRR. Also, it can be utilized for further binding analysis and screening of inhibitors of hPRR.

  11. The Design and Simulation of Natural Personalised Ventilation (NPV System for Multi-Bed Hospital Wards

    Directory of Open Access Journals (Sweden)

    Zulfikar A. Adamu

    2015-05-01

    Full Text Available Adequate ventilation is necessary for thermal comfort and reducing risks from infectious bio-aerosols in hospital wards, but achieving this with mechanical ventilation has carbon and energy implications. Natural ventilation is often limited to window-based designs whose dilution/mixing effectiveness are subject to constraints of wind speed, cross ventilation, and in the case of hospital wards, proximity of patients to external walls. A buoyancy-driven natural ventilation system capable of achieving dilution/mixing was shown to be feasible in a preceding study of novel system called natural personalised ventilation (NPV. This system combined both architecture and airflow engineering principles of space design and buoyancy and was tested and validated (salt-bath experiment for a single bed ward. This research extends the previous work and is proof-of-concept on the feasibility of NPV system for multi-bed wards. Two different four-bed ward types were investigated of using computational fluid dynamics (CFD simulations under wind-neutral conditions. Results predict that NPV system could deliver fresh air to multiple patients, including those located 10 m away from external wall, with absolute flow rates of between 32 L·s−1 and 54 L·s−1 for each patient/bed. Compared to same wards simulated using window design, ingress of airborne contaminants into patients’ breathing zone and summer overheating potential were minimised, while overall ward dilution was maximised. Findings suggest the NPV has potentials for enabling architects and building service engineers to decouple airflow delivery from the visualisation and illumination responsibilities placed upon windows.

  12. A cell clone strain from Mythimna separata (Lepidoptera: Noctuidae) highly susceptible to Autographa californica multiple nucleopolyhedrovirus (AcMNPV) and M. separata NPV (MsNPV).

    Science.gov (United States)

    Meng, Xiang-Qian; Zheng, Gui-Ling; Zhao, Chuan-De; Wan, Fang-Hao; Li, Chang-You

    2017-08-01

    In this study, we describe a cell line, Ms-10C, cloned from the line QAU-Ms-E-10 (simplified Ms-10), an embryonic line from Mythimna separata. The cloned cell line was significantly more sensitive to nucleopolyhedrovirus (NPV). Ms-10C cells were mainly spherical with a diameter of 14.42 ± 2.23 μm. DNA amplification fingerprinting (DAF) confirmed the profile of PCR-amplified bands of the cloned cell line was consistent with those of the parental cell line, Ms-10. The sequencing result of the mitochondrial cytochrome c oxidase I (mtCO I) fragment confirmed that the amplified 636-bps mtCOI fragment was 100% identical to that of M. separata. Its chromosomes exhibited the typical characters of lepidopteran cell lines. Its population doubling time was 42.2 h at 27°C. Ms-10C was more sensitive than Ms-10 to both Autographa californica multiple nucleopolyhedrovirus (AcMNPV) and M. separata nucleopolyhedrovirus (MsNPV). At 4 d post infection, the infection rates of two viruses reached 94.2 and 92.3%, respectively. The availability of this cell clone strain will provide a useful tool for the basic research on nucleopolyhedrovirus and for potential application in expression of recombinant proteins with baculovirus expression vector system.

  13. Net present value approaches for drug discovery.

    Science.gov (United States)

    Svennebring, Andreas M; Wikberg, Jarl Es

    2013-12-01

    Three dedicated approaches to the calculation of the risk-adjusted net present value (rNPV) in drug discovery projects under different assumptions are suggested. The probability of finding a candidate drug suitable for clinical development and the time to the initiation of the clinical development is assumed to be flexible in contrast to the previously used models. The rNPV of the post-discovery cash flows is calculated as the probability weighted average of the rNPV at each potential time of initiation of clinical development. Practical considerations how to set probability rates, in particular during the initiation and termination of a project is discussed.

  14. Usefulness of intestinal fatty acid-binding protein in predicting strangulated small bowel obstruction.

    Directory of Open Access Journals (Sweden)

    Hirotada Kittaka

    Full Text Available BACKGROUND: The level of intestinal fatty acid-binding protein (I-FABP is considered to be useful diagnostic markers of small bowel ischemia. The purpose of this retrospective study was to investigate whether the serum I-FABP level is a predictive marker of strangulation in patients with small bowel obstruction (SBO. METHODS: A total of 37 patients diagnosed with SBO were included in this study. The serum I-FABP levels were retrospectively compared between the patients with strangulation and those with simple obstruction, and cut-off values for the diagnosis of strangulation were calculated using a receiver operating characteristic curve. In addition, the sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV were calculated. RESULTS: Twenty-one patients were diagnosed with strangulated SBO. The serum I-FABP levels were significantly higher in the patients with strangulation compared with those observed in the patients with simple obstruction (18.5 vs. 1.6 ng/ml p<0.001. Using a cut-off value of 6.5 ng/ml, the sensitivity, specificity, PPV and NPV were 71.4%, 93.8%, 93.8% and 71.4%, respectively. An I-FABP level greater than 6.5 ng/ml was found to be the only independent significant factor for a higher likelihood of strangulated SBO (P =  0.02; odds ratio: 19.826; 95% confidence interval: 2.1560 - 488.300. CONCLUSIONS: The I-FABP level is a useful marker for discriminating between strangulated SBO and simple SBO in patients with SBO.

  15. Real-time ultrasound elastography: an assessment of enlarged cervical lymph nodes.

    Science.gov (United States)

    Lo, Wu-Chia; Cheng, Po-Wen; Wang, Chi-Te; Liao, Li-Jen

    2013-09-01

    To determine the efficacy of real-time elastography (RTE), compared with our previously proposed prediction model, in the detection of malignancy in cervical lymph nodes (LNs). One hundred and thirty-one patients underwent ultrasound-guided fine needle aspiration biopsy (ultrasound FNAB) after ultrasound and RTE evaluation. The formula of the RTE scoring system was a four-point visual scale, based on a previously determined model. The formula of the prediction model was: [Formula: see text]. An extended model was constructed with four previous predictors and elasticity scores, using a logistic regression model. Final histology revealed 77 benign and 54 malignant LNs. In the elasticity score system, sensitivity was 66.7 %, specificity was 57.1 %, the positive predictive value (PPV) was 52.2 % and the negative predictive value (NPV) was 71.0 %. In the prediction model system, sensitivity was 79.6 %, specificity was 92.2 %, the PPV was 87.8 % and the NPV was 86.6 %. When the extended and the original model were compared, the areas under the receiver operating characteristic curve (c-statistic) was 0.94 and 0.95, respectively (P > 0.05). Qualitative RTE offers no additional value over conventional ultrasound in predicting malignancy in cervical LNs. • An ultrasound system can help in the assessment of cervical lymph nodes. • Grey-scale and power Doppler ultrasound remain fundamental for neck nodal evaluation. • Qualitative real-time elastography provided no additional value compared with current prediction models.

  16. Resistance to BmNPV via overexpression of an exogenous gene controlled by an inducible promoter and enhancer in transgenic silkworm, Bombyx mori.

    Directory of Open Access Journals (Sweden)

    Liang Jiang

    Full Text Available The hycu-ep32 gene of Hyphantria cunea NPV can inhibit Bombyx mori nucleopolyhedrovirus (BmNPV multiplication in co-infected cells, but it is not known whether the overexpression of the hycu-ep32 gene has an antiviral effect in the silkworm, Bombyx mori. Thus, we constructed four transgenic vectors, which were under the control of the 39 K promoter of BmNPV (39 KP, Bombyx mori A4 promoter (A4P, hr3 enhancer of BmNPV combined with 39 KP, and hr3 combined with A4P. Transgenic lines were created via embryo microinjection using practical diapause silkworm. qPCR revealed that the expression level of hycu-ep32 could be induced effectively after BmNPV infection in transgenic lines where hycu-ep32 was controlled by hr3 combined with 39 KP (i.e., HEKG. After oral inoculation of BmNPV with 3 × 10(5 occlusion bodies per third instar, the mortality with HEKG-B was approximately 30% lower compared with the non-transgenic line. The economic characteristics of the transgenic lines remained unchanged. These results suggest that overexpression of an exogenous antiviral gene controlled by an inducible promoter and enhancer is a feasible method for breeding silkworms with a high antiviral capacity.

  17. Electrically conductive polyaniline as hole-injection layer for MEH-PPV:BT based polymer light emitting diodes

    International Nuclear Information System (INIS)

    Mohsennia, M.; Bidgoli, M. Massah; Boroumand, F. Akbari; Nia, A. Mohsen

    2015-01-01

    Graphical abstract: The PANI prepared at 15 °C with higher electrical conductivity has been used as hole-injection layer (HIL) in polymer light emitting diodes (PLEDs) with structure of ITO/PANI/MEHPPV:BT/Al. - Highlights: • Polyaniline (PANI) was synthesized at different temperatures (5, 10, 15, 20 and 25 °C). • The PANI sample with higher electrical conductivity was used as HIL in the PLED devices. • The PANI injection layer yielded higher current and lower turn-on voltage. • The effect of MEH-PPV:BT weight ratio on the PLED performance has been also investigated. • The J–V characteristics of the devices have been explained by FN tunneling model. - Abstract: Polyaniline (PANI) was synthesized by oxidative polymerization of aniline at different temperatures (5, 10, 15, 20 and 25 °C). The influence of polymerization temperature on sheet resistance of PANI was investigated, and the one prepared at 15 °C which showed lowest resistivity was chosen for further analysis. PANI was subsequently used as hole-injection layer (HIL) in polymer light emitting diodes (PLEDs) with structure of poly(ethylene terephthalate) (PET)/indium tin oxide (ITO)/PANI/MEH-PPV:BT/aluminum (Al). The PLEDs with emission layer made from a blend of poly [2-methoxy-5-(2′-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) and an electron transporting material, benzothiadiazole (BT), were fabricated at room conditions without using glove boxes. Our results showed an improvement in performance of our PANI-based fabricated PLEDs (PET/ITO/PANI/MEH-PPV:BT/Al) compared to the conventional devices that use poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PET/ITO/PEDOT:PSS/MEH-PPV:BT/Al) as their HIL. The hole injection barrier height (φ) of the fabricated PLEDs were then estimated using the Fowler–Nordheim (FN) field-emission tunneling theory and revealed that the barrier height decreases by increasing the BT concentration in the MEH-PPV:BT blend layer

  18. Moderate sensitivity and high specificity of emergency department administrative data for transient ischemic attacks.

    Science.gov (United States)

    Yu, Amy Y X; Quan, Hude; McRae, Andrew; Wagner, Gabrielle O; Hill, Michael D; Coutts, Shelagh B

    2017-09-18

    Validation of administrative data case definitions is key for accurate passive surveillance of disease. Transient ischemic attack (TIA) is a condition primarily managed in the emergency department. However, prior validation studies have focused on data after inpatient hospitalization. We aimed to determine the validity of the Canadian 10th International Classification of Diseases (ICD-10-CA) codes for TIA in the national ambulatory administrative database. We performed a diagnostic accuracy study of four ICD-10-CA case definition algorithms for TIA in the emergency department setting. The study population was obtained from two ongoing studies on the diagnosis of TIA and minor stroke versus stroke mimic using serum biomarkers and neuroimaging. Two reference standards were used 1) the emergency department clinical diagnosis determined by chart abstractors and 2) the 90-day final diagnosis, both obtained by stroke neurologists, to calculate the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the ICD-10-CA algorithms for TIA. Among 417 patients, emergency department adjudication showed 163 (39.1%) TIA, 155 (37.2%) ischemic strokes, and 99 (23.7%) stroke mimics. The most restrictive algorithm, defined as a TIA code in the main position had the lowest sensitivity (36.8%), but highest specificity (92.5%) and PPV (76.0%). The most inclusive algorithm, defined as a TIA code in any position with and without query prefix had the highest sensitivity (63.8%), but lowest specificity (81.5%) and PPV (68.9%). Sensitivity, specificity, PPV, and NPV were overall lower when using the 90-day diagnosis as reference standard. Emergency department administrative data reflect diagnosis of suspected TIA with high specificity, but underestimate the burden of disease. Future studies are necessary to understand the reasons for the low to moderate sensitivity.

  19. Valor preditivo dos escores de SNAP e SNAP-PE na mortalidade neonatal Predictive value of SNAP and SNAP-PE for neonatal mortality

    Directory of Open Access Journals (Sweden)

    Rita C. Silveira

    2001-12-01

    results. METHODS: All newborn infants admitted to our neonatal intensive care unit from March 1997 through December 1998 were prospectively evaluated just at completion of 24 hours of life for SNAP and SNAP-PE. Exclusion criteria were: death or discharge from the neonatal intensive care unit in the first 24 hours of life, congenital malformations incompatible with life, and outborn infants. RESULTS: 553 newborn infants were included in the study and 54 died. The median SNAP and SNAP-PE values were higher in those who died. Infants were allocated to five different raising ranges of SNAP and SNAP-PE severity. SNAP: up to 6, 7-11, 12-15, 16-24, higher than 24 (mortality: 3%, 11%, 29%, 48%,75%, respectively. SNAP-PE: up to 11, 12-23, 24-32, 33-50, higher than 50 (mortality: 3%, 10%, 53%, 78%, 83%, respectively. The optimal cut off points based on ROC curve were 12 for SNAP, and 24 for SNAP-PE. Sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV for death were figured out. SNAP 12: sensitivity 79.6%, specificity 71.7%, PPV 23.4%, NPV 97%. SNAP-PE 24: sensitivity 79.6%, specificity 80%, PPV 30%, NPV 97.3%. The area under the curve (Az were 81.4% for SNAP, and 85.1% for SNAP-PE, both statistically significant. There were no statistical differences between the two areas under the curve. CONCLUSIONS: SNAP and SNAP-PE are excellent predictors of neonatal survival. Therefore, we recommend their use in Neonatal Intensive Care Units.

  20. Increasing the luminous efficiency of an MEH-PPV based PLED using salmon DNA and single walled carbon nanotube

    International Nuclear Information System (INIS)

    Madhwal, Devinder; Singh, Inderpreet; Kumar, Jitender; Bhatia, C.S.; Bhatnagar, P.K.; Mathur, P.C.

    2011-01-01

    The combined effect of a salmon deoxyribonucleic acid (DNA)-based electron blocking layer and a single walled carbon nanotube (SWCNT) composite-based electron transport layer on the performance of a poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) polymer light emitting diode (PLED) has been examined. The SWCNT network in the composite layer improves electron injection from cathode and the DNA blocks these high mobility electrons at the electron blocking layer-polymer interface, leading to high luminance from the device. The luminous efficiency of the PLED is increased ∼20 times compared to that of a PLED using only MEH-PPV. - Highlights: → We report fabrication of a high luminous efficiency MEH-PPV based polymer LED. → Salmon DNA-CTMA layer is used to block injected electrons in the polymer layer. → MEH-PPV-SWCNT composite is used to transport electrons in the polymer layer. → The luminous efficiency of the polymer LED thereby improves about 20 times.

  1. Role of hyaluronic acid and laminin as serum markers for predicting significant fibrosis in patients with chronic hepatitis B

    Directory of Open Access Journals (Sweden)

    Feng Li

    Full Text Available OBJECTIVES: The aim of this study was to evaluate the diagnostic performance of serum HA and LN as serum markers for predicting significant fibrosis in CHB patients. METHODS: Serum HA and LN levels of 87 patients with chronic hepatitis B and 19 blood donors were assayed by RIA. Liver fibrosis stages were determined according to the Metavir scoring-system. The diagnostic performances of all indexes were evaluated by the receiver operating characteristic (ROC curves. RESULTS: Serum HA and LN concentrations increased significantly with the stage of hepatic fibrosis, which showed positive correlation with the stages of liver fibrosis (HA: r = 0.875, p < 0.001; LN: r = 0.610, p < 0.001. There were significant differences of serum HA and LN levels between F2-4 group in comparison with those in F0-F1 group (p < 0.001 and controls (p < 0.001, respectively. From ROC curves, 185.3 ng/mL as the optimal cut-off value of serum HA for diagnosis of significant fibrosis, giving its sensitivity, specificity, PPV, NPV, LR+, LR- and AC of 84.2%, 83.3%, 90.6%, 73.5%, 5.04, 0.19 and 83.9, respectively. While 132.7 ng/mL was the optimal cut-off value of serum LN, the sensitivity, specificity, PPV, NPV, LR+, LR- and AC were 71.9%, 80.0%, 87.2%, 60.0%, 3.59%, 0.35% and 74.7, respectively. Combinations of HA and LN by serial tests showed a perfect specificity and PPV of 100%, at the same time sensitivity declined to 63.2% and LR+ increased to 18.9, while parallel tests revealed a good sensitivity of 94.7%, NPV to 86.4%, and LR- declined to 0.08. CONCLUSIONS: Serum HA and LN concentrations showed positive correlation with the stages of liver fibrosis. Detection of serum HA and LN in predicting significant fibrosis showed good diagnostic performance, which would be further optimized by combination of the two indices. HA and LN would be clinically useful serum markers for predicting significant fibrosis in patients with chronic hepatitis B, when liver biopsy is

  2. Análise da capacidade diagnóstica dos exames preventivos do câncer de colo uterino Análisis de la capacidad diagnóstica de los exámenes preventivos del cáncer de cuello uterino Analysis of the capacity of preventive diagnostic tests for cervical cancer

    Directory of Open Access Journals (Sweden)

    Thaís Marques Lima

    2012-01-01

    Full Text Available OBJETIVO: Avaliar a capacidade diagnóstica dos exames citológicos, colposcópico e histológico na detecção de lesões pré-malignas. MÉTODOS: Estudo documental, retrospectivo, com abordagem quantitativa, realizado no Instituto de Prevenção do Câncer (IPC, em Fortaleza-CE. A população foi composta por prontuários de 112 mulheres que possuíam o resultado dos três exames. Adotou-se o teste de qui-quadrado e considerou-se estatisticamente significativo quando p OBJETIVO: Evaluar la capacidad diagnóstica de los exámenes citológicos, colposcópico e histológico en la detección de lesiones pre-malignas. MÉTODOS: Estudio documental, retrospectivo, con abordaje cuantitativo, realizado en el Instituto de Prevención del Cáncer (IPC, en Fortaleza-CE. La población estuvo compuesta por historias clínicas de 112 mujeres que poseían el resultado de los tres exámenes. Se adoptó el test de Chi-cuadrado y se consideró estadísticamente significativo cuando p OBJECTIVE: To evaluate the diagnostic capacity of cytological, colposcopic, and histological exams on the detection of premalignant lesions. METHODS: A documentary, retrospective study, with a quantitative approach, conducted in the Cancer Prevention Institute (CPI, in Fortaleza-CE. The population consisted of medical records of 112 women who had the results of these three exams. We adopted the chi-square test and considered it statistically significant when p <0.05. We applied sensitivity and specificity, positive predictive value (PPV and negative predictive value (NPV for cytology and colposcopy. RESULTS: From the comparison between the diagnostic tests, we observed that cytology obtained a sensitivity of 89.8%, a specificity of 35.7%, a PPV of 90.7% and an NPV of 33.3%. Colposcopy achieved a sensitivity of 84.7%, a specificity of 50%, a PPV of 92.2% and an NPV of 31.8%. CONCLUSION: We found that these tests presented sensitivity and specificity that can alternate with one

  3. Implementation of a new CT colonography service: 5 Year experience

    International Nuclear Information System (INIS)

    Lung, P.F.C.; Burling, D.; Kallarackel, L.; Muckian, J.; Ilangovan, R.; Gupta, A.; Marshall, M.; Shorvon, P.; Halligan, S.; Bhatnagar, G.; Bassett, P.; Taylor, S.A.

    2014-01-01

    Aim: To describe our experience using a 5 year audit of computed tomography colonography (CTC) practice and identify factors that influence diagnostic performance to guide implementation in other centres. Material and methods: Consecutive patients referred for CTC at a single institution over a 5 year period were identified, and reporting rates and positive predictive value (PPV) calculated for small polyps, large polyps, and colorectal cancer. Diagnostic performance was compared using the Chi-squared test, and trends over time were examined with logistic regression. The effect of faecal tagging and an intravenous spasmolytic were investigated using Fisher's exact test. Results: In total, 4355 CTC examinations were performed. Overall reporting rates and PPV were 17% and 92%, respectively. Negative predictive value (NPV) for cancer was 99.9%. A significant decrease in reporting rate (p < 0.001) was accompanied by an increase in PPV for small polyps (p = 0.02) following the introduction of faecal tagging. Adequacy rates for CTC improved over time (96% to 99%), with improved adequacy rates when using a spasmolytic, 98% versus 96% without. A significant difference in reporting rates, but not PPV, was found between radiologists. Conclusion: Accurate colonic investigation using CTC can be delivered safely to a high-risk patient population at a single centre. Faecal tagging and an intravenous spasmolytic improve diagnostic performance

  4. Evaluation of national health-care related infection criteria for epidemiological surveillance in neonatology.

    Science.gov (United States)

    Ferreira, Janita; Bouzada, Maria C F; Jesus, Lenize A de; Cortes, Maria da Conceição Werneck; Armond, Guilherme A; Clemente, Wanessa T; Anchieta, Lêni M; Romanelli, Roberta M C

    2014-01-01

    to assess the use of the Brazilian criteria for reporting of hospital-acquired infections (HAIs) in the neonatal unit and compare them with the criteria proposed by the National Healthcare Safety Network (NHSN). this was a cross-sectional study conducted from 2009 to 2011. It included neonates with HAI reporting by at least one of the criteria. Statistical analysis included calculation of incidence density of HAIs, distribution by weight, and by reporting criterion. Analysis of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the national criteria was performed considering the NHSN as the gold standard, with agreement assessed by kappa. a total of 882 newborns were followed, and 330 had at least one infection notified by at least one of the criteria. A total of 522 HAIs were reported, regardless of the criteria. An incidence density of 27.28 infections per 1,000 patient-days was observed, and the main topographies were sepsis (58.3%), candidiasis (15.1%), and conjunctivitis (6.5%). A total of 489 (93.7%) were notified by both criteria, eight infections were notified only by the national criteria (six cases of necrotizing enterocolitis and two cases of conjunctivitis), and 25 cases of clinical sepsis were reported by NHSN criteria only. The sensitivity, specificity, PPV, and NPV were 95.1%, 98.6%, 98.4%, and 95.7%, respectively, for all topographies, and were 91.8%, 100%, 100%, and 96.3% for the analysis of sepsis. Kappa analysis showed an agreement of 96.9%. there was a high rate of agreement between the criteria. The use of the national criteria facilitates the reporting of sepsis in newborns, and can help to improve the specificity and PPV. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  5. Post-treatment PET/CT and p16 status for predicting treatment outcomes in locally advanced head and neck cancer after definitive radiation

    Energy Technology Data Exchange (ETDEWEB)

    Awan, Musaddiq J.; Machtay, Mitchell; Yao, Min [Case Western Reserve University and University Hospitals, Department of Radiation Oncology, Cleveland, OH (United States); Lavertu, Pierre; Zender, Chad; Rezaee, Rod; Fowler, Nicole [University Hospitals, Department of Otolaryngology and Head and Neck Surgery, Cleveland, OH (United States); Karapetyan, Lilit; Gibson, Michael [University Hospitals, Department of Medical Oncology, Cleveland, OH (United States); Wasman, Jay [University Hospitals, Department of Pathology, Cleveland, OH (United States); Faulhaber, Peter [University Hospitals, Department of Nuclear Medicine and Radiology, Cleveland, OH (United States)

    2017-06-15

    To retrospectively review post-treatment (post-tx) FDG-PET/CT scans in patients with advanced head and neck squamous cell carcinoma (HNSCC) and known p16 status, treated with definitive (chemo)radiation (RT). A total of 108 eligible patients had N2A or greater HNSCC treated with chemoRT from August 1, 2008, to February 28, 2015, with post-tx PET/CT within 6 months after RT. Kaplan-Meier curves, log-rank statistics, and Cox proportional hazards regression were used for statistical analysis. Median follow-up was 2.38 years. Sixty-eight (63.0%) patients had p16+ and 40 (37.0%) had p16- status. Two-year overall survival and recurrence-free survival were 93.4% and 77.8%, respectively. The negative predictive value (NPV) of PET/CT for local recurrence (LR) was 100%. The NPV for regional recurrence (RR) was 96.5% for all patients, 100% for p16+ patients, and 88.5% for p16- patients. The positive predictive value (PPV) of PET/CT for recurrence was 77.3% for all patients, 50.0% for p16+, and 78.6% for p16-. The PPV for LR was 72.7% for all patients, 50.0% for p16+ patients, and 72.7% for p16- patients. The PPV for RR was 50.0% for all patients, 33% for p16+, and 66.6% for p16-. Post-tx PET/CT and p16 status were independent predictors of recurrence-free survival (p < 0.01). Post-tx PET/CT predicts treatment outcomes in both p16 + and p16- patients, and does so independently of p16 status. P16- patients with negative PET have a 10% risk of nodal recurrence, and closer follow-up in these patients is warranted. (orig.)

  6. [Concurrent validity and efficiency of the CBTD for the surveillance of mental health on children and adolescents at a primary health care center in Mexico].

    Science.gov (United States)

    Caraveo-Anduaga, Jorge Javier; López-Jiménez, Jorge Luis; Soriano-Rodríguez, Alejandra; López-Hernández, Julio Cesar; Contreras-Garza, Aurora; Reyes-Mejía, Arlet

    2011-01-01

    Child psychopathology can e understood as normal development gone awry. Attention to psychosocial and behavioural problems has long been recommended as a critical component of well-child care. Likewise, screening for emotional and behavioural problems has been recommended as a routine part of health supervision visits. Different screening instruments have been developed and are widely used. Most of them include a dimensional measurement for internalizing, externalizing, and attention problems, but there is also the need to develop screening algorithms for specific psychiatric syndromes. To present the concurrent validity and efficiency indicators of the Brief Screening and Diagnostic Questionnaire, CBTD, in a primary care health center (PCHC) at Mexico City, as a tool for the surveillance of mental health on children and adolescents. A sample of 667 consecutive patients (4-16 years old) whose parents responded the CBTD. All patients who obtained a score of five or more symptoms were clinically interviewed using the MINI-KID, together with one of every ten subjects with a lower score. Efficiency showed a sensitivity of 68%, specificity of 82%, positive predictive value (PPV) of 88% and a negative predictive value (NPV) of 57%. When two or more CBTD syndromes are present the PPV is almost 100%. Concurrent validity showed a fair agreement for most of the CBTD syndromes as compared to DSM-IV diagnoses. Syndromes suggesting brain abnormalities, not included in scales of other widely used screening instruments, showed a PPV of 92% and NPV of 96.4%. The screening results from the CBTD can be used either categorically or dimensionally facilitating the surveillance of mental health on children and adolescents as different syndromatic profiles can be identified and followed for evaluation, along with complementary familial and psychosocial information.

  7. Evaluation of national health-care related infection criteria for epidemiological surveillance in neonatology

    Directory of Open Access Journals (Sweden)

    Janita Ferreira

    2014-07-01

    Full Text Available OBJECTIVE: to assess the use of the Brazilian criteria for reporting of hospital-acquired infections (HAIs in the neonatal unit and compare them with the criteria proposed by the National Healthcare Safety Network (NHSN. METHODS: this was a cross-sectional study conducted from 2009 to 2011. It included neonates with HAI reporting by at least one of the criteria. Statistical analysis included calculation of incidence density of HAIs, distribution by weight, and by reporting criterion. Analysis of sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV for the national criteria was performed considering the NHSN as the gold standard, with agreement assessed by kappa. RESULTS: a total of 882 newborns were followed, and 330 had at least one infection notified by at least one of the criteria. A total of 522 HAIs were reported, regardless of the criteria. An incidence density of 27.28 infections per 1,000 patient-days was observed, and the main topographies were sepsis (58.3%, candidiasis (15.1%, and conjunctivitis (6.5%. A total of 489 (93.7% were notified by both criteria, eight infections were notified only by the national criteria (six cases of necrotizing enterocolitis and two cases of conjunctivitis, and 25 cases of clinical sepsis were reported by NHSN criteria only. The sensitivity, specificity, PPV, and NPV were 95.1%, 98.6%, 98.4%, and 95.7%, respectively, for all topographies, and were 91.8%, 100%, 100%, and 96.3% for the analysis of sepsis. Kappa analysis showed an agreement of 96.9%. CONCLUSION: there was a high rate of agreement between the criteria. The use of the national criteria facilitates the reporting of sepsis in newborns, and can help to improve the specificity and PPV.

  8. Accuracy and role of contrast-enhanced CT in diagnosis and surgical planning in 88 soft tissue tumours of extremities

    International Nuclear Information System (INIS)

    Verga, Lucia; Robiati, Sara; De Marchi, Armanda; Martorano, Domenico; Faletti, Carlo; Brach del Prever, Elena Maria; Linari, Alessandra; Boffano, Michele; Piana, Raimondo

    2016-01-01

    Soft tissue tumours (STT) require accurate diagnosis in order to identify potential malignancies. Preoperative planning is fundamental to avoid inadequate treatments. The role of contrast-enhanced computed tomography (CT) for local staging remains incompletely assessed. Aims of the study were to evaluate CT accuracy in discriminating active from aggressive tumours compared to histology and evaluate the role of CT angiography (CTA) in surgical planning. This retrospective cohort series of 88 cases from 1200 patients (7 %) was locally studied by contrast-enhanced CT and CTA in a referral centre: 74 malignant tumours, 14 benign lesions. Contrast-enhancement patterns and relationship of the mass with major vessels and bone were compared with histology on surgically excised samples. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) were evaluated in discriminating active from aggressive tumours. Sensitivity in differentiating aggressive tumours from active lesions was 89 %, specificity 84 %, PPV 90 %, NPV 82 %. The relationship between mass and major vessels/bone was fundamental for surgical strategy respectively in 40 % and in 58 % of malignant tumours. Contrast-enhanced CT and CTA are effective in differentiating aggressive masses from active lesions in soft tissue and in depicting the relationship between tumour and adjacent bones and major vessels. (orig.)

  9. Diagnostic performance of fluorine-18-fluorodeoxyglucose positron emission tomography in the postchemotherapy management of patients with seminoma: systematic review and meta-analysis.

    Science.gov (United States)

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Caldarella, Carmelo; Bertagna, Francesco; Giovanella, Luca

    2014-01-01

    To meta-analyze published data about the diagnostic performance of fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the postchemotherapy management of patients with seminoma. A comprehensive literature search of studies published through January 2014 on this topic was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity and specificity, positive and negative predictive values (PPV and NPV), accuracy, and area under the summary ROC curve (AUC) of (18)F-FDG-PET or PET/CT on a per examination-based analysis were calculated. Subgroup analyses considering the size of residual/recurrent lesions were carried out. Nine studies including 375 scans were selected. The pooled analysis provided the following results: sensitivity 78% (95% confidence interval (95% CI): 67-87%), specificity 86% (95% CI: 81-89%), PPV 58% (95% CI: 48-68%), NPV 94% (95% CI: 90-96%), and accuracy 84% (95% CI: 80-88%). The AUC was 0.90. A better diagnostic accuracy of (18)F-FDG-PET or PET/CT in evaluating residual/recurrent lesions >3 cm compared to those sources of false-negative and false-positive results should be considered. The literature focusing on this setting still remains limited and cost-effectiveness analyses are warranted.

  10. Validity of bacterial pneumonia score for predicting bacteremia in children with pneumonia

    Directory of Open Access Journals (Sweden)

    Rosalia Theodosia Daten Beyeng

    2011-12-01

    Full Text Available Background Bacteremia in children with pneumonia reflects a severe condition, with longer duration of hospital care and potentially lethal complications. Early detection of bacteremia in patients with pneumonia may reduce serious complications. Few bacteremia screening tools have been widely used in chidren with pneumonia. One of those tools is the bacterial pneumonia score (BPS. Objective To assess the validity of the bacterial pneumonia score for predicting bacteremia in pediatric patients with pneumonia. Methods A diagnostic test was conducted on children aged 1 to 60 months hospitalized with pneumonia from December 2009 to August 2010. Subjects were collected consecutively. Pneumonia was diagnosed using the World Healt Organization (WHO criteria. Subjects underwent complete blood counts and blood culture examinations at admission. Statistical analyses included sensitivity, specificity, positive and negative predictive value (PPV/NPV, positive and negative likelihood ratio (PLR/NLR, and post-test probability. Results Our study included 229 children. Based on BPS with a cut-off score of ≥ 4, the sensitivity was 83.3%, specificity 49.7%, PPV 8.4%, NPV 98.2%, PLR 1.66, NLR 0.31, and post-test probability 8.4% for detecting bacteremia in pediatric pneumonia patients. Conclusion BPS can not be used for predicting bacteremia in pediatric patients with pneumonia.

  11. Validation of an Arab name algorithm in the determination of Arab ancestry for use in health research.

    Science.gov (United States)

    El-Sayed, Abdulrahman M; Lauderdale, Diane S; Galea, Sandro

    2010-12-01

    Data about Arab-Americans, a growing ethnic minority, are not routinely collected in vital statistics, registry, or administrative data in the USA. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically based probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. We used data from all Michigan birth certificates between 2000 and 2005. Fathers' surnames and mothers' maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Statewide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and an NPV of 98.6%. Both the false-positive and false-negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false-positive rate increased and false-negative rate decreased. The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA.

  12. Comparison between two.magnetic resonance sequences (spin-echo and gradient-echo) in the analysis of lesions of the knee joint meniscus

    International Nuclear Information System (INIS)

    Marti-Bonati, L.; Casillas, C.

    1999-01-01

    To compare the diagnostic reliability, the proportion of common diagnoses and the degree of agreement between the results of two magnetic resonance (MR) sequences in the diagnosis of lesions of the meniscus of the knee. One hundred consecutive patients were studied prospectively by MR (1,5 Teslas). All of them underwent T1-weighted spin-echo and T1 and T2-weighted gradient-echo sequences. The final diagnosis was based on the combined results of four imaging sequences. The sensitivity, specificity, positive predictive value (PPV) and negative predictive (NPV) in terms of the final diagnosis were calculated for each meniscus and MR technique. The chi.squared test and kappa test were employed for the statistical analysis. There were discrepancies between the final diagnosis and the spin-echo sequence in 4 cases and between the final diagnosis and the gradient-echo sequences in 5 Both spin-echo and gradient-echo sequences showed the same diagnostic reliabilities: sensitivity of 0.98, specificity of 0.99, PPV of 0.98 and NPV of 0.99. The correlation between the two sequences was highly significant (chi-squared, p < 0.001) with a very high rate of agreement (kappa=0.84). The two sequences can be considered equally reliable in the study of meniscal lesions. (Author) 7 refs

  13. Study of solvent-conjugated polymer interactions by polarized spectroscopy: MEH-PPV and Poly(9,9'-dioctylfluorene-2,7-diyl)

    International Nuclear Information System (INIS)

    Cossiello, Rafael F.; Susman, Mariano D.; Aramendia, Pedro F.; Atvars, Teresa D.Z.

    2010-01-01

    Absorption, emission, and anisotropy measurements were performed on poly-[2-methoxy-5(2'-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV) and poly-(9,9'-dioctylfluorene-2,7-diyl) (PF) solutions of various solvents, and in thin films deposited from them. The good correlation of MEH-PPV absorption and emission energy with Hildebrandt's dispersive parameter indicate that dispersive forces regulate the effective extent of the luminophore. The excitation and the emission spectra of α and β chains can be distinguished in PF solutions using the steady-state anisotropy. PF films show greater memory effect from the solutions from which they were spun than MEH-PPV. Anisotropy of MEH-PPV is very low, both in solutions and in films reflecting efficient energy migration. Anisotropy of PF in solutions and films demonstrates great differences in energy transfer efficiency within the α and β phases, while there is no energy transfer between these chain conformations.

  14. [Design of a preoperative predictive score for choledocholithiasis].

    Science.gov (United States)

    Bueno Lledó, Jose; Ibáñez Cirión, Jose Luis; Torregrosa Gallud, Antonio; López Andújar, Rafael

    2014-11-01

    Choledocholithiasis is the most common cause of obstructive jaundice and occurs in 5-10% of patients with cholelithiasis. To design a preoperative predictive score for choledocholithiasis. A prospective study was carried out in 556 patients admitted to our department for biliary disease. Preoperative clinical, laboratory, and ultrasound variables were compared between patients without choledocholithiasis and 65 patients with this diagnosis. A multivariate logistic analysis was performed to obtain a predictive model of choledocholithiasis, determining sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Predictors of choledocholithiasis were the presence of a prior history of biliary disease (history of biliary colic, acute cholecystitis, choledocholithiasis or acute biliary pancreatitis) (p=0.021, OR=2.225, 95% CI: 1.130-4.381), total bilirubin values >4mg/dl (p=0.046, OR=2.403, 95% CI: 1.106-5.685), alkaline phosphatase values >150mg/dl (p=0.022 income, OR=2.631, 95%: 1.386-6.231), gamma-glutamyltransferase (GGT) values >100mg/dl (p=0.035, OR=2.10, 95% CI: 1.345-5.850), and an ultrasound finding of biliary duct >8mm (p=0.034, OR=3.063 95% CI: 1086-8649). A score superior to 5 had a specificity and PPV of 100% for detecting choledocholithiasis and a score less than 3 had a sensitivity and NPV of 100% for excluding this diagnosis. The preoperative score can exclude or confirm the presence of choledocholithiasis and allows patients to directly benefit from laparoscopic cholecystectomy (LC) or prior endoscopic retrograde cholangiopancreatography (ERCP). Copyright © 2014 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.

  15. Liver Function Indicators Performed Better to Eliminate Cardioembolic Stroke than to Identify It from Stroke Subtypes.

    Science.gov (United States)

    Tan, Ge; Yuan, Ruozhen; Hao, Zilong; Lei, Chunyan; Xiong, Yao; Xu, Mangmang; Liu, Ming

    2017-01-01

    Identifying the etiology of ischemic stroke is essential to acute management and secondary prevention. The value of liver function indicators in differentiating stroke subtypes remains to be evaluated. A total of 1333 acute ischemic stroke patients were included. Liver function indicators collected within 24 hours from stroke onset, including alanine aminotransferase, aspartate aminotransferase (AST), alkaline phosphatase, gamma-glutamyl transpeptidase (GGT), and bilirubin (BILI), were collapsed into quartiles (Q) and also dichotomized by Q1. Multivariate regression analysis was conducted to identify the independent association between liver function indicators and cardioembolic stroke (SCE). Area under the curve (AUC) of receiver operating characteristic analysis was conducted, and sensitivity (Sen), specificity (Spe), positive prospective value (PPV), and negative prospective value (NPV) were determined to evaluate the predictive value of liver function indicators for SCE. AST, GGT, and BILI were associated with SCE. After adjustment, only AST was related to SCE independently. The incidence of SCE in the Q1 of AST, GGT, and BILI, particularly in the Q1 of AST, was quite low. The ability of AST, GGT, and BILI to identify SCE was poor, with low AUC, Sen, and PPV. The value of AST, GGT, and BILI in eliminating SCE from stroke subtypes was good, with high Spe and moderate NPV, and was enhanced after combining each liver function indicator. Results of present study demonstrated that AST, GGT, and BILI, particularly AST, had a potential to eliminate SCE from stroke subtypes, and the ability of eliminating SCE would be strengthened after combining each liver function indicator together. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  16. Sensitization predicts asthma development among wheezing toddlers in secondary healthcare.

    Science.gov (United States)

    Boersma, Nienke A; Meijneke, Ruud W H; Kelder, Johannes C; van der Ent, Cornelis K; Balemans, Walter A F

    2017-06-01

    Some wheezing toddlers develop asthma later in childhood. Sensitization is known to predict asthma in birth cohorts. However, its predictive value in secondary healthcare is uncertain. This study examines the predictive value of sensitization to inhalant allergens among wheezing toddlers in secondary healthcare for the development of asthma at school age (≥6 years). Preschool children (1-3 years) who presented with wheezing in secondary healthcare were screened on asthma at school age with the International Study of Asthma and Allergies in Childhood questionnaire. The positive and negative predictive value (PPV and NPV) of specific IgE to inhalant allergens (cut-off concentration 0.35 kU/L) and several non-invasive variables from a child's history (such as hospitalization, eczema, and parental atopy) were calculated. The additional predictive value of sensitization when combined with non-invasive predictors was examined in multivariate analysis and by ROC curves. Of 116 included children, 63% developed asthma at school age. Sensitization to inhalant allergens was a strong asthma predictor. The odds ratio (OR), PPV and NPV were 7.4%, 86%, and 55%, respectively. Eczema (OR 3.4) and hospital admission (OR 2.6) were significant non-invasive determinants. Adding sensitization to these non-invasive predictors in multivariate analysis resulted in a significantly better asthma prediction. The area under the ROC curve increased from 0.70 with only non-invasive predictors to 0.79 after adding sensitization. Sensitization to inhalant allergens is a strong predictor of school age asthma in secondary healthcare and has added predictive value when combined with non-invasive determinants. Pediatr Pulmonol. 2017;52:729-736. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. Influence of small-molecule material on performance of polymer solar cells based on MEH-PPV:PCBM blend

    International Nuclear Information System (INIS)

    Liu Xiao-Dong; Xu Zheng; Zhang Fu-Jun; Zhao Su-Ling; Zhang Tian-Hui; Gong Wei; Song Jing-Lu; Kong Chao; Yan Guang; Xu Xu-Rong

    2010-01-01

    In this work, the influence of a small-molecule material, tris(8-hydroxyquinoline) aluminum (Alq 3 ), on bulk heterojunction (BHJ) polymer solar cells (PSCs) is investigated in devices based on the blend of poly(2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene) (MEH-PPV) and [6,6]-phenyl-C 61 -butyric acid methyl ester (PCBM). By doping Alq 3 into MEH-PPV:PCBM solution, the number of MEH-PPV excitons can be effectively increased due to the energy transfer from Alq 3 to MEH-PPV, which probably induces the increase of photocurrent generated by excitons dissociation. However, the low carrier mobility of Alq 3 is detrimental to the efficient charge transport, thereby blocking the charge collection by the respective electrodes. The balance between photon absorption and charge transport in the active layer plays a key role in the performance of PSCs. For the case of 5 wt.% Alq 3 doping, the device performance is deteriorated rather than improved as compared with that of the undoped device. On the other hand, we adopt Alq 3 as a buffer layer instead of commonly used LiF. All the photovoltaic parameters are improved, yielding an 80% increase in power conversion efficiency (PCE) at the optimum thickness (1 nm) as compared with that of the device without any buffer layer. Even for the 5 wt.% Alq 3 doped device, the PCE has a slight enhancement compared with that of the standard device after modification with 1 nm (or 2 nm) thermally evaporated Alq 3 . The performance deterioration of Alq 3 -doped devices can be explained by the low solubility of Alq 3 , which probably deteriorates the bicontinuous D—A network morphology; while the performance improvement of the devices with Alq 3 as a buffer layer is attributed to the increased light harvesting, as well as blocking the hole leakage from MEH-PPV to the aluminum (Al) electrode due to the lower highest occupied molecular orbital (HOMO) level of Alq 3 compared with that of MEH-PPV

  18. Predictive Factors for Visual Field Conversion: Comparison of Scanning Laser Polarimetry and Optical Coherence Tomography.

    Science.gov (United States)

    Diekmann, Theresa; Schrems-Hoesl, Laura M; Mardin, Christian Y; Laemmer, Robert; Horn, Folkert K; Kruse, Friedrich E; Schrems, Wolfgang A

    2018-02-01

    The purpose of this study was to compare the ability of scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (SD-OCT) to predict future visual field conversion of subjects with ocular hypertension and early glaucoma. All patients were recruited from the Erlangen glaucoma registry and examined using standard automated perimetry, 24-hour intraocular pressure profile, and optic disc photography. Peripapillary retinal nerve fiber layer thickness (RNFL) measurements were obtained by SLP (GDx-VCC) and SD-OCT (Spectralis OCT). Positive and negative predictive values (PPV, NPV) were calculated for morphologic parameters of SLP and SD-OCT. Kaplan-Meier survival curves were plotted and log-rank tests were performed to compare the survival distributions. Contingency tables and Venn-diagrams were calculated to compare the predictive ability. The study included 207 patients-75 with ocular hypertension, 85 with early glaucoma, and 47 controls. Median follow-up was 4.5 years. A total of 29 patients (14.0%) developed visual field conversion during follow-up. SLP temporal-inferior RNFL [0.667; 95% confidence interval (CI), 0.281-0.935] and SD-OCT temporal-inferior RNFL (0.571; 95% CI, 0.317-0.802) achieved the highest PPV; nerve fiber indicator (0.923; 95% CI, 0.876-0.957) and SD-OCT mean (0.898; 95% CI, 0.847-0.937) achieved the highest NPV of all investigated parameters. The Kaplan-Meier curves confirmed significantly higher survival for subjects within normal limits of measurements of both devices (P<0.001). Venn diagrams tested with McNemar test statistics showed no significant difference for PPV (P=0.219) or NPV (P=0.678). Both GDx-VCC and SD-OCT demonstrate comparable results in predicting future visual field conversion if taking typical scans for GDx-VCC. In addition, the likelihood ratios suggest that GDx-VCC's nerve fiber indicator<30 may be the most useful parameter to confirm future nonconversion. (http://www.ClinicalTrials.gov number, NTC

  19. Clinical Usefulness of F-18 FDG PET/CT in papillary thyroid cancer with negative radioiodine scan and elevated thyroglobulin level or positive anti-thyroglobulin antibody

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Su Jung; Jung, Kyung Pyo; Lee, Sun Seong; Park, Yun Soo; Lee, Seok Mo [Dept. of Nuclear Medicine, Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of); Bae, Sang Kyun [Dept. of Nuclear Medicine, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2016-06-15

    Elevated thyroglobulin (Tg) levels, along with a negative radioiodine scan, present a clinical problem for the diagnosis of recurrence in papillary thyroid cancer (PTC) patients. The purpose of this study was to assess (1) the usefulness of 18F-fluorodeoxyglucose (F-18 FDG) positron emission tomography (PET)/computed tomography (CT) for PTC patients with negative diagnostic radioiodine scan and elevated serum Tg level or positive anti-thyroglobulin antibody (TgAb), and (2) the effect of endogenous thyroid stimulating hormone (TSH) stimulation (ETS) on detecting recurrence in these circumstances. Eighty-four patients with negative diagnostic radioiodine scan and elevated serum Tg or positive TgAb under ETS were included. Correlation with clinicopathological features and recurrence, detectability of FDG PET/CT and cut-off value of serum Tg for recurrence in PTC patients with these circumstance were assessed. In addition, detectability of F-18 FDG PET/CT under ETS and suppression were compared. In Cox regression analysis, only serum Tg level was significantly associated with recurrence (P<0.001, HR  = 1.13; 95 % CI, 1.061–1.208). The cut-off level of Tg was 21.5 ng/mL (AUC, 0.919; P < 0.001) for discriminating the recurrence in the patients with positive PET/CT finding. The sensitivity, specificity, PPV, NPV, and accuracy of F-18 FDG PET/CT for detecting recurrence were 64 %, 94 %, 86 %, 81 %, and 83 %. In the analysis of F-18 FDG PET/CT under ETS, the sensitivity, specificity, PPV, NPV and accuracy was 64 %, 94 %, 88 %, 81 % and 83 %. Those under TSH suppression were 67 %, 92 %, 80 %, 85 % and 83 %. F-18 FDG PET/CT, although less sensitive, showed high specificity, PPV, NPV, and accuracy and therefore can be useful for the patients with negative diagnostic radioiodine scan and elevated serum Tg or positive TgAb. In addition, FDG PET/CT under ETS does not seem to have an additive role in detecting recurrence in these patients.

  20. Pediatric FAST and elevated liver transaminases: An effective screening tool in blunt abdominal trauma.

    Science.gov (United States)

    Sola, Juan E; Cheung, Michael C; Yang, Relin; Koslow, Starr; Lanuti, Emma; Seaver, Chris; Neville, Holly L; Schulman, Carl I

    2009-11-01

    The current standard for the evaluation of children with blunt abdominal trauma (BAT) consists of physical examination, screening lab values, and computed tomography (CT) scan. We sought to determine if the focused assessment with sonography for trauma (FAST) combined with elevated liver transaminases (AST/ALT) could be used as a screening tool for intra-abdominal injury (IAI) in pediatric patients with BAT. Registry data at a level 1 trauma center was retrospectively reviewed from 1991-2007. Data collected on BAT patients under the age of 16 y included demographics, injury mechanism, ISS, GCS, imaging studies, serum ALT and AST levels, and disposition. AST and ALT were considered positive if either one was >100 IU/L. Overall, 3171 cases were identified. A total of 1008 (31.8%) patients received CT scan, 1148 (36.2%) had FAST, and 497 (15.7%) patients received both. Of the 497 patients, 400 (87.1%) also had AST and ALT measured. FAST was 50% sensitive, 91% specific, with a positive predictive value (PPV) of 68%, negative predictive value (NPV) of 83%, and accuracy of 80%. Combining FAST with elevated AST or ALT resulted in a statistically significant increase in all measures (sensitivity 88%, specificity 98%, PPV 94%, NPV 96%, accuracy 96%). FAST combined with AST or ALT > 100 IU/L is an effective screening tool for IAI in children following BAT. Pediatric patients with a negative FAST and liver transaminases < 100 IU/L should be observed rather than subjected to the radiation risk of CT.

  1. Usefulness of computed tomography in patients with right inferior abdominal quadrant pain: acute appendicitis and its alternative diagnosis

    International Nuclear Information System (INIS)

    Rossini, Sebastian A.; Haberman, Diego; Gonzalez Villaveiran, Ruben F.

    2009-01-01

    Purpose: To review the tomography findings of the acute appendicitis, their complications and alternative diagnosis. To value the use of helicoidal computed tomography (HCT) in the diagnosis of acute appendicitis and in the study of patients with right inferior abdominal quadrant (RIQ) pain and acute abdomen, for diagnosis and eventual complications, in order to decide treatment. Materials and method: For five months, the populations included in this retrospectively study were all patients delivered for presenting with RIQ pain for a HCT exam. These exams were made with oral and intravenous contrasts, when there were not contraindications. The HCT results were correlated with clinical follow up, surgery and histopathologic exams. Results: Over a total of 100 patients studied, 53 presented tomographic diagnosis of appendicitis, 22 of which presented perforation signs; 27 showed an alternative diagnosis (ovaries follicles, ureteral litiasis, tiphlitis, diverticulitis, colitis, salpingitis), 18 patients did not present tomographic findings to support the clinical symptoms and 2 presented indeterminated results. These data represented a sensibility of 100%, specificity of 95,7%, positive predictive value (PPV) of 96,2% and negative predictive value (NPV) of 100% for the tomography diagnosis of acute appendicitis and a sensibility of 100%, specificity of 81,8%, PPV of 95,1% and NPV of 100% for the tomography diagnosis of the different etiology in patient with right inferior acute abdomen. Conclusion: HCT is extremely useful in the study of patients with acute abdomen with origin in the RIQ, not only to make a diagnosis, but also to evaluate the complications, so as to decide proper treatment. (authors) [es

  2. An assessment of the usefulness of a rapid immuno-chromatographic test, "Determine™ malaria pf" in evaluation of intervention measures in forest villages of central India

    Directory of Open Access Journals (Sweden)

    Shukla Manmohan

    2001-08-01

    Full Text Available Abstract Background Plasmodium falciparum malaria, is a major health problem in forested tribal belt of central India. Rapid and accurate methods are needed for the diagnosis of P. falciparum. We performed a blinded evaluation of the recently introduced Determine™ malaria pf test (Abbott, Laboratories, Japan compared with microscopy and splenomegaly in children in epidemic prone areas of district Mandla to assess the impact of intervention measures. Methods Children aged 2–10 yrs with and without fever were examined for spleen enlargement by medical specialist by establishing a mobile field clinic. From these children thick blood smears were prepared from finger prick and read by a technician. Simultaneously, rapid tests were performed by a field lab attendant. The figures for specificity, sensitivity and predictive values were calculated using microscopy as gold standard. Results In all 349 children were examined. The sensitivity and specificity for Determine rapid diagnostic test were 91 and 80% respectively. The positive predictive values (PPV, negative predictive values (NPV and accuracy of the test were respectively 79, 91 and 85%. On the contrary, the sensitivity and specificity of spleen in detecting malaria infection were 57 and 74 % respectively with PPV of 73%, NPV 59 % and an accuracy of 65%. Conclusions Determine™ malaria rapid diagnostic test is easier and quicker to perform and has other advantages over microscopy in not requiring prior training of personnel or quality control. Thus, highlighting the usefulness of a rapid antigen test in assessing prevailing malaria situation in remote areas.

  3. Impact of the clinical context on the 14-3-3 test for the diagnosis of sporadic CJD

    Directory of Open Access Journals (Sweden)

    Sierra-Moros Maríajosé

    2006-07-01

    Full Text Available Abstract Background The 14-3-3 test appears to be a valuable aid for the clinical diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD in selected populations. However, its usefulness in routine practice has been challenged. In this study, the influence of the clinical context on the performance of the 14-3-3 test for the diagnosis of sCJD is investigated through the analysis of a large prospective clinical series. Methods Six hundred seventy-two Spanish patients with clinically suspected sCJD were analyzed. Clinical classification at sample reception according to the World Health Organization's (WHO criteria (excluding the 14-3-3 test result was used to explore the influence of the clinical context on the pre-test probabilities, and positive (PPV and negative (NPV predictive values of the 14-3-3 test. Results Predictive values of the test varied greatly according to the initial clinical classification: PPV of 98.8%, 96.5% and 45.0%, and NPV of 26.1%, 66.6% and 100% for probable sCJDi (n = 115, possible sCJDi (n = 73 and non-sCJDi (n = 484 cases, respectively. According to multivariate and Bayesian analyses, these values represent an improvement of diagnostic certainty compared to clinical data alone. Conclusion In three different contexts of sCJD suspicion, the 14-3-3 assay provides useful information complementary to clinical and electroencephalographic (EEG data. The test is most useful supporting a clinical impression, whilst it may show deceptive when it is not in agreement with clinical data.

  4. FDG-PET/CT at the end of immuno-chemotherapy in follicular lymphoma: the prognostic role of the ratio between target lesion and liver SUVmax (rPET).

    Science.gov (United States)

    Annunziata, Salvatore; Cuccaro, Annarosa; Tisi, Maria Chiara; Hohaus, Stefan; Rufini, Vittoria

    2018-06-01

    To retrospectively investigate the prognostic role of the ratio between target lesion and liver SUV max (rPET) in patients with follicular lymphoma (FL) submitted to FDG-PET/CT at the end of immuno-chemotherapy (PI-PET), and to compare rPET with International Harmonization Project criteria (IHP), Deauville Score (5p-DS) and FL International Prognostic Index at diagnosis (FLIPI). Eighty-nine patients with FL undergoing PI-PET were evaluated. The receiver operating characteristic (ROC) approach was applied to identify the optimal cut-point of rPET with respect to 5-years progression free survival (PFS). The prognostic significance of rPET was compared with IHP, DS and FLIPI. Positive predictive value (PPV) and negative predictive value (NPV) were calculated using the presence of adverse events as gold standard. The ROC analysis for rPET as predictor of progression showed an optimal rPET cut-point of 0.98. Patients with positive values of IHP, DS and rPET had a PFS of 50, 30 and 31%. PPV were of 56, 80 and 80%, NPV of 83, 86 and 88%, respectively. DS and rPET differed only in two patients. FLIPI was not predictive of progression and relapse. rPET is a prognostic factor in patients with FL submitted to PI-PET. Although it has a similar prognostic power as DS, it can have methodological advantages over visual analysis. PI-PET with different evaluation systems has a stronger prognostic power than FLIPI at diagnosis, so it could be useful to identify patients with FL at risk for early relapse after immuno-chemotherapy.

  5. Comparison of SPECT/CT and MRI in diagnosing symptomatic lesions in ankle and foot pain patients: diagnostic performance and relation to lesion type.

    Science.gov (United States)

    Ha, Seunggyun; Hong, Sung Hwan; Paeng, Jin Chul; Lee, Dong Yeon; Cheon, Gi Jeong; Arya, Amitabh; Chung, June-Key; Lee, Dong Soo; Kang, Keon Wook

    2015-01-01

    The purpose of this study was to compare the diagnostic performance of SPECT/CT and MRI in patients with ankle and foot pain, with regard to the lesion types. Fifty consecutive patients with ankle and foot pain, who underwent 99mTc-MDP SPECT/CT and MRI, were retrospectively enrolled in this study. Symptomatic lesions were determined based on clinical examination and response to treatment. On MRI and SPECT/CT, detected lesions were classified as bone, ligament/tendon, and joint lesions. Uptake on SPECT/CT was assessed using a 4-grade system. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SPECT/CT and MRI were evaluated in all detected lesions and each lesion type. Diagnostic value of uptake grade was analyzed using receiver-operating characteristics (ROC) curve analysis, and diagnostic performance was compared using Chi-square or McNemar tests. In overall lesions, the sensitivity, PPV and NPV of SPECT/CT for symptomatic lesions were 93%, 56%, 91%, and they were 98%, 48%, 95% for MRI. There was no significant difference between SPECT/CT and MRI. However, the specificity of SPECT/CT was significantly higher than that of MRI (48% versus 24%, P = 0.016). Uptake grade on SPECT/CT was significantly higher in symptomatic lesions (P diagnostic performance for symptomatic lesions in ankle and foot pain patients. SPECT/CT and MRI exhibit different diagnostic specificity in different lesion types. SPECT/CT may be used as a complementary imaging method to MRI for enhancing diagnostic specificity.

  6. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn’s Disease

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-01-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn’s disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-value<0.05 was considered as statistically significant. RESULTS Of the 30 patients with active CD, 11(36.7%) were men and 19 (63.3%) were women with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease. PMID:27252815

  7. Six rapid tests for direct detection of Clostridium difficile and its toxins in fecal samples compared with the fibroblast cytotoxicity assay.

    Science.gov (United States)

    Turgeon, David K; Novicki, Thomas J; Quick, John; Carlson, LaDonna; Miller, Pat; Ulness, Bruce; Cent, Anne; Ashley, Rhoda; Larson, Ann; Coyle, Marie; Limaye, Ajit P; Cookson, Brad T; Fritsche, Thomas R

    2003-02-01

    Clostridium difficile is one of the most frequent causes of nosocomial gastrointestinal disease. Risk factors include prior antibiotic therapy, bowel surgery, and the immunocompromised state. Direct fecal analysis for C. difficile toxin B by tissue culture cytotoxin B assay (CBA), while only 60 to 85% sensitive overall, is a common laboratory method. We have used 1,003 consecutive, nonduplicate fecal samples to compare six commercially available immunoassays (IA) for C. difficile detection with CBA: Prima System Clostridium difficile Tox A and VIDAS Clostridium difficile Tox A II, which detect C. difficile toxin A; Premier Cytoclone A/B and Techlab Clostridium difficile Tox A/B, which detect toxins A and B; and ImmunoCard Clostridium difficile and Triage Micro C. difficile panels, which detect toxin A and a species-specific antigen. For all tests, Triage antigen was most sensitive (89.1%; negative predictive value [NPV] = 98.7%) while ImmunoCard was most specific (99.7%; positive predictive value [PPV] = 95.0%). For toxin tests only, Prima System had the highest sensitivity (82.2%; NPV = 98.0%) while ImmunoCard had the highest specificity (99.7%; PPV = 95.0%). Hematopoietic stem cell transplant (HSCT) patients contributed 44.7% of all samples tested, and no significant differences in sensitivity or specificity were noted between HSCT and non-HSCT patients. IAs, while not as sensitive as direct fecal CBA, produce reasonable predictive values, especially when both antigen and toxin are detected. They also offer significant advantages over CBA in terms of turnaround time and ease of use.

  8. Validation of intensive care unit-acquired infection surveillance in the Italian SPIN-UTI network.

    Science.gov (United States)

    Masia, M D; Barchitta, M; Liperi, G; Cantù, A P; Alliata, E; Auxilia, F; Torregrossa, V; Mura, I; Agodi, A

    2010-10-01

    Validity is one of the most critical factors concerning surveillance of nosocomial infections (NIs). This article describes the first validation study of the Italian Nosocomial Infections Surveillance in Intensive Care Units (ICUs) project (SPIN-UTI) surveillance data. The objective was to validate infection data and thus to determine the sensitivity, specificity, and positive and negative predictive values of NI data reported on patients in the ICUs participating in the SPIN-UTI network. A validation study was performed at the end of the surveillance period. All medical records including all clinical and laboratory data were reviewed retrospectively by the trained physicians of the validation team and a positive predictive value (PPV), a negative predictive value (NPV), sensitivity and specificity were calculated. Eight ICUs (16.3%) were randomly chosen from all 49 SPIN-UTI ICUs for the validation study. In total, the validation team reviewed 832 patient charts (27.3% of the SPIN-UTI patients). The PPV was 83.5% and the NPV was 97.3%. The overall sensitivity was 82.3% and overall specificity was 97.2%. Over- and under-reporting of NIs were related to misinterpretation of the case definitions and deviations from the protocol despite previous training and instructions. The results of this study are useful to identify methodological problems within a surveillance system and have been used to plan retraining for surveillance personnel and to design and implement the second phase of the SPIN-UTI project. Copyright 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Thread sign in biliary intraductal papillary mucinous neoplasm: a novel specific finding for MRI

    International Nuclear Information System (INIS)

    Hong, Gil-Sun; Byun, Jae Ho; Kim, Jin Hee; Kim, Hyoung Jung; Lee, Seung Soo; Lee, Moon-Gyu; Hong, Seung-Mo

    2016-01-01

    To evaluate thread sign of biliary intraductal papillary mucinous neoplasm (B-IPMN) on magnetic resonance imaging (MRI). Thread sign was defined as intraductal linear or curvilinear hypointense striations. Two radiologists independently evaluated the presence and location of thread sign on MR cholangiography (thin-slice, thick-slab and 3D MRC) and axial MR images (T2 TSE, T2 HASTE and DWI) in patients with B-IPMN (n = 38) and in matched control groups with benign (n = 36) or malignant (n = 35) biliary diseases. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of thread sign for diagnosing B-IPMN were evaluated. Thread sign was observed only in patients with B-IPMN on MRC (44.7-52.6 % [17/38-20/38], P < 0.001) and axial MR images (31.6 % [12/38], P < 0.001), except in one patient with recurrent pyogenic cholangitis on MRC (2.8 %, 1/36). The sensitivity, specificity, accuracy, PPV and NPV of thread sign for diagnosing B-IPMN on MRC were 0.53, 0.99, 0.83, 0.95 and 0.80, respectively (reader 1) and 0.45, 1.0, 0.81, 1.0 and 0.77, respectively (reader 2). Thread sign was detected mainly at the extrahepatic bile duct (52.6 %, 20/38). B-IPMN can manifest thread sign, a novel specific MR finding, mainly at the extrahepatic bile duct on MRI, especially on MRC. (orig.)

  10. Effect of Metal Artifacts on Detection of Vertical Root Fractures Using Two Cone Beam Computed Tomography Systems.

    Science.gov (United States)

    Safi, Yaser; Aghdasi, Mohammad Mehdi; Ezoddini-Ardakani, Fatemeh; Beiraghi, Samira; Vasegh, Zahra

    2015-01-01

    Vertical root fracture (VRF) is common in endodontically treated teeth. Conventional and digital radiographies have limitations for detection of VRFs. Cone-beam computed tomography (CBCT) offers greater detection accuracy of VRFs in comparison with conventional radiography. This study compared the effects of metal artifacts on detection of VRFs by using two CBCT systems. Eighty extracted premolars were selected and sectioned at the level of the cemento enamel junction (CEJ). After preparation, root canals were filled with gutta-percha. Subsequently, two thirds of the root fillings were removed for post space preparation and a custom-made post was cemented into each canal. The teeth were randomly divided into two groups (n=40). In the test group, root fracture was created with Instron universal testing machine. The control teeth remained intact. CBCT scans of all teeth were obtained with either New Tom VGI or Soredex Scanora 3D. Three observers analyzed the images for detection of VRF. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for VRF detection and percentage of probable cases were calculated for each imaging system and compared using non-parametric tests considering the non-normal distribution of data. The inter-observer reproducibility was calculated using the weighted kappa coefficient. There were no statistically significant differences in sensitivity, specificity, PPV and NPV between the two CBCT systems. The effect of metal artifacts on VRF detection was not significantly different between the two CBCT systems.

  11. Rapid lung MRI in children with pulmonary infections: Time to change our diagnostic algorithms.

    Science.gov (United States)

    Sodhi, Kushaljit Singh; Khandelwal, Niranjan; Saxena, Akshay Kumar; Singh, Meenu; Agarwal, Ritesh; Bhatia, Anmol; Lee, Edward Y

    2016-05-01

    To determine the diagnostic utility of a new rapid MRI protocol, as compared with computed tomography (CT) for the detection of various pulmonary and mediastinal abnormalities in children with suspected pulmonary infections. Seventy-five children (age range of 5 to 15 years) with clinically suspected pulmonary infections were enrolled in this prospective study, which was approved by the institutional ethics committee. All patients underwent thoracic MRI (1.5T) and CT (64 detector) scan within 48 h of each other. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MRI were evaluated with CT as a standard of reference. Inter-observer agreement was measured with the kappa coefficient. MRI with a new rapid MRI protocol demonstrated sensitivity, specificity, PPV, and NPV of 100% for detecting pulmonary consolidation, nodules (>3 mm), cyst/cavity, hyperinflation, pleural effusion, and lymph nodes. The kappa-test showed almost perfect agreement between MRI and multidetector CT (MDCT) in detecting thoracic abnormalities (k = 0.9). No statistically significant difference was observed between MRI and MDCT for detecting thoracic abnormalities by the McNemar test (P = 0.125). Rapid lung MRI was found to be comparable to MDCT for detecting thoracic abnormalities in pediatric patients with clinically suspected pulmonary infections. It has a great potential as the first line cross-sectional imaging modality of choice in this patient population. However, further studies will be helpful for confirmation of our findings. © 2015 Wiley Periodicals, Inc.

  12. Follow-up of recurrences of limb soft tissue sarcomas in patients with localized disease: performance of ultrasound

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Truini, Mauro; Spina, Bruno; Cambiaso, Paolo; Zaottini, Federico; Bignotti, Bianca; Derchi, Lorenzo E.; Martinoli, Carlo; Calabrese, Massimo

    2015-01-01

    To evaluate diagnostic performance of ultrasound in the detection of local recurrences in patients with localized soft tissue sarcomas of the limb. An analysis of patients treated for soft tissue sarcomas between 2005 and April 2014 was performed. Sixty-eight patients (men/women, 36:32; age range, 18-84 years) were evaluated. Sensitivity, specificity with 95 % confidence intervals (CIs), positive predictive value (PPV), pre-test probability (the prevalence), negative predictive value (NPV), likelihood ratio for positive results (LH+), accuracy and post-test probability (post-P) of ultrasound were reported on a per patient basis using surgical findings and clinical follow-up as reference standard. Effects of independent variables (US equipment, age and sex, body mass index, radiologist) were considered. Comparison with MR was also performed. The overall sensitivity and specificity were 0.88 (0.60-0.94) and 0.94 (0.86-0.98). PPV, pre-test probability, NPV, LH+, accuracy and post-P: 0.83/0.25/0.96/14.9/0.92/0.83. There were two false negative cases both graded as G3 and deeply located and three false positive US cases. Diagnostic accuracy was not dependent by US machine (p = 0.08), age and sex (p = 0.16), body mass index (p = 0.07) and radiologists (p = 0.07). Diagnostic accuracy of ultrasound was relatively high. Negative US results excluded the presence of a local recurrence with acceptable accuracy. (orig.)

  13. Utility of intraoperative frozen sections in surgical decision making for acute invasive fungal rhinosinusitis.

    Science.gov (United States)

    Papagiannopoulos, Peter; Lin, Diana Murro; Al-Khudari, Samer; Rajan, Kumar; Reddy, Swathi; Gattuso, Paulo; Tajudeen, Bobby; Batra, Pete S

    2017-05-01

    Acute invasive fungal rhinosinusitis (AIFRS) represents a fulminant, potentially fatal, disease process in immunocompromised patients. The diagnosis often rests on high index of clinical suspicion, with relative paucity of data on the diagnostic and therapeutic implications of intraoperative frozen sections. Retrospective review was performed for 18 cases undergoing endoscopic sinus surgery for AIFRS. Reliability of intraoperative frozen section diagnosis was evaluated for all patients using final pathology as the gold standard. A total of 66 frozen sections were performed. Diagnostic accuracy of frozen sections illustrated sensitivity of 72.7% (95% confidence interval [CI], 0.57 to 0.85), specificity of 100% (95% CI, 0.85 to 1.00), positive predictive value (PPV) of 100% (95% CI, 0.89 to 1.00), and negative predictive value (NPV) of 64.7% (95% CI, 0.46 to 0.80). There was no statistically significant difference in sensitivity of frozen sections in cases of Mucor and Aspergillus at 68.8%% and 76.2%, respectively (p = 0.61). This study represents the largest series assessing the diagnostic accuracy of frozen section analysis in AIFRS. Frozen section analysis is an effective tool for guiding intraoperative decision making in patients with AIFRS with a high PPV. A Low NPV underscores the importance of clinical suspicion and intraoperative decision making based on endoscopic findings when negative frozen section results are encountered. Further, frozen section analysis appears to be equally effective in detecting either Mucor or Aspergillus. © 2017 ARS-AAOA, LLC.

  14. Feasibility and Field Performance of a Simultaneous Syphilis and HIV Point-of-Care Test Based Screening Strategy in at Risk Populations in Edmonton, Canada

    Directory of Open Access Journals (Sweden)

    Joshua Bergman

    2013-01-01

    Full Text Available Few studies have evaluated the feasibility of delivering syphilis point-of-care (POC testing in outreach (nonclinical settings in resource rich countries. The objectives of the study were to evaluate the feasibility and diagnostic performance of performing both HIV and syphilis POC testing in outreach settings and to document new cases identified in the study population. 1,265 outreach testing visits were offered syphilis and HIV POC testing and 81.5% (n=1,031 consented to testing. In our population, the SD Bioline 3.0 Syphilis Test had a sensitivity of 85.3% [CI (68.9–95.0], specificity of 100.0% [CI (99.6–100.0], positive predictive value (PPV of 100.0% [CI (88.1–100.0], and negative predictive value (NPV of 99.5% [CI (98.9–99.8]. Test characteristics for the INSTI HIV-1/HIV-2 Antibody Test had a 100.0% sensitivity [CI (39.8–100.00], 99.8 specificity [CI (99.3–100], 66.7% PPV [CI (22.3–95.7], and 100.0% NPV [CI (99.6–100.0]. Four new cases of syphilis and four new HIV cases were diagnosed. In summary, at risk population seeking STI testing found POC tests to be acceptable, the POC tests performed well in outreach settings, and new cases of syphilis and HIV were identified and linked to treatment and care.

  15. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    Science.gov (United States)

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  16. Quantifying forecast quality of IT business value

    NARCIS (Netherlands)

    Eveleens, J.L.; van der Pas, M.; Verhoef, C.

    2012-01-01

    This article discusses how to quantify the forecasting quality of IT business value. We address a common economic indicator often used to determine the business value of project proposals, the Net Present Value (NPV). To quantify the forecasting quality of IT business value, we develop a generalized

  17. Protonation of D-gluconate and its complexation with Np(V) in acidic to nearly neutral solutions

    International Nuclear Information System (INIS)

    Zhang, Z.; Clark, S.B.; Tian, G.; Rao, L.; Zanonato, P.L.

    2006-01-01

    Thermodynamic properties of the protonation of D-gluconic acid (HGH 4 (aq)) and its complexation with Np(V) have been studied in acidic to nearly neutral solutions at t = 25 C and I = 1 M NaClO 4 by potentiometry, spectrophotometry and calorimetry. The protonation constant (log K H ) and enthalpy (ΔH H ) of the carboxylate group are determined to be (3.30 ± 0.10) and -(4.03 ± 0.07) kJ mol -1 , respectively. Gluconate forms two Np(V) complexes in nearly neutral solutions. The formation constants and enthalpies of complexation are: log β 1 = (1.48 ± 0.03) and ΔH 1 = -(7.42 ± 0.13) kJ mol -1 for NpO 2 (GH 4 )(aq), log β = (2.14 ± 0.09) and ΔH 2 = -(12.08 ± 0.45) kJ mol -1 for NpO 2 (GH 4 ) 2 - . The thermodynamic parameters indicate that gluconic acid, like isosaccharinic acid and other α-hydroxycarboxylic acids, is a slightly stronger acid and forms stronger complexes with Np(V) than simple monocarboxylic acids. (orig.)

  18. Quantitative assessment of bone marrow attenuation values at MDCT: An objective tool for the detection of bone bruise related to occult sacral insufficiency fractures

    Energy Technology Data Exchange (ETDEWEB)

    Henes, F.O.; Groth, M.; Bley, T.A.; Regier, M.; Ittrich, H.; Adam, G.; Bannas, P. [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Nuechtern, J.V. [University Medical Center Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany); Treszl, A. [University Medical Center Hamburg-Eppendorf, Center for Experimental Medicine, Department of Medical Biometry and Epidemiology, Hamburg (Germany)

    2012-10-15

    To prove the feasibility of using Hounsfield attenuation values at MDCT to detect bone bruises related to sacral insufficiency fractures. Twenty-two patients with acute sacrum trauma and no fracture findings at MDCT were included in our prospective study. Two observers independently reviewed CTs regarding visual signs of bone bruises in 132 defined regions of the sacral alae. Interobserver agreement was tested by {kappa} statistics. Subsequently, HU values were obtained in the same regions, and attenuation differences between the two sides were calculated. Validity and reliability were assessed by intraclass correlation coefficient and Bland-Altman analysis. HU differences were subjected to ROC curve analysis to determine sensitivity, specificity, PPV and NPV. MRI served as standard reference. MRI revealed 19 regions with bone bruises and associated sacral insufficiency fractures. HU measurements demonstrated good validity and reliability (r = 0.989). ROC curve analysis exhibited an ideal cutoff value of 35.7 HU density difference between affected and non-affected regions. Visual evaluation revealed moderate agreement ({kappa} = 0.48); diagnostic accuracy was inferior to objective evaluation. Assessment of differences in bone marrow density by HU measurements is an objective and reliable tool for detection of bone bruises associated with occult sacral insufficiency fractures. (orig.)

  19. Sequential Objective Structured Clinical Examination based on item response theory in Iran

    Directory of Open Access Journals (Sweden)

    Sara Mortaz Hejri

    2017-09-01

    Full Text Available Purpose In a sequential objective structured clinical examination (OSCE, all students initially take a short screening OSCE. Examinees who pass are excused from further testing, but an additional OSCE is administered to the remaining examinees. Previous investigations of sequential OSCE were based on classical test theory. We aimed to design and evaluate screening OSCEs based on item response theory (IRT. Methods We carried out a retrospective observational study. At each station of a 10-station OSCE, the students’ performance was graded on a Likert-type scale. Since the data were polytomous, the difficulty parameters, discrimination parameters, and students’ ability were calculated using a graded response model. To design several screening OSCEs, we identified the 5 most difficult stations and the 5 most discriminative ones. For each test, 5, 4, or 3 stations were selected. Normal and stringent cut-scores were defined for each test. We compared the results of each of the 12 screening OSCEs to the main OSCE and calculated the positive and negative predictive values (PPV and NPV, as well as the exam cost. Results A total of 253 students (95.1% passed the main OSCE, while 72.6% to 94.4% of examinees passed the screening tests. The PPV values ranged from 0.98 to 1.00, and the NPV values ranged from 0.18 to 0.59. Two tests effectively predicted the results of the main exam, resulting in financial savings of 34% to 40%. Conclusion If stations with the highest IRT-based discrimination values and stringent cut-scores are utilized in the screening test, sequential OSCE can be an efficient and convenient way to conduct an OSCE.

  20. The role of multi-parametric MR imaging in the detection of early inflammatory sacroiliitis according to ASAS criteria

    Energy Technology Data Exchange (ETDEWEB)

    Boy, Fatma Nur, E-mail: nursoylu@yahoo.com [Department of Radiology, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Kayhan, Arda, E-mail: arda_kayhan@yahoo.com [Health Services Vocational School, Esenyurt University, Dogan Arasli Bulvari No 120, Esenyurt, Istanbul (Turkey); Karakas, Hakki Muammer, E-mail: hakki.karakas@gmail.com [Department of Radiology, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Unlu-Ozkan, Feyza, E-mail: feyzamd@yahoo.com [Department of Physical Therapy and Rehabilitation, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Silte, Duygu, E-mail: drduygusilte@hotmail.com [Department of Physical Therapy and Rehabilitation, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Aktas, İlknur, E-mail: iaktas@hotmail.com [Department of Physical Therapy and Rehabilitation, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey)

    2014-06-15

    Purpose: To retrospectively evaluate the accuracy of multi-parametric magnetic resonance (MR) imaging including fat saturated (FS) T2-weighted, short-tau inversion recovery (STIR), diffusion-weighted (DW-MR), and dynamic-contrast-enhanced MR (DCE-MR) imaging techniques in the diagnosis of early inflammatory sacroiliitis and determine the additional value of DW-MR and DCE-MR images according to recently defined ‘Assessment in SpondyloArthritis international Society’ criteria. Materials and methods: The study included 45 patients with back pain. Two radiologists estimated the likelihood of osteitis in 4 independent viewing sessions including FS T2-weighted, STIR, DW-MR and DCE-MR images. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic (ROC) curve (AUC) were calculated. Results: Of the 45 patients, 31 had inflammatory back pain. Of 31, 28 (90.3%) patients had inflammatory sacroiliitis diagnosed by clinical and laboratory analysis. FS T2-weighted MR images had the highest sensitivity (42.8% for both radiologists) for detecting osteitis in patients with inflammaory sacroiliitis when compared to other imaging sequences. For specificity, PPV, NPV, accuracy, and AUC levels there were no statistically significant difference between image viewing settings. However, adding STIR, DW-MR and DCE-MR images to the FS T2-weighted MR images did not improve the above stated indices. Conclusion: FS T2-weighted MR imaging had the highest sensitivity when compared to other imaging sequences. The addition of DW-MR and DCE-MR images did not significantly improve the diagnostic value of MR imaging in the diagnosis of osteitis for both experienced and less experienced radiologists.

  1. Sequential Objective Structured Clinical Examination based on item response theory in Iran.

    Science.gov (United States)

    Hejri, Sara Mortaz; Jalili, Mohammad

    2017-01-01

    In a sequential objective structured clinical examination (OSCE), all students initially take a short screening OSCE. Examinees who pass are excused from further testing, but an additional OSCE is administered to the remaining examinees. Previous investigations of sequential OSCE were based on classical test theory. We aimed to design and evaluate screening OSCEs based on item response theory (IRT). We carried out a retrospective observational study. At each station of a 10-station OSCE, the students' performance was graded on a Likert-type scale. Since the data were polytomous, the difficulty parameters, discrimination parameters, and students' ability were calculated using a graded response model. To design several screening OSCEs, we identified the 5 most difficult stations and the 5 most discriminative ones. For each test, 5, 4, or 3 stations were selected. Normal and stringent cut-scores were defined for each test. We compared the results of each of the 12 screening OSCEs to the main OSCE and calculated the positive and negative predictive values (PPV and NPV), as well as the exam cost. A total of 253 students (95.1%) passed the main OSCE, while 72.6% to 94.4% of examinees passed the screening tests. The PPV values ranged from 0.98 to 1.00, and the NPV values ranged from 0.18 to 0.59. Two tests effectively predicted the results of the main exam, resulting in financial savings of 34% to 40%. If stations with the highest IRT-based discrimination values and stringent cut-scores are utilized in the screening test, sequential OSCE can be an efficient and convenient way to conduct an OSCE.

  2. Predicting prolonged length of hospital stay in older emergency department users: use of a novel analysis method, the Artificial Neural Network.

    Science.gov (United States)

    Launay, C P; Rivière, H; Kabeshova, A; Beauchet, O

    2015-09-01

    To examine performance criteria (i.e., sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV], likelihood ratios [LR], area under receiver operating characteristic curve [AUROC]) of a 10-item brief geriatric assessment (BGA) for the prediction of prolonged length hospital stay (LHS) in older patients hospitalized in acute care wards after an emergency department (ED) visit, using artificial neural networks (ANNs); and to describe the contribution of each BGA item to the predictive accuracy using the AUROC value. A total of 993 geriatric ED users admitted to acute care wards were included in this prospective cohort study. Age >85years, gender male, polypharmacy, non use of formal and/or informal home-help services, history of falls, temporal disorientation, place of living, reasons and nature for ED admission, and use of psychoactive drugs composed the 10 items of BGA and were recorded at the ED admission. The prolonged LHS was defined as the top third of LHS. The ANNs were conducted using two feeds forward (multilayer perceptron [MLP] and modified MLP). The best performance was reported with the modified MLP involving the 10 items (sensitivity=62.7%; specificity=96.6%; PPV=87.1; NPV=87.5; positive LR=18.2; AUC=90.5). In this model, presence of chronic conditions had the highest contributions (51.3%) in AUROC value. The 10-item BGA appears to accurately predict prolonged LHS, using the ANN MLP method, showing the best criteria performance ever reported until now. Presence of chronic conditions was the main contributor for the predictive accuracy. Copyright © 2015 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  3. The role of multi-parametric MR imaging in the detection of early inflammatory sacroiliitis according to ASAS criteria

    International Nuclear Information System (INIS)

    Boy, Fatma Nur; Kayhan, Arda; Karakas, Hakki Muammer; Unlu-Ozkan, Feyza; Silte, Duygu; Aktas, İlknur

    2014-01-01

    Purpose: To retrospectively evaluate the accuracy of multi-parametric magnetic resonance (MR) imaging including fat saturated (FS) T2-weighted, short-tau inversion recovery (STIR), diffusion-weighted (DW-MR), and dynamic-contrast-enhanced MR (DCE-MR) imaging techniques in the diagnosis of early inflammatory sacroiliitis and determine the additional value of DW-MR and DCE-MR images according to recently defined ‘Assessment in SpondyloArthritis international Society’ criteria. Materials and methods: The study included 45 patients with back pain. Two radiologists estimated the likelihood of osteitis in 4 independent viewing sessions including FS T2-weighted, STIR, DW-MR and DCE-MR images. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic (ROC) curve (AUC) were calculated. Results: Of the 45 patients, 31 had inflammatory back pain. Of 31, 28 (90.3%) patients had inflammatory sacroiliitis diagnosed by clinical and laboratory analysis. FS T2-weighted MR images had the highest sensitivity (42.8% for both radiologists) for detecting osteitis in patients with inflammaory sacroiliitis when compared to other imaging sequences. For specificity, PPV, NPV, accuracy, and AUC levels there were no statistically significant difference between image viewing settings. However, adding STIR, DW-MR and DCE-MR images to the FS T2-weighted MR images did not improve the above stated indices. Conclusion: FS T2-weighted MR imaging had the highest sensitivity when compared to other imaging sequences. The addition of DW-MR and DCE-MR images did not significantly improve the diagnostic value of MR imaging in the diagnosis of osteitis for both experienced and less experienced radiologists

  4. Diagnostic value of 18F-FDG-PET/CT for the follow-up and restaging of soft tissue sarcomas in adults.

    Science.gov (United States)

    Kassem, T W; Abdelaziz, O; Emad-Eldin, S

    2017-10-01

    The purpose of this study was to evaluate the clinical utility of 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 FDG) positron emission tomography (PET)/computed tomography (CT) ( 18 F-FDG-PET/CT) in the follow-up of adult patients with soft tissue sarcomas. We prospectively evaluated 37 consecutive patients with known soft tissue sarcoma with 18 F-FDG-PET/CT examination for suspected recurrence of disease. They were 21 men and 16 women with a mean age of 49.6±10.6 (SD) years (range, 34-75years). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 18 F-FDG-PET/CT examination were calculated on a per patient basis. 18 F-FDG-PET/CT showed an overall diagnostic accuracy of 91.8%, sensitivity of 90% and a specificity of 100%. The positive predictive value and negative predictive value were 100 and 70%, respectively. The 18 F-FDG-PET/CT interpretations were correct in 34/37 patients (91.8%). Incorrect interpretations occurred in three patients (8.1%). Reasons for false negative findings were low 18 F-FDG uptake of local recurrence in one patient and low 18 F-FDG uptake of subcentimetric inguinal lymph node metastases. 18 F-FDG-PET/CT has a high diagnostic value in the follow-up of patients with soft tissue sarcoma. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  5. Sorption properties of bentonite clays towards Pu(IV), U(VI), Np(V) and Cs: experimental and surface complexation study

    Energy Technology Data Exchange (ETDEWEB)

    Sabodina, M.N. [Institute of Physical Chemistry of Russian Academy of Science, Moscow 119192 (Russian Federation); Kalmykov, St.N.; Sapozhnikov, Yu.A. [Radiochemistry div., Chemistry dept., Lomonosov Moscow State University, Moscow 119992, (Russian Federation); Gupalo, T.A.; Beigul, V.P. [VNIPI Promtechnology, Moscow (Russian Federation)

    2005-07-01

    Full text of publication follows: Sorption of radionuclides, their diffusion in bentonite as well as its solubility are the major factors that define bentonite as a geochemical barrier. Sorption of cations by bentonite could be governed by two mechanisms including ion exchange with interlayer cations and formation of surface complexes with either silanol or aluminol groups. The aim of this work was to study mechanisms of {sup 137}Cs, Pu(IV), Np(V) and U(VI) sorption by bentonite and their solubility in bentonite pore waters. Bentonite (Khakassiya deposit) used in the experiments was taken in Na-form and characterized by powder X-ray diffraction, scanning electron microscopy, potentiometric titration. The cation exchange capacities of bentonite at pH=6 were measured by isotopic exchange with {sup 22}Na{sup +} and Cs{sup +} saturation. Sorption experiments were performed in N{sub 2} atmosphere in plastic vials. Bentonite samples were left in the working solutions to swell for few days before sorption experiments were performed. After the desired concentration of radionuclide ({sup 137}Cs, {sup 238}Pu, {sup 239}Pu, {sup 237}Np, {sup 239}Np, {sup 238}U) was added to the suspension, the required pH values are established and samples were left until the equilibrium was reached. Separation of solution after the sorption was performed using micro- and ultrafiltration techniques. The sorption of Pu(IV), U(VI) and Np(V) was highly pH dependent that indicates predominant surface complexation mechanism of sorption. For {sup 137}Cs the pH dependence of sorption was less pronounced and significant decrease of sorption occurs at pH<1.7 that indicate the ion exchange as the major mechanism. The equilibrium constant of Na{sup +}/Cs{sup +} exchange was calculated form sorption isotherms and pH dependence of sorption. It is established using micro- and ultra-filtrations, that sorption of radionuclides onto bentonite nano colloids is essential. Surface complexation modeling exercises

  6. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kitao, Shinichiro; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago City, Tottori (Japan); Kaetsu, Yasuhiro [Kakogawa Higashi Hospital, Department of Cardiology, Kakogawa (Japan); Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro [Tottori University, Division of Cardiology, Department of Molecular Medicine and Therapeutics, Faculty of Medicine, Yonago (Japan)

    2017-07-15

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. (orig.)

  7. Studies on the Nucleotide Sequence, Transcription and Deletion Analysis of the BmNPV Protein Kinase Gene.

    Science.gov (United States)

    Zhang, Chuan-Xi; Hu, Cui; Wu, Xiang-Fu

    1998-01-01

    The coding region of BmvPK-1 gene of Bombyx mori NPV (Strain ZJ8) is 828 nt long and encodes a 276 aa polypeptide with predicted molecular mass of 32 kD. Dot blot analysis showed its mRNA to be gene is first detectable at 18 h p.i. and reaching the highest transcriptional level at 48 h p.i. The result suggested that BmvPK-1 gene is a late or very late gene. The most conserved 365 bp of the BmvPK-1 gene was deleted in a transfer vector (pUCPK-lac), and a report gene (lacZ) was inserted in the deleted position. Cotransfection of BmN cells with pUCPK-lac DNA and BmNPV DNA resulted in the recombinant virus which expressed detectable product of lacZ gene. But the virus with the deleted BmvPK-1 gene could not be isolated from the wild BmNPV by plaque purification method. The result showed that the BmvPK-1 gene deleted virus can multiply only with the help of the product of this gene from the wild type virus, and the gene is necessary for the virus to finish its life cycle in the cultured cells.

  8. Reduction of Pu(V) and Np(V) by leonardite humic acids and their quinonoid-enriched derivatives

    International Nuclear Information System (INIS)

    Shcherbina, N.S.; Kalmykov, St.N.; Perminova, I.V.; Kovalenko, A.N.

    2005-01-01

    Full text of publication follows: Humic substances (HS) are natural poly-electrolytes ubiquitous in aquatic environment responsible for complexation of metal ions. The presence of phenolic and quinonoid moieties in the structure of HS provide for their ability to take part in redox interactions. Capability of HS to reduce plutonium from higher oxidation states (Pu(V) and Pu(VI)) to tetravalent state was reported in several studies. However, the disparate results were reported for Np(V). The contradicting results on the redox behavior of HS could originate from the structural differences of the humic materials tested, in particular, from varying content of the redox-active quinonoid moieties. To test this hypothesis, the goal of this research was to evaluate reducing performance of leonardite humic acids and of their quinonoid-enriched derivatives with respect to Pu(V) and Np(V). The quinonoid-enriched humic derivatives were obtained using the reaction of formaldehyde co-poly-condensation between parent humic material - leonardite humic acid - and model dihydroxybenzenes - hydroquinone, catechol and 1,4-benzoquinone. The humic material: quinonoid monomer ration of 1 g per 250 mg was used. The reduction of Np(V) was studied at micro- and macro-concentration level: 10 -7 M and 10 -4 M, respectively. In case of Pu(V) the concentration was about 10 -10 M. The HS concentrations varied from 1 to 100 ppm, while ionic strength was zero. All experiments were conducted in anaerobic conditions and in the darkness. The kinetics of Pu(V) reduction was studied using solvent extraction (TTA in toluene); to monitor Np(V) reduction two independent techniques were used: solvent extraction and VIS-NIR spectrophotometry. The latter allows measuring absorbance of NpO 2 + and Np-humate complexes at 981.3 and 987.4 nm, respectively. Fast reduction of Pu(V) by the parent humic material was observed and the reduction rate increased with a decrease in pH. In case of Np(V), there was no

  9. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Ming; Zhang, Qilin [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Wang, Meng [Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Soochow University, Division of Endocrinology, the Second Affiliated Hospital, Suzhou (China); Zhu, Jingjing [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Neuropathology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Yao, Zhenwei [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Radiology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Lu, Yun [Fudan University, Department of Nuclear Medicine, Huashan Hospital, Shanghai Medical College, Shanghai (China)

    2016-11-15

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  10. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    International Nuclear Information System (INIS)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei; Yao, Zhenwei; Lu, Yun

    2016-01-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  11. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly.

    Science.gov (United States)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yao, Zhenwei; Lu, Yun; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Yang, Yeping; Zhao, Yao; Wang, Yongfei

    2016-11-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly.

  12. NPV risk simulation of an open pit gold mine project under the O'Hara cost model by using GAs

    Institute of Scientific and Technical Information of China (English)

    Franco-Sepulveda Giovanni; Campuzano Carlos; Pineda Cindy

    2017-01-01

    This paper analyzes an open pit gold mine project based on the O'Hara cost model. Hypothetical data is proposed based on different authors that have studied open pit gold projects, and variations are proposed according to the probability distributions associated to key variables affecting the NPV, like production level, ore grade, price of ore, and others, so as to see what if, in a gold open pit mine project of 3000 metric tons per day of ore. Two case scenarios were analyzed to simulate the NPV, one where there is low certainty data available, and the other where the information available is of high certainty. Results based on genetic algorithm metaheuristic simulations, which combine basically Montecarlo simulations provided by the Palisade Risk software, the O'Hara cost model, net smelter return and financial analysis tools offered by Excel are reported, in order to determine to which variables of the project is more sensitive the NPV.

  13. Facile Synthesis of Well-Defined MDMO-PPV Containing (TriBlock—Copolymers via Controlled Radical Polymerization and CuAAC Conjugation

    Directory of Open Access Journals (Sweden)

    Neomy Zaquen

    2015-02-01

    Full Text Available A systematic investigation into the chain transfer polymerization of the so-called radical precursor polymerization of poly(p-phenylene vinylene (PPV materials is presented. Polymerizations are characterized by systematic variation of chain transfer agent (CTA concentration and reaction temperature. For the chain transfer constant, a negative activation energy of −12.8 kJ·mol−1 was deduced. Good control over molecular weight is achieved for both the sulfinyl and the dithiocarbamate route (DTC. PPVs with molecular weights ranging from thousands to ten thousands g·mol−1 were obtained. To allow for a meaningful analysis of the CTA influence, Mark–Houwink–Kuhn–Sakurada (MHKS parameters were determined for conjugated MDMO-PPV ([2-methoxy-5-(3',7'-dimethyloctyloxy]-1,4-phenylenevinylene to α = 0.809 and k = 0.00002 mL·g−1. Further, high-endgroup fidelity of the CBr4-derived PPVs was proven via chain extension experiments. MDMO-PPV-Br was successfully used as macroinitiator in atom transfer radical polymerization (ATRP with acrylates and styrene. A more polar PPV counterpart was chain extended by an acrylate in single-electron transfer living radical polymerization (SET-LRP. In a last step, copper-catalyzed azide alkyne cycloaddition (CuAAC was used to synthesize block copolymer structures. Direct azidation followed by macromolecular conjugation showed only partial success, while the successive chain extension via ATRP followed by CuAAC afforded triblock copolymers of the poly(p-phenylene vinylene-block-poly(tert-butyl acrylate-block-poly(ethylene glycol (PPV-b-PtBuA-b-PEG.

  14. Malignancy Risk Assessment in Patients with Thyroid Nodules Using Classification and Regression Trees

    Directory of Open Access Journals (Sweden)

    Shokouh Taghipour Zahir

    2013-01-01

    Full Text Available Purpose. We sought to investigate the utility of classification and regression trees (CART classifier to differentiate benign from malignant nodules in patients referred for thyroid surgery. Methods. Clinical and demographic data of 271 patients referred to the Sadoughi Hospital during 2006–2011 were collected. In a two-step approach, a CART classifier was employed to differentiate patients with a high versus low risk of thyroid malignancy. The first step served as the screening procedure and was tailored to produce as few false negatives as possible. The second step identified those with the lowest risk of malignancy, chosen from a high risk population. Sensitivity, specificity, positive and negative predictive values (PPV and NPV of the optimal tree were calculated. Results. In the first step, age, sex, and nodule size contributed to the optimal tree. Ultrasonographic features were employed in the second step with hypoechogenicity and/or microcalcifications yielding the highest discriminatory ability. The combined tree produced a sensitivity and specificity of 80.0% (95% CI: 29.9–98.9 and 94.1% (95% CI: 78.9–99.0, respectively. NPV and PPV were 66.7% (41.1–85.6 and 97.0% (82.5–99.8, respectively. Conclusion. CART classifier reliably identifies patients with a low risk of malignancy who can avoid unnecessary surgery.

  15. Low-dose computed tomography for lung cancer screening: comparison of performance between annual and biennial screen

    Energy Technology Data Exchange (ETDEWEB)

    Sverzellati, Nicola; Silva, M. [University of Parma, Radiology, Department of Surgical Sciences, Parma (Italy); Calareso, G.; Marchiano, A. [Fondazione IRCCS Istituto Nazionale dei Tumori, Department of Radiology, Milan (Italy); Galeone, C. [University of Milano-Bicocca, Department of Statistics and Quantitative Methods, Division of Biostatistics, Epidemiology and Public Health, Laboratory of Healthcare Research and Pharmacoepidemiology, Milan (Italy); Sestini, S.; Pastorino, U. [Fondazione IRCCS Istituto Nazionale dei Tumori, Department of Surgery, Section of Thoracic Surgery, Milan (Italy); Sozzi, G. [Fondazione IRCCS Istituto Nazionale dei Tumori, Tumor Genomics Unit, Department of Experimental Oncology and Molecular Medicine, Milan (Italy)

    2016-11-15

    To compare the performance metrics of two different strategies of lung cancer screening by low-dose computed tomography (LDCT), namely, annual (LDCT1) or biennial (LDCT2) screen. Recall rate, detection rate, interval cancers, sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively) were compared between LDCT1 and LDCT2 arms of the MILD trial over the first seven (T0-T6; median follow-up 7.3 years) and four rounds (T0-T3; median follow-up 7.3 years), respectively. 1152 LDCT1 and 1151 LDCT2 participants underwent a total of 6893 and 4715 LDCT scans, respectively. The overall recall rate was higher in LDCT2 arm (6.97 %) than in LDCT1 arm (5.81 %) (p = 0.01), which was counterbalanced by the overall lower number of LDCT scans. No difference was observed for the overall detection rate (0.56 % in both arms). The two LDCT arms had similar specificity (99.2 % in both arms), sensitivity (73.5 %, in LDCT2 vs. 68.5 % in LDCT1, p = 0.62), PPV (42.4 %, in LDCT2, vs. 40.6 %, in LDCT1, p = 0.83) and NPV (99.8 %, in LDCT2 vs. 99.7 %, in LDCT1, p = 0.71). Biennial screen may save about one third of LDCT scans with similar performance indicators as compared to annual screening. (orig.)

  16. Low-dose computed tomography for lung cancer screening: comparison of performance between annual and biennial screen

    International Nuclear Information System (INIS)

    Sverzellati, Nicola; Silva, M.; Calareso, G.; Marchiano, A.; Galeone, C.; Sestini, S.; Pastorino, U.; Sozzi, G.

    2016-01-01

    To compare the performance metrics of two different strategies of lung cancer screening by low-dose computed tomography (LDCT), namely, annual (LDCT1) or biennial (LDCT2) screen. Recall rate, detection rate, interval cancers, sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively) were compared between LDCT1 and LDCT2 arms of the MILD trial over the first seven (T0-T6; median follow-up 7.3 years) and four rounds (T0-T3; median follow-up 7.3 years), respectively. 1152 LDCT1 and 1151 LDCT2 participants underwent a total of 6893 and 4715 LDCT scans, respectively. The overall recall rate was higher in LDCT2 arm (6.97 %) than in LDCT1 arm (5.81 %) (p = 0.01), which was counterbalanced by the overall lower number of LDCT scans. No difference was observed for the overall detection rate (0.56 % in both arms). The two LDCT arms had similar specificity (99.2 % in both arms), sensitivity (73.5 %, in LDCT2 vs. 68.5 % in LDCT1, p = 0.62), PPV (42.4 %, in LDCT2, vs. 40.6 %, in LDCT1, p = 0.83) and NPV (99.8 %, in LDCT2 vs. 99.7 %, in LDCT1, p = 0.71). Biennial screen may save about one third of LDCT scans with similar performance indicators as compared to annual screening. (orig.)

  17. Validation of an Arab names algorithm in the determination of Arab ancestry for use in health research

    Science.gov (United States)

    El-Sayed, Abdulrahman M.; Lauderdale, Diane S.; Galea, Sandro

    2010-01-01

    Objective Data about Arab-Americans, a growing ethnic minority, is not routinely collected in vital statistics, registry, or administrative data in the US. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically-based, probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. Design We used data from all Michigan birth certificates between 2000-2005. Fathers’ surnames and mothers’ maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Results State-wide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and a NPV of 98.6%. Both the false positive and false negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false positive rate increased and false-negative rate decreased. Conclusion The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA. PMID:20845117

  18. Systematic review of flexion/extension radiography of the cervical spine in trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Sierink, J.C., E-mail: j.c.sierink@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Lieshout, W.A.M. van, E-mail: w.a.vanlieshout@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Beenen, L.F.M., E-mail: l.f.beenen@amc.nl [Department of Radiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Schep, N.W.L., E-mail: n.w.schep@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Vandertop, W.P., E-mail: w.p.vandertop@amc.nl [Neurosurgical Center Amsterdam, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Goslings, J.C., E-mail: j.c.goslings@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2013-06-15

    Introduction: The aim of this review was to investigate whether Flexion/Extension (F/E) radiography adds diagnostic value to CT or MRI in the detection of cervical spine ligamentous injury and/or clinically significant cervical spine instability of blunt trauma patients. Methods: A systematic search of literature was done in Pubmed, Embase and Cochrane Library databases. Primary outcome was sensitivity and specificity of F/E radiography. Secondary outcomes were the positive predicting value (PPV) and negative predicting value (NPV) (with CT or MRI as reference tests due to the heterogeneity of the included studies) of each modality and the quality of F/E radiography. Results: F/E radiography was overall regarded to be inferior to CT or MRI in the detection of ligamentous injury. This was reflected by the high specificity and NPV for CT with F/E as reference test (ranging from 97 to 100% and 99 to 100% respectively) and the ambiguous results for F/E radiography with MRI as its reference test (0–98% and 0–83% for specificity and NPV respectively). Image quality of F/E radiography was reported to have 31 to 70% adequacy, except in two studies which reported an adequacy of respectively 4 and 97%. Conclusion: This systematic review of the literature shows that F/E radiography adds little diagnostic value to the evaluation of blunt trauma patients compared to CT and MRI, especially in those cases where CT or MRI show no indication of ligamentous injury.

  19. Systematic review of flexion/extension radiography of the cervical spine in trauma patients

    International Nuclear Information System (INIS)

    Sierink, J.C.; Lieshout, W.A.M. van; Beenen, L.F.M.; Schep, N.W.L.; Vandertop, W.P.; Goslings, J.C.

    2013-01-01

    Introduction: The aim of this review was to investigate whether Flexion/Extension (F/E) radiography adds diagnostic value to CT or MRI in the detection of cervical spine ligamentous injury and/or clinically significant cervical spine instability of blunt trauma patients. Methods: A systematic search of literature was done in Pubmed, Embase and Cochrane Library databases. Primary outcome was sensitivity and specificity of F/E radiography. Secondary outcomes were the positive predicting value (PPV) and negative predicting value (NPV) (with CT or MRI as reference tests due to the heterogeneity of the included studies) of each modality and the quality of F/E radiography. Results: F/E radiography was overall regarded to be inferior to CT or MRI in the detection of ligamentous injury. This was reflected by the high specificity and NPV for CT with F/E as reference test (ranging from 97 to 100% and 99 to 100% respectively) and the ambiguous results for F/E radiography with MRI as its reference test (0–98% and 0–83% for specificity and NPV respectively). Image quality of F/E radiography was reported to have 31 to 70% adequacy, except in two studies which reported an adequacy of respectively 4 and 97%. Conclusion: This systematic review of the literature shows that F/E radiography adds little diagnostic value to the evaluation of blunt trauma patients compared to CT and MRI, especially in those cases where CT or MRI show no indication of ligamentous injury

  20. Laboratory and Field Studies of Poly(2,5-bis(N-methyl-N-hexylaminophenylene vinylene (BAM-PPV: A Potential Wash Primer Replacement for Army Military Vehicles

    Directory of Open Access Journals (Sweden)

    Peter Zarras

    2014-09-01

    Full Text Available In this study, an electroactive polymer (EAP, poly(2,5-bis(N-methyl-N- hexylaminophenylene vinylene (BAM-PPV, was tested as an alternative to current hexavalent chromium (Cr(VI-based Army wash primers. BAM-PPV was tested in both laboratory and field studies to determine its adhesive and corrosion-inhibiting properties when applied to steel and aluminum alloys. The Army Research Laboratory (ARL tests showed that BAM-PPV combined with an epoxy primer and the Army chemical agent-resistant coating (CARC topcoat met Army performance requirements for military coatings. After successful laboratory testing, the BAM-PPV was then field tested for one year at the Aberdeen Test Center (ATC. This field testing showed that BAM-PPV incorporated into the Army military coating survived with no delamination of the coating and only minor corrosion on the chip sites.

  1. Role of Combined Post-Operative Venous Lactate and 48 Hours C-Reactive Protein Values on the Etiology and Predictive Capacity of Organ-Space Surgical Site Infection after Elective Colorectal Operation.

    Science.gov (United States)

    Juvany, Montserrat; Guirao, Xavier; Oliva, Joan Carles; Badía Pérez, Jose M

    2017-04-01

    C-reactive protein (CRP) has been assessed to detect organ-space surgical site infection (OSI). Nevertheless, data about peri-operative oxygen debt and surgical stress-elicited biologic markers to explain and allow for the early detection of OSI are lacking. We analyzed immediate post-operative venous lactate, early CRP levels, and intra-operative hemodynamic values on the capacity to predict OSI after elective colorectal operation. Patients undergoing an elective colorectal surgical procedure with anastomosis between March 2013 and August 2014 were included and assessed prospectively. Post-operative lactate values at L-0, L-6, and L-24 hours, CRP (basal and 48 h), and the percentage of operative time (POT) with systolic blood pressure below 100 mm Hg and heart rate above 90 beats per minute in patients with and without OSI were compared. Binary logistic regression was constructed for L-0 and CRP-48, and receiver-operating characteristic (ROC) was analyzed for sensitivity (S), specificity (Sp), positive (PPV) and negative (NPV) predictive values. Patients with OSI (11 of 100) showed higher L-0 and L-24 (3.2 ± 2.5 vs. 1.6 ± 0.8; p = 0.025 and 1.9 ± 1.2 vs. 1.2 ± 0.4 mmol/L; p = 0.025) and CRP-48 (188 ± 80 vs. 74 ± 52 mg/L; p = 0.001). The ROC from logistic regression showed area under the curve of 0.899 (95% confidence interval [CI] 0.805-0.992), S of 72% (95% CI 43.2%-90.5%), Sp of 95% (95% CI 88.6%-98.4%), PPV of 66% (95% CI 38.9%-86.4%) and NPV of 0.96 (95% CI 90%-99%). L-0 was higher in those patients with hypotension during more than 60% of the POT (2.4 ± 2.1 vs. 1.6 ± 0.8; p = 0.038). Patients with OSI had a higher POT with hypotension (50 ± 28% vs. 30 ± 28%; p = 0.032) and tachycardia (18 ± 27% vs. 5 ± 16%; p = 0,024). The combination of immediate post-operative lactate and CRP at 48 hours proved to be useful in predicting OSI after elective colorectal operation

  2. Rectosigmoid endometriosis: Comparison between CT water enema and video laparoscopy

    International Nuclear Information System (INIS)

    Stabile Ianora, A.A.; Moschetta, M.; Lorusso, F.; Lattarulo, S.; Telegrafo, M.; Rella, L.; Scardapane, A.

    2013-01-01

    Aim: To evaluate the accuracy of water enema computed tomography (CT) for predicting the location of endometriosis in patients with contraindications to magnetic resonance imaging (MRI), focusing on rectosigmoid lesions and having laparoscopic and histological data as the reference standard. Materials and methods: Thirty-three women (mean age 33.4 ± 3.1 years) suspected of having deep pelvic endometriosis underwent 64-row CT and video laparoscopy within 4 weeks. Two radiologists blinded to the clinical data evaluated the CT images obtained after colonic retrograde distension using water as the contrast medium, and a comparison with laparoscopic and histological findings was performed. CT sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. The radiation dose to patients was estimated. Cohen's weighted kappa (κ) test was used to evaluate the interobserver agreement. Results: In 23 out of 33 patients (69%) intestinal implants were found at surgery and pathological examinations. CT confirmed the diagnosis of rectosigmoid endometriosis in 20 out of 23 implants. Three nodules located on the proximal sigmoid colon (two serosal lesions and one infiltrating the muscularis layer) with a diameter of less than 1 cm were not diagnosed. CT sensitivity, specificity, PPV, NPV, and accuracy values were 87, 100, 100, 77, and 91%, respectively. The mean effective dose estimate was 6.30 ± 1.7 mSv. Almost perfect agreement between the two readers was found (k = 0.84). Conclusion: Water enema CT can play a role in the diagnosis of bowel endometriosis and represents another accurate potential tool for video laparoscopic approaches, especially in patients for whom MRI is contraindicated

  3. Stress perfusion magnetic resonance imaging to detect coronary artery lesions in children.

    Science.gov (United States)

    Vijarnsorn, Chodchanok; Noga, Michelle; Schantz, Daryl; Pepelassis, Dion; Tham, Edythe B

    2017-05-01

    Stress perfusion cardiovascular magnetic resonance (CMR) is used widely in adult ischemic heart disease, but data in children is limited. We sought to evaluate feasibility, accuracy and prognostic value of stress CMR in children with suspected coronary artery disease (CAD). Stress CMR was reviewed from two pediatric centers over 5 years using a standard pharmacologic protocol. Wall motion abnormalities, perfusion deficits and late enhancement were correlated with coronary angiogram (CAG) when available, and clinical status at 1 year follow-up for major adverse cardiovascular events (MACE; coronary revascularization, non-fatal myocardial infarction and death due to CAD) was recorded. Sixty-four stress perfusion CMR studies in 48 children (10.9 ± 4.8 years) using adenosine; 59 (92%) and dipyridamole; 5 (8%), were reviewed. Indications were Kawasaki disease (39%), post arterial switch operation (12.5%), post heart transplantation (12.5%), post anomalous coronary artery repair (11%), chest pain (11%), suspected myocarditis or CAD (3%), post coronary revascularization (3%), and others (8%). Twenty-six studies were performed under sedation. Of all studies performed, 66% showed no evidence of ischemia or infarction, 28% had perfusion deficits and 6% had late gadolinium enhancement (LGE) without perfusion deficit. Compared to CAG, the positive predictive value (PPV) of stress CMR was 80% with negative predictive value (NPV) of 88%. At 1 year clinical follow-up, the PPV and NPV of stress CMR to predict MACE were 78 and 98%. Stress-perfusion CMR, in combination with LGE and wall motion-analysis is a feasible and an accurate method of diagnosing CAD in children. In difficult cases, it also helps guide clinical intervention by complementing conventional CAG with functional information.

  4. Initial clinical results of simultaneous {sup 18}F-FDG PET/MRI in comparison to {sup 18}F-FDG PET/CT in patients with head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kubiessa, K.; Gawlitza, M.; Kuehn, A.; Fuchs, J.; Kahn, T.; Stumpp, P. [University Hospital of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Purz, S.; Steinhoff, K.G.; Sabri, O.; Kluge, R. [University Hospital of Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Boehm, A. [University Hospital of Leipzig, ENT Department, Leipzig (Germany)

    2014-04-15

    The aim of this study was to evaluate the diagnostic capability of simultaneous {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/MRI compared to {sup 18}F-FDG PET/CT as well as their single components in head and neck cancer patients. In a prospective study 17 patients underwent {sup 18}F-FDG PET/CT for staging or follow-up and an additional {sup 18}F-FDG PET/MRI scan with whole-body imaging and dedicated examination of the neck. MRI, CT and PET images as well as PET/MRI and PET/CT examinations were evaluated independently and in a blinded fashion by two reader groups. Results were compared with the reference standard (final diagnosis determined in consensus using all available data including histology and follow-up). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. A total of 23 malignant tumours were found with the reference standard. PET/CT showed a sensitivity of 82.7 %, a specificity of 87.3 %, a PPV of 73.2 % and a NPV of 92.4 %. Corresponding values for PET/MRI were 80.5, 88.2, 75.6 and 92.5 %. No statistically significant difference in diagnostic capability could be found between PET/CT and PET/MRI. Evaluation of the PET part from PET/CT revealed highest sensitivity of 95.7 %, and MRI showed best specificity of 96.4 %. There was a high inter-rater agreement in all modalities (Cohen's kappa 0.61-0.82). PET/MRI of patients with head and neck cancer yielded good diagnostic capability, similar to PET/CT. Further studies on larger cohorts to prove these first results seem justified. (orig.)

  5. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  6. Advanced radiological work-up as an adjunct to decision in early reconstructive surgery in brachial plexus injuries

    Directory of Open Access Journals (Sweden)

    Björkman Anders

    2010-07-01

    Full Text Available Abstract Background As neurophysiologic tests may not reveal the extent of brachial plexus injury at the early stage, the role of early radiological work-up has become increasingly important. The aim of the study was to evaluate the concordance between the radiological and clinical findings with the intraoperative findings in adult patients with brachial plexus injuries. Methods Seven consecutive male patients (median age 33; range 15-61 with brachial plexus injuries, caused by motor cycle accidents in 5/7 patients, who underwent extensive radiological work-up with magnetic resonance imaging (MRI, computed tomography myelography (CT-M or both were included in this retrospective study. A total of 34 spinal nerve roots were evaluated by neuroradiologists at two different occasions. The degree of agreement between the radiological findings of every individual nerve root and the intraoperative findings was estimated by calculation of kappa coefficient (К-value. Using the operative findings as a gold standard, the accuracy, sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of the clinical findings and the radiological findings were estimated. Results The diagnostic accuracy of radiological findings was 88% compared with 65% for the clinical findings. The concordance between the radiological findings and the intraoperative findings was substantial (К = 0.76 compared with only fair (К = 0.34 for the clinical findings. There were two false positive and two false negative radiological findings (sensitivity and PPV of 0.90; specificity and NPV of 0.87. Conclusions The advanced optimized radiological work-up used showed high reliability and substantial agreement with the intraoperative findings in adult patients with brachial plexus injury.

  7. Relative volume measured with magnetic resonance imaging is an articular collapse predictor in hematological pediatric patients with femoral head osteonecrosis.

    Science.gov (United States)

    Ippolito, Davide; Masetto, Alessandro; Talei Franzesi, Cammillo; Bonaffini, Pietro A; Casiraghi, Alessandra; Sironi, Sandro

    2016-08-28

    To assess the potential value of femoral head (FH) volume measurements to predict joint collapse, as compared to articular surface involvement, in post-treatment osteonecrosis (ON) in pediatric patients affected by lymphoproliferative diseases. Considering 114 young patients with lymphoproliferative diseases undergone a lower-limbs magnetic resonance imaging (MRI) examination between November 2006 and August 2012 for a suspected post-treatment ON, we finally considered a total of 13 cases (7 males, mean age 15.2 ± 4.8 years), which developed a FH ON lesions (n = 23). The MRI protocol included coronal short tau inversion recovery and T1-weighted sequences, from the hips to the ankles. During the follow-up (elapsed time: 9.2 ± 2 mo), 13/23 FH articular surface (FHS) developed articular deformity. The first MRI studies with diagnosis of ON were retrospectively analyzed, measuring FH volume (FHV), FHS, ON volume (ONV) and the articular surface involved by ON (ONS). The relative involvement of FHS, in terms of volume [relative volume (RV): ONV/FHV] and articular surface [relative surface (RS): ONS/FHS], was then calculated. By using receiver operating characteristic curve analysis (threshold of 23% of volume involvement), RV predicted articular deformity in 13/13 FHS [sensitivity 100%, specificity 90%, accuracy 95%, positive predictive value (PPV) 93%, negative predictive value (NPV) 100%]. Considering a threshold of 50% of articular involvement, RS predicted articular deformity in 10/13 femoral heads (sensitivity 77%, specificity 100%, accuracy 87%, PPV 100%, NPV 77%). RV might be a more reliable parameter than RS in predicting FH deformity and could represent a potential complementary diagnostic tool in the follow-up of femoral heads ON lesions.

  8. Diagnostic approach to urinary tract infections in male general practice patients: a national surveillance study

    Science.gov (United States)

    den Heijer, Casper DJ; van Dongen, Martien CJM; Donker, Gé A; Stobberingh, Ellen E

    2012-01-01

    Background Diagnostic urinary tract infection (UTI) studies have primarily been performed among female patients. Aim To create a diagnostic algorithm for male general practice patients suspected of UTI. Design and setting Surveillance study in the Dutch Sentinel General Practice Network. Method Clinical information and dipstick results were collected from 603 patients. Algorithm-predicted care was compared with care as usual in terms of sensitivity (antibiotic recommended when UTI was confirmed) and specificity (no antibiotic recommended when no UTI was observed). Results Complete information was available from 490/603 (81%) males, of whom 66% (321/490) had a UTI. A diagnostic algorithm recommending antimicrobial prescription in the case of a positive nitrite test or a positive leukocyte esterase test in males aged ≥60 years, had a positive predictive value (PPV) of 83% (95% confidence interval [CI] = 78 to 87) and a negative predictive value (NPV) of 60% (95% CI = 52 to 66), respectively (area under the ROC curve: 0.78, 95% CI = 0.74 to 0.82). When both dipstick results were positive in males aged ≥60 years, PPV increased to 90% (95% CI = 83 to 94), whereas NPV was highest in males Sensitivity and specificity of predicted UTI care and usual care did not differ (75% versus 79%, P = 0.30, and 70% versus 63%, P = 0.17, respectively). Conclusion UTI care provided to Dutch male GP patients is as accurate as predicted care from a diagnostic algorithm. The studied clinical information and dipstick tests are useful for ruling in UTI in males, but have limited value in ruling out this diagnosis. PMID:23211182

  9. Lipid Accumulation Product (LAP) and Visceral Adiposity Index (VAI) as Markers of Insulin Resistance and Metabolic Associated Disturbances in Young Argentine Women with Polycystic Ovary Syndrome.

    Science.gov (United States)

    Abruzzese, Giselle A; Cerrrone, Gloria E; Gamez, Juan M; Graffigna, Mabel N; Belli, Susana; Lioy, Gustavo; Mormandi, Eduardo; Otero, Patricia; Levalle, Oscar A; Motta, Alicia B

    2017-01-01

    Polycystic ovary syndrome (PCOS) is an endocrine disorder. PCOS women are at high risk of developing insulin resistance (IR) and cardiovascular disorders since young age. We aimed to study the reliability of lipid accumulation product (LAP) and visceral adiposity index (VAI) as markers of metabolic disturbances (MD) associated with IR in young reproductive aged PCOS patients. We also evaluated the association between LAP and VAI and the presence of hyperandrogenism. In a cross-sectional study, 110 PCOS patients and 88 control women (18-35 years old) were recruited. PCOS patients were divided into 2 groups, as hyperandrogenic and non-hyperandrogenic considering the signs of hyperandrogenism (clinical or biochemical). Anthropometric measurements were taken and blood samples collected. Metabolic and anthropometric characteristics and their association with IR and associated MD were evaluated and LAP and VAI were calculated. LAP and VAI were compared with TC/HDL-c and TG/HDL-c to define the best markers of MD in this population. Independently of the phenotype, young PCOS patients showed high IR and dyslipidemia. Both LAP and VAI showed to be more effective markers to assess MD and IR in these young women than TG/HDL-c or TC/HDL-c [cut-off values: LAP: 18.24 (sensitivity: 81.43% specificity: 73.49%), positive predictive value (PPV): 75.0%, negative predictive value (NPV): 77.27%, VAI: 2.19 (sensitivity: 81.16% specificity: 72.15% PPV: 74.65% NPV: 72.22%)]. LAP and VAI are representative markers to assess MD associated with IR in young PCOS patients. All PCOS patients, independently of their androgenic condition, showed high metabolic risk. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Diffusion-Weighted Magnetic Resonance Diagnosis of Local Recurrences of Prostate Cancer after Radical Prostatectomy: Preliminary Evaluation on Twenty-Seven Cases

    Directory of Open Access Journals (Sweden)

    Salvatore Francesco Carbone

    2014-01-01

    Full Text Available Objectives. To assess the diagnostic performance of diffusion-weighted MR imaging (DWI in patients affected by prostatic fossa (PF relapse after radical prostatectomy (RP for prostatic carcinoma (PC. Methods. Twenty-seven patients showing a nodular lesion in the PF at T2-weighted MR imaging after RP, with diagnosis of PC relapse established by biopsy or PSA determinations, were investigated by DWI. Two readers evaluated the DWI results in consensus and the apparent diffusion coefficient (ADC of the nodules, separately; a mean value was obtained (ADCm. Results. Relapses did not significantly differ in size in respect of postsurgical benign nodules. The DWI qualitative evaluation showed sensitivity, specificity, accuracy, ppv, and npv values, respectively, of 83.3%, 88.9%, 85.2%, 93.7%, and 72.7% (100%, 87.5%, 95.6%, 93.7%, and 100%, for nodules >6 mm. The intraclass correlation coefficient (ICC for ADC evaluation between the two readers was 0.852 (95% CI 0.661–0.935; P=0.0001. The ADCm values for relapses and benign nodules were, respectively, 0.98±0.21×10−3 mm2/sec and 1.24±0.32×10−3 mm2/sec (P=0.006. Sensitivity, specificity, accuracy, ppv and npv of ADCm were, respectively, 77.8%, 88.9%, 81.8%, 93.3%, and 66.7% (93.3%, 87.5%, 85.4%, 93.3%, and 87.5% for nodules >6 mm. Conclusions. Diffusion-weighted MR imaging is a promising tool in the management of a hyperintense nodule detected by T2-weighted sequences. This might have a relevant importance in contouring radiotherapy treatment volumes.

  11. Clinical performance of a new point-of-care cardiac troponin I test.

    Science.gov (United States)

    Christ, Michael; Geier, Felicitas; Blaschke, Sabine; Giannitsis, Evangelos; Khellaf, Mehdi; Mair, Johannes; Pariente, David; Scharnhorst, Volkher; Semjonow, Veronique; Hausfater, Pierre

    2018-04-09

    We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR-) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.

  12. Ratio of ovarian stroma and total ovarian area by ultrasound in prediction of hyperandrogenemia in reproductive-aged Thai women with polycystic ovary syndrome: a diagnostic test.

    Science.gov (United States)

    Leerasiri, Pichai; Wongwananuruk, Thanyarat; Rattanachaiyanont, Manee; Indhavivadhana, Suchada; Techatraisak, Kitirat; Angsuwathana, Surasak

    2015-02-01

    To evaluate the performance of ovarian stromal area to total ovarian area (S/A) ratio for the prediction of biochemical hyperandrogenism in Thai women with polycystic ovary syndrome (PCOS). A cross-sectional study was performed in 222 reproductive-aged Thai women with PCOS attending the Gynecologic Endocrinology Unit (GEU), Department of Obstetrics and Gynecology, Faculty of Medicine Siriraj Hospital from May 2007 to January 2009. The patients were interviewed for medical history and examined for anthropometry and clinical hyperandrogenism. Venous blood samples were obtained for androgen profiles. An ovarian ultrasonogram was obtained via transvaginal or transrectal ultrasonography. The prevalences of clinical and biochemical hyperandrogenism were 48.6% and 81.1%, respectively. The S/A ratio at a cut-off point of 0.33 had modest predictability for hyperandrogenism, namely, 0.537 area under the receiver-operator curve, 36.6% sensitivity, 72.1% specificity, 83.8% positive predictive value (PPV) and 20.9% negative predictive value (NPV). The combination of clinical hyperandrogenism and S/A ratio improved the predictability for biochemical hyperandrogenism, with sensitivity, specificity, PPV and NPV of 72.1%, 58.1%, 87.8% and 33.3%, respectively. The S/A ratio alone is not a good predictor for biochemical hyperandrogenism in Thai PCOS women attending GEU for menstrual dysfunction. The combination of S/A ratio and clinical hyperandrogenism has better performance than the S/A ratio alone to predict biochemical hyperandrogenism. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  13. A single institution experience with the new bethesda system for reporting thyroid cytopathology: correlation with existing cytologic, clinical, and histological data.

    Science.gov (United States)

    McElroy, Michele K; Mahooti, Sepi; Hasteh, Farnaz

    2014-07-01

    Our goal was to evaluate the Bethesda system (TBS) in comparison to the previously used system at our institution. One hundred consecutive thyroid fine needle aspirations (FNAs) and 45 consecutive indeterminate FNAs were reviewed by two cytopathology-boarded pathologists, diagnosed based on TBS and correlated with management and follow-up. Re-evaluation led to a diagnosis change in 48% of cases. Thirty-nine percent of benign cases were unsatisfactory under TBS. For malignant diagnoses the positive predictive value (PPV) was unchanged, while the negative predictive value (NPV) was slightly improved using TBS. Both the PPV and NPV were improved for actionable diagnoses. Inter-observer variability across all categories was in moderate agreement. Clinical management of both follicular lesion (FL) and indeterminate cases ranged from none to immediate surgery. Repeat FNA resolved the diagnosis in 50% of indeterminate cases. Indeterminate cases had an overall malignancy rate of 27%; higher in pre- (46%) than post-TBS cases (8%). Inter-observer variability between the reviewing pathologists and the original pathologists for indeterminate cases was fair, and between the two reviewing pathologists was moderate. Using TBS criteria increased the unsatisfactory rate and led to improved prediction of malignancy and actionable diagnoses. The pre-Bethesda diagnosis of FL at our institution led to inconsistent clinical management. Clinical management of patients with indeterminate diagnoses was essentially unchanged following adoption of TBS. The moderate inter-observer agreement between the reviewing pathologists may be related to level of cytology experience, strict adherence to TBS, and the exclusive use of cytomorphology for diagnosis. © 2014 Wiley Periodicals, Inc.

  14. B-type natriuretic peptide as a marker for heart failure in patients with acute stroke.

    Science.gov (United States)

    Koenig, Matthew A; Puttgen, H Adrian; Prabhakaran, Vivek; Reich, Daniel; Stevens, Robert D

    2007-09-01

    To determine whether serum N-terminal pro-B-type natriuretic peptide (N-BNP), a biomarker of myocardial wall stress, is specific to acute heart failure (HF) in patients hospitalized with stroke. Case-control study. Tertiary hospital, Neurosciences Critical Care Unit and Stroke Unit. Consecutive patients with acute ischemic or hemorrhagic stroke who were evaluated for HF. None. Cases and controls were classified, respectively, as patients with or without HF, defined according to modified Framingham criteria. Seventy-two patients were evaluated, 39 with ischemic stroke, 22 with aneurysmal subarachnoid hemorrhage (SAH), and 11 with intracerebral hemorrhage (ICH). Thirty-four patients (47%) met criteria for HF, and 47 patients (65%) had systolic or diastolic left ventricular (LV) dysfunction on echocardiogram. Serum N-BNP was measured a median of 48 h following the onset of stroke and was increased (> 900 pg/ml) in 56 patients (78%), with higher levels in non-survivors (11898 +/- 12741 vs 4073 +/-5691; p = 0.001). In a multiple regression model, N-BNP elevation was not independently associated with HF (OR 5.4, 95% CI 0.8-36.0, p = 0.084). At a cut-off of 900 pg/ml, the sensitivity of N-BNP for HF was 94%, specificity 37%, positive predictive value (PPV) 57%, and negative predictive value (NPV) 88%. For systolic or diastolic LV dysfunction, the sensitivity of N-BNP was 89%, specificity 44%, PPV 75%, and NPV 69%. These results demonstrate that N-BNP elevation is not specific to HF or LV dysfunction in patients with acute ischemic stroke, SAH, and ICH.

  15. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  16. MRI of placenta percreta: differentiation from other entities of placental adhesive disorder.

    Science.gov (United States)

    Thiravit, Shanigarn; Lapatikarn, Sukanya; Muangsomboon, Kobkun; Suvannarerg, Voraparee; Thiravit, Phakphoom; Korpraphong, Pornpim

    2017-01-01

    To retrospectively review the MRI findings of placenta percreta and identify those helpful for differentiation from non-placenta percreta. The MRI images of 21 patients with a preliminary diagnosis of placental adhesive disorder scanned between 2005 and 2014 were evaluated. Radiologists blinded to the final diagnosis evaluated six previously described MRI findings of placenta adhesive disorder. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predictive value (PPV) of MRI for the diagnosis of placenta percreta were also calculated. The study included 12 cases of placenta percreta and 9 cases of non-placenta percreta. Invasion of placental tissue outside the uterus was found only in placenta percreta (p = 0.045; sensitivity 41.7 %; specificity 100 %). All placenta percreta cases also had a moderate to marked degree of heterogeneous placental signal intensity (p = 0.063; sensitivity 100 %; specificity 33.3 %). The size of the dark bands on T2-weighted imaging, and the presence of disorganized intra-placental vessels, showed no statistically significant difference between placenta percreta and non-placenta percreta. The sensitivity, specificity, NPV, PPV, and accuracy of MRI for detection of placenta percreta were 91.7, 44, 80, 68, and 71.4 %, respectively. MRI is recommended for the evaluation of placenta percreta, with the most specific signs including the invasion of placental tissue outside the uterus on B-FFE sequences, and consideration of the degree of placental signal heterogeneity. The size of the T2 dark band alone, or bizarre disorganized intra-placental vessels, did not correlate with the severity of invasion.

  17. Biochemical verification of the self-reported smoking status of screened male smokers of the Dutch-Belgian randomized controlled lung cancer screening trial.

    Science.gov (United States)

    van der Aalst, Carlijn M; de Koning, Harry J

    2016-04-01

    Smoking is the main cause of lung cancer, so data linked to smoking behaviour are important in lung cancer screening trials. However, self-reporting data concerning smoking behaviour are mainly used. The aim of this study was to biochemically determine the validity and reliability of self-reported smoking status among smokers at high risk for developing lung cancer participating in the Dutch-Belgian lung cancer screening (NELSON) trial. For this sub study, a random sample of 475 men was selected who were scheduled for the fourth screening round in the NELSON trial. They were asked to complete a short questionnaire to verify the smoking behaviour for the previous seven days and a blood sample was collected to measure the cotinine level. The validity (sensitivity (Se), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV)) and reliability (Kappa) of the self-reported smoking status compared to the cotinine level (as golden standard) were determined. Both a completed questionnaire as well as a cotinine level were available for 199 (41.9%) participants. Based on these data, Se and Sp were respectively 98% (95%-Confidence Interval (CI): 91-99) and 98% (95%-CI: 93-100). PPV and NPV were 98% and 96% and Kappa was 0.96. In conclusion, the validity of the self-reported smoking status turned out to be reliable amongst men at high risk for developing lung cancer who participate in the NELSON lung cancer screening trial. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Comparative analysis of four commercial on-farm culture methods to identify bacteria associated with clinical mastitis in dairy cattle.

    Science.gov (United States)

    Ferreira, Jair C; Gomes, Marilia S; Bonsaglia, Erika C R; Canisso, Igor F; Garrett, Edgar F; Stewart, Jamie L; Zhou, Ziyao; Lima, Fabio S

    2018-01-01

    Several multiple-media culture systems have become commercially available for on-farm identification of mastitis-associated pathogens. However, the accuracy of these systems has not been thoroughly and independently validated against microbiological evaluations performed by referral laboratories. Therefore, the purpose of the present study was to evaluate the performance of commercially available culture plates (Accumast, Minnesota Easy System, SSGN and SSGNC Quad plates) to identify pathogens associated with clinical mastitis in dairy cows. Milk samples from the affected quarter with clinical mastitis were aerobically cultured with the on-farm culture systems and by two additional reference laboratories. Agreeing results from both standard laboratories were denoted as the reference standard (RS). Accuracy (Ac), sensitivity (Se), specificity (Sp), positive and negative predictive values (PPV and NPV, respectively) and Cohen's kappa coefficient (k) of on-farm plates were determined based on the RS culture of 211 milk samples. All four plate-systems correctly identified ≥ 84.9% of milk samples with no bacterial growth. Accumast had greater values for all overall predictive factors (Ac, Se, Sp, PPV and NPV) and a substantial agreement (k = 0.79) with RS. The inter-rater agreements of Minnesota, SSGN, and SSGNC with RS were moderate (0.45 ≤ k ≤ 0.55). The effectiveness to categorize bacterial colonies at the genus and species was numerically different amongst the commercial plates. Our findings suggest that Accumast was the most accurate on-farm culture system for identification of mastitis-associated pathogens of the four systems included in the analysis.

  19. Artificial neural networks: Predicting head CT findings in elderly patients presenting with minor head injury after a fall.

    Science.gov (United States)

    Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L

    2017-02-01

    To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Building and Validating a Computerized Algorithm for Surveillance of Ventilator-Associated Events.

    Science.gov (United States)

    Mann, Tal; Ellsworth, Joseph; Huda, Najia; Neelakanta, Anupama; Chevalier, Thomas; Sims, Kristin L; Dhar, Sorabh; Robinson, Mary E; Kaye, Keith S

    2015-09-01

    To develop an automated method for ventilator-associated condition (VAC) surveillance and to compare its accuracy and efficiency with manual VAC surveillance The intensive care units (ICUs) of 4 hospitals This study was conducted at Detroit Medical Center, a tertiary care center in metropolitan Detroit. A total of 128 ICU beds in 4 acute care hospitals were included during the study period from August to October 2013. The automated VAC algorithm was implemented and utilized for 1 month by all study hospitals. Simultaneous manual VAC surveillance was conducted by 2 infection preventionists and 1 infection control fellow who were blinded to each another's findings and to the automated VAC algorithm results. The VACs identified by the 2 surveillance processes were compared. During the study period, 110 patients from all the included hospitals were mechanically ventilated and were evaluated for VAC for a total of 992 mechanical ventilation days. The automated VAC algorithm identified 39 VACs with sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 100%. In comparison, the combined efforts of the IPs and the infection control fellow detected 58.9% of VACs, with 59% sensitivity, 99% specificity, 91% PPV, and 92% NPV. Moreover, the automated VAC algorithm was extremely efficient, requiring only 1 minute to detect VACs over a 1-month period, compared to 60.7 minutes using manual surveillance. The automated VAC algorithm is efficient and accurate and is ready to be used routinely for VAC surveillance. Furthermore, its implementation can optimize the sensitivity and specificity of VAC identification.

  1. Role of CT/PET in predicting nodal disease in head and neck cancers

    International Nuclear Information System (INIS)

    Singham, S.; Iyer, G.; Clark, J.

    2009-01-01

    Full text:Introduction: Pre-treatment evaluation of the presence of cervical nodal metastases is important in head and neck cancers and has major prognostic implications. In this study, we aim to determine the accuracy of CT/PET as a tool for identifying such metastases. Methods: All patients from Royal Prince Alfred and Liverpool Hospitals, who underwent CT/PET for any cancer arising from the head and neck, and who underwent subsequent surgery (which included a neck dissection) within 8 weeks of the CT/PET were included. Nodal staging was undertaken by utilising imaging-based nodal classification, and comparison with pathologic data from the surgical specimen was made. PET was considered positive if the SUV was greater than 2. Results: We identified 111 patients from the above criteria. 80 of such patients were treated for squamous cell carcinoma (SCC). CT/PET identified unsuspected metastatic disease in 6 patients. Correlation of CT/PET findings and the presence of disease at the primary site: sensitivity: 98%, specificity: 93%, positive predictive value (PPV): 98% and negative predictive value (NPV): 93%. Correlating CT/PET findings with the presence of nodal disease at any level: sensitivity: 95%, specificity: 88%, PPV: 95% and NPV: 88%. CT/PET was anatomically accurate in predicting the site of metastases in 62/74 (84%). Conclusion: PET is accurate in predicting both presence of nodal metastases and the level of involvement. CT/PET should be undertaken as a pre-operative tool to assist in planning the extent of surgery required in head and neck cancers.

  2. Comparison of Diagnostic Algorithms for Detecting Toxigenic Clostridium difficile in Routine Practice at a Tertiary Referral Hospital in Korea.

    Science.gov (United States)

    Moon, Hee-Won; Kim, Hyeong Nyeon; Hur, Mina; Shim, Hee Sook; Kim, Heejung; Yun, Yeo-Min

    2016-01-01

    Since every single test has some limitations for detecting toxigenic Clostridium difficile, multistep algorithms are recommended. This study aimed to compare the current, representative diagnostic algorithms for detecting toxigenic C. difficile, using VIDAS C. difficile toxin A&B (toxin ELFA), VIDAS C. difficile GDH (GDH ELFA, bioMérieux, Marcy-l'Etoile, France), and Xpert C. difficile (Cepheid, Sunnyvale, California, USA). In 271 consecutive stool samples, toxigenic culture, toxin ELFA, GDH ELFA, and Xpert C. difficile were performed. We simulated two algorithms: screening by GDH ELFA and confirmation by Xpert C. difficile (GDH + Xpert) and combined algorithm of GDH ELFA, toxin ELFA, and Xpert C. difficile (GDH + Toxin + Xpert). The performance of each assay and algorithm was assessed. The agreement of Xpert C. difficile and two algorithms (GDH + Xpert and GDH+ Toxin + Xpert) with toxigenic culture were strong (Kappa, 0.848, 0.857, and 0.868, respectively). The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of algorithms (GDH + Xpert and GDH + Toxin + Xpert) were 96.7%, 95.8%, 85.0%, 98.1%, and 94.5%, 95.8%, 82.3%, 98.5%, respectively. There were no significant differences between Xpert C. difficile and two algorithms in sensitivity, specificity, PPV and NPV. The performances of both algorithms for detecting toxigenic C. difficile were comparable to that of Xpert C. difficile. Either algorithm would be useful in clinical laboratories and can be optimized in the diagnostic workflow of C. difficile depending on costs, test volume, and clinical needs.

  3. Self-diagnosis of active head lice infestation by individuals from an impoverished community: high sensitivity and specificity Auto diagnóstico de pediculose por indivíduos de uma comunidade economicamente desfavorecida: alta sensibilidade e especificidade

    Directory of Open Access Journals (Sweden)

    Daniel Pilger

    2008-04-01

    Full Text Available To compare sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis; we performed visual inspection and thereafter wet combing (gold standard. Of the 175 individuals included, 77 (44% had an active head lice infestation. For self-diagnosis, sensitivity (80.5%, specificity (91.8%, PPV (88.6% and NPV (85.7% were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.Foi conduzido um estudo em uma favela urbana no Brasil com o objetivo de comparar a sensibilidade, especificidade, valor preditivo positivo (VPP e valor preditivo negativo (VPN do auto-diagnóstico de pediculose com a inspeção visual. Dos 175 indivíduos incluídos, 77 (44% apresentavam pediculose. Para o auto-diagnóstico, a sensibilidade (80.5%, a especificidade (91.8%, o VPP (88.6% e o VPN (85.7% foram altos. A sensibilidade da inspeção visual foi 35.1%. Profissionais de saúde podem utilizar o auto-diagnóstico como uma ferramenta diagnóstica para estimar de forma acurada a prevalência de pediculose em uma comunidade, como também para monitorar estratégias de controle da doença.

  4. Young Mania Rating Scale: how to interpret the numbers? Determination of a severity threshold and of the minimal clinically significant difference in the EMBLEM cohort.

    Science.gov (United States)

    Lukasiewicz, Michael; Gerard, Stephanie; Besnard, Adeline; Falissard, Bruno; Perrin, Elena; Sapin, Helene; Tohen, Mauricio; Reed, Catherine; Azorin, Jean-Michel

    2013-03-01

    The aim of this analysis was to identify Young Mania Rating Scale (YMRS) meaningful benchmarks for clinicians (severity threshold, minimal clinically significant difference [MCSD]) using the Clinical Global Impressions Bipolar (CGI-BP) mania scale, to provide a clinical perspective to randomized clinical trials (RCTs) results. We used the cohort of patients with acute manic/mixed state of bipolar disorders (N = 3459) included in the European Mania in Bipolar Longitudinal Evaluation of Medication (EMBLEM) study. A receiver-operating characteristic analysis was performed on randomly selected patients to determine the YMRS optimal severity threshold with CGI-BP mania score ≥ "Markedly ill" defining severity. The MCSD (clinically meaningful change in score relative to one point difference in CGI-BP mania for outcome measures) of YMRS, was assessed with a linear regression on baseline data. At baseline, YMRS mean score was 26.4 (±9.9), CGI-BP mania mean score was 4.8 (±1.0) and 61.7% of patients had a score ≥ 5. The optimal YMRS severity threshold of 25 (positive predictive value [PPV] = 83.0%; negative predictive value [NPV] = 66.0%) was determined. In this cohort, a YMRS score of 20 (typical cutoff for RCTs inclusion criteria) corresponds to a PPV of 74.6% and to a NPV of 77.6%, meaning that the majority of patients included would be classified as severely ill. The YMRS minimal clinically significant difference was 6.6 points. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Evaluation of field recognizable morbidity indicators of Schistosoma haematobium infection among primary school children in Ghana

    Directory of Open Access Journals (Sweden)

    Ato Kwamena Tetteh

    2016-09-01

    Materials and Methods — In all, 417 pupils in three primary schools (Kasseh sub-District, Dangme East District, Ghana, provided urine samples, which were examined for S. haematobium ova. The study utilized a structured questionnaire, the Urit 10V multi-stick urine reagent strips and the filtration method. Results — Overall, prevalence by microscopy was 20.9% (requires targeted treatment once every two years, and was higher (14.0% among the 10-15 years age group (χ2=22.44, p<0.001. The lowest prevalence was among the <6 (0.5%, 2/417 and ≥19 (1.4%, 6/417 years age groups. There was no significant difference in prevalence among females (7.9%, 33/417 and males (12.9%, 54/417 (χ2=2.58, p=0.108. Self-reported haematuria was 43.2% (targeted treatment once a year. There was a significant difference between female (16.1%, 67/417 and male (27.1%, 113/417 responses to self-reported haematuria (χ2=4.170, p<0.001. A lower consolidated mean prevalence of 11.7% was estimated among pupils who had ova in their urine and also exhibited three morbidity indicators (haematuria, leucocyturia and proteinuria. Combined and averaged sensitivity and specificity estimations (sensitivity = 55.4%, specificity = 67.8%, Positive Predictive Value (PPV = 53.4%, Negative Predictive Value (NPV = 64.2% of these morbidity indicators, was insufficient in equalizing the reliability of ova quantification. With the exception of leucocyturia, which was common among all pupils, 28.75% (25/87 of the infected individuals did not have any form of haematuria or proteinuria. Out of these, one pupil had heavy ova intensity (80 eggs/10ml of urine while the remaining 24 had low ova intensity infection (1-44 eggs/10ml of urine. Questionnaire correctly identified 56.3% of pupils with S. haematobium ova in their urine, also reporting bloody urine (PPV=27.2%; NPV=84.0%. It also identified 49.4% of pupils with ova, reporting painful urination (PPV=26.1%, NPV=82.5%. Conclusion — This study emphasizes the

  6. Evaluation of Rib Fractures on a Single-in-plane Image Reformation of the Rib Cage in CT Examinations.

    Science.gov (United States)

    Dankerl, Peter; Seuss, Hannes; Ellmann, Stephan; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2017-02-01

    This study aimed to evaluate the diagnostic performance of using a reformatted single-in-plane image reformation of the rib cage for the detection of rib fractures in computed tomography (CT) examinations, employing different levels of radiological experience. We retrospectively evaluated 10 consecutive patients with and 10 patients without rib fractures, whose CT scans were reformatted to a single-in-plane image reformation of the rib cage. Eight readers (two radiologists, two residents in radiology, and four interns) independently evaluated the images for the presence of rib fractures using a reformatted single-in-plane image and a multi-planar image reformation. The time limit was 30 seconds for each read. A consensus of two radiologist readings was considered as the reference standard. Diagnostic performance (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) was assessed and evaluated per rib and per location (anterior, lateral, posterior). To determine the time limit, we prospectively analyzed the average time it took radiologists to assess the rib cage, in a bone window setting, in 50 routine CT examinations. McNemar test was used to compare the diagnostic performances. Single image reformation was successful in all 20 patients. The sensitivity, specificity, PPV, and NPV for the detection of rib fractures using the conventional multi-planar read were 77.5%, 99.2%, 89.9%, and 98.0% for radiologists; 46.3%, 99.7%, 92.5%, and 95.3% for residents; and 29.4%, 99.4%, 82.5%, and 93.9% for interns, respectively. Sensitivity, PPV, and NPV increased across all three groups of experience, using the reformatted single-in-plane image of the rib cage (radiologists: 85.0%, 98.6%, and 98.7%; residents: 80.0%, 92.8%, and 98.2%; interns: 66.9%, 89.9%, and 97.1%), whereas specificity did not change significantly (99.9%, 99.4%, and 99.3%). The diagnostic performance of the interns and residents was significantly better when

  7. Prospective study to evaluate the number and the location of biopsies in rapid urease test for diagnosis of Helicobacter Pylori

    Directory of Open Access Journals (Sweden)

    Antoine Abou Rached

    2017-11-01

    Full Text Available Helicobacter pylori (H. pylori can cause a wide variety of illnesses such as peptic ulcer disease, gastric adenocarcinoma and mucosa-associated lymphoid tissue (MALT lymphoma. The diagnosis and eradication of H. pylori are crucial. The diagnosis of H. pylori is usually based on the rapid urease test (RUT and gastric antral biopsy for histology. The aim of this study is to evaluate the numbers of needed biopsies and their location (antrum/fundus to obtain optimal result for the diagnosis of H. pylori. Three hundred fifty consecutive patients were recruited, 210 fulfill the inclusion criteria and had nine gastric biopsies for the detection of H. pylori infection: two antral for the first RUT (RUT1, one antral and one fundic for the second (RUT2, one antral for the third (RUT3 and two antral with two fundic for histology (HES, Giemsa, PAS. The reading of the 3 types of RUT was performed at 1 hour, 3 hours and 24 hours and biopsies were read by two experienced pathologists not informed about the result of RUT. Results of RUT were considered positive if H. pylori was found on histology of at least one biopsy. The RUT1 at 1h, 3h and 24h has a sensitivity of 72%, 82% and 89% and a specificity of 100%, 99% and 87% respectively. The positive predictive value (PPV was 100%, 99% and 85% respectively and the negative predictive value (NPV of 81%, 87% and 90%. The RUT2 at 1h, 3h and 24h, respectively, had a sensitivity of 86%, 87% and 91% and a specificity of 99%, 97% and 90%. The PPV was 99%, 96% and 88% and NPV of 89%, 90%, 94%. The RUT3 at 1h, 3h and 24h, respectively, had a sensitivity of 70%, 74% and 84% and a specificity of 99%, 99% and 94%. The PPV was 99%, 99% and 92% and NPV of 79%, 81% and 87%. The best sensitivity and specificity were obtained for RUT1 read at 3h, for RUT2 read 1h and 3h, and the RUT3 read at 24h.This study demonstrates that the best sensitivity and specificity of rapid test for urease is obtained when fundic plus antral biopsy

  8. The diagnostic performance of CT-derived fractional flow reserve for evaluation of myocardial ischaemia confirmed by invasive fractional flow reserve: a meta-analysis

    International Nuclear Information System (INIS)

    Li, S.; Tang, X.; Peng, L.; Luo, Y.; Dong, R.; Liu, J.

    2015-01-01

    Aim: To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFR CT ) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. Materials and methods: A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFR CT , with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Results: Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR−), and diagnostic odds ratio (DOR) for FFR CT were 89% (85–93%), 71% (65–75%), 70% (65–75%), 90% (85–93%), 3.31 (1.79–6.14), 0.16 (0.11–0.23), and 21.21 (9.15–49.15) at the patient-level, and 83% (78–63%), 78% (75–81%), 61% (56–65%), 92% (89–90%), 4.02 (1.84–8.80), 0.22 (0.13–0.35), and 19.15 (5.73–63.93) at the vessel-level. At per-patient analysis, FFR CT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR−, and DOR versus those of CTA. At per-vessel analysis, FFR CT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR−, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFR CT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. Conclusions: FFR CT , which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions

  9. Evaluation of an On-Farm Culture System (Accumast for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows.

    Directory of Open Access Journals (Sweden)

    Erika Korzune Ganda

    Full Text Available The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538 was cultured on-farm using a single plate containing three selective chromogenic media (Accumast-FERA Animal Health LCC, Ithaca, NY and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214. In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV and negative predictive value (NPV were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively.

  10. Evaluation of an On-Farm Culture System (Accumast) for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows.

    Science.gov (United States)

    Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho

    2016-01-01

    The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast-FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively.

  11. Investigation on I-V for Different Heating Temperatures of Nanocomposited MEH-PPV:CNTs Organic Solar Cells

    Directory of Open Access Journals (Sweden)

    M. S. P. Sarah

    2012-01-01

    Full Text Available This paper discussed the effect of different thermal evaporation treatments for nanocomposited MEH-PPV:CNTs thin films towards the performance of organic solar cells. The configuration of the organic solar cells is ITO/MEH-PPV:CNTs/Au. The heating temperature was varied from, as deposited, 50°C, 75°C, and 100°C. From the results, we observed that the efficiency increase slightly before decreasing back at 100°C. The highest efficiency was solar cells heated at 75°C with efficiency 0.001% which is supported by the I-V characteristics and also by the absorption spectra.

  12. Diagnostic Performance of Ultra-Low-Dose Computed Tomography for Detecting Asbestos-Related Pleuropulmonary Diseases: Prospective Study in a Screening Setting.

    Science.gov (United States)

    Schaal, Marysa; Severac, François; Labani, Aissam; Jeung, Mi-Young; Roy, Catherine; Ohana, Mickaël

    2016-01-01

    To evaluate the diagnostic performance of Ultra-Low-Dose Chest CT (ULD CT) for the detection of any asbestos-related lesions (primary endpoint) and specific asbestos-related abnormalities, i.e. non-calcified and calcified pleural plaques, diffuse pleural thickening, asbestosis and significant lung nodules (secondary endpoints). 55 male patients (55.7±8.1 years old) with occupational asbestos exposure for at least 15 years and where CT screening was indicated were prospectively included. They all underwent a standard unenhanced chest CT (120kV, automated tube current modulation), considered as the reference, and an ULD CT (135kV, 10mA), both with iterative reconstruction. Two chest radiologists independently and blindly read the examinations, following a detailed protocol. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy and error rate of ULD CT were calculated using the exact method of Pearson with a confidence interval of 95%. Radiation dose was 17.9±1.2mGy.cm (0.25mSv) for the ULD-CT versus 288.8 ±151mGy.cm (4mSv); p value = 100%, negative predictive value = 97.8%), high for lung nodules, diffuse pleural thickening and calcified pleural plaques (sensitivity, specificity, PPV and NPV = 100%) and fair for asbestosis (sensitivity = 75%, specificity = 100%, PPV = 00%, NPV = 98.1%). Intra-reader accuracy between the ULD CT and the reference CT for the primary endpoint was 98% for the senior and 100% for the junior radiologist. Inter-reader agreement for the primary endpoint was almost perfect (Cohen's Kappa of 0.81). ULD CT in the screening of asbestos exposure related diseases has 90.9% sensitivity and 100% specificity, and could therefore be proposed as a first line examination.

  13. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul, E-mail: paul.stolzmann@usz.ch [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetti, Robert; Baumueller, Stephan [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Plass, Andre; Falk, Volkmar [Clinic for Cardiovascular Surgery, University Hospital Zurich (Switzerland); Scheffel, Hans; Feuchtner, Gudrun; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Alkadhi, Hatem [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Leschka, Sebastian [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2011-07-15

    Objective: To compare, in patients with suspicion of coronary artery disease (CAD) and low heart rates, image quality, diagnostic performance, and radiation dose values of prospectively and retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (CTCA) for the diagnosis of significant coronary stenoses. Materials and methods: Two-hundred consecutive patients with heart rates {<=}70 bpm were retrospectively enrolled; 100 patients undergoing prospectively ECG-gated CTCA (group 1) and 100 patients undergoing retrospectively-gated CTCA (group 2). Coronary artery segments were assessed for image quality and significant luminal diameter narrowing. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy of both CTCA groups were determined using conventional catheter angiography (CCA) as reference standard. Radiation dose values were calculated. Results: Both groups were comparable regarding gender, body weight, cardiovascular risk profile, severity of CAD, mean heart rate, heart rate variability, and Agatston score (all p > 0.05). There was no significant difference in the rate of non-assessable coronary segments between group 1 (1.6%, 24/1404) and group 2 (1.4%, 19/1385; p = 0.77); non-diagnostic image quality was significantly (p < 0.001) more often attributed to stair step artifacts in group 1. Segment-based sensitivity, specificity, PPV, NPV, and accuracy were 98%, 98%, 88%, 100%, and 100% among group 1; 96%, 99%, 90%, 100%, and 98% among group 2, respectively. Parameters of diagnostic performance were similar (all p > 0.05). Mean effective radiation dose of prospectively ECG-gated CTCA (2.2 {+-} 0.4 mSv) was significantly (p < 0.0001) smaller than that of retrospectively ECG-gated CTCA (8.1 {+-} 0.6 mSv). Conclusion: Prospectively ECG-gated CTCA yields similar image quality, performs as accurately as retrospectively ECG-gated CTCA in patients having heart rates {<=}70 bpm

  14. 111In-Pentetreotide scintigraphy in medulloblastoma: A comparison with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yueksel, Mahmut; Lutterbey, Goetz; Biersack, Hans Juergen; Elke, Urs; Ezziddin, Samer; Hasan, Carola; Bode, Udo; Zairong Gao

    2007-01-01

    Medulloblastoma (MB) is a primitive neuroectodermal tumour constituting a grade IV brain malignancy. Early and correct detection of recurrence or metastasis is desirable for follow-up of patients in this entity. Frequent expression of somatostatin receptors by MB lesions facilitates functional tumour imaging by somatostatin receptor scintigraphy (SRS). To investigate the value of SRS in the follow-up of MB, the results of ten consecutive patients (seven children and three adults) undergoing additional imaging with 111 In-pentetreotide were reviewed. Four, 24 and 48 h p.i. planar and whole body images as well as a SPECT study at 4 h p.i. were acquired after intravenous injection of 109±35 MBq 111 In-pentetreotide (Octreoscan). SRS yielded 11 positive and ten negative imaging results, compared to 17 positive and four negative in magnetic resonance imaging (MRI). The lesion-by-lesion analysis with a total of 44 lesions revealed a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 42%, 83%, 94%, 18% for SRS and 89.5%, 50%, 92%, 43% for MRI. Based on a per-patient analysis, considering the patient as to be either tumour-free or tumour-positive by one imaging modality, the following values for sensitivity, specificity, PPV and NPV were obtained: 61%, 100%, 100%, 30% for SRS and 94%, 67%, 94%, 67% for MRI. MRI remains the first step imaging technique in medulloblastoma patients before and after surgery and during the follow-up providing the highest sensitivity. However, to improve specificity and contribute to correct diagnosis in MB 111 In-pentetreotide scintigraphy should be considered as a confirmatory second step imaging tool, especially in case of equivocal MRI results. Moreover, a positive SRS scan might serve as a reference before and after somatostatin receptor targeted radiotherapy

  15. Doppler ultrasound for detection of renal transplant artery stenosis - Threshold peak systolic velocity needs to be higher in a low-risk or surveillance population

    International Nuclear Information System (INIS)

    Patel, U.; Khaw, K.K.; Hughes, N.C.

    2003-01-01

    AIMS: To establish the ideal threshold arterial velocity for the diagnosis of renal transplant artery stenosis in a surveillance population with a low pre-test probability of stenosis. METHODS: Retrospective review of Doppler ultrasound, angiographic and clinical outcome data of patients transplanted over a 3-year period. Data used to calculate sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for various threshold peak systolic velocity values. RESULTS: Of 144 patients transplanted, full data were available in 117 cases. Five cases had renal transplant artery stenosis--incidence 4.2% [stenosis identified at a mean of 6.5 months (range 2-10 months)]. All five cases had a significant arterial pressure gradient across the narrowing and underwent angioplasty. Threshold peak systolic velocity of ≥2.5 m/s is not ideal [specificity=79% (CI 65-82%), PPV=18% (CI 6-32%), NPV=100% (CI 94-100%)], subjecting many patients to unnecessary angiography--8/117 (6%) in our population. Comparable values if the threshold is set at ≥3.0 m/s are 93% (CI 77-96%), 33% (CI 7-44%) and 99% (CI 93-100%), respectively. The clinical outcome of all patients was satisfactory, with no unexplained graft failures or loss. CONCLUSIONS: In a surveillance population with a low pre-test probability of stenosis, absolute renal artery velocity ≥2.5 m/s is a limited surrogate marker for significant renal artery stenosis. The false-positive rate is high, and ≥3.0 m/s is a better choice which will halve the number of patients enduring unnecessary angiography. Close clinical follow-up of patients in the 2.5-3.0 m/s range, with repeat Doppler ultrasound if necessary, will identify the test false-negatives

  16. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta

    Directory of Open Access Journals (Sweden)

    Elham Naghshineh

    2015-01-01

    Conclusions: Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta.

  17. The Bombyx mori nucleopolyhedrovirus (BmNPV) ODV-E56 envelope protein is also a per os infectivity factor.

    Science.gov (United States)

    Xiang, Xingwei; Chen, Lin; Guo, Aiqin; Yu, Shaofang; Yang, Rui; Wu, Xiaofeng

    2011-01-01

    The Bombyx mori nucleopolyhedrovirus (BmNPV) odv-e56 gene is a late gene and encodes an occlusion-derived virus (ODV)-specific envelope protein, ODV-E56. To determine its role in the BmNPV life cycle, an odv-e56 null virus, BmE56D, was constructed through homologous recombination. A repaired virus was also constructed, named BmE56DR. The production of budded virion (BV) and polyhedra, the replication of viral DNA, and the morphological of infected BmN cells were analyzed, revealing no significant difference among the BmE56D, the wild-type (WT), and the BmE56DR virus. Larval bioassays demonstrated that injection of BmE56D BV into the hemocoel could kill B. mori larvae as efficiently as repaired and WT viruses, however BmE56D was unable to infect the B. mori larvae when inoculated per os. Thus, these results indicated that ODV-E56 envelope protein of BmNPV is also a per os infectivity factor (PIF), but is not essential for virus replication. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Annealing temperature effect on electrical properties of MEH-PPV thin film via spin coating method

    Science.gov (United States)

    Azhar, N. E. A.; Shariffudin, S. S.; Alrokayan, Salman A. H.; Khan, Haseeb A.; Rusop, M.

    2018-05-01

    Organic semiconductor has been discovered in different application devices such as organic light emitting diodes (OLEDs). Poly [2-methoxy-5(2' -ethylhexyloxy)-1, 4-phenylenevinylene), MEH-PPV widely used in this device because its ability to produce a good optical quality films. The MEH-PPV was prepared on glass substrate by spin coating method. The thin film was investigated at different annealing temperatures. The scanning electron micrographs (SEM) revealed that sample annealed at 50°C showed uniformity and less aggregation on morphology polymer thin film. Optical properties showed the intensities of visible emission increased as temperatures increased. The current-voltage (I-V) measurement revealed that the temperature of 50°C showed high conductive and it is suitable for optoelectronic device.

  19. Effect of gadolinium injection on diffusion-weighted imaging with background body signal suppression (DWIBS) imaging of breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-12-01

    Diffusion-weighted imaging with background body signal suppression (DWIBS) provides both qualitative and quantitative imaging of breast lesions and are usually performed before contrast material injection (CMI). This study aims to assess whether the administration of gadolinium significantly affects DWIBS imaging. 200 patients were prospectively evaluated by MRI with STIR, TSE-T2, pre-CMI DWIBS, contrast enhanced THRIVE-T1 and post-CMI DWIBS sequences. Pre and post-CMI DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3) mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated for both sequences and represented by ROC analysis. Pre and post-CMI ADC values were compared by using the paired t test. In 150/200 (59%) patients, pre and post-CMI DWIBS indicated the presence of breast lesions, 53 (35%) with ADC values of >1.44×10(-3) mm(2)/s and 97 (65%) with ADC≤1.44×10(-3) mm(2)/s. Pre-CMI and post-DWIBS sequences obtained the same sensitivity, specificity, DA, PPV and NPV values of 97%, 83%, 89%, 79% and 98%. The mean ADC value of benign lesions was 1.831±0.18×10(-3) mm(2)/s before and 1.828±0.18×10(-3) mm(2)/s after CMI. The mean ADC value of the malignant lesions was 1.146±0.16×10(-3) mm(2)/s before and 1.144±0.16×10(-3) mm(2)/s after CMI. No significant difference was found between pre and post CMI ADC values (p>0.05). DWIBS imaging is not influenced by CMI. Breast MR protocol could be modified by placing DWIBS after dynamic contrast enhanced sequences in order to maximize patient cooperation. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Plasma levels and diagnostic utility of VEGF, MMP-2 and TIMP-2 in the diagnostics of breast cancer patients.

    Science.gov (United States)

    Ławicki, Sławomir; Zajkowska, Monika; Głażewska, Edyta Katarzyna; Będkowska, Grażyna Ewa; Szmitkowski, Maciej

    2017-03-01

    We investigated plasma levels and diagnostic utility of vascular endothelial growth factor VEGF, matrix metalloproteinase-2 (MMP-2) and tissue inhibitors of metalloproteinase-2 (TIMP-2) in comparison to cancer antigen 15-3 (CA 15-3). Plasma levels of tested parameters were determined using enzyme-linked immunosorbent assay (ELISA) while CA 15-3 with chemiluminescent microparticle immunoassay (CMIA). The plasma levels of VEGF, TIMP-2 showed significantly higher than CA 15-3 values of the diagnostic sensitivity, the predictive values of positive and negative test results (PPV, NPV) and the area under the receiver-operating characteristics (ROC) curve (AUC) in early stages of breast cancer (BC). The combined use of the tested parameters with CA 15-3 resulted in the increase in sensitivity, NPV and AUC, especially in the combination with VEGF (83%; 72%; 0.888) and TIMP-2 (83%; 72%; 0.894). The highest values were obtained for combination of all three parameters (93%; 85%; 0.923). These findings suggest the usefulness of the tested parameters in the diagnosis of BC, especially VEGF and TIMP-2 with CA 15-3 in early stages of BC, which could be a new diagnostic panel.

  1. Elimination of PPV and PNRSV through thermotherapy and meristem-tip culture in nectarine.

    Science.gov (United States)

    Manganaris, G A; Economou, A S; Boubourakas, I N; Katis, N I

    2003-10-01

    The plum pox virus (PPV) and prunus necrotic ringspot virus (PNRSV) cause serious disease problems in stone-fruit trees. In this work, the possibility of obtaining plant material free from these viruses through thermotherapy and meristem-tip culture from infected nectarine shoots (Prunus persica var. nectarina Max, cv. 'Arm King') was studied. In addition, the detection of these viruses in in vitro cultures and young acclimatized plantlets with double antibody sandwich-enzyme-linked immunosorbent assay (DAS-ELISA) and multiplex reverse transcriptase-polymerase chain reaction (RT-PCR) was studied. Meristem-tip explants (0.8-1.3 mm) derived from sprouted buds of winter wood and spring shoots from field grown plants had a 2-5% regeneration response. However, application of thermotherapy to potted nectarine trees (3 weeks at a maximum temperature of 35 degrees C) facilitated excision of longer meristem tips (1.3-2.0 mm) that resulted in a significantly higher regeneration response (38%) in woody plant medium (WPM) without plant growth regulators. Such explants formed multiple shoots with the addition of 8 microM benzylaminopurine and 0.8 microM indoleacetic acid. When they were tested for the presence of PPV and PNRSV, 86% and 81% were found to be virus-free as detected by DAS-ELISA and multiplex RT-PCR, respectively. Individual shoots excised from virus-free cultures readily rooted in vitro (half-strength WPM plus 2 microM indolebutyric acid) and grew to plantlets. The combination of an efficient protocol for virus elimination and the establishment of highly sensitive diagnostics resulted in the production of nectarine plants free from PPV and PNRSV.

  2. Office gel sonovaginography for the prediction of posterior deep infiltrating endometriosis: a multicenter prospective observational study.

    Science.gov (United States)

    Reid, S; Lu, C; Hardy, N; Casikar, I; Reid, G; Cario, G; Chou, D; Almashat, D; Condous, G

    2014-12-01

    To use office gel sonovaginography (SVG) to predict posterior deep infiltrating endometriosis (DIE) in women undergoing laparoscopy. This was a multicenter prospective observational study carried out between January 2009 and February 2013. All women were of reproductive age, had a history of chronic pelvic pain and underwent office gel SVG assessment for the prediction of posterior compartment DIE prior to laparoscopic endometriosis surgery. Gel SVG findings were compared with laparoscopic findings to determine the diagnostic accuracy of office gel SVG for the prediction of posterior compartment DIE. In total, 189 women underwent preoperative gel SVG and laparoscopy for endometriosis. At laparoscopy, 57 (30%) women had posterior DIE and 43 (23%) had rectosigmoid/anterior rectal DIE. For the prediction of rectosigmoid/anterior rectal (i.e. bowel) DIE, gel SVG had an accuracy of 92%, sensitivity of 88%, specificity of 93%, positive predictive value (PPV) of 79%, negative predictive value (NPV) of 97%, positive likelihood ratio (LR+) of 12.9 and negative likelihood ratio (LR-) of 0.12 (P = 3.98E-25); for posterior vaginal wall and rectovaginal septum (RVS) DIE, respectively, the accuracy was 95% and 95%, sensitivity was 18% and 18%, specificity was 99% and 100%, PPV was 67% and 100%, NPV was 95% and 95%, LR+ was 32.4 and infinity and LR- was 0.82 and 0.82 (P = 0.009 and P = 0.003). Office gel SVG appears to be an effective outpatient imaging technique for the prediction of bowel DIE, with a higher accuracy for the prediction of rectosigmoid compared with anterior rectal DIE. Although the sensitivity for vaginal and RVS DIE was limited, gel SVG had a high specificity and NPV for all forms of posterior DIE, indicating that a negative gel SVG examination is highly suggestive of the absence of DIE at laparoscopy. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  3. Clinical usefulness of the nested polymerase chain reaction in the diagnosis of extrapulmonary tuberculosis Utilidad clínica de la reacción en cadena de la polimerasa anidada para el diagnóstico de tuberculosis extrapulmonar

    Directory of Open Access Journals (Sweden)

    Guadalupe García-Elorriaga

    2009-06-01

    Full Text Available OBJECTIVE:To evaluate the effectiveness of nested polymerase chain reaction (PCR for diagnosis of extrapulmonary tuberculosis (ETB, as well as the impact of PCR results on clinical management. MATERIALS AND METHODS:We conducted a study of nested PCR tests in 45 patients and a review of patient hospital files, calculating sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV. RESULTS:PCR was positive in 51% of cases; PCR sensitivity for diagnosing TB was 86%, specificity was 79%, PPV was 76%, and NPV was 88%. When solely analyzing urine samples, sensitivity and NPV increased to 100%. PCR exerted an influence on management in 27% of patients. CONCLUSIONS:PCR for rapid diagnosis of extrapulmonary TB has an adequate effect, which improves when performed on urine. The results of PCR exerted an acceptable impact on the clinical management of these patients.OBJETIVO:Evaluar la eficacia de la reacción en cadena de la polimerasa (PCR anidada para el diagnóstico de tuberculosis extrapulmonar, así como el impacto de sus resultados en el manejo clínico. MATERIAL Y MÉTODOS: Se realizó PCR anidada en 45 pacientes y se llevó a cabo la revisión de expedientes. Se calculó sensibilidad, especificidad, valor predictivo positivo (VPP y valor predictivo negativo (VPN. RESULTADOS:La PCR fue positiva en 51% de los casos, la sensibilidad fue de 86%, la especificidad de 79%, el VPP de 76% y el VPN de 88%. Al analizar solamente las muestras de orina, la sensibilidad y VPN se incrementaron a 100%. La PCR influyó en el manejo de 27% de los pacientes. CONCLUSIONES:La PCR para el diagnóstico rápido de TB extrapulmonar tiene una eficacia adecuada, la cual mejora cuando se realiza en orina. El resultado de la PCR tuvo un impacto aceptable en el manejo clínico de estos pacientes.

  4. Assessment of the performances of AcuStar HIT and the combination with heparin-induced multiple electrode aggregometry: a retrospective study.

    Science.gov (United States)

    Minet, V; Bailly, N; Douxfils, J; Osselaer, J C; Laloy, J; Chatelain, C; Elalamy, I; Chatelain, B; Dogné, J M; Mullier, F

    2013-09-01

    Early diagnosis of immune heparin-induced thrombocytopenia (HIT) is challenging. HemosIL® AcuStar HIT and heparin-induced multiple electrode aggregometry (HIMEA) were recently proposed as rapid diagnostic methods. We conducted a study to assess performances of AcuStar HIT-IgG (PF4-H) and AcuStar HIT-Ab (PF4-H). The secondary objective was to compare the performances of the combination of Acustar HIT and HIMEA with standardised clinical diagnosis. Sera of 104 suspected HIT patients were retrospectively tested with AcuStar HIT. HIMEA was performed on available sera (n=81). The clinical diagnosis was established by analysing in a standardized manner the patient's medical records. These tests were also compared with PF4-Enhanced®, LTA, and SRA in subsets of patients. Thresholds were determined using ROC curve analysis with clinical outcome as reference. Using the recommended thresholds (1.00AU), the negative predictive value (NPV) of HIT-IgG and HIT-Ab were 100.0% (95% CI: 95.9%-100.0% and 95.7%-100.0%). The positive predictive value (PPV) were 64.3% (95% CI: 35.1%-87.2.2%) and 45.0% (95% CI: 23.2%-68.6%), respectively. Using our thresholds (HIT-IgG: 2.89AU, HIT-Ab: 9.41AU), NPV of HIT-IgG and HIT-Ab were 100.0% (95% CI: 96.0%-100.0% and 96.1%-100.0%). PPV were 75.0% (95% CI: 42.7%-94.5%) and 81.8% (95% CI: 48.3%-97.7%), respectively. Of the 79 patients with a medium-high pretest probability score, 67 were negative using HIT-IgG (PF4-H) test at our thresholds. HIMEA was performed on HIT-IgG positive patients. Using this combination, only one patient on 79 was incorrectly diagnosed. Acustar HIT showed good performances to exclude the diagnosis of HIT. Combination with HIMEA improves PPV. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Fluorescence blinking in MEH-PPV single molecules at low temperature

    International Nuclear Information System (INIS)

    Mirzov, O.; Cichos, F.; Borczyskowski, C. von; Scheblykin, I.

    2005-01-01

    Fluorescence intensity transients of single molecules of the conjugated polymer poly[2-methoxy,5-(2'-ethylhexyloxy)-p-phenylene-vinylene] (MEH-PPV) were studied at 15 K. Fluorescence blinking behavior was observed despite the expected low-temperature suppression of energy migration in such disordered molecular systems. Presence of the fluorescence blinking effect at 15 K indicates that the single molecules possess a collapsed conformation with characteristic size of not more than several nanometers, which corresponds to only a few exciton hops over a polymer chain

  6. NPV-LDE-225 (Erismodegib) inhibits epithelial mesenchymal transition and self-renewal of glioblastoma initiating cells by regulating miR-21, miR-128, and miR-200.

    Science.gov (United States)

    Fu, Junsheng; Rodova, Mariana; Nanta, Rajesh; Meeker, Daniel; Van Veldhuizen, Peter J; Srivastava, Rakesh K; Shankar, Sharmila

    2013-06-01

    Glioblastoma multiforme is the most common form of primary brain tumor, often characterized by poor survival. Glioblastoma initiating cells (GICs) regulate self-renewal, differentiation, and tumor initiation properties and are involved in tumor growth, recurrence, and resistance to conventional treatments. The sonic hedgehog (SHH) signaling pathway is essential for normal development and embryonic morphogenesis. The objectives of this study were to examine the molecular mechanisms by which GIC characteristics are regulated by NPV-LDE-225 (Smoothened inhibitor; (2,2'-[[dihydro-2-(4-pyridinyl)-1,3(2H,4H)-pyrimidinediyl]bis(methylene)]bis[N,N-dimethylbenzenamine). Cell viability and apoptosis were measured by XTT and annexin V-propidium iodide assay, respectively. Gli translocation and transcriptional activities were measured by immunofluorescence and luciferase assay, respectively. Gene and protein expressions were measured by quantitative real-time PCR and Western blot analyses, respectively. NPV-LDE-225 inhibited cell viability, neurosphere formation, and Gli transcriptional activity and induced apoptosis by activation of caspase-3 and cleavage of poly(ADP-ribose) polymerase. NPV-LDE-225 increased the expression of tumor necrosis factor-related apoptosis inducing ligand (TRAIL)-R1/DR4, TRAIL-R2/DR5, and Fas and decreased the expression of platelet derived growth factor receptor-α and Bcl2, and these effects were abrogated by Gli1 plus Gli2 short hairpin RNAs. NPV-LDE-225 enhanced the therapeutic potential of FasL and TRAIL by upregulating Fas and DR4/5, respectively. Interestingly, NPV-LDE-225 induced expression of programmed cell death 4 and apoptosis and inhibited cell viability by suppressing micro RNA (miR)-21. Furthermore, NPV-LDE-225 inhibited pluripotency-maintaining factors Nanog, Oct4, Sox2, and cMyc. The inhibition of Bmi1 by NPV-LDE-225 was regulated by induction of miR-128. Finally, NPV-LDE-225 suppressed epithelial-mesenchymal transition by

  7. Can routine chest radiography be used to diagnose mild COPD? A nested case-control study.

    Science.gov (United States)

    den Harder, A M; Snoek, A M; Leiner, T; Suyker, W J; de Heer, L M; Budde, R P J; Lammers, J W J; de Jong, P A; Gondrie, M J A

    2017-07-01

    To determine whether mild stage chronic obstructive pulmonary disease (COPD) can be detected on chest radiography without substantial overdiagnosis. A retrospective nested case-control study (case:control, 1:1) was performed in 783 patients scheduled for cardiothoracic surgery who underwent both spirometry and a chest radiograph preoperative. Diagnostic accuracy of chest radiography for diagnosing mild COPD was investigated using objective measurements and overall appearance specific for COPD on chest radiography. Inter-observer variability was investigated and variables with a kappa >0.40 as well as baseline characteristics were used to make a diagnostic model which was aimed at achieving a high positive predictive value (PPV). Twenty percent (155/783) had COPD. The PPV of overall appearance specific for COPD alone was low (37-55%). Factors in the diagnostic model were age, type of surgery, gender, distance of the right diaphragm apex to the first rib, retrosternal space, sternodiaphragmatic angle, maximum height right diaphragm (lateral view) and subjective impression of COPD (using both views). The model resulted in a PPV of 100%, negative predictive value (NPV) of 82%, sensitivity of 10% and specificity of 100% with an area under the curve of 0.811. Detection of mild COPD without substantial overdiagnosis was not feasible on chest radiographs in our cohort. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Combining High Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction.

    Science.gov (United States)

    van der Linden, Noreen; Wildi, Karin; Twerenbold, Raphael; Pickering, John W; Than, Martin; Cullen, Louise; Greenslade, Jaimi; Parsonage, William; Nestelberger, Thomas; Boeddinghaus, Jasper; Badertscher, Patrick; Rubini Giménez, Maria; Klinkenberg, Lieke J J; Bekers, Otto; Schöni, Aline; Keller, Dagmar I; Sabti, Zaid; Puelacher, Christian; Cupa, Janosch; Schumacher, Lukas; Kozhuharov, Nikola; Grimm, Karin; Shrestha, Samyut; Flores, Dayana; Freese, Michael; Stelzig, Claudia; Strebel, Ivo; Miró, Òscar; Rentsch, Katharina; Morawiec, Beata; Kawecki, Damian; Kloos, Wanda; Lohrmann, Jens; Richards, A Mark; Troughton, Richard; Pemberton, Christopher; Osswald, Stefan; van Dieijen-Visser, Marja P; Mingels, Alma M; Reichlin, Tobias; Meex, Steven J R; Mueller, Christian

    2018-04-24

    Background -Combining two signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction (AMI) with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of AMI. Methods -The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected AMI. The optimal rule out and rule in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule out was compared with the ESC 0/1 and 0/3 hour algorithms. Results -Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the ESC 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule out criteria after the baseline blood sampling was limited (6-24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng2/L2) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34-41% in the original (sum: negative predictive value (NPV) 100% (95%CI: 99.5-100%); product: NPV 100% (95%CI: 99.5-100%) and in the validation cohort (sum: NPV 99.6% (95%CI: 99.0-99.9%); product: NPV 99.4% (95%CI: 98.8-99.8%). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule out (40-43% ruled out; NPV original cohort 99.9% (95%CI: 99.2-100%); NPV

  9. The Impact of Variability of Selected Geological and Mining Parameters on the Value and Risks of Projects in the Hard Coal Mining Industry

    Science.gov (United States)

    Kopacz, Michał

    2017-09-01

    The paper attempts to assess the impact of variability of selected geological (deposit) parameters on the value and risks of projects in the hard coal mining industry. The study was based on simulated discounted cash flow analysis, while the results were verified for three existing bituminous coal seams. The Monte Carlo simulation was based on nonparametric bootstrap method, while correlations between individual deposit parameters were replicated with use of an empirical copula. The calculations take into account the uncertainty towards the parameters of empirical distributions of the deposit variables. The Net Present Value (NPV) and the Internal Rate of Return (IRR) were selected as the main measures of value and risk, respectively. The impact of volatility and correlation of deposit parameters were analyzed in two aspects, by identifying the overall effect of the correlated variability of the parameters and the indywidual impact of the correlation on the NPV and IRR. For this purpose, a differential approach, allowing determining the value of the possible errors in calculation of these measures in numerical terms, has been used. Based on the study it can be concluded that the mean value of the overall effect of the variability does not exceed 11.8% of NPV and 2.4 percentage points of IRR. Neglecting the correlations results in overestimating the NPV and the IRR by up to 4.4%, and 0.4 percentage point respectively. It should be noted, however, that the differences in NPV and IRR values can vary significantly, while their interpretation depends on the likelihood of implementation. Generalizing the obtained results, based on the average values, the maximum value of the risk premium in the given calculation conditions of the "X" deposit, and the correspondingly large datasets (greater than 2500), should not be higher than 2.4 percentage points. The impact of the analyzed geological parameters on the NPV and IRR depends primarily on their co-existence, which can be

  10. Evaluation of capability of ultrasound with elastometry and elastography for diagnosis of subclinical regional metastases of cancer of the oral mucosa

    Directory of Open Access Journals (Sweden)

    Yu. V. Alymov

    2017-01-01

    predictive value (PPV was estimated as 0 %, and negative predictive value (NPV as 90.1 %. USI with elastography was characterized by 100 % specificity, 83.3 % sensitivity, 95.5 % accuracy, and 91.7 % efficacy. PPV was estimated as 100 %, and NPV as 94.1 %. Threshold value of elastometry for diagnosis of occult metastases was 2.42 m/s with 83.3 sensitivity, and 87.5 % specificity. Method was characterized by 86.4 % accuracy, 85.4 efficacy, 71.4 % PPV and 93.3 % NPV.Conclusion. B-mode USI is characterized by low capability for diagnosis of subclinical regional metastases of squamous cell carcinoma of the oral mucosa. Elastometry and elastography offer a possibility to increase USI accuracy for diagnosis of subclinical regional metastases from 80 % to 86-95.5 % and efficacy from 44 % to 85–92 %.

  11. Profluorescent PPV-Based Micellar System as a Versatile Probe for Bioimaging and Drug Delivery.

    Science.gov (United States)

    Zaquen, Neomy; Lu, Hongxu; Chang, Teddy; Mamdooh, Russel; Lutsen, Laurence; Vanderzande, Dirk; Stenzel, Martina; Junkers, Thomas

    2016-12-12

    Although micelles are commonly used for drug delivery purposes, their long-term fate is often unknown due to photobleaching of the fluorescent labels or the use of toxic materials. Here, we present a metal-free, nontoxic, nonbleaching, fluorescent micelle that can address these shortcomings. A simple, yet versatile, profluorescent micellar system, built from amphiphilic poly(p-phenylenevinylene) (PPV) block copolymers, for use in drug delivery applications is introduced. Polymer micelles made from PPV show excellent stability for up to 1 year and are successfully loaded with anticancer drugs (curcumin or doxorubicin) without requiring introduction of physical or chemical cross-links. The micelles are taken up efficiently by the cells, which triggers disassembly, releasing the encapsulated material. Disassembly of the micelles and drug release is conveniently monitored as fluorescence of the single polymer chains appear, which enables not only to monitor the release of the payload, but in principle also the fate of the polymer over longer periods of time.

  12. A large interconnecting network within hybrid MEH-PPV/TiO2 nanorod photovoltaic devices

    International Nuclear Information System (INIS)

    Zeng, T-W; Lin, Y-Y; Lo, H-H; Chen, C-W; Chen, C-H; Liou, S-C; Huang, H-Y; Su, W-F

    2006-01-01

    This is a study of hybrid photovoltaic devices based on TiO 2 nanorods and poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV). We use TiO 2 nanorods as the electron acceptors and conduction pathways. Here we describe how to develop a large interconnecting network within the photovoltaic device fabricated by inserting a layer of TiO 2 nanorods between the MEH-PPV:TiO 2 nanorod hybrid active layer and the aluminium electrode. The formation of a large interconnecting network provides better connectivity to the electrode, leading to a 2.5-fold improvement in external quantum efficiency as compared to the reference device without the TiO 2 nanorod layer. A power conversion efficiency of 2.2% under illumination at 565 nm and a maximum external quantum efficiency of 24% at 430 nm are achieved. A power conversion efficiency of 0.49% is obtained under Air Mass 1.5 illumination

  13. A Novel Geriatric Screening Tool in Older Patients with Cancer: The Korean Cancer Study Group Geriatric Score (KG-7.

    Directory of Open Access Journals (Sweden)

    Jin Won Kim

    Full Text Available Geriatric assessment (GA is resource-consuming, necessitating screening tools to select appropriate patients who need full GA. The objective of this study is to design a novel geriatric screening tool with easy-to-answer questions and high performance objectively selected from a large dataset to represent each domain of GA. A development cohort was constructed from 1284 patients who received GA from May 2004 to April 2007. Items representing each domain of functional status, cognitive function, nutritional status, and psychological status in GA were selected according to sensitivity (SE and specificity (SP. Of the selected items, the final questions were chosen by a panel of oncologists and geriatricians to encompass most domains evenly and also by feasibility and use with cancer patients. The selected screening questions were validated in a separate cohort of 98 cancer patients. The novel screening tool, the Korean Cancer Study Group Geriatric Score (KG-7, consisted of 7 items representing each domain of GA. KG-7 had a maximal area under the curve (AUC of 0.93 (95% confidence interval (CI 0.92-0.95 in the prediction of abnormal GA, which was higher than that of G-8 (0.87, 95% CI 0.85-0.89 within the development cohort. The cut-off value was decided at ≤ 5 points, with a SE of 95.0%, SP of 59.2%, positive predictive value (PPV of 85.3%, and negative predictive value (NPV of 82.6%. In the validation cohort, the AUC was 0.82 (95% CI 0.73-0.90, and the SE, SP, PPV, and NPV were 89.5%, 48.6%, 77.3%, and 75.0%, respectively. Furthermore, patients with higher KG-7 scores showed significantly longer overall survival (OS in the development and validation cohorts. In conclusions, the KG-7 showed high SE and NPV to predict abnormal GA. The KG-7 also predicted OS. Given the results of our studies, the KG-7 could be used effectively in countries with high patient burden and low resources to select patients in need of full GA and intervention.

  14. Comparison of platelet counts by sysmex XE 2100 and LH-750 with the international flow reference method in thrombocytopenic patients

    Directory of Open Access Journals (Sweden)

    Tina Dadu

    2013-01-01

    Full Text Available Background: There are several methods for counting platelets, of which the international flow reference method (IRM is considered to be the gold standard. We compared the platelet count given by this method to the count given by automated analyzers using other methods, such as optical fluorescence and impedance. Aims: The aim of this study is to compare the platelet counts obtained by Sysmex XE 2100 by Impedance (Sysmex-I, optical florescence (Sysmex-O and reported (Sysmex-R based on the switching algorithm and LH-750 by Impedance (LH-750 with the IRM in thrombocytopenic blood samples. To calculate the sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of various technologies at the clinically relevant transfusion thresholds of 10 × 10 9 /l and 20 × 10 9 /l. Materials and Methods: A total of 118 blood samples with platelet count of <50 × 10 9 /l were selected for the study. Platelet counts of all samples were analyzed by all methods using the Sysmex analyzer, LH-750 and IRM in parallel within 6 h of collection. Statistical Analysis Used: Pearson correlation, bland Altman analysis, sensitivity and specificity, PPV and NPV. Results and Conclusions: Sysmex-R had the least Bias and 95% limits of agreement (95%LA range and thus correlated best with IRM values. LH-750 had a higher Bias compared to Sysmex-O and Sysmex-R, but a strikingly similar 95% LA ensures similar results in all three methods. In fact, in the oncology subset, it had the narrowest 95% LA, which made it the best performer in this subgroup. Of the three Sysmex results, Sysmex-I had the highest bias, widest 95% LA and highest potential risk of over transfusion. Hence, Sysmex-R and LH-750 were found to be reliable tools for estimation of platelet count in thrombocytopenic patients.

  15. Limitations of 64-Detector-Row Computed Tomography Coronary Angiography: Calcium and Motion but not Short Experience

    International Nuclear Information System (INIS)

    Mir-Akbari, H.; Ripsweden, J.; Jensen, J.; Pichler, P.; Sylven, C.; Cederlund, K.; Rueck, A.

    2009-01-01

    Background: Recently, 64-detector-row computed tomography coronary angiography (CTA) has been introduced for the noninvasive diagnosis of coronary artery disease. Purpose: To evaluate the diagnostic capacity and limitations of a newly established CTA service. Material and Methods: In 101 outpatients with suspected coronary artery disease, 64-detector-row CTA (VCT Lightspeed 64; GE Healthcare, Milwaukee, WI., USA) was performed before invasive coronary angiography (ICA). The presence of >50% diameter coronary stenosis on CTA was rated by two radiologists recently trained in CTA, and separately by an experienced colleague. Diagnostic performance of CTA was calculated on segment, vessel, and patient levels, using ICA as a reference. Segments with a proximal reference diameter <2 mm or with stents were not analyzed. Results: In 51 of 101 patients and 121 of 1280 segments, ICA detected coronary stenosis. In 274 of 1280 (21%) segments, CTA had non-diagnostic image quality, the main reasons being severe calcifications (49%), motion artifacts associated with high or irregular heart rate (45%), and low contrast opacification (14%). Significantly more women (43%) had non-diagnostic scans compared to men (20%). A heart rate above 60 beats per minute was associated with significantly more non-diagnostic patients (38% vs. 18%). In the 1006 diagnostic segments, CTA had a sensitivity of 78%, specificity of 95%, positive predictive value (PPV) of 54%, and negative predictive value (NPV) of 98% for detecting significant coronary stenosis. In 29 patients, CTA was non-diagnostic. In the remaining 72 patients, sensitivity was 100%, specificity 65%, PPV 79%, and NPV 100%. The use of a more experienced CTA reader did not improve diagnostic performance. Conclusion: CTA had a very high negative predictive value, but the number of non-diagnostic scans was high, especially in women. The main limitations were motion artifacts and vessel calcifications, while short experience in CTA did not

  16. Cerebral 18F-FDG PET in macrophagic myofasciitis: An individual SVM-based approach.

    Science.gov (United States)

    Blanc-Durand, Paul; Van Der Gucht, Axel; Guedj, Eric; Abulizi, Mukedaisi; Aoun-Sebaiti, Mehdi; Lerman, Lionel; Verger, Antoine; Authier, François-Jérôme; Itti, Emmanuel

    2017-01-01

    Macrophagic myofasciitis (MMF) is an emerging condition with highly specific myopathological alterations. A peculiar spatial pattern of a cerebral glucose hypometabolism involving occipito-temporal cortex and cerebellum have been reported in patients with MMF; however, the full pattern is not systematically present in routine interpretation of scans, and with varying degrees of severity depending on the cognitive profile of patients. Aim was to generate and evaluate a support vector machine (SVM) procedure to classify patients between healthy or MMF 18F-FDG brain profiles. 18F-FDG PET brain images of 119 patients with MMF and 64 healthy subjects were retrospectively analyzed. The whole-population was divided into two groups; a training set (100 MMF, 44 healthy subjects) and a testing set (19 MMF, 20 healthy subjects). Dimensionality reduction was performed using a t-map from statistical parametric mapping (SPM) and a SVM with a linear kernel was trained on the training set. To evaluate the performance of the SVM classifier, values of sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and accuracy (Acc) were calculated. The SPM12 analysis on the training set exhibited the already reported hypometabolism pattern involving occipito-temporal and fronto-parietal cortices, limbic system and cerebellum. The SVM procedure, based on the t-test mask generated from the training set, correctly classified MMF patients of the testing set with following Se, Sp, PPV, NPV and Acc: 89%, 85%, 85%, 89%, and 87%. We developed an original and individual approach including a SVM to classify patients between healthy or MMF metabolic brain profiles using 18F-FDG-PET. Machine learning algorithms are promising for computer-aided diagnosis but will need further validation in prospective cohorts.

  17. Abbreviated Combined MR Protocol: A New Faster Strategy for Characterizing Breast Lesions.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2016-06-01

    The use of an abbreviated magnetic resonance (MR) protocol has been recently proposed for cancer screening. The aim of our study is to evaluate the diagnostic accuracy of an abbreviated MR protocol combining short TI inversion recovery (STIR), turbo-spin-echo (TSE)-T2 sequences, a pre-contrast T1, and a single intermediate (3 minutes after contrast injection) post-contrast T1 sequence for characterizing breast lesions. A total of 470 patients underwent breast MR examination for screening, problem solving, or preoperative staging. Two experienced radiologists evaluated both standard and abbreviated protocols in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for both protocols were calculated (with the histological findings and 6-month ultrasound follow-up as the reference standard) and compared with the McNemar test. The post-processing and interpretation times for the MR images were compared with the paired t test. In 177 of 470 (38%) patients, the MR sequences detected 185 breast lesions. Standard and abbreviated protocols obtained sensitivity, specificity, diagnostic accuracy, PPV, and NPV values respectively of 92%, 92%, 92%, 68%, and 98% and of 89%, 91%, 91%, 64%, and 98% with no statistically significant difference (P < .0001). The mean post-processing and interpretation time were, respectively, 7 ± 1 minutes and 6 ± 3.2 minutes for the standard protocol and 1 ± 1.2 minutes and 2 ± 1.2 minutes for the abbreviated protocol, with a statistically significant difference (P < .01). An abbreviated combined MR protocol represents a time-saving tool for radiologists and patients with the same diagnostic potential as the standard protocol in patients undergoing breast MRI for screening, problem solving, or preoperative staging. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Rectosigmoid endometriosis: comparison between CT water enema and video laparoscopy.

    Science.gov (United States)

    Stabile Ianora, A A; Moschetta, M; Lorusso, F; Lattarulo, S; Telegrafo, M; Rella, L; Scardapane, A

    2013-09-01

    To evaluate the accuracy of water enema computed tomography (CT) for predicting the location of endometriosis in patients with contraindications to magnetic resonance imaging (MRI), focusing on rectosigmoid lesions and having laparoscopic and histological data as the reference standard. Thirty-three women (mean age 33.4 ± 3.1 years) suspected of having deep pelvic endometriosis underwent 64-row CT and video laparoscopy within 4 weeks. Two radiologists blinded to the clinical data evaluated the CT images obtained after colonic retrograde distension using water as the contrast medium, and a comparison with laparoscopic and histological findings was performed. CT sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. The radiation dose to patients was estimated. Cohen's weighted kappa (κ) test was used to evaluate the interobserver agreement. In 23 out of 33 patients (69%) intestinal implants were found at surgery and pathological examinations. CT confirmed the diagnosis of rectosigmoid endometriosis in 20 out of 23 implants. Three nodules located on the proximal sigmoid colon (two serosal lesions and one infiltrating the muscularis layer) with a diameter of less than 1 cm were not diagnosed. CT sensitivity, specificity, PPV, NPV, and accuracy values were 87, 100, 100, 77, and 91%, respectively. The mean effective dose estimate was 6.30 ± 1.7 mSv. Almost perfect agreement between the two readers was found (k = 0.84). Water enema CT can play a role in the diagnosis of bowel endometriosis and represents another accurate potential tool for video laparoscopic approaches, especially in patients for whom MRI is contraindicated. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Prediction of improvement of myocardial wall motion after coronary artery bypass surgery using rest Tl-201/dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Lee, Won Woo; Yeo, Jeong Yeo; Kim, Seok Ki; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul

    1998-01-01

    Using rest Tl-201/ dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), Tl-201 rest perfusion (Rest), Tl-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. In 39 patients (M:F=34:5, age 58±8), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. After bypass surgery, ejection fraction increased from 37.8±9.0% to 45.5±12.3% in 22 patients who had decreased ejectin fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Through univariate logistic regression analysis revealed Rev( p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Among independent predictors obtained by rest Tl-201/stress gated Tc-99m-MIBI/delayed Tl-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor

  20. Dual-energy CT with iodine quantification in distinguishing between bland and neoplastic portal vein thrombosis in patients with hepatocellular carcinoma.

    Science.gov (United States)

    Ascenti, G; Sofia, C; Mazziotti, S; Silipigni, S; D'Angelo, T; Pergolizzi, S; Scribano, E

    2016-09-01

    To investigate the diagnostic accuracy of dual-energy multidetector computed tomography (MDCT) with iodine quantification compared to conventional enhancement measurements in distinguishing bland from neoplastic portal vein thrombosis in patients with hepatocellular carcinoma. Thirty-four patients (26 men, eight women; mean age, 62 years) with hepatocellular carcinoma and portal vein thrombosis underwent contrast-enhanced dual-energy MDCT during the late hepatic arterial phase for the assessment of portal thrombosis (bland, n=21; neoplastic, n=13). Datasets were analysed separately by two different readers. Interobserver correlation and variability were calculated and compared with the Bland-Altman method. Diagnostic accuracy of conventional enhancement measurements and iodine quantification was calculated by setting either histopathology (n=7) or a reference standard based on MDCT imaging criteria and thrombus evolutionary characteristics compared to a previous MDCT examination (n=27). For iodine quantification threshold determination receiver operating characteristic (ROC) curves were drawn. p-Values <0.05 were considered significant. For conventional enhancement measurements and iodine quantification interobserver correlation was 98% and 96%. Enhancement measurement resulted in a sensitivity of 92.3%, specificity of 85.7%, positive predictive value (PPV) of 80%, and negative predictive value (NPV) of 94.7%. An iodine concentration of 0.9 mg/ml optimised discrimination between neoplastic and bland thrombi (area under the ROC [AUC] 0.993) resulting in a sensitivity of 100%, specificity of 95.2%, PPV of 92.9%, and NPV of 100%. The overall diagnostic accuracy of iodine quantification (97%) was significantly better than conventional enhancement measurements (88.2%; p<0.001). Compared to conventional enhancement measurements, iodine quantification improves the characterisation of portal vein thrombi during the late hepatic arterial phase in patients with

  1. Lymph node metastases from head and neck squamous cell carcinoma: MR imaging with ultrasmall superparamagnetic iron oxide particles (Sinerem MR) - results of a phase-III multicenter clinical trial

    International Nuclear Information System (INIS)

    Sigal, R.; Viala, J.; Bosq, J.; Vogl, T.; Mack, M.; Casselman, J.; Depondt, M.; Mattelaer, C.; Moulin, G.; Petit, P.; Champsaur, P.; Veillon, F.; Riehm, S.; Dadashitazehozi, Y.; Hermans, R.; de Jaegere, T.; Marchal, G.; Dubrulle, F.; Chevalier, D.; Lemaitre, L.; Kubiak, C.; Helmberger, R.; Halimi, P.

    2002-01-01

    The aim of this study was to compare the clinical usefulness of ultrasmall superparamagnetic iron oxide (USPIO) MR contrast media (Sinerem, Guerbet Laboratories, Aulnay-sous-Bois, France) with precontrast MRI in the diagnosis of metastatic lymph nodes in patients with head and neck squamous cell carcinoma, using histology as gold standard. Eighty-one previously untreated patients were enrolled in a multicenter phase-III clinical trial. All patients had a noncontrast MR, a Sinerem MR, and surgery within a period of 15 days. The MR exams were analyzed both on site and by two independent radiologists (centralized readers). Correlation between histology and imaging was done per lymph node groups, and per individual lymph nodes when the short axis was ≥10 mm. For individual lymph nodes, Sinerem MR showed a high sensitivity (≥88%) and specificity (≥77%). For lymph node groups, the sensitivity was ≥59% and specificity ≥81%. False-positive results were partially due to inflammatory nodes; false-negative results from the presence of undetected micrometastases. Errors of interpretation were also related to motion and/or susceptibility artifacts and problems of zone assignment. Sinerem MR had a negative predictive value (NPV) ≥90% and a positive predictive value (PPV) ≥51%. The specificity and PPV of Sinerem MR were better than those of precontrast MR. Precontrast MR showed an unexpectedly high sensitivity and NPV which were not increased with Sinerem MR. The potential contribution of Sinerem MR still remains limited by technical problems regarding motion and susceptibility artifacts and spatial resolution. It is also noteworthy that logistical problems, which could reduce the practical value of Sinerem MR, will be minimized in the future since Sinerem MR alone performed as good as the combination of precontrast and Sinerem MR. (orig.)

  2. Lymph node metastases from head and neck squamous cell carcinoma: MR imaging with ultrasmall superparamagnetic iron oxide particles (Sinerem MR) - results of a phase-III multicenter clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Sigal, R.; Viala, J.; Bosq, J. [Department of Radiology, Institut Gustave Roussy, Villejuif (France); Vogl, T.; Mack, M. [Institut fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum, Frankfurt Main (Germany); Casselman, J.; Depondt, M.; Mattelaer, C. [Department of Radiology, Brugge (Belgium); Moulin, G.; Petit, P.; Champsaur, P. [Hopital de la Timone, Marseille (France); Veillon, F.; Riehm, S.; Dadashitazehozi, Y. [Hopital de Hautepierre, Avenue Moliere, 67098 Strasbourg (France); Hermans, R.; de Jaegere, T.; Marchal, G. [Department of Radiology, University Hospitals Gasthuisberg, KU Leuven, Heerestraat 49, 3000 Leuven (Belgium); Dubrulle, F.; Chevalier, D.; Lemaitre, L. [Hopital Huriez, 1 place Verdun, 59037 Lille (France); Kubiak, C.; Helmberger, R.; Halimi, P.

    2002-05-01

    The aim of this study was to compare the clinical usefulness of ultrasmall superparamagnetic iron oxide (USPIO) MR contrast media (Sinerem, Guerbet Laboratories, Aulnay-sous-Bois, France) with precontrast MRI in the diagnosis of metastatic lymph nodes in patients with head and neck squamous cell carcinoma, using histology as gold standard. Eighty-one previously untreated patients were enrolled in a multicenter phase-III clinical trial. All patients had a noncontrast MR, a Sinerem MR, and surgery within a period of 15 days. The MR exams were analyzed both on site and by two independent radiologists (centralized readers). Correlation between histology and imaging was done per lymph node groups, and per individual lymph nodes when the short axis was {>=}10 mm. For individual lymph nodes, Sinerem MR showed a high sensitivity ({>=}88%) and specificity ({>=}77%). For lymph node groups, the sensitivity was {>=}59% and specificity {>=}81%. False-positive results were partially due to inflammatory nodes; false-negative results from the presence of undetected micrometastases. Errors of interpretation were also related to motion and/or susceptibility artifacts and problems of zone assignment. Sinerem MR had a negative predictive value (NPV) {>=}90% and a positive predictive value (PPV) {>=}51%. The specificity and PPV of Sinerem MR were better than those of precontrast MR. Precontrast MR showed an unexpectedly high sensitivity and NPV which were not increased with Sinerem MR. The potential contribution of Sinerem MR still remains limited by technical problems regarding motion and susceptibility artifacts and spatial resolution. It is also noteworthy that logistical problems, which could reduce the practical value of Sinerem MR, will be minimized in the future since Sinerem MR alone performed as good as the combination of precontrast and Sinerem MR. (orig.)

  3. Diagnostic Accuracy of 64Copper Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography for Primary Lymph Node Staging of Intermediate- to High-risk Prostate Cancer: Our Preliminary Experience.

    Science.gov (United States)

    Cantiello, Francesco; Gangemi, Vincenzo; Cascini, Giuseppe Lucio; Calabria, Ferdinando; Moschini, Marco; Ferro, Matteo; Musi, Gennaro; Butticè, Salvatore; Salonia, Andrea; Briganti, Alberto; Damiano, Rocco

    2017-08-01

    To assess the diagnostic accuracy of 64 Copper prostate-specific membrane antigen ( 64 Cu-PSMA) positron emission tomography/computed tomography (PET/CT) in the primary lymph node (LN) staging of a selected cohort of intermediate- to high-risk prostate cancer (PCa) patients. An observational prospective study was performed in 23 patients with intermediate- to high-risk PCa, who underwent 64 Cu-PSMA PET/CT for local and lymph nodal staging before laparoscopic radical prostatectomy with an extended pelvic LN dissection. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for LN status of 64 Cu-PSMA PET/CT were calculated using the final pathological findings as reference. Furthermore, we evaluated the correlation of intraprostatic tumor extent and grading with 64 Cu-PSMA intraprostatic distribution. Pathological analysis of LN involvement in 413 LNs harvested from our study cohort identified a total of 22 LN metastases in 8 (5%) of the 23 (35%) PCa patients. Imaging-based LN staging in a per-patient analysis showed that 64 Cu-PSMA PET/CT was positive in 7 of 8 LN-positive patients (22%) with a sensitivity of 87.5%, specificity of 100%, PPV of 100%, and NPV of 93.7%, considering the maximum standardized uptake value (SUV max ) at 4 hours as our reference. Receiver operating characteristic curve was characterized by an area under the curve of 0.938. A significant positive association was observed between SUV max at 4 hours with Gleason score, index, and cumulative tumor volume. In our intermediate- to high-risk PCa patients study cohort, we showed the high diagnostic accuracy of 64 Cu-PSMA PET/CT for primary LN staging before radical prostatectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Does blood pressure change in treated hypertensive patients depending on whether it is measured by a physician or a nurse?

    Science.gov (United States)

    Coll De Tuero, Gabriel; Sanmartin Albertos, Maria; Vargas Vila, Susanna; Trèmols Iglesias, Susanna; Saez Zafra, Marc; Barceló Rado, Antonia

    2004-01-01

    To determine whether there are differences between blood pressure (BP) measured by the nurse (NBP), BP measured by the physician (PBP) and self-measured BP in treated hypertensive patients and, if found, to evaluate their clinical importance. An observational study is carried out with hypertensive patients recruited from two village-based community health centres in Catalonia (Spain) serving an area with a total population of 2800 inhabitants. All patients treated for hypertension visiting the health centre on a specific day of the week and during the same timetable between October 2000 and May 2001 were included. The difference between physician-systolic BP and nurse-systolic BP was 5.16 mmHg (95% CI 2.62-7.7; pself-measured systolic BP was 4.67 mmHg (95% CI 0.89-8.44; p=0.016). The differences between nurse-systolic BP and self-measured systolic BP were not significant (0.49 mmHg; 95% CI 3.71-2.71; p=0.758). With regards to diastolic BP, no significant differences were found between the different ways of measurement. NBP gave the following values: sensitivity (Sn) of 92% and specificity (Sp) of 60%; positive predictive value (PPV) of 65.7% and negative predictive value (NPV) of 90% with a positive coefficient of probability (CP+) of 2.3 and a negative coefficient of probability (CP-) of 0.133. PBP gave the following results: Sn=72%; Sp=66.7%; PPV=64.3%; NPV=74.1%; CP+=2.16 and CP- = 0.420. Systolic BP measured by the nurse in treated hypertensive patients is significantly lower than the readings obtained by the physician, and are almost identical to ambulatory BP monitoring. Blood pressure determination by the nurse is desirable not only for diagnosis but also to evaluate the level of control of blood pressure during the follow-up of treated hypertensive patients.

  5. Role of specimen US for predicting resection margin status in breast conserving therapy.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G

    2015-01-01

    To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.

  6. Accuracy of MDCT in the preoperative definition of Peritoneal Cancer Index (PCI) in patients with advanced ovarian cancer who underwent peritonectomy and hyperthermic intraperitoneal chemotherapy (HIPEC).

    Science.gov (United States)

    Mazzei, Maria Antonietta; Khader, Leila; Cirigliano, Alfredo; Cioffi Squitieri, Nevada; Guerrini, Susanna; Forzoni, Beatrice; Marrelli, Daniele; Roviello, Franco; Mazzei, Francesco Giuseppe; Volterrani, Luca

    2013-12-01

    To evaluate the accuracy of MDCT in the preoperative definition of Peritoneal Cancer Index (PCI) in patients with advanced ovarian cancer who underwent a peritonectomy and hyperthermic intraperitoneal chemotherapy (HIPEC) after neoadjuvant chemotherapy to obtain a pre-surgery prognostic evaluation and a prediction of optimal cytoreduction surgery. Pre-HIPEC CT examinations of 43 patients with advanced ovarian cancer after neoadjuvant chemotherapy were analyzed by two radiologists. The PCI was scored according to the Sugarbaker classification, based on lesion size and distribution. The results were compared with macroscopic and histologic data after peritonectomy and HIPEC. To evaluate the accuracy of MDCT to detect and localize peritoneal carcinomatosis, both patient-level and regional-level analyses were conducted. A correlation between PCI CT and histologic values for each patient was searched according to the PCI grading. Considering the patient-level analysis, CT shows a sensitivity, specificity, PPV, NPV, and an accuracy in detecting the peritoneal carcinomatosis of 100 %, 40 %, 93 % 100 %, and 93 %, respectively. Considering the regional level analysis, a sensitivity, specificity, PPV, NPV, and diagnostic accuracy of 72 %, 80 %, 66 %, 84 %, and 77 %, respectively were obtained for the correlation between CT and histology. Our results encourage the use of MDCT as the only technique sufficient to select patients with peritoneal carcinomatosis for cytoreductive surgery and HIPEC on the condition that a CT examination will be performed using a dedicated protocol optimized to detect minimal peritoneal disease and CT images will be analyzed by an experienced reader.

  7. Hilar cholangiocarcinoma: MR correlation with surgical and histological findings

    Energy Technology Data Exchange (ETDEWEB)

    Chryssou, E. [MRI Department, Clinical Radiology, St James' s University Hospital, Beckett Street, Leeds LS9 7TF (United Kingdom); Guthrie, J.A., E-mail: ashguthrie@hotmail.co [MRI Department, Clinical Radiology, St James' s University Hospital, Beckett Street, Leeds LS9 7TF (United Kingdom); Ward, J.; Robinson, P.J. [MRI Department, Clinical Radiology, St James' s University Hospital, Beckett Street, Leeds LS9 7TF (United Kingdom)

    2010-10-15

    Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the left main branch of the portal vein (LPV) were 100, 91.6, 93.3, and 100%; and of the right branch of the portal vein (RPV) were 87.5, 100, 100, and 87.5%. The sensitivity, specificity, PPV and NPV of MRI in determining histological involvement of the MPV was 75, 90.9, 60, and 92.5%; 100, 73.3, 73, and 100% for the LPV, and 100, 66.6, 42.8, and 100% for the RPV, respectively. Conclusion: MRC with high-resolution dynamic gadolinium-enhanced MRI is effective in determining tumour extent and vascular involvement, but prior stenting may lead to overestimation.

  8. Hilar cholangiocarcinoma: MR correlation with surgical and histological findings

    International Nuclear Information System (INIS)

    Chryssou, E.; Guthrie, J.A.; Ward, J.; Robinson, P.J.

    2010-01-01

    Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the left main branch of the portal vein (LPV) were 100, 91.6, 93.3, and 100%; and of the right branch of the portal vein (RPV) were 87.5, 100, 100, and 87.5%. The sensitivity, specificity, PPV and NPV of MRI in determining histological involvement of the MPV was 75, 90.9, 60, and 92.5%; 100, 73.3, 73, and 100% for the LPV, and 100, 66.6, 42.8, and 100% for the RPV, respectively. Conclusion: MRC with high-resolution dynamic gadolinium-enhanced MRI is effective in determining tumour extent and vascular involvement, but prior stenting may lead to overestimation.

  9. Detection of feline coronavirus in cerebrospinal fluid for diagnosis of feline infectious peritonitis in cats with and without neurological signs.

    Science.gov (United States)

    Doenges, Stephanie J; Weber, Karin; Dorsch, Roswitha; Fux, Robert; Fischer, Andrea; Matiasek, Lara A; Matiasek, Kaspar; Hartmann, Katrin

    2016-02-01

    The objective of this study was to evaluate the sensitivity and specificity of a real-time reverse transcriptase polymerase chain reaction (real-time RT-PCR) detecting feline coronavirus (FCoV) RNA in cerebrospinal fluid (CSF) of cats with and without neurological and/or ocular signs for the diagnosis of feline infectious peritonitis (FIP). This prospective case-control study included 34 cats. Nineteen cats had a definitive histopathological diagnosis of FIP (seven of these with neurological and/or ocular signs), and 15 cats had other diseases but similar clinical signs (three of these with neurological and/or ocular signs). Real-time RT-PCR was performed on the CSF of all cats, and sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) were calculated. Real-time RT-PCR of CSF showed a specificity of 100% in diagnosing FIP, a sensitivity of 42.1%, a PPV of 100% and an NPV of 57.7%. The sensitivity of the real-time RT-PCR of CSF in cats with neurological and/or ocular signs was 85.7%. Although it is known that RT-PCR can give false positive results, especially if performed using serum or plasma, this real-time RT-PCR detecting FCoV RNA in CSF can be considered a reliable specific tool for the diagnosis of FIP. If only cats with neurological involvement are evaluated, the sensitivity of this real-time RT-PCR in CSF is also high. © ISFM and AAFP 2015.

  10. Correlation between ICDAS and histology: Differences between stereomicroscopy and microradiography with contrast solution as histological techniques.

    Directory of Open Access Journals (Sweden)

    Samara de Azevedo Gomes Campos

    Full Text Available Detection of occlusal caries with visual examination using ICDAS correlates strongly with histology under stereomicroscopy (SM, but dentin aspects under SM are ambiguous regarding mineral content. Thus, our aim was to test two null hypotheses: SM and microradiography result in similar correlations between ICDAS and histology; SM and microradiography result in similar positive (PPV and negative predictive values (NPV of ICDAS cut-off 1-2 (scores 0-2 as sound with histological threshold D3 (demineralization in the inner third of dentin. Occlusal surfaces of extracted permanent teeth (n = 115 were scored using ICDAS. Undemineralized ground sections were histologically scored using both SM without contrast solution and microradiography after immersion in Thoulet's solution 1.47 for 24 h (MRC. Correlation between ICDAS and histology differed from SM (0.782 to MRC (0.511 (p = 0.0002, with a large effect size "q" of 0.49 (95% CI: 0.638/0.338. For ICDAS cut-off 1-2 and D3, PPV from MRC (0.56 was higher than that from SM (0.28 (p< 0.00001; effect size h = 0.81, and NPV from MRC (0.72 was lower than that from SM (1,00 (p < 0.00001; effect size h = 1.58. In conclusion, SM overestimated the correlation between ICDAS and lesion depth, and underestimated the number of occlusal surfaces with ICDAS cut-off 1-2 and deep dentin demineralization.

  11. Phytohormone Signaling of the Resistance to Plum pox virus (PPV, Sharka Disease) Induced by Almond (Prunus dulcis (Miller) Webb) Grafting to Peach (P. persica L. Batsch)

    OpenAIRE

    Azam Nikbakht Dehkordi; Manuel Rubio; Nadali Babaeian; Alfonso Albacete; Pedro Martínez-Gómez

    2018-01-01

    Plum pox virus (PPV, sharka) is a limiting factor for peach production, and no natural sources of resistance have been described. Recent studies, however, have demonstrated that grafting the almond cultivar “Garrigues” onto the “GF305” peach infected with Dideron-type (PPV-D) isolates progressively reduces disease symptoms and virus accumulation. Furthermore, grafting “Garrigues” onto “GF305” prior to PPV-D inoculation has been found to completely prevent virus infection, showing that resista...

  12. Comparison of advanced LWR reactor core design strategies by the net present value method

    International Nuclear Information System (INIS)

    Belac, J.

    2002-12-01

    The following major topics are included: (i) Economic assessment of refuelling variants (Alternatives of economic assessment of refuelling variants; Net present value (NPV); Input parameters accounted for by the economic assessment model; Expressing cash flow for the NPV approach; Specific [unit] costs); (ii) Fuel cycle variants being compared; and (iii) Effect of Czech legislation on the economic indices and NPP fuel cycle assessment. (P.A.)

  13. Perfusion pattern and time of vascularisation with CEUS increase accuracy in differentiating between benign and malignant tumours in 216 musculoskeletal soft tissue masses

    Energy Technology Data Exchange (ETDEWEB)

    De Marchi, Armanda, E-mail: armanda.demarchi@tiscali.it [Department of Imaging, Azienda Ospedaliera Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Prever, Elena Brach del, E-mail: elena.brach@unito.it [Department of OrthopaedicOncology and ReconstructiveSurgery, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Cavallo, Franco, E-mail: franco.cavallo@unito.it [Department of Public health and Paediatrics, University of Turin, Via Santena 5-bis, 10126 Torino (Italy); Pozza, Simona, E-mail: simona.pozza@tin.it [Department of Imaging, Azienda Ospedaliera Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Linari, Alessandra, E-mail: linaralessandra@libero.it [Department of Pathology, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Regina Margherita Hospital, Piazza Polonia, 10126 Torino (Italy); Lombardo, Paolo, E-mail: pao.lombardo82@gmail.com [Department of DiagnosticImaging and Radiotherapy of the University of Turin, Azienda Ospedaliero-Universitaria Città della Salute e della Scienza di Torino, Via Genova 3, 10126 Torino (Italy); Comandone, Alessandro, E-mail: alessandro.comandone@gradenigo.it [Department of Oncology, Gradenigo Hospital, Corso Regina Margherita, 8/10.10153 Torino (Italy); Piana, Raimondo, E-mail: raimondo.piana@libero.it [Department of OrthopaedicOncology and ReconstructiveSurgery, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Faletti, Carlo [Department of Imaging, Azienda Ospedaliera Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy)

    2015-01-15

    Introduction: Musculoskeletal Soft Tissue Tumours (STT) are frequent heterogeneous lesions. Guidelines consider a mass larger than 5 cm and deep with respect to the deep fascia potentially malignant. Contrast Enhanced Ultrasound (CEUS) can detect both vascularity and tumour neoangiogenesis. We hypothesised that perfusion patterns and vascularisation time could improve the accuracy of CEUS in discriminating malignant tumours from benign lesions. Materials and methods: 216 STT were studied: 40% benign lesions, 60% malignant tumours, 56% in the lower limbs. Seven CEUS perfusion patterns and three types of vascularisation (arterial-venous uptake, absence of uptake) were applied. Accuracy was evaluated by comparing imaging with the histological diagnosis. Univariate and multivariate analysis, Chi-square test and t-test for independent variables were applied; significance was set at p < 0.05 level, 95% computed CI. Results: CEUS pattern 6 (inhomogeneous perfusion), arterial uptake and location in the lower limb were associated with high risk of malignancy. CEUS pattern has PPV 77%, rapidity of vascularisation PPV 69%; location in the limbs is the most sensitive indicator, but NPV 52%, PPV 65%. The combination of CEUS-pattern and vascularisation has 74% PPV, 60% NPV, 70% sensitivity. No correlation with size and location in relation to the deep fascia was found. Conclusion: US with CEUS qualitative analysis could be an accurate technique to identify potentially malignant STT, for which second line imaging and biopsy are indicated in Referral Centers. Intense inhomogeneous enhancement with avascular areas and rapid vascularisation time could be useful in discriminating benign from malignant SST, overall when the lower limbs are involved.

  14. Underreporting of nursing home utilization on the CMS-2728 in older incident dialysis patients and implications for assessing mortality risk.

    Science.gov (United States)

    Bowling, C Barrett; Zhang, Rebecca; Franch, Harold; Huang, Yijian; Mirk, Anna; McClellan, William M; Johnson, Theodore M; Kutner, Nancy G

    2015-03-21

    The usage of nursing home (NH) services is a marker of frailty among older adults. Although the Centers for Medicare & Medicaid Services (CMS) revised the Medical Evidence Report Form CMS-2728 in 2005 to include data collection on NH institutionalization, the validity of this item has not been reported. There were 27,913 patients ≥ 75 years of age with incident end-stage renal disease (ESRD) in 2006, which constituted our analysis cohort. We determined the accuracy of the CMS-2728 using a matched cohort that included the CMS Minimum Data Set (MDS) 2.0, often employed as a "gold standard" metric for identifying patients receiving NH care. We calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the CMS-2728 NH item. Next, we compared characteristics and mortality risk by CMS-2728 and MDS NH status agreement. The sensitivity, specificity, PPV and NPV of the CMS-2728 for NH status were 33%, 97%, 80% and 79%, respectively. Compared to those without the MDS or CMS-2728 NH indicator (No MDS/No 2728), multivariable adjusted hazard ratios (95% confidence interval) for mortality associated with NH status were 1.55 (1.46 - 1.64) for MDS/2728, 1.48 (1.42 - 1.54) for MDS/No 2728, and 1.38 (1.25 - 1.52) for No MDS/2728. NH utilization was more strongly associated with mortality than other CMS-2728 items in the model. The CMS-2728 underestimated NH utilization among older adults with incident ESRD. The potential for misclassification may have important ramifications for assessing prognosis, developing advanced care plans and providing coordinated care.

  15. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  16. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  17. Comparative analysis of {sup 99m}Tc-MDP three-phase bone scan with SPECT/CT and {sup 99m}Tc-HMPAO-labeled WBC SPECT/CT in the differential diagnosis of clinically suspicious post-traumatic osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Chan Woo; Lee, Soo Jin; Kim, Ji Young; Hwang, Kyu Tae; Choi, Yun Young [Hanyang University Medical CenterSeoul (Korea, Republic of)

    2017-03-15

    To identify differences between three-phase bone scan and SPECT/CT (TBS) and WBC SPECT/CT (WS) and compare diagnostic accuracies of each modality in patients with suspicious post-traumatic osteomyelitis (OM). Twenty-one patients with suspicious post-traumatic OM were enrolled. All patients performed TBS and WS within 1 week. Foci of MDP and WBC accumulation were divided into three categories: bone (OM), soft tissue (soft tissue inflammation; STI), negative for inflammation (NI). Confirmative diagnosis was made upon operative pathology or long-term clinical follow-up. Of 21 patients, four OM, eight STI, nine NI were finally diagnosed. TBS diagnosis was correct in three of four positive cases and nine of 17 negative cases. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV) of TBS were 75 %, 52.9 %, 57.1 %, 27.3 %, 90 %. WS diagnosis was correct in two of four positive cases and 17 of 17 negative cases. Sensitivity, specificity, accuracy, PPV, NPV were 50 %, 100 %, 81.0 %, 100 %, 89.5 %. Twelve of 21 cases showed agreement between TBS and WS. TBS misdiagnosed nine cases (six STI and two NI as eight OM; one OM as one STI), while WS misdiagnosed four cases (two OM as two STI; two STI as two NI). Combining results from TBS and WS led to better diagnostic accuracy (91.7 %) than either TBS or WS alone. TBS and WS showed moderate agreement in assessment of clinically suspected post-traumatic OM. WS better evaluated inflammation than TBS. WS tended to underestimate inflammation whereas TBS tended to overestimate inflammation. Combining TBS and WS enhanced diagnostic accuracy.

  18. A study of interpolation method in diagnosis of carpal tunnel syndrome

    Directory of Open Access Journals (Sweden)

    Alireza Ashraf

    2013-01-01

    Full Text Available Context: The low correlation between the patients′ signs and symptoms of carpal tunnel syndrome (CTS and results of electrodiagnostic tests makes the diagnosis challenging in mild cases. Interpolation is a mathematical method for finding median nerve conduction velocity (NCV exactly at carpal tunnel site. Therefore, it may be helpful in diagnosis of CTS in patients with equivocal test results. Aim: The aim of this study is to evaluate interpolation method as a CTS diagnostic test. Settings and Design: Patients with two or more clinical symptoms and signs of CTS in a median nerve territory with 3.5 ms ≤ distal median sensory latency <4.6 ms from those who came to our electrodiagnostic clinics and also, age matched healthy control subjects were recruited in the study. Materials and Methods: Median compound motor action potential and median sensory nerve action potential latencies were measured by a MEDLEC SYNERGY VIASIS electromyography and conduction velocities were calculated by both routine method and interpolation technique. Statistical Analysis Used: Chi-square and Student′s t-test were used for comparing group differences. Cut-off points were calculated using receiver operating characteristic curve. Results: A sensitivity of 88%, specificity of 67%, positive predictive value (PPV and negative predictive value (NPV of 70.8% and 84.7% were obtained for median motor NCV and a sensitivity of 98.3%, specificity of 91.7%, PPV and NPV of 91.9% and 98.2% were obtained for median sensory NCV with interpolation technique. Conclusions: Median motor interpolation method is a good technique, but it has less sensitivity and specificity than median sensory interpolation method.

  19. Telepsychiatry clinical decision support system used by non-psychiatrists in remote areas: Validity & reliability of diagnostic module

    Science.gov (United States)

    Malhotra, Savita; Chakrabarti, Subho; Shah, Ruchita; Sharma, Minali; Sharma, Kanu Priya; Malhotra, Akanksha; Upadhyaya, Suneet K.; Margoob, Mushtaq A.; Maqbool, Dar; Jassal, Gopal D.

    2017-01-01

    Background & objectives: A knowledge-based, logically-linked online telepsychiatric decision support system for diagnosis and treatment of mental disorders was developed and validated. We evaluated diagnostic accuracy and reliability of the application at remote sites when used by non-psychiatrists who underwent a brief training in its use through video-conferencing. Methods: The study was conducted at a nodal telepsychiatry centre, and three geographically remote peripheral centres. The diagnostic tool of application had a screening followed by detailed criteria-wise diagnostic modules for 18 psychiatric disorders. A total of 100 consecutive consenting adult outpatients attending remote telepsychiatry centres were included. To assess inter-rater reliability, patients were interviewed face to face by non-specialists at remote sites using the application (active interviewer) and simultaneously on online application via video-conferencing by a passive assessor at nodal centre. Another interviewer at the nodal centre rated the patient using Mini-International Neuropsychiatric Interview (MINI) for diagnostic validation. Results: Screening sub-module had high sensitivity (80-100%), low positive predictive values (PPV) (0.10-0.71) but high negative predictive value (NPV) (0.97-1) for most disorders. For the diagnostic sub-modules, Cohen's kappa was >0.4 for all disorders, with kappa of 0.7-1.0 for most disorders. PPV and NPV were high for most disorders. Inter-rater agreement analysis revealed kappa >0.6 for all disorders. Interpretation & conclusions: Diagnostic tool showed acceptable to good validity and reliability when used by non-specialists at remote sites. Our findings show that diagnostic tool of the telepsychiatry application has potential to empower non-psychiatrist doctors and paramedics to diagnose psychiatric disorders accurately and reliably in remote sites. PMID:29265020

  20. Differentiation of residual/recurrent gliomas from postradiation necrosis with arterial spin labeling and diffusion tensor magnetic resonance imaging-derived metrics

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Razek, Ahmed Abdel Khalek; El-Serougy, Lamiaa; Gaballa, Gada; Talaat, Mona [Mansoura Faculty of Medicine, Department of Diagnostic Radiology, Mansoura (Egypt); Abdelsalam, Mohamed [Mansoura Faculty of Medicine, Department of Neurology, Mansoura (Egypt)

    2018-02-15

    The aim of this study is to differentiate recurrent/residual gliomas from postradiation changes using arterial spin labeling (ASL) perfusion and diffusion tensor imaging (DTI)-derived metrics. Prospective study was conducted upon 42 patients with high-grade gliomas after radiotherapy only or prior to other therapies that underwent routine MR imaging, ASL, and DTI. The tumor blood flow (TBF), fractional anisotropy (FA), and mean diffusivity (MD) of the enhanced lesion and related edema were calculated. The lesion was categorized as recurrence/residual or postradiation changes. There was significant differences between residual/recurrent gliomas and postradiation changes of TBF (P = 0.001), FA (P = 0.001 and 0.04), and MD (P = 0.001) of enhanced lesion and related edema respectively. The area under the curve (AUC) of TBF of enhanced lesion and related edema used to differentiate residual/recurrent gliomas from postradiation changes were 0.95 and 0.93 and of MD were 0.95 and 0.81 and of FA were 0.81 and 0.695, respectively. Combined ASL and DTI metrics of the enhanced lesion revealed AUC of 0.98, accuracy of 95%, sensitivity of 93.8%, specificity of 95.8%, positive predictive value (PPV) of 93.8%, and negative predictive value (NPV) of 95.8%. Combined metrics of ASL and DTI of related edema revealed AUC of 0.97, accuracy of 92.5%, sensitivity of 93.8%, specificity of 91.7%, PPV of 88.2%, and NPV of 95.7. Combined ASL and DTI metrics of enhanced lesion and related edema are valuable noninvasive tools in differentiating residual/recurrent gliomas from postradiation changes. (orig.)

  1. Lack of pupil reflex and loss of consciousness predict 30-day neurological sequelae in patients with carbon monoxide poisoning.

    Directory of Open Access Journals (Sweden)

    Jian-Fang Zou

    Full Text Available Predicting the neurological sequelae of carbon monoxide poisoning (COP has not been well studied. We investigated the independent predictors of neurological sequelae in patients with COP and combined these predictors to predict the prognosis.This study was conducted at four hospitals in Shandong Province, China. Data were retrospectively collected from 258 patients with COP between November 1990 and October 2011. Thirty-day neurological sequelae were the primary endpoints.A lack of pupil reflex and a loss of consciousness appear to be independent predictors for neurological sequelae in patients with COP. The presence of either one had a sensitivity of 77.0% (95% confidence interval [CI]: 69.3-83.2, a specificity of 47.1% (95% CI: 38.3-56.0, positive predictive value (PPV of 62.9% (95% CI: 55.2-70.1, and a negative predictive value (NPV of 63.6% (95% CI: 52.6-73.4. With both predictors present, the sensitivity was 11.5% (95% CI: 6.9 to 18.3, the specificity was 99.2 (95% CI: 94.7-100.0, the PPV was 94.1% (95% CI: 69.2-99.7, and the NPV was 49.0% (95% CI: 42.5-55.5.The risk for neurological sequelae apparently increased with the number of independent predictors. In patients with both predictors, the risk for neurological sequelae was 94.1%. Almost all (99.2% patients with neither predictor had no neurological sequelae. This finding may help physicians make decisions about and dispositions for patients with COP. For patients with a higher risk, earlier treatment and more appropriate utilization of health care services, including hyperbaric oxygen, should be considered.

  2. Pharmacogenetic testing prior to carbamazepine treatment of epilepsy: patients' and physicians' preferences for testing and service delivery.

    Science.gov (United States)

    Powell, Graham; Holmes, Emily A F; Plumpton, Catrin O; Ring, Adele; Baker, Gus A; Jacoby, Ann; Pirmohamed, Munir; Marson, Anthony G; Hughes, Dyfrig A

    2015-11-01

    Pharmacogenetic studies have identified the presence of the HLA-A*31:01 allele as a predictor of cutaneous adverse drugs reactions (ADRs) to carbamazepine. This study aimed to ascertain the preferences of patients and clinicians to inform carbamazepine pharmacogenetic testing services. Attributes of importance to people with epilepsy and neurologists were identified through interviews and from published sources. Discrete choice experiments (DCEs) were conducted in 82 people with epilepsy and 83 neurologists. Random-effects logit regression models were used to determine the importance of the attributes and direction of effect. In the patient DCE, all attributes (seizure remission, reduction in seizure frequency, memory problems, skin rash and rare, severe ADRs) were significant. The estimated utility of testing was greater, at 0.52 (95% CI 0.19, 1.00) than not testing at 0.33 (95% CI -0.07, 0.81). In the physician DCE, cost, inclusion in the British National Formulary, coverage, negative predictive value (NPV) and positive predictive value (PPV) were significant. Marginal rates of substitution indicated that neurologists were willing to pay £5.87 for a 1 percentage point increase in NPV and £3.99 for a 1 percentage point increase in PPV. The inclusion of both patients' and clinicians' perspectives represents an important contribution to the understanding of preferences towards pharmacogenetic testing prior to initiating carbamazepine. Both groups identified different attributes but had generally consistent preferences. Patients' acceptance of a decrease in treatment benefit for a reduced chance of severe ADRs adds support for the implementation of HLA-A*31:01 testing in routine practice. © 2015 The British Pharmacological Society.

  3. Coding of obesity in administrative hospital discharge abstract data: accuracy and impact for future research studies.

    Science.gov (United States)

    Martin, Billie-Jean; Chen, Guanmin; Graham, Michelle; Quan, Hude

    2014-02-13

    Obesity is a pervasive problem and a popular subject of academic assessment. The ability to take advantage of existing data, such as administrative databases, to study obesity is appealing. The objective of our study was to assess the validity of obesity coding in an administrative database and compare the association between obesity and outcomes in an administrative database versus registry. This study was conducted using a coronary catheterization registry and an administrative database (Discharge Abstract Database (DAD)). A Body Mass Index (BMI) ≥30 kg/m2 within the registry defined obesity. In the DAD obesity was defined by diagnosis codes E65-E68 (ICD-10). The sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of an obesity diagnosis in the DAD was determined using obesity diagnosis in the registry as the referent. The association between obesity and outcomes was assessed. The study population of 17380 subjects was largely male (68.8%) with a mean BMI of 27.0 kg/m2. Obesity prevalence was lower in the DAD than registry (2.4% vs. 20.3%). A diagnosis of obesity in the DAD had a sensitivity 7.75%, specificity 98.98%, NPV 80.84% and PPV 65.94%. Obesity was associated with decreased risk of death or re-hospitalization, though non-significantly within the DAD. Obesity was significantly associated with an increased risk of cardiac procedure in both databases. Overall, obesity was poorly coded in the DAD. However, when coded, it was coded accurately. Administrative databases are not an optimal datasource for obesity prevalence and incidence surveillance but could be used to define obese cohorts for follow-up.

  4. Prenatal Diagnosis of Congenital Cytomegalovirus Infection

    Science.gov (United States)

    Lazzarotto, T.; Guerra, B.; Spezzacatena, P.; Varani, S.; Gabrielli, L.; Pradelli, P.; Rumpianesi, F.; Banzi, C.; Bovicelli, L.; Landini, M. P.

    1998-01-01

    We report here the results of a study on the prenatal diagnosis of congenital cytomegalovirus (CMV) infection. The study was carried out by both PCR and virus isolation from amniotic fluid (AF) for 82 pregnant women at risk of transmitting CMV for the detection of (i) seroconversion to CMV immunoglobulin G (IgG) positivity during the first trimester of pregnancy, (ii) symptomatic CMV infection in the mother during the first trimester of pregnancy or intrauterine growth retardation detected by ultrasound or abnormal ultrasonographic findings suggestive of fetal infections, and (iii) seropositivity for CMV-specific IgM. For 50 women, fetal blood (FB) was also obtained and tests for antigenemia and PCR were performed. The results indicate that AF is better than FB for the prenatal diagnosis of CMV infection. PCR with AF has a sensitivity (SNS) of 100%, a specificity (SPE) of 83.3%, a positive predictive value (PPV) of 40%, and a negative predictive value (NPV) of 100%; rapid virus isolation with the same material has an SNS of 50%, an SPE of 100%, a PPV of 100%, and an NPV of 94.7%. Fewer than 10% of the women positive for IgM by enzyme immunoassay (EIA) had a congenitally infected fetus or newborn infant. When EIA IgM positivity was confirmed by Western blotting (WB) and the WB profile was considered, the percent transmission detected among women with an “at-risk” profile was higher than that observed among IgM-positive women and was the same as that among women who seroconverted during the first trimester of pregnancy (transmission rates of 29 and 25%, respectively). PMID:9817869

  5. Sperm associated antigen 9 (SPAG9) expression and humoral response in benign and malignant salivary gland tumors

    Science.gov (United States)

    Agarwal, Sumit; Parashar, Deepak; Gupta, Namita; Jagadish, Nirmala; Thakar, Alok; Suri, Vaishali; Kumar, Rajive; Gupta, Anju; Ansari, Abdul S; Lohiya, Nirmal Kumar; Suri, Anil

    2015-01-01

    Salivary gland cancers are highly aggressive epithelial tumor associated with metastatic potential and high mortality. The tumors are biologically diverse and are of various histotypes. Besides, the detection and diagnosis is a major problem of salivary gland cancer for available treatment modalities. In the present study, we have investigated the association of sperm associated antigen 9 (SPAG9) expression with salivary gland tumor (SGT). Clinical specimens of benign (n = 16) and malignant tumors (n = 86) were examined for the SPAG9 expression. In addition, the sera and adjacent non-cancerous tissues (n = 72) from available patients were obtained. Our in situ RNA hybridization and immunohistochemistry (IHC) analysis revealed significant difference (p = 0.0001) in SPAG9 gene and protein expression in benign (63%) and malignant tumor (84%) specimens. Further, significant association was also observed between SPAG9 expression and malignant tumors (P = 0.05). A cut-off value of >10% cells expressing SPAG9 protein designated as positive in IHC, predicted presence of malignant SGT with 83.72% sensitivity, 100% specificity, 100% PPV and 83.72% NPV. Humoral response against SPAG9 protein was generated in 68% of SGT patients. A cut-off value of 0.212 OD for anti-SPAG9 antibodies in ELISA predicted presence of malignant SGT with 69.23% sensitivity, 100% specificity, 100% PPV and 78.94% NPV. Collectively, our data suggests that the majority of SGT show significant difference and association among benign and malignant tumors for SPAG9 gene and protein expression and also exhibit humoral response against SPAG9 protein. Hence, SPAG9 may be developed as a biomarker for detection and diagnosis of salivary gland tumors. PMID:25941602

  6. Adult "termination-of-resuscitation" (TOR)-criteria may not be suitable for children - a retrospective analysis.

    Science.gov (United States)

    Rotering, Victoria Maria; Trepels-Kottek, Sonja; Heimann, Konrad; Brokmann, Jörg-Christian; Orlikowsky, Thorsten; Schoberer, Mark

    2016-12-07

    Only a small number of patients survive out-of-hospital-cardiac-arrest (OHCA). The duration of CPR varies considerably and transportation of patients under CPR is often unsuccessful. Termination-of-resuscitation (TOR)-criteria aim to preclude futile resuscitation efforts. Our goal was to find out to which extent existing TOR-criteria can be transferred to paediatric OHCA-patients with special regard to their prognostic value. We performed a retrospective analysis of an eleven-year single centre patient cohort. 43 paediatric patients admitted to our institution after emergency-medical-system (EMS)-confirmed OHCA from 2003 to 2013 were included. Morrison's BLS- and ALS-TOR-rules as well as the Trauma-TOR-criteria by the American Association of EMS Physicians were evaluated for application in children, by calculating sensitivity, specificity, negative and positive predictive value for death-, as well as survival-prediction in our cohort. 26 patients achieved ROSC and 14 were discharged alive (n = 7 PCPC 1/2, n = 7 PCPC 5). Sensitivity for BLS-TOR-criteria predicting death was 48.3%, specificity 92.9%, the PPV 93.3% and the NPV 46.4%. ALS-TOR-criteria for death had a sensitivity of 10.3%, specificity of 100%, a PPV of 100% and an NPV of 35%. Retrospective application of the BLS-TOR-rule in our patient cohort identified the resuscitation of one later survivor as futile. ALS-TOR-criteria did not give false predictions of death. The proportion of CPRs that could have been abandoned is 48.2% for the BLS-TOR and only 10.3% for the ALS-TOR-rule. Both rules therefore appear not to be transferable to a paediatric population.

  7. The RIPASA score for the diagnosis of acute appendicitis: A comparison with the modified Alvarado score.

    Science.gov (United States)

    Díaz-Barrientos, C Z; Aquino-González, A; Heredia-Montaño, M; Navarro-Tovar, F; Pineda-Espinosa, M A; Espinosa de Santillana, I A

    2018-02-06

    Acute appendicitis is the first cause of surgical emergencies. It is still a difficult diagnosis to make, especially in young persons, the elderly, and in reproductive-age women, in whom a series of inflammatory conditions can have signs and symptoms similar to those of acute appendicitis. Different scoring systems have been created to increase diagnostic accuracy, and they are inexpensive, noninvasive, and easy to use and reproduce. The modified Alvarado score is probably the most widely used and accepted in emergency services worldwide. On the other hand, the RIPASA score was formulated in 2010 and has greater sensitivity and specificity. There are very few studies conducted in Mexico that compare the different scoring systems for appendicitis. The aim of our article was to compare the modified Alvarado score and the RIPASA score in the diagnosis of patients with abdominal pain and suspected acute appendicitis. An observational, analytic, and prolective study was conducted within the time frame of July 2002 and February 2014 at the Hospital Universitario de Puebla. The questionnaires used for the evaluation process were applied to the patients suspected of having appendicitis. The RIPASA score with 8.5 as the optimal cutoff value: ROC curve (area .595), sensitivity (93.3%), specificity (8.3%), PPV (91.8%), NPV (10.1%). Modified Alvarado score with 6 as the optimal cutoff value: ROC curve (area .719), sensitivity (75%), specificity (41.6%), PPV (93.7%), NPV (12.5%). The RIPASA score showed no advantages over the modified Alvarado score when applied to patients presenting with suspected acute appendicitis. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  8. Controlling morphology and chain aggregation in semiconducting conjugated polymers: the role of solvent on optical gain in MEH-PPV.

    Science.gov (United States)

    Lampert, Zach E; Reynolds, C Lewis; Papanikolas, John M; Aboelfotoh, M Osama

    2012-10-25

    We report the results of a detailed investigation that addresses the influence of polymer morphology and chain aggregation, as controlled by the chemical nature of the solvent, on the optical gain properties of the conjugated polymer poly[2-methoxy-5-(2'-ethylhexyloxy)-p-phenylene vinylene] (MEH-PPV). Using the variable stripe length technique in the picosecond regime, we have extensively studied the optical gain performance of asymmetric planar waveguides formed with thin MEH-PPV films spin-cast from concentrated chlorobenzene (CB) and tetrahydrofuran (THF) solutions onto thermally oxidized silicon substrates. CB and THF solvents were chosen based on their known ability to promote and effectively limit aggregate formation, respectively. Very large net gain coefficients are demonstrated, reaching values of 330 and 365 cm(-1), respectively, when optically pumping the waveguides with a maximum energy density of 85 μJ/cm(2). Our results clearly demonstrate that polymer morphology, and hence, the chain conformation dependence of the degree of aggregation in the films as controlled by the solvent, has minimal impact on the net gain. Moreover, the waveguides exhibit low loss coefficients of 10-20 cm(-1) at the ASE wavelength. These results question the importance of polymer morphology and aggregate formation in polymer-based optical devices operating at high excitation densities in the stimulated emission regime as would be characteristic of lasers and optical amplifiers.

  9. Phytohormone Signaling of the Resistance to Plum pox virus (PPV, Sharka Disease) Induced by Almond (Prunus dulcis (Miller) Webb) Grafting to Peach (P. persica L. Batsch).

    Science.gov (United States)

    Dehkordi, Azam Nikbakht; Rubio, Manuel; Babaeian, Nadali; Albacete, Alfonso; Martínez-Gómez, Pedro

    2018-05-03

    Plum pox virus (PPV, sharka) is a limiting factor for peach production, and no natural sources of resistance have been described. Recent studies, however, have demonstrated that grafting the almond cultivar "Garrigues" onto the "GF305" peach infected with Dideron-type (PPV-D) isolates progressively reduces disease symptoms and virus accumulation. Furthermore, grafting "Garrigues" onto "GF305" prior to PPV-D inoculation has been found to completely prevent virus infection, showing that resistance is constitutive and not induced by the virus. To unravel the phytohormone signaling of this mechanism, we analyzed the following phytohormones belonging to the principal hormone classes: the growth-related phytohormones cytokinin trans-zeatin (tZ) and the gibberellins GA₃ and GA₄; and the stress-related phytohormones ethylene acid precursor 1-aminocyclopropane-1-carboxylic acid (ACC), abscisic acid (ABA), salicylic acid (SA), and jasmonic acid (JA). PPV inoculation produced a significant increase in GA₃ and ABA in peach, and these imbalances were related to the presence of chlorosis symptoms. However, grafting "Garrigues" almond onto the PPV-inoculated "GF305" peach produced the opposite effect, reducing GA₃ and ABA contents in parallel to the elimination of symptoms. Our results showed the significant implication of SA in this induced resistance in peach with an additional effect on tZ and JA concentrations. This SA-induced resistance based in the decrease in symptoms seems to be different from Systemic Acquired Resistance (SAR) and Induced Systemic Resistance (ISR), which are based in other reactions producing necrosis. Further studies are necessary, however, to validate these results against PPV-D isolates in the more aggressive Marcus-type (PPV-M) isolates.

  10. Uncertainty in Forest Net Present Value Estimations

    Directory of Open Access Journals (Sweden)

    Ilona Pietilä

    2010-09-01

    Full Text Available Uncertainty related to inventory data, growth models and timber price fluctuation was investigated in the assessment of forest property net present value (NPV. The degree of uncertainty associated with inventory data was obtained from previous area-based airborne laser scanning (ALS inventory studies. The study was performed, applying the Monte Carlo simulation, using stand-level growth and yield projection models and three alternative rates of interest (3, 4 and 5%. Timber price fluctuation was portrayed with geometric mean-reverting (GMR price models. The analysis was conducted for four alternative forest properties having varying compartment structures: (A a property having an even development class distribution, (B sapling stands, (C young thinning stands, and (D mature stands. Simulations resulted in predicted yield value (predicted NPV distributions at both stand and property levels. Our results showed that ALS inventory errors were the most prominent source of uncertainty, leading to a 5.1–7.5% relative deviation of property-level NPV when an interest rate of 3% was applied. Interestingly, ALS inventory led to significant biases at the property level, ranging from 8.9% to 14.1% (3% interest rate. ALS inventory-based bias was the most significant in mature stand properties. Errors related to the growth predictions led to a relative standard deviation in NPV, varying from 1.5% to 4.1%. Growth model-related uncertainty was most significant in sapling stand properties. Timber price fluctuation caused the relative standard deviations ranged from 3.4% to 6.4% (3% interest rate. The combined relative variation caused by inventory errors, growth model errors and timber price fluctuation varied, depending on the property type and applied rates of interest, from 6.4% to 12.6%. By applying the methodology described here, one may take into account the effects of various uncertainty factors in the prediction of forest yield value and to supply the

  11. Relation between exciplex formation and photovoltaic properties of PPV polymer-based blends

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Chunhong; Neher, Dieter [Institute of Physics, University of Potsdam, Am Neuen Palais 10, 14469 Potsdam (Germany); Kietzke, Thomas [Institute of Physics, University of Potsdam, Am Neuen Palais 10, 14469 Potsdam (Germany); Institute of Materials Research and Engineering (IMRE), Research Link 3, 117602 Singapore (Singapore); Kumke, Michael [Institute of Chemistry, University of Potsdam, Karl-Liebknecht-Street 24-25, 14476 Golm (Germany); Hoerhold, Hans-Heinrich [Institute of Organic Chemistry and Macromolecular Chemistry, University of Jena, Humboldtstr. 10, 07743 Jena (Germany)

    2007-03-06

    As a new record for pure polymer-blend solar cells, an energy conversion efficiency (ECE) of 1.7% was recently achieved for M3EH-PPV:CN-ether-PPV (Poly[oxa-1,4-phenylene-1,2-(1-cyano)-ethylene-2,5-dioctyloxy-1,4-phenylene-1,2- (2-cyano)-ethylene-1,4-phenylene]) based devices [T. Kietzke, H.-H. Hoerhold, D. Neher, Chem. Mater. 17 (2005) 6532]. Even though that photoluminescence experiments indicated that 95% of the photogenerated excitions were dissociated in the blend, the external quantum efficiency reached only 31%. Thus more than 2/3 of the dissociated excitons were lost for the energy conversion. In order to identify the processes which limit the photovoltaic efficiency of polymer-blend solar cells, studies on the steady state and time-resolved photoluminescence of the individual polymer and polymer blend were performed. In the polymer-blend layer, we observed a considerable long-wavelength emission due to exciplex formation. The exciplex emission can be reduced by thermal annealing. At the same time the IPCE of the blend-based device increased, indicating a more efficient generation of free-charge carriers. These findings lead to the conclusion that charge-carrier recombination via exciplex formation constitutes one of the loss channels which limits the efficiency of polymer solar cells. (author)

  12. Number of colony forming units in urine at 35–37 weeks’ gestation as predictor of the vaginal load of Group B Streptococci at birth

    DEFF Research Database (Denmark)

    Khalil, Mohammad; Bak Thorsen, Poul; Møller, Jens Kjølseth

    2018-01-01

    prophylaxis; NPV, Negative predictive value; PCR, Polymerase chain reaction; PPV, Positive predictive value Keywords Group B Streptococcus bacteriuria; Colony count; Vaginal colonization; Risk factor; Intrapartum colonization; Early-onset neonatal infection; Intrapartum antibiotic prophylaxis...... at 35-37 weeks’ gestation. Outcome was vaginal GBS colonization at birth as assessed by a semi-quantitative culture of a vaginal swab sample (negative, +1, +2, +3). Results Bacteriuria with GBS at 35-37 weeks’ gestation performed with a sensitivity of 30% concerning any degree of vaginal GBS...... colonization at birth (31 of 104 cases); 19% for light (+1), 17% for medium (+2), and 52% for high load (+3) vaginal GBS colonization. The colony count in case of GBS bacteriuria at 35-37 weeks’ gestation performed with positive predictive values of 35% for 104 CFU...

  13. Average Costs versus Net Present Value

    NARCIS (Netherlands)

    E.A. van der Laan (Erwin); R.H. Teunter (Ruud)

    2000-01-01

    textabstractWhile the net present value (NPV) approach is widely accepted as the right framework for studying production and inventory control systems, average cost (AC) models are more widely used. For the well known EOQ model it can be verified that (under certain conditions) the AC approach gives

  14. Performance of two strategies for urgent ANCA and anti-GBM analysis in vasculitis.

    Science.gov (United States)

    de Joode, Anoek A E; Roozendaal, Caroline; van der Leij, Marcel J; Bungener, Laura B; Sanders, Jan Stephan F; Stegeman, Coen A

    2014-02-01

    In anti-neutrophil cytoplasmic antibodies (ANCA) associated small vessel vasculitis (AAV), rapid testing for ANCA and anti-glomerular basement membrane (GBM) antibodies may be beneficial for therapeutic purpose. We analysed the diagnostic performance of two rapid ANCA and anti-GBM test methods in 260 patients with suspected AAV. Between January 2004 and November 2010, we analysed 260 samples by qualitative Dotblot (Biomedical Diagnostics); retrospective analysis followed with directly coated highly sensitive automated Phadia ELiA and ELiA anti-GBM. Results were related to the final clinical diagnosis and compared with routine capture ELISA. Seventy-four patients had a final diagnosis of AAV (n=62) or anti-GBM disease (n=12). Both Dotblot and ELiA detected all 12 cases of anti-GBM disease; 2 false positive results were found. Dotblot detected ANCA in 56 of 62 AAV patients (sensitivity 90%, NPV 97%), and showed 5 false positives (specificity 97%, PPV 90%). The Phadia ELiA anti-PR3(s) or anti-MPO(s) was positive in 57 of 62 AAV patients (sensitivity 92%, NPV 97%), and had 5 false positives (specificity 97%, PPV 88%). Routine capture ELISA was equally accurate (sensitivity 94%, specificity 97%, PPV 88%, NPV 98%). The Dotblot and Phadia ELiA on anti-GBM, anti-PR3(s) and anti-MPO(s) performed excellently; results were almost identical to routine ELISA. When suspicion of AAV or anti-GBM disease is high and diagnosis is urgently needed, both tests are very powerful for rapid serological diagnosis. Further studies have to confirm the test performances in samples routinely presented for ANCA testing and in follow-up of positive patients. Copyright © 2013 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  15. Diagnosis of drowning using post-mortem computed tomography based on the volume and density of fluid accumulation in the maxillary and sphenoid sinuses.

    Science.gov (United States)

    Kawasumi, Yusuke; Kawabata, Tomoyoshi; Sugai, Yusuke; Usui, Akihito; Hosokai, Yoshiyuki; Sato, Miho; Saito, Haruo; Ishibashi, Tadashi; Hayashizaki, Yoshie; Funayama, Masato

    2013-10-01

    Recent studies have reported that drowning victims frequently have fluid accumulation in the paranasal sinuses, most notably the maxillary and sphenoid sinuses. However, in our previous study, many non-drowning victims also had fluid accumulation in the sinuses. Therefore, we evaluated the qualitative difference in fluid accumulation between drowning and non-drowning cases in the present study. Thirty-eight drowning and 73 non-drowning cases were investigated retrospectively. The fluid volume and density of each case were calculated using a DICOM workstation. The drowning cases were compared with the non-drowning cases using the Mann-Whitney U-test because the data showed non-normal distribution. The median fluid volume was 1.82 (range 0.02-11.7) ml in the drowning cases and 0.49 (0.03-8.7) ml in the non-drowning cases, and the median fluid density was 22 (-14 to 66) and 39 (-65 to 77) HU, respectively. Both volume and density differed significantly between the drowning and non-drowning cases (p=0.001, p=0.0007). Regarding cut-off levels in the ROC analysis, the points on the ROC curve closest (0, 1) were 1.03ml (sensitivity 68%, specificity 68%, PPV 53%, NPV 81%) and 27.5 HU (61%, 70%, 51%, 77%). The Youden indices were 1.03ml and 37.8 HU (84%, 51%, 47%, 86%). When the cut-off level was set at 1.03ml and 27.5HU, the sensitivity was 42%, specificity 45%, PPV 29% and NPV 60%. When the cut-off level was set at 1.03ml and 37.8HU, sensitivity was 58%, specificity 32%, PPV 31% and NPV 59%. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Phytohormone Signaling of the Resistance to Plum pox virus (PPV, Sharka Disease Induced by Almond (Prunus dulcis (Miller Webb Grafting to Peach (P. persica L. Batsch

    Directory of Open Access Journals (Sweden)

    Azam Nikbakht Dehkordi

    2018-05-01

    Full Text Available Plum pox virus (PPV, sharka is a limiting factor for peach production, and no natural sources of resistance have been described. Recent studies, however, have demonstrated that grafting the almond cultivar “Garrigues” onto the “GF305” peach infected with Dideron-type (PPV-D isolates progressively reduces disease symptoms and virus accumulation. Furthermore, grafting “Garrigues” onto “GF305” prior to PPV-D inoculation has been found to completely prevent virus infection, showing that resistance is constitutive and not induced by the virus. To unravel the phytohormone signaling of this mechanism, we analyzed the following phytohormones belonging to the principal hormone classes: the growth-related phytohormones cytokinin trans-zeatin (tZ and the gibberellins GA3 and GA4; and the stress-related phytohormones ethylene acid precursor 1-aminocyclopropane-1-carboxylic acid (ACC, abscisic acid (ABA, salicylic acid (SA, and jasmonic acid (JA. PPV inoculation produced a significant increase in GA3 and ABA in peach, and these imbalances were related to the presence of chlorosis symptoms. However, grafting “Garrigues” almond onto the PPV-inoculated “GF305” peach produced the opposite effect, reducing GA3 and ABA contents in parallel to the elimination of symptoms. Our results showed the significant implication of SA in this induced resistance in peach with an additional effect on tZ and JA concentrations. This SA-induced resistance based in the decrease in symptoms seems to be different from Systemic Acquired Resistance (SAR and Induced Systemic Resistance (ISR, which are based in other reactions producing necrosis. Further studies are necessary, however, to validate these results against PPV-D isolates in the more aggressive Marcus-type (PPV-M isolates.

  17. The diagnostic accuracy of physical examination compared to lung ultrasound for determining lung congestion in hemodialysis patients who have reached their dry weight

    Science.gov (United States)

    Rahardjo, K. D.; Dharmaeizar; Nainggolan, G.; Harimurti, K.

    2017-08-01

    Research has shown that hemodialysis patients with lung congestion have high morbidity and mortality. Patients were assumed to be free of lung congestion if they had reached their post-dialysis dry weight. Most often, to determine if the patient was free of lung congestion, physical examination was used. However, the accuracy of physical examination in detecting lung congestion has not been established. To compare the capabilities of physical examination and lung ultrasound in detection of lung congestion, cross-sectional data collection was conducted on hemodialysis patients. Analysis was done to obtain proportion, sensitivity, specificity, positive predictive value, negative predictive value, and positive likelihood ratio. Sixty patients participated in this study. The inter observer variation of 20 patients revealed a kappa value of 0.828. When all 60 patients were taken into account, we found that 36 patients (57.1%) had lung congestion. Mild lung congestion was found in 24 (38.1%), and 12 (19%) had a moderate degree of congestion. In the analysis comparing jugular venous pressure to lung ultrasound, we found that sensitivity was 0.47 (0.31-0.63), specificity was 0.73 (0.54-0.86), positive predictive value (PPV) was 0.51 (0.36-0.67), negative predictive value (NPV) was 0.70 (0.49-0.84), positive likelihood ratio (PLR) was 1.75 (0.88-3.47), and the negative likelihood ratio (NLR) was 0.72 (0.47-1.12). In terms of lung auscultation, we found that sensitivity was 0.56 (0.39-0.71), specificity was 0.54 (0.35-0.71), PPV was 0.61 (0.44-0.76), NPV was 0.48 (0.31-0.66), PLR was 1.21 (0.73-2.0), and NLR was 0.82 (0.49-1.38). The results of our study showed that jugular venous distention and lung auscultation examination are not reliable means of detecting lung congestion.

  18. Workgroup Report by the Joint Task Force Involving American Academy of Allergy, Asthma & Immunology (AAAAI); Food Allergy, Anaphylaxis, Dermatology and Drug Allergy (FADDA) (Adverse Reactions to Foods Committee and Adverse Reactions to Drugs, Biologicals, and Latex Committee); and the Centers for Disease Control and Prevention Botulism Clinical Treatment Guidelines Workgroup-Allergic Reactions to Botulinum Antitoxin: A Systematic Review.

    Science.gov (United States)

    Schussler, Edith; Sobel, Jeremy; Hsu, Joy; Yu, Patricia; Meaney-Delman, Dana; Grammer, Leslie C; Nowak-Wegrzyn, Anna

    2017-12-27

    Naturally occurring botulism is rare, but a large number of cases could result from unintentional or intentional contamination of a commercial food. Despeciated, equine-derived, heptavalent botulinum antitoxin (HBAT) is licensed in the United States. Timely treatment reduces morbidity and mortality, but concerns that botulinum antitoxin can induce anaphylaxis exist. We sought to quantify the allergy risk of botulinum antitoxin treatment and the usefulness of skin testing to assess this risk. We conducted a systematic review of (1) allergic reactions to botulinum antitoxin and (2) the predictive value of skin testing (ST) before botulinum antitoxin administration. We searched 5 scientific literature databases, reviewed articles' references, and obtained data from the HBAT manufacturer and from the Centers for Disease Control and Prevention. Anaphylaxis incidence was determined for HBAT and previously employed botulinum antitoxins. We calculated the positive predictive value (PPV) and negative predictive value (NPV) of ST for anaphylaxis related to HBAT and other botulinum antitoxins. Seven articles were included. Anaphylaxis incidence was 1.64% (5/305 patients) for HBAT and 1.16% (8/687 patients) for all other botulinum antitoxins (relative risk, 1.41 [95% confidence interval, .47-4.27]; P = .5). Observed values for both PPV and NPV for HBAT-ST (33 patients) were 100%. Observed PPVs and NPVs of ST for other botulinum antitoxins (302 patients) were 0-56% and 50%-100%, respectively. There were no reports of fatal anaphylaxis. Considering the <2 % rate of anaphylaxis, fatal outcomes, modest predictive value of ST, resource requirements for ST, and the benefits of early treatment, data do not support delaying HBAT administration to perform ST in a mass botulinum toxin exposure. Anaphylactic reactions may occur among 1%-2% of botulinum antitoxin recipients and will require epinephrine and antihistamine treatment and, possibly, intensive care. Published by Oxford

  19. Proton magnetic resonance spectroscopy in the distinction of high-grade cerebral gliomas from single metastatic brain tumors

    International Nuclear Information System (INIS)

    Server, Andres; Schellhorn, Till; Haakonsen, Monika; Nakstad, Per H.; Josefsen, Roger; Kulle, Bettina; Maehlen, Jan; Kumar, Theresa; Gadmar, Oeystein; Langberg, Carl W.

    2010-01-01

    Background: Brain metastases and primary high-grade gliomas, including glioblastomas multiforme (GBM) and anaplastic astrocytomas (AA), may be indistinguishable by conventional magnetic resonance (MR) imaging. Identification of these tumors may have therapeutic consequences. Purpose: To assess the value of MR spectroscopy (MRS) using short and intermediate echo time (TE) in differentiating solitary brain metastases and high-grade gliomas on the basis of differences in metabolite ratios in the intratumoral and peritumoral region. Material and Methods: We performed MR imaging and MRS in 73 patients with histologically verified intraaxial brain tumors: 53 patients with high-grade gliomas (34 GBM and 19 AA) and 20 patients with metastatic brain tumors. The metabolite ratios of Cho/Cr, Cho/NAA, and NAA/Cr at intermediate TE and the presence of lipids at short TE were assessed from spectral maps in the tumoral core, peritumoral edema, and contralateral normal-appearing white matter. The differences in the metabolite ratios between high-grade gliomas/GBM/AA and metastases were analyzed statistically. Cutoff values of Cho/Cr, Cho/NAA, and NAA/Cr ratios in the peritumoral edema, as well as Cho/Cr and NAA/Cr ratios in the tumoral core for distinguishing high-grade gliomas/GBM/AA from metastases were determined by receiver operating characteristic (ROC) curve analysis. Results: Significant differences were noted in the peritumoral Cho/Cr, Cho/NAA, and NAA/ Cr ratios between high-grade gliomas/GBM/AA and metastases. ROC analysis demonstrated a cutoff value of 1.24 for peritumoral Cho/Cr ratio to provide sensitivity, specificity, positive (PPV), and negative predictive values (NPV) of 100%, 88.9%, 80.0%, and 100%, respectively, for discrimination between high-grade gliomas and metastases. By using a cutoff value of 1.11 for peritumoral Cho/NAA ratio, the sensitivity was 100%, the specificity was 91.1%, the PPV was 83.3%, and the NPV was 100%. Conclusion: The results of this

  20. Comparison of four urease-dependent tests of detecting HP infection

    International Nuclear Information System (INIS)

    Han Yuan; Huang Gang; Zhu Cuiying; Ling Liqun

    2001-01-01

    Objective: The aim of this study is to compare the four urease-dependent tests of detecting Hp infection. The authors used following method: 1) rapid urease test (RUT), 2) 14 C urea breath test ( 14 C-UBT), 3) 13 C urea breath test which is measured by with infrared spectrometry ( 13 C-UBT1), 4) 13 C urea breath test with mass spectrometry ( 13 C-UBT). Methods: 54 patients underwent RUT, 14 C-UBT, 13 C-UBT1, 13 C-UBT2 respectively. Results: Sensitivity and specificity, accurate rate, positive predictive value (PPV), negative predictive value (NPV), respectively, were as follows: RUT (82.1%, 80%, 81.5%, 91.4%, 63.2%), 14 C-UBT (97.4%, 100%, 98.1%, 100%, 93.8%), 13 C-UBT1 (100%, 93.3%, 98.1%, 97.5%, 100%), 13 C-UBT2 (100%, 86.7%, 96.3%, 95.1%, 100%), PPV of four tests are not significantly different (P>0.05). Conclusion: Four urease-dependent tests are high sensitive and accurate methods for detecting Hp infection. UBT is an ideal tool for diagnosis, screen and follow-up of Hp infection