WorldWideScience

Sample records for values ppv negative

  1. Thermoluminescence and photoluminescence analyses of MEH-PPV, MDMO-PPV and RU(bpy)3 gamma-irradiated polymer thin films

    International Nuclear Information System (INIS)

    Ortiz-Morales, A.; Ortiz-Lopez, J.; Cruz-Zaragoza, E.; Gómez-Aguilar, R.

    2015-01-01

    Effects of irradiation with 60 Co gamma photons on poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV), poly[2-methoxy-5-(3′,7′ dimethyloctyloxy)-1,4-phenylenevinylene] (MDMO-PPV) and tris(2,2′-bipyridyl)dichlororuthenium(II) hexahydrate (Ru(bpy) 3 ) thin films were analyzed regarding their thermoluminescence (TL) and photoluminescence (PL) properties. A linear TL dose response was obtained from the MEH-PPV and MDMO-PPV polymer films in dose ranges of approximately 0.170–4.08 kGy and 0.170–0.850 kGy, respectively, followed by a supralinear behavior. A dependence on the conjugation length of the polymer chains which was favored by heating of the film, was observed, and irradiation generated a blue-shift in MEH-PPV and Ru(bpy) 3 . Furthermore, the PL structure was not modified. The most likely effect involved in the TL emission was trapping. The high activation energy values of the traps in the TL may be attributed in part to the binding energy of the exciton. A deconvolution process was carried out to obtain the kinetic parameters from the TL glow curves and PL spectra. - Highlights: • Irradiation effects on MEH-PPV, MDMO-PPV and Ru(bpy) 3 were analyzed by TL and PL. • The dose response of PPV derivatives was linear at higher doses (0.170–4.08 kGy). • Activation energy, was larger than 2 eV, suggest a possible good stability of traps. • PL spectra for non-irradiated and gamma irradiated polymer are almost identical

  2. Addendum to the article: Misuse of null hypothesis significance testing: Would estimation of positive and negative predictive values improve certainty of chemical risk assessment?

    Science.gov (United States)

    Bundschuh, Mirco; Newman, Michael C; Zubrod, Jochen P; Seitz, Frank; Rosenfeldt, Ricki R; Schulz, Ralf

    2015-03-01

    We argued recently that the positive predictive value (PPV) and the negative predictive value (NPV) are valuable metrics to include during null hypothesis significance testing: They inform the researcher about the probability of statistically significant and non-significant test outcomes actually being true. Although commonly misunderstood, a reported p value estimates only the probability of obtaining the results or more extreme results if the null hypothesis of no effect was true. Calculations of the more informative PPV and NPV require a priori estimate of the probability (R). The present document discusses challenges of estimating R.

  3. Modeling charge transport properties of cyano-substituted PPV

    International Nuclear Information System (INIS)

    Correia, Helena M.G.; Ramos, Marta M.D.

    2003-01-01

    In recent years, poly (p-phenylenevinylene) (PPV) and its derivatives have attracted much interest due to their applications in light-emitting diodes (LEDs). One of the issues that determine device performance is the transport of charge carriers along the polymer strands. For that reason, we investigate the influence of cyano substitution on geometry and electronic behaviour of PPV chains using self-consistent quantum molecular dynamics simulations. Our results suggest that substitution by cyano groups induce distortion in the PPV chains and a charge rearrangement among the polymer atoms. Specifically addressed is the issue concerning estimates of charge (electron and hole) mobility by computer experiments. Significant differences have been found both in the strength of the electric field needed to move positive and negative charge carriers along the polymer chain as well as in charge mobility

  4. Langmuir-Blodgett film based on MEH-PPV for cholesterol biosensor

    International Nuclear Information System (INIS)

    Matharu, Zimple; Arya, Sunil K.; Singh, S.P.; Gupta, Vinay; Malhotra, B.D.

    2009-01-01

    Cholesterol oxidase (ChOx) has been immobilized onto conducting poly[2-methoxy,5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV)/stearic acid (SA) Langmuir-Blodgett film transferred onto octadecanethiol (ODT) modified gold plate. The ChOx/MEH-PPV/SA LB film bioelectrode exhibits has been characterized by FT-IR, contact angle, and atomic force microscopy. The response of the ChOx/MEH-PPV/SA LB film bioelectrode carried out using differential pulse voltammetry (DPV) studies reveal linearity from 1.29 to 12.91 mM of cholesterol concentration and response time as 30 s. This ChOx/MEH-PPV/SA bioelectrode exhibits values of correlation coefficient as 0.9939, standard deviation as 0.0029 μA and limit of detection as 1.66 mM. UV-visible spectrophotometer studies reveal that 5.2 x 10 -3 U of ChOx are actively working per cm 2 area of ChOx/MEH-PPV/SA LB film bioelectrode and this bioelectrode is thermally stable upto 55 deg. C with reusability of about 60 times

  5. Langmuir-Blodgett film based on MEH-PPV for cholesterol biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Matharu, Zimple [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Arya, Sunil K.; Singh, S.P. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Gupta, Vinay [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Malhotra, B.D. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India)], E-mail: bansi.malhotra@gmail.com

    2009-02-23

    Cholesterol oxidase (ChOx) has been immobilized onto conducting poly[2-methoxy,5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV)/stearic acid (SA) Langmuir-Blodgett film transferred onto octadecanethiol (ODT) modified gold plate. The ChOx/MEH-PPV/SA LB film bioelectrode exhibits has been characterized by FT-IR, contact angle, and atomic force microscopy. The response of the ChOx/MEH-PPV/SA LB film bioelectrode carried out using differential pulse voltammetry (DPV) studies reveal linearity from 1.29 to 12.91 mM of cholesterol concentration and response time as 30 s. This ChOx/MEH-PPV/SA bioelectrode exhibits values of correlation coefficient as 0.9939, standard deviation as 0.0029 {mu}A and limit of detection as 1.66 mM. UV-visible spectrophotometer studies reveal that 5.2 x 10{sup -3} U of ChOx are actively working per cm{sup 2} area of ChOx/MEH-PPV/SA LB film bioelectrode and this bioelectrode is thermally stable upto 55 deg. C with reusability of about 60 times.

  6. Genome sequence of Chinese porcine parvovirus strain PPV2010.

    Science.gov (United States)

    Cui, Jin; Wang, Xin; Ren, Yudong; Cui, Shangjin; Li, Guangxing; Ren, Xiaofeng

    2012-02-01

    Porcine parvovirus (PPV) isolate PPV2010 has recently emerged in China. Herein, we analyze the complete genome sequence of PPV2010. Our results indicate that the genome of PPV2010 bears mixed characteristics of virulent PPV and vaccine strains. Importantly, PPV2010 has the potential to be a naturally attenuated candidate vaccine strain.

  7. Genome Sequence of Chinese Porcine Parvovirus Strain PPV2010

    OpenAIRE

    Cui, Jin; Wang, Xin; Ren, Yudong; Cui, Shangjin; Li, Guangxing; Ren, Xiaofeng

    2012-01-01

    Porcine parvovirus (PPV) isolate PPV2010 has recently emerged in China. Herein, we analyze the complete genome sequence of PPV2010. Our results indicate that the genome of PPV2010 bears mixed characteristics of virulent PPV and vaccine strains. Importantly, PPV2010 has the potential to be a naturally attenuated candidate vaccine strain.

  8. A Multicenter Retrospective Review of Prone Position Ventilation (PPV in Treatment of Severe Human H7N9 Avian Flu.

    Directory of Open Access Journals (Sweden)

    Yuanda Xu

    Full Text Available Patients with H7N9 avian flu concurrent with severe acute respiratory distress syndrome (ARDS usually have a poor clinical outcome. Prone position ventilation (PPV has been shown to improve the prognosis of patients with severe ARDS. This study explored the effects of PPV on the respiratory and circulatory mechanics of H7N9-infected patients with severe ARDS.Individuals admitted to four hospitals designated for H7N9 patients in Guangdong province were treated with PPV, and their clinical data were recorded before and after receiving PPV.Six of 20 critically ill patients in the ICU received PPV. After treatment with 35 PPV sessions, the oxygenation index (OI values of the six patients when measured post-PPV and post-supine position ventilation (SPV were significantly higher than those measured pre-PPV (P < 0.05.The six patients showed no significant differences in their values for respiratory rate (RR, peak inspiratory pressure (PIP, tidal volume (TV or arterial partial pressure of carbon dioxide (PaCO2 when compared pre-PPV, post-PPV, and post-SPV. Additionally, there were no significant differences in the mean values for arterial pressure (MAP, cardiac index (CI, central venous pressure (CVP, heart rate (HR, lactic acid (LAC levels or the doses of norepinephrine (NE administered when compared pre-PPV, post-PPV, and post-SPV.PPV provided improved oxygenation that was sustained after returning to a supine position, and resulted in decreased carbon dioxide retention. PPV can thus serve as an alternative lung protective ventilation strategy for use in patients with H7N9 avian flu concurrent with severe ARDS.

  9. Measurement of kVp, PPV and air kerma values in function of the electric current quantity and the focus-detector distance in one X-ray equipment

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F. de; Potiens, Maria da Penha A.; Vivolo, Vitor

    2009-01-01

    The objective of this work was to study the behavior of the X-ray equipment Pantak/Seifert, model MXR-160/22 of the calibration laboratory of IPEN, LCI, operating in the diagnostic radiology radiation quality RQR 5 (70 kV). For this evaluation it was used a noninvasive meter PTW, Diavolt TM model. The measurements of kVp, PPV and Dose (air kerma), were made varying the electric current and distance between the focal point and the meter. This behavior is described in the literature and was expected in the analysis of the measurements for comparison purposes. For the tests where it was only increased the electric current it was waited a linear increase of the dose (air kerma), but not a variation in the kVp and PPV. The measurements had corresponded to the waited behavior, since the Dose (air kerma) measurements presented a linear increase with the increase of the electric current and the kVp and PPV values showed a variation less than 2%. In the corresponding measurements increasing the distance between focal point and meter, it was waited the exponentially decreasing of the Dose (air kerma) and again a small variation or no variation of the PPV and kVP with the increase of the distance. Over again the measurements corresponded to the expected, where the Dose (air kerma) decreased exponentially and the PPV and the kVp had a variation less than 1.5%. (author)

  10. Enhancement in fluorescence quantum yield of MEH-PPV:BT blends for polymer light emitting diode applications

    Science.gov (United States)

    Nimith, K. M.; Satyanarayan, M. N.; Umesh, G.

    2018-06-01

    We have investigated the effect of blending electron deficient heterocycle Benzothiadiazole (BT) on the photo-physical properties of conjugated polymer Poly [2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV). Quantum yield (QY) value has been found to increase from 37% for pure MEH-PPV to 45% for an optimum MEH-PPV:BT blend ratio of 1:3. This can be attributed to the efficient energy transfer from the wide bandgap BT (host) to the small bandgap MEH-PPV (guest). The FTIR spectrum of MEH-PPV:BT blended thin film indicates suppression of aromatic C-H out-of-plane and in-plane bending, suggesting planarization of the conjugated polymer chains and, hence, leading to increase in the conjugation length. The increase in conjugation length is also evident from the red-shifted PL spectra of MEH-PPV:BT blended films. Single layer MEH-PPV:BT device shows lower turn-on voltage than single layer MEH-PPV alone device. Further, the effect of electrical conductivity of PEDOT:PSS on the current-voltage characteristics is investigated in the PLED devices with MEH-PPV:BT blend as the active layer. PEDOT:PSS with higher conductivity as HIL reduces the turn on voltage from 4.5 V to 3.9 V and enhances the current density and optical output in the device.

  11. Solar Cell Polymer Based Active Ingredients PPV and PCBM

    Science.gov (United States)

    Hardeli, H.; Sanjaya, H.; Resikarnila, R.; Nitami H, R.

    2018-04-01

    A polymer solar cell is a solar cell based on a polymer bulk heterojunction structure using the method of thin film, which can convert solar energy into electrical energy. Absorption of light is carried by active material layer PPV: PCBM. This study aims to make solar cells tandem and know the value of converting solar energy into electrical energy and increase the value of efficiency generated through morphological control, ie annealing temperature and the ratio of active layer mixture. The active layer is positioned above the PEDOT:PSS layer on ITO glass substrate. The characterization results show the surface morphology of the PPV:PCBM active layer is quite evenly at annealing temperature of 165 ° C. The result of conversion of electrical energy with a UV light source in annealing samples with temperature 165 ° C is 0.03 mA and voltage of 4.085 V with an efficiency of 2.61% and mixed ratio variation was obtained in comparison of P3HT: PCBM is 1: 3

  12. A Multicenter Retrospective Review of Prone Position Ventilation (PPV) in Treatment of Severe Human H7N9 Avian Flu.

    Science.gov (United States)

    Xu, Yuanda; Deng, Xilong; Han, Yun; Zhou, Lixin; He, Weiqun; Chen, Sibei; Nong, Lingbo; Huang, Huang; Zhang, Yan; Yu, Tieou; Li, Yimin; Liu, Xiaoqing

    2015-01-01

    Patients with H7N9 avian flu concurrent with severe acute respiratory distress syndrome (ARDS) usually have a poor clinical outcome. Prone position ventilation (PPV) has been shown to improve the prognosis of patients with severe ARDS. This study explored the effects of PPV on the respiratory and circulatory mechanics of H7N9-infected patients with severe ARDS. Individuals admitted to four hospitals designated for H7N9 patients in Guangdong province were treated with PPV, and their clinical data were recorded before and after receiving PPV. Six of 20 critically ill patients in the ICU received PPV. After treatment with 35 PPV sessions, the oxygenation index (OI) values of the six patients when measured post-PPV and post-supine position ventilation (SPV) were significantly higher than those measured pre-PPV (P protective ventilation strategy for use in patients with H7N9 avian flu concurrent with severe ARDS.

  13. Danske PPV-stammer har ændret sig genetisk

    DEFF Research Database (Denmark)

    Hjulsager, Charlotte Kristiane; Krog, Jesper Schak; Larsen, Lars Erik

    2015-01-01

    I 2015 er der set en markant stigning i antallet af positive fund af porcin parvovirus (PPV) i indsendelser til undersogelse af svineaborter (Tabel 1). PPV forekommer udbredt i svinebesætninger og kan forårsage reproduktionsproblemer. Disse kan imidlertid kontrolleres med vacciner, der dog ikke...... forhindrer infektion og virusudskillelse fra soerne, men beskytter mod reproduktionsproblemerne. PPV-viruspartiklerne er meget modstandsdygtige overfor nedbrydelse i omgivelserne, så da virus formodentlig findes i de fleste besatninger, er det vigtigt med effektiv vaccination af alle avlsdyr for at beskytte...

  14. Effect of Pedot-Pss on Electrical and Photovoltaic Properties of ITO/MEH-PPV:PCBM/Al Organic Diodes

    International Nuclear Information System (INIS)

    Gunduz, B.

    2008-01-01

    The photovoltaic and electrical properties of ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al organic diodes have been investigated. The ideality factor, series resistance and shunt resistance values of ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al diodes were found to be 4.6, 6.84x10 6 Ω, 2.2x10 8 Ω and 4.02, 5.8x10 5 Ω, 2x10 7 Ω respectively. The electronic parameters of the ITO/MEH-PPV:PCBM/Al diode were improved using PEDOT-PSS conducting polymer. ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al organic diodes indicate a photovoltaic behaviour with a maximum open circuit voltage V o c and short-circuit current I s c. The photoconductivity sensitivity and responsivity properties of the organic diodes have been characterized by transient-current measurements. The obtained electrical and photovoltaic results indicate that ITO/MEH-PPV:PCBM/Al and ITO/PEDOT-PSS/MEHPPV:PCBM/Al structures are the organic photodiodes with calculated electronic parameters and the electrical properties of the ITO/MEH-PPV:PCBM/Al diode have been improved with PEDOT-PSS conducting polymer

  15. Effect of solution concentration on MEH-PPV thin films

    Science.gov (United States)

    Affendi, I. H. H.; Sarah, M. S. P.; Alrokayan, Salman A. H.; Khan, Haseeb A.; Rusop, M.

    2018-05-01

    MEH-PPV thin films were prepared with a mixture of THF (tetrahydrofuran) solution deposited by spin coating method. The surface topology of MEH-PPV thin film were characterize by atomic force microscopy (AFM) and optical properties of absorption spectra were characterized by using Ultraviolet-visible-near-infrared (UV-Vis-NIR). The MEH-PPV concentration variation affects the surface and optical properties of the thin film where 0.5 mg/ml MEH-PPV concentration have a good surface topology provided the same film also gives the highest absorption coefficient were then deposited to a TiO2 thin film forming composite layer. The composite layer then shows low current flow of short circuit current of Isc = -5.313E-7 A.

  16. Optically active vibrational modes of PPV derivatives on textile substrate

    International Nuclear Information System (INIS)

    Silva, M.A.T. da; Dias, I.F.L.; Santos, E.P. dos; Martins, A.A.; Duarte, J.L.; Laureto, E.; Reis, G.A. dos; Guimarães, P.S.S.; Cury, L.A.

    2013-01-01

    In this work, MEH-PPV and BDMO-PPV films were deposited by spin-coating on “dirty” textile substrates of canvas, nylon, canvas with resin, jeans and on glass and the temperature dependence of the optical properties of them was studied by photoluminescence and Raman (300 K) techniques. The temperature dependence of the energy, of the half line width at half height of the purely electronic peak, of the integrated PL intensity and of the Huang-Rhys factor, S=I (01) /I (00) , were obtained directly from the PL spectrum. For an analysis of the vibrational modes involved, Raman measurements were performed on substrates with and without polymers deposited and the results compared with those found in the literature. The films of MEH-PPV and BDMO-PPV showed optical properties similar to those films deposited on other substrates such as glass, metals, etc. It was observed an inversion of the first vibrational band in relation to the purely electronic peak with increasing temperature in the films deposited on nylon and canvas. The vibrational modes obtained by Raman were used to compose the simulation of the PL line shape of BDMO-PPV films on canvas and nylon, using a model proposed by Lin [29]. - Highlights: ► MEH-PPV and BDMO-PPV films were deposited by spin-coating on dirty textile. ► Their properties were studied by photoluminescence and Raman techniques. ► We observed inversion of first vibrational band in relation to purely electronic peak. ► Optically active vibrational modes of PPV derivatives were studied.

  17. The value of precontrast thoraco-abdominopelvic CT in polytrauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Esposito, A.A., E-mail: rxandreaesposito@yahoo.it [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy); Zilocchi, M., E-mail: massimo.zilocchi@gmail.com [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy); Fasani, P., E-mail: fasapier65@gmail.com [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy); Giannitto, C., E-mail: caterina.giannitto@gmail.com [School of Radiology, University of Milan, Via A. di Rudinì 8, Milan (Italy); Maccagnoni, S., E-mail: maccagnnisara@libero.it [School of Radiology, University of Milan, Via A. di Rudinì 8, Milan (Italy); Maniglio, M., E-mail: marinamaniglio@gmail.com [School of Radiology, University of Milan, Via A. di Rudinì 8, Milan (Italy); Campoleoni, M., E-mail: campoleoni@policlinico.mi.it [Medical Phisic Unit, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20121 Milan (Italy); Brambilla, R., E-mail: roberto.brambilla@policlinico.mi.it [Medical Phisic Unit, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20121 Milan (Italy); Casiraghi, E., E-mail: casiraghi@di.unimi.it [Computer Science Department, University of Milan, Via Comelico 39, Milan (Italy); Biondetti, P.R., E-mail: pibionde@tin.it [Department of Radiology, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20121 Milan (Italy)

    2015-06-15

    Highlights: • We evaluated the additional value of precontrast CT in polytrauma patient. • We evaluated the radiation dose CT in polytrauma patient. • Precontrast CT scan does not have an additional value in polytrauma patient. • Precontrast CT expose patient to an unjustified radiation dose. - Abstract: Purpose: To evaluate the utility and radiation dose of thoraco-abdominopelvic precontrast CT in polytrauma patients. Materials and methods: We examined retrospectively 125 patients who underwent a thoraco-abdominopelvic CT for trauma. Two radiologists, independently, evaluated precontrast CT acquisition and two other radiologists examined the contrast-enhanced scans. A further two radiologists assessed both the acquisitions. Mean value of sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) were calculated by each group of radiologists. For 104 patients, CTDIvol, DLP data and individual mean size were collected to calculate effective dose. Results: Mean values of SE, SP, PPV and NPV of findings of radiologists who assessed contrast-enhanced acquisitions were respectively: SE = 85%, SP = 98%, PPV = 86%, NPV = 88% versus: SE = 43%, SP = 95%, PPV = 69%, NPV = 88% of radiologists who examined non-contrast-enhanced scans. Mean values of radiologists who analyzed both acquisitions were: SE = 80%, SP = 97%, PPV = 80%, NPV = 88%. Neither the precontrast scans nor the precontrast and postcontrast scans together provided additional useful information compared to the single contrast-enhanced acquisition. Patients received a mean dose of 12 mSv for the precontrast CT. Conclusions: Precontrast CT acquisition did not provide significant information in trauma patients, exposing them to an unjustified radiation dose.

  18. The value of precontrast thoraco-abdominopelvic CT in polytrauma patients

    International Nuclear Information System (INIS)

    Esposito, A.A.; Zilocchi, M.; Fasani, P.; Giannitto, C.; Maccagnoni, S.; Maniglio, M.; Campoleoni, M.; Brambilla, R.; Casiraghi, E.; Biondetti, P.R.

    2015-01-01

    Highlights: • We evaluated the additional value of precontrast CT in polytrauma patient. • We evaluated the radiation dose CT in polytrauma patient. • Precontrast CT scan does not have an additional value in polytrauma patient. • Precontrast CT expose patient to an unjustified radiation dose. - Abstract: Purpose: To evaluate the utility and radiation dose of thoraco-abdominopelvic precontrast CT in polytrauma patients. Materials and methods: We examined retrospectively 125 patients who underwent a thoraco-abdominopelvic CT for trauma. Two radiologists, independently, evaluated precontrast CT acquisition and two other radiologists examined the contrast-enhanced scans. A further two radiologists assessed both the acquisitions. Mean value of sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) were calculated by each group of radiologists. For 104 patients, CTDIvol, DLP data and individual mean size were collected to calculate effective dose. Results: Mean values of SE, SP, PPV and NPV of findings of radiologists who assessed contrast-enhanced acquisitions were respectively: SE = 85%, SP = 98%, PPV = 86%, NPV = 88% versus: SE = 43%, SP = 95%, PPV = 69%, NPV = 88% of radiologists who examined non-contrast-enhanced scans. Mean values of radiologists who analyzed both acquisitions were: SE = 80%, SP = 97%, PPV = 80%, NPV = 88%. Neither the precontrast scans nor the precontrast and postcontrast scans together provided additional useful information compared to the single contrast-enhanced acquisition. Patients received a mean dose of 12 mSv for the precontrast CT. Conclusions: Precontrast CT acquisition did not provide significant information in trauma patients, exposing them to an unjustified radiation dose

  19. Plum pox virus (PPV) genome expression in genetically engineered RNAi plants

    Science.gov (United States)

    An important approach to controlling sharka disease caused by Plum pox virus (PPV) is the development of PPV resistant plants using small interfering RNAs (siRNA) technology. In order to evaluate siRNA induced gene silencing, we studied, based on knowledge of the PPV genome sequence, virus genome t...

  20. Surface-Enhanced Raman Scattering of MEH-PPV on Gold and Silver Nanoparticles

    Directory of Open Access Journals (Sweden)

    Beatriz R. Moraes

    2018-01-01

    Full Text Available The interaction of poly[2-methoxy-5-(2-ethylhexyloxy-1,4-phenylenevinylene] (MEH-PPV with Au or Ag nanospheres, Au nanostars, and Ag nanoprisms was investigated using surface-enhanced Raman scattering (SERS. The SERS investigation showed that adsorption of MEH-PPV strongly depends on the nature of the nanoparticle surface. On gold nanostars that present a thick layer of capping polymer, SERS spectrum is only observed in relatively concentrated MEH-PPV solution (1 mmol L−1. On the other hand, Au and Ag nanospheres present SERS spectra down to 10−6 mol L−1 and no chemical interaction of MEH-PPV and metal surface is observed. The spectra of MEH-PPV on Ag nanoprisms with PVP as stabilizing agent suggest that the capping polymer induces a planar conformation of MEH-PPV and consequently an increase of conjugation length. These results give support for the application of MEH-PPV on optoelectronics in which interfacial effects are critical in the device efficiency and stability.

  1. Enhancement of the solubility, thermal stability, and electronic properties of carbon nanotubes functionalized with MEH-PPV: A combined experimental and computational study

    International Nuclear Information System (INIS)

    Prajongtat, P.; Suramitr, S.; Hannongbua, S.; Gleeson, M.P.; Mitsuke, K.

    2013-01-01

    Multi-walled carbon nanotubes (MWCNTs) functionalized with poly[2-methoxy-5-(2′-ethylhexyloxy)-1,4-phenylenevinylene] (MWCNT-f-MEH-PPV) nanocomposites were successfully prepared by employing a “grafting from” approach. The content of the functionalizing MEH-PPV in the composites was observed as 76 wt.%. Compared with pristine MWCNTs (p-MWCNT), the aqueous solubility and thermal stability of the former are significantly enhanced. The effect of covalently and non-covalently functionalized nanotubes on dye-sensitized solar cell performance was also studied. Solar cells were successfully fabricated from isolated MEH-PPV, p-MWCNT/MEH-PPV, and MWCNT-f-MEH-PPV/MEH-PPV counter electrodes. The devices based on a MWCNT-f-MEH-PPV/MEH-PPV counter electrode demonstrated the best photovoltaic performance as observed by higher J SC, V OC, and fill factor (FF) values. The experimental phenomena can be explained by quantum-chemical calculations: Charge transfer from MEH-PPV oligomers to nanotubes is greater when covalently functionalized compared with non-covalently functionalized. This suggests that the improvement in the photovoltaic parameters of the cells containing covalently functionalized nanotubes results not only from the higher concentration present in the nanotube films of the counter electrode, but also from the greater electron delocalization between the oligomers and nanotubes. (author)

  2. Determination of the diagnostic x-ray tube practical peak voltage (PPV) from average or average peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hourdakis, C J, E-mail: khour@gaec.gr [Ionizing Radiation Calibration Laboratory-Greek Atomic Energy Commission, PO Box 60092, 15310 Agia Paraskevi, Athens, Attiki (Greece)

    2011-04-07

    The practical peak voltage (PPV) has been adopted as the reference measuring quantity for the x-ray tube voltage. However, the majority of commercial kV-meter models measure the average peak, U-bar{sub P}, the average, U-bar, the effective, U{sub eff} or the maximum peak, U{sub P} tube voltage. This work proposed a method for determination of the PPV from measurements with a kV-meter that measures the average U-bar or the average peak, U-bar{sub p} voltage. The kV-meter reading can be converted to the PPV by applying appropriate calibration coefficients and conversion factors. The average peak k{sub PPV,kVp} and the average k{sub PPV,Uav} conversion factors were calculated from virtual voltage waveforms for conventional diagnostic radiology (50-150 kV) and mammography (22-35 kV) tube voltages and for voltage ripples from 0% to 100%. Regression equation and coefficients provide the appropriate conversion factors at any given tube voltage and ripple. The influence of voltage waveform irregularities, like 'spikes' and pulse amplitude variations, on the conversion factors was investigated and discussed. The proposed method and the conversion factors were tested using six commercial kV-meters at several x-ray units. The deviations between the reference and the calculated - according to the proposed method - PPV values were less than 2%. Practical aspects on the voltage ripple measurement were addressed and discussed. The proposed method provides a rigorous base to determine the PPV with kV-meters from U-bar{sub p} and U-bar measurement. Users can benefit, since all kV-meters, irrespective of their measuring quantity, can be used to determine the PPV, complying with the IEC standard requirements.

  3. Identification and genomic characterization of a novel porcine parvovirus (PPV6) in China.

    Science.gov (United States)

    Ni, Jianqiang; Qiao, Caixia; Han, Xue; Han, Tao; Kang, Wenhua; Zi, Zhanchao; Cao, Zhen; Zhai, Xinyan; Cai, Xuepeng

    2014-12-02

    Parvoviruses are classified into two subfamilies based on their host range: the Parvovirinae, which infect vertebrates, and the Densovirinae, which mainly infect insects and other arthropods. In recent years, a number of novel parvoviruses belonging to the subfamily Parvovirinae have been identified from various animal species and humans, including human parvovirus 4 (PARV4), porcine hokovirus, ovine partetravirus, porcine parvovirus 4 (PPV4), and porcine parvovirus 5 (PPV5). Using sequence-independent single primer amplification (SISPA), a novel parvovirus within the subfamily Parvovirinae that was distinct from any known parvoviruses was identified and five full-length genome sequences were determined and analyzed. A novel porcine parvovirus, provisionally named PPV6, was initially identified from aborted pig fetuses in China. Retrospective studies revealed the prevalence of PPV6 in aborted pig fetuses and piglets(50% and 75%, respectively) was apparently higher than that in finishing pigs and sows (15.6% and 3.8% respectively). Furthermore, the prevalence of PPV6 in finishing pig was similar in affected and unaffected farms (i.e. 16.7% vs. 13.6%-21.7%). This finding indicates that animal age, perhaps due to increased innate immune resistance, strongly influences the level of PPV6 viremia. Complete genome sequencing and multiple alignments have shown that the nearly full-length genome sequences were approximately 6,100 nucleotides in length and shared 20.5%-42.6% DNA sequence identity with other members of the Parvovirinae subfamily. Phylogenetic analysis showed that PPV6 was significantly distinct from other known parvoviruses and was most closely related to PPV4. Our findings and review of published parvovirus sequences suggested that a novel porcine parvovirus is currently circulating in China and might be classified into the novel genus Copiparvovirus within the subfamily Parvovirinae. However, the clinical manifestations of PPV6 are still unknown in that the

  4. SYNTHESIS AND CHARACTERIZATION OF NOVEL BIPOLAR PPV-BASED COPOLYMER CONTAINING TRIAZOLE AND CARBAZOLE UNITS

    Institute of Scientific and Technical Information of China (English)

    Ze Liu; Li-xiang Wang; Xia-bin Jing; Fo-song Wang

    2001-01-01

    Two new blue light-emitting PPV-based conjugated copolymers containing both an electron-withdrawing unit (triazole-TAZ) and electron-rich moieties (carbazole-CAR and bicarbazole-BCAR) were prepared by Wittig condensation polymerization between the triazole diphosphonium salt and the corresponding dialdehyde monomers. Their structures and properties were characterized by FT-IR, TGA, DSC, UV-Vis, PL spectroscopy and electrochemical measurements. The resulting copolymers are soluble in common organic solvents and thermally stable with a Ts of 147C for TAZ-CAR-PPV and of 157C for TAZ-BCAR-PPV. The maximum photoluminescence wavelengths of TAZ-CAR-PPV and TAZ-BCAR-PPV film appear at 460 nm and 480 nm, respectively. Cyclic voltammetry measurement demonstrates that TAZ-BCAR-PPV has good electrochemical reversibility, while TAZ-CAR-PPV exhibits the irreversible redox process. The triazole unit was found to be an effective π-conjugation interrupter and can play the rigid spacer role in determining the emission colour of the resulting copolymer.

  5. Facile Synthesis of Well-Defined MDMO-PPV Containing (TriBlock—Copolymers via Controlled Radical Polymerization and CuAAC Conjugation

    Directory of Open Access Journals (Sweden)

    Neomy Zaquen

    2015-02-01

    Full Text Available A systematic investigation into the chain transfer polymerization of the so-called radical precursor polymerization of poly(p-phenylene vinylene (PPV materials is presented. Polymerizations are characterized by systematic variation of chain transfer agent (CTA concentration and reaction temperature. For the chain transfer constant, a negative activation energy of −12.8 kJ·mol−1 was deduced. Good control over molecular weight is achieved for both the sulfinyl and the dithiocarbamate route (DTC. PPVs with molecular weights ranging from thousands to ten thousands g·mol−1 were obtained. To allow for a meaningful analysis of the CTA influence, Mark–Houwink–Kuhn–Sakurada (MHKS parameters were determined for conjugated MDMO-PPV ([2-methoxy-5-(3',7'-dimethyloctyloxy]-1,4-phenylenevinylene to α = 0.809 and k = 0.00002 mL·g−1. Further, high-endgroup fidelity of the CBr4-derived PPVs was proven via chain extension experiments. MDMO-PPV-Br was successfully used as macroinitiator in atom transfer radical polymerization (ATRP with acrylates and styrene. A more polar PPV counterpart was chain extended by an acrylate in single-electron transfer living radical polymerization (SET-LRP. In a last step, copper-catalyzed azide alkyne cycloaddition (CuAAC was used to synthesize block copolymer structures. Direct azidation followed by macromolecular conjugation showed only partial success, while the successive chain extension via ATRP followed by CuAAC afforded triblock copolymers of the poly(p-phenylene vinylene-block-poly(tert-butyl acrylate-block-poly(ethylene glycol (PPV-b-PtBuA-b-PEG.

  6. Efficacy of PPV23 in Preventing Pneumococcal Pneumonia in Adults at Increased Risk--A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Julia Schiffner-Rohe

    Full Text Available Pneumococcal community-acquired pneumonia (pCAP is the most frequent form of pneumonia. The elderly and adults with underlying diseases are at an increased risk of developing pCAP. The 23-valent pneumococcal polysaccharide vaccine (PPV23 was licensed over 30 years ago and is recommended as the standard intervention in many countries across the globe, although its efficacy continues to be debated. We performed a meta-analysis of randomized controlled trials (RCTs to investigate the effect of PPV23 for preventing pCAP in adults ≥60 years of age.An existing Cochrane Review was updated to Oct 2014 using a systematic literature search to select appropriate RCTs. DerSimonian and Laird random-effects meta-analyses were performed and odd ratios (OR with 95%-confidence intervals (CI and p-values were calculated for the descriptive analyses. Reasons for heterogeneity were explored by subgroup analyses.Meta-analysis of PPV23 efficacy included four studies. Three of them did not demonstrate efficacy for PPV23. The body of evidence indicated statistically significant heterogeneity (I2 = 78%, p = 0.004 that could be explained by subgroup analysis by "study setting". Further effect modifiers for pCAP were "continent of trial" (p<0.01, and "method of pneumococcal diagnostics" (p = 0.001. Subgroup analyses revealed that the only study showing efficacy for PPV23 was an outlier. Overall, the validity of the meta-analytic PPV23 efficacy assessment was confirmed by the meta-analysis of all-cause CAP including six studies.Inconsistencies in PPV23 treatment effects to prevent pCAP could solely be explained by one outlier study that was performed in nursing homes in Japan. The effect modifier "method of pneumococcal diagnostics" should be interpreted carefully, since methodological weaknesses are not restricted to one special method only, which would justify the exclusion of certain studies. Overall, we conclude from our meta-analysis that to date there is no proof

  7. 20 g PPV with indocyanine green-assisted ILM peeling versus 23 g PPV with brilliant blue G-assisted ILM peeling for epiretinal membrane.

    Science.gov (United States)

    Manousaridis, Kleanthis; Peter, Silvia; Mennel, Stefan

    2016-06-01

    To compare the anatomical and visual outcomes of 20 gauge (g) pars plana vitrectomy (PPV) with indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling and 23 g PPV with brilliant blue G (BBG)-assisted ILM peeling for idiopathic epiretinal membrane (ERM). 38 eyes of 38 patients with idiopathic ERM were included. They were divided in two groups: group 1 (18 eyes) underwent 20 g PPV with ICG-assisted ILM peeling and group 2 (20 eyes) 23 g PPV with BBG-assisted ILM peeling. Postoperative best-corrected visual acuity (BCVA) and central macular thickness (CMT) were compared. Average BCVA in group 1 improved significantly from 0.60 logarithm of the minimal angle of resolution (log MAR) at baseline to 0.3 log MAR postoperatively. Average BCVA in group 2 improved significantly from 0.60 log MAR at baseline to 0.3 log MAR postoperatively. Mean CMT reduced significantly from 473 to 375 μm in group 1 and from 486 to 396 μm in group 2. There were no significant differences in the BCVA and CMT between the groups. Both surgical methods appeared to be safe and provided similar anatomical and visual outcomes.

  8. Hybrid device based on GaN nanoneedles and MEH-PPV/PEDOT:PSS polymer

    International Nuclear Information System (INIS)

    Shin, Min Jeong; Gwon, Dong-Oh; Lee, Chan-Mi; Lee, Gang Seok; Jeon, In-Jun; Ahn, Hyung Soo; Yi, Sam Nyung; Ha, Dong Han

    2015-01-01

    Highlights: • A hybrid device was demonstrated by using MEH-PPV, PEDOT:PSS, and GaN nanoneedles. • I–V curve of the hybrid device showed its rectification behaviour, similar to a diode. • EL peak originated by the different potential barriers at MEH-PPV and GaN interface. - Abstract: A hybrid device that combines the properties of organic and inorganic semiconductors was fabricated and studied. It incorporated poly[2-methoxy-5-(2-ethylhexyloxy)- 1,4-phenylenevinylene] (MEH-PPV) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as organic polymers and GaN nanoneedles as an inorganic semiconductor. Layers of the two polymers were spin coated on to the GaN nanoneedles. The one peak in the electroluminescence spectrum originated from the MEH-PPV layer owing to the different potential barriers of electrons and holes at its interface with the GaN nanoneedles. However, the photoluminescence spectrum showed peaks due to both GaN nanoneedles and MEH-PPV. Such hybrid structures, suitably developed, might be able to improve the efficiency of optoelectronic devices

  9. Hybrid device based on GaN nanoneedles and MEH-PPV/PEDOT:PSS polymer

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Min Jeong; Gwon, Dong-Oh; Lee, Chan-Mi; Lee, Gang Seok [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Jeon, In-Jun [Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Ahn, Hyung Soo [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Yi, Sam Nyung, E-mail: snyi@kmou.ac.kr [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Ha, Dong Han [Division of Convergence Technology, Korea Research Institute of Standards and Science, Daejeon 305-340 (Korea, Republic of)

    2015-08-15

    Highlights: • A hybrid device was demonstrated by using MEH-PPV, PEDOT:PSS, and GaN nanoneedles. • I–V curve of the hybrid device showed its rectification behaviour, similar to a diode. • EL peak originated by the different potential barriers at MEH-PPV and GaN interface. - Abstract: A hybrid device that combines the properties of organic and inorganic semiconductors was fabricated and studied. It incorporated poly[2-methoxy-5-(2-ethylhexyloxy)- 1,4-phenylenevinylene] (MEH-PPV) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as organic polymers and GaN nanoneedles as an inorganic semiconductor. Layers of the two polymers were spin coated on to the GaN nanoneedles. The one peak in the electroluminescence spectrum originated from the MEH-PPV layer owing to the different potential barriers of electrons and holes at its interface with the GaN nanoneedles. However, the photoluminescence spectrum showed peaks due to both GaN nanoneedles and MEH-PPV. Such hybrid structures, suitably developed, might be able to improve the efficiency of optoelectronic devices.

  10. Increasing Shareholders Value through NPV-Negative Projects

    Directory of Open Access Journals (Sweden)

    Paweł Mielcarz

    2010-10-01

    Full Text Available The concept of Net Present Value (NPV is a widely accepted tool for verification of financial rationality of planned investment projects. Projects with positive NPV increase a company's value. Similarly, those with negative NPV lead to a decline in the value of a business. This article attempts to answer the question: are projects with negative NPV always disadvantageous in terms of maximization of shareholder value and when should an NPV-negative project be considered justified? The authors discuss the issues of project valuation depending on different conditions. First, they briefly summarize the main idea of valuation - the aim of every company is to maximize shareholder value. Contemporary professional texts say that the way to achieve this goal is through projects that can generate a positive Net Present Value. When there are no such investments within reach, the company should pay dividends to its owners. The authors claim that some circumstances justify investments with a negative Net Present Value, as they still produce maximum possible shareholder value. The three model situations where this takes place are: (1 tax on dividends; (2 shareholders' perception of risk; and (3 temporary inefficiency of the markets. Taxes on dividends reduce cashflows for shareholders from distributed dividends. Therefore, they act exactly as an investment with a negative NPV. The authors conclude that this creates an opportunity to maximize shareholder value by comparing this loss with available alternate projects with negative NPV. If the loss of worth, caused by such taxes, is bigger that the negative NPV of possible investments it will be more rational to invest instead of paying dividends. And, according to the authors, a project with a negative NPV leads to maximized shareholder value. In the second situation, the authors point out that some projects may have negative fundamental (intrinsic value when valuated by the market (diversified owners because

  11. Writable and erasable PPV medium by irradiation at 365 nm

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyuki [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)], E-mail: h-mochizuki@aist.go.jp; Mizokuro, Toshiko; Tanigaki, Nobutaka; Hiraga, Takashi [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)

    2008-03-03

    Dopings of vaporized cis-1,2-dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl) ethane (CMTE) into poly(methyl methacrylate) (PMMA), polystyrene, and polycarbonate were performed by a vacuum process, and the doping behaviors of CMTE were evaluated. Among the matrix polymers, PMMA was dispersed CMTE densely in its surface region. By using the CMTE-doped PMMA, we could fabricate a novel rewritable medium: a multi-layered film was prepared from over-coating of CMTE-doped PMMA onto poly(p-phenylene vinylene) (PPV) film, which set on a transparent substrate. Image storage could be performed upon irradiation at 365 nm at the side of CMTE/PMMA layer: color of the irradiated area changed a light yellow to a red due to photo-isomerization of CMTE. Next, upon irradiation at 365 nm at the side of the transparent substrate, PPV emitted a green fluorescence at around 530 nm, and the CMTE absorbed the emission from PPV causing image-erasure based on back-isomerization of CMTE.

  12. A 3-Year Study of Predictive Factors for Positive and Negative Appendicectomies.

    Science.gov (United States)

    Chang, Dwayne T S; Maluda, Melissa; Lee, Lisa; Premaratne, Chandrasiri; Khamhing, Srisongham

    2018-03-06

    Early and accurate identification or exclusion of acute appendicitis is the key to avoid the morbidity of delayed treatment for true appendicitis or unnecessary appendicectomy, respectively. We aim (i) to identify potential predictive factors for positive and negative appendicectomies; and (ii) to analyse the use of ultrasound scans (US) and computed tomography (CT) scans for acute appendicitis. All appendicectomies that took place at our hospital from the 1st of January 2013 to the 31st of December 2015 were retrospectively recorded. Test results of potential predictive factors of acute appendicitis were recorded. Statistical analysis was performed using Fisher exact test, logistic regression analysis, sensitivity, specificity, and positive and negative predictive values calculation. 208 patients were included in this study. 184 patients had histologically proven acute appendicitis. The other 24 patients had either nonappendicitis pathology or normal appendix. Logistic regression analysis showed statistically significant associations between appendicitis and white cell count, neutrophil count, C-reactive protein, and bilirubin. Neutrophil count was the test with the highest sensitivity and negative predictive values, whereas bilirubin was the test with the highest specificity and positive predictive values (PPV). US and CT scans had high sensitivity and PPV for diagnosing appendicitis. No single test was sufficient to diagnose or exclude acute appendicitis by itself. Combining tests with high sensitivity (abnormal neutrophil count, and US and CT scans) and high specificity (raised bilirubin) may predict acute appendicitis more accurately.

  13. CdWO{sub 4}-on-MEH-PPV:PS as a candidate for real-time dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.M. [Laboratory of Polymers and Electronic Properties of Materials, UFOP, 35400-000 (Brazil); Novais, S.M.V.; Silva, E.S.S. [Group of Advanced Ceramic Materials, UFS, 49100-000 (Brazil); Schimitberger, T. [Laboratory of Polymers and Electronic Properties of Materials, UFOP, 35400-000 (Brazil); Macedo, Z.S. [Group of Advanced Ceramic Materials, UFS, 49100-000 (Brazil); Bianchi, R.F., E-mail: bianchi@iceb.ufop.br [Laboratory of Polymers and Electronic Properties of Materials, UFOP, 35400-000 (Brazil)

    2012-10-15

    We report on the investigations about the modification of optical properties induced by X-rays onto film detectors of cadmium tungstate (CdWO{sub 4}), poly[2-methoxy-5(2 Prime -ethylhexyloxy)-p-phenylenevinylene] (MEH-PPV) and polystyrene (PS) This device takes advantage of reduction of spectral overlap between the radioluminescence (RL) of CdWO{sub 4} and the absorption of MEH-PPV as it is exposed to radiation, forming the basis of a new dosimeter that is capable of converting the orange-red radioluminescence of PS:MEH-PPV:CdWO{sub 4} into green. We propose an explanation of the optical processes occurring in MEH-PPV:CdWO{sub 4} in terms of the radiation hardness of CdWO{sub 4} combined to the RL-induced degradation of MEH-PPV. Highlights: Black-Right-Pointing-Pointer Thin composite film dosimeters using a combination of a scintillator crystal and a light-emitting polymer. Black-Right-Pointing-Pointer A X-ray dose detector based on MEH-PPV/CdWO{sub 4} materials which are rarely seen together. Black-Right-Pointing-Pointer A new smart, disposable and easy-to-read organic-inorganic radiation detector.

  14. Morphological, structural and optical properties of MEH-PPV: PC70BM nanocomposite film

    Science.gov (United States)

    Mhamdi, Asya; Sweii, Fatma ben Slama; Saidi, Hamza; Saidi, Faouzi; Bouazizi, Abdelaziz

    2018-05-01

    In this report, the influence of annealing temperature and spin coating speed on the structural and morphological properties of a blend of poly (2-methoxy-5-(2-ethyl-oxy)-p-phenylene-vinylene) (MEH-PPV) and [6-6]-phenyl-C71-butyric acid methyl ester (PC70BM) layer has been investigated. The photoactive layer (MEH-PPV: PC70BM) was deposited on ZnO film deposited on top of indium tin oxide (ITO) substrate by spin-coating. The effect of spin coating speed via atomic force microscope (AFM) leads to conclude that high speed is favorable for a good homogeneity of the film surface and good aggregates dispersion. The optimized structure was studied by varying the annealing temperatures using X-ray diffraction (XRD). The XRD analysis indicates that annealing treatment promoted the ordered aggregation and crystallization of MEH-PPV: PC70BM films. Indeed, the blend ratio effect on the optical properties of MEH-PPV: PC70BM thin film was investigated. While, the effect of incorporation of PC70BM on the optical properties was studied using UV-Vis and photoluminescence (PL) measurement. We conclude that MEH-PPV: PC70BM (1:3) film leads to high charge transfer rate.

  15. Nucleic Acid Amplification Testing and Sequencing Combined with Acid-Fast Staining in Needle Biopsy Lung Tissues for the Diagnosis of Smear-Negative Pulmonary Tuberculosis.

    Science.gov (United States)

    Jiang, Faming; Huang, Weiwei; Wang, Ye; Tian, Panwen; Chen, Xuerong; Liang, Zongan

    2016-01-01

    Smear-negative pulmonary tuberculosis (PTB) is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB) staining of needle biopsy lung tissues for patients with suspected smear-negative PTB. Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR). For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination. Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124). Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB) for the diagnosis of smear-negative were 61.7% (82/133), 100% (48/48), 100% (82/82), 48.5% (48/181), and 71.8% (130/181), respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133), 95.8% (46/48), 98.3% (119/121), and 76.7% (46/60), respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181]) than histological acid-fast staining (71.8% [130/181]), P pulmonary tuberculosis. For patients with positive histological AFB and

  16. Nucleotide sequence of the coat protein gene of the Skierniewice isolate of plum pox virus (PPV)

    International Nuclear Information System (INIS)

    Wypijewski, K.; Musial, W.; Augustyniak, J.; Malinowski, T.

    1994-01-01

    The coat protein (CP) gene of the Skierniewice isolate of plum pox virus (PPV-S) has been amplified using the reverse transcription - polymerase chain reaction (RT-PCR), cloned and sequenced. The nucleotide sequence of the gene and the deduced amino-acid sequences of PPV-S CP were compared with those of other PPV strains. The nucleotide sequence showed very high homology to most of the published sequences. The motif: Asp-Ala-Gly (DAG), important for the aphid transmissibility, was present in the amino-acid sequence. Our isolate did not react in ELISA with monoclonal antibodies MAb06 supposed to be specific for PPV-D. (author). 32 refs, 1 fig., 2 tabs

  17. PP-O and PP-V, Monascus pigment homologues, production, and phylogenetic analysis in Penicillium purpurogenum.

    Science.gov (United States)

    Arai, Teppei; Kojima, Ryo; Motegi, Yoshiki; Kato, Jun; Kasumi, Takafumi; Ogihara, Jun

    2015-12-01

    The production of pigments as secondary metabolites by microbes is known to vary by species and by physiological conditions within a single strain. The fungus strain Penicillium purpurogenum IAM15392 has been found to produce violet pigment (PP-V) and orange pigment (PP-O),Monascus azaphilone pigment homologues, when grown under specific culture conditions. In this study, we analysed PP-V and PP-O production capability in seven strains of P. purpurogenum in addition to strain IAM15392 under specific culture conditions. The pigment production pattern of five strains cultivated in PP-V production medium was similar to that of strain IAM15392, and all violet pigments produced by these five strains were confirmed to be PP-V. Strains that did not produce pigment were also identified. In addition, two strains cultivated in PP-O production medium produced a violet pigment identified as PP-V. The ribosomal DNA (rDNA) internal transcribed spacer (ITS) region sequences from the eight P. purpurogenum strains were sequenced and used to construct a neighbor-joining phylogenetic tree. PP-O and PP-V production of P. purpurogenum was shown to be related to phylogenetic placement based on rDNA ITS sequence. Based on these results, two hypotheses for the alteration of pigment production of P. purpurogenum in evolution were proposed. Copyright © 2015 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  18. Nucleic Acid Amplification Testing and Sequencing Combined with Acid-Fast Staining in Needle Biopsy Lung Tissues for the Diagnosis of Smear-Negative Pulmonary Tuberculosis.

    Directory of Open Access Journals (Sweden)

    Faming Jiang

    Full Text Available Smear-negative pulmonary tuberculosis (PTB is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB staining of needle biopsy lung tissues for patients with suspected smear-negative PTB.Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR. For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM. The sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination.Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124. Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB for the diagnosis of smear-negative were 61.7% (82/133, 100% (48/48, 100% (82/82, 48.5% (48/181, and 71.8% (130/181, respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133, 95.8% (46/48, 98.3% (119/121, and 76.7% (46/60, respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181] than histological acid-fast staining (71.8% [130/181], P < 0.001. Parallel testing of histological AFB staining and PCR showed the

  19. The influence of prostate-specific antigen density on positive and negative predictive values of multiparametric magnetic resonance imaging to detect Gleason score 7-10 prostate cancer in a repeat biopsy setting.

    Science.gov (United States)

    Hansen, Nienke L; Barrett, Tristan; Koo, Brendan; Doble, Andrew; Gnanapragasam, Vincent; Warren, Anne; Kastner, Christof; Bratt, Ola

    2017-05-01

    To evaluate the influence of prostate-specific antigen density (PSAD) on positive (PPV) and negative (NPV) predictive values of multiparametric magnetic resonance imaging (mpMRI) to detect Gleason score ≥7 cancer in a repeat biopsy setting. Retrospective study of 514 men with previous prostate biopsy showing no or Gleason score 6 cancer. All had mpMRI, graded 1-5 on a Likert scale for cancer suspicion, and subsequent targeted and 24-core systematic image-fusion guided transperineal biopsy in 2013-2015. The NPVs and PPVs of mpMRIs for detecting Gleason score ≥7 cancer were calculated (±95% confidence intervals) for PSAD ≤0.1, 0.1-0.2, ≤0.2 and >0.2 ng/mL/mL, and compared by chi-square test for linear trend. Gleason score ≥7 cancer was detected in 31% of the men. The NPV of Likert 1-2 mpMRI was 0.91 (±0.04) with a PSAD of ≤0.2 ng/mL/mL and 0.71 (±0.16) with a PSAD of >0.2 ng/mL/mL (P = 0.003). For Likert 3 mpMRI, PPV was 0.09 (±0.06) with a PSAD of ≤0.2 ng/mL/mL and 0.44 (±0.19) with a PSAD of >0.2 ng/mL/mL (P = 0.002). PSAD also significantly affected the PPV of Likert 4-5 mpMRI lesions: the PPV was 0.47 (±0.08) with a PSAD of ≤0.2 ng/mL/mL and 0.66 (±0.10) with a PSAD of >0.2 ng/mL/mL (P prostate cancer, not only in men with negative mpMRI, but also in men with equivocal imaging. Surveillance, rather than repeat biopsy, may be appropriate for these men. Conversely, biopsies are indicated in men with a high PSAD, even if an mpMRI shows no suspicious lesion, and in men with an mpMRI suspicious for cancer, even if the PSAD is low. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  20. Enhanced luminescence of MEH-PPV through the reduction of chain aggregations by blending 4-cyano-4′-N-heptylbiphenyl

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Kuei-Ting [Institute of Organic and Polymeric Materials, National Taipei University of Technology, No.1, Section 3, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan (R.O.C.) (China); Department of Chemical Engineering, Army Academy, No.750, Longdong Rd., Chung-Li 320, Taiwan (R.O.C.) (China); Chang, Shu-Mei; Li, Guo-Yuan [Institute of Organic and Polymeric Materials, National Taipei University of Technology, No.1, Section 3, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan (R.O.C.) (China); Liu, Wei-Ren, E-mail: WRLiu1203@gmail.com [Department of Chemical Engineering, R and D Center for Membrane Center, Chung Yuan Christian University, Chung Li, Taiwan (China)

    2015-02-15

    In this study, we report the electroluminescence and photoluminescence of poly[2-methoxy-5-(2-ethylhexyloxy)-p-phenylene vinylene] (MEH-PPV) and 4-cyano-4′-N-heptylbiphenyl (7CB) blends in the ratios of 0–90 wt% by drop-coating processes. The corresponding characterization of polarized optical microscope, electroluminescence, photoluminescence and atomic force microscope of different blending ratios of MEH-PPV/7CB are systematically carried out in this study. The optimal composition of 6/4 ratio in MEH-PPV/7CB exhibit the highest luminescence, which is almost ten times than that of pure MEH-PPV due to the fact that 7CB could be a barrier to avoid the aggression of MEH-PPV. The novel blending system demonstrate a potential approach for synthesizing the MEH-PPV/7CB composite film for electroluminescent device applications. - Highlights: • We propose a novel blending system of MEH-PPV/7CB system. • Controlling the alignment of polymer. • Avoid the aggression of MEH-PPV. • The luminescence intensity of blend film can be enhanced by 10 times. • A potential approach for electroluminescent device applications.

  1. A live-attenuated chimeric porcine circovirus type 2 (PCV2) vaccine is transmitted to contact pigs but is not upregulated by concurrent infection with porcine parvovirus (PPV) and porcine reproductive and respiratory syndrome virus (PRRSV) and is efficacious in a PCV2b-PRRSV-PPV challenge model.

    Science.gov (United States)

    Opriessnig, T; Shen, H G; Pal, N; Ramamoorthy, S; Huang, Y W; Lager, K M; Beach, N M; Halbur, P G; Meng, X J

    2011-08-01

    The live chimeric porcine circovirus type 2 (PCV2) vaccine with the capsid gene of the emerging subtype 2b cloned in the genomic backbone of the nonpathogenic PCV1 is attenuated in vivo and induces protective immunity against PCV2. To further determine the safety and efficacy of this experimental vaccine, we tested for evidence of pig-to-pig transmission by commingling nonvaccinated and vaccinated pigs, determined potential upregulation by simultaneous vaccination and infection with porcine parvovirus (PPV) and porcine reproductive and respiratory syndrome virus (PRRSV), and determined vaccine efficacy by challenging pigs 4 weeks after vaccination with PCV2b, PRRSV, and PPV. Forty-six 21-day-old, PCV2-naïve pigs were randomly assigned to one of six groups. Twenty-nine of 46 pigs were challenged with PCV2b, PRRSV, and PPV at day 28, 8/46 remained nonvaccinated and nonchallenged and served as negative controls, and 9/46 remained nonchallenged and served as vaccination controls. All animals were necropsied at day 49. PCV1-PCV2 viremia was detected in nonvaccinated contact pigs commingled with vaccinated pigs, indicating pig-to-pig transmission; however, PCV1-PCV2 DNA levels remained low in all vaccinated and contact pigs regardless of concurrent infection. Finally, vaccination 28 days before challenge resulted in significantly (P attenuated chimeric PCV2 vaccine, although transmissible to contact pigs, remains attenuated in pigs concurrently infected with PRRSV and PPV and induces protective immunity against PCV2b when it is administered 28 days before PCV2 exposure.

  2. A Live-Attenuated Chimeric Porcine Circovirus Type 2 (PCV2) Vaccine Is Transmitted to Contact Pigs but Is Not Upregulated by Concurrent Infection with Porcine Parvovirus (PPV) and Porcine Reproductive and Respiratory Syndrome Virus (PRRSV) and Is Efficacious in a PCV2b-PRRSV-PPV Challenge Model▿

    Science.gov (United States)

    Opriessnig, T.; Shen, H. G.; Pal, N.; Ramamoorthy, S.; Huang, Y. W.; Lager, K. M.; Beach, N. M.; Halbur, P. G.; Meng, X. J.

    2011-01-01

    The live chimeric porcine circovirus type 2 (PCV2) vaccine with the capsid gene of the emerging subtype 2b cloned in the genomic backbone of the nonpathogenic PCV1 is attenuated in vivo and induces protective immunity against PCV2. To further determine the safety and efficacy of this experimental vaccine, we tested for evidence of pig-to-pig transmission by commingling nonvaccinated and vaccinated pigs, determined potential upregulation by simultaneous vaccination and infection with porcine parvovirus (PPV) and porcine reproductive and respiratory syndrome virus (PRRSV), and determined vaccine efficacy by challenging pigs 4 weeks after vaccination with PCV2b, PRRSV, and PPV. Forty-six 21-day-old, PCV2-naïve pigs were randomly assigned to one of six groups. Twenty-nine of 46 pigs were challenged with PCV2b, PRRSV, and PPV at day 28, 8/46 remained nonvaccinated and nonchallenged and served as negative controls, and 9/46 remained nonchallenged and served as vaccination controls. All animals were necropsied at day 49. PCV1-PCV2 viremia was detected in nonvaccinated contact pigs commingled with vaccinated pigs, indicating pig-to-pig transmission; however, PCV1-PCV2 DNA levels remained low in all vaccinated and contact pigs regardless of concurrent infection. Finally, vaccination 28 days before challenge resulted in significantly (P attenuated chimeric PCV2 vaccine, although transmissible to contact pigs, remains attenuated in pigs concurrently infected with PRRSV and PPV and induces protective immunity against PCV2b when it is administered 28 days before PCV2 exposure. PMID:21653745

  3. The relationship between the violet pigment PP-V production and intracellular ammonium level in Penicillium purpurogenum.

    Science.gov (United States)

    Kojima, Ryo; Arai, Teppei; Matsufuji, Hiroshi; Kasumi, Takafumi; Watanabe, Taisuke; Ogihara, Jun

    2016-12-01

    Penicillium purpurogenum is the fungus that produces an azaphilone pigment. However, details about the pigment biosynthesis pathway are unknown. The violet pigment PP-V is the one of the main pigments biosynthesized by this fungus. This pigment contains an amino group in a pyran ring as its core structure. We focused on this pigment and examined the relationship between intracellular ammonium concentration and pigment production using glutamine as a nitrogen source. The intracellular ammonium level decreased about 1.5-fold in conditions favoring PP-V production. Moreover, P. purpurogenum was transferred to medium in which it commonly produces the related pigment PP-O after cultivating it in the presence or absence of glutamine to investigate whether this fungus biosynthesizes PP-V using surplus ammonium in cells. Only mycelia cultured in medium containing 10 mM glutamine produced the violet pigment, and simultaneously intracellular ammonium levels decreased under this condition. From comparisons of the amount of PP-V that was secreted with quantity of surplus intracellular ammonium, it is suggested that P. purpurogenum maintains ammonium homeostasis by excreting waste ammonium as PP-V.

  4. Ultrafast Charge Photogeneration in MEH-PPV Charge-Transfer Complexes

    NARCIS (Netherlands)

    Bakulin, Artem A.; Paraschuk, Dmitry Yu; Pshenichnikov, Maxim S.; van Loosdrecht, Paul H. M.; Corkum, P; DeSilvestri, S; Nelson, KA; Riedle, E; Schoenlein, RW

    2009-01-01

    Visible-pump - IR-probe spectroscopy is used to study the ultrafast charge dynamics in MEH-PPV based charge-transfer complexes and donor-acceptor blends. Transient anisotropy of the polymer polaron band provides invaluable insights into excitation localisation and charge-transfer pathways.

  5. [Photovoltaic character of organic EL devices MEH-PPV/Alq3].

    Science.gov (United States)

    Lin, Peng; Liang, Chun-Jun; Deng, Zhen-Bo; Xiong, De-Ping; Wang, Li; Zhang, Zhi-Feng; Zhang, Xi-Qing

    2005-01-01

    An organic photovoltaic(PV) cell, ITO/MEH-PPV/Alq3/LiF/Al, was fabricated. The MEH-PPV and Alq3 are the electron-acceptor and donor in the cell, respectively. The respond region matchs the adsorption of Alq3 film. Under UV light with 0.5 mW x cm(-2), the cell shows a short-circuit current of 2.4 microA x cm(-2), open-circuit voltage of 2.6 V, a fill factor of 0.71, and a power conversion efficiency of 0.9%. It was found that the PV cell indicates electroluminescence (EL) performance and could emit orange light at DC voltage. The maximum luminance is about 1 000 cd x cm(-2) at 15 V.

  6. Blue shift in the luminescence spectra of MEH-PPV films containing ZnO nanoparticles

    International Nuclear Information System (INIS)

    Ton-That, Cuong; Phillips, Matthew R.; Nguyen, Thien-Phap

    2008-01-01

    Luminescence properties of nanocomposites consisting of ZnO nanoparticles in a conjugated polymer, poly [2-methoxy-5-(2'-ethyl hexyloxy)-phenylene vinylene] (MEH-PPV), were investigated. Photoluminescence measurements reveal a blue shift in the emission spectrum of MEH-PPV upon incorporation of ZnO nanoparticles into the polymer film while the emission is increasingly quenched with increasing ZnO concentration. In contrast, the structure of the polymer and its conjugation length are not affected by the presence of ZnO nanoparticles (up to 16 wt% ZnO) as revealed by Raman spectroscopy. The blue shift and photoluminescence quenching are explained by the separation of photogenerated electron-hole pairs at the MEH-PPV/ZnO interface and the charging of the nanoparticles

  7. Surface structure, optoelectronic properties and charge transport in ZnO nanocrystal/MDMO-PPV multilayer films.

    Science.gov (United States)

    Lian, Qing; Chen, Mu; Mokhtar, Muhamad Z; Wu, Shanglin; Zhu, Mingning; Whittaker, Eric; O'Brien, Paul; Saunders, Brian R

    2018-05-07

    Blends of semiconducting nanocrystals and conjugated polymers continue to attract major research interest because of their potential applications in optoelectronic devices, such as solar cells, photodetectors and light-emitting diodes. In this study we investigate the surface structure, morphological and optoelectronic properties of multilayer films constructed from ZnO nanocrystals (NCs) and poly[2-methoxy-5-(3',7'-dimethyloctyloxy)-1,4-phenylenevinylene] (MDMO-PPV). The effects of layer number and ZnO concentration (C ZnO ) used on the multilayer film properties are investigated. An optimised solvent blend enabled well-controlled layers to be sequentially spin coated and the construction of multilayer films containing six ZnO NC (Z) and MDMO-PPV (M) layers (denoted as (ZM) 6 ). Contact angle data showed a strong dependence on C ZnO and indicated distinct differences in the coverage of MDMO-PPV by the ZnO NCs. UV-visible spectroscopy showed that the MDMO-PPV absorption increased linearly with the number of layers in the films and demonstrates highly tuneable light absorption. Photoluminescence spectra showed reversible quenching as well as a surprising red-shift of the MDMO-PPV emission peak. Solar cells were constructed to probe vertical photo-generated charge transport. The measurements showed that (ZM) 6 devices prepared using C ZnO = 14.0 mg mL -1 had a remarkably high open circuit voltage of ∼800 mV. The device power conversion efficiency was similar to that of a control bilayer device prepared using a much thicker MDMO-PPV layer. The results of this study provide insight into the structure-optoelectronic property relationships of new semiconducting multilayer films which should also apply to other semiconducting NC/polymer combinations.

  8. Hybrid electroluminescent device based on MEH-PPV and ZnO

    Energy Technology Data Exchange (ETDEWEB)

    Hewidy, Dina; Gadallah, A.-S.; Fattah, G. Abdel

    2017-02-15

    Hybrid organic/inorganic electroluminescent device based on the structure of glass/ITO/PEDOT:PSS/MEH-PPV/ZnO/ZnO submicrorods/Al has been manufactured. Spin coating has been used to deposit both PEDOT:PSS and MEH-PPV. Two-step process has been used to synthesis ZnO submicrorods, namely, spin coating and chemical bath deposition. Changing the dimensions of the ZnO submicrorods in this layer structure has been investigated to improve the performance of the organic/inorganic electroluminescence device. Such layer structure provides electroluminescence with narrow emission bands due to a high gain with this structure. X-ray diffraction patterns and scanning electron microscope images show that ZnO submicrorods have hexagon structure. Current-voltage curve for the structure has been reported. Electroluminescence curves (electroluminescence intensity versus wavelength) at different bias voltages have been presented and these results show narrowing in full width at half maximum in the spectra at high current density compared to photoluminescence excitation. The narrowing in the spectrum has been explained. - Highlights: • Manufacturing of MEH-PPV and ZnO electroluminescent device has been reported. • Spin coating and chemical bath deposition have been used for preparation of ZnO. • SEM images and X-ray diffraction of ZnO have been presented. • Current-voltage curves and electroluminescent measurements have been reported.

  9. Materials and Devices Research of PPV-ZnO Nanowires for Heterojunction Solar Cells

    Directory of Open Access Journals (Sweden)

    Zhang Xiao-Zhou

    2012-01-01

    Full Text Available Bulk heterojunction photovoltaic devices, which use the conjugated polymer poly(2-methoxyl-5-(2′-ethylhexyloxy-1,4-phenylenevinylene (MEH-PPV as the electron donor and crystalline ZnO nanowires as the electron acceptor, have been studied in this work. The ZnO nanowires were prepared through a chemical vapor deposition mechanism. The dissolved MEH-PPV polymer was spin-coated onto the nanowires. The scanning electron microscope images showed that the ZnO nanowires were covered with a single layer of the polymer, and these materials were used to design a heterojunction solar cell. This solar cell displayed improved performance compared with the devices that were made from only the MEH-PPV polymer. This observed improvement is correlated with the improved electron transport that is perpendicular to the plane of the film. A solar power conversion efficiency of 1.37% was achieved under an AM1.5 illumination.

  10. Investigation on the Optical and Surface Morphology of Conjugated Polymer MEH-PPV:ZnO Nanocomposite Thin Films

    Directory of Open Access Journals (Sweden)

    Nurul Zayana Yahya

    2012-01-01

    Full Text Available Thin films of red color poly(2-methoxy-5(2′-ethylhexyloxy-phenylene vinylene (MEH-PPV containing different weight percent of ZnO nanoparticles were obtained by spin-coating techniques. The MEH-PPV:ZnO solutions were spin coated onto silicon and glass substrates. The spun MEH-PPV:ZnO thin films were then used to investigate optical properties by using ultraviolet-visible spectrometer (UV-Vis and photoluminescence spectrophotometer (PL. The morphologies were investigated by using field emission scanning electron microscopy (FESEM, while the identification of ZnO in the final product was determined by using energy-dispersive X-ray spectroscopy (EDS. The UV-Vis absorption band increases, while the optical bandgap decreases when the amount of ZnO nanoparticles increases. ZnO nanoparticles apparently have no effect on the conjugation segments of MEH-PPV. PL spectra show that the emission peak increases and slightly red shift as ZnO concentration increases. Based on SEM images of MEH-PPV:ZnO nanocomposite thin films, ZnO nanoparticles form agglomerated regions.

  11. The Value of a Checklist for Child Abuse in Out-of-Hours Primary Care: To Screen or Not to Screen.

    Science.gov (United States)

    Schouten, Maartje Cm; van Stel, Henk F; Verheij, Theo Jm; Houben, Michiel L; Russel, Ingrid Mb; Nieuwenhuis, Edward Es; van de Putte, Elise M

    2017-01-01

    To assess the diagnostic value of the screening instrument SPUTOVAMO-R2 (checklist, 5 questions) for child abuse at Out-of-hours Primary Care locations (OPC), by comparing the test outcome with information from Child Protection Services (CPS). Secondary, to determine whether reducing the length of the checklist compromises diagnostic value. All children (abuse (32.8%). The positive predictive value (PPV) of the checklist for child abuse was 8.3 (95% CI 3.9-15.2). The negative predictive value (NPV) was 99.1 (98.8-99.3), with 52 false negatives. When the length of the checklist was reduced to two questions closely related to the medical process (SPUTOVAMO-R3), the PPV was 9.1 (3.7-17.8) and the NPV 99.1 (98.7-99.3). These two questions are on the injury in relation to the history, and the interaction between child and parents. The checklist SPUTOVAMO-R2 has a low detection rate of child abuse within the OPC setting, and a high false positive rate. Therefore, we recommend to use the shortened checklist only as a tool to increase the awareness of child abuse and not as a diagnostic instrument.

  12. PPV analysis and tension of spectral peak in an X radiation equipment for dosemeter calibration; Analise do PPV e tensao de pico espectral em um equipamento de raios-X para calibracao de dosimetros

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, P.M.C.; Santana, P.C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem; Lacerda, M.A.S.; Silva, T.A. da, E-mail: pmco@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-07-01

    Dosimetry laboratories around the world try to achieve metrology consistency between the X-rays beams for therapy and diagnostic detectors calibration. One of the parameters to characterize X-ray beam is the practical peak voltage (PPV) assessment. In this work were evaluated the PPV and spectral peak voltage in the potential constant X-ray equipment, that result in a mean difference of 1.4 %. (author)

  13. Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.

    Science.gov (United States)

    Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu

    2017-09-01

    The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  14. Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients.

    Science.gov (United States)

    Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes

    2011-01-01

    To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.

  15. Resistance to Plum Pox Virus (PPV) in apricot (Prunus armeniaca L.) is associated with down-regulation of two MATHd genes.

    Science.gov (United States)

    Zuriaga, Elena; Romero, Carlos; Blanca, Jose Miguel; Badenes, Maria Luisa

    2018-01-27

    Plum pox virus (PPV), causing Sharka disease, is one of the main limiting factors for Prunus production worldwide. In apricot (Prunus armeniaca L.) the major PPV resistance locus (PPVres), comprising ~ 196 kb, has been mapped to the upper part of linkage group 1. Within the PPVres, 68 genomic variants linked in coupling to PPV resistance were identified within 23 predicted transcripts according to peach genome annotation. Taking into account the predicted functions inferred from sequence homology, some members of a cluster of meprin and TRAF-C homology domain (MATHd)-containing genes were pointed as PPV resistance candidate genes. Here, we have characterized the global apricot transcriptome response to PPV-D infection identifying six PPVres locus genes (ParP-1 to ParP-6) differentially expressed in resistant/susceptible cultivars. Two of them (ParP-3 and ParP-4), that encode MATHd proteins, appear clearly down-regulated in resistant cultivars, as confirmed by qRT-PCR. Concurrently, variant calling was performed using whole-genome sequencing data of 24 apricot cultivars (10 PPV-resistant and 14 PPV-susceptible) and 2 wild relatives (PPV-susceptible). ParP-3 and ParP-4, named as Prunus armeniaca PPVres MATHd-containing genes (ParPMC), are the only 2 genes having allelic variants linked in coupling to PPV resistance. ParPMC1 has 1 nsSNP, while ParPMC2 has 15 variants, including a 5-bp deletion within the second exon that produces a frameshift mutation. ParPMC1 and ParPMC2 are adjacent and highly homologous (87.5% identity) suggesting they are paralogs originated from a tandem duplication. Cultivars carrying the ParPMC2 resistant (mutated) allele show lack of expression in both ParPMC2 and especially ParPMC1. Accordingly, we hypothesize that ParPMC2 is a pseudogene that mediates down-regulation of its functional paralog ParPMC1 by silencing. As a whole, results strongly support ParPMC1 and/or ParPMC2 as host susceptibility genes required for PPV infection which

  16. Guided in Situ Polymerization of MEH-PPV in Mesoporous Titania Photoanodes.

    Science.gov (United States)

    Minar, Norma K; Docampo, Pablo; Fattakhova-Rohlfing, Dina; Bein, Thomas

    2015-05-20

    Incorporation of conjugated polymers into porous metal oxide networks is a challenging task, which is being pursued via many different approaches. We have developed the guided in situ polymerization of poly(2-methoxy-5-(2'-ethylhexyloxy)-p-phenylenevinylene) (MEH-PPV) in porous titania films by means of surface functionalization. The controlled polymerization via the Gilch route was induced by an alkoxide base and by increasing the temperature. The selected and specially designed surface-functionalizing linker molecules mimic the monomer or its activated form, respectively. In this way, we drastically enhanced the amount of MEH-PPV incorporated into the porous titania phase compared to nonfunctionalized samples by a factor of 6. Additionally, photovoltaic measurements were performed. The devices show shunting or series resistance limitations, depending on the surface functionalization prior to in situ polymerization of MEH-PPV. We suggest that the reason for this behavior can be found in the orientation of the grown polymer chains with respect to the titania surface. Therefore, the geometry of the anchoring via the linker molecules is relevant for exploiting the full electronic potential of the conjugated polymer in the resulting hybrid composite. This observation will help to design future synthesis methods for new hybrid materials from conjugated polymers and n-type semiconductors to take full advantage of favorable electronic interactions between the two phases.

  17. Organic–inorganic hybrid nanocomposite for enhanced photo-sensing of PFO-DBT:MEH-PPV:PC{sub 71}BM blend-based photodetector

    Energy Technology Data Exchange (ETDEWEB)

    Zafar, Qayyum, E-mail: qayyumzafar@siswa.um.edu.my; Najeeb, Mansoor Ani, E-mail: animansoor@um.edu.my [University of Malaya, Low Dimensional Materials Research Centre (LDMRC), Department of Physics, Faculty of Science (Malaysia); Ahmad, Zubair, E-mail: zubairtarar@qu.edu.qa [Qatar University, Department of Electrical Engineering, College of Engineering (Qatar); Sulaiman, Khaulah, E-mail: khaulah@um.edu.my [University of Malaya, Low Dimensional Materials Research Centre (LDMRC), Department of Physics, Faculty of Science (Malaysia)

    2015-09-15

    The sensing parameters of previously reported PFO-DBT:MEH-PPV:PC{sub 71}BM ternary blend-based organic photodetector have been improved in the present study. Improvement has been successfully demonstrated by doping TiO{sub 2} nanoparticles in the PEDOT:PSS thin film. TiO{sub 2} nanoparticles of 50, 100 and 250 nm diameters have initially been dispersed in PEDOT:PSS, and the resulting suspension has been spun coated on glass substrates and subjected to UV/vis and PL study. Thin film of PEDOT:PSS–TiO{sub 2} (100 nm) has shown maximum quenching in PL spectra, along with fairly good visible-light absorption. For further studies, 5 wt% TiO{sub 2} (100 nm) nanoparticles dispersion in PEDOT:PSS has been utilized for the fabrication of ITO/PEDOT:PSS–TiO{sub 2}/PFO-DBT:MEH-PPV:PC{sub 71}BM/Al photodiode. The PEDOT:PSS–TiO{sub 2} suspension has been spun coated onto the ITO substrates primarily and annealed to densify the film by vaporizing water contents in the film. A ternary blend of PFO-DBT:MEH-PPV:PC{sub 71}BM in optimized volumetric ratio has been sequentially spun-cast to serve as a photoactive film. Significantly improved values of the sensing parameters such as responsivity (4 mA/W) and photo-to-dark current ratio (∼6.4 × 10{sup 4}) have also been found. Response/recovery times of the fabricated sensor remain almost the same (<1 s) as previously reported for PFO-DBT:MEH-PPV:PC{sub 71}BM ternary blend.

  18. Photophysics of conjugated polymers: interplay between Förster energy migration and defect concentration in shaping a photochemical funnel in PPV.

    Science.gov (United States)

    Saini, Sangeeta; Bagchi, Biman

    2010-07-21

    Recent single molecule experiments have suggested the existence of a photochemical funnel in the photophysics of conjugated polymers, like poly[2-methoxy-5-(2'-ethylhexyl)oxy-1,4-phenylenevinylene] (MEH-PPV). The funnel is believed to be a consequence of the presence of conformational or chemical defects along the polymer chain and efficient non-radiative energy transfer among different chromophore segments. Here we address the effect of the excitation energy dynamics on the photophysics of PPV. The PPV chain is modeled as a polymer with the length distribution of chromophores given either by a Gaussian or by a Poisson distribution. We observe that the Poisson distribution of the segment lengths explains the photophysics of PPV better than the Gaussian distribution. A recently proposed version of an extended 'particle-in-a-box' model is used to calculate the exciton energies and the transition dipole moments of the chromophores, and a master equation to describe the excitation energy transfer among different chromophores. The rate of energy transfer is assumed to be given here, as a first approximation, by the well-known Förster expression. The observed excitation population dynamics confirms the photochemical funneling of excitation energy from shorter to longer chromophores of the polymer chain. The time scale of spectral shift and energy transfer for our model polymer, with realistic values of optical parameters, is in the range of 200-300 ps. We find that the excitation energy may not always migrate towards the longest chromophore segments in the polymer chain as the efficiency of energy transfer between chromophores depends on the separation distance between the two and their relative orientation.

  19. Effect of intravitreal injection of Conbercept before PPV on complications and visual recovery in patients with PDR

    Directory of Open Access Journals (Sweden)

    Shao-Bing Lin

    2018-05-01

    Full Text Available AIM: To analyze the effect of intravitreal injection of Conbercept before pars plana vitrectomy(PPVon complications and visual recovery in patients with proliferative diabetic retinopathy(PDR. METHODS: Totally 94 patients with PDR(monocular onsetwere randomly divided into the experimental group(n=47and the control group(n=47. All patients were treated by PPV. The experimental group was treated with intravitreal injection of conbercept at 5-7d before PPV while the control group was not given the intervention. The surgical time, surgical procedures, complications and visual recovery in the two groups were observed and statistically analyzed. RESULTS: The operating time of PPV for the experimental group was significantly shorter than that for the control group(72.33±15.71min vs 91.06±19.29min, PPPPCONCLUSION: The intravitreal injection of conbercept before PPV has a positive effect on reducing the incidence of intraoperative complications and promoting postoperative visual recovery in patients with PDR.

  20. Electrically conductive polyaniline as hole-injection layer for MEH-PPV:BT based polymer light emitting diodes

    International Nuclear Information System (INIS)

    Mohsennia, M.; Bidgoli, M. Massah; Boroumand, F. Akbari; Nia, A. Mohsen

    2015-01-01

    Graphical abstract: The PANI prepared at 15 °C with higher electrical conductivity has been used as hole-injection layer (HIL) in polymer light emitting diodes (PLEDs) with structure of ITO/PANI/MEHPPV:BT/Al. - Highlights: • Polyaniline (PANI) was synthesized at different temperatures (5, 10, 15, 20 and 25 °C). • The PANI sample with higher electrical conductivity was used as HIL in the PLED devices. • The PANI injection layer yielded higher current and lower turn-on voltage. • The effect of MEH-PPV:BT weight ratio on the PLED performance has been also investigated. • The J–V characteristics of the devices have been explained by FN tunneling model. - Abstract: Polyaniline (PANI) was synthesized by oxidative polymerization of aniline at different temperatures (5, 10, 15, 20 and 25 °C). The influence of polymerization temperature on sheet resistance of PANI was investigated, and the one prepared at 15 °C which showed lowest resistivity was chosen for further analysis. PANI was subsequently used as hole-injection layer (HIL) in polymer light emitting diodes (PLEDs) with structure of poly(ethylene terephthalate) (PET)/indium tin oxide (ITO)/PANI/MEH-PPV:BT/aluminum (Al). The PLEDs with emission layer made from a blend of poly [2-methoxy-5-(2′-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) and an electron transporting material, benzothiadiazole (BT), were fabricated at room conditions without using glove boxes. Our results showed an improvement in performance of our PANI-based fabricated PLEDs (PET/ITO/PANI/MEH-PPV:BT/Al) compared to the conventional devices that use poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PET/ITO/PEDOT:PSS/MEH-PPV:BT/Al) as their HIL. The hole injection barrier height (φ) of the fabricated PLEDs were then estimated using the Fowler–Nordheim (FN) field-emission tunneling theory and revealed that the barrier height decreases by increasing the BT concentration in the MEH-PPV:BT blend layer

  1. HPV E6/E7 mRNA Testing Is More Specific than Cytology in Post-Colposcopy Follow-Up of Women with Negative Cervical Biopsy

    Science.gov (United States)

    Sørbye, Sveinung Wergeland; Arbyn, Marc; Fismen, Silje; Gutteberg, Tore Jarl; Mortensen, Elin Synnøve

    2011-01-01

    Background In Norway, women with negative or low-grade cervical biopsies (normal/CIN1) are followed up after six months in order to decide on further follow-up or recall for screening at three-year intervals. A high specificity and positive predictive value (PPV) of the triage test is important to avoid unnecessary diagnostic and therapeutic procedures whereas a low risk of high-grade disease among triage negative women assures safety. Materials and Methods At the University Hospital of North Norway, cytology and the HPV mRNA test PreTect HPV-Proofer, detecting E6/E7 mRNA from HPV types 16, 18, 31, 33 and 45, are used in post-colposcopy follow-up of women with negative or low-grade biopsy. In this study, women with negative biopsy after high grade cytology (ASC-H/HSIL) and/or positive HPV mRNA test in the period 2005–2009 were included (n = 520). Histologically confirmed cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) was used as study endpoint. Results Of 520 women with negative or low-grade biopsy, 124 women (23.8%) had CIN2+ in follow-up biopsy. The sensitivity and specificity of the HPV mRNA test were 89.1% (95% CI, 80.1–98.1) and 92.5% (95% CI, 88.2–96.7), respectively. The ratios of sensitivity, specificity and PPV of HPV mRNA testing compared to repeat cytology for finding CIN2+ was 1.05 (95% CI: 0.92–1.21), 1.21 (95% CI: 1.12–1.32), and 1.49 (95% CI: 1.20–1.86), respectively. The PPV of mRNA was 77.3% (95% CI, 59.8–94.8) in women aged 40 or older. Conclusion Women with negative cervical biopsy require follow-up before resumption of routine screening. Post-colposcopy HPV mRNA testing was as sensitive but more specific than post-colposcopy cytology. In addition, the HPV mRNA test showed higher PPV. A positive mRNA test post-colposcopy could justify treatment in women above 40 years. PMID:21998748

  2. Increasing the luminous efficiency of an MEH-PPV based PLED using salmon DNA and single walled carbon nanotube

    International Nuclear Information System (INIS)

    Madhwal, Devinder; Singh, Inderpreet; Kumar, Jitender; Bhatia, C.S.; Bhatnagar, P.K.; Mathur, P.C.

    2011-01-01

    The combined effect of a salmon deoxyribonucleic acid (DNA)-based electron blocking layer and a single walled carbon nanotube (SWCNT) composite-based electron transport layer on the performance of a poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) polymer light emitting diode (PLED) has been examined. The SWCNT network in the composite layer improves electron injection from cathode and the DNA blocks these high mobility electrons at the electron blocking layer-polymer interface, leading to high luminance from the device. The luminous efficiency of the PLED is increased ∼20 times compared to that of a PLED using only MEH-PPV. - Highlights: → We report fabrication of a high luminous efficiency MEH-PPV based polymer LED. → Salmon DNA-CTMA layer is used to block injected electrons in the polymer layer. → MEH-PPV-SWCNT composite is used to transport electrons in the polymer layer. → The luminous efficiency of the polymer LED thereby improves about 20 times.

  3. Negative values of quasidistributions and quantum wave and number statistics

    Science.gov (United States)

    Peřina, J.; Křepelka, J.

    2018-04-01

    We consider nonclassical wave and number quantum statistics, and perform a decomposition of quasidistributions for nonlinear optical down-conversion processes using Bessel functions. We show that negative values of the quasidistribution do not directly represent probabilities; however, they directly influence measurable number statistics. Negative terms in the decomposition related to the nonclassical behavior with negative amplitudes of probability can be interpreted as positive amplitudes of probability in the negative orthogonal Bessel basis, whereas positive amplitudes of probability in the positive basis describe classical cases. However, probabilities are positive in all cases, including negative values of quasidistributions. Negative and positive contributions of decompositions to quasidistributions are estimated. The approach can be adapted to quantum coherence functions.

  4. The diagnostic value of [18F]FDG PET for the detection of chronic osteomyelitis and implant-associated infection

    International Nuclear Information System (INIS)

    Wenter, Vera; Albert, Nathalie L.; Lehner, Sebastian; Fendler, Wolfgang P.; Bartenstein, Peter; Mueller, Jan-Phillip; Friederichs, Jan; Militz, Matthias; Hungerer, Sven; Cyran, Clemens C.; Hacker, Marcus

    2016-01-01

    The diagnosis of osteomyelitis and implant-associated infections in patients with nonspecific laboratory or radiological findings is often unsatisfactory. We retrospectively evaluated the contributions of [ 18 F]FDG PET and [ 18 F]FDG PET/CT to the diagnosis of osteomyelitis and implant-associated infections, enabling timely and appropriate decision-making for further therapy options. [ 18 F]FDG PET or PET/CT was performed in 215 patients with suspected osteomyelitis or implant-associated infections between 2000 and 2013. We assessed the diagnostic accuracy of both modalities together and separately with reference to intraoperative microbial findings, with a mean clinical follow-up of 69 ± 49 months. Infections were diagnosed clinically in 101 of the 215 patients. PET and PET/CT scans revealed 87 true-positive, 76 true-negative, 38 false-positive, and 14 false-negative results, indicating a sensitivity of 86 %, a specificity of 67 %, a positive predictive value (PPV) of 70 %, a negative predictive value (NPV) of 84 % and an accuracy of 76 %. The sensitivity of PET/CT was 88 %, but specificity, PPV, NPV and accuracy (76 %, 76 %, 89 % and 82 %, respectively) were higher than those of stand-alone PET. [ 18 F]FDG PET is able to identify with high sensitivity the presence of osteomyelitis in orthopaedic surgery patients with nonspecific clinical symptoms of infection. (orig.)

  5. Study of solvent-conjugated polymer interactions by polarized spectroscopy: MEH-PPV and Poly(9,9'-dioctylfluorene-2,7-diyl)

    International Nuclear Information System (INIS)

    Cossiello, Rafael F.; Susman, Mariano D.; Aramendia, Pedro F.; Atvars, Teresa D.Z.

    2010-01-01

    Absorption, emission, and anisotropy measurements were performed on poly-[2-methoxy-5(2'-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV) and poly-(9,9'-dioctylfluorene-2,7-diyl) (PF) solutions of various solvents, and in thin films deposited from them. The good correlation of MEH-PPV absorption and emission energy with Hildebrandt's dispersive parameter indicate that dispersive forces regulate the effective extent of the luminophore. The excitation and the emission spectra of α and β chains can be distinguished in PF solutions using the steady-state anisotropy. PF films show greater memory effect from the solutions from which they were spun than MEH-PPV. Anisotropy of MEH-PPV is very low, both in solutions and in films reflecting efficient energy migration. Anisotropy of PF in solutions and films demonstrates great differences in energy transfer efficiency within the α and β phases, while there is no energy transfer between these chain conformations.

  6. Influence of small-molecule material on performance of polymer solar cells based on MEH-PPV:PCBM blend

    International Nuclear Information System (INIS)

    Liu Xiao-Dong; Xu Zheng; Zhang Fu-Jun; Zhao Su-Ling; Zhang Tian-Hui; Gong Wei; Song Jing-Lu; Kong Chao; Yan Guang; Xu Xu-Rong

    2010-01-01

    In this work, the influence of a small-molecule material, tris(8-hydroxyquinoline) aluminum (Alq 3 ), on bulk heterojunction (BHJ) polymer solar cells (PSCs) is investigated in devices based on the blend of poly(2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene) (MEH-PPV) and [6,6]-phenyl-C 61 -butyric acid methyl ester (PCBM). By doping Alq 3 into MEH-PPV:PCBM solution, the number of MEH-PPV excitons can be effectively increased due to the energy transfer from Alq 3 to MEH-PPV, which probably induces the increase of photocurrent generated by excitons dissociation. However, the low carrier mobility of Alq 3 is detrimental to the efficient charge transport, thereby blocking the charge collection by the respective electrodes. The balance between photon absorption and charge transport in the active layer plays a key role in the performance of PSCs. For the case of 5 wt.% Alq 3 doping, the device performance is deteriorated rather than improved as compared with that of the undoped device. On the other hand, we adopt Alq 3 as a buffer layer instead of commonly used LiF. All the photovoltaic parameters are improved, yielding an 80% increase in power conversion efficiency (PCE) at the optimum thickness (1 nm) as compared with that of the device without any buffer layer. Even for the 5 wt.% Alq 3 doped device, the PCE has a slight enhancement compared with that of the standard device after modification with 1 nm (or 2 nm) thermally evaporated Alq 3 . The performance deterioration of Alq 3 -doped devices can be explained by the low solubility of Alq 3 , which probably deteriorates the bicontinuous D—A network morphology; while the performance improvement of the devices with Alq 3 as a buffer layer is attributed to the increased light harvesting, as well as blocking the hole leakage from MEH-PPV to the aluminum (Al) electrode due to the lower highest occupied molecular orbital (HOMO) level of Alq 3 compared with that of MEH-PPV

  7. The Functional Movement Screen and Injury Risk: Association and Predictive Value in Active Men.

    Science.gov (United States)

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle; Anderson, Morgan K; North, William J; Jones, Bruce H

    2016-02-01

    The Functional Movement Screen (FMS) is a series of 7 tests used to assess the injury risk in active populations. To determine the association of the FMS with the injury risk, assess predictive values, and identify optimal cut points using 3 injury types. Cohort study; Level of evidence, 2. Physically active male soldiers aged 18 to 57 years (N = 2476) completed the FMS. Demographic and fitness data were collected by survey. Medical record data for overuse injuries, traumatic injuries, and any injury 6 months after the FMS assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated along with the receiver operating characteristic (ROC) to determine the area under the curve (AUC) and identify optimal cut points for the risk assessment. Risks, risk ratios (RRs), odds ratios (ORs), and 95% CIs were calculated to assess injury risks. Soldiers who scored ≤14 were at a greater risk for injuries compared with those who scored >14 using the composite score for overuse injuries (RR, 1.84; 95% CI, 1.63-2.09), traumatic injuries (RR, 1.26; 95% CI, 1.03-1.54), and any injury (RR, 1.60; 95% CI, 1.45-1.77). When controlling for other known injury risk factors, multivariate logistic regression analysis identified poor FMS performance (OR [score ≤14/19-21], 2.00; 95% CI, 1.42-2.81) as an independent risk factor for injuries. A cut point of ≤14 registered low measures of predictive value for all 3 injury types (sensitivity, 28%-37%; PPV, 19%-52%; AUC, 54%-61%). Shifting the injury risk cut point of ≤14 to the optimal cut points indicated by the ROC did not appreciably improve sensitivity or the PPV. Although poor FMS performance was associated with a higher risk of injuries, it displayed low sensitivity, PPV, and AUC. On the basis of these findings, the use of the FMS to screen for the injury risk is not recommended in this population because of the low predictive value and misclassification of the

  8. The diagnostic value of [{sup 18}F]FDG PET for the detection of chronic osteomyelitis and implant-associated infection

    Energy Technology Data Exchange (ETDEWEB)

    Wenter, Vera; Albert, Nathalie L.; Lehner, Sebastian; Fendler, Wolfgang P.; Bartenstein, Peter [University of Munich, Department of Nuclear Medicine, Munich (Germany); Mueller, Jan-Phillip; Friederichs, Jan; Militz, Matthias; Hungerer, Sven [BG Trauma Center Murnau, Murnau (Germany); PMU Salzburg, Salzburg (Austria); Cyran, Clemens C. [University of Munich, Institute for Clinical Radiology, Munich (Germany); Hacker, Marcus [University of Vienna, Department of Nuclear Medicine, Vienna (Austria); Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2016-04-15

    The diagnosis of osteomyelitis and implant-associated infections in patients with nonspecific laboratory or radiological findings is often unsatisfactory. We retrospectively evaluated the contributions of [{sup 18}F]FDG PET and [{sup 18}F]FDG PET/CT to the diagnosis of osteomyelitis and implant-associated infections, enabling timely and appropriate decision-making for further therapy options. [{sup 18}F]FDG PET or PET/CT was performed in 215 patients with suspected osteomyelitis or implant-associated infections between 2000 and 2013. We assessed the diagnostic accuracy of both modalities together and separately with reference to intraoperative microbial findings, with a mean clinical follow-up of 69 ± 49 months. Infections were diagnosed clinically in 101 of the 215 patients. PET and PET/CT scans revealed 87 true-positive, 76 true-negative, 38 false-positive, and 14 false-negative results, indicating a sensitivity of 86 %, a specificity of 67 %, a positive predictive value (PPV) of 70 %, a negative predictive value (NPV) of 84 % and an accuracy of 76 %. The sensitivity of PET/CT was 88 %, but specificity, PPV, NPV and accuracy (76 %, 76 %, 89 % and 82 %, respectively) were higher than those of stand-alone PET. [{sup 18}F]FDG PET is able to identify with high sensitivity the presence of osteomyelitis in orthopaedic surgery patients with nonspecific clinical symptoms of infection. (orig.)

  9. Benefit of cerebrospinal fluid spectrophotometry in the assessment of CT scan negative suspected subarachnoid haemorrhage: a diagnostic accuracy study.

    Science.gov (United States)

    Hann, Angus; Chu, Kevin; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2015-01-01

    This study aimed to determine if performing cerebrospinal fluid spectrophotometry in addition to visual inspection detects more ruptured cerebral aneurysms than performing cerebrospinal fluid visual inspection alone in patients with a normal head CT scan but suspected of suffering an aneurysmal subarachnoid haemorrhage (SAH). We performed a single-centre retrospective study of patients presenting to the emergency department of a tertiary hospital who underwent both head CT scan and lumbar puncture to exclude SAH. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of an approach utilising both spectrophotometry and visual inspection (combined approach) was compared to visual inspection alone. A total of 409 patients (mean age 37.8 years, 56.2% female) were recruited and six (1.5%) had a cerebral aneurysm on angiography. The sensitivity of visual inspection was 50% (95% confidence interval [CI]: 12.4-82.6%), specificity was 99% (95% CI: 97.5-99.7%), PPV was 42.9% (95% CI: 10.4-81.3%) and NPV was 99.2% (95% CI: 97.8-99.8%). The combined approach had a sensitivity of 100% (95% CI: 54.1-100%), specificity of 79.7% (95% CI: 75.4-83.5%), PPV of 6.8% (95% CI: 2.6-14.3%) and a NPV of 100% (95% CI: 98.8-100%). The sensitivity of the combined approach was not significantly different to that of visual inspection alone (p=0.25). Visual inspection had a significantly higher specificity than the combined approach (p<0.01). The combined approach detected more cases of aneurysmal SAH than visual inspection alone, however the difference in sensitivity was not statistically significant. Visual xanthochromia should prompt angiography because of a superior specificity and PPV. Due to its reduced sensitivity, caution should be applied when using only visual inspection of the supernatant. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  10. Positive versus negative priming of older adults' generative value: do negative messages impair memory?

    Science.gov (United States)

    Hagood, Elizabeth W; Gruenewald, Tara L

    2018-02-01

    A considerable volume of experimental evidence demonstrates that exposure to aging stereotypes can strongly influence cognitive performance among older individuals. However, whether such effects extend to stereotypes regarding older adults' generative (i.e. contributory) worth is not yet known. The present investigation sought to evaluate the effect of exposure to positive versus negative generative value primes on an important aspect of later life functioning, memory. Participants of age 55 and older (n = 51) were randomly assigned to read a mock news article portraying older individuals as either an asset (positive prime) or a burden (negative prime) to society. Upon reading their assigned article, participants completed a post-priming memory assessment in which they were asked to recall a list of 30 words. Those exposed to the negative prime showed significantly poorer memory performance relative to those exposed to the positive prime (d = 0.75), even when controlling for baseline memory performance and sociodemographic covariates. These findings suggest that negative messages regarding older adults' generative social value impair memory relative to positive ones. Though demonstrated in the short term, these results also point to the potential consequences of long-term exposure to such negative ideologies and may indicate a need to promote more positive societal conceptualizations of older adults' generative worth.

  11. Use of dynamic CT in acute respiratory distress syndrome (ARDS) with comparison of positive and negative pressure ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Helm, Emma; Babyn, Paul [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Talakoub, Omid; Alirezaie, Javad [Ryerson University, Department of Electrical and Computer Engineering, Toronto, ON (Canada); Grasso, Francesco; Engelberts, Doreen; Kavanagh, Brian P. [Hospital for Sick Children and the University of Toronto, Departments of Anesthesia and Critical Care Medicine and the Program in Pulmonary and Experimental Medicine, Toronto (Canada)

    2009-01-15

    Negative pressure ventilation via an external device ('iron lung') has the potential to provide better oxygenation with reduced barotrauma in patients with ARDS. This study was designed to see if oxygenation differences between positive and negative ventilation could be explained by CT. Six anaesthetized rabbits had ARDS induced by repeated saline lavage. Rabbits were ventilated with positive pressure ventilation (PPV) and negative pressure ventilation (NPV) in turn. Dynamic CT images were acquired over the respiratory cycle. A computer-aided method was used to segment the lung and calculate the range of CT densities within each slice. Volumes of ventilated lung and atelectatic lung were measured over the respiratory cycle. NPV was associated with an increased percentage of ventilated lung and decreased percentage of atelectatic lung. The most significant differences in ventilation and atelectasis were seen at mid-inspiration and mid-expiration (ventilated lung NPV=61%, ventilated lung PPV=47%, p<0.001; atelectatic lung NPV=10%, atelectatic lung PPV 19%, p<0.001). Aeration differences were not significant at end-inspiration. Dynamic CT can show differences in lung aeration between positive and negative ventilation in ARDS. These differences would not be appreciated if only static breath-hold CT was used. (orig.)

  12. Value of digital radiography in expiration in detection of pneumothorax

    International Nuclear Information System (INIS)

    Thomsen, L.; Natho, O.; Feigen, U.; Kivelitz, D.; Schulz, U.

    2014-01-01

    Purpose: The purpose of this study was to find out whether pneumothorax detection and exclusion is superior in expiratory digital chest radiography. Materials and Methods: 131 patients with pneumothorax with paired inspiratory and expiratory chest radiographs were analyzed regarding localization and size of pneumothorax. Sensitivity, specificity, negative (npv) and positive predictive value (ppv) as well as the positive (LR+) and negative likelihood ratio (LR-) were determined in a blinded randomized interobserver study with 116 patients. The evaluation was performed by three board-certified radiologists. Results: In 131 patients, there were 139 pneumothoraces, 135 (97.1 %) were located apical, 88 (63.3 %) lateral and 33 (23.7 %) basal. Sensitivity was 99 % for inspiratory and 97 % for expiratory radiographs. The interobserver study yielded a mean sensitivity of 86.1 %/86.1 %, specificity of 97.3 %/93.4 %, npv of 88.7 %/88.5 % and ppv of 96.7 %/92.1 % for inspiration/expiration. For inspiratory radiographs the LR+/LR- were 40.2/0.14 and for expiration 13.9 and 0.15. McNemar-Test showed no significant difference for the detection of pneumothoraces in in-/exspiration. Conclusion: Inspiratory and expiratory digital radiographs are equally suitable for pneumothorax detection. Inspiratory radiographs are recommended as the initial examination of choice for pneumothorax detection, an additional expiratory radiograph is only recommended in doubtful cases. (orig.)

  13. Laboratory and Field Studies of Poly(2,5-bis(N-methyl-N-hexylaminophenylene vinylene (BAM-PPV: A Potential Wash Primer Replacement for Army Military Vehicles

    Directory of Open Access Journals (Sweden)

    Peter Zarras

    2014-09-01

    Full Text Available In this study, an electroactive polymer (EAP, poly(2,5-bis(N-methyl-N- hexylaminophenylene vinylene (BAM-PPV, was tested as an alternative to current hexavalent chromium (Cr(VI-based Army wash primers. BAM-PPV was tested in both laboratory and field studies to determine its adhesive and corrosion-inhibiting properties when applied to steel and aluminum alloys. The Army Research Laboratory (ARL tests showed that BAM-PPV combined with an epoxy primer and the Army chemical agent-resistant coating (CARC topcoat met Army performance requirements for military coatings. After successful laboratory testing, the BAM-PPV was then field tested for one year at the Aberdeen Test Center (ATC. This field testing showed that BAM-PPV incorporated into the Army military coating survived with no delamination of the coating and only minor corrosion on the chip sites.

  14. [Prognostic value of lacrimal duct diagnostics after tube removal : Retrospective analysis of risk of relapse during the first postoperative year after transcanalicular lacrimal duct surgery with silicone tubing].

    Science.gov (United States)

    Böhm, M; Heichel, J; Bredehorn-Mayr, T; Lautenschläger, C; Struck, H-G

    2017-05-01

    Transcanalicular lacrimal duct surgery has become more important over the past two decades. The aim of the study was to prove the prognostic value of postoperative lacrimal syringing and the testing of spontaneous drainage of lacrimal fluid immediately after tube removal. A total of 110 cases with postoperative lacrimal syringing and 183 cases with verification of the postoperative lacrimal fluid drainage performed between January 2001 and August 2008 were retrospectively evaluated. The indication for postoperative diagnostics was set by the investigator. The prognostic value of these two procedures was determined by using prognostic parameters (positive predictive value, PPV; negative predictive value, NPV) and analyzing recurrence nonexistence via Cox regression and Kaplan-Meier estimator. The observation period was limited to 12 months. Predominantly, recurrence was defined on the patient's satisfaction and absence of symptoms, which was determined with the help of a questionnaire. Postoperative verification of the lacrimal syringing is a suitable instrument to estimate surgical success within the first year after lacrimal surgery with a PPV of 92.31%. Testing of the spontaneous drainage of lacrimal fluid after tube removal reached a PPV of 63.33%. The proven prognostic value shows that syringing of the lacrimal duct and verification of spontaneous drainage should be integrated into postoperative care in a standardized manner. Hereby, early information for the patient about the expected result of the surgical procedure is enabled.

  15. Prognostic value of interferon-γ release assays, a population-based study from a TB low-incidence country

    DEFF Research Database (Denmark)

    Hermansen, Thomas Stig; Lillebaek, Troels; Langholz Kristensen, Kristina

    2016-01-01

    individuals and data on all TB cases in Denmark from 2005 to 2012 and determined the predictive value of the QFT for coprevalent TB (0-90 days after testing) and incident TB (>90 days). RESULTS: Coprevalent TB was diagnosed in 10.7% (183/1703) and 0.3% (38/13 463) cases with a positive and negative QFT......, respectively. For the QFT-positive cases, coprevalent TB was more frequent among persons 35  years (19.3% vs 7.2%, pvalues (PPV...

  16. The Value of High-Resolution MRI Technique in Patients with Rectal Carcinoma: Pre-Operative Assessment of Mesorectal Fascia Involvement, Circumferential Resection Margin and Local Staging

    International Nuclear Information System (INIS)

    Algebally, Ahmed Mohamed; Mohey, Nesreen; Szmigielski, Wojciech; Yousef, Reda Ramadan Hussein; Kohla, Samah

    2015-01-01

    The purpose of the study was to identify the accuracy of high-resolution MRI in the pre-operative assessment of mesorectal fascia involvement, circumfrential resection margin (CRM) and local staging in patients with rectal carcinoma. The study included 56 patients: 32 male and 24 female. All patients underwent high-resolution MRI and had confirmed histopathological diagnosis of rectal cancer located within 15 cm from the anal verge, followed by surgery. MRI findings were compared with pathological and surgical results. The overall accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MRI-based T-staging were 92.8, 88.8%, 96.5%, 96%, and 90.3%, respectively. The accuracy, sensitivity, specificity, PPV, and NPV of MRI-based assessment of CRM were 94.6%, 84.6%, 97.6%, 91.4, and 94.6%, respectively. The accuracy, sensitivity, specificity, PPV, and NPV of MRI-based N-staging were 82.1%, 75%, 67.3%, 60%, and 86.1%, respectively. Preoperative high-resolution rectal MRI is accurate in predicting tumor stage and CRM involvement. MRI is a precise diagnostic tool to select patients who may benefit from neo-adjuvant therapy and to avoid overtreatment in those patients who can proceed directly to surgery

  17. Phosphorene/rhenium disulfide heterojunction-based negative differential resistance device for multi-valued logic

    Science.gov (United States)

    Shim, Jaewoo; Oh, Seyong; Kang, Dong-Ho; Jo, Seo-Hyeon; Ali, Muhammad Hasnain; Choi, Woo-Young; Heo, Keun; Jeon, Jaeho; Lee, Sungjoo; Kim, Minwoo; Song, Young Jae; Park, Jin-Hong

    2016-01-01

    Recently, negative differential resistance devices have attracted considerable attention due to their folded current–voltage characteristic, which presents multiple threshold voltage values. Because of this remarkable property, studies associated with the negative differential resistance devices have been explored for realizing multi-valued logic applications. Here we demonstrate a negative differential resistance device based on a phosphorene/rhenium disulfide (BP/ReS2) heterojunction that is formed by type-III broken-gap band alignment, showing high peak-to-valley current ratio values of 4.2 and 6.9 at room temperature and 180 K, respectively. Also, the carrier transport mechanism of the BP/ReS2 negative differential resistance device is investigated in detail by analysing the tunnelling and diffusion currents at various temperatures with the proposed analytic negative differential resistance device model. Finally, we demonstrate a ternary inverter as a multi-valued logic application. This study of a two-dimensional material heterojunction is a step forward toward future multi-valued logic device research. PMID:27819264

  18. Phosphorene/rhenium disulfide heterojunction-based negative differential resistance device for multi-valued logic

    Science.gov (United States)

    Shim, Jaewoo; Oh, Seyong; Kang, Dong-Ho; Jo, Seo-Hyeon; Ali, Muhammad Hasnain; Choi, Woo-Young; Heo, Keun; Jeon, Jaeho; Lee, Sungjoo; Kim, Minwoo; Song, Young Jae; Park, Jin-Hong

    2016-11-01

    Recently, negative differential resistance devices have attracted considerable attention due to their folded current-voltage characteristic, which presents multiple threshold voltage values. Because of this remarkable property, studies associated with the negative differential resistance devices have been explored for realizing multi-valued logic applications. Here we demonstrate a negative differential resistance device based on a phosphorene/rhenium disulfide (BP/ReS2) heterojunction that is formed by type-III broken-gap band alignment, showing high peak-to-valley current ratio values of 4.2 and 6.9 at room temperature and 180 K, respectively. Also, the carrier transport mechanism of the BP/ReS2 negative differential resistance device is investigated in detail by analysing the tunnelling and diffusion currents at various temperatures with the proposed analytic negative differential resistance device model. Finally, we demonstrate a ternary inverter as a multi-valued logic application. This study of a two-dimensional material heterojunction is a step forward toward future multi-valued logic device research.

  19. Investigation on I-V for Different Heating Temperatures of Nanocomposited MEH-PPV:CNTs Organic Solar Cells

    Directory of Open Access Journals (Sweden)

    M. S. P. Sarah

    2012-01-01

    Full Text Available This paper discussed the effect of different thermal evaporation treatments for nanocomposited MEH-PPV:CNTs thin films towards the performance of organic solar cells. The configuration of the organic solar cells is ITO/MEH-PPV:CNTs/Au. The heating temperature was varied from, as deposited, 50°C, 75°C, and 100°C. From the results, we observed that the efficiency increase slightly before decreasing back at 100°C. The highest efficiency was solar cells heated at 75°C with efficiency 0.001% which is supported by the I-V characteristics and also by the absorption spectra.

  20. Annealing temperature effect on electrical properties of MEH-PPV thin film via spin coating method

    Science.gov (United States)

    Azhar, N. E. A.; Shariffudin, S. S.; Alrokayan, Salman A. H.; Khan, Haseeb A.; Rusop, M.

    2018-05-01

    Organic semiconductor has been discovered in different application devices such as organic light emitting diodes (OLEDs). Poly [2-methoxy-5(2' -ethylhexyloxy)-1, 4-phenylenevinylene), MEH-PPV widely used in this device because its ability to produce a good optical quality films. The MEH-PPV was prepared on glass substrate by spin coating method. The thin film was investigated at different annealing temperatures. The scanning electron micrographs (SEM) revealed that sample annealed at 50°C showed uniformity and less aggregation on morphology polymer thin film. Optical properties showed the intensities of visible emission increased as temperatures increased. The current-voltage (I-V) measurement revealed that the temperature of 50°C showed high conductive and it is suitable for optoelectronic device.

  1. FDG-PET Response Prediction in Pediatric Hodgkin’s Lymphoma: Impact of Metabolically Defined Tumor Volumes and Individualized SUV Measurements on the Positive Predictive Value

    Energy Technology Data Exchange (ETDEWEB)

    Hussien, Amr Elsayed M. [Department of Nuclear Medicine (KME), Forschungszentrum Jülich, Medical Faculty, Heinrich-Heine-University Düsseldorf, Jülich, 52426 (Germany); Department of Nuclear Medicine, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225 (Germany); Furth, Christian [Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University Magdeburg, Magdeburg, 39120 (Germany); Schönberger, Stefan [Department of Pediatric Oncology, Hematology and Clinical Immunology, University Children’s Hospital, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225 (Germany); Hundsdoerfer, Patrick [Department of Pediatric Oncology and Hematology, Charité Campus Virchow, Humboldt-University Berlin, Berlin, 13353 (Germany); Steffen, Ingo G.; Amthauer, Holger [Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University Magdeburg, Magdeburg, 39120 (Germany); Müller, Hans-Wilhelm; Hautzel, Hubertus, E-mail: h.hautzel@fz-juelich.de [Department of Nuclear Medicine (KME), Forschungszentrum Jülich, Medical Faculty, Heinrich-Heine-University Düsseldorf, Jülich, 52426 (Germany); Department of Nuclear Medicine, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225 (Germany)

    2015-01-28

    Background: In pediatric Hodgkin’s lymphoma (pHL) early response-to-therapy prediction is metabolically assessed by (18)F-FDG PET carrying an excellent negative predictive value (NPV) but an impaired positive predictive value (PPV). Aim of this study was to improve the PPV while keeping the optimal NPV. A comparison of different PET data analyses was performed applying individualized standardized uptake values (SUV), PET-derived metabolic tumor volume (MTV) and the product of both parameters, termed total lesion glycolysis (TLG); Methods: One-hundred-eight PET datasets (PET1, n = 54; PET2, n = 54) of 54 children were analysed by visual and semi-quantitative means. SUVmax, SUVmean, MTV and TLG were obtained the results of both PETs and the relative change from PET1 to PET2 (Δ in %) were compared for their capability of identifying responders and non-responders using receiver operating characteristics (ROC)-curves. In consideration of individual variations in noise and contrasts levels all parameters were additionally obtained after threshold correction to lean body mass and background; Results: All semi-quantitative SUV estimates obtained at PET2 were significantly superior to the visual PET2 analysis. However, ΔSUVmax revealed the best results (area under the curve, 0.92; p < 0.001; sensitivity 100%; specificity 85.4%; PPV 46.2%; NPV 100%; accuracy, 87.0%) but was not significantly superior to SUVmax-estimation at PET2 and ΔTLGmax. Likewise, the lean body mass and background individualization of the datasets did not impove the results of the ROC analyses; Conclusions: Sophisticated semi-quantitative PET measures in early response assessment of pHL patients do not perform significantly better than the previously proposed ΔSUVmax. All analytical strategies failed to improve the impaired PPV to a clinically acceptable level while preserving the excellent NPV.

  2. FDG-PET Response Prediction in Pediatric Hodgkin’s Lymphoma: Impact of Metabolically Defined Tumor Volumes and Individualized SUV Measurements on the Positive Predictive Value

    International Nuclear Information System (INIS)

    Hussien, Amr Elsayed M.; Furth, Christian; Schönberger, Stefan; Hundsdoerfer, Patrick; Steffen, Ingo G.; Amthauer, Holger; Müller, Hans-Wilhelm; Hautzel, Hubertus

    2015-01-01

    Background: In pediatric Hodgkin’s lymphoma (pHL) early response-to-therapy prediction is metabolically assessed by (18)F-FDG PET carrying an excellent negative predictive value (NPV) but an impaired positive predictive value (PPV). Aim of this study was to improve the PPV while keeping the optimal NPV. A comparison of different PET data analyses was performed applying individualized standardized uptake values (SUV), PET-derived metabolic tumor volume (MTV) and the product of both parameters, termed total lesion glycolysis (TLG); Methods: One-hundred-eight PET datasets (PET1, n = 54; PET2, n = 54) of 54 children were analysed by visual and semi-quantitative means. SUVmax, SUVmean, MTV and TLG were obtained the results of both PETs and the relative change from PET1 to PET2 (Δ in %) were compared for their capability of identifying responders and non-responders using receiver operating characteristics (ROC)-curves. In consideration of individual variations in noise and contrasts levels all parameters were additionally obtained after threshold correction to lean body mass and background; Results: All semi-quantitative SUV estimates obtained at PET2 were significantly superior to the visual PET2 analysis. However, ΔSUVmax revealed the best results (area under the curve, 0.92; p < 0.001; sensitivity 100%; specificity 85.4%; PPV 46.2%; NPV 100%; accuracy, 87.0%) but was not significantly superior to SUVmax-estimation at PET2 and ΔTLGmax. Likewise, the lean body mass and background individualization of the datasets did not impove the results of the ROC analyses; Conclusions: Sophisticated semi-quantitative PET measures in early response assessment of pHL patients do not perform significantly better than the previously proposed ΔSUVmax. All analytical strategies failed to improve the impaired PPV to a clinically acceptable level while preserving the excellent NPV

  3. Elimination of PPV and PNRSV through thermotherapy and meristem-tip culture in nectarine.

    Science.gov (United States)

    Manganaris, G A; Economou, A S; Boubourakas, I N; Katis, N I

    2003-10-01

    The plum pox virus (PPV) and prunus necrotic ringspot virus (PNRSV) cause serious disease problems in stone-fruit trees. In this work, the possibility of obtaining plant material free from these viruses through thermotherapy and meristem-tip culture from infected nectarine shoots (Prunus persica var. nectarina Max, cv. 'Arm King') was studied. In addition, the detection of these viruses in in vitro cultures and young acclimatized plantlets with double antibody sandwich-enzyme-linked immunosorbent assay (DAS-ELISA) and multiplex reverse transcriptase-polymerase chain reaction (RT-PCR) was studied. Meristem-tip explants (0.8-1.3 mm) derived from sprouted buds of winter wood and spring shoots from field grown plants had a 2-5% regeneration response. However, application of thermotherapy to potted nectarine trees (3 weeks at a maximum temperature of 35 degrees C) facilitated excision of longer meristem tips (1.3-2.0 mm) that resulted in a significantly higher regeneration response (38%) in woody plant medium (WPM) without plant growth regulators. Such explants formed multiple shoots with the addition of 8 microM benzylaminopurine and 0.8 microM indoleacetic acid. When they were tested for the presence of PPV and PNRSV, 86% and 81% were found to be virus-free as detected by DAS-ELISA and multiplex RT-PCR, respectively. Individual shoots excised from virus-free cultures readily rooted in vitro (half-strength WPM plus 2 microM indolebutyric acid) and grew to plantlets. The combination of an efficient protocol for virus elimination and the establishment of highly sensitive diagnostics resulted in the production of nectarine plants free from PPV and PNRSV.

  4. The Value of a Checklist for Child Abuse in Out-of-Hours Primary Care: To Screen or Not to Screen.

    Directory of Open Access Journals (Sweden)

    Maartje Cm Schouten

    Full Text Available To assess the diagnostic value of the screening instrument SPUTOVAMO-R2 (checklist, 5 questions for child abuse at Out-of-hours Primary Care locations (OPC, by comparing the test outcome with information from Child Protection Services (CPS. Secondary, to determine whether reducing the length of the checklist compromises diagnostic value.All children (<18 years attending one of the participating OPCs in the region of Utrecht, the Netherlands, in a year time, were included. The checklist is an obligatory field in the electronic patient file. CPS provided data on all checklist positives and a sample of 5500 checklist negatives (dataset. The checklist outcome was compared with a report to CPS in 10 months follow up after the OPC visit.The checklist was filled in for 50671 children; 108 (0.2% checklists were positive. Within the dataset, 61 children were reported to CPS, with emotional neglect as the most frequent type of abuse (32.8%. The positive predictive value (PPV of the checklist for child abuse was 8.3 (95% CI 3.9-15.2. The negative predictive value (NPV was 99.1 (98.8-99.3, with 52 false negatives. When the length of the checklist was reduced to two questions closely related to the medical process (SPUTOVAMO-R3, the PPV was 9.1 (3.7-17.8 and the NPV 99.1 (98.7-99.3. These two questions are on the injury in relation to the history, and the interaction between child and parents.The checklist SPUTOVAMO-R2 has a low detection rate of child abuse within the OPC setting, and a high false positive rate. Therefore, we recommend to use the shortened checklist only as a tool to increase the awareness of child abuse and not as a diagnostic instrument.

  5. Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-non invasive multicenter Italian study for coronary artery disease)

    International Nuclear Information System (INIS)

    Marano, Riccardo; Cobelli, Francesco de; Maschio, Alessandro del; Becker, Christoph; Herzog, Christopher; Centonze, Maurizio; Morana, Giovanni; Gualdi, Gian Franco; Ligabue, Guido; Pontone, Gianluca; Catalano, Carlo; Chiappino, Dante; Midiri, Massimo; Simonetti, Giovanni; Marchisio, Filippo; Olivetti, Lucio; Fattori, Rossella; Bonomo, Lorenzo

    2009-01-01

    This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (≥16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines. (orig.)

  6. Fluorescence blinking in MEH-PPV single molecules at low temperature

    International Nuclear Information System (INIS)

    Mirzov, O.; Cichos, F.; Borczyskowski, C. von; Scheblykin, I.

    2005-01-01

    Fluorescence intensity transients of single molecules of the conjugated polymer poly[2-methoxy,5-(2'-ethylhexyloxy)-p-phenylene-vinylene] (MEH-PPV) were studied at 15 K. Fluorescence blinking behavior was observed despite the expected low-temperature suppression of energy migration in such disordered molecular systems. Presence of the fluorescence blinking effect at 15 K indicates that the single molecules possess a collapsed conformation with characteristic size of not more than several nanometers, which corresponds to only a few exciton hops over a polymer chain

  7. Most negative and most positive expectation values of the spin operator

    International Nuclear Information System (INIS)

    Zamick, Larry

    2011-01-01

    Formulas for the most positive and most negative values of the expectation of the spin operator are given and compared with single-particle values. The Nilsson model is used to evaluate these expectations and a scenario is discussed where the value is greater than one.

  8. Profluorescent PPV-Based Micellar System as a Versatile Probe for Bioimaging and Drug Delivery.

    Science.gov (United States)

    Zaquen, Neomy; Lu, Hongxu; Chang, Teddy; Mamdooh, Russel; Lutsen, Laurence; Vanderzande, Dirk; Stenzel, Martina; Junkers, Thomas

    2016-12-12

    Although micelles are commonly used for drug delivery purposes, their long-term fate is often unknown due to photobleaching of the fluorescent labels or the use of toxic materials. Here, we present a metal-free, nontoxic, nonbleaching, fluorescent micelle that can address these shortcomings. A simple, yet versatile, profluorescent micellar system, built from amphiphilic poly(p-phenylenevinylene) (PPV) block copolymers, for use in drug delivery applications is introduced. Polymer micelles made from PPV show excellent stability for up to 1 year and are successfully loaded with anticancer drugs (curcumin or doxorubicin) without requiring introduction of physical or chemical cross-links. The micelles are taken up efficiently by the cells, which triggers disassembly, releasing the encapsulated material. Disassembly of the micelles and drug release is conveniently monitored as fluorescence of the single polymer chains appear, which enables not only to monitor the release of the payload, but in principle also the fate of the polymer over longer periods of time.

  9. A large interconnecting network within hybrid MEH-PPV/TiO2 nanorod photovoltaic devices

    International Nuclear Information System (INIS)

    Zeng, T-W; Lin, Y-Y; Lo, H-H; Chen, C-W; Chen, C-H; Liou, S-C; Huang, H-Y; Su, W-F

    2006-01-01

    This is a study of hybrid photovoltaic devices based on TiO 2 nanorods and poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV). We use TiO 2 nanorods as the electron acceptors and conduction pathways. Here we describe how to develop a large interconnecting network within the photovoltaic device fabricated by inserting a layer of TiO 2 nanorods between the MEH-PPV:TiO 2 nanorod hybrid active layer and the aluminium electrode. The formation of a large interconnecting network provides better connectivity to the electrode, leading to a 2.5-fold improvement in external quantum efficiency as compared to the reference device without the TiO 2 nanorod layer. A power conversion efficiency of 2.2% under illumination at 565 nm and a maximum external quantum efficiency of 24% at 430 nm are achieved. A power conversion efficiency of 0.49% is obtained under Air Mass 1.5 illumination

  10. Phytohormone Signaling of the Resistance to Plum pox virus (PPV, Sharka Disease) Induced by Almond (Prunus dulcis (Miller) Webb) Grafting to Peach (P. persica L. Batsch)

    OpenAIRE

    Azam Nikbakht Dehkordi; Manuel Rubio; Nadali Babaeian; Alfonso Albacete; Pedro Martínez-Gómez

    2018-01-01

    Plum pox virus (PPV, sharka) is a limiting factor for peach production, and no natural sources of resistance have been described. Recent studies, however, have demonstrated that grafting the almond cultivar “Garrigues” onto the “GF305” peach infected with Dideron-type (PPV-D) isolates progressively reduces disease symptoms and virus accumulation. Furthermore, grafting “Garrigues” onto “GF305” prior to PPV-D inoculation has been found to completely prevent virus infection, showing that resista...

  11. Clinical Usefulness of F-18 FDG PET/CT in papillary thyroid cancer with negative radioiodine scan and elevated thyroglobulin level or positive anti-thyroglobulin antibody

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Su Jung; Jung, Kyung Pyo; Lee, Sun Seong; Park, Yun Soo; Lee, Seok Mo [Dept. of Nuclear Medicine, Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of); Bae, Sang Kyun [Dept. of Nuclear Medicine, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2016-06-15

    Elevated thyroglobulin (Tg) levels, along with a negative radioiodine scan, present a clinical problem for the diagnosis of recurrence in papillary thyroid cancer (PTC) patients. The purpose of this study was to assess (1) the usefulness of 18F-fluorodeoxyglucose (F-18 FDG) positron emission tomography (PET)/computed tomography (CT) for PTC patients with negative diagnostic radioiodine scan and elevated serum Tg level or positive anti-thyroglobulin antibody (TgAb), and (2) the effect of endogenous thyroid stimulating hormone (TSH) stimulation (ETS) on detecting recurrence in these circumstances. Eighty-four patients with negative diagnostic radioiodine scan and elevated serum Tg or positive TgAb under ETS were included. Correlation with clinicopathological features and recurrence, detectability of FDG PET/CT and cut-off value of serum Tg for recurrence in PTC patients with these circumstance were assessed. In addition, detectability of F-18 FDG PET/CT under ETS and suppression were compared. In Cox regression analysis, only serum Tg level was significantly associated with recurrence (P<0.001, HR  = 1.13; 95 % CI, 1.061–1.208). The cut-off level of Tg was 21.5 ng/mL (AUC, 0.919; P < 0.001) for discriminating the recurrence in the patients with positive PET/CT finding. The sensitivity, specificity, PPV, NPV, and accuracy of F-18 FDG PET/CT for detecting recurrence were 64 %, 94 %, 86 %, 81 %, and 83 %. In the analysis of F-18 FDG PET/CT under ETS, the sensitivity, specificity, PPV, NPV and accuracy was 64 %, 94 %, 88 %, 81 % and 83 %. Those under TSH suppression were 67 %, 92 %, 80 %, 85 % and 83 %. F-18 FDG PET/CT, although less sensitive, showed high specificity, PPV, NPV, and accuracy and therefore can be useful for the patients with negative diagnostic radioiodine scan and elevated serum Tg or positive TgAb. In addition, FDG PET/CT under ETS does not seem to have an additive role in detecting recurrence in these patients.

  12. Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection

    Energy Technology Data Exchange (ETDEWEB)

    Borens, Bruno [Polyclinique Santa Maria, Nice (France); Arvanitakis, Marianna; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques [Erasme Hospital, Department of Gastroenterology, Brussels (Belgium); Absil, Julie; Matos, Celso; Bali, Maria Antonietta [Erasme Hospital, Department of Radiology, Brussels (Belgium); El Bouchaibi, Said [Epicura, Ath (Belgium)

    2017-03-15

    To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC). Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm{sup 2}) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance. For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P >.05). ADC were lower in infected versus non-infected PFCs (P ≤.031). Minimum ADC cut-off: 1,090 x 10{sup -3} mm{sup 2}/s for reader 1 and 1,012 x 10{sup -3} mm{sup 2}/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers). Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. (orig.)

  13. Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection

    International Nuclear Information System (INIS)

    Borens, Bruno; Arvanitakis, Marianna; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques; Absil, Julie; Matos, Celso; Bali, Maria Antonietta; El Bouchaibi, Said

    2017-01-01

    To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC). Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm"2) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance. For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P >.05). ADC were lower in infected versus non-infected PFCs (P ≤.031). Minimum ADC cut-off: 1,090 x 10"-"3 mm"2/s for reader 1 and 1,012 x 10"-"3 mm"2/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers). Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. (orig.)

  14. Controlling morphology and chain aggregation in semiconducting conjugated polymers: the role of solvent on optical gain in MEH-PPV.

    Science.gov (United States)

    Lampert, Zach E; Reynolds, C Lewis; Papanikolas, John M; Aboelfotoh, M Osama

    2012-10-25

    We report the results of a detailed investigation that addresses the influence of polymer morphology and chain aggregation, as controlled by the chemical nature of the solvent, on the optical gain properties of the conjugated polymer poly[2-methoxy-5-(2'-ethylhexyloxy)-p-phenylene vinylene] (MEH-PPV). Using the variable stripe length technique in the picosecond regime, we have extensively studied the optical gain performance of asymmetric planar waveguides formed with thin MEH-PPV films spin-cast from concentrated chlorobenzene (CB) and tetrahydrofuran (THF) solutions onto thermally oxidized silicon substrates. CB and THF solvents were chosen based on their known ability to promote and effectively limit aggregate formation, respectively. Very large net gain coefficients are demonstrated, reaching values of 330 and 365 cm(-1), respectively, when optically pumping the waveguides with a maximum energy density of 85 μJ/cm(2). Our results clearly demonstrate that polymer morphology, and hence, the chain conformation dependence of the degree of aggregation in the films as controlled by the solvent, has minimal impact on the net gain. Moreover, the waveguides exhibit low loss coefficients of 10-20 cm(-1) at the ASE wavelength. These results question the importance of polymer morphology and aggregate formation in polymer-based optical devices operating at high excitation densities in the stimulated emission regime as would be characteristic of lasers and optical amplifiers.

  15. Phytohormone Signaling of the Resistance to Plum pox virus (PPV, Sharka Disease) Induced by Almond (Prunus dulcis (Miller) Webb) Grafting to Peach (P. persica L. Batsch).

    Science.gov (United States)

    Dehkordi, Azam Nikbakht; Rubio, Manuel; Babaeian, Nadali; Albacete, Alfonso; Martínez-Gómez, Pedro

    2018-05-03

    Plum pox virus (PPV, sharka) is a limiting factor for peach production, and no natural sources of resistance have been described. Recent studies, however, have demonstrated that grafting the almond cultivar "Garrigues" onto the "GF305" peach infected with Dideron-type (PPV-D) isolates progressively reduces disease symptoms and virus accumulation. Furthermore, grafting "Garrigues" onto "GF305" prior to PPV-D inoculation has been found to completely prevent virus infection, showing that resistance is constitutive and not induced by the virus. To unravel the phytohormone signaling of this mechanism, we analyzed the following phytohormones belonging to the principal hormone classes: the growth-related phytohormones cytokinin trans-zeatin (tZ) and the gibberellins GA₃ and GA₄; and the stress-related phytohormones ethylene acid precursor 1-aminocyclopropane-1-carboxylic acid (ACC), abscisic acid (ABA), salicylic acid (SA), and jasmonic acid (JA). PPV inoculation produced a significant increase in GA₃ and ABA in peach, and these imbalances were related to the presence of chlorosis symptoms. However, grafting "Garrigues" almond onto the PPV-inoculated "GF305" peach produced the opposite effect, reducing GA₃ and ABA contents in parallel to the elimination of symptoms. Our results showed the significant implication of SA in this induced resistance in peach with an additional effect on tZ and JA concentrations. This SA-induced resistance based in the decrease in symptoms seems to be different from Systemic Acquired Resistance (SAR) and Induced Systemic Resistance (ISR), which are based in other reactions producing necrosis. Further studies are necessary, however, to validate these results against PPV-D isolates in the more aggressive Marcus-type (PPV-M) isolates.

  16. Diagnostic value of pelvic enthesitis on MRI of the sacroiliac joints in spondyloarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Jans, L.; Langenhove, C. van; Lambrecht, V.; Verstraete, K. [Ghent University Hospital, Department of Radiology and Medical Imaging, Gent (Belgium); Praet, L. van; Carron, P.; Elewaut, D.; Bosch, F.V. den [Ghent University Hospital, Department of Rheumatology, Gent (Belgium); Jaremko, J.L. [University of Alberta Hospital, Department of Radiology, Edmonton, Alberta (Canada)

    2014-04-15

    To determine the prevalence and diagnostic value of pelvic enthesitis on MRI of the sacroiliac (SI) joints in spondyloarthritis (SpA). A retrospective study in 444 patients aged 17-45 years old with MRI of the SI joints and with clinically suspected sacroiliitis was performed. Patients were classified as having SpA if they fulfilled the Assessment of Spondyloarthritis International Society (ASAS) criteria. Pelvic enthesitis on MRI was correlated with the final diagnosis. Sensitivity, specificity, positive and negative likelihood ratio (LR) and predictive values (PV) of pelvic enthesitis for the diagnosis of SpA were calculated. MRI showed pelvic enthesitis in 24.4 % of patients with SpA and in 7.1 % of patients without SpA. Presence of any enthesitis had sensitivity, specificity, LR+, LR-, PPV and NPV of 24.4 %, 92.9 %, 3.45, 0.81, 69.4 % and 65.2 % for the diagnosis of SpA, respectively. The most commonly affected entheses were the longitudinal ligament insertion (4.5 %), the retroarticular ligaments (4.1 %) and the pubic symphysis (4.1 %). The sites of enthesitis with the highest PPV for SpA were the iliac crest/wing (85.7 %) and the retroarticular ligaments (81.3 %). Nearly one fourth of SpA patients with suspected sacroiliitis showed pelvic enthesitis on MRI. Such pelvic enthesitis has a high specificity for the diagnosis of spondyloarthritis. (orig.)

  17. Relation between exciplex formation and photovoltaic properties of PPV polymer-based blends

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Chunhong; Neher, Dieter [Institute of Physics, University of Potsdam, Am Neuen Palais 10, 14469 Potsdam (Germany); Kietzke, Thomas [Institute of Physics, University of Potsdam, Am Neuen Palais 10, 14469 Potsdam (Germany); Institute of Materials Research and Engineering (IMRE), Research Link 3, 117602 Singapore (Singapore); Kumke, Michael [Institute of Chemistry, University of Potsdam, Karl-Liebknecht-Street 24-25, 14476 Golm (Germany); Hoerhold, Hans-Heinrich [Institute of Organic Chemistry and Macromolecular Chemistry, University of Jena, Humboldtstr. 10, 07743 Jena (Germany)

    2007-03-06

    As a new record for pure polymer-blend solar cells, an energy conversion efficiency (ECE) of 1.7% was recently achieved for M3EH-PPV:CN-ether-PPV (Poly[oxa-1,4-phenylene-1,2-(1-cyano)-ethylene-2,5-dioctyloxy-1,4-phenylene-1,2- (2-cyano)-ethylene-1,4-phenylene]) based devices [T. Kietzke, H.-H. Hoerhold, D. Neher, Chem. Mater. 17 (2005) 6532]. Even though that photoluminescence experiments indicated that 95% of the photogenerated excitions were dissociated in the blend, the external quantum efficiency reached only 31%. Thus more than 2/3 of the dissociated excitons were lost for the energy conversion. In order to identify the processes which limit the photovoltaic efficiency of polymer-blend solar cells, studies on the steady state and time-resolved photoluminescence of the individual polymer and polymer blend were performed. In the polymer-blend layer, we observed a considerable long-wavelength emission due to exciplex formation. The exciplex emission can be reduced by thermal annealing. At the same time the IPCE of the blend-based device increased, indicating a more efficient generation of free-charge carriers. These findings lead to the conclusion that charge-carrier recombination via exciplex formation constitutes one of the loss channels which limits the efficiency of polymer solar cells. (author)

  18. Diagnostic accuracy of an MRI protocol of the knee accelerated through parallel imaging in correlation to arthroscopy

    International Nuclear Information System (INIS)

    Schnaiter, Johannes Walter; McKenna-Kuettner, Axel; Roemer, Frank; May, Matthias Stefan; Janka, Rolf; Uder, Michael; Wuest, Wolfgang; Patzak, Hans-Joachim

    2018-01-01

    Parallel imaging allows for a considerable shortening of examination times. Limited data is available about the diagnostic accuracy of an accelerated knee MRI protocol based on parallel imaging evaluating all knee joint compartments in a large patient population compared to arthroscopy. 162 consecutive patients with a knee MRI (1.5 T, Siemens Aera) and arthroscopy were included. The total MRI scan time was less than 9 minutes. Meniscus and cartilage injuries, cruciate ligament lesions, loose joint bodies and medial patellar plicae were evaluated. Sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV), as well as diagnostic accuracy were determined. For the medial meniscus, the values were: SE 97 %, SP 88 %, PPV 94 %, and NPV 94 %. For the lateral meniscus the values were: SE 77 %, SP 99 %, PPV 98 %, and NPV 89 %. For cartilage injuries the values were: SE 72 %, SP 80 %, PPV 86 %, and NPV 61 %. For the anterior cruciate ligament the values were: SE 90 %, SP 94 %, PPV 77 %, and NPV 98 %, while all values were 100 % for the posterior cruciate ligament. For loose bodies the values were: SE 48 %, SP 96 %, PPV 62 %, and NPV 93 %, and for the medial patellar plicae the values were: SE 57 %, SP 88 %, PPV 18 %, and NPV 98 %. A knee MRI examination with parallel imaging and a scan time of less than 9 minutes delivers reliable results with high diagnostic accuracy.

  19. Phytohormone Signaling of the Resistance to Plum pox virus (PPV, Sharka Disease Induced by Almond (Prunus dulcis (Miller Webb Grafting to Peach (P. persica L. Batsch

    Directory of Open Access Journals (Sweden)

    Azam Nikbakht Dehkordi

    2018-05-01

    Full Text Available Plum pox virus (PPV, sharka is a limiting factor for peach production, and no natural sources of resistance have been described. Recent studies, however, have demonstrated that grafting the almond cultivar “Garrigues” onto the “GF305” peach infected with Dideron-type (PPV-D isolates progressively reduces disease symptoms and virus accumulation. Furthermore, grafting “Garrigues” onto “GF305” prior to PPV-D inoculation has been found to completely prevent virus infection, showing that resistance is constitutive and not induced by the virus. To unravel the phytohormone signaling of this mechanism, we analyzed the following phytohormones belonging to the principal hormone classes: the growth-related phytohormones cytokinin trans-zeatin (tZ and the gibberellins GA3 and GA4; and the stress-related phytohormones ethylene acid precursor 1-aminocyclopropane-1-carboxylic acid (ACC, abscisic acid (ABA, salicylic acid (SA, and jasmonic acid (JA. PPV inoculation produced a significant increase in GA3 and ABA in peach, and these imbalances were related to the presence of chlorosis symptoms. However, grafting “Garrigues” almond onto the PPV-inoculated “GF305” peach produced the opposite effect, reducing GA3 and ABA contents in parallel to the elimination of symptoms. Our results showed the significant implication of SA in this induced resistance in peach with an additional effect on tZ and JA concentrations. This SA-induced resistance based in the decrease in symptoms seems to be different from Systemic Acquired Resistance (SAR and Induced Systemic Resistance (ISR, which are based in other reactions producing necrosis. Further studies are necessary, however, to validate these results against PPV-D isolates in the more aggressive Marcus-type (PPV-M isolates.

  20. Photoelectrochemical properties of ZnO nanocrystals/MEH-PPV composite: The effects of nanocrystals synthetic route, film deposition and electrolyte composition

    Energy Technology Data Exchange (ETDEWEB)

    Petrella, A. [Dipartimento di Ingegneria Civile, Ambientale, del Territorio, Edile e Chimica, Politecnico di Bari, Via Orabona 4, 70125 Bari (Italy); Curri, M.L.; Striccoli, M. [CNR IPCF Sez. Bari c/o Dip. Chimica, Università di Bari, Via Orabona 4, 70126 Bari (Italy); Agostiano, A. [Dipartimento di Chimica, Università di Bari, via Orabona 4, 70126 Bari (Italy); CNR IPCF Sez. Bari c/o Dip. Chimica, Università di Bari, Via Orabona 4, 70126 Bari (Italy); Cosma, P., E-mail: pinalysa.cosma@uniba.it [Dipartimento di Chimica, Università di Bari, via Orabona 4, 70126 Bari (Italy); CNR IPCF Sez. Bari c/o Dip. Chimica, Università di Bari, Via Orabona 4, 70126 Bari (Italy)

    2015-11-30

    This paper reports a study on the photoelectrochemical processes occurring at the interface of ZnO nanocrystals/MEH-PPV composites. Colloidal chemical routes were used to obtain size controlled non-hydrolytic ZnO nanocrystals (NCs) dispersible in organic solvents, while a low molecular weight poly[2-methoxy-5-(2′-ethyl-hexyloxy)phenylene vinylene] (MEH-PPV), characterized by high degree of structural order, was synthesized via an organometallic method. The optical properties of the nanocomposite material were comprehensively investigated on solution and on films deposited by spin coating. Remarkably, a significant fluorescence quenching of the polymer at the MEH-PPV/ZnO junction was observed. Photoelectrochemical measurements demonstrated that the photoactivity of the composite material was significantly improved in the case of non-hydrolytic NCs with respect to hydrolytic route prepared ZnO. Moreover, the effective role of the organic/inorganic blend to improve the charge transfer with respect to the double layer hetero-junction was confirmed, thanks to the extended interfaces which enable an effective electron transfer between the hetero-junction components. The system was also studied at different film thicknesses and electrolyte compositions. The results indicated that film photoactivity increased with film thickness up to 300 nm due to the presence of a large number of interfaces, while the change of cation size influenced the ionic conductivity through the nanocomposite film. It was shown that efficient photoconductivity requires not only efficient charge separation, but also efficient transport of the carriers to the electrodes without recombination. - Highlights: • The photoelectrochemical processes at ZnO nanocrystals/MEH-PPV hetero-junction were studied. • Fluorescence quenching of the polymer at the MEH-PPV/ZnO interface was observed. • Non-hydrolytic ZnO junction showed higher photocurrents than hydrolytic equivalent. • The blends showed

  1. Photoelectrochemical properties of ZnO nanocrystals/MEH-PPV composite: The effects of nanocrystals synthetic route, film deposition and electrolyte composition

    International Nuclear Information System (INIS)

    Petrella, A.; Curri, M.L.; Striccoli, M.; Agostiano, A.; Cosma, P.

    2015-01-01

    This paper reports a study on the photoelectrochemical processes occurring at the interface of ZnO nanocrystals/MEH-PPV composites. Colloidal chemical routes were used to obtain size controlled non-hydrolytic ZnO nanocrystals (NCs) dispersible in organic solvents, while a low molecular weight poly[2-methoxy-5-(2′-ethyl-hexyloxy)phenylene vinylene] (MEH-PPV), characterized by high degree of structural order, was synthesized via an organometallic method. The optical properties of the nanocomposite material were comprehensively investigated on solution and on films deposited by spin coating. Remarkably, a significant fluorescence quenching of the polymer at the MEH-PPV/ZnO junction was observed. Photoelectrochemical measurements demonstrated that the photoactivity of the composite material was significantly improved in the case of non-hydrolytic NCs with respect to hydrolytic route prepared ZnO. Moreover, the effective role of the organic/inorganic blend to improve the charge transfer with respect to the double layer hetero-junction was confirmed, thanks to the extended interfaces which enable an effective electron transfer between the hetero-junction components. The system was also studied at different film thicknesses and electrolyte compositions. The results indicated that film photoactivity increased with film thickness up to 300 nm due to the presence of a large number of interfaces, while the change of cation size influenced the ionic conductivity through the nanocomposite film. It was shown that efficient photoconductivity requires not only efficient charge separation, but also efficient transport of the carriers to the electrodes without recombination. - Highlights: • The photoelectrochemical processes at ZnO nanocrystals/MEH-PPV hetero-junction were studied. • Fluorescence quenching of the polymer at the MEH-PPV/ZnO interface was observed. • Non-hydrolytic ZnO junction showed higher photocurrents than hydrolytic equivalent. • The blends showed

  2. Increased luminance of MEH-PPV and PFO based PLEDs by using salmon DNA as an electron blocking layer

    International Nuclear Information System (INIS)

    Madhwal, Devinder; Rait, S.S.; Verma, A.; Kumar, Amit; Bhatnagar, P.K.; Mathur, P.C.; Onoda, M.

    2010-01-01

    The effect of salmon DNA-CTMA as an electron blocking layer (EBL) has been examined on the performance of MEH-PPV and PFO-based light emitting diodes. Though the turn-on voltage increases with incorporation of EBL, a significant increase in luminance and luminous efficiency for both the devices is observed. The EBL improves the device performance by blocking electrons at the EBL-polymer interface, thereby increasing the recombination probability of electrons and holes. The luminance of the MEH-PPV based Bio-LED increases to 100 cd/m 2 from 30 cd/m 2 while a corresponding increase for the PFO based LED is to 160 cd/m 2 from 80 cd/m 2 with and without EBL, respectively.

  3. Anionic PPV polymerization from the sulfinyl precursor route : Block copolymer formation from sequential addition of monomers

    NARCIS (Netherlands)

    Cosemans, Inge; Vandenbergh, Joke; Voet, Vincent S. D.; Loos, Katja; Lutsen, Laurence; Vanderzande, Dirk; Junkers, Thomas

    2013-01-01

    The sulfinyl precursor route for the synthesis of poly(p-phenylene vinylene) (PPV) materials via an anionic polymerization procedure employing dedicated initiators is evaluated in depth. Reaction kinetics are investigated to gain more control over the polymerization, since polymerization proceeds to

  4. Electrical characterization of MEH-PPV based Schottky diodes

    Energy Technology Data Exchange (ETDEWEB)

    Nimith, K. M., E-mail: nimithkm@gmail.com; Satyanarayan, M. N., E-mail: satya-mn@nitk.edu.in; Umesh, G., E-mail: umesh52@gmail.com [Optoelectronics Laboratory (OEL), Department of Physics, National Institute of Technology Karnataka (NITK),Surathkal, PO Srinivasnagar, Mangalore, DK-575025 (India)

    2016-05-06

    MEH-PPV Schottky diodes with and without Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT-PSS) have been fabricated and characterized. The highlight of this work is that all the fabrication and characterization steps had been carried out in the ambient conditions and the device fabrication was done without any UV-Ozone surface treatment of ITO anodes. Current Density-Voltage characteristics shows that the addition of hole injection layer (HIL) enhances the charge injection into the polymer layer by reducing the energy barrier across the Indium Tin Oxide (ITO)-Organic interface. The rectification ratio increases to 2.21 from 0.76 at 5V for multilayer devices compared to single layer devices. Further we investigated the effect of an alkali metal fluoride (LiF) by inserting a thin layer in between the organic layer and Aluminum (Al) cathode. The results of these investigations will be discussed in detail.

  5. Predictive value of brain SPECT with 99 technetium - MIBI for differentiation of histologic grade brain gliomas

    International Nuclear Information System (INIS)

    León Castellón, Roberto; Martín Escuela, Juan Miguel; López Díaz, Ing. Adlin; Salva Camaño, Silvia; Gómez Viera, DrC. Nelson; San Pedro, Aley Palau; Castro Jiménez, Mayté

    2016-01-01

    Diagnosis and treatment of primary tumors of the nervous system remain difficult and are a challenge to be addressed in a multidisciplinary way. In order to determine the usefulness of brain SPECT 99 Tc MIBI to differentiate histologic grade brain gliomas - Frequently brain tumors - they were studied 68 patients with this technique. A dynamic study first step in AP and lateral view was performed, and a SPECT at 20 minutes post-administration and at 2 hours late views. the post-surgical histological study of injuries was used as control. several imaging parameters such as the absolute activity of 99m Tc-MIBI were calculated both early and late phase, cortex contralateral tumor rates; pituitary tumor; choroid plexus tumor and Reason Late / Early phase tumor index / contralateral cortex tumor volume functional phase, the volume concentration of MIBI activity in the tumor and the retention rate of the radiopharmaceutical. Of the 68 patients studied, 11 were high-grade tumors and 57 low grade. The cortex contralateral tumor in late stage index showed a negative satisfactory sensitivity of 98.6% and specificity 77.1%, positive predictive value (PPV) of 48.2% and (NPV) of 99.8%. The reason late stage / early in the index tumor / contralateral cortex showed values ​​in turn 96.3%, 98.7%, 98.8% and 98.8% sensitivity, specificity, PPV and NPV respectively. The retention rate showed a 99% sensitivity, 89% specificity and PPV, NPV of 95% and 99% respectively. Conclusion: The combination cortex contralateral tumor rate in late stage, the reason late stage / early stage tumor index / contralateral cortex and the retention rate of the radiopharmaceutical are the most useful parameters to predict histologic grade of brain gliomas. (author)

  6. An improved value for the electron affinity of the negative hydrogen ion

    International Nuclear Information System (INIS)

    Scherk, L.R.

    1979-01-01

    An expression is derived for the lifetime of a negative ion in a weak and static electric field. Using this expression, existing experimental data are analyzed to improve the empirical value of the electron affinity of the negative hydrogen ion by an order of magnitude. (author)

  7. CT colonography without cathartic preparation: positive predictive value and patient experience in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Zueco Zueco, Carmen; Sobrido Sampedro, Carolina; Corroto, Juan D.; Rodriguez Fernandez, Paula; Fontanillo Fontanillo, Manuela [Complexo Hospitalario Universitario de Vigo - CHUVI, Vigo, Pontevedra (Spain)

    2012-06-15

    To determine the positive predictive value (PPV) for polyps {>=}6 mm detected at CT colonography (CTC) performed without cathartic preparation, with low-dose iodine faecal tagging regimen and to evaluate patient experience. 1920 average-risk patients underwent CTC without cathartic preparation. Faecal tagging was performed by diatrizoate meglumine and diatrizoate sodium at a total dose of 60 ml (22.2 g of iodine).The standard interpretation method was primary 3D with 2D problem solving. We calculated per-patient and per-polyp PPV in relation to size and morphology. All colonic segments were evaluated for image quality (faecal tagging, amount of liquid and solid residual faeces and luminal distension). Patients completed a questionnaire before and after CTC to assess preparation and examination experience. Per-polyp PPV for detected lesions of {>=}6 mm, 6-9 mm, {>=}10 mm and {>=}30 mm were 94.3%, 93.1%, 94.7% and 98%, respectively. Per-polyp PPV, according to lesion morphology, was 94.6%, 97.3% and 85.1% for sessile, pedunculated and flat polyps, respectively. Per-patient PPV was 92.8%. Preparation without frank cathartics was reported to cause minimal discomfort by 78.9% of patients. CTC without cathartic preparation and low-dose iodine faecal tagging may yield high PPVs for lesions {>=}6 mm and is well accepted by patients. circle Computed tomographic colonography (CTC) without cathartic preparation is well accepted by patients circle Cathartic-free faecal tagging CTC yields high positive predictive values circle CTC without cathartic preparation could improve uptake of colorectal cancer screening. (orig.)

  8. Predictive values of BI-RADS® magnetic resonance imaging (MRI) in the detection of breast ductal carcinoma in situ (DCIS)

    International Nuclear Information System (INIS)

    Badan, Gustavo Machado; Piato, Sebastião; Roveda, Décio; Faria Castro Fleury, Eduardo de

    2016-01-01

    Purpose: The purpose of this study was to evaluate BI-RADS indicators in the detection of DCIS by MRI. Materials and methods: Prospective observational study that started in 2014 and lasted 24 months. A total of 110 consecutive patients were evaluated, who presented with suspicious or highly suspicious microcalcifications on screening mammography (BI-RADS categories 4 and 5) and underwent stereotactic-guided breast biopsy, having had an MRI scan performed prior to biopsy. Results: Altogether, 38 cases were characterized as positive for malignancy, of which 25 were DCIS and 13 were invasive ductal carcinoma cases. MRI had a sensitivity of 96%; specificity of 75.67%; positive predictive value (PPV) for DCIS detection of 57.14%; negative predictive value (NPV) in the detection of DCIS of 98.24%; and an accuracy of 80.80%. Conclusion: BI-RADS as a tool for the detection of DCIS by MRI is a powerful instrument whose sensitivity was higher when compared to that observed for mammography in the literature. Likewise, the PPV obtained by MRI was higher than that observed in the present study for mammography, and the high NPV obtained on MRI scans can provide early evidence to discourage breast biopsy in selected cases.

  9. Praise for regret: People value regret above other negative emotions.

    Science.gov (United States)

    Saffrey, Colleen; Summerville, Amy; Roese, Neal J

    2008-03-01

    What do people think about the emotion of regret? Recent demonstrations of the psychological benefits of regret have been framed against an assumption that most people find regret to be aversive, both when experienced but also when recalled later. Two studies explored lay evaluations of regret experiences, revealing them to be largely favorable rather than unfavorable. Study 1 demonstrated that regret, but not other negative emotions, was dominated by positive more than negative evaluations. In both studies 1 and 2, although participants saw a great deal of benefit from their negative emotions, regret stood out as particularly beneficial. Indeed, in study 2, regret was seen to be the most beneficial of 12 negative emotions on all five functions of: making sense of past experiences, facilitating approach behaviors, facilitating avoidance behaviors, gaining insights into the self, and in preserving social harmony. Moreover, in study 2, individuals made self-serving ascriptions of regret, reporting greater regret experiences for themselves than for others. In short, people value their regrets substantially more than they do other negative emotions.

  10. An assessment on the incremental value of high-resolution magnetic resonance imaging to identify culprit plaques in atherosclerotic disease of the middle cerebral artery

    International Nuclear Information System (INIS)

    Teng, Zhongzhao; Graves, Martin J.; Gillard, Jonathan H.; Peng, Wenjia; Zhan, Qian; Zhang, Xuefeng; Liu, Qi; Chen, Shiyue; Tian, Xia; Chen, Luguang; Lu, Jianping; Brown, Adam J.

    2016-01-01

    Although certain morphological features depicted by high resolution, multi-contrast magnetic resonance imaging (hrMRI) have been shown to be different between culprit and non-culprit middle cerebral artery (MCA) atherosclerotic lesions, the incremental value of hrMRI to define culprit lesions over stenosis has not been assessed. Patients suspected with MCA stenosis underwent hrMRI. Lumen and outer wall were segmented to calculate stenosis, plaque burden (PB), volume (PV), length (PL) and minimum luminal area (MLA). Data from 165 lesions (112 culprit and 53 non-culprit) in 139 individuals were included. Culprit lesions were larger and longer with a narrower lumen and increased PB compared with non-culprit lesions. More culprit lesions showed contrast enhancement. Both PB and MLA were better indicators than stenosis in differentiating lesion types (AUC were 0.649, 0.732 and 0.737 for stenosis, PB and MLA, respectively). Combinations of PB, MLA and stenosis could improve positive predictive value (PPV) and specificity significantly. An optimal combination of stenosis ≥ 50 %, PB ≥ 77 % and MLA ≤ 2.0 mm 2 produced a PPV = 85.7 %, negative predictive value = 54.1 %, sensitivity = 69.6 %, specificity = 75.5 %, and accuracy = 71.5 %. hrMRI plaque imaging provides incremental information to luminal stenosis in identifying culprit lesions. (orig.)

  11. Value of magnetic resonance imaging in prenatal diagnosis of placental accretism

    International Nuclear Information System (INIS)

    Francisco, Viviane Vieira; Goldman, Suzan Menasce; Faria, Juliano; Szejnfeld, Jacob

    2006-01-01

    Purpose: to establish the main signs of placental accretism in magnetic resonance imaging (MRI) in patients with clinical suspicion and to estimate the benefit of this method. Methods: prospective transversal study with 15 patients suspected of placental accretism, referred between March 2003 and February 2006. Gestational age varied from 20 to 31 weeks. All patients underwent MRI to study the placenta and had previously done an ultrasonography. Material was sent to histological study. MRI was done on Magnetom Impact and Sonata Maestro Class Siemens R , with acquired sequences HASTE, TURBO SPIN in axial, sagittal, coronal planes and echo gradient (GE R ), pre- and post-dynamic contrast in the best plan for acquisition. Images were analyzed by a team of two radiologists. Results: mean gestational age was 24.3 weeks. We studied seven placenta previa (47%), six anterior placentas (40%) and two posterior placentas (13%). Ultrasonography was positive in 80% of the placentas and MRI in 53%. However, echography had a low concordance with anatomic pathological studies by Kappa test (11%), revealing 75% of sensitivity, 14% of specificity, 50% as positive predictive value (PPV) and 33% as negative predictive value (NPV). MRI had an excellent concordance with anatomic pathological studies (0.86), showing 100% of sensitivity, 86% of specificity, 89% as PPV and 100% as NPV. Conclusions: MRI is useful for placental accretism diagnosis. The principal findings are transmural hyper-signal, the loss of continuity in myometrial wall in fast sequences and the identification of vessels invading myometrial layer in dynamic sequences. (author)

  12. Differentiating benign from malignant solid breast masses: value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification.

    Science.gov (United States)

    Evans, A; Whelehan, P; Thomson, K; Brauer, K; Jordan, L; Purdie, C; McLean, D; Baker, L; Vinnicombe, S; Thompson, A

    2012-07-10

    The aim of this study was to assess the performance of shear wave elastography combined with BI-RADS classification of greyscale ultrasound images for benign/malignant differentiation in a large group of patients. One hundred and seventy-five consecutive patients with solid breast masses on routine ultrasonography undergoing percutaneous biopsy had the greyscale findings classified according to the American College of Radiology BI-RADS. The mean elasticity values from four shear wave images were obtained. For mean elasticity vs greyscale BI-RADS, the performance results against histology were sensitivity: 95% vs 95%, specificity: 77% vs 69%, Positive Predictive Value (PPV): 88% vs 84%, Negative Predictive Value (NPV): 90% vs 91%, and accuracy: 89% vs 86% (all P>0.05). The results for the combination (positive result from either modality counted as malignant) were sensitivity 100%, specificity 61%, PPV 82%, NPV 100%, and accuracy 86%. The combination of BI-RADS greyscale and shear wave elastography yielded superior sensitivity to BI-RADS alone (P=0.03) or shear wave alone (P=0.03). The NPV was superior in combination compared with either alone (BI-RADS P=0.01 and shear wave P=0.02). Together, BI-RADS assessment of greyscale ultrasound images and shear wave ultrasound elastography are extremely sensitive for detection of malignancy.

  13. Comparison of kVp and PPV measurements between a constant potential and a clinical X-ray system used for calibration in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Eduardo de L.; Vivolo, Vitor; Potiens, Maria da Penha A., E-mail: vivolo@ipen.b, E-mail: mppalbu@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The PPV is an electrical quantity that relates the peak voltage with the radiological image contrast, thus having a larger clinical application. By definition, in an X-ray system, the 'PPV is a quantity based on the concept that the radiation generated by a high voltage source with an arbitrary wave source produces the same radiographic contrast that the radiation generated by a high voltage source with an equivalent constant potential'. The Instruments Calibration Laboratory (LCI) of IPEN has the mammography qualities established in a constant potential system (industrial X-ray system), and also in a clinical system (mammograph). The objective of this study was to analyze the PPV behavior in these systems, and try to reach calibration conditions that are more similar to the work conditions in hospitals and clinics. For this, it was used an industrial X-ray (constant potential) and a mammography system (high frequency). The first system has a tungsten (W) target, and additional filtration of aluminum (Al) and molybdenum (Mo), and the second one has a Mo target and additional filtration of Mo and rhodium (Rh). A non-invasive measuring system from PTW model Diavolt was used to PPV determination. The voltages used were 25 kV, 28 kV, 30 kV and 35 kV (calibration qualities in mammography, according to the IEC 61267). The Diavolt was placed one meter from the focal spot in the industrial X-ray system, and 60 cm for the clinical system. (author)

  14. Photoactive Blends of Poly(para-phenylenevinylene) (PPV) with Methanofullerenes from a Novel Precursor : Photophysics and Device Performance

    NARCIS (Netherlands)

    Brabec, C.J.; Cravino, A.; Zerza, G.; Sariciftci, N.S.; Kiebooms, R.; Vanderzande, D.; Hummelen, J.C.

    2001-01-01

    Homogeneous blends of a processable methanofullerene, [6,6]-phenyl C61-butyric acid methyl ester (PCBM), with poly(para-phenylenevinylene) (PPV) synthesized using a novel nonionic precursor route were produced. These photoactive blends have been investigated by excited-state spectroscopy and by

  15. Prospect theory does not describe the feedback-related negativity value function.

    Science.gov (United States)

    Sambrook, Thomas D; Roser, Matthew; Goslin, Jeremy

    2012-12-01

    Humans handle uncertainty poorly. Prospect theory accounts for this with a value function in which possible losses are overweighted compared to possible gains, and the marginal utility of rewards decreases with size. fMRI studies have explored the neural basis of this value function. A separate body of research claims that prediction errors are calculated by midbrain dopamine neurons. We investigated whether the prospect theoretic effects shown in behavioral and fMRI studies were present in midbrain prediction error coding by using the feedback-related negativity, an ERP component believed to reflect midbrain prediction errors. Participants' stated satisfaction with outcomes followed prospect theory but their feedback-related negativity did not, instead showing no effect of marginal utility and greater sensitivity to potential gains than losses. Copyright © 2012 Society for Psychophysiological Research.

  16. The value of FDG-PET/CT in assessing single pulmonary nodules in patients at high risk of lung cancer

    International Nuclear Information System (INIS)

    Kagna, Olga; Solomonov, Anna; Fruchter, Oren; Keidar, Zohar; Bar-Shalom, Rachel; Israel, Ora; Yigla, Mordechai; Guralnik, Luda

    2009-01-01

    To evaluate whether PET/low-dose CT (ldCT) using 18 F-fluorodeoxyglucose (FDG) improves characterization of indeterminate single pulmonary nodules (SPNs) in patients at high risk of lung cancer. Retrospective analysis of 307 patients who underwent FDG-PET/CT for indeterminate SPNs identified 93 (70 men, age range 46-90 years) at high risk of lung cancer (age >40 years, minimum 10 pack-year smokers). SPNs were evaluated for the presence and intensity of FDG avidity and ldCT patterns. The performance of visual and semiquantitative FDG-PET/ldCT algorithms for characterization of SPNs was compared to that of ldCT. Incongruent FDG-PET and ldCT patterns were analyzed for significance in further patient management. Malignancy was diagnosed in 38% patients. FDG avidity defined 33 SPNs as true-positive (TP) and 2 as false-negative (FN) (malignant), and 41 as true-negative (TN) and 17 as false-positive (FP) (benign). For SUVmax of 2.2 (by ROC analysis) there were 27 TP, 8 FN, 48 TN and 10 FP SPNs. LdCT defined 34 TP, 1 FN, 28 TN and 30 FP lesions. Of the FP lesions on ldCT, 60% were FDG-negative. Visual PET/ldCT analysis had a sensitivity of 94%, a specificity of 70%, an accuracy of 80%, a positive predictive value (PPV) of 66%, and a negative predictive value (NPV) of 95% as compared to 77%, 83%, 81%, 73%, 86% for semiquantitative PET/ldCT and 97%, 48%, 66%, 53%, 96% for ldCT, respectively. Both PET/ldCT algorithms had statistically significantly higher specificity and accuracy than ldCT. Semiquantitative analysis showed significantly higher PPV and lower sensitivity and NPV than found with ldCT. A single screening procedure encompassing FDG-PET and ldCT may improve screening for lung cancer in high-risk patients. The significantly improved specificity may potentially reduce FP ldCT results and further unnecessary invasive procedures. (orig.)

  17. Predictive values of BI-RADS{sup ®} magnetic resonance imaging (MRI) in the detection of breast ductal carcinoma in situ (DCIS)

    Energy Technology Data Exchange (ETDEWEB)

    Badan, Gustavo Machado, E-mail: gustavobadan@hotmail.com [Breast Imaging Service of Radiology Depatment—Irmandade da Santa Casa de Misericórdia de São Paulo, São Paulo, SP (Brazil); Piato, Sebastião [Mastology Division—Gynecology and Obstetrics Department (Brazil); Roveda, Décio; Faria Castro Fleury, Eduardo de [Breast Imaging Service of Radiology Depatment—Irmandade da Santa Casa de Misericórdia de São Paulo, São Paulo, SP (Brazil)

    2016-10-15

    Purpose: The purpose of this study was to evaluate BI-RADS indicators in the detection of DCIS by MRI. Materials and methods: Prospective observational study that started in 2014 and lasted 24 months. A total of 110 consecutive patients were evaluated, who presented with suspicious or highly suspicious microcalcifications on screening mammography (BI-RADS categories 4 and 5) and underwent stereotactic-guided breast biopsy, having had an MRI scan performed prior to biopsy. Results: Altogether, 38 cases were characterized as positive for malignancy, of which 25 were DCIS and 13 were invasive ductal carcinoma cases. MRI had a sensitivity of 96%; specificity of 75.67%; positive predictive value (PPV) for DCIS detection of 57.14%; negative predictive value (NPV) in the detection of DCIS of 98.24%; and an accuracy of 80.80%. Conclusion: BI-RADS as a tool for the detection of DCIS by MRI is a powerful instrument whose sensitivity was higher when compared to that observed for mammography in the literature. Likewise, the PPV obtained by MRI was higher than that observed in the present study for mammography, and the high NPV obtained on MRI scans can provide early evidence to discourage breast biopsy in selected cases.

  18. Diagnostic value of pleural fluid adenosine deaminase activity in tuberculosis pleurisy

    Directory of Open Access Journals (Sweden)

    Abbas ali Niazi

    2009-09-01

    Full Text Available Background: Diagnosis of tuberculosis pleurisies is difficult because of its nonspecific clinical presentation and insufficient traditional diagnostic methods. We investigated the use of adenosine deaminase (ADA activity in tuberculosis pleurisies. Methods: A number of 85 patients were analyzed with exudative pleural effusions. Using the ROC curve, we determined the optimal cutoff for TB pleurisy. Results: A number of 58 exudative samples were nontuberculous (non-TB and 27 were tuberculosis (TB. There was statistically significant difference (p<0.0001 between the means of pleural fluid ADA levels among the TB and non-TB populations. The prevalence of TB pleurisy in the studied population was 31%. Using the cutoff point equal to 35 for diagnosing TB effusions the sensitivity and specificity 70.3% and 91.3%, respectively. The positive predictive value (PPV was 79.1% and the negative predictive value (NPV was 86.8%. A pleural fluid ADA value <19 IU/L suggests that a tuberculosis effusion is highly unlikely. Conclusion: Pleural fluid total ADA assay is a sensitive and specific test suitable for rapid diagnosis of TB pleurisy.

  19. Value of digital radiography in expiration in detection of pneumothorax; Wertigkeit der digitalen Roentgenaufnahme in Exspiration zum Nachweis eines Pneumothorax

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, L.; Natho, O.; Feigen, U.; Kivelitz, D. [Asklepios Klinik St. Georg, Hamburg (Germany). Dept. of Radiology; Schulz, U. [medistat GmbH, Kiel (Germany). Medical Statistics

    2014-03-15

    Purpose: The purpose of this study was to find out whether pneumothorax detection and exclusion is superior in expiratory digital chest radiography. Materials and Methods: 131 patients with pneumothorax with paired inspiratory and expiratory chest radiographs were analyzed regarding localization and size of pneumothorax. Sensitivity, specificity, negative (npv) and positive predictive value (ppv) as well as the positive (LR+) and negative likelihood ratio (LR-) were determined in a blinded randomized interobserver study with 116 patients. The evaluation was performed by three board-certified radiologists. Results: In 131 patients, there were 139 pneumothoraces, 135 (97.1 %) were located apical, 88 (63.3 %) lateral and 33 (23.7 %) basal. Sensitivity was 99 % for inspiratory and 97 % for expiratory radiographs. The interobserver study yielded a mean sensitivity of 86.1 %/86.1 %, specificity of 97.3 %/93.4 %, npv of 88.7 %/88.5 % and ppv of 96.7 %/92.1 % for inspiration/expiration. For inspiratory radiographs the LR+/LR- were 40.2/0.14 and for expiration 13.9 and 0.15. McNemar-Test showed no significant difference for the detection of pneumothoraces in in-/exspiration. Conclusion: Inspiratory and expiratory digital radiographs are equally suitable for pneumothorax detection. Inspiratory radiographs are recommended as the initial examination of choice for pneumothorax detection, an additional expiratory radiograph is only recommended in doubtful cases. (orig.)

  20. Impact of the endoscopist's experience on the negative predictive value of capsule endoscopy.

    Science.gov (United States)

    Velayos Jiménez, Benito; Alcaide Suárez, Noelia; González Redondo, Guillermo; Fernández Salazar, Luis; Aller de la Fuente, Rocío; Del Olmo Martínez, Lourdes; Ruiz Rebollo, Lourdes; González Hernández, José Manuel

    2017-01-01

    The impact of the accumulated experience of the capsule endoscopy (CE) reader on the accuracy of this test is discussed. To determine whether the negative predictive value of CE findings changes along the learning curve. We reviewed the first 900 CE read by 3 gastroenterologists experienced in endoscopy over 8 years. These 900 CE were divided into 3 groups (300 CE each): group 1 consisted of the sum of the first 100 CE read by each of the 3 endoscopists; group 2, the sum of the second 100 and groups 3, the sum of the third 100. Patients with normal CE were monitored for at least 28 months to estimate the negative predictive value. A total of 54 (18%) CE in group 1, 58 (19.3%) in group 2 and 47 (15.6%) in group 3 were normal, although only 34 patients in group 1, 38 in group 2 and 36 in group 3 with normal CE completed follow up and were eventually studied. The negative predictive value was 88.2% in group 1, 89.5% in group 2 and 97% in group 3 (P>.05). The negative predictive value tended to increase, but remained high and did not change significantly after the first 100 when readers are experienced in conventional endoscopy and have preliminary specific training. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  1. Film morphology effects on the electrical and optical properties of bulk heterojunction organic solar cells based on MEH-PPV/C60 composite

    International Nuclear Information System (INIS)

    Ltaief, A.; Davenas, J.; Bouazizi, A.; Ben Chaabane, R.; Alcouffe, P.; Ben Ouada, H.

    2005-01-01

    The influence of film morphology on the electrical behaviour of an MEH-PPV/C 60 organic solar cells has been investigated. The dissociation of photogenerated charge pairs in composites of buckminsterfullerenes (C 60 ) in a conjugated polymer matrix (MEH-PPV) forming dispersed heterojunctions was studied at low C 60 acceptor concentrations to separate electron transfer from charge transport effects. The motivation of this study was to analyse the strong dependence of organic solar cell efficiencies on the morphology of the composite. Two effects controlling film morphology have been investigated; the first one being the influence of the fullerene concentration and the second one is the effect of the organic solvent used to deposit the photoactive layer. The sample morphology was studied using atomic force microscopy (AFM). Photoluminescence (PL) experiments and current-voltage (I-V) measurements were performed on the deposited photovoltaic film to investigate the influence of dispersion on the charge transfer process between MEH-PPV and C 60 . An attempt to explain all the results will be presented

  2. Investigation of electrical and optical properties of MEH-PPV: ZnO nanocomposite films for OLED applications

    Energy Technology Data Exchange (ETDEWEB)

    Azhar, N. E. A., E-mail: najwaezira@yahoo.com; Shafura, A. K., E-mail: shafura@ymail.com; Affendi, I. H. H., E-mail: irmahidayanti.halim@gmail.com; Shariffudin, S. S., E-mail: sobihana@gmail.com [NANO-ElecTronic Centre, Faculty of Electrical Engineering, Universiti Teknologi MARA (UiTM), 40450 Shah Alam, Selangor (Malaysia); Saurdi, I., E-mail: saurdy788@gmail.com [Faculty of Electrical Engineering, UiTM Sarawak, Kampus Kota Meranek, Sarawak (Malaysia); Alrokayan, Salman A. H., E-mail: dr.salman@alrokayan.com; Khan, Haseeb A., E-mail: khan-haseeb@yahoo.com [Research Chair of Targeting and Treatment of Cancer Using Nanoparticles Department of Biochemistry, College of Science, King Saud University (KSU), 245 Riyadh 11454 (Saudi Arabia); Rusop, M., E-mail: rusop@salam.uitm.edu.my [NANO-ElecTronic Centre, Faculty of Electrical Engineering, Universiti Teknologi MARA (UiTM), 40450 Shah Alam, Selangor (Malaysia); NANO-SciTech Centre, Institute of Science, Universiti Teknologi MARA (UiTM), Shah Alam, Selangor (Malaysia)

    2016-07-06

    Recent investigations of the promising materials for optoelectronic have been demonstrated by introducing n-type inorganic material into conjugated polymer. The optical and electrical of nanocomposite films based on poly[2-methoxy-5-(2’-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) and zinc oxide (ZnO) nanostructured of various deposition layers (1 to 3 layers) have been investigated. The MEH-PPV: ZnO nanocomposite films were deposited using spin-coating technique. The surface morphology nanocomposite films were characterized using field emission scanning electron microscope. From surface profiler measurement, we found that the thickness of nanocomposite films increased as deposition time increased. The optical properties were measured using photoluminescence spectroscope. The photoluminescence (PL) spectra showed that two deposition layers is the highest intensity at visible region (green emission) due to high energy transfer from particles to the polymer. The current density for two layers sample is due to aggregation of conjugated polymer chain hence form excited interchain exciton for optical excitation. This study will provide better performance and suitable for optoelectronic device especially OLEDs application.

  3. Photovoltage method for the research of CdS and ZnO nanoparticles and hybrid MEH-PPV/nanoparticle structures

    Czech Academy of Sciences Publication Activity Database

    Toušková, J.; Toušek, J.; Rohovec, Jan; Růžička, A.; Polonskyi, O.; Urbánek, P.; Kuřitka, I.

    2014-01-01

    Roč. 16, č. 3 (2014), Art. 2314 ISSN 1388-0764 Institutional support: RVO:67985831 Keywords : CdS * energy conversion * MEH-PPV * nanoparticles * photovoltage spectra * transmission electron microscopy * ZnO Subject RIV: DD - Geochemistry Impact factor: 2.184, year: 2014

  4. Contrast-enhanced CT in determining resectability in patients with pancreatic carcinoma: a meta-analysis of the positive predictive values of CT

    Energy Technology Data Exchange (ETDEWEB)

    Somers, Inne; Bipat, Shandra [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2017-08-15

    To obtain a summary positive predictive value (sPPV) of contrast-enhanced CT in determining resectability. The MEDLINE and EMBASE databases from JAN2005 to DEC2015 were searched and checked for inclusion criteria. Data on study design, patient characteristics, imaging techniques, image evaluation, reference standard, time interval between CT and reference standard, and data on resectability/unresectablity were extracted by two reviewers. We used a fixed-effects or random-effects approach to obtain sPPV for resectability. Several subgroups were defined: 1) bolus-triggering versus fixed-timing; 2) pancreatic and portal phases versus portal phase alone; 3) all criteria (liver metastases/lymphnode involvement/local advanced/vascular invasion) versus only vascular invasion as criteria for unresectability. Twenty-nine articles were included (2171 patients). Most studies were performed in multicentre settings, initiated by the department of radiology and retrospectively performed. The I{sup 2}-value was 68%, indicating heterogeneity of data. The sPPV was 81% (95%CI: 75-86%). False positives were mostly liver, peritoneal, or lymphnode metastases. Bolus-triggering had a slightly higher sPPV compared to fixed-timing, 87% (95%CI: 81-91%) versus 78% (95%CI: 66-86%) (p = 0.077). No differences were observed in other subgroups. This meta-analysis showed a sPPV of 81% for predicting resectability by CT, meaning that 19% of patients falsely undergo surgical exploration. (orig.)

  5. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  6. Anthracene-containing PPE-PPV copolymers: Effect of side-chain nature and length on photophysical and photovoltaic properties

    Czech Academy of Sciences Publication Activity Database

    Jadhav, R.; Türk, S.; Kühnlenz, F.; Cimrová, Věra; Rathgeber, S.; Egbe, D. A. M.; Hoppe, H.

    2009-01-01

    Roč. 206, č. 12 (2009), s. 2695-2699 ISSN 1862-6300 R&D Projects: GA MŠk(CZ) 1M06031 Institutional research plan: CEZ:AV0Z40500505 Keywords : PPE-PPV copolymers * solar cells Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.228, year: 2009

  7. A study of asymptomatic bacteriuria in Egyptian school-going children.

    African Journals Online (AJOL)

    Background: Urinary tract infections (UTI) are a common and important clinical problem in childhood. Upper urinary ... tive predictive value (PPV) and negative predictive value. (NPV) in ... nificant bacteriuria in asymptomatic school children by.

  8. Band gap engineering for poly(p-phenylene) and poly(p-phenylene vinylene) copolymers using the tight-binding approach

    Science.gov (United States)

    Giro, R.; Caldas, M. J.; Galvão, D. S.

    The interest in poly(p-phenylene) (PPP) and poly(p-phenylene vinylene) (PPV) copolymers stems from the fact that these homopolymers present interesting optical and electronic properties that allow a great variety of technological applications. Combining different numbers of PPP and PPV units it is possible, in principle, to obtain new structures presenting intermediate gap values (2.8 eV and 2.4 eV for PPP and PPV, respectively). For this study we used a Hückel Hamiltonian tight-binding coupled to the negative factor counting (NFC) technique. We carried out a systematic search to determine optimum relative concentrations for disordered binary polymeric alloys with predefined gap values. Once these structures were obtained, we used the semiempirical methods AM1/PM3 and ZINDO/S-CI for geometrical and optical studies, respectively. Our theoretical results show that it is possible to obtain copolymers of PPP and PPV with intermediate gap values of their parent structures.

  9. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    Energy Technology Data Exchange (ETDEWEB)

    Itatani, R., E-mail: banguliao@gmail.com [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Namimoto, T. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Atsuji, S.; Katahira, K.; Morishita, S. [Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitani, K.; Hamada, Y. [Department of Urology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitaoka, M. [Department of Pathology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Nakaura, T. [Department of Diagnostic Radiology, Amakusa Medical Center, Kameba 854-1, Amakusa, Kumamoto 863-0046 (Japan); Yamashita, Y. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan)

    2014-10-15

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy.

  10. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    International Nuclear Information System (INIS)

    Itatani, R.; Namimoto, T.; Atsuji, S.; Katahira, K.; Morishita, S.; Kitani, K.; Hamada, Y.; Kitaoka, M.; Nakaura, T.; Yamashita, Y.

    2014-01-01

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy

  11. Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

    International Nuclear Information System (INIS)

    Zhang, Jian Jun; Liu, Tie; Feng, Yue; Wu, Wei Feng; Mou, Cai Yun; Zhai, Li Hao

    2011-01-01

    We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses (≥ 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen's Kappa statistics were calculated for the intermodality and interobserver agreement. The mean heart rate was 89 ± 8.3 bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen's Kappa statistics demonstrated good intermodality and interobserver agreement. 64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.

  12. Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian Jun; Liu, Tie; Feng, Yue; Wu, Wei Feng; Mou, Cai Yun; Zhai, Li Hao [Zhejiang Hospital, Hangzhou (China)

    2011-08-15

    We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses ({>=} 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen's Kappa statistics were calculated for the intermodality and interobserver agreement. The mean heart rate was 89 {+-} 8.3 bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen's Kappa statistics demonstrated good intermodality and interobserver agreement. 64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.

  13. Solution Path for Pin-SVM Classifiers With Positive and Negative $\\tau $ Values.

    Science.gov (United States)

    Huang, Xiaolin; Shi, Lei; Suykens, Johan A K

    2017-07-01

    Applying the pinball loss in a support vector machine (SVM) classifier results in pin-SVM. The pinball loss is characterized by a parameter τ . Its value is related to the quantile level and different τ values are suitable for different problems. In this paper, we establish an algorithm to find the entire solution path for pin-SVM with different τ values. This algorithm is based on the fact that the optimal solution to pin-SVM is continuous and piecewise linear with respect to τ . We also show that the nonnegativity constraint on τ is not necessary, i.e., τ can be extended to negative values. First, in some applications, a negative τ leads to better accuracy. Second, τ = -1 corresponds to a simple solution that links SVM and the classical kernel rule. The solution for τ = -1 can be obtained directly and then be used as a starting point of the solution path. The proposed method efficiently traverses τ values through the solution path, and then achieves good performance by a suitable τ . In particular, τ = 0 corresponds to C-SVM, meaning that the traversal algorithm can output a result at least as good as C-SVM with respect to validation error.

  14. X-rays sensing properties of MEH-PPV, Alq₃ and additive components: a new organic dosimeter as a candidate for minimizing the risk of accidents of patients undergoing radiation oncology.

    Science.gov (United States)

    Schimitberger, T; Ferreira, G R; Akcelrud, L C; Saraiva, M F; Bianchi, R F

    2013-01-01

    In this paper, we report our experimental design in searching a smart and easy-to-read dosimeter used to detect 6 MV X-rays for improving patient safety in radiation oncology. The device was based on an organic emissive solutions of poly(2-methoxy-5(2'-ethylhexyloxy)-p-phenylenevinylene) (MEH-PPV), aluminum-tris-(8-hydroxyquinoline) (Alq₃) and additive components which were characterized by UV-Vis absorption, photoluminescence and CIE color coordinate diagram. The optical properties of MEH-PPV/Alq₃ solutions have been examined as function of radiation dose over the range of 0-100 Gy. It has shown that MEH-PPV/Alq₃ solutions are specifically sensitive to X-rays, since the effect of radiation on this organic system is strongly correlated with the efficient spectral overlap between Alq₃ emission and the absorption of degraded MEH-PPV, which alters the color and photoemission of MEH-PPV/Alq₃ mixtures from red to yellow, and then to green. The rate of this change is more sensitive when MEH-PPV/Alq₃ is irradiated in the presence of benzoyl peroxide than when in the presence of hindered phenolic stabilizers, respectively, an accelerator and an inhibitor to activate or inhibit free radical formation. This gives rise to optimize the response curve of the dosimeter. It is clear from the experimental results that organic emissive semiconductors have potential to be used as dedicated and low-cost dosimeters to provide an independent check of beam output of a linear accelerator and therefore to give patients the opportunity to have information on the dose prescription or equipment-related problems a few minutes before being exposed to radiation. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Lumbar internal disc derangement in patients with chronic low back pain: diagnostic value of the MR imaging findings as compared with provoked discography as the standard

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyeon Seon; Park, Jee Young; Lee, Sang Ho; Ahn, Yong [Wooridul spine Hospital, Seoul (Korea, Republic of); Lee, Sang Yeun [Puchon Daesung Hospital, Puchon (Korea, Republic of)

    2006-04-15

    The aim of this study was to evaluate the diagnostic value of the MR imaging findings with provoked discography used as the standard for painful lumbar disc derangement. Two hundred patients (412 discs), (age rang: 21-77 year), with chronic low back pain underwent MRI and provoked discography. We evaluated the MRI T2-WI findings such as disc degeneration, high-Intensity zones and endplate abnormalities. Subsequently, provocative discography was independently performed with using MR imaging, and a painful disc was defined when moderate to severe and concordant pain was provoked. We calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the MRI findings with using provoked discography as the standard. 400 discs showed abnormal findings such as disc degeneration, HIZ and endplate abnormalities on the T2-WI images. 12 discs showed normal finding. HIZ or endplate abnormalities were always combined with disc degeneration. The prevalence of each findings were disc degeneration (400 discs: 97.1%), HIZ (111 discs: 26.9%), type I endplate abnormalities (34 discs: 8.3%), type II endplate abnormalities (75 discs: 18.2%), the combined findings of HIZ and type I endplate abnormalities (2 discs: 0.5%) and the combined findings of HIZ and type II endplate abnormalities (7 discs: 1.7%). The disc degeneration showed high sensitivity (99.5%) and low specificity (5.0%), so only the NPV (91.7%) was significant, and not the PPV (47.8%). Each findings of HIZ (sensitivity, 36.5%, specificity, 81.4%; PPV, 63.18%; NPV, 59.5%), type I endplate abnormalities (11.0%, 94.1%, 61.8% and 54.8%, respectively), type II endplate abnormalities (19.8%, 83.2%, 50.7% and 54.3%, respectively), the combined findings of HIZ and type I endplate abnormalities (0.5%, 99.6%, 50.0% and 53.4%, respectively) and the combined findings of HIZ and type II endplate abnormalities (26.0%, 99.1%, 71.4% and 53.8%, respectively) show high specificity, but low

  16. Lumbar internal disc derangement in patients with chronic low back pain: diagnostic value of the MR imaging findings as compared with provoked discography as the standard

    International Nuclear Information System (INIS)

    Park, Hyeon Seon; Park, Jee Young; Lee, Sang Ho; Ahn, Yong; Lee, Sang Yeun

    2006-01-01

    The aim of this study was to evaluate the diagnostic value of the MR imaging findings with provoked discography used as the standard for painful lumbar disc derangement. Two hundred patients (412 discs), (age rang: 21-77 year), with chronic low back pain underwent MRI and provoked discography. We evaluated the MRI T2-WI findings such as disc degeneration, high-Intensity zones and endplate abnormalities. Subsequently, provocative discography was independently performed with using MR imaging, and a painful disc was defined when moderate to severe and concordant pain was provoked. We calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the MRI findings with using provoked discography as the standard. 400 discs showed abnormal findings such as disc degeneration, HIZ and endplate abnormalities on the T2-WI images. 12 discs showed normal finding. HIZ or endplate abnormalities were always combined with disc degeneration. The prevalence of each findings were disc degeneration (400 discs: 97.1%), HIZ (111 discs: 26.9%), type I endplate abnormalities (34 discs: 8.3%), type II endplate abnormalities (75 discs: 18.2%), the combined findings of HIZ and type I endplate abnormalities (2 discs: 0.5%) and the combined findings of HIZ and type II endplate abnormalities (7 discs: 1.7%). The disc degeneration showed high sensitivity (99.5%) and low specificity (5.0%), so only the NPV (91.7%) was significant, and not the PPV (47.8%). Each findings of HIZ (sensitivity, 36.5%, specificity, 81.4%; PPV, 63.18%; NPV, 59.5%), type I endplate abnormalities (11.0%, 94.1%, 61.8% and 54.8%, respectively), type II endplate abnormalities (19.8%, 83.2%, 50.7% and 54.3%, respectively), the combined findings of HIZ and type I endplate abnormalities (0.5%, 99.6%, 50.0% and 53.4%, respectively) and the combined findings of HIZ and type II endplate abnormalities (26.0%, 99.1%, 71.4% and 53.8%, respectively) show high specificity, but low

  17. Predictive values of early rest/24 hour delay Tl-201 perfusion SPECT for wall motion improvement in patients with acute myocardial infarction after reperfusion

    International Nuclear Information System (INIS)

    Hyun, In Young; Kwan, June

    1998-01-01

    We studied early rest/24 hour delay Tl-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Among 17 patients (male/female=11/6, age: 59±13) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay:11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest Tl-201 perfusion SPECT less then 6 hours after reperfusion and delay Tl-201 perfusion SPECT next day. Tl-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest Tl-201 uptake ≤2 or combination of rest Tl-201 uptake ≤2 or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ≥1 grade in follow up echo compared with the baseline values. Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest Tl-201uptake were 99%, and 54%.PPV and NPV of rest Tl-201 uptake were 100% and 52% respectively. Predictive values of comibination of rest Tl-201 uptake and late reversibility were not significantly different compared with predictive values of rest Tl-201 uptake only. We conclude that early Tl-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative

  18. Prospective Cohort Study Evaluating the Prognostic Value of Simple EEG Parameters in Postanoxic Coma.

    Science.gov (United States)

    Azabou, Eric; Fischer, Catherine; Mauguiere, François; Vaugier, Isabelle; Annane, Djillali; Sharshar, Tarek; Lofaso, Fréderic

    2016-01-01

    We prospectively studied early bedside standard EEG characteristics in 61 acute postanoxic coma patients. Five simple EEG features, namely, isoelectric, discontinuous, nonreactive to intense auditory and nociceptive stimuli, dominant delta frequency, and occurrence of paroxysms were classified yes or no. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic curve (AUC) of each of these variables for predicting an unfavorable outcome, defined as death, persistent vegetative state, minimally conscious state, or severe neurological disability, as assessed 1 year after coma onset were computed as well as Synek's score. The outcome was unfavorable in 56 (91.8%) patients. Sensitivity, specificity, PPV, NPV, and AUC of nonreactive EEG for predicting an unfavorable outcome were 84%, 80%, 98%, 31%, and 0.82, respectively; and were all very close to the ones of Synek score>3, which were 82%, 80%, 98%, 29%, and 0.81, respectively. Specificities for predicting an unfavorable outcome were 100% for isoelectric, discontinuous, or dominant delta activity EEG. These 3 last features were constantly associated to unfavorable outcome. Absent EEG reactivity strongly predicted an unfavorable outcome in postanoxic coma, and performed as accurate as a Synek score>3. Analyzing characteristics of some simple EEG features may easily help nonneurophysiologist physicians to investigate prognostic issue of postanoxic coma patient. In this study (a) discontinuous, isoelectric, or delta-dominant EEG were constantly associated with unfavorable outcome and (b) nonreactive EEG performed prognostic as accurate as a Synek score>3. © EEG and Clinical Neuroscience Society (ECNS) 2015.

  19. The diagnostic utility of the PSA screening test in a Ghanaian population

    International Nuclear Information System (INIS)

    Gyamfi, O.K.; Aryeetey, D.G.; Achel, D.G.; Gyasi, R. K.

    2004-01-01

    An immunoradiometric (IRMA) protocol was used in the PSA test to measure PSA levels in the sera of 240 men presenting with various complaints bordering on their prostate condition. These men were also made to undergo a fine-needle biopsy. Using the universal cut-off of 4.0ng/ml and the histopathological findings from the biopsies as a 'gold standard' statistical performance criteria (such as Sensitivity, Specificity, False Positive Ratio (FP), False Negative Ratio (FN), Likelihood Ratio (L), Positive Predictive Value (PPV), Negative Predictive Value (NPV), Prior Odds Ratio (Ω and Prevalence) were determined and compared with available literature values. This was to determine the diagnostic efficiency and utility of the PSA test for our Ghanaian population of 240 men. The test returned a Sensitivity and Specificity of 92.9% and 18.6% respectively. The FP and FN ratios were 81.4% and 7.1% respectively. The PPV and NPV were 38.1% and 82.9% respectively while the Prior Odds and Prevalence were 7:13 and 35% respectively. High sensitivities ranging from 79-90% and as low as 34 % have been reported. On the other hand specificities ranging from 59% to 70% have also been reported. The PPV compares favourably with the available literature values to us: within range 28-40%. The PPV and NPV values together with an application of Baye's theorem indicates that in our setting the PSA test is more efficient in ruling out disease than in detecting it. (au)

  20. Seroprevalence of varicella antibodies among pregnant women in Lyon-France

    International Nuclear Information System (INIS)

    Saadatian-Elahi, M.; Mekki, Y.; Signore, C. del; Lina, B.; Derrough, T.; Caulin, E.; Thierry, J.; Vanhems, P.

    2007-01-01

    The purpose of the study was to calculate the seroprevalence of immunity to the varicella-zoster virus (VZV) infection and to evaluate the positive predictive value (PPV) and the negative predictive value (NPV) of the self-reported history of VZV infection in pregnant women. A cross sectional study was conducted in 18 private medical analysis laboratories. Information on socio-demographic characteristics and past history of varicella or zoster were collected using a questionnaire. Blood samples were obtained to determine the serological levels of past exposure to VZV. Overall, 486 pregnant women were recruited. The seroprevalence of VZV antibodies was 98.8%. Six women were seronegative, of whom four were primiparous. The PPV was high (99.5%) while the NPV was only 10.3%. The PPV is a reliable marker of prior VZV infection. In contrast, a negative history does not predict lack of immunity and should be completed by serological analysis which might be introduced to routine antenatal blood tests

  1. Serum anti-PLA2R antibody as a diagnostic biomarker of idiopathic membranous nephropathy: The optimal cut-off value for Chinese patients.

    Science.gov (United States)

    Liu, Yipeng; Li, Xuan; Ma, Chaoqun; Wang, Ping; Liu, Ju; Su, Hong; Zhuo, Hao; Kong, Xianglei; Xu, Dayu; Xu, Dongmei

    2018-01-01

    The M-type phospholipase A2 receptor (PLA2R) is a specific target autoantigen identified in idiopathic membranous nephropathy (IMN). The autoantibody against PLA2R (anti-PLA2R) may be used to diagnose IMN. However, the appropriate diagnosis cut-off value for Chinese patients with IMN has not been established. In total, 119 patients who underwent renal biopsy (57 patients with IMN and 62 patients with non-IMN glomerulonephritis) and 22 healthy individuals were recruited for our observation study from Qianfoshan Hospital between September 2011 and March 2016. The serum concentration of anti-PLA2R was measured using a quantitative enzyme-linked immunosorbent assay (ELISA). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and receiver operating characteristic (ROC) curve of anti-PLA2R in diagnosing IMN were analysed based on the ELISA detection. The sensitivity, specificity, PPV, and NPV of anti-PLA2R in the diagnosis of IMN in the Chinese patients were 82.5, 75, 69.1, and 86.3% for the 2RU/ml cut-off value; 78.9, 91.7, 86.5, and 86.5% for the 2.6RU/ml cut-off value; 59.6, 95.2, 89.5, and 77.7% for the 14RU/ml cut-off value; 50.9, 96.4, 90.6, and 74.3% for the 20RU/ml cut-off value; and 47.4, 97.6, 93.1, and 73.2% for the 40RU/ml cut-off value, respectively. The area under the ROC curve was 0.879. The cut-off value of 2.6RU/ml is recommended for the use of anti-PLA2R for the diagnosis of IMN in Chinese patients based on the ELISA. Copyright © 2017. Published by Elsevier B.V.

  2. Mammography performance in Oman: Review of factors influencing cancer yield and positive predictive value.

    Science.gov (United States)

    Taif, Sawsan; Tufail, Fatma; Alnuaimi, Ahmed Sameer

    2016-06-01

    The aim of this study is to assess mammography performance in Oman by estimating the breast cancer rate and the positive predictive value (PPV) with the influence of some variables. This cross-sectional study was conducted on mammograms done in one of the three main breast imaging centers in Oman between January 2008 and July 2012. Diagnostic and screening groups were identified and assessed separately. Rate of abnormal mammograms, rate of breast cancer and the PPV were estimated according to Breast Imaging Reporting and Data System (BIRADS) score, presence of breast lump and patient's age. Total of 653 mammograms were included, 254 diagnostic and 399 screening. Abnormal mammograms (BIRADS 4 and 5) form 31.9% of the diagnostic examinations compared with 6.8% of screening examinations. Breast cancer was present in 17.9% of the diagnostic compared with 1.0% of the screening group. The PPV of BIRADS 5 was 94.1%, and for BIRADS 4 was 37.1 and 26.7% for diagnostic and screening studies. Overall PPV for abnormal mammograms was 65.2% in the diagnostic and 26.7% in the screening group. Mammography PPV shows positive association with age (P = 0.039) while presence of breast lump has no significant effect on the PPV (P = 0.38). BIRADS 5 score was found to have a high cancer yield making it a strong predictor of cancer. Different results were obtained in the diagnostic compared with screening mammography with higher rates of abnormal mammograms and breast cancer. Mammography performance should be better in the older women. © 2014 Wiley Publishing Asia Pty Ltd.

  3. Preference-based comparative effectiveness and cost–effectiveness: a review and relevance of value-based medicine for vitreoretinal interventions.

    Science.gov (United States)

    Brown, Melissa M; Brown, Gary C; Lieske, Heidi B; Lieske, P Alexander

    2012-05-01

    This analysis discusses the comparative effectiveness and cost-effectiveness of vitreoretinal interventions, measured in quality-adjusted life years (QALYs) and percentage patient value (PPV gain, or improvement in quality of life and/or length of life). The material is relevant since the Patient Protection and Affordable Care Act enacted by Congress with the support of the President has emphasized the critical importance of patient-based preferences. The majority of preference-based, comparative effectiveness and cost-effectiveness vitreoretinal interventions assessed in the US healthcare literature are Value-Based Medicine analyses, thus comparable. These interventions confer a mean patient (human) value gain (improvement in quality of life) of 8.3% [SD 6.3%, 95% confidence interval (CI) + 2.6%]. The average cost-utility of these vitreoretinal interventions is US$23 026/QALY (SD US$24 508, 95% CI + US$8770). Most vitreoretinal interventions are very cost effective using a conventional US standard of US$50 000/QALY as the upper anchor for a very cost-effective intervention, and the World Health Organization of approximately US$142 200/QALY as the upper anchor for a cost-effective intervention. Most vitreoretinal interventions confer considerable patient value and are very cost effective. Further standardization across healthcare is needed in the preference-based, comparative and cost-utility (cost-effectiveness) arena. The metrics of PPV (percentage patient value) gain and US$/PPV (dollars expended per percentage patient value gain) or financial value gain may be more user-friendly than the QALY.

  4. Application value of different transformation zone types and its genetic relationship with high-risk HPV type in diagnosis and therapy of cervical disease.

    Science.gov (United States)

    Chen, Yan; Zhou, Jia-De

    2015-01-01

    This study aims to discuss the influence of different types of transformation zone (TZ) on positive surgical margin of loop electrosurgical excision procedure (LEEP) and the significance of infection of different genetic high-risk HPV for cervical intraepithelial neoplasm. The clinical data of patients who had CIN2+ and received LEEP during January to December 2013 was investigated. The conditions of positive surgical margin of patients of different transformation zone (type I, II, III) were analyzed. The clinical high-risk types of HPV were divided into three groups, including A5/6, A7 and A9, compared with the pathological conditions of pre-operation and post-operation of the patients in respective group. The results indicated that type III transformation zone is more likely to cause positive cutting margin. For CIN2+ patients, sensitivity and specificity are 0.89% and 79.56% in group A5/6, and negative and positive predicted value (NPV, PPV) are 40% and 5%. The sensitivity, specificity, NPV, PPV in group A7 is 12.5%, 44.08%, 29.49% and 21.21%, respectively. The sensitivity, specificity, NPV, PPV in group A9 is 88.99%, 87.09%, 85.26%, 81.51%, respectively. Transformation zone type was correlated positively with positive cutting margin percentage (r = 0.8732, P zone is more likely to cause pathological upgrades. In conclusion, different types of transformation zone and high-risk HPV have clinical significance in causing positive cutting margin of surgery and disease extent.

  5. Value of modern sonography in the assessment of meniscal lesions

    International Nuclear Information System (INIS)

    Wareluk, Pawel; Szopinski, Kazimierz T.

    2012-01-01

    The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age = 36.2 years, range = 16–70 years). Inclusion criteria for the study were twofold: clinical suspicion of meniscal injury and clinical indication for arthroscopy. Knee examination was performed with the Voluson 730 Expert ultrasound system (General Electric). After sonographic examination, all patients underwent arthroscopic procedures within 1–4 days. The final diagnosis of meniscal tears was taken from surgical reports. The overall sensitivity, specificity, positive predictive value and negative predictive value of sonographic examination in the assessment of meniscal tears amounted to 85.4%, 85.7%, 67.3% and 94.4%, respectively. The statistical parameters were not statistically different in medial and lateral menisci. Age, sex, body mass index (BMI), weight, physical activity, mechanism on injury, and time lapse from injury did not have a statistically significant impact on the usefulness of ultrasonography. The highest sensitivity (>90%) was obtained in medial menisci and in patients with a BMI > 25. The highest specificity (>90%) was obtained in lateral menisci, in patients after twisting injuries, in sports injuries, and in recent injuries (time lapse from the injury <1 month). The positive predictive value (PPV) of sonographic examination was higher than 90% only in recent injuries (<1 month), however, the negative predictive value of ultrasound is high, being less than 90% in males with lesions of lateral menisci and in sequelae of sports injuries

  6. Value of modern sonography in the assessment of meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wareluk, Pawel, E-mail: pwareluk@wum.edu.pl [Department of Diagnostic Imaging, Second Faculty of Medicine, Medical University of Warsaw, ul. Kondratowicza 8, 03-242 Warsaw (Poland); Szopinski, Kazimierz T., E-mail: kszopinski@wum.edu.pl [Department of Dental and Maxillofacial Radiology, First Faculty of Medicine, Medical University of Warsaw, ul. Nowogrodzka 59, 02-006 Warsaw (Poland)

    2012-09-15

    The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age = 36.2 years, range = 16–70 years). Inclusion criteria for the study were twofold: clinical suspicion of meniscal injury and clinical indication for arthroscopy. Knee examination was performed with the Voluson 730 Expert ultrasound system (General Electric). After sonographic examination, all patients underwent arthroscopic procedures within 1–4 days. The final diagnosis of meniscal tears was taken from surgical reports. The overall sensitivity, specificity, positive predictive value and negative predictive value of sonographic examination in the assessment of meniscal tears amounted to 85.4%, 85.7%, 67.3% and 94.4%, respectively. The statistical parameters were not statistically different in medial and lateral menisci. Age, sex, body mass index (BMI), weight, physical activity, mechanism on injury, and time lapse from injury did not have a statistically significant impact on the usefulness of ultrasonography. The highest sensitivity (>90%) was obtained in medial menisci and in patients with a BMI > 25. The highest specificity (>90%) was obtained in lateral menisci, in patients after twisting injuries, in sports injuries, and in recent injuries (time lapse from the injury <1 month). The positive predictive value (PPV) of sonographic examination was higher than 90% only in recent injuries (<1 month), however, the negative predictive value of ultrasound is high, being less than 90% in males with lesions of lateral menisci and in sequelae of sports injuries.

  7. Positive predictive value and impact of misdiagnosis of a heart failure diagnosis in administrative registers among patients admitted to a University Hospital cardiac care unit

    DEFF Research Database (Denmark)

    Mard, Shan; Nielsen, Finn Erland

    2010-01-01

    To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF.......To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF....

  8. Tuning the properties of an anthracene-based PPE-PPV copolymer by fine variation of its macromolecular parameters

    Czech Academy of Sciences Publication Activity Database

    Tinti, F.; Sabir, F. K.; Gazzano, M.; Righi, S.; Ulbricht, C.; Usluer, Ö.; Pokorná, Veronika; Cimrová, Věra; Yohannes, T.; Egbe, D. A. M.; Camaioni, N.

    2013-01-01

    Roč. 3, č. 19 (2013), s. 6972-6980 ISSN 2046-2069 R&D Projects: GA ČR GAP106/12/0827; GA ČR(CZ) GA13-26542S Institutional support: RVO:61389013 Keywords : anthracene-containing PPE-PPV copolymer * macromolecular parameters * structural and transport properties Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.708, year: 2013

  9. Anticorrelation between exciplex emission and photovoltaic efficiency in PPV polymer based solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Chunhong, Yin; Neher, Dieter [University of Potsdam, Institute of Physics, Am Neuen Palais 10, 14469 Potsdam (Germany); Kietzke, Thomas [University of Potsdam, Institute of Physics, Am Neuen Palais 10, 14469 Potsdam (Germany); nstitute of Materials Research and Engineering (IMRE), Research Link 3, 117602 Singapore (Singapore); Hoerhold, Hans-Heinrich [University of Jena, Institute of Organic Chemistry and Macromolecular Chemistry, Humboldtstr. 10, 07743 Jena (Germany)

    2007-07-01

    By studying the photoluminescence emission and photovoltaic properties of blends of PPV-based electron donating and accepting polymers, we observed a strict anticorrelation between the relative exciplex emission in the solid state and the photovoltaic efficiency of corresponding blend devices. Thermal annealing led to a decrease in exciplex emission accompanied by an increase in photovoltaic efficiency. Comparative studies on defined bi-layer geometries bilayer devices did not show any influence on the annealing step. Consequently, we conclude that the photocurrent is mainly determined by the efficiency to form free carriers rather than by the transport and free carrier recombination.

  10. Predictive value of the official cancer alarm symptoms in general practice

    DEFF Research Database (Denmark)

    Krasnik Huggenberger, Ivan; Andersen, John Sahl

    2015-01-01

    Introduction: The objective of this study was to investigate the evidence for positive predictive value (PPV) of alarm symptoms and combinations of symptoms for colorectal cancer, breast cancer, prostate cancer and lung cancer in general practice. Methods: This study is based on a literature search...

  11. Neutrophil CD64 has a high negative predictive value for exclusion ...

    African Journals Online (AJOL)

    Methods and results. In this prospective observational study, patients were classied into categories of infection, namely denite, probable and possible. Of 76 neonates, 1 had denite infection, 5 probable infection, 30 possible infection, and 32 no infection. .e neutrophil CD64 index at a cut-o. value of 1.8 had a high negative ...

  12. Regulatory Forum Opinion Piece*: The Value of Publishing Negative Scientific Study Data.

    Science.gov (United States)

    Boorman, Gary A; Foster, John R; Laast, Victoria A; Francke, Sabine

    2015-10-01

    Historically it has been easier to publish positive scientific results than negative data not supporting the research hypothesis. This appears to be increasing, with fewer negative studies appearing in the literature across many disciplines. Failure to recognize the value of negative results has important implications for the toxicology community. Implications include perpetuating scientific fields based upon selective or occasionally erroneous, positive results. One example is decreased vaccination rates and increased measles infections that can lead to childhood mortality following one erroneous positive study linking vaccination to adverse effects despite multiple negative studies. Publication of negative data that challenges existing paradigms enhances progress by stopping further investment in scientifically barren topics, decreases the use of animals, and focuses research in more fruitful areas. The National Toxicology Program (NTP) publishes both positive and negative rodent data. Retrospective analysis of the NTP database has provided insights on the carcinogenic process and in the gradual acceptance of using fewer animals in safety studies. This article proposes that careful publication of both positive and negative data can enhance product safety assessment, add robustness to safety determinations in the regulatory decision-making process, and should be actively encouraged by those determining journal editorial policy. © 2015 by The Author(s).

  13. Comparison of the Quantitative Values of C-14 and C-13 UBT to Reflect the Presence and Degree of Ongoing Helicobacter pylori Infection

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee

    2008-01-01

    A urea breath test (UBT) using C-14 or C-13 has been developed for identifying Helicobacter (H) pylori infection on the basis of urease production with release of labeled CO 2 . We investigated if the C-14 and C-13 UBT have the difference to reflect the presence and degree of H. pylori infection detected by gastroduodenoscopic biopsies (GBx) in the same patients. Thirty eight patients (M:F=28:10, age 53.4±13.0 yrs) with upper gastrointestinal symptoms such as indigestion, gastric fullness or pain consecutively underwent C-14 UBT, GBx and C-13 UBT within one week before medications. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (37 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (≥200 dpm), intermediate (50∼199 dpm) or negative (<50 dpm). For the C-13 UBT, the results were classified as positive (≥2.5) or negative (<2.5). The results of GBx with Giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT and C-13 UBT results with GBx grade as a gold standard. The prevalence of H. pylori infection by GBx with Giemsa stain was 25/38 (65.8%). In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.0%, 92.3%, 95.8%, 91.7% and 92.1%, respectively. However, the C-13 UBT had sensitivity, specificity, PPV, NPV and accuracy of 96.0%, 84.6%, 92.3%, 91.7% and 92.1%, respectively. The more significant correlation in C-14 than C-13 UBT (r=0.948 vs r=0.819, p<0.001) was found between the value of UBT and the grade of distribution of H. pylori infection. We conclude that the diagnostic performance between C-14 and C-13 UBT to detect H. pylori infection is not significantly different, but the value of C-14 UBT more

  14. Comparison of the Quantitative Values of C-14 and C-13 UBT to Reflect the Presence and Degree of Ongoing Helicobacter pylori Infection

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Seok Tae; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2008-06-15

    A urea breath test (UBT) using C-14 or C-13 has been developed for identifying Helicobacter (H) pylori infection on the basis of urease production with release of labeled CO{sub 2}. We investigated if the C-14 and C-13 UBT have the difference to reflect the presence and degree of H. pylori infection detected by gastroduodenoscopic biopsies (GBx) in the same patients. Thirty eight patients (M:F=28:10, age 53.4{+-}13.0 yrs) with upper gastrointestinal symptoms such as indigestion, gastric fullness or pain consecutively underwent C-14 UBT, GBx and C-13 UBT within one week before medications. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (37 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive ({>=}200 dpm), intermediate (50{approx}199 dpm) or negative (<50 dpm). For the C-13 UBT, the results were classified as positive ({>=}2.5) or negative (<2.5). The results of GBx with Giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT and C-13 UBT results with GBx grade as a gold standard. The prevalence of H. pylori infection by GBx with Giemsa stain was 25/38 (65.8%). In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.0%, 92.3%, 95.8%, 91.7% and 92.1%, respectively. However, the C-13 UBT had sensitivity, specificity, PPV, NPV and accuracy of 96.0%, 84.6%, 92.3%, 91.7% and 92.1%, respectively. The more significant correlation in C-14 than C-13 UBT (r=0.948 vs r=0.819, p<0.001) was found between the value of UBT and the grade of distribution of H. pylori infection. We conclude that the diagnostic performance between C-14 and C-13 UBT to detect H. pylori infection is not significantly different, but the value of C-14 UBT

  15. Operative characteristic of the myocardial perfusion of repose in the evaluation of the thoracic pain in urgencies

    International Nuclear Information System (INIS)

    Merlano, Sonia; Murgueitio, Ramon; Rodriguez, Edgard; Carvajal, Andres; Suarez, Martin

    2000-01-01

    Conventional emergency department testing strategies for patients with chest pain often provide equivocal diagnosis of coronary artery disease. This study was conducted in order to determine the sensitivity, specificity, positive predictive value (PPV) negative predictive value (NPV) and negative likelihood ratio (LR-) of the myocardial perfusion imaging with single photon emission computed tomography (SPECT) imaging at rest

  16. Predictive value of the korean academy of family medicine in-training examination for certifying examination.

    Science.gov (United States)

    Cho, Jung-Jin; Kim, Ji-Yong

    2011-09-01

    In-training examination (ITE) is a cognitive examination similar to the written test, but it is different from the Clinical Practice Examination of the Korean Academy of Family Medicine (KAFM) Certification Examination (CE). The objective of this is to estimate the positive predictive value of the KAFM-ITE for identifying residents at risk for poor performance on the three types of KAFM-CE. 372 residents who completed the KAFM-CE in 2011 were included. We compared the mean KAFM-CE scores with ITE experience. We evaluated the correlation and the positive predictive value (PPV) of ITE for the multiple choice question (MCQ) scores of 1st written test & 2nd slide examination, the total clinical practice examination scores, and the total sum of 2nd test. 275 out of 372 residents completed ITE. Those who completed ITE had significantly higher MCQ scores of 1st written test than those who did not. The correlation of ITE scores with 1st written MCQ (0.627) was found to be the highest among the other kinds of CE. The PPV of the ITE score for 1st written MCQ scores was 0.672. The PPV of the ITE score ranged from 0.376 to 0.502. The score of the KAFM ITE has acceptable positive predictive value that could be used as a part of comprehensive evaluation system for residents in cognitive field.

  17. Hole mobility enhancement of MEH-PPV film by heat treatment at T{sub g}

    Energy Technology Data Exchange (ETDEWEB)

    Kajiya, Daisuke [Natural Science Center for Basic Research and Development (N-BARD), Hiroshima University, 1-3-1 Kagamiyama, Higashi-hiroshima, Hiroshima 739-8526 (Japan); Koganezawa, Tomoyuki [Japan Synchrotron Radiation Research Institute, 1-1-1, Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Saitow, Ken-ichi, E-mail: saitow@hiroshima-u.ac.jp [Natural Science Center for Basic Research and Development (N-BARD), Hiroshima University, 1-3-1 Kagamiyama, Higashi-hiroshima, Hiroshima 739-8526 (Japan); Department of Chemistry, Graduate School of Science, Hiroshima University, 1-3-1 Kagamiyama, Higashi-hiroshima, Hiroshima 739-8526 (Japan)

    2015-12-15

    The hole mobility of poly[2-methoxy-5-(2′-ethylhexyloxy)-1,4-phenylene vinylene] (MEH-PPV) film was measured using the time-of-flight method. The hole mobility was enhanced 4-fold after annealing at around the glass transition temperature (T{sub g}). Optical, atomic force, and Kelvin force microscopies, and grazing-incidence X-ray diffraction measurements indicate the enhancement can be attributed to a homogeneous film structure, a homogeneous Fermi level energy, and a face-on oriented structure, all of which were established by annealing at T{sub g}.

  18. Diagnostic value of 18F-FDG-PET/CT for the follow-up and restaging of soft tissue sarcomas in adults.

    Science.gov (United States)

    Kassem, T W; Abdelaziz, O; Emad-Eldin, S

    2017-10-01

    The purpose of this study was to evaluate the clinical utility of 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 FDG) positron emission tomography (PET)/computed tomography (CT) ( 18 F-FDG-PET/CT) in the follow-up of adult patients with soft tissue sarcomas. We prospectively evaluated 37 consecutive patients with known soft tissue sarcoma with 18 F-FDG-PET/CT examination for suspected recurrence of disease. They were 21 men and 16 women with a mean age of 49.6±10.6 (SD) years (range, 34-75years). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 18 F-FDG-PET/CT examination were calculated on a per patient basis. 18 F-FDG-PET/CT showed an overall diagnostic accuracy of 91.8%, sensitivity of 90% and a specificity of 100%. The positive predictive value and negative predictive value were 100 and 70%, respectively. The 18 F-FDG-PET/CT interpretations were correct in 34/37 patients (91.8%). Incorrect interpretations occurred in three patients (8.1%). Reasons for false negative findings were low 18 F-FDG uptake of local recurrence in one patient and low 18 F-FDG uptake of subcentimetric inguinal lymph node metastases. 18 F-FDG-PET/CT has a high diagnostic value in the follow-up of patients with soft tissue sarcoma. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  19. Positive predictive value of additional synchronous breast lesions in whole-breast ultrasonography at the diagnosis of breast cancer: clinical and imaging factors

    International Nuclear Information System (INIS)

    Kim, Ah Hyun; Kim, Min Jung; Kim, Eun Kyung; Moon, Hee Jung; Park, Hee Jung

    2014-01-01

    To evaluate the positive predictive value (PPV) of bilateral whole-breast ultrasonography (BWBU) for detection of synchronous breast lesions on initial diagnosis of breast cancer and evaluate factors affecting the PPV of BWBU according to varying clinicoimaging factors. A total of 75 patients who had synchronous lesions with pathologic confirmation at the initial diagnosis of breast cancer during January 2007 and December 2007 were included. The clinical factors of the patients were evaluated. One observer retrospectively reviewed the imaging studies of the index breast cancer lesion and the synchronous lesion. The PPV for additional biopsy was calculated for BWBU and various clinical and imaging factors affecting the PPV for BWBU were evaluated. The overall PPV for additional biopsy was 25.7% (18 of 70). The PPV for synchronous lesions detected both on mammography and BWBU, and detected only on BWBU, was 76.9% (10 of 13) and 14.3% (7 of 49), respectively. There was no clinical factor affecting the PPV for BWBU. Among the imaging factors, ipsilateral location of the synchronous lesion to the index lesion (P=0.06) showed a marginal statistically significant correlation with malignancy in the synchronous breast lesion. A mass with calcification on mammography presentation (P<0.01), presence of calcification among the ultrasonography findings (P<0.01), and high Breast Imaging Reporting and Data System final assessment (P<0.01) were imaging factors that were associated with malignancy in the additional synchronous lesion. BWBU can detect additional synchronous malignancy at the diagnosis of breast cancer with a relatively high PPV, especially when mammography findings are correlated with ultrasonographic findings.

  20. Analytical model for the photocurrent-voltage characteristics of bilayer MEH-PPV/TiO2 photovoltaic devices

    Directory of Open Access Journals (Sweden)

    Chen Chong

    2011-01-01

    Full Text Available Abstract The photocurrent in bilayer polymer photovoltaic cells is dominated by the exciton dissociation efficiency at donor/acceptor interface. An analytical model is developed for the photocurrent-voltage characteristics of the bilayer polymer/TiO2 photovoltaic cells. The model gives an analytical expression for the exciton dissociation efficiency at the interface, and explains the dependence of the photocurrent of the devices on the internal electric field, the polymer and TiO2 layer thicknesses. Bilayer polymer/TiO2 cells consisting of poly[2-methoxy-5-(2-ethylhexyloxy-1,4-phenylenevinylene] (MEH-PPV and TiO2, with different thicknesses of the polymer and TiO2 films, were prepared for experimental purposes. The experimental results for the prepared bilayer MEH-PPV/TiO2 cells under different conditions are satisfactorily fitted to the model. Results show that increasing TiO2 or the polymer layer in thickness will reduce the exciton dissociation efficiency in the device and further the photocurrent. It is found that the photocurrent is determined by the competition between the exciton dissociation and charge recombination at the donor/acceptor interface, and the increase in photocurrent under a higher incident light intensity is due to the increased exciton density rather than the increase in the exciton dissociation efficiency.

  1. Early 18F-FDG-PET/CT as a predictive marker for treatment response and survival in patients with metastatic colorectal cancer treated with irinotecan and cetuximab

    DEFF Research Database (Denmark)

    Skougaard, K; Nielsen, Dorte; Vittrup Jensen, Benny

    2016-01-01

    to RECIST 1.0. Results: By EORTC criteria, early metabolic response predicted partial metabolic response (PMR) with a high positive predictive value (PPV) of 0.875 and a high negative predictive value (NPV) of 0.714. Partial radiologic response was predicted with a low PPV of 0.368 but a high NPV of 1.......0. By PERCIST, PMR was predicted with a high PPV of 0.826 and an intermediate NPV of 0.667 and partial radiologic response was predicted with a low PPV of 0.5 but a high NPV of 1.0. Median OS was nearly the same with the two criteria sets; 14.1 months for early metabolic responders and 9.9 months for non......-responders using EORTC criteria and 13.5 and 10.1 months, respectively, using PERCIST. Conclusions: With both EORTC criteria and PERCIST, early reduction in FDG uptake was predictive of a later partial metabolic and partial radiologic response to treatment. It was also predictive of significantly longer survival...

  2. The relationship between the violet pigment PP-V production and intracellular ammonium level in Penicillium purpurogenum

    OpenAIRE

    Kojima, Ryo; Arai, Teppei; Matsufuji, Hiroshi; Kasumi, Takafumi; Watanabe, Taisuke; Ogihara, Jun

    2016-01-01

    Penicillium purpurogenum is the fungus that produces an azaphilone pigment. However, details about the pigment biosynthesis pathway are unknown. The violet pigment PP-V is the one of the main pigments biosynthesized by this fungus. This pigment contains an amino group in a pyran ring as its core structure. We focused on this pigment and examined the relationship between intracellular ammonium concentration and pigment production using glutamine as a nitrogen source. The intracellular ammonium...

  3. Non-contrast magnetic resonance imaging for bladder cancer: fused high b value diffusion-weighted imaging and T2-weighted imaging helps evaluate depth of invasion

    International Nuclear Information System (INIS)

    Lee, Minsu; Oh, Young Taik; Jung, Dae Chul; Park, Sung Yoon; Shin, Su-Jin; Cho, Nam Hoon; Choi, Young Deuk

    2017-01-01

    To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. (orig.)

  4. Non-contrast magnetic resonance imaging for bladder cancer: fused high b value diffusion-weighted imaging and T2-weighted imaging helps evaluate depth of invasion

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Minsu; Oh, Young Taik; Jung, Dae Chul; Park, Sung Yoon [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Shin, Su-Jin [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Hanyang University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Cho, Nam Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Choi, Young Deuk [Yonsei University College of Medicine, Department of Urology, Seoul (Korea, Republic of)

    2017-09-15

    To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. (orig.)

  5. Test of PPV and kVp magnitudes using a non invasive voltage test aiming an improvement on the measurement acquisition; Testes das grandezas PPV e kVp utilizando um medidor de tensao nao invasivo visando um aperfeicoamento na aquisicao de medidas

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, Rodrigo F. de; Dias, Daniel M.; Franciscatto, Priscila C.; Correa, Eduardo de L.; Vivolo, Vitor; Potiens, Maria da Penha A., E-mail: rodrigoifusp@yahoo.com.b, E-mail: dmdias@ipen.b, E-mail: pfranciscatto@yahoo.com.b, E-mail: edu1905@gmail.co, E-mail: vivolo@ipen.b, E-mail: mppalbu@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    In this work the measurements of PPV (Practical Peak Voltage) and kVp (Peak Voltage) were studied obtained by use of voltage non invasive, under different conditions, viewing an improvement on the acquisition measurements at the Instrument Calibration Laboratory of the IPEN, Sao Paulo, Brazil, for the implantation of the radiation quality required for the required calibrations for X radiation instruments

  6. Choosing a design to fit the situation: how to improve specificity and positive predictive values using Bayesian lot quality assurance sampling.

    Science.gov (United States)

    Olives, Casey; Pagano, Marcello

    2013-02-01

    Lot Quality Assurance Sampling (LQAS) is a provably useful tool for monitoring health programmes. Although LQAS ensures acceptable Producer and Consumer risks, the literature alleges that the method suffers from poor specificity and positive predictive values (PPVs). We suggest that poor LQAS performance is due, in part, to variation in the true underlying distribution. However, until now the role of the underlying distribution in expected performance has not been adequately examined. We present Bayesian-LQAS (B-LQAS), an approach to incorporating prior information into the choice of the LQAS sample size and decision rule, and explore its properties through a numerical study. Additionally, we analyse vaccination coverage data from UNICEF's State of the World's Children in 1968-1989 and 2008 to exemplify the performance of LQAS and B-LQAS. Results of our numerical study show that the choice of LQAS sample size and decision rule is sensitive to the distribution of prior information, as well as to individual beliefs about the importance of correct classification. Application of the B-LQAS approach to the UNICEF data improves specificity and PPV in both time periods (1968-1989 and 2008) with minimal reductions in sensitivity and negative predictive value. LQAS is shown to be a robust tool that is not necessarily prone to poor specificity and PPV as previously alleged. In situations where prior or historical data are available, B-LQAS can lead to improvements in expected performance.

  7. Correlation between photoconductivity in nanocrystalline titania and short circuit current transients in MEH-PPV/titania solar cells

    International Nuclear Information System (INIS)

    Xie, Z B; Henry, B M; Kirov, K R; Barkhouse, D A R; Burlakov, V M; Smith, H E; Grovenor, C R M; Assender, H E; Briggs, G A D; Kano, M; Tsukahara, Y

    2007-01-01

    We report the first experimental observation of a direct relationship between electron transport in different nanocrystalline TiO 2 thin films and the photovoltaic performance of TiO 2 /MEH-PPV composite solar cells made using these same TiO 2 films. We show that the transient behaviour in the composite solar cells under illumination can be explained by the transient photoconductivity performance of the TiO 2 layer

  8. Value of Fat-Suppressed Proton-Density-Weighted Turbo Spin-Echo Sequences in Detecting Meniscal Lesions: Comparison with Arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Schaefer, P.J.; Brossmann, J.; Frahm, C.; Hilgert, R.E.; Heller, M.; Jahnke, T.

    2006-01-01

    Purpose: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging (MRI) compared to arthroscopy in the detection of meniscal lesions. Material and Methods: In a prospective study, 31 knee joints were imaged on a 1.5T MR scanner before arthroscopy using the following sequences: (a) coronal and sagittal FS-PDw TSE (TR/TE: 4009/15 ms); (b) coronal T1w SE (TR/TE: 722/20 ms), and sagittal PDw TSE (TR/TE: 3800/15 ms). Other imaging parameters were: slice thickness 3 mm, FOV 160 mm, matrix 256x256. A total of 186 meniscal regions (62 menisci; anterior horn, body, posterior horn) were evaluated. Standard of reference was arthroscopy. Sensitivity, specificity, negative predictive value (npv), positive predictive value (ppv), and accuracy were calculated. Results: Arthroscopically, meniscal lesions were detected in 55/186 segments (35 medial and 20 lateral meniscal lesions). Sensitivity, specificity, npv, ppv, and accuracy for combination of coronal and sagittal FS PDw TSE were 91.4%, 98.3%, 95%, 97%, and 93.5% for the medial meniscus, and 90%, 98.6%, 97.3%, 94.7%, and 96.8% for the lateral. The results were comparable to the combination of coronal T1w SE and sagittal PDw TSE for the medial (88.6%, 98.3%, 93.4%, 96.9%, 91.4%) and the lateral (90%, 95.9%, 97.2%, 85.7%, 92.5%) meniscus. Conclusion: FS PDw TSE-MR sequences are an excellent alternative for the detection of meniscal lesions in comparison with diagnostic arthroscopy

  9. Added value of multiple versus single sessions of repetitive transcranial magnetic stimulation in predicting motor cortex stimulation efficacy for refractory neuropathic pain.

    Science.gov (United States)

    Pommier, Benjamin; Quesada, Charles; Fauchon, Camille; Nuti, Christophe; Vassal, François; Peyron, Roland

    2018-05-18

    OBJECTIVE Selection criteria for offering patients motor cortex stimulation (MCS) for refractory neuropathic pain are a critical topic of research. A single session of repetitive transcranial magnetic stimulation (rTMS) has been advocated for selecting MCS candidates, but it has a low negative predictive value. Here the authors investigated whether multiple rTMS sessions would more accurately predict MCS efficacy. METHODS Patients included in this longitudinal study could access MCS after at least four rTMS sessions performed 3-4 weeks apart. The positive (PPV) and negative (NPV) predictive values of the four rTMS sessions and the correlation between the analgesic effects of the two treatments were assessed. RESULTS Twelve MCS patients underwent an average of 15.9 rTMS sessions prior to surgery; nine of the patients were rTMS responders. Postoperative follow-up was 57.8 ± 15.6 months (mean ± standard deviation). Mean percentage of pain relief (%R) was 21% and 40% after the first and fourth rTMS sessions, respectively. The corresponding mean durations of pain relief were respectively 2.4 and 12.9 days. A cumulative effect of the rTMS sessions was observed on both %R and duration of pain relief (p < 0.01). The %R value obtained with MCS was 35% after 6 months and 43% at the last follow-up. Both the PPV and NPV of rTMS were 100% after the fourth rTMS session (p = 0.0045). A significant correlation was found between %R or duration of pain relief after the fourth rTMS session and %R at the last MCS follow-up (R 2 = 0.83, p = 0.0003). CONCLUSIONS Four rTMS sessions predicted MCS efficacy better than a single session in neuropathic pain patients. Taking into account the cumulative effects of rTMS, the authors found a high-level correlation between the analgesic effects of rTMS and MCS.

  10. Effects of inorganic nitrogen sources on the production of PP-V [(10Z)-12-carboxyl-monascorubramine] and the Expression of the nitrate assimilation gene cluster by Penicillium sp. AZ.

    Science.gov (United States)

    Arai, Teppei; Umemura, Sara; Ota, Tamaki; Ogihara, Jun; Kato, Jun; Kasumi, Takafumi

    2012-01-01

    A fungal strain, Penicillium sp. AZ, produced the azaphilone Monascus pigment homolog when cultured in a medium composed of soluble starch, ammonium nitrate, yeast extract, and citrate buffer, pH 5.0. One of the typical features of violet pigment PP-V [(10Z)-12-carboxyl-monascorubramine] is that pyranoid oxygen is replaced with nitrogen. In this study, we found that ammonia and nitrate nitrogen are available for PP-V biosynthesis, and that ammonia nitrogen was much more effective than nitrate nitrogen. Further, we isolated nitrate assimilation gene cluster, niaD, niiA, and crnA, and analyzed the expression of these genes. The expression levels of all these genes increased with sodium nitrate addition to the culture medium. The results obtained here strongly suggest that Penicillium sp. AZ produced PP-V using nitrate in the form of ammonium reduced from nitrate through a bioprocess assimilatory reaction.

  11. Role of different negative pressure values in the process of infected wounds treated by vacuum-assisted closure: an experimental study.

    Science.gov (United States)

    Zhou, Min; Yu, Aixi; Wu, Gang; Xia, Chengyan; Hu, Xiang; Qi, Baiwen

    2013-10-01

    Vacuum-assisted closure (VAC) device is widely used to treat infected wounds in clinical work. Although the effect of VAC with different negative pressure values is well established, whether different negative pressures could result in varying modulation of wound relative cytokines was not clear. We hypothesise that instead of the highest negative pressure value the suitable value for VAC is the one which is the most effective on regulating wound relative cytokines. Infected wounds created on pigs' back were used to investigate the effects of varying negative pressure values of VAC devices. Wounds were treated with VAC of different negative pressure values or moist gauze, which was set as control. The VAC foam, semiocclusive dresses and moist gauze were changed on days 3, 5, 7 and 9 after wounds were created. When changing dressings, tissues from wounds were harvested for bacteria count and histology examination including Masson's trichrome stain and immunohistochemistry for microvessels. Western blot was carried out to test the expression of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF). Results showed that on days 3 and 5 the number of bacteria in wounds treated by VAC with 75, 150, 225 and 300 mmHg was significantly decreased compared with that in wounds treated by gauze and 0 mmHg pressure value. However, there was no difference in wounds treated with negative pressure values of 75 , 150, 225 and 300 mmHg at any time spot. Immunohistochemistry showed that more microvessels were generated in wounds treated by VAC using 75 and 150 mmHg negative pressure comparing with that using 225 and 300 mmHg on days 3 and 5. However this difference vanished on days 7 and 9. Morphological evaluation by Masson's trichrome staining showed increased collagen deposition in VAC of 75 and 150 mmHg compared with that in VAC of 225 and 300 mmHg. Western blot showed that the expression of VEGF and bFGF significantly increased when the wounds

  12. Predictive value of antinuclear antibodies in autoimmune diseases classified by clinical criteria: Analytical study in a specialized health institute, one year follow-up

    Directory of Open Access Journals (Sweden)

    María Elena Soto

    2015-01-01

    Full Text Available Introduction: Determination of antinuclear antibodies (ANA by indirect immunofluorescence (IIF is usually the initial test for the diagnosis of systemic rheumatic diseases (SRD. Assigning predictive values to positive and negative results of the test is vital because lack of knowledge about ANAs and their usefulness in classification criteria of SRD leads to inappropriate use. Methods: Retrospective study, ANA tests requested by different specialties, correlation to patients' final diagnosis. Results: The prevalence of autoimmune disease was relatively low in our population yielding a low PPV and a high NPV for the ANA test. 40% of the patients had no clinical criteria applied prior to test. Coexistence of two or more autoimmune disorders affects prevalence and predictive values. Conclusion: Application of the test after careful evaluation for clinical criteria remarkably improves the positive likelihood ratio for the diagnosis.

  13. The Predictive Value of Scores Used in Intensive Care Unit for Burn Patients Prognostic.

    Science.gov (United States)

    Novac, M; Dragoescu, Alice; Stanculescu, Andreea; Duca, Lucica; Cernea, Daniela

    2014-01-01

    Statistical evaluation of the prognosis of burned patients based on the analysis of prognostic scores as quickly and easily obtainable that track the evolution of burned patient in ICU. Material / Methods: The prospective study included 92 patients were performed with severe burns on 35-67% body surface large area, aiming to establish a cut-off score for each studied and statistically significant prognostic parameter for assessing the risk of mortality. The control group was represented by 20 patients with burns on the body surface of 0.05) sex (male / female), but we had p cut-off. Quantification of variables by calculating the area under the ROC curve (AUC), sensitivity and sensitivity, positive predictive value (PPV) and negative predictive value (NPV), allowed a better appreciation of these prognostic scores. These systems applicable to the burned patient scores, making a cut-off of each index / mortality probability score, he can manifest usefulness in medical decision making process and strategy to reduce the risk of death in patients with severe burns.

  14. Human attitudes towards herpetofauna: the influence of folklore and negative values on the conservation of amphibians and reptiles in Portugal.

    Science.gov (United States)

    Ceríaco, Luis Mp

    2012-02-08

    Human values and folklore of wildlife strongly influence the effectiveness of conservation efforts. These values and folklore may also vary with certain demographic characteristics such as gender, age, or education. Reptiles and amphibians are among the least appreciated of vertebrates and are victims of many negative values and wrong ideas resulting from the direct interpretation of folklore. We try to demonstrate how these values and folklore can affect the way people relate to them and also the possible conservation impacts on these animals. A questionnaire survey distributed to 514 people in the district of Évora, Portugal, was used to obtain data regarding the hypothesis that the existence of wrong ideas and negative values contributes to the phenomenon of human-associated persecution of these animals. A structural equation model was specified in order to confirm the hypothesis about the possible relationships between the presence of perceptions and negative values about amphibians and reptiles and persecution and anti-conservation attitudes. Sociodemographic variables were also added. The results of the model suggest that the presence of folklore and negative values clearly predicts persecution and anti-conservation attitudes towards amphibians and reptiles. Also, the existence of folklore varies sociodemographically, but negative values concerning these animals are widespread in the population. With the use of structural equation models, this work is a contribution to the study of how certain ideas and values can directly influence human attitudes towards herpetofauna and how they can be a serious conservation issue.

  15. Positive predictive value of the infant respiratory distress syndrome diagnosis in the Danish National Patient Registry

    Directory of Open Access Journals (Sweden)

    Thygesen SK

    2013-08-01

    Full Text Available Sandra Kruchov Thygesen, Morten Olsen, Christian Fynbo ChristiansenDepartment of Clinical Epidemiology, Aarhus University Hospital, Aarhus, DenmarkBackground: Infant respiratory distress syndrome (IRDS is the most common respiratory disease in preterm infants, and is associated with considerable morbidity and mortality. Valid data on IRDS are important in clinical epidemiological research.Objectives: The objective of this study was to estimate the positive predictive value (PPV of the IRDS diagnosis registered in the population-based Danish National Patient Registry according to the International Classification of Diseases, 8th and 10th revisions.Methods: Between January 1, 1977 and December 31, 2008, we randomly selected three patients per year, 96 in total, who were registered with an IRDS diagnosis in the Danish National Patient Registry and living in the northern part of Denmark. Data on the infants included information on the presence of predefined clinical symptoms. We defined IRDS as the presence of at least two of four clinical symptoms (tachypnea, retractions or nasal flaring, grunting, and central cyanosis, which had to be present for more than 30 minutes. Using medical record review as the reference standard, we computed the positive predictive value of the registered IRDS diagnosis including 95% confidence intervals (CIs.Results: We located the medical record for 90 of the 96 patients (94%, and found an overall PPV of the IRDS diagnosis of 81% (95% CI 72%–88%. This did not vary substantially between primary and secondary diagnoses. The PPV was higher, at 89% (95% CI 80%–95%, for preterm infants born before 37 weeks of gestation.Conclusion: The PPV of the IRDS diagnosis in the Danish National Patient Registry is reasonable when compared with symptoms described in the corresponding medical records. The Danish National Patient Registry is a useful data source for studies of IRDS, particularly if restricted to preterm infants

  16. Human attitudes towards herpetofauna: The influence of folklore and negative values on the conservation of amphibians and reptiles in Portugal

    Science.gov (United States)

    2012-01-01

    Background Human values and folklore of wildlife strongly influence the effectiveness of conservation efforts. These values and folklore may also vary with certain demographic characteristics such as gender, age, or education. Reptiles and amphibians are among the least appreciated of vertebrates and are victims of many negative values and wrong ideas resulting from the direct interpretation of folklore. We try to demonstrate how these values and folklore can affect the way people relate to them and also the possible conservation impacts on these animals. Methods A questionnaire survey distributed to 514 people in the district of Évora, Portugal, was used to obtain data regarding the hypothesis that the existence of wrong ideas and negative values contributes to the phenomenon of human-associated persecution of these animals. A structural equation model was specified in order to confirm the hypothesis about the possible relationships between the presence of perceptions and negative values about amphibians and reptiles and persecution and anti-conservation attitudes. Sociodemographic variables were also added. Results The results of the model suggest that the presence of folklore and negative values clearly predicts persecution and anti-conservation attitudes towards amphibians and reptiles. Also, the existence of folklore varies sociodemographically, but negative values concerning these animals are widespread in the population. Conclusions With the use of structural equation models, this work is a contribution to the study of how certain ideas and values can directly influence human attitudes towards herpetofauna and how they can be a serious conservation issue. PMID:22316318

  17. Value of magnetic resonance imaging in prenatal diagnosis of placental accretism; Valor da ressonancia magnetica no diagnostico antenatal do acretismo placentario

    Energy Technology Data Exchange (ETDEWEB)

    Francisco, Viviane Vieira; Goldman, Suzan Menasce; Faria, Juliano; Szejnfeld, Jacob [Universidade Federal de Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: vieira_francisco@uol.com.br

    2006-12-15

    Purpose: to establish the main signs of placental accretism in magnetic resonance imaging (MRI) in patients with clinical suspicion and to estimate the benefit of this method. Methods: prospective transversal study with 15 patients suspected of placental accretism, referred between March 2003 and February 2006. Gestational age varied from 20 to 31 weeks. All patients underwent MRI to study the placenta and had previously done an ultrasonography. Material was sent to histological study. MRI was done on Magnetom Impact and Sonata Maestro Class Siemens{sup R}, with acquired sequences HASTE, TURBO SPIN in axial, sagittal, coronal planes and echo gradient (GE{sup R}), pre- and post-dynamic contrast in the best plan for acquisition. Images were analyzed by a team of two radiologists. Results: mean gestational age was 24.3 weeks. We studied seven placenta previa (47%), six anterior placentas (40%) and two posterior placentas (13%). Ultrasonography was positive in 80% of the placentas and MRI in 53%. However, echography had a low concordance with anatomic pathological studies by Kappa test (11%), revealing 75% of sensitivity, 14% of specificity, 50% as positive predictive value (PPV) and 33% as negative predictive value (NPV). MRI had an excellent concordance with anatomic pathological studies (0.86), showing 100% of sensitivity, 86% of specificity, 89% as PPV and 100% as NPV. Conclusions: MRI is useful for placental accretism diagnosis. The principal findings are transmural hyper-signal, the loss of continuity in myometrial wall in fast sequences and the identification of vessels invading myometrial layer in dynamic sequences. (author)

  18. The Effectiveness of a Collector Bag for Measurement of Post ...

    African Journals Online (AJOL)

    The aim of the study was to assess sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of collector bag and its correlation with hemoglobin (Hb) and hematocrit (Ht) variations. This study, carried on 100 women referred for admission to labor ward of Shohada hospital in Orumeyeh City, Iran, ...

  19. Magnetic resonance imaging in local staging of endometrial carcinoma: diagnostic performance, pitfalls, and literature review.

    Science.gov (United States)

    Zandrino, Franco; La Paglia, Ernesto; Musante, Francesco

    2010-01-01

    To assess the diagnostic accuracy of magnetic resonance imaging in local staging of endometrial carcinoma, and to review the results and pitfalls described in the literature. Thirty women with a histological diagnosis of endometrial carcinoma underwent magnetic resonance imaging. Unenhanced T2-weighted and dynamic contrast-enhanced Ti-weighted sequences were obtained. Hysterectomy and salpingo-oophorectomy was performed in all patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the detection of deep myometrial and cervical infiltration. For deep myometrial infiltration T2-weighted sequences reached a sensitivity of 85%, specificity of 76%, PPV of 73%, NVP of 87%, and accuracy of 80%, while contrast-enhanced scans reached a sensitivity of 90%, specificity of 80%, PPV of 82%, NPV of 89%, and accuracy of 85%. For cervical infiltration T2-weighted sequences reached a sensitivity of 75%, specificity of 88%, PPV of 50%, NPV of 96%, and accuracy of 87%, while contrast-enhanced scans reached a sensitivity of 100%, specificity of 94%, PPV of 75%, NPV of 100%, and accuracy of 95%. Unenhanced and dynamic gadolinium-enhanced magnetic resonance allows accurate assessment of myometrial and cervical infiltration. Information provided by magnetic resonance imaging can define prognosis and management.

  20. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Ming; Zhang, Qilin [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Wang, Meng [Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Soochow University, Division of Endocrinology, the Second Affiliated Hospital, Suzhou (China); Zhu, Jingjing [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Neuropathology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Yao, Zhenwei [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Radiology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Lu, Yun [Fudan University, Department of Nuclear Medicine, Huashan Hospital, Shanghai Medical College, Shanghai (China)

    2016-11-15

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  1. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    International Nuclear Information System (INIS)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei; Yao, Zhenwei; Lu, Yun

    2016-01-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  2. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly.

    Science.gov (United States)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yao, Zhenwei; Lu, Yun; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Yang, Yeping; Zhao, Yao; Wang, Yongfei

    2016-11-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly.

  3. Utility of urine lipoarabinomannan (LAM) in diagnosing tuberculosis and predicting mortality with and without HIV: prospective TB cohort from the Thailand Big City TB Research Network.

    Science.gov (United States)

    Suwanpimolkul, Gompol; Kawkitinarong, Kamon; Manosuthi, Weerawat; Sophonphan, Jiratchaya; Gatechompol, Sivaporn; Ohata, Pirapon June; Ubolyam, Sasiwimol; Iampornsin, Thatri; Katerattanakul, Pairaj; Avihingsanon, Anchalee; Ruxrungtham, Kiat

    2017-06-01

    To evaluate the applicability and accuracy of the urine lipoarabinomannan (LAM) test in tuberculosis (TB)/HIV co-infected patients and HIV-negative patients with disseminated TB. Frozen urine samples obtained at baseline from patients in the TB research cohort with proven culture-positive TB were selected for blinded urine LAM testing. One hundred and nine patients were categorized into four groups: (1) HIV-positive patients with TB; (2) HIV-negative patients with disseminated TB; (3) HIV-negative immunocompromised patients with TB; and (4) patients with diseases other than TB. The sensitivity of urine LAM testing for culture-positive TB, specificity of urine LAM testing for patients without TB, positive predictive value (PPV), and negative predictive value (NPV) were assessed. The sensitivity of the urine LAM test in group 1 patients with a CD4 T-cell count of >100, ≤100, and ≤50 cells/mm 3 was 38.5%, 40.6%, and 45%, respectively. The specificity and PPV of the urine LAM test were >80%. The sensitivity of the test was 20% in group 2 and 12.5% in group 3, and the specificity and PPV were 100% for both groups. A positive urine LAM test result was significantly associated with death. This promising diagnostic tool could increase the yield of TB diagnosis and may predict the mortality rate of TB infection, particularly in TB/HIV co-infected patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  4. Test of PPV and kVp magnitudes using a non invasive voltage test aiming an improvement on the measurement acquisition

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F. de; Dias, Daniel M.; Franciscatto, Priscila C.; Correa, Eduardo de L.; Vivolo, Vitor; Potiens, Maria da Penha A.

    2009-01-01

    In this work the measurements of PPV (Practical Peak Voltage) and kVp (Peak Voltage) were studied obtained by use of voltage non invasive, under different conditions, viewing an improvement on the acquisition measurements at the Instrument Calibration Laboratory of the IPEN, Sao Paulo, Brazil, for the implantation of the radiation quality required for the required calibrations for X radiation instruments

  5. Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis.

    Science.gov (United States)

    Zhou, Bang-Guo; Wang, Dan; Ren, Wei-Wei; Li, Xiao-Long; He, Ya-Ping; Liu, Bo-Ji; Wang, Qiao; Chen, Shi-Gao; Alizad, Azra; Xu, Hui-Xiong

    2017-08-01

    To evaluate the diagnostic performance of shear wave arrival time contour (SWATC) display for the diagnosis of breast lesions and to identify factors associated with the quality of shear wave propagation (QSWP) in breast lesions. This study included 277 pathologically confirmed breast lesions. Conventional B-mode ultrasound characteristics and shear wave elastography parameters were computed. Using the SWATC display, the QSWP of each lesion was assigned to a two-point scale: score 1 (low quality) and score 2 (high quality). Binary logistic regression analysis was performed to identify factors associated with QSWP. The area under the receiver operating characteristic curve (AUROC) for QSWP to differentiate benign from malignant lesions was 0.913, with a sensitivity of 91.9%, a specificity of 90.7%, a positive predictive value (PPV) of 74.0%, and a negative predictive value (NPV) of 97.5%. Compared with using the standard deviation of shear wave speed (SWS SD ) alone, SWS SD combined with QSWP increased the sensitivity from 75.8% to 93.5%, but decreased the specificity from 95.8% to 89.3% (P breast lesions.

  6. Performance improvement of MEH-PPV:PCBM solar cells using bathocuproine and bathophenanthroline as the buffer layers

    International Nuclear Information System (INIS)

    Liu Xiao Dong; Zhao Su-Ling; Xu Zheng; Zhang Fu-Jun; Zhang Tian-Hui; Gong Wei; Yan Guang; Kong Chao; Wang Yong-Sheng; Xu Xu-Rong

    2011-01-01

    In this work, bathocuproine (BCP) and bathophenanthroline (Bphen), commonly used in small-molecule organic solar cells (OSCs), are adopted as the buffer layers to improve the performance of the polymer solar cells (PSCs) based on poly(2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene) (MEH-PPV): [6,6]-phenyl-C 61 -butyric acid methyl ester (PCBM) bulk heterojunction. By inserting BCP or Bphen between the active layer and the top cathode, all the performance parameters are dramatically improved. The power conversion efficiency is increased by about 70% and 120% with 5-nm BCP and 12-nm Bphen layers, respectively, when compared with that of the devices without any buffer layer. The performance enhancement is attributed to BCP or Bphen (i) increasing the optical field, and hence the absorption in the active layer, (ii) effectively blocking the excitons generated in MEH-PPV from quenching at organic/aluminum (Al) interface due to the large band-gap of BCP or Bphen, which results in a significant reduction in series resistance (R s ), and (iii) preventing damage to the active layer during the metal deposition. Compared with the traditional device using LiF as the buffer layer, the BCP-based devices show a comparable efficiency, while the Bphen-based devices show a much larger efficiency. This is due to the higher electron mobility in Bphen than that in BCP, which facilitates the electron transport and extraction through the buffer layer to the cathode. (interdisciplinary physics and related areas of science and technology)

  7. [Total serum calcium and corrected calcium as severity predictors in acute pancreatitis].

    Science.gov (United States)

    Gutiérrez-Jiménez, A A; Castro-Jiménez, E; Lagunes-Córdoba, R

    2014-01-01

    To evaluate total serum calcium (TC) and albumin-corrected calcium (ACC) as prognostic severity factors in acute pancreatitis (AP). Ninety-six patients were included in the study. They were diagnosed with AP and admitted to the Hospital Regional de Veracruz within the time frame of January 2010 to December 2012. AP severity was determined through the updated Atlanta Classification (2013). TC and ACC values were measured in the first 24hours of admittance and the percentages of sensitivity (S), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR-) were calculated through ROC curves and contingency tables. In accordance with the updated Atlanta Classification, 70 patients presented with mild AP, 17 with moderately severe AP, and 9 with severe AP. Of the patient total, 61.5% were women, and 69.8% presented with biliary etiology. The maximum TC cut-off point was 7.5mg/dL, with values of S, 67%; Sp, 82%; PPV, 27%, and NPV, 96%. The maximum ACC cut-off point was 7.5mg/dL, with values of S, 67%; Sp, 90%; PPV, 40%; NPV, 96%. Both had values similar to those of the Ranson and APACHE II prognostic scales. TC and ACC, measured within the first 24hours, are useful severity predictors in acute pancreatitis, with sensitivity and predictive values comparable or superior to those of the conventional prognostic scales. Copyright © 2013 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  8. Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies

    Directory of Open Access Journals (Sweden)

    Malahiyo Rajabu

    2010-06-01

    Full Text Available Abstract Background The diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi. However, a more rapid, simpler, and cheaper diagnostic method would be very useful especially in developing countries. The Widal test is widely used in Africa but little information exists about its reliability. Methods We assessed the performance of the Widal tube agglutination test among febrile hospitalized Tanzanian children. We calculated the sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV of various anti-TH and -TO titers using culture-confirmed typhoid fever cases as the "true positives" and all other febrile children with blood culture negative for S. typhi as the "true negatives." Results We found that 16 (1% of 1,680 children had culture-proven typhoid fever. A single anti-TH titer of 1:80 and higher was the optimal indicator of typhoid fever. This had a sensitivity of 75%, specificity of 98%, NPV of 100%, but PPV was only 26%. We compared our main findings with those from previous studies. Conclusion Among febrile hospitalized Tanzanian children with a low prevalence of typhoid fever, a Widal titer of ≥ 1:80 performed well in terms of sensitivity, specificity, and NPV. However a test with improved PPV that is similarly easy to apply and cost-efficient is desirable.

  9. Magnetic Resonance Imaging Currently Fails to Fully Evaluate the Biceps-Labrum Complex and Bicipital Tunnel.

    Science.gov (United States)

    Taylor, Samuel A; Newman, Ashley M; Nguyen, Joseph; Fabricant, Peter D; Baret, Nikolas J; Shorey, Mary; Ramkumar, Prem; O'Brien, Stephen J

    2016-02-01

    To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for biceps-labrum complex (BLC) lesions, including the extra-articular bicipital tunnel. A retrospective review of 277 shoulders with chronic refractory BLC symptoms that underwent arthroscopic subdeltoid transfer of the long head of the biceps tendon (LHBT) to the conjoint tendon was conducted. Intraoperative lesions were categorized as "inside" (labral tears and dynamic LHBT incarceration), "junctional" (LHBT partial tears, LHBT subluxation, and biceps chondromalacia), or "bicipital tunnel" (extra-articular bicipital tunnel scar/stenosis, loose bodies, LHBT instability, and LHBT partial tears) based on anatomic location. Attending radiologist-generated MRI reports were graded dichotomously as positive or negative for biceps and labral damage and then compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for MRI with respect to intraoperative findings. With regard to inside lesions, MRI had an overall sensitivity, specificity, PPV, and NPV for labrum lesions of 77.3%, 68.2%, 57.3%, and 84.5% respectively. The sensitivity, specificity, PPV, and NPV of MRI for junctional lesions were 43.3%, 55.6%, 73.1%, and 26.0%, respectively. For the bicipital tunnel, MRI had a sensitivity, specificity, PPV, and NPV of 50.4%, 61.4%, 48.7%, and 63.0%, respectively. MRI was unreliable for ruling out BLC lesions among chronically symptomatic patients, including when the bicipital tunnel was affected. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    International Nuclear Information System (INIS)

    Amin, Mohammed Farghally; Youssef, Ahmed Omar

    2012-01-01

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy

  11. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Mohammed Farghally, E-mail: Mohammed_amin37@yahoo.com [Department of Radiodiagnosis ElMinya University, ElMinya High Road, ElMinya (Egypt); Youssef, Ahmed Omar [Department of Orthropedic Surgery El Minya University, ElMinya (Egypt)

    2012-09-15

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy.

  12. Predictive value of Borrelia burgdorferi IgG antibody levels in patients referred to a tertiary Lyme centre.

    Science.gov (United States)

    Zwerink, M; Zomer, T P; van Kooten, B; Blaauw, G; van Bemmel, T; van Hees, B C; Vermeeren, Y M; Landman, G W

    2018-03-01

    A two-step testing strategy is recommended in serological testing for Lyme borreliosis; positive and indeterminate enzyme-linked immunosorbent assay (ELISA) results are confirmed with immunoblots. Several ELISAs quantify the concentration of antibodies tested, however, no recommendation exists for an upper cut-off value at which an IgG ELISA is sufficient and the immunoblot can be omitted. The study objective was to determine at which IgG antibody level an immunoblot does not have any additional predictive value compared to ELISA results. Data of adult patients who visited a tertiary Lyme centre between 2008 and 2014 were analysed. Both an ELISA (Enzygnost Lyme link VlsE IgG) and immunoblot (recomLine blot Borrelia) were performed. Clinical data were extracted from the patient's digital medical record. Positive predictive values (PPVs) for either previous or active infection with Borrelia burgdorferi s.l. were calculated for different cut-off ELISA IgG antibody levels where the immunoblot was regarded as reference test. In total, 1454 patients were included. According to the two-step test strategy, 486 (33%), 69 (5%) and 899 (62%) patients had positive, indeterminate and negative Borrelia IgG serology, respectively. At IgG levels of 500 IU/ml and higher, all immunoblots were positive, resulting in a 100% PPV (95% CI: 97.0-100). At IgG levels of 200 IU/ml and higher, the PPV was 99.3% (95% CI: 97.4-99.8). In conclusion, at IgG levels of 200 IU/ml and higher, an ELISA was sufficient to detect antibodies to Borrelia burgdorferi s.l. At those IgG levels, a confirmatory immunoblot may be omitted in patients referred to a tertiary Lyme centre. Before these results can be implemented in routine diagnosis of Lyme borreliosis, confirmation of the results is necessary in other patient populations and using other quantitative ELISAs and immunoblots. Copyright © 2017 Elsevier GmbH. All rights reserved.

  13. The iliac wing sign: An indicator of the presence of bone and/or soft-tissue injury of the pelvis and hips

    Energy Technology Data Exchange (ETDEWEB)

    Kakigi, Takahide, E-mail: t.a.kakigi@dance.ocn.ne.jp [Department of Radiology, Saiseikai Ibaraki Hospital, 2-1-45 Mitsukeyama, Ibaraki, Osaka 567-0035 (Japan); Hosono, Makoto, E-mail: hosono@med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, 377-2 Ohno-higashi, Osakasayama, Osaka 589-8511 (Japan); Shimono, Taro [Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585 (Japan); Hiraoka, Taizo; Nishimura, Kazumasa [Department of Radiology, Saiseikai Ibaraki Hospital, 2-1-45 Mitsukeyama, Ibaraki, Osaka 567-0035 (Japan)

    2012-09-15

    Purpose: To prospectively evaluate the feasibility of using the “iliac wing sign (IWS)” as an indicator of bone and/or soft-tissue injury of the pelvis and hips on magnetic resonance (MR) imaging. IWS means edema of the iliacus muscle attachment entering the iliac wing that is visualized as a linear high signal intensity on fat-suppressed T2-weighted MR images. Methods: Consecutive 106 patients who complained of hip pain were enrolled in this study. We evaluated the correlation between IWS and bone and/or soft-tissue injury of the pelvis and hips using Fisher's exact test. Further, performance parameters of sensitivity, specificity, accuracy, the positive predictive value (PPV), and negative predictive value (NPV) of IWS were calculated. Results: Thirty-eight of the 106 (36%) patients had bone and/or soft-tissue injury. Twenty-seven of these 38 (71%) patients with injury showed a positive IWS, while only 11 of 68 (16%) patients without injury showed a positive IWS (p < .0001). IWS, thus, yielded a sensitivity of 71%, specificity of 84%, accuracy of 79%, positive predictive value (PPV) of 71%, and negative predictive value (NPV) of 84%. Conclusion: In cases with a positive IWS, the careful interpretation of MR images is needed because injury presence is highly likely, as suggested by the relatively high sensitivity and PPV. IWS absence may mean a low probability of injury because of the high specificity and NPV.

  14. Current nonclinical testing paradigm enables safe entry to First-In-Human clinical trials: The IQ consortium nonclinical to clinical translational database.

    Science.gov (United States)

    Monticello, Thomas M; Jones, Thomas W; Dambach, Donna M; Potter, David M; Bolt, Michael W; Liu, Maggie; Keller, Douglas A; Hart, Timothy K; Kadambi, Vivek J

    2017-11-01

    The contribution of animal testing in drug development has been widely debated and challenged. An industry-wide nonclinical to clinical translational database was created to determine how safety assessments in animal models translate to First-In-Human clinical risk. The blinded database was composed of 182 molecules and contained animal toxicology data coupled with clinical observations from phase I human studies. Animal and clinical data were categorized by organ system and correlations determined. The 2×2 contingency table (true positive, false positive, true negative, false negative) was used for statistical analysis. Sensitivity was 48% with a 43% positive predictive value (PPV). The nonhuman primate had the strongest performance in predicting adverse effects, especially for gastrointestinal and nervous system categories. When the same target organ was identified in both the rodent and nonrodent, the PPV increased. Specificity was 84% with an 86% negative predictive value (NPV). The beagle dog had the strongest performance in predicting an absence of clinical adverse effects. If no target organ toxicity was observed in either test species, the NPV increased. While nonclinical studies can demonstrate great value in the PPV for certain species and organ categories, the NPV was the stronger predictive performance measure across test species and target organs indicating that an absence of toxicity in animal studies strongly predicts a similar outcome in the clinic. These results support the current regulatory paradigm of animal testing in supporting safe entry to clinical trials and provide context for emerging alternate models. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Measurement of Interobserver Disagreement: Correction of Cohen’s Kappa for Negative Values

    Directory of Open Access Journals (Sweden)

    Tarald O. Kvålseth

    2015-01-01

    Full Text Available As measures of interobserver agreement for both nominal and ordinal categories, Cohen’s kappa coefficients appear to be the most widely used with simple and meaningful interpretations. However, for negative coefficient values when (the probability of observed disagreement exceeds chance-expected disagreement, no fixed lower bounds exist for the kappa coefficients and their interpretations are no longer meaningful and may be entirely misleading. In this paper, alternative measures of disagreement (or negative agreement are proposed as simple corrections or modifications of Cohen’s kappa coefficients. The new coefficients have a fixed lower bound of −1 that can be attained irrespective of the marginal distributions. A coefficient is formulated for the case when the classification categories are nominal and a weighted coefficient is proposed for ordinal categories. Besides coefficients for the overall disagreement across categories, disagreement coefficients for individual categories are presented. Statistical inference procedures are developed and numerical examples are provided.

  16. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    Science.gov (United States)

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  17. Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions-Comparison to arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, Fritz K.W.; Schaefer, Philipp J.; Brossmann, Joachim; Frahm, Christian; Muhle, Claus; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas

    2006-01-01

    Objective: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging for the detection of anterior and posterior cruciate ligament lesions in comparison to arthroscopy. Materials and methods: In a prospective study 31 knee joints were imaged on a 1.5 T MR scanner (Vision[reg], Siemens, Erlangen) prior to arthroscopy using following sequences: (a) sagittal FS-PDw/T2w TSE (TR/TE: 4009/15/105 ms); (b) sagittal PDw/T2w TSE (TR/TE:3800/15/105 ms). Further imaging parameters: slice thickness 3 mm, FOV 160 mm, matrix 256 x 256. A total of 62 anterior and posterior cruciate ligaments (ACL/PCL) were evaluated, standard of reference was arthroscopy. Sensitivity, specificity, positive (ppv) and negative predictive value (npv) and accuracy were calculated. Results: Twenty-one cruciate ligament ruptures were detected in arthroscopy, 19 ACL- and 2 PCL-ruptures (on MRI 34/124, 25/62 ACL, 9/62 PCL lesions). For all four sequences in the 31 patients with arthroscopic correlation sensitivity, specificity, ppv, npv and accuracy were 86%, 98%, 95%, 93% and 94% for detection of tears, and 84%, 100%, 100%, 80% and 90% for ACL-ruptures respectively. The two PCL-ruptures were true positive in all sequences, one intact PCL was diagnosed as torn (false positive). Conclusions: Fat-suppressed PDw/T2w TSE-MR sequences are comparable to PDw TSE sequences for the detection of ACL/PCL-lesions

  18. An ecotoxic risk assessment of residue materials produced by the plasma pyrolysis/vitrification (PP/V) process.

    Science.gov (United States)

    Lapa, N; Santos, Oliveira J F; Camacho, S L; Circeo, L J

    2002-01-01

    Plasma is the fourth state of matter, following the three states of solid, liquid and gas. Experience has amply demonstrated that solids exposed to the oxygen-deficient plasma flame are converted to liquid, and liquid exposed to the same flame is converted to gas. A low amount of vitrified solid residue material usually remains at the end of this process. Plasma pyrolysis/vitrification (PP/V) has been demonstrated as a safe, efficient, cost-effective technology for the treatment of wastes, including hazardous wastes. Besides the low amounts of gaseous byproducts that PP/V produces, the solid vitrified residue presents a low leachability of pollutants. Studies have been performed in many countries in order to assess the leachability of chemical substances. But from the results of identified studies, none has reported results on the ecotoxicological properties of the leachates. The aim of this study was to contribute to the assessment of ecotoxic risk of four different vitrified materials. Vitrified samples of contaminated soils, municipal solid wastes, and incinerator bottom ashes were submitted to the European leaching pre-standard test number prEN 12457-2. The leachates were analyzed for 22 chemical parameters. The biological characterization comprised the assessment of bioluminescence inhibition of Photobacterium phosphoreum bacterium, growth inhibition of Pseudokirchneriella subcapitata algae and the germination inhibition of Lactuca sativa vegetable. The chemical and ecotoxicological results were analyzed according to the French proposal of Criteria on the Evaluation Methods of Waste Toxicity (CEMWT) and a Toxicity Classification System (TCS). The chemical and ecotoxicological results indicated a low leachability of pollutants and a low toxicity level of leachates. All samples studied were as below the TCS class 1 level (no significant toxicity observed) and as non-ecotoxic for CEMWT. Therefore, the environmental ecotoxic risk of the analyzed vitrified samples

  19. Comparison of One versus Two Fecal Immunochemical Tests in the Detection of Colorectal Neoplasia in a Population-Based Colorectal Cancer Screening Program

    Directory of Open Access Journals (Sweden)

    Sarvenaz Moosavi

    2016-01-01

    Full Text Available Objective. To determine the positive predictive value (PPV of two versus one abnormal FIT in the detection of colorectal neoplasia in a Canadian population. Methods. Three communities enrolled in a colorectal cancer (CRC screening pilot program from 01/2009 to 04/2013 using 2 FITs. Data collected included demographics, colonoscopy, pathology, and FIT results. Participants completed both FITs and had one positive FIT and colonoscopy. PPV of one versus two abnormal FITs was calculated using a weighted-generalized score statistic. A two-sided 5% significance level was used. Results. 1576 of 17,031 average-risk participants, 50–75 years old, had a positive FIT. Colonoscopy revealed 58 (3.7% cancers, 419 (31.6% high-risk polyps, and 374 (23.7% low-risk polyps as the most significant lesion. PPV of one versus two positive FITs for cancer, high-risk polyps, and any neoplasia were 1% versus 8%, 20% versus 40%, and 48% versus 67%, respectively (p value < 0.0001. When the first FIT was negative, the second positive FIT detected 7 CRCs and 98 high-risk polyps. Conclusions. PPV of two positive FITs is superior to one positive FIT for CRC and high-risk polyps. The added value of the second FIT was 12% of total CRCs and 23% of total high-risk polyps.

  20. Assessment of real-time PCR cycle threshold values in Microsporum canis culture-positive and culture-negative cats in an animal shelter: a field study.

    Science.gov (United States)

    Jacobson, Linda S; McIntyre, Lauren; Mykusz, Jenny

    2018-02-01

    Objectives Real-time PCR provides quantitative information, recorded as the cycle threshold (Ct) value, about the number of organisms detected in a diagnostic sample. The Ct value correlates with the number of copies of the target organism in an inversely proportional and exponential relationship. The aim of the study was to determine whether Ct values could be used to distinguish between culture-positive and culture-negative samples. Methods This was a retrospective analysis of Ct values from dermatophyte PCR results in cats with suspicious skin lesions or suspected exposure to dermatophytosis. Results One hundred and thirty-two samples were included. Using culture as the gold standard, 28 were true positives, 12 were false positives and 92 were true negatives. The area under the curve for the pretreatment time point was 96.8% (95% confidence interval [CI] 94.2-99.5) compared with 74.3% (95% CI 52.6-96.0) for pooled data during treatment. Before treatment, a Ct cut-off of value between culture-positive and culture-negative samples during treatment. Ct values prior to treatment differed significantly between the true-positive and false-positive groups ( P = 0.0056). There was a significant difference between the pretreatment and first and second negative culture time points ( P = 0.0002 and P values for true positives and true negatives, and for pre- and intra-treatment time points. Conclusions and relevance Ct values had limited usefulness for distinguishing between culture-positive and culture-negative cases when field study samples were analyzed. In addition, Ct values were less reliable than fungal culture for determining mycological cure.

  1. Clinical importance of technetium-99m-methoxyisobutylisonitrile (MIBI) scintigraphy in differentiated thyroid carcinoma patients with elevated thyroglobulin levels and negative I-131 scanning results

    International Nuclear Information System (INIS)

    Kuecuek, N.O.; Kulak, H.A.; Aras, G.

    2006-01-01

    The aim of this study was to evaluate the potential contribution of Tc-99m-MIBI scintigraphy to the follow-up of patients with differentiated thyroid carcinoma, who had elevated Tg levels and negative I-131 whole-body scan (WBS) results. In this retrospective study, we evaluated 28 patients with differentiated thyroid carcinoma, who had total or near total thyroidectomy followed by an ablative dose of I-131 at various time intervals (15 women, 13 men; mean age 43±17 years). All patients were treated with T4 suppression. After a mean follow-up period of 6.1 years (range 3-15) all patients were determined to have a high serum Tg concentrations (>2 ng/ml) and previous negative I-131 WBS results. All patients were examined for metastatic sites using Tc-99m-MIBI scan. Scans were visually evaluated for detecting lymph node metastases and/or local recurrence, lung metastases and skeletal metastases. Tc-99m-MIBI scan demonstrated lesions in 23 patients (83.3%). In five patients with negative Tc-99m-MIBI scan findings (FN results): Chest CT showed small-sized mediastinal LN metastases in 2 patients and lung metastases in another 2 patients (<1 cm); Neck CT showed small-sized cervical LN involvement in 1 patient. The sensitivity of detection for neck was 94.4%, for lung 63.6%, and for bone lesions 100%. For all scan sites taken together, the sensitivity of disease detection was 83.3%, the specificity was 50%, positive predictive value (PPV) was 96.2%, and finally negative predictive value (NPV) was 16.7%. We concluded that Tc-99m-MIBI scan should be considered as a supplementary scintigraphic method for the follow-up of patients with high serum Tg levels and negative I-131 WBS results, and it can help clinicians in making the decision to treat these patients. (author)

  2. Comparison of the HEART and TIMI Risk Scores for Suspected Acute Coronary Syndrome in the Emergency Department.

    Science.gov (United States)

    Sun, Benjamin C; Laurie, Amber; Fu, Rongwei; Ferencik, Maros; Shapiro, Michael; Lindsell, Christopher J; Diercks, Deborah; Hoekstra, James W; Hollander, Judd E; Kirk, J Douglas; Peacock, W Frank; Anantharaman, Venkataraman; Pollack, Charles V

    2016-03-01

    The emergency department evaluation for suspected acute coronary syndrome (ACS) is common, costly, and challenging. Risk scores may help standardize clinical care and screening for research studies. The Thrombolysis in Myocardial Infarction (TIMI) and HEART are two commonly cited risk scores. We tested the null hypothesis that the TIMI and HEART risk scores have equivalent test characteristics. We analyzed data from the Internet Tracking Registry of Acute Coronary Syndromes (i*trACS) from 9 EDs on patients with suspected ACS, 1999-2001. We excluded patients with an emergency department diagnosis consistent with ACS, or without sufficient data to calculate TIMI and HEART scores. The primary outcome was 30-day major adverse cardiovascular events, including all-cause death, acute myocardial infarction, and urgent revascularization. We describe test characteristics of the TIMI and HEART risk scores. The study cohort included 8255 patients with 508 (6.2%) 30-day major adverse cardiovascular events. Receiver operating curve and reclassification analyses favored HEART [c statistic: 0.753, 95% confidence interval (CI): 0.733-0.773; continuous net reclassification improvement: 0.608, 95% CI: 0.527-0.689] over TIMI (c statistic: 0.678, 95% CI: 0.655-0.702). A HEART score 0-3 [negative predictive value (NPV) 0.982, 95% CI: 0.978-0.986; positive predictive value (PPV) 0.103, 95% CI: 0.094-0.113; likelihood ratio (LR) positive 1.76; LR negative 0.28] demonstrates similar or superior NPV/PPV/LR compared with TIMI = 0 (NPV 0.978, 95% CI: 0.971-0.983; PPV 0.077, 95% CI: 0.071-0.084; LR positive 1.28; LR negative 0.35) and TIMI = 0-1 (NPV 0.963, 95% CI: 0.958-0.968; PPV 0.102, 95% CI: 0.092-0.113; LR positive 1.73; LR negative 0.58). The HEART score has better discrimination than TIMI and outperforms TIMI within previously published "low-risk" categories.

  3. Evaluation of a new rapid lateral flow chromatography test for the diagnosis of Helicobacter Pylori

    International Nuclear Information System (INIS)

    Kaklikkaya, N.; Dinc, U.; Dabanca, Pinar A.; Aydin, F.; Erturk, M.; Akdogan, Remzi A.; Ozgur, O.; Uzun, Dogan Y.; Gungor, E.; Arslan, M.; Cobanoglu, U.

    2006-01-01

    The rapid, simple and non-invasive diagnosis of Helicobacter pylori (H. pylori) infection is important in implementing chemotherapy in appropriate manner, and in assessing persistent H. pylori infection after eradication therapy. The Immuno Card STAT HpSA kit (Meridian Bioscience, Europe) is a lateral flow chromatography test which utilizes a monoclonal anti-H. pylori antibody. In this study, we investigated the usefulness of the ImmunoCard STAT HpSA test before and after eradication therapy on patients referred to undergo upper gastrointestinal endoscopy. Sixty-five consecutive patients who were referred to undergo upper gastrointestinal endoscopy at the Department of Gastroenterology, Karadeniz Technical University Medical School, Turkey between February and August 2005 were included in this study. The ImmunoCard STAT HpSA was compared with 4 invasive tests (histology, gram staining, rapid urease test, and culture). The reference method was defined as positive when 2 of the 4 invasive tests were positive. A negative H. pylori status was considered when all 4 tests present concordant negative results. Overall, the ImmunoCard STAT HpSA test had 77.8% sensitivity, 79.3% specificity, 82.4% positive predictive value (PPV) and 74.2% negative predictive value (NPV) in all patients. With regard to pre-treatment values, the sensitivity was 70.6%, specificity 70.6%, PPV 100% and NPV 100% while on post-treatment group the sensitivity was 84.2%, specificity 64.7%, PPV 72.7% and NPV 78.6%. Our results indicate that the ImmunoCard STAT HpSA test is a rapid, simple, and helpful procedure not only to determine H. pylori infection but also to assess the success of eradication therapy. (author)

  4. Reliability of Meat, Fish, Dairy, and Egg Intake Over a 33-Year Interval in Adventist Health Study 2

    Science.gov (United States)

    Singh, Pramil N.; Batech, Michael; Faed, Pegah; Jaceldo-Siegl, Karen; Martins, Marcia; Fraser, Gary E.

    2015-01-01

    We studied Adventist Health Study 2 (AHS-2) cohort members to determine the reliability of long-term recall of adult dietary intake that occurred 33 years ago. Establishing the reliability of these measures supports studies of how dietary exposure across the life course affects risk of cancer and other noncommunicable disease outcomes. Among 1816 AHS-2 cohort members, we conducted a statistical comparison of long-term recall of meat, fish, dairy, and eggs at AHS-2 baseline with their report of current diet 33 years before AHS-2 baseline at an age of 30–60 years. Major findings are as follows: 1) a high correlation for frequency of red meat (R = 0.71), poultry (R = 0.67), and fish (R = 0.60); lower correlations for dairy (R = 0.19) and eggs (R = 0.28); 2) good concordance for dichotomous measures of red meat [sensitivity: 0.70; specificity: 0.92; positive predictive value (PPV): 0.91], poultry (sensitivity: 0.76; specificity: 0.87; PPV: 0.83), fish (sensitivity: 0.61; specificity: 0.93; PPV: 0.89), dairy (sensitivity: 0.95; specificity: 0.57; PPV: 0.99), and eggs (sensitivity: 0.95; specificity: 0.41; PPV: 0.96); negative predictive value for dairy and eggs was poor. Among older AHS-2 cohort members, we found good reliability of recall of red meat, poultry, and fish intake that occurred 33 years earlier. PMID:25298211

  5. 56 . ORIGINAL ARTICLE

    African Journals Online (AJOL)

    User

    1 Department of Microbiology, College of Natural and Applied Sciences, ... The Clinotech TB Screen test, a 3rd generation multi-antigen rapid ... The positive and Negative Predictive Values (PPV and NPV) were 79.2% ... The study participants were recruited from TB ... from home the next day, and the second spot sample.

  6. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  7. Performance of Rapid Diagnostic Tests for Imported Malaria in Clinical Practice: Results of a National Multicenter Study

    Science.gov (United States)

    Houzé, Sandrine; Boutron, Isabelle; Marmorat, Anne; Dalichampt, Marie; Choquet, Christophe; Poilane, Isabelle; Godineau, Nadine; Le Guern, Anne-Sophie; Thellier, Marc; Broutier, Hélène; Fenneteau, Odile; Millet, Pascal; Dulucq, Stéphanie; Hubert, Véronique; Houzé, Pascal; Tubach, Florence; Le Bras, Jacques; Matheron, Sophie

    2013-01-01

    We compared the performance of four rapid diagnostic tests (RDTs) for imported malaria, and particularly Plasmodium falciparum infection, using thick and thin blood smears as the gold standard. All the tests are designed to detect at least one protein specific to P. falciparum ( Plasmodium histidine-rich protein 2 (PfHRP2) or Plasmodium LDH (PfLDH)) and one pan-Plasmodium protein (aldolase or Plasmodium LDH (pLDH)). 1,311 consecutive patients presenting to 9 French hospitals with suspected malaria were included in this prospective study between April 2006 and September 2008. Blood smears revealed malaria parasites in 374 cases (29%). For the diagnosis of P. falciparum infection, the three tests detecting PfHRP2 showed high and similar sensitivity (96%), positive predictive value (PPV) (90%) and negative predictive value (NPV) (98%). The PfLDH test showed lower sensitivity (83%) and NPV (80%), despite good PPV (98%). For the diagnosis of non-falciparum species, the PPV and NPV of tests targeting pLDH or aldolase were 94–99% and 52–64%, respectively. PfHRP2-based RDTs are thus an acceptable alternative to routine microscopy for diagnosing P. falciparum malaria. However, as malaria may be misdiagnosed with RDTs, all negative results must be confirmed by the reference diagnostic method when clinical, biological or other factors are highly suggestive of malaria. PMID:24098699

  8. Identification of Distant Metastatic Disease in Uterine Cervical and Endometrial Cancers with FDG PET/CT: Analysis from the ACRIN 6671/GOG 0233 Multicenter Trial.

    Science.gov (United States)

    Gee, Michael S; Atri, Mostafa; Bandos, Andriy I; Mannel, Robert S; Gold, Michael A; Lee, Susanna I

    2018-04-01

    Purpose To assess the accuracy of staging positron emission tomography (PET)/computed tomography (CT) in detecting distant metastasis in patients with local-regionally advanced cervical and high-risk endometrial cancer in the clinical trial by the American College of Radiology Imaging Network (ACRIN) and the Gynecology Oncology Group (GOG) (ACRIN 6671/GOG 0233) and to compare central and institutional reader performance. Materials and Methods In this prospective multicenter trial, PET/CT and clinical data were reviewed for patients enrolled in ACRIN 6671/GOG 0233. Two central readers, blinded to site read and reference standard, reviewed PET/CT images for distant metastasis. Central review was then compared with institutional point-of-care interpretation. Reference standard was pathologic and imaging follow-up. Test performance for central and site reviews of PET/CT images was calculated and receiver operating characteristic analysis was performed. Generalized estimating equations and nonparametric bootstrap procedure for clustered data were used to assess statistical significance. Results There were 153 patients with cervical cancer and 203 patients with endometrial cancer enrolled at 28 sites. Overall prevalence of distant metastasis was 13.7% (21 of 153) for cervical cancer and 11.8% (24 of 203) for endometrial cancer. Central reader PET/CT interpretation demonstrated sensitivity, specificity, positive predictive value (PPV), and negative predictive value of 54.8%, 97.7%, 79.3%, and 93.1% for cervical cancer metastasis versus 64.6%, 98.6%, 86.1%, and 95.4% for endometrial cancer, respectively. By comparison, local institutional review demonstrated sensitivity, specificity, PPV, and negative predictive value of 47.6%, 93.9%, 55.6%, and 91.9% for cervical cancer metastasis and 66.7%, 93.9%, 59.3%, and 95.5% for endometrial cancer, respectively. For central readers, the specificity and PPV of PET/CT detection of cervical and endometrial cancer metastases were all

  9. Predictive values of diagnostic codes for identifying serious hypocalcemia and dermatologic adverse events among women with postmenopausal osteoporosis in a commercial health plan database.

    Science.gov (United States)

    Wang, Florence T; Xue, Fei; Ding, Yan; Ng, Eva; Critchlow, Cathy W; Dore, David D

    2018-04-10

    Post-marketing safety studies of medicines often rely on administrative claims databases to identify adverse outcomes following drug exposure. Valid ascertainment of outcomes is essential for accurate results. We aim to quantify the validity of diagnostic codes for serious hypocalcemia and dermatologic adverse events from insurance claims data among women with postmenopausal osteoporosis (PMO). We identified potential cases of serious hypocalcemia and dermatologic events through ICD-9 diagnosis codes among women with PMO within claims from a large US healthcare insurer (June 2005-May 2010). A physician adjudicated potential hypocalcemic and dermatologic events identified from the primary position on emergency department (ED) or inpatient claims through medical record review. Positive predictive values (PPVs) and 95% confidence intervals (CIs) quantified the fraction of potential cases that were confirmed. Among 165,729 patients with PMO, medical charts were obtained for 40 of 55 (73%) potential hypocalcemia cases; 16 were confirmed (PPV 40%, 95% CI 25-57%). The PPV was higher for ED than inpatient claims (82 vs. 24%). Among 265 potential dermatologic events (primarily urticaria or rash), we obtained 184 (69%) charts and confirmed 128 (PPV 70%, 95% CI 62-76%). The PPV was higher for ED than inpatient claims (77 vs. 39%). Diagnostic codes for hypocalcemia and dermatologic events may be sufficient to identify events giving rise to emergency care, but are less accurate for identifying events within hospitalizations.

  10. 82Rb Cardiac PET in patients with known ischemic heart disease – a direct comparison with 15O-water Cardiac PET

    DEFF Research Database (Denmark)

    Hoff, Camilla Molich; Tolbod, Lars Poulsen; Harms, Hans

    2017-01-01

    for both tracers and the extraction correction by Lortie et al for 82Rb. Comparisons included 1) correlation of absolute MBF for 82Rb versus 15O-water, 2) standard clinical practice for 82Rb using assessment of static, gated and dynamic scans by 2 experienced physicians (consensus), 3) in-house established...... was false positive in seven and false negative in zero, yielding a sensitivity of 100%, specificity 64%, PPV 68 % and NPV 100%. Comparing stress MBF, 82Rb on the patient-level was false positive in one and false negative in five, yielding a sensitivity of 71%, specificity 95%, PPV 92% and NPV 81......%. On the vessel-level there were six false positive and 24 false negative, yielding a sensitivity of 51%, specificity 91%, PPV 81% and NPV 72%. Global CFR (patient-level) identified five false positive and 10 false negative with a sensitivity of 41%, specificity 77%, PPV 58% and NPV 63%. Conclusion Standard...

  11. Prognostic value of predischarge dobutamine stress echocardiography in chest pain patients with a negative cardiac troponin T

    NARCIS (Netherlands)

    Bholasingh, Radha; Cornel, Jan Hein; Kamp, Otto; van Straalen, Jan P.; Sanders, Gerard T.; Tijssen, Jan G. P.; Umans, Victor A. W. M.; Visser, Cees A.; de Winter, Robbert J.

    2003-01-01

    OBJECTIVES We prospectively studied the prognostic value of predischarge dobutamine stress echocardiography (I)SE) in low-risk chest pain patients with a normal or nondiagnostic electrocardiogram (ECG) and a negative serial troponin T. BACKGROUND Noninvasive stress testing is recommended before

  12. Evaluation of PCA3 and multiparametric MRI’s: collective benefits before deciding initial prostate biopsy for patients with PSA level between 3-10ng/mL

    Directory of Open Access Journals (Sweden)

    Sezgin Okcelik

    2016-06-01

    Full Text Available ABSTRACT Objective To analyze the contribution of multiparametric MRI and PCA3 assay, pre- decision of initial biopsy in PSA level between 3-10 ng/mL patients with normal digital rectal examination(DRE. Materials and Methods PSA level 3-10 ng/mL ,patients, with normal DRE results and no previous prostate biopsy history, were included in this study. Each patient underwent multiparametric MRI one week before biopsy. Urine sample taking for PCA3 examination preceded the biopsy. Systematic and targeted biopsies were conducted. Patients with high PSA levels were seperated into two groups as: high PCA3 scored and low PCA3 scored. Then each group was divided into two sub-groups as: MRI lesion positive and negative. Tumor incidence, positive predictive values(PPV and negative predictive values(NPV were calculated. Results 53 patients were included between February 2013 and March 2014.Mean age 61.22 ± 1.06. Mean PSA value 5.13 ± 0.19 ng / mL. Mean PCA3 score 98.01 ± 23.13 and mean prostate size was 48.96 ± 2.67 grams. Fourty nine patients had both PCA3 score and multiparametric MRI. The PCA3’s PPV value was 58.33%. If multiparametric MRI lesions are added to high PCA3 scores , the PPV appears to elevate to 91.66%. NPV of PCA3 was 96%. NPV was 95% when there was no lesion in the multiparametric MRI with low PCA3 scores. Sensitivity was 91.66% , specificity was 95% respectively. Conclusion Adding multimetric MRI can also support biopsy decision for patients with high PCA3 value. When PCA3 value is low, patients can be survailled without any need to take a MRI.

  13. Correlation between conventional MR imaging combined with diffusion-weighted imaging and histopathologic findings in eyes primarily enucleated for advanced retinoblastoma. A retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Yanfen [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Xinhua Hospital, Shanghai (China); Shanxi Medical University, Department of Radiology, Shanxi Province Cancer Hospital, Taiyuan (China); Luo, Ran; Liu, Huanhuan; Zhang, Caiyuan; Zhang, Zhongyang; Wang, Dengbin [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Xinhua Hospital, Shanghai (China); Wang, Ruifen [Shanghai Jiao Tong University School of Medicine, Department of Pathology, Xinhua Hospital, Shanghai (China)

    2018-02-15

    To determine the diagnostic accuracy of conventional MRI in detecting tumour invasion of advanced intraocular retinoblastoma and to correlate ADC values with high-risk prognostic parameters. The sensitivities, specificities, positive predictive values (PPV), negative predictive values (NPV) and accuracies of MRI in detecting tumour-extent parameters of 63 retinoblastomas were determined. Furthermore, ADC values were correlated with high-risk prognostic parameters. MRI detected postlaminar optic nerve with a sensitivity of 73.3% (95% CI 44.9-92.2%) and a specificity of 89.6% (77.3-96.5%), while the specificity for choroidal invasion was only 31.8% (13.9-54.9%). Likewise, MRI failed to predicted early optic nerve invasion in terms of low sensitivity and PPV. In contrast, scleral and ciliary body invasion could be correctly excluded with high NPV. ADC values were significantly lower in patients with undifferentiated tumours, large tumour size, as with optic nerve and scleral invasion (all p < 0.05). However, no correlation was found between ADC values and the degree of choroidal or ciliary body infiltration. Additionally, ADC values were negatively correlated with Ki-67 index (r = -0.62, P = 0.002). Conventional MRI has some limitations in reliably predicting microscopic infiltration, with the diagnostic efficiency showing room for improvement, whereas ADC values correlated well with certain high-risk prognostic parameters for retinoblastoma. (orig.)

  14. Annual surveillance by CA125 and transvaginal ultrasound for ovarian cancer in both high-risk and population risk women is ineffective

    DEFF Research Database (Denmark)

    Woodward, E R; Sleightholme, H V; Considine, A M

    2007-01-01

    OBJECTIVE: To assess the efficacy of annual CA125 and transvaginal ultrasound (TVU) scan as surveillance for ovarian cancer. DESIGN: Retrospective audit. SETTING: NHS Trust. POPULATION: Three hundred and forty-one asymptomatic women enrolled for ovarian cancer screening: 179 were in a high...... and local cancer registry data. MAIN OUTCOME MEASURES: Ovarian cancers occurring in study population. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TVU, and CA125 as a screening tool for ovarian cancer. RESULTS: Four ovarian cancers and one endometrial...... cancer occurred. One ovarian cancer was detected at surveillance, three occurred in women who presented symptomatically between screenings. Thirty women underwent exploratory surgery because of abnormal findings at surveillance. Two women had cancer (PPV = 6.7%); one had ovarian cancer and the other...

  15. Evaluation of an automated spike-and-wave complex detection algorithm in the EEG from a rat model of absence epilepsy.

    Science.gov (United States)

    Bauquier, Sebastien H; Lai, Alan; Jiang, Jonathan L; Sui, Yi; Cook, Mark J

    2015-10-01

    The aim of this prospective blinded study was to evaluate an automated algorithm for spike-and-wave discharge (SWD) detection applied to EEGs from genetic absence epilepsy rats from Strasbourg (GAERS). Five GAERS underwent four sessions of 20-min EEG recording. Each EEG was manually analyzed for SWDs longer than one second by two investigators and automatically using an algorithm developed in MATLAB®. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the manual (reference) versus the automatic (test) methods. The results showed that the algorithm had specificity, sensitivity, PPV and NPV >94%, comparable to published methods that are based on analyzing EEG changes in the frequency domain. This provides a good alternative as a method designed to mimic human manual marking in the time domain.

  16. Staging of cervical endometrial carcinoma using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Vela, A. C.; Oleaga, L.; Cura del, J. L.; Grande, J.; Grande, D.

    1999-01-01

    To demonstrate the benefits of magnetic resonance imaging (MRI) for the staging of endometrial carcinoma and to compare the results of the spin echo (SE) sequence in T2 with the results of the pos gadolinium intravenous study. We have studied 51 women diagnosed with endometrial carcinoma by means of a D and C and confirmed surgically using T1 equipment. All of them have had SE T1 axial sequences, SE in protonic density (PD) and T'' on an axial and sagittal plane carried out on them and 32 cases were studied after the administration of gadolinium intravenously (i. V.). We have valued the depth of the myometrial infiltration and the cervical invasion. The positive predictive value (PPV) and the negative predictive value (VPV) of the MRI to value the deep infiltration of the endometrium were 87.9% and 77.8% respectively. In the 32 cases where we administered gadolinium we obtained a PPV of 90% and a NPV of 83.8%, in both the SE T2 study and the contrast study. In the diagnosis of the cervical invasion we have obtained PPV and NPV values of 75% and 88.1% respectively. In the group of the 32 cases that had the contrast agent administered, we have obtained the same results in both the series: PPV of 80% and NPV of 85.2%. We have found a high correlation index between the staging using MRI and pathological anatomy, especially in stages I and II of the IFGO (International Federation of Gynecology and Obstretics) classification. The use of gadolinium has not varied the results obtained with the SE T2 series. (Author) 18 refs

  17. Endometrial carcinoma: merit of magnetic resonance in pre-surgical staging; Carcinoma de endometrio: valor de la estadificacion prequirurgica por resonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, E.; Barrera, M. C.; Gervas, C.; Salvador, E.; Rivero, B. [Hospital Donostia. San sebastian (Spain); Sentis, M. [Corporacio Sanitaria Pare Tauli. Sabadell (Spain)

    2003-07-01

    To evaluate MR capacity in assessing deep myometrial and cervical infiltrations in cases of endometrial carcinoma. A series of 30 consecutively diagnosed endometrial cancer patients was pre-surgically evaluated by means of magnetic resonance (MR). TSE-T2 sequences with fat saturation and dynamic FFe sequence were used after gadolinium administration. A correlation with post-surgical histological stating was made. There were then determined sensitivity (S), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) for the deep myometrial infiltration and cervical invasion. Cases of overestimation and underestimation were analyzed. Values obtained for myometrium and cervix were, respectively, S of 67% and 63%, SP of 89% and 91%, PPV of 80% and 71% and NPV of 80% and 87%. Two cases each were over valued for myometrial infiltration and cervix: four cases and 3 cases, respectively, were undervalues. MR stating in cases of endometrial carcinoma is a highly reliable diagnostic technique, but it does present certain limitations. (Author) 19 refs.

  18. Endometrial carcinoma: merit of magnetic resonance in pre-surgical staging

    International Nuclear Information System (INIS)

    Fernandez, E.; Barrera, M. C.; Gervas, C.; Salvador, E.; Rivero, B.; Sentis, M.

    2003-01-01

    To evaluate MR capacity in assessing deep myometrial and cervical infiltrations in cases of endometrial carcinoma. A series of 30 consecutively diagnosed endometrial cancer patients was pre-surgically evaluated by means of magnetic resonance (MR). TSE-T2 sequences with fat saturation and dynamic FFe sequence were used after gadolinium administration. A correlation with post-surgical histological stating was made. There were then determined sensitivity (S), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) for the deep myometrial infiltration and cervical invasion. Cases of overestimation and underestimation were analyzed. Values obtained for myometrium and cervix were, respectively, S of 67% and 63%, SP of 89% and 91%, PPV of 80% and 71% and NPV of 80% and 87%. Two cases each were over valued for myometrial infiltration and cervix: four cases and 3 cases, respectively, were undervalues. MR stating in cases of endometrial carcinoma is a highly reliable diagnostic technique, but it does present certain limitations. (Author) 19 refs

  19. Initial accuracy assessment of the modified S-LANSS for the detection of neuropathic orofacial pain conditions.

    Science.gov (United States)

    Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin

    2017-01-01

    To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.

  20. T1 bright appendix sign to exclude acute appendicitis in pregnant women

    International Nuclear Information System (INIS)

    Shin, Ilah; An, Chansik; Lim, Joon Seok; Kim, Myeong-Jin; Chung, Yong Eun

    2017-01-01

    To evaluate the diagnostic value of the T1 bright appendix sign for the diagnosis of acute appendicitis in pregnant women. This retrospective study included 125 pregnant women with suspected appendicitis who underwent magnetic resonance (MR) imaging. The T1 bright appendix sign was defined as a high intensity signal filling more than half length of the appendix on T1-weighted imaging. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the T1 bright appendix sign for normal appendix identification were calculated in all patients and in those with borderline-sized appendices (6-7 mm). The T1 bright appendix sign was seen in 51% of patients with normal appendices, but only in 4.5% of patients with acute appendicitis. The overall sensitivity, specificity, PPV, and NPV of the T1 bright appendix sign for normal appendix diagnosis were 44.9%, 95.5%, 97.6%, and 30.0%, respectively. All four patients with borderline sized appendix with appendicitis showed negative T1 bright appendix sign. The T1 bright appendix sign is a specific finding for the diagnosis of a normal appendix in pregnant women with suspected acute appendicitis. (orig.)

  1. T1 bright appendix sign to exclude acute appendicitis in pregnant women

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ilah; An, Chansik; Lim, Joon Seok; Kim, Myeong-Jin; Chung, Yong Eun [Yonsei University College of Medicine, Department of Radiology, Research Institute of Radiological Science, Severance Hospital, 50-1 Yonsei-ro, Seodaemun-gu, Seoul (Korea, Republic of)

    2017-08-15

    To evaluate the diagnostic value of the T1 bright appendix sign for the diagnosis of acute appendicitis in pregnant women. This retrospective study included 125 pregnant women with suspected appendicitis who underwent magnetic resonance (MR) imaging. The T1 bright appendix sign was defined as a high intensity signal filling more than half length of the appendix on T1-weighted imaging. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the T1 bright appendix sign for normal appendix identification were calculated in all patients and in those with borderline-sized appendices (6-7 mm). The T1 bright appendix sign was seen in 51% of patients with normal appendices, but only in 4.5% of patients with acute appendicitis. The overall sensitivity, specificity, PPV, and NPV of the T1 bright appendix sign for normal appendix diagnosis were 44.9%, 95.5%, 97.6%, and 30.0%, respectively. All four patients with borderline sized appendix with appendicitis showed negative T1 bright appendix sign. The T1 bright appendix sign is a specific finding for the diagnosis of a normal appendix in pregnant women with suspected acute appendicitis. (orig.)

  2. Implementation of a new CT colonography service: 5 Year experience

    International Nuclear Information System (INIS)

    Lung, P.F.C.; Burling, D.; Kallarackel, L.; Muckian, J.; Ilangovan, R.; Gupta, A.; Marshall, M.; Shorvon, P.; Halligan, S.; Bhatnagar, G.; Bassett, P.; Taylor, S.A.

    2014-01-01

    Aim: To describe our experience using a 5 year audit of computed tomography colonography (CTC) practice and identify factors that influence diagnostic performance to guide implementation in other centres. Material and methods: Consecutive patients referred for CTC at a single institution over a 5 year period were identified, and reporting rates and positive predictive value (PPV) calculated for small polyps, large polyps, and colorectal cancer. Diagnostic performance was compared using the Chi-squared test, and trends over time were examined with logistic regression. The effect of faecal tagging and an intravenous spasmolytic were investigated using Fisher's exact test. Results: In total, 4355 CTC examinations were performed. Overall reporting rates and PPV were 17% and 92%, respectively. Negative predictive value (NPV) for cancer was 99.9%. A significant decrease in reporting rate (p < 0.001) was accompanied by an increase in PPV for small polyps (p = 0.02) following the introduction of faecal tagging. Adequacy rates for CTC improved over time (96% to 99%), with improved adequacy rates when using a spasmolytic, 98% versus 96% without. A significant difference in reporting rates, but not PPV, was found between radiologists. Conclusion: Accurate colonic investigation using CTC can be delivered safely to a high-risk patient population at a single centre. Faecal tagging and an intravenous spasmolytic improve diagnostic performance

  3. Expression of NS1 of PPV in E.coli%猪细小病毒NS1基因的原核表达

    Institute of Scientific and Technical Information of China (English)

    冉旭华; 闻晓波; 孟凡; 周恩民

    2007-01-01

    根据GenBank发表的猪细小病毒(porcine parvovirus, PPV)中国株基因序列设计引物,通过PCR方法扩增到了PPV LJL12株NS1全长基因,将其克隆到原核表达载pET30a(+)上,成功构建原核表达载体pET30a-NS1,将其转化到大肠杆菌BL21(DE3)感受态细胞.经IPTG诱导表达后,进行SDS-PAGE和Western blot分析.SDS-PAGE电泳显示NS1在大肠杆菌中得到成功表达,重组蛋白大小约为86 ku,与预期大小相符;Western blot分析表明,该蛋白能与PPV阳性血清发生特异性反应,证明该蛋白具有良好生物学活性.NS1在大肠杆菌中成功表达,具有免疫原性,可作为鉴别诊断抗原用于PPV的临床检测.

  4. Diagnostic accuracy of the Rivalta test for feline infectious peritonitis.

    Science.gov (United States)

    Fischer, Yvonne; Sauter-Louis, Carola; Hartmann, Katrin

    2012-12-01

    The Rivalta test has been used routinely in Europe to diagnose feline infectious peritonitis (FIP) in cats with effusions, but its diagnostic accuracy is uncertain. The objectives of this study were to calculate sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values of the Rivalta test for FIP and to identify correlations between a positive Rivalta test and variables measured in effusion fluid and peripheral blood. In this retrospective study, medical records of cats with effusions were reviewed, and cats with conclusive results for the Rivalta test were included. The prevalence of FIP in this population was determined, and sensitivity, specificity, and PPV and NPV of the Rivalta test were calculated. Variables measured in effusion fluid and peripheral blood were compared between cats that had positive or negative Rivalta tests using the Mann-Whitney U-test and multivariate analysis. Of 851 cats with effusions, 782 had conclusively positive or negative results for the Rivalta test. A definitive final diagnosis was made in 497 of these cats. Prevalence of FIP in cats with effusion and a conclusive Rivalta test result was 34.6%. The Rivalta test had a sensitivity of 91.3%, specificity of 65.5%, PPV of 58.4%, and NPV of 93.4% for the diagnosis of FIP. These values increased when cats with lymphoma or bacterial infections were excluded, or when only cats ≤ 2 years were considered. Increased effusion cholesterol concentration and specific gravity as well as decreased serum albumin:globulin ratio and hyperbilirubinemia were positively correlated with positive Rivalta test results. Sensitivity, specificity, and PPV of the Rivalta test for the diagnosis of FIP were lower than previously reported except when used in young cats. The components in effusions that lead to a positive Rivalta test remain unknown, but the positivity is not simply related to high total protein concentration. © 2012 American Society for Veterinary Clinical Pathology.

  5. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  6. Correlation between physical examination and intraoperative findings in shoulder disease treated by arthroscopy. Statistical analysis of 150 patients.

    Science.gov (United States)

    García Parra, P; Anaya Rojas, M; Jiménez Bravo, B; González Oria, M O; Lisbona Muñoz, M; Gil Álvarez, J J; Cano Luis, P

    2016-01-01

    Only a few clinical exploratory manoeuvres are truly discriminatory and useful in shoulder disease. The aim of this study is to correlate the physical examination results of the shoulder with the true diagnosis found by arthroscopy. A retrospective case series of 150 patients with the most common surgical conditions of the shoulder. Data were collected on the suspicion of each pathology, the physical examination of the patient, and the actual discovery of the disease during arthroscopic surgery. The Bankart examination manoeuvres of the lesion show the best results, with a 92.1% positive prediction value (PPV), a 99.1% negative predictive value (NPV), followed by the impingement syndrome, with a PPV of 94.4%, and total cuff rupture with a PPV of 92.3%.Exploration of the superior labrum anterior to posterior (SLAP) lesion had an NPV of 99.1%. Physical examination is sufficient to diagnose or rule out Bankart. A positive physical examination provides the complete rupture of the rotator cuff, and requires further studies. The patients suspected of subacromial syndrome only need an NMR if the physical tests are negative. The conclusions drawn from this work can have a significant impact on both cost savings (by reducing forward tests), and saving time in certain cases in which, after appropriate physical examination, surgery may be indicated without losing time in intermediate steps. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard: a retrospective study.

    Science.gov (United States)

    Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz

    2018-02-26

    Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.

  8. Pain on Functional Movement Screen Tests and Injury Risk.

    Science.gov (United States)

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle C; Anderson, Morgan K; North, William J; Jones, Bruce H

    2015-11-01

    The Functional Movement Screen (FMS) is a tool intended to evaluate limitations or asymmetries of movement to detect individuals at risk for exercise- and sports-related injury. The purpose was to determine the association and predictive value of specific FMS tests with injury risk in physically active men. Soldiers aged 18-57 years completed the FMS (n = 2,476). Demographic and fitness data were collected by survey. Medical record data for any, overuse, and traumatic injury 6 months after the assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated along with receiver operator characteristics to determine area under the curve (AUC). Risks, risk ratios, odds ratios (ORs), and 95% confidence intervals were calculated to assess injury risks. Multivariate logistic regression identified that pain on 5 of the 7 tests was associated with greater risk for any injury (OR = 1.50-3.51): deep squat, hurdle step, in-line lunge, trunk stability push-up, and rotary stability. However, FMS registered low sensitivity, PPV, and AUC for all 7 tests for the 3 injury types (2-24% sensitivity, 16-74% PPV, and 50-58% AUC). Although the presence of pain was associated with a higher risk of injury on 5 tests, a low sensitivity, PPV, and AUC were displayed. Therefore, caution is advised when implementing the FMS as a screening tool in an Army or similarly active population as it could lead to prevention and treatment resources being directed toward individuals who are not at greater risk for injury.

  9. [Application of a continual improvement approach to selecting diagnostic markers for acute pancreatitis in an emergency department].

    Science.gov (United States)

    Salinas, María; Flores, Emilio; López-Garrigós, Maite; Díaz, Elena; Esteban, Patricia; Leiva-Salinas, Carlos

    2017-01-01

    To apply a continual improvement model to develop an algorithm for ordering laboratory tests to diagnose acute pancreatitis in a hospital emergency department. Quasi-experimental study using the continual improvement model (plan, do, check, adjust cycles) in 2 consecutive phases in emergency patients: amylase and lipase results were used to diagnose acute pancreatitis in the first phase; in the second, only lipase level was first determined; amylase testing was then ordered only if the lipase level fell within a certain range. We collected demographic data, number amylase and lipase tests ordered and the findings, final diagnosis, and the results of a questionnaire to evaluate satisfaction with emergency care. The first phase included 517 patients, of whom 20 had acute pancreatitis. For amylase testing sensitivity was 0.70; specificity, 0.85; positive predictive value (PPV), 17; and negative predictive value (NPV), 0.31. For lipase testing these values were sensitivity, 0.85; specificity, 0.96; PPV, 21, and NPV, 0.16. When both tests were done, sensitivity was 0.85; specificity 0.99; PPV, 85; and NPV, 0.15. The second phase included data for 4815 patients, 118 of whom had acute pancreatitis. The measures of diagnostic yield for the new algorithm were sensitivity, 0.92; specificity, 0.98; PPV, 46; and NPV, 0.08]. This study demonstrates a process for developing a protocol to guide laboratory testing in acute pancreatitis in the hospital emergency department. The proposed sequence of testing for pancreatic enzyme levels can be effective for diagnosing acute pancreatitis in patients with abdominal pain.

  10. Comparison of initial and tertiary centre second opinion reads of multiparametric magnetic resonance imaging of the prostate prior to repeat biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Nienke L. [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology, Aachen (Germany); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Koo, Brendan C.; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Warren, Anne Y. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Pathology, Cambridge (United Kingdom); Doble, Andrew; Gnanapragasam, Vincent; Bratt, Ola; Kastner, Christof [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Urology, Cambridge (United Kingdom); Barrett, Tristan [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); University of Cambridge School of Clinical Medicine, Department of Radiology, Box 218, Cambridge (United Kingdom)

    2017-06-15

    To investigate the value of second-opinion evaluation of multiparametric prostate magnetic resonance imaging (MRI) by subspecialised uroradiologists at a tertiary centre for the detection of significant cancer in transperineal fusion prostate biopsy. Evaluation of prospectively acquired initial and second-opinion radiology reports of 158 patients who underwent MRI at regional hospitals prior to transperineal MR/untrasound fusion biopsy at a tertiary referral centre over a 3-year period. Gleason score (GS) 7-10 cancer, positive predictive value (PPV) and negative (NPV) predictive value (±95 % confidence intervals) were calculated and compared by Fisher's exact test. Disagreement between initial and tertiary centre second-opinion reports was observed in 54 % of cases (86/158). MRIs had a higher NPV for GS 7-10 in tertiary centre reads compared to initial reports (0.89 ± 0.08 vs 0.72 ± 0.16; p = 0.04), and a higher PPV in the target area for all cancer (0.61 ± 0.12 vs 0.28 ± 0.10; p = 0.01) and GS 7-10 cancer (0.43 ± 0.12 vs 0.2 3 ± 0.09; p = 0.02). For equivocal suspicion, the PPV for GS 7-10 was 0.12 ± 0.11 for tertiary centre and 0.11 ± 0.09 for initial reads; p = 1.00. Second readings of prostate MRI by subspecialised uroradiologists at a tertiary centre significantly improved both NPV and PPV. Reporter experience may help to reduce overcalling and avoid overtargeting of lesions. (orig.)

  11. The Value of Electronically Extracted Data for Auditing Outpatient Antimicrobial Prescribing.

    Science.gov (United States)

    Livorsi, Daniel J; Linn, Carrie M; Alexander, Bruce; Heintz, Brett H; Tubbs, Traviss A; Perencevich, Eli N

    2018-01-01

    OBJECTIVE The optimal approach to auditing outpatient antimicrobial prescribing has not been established. We assessed how different types of electronic data-including prescriptions, patient-visits, and International Classification of Disease, Tenth Revision (ICD-10) codes-could inform automated antimicrobial audits. DESIGN Outpatient visits during 2016 were retrospectively reviewed, including chart abstraction, if an antimicrobial was prescribed (cohort 1) or if the visit was associated with an infection-related ICD-10 code (cohort 2). Findings from cohorts 1 and 2 were compared. SETTING Primary care clinics and the emergency department (ED) at the Iowa City Veterans Affairs Medical Center. RESULTS In cohort 1, we reviewed 2,353 antimicrobial prescriptions across 52 providers. ICD-10 codes had limited sensitivity and positive predictive value (PPV) for validated cases of cystitis and pneumonia (sensitivity, 65.8%, 56.3%, respectively; PPV, 74.4%, 52.5%, respectively). The volume-adjusted antimicrobial prescribing rate was 13.6 per 100 ED visits and 7.5 per 100 primary care visits. In cohort 2, antimicrobials were not indicated in 474 of 851 visits (55.7%). The antimicrobial overtreatment rate was 48.8% for the ED and 59.7% for primary care. At the level of the individual prescriber, there was a positive correlation between a provider's volume-adjusted antimicrobial prescribing rate and the individualized rates of overtreatment in both the ED (r=0.72; P<.01) and the primary care setting (r=0.82; P=0.03). CONCLUSIONS In this single-center study, ICD-10 codes had limited sensitivity and PPV for 2 infections that typically require antimicrobials. Electronically extracted data on a provider's rate of volume-adjusted antimicrobial prescribing correlated with the frequency at which unnecessary antimicrobials were prescribed, but this may have been driven by outlier prescribers. Infect Control Hosp Epidemiol 2018;39:64-70.

  12. Double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours.

    Science.gov (United States)

    Burke, Elinor; Grobler, Mariana; Elderfield, Kay; Bond, Frances; Crocker, Matthew; Taylor, Rohan; Bridges, Leslie R

    2013-06-10

    Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard.

  13. Positive predictive value and impact of misdiagnosis of a heart failure diagnosis in administrative registers among patients admitted to a University Hospital cardiac care unit

    DEFF Research Database (Denmark)

    Mard, Shan; Nielsen, Finn Erland

    2010-01-01

    OBJECTIVE: To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF. DESIGN: The NRP was used to identify...

  14. Negative predictive value of ultrasound in predicting tumor-free margins in specimen sonography

    International Nuclear Information System (INIS)

    Naz, S.; Hafeez, S.; Hussain, Z.; Hilal, K.

    2017-01-01

    Objective: To evaluate the success of ultrasound in post-excision specimen visualization, and negative predictive value of ultrasound for estimation of tumor-free margins using histopathology as the gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: The Aga Khan University Hospital, Karachi, Pakistan, from May 2010 till January 2013. Methodology: Sonography of all breast nodules was done before and after exicision by two female radiologists with at least five years clinical experience. All surgeries were performed by the same referring breast surgeons. All nodules were non-palpable and had histopathology as well as specimen sonography performed at AKUH. Subjects were excluded, if histopathology was not available, post-procedure sonogram not done or done in another hospital and nodules that were not seen on ultrasound. After needle localization in 47 patients using ultrasound and in 7 patients using mammogram was done, sonogram was conducted in all 54 lesions. These were then assessed by ultrasound for detection of lesion and tumor-free margins in malignant lesion. Post-excision ultrasound was performed for the evaluation of lesion whether visualized or absent with localizing needle in situ, lesion dimensions, depth measurement between the superior margin of the lesion and its edge. Results: All 54 lesions were present on post-exicison scan, out of which 28 were documented as malignant and 26 as benign. Ultrasound declared all specimens as tumor-free. On histopathology, two lesions were documented as having tumor-positive margins and were proven to be invasive lobular carcinoma. Therefore, the negative predictive value of the specimen sonography for margin detection was 26/28 (92.8%). Conclusion: Ultrasound of the excised breast tumor specimen is a simple and reliable technique for confirmation of the tumor-free margins in non-palpable breast lesions. (author)

  15. Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

    International Nuclear Information System (INIS)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Picone, Dario; Anastasi, Andrea; Midiri, Massimo; Lagalla, Roberto

    2017-01-01

    The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US). Thirty-seven consecutive cancer patients (24 women and 13 men; age, 33 to 80 years; mean, 58.1 years) with geographic liver fatty deposition, but without any detectable focal liver lesion on greyscale US, underwent sulphur hexafluoride-enhanced US. Two readers reported by consensus the presence, size, and location of any detected lesion. All patients underwent magnetic resonance imaging (MRI) as a confirmatory study. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and accuracy were calculated. Seven focal liver lesions (size, 4 to 10 mm; mean, 6.1 mm) were detected in 4/37 patients (10.8%): four metastases (size, 5 to 10 mm; mean, 6.7 mm) were detected both by CEUS and MRI, with one hemangioma and two cysts (size range, 4 to 6 mm; mean, 5.3 mm) detected by MRI only. In 1/37 patients (2.7%), CEUS misdiagnosed geographic fatty change as three metastases. In 32/37 patients (86.5%), no lesions were detected. Sensitivity, specificity, PPV, NPV, and accuracy of CEUS were 100% (95% confidence Interval [CI], 1.000 to 1.000), 97.1% (95% CI, 0.914 to 1.027), 75%, 100%, and 97.3%, respectively. No statistically significant differences were found between CEUS and MRI in the detection of focal liver lesions (P=0.480), whereas both of them performed better than baseline US (P<0.001). CEUS improves the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale US

  16. Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

    Energy Technology Data Exchange (ETDEWEB)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Picone, Dario; Anastasi, Andrea; Midiri, Massimo; Lagalla, Roberto [Dept. of Radiology-Di.Bi.Med., University of Palermo, Palermo (Italy)

    2017-04-15

    The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US). Thirty-seven consecutive cancer patients (24 women and 13 men; age, 33 to 80 years; mean, 58.1 years) with geographic liver fatty deposition, but without any detectable focal liver lesion on greyscale US, underwent sulphur hexafluoride-enhanced US. Two readers reported by consensus the presence, size, and location of any detected lesion. All patients underwent magnetic resonance imaging (MRI) as a confirmatory study. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and accuracy were calculated. Seven focal liver lesions (size, 4 to 10 mm; mean, 6.1 mm) were detected in 4/37 patients (10.8%): four metastases (size, 5 to 10 mm; mean, 6.7 mm) were detected both by CEUS and MRI, with one hemangioma and two cysts (size range, 4 to 6 mm; mean, 5.3 mm) detected by MRI only. In 1/37 patients (2.7%), CEUS misdiagnosed geographic fatty change as three metastases. In 32/37 patients (86.5%), no lesions were detected. Sensitivity, specificity, PPV, NPV, and accuracy of CEUS were 100% (95% confidence Interval [CI], 1.000 to 1.000), 97.1% (95% CI, 0.914 to 1.027), 75%, 100%, and 97.3%, respectively. No statistically significant differences were found between CEUS and MRI in the detection of focal liver lesions (P=0.480), whereas both of them performed better than baseline US (P<0.001). CEUS improves the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale US.

  17. Infant and dyadic assessment in early community-based screening for autism spectrum disorder with the PREAUT grid.

    Directory of Open Access Journals (Sweden)

    Bertrand Olliac

    Full Text Available The need for early treatment of autism spectrum disorders (ASD necessitates early screening. Very few tools have been prospectively tested with infants of less than 12 months of age. The PREAUT grid is based on dyadic assessment through interaction and shared emotion and showed good metrics for predicting ASD in very-high-risk infants with West syndrome.We assessed the ability of the PREAUT grid to predict ASD in low-risk individuals by prospectively following and screening 12,179 infants with the PREAUT grid at four (PREAUT-4 and nine (PREAUT-9 months of age. A sample of 4,835 toddlers completed the Checklist for Autism in Toddlers (CHAT at 24 months (CHAT-24 of age. Children who were positive at one screening (N = 100 were proposed a clinical assessment (including the Children Autism Rating Scale, a Developmental Quotient, and an ICD-10-based clinical diagnosis if appropriate in the third year of life. A randomly selected sample of 1,100 individuals who were negative at all screenings was followed by the PMI team from three to five years of age to identify prospective false negative cases. The clinical outcome was available for 45% (N = 45 of positive children and 52.6% (N = 579 of negative children.Of the 100 children who screened positive, 45 received a diagnosis at follow-up. Among those receiving a diagnosis, 22 were healthy, 10 were diagnosed with ASD, seven with intellectual disability (ID, and six had another developmental disorder. Thus, 50% of infants positive at one screening subsequently received a neurodevelopmental diagnosis. The PREAUT grid scores were significantly associated with medium and high ASD risk status on the CHAT at 24 months (odds ratio of 12.1 (95%CI: 3.0-36.8, p < 0.001, at four months and 38.1 (95%CI: 3.65-220.3, p < 0.001, at nine months. Sensitivity (Se, specificity, negative predictive values, and positive predictive values (PPVs for PREAUT at four or nine months, and CHAT at 24 months, were similar [PREAUT-4

  18. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2015-10-01

    To assess the role of STIR, T2-weighted TSE and DWIBS sequences for detecting and characterizing breast lesions and to compare unenhanced (UE)-MRI results with contrast-enhanced (CE)-MRI and histological findings, having the latter as the reference standard. Two hundred eighty consecutive patients (age range, 27-73 years; mean age±standard deviation (SD), 48.8±9.8years) underwent MR examination with a diagnostic protocol including STIR, T2-weighted TSE, THRIVE and DWIBS sequences. Two radiologists blinded to both dynamic sequences and histological findings evaluated in consensus STIR, T2-weighted TSE and DWIBS sequences and after two weeks CE-MRI images searching for breast lesions. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and CE-MRI were calculated. UE-MRI results were also compared with CE- MRI. UE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 94%, 79%, 86%, 79% and 94%, respectively. CE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 98%, 83%, 90%, 84% and 98%, respectively. No statistically significant difference between UE-MRI and CE-MRI was found. Breast UE-MRI could represent an accurate diagnostic tool and a valid alternative to CE-MRI for evaluating breast lesions. STIR and DWIBS sequences allow to detect breast lesions while T2-weighted TSE sequences and ADC values could be useful for lesion characterization. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Comparison of pH and refractometry index with calcium concentrations in preparturient mammary gland secretions of mares.

    Science.gov (United States)

    Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Tsujimura, Koji; Nambo, Yasuo

    2013-01-15

    To test the usefulness of measuring pH and refractometry index, compared with measuring calcium carbonate concentration, of preparturient mammary gland secretions for predicting parturition in mares. Evaluation study. 27 pregnant Thoroughbred mares. Preparturient mammary gland secretion samples were obtained once or twice daily 10 days prior to foaling until parturition. The samples were analyzed for calcium carbonate concentration with a water hardness kit (151 samples), pH with pH test paper (222 samples), and refractometry index with a Brix refractometer (214 samples). The sensitivity, specificity, and positive and negative predictive values for each test were calculated for evaluation of predicting parturition. The PPV within 72 hours and the NPV within 24 hours for calcium carbonate concentration determination (standard value set to 400 μg/g) were 93.8% and 98.3%, respectively. The PPV within 72 hours and the NPV within 24 hours for the pH test (standard value set at 6.4) were 97.9% and 99.4%, respectively. The PPV within 72 hours and the NPV within 24 hours for the Brix test (standard value set to 20%) were 73.2% and 96.5%, respectively. Results suggested that the pH test with the standard value set at a pH of 6.4 would be useful in the management of preparturient mares by predicting when mares are not ready to foal. This was accomplished with equal effectiveness of measuring calcium carbonate concentration with a water hardness kit.

  20. Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review

    International Nuclear Information System (INIS)

    Nothacker, Monika; Duda, Volker; Hahn, Markus; Warm, Mathias; Degenhardt, Friedrich; Madjar, Helmut; Weinbrenner, Susanne; Albert, Ute-Susann

    2009-01-01

    Mammographic screening alone will miss a certain fraction of malignancies, as evidenced by retrospective reviews of mammograms following a subsequent screening. Mammographic breast density is a marker for increased breast cancer risk and is associated with a higher risk of interval breast cancer, i.e. cancer detected between screening tests. The purpose of this review is to estimate risks and benefits of supplemental breast ultrasound in women with negative mammographic screening with dense breast tissue. A systematic search and review of studies involving mammography and breast ultrasound for screening of breast cancer was conducted. The search was performed for the period 1/2000-8/2008 within the data source of PubMed, DARE, and Cochrane databases. Inclusion and exclusion criteria were determined prospectively, and the Oxford evidence classification system for diagnostic studies was used for evidence level. The parameters biopsy rate, positive predictive value (PPV) for biopsy, cancer yield for breast ultrasound alone, and carcinoma detection rate by breast density were extracted or constructed. The systematic search identified no randomized controlled trials or systematic reviews, six cohort studies of intermediate level of evidence (3b) were found. Only two of the studies included adequate follow-up of subjects with negative or benign findings. Supplemental breast ultrasound after negative mammographic screening permitted diagnosis of primarily invasive carcinomas in 0.32% of women in breast density type categories 2-4 of the American College of Radiology (ACR); mean tumor size for those identified was 9.9 mm, 90% with negative lymph node status. Most detected cancers occurred in mammographically dense breast ACR types 3 and 4. Biopsy rates were in the range 2.3%-4.7%, with PPV of 8.4-13.7% for those biopsied due to positive ultrasound, or about one third of the PPV of biopsies due to mammography. Limitations: The study populations included wide age ranges, and

  1. Evaluation of modified Alvarado scoring system and RIPASA scoring system as diagnostic tools of acute appendicitis.

    Science.gov (United States)

    Shuaib, Abdullah; Shuaib, Ali; Fakhra, Zainab; Marafi, Bader; Alsharaf, Khalid; Behbehani, Abdullah

    2017-01-01

    Acute appendicitis is the most common surgical condition presented in emergency departments worldwide. Clinical scoring systems, such as the Alvarado and modified Alvarado scoring systems, were developed with the goal of reducing the negative appendectomy rate to 5%-10%. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) scoring system was established in 2008 specifically for Asian populations. The aim of this study was to compare the modified Alvarado with the RIPASA scoring system in Kuwait population. This study included 180 patients who underwent appendectomies and were documented as having "acute appendicitis" or "abdominal pain" in the operating theatre logbook (unit B) from November 2014 to March 2016. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy, predicted negative appendectomy and receiver operating characteristic (ROC) curve of the modified Alvarado and RIPASA scoring systems were derived using SPSS statistical software. A total of 136 patients were included in this study according to our criteria. The cut-off threshold point of the modified Alvarado score was set at 7.0, which yielded a sensitivity of 82.8% and a specificity of 56%. The PPV was 89.3% and the NPV was 42.4%. The cut-off threshold point of the RIPASA score was set at 7.5, which yielded a 94.5% sensitivity and an 88% specificity. The PPV was 97.2% and the NPV was 78.5%. The predicted negative appendectomy rates were 10.7% and 2.2% for the modified Alvarado and RIPASA scoring systems, respectively. The negative appendectomy rate decreased significantly, from 18.4% to 10.7% for the modified Alvarado, and to 2.2% for the RIPASA scoring system, which was a significant difference (PAsian populations. It consists of 14 clinical parameters that can be obtained from a good patient history, clinical examination and laboratory investigations. The RIPASA scoring system is more accurate and specific than the modified Alvarado

  2. Predictive values of symptoms in relation to cancer diagnosis

    DEFF Research Database (Denmark)

    Krasnik, Ivan; Andersen, John Sahl

    a manual describing the symptoms that should engender reasonable suspicion of malignancy (“alarm symptoms”) to the general practitioner. Objectives: To investigate the evidence in the literature of the predictive value (PPV) placed on the”alarm symptoms” for colon cancer, breast cancer, prostate cancer...... years (6,6%-21,2%), but much lower in younger age groups. ”Change in bowel habits” and ”Significant general symptoms” are more uncertain (3,5%-8,5%). Breast cancer: ”Palpable suspect tumor” is well supported (8,1%-24%). The predictive value of ”Pitting of the skin”, ”Papil-areola eczema......Background/significance: Poorer prognosis for cancer patients in Denmark than in comparable countries has been shown and contributed to the introduction of accelerated diagnostic trajectories for patients suspicious for cancer in 2008. For all types of cancers the National Board of Health developed...

  3. Diagnostic value of 99mTc-pertechnetate salivary gland scintigraphy (SGS) in Sjoegren's syndrome (SS). Comparative study with symptomatic non Sjoegren patients and healthy controls

    International Nuclear Information System (INIS)

    Lobo, G.; Ladron de Guevara, D.; Zerboni, A.; Aguilera, S.

    2002-01-01

    The aim of this study was to describe SGS findings in patients with SS, and to compare them with non Sjoegren symptomatic and healthy control individual, estimating performance of SGS in SS diagnosis. Materials and Method: Fifty three control individual (average age: 53.7 yr, range: 27-83 yr) and 169 patients with subjective xerostomia underwent 99mTc-pertechnetate scintigraphy. The symptomatic group consisted of: 112 patients with Sjoegren's syndrome (average age: 53.7 yr, range:16-81 yr) according to modifying European Classification Criteria, 42 patients with fibromyalgia (FM)(average age:48.2 yr, range:19-76 yr) who presented non-specific chronic sialadenitis or normal labial biopsy, and 15 patients with keratoconjunctivitis sicca (KS) (average age: 40.9 yr, range:23-57 yr). SGS was performed following i.v. injection of 10 mCi 99mTc-pertechnetate, in dynamic acquisition of 60 15-sec frames, and giving lemon juice orally at 20 min. Irregular regions of interest (ROI) over salivary glands and brain for background assessment were drawn, building time-activity curves. SGS was classified according to visual intensity of gland tracer uptake and excretion before and after lemon and curve evaluation, in: normal (intensity of gland uptake fourfold background activity, ascending curve with fast and profound fall after lemon) , mild alteration (light decrease in gland uptake or excretion, with a normal curve shape), moderate alteration (evident uptake and excretion decrease with a median Mita curve) and severe alteration (very low or absent uptake, flat or slope curve). Scintigraphic findings were compared with diagnosis, calculating positive (PPV) and negative predictive value (NPV) for SS. Results: The results of SGS according to diagnosis are presented. SS group had higher incidence of severe alterations (p<0.001) than each of other clinics groups and lower proportion of mild alterations (p:0.008) and normal scans (p:0.005) than both control and KS patients. The KS

  4. A novel electroluminescent PPV copolymer and silsesquioxane nanocomposite film for the preparation of efficient PLED devices.

    Science.gov (United States)

    Venegoni, Ivan; Carniato, Fabio; Olivero, Francesco; Bisio, Chiara; Pira, Nello Li; Lambertini, Vito Guido; Marchese, Leonardo

    2012-11-02

    Polymer light-emitting diodes (PLEDs) have attracted growing interest in recent years for their potential use in displays and lighting fields. Nevertheless, PLED devices have some disadvantages in terms of low optoelectronic efficiency, high cost, short lifetimes and low thermal stability, which limit their final applications. Huge efforts have been made recently to improve the performances of these devices. The addition of inorganic or hybrid organic-inorganic nanoparticles to the light-emitting polymers, for example, allows their thermal stability and electroluminescent efficiency to be increased. Following this approach, novel PLED devices based on composite films of PPV-derivative copolymer (commercial name Super Yellow, SY) and octaisobutil POSS, were developed in this study. The device containing Super Yellow loaded with 1 wt% of POSS showed higher efficiency (ca. +30%) and improved lifetime in comparison to PLED prepared with the pure electroluminescent polymer. The PLED devices developed in this study are suitable candidates for automotive dashboards and, in general, for lighting applications.

  5. A surge of p-values between 0.041 and 0.049 in recent decades (but negative results are increasing rapidly too)

    Science.gov (United States)

    Dodou, Dimitra

    2015-01-01

    It is known that statistically significant (positive) results are more likely to be published than non-significant (negative) results. However, it has been unclear whether any increasing prevalence of positive results is stronger in the “softer” disciplines (social sciences) than in the “harder” disciplines (physical sciences), and whether the prevalence of negative results is decreasing over time. Using Scopus, we searched the abstracts of papers published between 1990 and 2013, and measured longitudinal trends of multiple expressions of positive versus negative results, including p-values between 0.041 and 0.049 versus p-values between 0.051 and 0.059, textual reporting of “significant difference” versus “no significant difference,” and the reporting of p 0.05. We found no support for a “hierarchy of sciences” with physical sciences at the top and social sciences at the bottom. However, we found large differences in reporting practices between disciplines, with p-values between 0.041 and 0.049 over 1990–2013 being 65.7 times more prevalent in the biological sciences than in the physical sciences. The p-values near the significance threshold of 0.05 on either side have both increased but with those p-values between 0.041 and 0.049 having increased to a greater extent (2013-to-1990 ratio of the percentage of papers = 10.3) than those between 0.051 and 0.059 (ratio = 3.6). Contradictorily, p 0.05 (ratios = 1.4 and 4.8, respectively), while the use of “significant difference” has shown only a modest increase compared to “no significant difference” (ratios = 1.5 and 1.1, respectively). We also compared reporting of significance in the United States, Asia, and Europe and found that the results are too inconsistent to draw conclusions on cross-cultural differences in significance reporting. We argue that the observed longitudinal trends are caused by negative factors, such as an increase of questionable research practices, but also by

  6. Preoperative Molecular Markers in Thyroid Nodules.

    Science.gov (United States)

    Sahli, Zeyad T; Smith, Philip W; Umbricht, Christopher B; Zeiger, Martha A

    2018-01-01

    The need for distinguishing benign from malignant thyroid nodules has led to the pursuit of differentiating molecular markers. The most common molecular tests in clinical use are Afirma ® Gene Expression Classifier (GEC) and Thyroseq ® V2. Despite the rapidly developing field of molecular markers, several limitations exist. These challenges include the recent introduction of the histopathological diagnosis "Non-Invasive Follicular Thyroid neoplasm with Papillary-like nuclear features", the correlation of genetic mutations within both benign and malignant pathologic diagnoses, the lack of follow-up of molecular marker negative nodules, and the cost-effectiveness of molecular markers. In this manuscript, we review the current published literature surrounding the diagnostic value of Afirma ® GEC and Thyroseq ® V2. Among Afirma ® GEC studies, sensitivity (Se), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV) ranged from 75 to 100%, 5 to 53%, 13 to 100%, and 20 to 100%, respectively. Among Thyroseq ® V2 studies, Se, Sp, PPV, and NPV ranged from 40 to 100%, 56 to 93%, 13 to 90%, and 48 to 97%, respectively. We also discuss current challenges to Afirma ® GEC and Thyroseq ® V2 utility and clinical application, and preview the future directions of these rapidly developing technologies.

  7. Morphology and performance of poly(2-methoxy-5-(20-ethyl-hexyloxy)-p-phenylenevinylene) (MEH-PPV) : (6,6)-phenyl-C61-butyric acid methyl ester (PCBM) based polymer solar cells

    NARCIS (Netherlands)

    Liu, L.J.; Bavel, van S.S.; Wen, S.P.; Yang, X.N.; Loos, J.

    2013-01-01

    Polymer solar cells were fabricated based on composite films of poly(2-methoxy-5-(2-ethyl-hexyloxy)-1,4-phenylenevinylene) (MEH-PPV):fullerene derivative (6,6)-phenyl-C61-butyric acid methyl ester (PCBM) with weight blend ratio of 1:3, 1:4 and 1:5, spin-coated from chloroform (CF), chlorobenzene

  8. Predicting Outcome in Comatose Patients: The Role of EEG Reactivity to Quantifiable Electrical Stimuli

    Directory of Open Access Journals (Sweden)

    Gang Liu

    2016-01-01

    Full Text Available Objective. To test the value of quantifiable electrical stimuli as a reliable method to assess electroencephalogram reactivity (EEG-R for the early prognostication of outcome in comatose patients. Methods. EEG was recorded in consecutive adults in coma after cardiopulmonary resuscitation (CPR or stroke. EEG-R to standard electrical stimuli was tested. Each patient received a 3-month follow-up by the Glasgow-Pittsburgh cerebral performance categories (CPC or modified Rankin scale (mRS score. Results. Twenty-two patients met the inclusion criteria. In the CPR group, 6 of 7 patients with EEG-R had good outcomes (positive predictive value (PPV, 85.7% and 4 of 5 patients without EEG-R had poor outcomes (negative predictive value (NPV, 80%. The sensitivity and specificity were 85.7% and 80%, respectively. In the stroke group, 6 of 7 patients with EEG-R had good outcomes (PPV, 85.7%; all of the 3 patients without EEG-R had poor outcomes (NPV, 100%. The sensitivity and specificity were 100% and 75%, respectively. Of all patients, the presence of EEG-R showed 92.3% sensitivity, 77.7% specificity, 85.7% PPV, and 87.5% NPV. Conclusion. EEG-R to quantifiable electrical stimuli might be a good positive predictive factor for the prognosis of outcome in comatose patients after CPR or stroke.

  9. More Accurate Oral Cancer Screening with Fewer Salivary Biomarkers

    Directory of Open Access Journals (Sweden)

    James Michael Menke

    2017-10-01

    Full Text Available Signal detection and Bayesian inferential tools were applied to salivary biomarkers to improve screening accuracy and efficiency in detecting oral squamous cell carcinoma (OSCC. Potential cancer biomarkers are identified by significant differences in assay concentrations, receiver operating characteristic areas under the curve (AUCs, sensitivity, and specificity. However, the end goal is to report to individual patients their risk of having disease given positive or negative test results. Likelihood ratios (LRs and Bayes factors (BFs estimate evidential support and compile biomarker information to optimize screening accuracy. In total, 26 of 77 biomarkers were mentioned as having been tested at least twice in 137 studies and published in 16 summary papers through 2014. Studies represented 10 212 OSCC and 25 645 healthy patients. The measure of biomarker and panel information value was number of biomarkers needed to approximate 100% positive predictive value (PPV. As few as 5 biomarkers could achieve nearly 100% PPV for a disease prevalence of 0.2% when biomarkers were ordered from highest to lowest LR. When sequentially interpreting biomarker tests, high specificity was more important than test sensitivity in achieving rapid convergence toward a high PPV. Biomarkers ranked from highest to lowest LR were more informative and easier to interpret than AUC or Youden index. The proposed method should be applied to more recently published biomarker data to test its screening value.

  10. Diagnostic value of transient dilatation of the left ventricle in negative dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Seo, Hiromi; Doi, Y.L.; Yonezawa, Yoshihiro; Chikamori, Taishiro; Yamada, Mitsutoshi; Ozawa, Toshio

    1994-01-01

    To evaluate the diagnostic value of a transient dilatation of the left ventricle during dipyridamole-thallium imaging (DTI) for detecting significant coronary artery disease (CAD) in patients with negative DTI results, 81 consecutive patients were studied. Twenty one patients (26%) had CAD and 60 patients had normal coronary anatomy (NCA). The initial/delayed ratio of the left ventricular dimension, which was measured as the distance between the 2 peaks of a count profile curve on a 45deg left anterior oblique planar image, was defined as the dilatation ratio (DR) of the left ventricle. Patients with CAD had a higher incidence of chest pain after dipyridamole infusion (35 vs 13%; p 1.03) when it was greater than the mean +2 standard deviations of the DR in NCA patients. Seventy-six percent of CAD patients had an abnormal DR. A stepwise discriminant analysis revealed that an abnormal DR alone had the same ability to predict CAD (sensitivity 76%, specificity 98%, chi-square 80.9, p 1.03) is a highly specific marker for detecting CAD, even in patients with negative dipyridamole-thallium imaging. (author)

  11. CT perfusion during delayed cerebral ischemia after subarachnoid hemorrhage: distinction between reversible ischemia and ischemia progressing to infarction

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, Charlotte H.P. [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, PO Box 85500, Utrecht, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Vos, Pieter C. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Schaaf, Irene C. van der; Velthuis, Birgitta K.; Dankbaar, Jan Willem [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Vergouwen, Mervyn D.I.; Rinkel, Gabriel J.E. [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, PO Box 85500, Utrecht, Utrecht (Netherlands)

    2015-09-15

    Delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (aSAH) can be reversible or progress to cerebral infarction. In patients with a deterioration clinically diagnosed as DCI, we investigated whether CT perfusion (CTP) can distinguish between reversible ischemia and ischemia progressing to cerebral infarction. From a prospectively collected series of aSAH patients, we included those with DCI, CTP on the day of clinical deterioration, and follow-up imaging. In qualitative CTP analyses (visual assessment), we calculated positive and negative predictive value (PPV and NPV) with 95 % confidence intervals (95%CI) of a perfusion deficit for infarction on follow-up imaging. In quantitative analyses, we compared perfusion values of the least perfused brain tissue between patients with and without infarction by using receiver-operator characteristic curves and calculated a threshold value with PPV and NPV for the perfusion parameter with the highest area under the curve. In qualitative analyses of 33 included patients, 15 of 17 patients (88 %) with and 6 of 16 patients (38 %) without infarction on follow-up imaging had a perfusion deficit during clinical deterioration (p = 0.002). Presence of a perfusion deficit had a PPV of 71 % (95%CI: 48-89 %) and NPV of 83 % (95%CI: 52-98 %) for infarction on follow-up. Quantitative analyses showed that an absolute minimal cerebral blood flow (CBF) threshold of 17.7 mL/100 g/min had a PPV of 63 % (95%CI: 41-81 %) and a NPV of 78 % (95%CI: 40-97 %) for infarction. CTP may differ between patients with DCI who develop infarction and those who do not. For this purpose, qualitative evaluation may perform marginally better than quantitative evaluation. (orig.)

  12. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    Science.gov (United States)

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  13. Studentized Continuous Wavelet Transform (t-CWT in the Analysis of Individual ERPs: Real and Simulated EEG Data

    Directory of Open Access Journals (Sweden)

    Ruben Gustav Leonhardt Real

    2014-09-01

    Full Text Available This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT as a method for the extraction and assessment of event-related brain potentials (ERP in data from a single subject. Sensitivity, specificity, positive (PPV and negative predictive values (NPV of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings.

  14. Double-labelling immunohistochemistry for MGMT and a “cocktail” of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours

    Science.gov (United States)

    2013-01-01

    Background Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Results Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Conclusions Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard. PMID:24252243

  15. Praise for regret: People value regret above other negative emotions

    OpenAIRE

    Saffrey, Colleen; Summerville, Amy; Roese, Neal J.

    2008-01-01

    What do people think about the emotion of regret? Recent demonstrations of the psychological benefits of regret have been framed against an assumption that most people find regret to be aversive, both when experienced but also when recalled later. Two studies explored lay evaluations of regret experiences, revealing them to be largely favorable rather than unfavorable. Study 1 demonstrated that regret, but not other negative emotions, was dominated by positive more than negative evaluations. ...

  16. First identification of porcine parvovirus 7 in China.

    Science.gov (United States)

    Xing, Xiulin; Zhou, Han; Tong, Ling; Chen, Yao; Sun, Yankuo; Wang, Heng; Zhang, Guihong

    2018-01-01

    Porcine parvovirus (PPV) are small, non-enveloped and single-stranded DNA viruses, taxonomically classifiable within the family Parvoviridae. Seven PPV genotypes (PPV1 to PPV7) have been identified to date. PPV7, the most recently discovered PPV genotype, was first reported in US pigs in 2016. To explore PPV7 status in Chinese pig populations a total of 64 serum samples collected from two commercial farms in Guangdong province in 2014 were analyzed. PPV7 DNA was detected in 32.8% (21/64) of tested samples. On the porcine circovirus type 2 (PCV2) positive farm, the prevalence rate of PPV7 was 65.5% (19/29) which was significantly higher than that on the PCV2 negative farm (2/35, 5.7%), indicating a possible association between PCV2 and PPV7 infections. The sequences of three PPV7 strains were determined. Phylogenetic analysis revealed that the identified PPV7 strains circulating in China shared 98.7%-99.7% nucleotide homology with the US strain. Further sequence comparison analysis indicated that GD-2014-2 and GD-2014-3 possess a consecutive 9-nt deletion in the VP gene. This is the first report of the existence of PPV7 in China and this finding will strengthen understanding of the epidemiology of porcine parvovirus in Chinese pigs.

  17. Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients

    International Nuclear Information System (INIS)

    Riegger, Carolin; Heusner, Till A.; Koeninger, Angela; Kimmig, Rainer; Hartung, Verena; Bockisch, Andreas; Otterbach, Friedrich; Forsting, Michael; Antoch, Gerald

    2012-01-01

    Background. FDG-PET/CT is increasingly being used for breast cancer staging. Its diagnostic accuracy in comparison to ultrasound as the standard non-invasive imaging modality for the evaluation of axillary lymph nodes has yet not been evaluated. Purpose. To retrospectively compare the diagnostic value of full-dose, intravenously contrast-enhanced FDG-PET/CT and ultrasound for the detection of lymph node metastases in breast cancer patients. Material and Methods. Ninety patients (one patient with a bilateral carcinoma) (89 women, one man; mean age, 55.5 ± 16.6 years) suffering from primary breast cancer underwent whole-body FDG-PET/CT and axillary ultrasound. The ipsilateral axillary fossa (n = 91) was evaluated for metastatic spread. The sensitivity, specificity, the positive predictive value (PPV), negative predictive value (NPV), and accuracy of both methods were calculated. The sensitivity and accuracy were statistically compared using the McNemar Test (P <0.05). Analyses were made on a patient basis. The number of patients with extra-axillary locoregional lymph node metastases exclusively detected by FDG-PET/CT was evaluated. For axillary lymph node metastases histopathology served as the reference standard. Results. The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases were 54%, 89%, 77%, 74%, and 75%, respectively. For ultrasound it was 38%, 78%, 54%, 65%, and 62%, respectively. FDG-PET/CT was significantly more accurate than ultrasound for the detection of axillary lymph node metastases (P = 0.019). There was no statistically significant difference between the sensitivity of both modalities (P = 0.0578). FDG-PET/CT detected extra-axillary locoregional lymph node metastases in seven patients (8%) that had not been detected by another imaging modality. Conclusion. Though more accurate compared to ultrasound for evaluating the axillary lymph node status FDG-PET/CT is only as sensitive as

  18. Facile and Scalable Synthesis Method for High-Quality Few-Layer Graphene through Solution-Based Exfoliation of Graphite.

    Science.gov (United States)

    Wee, Boon-Hong; Wu, Tong-Fei; Hong, Jong-Dal

    2017-02-08

    Here we describe a facile and scalable method for preparing defect-free graphene sheets exfoliated from graphite using the positively charged polyelectrolyte precursor poly(p-phenylenevinylene) (PPV-pre) as a stabilizer in an aqueous solution. The graphene exfoliated by PPV-pre was apparently stabilized in the solution as a form of graphene/PPV-pre (denoted to GPPV-pre), which remains in a homogeneous dispersion over a year. The thickness values of 300 selected 76% GPPV-pre flakes ranged from 1 to 10 nm, corresponding to between one and a few layers of graphene in the lateral dimensions of 1 to 2 μm. Furthermore, this approach was expected to yield a marked decrease in the density of defects in the electronic conjugation of graphene compared to that of graphene oxide (GO) obtained by Hummers' method. The positively charged GPPV-pre was employed to fabricate a poly(ethylene terephthalate) (PET) electrode layer-by-layer with negatively charged GO, yielding (GPPV-pre/GO) n film electrode. The PPV-pre and GO in the (GPPV-pre/GO) n films were simultaneously converted using hydroiodic acid vapor to fully conjugated PPV and reduced graphene oxide (RGO), respectively. The electrical conductivity of (GPPV/RGO) 23 multilayer films was 483 S/cm, about three times greater than that of the (PPV/RGO) 23 multilayer films (166 S/cm) comprising RGO (prepared by Hummers method). Furthermore, the superior electrical properties of GPPV were made evident, when comparing the capacitive performances of two supercapacitor systems; (polyaniline PANi/RGO) 30 /(GPPV/RGO) 23 /PET (volumetric capacitance = 216 F/cm 3 ; energy density = 19 mWh/cm 3 ; maximum power density = 498 W/cm 3 ) and (PANi/RGO) 30 /(PPV/RGO) 23 /PET (152 F/cm 3 ; 9 mWh/cm 3 ; 80 W/cm 3 ).

  19. Diagnostic value of glypican-3 in alpha fetoprotein negative ...

    African Journals Online (AJOL)

    EB

    2013-09-03

    Sep 3, 2013 ... School of Basic Medical Sciences, Capital Medical University, 100069, China. Abstract ... alpha fetoprotein(AFP) negative HCC and cirrhotic nodules is still difficult. Objectives: ..... Asia-Pacific Working Party on Prevention of.

  20. Screening method for Staphylococcus aureus identification in subclinical bovine mastitis from dairy farms

    Directory of Open Access Journals (Sweden)

    Natapol Pumipuntu

    2017-07-01

    Full Text Available Background: Staphylococcus aureus is one of the most important contagious bacteria causing subclinical bovine mastitis. This bacterial infection is commonly identified by determine the pathogen in bovine milk samples through conventional technique including coagulase test. However, this test has several disadvantages as low sensitivity, risk of biohazard, cost expensive, and limited preparation especially in local area. Aim: Aim of this study was to compare and assess the screening method, Mannitol fermentation test (Mannitol salt agar [MSA], and deoxyribonuclease (DNase test, for S. aureus identification in milk samples. Materials and Methods: A total of 224 subclinical bovine mastitis milk samples were collected from four provinces of Thailand and determined S. aureus using conventional method and also subjected to the screening test, MSA and DNase test. The sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV among both tests were analyzed and compared to the tube coagulase test (TCT, as reference method. Immunological test by latex agglutination and molecular assay by determined spa gene were also used to identify and differentiate S. aureus. Results: A total of 130 staphylococci were isolated by selective media, Gram-stain, and catalase test. The number of S. aureus which identified using TCT, MSA and DNase test were 32, 102, and 74 isolates, respectively. All TCT results were correlated to results of latex agglutination and spa gene which were 32 S. aureus. MSA showed 100% sensitivity, 28.57% specificity, 31.37% PPV, and 100% NPV, whereas DNase showed 53.13% sensitivity, 41.84% specificity, 22.97% PPV, and 73.21% NPV. DNase test showed higher specificity value than MSA but the test presented 26.79% false negative results whereas no false-negative result from MSA when comparing to TCT. Conclusion: MSA had a tendency to be a good preference for screening S. aureus because of its high sensitivity and

  1. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kitao, Shinichiro; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago City, Tottori (Japan); Kaetsu, Yasuhiro [Kakogawa Higashi Hospital, Department of Cardiology, Kakogawa (Japan); Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro [Tottori University, Division of Cardiology, Department of Molecular Medicine and Therapeutics, Faculty of Medicine, Yonago (Japan)

    2017-07-15

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. (orig.)

  2. Application of Mycobacterium Leprae-specific cellular and serological tests for the differential diagnosis of leprosy from confounding dermatoses.

    Science.gov (United States)

    Freitas, Aline Araújo; Hungria, Emerith Mayra; Costa, Maurício Barcelos; Sousa, Ana Lúcia Osório Maroccolo; Castilho, Mirian Lane Oliveira; Gonçalves, Heitor Sá; Pontes, Maria Araci Andrade; Duthie, Malcolm S; Stefani, Mariane Martins Araújo

    2016-10-01

    Mycobacterium leprae-specific serological and cell-mediated-immunity/CMI test were evaluated for the differential diagnosis of multibacillary/MB, and paucibacillary/PB leprosy from other dermatoses. Whole-blood assay/WBA/IFNγ stimulated with LID-1 antigen and ELISA tests for IgG to LID-1 and IgM to PGL-I were performed. WBA/LID-1/IFNγ production was observed in 72% PB, 11% MB leprosy, 38% dermatoses, 40% healthy endemic controls/EC. The receiver operating curve/ROC for WBA/LID-1 in PB versus other dermatoses showed 72.5% sensitivity, 61.5% specificity and an area-under-the-curve/AUC=0.75; 74% positive predictive value/PPV, 59% negative predictive value/NPV. Anti PGL-I serology was positive in 67% MB, 8% PB leprosy, 6% of other dermatoses; its sensitivity for MB=66%, specificity=93%, AUC=0.89; PPV=91%, NPV=72%. Anti-LID-1 serology was positive in 87% MB, 7% PB leprosy, all other participants were seronegative; 87.5% sensitivity for MB, 100% specificity, AUC=0.97; PPV=100%, NPV=88%. In highly endemic areas anti-LID-1/PGL-I serology and WBA/LID-1-represent useful tools for the differential diagnosis of leprosy from other confounding dermatoses. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Duplex criteria for determination of in-stent stenosis after angioplasty and stenting of the superficial femoral artery.

    Science.gov (United States)

    Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K

    2009-01-01

    Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.

  4. MRI characteristics of torn and untorn post-operative menisci

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Rosas, Humberto; Liu, Fang [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Williams, Adam [Radiology and Imaging Consultants, Colorado Springs (United States)

    2017-10-15

    To compare magnetic resonance imaging (MRI) characteristics of torn and untorn post-operative menisci. The study group consisted of 140 patients with 148 partially resected menisci who were evaluated with a repeat knee MRI examination and subsequent repeat arthroscopic knee surgery. Two musculoskeletal radiologists retrospectively assessed the following MRI characteristics of the post-operative meniscus: contour (smooth or irregular), T2 line through the meniscus (no line, intermediate signal line, intermediate-to-high signal line, and high fluid-like signal line), displaced meniscus fragment, and change in signal pattern through the meniscus compared with baseline MRI. Positive predictive values (PPV) and negative predictive values (NPV) were calculated using arthroscopy as the reference standard. All 36 post-operative menisci with no T2 line were untorn at surgery (100% NPV), whereas 46 of the 79 post-operative menisci with intermediate T2 line, 16 of the 18 post-operative menisci with intermediate-to-high T2 line, and 14 of the 15 post-operative menisci with high T2 line were torn at surgery (58.2%, 88.9%, and 93.3% PPV respectively). Additional MRI characteristics associated with torn post-operative meniscus at surgery were irregular meniscus contour (PPV 85.7%), displaced meniscus fragment (PPV 100%), and change in signal pattern through the meniscus (PPV 99.4%). Post-operative menisci with no T2 signal line were untorn at surgery. The most useful MRI characteristics for predicting torn post-operative menisci at surgery were change in signal pattern through the meniscus compared with baseline MRI, and displaced meniscus fragment followed by high T2 line through the meniscus, intermediate-to-high T2 line through the meniscus, and irregular meniscus contour. (orig.)

  5. MRI characteristics of torn and untorn post-operative menisci

    International Nuclear Information System (INIS)

    Kijowski, Richard; Rosas, Humberto; Liu, Fang; Williams, Adam

    2017-01-01

    To compare magnetic resonance imaging (MRI) characteristics of torn and untorn post-operative menisci. The study group consisted of 140 patients with 148 partially resected menisci who were evaluated with a repeat knee MRI examination and subsequent repeat arthroscopic knee surgery. Two musculoskeletal radiologists retrospectively assessed the following MRI characteristics of the post-operative meniscus: contour (smooth or irregular), T2 line through the meniscus (no line, intermediate signal line, intermediate-to-high signal line, and high fluid-like signal line), displaced meniscus fragment, and change in signal pattern through the meniscus compared with baseline MRI. Positive predictive values (PPV) and negative predictive values (NPV) were calculated using arthroscopy as the reference standard. All 36 post-operative menisci with no T2 line were untorn at surgery (100% NPV), whereas 46 of the 79 post-operative menisci with intermediate T2 line, 16 of the 18 post-operative menisci with intermediate-to-high T2 line, and 14 of the 15 post-operative menisci with high T2 line were torn at surgery (58.2%, 88.9%, and 93.3% PPV respectively). Additional MRI characteristics associated with torn post-operative meniscus at surgery were irregular meniscus contour (PPV 85.7%), displaced meniscus fragment (PPV 100%), and change in signal pattern through the meniscus (PPV 99.4%). Post-operative menisci with no T2 signal line were untorn at surgery. The most useful MRI characteristics for predicting torn post-operative menisci at surgery were change in signal pattern through the meniscus compared with baseline MRI, and displaced meniscus fragment followed by high T2 line through the meniscus, intermediate-to-high T2 line through the meniscus, and irregular meniscus contour. (orig.)

  6. The Prognostic Value of Lymph Nodes Dissection Number on Survival of Patients with Lymph Node-Negative Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Wu Song

    2014-01-01

    Full Text Available Objective. The study was designed to explore the prognostic value of examined lymph node (LN number on survival of gastric cancer patients without LN metastasis. Methods. Between August 1995 and January 2011, 300 patients who underwent gastrectomy with D2 lymphadenectomy for LN-negative gastric cancer were reviewed. Patients were assigned to various groups according to LN dissection number or tumor invasion depth. Some clinical outcomes, such as overall survival, operation time, length of stay, and postoperative complications, were compared among all groups. Results. The overall survival time of LN-negative GC patients was 50.2±30.5 months. Multivariate analysis indicated that LN dissection number (P30. Besides, it was not correlated with operation time, transfusion volume, length of postoperative stay, or postoperative complication incidence (P>0.05. Conclusions. The number of examined lymph nodes is an independent prognostic factor of survival for patients with lymph node-negative gastric cancer. Sufficient dissection of lymph nodes is recommended during surgery for such population.

  7. Direct MR Arthrography of the wrist in comparison with Arthroscopy: A prospective study on 125 patients

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Coblenz, G.; Froehner, S.; Meier, R.; Lanz, U.; Krimmer, H.

    2003-01-01

    Objective: In literature the diagnostic value of MRI for detecting lesions of the carpal ligaments and the TFCC is judged controversially. The aim of the following study is to determine the diagnostic accuracy of direct MR arthrography for depicting and staging of intraarticular lesions of the wrist. Material and methods: One day before undergoing arthroscopy, 125 patients suffering from wrist pain were examined with direct MR arthrography in a prospective and blinded study. A mixture of contrast medium (iodine-containing contrast medium and gadopentetate in relation 200:1) was injected into both radiocarpal and midcarpal joints. The following sequences were acquired on a 1.5T scanner: coronal T1-weighted SE, coronal fat-saturated T1-weighted SE, coronal T1-/T2*-DESS-3D, and sagittal T2*-weighted MEDIC. MRI results were compared with arthroscopic findings using statistical analysis (SEN=sensitivity, SPE=specificity, PPV=positive predictive value, NPV=negative predictive value, ACC=accuracy). Results: In comparison to arthroscopy as the accepted diagnostic gold standard, the following results were found for MR arthrography. Detection of TFCC lesions: SEN 97.1%, SPE 96.4%, PPV 97.1%, NPV 96.4%, ACC 96.8%. Detection of complete tears of the scapholunate ligament: SEN 91.7%, SPE 100%, PPV 100%, NPV 99.1%, ACC 99.2%. Detection of partial tears: SEN 62.5%, SPE 100%, PPV 100%, NPV 94.8%, ACC 95.2%. Detection of cartilage defects: SEN 84.2%, SPE 96.2%, PPV 80%, NPV 97.1%, ACC 94.4%. In total, only three lesions of the lunotriquetral ligament were present. Conclusion: Direct MR arthrographic imaging is well suited for detecting intraarticular lesions of the wrist. The presented diagnostic results of MR arthrography are superior to the results of unenhanced MRI reported in the literature. Direct MR arthrography as a reliable diagnostic tool is strongly recommended if lesions of the scapholunate ligament and the triangular fibrocartilage complex are suspected. In contrast, an

  8. Prognostic value of brain proton MR spectroscopy and diffusion tensor imaging in newborns with hypoxic-ischemic encephalopathy treated by brain cooling

    International Nuclear Information System (INIS)

    Ancora, G.; Testa, C.; Tonon, C.; Manners, D.N.; Gramegna, L.L.; Lodi, R.; Grandi, S.; Sbravati, F.; Savini, S.; Corvaglia, L.T.; Faldella, G.; Tani, G.; Malucelli, E.

    2013-01-01

    MRI, proton magnetic resonance spectroscopy ( 1 H-MRS), and diffusion tensor imaging (DTI) have been shown to be of great prognostic value in term newborns with moderate-severe hypoxic-ischemic encephalopathy (HIE). Currently, no data are available on 1 H-MRS and DTI performed in the subacute phase after hypothermic treatment. The aim of the present study was to assess their prognostic value in newborns affected by moderate-severe HIE and treated with selective brain cooling (BC). Twenty infants treated with BC underwent conventional MRI and 1 H-MRS at a mean (SD) age of 8.3 (2.8) days; 15 also underwent DTI. Peak area ratios of metabolites and DTI variables, namely mean diffusivity (MD), axial and radial diffusivity, and fractional anisotropy (FA), were calculated. Clinical outcome was monitored until 2 years of age. Adverse outcome was observed in 6/20 newborns. Both 1 H-MRS and DTI variables showed higher prognostic accuracy than conventional MRI. N-acetylaspartate/creatine at a basal ganglia localisation showed 100 % PPV and 93 % NPV for outcome. MD showed significantly decreased values in many regions of white and gray matter, axial diffusivity showed the best predictive value (PPV and NPV) in the genu of corpus callosum (100 and 91 %, respectively), and radial diffusivity was significantly decreased in fronto white matter (FWM) and fronto parietal (FP) WM. The decrement of FA showed the best AUC (0.94) in the FPWM. Selective BC in HIE neonates does not affect the early and accurate prognostic value of 1 H-MRS and DTI, which outperform conventional MRI. (orig.)

  9. Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Koung Mi; Choi, Sang Il; Chun, Eun Ju; Kim, Jeong A; Youn, Tae Jin; Choi, Dong Ju [Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2012-01-15

    We aimed to describe the imaging findings of multidetector CT coronary angiography (MDCTA) in cases of vasospastic angina (VA) and to determine the accuracy of MDCTA in the identification of VA as compared with invasive coronary angiography with an ergonovine provocation test (CAG with an EG test). Fifty-three patients with clinically suspected VA were enrolled in this study. Two radiologists analyzed the stenosis degree, presence or absence of plaque, plaque composition, and a remodeling index of the related-segment in CAG with an EG test, which were used as a gold standard. We evaluated the diagnostic performances of MDCTA by comparing the MDCTA findings with those of CAG with an EG test. Among the 25 patients with positive CAG with an EG test, all 12 patients with significant stenosis showed no definite plaque with the negative arterial remodeling. Of the six patients with insignificant stenosis, three (50%) had non-calcified plaque (NCP), two (33%) had mixed plaque, and one (17%) had calcified plaque. When the criteria for significant stenosis with negative remodeling but no definite evidence of plaque as a characteristic finding of MDCTA were used, results showed sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) of 48%, 100%, 100%, and 68%, respectively. Significant stenosis with negative remodeling, but no definite evidence of plaque, is the characteristic finding on MDCTA of VA. Cardiac MDCTA shows good diagnostic performance with high specificity and PPV as compared with CAG with an EG test.

  10. Quantitative analysis of Miller mobility index for the diagnosis of moderate to severe periodontitis - A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Chung-Ping Wu

    2018-03-01

    Full Text Available Background/purpose: We assessed the mobility of single-root teeth by using Miller's mobility index (MMI and to analyze the validity of MMI for the diagnosis of periodontitis. Materials and methods: A total of 30 patients were included and the Spearman correlation coefficient was used to assess the correlation between MMI, clinical attachment level (CAL, and probing depth (PD. The validity of MMI for the diagnosis of the severity of periodontitis was evaluated using the receiver operating characteristic (ROC curve, area under curve (AUC value, positive predictive value (PPV. Results: Strong correlations were observed between MMI and CAL (r = 0.92 and between MMI and PD (r = 0.76. When the CAL = 3–4 mm and CAL ≥5 mm groups were pooled together, the AUC value was 0.81. The AUC was 0.86 for diagnosis with MMI in the CAL ≥5 mm group. A PPV of 100% was achieved for all grades when MMI >1. When the teeth with PD ≥ 5 to <7 mm and PD ≥ 7 mm groups were pooled together, the AUC value for MMI was 0.80. The PPV was 98.8%, 99%, and 100% for MMI Grade 1, Grade 2, and Grade 3, respectively. When PD ≥ 7 mm was defined as severe periodontitis, the AUC value for MMI was 0.72. Conclusion: MMI may provide valuable information for the diagnosis of moderate and severe periodontitis when CAL is not obtainable during routine practice. Keywords: Miller's mobility index, Negative predictive value, Nonsurgical periodontal therapy, Positive predictive value, Receiver operating characteristic curve, Tooth mobility

  11. HPV-testing versus HPV-cytology co-testing to predict the outcome after conization.

    Science.gov (United States)

    Bruhn, Laerke Valsøe; Andersen, Sisse Josephine; Hariri, Jalil

    2018-06-01

    The purpose of this study was to determine the feasibility of human Papillomavirus (HPV) testing alone as a prognostic tool to predict recurrent disease within a three-year follow-up period after treatment for cervical intraepithelial neoplasia (CIN)2 + . Retrospectively, 128 women with histologically verified CIN2 + who had a conization performed at Southern Jutland Hospital in Denmark between 1 January 2013 and 31 December 2013 were included. Histology, cytology and HPV test results were obtained for a three-year follow-up period. 4.7% (6/128) of the cases developed recurrent disease during follow-up. Of the cases without free margins, recurrent dysplasia was detected normal in 10.4% (5/48), whereas in the group with free margins it was 1.3% (1/80). The post-conization HPV test was negative in 67.2% (86/128) and Pap smear normal in 93.7% (120/128). Combining resection margins, cytology and HPV had sensitivity for prediction of recurrent dysplasia of 100%. Specificity was 45.8%, positive predictive value (PPV) 8.5% and negative predictive value (NPV) 100%. Using HPV test alone as a predictor of recurrent dysplasia gave a sensitivity of 83.3%, specificity 69.7%, PPV 11.9% and NPV 98.8%. Combining resection margin and HPV test had a sensitivity of 100%, specificity 45.9%, PPV 8.3% and NPV 100%. HPV test at six months control post-conization gave an NPV of 98.8% and can be used as a solitary test to identify women at risk for recurrent disease three years after treatment for precursor lesions. Using both resection margin and HPV test had a sensitivity of 100% and NPV 100%. Adding cytology did not increase the predictive value. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  12. Diagnostic Accuracy of Dual-Source Computerized Tomography Coronary Angiography in Symptomatic Patients Presenting to a Referral Cardiovascular Center During Daily Clinical Practice

    International Nuclear Information System (INIS)

    Mahdavi, Arash; Mohammadzadeh, Ali; Joodi, Golsa; Tabatabaei, Mohammad Reza; Sheikholeslami, Farhad; Motevalli, Marzieh

    2016-01-01

    There are numerous studies that address the diagnostic value of dual-source computed tomography (DSCT) as an alternative to conventional coronary angiography (CCA). However, the benefit of application of DSCT in a real world clinical setting should be evaluated. To determine the diagnostic accuracy of DSCT technique compared with CCA as the gold standard method in detection of coronary artery stenosis among symptomatic patients who are presented to a referral cardiovascular center during daily clinical practice. Evaluating the medical records of a tertiary care referral cardiovascular center, 47 patients who had undergone DSCT and CCA, and also met the inclusion and exclusion criteria of the study were selected. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios (LRs) of the DSCT imaging technique were calculated. In total, 97.8% of the segments (628/642) could be visualized with diagnostic image quality via DSCT coronary angiography. The mean heart rate during DSCT was 69.2 ± 12.2 bpm (range: 39 - 83 bpm), and the mean Agatston score was 507.7 ± 590.5 (range: 0 - 2328). Per segment analysis of the findings revealed that the sensitivity, specificity, PPV, NPV, positive LR (PLR) and negative LR (NLR) of DSCT technique for evaluation of patients with coronary artery disease were 93.7%, 96.8%, 92.7%, 97.2%, 29.4, and 0.066, respectively. Also per vessel, analysis of the findings showed a sensitivity of 97.1%, a specificity of 94.0%, PPV of 95.3%, NPV of 96.3%, PLR of 16.1, and NLR of 0.030. Our results indicate that DSCT coronary angiography provides high diagnostic accuracy for the evaluation of CAD patients during daily routine practice of a referral cardiovascular setting

  13. MR evaluation of breast lesions obtained by diffusion-weighted imaging with background body signal suppression (DWIBS) and correlations with histological findings.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Capolongo, Arcangela; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-07-01

    Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions. 90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3)mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated. In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of >1.44 and 37 (70%) with ADC≤1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively. DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Value of repeat brain MRI in children with focal epilepsy and negative findings on initial MRI

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Tae Yeon; Kim, Ji Hye; Lee, Jee Hun; Yoo, So Young; Hwang, Sook Min; Lee, Mun Hyang [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    To evaluate the value of repeat brain magnetic resonance imaging (MRI) in identifying potential epileptogenic lesions in children with initial MRI-negative focal epilepsy. Our Institutional Review Board approved this retrospective study and waived the requirement for informed consent. During a 15-year period, 257 children (148 boys and 109 girls) with initial MRI-negative focal epilepsy were included. After re-evaluating both initial and repeat MRIs, positive results at repeat MRI were classified into potential epileptogenic lesions (malformation of cortical development and hippocampal sclerosis) and other abnormalities. Contributing factors for improved lesion conspicuity of the initially overlooked potential epileptogenic lesions were analyzed and classified into lesion factors and imaging factors. Repeat MRI was positive in 21% (55/257) and negative in 79% cases (202/257). Of the positive results, potential epileptogenic lesions comprised 49% (27/55) and other abnormalities comprised 11% of the cases (28/257). Potential epileptogenic lesions included focal cortical dysplasia (n = 11), hippocampal sclerosis (n = 10), polymicrogyria (n = 2), heterotopic gray matter (n = 2), microlissencephaly (n = 1), and cortical tumor (n = 1). Of these, seven patients underwent surgical resection. Contributing factors for new diagnoses were classified as imaging factors alone (n = 6), lesion factors alone (n = 2), both (n = 18), and neither (n = 1). Repeat MRI revealed positive results in 21% of the children with initial MRI-negative focal epilepsy, with 50% of the positive results considered as potential epileptogenic lesions. Enhanced MRI techniques or considering the chronological changes of lesions on MRI may improve the diagnostic yield for identification of potential epileptogenic lesions on repeat MRI.

  15. Value of repeat brain MRI in children with focal epilepsy and negative findings on initial MRI

    International Nuclear Information System (INIS)

    Jeon, Tae Yeon; Kim, Ji Hye; Lee, Jee Hun; Yoo, So Young; Hwang, Sook Min; Lee, Mun Hyang

    2017-01-01

    To evaluate the value of repeat brain magnetic resonance imaging (MRI) in identifying potential epileptogenic lesions in children with initial MRI-negative focal epilepsy. Our Institutional Review Board approved this retrospective study and waived the requirement for informed consent. During a 15-year period, 257 children (148 boys and 109 girls) with initial MRI-negative focal epilepsy were included. After re-evaluating both initial and repeat MRIs, positive results at repeat MRI were classified into potential epileptogenic lesions (malformation of cortical development and hippocampal sclerosis) and other abnormalities. Contributing factors for improved lesion conspicuity of the initially overlooked potential epileptogenic lesions were analyzed and classified into lesion factors and imaging factors. Repeat MRI was positive in 21% (55/257) and negative in 79% cases (202/257). Of the positive results, potential epileptogenic lesions comprised 49% (27/55) and other abnormalities comprised 11% of the cases (28/257). Potential epileptogenic lesions included focal cortical dysplasia (n = 11), hippocampal sclerosis (n = 10), polymicrogyria (n = 2), heterotopic gray matter (n = 2), microlissencephaly (n = 1), and cortical tumor (n = 1). Of these, seven patients underwent surgical resection. Contributing factors for new diagnoses were classified as imaging factors alone (n = 6), lesion factors alone (n = 2), both (n = 18), and neither (n = 1). Repeat MRI revealed positive results in 21% of the children with initial MRI-negative focal epilepsy, with 50% of the positive results considered as potential epileptogenic lesions. Enhanced MRI techniques or considering the chronological changes of lesions on MRI may improve the diagnostic yield for identification of potential epileptogenic lesions on repeat MRI

  16. Hyperbilirubinaemia: its utility in non-perforated appendicitis.

    Science.gov (United States)

    Sandstrom, Anna; Grieve, David A

    2017-07-01

    The diagnosis of acute appendicitis is made using clinical findings and investigations. Recent studies have suggested that serum bilirubin, a cheap and simple biochemical test, is a positive predictor in the diagnosis of appendiceal perforation and may be more specific than C-reactive protein (CRP) and white cell count (WCC). The aim of this study was to investigate the utility of the serum bilirubin level in patients with suspected acute but non-perforative appendicitis. A retrospective chart review of 213 patients who presented with suspected appendicitis in a 6-month period to Nambour General Hospital was performed. Serum bilirubin, WCC and CRP were recorded and analysed as to their utility in relation to the final diagnosis. A total of 196 patients underwent an appendicectomy and 41 of these were negative. The specificity of hyperbilirubinaemia for appendicitis overall was 0.83 with a positive predictive value (PPV) of 0.86, compared with CRP (specificity 0.40, PPV 0.75) and WCC (specificity 0.67, PPV 0.85). The area under the receiver operating characteristic curve for bilirubin was 0.6289 compared to 0.6171 for CRP and 0.7219 for WCC. A subgroup analysis of those with complicated appendicitis demonstrated a PPV for bilirubin of 0.66 compared to 0.58 for WCC and 0.34 for CRP in agreement with the literature. Subgroup analysis of hyperbilirubinaemia in simple appendicitis demonstrated a PPV of 0.81 compared to CRP (0.71) and WCC (0.82). Bilirubin had a higher specificity than CRP and WCC overall in patients with appendicitis. Hyperbilirubinaemia had a high PPV in patients with simple appendicitis. © 2015 Royal Australasian College of Surgeons.

  17. Comparison between arthroscopy and magnetic resonance studies of rupture of the anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Torregrosa, A.; Higueras, V.; Marti-Bonmati, L.; Casillas, C.; Sanfeliu, M.

    1999-01-01

    To compare the reliability of magnetic resonance (MR) in the diagnosis of rupture of the anterior cruciate ligament (ACL) with that of arthroscopy in a large series of patients. A series of 149 patients underwent arthroscopy and MR study of the knee. The condition of the ACL was classified as normal, partial rupture (increased signal in the ligament with integral hypointense fibers) or complete rupture (complete interruption or failure to visualize the ligament). The agreement (kappa), sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. MR images of ACL were normal in 114 of 116 normal cases; partial rupture was observed in 4 cases (versus 3 in arthroscopy) and complete rupture in 31 (versus 30 in arthroscopy). The agreement was excellent (kappa: 0.93; p < 0.001). For the diagnosis of normal ACL, the sensitivity of MR was 1, the specificity 0.98, the PPV 0.94 and the NPV 1. For the diagnosis of partial rupture, the sensitivity was 0.67, the specificity 0.98, the PPV 0.50 and the NPV 0.99. For complete rupture, the sensitivity was 0.97, the specificity 0.98, the PPV 0.94 and the NPV 0.99. The high sensitivity and specificity of MR observed in the diagnosis of integral ACL is somewhat reduced in cases of complete rupture and even lower in cases of partial rupture. It is important to differentiate the degree of rupture since the therapeutic management of the patient differs. (Author) 18 refs

  18. Muscle Weakness in the Empty and Full Can Tests Cannot Differentiate Rotator Cuff Tear from Cervical Spondylotic Amyotrophy: Pain Provocation is a Useful Finding.

    Science.gov (United States)

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Sakamoto, Yoshihiro; Tanaka, Yasuhito

    2017-01-01

    Rotator cuff tears and cervical spondylotic amyotrophy (CSA) are often confused as the main symptom in those with difficulty in shoulder elevation. Empty and full can tests are frequently used for the clinical diagnosis of rotator cuff tears. The aim of the present study was to investigate whether the empty and full can test results can help differentiate rotator cuff tears from CSA. Twenty-seven consecutive patients with rotator cuff tears and 25 with CSA were enrolled. We prospectively performed empty and full can tests in patients with rotator cuff tears and CSA. The following signs were considered positive: (a) muscle weakness during the empty can test, (b) muscle weakness during the full can test, (c) pain provocation during the empty can test, and (d) pain provocation during the full can test. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of rotator cuff tears for each positive finding. The sensitivity and specificity of each index were as follows (sensitivity, specificity, PPV, NPV): (a) 77.8%, 0%, 45.7%, 0%; (b) 66.7%, 4.0%, 42.9%, 10.0%; (c) 88.9%, 96.0%, 96.0%, 88.9%; and (d) 74.1%, 96.0%, 95.2%, 77.4%. There were significant differences for each index. Muscle weakness during the empty and full can tests was not useful in differentiating rotator cuff tears from CSA because of low specificity and PPV. However, pain provocation was useful in differentiating these two conditions because of high specificity and PPV.

  19. Dual p16 and Ki-67 Expression in Liquid-Based Cervical Cytological Samples Compared to Pap Cytology Findings, Biopsies, and HPV Testing in Cervical Cancer Screening: A Diagnostic Accuracy Study.

    Science.gov (United States)

    Prigenzi, Karla Calaça Kabbach; Heinke, Thaís; Salim, Rafael Calil; Focchi, Gustavo Rubino de Azevedo

    2018-01-01

    Our objective was to verify the sensitivity and specificity of dual immunocytochemistry staining for p16 and Ki-67 in liquid-based samples (the "dual" assay) for cervical lesion screening, compared to biopsy findings and human papillomavirus (HPV) DNA molecular detection. Sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values for the "dual immunocytochemistry assay" were calculated and compared to histopathological results and to high-risk HPV DNA detection in adult women or teenagers submitted to cervical cancer screening. A total of 151 women were included. The majority (96.2%) of those with negative dual assay results had lower biopsy grades (p cytology results suggestive of cervical cancer had positive dual immunocytochemistry assay results more frequently (p < 0.001), and these positive results were also significantly associated with biopsy findings (p < 0.001) and with high-risk genotype HPV infection (p = 0.007). Specificity and PPV for the dual assay were 0.972 (0.855-0.999) and 0.800 (0.284-0.995), respectively, and 1.000 (0.590-1.000) and 1.000 (0.631-1.000) for HPV detection. The dual immunocytochemistry assay had high specificity and PPV. It reveals a persistent HPV infection, avoiding the need for new tissue collections for biopsies or hybrid capture. © 2018 S. Karger AG, Basel.

  20. Choosing algorithms for TB screening: a modelling study to compare yield, predictive value and diagnostic burden.

    Science.gov (United States)

    Van't Hoog, Anna H; Onozaki, Ikushi; Lonnroth, Knut

    2014-10-19

    To inform the choice of an appropriate screening and diagnostic algorithm for tuberculosis (TB) screening initiatives in different epidemiological settings, we compare algorithms composed of currently available methods. Of twelve algorithms composed of screening for symptoms (prolonged cough or any TB symptom) and/or chest radiography abnormalities, and either sputum-smear microscopy (SSM) or Xpert MTB/RIF (XP) as confirmatory test we model algorithm outcomes and summarize the yield, number needed to screen (NNS) and positive predictive value (PPV) for different levels of TB prevalence. Screening for prolonged cough has low yield, 22% if confirmatory testing is by SSM and 32% if XP, and a high NNS, exceeding 1000 if TB prevalence is ≤0.5%. Due to low specificity the PPV of screening for any TB symptom followed by SSM is less than 50%, even if TB prevalence is 2%. CXR screening for TB abnormalities followed by XP has the highest case detection (87%) and lowest NNS, but is resource intensive. CXR as a second screen for symptom screen positives improves efficiency. The ideal algorithm does not exist. The choice will be setting specific, for which this study provides guidance. Generally an algorithm composed of CXR screening followed by confirmatory testing with XP can achieve the lowest NNS and highest PPV, and is the least amenable to setting-specific variation. However resource requirements for tests and equipment may be prohibitive in some settings and a reason to opt for symptom screening and SSM. To better inform disease control programs we need empirical data to confirm the modeled yield, cost-effectiveness studies, transmission models and a better screening test.

  1. Enabling minimal invasive parathyroidectomy for patients with primary hyperparathyroidism using Tc-99m-sestamibi SPECT–CT, ultrasound and first results of {sup 18}F-fluorocholine PET–CT

    Energy Technology Data Exchange (ETDEWEB)

    Kluijfhout, Wouter P., E-mail: WPKluijfhout@gmail.com [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Vorselaars, Wessel M.C.M., E-mail: W.M.Vorselaars@umcutrecht.nl [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Vriens, Menno R., E-mail: mvriens@umcutrecht.nl [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Borel Rinkes, Inne H.M., E-mail: I.H.M.BorelRinkes@umcutrecht.nl [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Valk, Gerlof D., E-mail: G.D.Valk@umcutrecht.nl [Department of Endocrinology, University Medical Center Utrecht, Utrecht (Netherlands); Keizer, Bart de, E-mail: B.deKeizer@umcutrecht.nl [Department of Nuclear Medicine and Radiology, University Medical Center Utrecht, Utrecht (Netherlands)

    2015-09-15

    Highlights: • We examined an optimal pre-operative imaging strategy. • Goal was to perform minimal invasive parathyroidectomy. • Ultrasound significantly decreased the PPV when added to SPECT–CT. • {sup 18}F-fluorocholine was positive in 4/5 cases with negative conventional imaging. - Abstract: Objective: Assessment of the diagnostic value of ultrasound (US), single photon-emission computed tomography–computed tomography (SPECT–CT) and {sup 18}F-fluorocholine (FCH) PET–CT for preoperative localization of hyper-functioning parathyroid(s) in order to create a more efficient diagnostic pathway and enable minimal invasive parathyroidectomy (MIP) in patients with biochemical proven non-familial primary hyperparathyroidism (pHPT). Methods: A single-institution retrospective study of 63 consecutive patients with a biochemical diagnosis of non-familial pHPT who received a Tc-99m-sestamibi SPECT–CT and neck ultrasound. Surgical findings were used in calculating the sensitivity and the positive predictive value (PPV) of both imaging modalities. Furthermore we present 5 cases who received additional FCH PET–CT. Results: A total of 42 (66.7%) patients underwent MIP. The PPV and sensitivity of SPECT–CT, 93.0% and 80.3%, were significantly higher than those of US with 78.3% and 63.2%, respectively. Adding US to SPECT–CT for initial pre-operative localization did not significantly increase sensitivity but did significantly decrease PPV. Performance of US was significantly better when performed after SPECT–CT. {sup 18}F-fluorocholine PET–CT localized the hyper-functioning parathyroid gland in 4/5 cases with discordant conventional imaging, enabling MIP. Conclusion: SPECT–CT is the imaging modality of choice for initial pre-operative localization of hyper-functioning parathyroid gland(s) in patients with biochemical pHPT. Ultrasound should be performed after SPECT–CT for confirmation of positive SPECT–CT findings and for pre-operative marking

  2. Training for assessment of negative symptoms of schizophrenia across languages and cultures: comparison of the NSA-16 with the PANSS Negative Subscale and Negative Symptom factor.

    Science.gov (United States)

    Daniel, David G; Alphs, Larry; Cazorla, Pilar; Bartko, John J; Panagides, John

    2011-07-01

    The 16-item Negative Symptom Assessment scale (NSA-16) has been validated in English-speaking raters. We analyzed the level of agreement achieved among raters of different nationalities using the NSA-16 and the Positive and Negative Syndrome Scale (PANSS) negative subscale and Marder negative factor. Raters participating in two international trials were trained in the use of each instrument through lectures and feedback on their ratings of at least one videotaped interview of a schizophrenic patient. Overall and regional (North America, Western Europe, Eastern Europe, South/Central America, and Australia and South Africa combined) kappa values were calculated and mean total scores were compared (1-way analysis of variance) by region for each instrument. In addition, within-scales variance was calculated by item to help identify negative symptoms that were particularly challenging to obtain agreement on across cultures. In the combined group of international raters, the kappa values for ratings of the NSA-16, PANSS negative subscale, and Marder negative factors were 0.89, 0.84, and 0.82, respectively. Kappa values calculated by geographic region ranged from 0.87 to 0.94 for the NSA-16 compared with 0.82 to 0.86 for the PANSS negative subscale and 0.79 to 0.87 for the PANSS Marder negative factor. Despite cultural and linguistic differences among raters, standardizing measurement of negative symptoms in international clinical trials is possible using available rating scales: NSA-16, PANSS negative subscale, and Marder negative subscale. Agreement among raters was at least as high using the NSA-16 as using the PANSS instruments.

  3. Comparison of three assays currently used for diagnosis of legionellosis

    Directory of Open Access Journals (Sweden)

    Maria Chiucini

    2010-12-01

    Full Text Available The laboratory diagnosis of Legionnaires’ disease is extremely complex due to the difficulty of isolating and identifying the etiological agent in a short time and also for the frequent late appearance of antibodies. For this reason it should use not only the cultures but also other diagnostic tests such as urinary antigen and antibody research. Our study evaluated the performance of these methods.We calculated the positive predictive value (PPV and negative predictive value (NPV, sensitivity and specificity of each test.

  4. Comparison of 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test in assessing pancreatic exocrine sufficiency in children with chronic pancreatitis.

    Science.gov (United States)

    Wejnarska, Karolina; Kołodziejczyk, Elwira; Ryżko, Józef; Oracz, Grzegorz

    Chronic pancreatitis (CP) in children is still a rare, although increasingly recognized entity. Over the duration of the disease several complications can be observed, two of which are major ones: endo- and exocrine insufficiency. In the medical care of children with CP it is crucial to diagnose the decreased endo- and exocrine function of the pancreas, in order to preserve patients from malnutrition and the failure to thrive. The aim of the study was to compare the usefulness of two indirect methods of assessing the pancreas exocrine function in children with CP. Ninety one patients with CP were enrolled in the study (41 boys, 50 girls, aged 2-17.8 years). Only Patients who had had both the 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test (13C -MTBT) performed were selected. We compared the results of both tests for sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) in detecting exocrine pancreatic insufficiency. Out of 91 patients, 12 were diagnosed with exocrine pancreatic insufficiency (EPI). The sensitivity of the fecal fat quantification was 50%, the specificity for the test was 100%. PPV and NPV were 100% and 93%, respectively. 13C-MTBT had the sensitivity of 42% and the specificity of 99%. PPV and NPV for the breath test were of 83% and 92%, respectively. No statistically significant discrepancy between the values obtained was found. Although the 72-hour fecal fat quantification remains the gold standard in detecting EPI, both of the methods that had been investigated were shown to be comparable regarding sensitivity, specificity, PPV and NPV in assessing pancreas exocrine sufficiency in children with CP. Due to the easier execution of the breath test, both for the patient and for medical personnel, its importance may increase.

  5. Comparison of Diagnostic Performance of US Elastography and Conventional B-mode US in Differentiation of Breast Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ji Young; Lee, Jin Hwa; Cho, Jin Han; Ha, Dong Ho; Park, Byeong Ho; Choi, Sun Seob [Dept. of Radiology, Dong-A University College of Medicine, Busan (Korea, Republic of); Kim, Eun Kyung [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Shin, Su Young [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Byeong Ho [Dept. of Preventive Medicine, Dong-A University College of Medicine, Busan (Korea, Republic of)

    2012-08-15

    The purpose of this study was to compare the diagnostic performance of ultrasound (US) elastography and conventional B-mode US for discrimination between benign and malignant breast lesions. During a 13-month period, 277 women with 335 sonographically visible breast lesions who were scheduled to undergo biopsy were examined with US elastography. Elastographic findings were classified as benign or malignant based on the area ratio, with 1.00 as the threshold. Findings on conventional B mode US were classified according to the BI-RADS category, as follows: lesions of BIRADS categories 2 and 3 were considered benign, while those in categories 4 and 5 were considered malignant. Statistical analysis included sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and ROC curve analysis for comparison of the diagnostic performance of US elastography and conventional B-mode US. Of the 335 breast lesions, 85 (25.4%) showed malignancy on pathology. Findings on B-mode US showed malignancy in 264 (78.8%) and elastographic findings showed malignancy in 102 (30.4%). The sensitivity, specificity, PPV, NPV, and accuracy of B-mode US and elastography were 98.8%, 28.0%, 31.8%, 98.6%, and 79.4% and 69.4%, 81.2%, 57.8%, 88.8%, and 79.4%, respectively. Elastography showed significantly higher specificity and PPV and lower sensitivity and NPV, compared with B-mode US (p < 0.001). The area under the ROC curve (AUC value) was 0.761 for elastography, and 0.634 for B-mode US (p < 0.001). US elastography can improve specificity and PPV of B-mode US, but with significant sacrifice of sensitivity and NPV. Therefore, US elastography may complement B-mode US for differentiation of breast masses.

  6. Synovialisation of the torn anterior cruciate ligament of the knee: comparison between magnetic resonance and arthroscopy

    International Nuclear Information System (INIS)

    Higueras Guerrero, V.; Torregrosa Andres, A.; Marti-Bonmati, L.; Casillas, C.; Sanfeliu, M.

    1999-01-01

    The aim of this study was to assess the accuracy of MR in the diagnosis of synovialisation of the anterior cruciate ligament (ACL) compared with arthroscopy. One hundred and forty-nine patients were examined with MR imaging and arthroscopy of the knee. The MR sign used to consider a synovialised ACL consisted of hypointense fibrillar tracts, disrupted and wavily, in its expected course. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), comparison of proportions (McNemar test) and Kappa values for agreement between MR imaging and arthroscopy were calculated. Of the 133 (89.3 %) ligaments without synovialisation at arthroscopy, 130 accorded with the MR results. Of the 16 (10.7 %) synovialised ligaments, 13 accorded with the MR results. Three false-positive and three false-negative MR diagnoses were identified. The agreement between both techniques was excellent (Kappa = 0.79; p = 0.000), without differences (McNemar test; p = 1). Sensitivity was 0.81, specificity 0.98, PPV 0.98 and NPV 0.81. Magnetic resonance imaging is highly reliability for synovialisation diagnosis. The imaging sign used to diagnose synovialised ACL (hypointense comma-like tracts in its expected course) is reliable. As this reparative process can simulate an intact ligament, knowledge of this sign is important in diagnosing synovialisation of ACL tears so as not to confuse it with normal ACL. (orig.)

  7. The Role of Positron Emission Tomography/Computed Tomography Imaging in Head and Neck Cancer after Radical Chemoradiotherapy: a Single Institution Experience.

    Science.gov (United States)

    Nelissen, C; Sherriff, J; Jones, T; Guest, P; Colley, S; Sanghera, P; Hartley, A

    2017-11-01

    Positron emission tomography/computed tomography (PET/CT) is used to restage head and neck cancer 3 months after chemoradiotherapy. The purpose of this study was to determine the negative predictive value (NPV) of a scan reported as having no abnormal uptake and the positive predictive values (PPV) for different maximum standardised uptake value (SUVmax) thresholds. Patients with squamous cell carcinoma of the oro-/hypopharynx/larynx (n = 206) were included. SUVmax and subsequent locoregional recurrence were documented. The median SUVmax was 11.2 (range 4-33)/4.6 (range 2-30), respectively, in patients with/without definite primary site recurrence (P = 0.004). The median SUVmax was 4.4 (range 2.6-15.6)/3.1 (range 2.1-4.6), respectively, in patients with/without definite nodal recurrence (P = 0.003). The NPV for a scan reported as having no abnormal uptake was 92%. The PPV for the SUVmax thresholds 4, 6 and 8, respectively, were 53, 65 and 92% (primary site) and 93, 100 and 100% (nodes). The NPV of PET/CT after chemoradiation is consistent with the literature and underlines the importance of PET/CT in restaging the primary site if salvage neck dissection is considered. The overall PPV of PET/CT remains low but is high for nodal SUVmax > 4. These data could be used to design risk-stratified follow-up schedules. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  8. Diagnostic value of glypican-3 in alpha fetoprotein negative ...

    African Journals Online (AJOL)

    Background: The prognosis of patients with hepatocellular carcinoma(HCC) is generally very poor with a 5-year survival rate of less than 15% since most of them are diagnosed clinically at their late stage.However,the differential diagnosis between alpha fetoprotein(AFP) negative HCC and cirrhotic nodules is still difficult.

  9. Strain ratio ultrasound elastography increases the accuracy of colour-Doppler ultrasound in the evaluation of Thy-3 nodules. A bi-centre university experience.

    Science.gov (United States)

    Cantisani, Vito; Maceroni, Piero; D'Andrea, Vito; Patrizi, Gregorio; Di Segni, Mattia; De Vito, Corrado; Grazhdani, Hektor; Isidori, Andrea M; Giannetta, Elisa; Redler, Adriano; Frattaroli, Fabrizio; Giacomelli, Laura; Di Rocco, Giorgio; Catalano, Carlo; D'Ambrosio, Ferdinando

    2016-05-01

    To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.

  10. Diagnostic utility of a one-item question to screen for depressive disorders: results from the KORA F3 study.

    Science.gov (United States)

    Blozik, Eva; Scherer, Martin; Lacruz, Maria E; Ladwig, Karl-Heinz

    2013-12-23

    Screening for depressive disorders in the general adult population is recommended, however, it is unclear which instruments combine user friendliness and diagnostic utility. We evaluated the test performance of a yes/no single item screener for depressive disorders ("Have you felt depressed or sad much of the time in the past year?") in comparison to the depressive disorder module of the Patient Health Questionnaire (PHQ-9). Data from 3184 participants of the population-based KORA F3 survey in Augsburg/ Germany were used to analyse sensitivity, specificity, ROC area, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), and negative predictive value (NPV) of the single item screener in comparison with "depressive mood" and "major depressive disorder" defined according to PHQ-9 (both interviewer-administered versions). In comparison to PHQ-9 "depressive mood", sensitivity was low (46%) with an excellent specificity (94%), (PPV 76%; NPV 82%; LR + 8.04; LR- .572, ROC area .702). When using the more conservative definition for "major depressive disorder", sensitivity increased to 83% with a specificity of 88%. The PPV under the conservative definition was low (32%), but NPV was 99% (LR + 6.65; LR- .196; ROC area .852). Results varied across age groups and between males and females. The single item screener is able to moderately decrease post-test probability of major depressive disorders and to identify populations that should undergo additional, more detailed evaluation for depression. It may have limited utility in combination with additional screening tests or for selection of at-risk populations, but cannot be recommended for routine use as a screening tool in clinical practice.

  11. Prognostic value of brain proton MR spectroscopy and diffusion tensor imaging in newborns with hypoxic-ischemic encephalopathy treated by brain cooling

    Energy Technology Data Exchange (ETDEWEB)

    Ancora, G. [Neonatal Intensive Care Unit, Department of Mother and Infant Infermi Hospital of Rimini, Rimini (Italy); Testa, C.; Tonon, C.; Manners, D.N.; Gramegna, L.L.; Lodi, R. [Department of Biomedical and Neuromotor Sciences University of Bologna, MR Functional Unit, Bologna (Italy); Grandi, S.; Sbravati, F.; Savini, S.; Corvaglia, L.T.; Faldella, G. [University of Bologna, Neonatology Unit, Department of Woman, Child and Adolescent Health, Bologna (Italy); Tani, G. [University of Bologna, Radiology Unit, Department of Woman, Child and Adolescent Health, Bologna (Italy); Malucelli, E. [University of Bologna, Department of Pharmacy and Biotechnologies, Bologna (Italy)

    2013-08-15

    MRI, proton magnetic resonance spectroscopy ({sup 1}H-MRS), and diffusion tensor imaging (DTI) have been shown to be of great prognostic value in term newborns with moderate-severe hypoxic-ischemic encephalopathy (HIE). Currently, no data are available on {sup 1}H-MRS and DTI performed in the subacute phase after hypothermic treatment. The aim of the present study was to assess their prognostic value in newborns affected by moderate-severe HIE and treated with selective brain cooling (BC). Twenty infants treated with BC underwent conventional MRI and {sup 1}H-MRS at a mean (SD) age of 8.3 (2.8) days; 15 also underwent DTI. Peak area ratios of metabolites and DTI variables, namely mean diffusivity (MD), axial and radial diffusivity, and fractional anisotropy (FA), were calculated. Clinical outcome was monitored until 2 years of age. Adverse outcome was observed in 6/20 newborns. Both {sup 1}H-MRS and DTI variables showed higher prognostic accuracy than conventional MRI. N-acetylaspartate/creatine at a basal ganglia localisation showed 100 % PPV and 93 % NPV for outcome. MD showed significantly decreased values in many regions of white and gray matter, axial diffusivity showed the best predictive value (PPV and NPV) in the genu of corpus callosum (100 and 91 %, respectively), and radial diffusivity was significantly decreased in fronto white matter (FWM) and fronto parietal (FP) WM. The decrement of FA showed the best AUC (0.94) in the FPWM. Selective BC in HIE neonates does not affect the early and accurate prognostic value of {sup 1}H-MRS and DTI, which outperform conventional MRI. (orig.)

  12. The diagnostic value of PET/CT imaging with the {sup 68}Ga-labelled PSMA ligand HBED-CC in the diagnosis of recurrent prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Afshar-Oromieh, Ali; Giesel, Frederik L.; Kratochwil, Clemens; Haberkorn, Uwe [University Hospital of Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Centre, Heidelberg (Germany); Avtzi, Eleni [University Hospital of Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Holland-Letz, Tim [German Cancer Research Center, Department of Biostatistics, Heidelberg (Germany); Linhart, Heinz G. [German Cancer Research Centre, Heidelberg, National Centre for Tumor Diseases (NCT), Heidelberg (Germany); Eder, Matthias; Eisenhut, Michael; Kopka, Klaus [German Cancer Research Center, Division of Radiopharmaceutical Chemistry, Heidelberg (Germany); Boxler, Silvan; Hadaschik, Boris A. [University Hospital of Heidelberg, Department of Urology, Heidelberg (Germany); Weichert, Wilko [University Hospital of Heidelberg, Department of Pathology, Heidelberg (Germany); Debus, Juergen [University Hospital Heidelberg, Department of Radiation Oncology and Therapy, Heidelberg (Germany)

    2014-11-20

    Since the introduction of positron emission tomography (PET) imaging with {sup 68}Ga-PSMA-HBED-CC (={sup 68}Ga-DKFZ-PSMA-11), this method has been regarded as a significant step forward in the diagnosis of recurrent prostate cancer (PCa). However, published data exist for small patient cohorts only. The aim of this evaluation was to analyse the diagnostic value of {sup 68}Ga-PSMA-ligand PET/CT in a large cohort and the influence of several possibly interacting variables. We performed a retrospective analysis in 319 patients who underwent {sup 68}Ga-PSMA-ligand PET/CT from 2011 to 2014. Potential influences of several factors such as prostate-specific antigen (PSA) level and doubling time (DT), Gleason score (GSC), androgen deprivation therapy (ADT), age and amount of injected tracer were evaluated. Histological verification was performed in 42 patients after the {sup 68}Ga-PSMA-ligand PET/CT. Tracer uptake was measured in 901 representative tumour lesions. In 82.8 % of the patients at least one lesion indicative of PCa was detected. Tumor-detection was positively associated with PSA level and ADT. GSC and PSA-DT were not associated with tumor-detection. The average maximum standardized uptake value (SUV{sub max}) of tumour lesions was 13.3 ± 14.6 (0.7-122.5). Amongst lesions investigated by histology, 30 were false-negative in 4 different patients, and all other lesions (n = 416) were true-positive or true-negative. A lesion-based analysis of sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) revealed values of 76.6 %, 100 %, 91.4 % and 100 %. A patient-based analysis revealed a sensitivity of 88.1 %. Of 116 patients available for follow-up, 50 received local therapy after {sup 68}Ga-PSMA-ligand PET/CT. {sup 68}Ga-PSMA-ligand PET/CT can detect recurrent PCa in a high number of patients. In addition, the radiotracer is highly specific for PCa. Tumour detection is positively associated with PSA and ADT. {sup 68}Ga

  13. A Values-Affirmation Intervention Does Not Benefit Negatively Stereotyped Immigrant Students in the Netherlands

    Directory of Open Access Journals (Sweden)

    Elisabeth Margaretha De Jong

    2016-05-01

    Full Text Available Previous research showed that a values-affirmation intervention can help reduce the achievement gap between African American and European American students in the US. In the present study, it was examined if these results would generalize to ethnic minority students in a country outside the US, namely the Netherlands, where there is also an achievement gap between native and ethnic minority students. This type of intervention was tested in two separate studies, the first among first-year pre-vocational students (n = 361, 84% ethnic minority, and the second among sixth grade students (n = 290, 96% ethnic minority. Most minority participants had a Turkish-Dutch or Moroccan-Dutch immigrant background. In the second study, a third condition was added to the original paradigm, in which students elaborated on either their affirmation- or a control exercise with the help of a teaching assistant. We also examined whether values affirmation affected the level of problem behavior of negatively stereotyped ethnic minority youth. Contrary to what was expected, multilevel analyses revealed that the intervention had no effect on the school achievement or the problem behavior of the ethnic minority students. Possible explanations for these findings, mainly related to contextual and cultural differences between the Netherlands and the US, are discussed.

  14. Towards a non-invasive method for early detection of testicular neoplasia in semen samples by identification of fetal germ cell-specific markers

    DEFF Research Database (Denmark)

    Hoei-Hansen, C E; Carlsen, E; Jorgensen, N

    2007-01-01

    /gonocyte markers is presented. METHODS: Immunocytological staining for AP-2gamma [and in some cases, OCT-3/4, NANOG or placental alkaline phosphatase (PLAP)] was performed in semen samples from 294 infertile patients and 209 patients with TGCTs or other diseases. RESULTS: Presence of AP-2gamma-stained cells...... but reduced in participants with overt TGCTs, perhaps because of obstruction. Assay specificity was 93.6%, positive predictive value (PPV) 83.3% and negative predictive value (NPV) 60.3%. CONCLUSIONS: Immunocytological semen analysis based on expression of fetal germ cell markers in exfoliated cells has...

  15. Evaluation of an On-Farm Culture System (Accumast for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows.

    Directory of Open Access Journals (Sweden)

    Erika Korzune Ganda

    Full Text Available The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538 was cultured on-farm using a single plate containing three selective chromogenic media (Accumast-FERA Animal Health LCC, Ithaca, NY and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214. In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV and negative predictive value (NPV were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively.

  16. Evaluation of an On-Farm Culture System (Accumast) for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows.

    Science.gov (United States)

    Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho

    2016-01-01

    The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast-FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively.

  17. [Evaluation of a rapid diagnostic test in the diagnosis of toxoplasmosis in pregnant women in Cotonou (Bénin)].

    Science.gov (United States)

    Ogouyèmi-Hounto, A; Agbayahoun-Chokki, F; Sissinto Savi de Tove, Y; Biokou Bankole, B; Adinsi de Souza, V; Assogba, M; Kinde-Gazard, D; Massougbodji, A

    2014-05-01

    The aim of the study was to evaluate the performance of the ImmunoComb® Toxo IgG and ImmunoComb® Toxo IgMassays (rapid diagnostic test) in the laboratory diagnosis of toxoplasmosis in pregnant women in Cotonou. We interviewed 266 pregnant women, who first answered an epidemiological questionnaire, and collected blood samples for measurement of IgG and IgM anti T. gondii antibodies with the ImmunoComb toxo assays and with the ARCHITECT CIMA method. The sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) were calculated to determine the performance of the rapid test. The seroprevalences of IgG against T. gondii by CIMA technique and rapid test were respectively 48.9% and 48.5%. The prevalence increased with age. Performances for IgG were: sensitivity 97%, specificity 100%, PPV 100%, NPV = 97.10%. For IgM, Sensitivity: 33.3% Specificity: 100%, PPV 100%, NPV = 99.2%. Seroprevalence obtained shows that about half of the study population is not immune against T. gondii and requires regular serological monitoring until delivery. According to these results, and given the needs of toxoplasmosis diagnosis on the field characterized by an important decrease of immunized women, this test may be recommended in the laboratory diagnosis of toxoplasmosis in peripheral levels of the health pyramid.

  18. Can routine chest radiography be used to diagnose mild COPD? A nested case-control study.

    Science.gov (United States)

    den Harder, A M; Snoek, A M; Leiner, T; Suyker, W J; de Heer, L M; Budde, R P J; Lammers, J W J; de Jong, P A; Gondrie, M J A

    2017-07-01

    To determine whether mild stage chronic obstructive pulmonary disease (COPD) can be detected on chest radiography without substantial overdiagnosis. A retrospective nested case-control study (case:control, 1:1) was performed in 783 patients scheduled for cardiothoracic surgery who underwent both spirometry and a chest radiograph preoperative. Diagnostic accuracy of chest radiography for diagnosing mild COPD was investigated using objective measurements and overall appearance specific for COPD on chest radiography. Inter-observer variability was investigated and variables with a kappa >0.40 as well as baseline characteristics were used to make a diagnostic model which was aimed at achieving a high positive predictive value (PPV). Twenty percent (155/783) had COPD. The PPV of overall appearance specific for COPD alone was low (37-55%). Factors in the diagnostic model were age, type of surgery, gender, distance of the right diaphragm apex to the first rib, retrosternal space, sternodiaphragmatic angle, maximum height right diaphragm (lateral view) and subjective impression of COPD (using both views). The model resulted in a PPV of 100%, negative predictive value (NPV) of 82%, sensitivity of 10% and specificity of 100% with an area under the curve of 0.811. Detection of mild COPD without substantial overdiagnosis was not feasible on chest radiographs in our cohort. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Diagnostic accuracy of CT in assessing extra-regional lymphadenopathy in pancreatic and peri-ampullary cancer: a systematic review and meta-analysis.

    Science.gov (United States)

    Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus

    2014-12-01

    Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Influence of clinical information on the diagnostic validity of MRI in the detection of abacterial sacroiliitis; Einfluss klinischer Informationen auf die diagnostische Wertigkeit der MRT bei der Frage nach einer abakteriellen Sakroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Remplik, P.; Schukai, O.; Roemer, F.W.; Fischer, W.; Buecklein, W.; Mott, K.; Bohndorf, K. [Klinik fuer Diagnostische Radiologie und Neuroradiologie, Klinikum Augsburg (Germany); Schalm, J. [3. Medizinische Klinik, Funktionsbereich Rheumatologie, Klinikum Augsburg (Germany)

    2005-06-01

    Purpose: to evaluate the influence of clinical information on the diagnostic validity of MRI in the detection of abacterial sacroiliitis. Evaluation of sensitivities, specificities, negative (NPV) and positive predictive values (PPV) for MRI with and without clinical information in comparison to a prior defined standard. Materials and methods: the results of routine MRI reports of 65 patients with the clinical suspicion of abacterial sacroiliitis referred by rheumatologists for MR assessment of the sacroiliac joints were retrospectively reviewed. These results were compared to the results of a blinded reading of the same examinations performed without any clinical information. The MRI protocol included T1-SE, STIR and T1-SE contrast-enhanced sequences with fat saturation. All patients were followed for at least four years. The standard of reference was defined by an experienced rheumatologist and included baseline and follow-up data (clinical, laboratory and imaging). Abacterial sacroiliitis was diagnosed in 19 patients. Results: under routine clinical conditions, MRI revealed a sensitivity of 94.7% and specificity of 97.8%. A PPV of 94.7% and a NPV of 97.8% were achieved. Without clinical information, MRI revealed a sensitivity and specificity of 64 and 80%, and a PPV of 49% and a NPV of 86%, respectively. Conclusion: the additional knowledge of clinical information for the MR diagnosis of abacterial sacroiliitis increases its diagnostic value for the assessment of abacterial sacroiliitis. (orig.)

  1. The Usefulness of Clinical-Practice-Based Laboratory Data in Facilitating the Diagnosis of Dengue Illness

    Directory of Open Access Journals (Sweden)

    Jien-Wei Liu

    2013-01-01

    Full Text Available Alertness to dengue and making a timely diagnosis is extremely important in the treatment of dengue and containment of dengue epidemics. We evaluated the complementary role of clinical-practice-based laboratory data in facilitating suspicion/diagnosis of dengue. One hundred overall dengue (57 dengue fever [DF] and 43 dengue hemorrhagic fever [DHF] cases and another 100 nondengue cases (78 viral infections other than dengue, 6 bacterial sepsis, and 16 miscellaneous diseases were analyzed. We separately compared individual laboratory variables (platelet count [PC] , prothrombin time [PT], activated partial thromboplastin time [APTT], alanine aminotransferase [ALT], and aspartate aminotransferase [AST] and varied combined variables of DF and/or DHF cases with the corresponding ones of nondengue cases. The sensitivity, specificity, accuracy, positive predictive value (PPV, and negative predictive value (NPV in the diagnosis of DF and/or DHF were measured based on these laboratory variables. While trade-off between sensitivity and specificity, and/or suboptimal PPV/NPV was found at measurements using these variables, prolonged APTT + normal PT + PC < 100 × 109 cells/L had a favorable sensitivity, specificity, PPV, and NPV in diagnosis of DF and/or DHF. In conclusion, these data suggested that prolonged APTT + normal PT + PC < 100 × 109 cells/L is useful in evaluating the likelihood of DF and/or DHF.

  2. Evaluation of dried blood spot samples for screening of hepatitis C and human immunodeficiency virus in a real-world setting.

    Science.gov (United States)

    Vázquez-Morón, Sonia; Ryan, Pablo; Ardizone-Jiménez, Beatriz; Martín, Dolores; Troya, Jesus; Cuevas, Guillermo; Valencia, Jorge; Jimenez-Sousa, María A; Avellón, Ana; Resino, Salvador

    2018-01-30

    Both hepatitis C virus (HCV) infection and human immunodeficiency virus (HIV) infection are underdiagnosed, particularly in low-income countries and in difficult-to-access populations. Our aim was to develop and evaluate a methodology for the detection of HCV and HIV infection based on capillary dry blood spot (DBS) samples taken under real-world conditions. We carried out a cross-sectional study of 139 individuals (31 healthy controls, 68 HCV-monoinfected patients, and 40 HCV/HIV-coinfected patients). ELISA was used for anti-HCV and anti-HIV antibody detection; and SYBR Green RT-PCR was used for HCV-RNA detection. The HIV serological analysis revealed 100% sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The HCV serological analysis revealed a sensitivity of 92.6%, specificity of 100%, PPV of 100%, and NPV of 79.5%. Finally, the HCV-RNA detection test revealed a detection limit of 5 copies/µl with an efficiency of 100% and sensitivity of 99.1%, specificity of 100%, PPV of 100%, and NPV of 96.9%. In conclusion, our methodology was able to detect both HCV infection and HIV infection from the same DBS sample with good diagnostic performance. Screening for HCV and HIV using DBS might be a key strategy in the implementation of national programs for the control of both infections.

  3. Value of FibroScan in diagnosis of hepatic fibrosis in patients with HBeAg-negative chronic hepatitis B

    Directory of Open Access Journals (Sweden)

    LUO Junhua

    2014-07-01

    Full Text Available ObjectiveTo evaluate the value of transient elastography (FibroScan, FS in predicting hepatic fibrosis in patients with HBeAg-negative chronic hepatitis B (CHB. MethodsOne hundred and four patients with HBeAg-negative CHB, who were diagnosed and treated in Hubei Hospital of Traditional Chinese Medicine from June 2011 to May 2013, were enrolled in this study. All patients underwent FS for liver stiffness measurement before liver biopsy. Statistical analysis was applied to compare liver stiffness (kPa with fibrosis stage (determined by liver biopsy. The receiver operating characteristic (ROC curve of FS was constructed, and the area under the ROC curve (AUROC was calculated to analyze the accuracy of live stiffness in predicting significant fibrosis and cirrhosis. Comparison between groups was made by Kruskal-Wallis H test, followed by Mann-Whitney U test for multiple comparisons. The correlation between two variables was analyzed by Spearman rank and Pearson correlation test. ResultsLiver stiffness gradually rose as the degree of hepatic fibrosis increased, with significant differences between groups (P<0.01 or P<0.05. Liver stiffness was positively correlated with the stage of hepatic fibrosis (r=0.810, P<0.01. The AUROC of liver stiffness for detecting liver cirrhosis was 0.956; the cut-off value for diagnosing liver cirrhosis was 13.1 kPa; the sensitivity was 92.7%, and the specificity was 80%. ConclusionFS is a promising noninvasive method for the assessment of hepatic fibrosis in patients with HBeAg-negative CHB; particularly, it has high accuracy in the diagnosis of liver cirrhosis. FS combined with direct or indirect markers may play an important role in differential diagnosis and efficacy evaluation in patients with hepatic fibrosis.

  4. Acute pulmonary embolism: prediction of cor pulmonale and short-term patient survival from assessment of cardiac dimensions in routine multidetector-row CT

    International Nuclear Information System (INIS)

    Engeike, C.; Rummeny, E.; Marten, K.

    2006-01-01

    Purpose: evaluation of the prognostic value of morphological cardiac parameters in patients with suspected and incidental acute pulmonary embolism (PE) using multidetector-row chest CT (MSCT). Materials and methods: 2335 consecutive MSCT scans were evaluated for the presence of PE. The arterial enhancement and analysability of pulmonary arteries and the heart were assessed as parameters of the scan quality. The diastolic right and left ventricular short axes (RV D , LV D ) and the interventricular septal deviation (ISD) were measured in all PE-positive patients and the echocardiography reports were reviewed. The clinical data assessment included cardio-respiratory and other co-morbidities, systemic anticoagulant therapy (ACT), and the 30-day outcome. Predictors of acute cor pulmonale and the short-term outcome were calculated by univariate and multivariate logistic regressions including odds ratios (OR) and ROC analyses using positive (PPV) and negative predictive values (NPV). Results: 90 patients with acute PE were included (36 with clinically suspected PE, 54 with incidental PE). 26 patients had cardio-respiratory co-morbidities. Four patients underwent systemic thrombolysis, 43 underwent anticoagulation in therapeutic doses, 19 underwent anticoagulation in prophylactic doses, and 24 patients did not undergo ACT. 15 of 41 patients had echocardiographic evidence of acute cor pulmonale. 8 patients died within 30 days. The RV D was the best independent predictor of acute cor pulmonale (p = 0,002, OR = 9.16, PPV = 0.68, NPV=1 at 4.49 cm cut off) and short-term outcome (p= 0,0005, OR = 2.82, PPV = 0.23, NPV = 0.98 at 4.75 cm cut off). The RV D /LV D ratio had a PPV of 0.85 for cor pulmonale. (orig.)

  5. Applicability of McDonald 2010 and Magnetic Resonance Imaging in Multiple Sclerosis (MAGNIMS) 2016 Magnetic Resonance Imaging Criteria for the Diagnosis of Multiple Sclerosis in Sri Lanka.

    Science.gov (United States)

    Gamage, Sujani Madhurika Kodagoda; Wijeweera, Indunil; Wijesinghe, Priyangi; Adikari, Sanjaya Bandara; Fink, Katharina; Sominanda, Herath Mudiyanselage Ajith

    2018-05-31

    The magnetic resonance imaging in multiple sclerosis (MAGNIMS) group recently proposed guidelines to replace the existing dissemination-in-space criteria in McDonald 2010 magnetic resonance imaging (MRI) criteria for diagnosing multiple sclerosis. There has been insufficient research regarding their applicability in Asians. Objective of this study was to determine the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of McDonald 2010 and MAGNIMS 2016 MRI criteria with the aim of verifying their applicability in Sri Lankan patients. Patients with clinically isolated syndrome diagnosed by consultant neurologists were recruited from five major neurology centers. Baseline and follow-up MRI scans were performed within 3 months from the initial presentation and at one year after baseline MRI, respectively. McDonald 2010 and MAGNIMS 2016 MRI criteria were applied to all MRI scans. Patients were followed-up for 2 years to assess the conversion to clinically definite multiple sclerosis (CDMS). The sensitivity, specificity, accuracy, PPV, and NPV for predicting the conversion to CDMS were calculated. Forty-two of 66 patients converted to CDMS. Thirty-seven fulfilled the McDonald 2010 MRI criteria, and 33 converted to CDMS. MAGNIMS 2016 MRI criteria were fulfilled by 29, with 28 converting to CDMS. The sensitivity, specificity, accuracy, PPV, and NPV were 78%, 83%, 64%, 89%, and 69%, respectively, for the McDonald 2010 criteria, and 67%, 96%, 77%, 96%, and 62% for the MAGNIMS 2016 MRI criteria. MAGNIMS 2016 MRI criteria were superior to McDonald 2010 MRI criteria in specificity, accuracy, and PPV, but inferior in sensitivity and NPV. Copyright © 2018 Korean Neurological Association.

  6. Diffusion-Weighted Magnetic Resonance Imaging Early After Chemoradiotherapy to Monitor Treatment Response in Head-and-Neck Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Vandecaveye, Vincent, E-mail: Vincent.Vandecaveye@uzleuven.be [Department of Radiology, University Hospitals Leuven (Belgium); Dirix, Piet [Department of Radiation Oncology, Leuven Cancer Institute, University Hospitals Leuven (Belgium); De Keyzer, Frederik; Op de Beeck, Katya [Department of Radiology, University Hospitals Leuven (Belgium); Vander Poorten, Vincent [Department of Otorhinolaryngology, Head and Neck Surgery, University Hospitals Leuven (Belgium); Hauben, Esther [Department of Pathology, University Hospitals Leuven (Belgium); Lambrecht, Maarten; Nuyts, Sandra [Department of Radiation Oncology, Leuven Cancer Institute, University Hospitals Leuven (Belgium); Hermans, Robert [Department of Radiology, University Hospitals Leuven (Belgium)

    2012-03-01

    Purpose: To evaluate diffusion-weighted imaging (DWI) for assessment of treatment response in head and neck squamous cell carcinoma (HNSCC) three weeks after the end of chemoradiotherapy (CRT). Methods and Materials: Twenty-nine patients with HNSCC underwent magnetic resonance imaging (MRI) prior to and 3 weeks after CRT, including T{sub 2}-weighted and pre- and postcontrast T{sub 1}-weighted sequences and an echo-planar DWI sequence with six b values (0 to 1,000 s/mm{sup 2}), from which the apparent diffusion coefficient (ADC) was calculated. ADC changes 3 weeks posttreatment compared to baseline ( Increment ADC) between responding and nonresponding primary lesions and adenopathies were correlated with 2 years locoregional control and compared with a Mann-Whitney test. In a blinded manner, the Increment ADC was compared to conventional MRI 3 weeks post-CRT and the routinely implemented CT, on average 3 months post-CRT, which used size-related and morphological criteria. Positive and negative predictive values (PPV and NPV, respectively) were compared between the Increment ADC and anatomical imaging. Results: The Increment ADC of lesions with later tumor recurrence was significantly lower than lesions with complete remission for both primary lesions (-2.3% {+-} 0.3% vs. 80% {+-} 41%; p < 0.0001) and adenopathies (19.9% {+-} 32% vs. 63% {+-} 36%; p = 0.003). The Increment ADC showed a PPV of 89% and an NPV of 100% for primary lesions and a PPV of 70% and an NPV of 96% for adenopathies per neck side. DWI improved PPV and NPV compared to anatomical imaging. Conclusion: DWI with the Increment ADC 3 weeks after concluding CRT for HNSCC allows for early assessment of treatment response.

  7. Psychiatric patient disposition agreement between the emergency physician and the psychiatry consultant.

    Science.gov (United States)

    Chakravarthy, Bharath; Menchine, Michael; Thompson, Daniel E; Rajeev, Sindhya; Santos, Barbara-Jean

    2013-01-01

    Mental illness is prevalent, disabling, and costly. Emergency department (ED) visits for mental health-related reasons are on the increase. Determine the level of agreement between emergency physicians and psychiatrists regarding psychiatric patient disposition. We conducted a prospective, observational study at a private university hospital ED from October 2008-April 2009 using a convenience sample of patients of all ages with psychiatric complaints who received formal psychiatric consultation during their ED visit. The emergency physician completed a data sheet prior to psychiatric consultation, assessing the likelihood of admission for psychiatric evaluation. We evaluated the positive predictive value (PPV) and negative predictive value (NPV) of the emergency physician admission decision for all patients before psychiatric consultation, compared with the patients' actual disposition as determined by the consulting psychiatrist. The study captured 230 subjects, 53% of whom were suicidal patients. 74% of patients were eventually admitted. The emergency physician decision to admit for inpatient psychiatric evaluation had a PPV of 87.3% (CI 81.4-91.9%) and an NPV of 66.7% (CI 52.9-78.6%) compared to the psychiatrist decision for the total sample, and a PPV of 90% (CI 82.4-95.1%) and an NPV of 69.6% (CI 47.1-86.8%) for suicidal patients. Additionally, the κ score, a measure of agreement between emergency physician disposition decision and psychiatrist disposition decision, was 0.530 (Cl 0.404-0.656). 95% of patients with an ED assessment of "definitely admit" were eventually admitted by the psychiatrist. Emergency physician disposition has a high PPV (87.3%) and a moderate NPV (66.7%) compared to psychiatrist disposition.

  8. Number of colony forming units in urine at 35–37 weeks’ gestation as predictor of the vaginal load of Group B Streptococci at birth

    DEFF Research Database (Denmark)

    Khalil, Mohammad; Bak Thorsen, Poul; Møller, Jens Kjølseth

    2018-01-01

    prophylaxis; NPV, Negative predictive value; PCR, Polymerase chain reaction; PPV, Positive predictive value Keywords Group B Streptococcus bacteriuria; Colony count; Vaginal colonization; Risk factor; Intrapartum colonization; Early-onset neonatal infection; Intrapartum antibiotic prophylaxis...... at 35-37 weeks’ gestation. Outcome was vaginal GBS colonization at birth as assessed by a semi-quantitative culture of a vaginal swab sample (negative, +1, +2, +3). Results Bacteriuria with GBS at 35-37 weeks’ gestation performed with a sensitivity of 30% concerning any degree of vaginal GBS...... colonization at birth (31 of 104 cases); 19% for light (+1), 17% for medium (+2), and 52% for high load (+3) vaginal GBS colonization. The colony count in case of GBS bacteriuria at 35-37 weeks’ gestation performed with positive predictive values of 35% for 104 CFU...

  9. The value of FDG-PET in diagnosing peritoneal seeding of colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Eun; Moon, Sun Mi; Cheon, Gi Jeong; Choi, Chang Woon; Hwang, Dae Yong; Lim, Sang Moo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2004-07-01

    Peritoneal seeding of colon cancer cells is a common cause of morbidity and eventual mortality with recurrent disease. This study evaluated the role of F -18 FDG PET in detecting peritoneal seeding in colorectal carcinoma (CRC and to identify characteristic patterns of abdominal F-18 FDG uptake. We reviewed the FDG PET and CT images and clinical charts of 49 patients with peritoneal seeding and 22 cancer patients without peritoneal seeding. We also assessed FDG PET scans from 20 healthy volunteers as a baseline study. The maximum standardised uptake values (SUVmax) over peritoneal lesions in cancer patients and over the area of most intense intestinal uptake in healthy volunteers and cancer patients without peritoneal carcinomatosis were measured. The result were correlated with either biopsy or ascitic aspirate. The characteristics of FDG uptake were evaluated: overall pattern (focal or diffuse), heterogeneity (yes or none), intensity (low, or equal, faint to moderate, intense). The sensitivity and positive predictive value (PPV) of FDG PET were superior to CT for the detection of peritoneal lesions (sensitivity: 71.4% vs 57.1%, specificity: 72.7% vs 54.5%: PPV: 85.4% vs 73.7%, NPV: 53.3 % vs 36.4% ). The FDG uptake in patients with peritoneal carcinomatosis was divided into nodular(14), diffuse (23) and mixed pattern (12). An SUVmax threshold of 5.2 produced a diagnostic accuracy of FDG PET of 78%. The additional information provided by FDG PET allowed a more accurate diagnosis in 12 patients (24 %), and led to alteration of the therapeutic strategy in 6 (12.2%) of the enrolled patients (n=49) with peritoneal seeding. FDG-PET was more sensitive than CT for the detection of peritoneal seeding in CRC, and altered patient management. Thus, the application of PET may be beneficial to the management of peritoneal seeding in patient with CRC.

  10. The value of FDG-PET in diagnosing peritoneal seeding of colorectal cancer

    International Nuclear Information System (INIS)

    Kim, Sung Eun; Moon, Sun Mi; Cheon, Gi Jeong; Choi, Chang Woon; Hwang, Dae Yong; Lim, Sang Moo

    2004-01-01

    Peritoneal seeding of colon cancer cells is a common cause of morbidity and eventual mortality with recurrent disease. This study evaluated the role of F -18 FDG PET in detecting peritoneal seeding in colorectal carcinoma (CRC and to identify characteristic patterns of abdominal F-18 FDG uptake. We reviewed the FDG PET and CT images and clinical charts of 49 patients with peritoneal seeding and 22 cancer patients without peritoneal seeding. We also assessed FDG PET scans from 20 healthy volunteers as a baseline study. The maximum standardised uptake values (SUVmax) over peritoneal lesions in cancer patients and over the area of most intense intestinal uptake in healthy volunteers and cancer patients without peritoneal carcinomatosis were measured. The result were correlated with either biopsy or ascitic aspirate. The characteristics of FDG uptake were evaluated: overall pattern (focal or diffuse), heterogeneity (yes or none), intensity (low, or equal, faint to moderate, intense). The sensitivity and positive predictive value (PPV) of FDG PET were superior to CT for the detection of peritoneal lesions (sensitivity: 71.4% vs 57.1%, specificity: 72.7% vs 54.5%: PPV: 85.4% vs 73.7%, NPV: 53.3 % vs 36.4% ). The FDG uptake in patients with peritoneal carcinomatosis was divided into nodular(14), diffuse (23) and mixed pattern (12). An SUVmax threshold of 5.2 produced a diagnostic accuracy of FDG PET of 78%. The additional information provided by FDG PET allowed a more accurate diagnosis in 12 patients (24 %), and led to alteration of the therapeutic strategy in 6 (12.2%) of the enrolled patients (n=49) with peritoneal seeding. FDG-PET was more sensitive than CT for the detection of peritoneal seeding in CRC, and altered patient management. Thus, the application of PET may be beneficial to the management of peritoneal seeding in patient with CRC

  11. Modeling Polio Data Using the First Order Non-Negative Integer-Valued Autoregressive, INAR(1), Model

    Science.gov (United States)

    Vazifedan, Turaj; Shitan, Mahendran

    Time series data may consists of counts, such as the number of road accidents, the number of patients in a certain hospital, the number of customers waiting for service at a certain time and etc. When the value of the observations are large it is usual to use Gaussian Autoregressive Moving Average (ARMA) process to model the time series. However if the observed counts are small, it is not appropriate to use ARMA process to model the observed phenomenon. In such cases we need to model the time series data by using Non-Negative Integer valued Autoregressive (INAR) process. The modeling of counts data is based on the binomial thinning operator. In this paper we illustrate the modeling of counts data using the monthly number of Poliomyelitis data in United States between January 1970 until December 1983. We applied the AR(1), Poisson regression model and INAR(1) model and the suitability of these models were assessed by using the Index of Agreement(I.A.). We found that INAR(1) model is more appropriate in the sense it had a better I.A. and it is natural since the data are counts.

  12. Follow-up of recurrences of limb soft tissue sarcomas in patients with localized disease: performance of ultrasound

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Truini, Mauro; Spina, Bruno; Cambiaso, Paolo; Zaottini, Federico; Bignotti, Bianca; Derchi, Lorenzo E.; Martinoli, Carlo; Calabrese, Massimo

    2015-01-01

    To evaluate diagnostic performance of ultrasound in the detection of local recurrences in patients with localized soft tissue sarcomas of the limb. An analysis of patients treated for soft tissue sarcomas between 2005 and April 2014 was performed. Sixty-eight patients (men/women, 36:32; age range, 18-84 years) were evaluated. Sensitivity, specificity with 95 % confidence intervals (CIs), positive predictive value (PPV), pre-test probability (the prevalence), negative predictive value (NPV), likelihood ratio for positive results (LH+), accuracy and post-test probability (post-P) of ultrasound were reported on a per patient basis using surgical findings and clinical follow-up as reference standard. Effects of independent variables (US equipment, age and sex, body mass index, radiologist) were considered. Comparison with MR was also performed. The overall sensitivity and specificity were 0.88 (0.60-0.94) and 0.94 (0.86-0.98). PPV, pre-test probability, NPV, LH+, accuracy and post-P: 0.83/0.25/0.96/14.9/0.92/0.83. There were two false negative cases both graded as G3 and deeply located and three false positive US cases. Diagnostic accuracy was not dependent by US machine (p = 0.08), age and sex (p = 0.16), body mass index (p = 0.07) and radiologists (p = 0.07). Diagnostic accuracy of ultrasound was relatively high. Negative US results excluded the presence of a local recurrence with acceptable accuracy. (orig.)

  13. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    Science.gov (United States)

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  14. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  15. Validation of asthma recording in electronic health records: a systematic review

    Directory of Open Access Journals (Sweden)

    Nissen F

    2017-12-01

    Full Text Available Francis Nissen,1 Jennifer K Quint,2 Samantha Wilkinson,1 Hana Mullerova,3 Liam Smeeth,1 Ian J Douglas1 1Department of Non-Communicable Disease Epidemiology, London School of Hygiene and Tropical Medicine, London, UK; 2National Heart and Lung Institute, Imperial College, London, UK; 3RWD & Epidemiology, GSK R&D, Uxbridge, UK Objective: To describe the methods used to validate asthma diagnoses in electronic health records and summarize the results of the validation studies. Background: Electronic health records are increasingly being used for research on asthma to inform health services and health policy. Validation of the recording of asthma diagnoses in electronic health records is essential to use these databases for credible epidemiological asthma research.Methods: We searched EMBASE and MEDLINE databases for studies that validated asthma diagnoses detected in electronic health records up to October 2016. Two reviewers independently assessed the full text against the predetermined inclusion criteria. Key data including author, year, data source, case definitions, reference standard, and validation statistics (including sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV] were summarized in two tables.Results: Thirteen studies met the inclusion criteria. Most studies demonstrated a high validity using at least one case definition (PPV >80%. Ten studies used a manual validation as the reference standard; each had at least one case definition with a PPV of at least 63%, up to 100%. We also found two studies using a second independent database to validate asthma diagnoses. The PPVs of the best performing case definitions ranged from 46% to 58%. We found one study which used a questionnaire as the reference standard to validate a database case definition; the PPV of the case definition algorithm in this study was 89%. Conclusion: Attaining high PPVs (>80% is possible using each of the discussed validation

  16. Quantitative contrast-enhanced harmonic EUS in differential diagnosis of focal pancreatic masses (with videos)

    DEFF Research Database (Denmark)

    Săftoiu, Adrian; Vilmann, Peter; Dietrich, Christoph F

    2015-01-01

    BACKGROUND: The role of EUS with contrast agents can be expanded through the use of time-intensity curve (TIC) analysis and computer-aided interpretation. OBJECTIVE: To validate the use of parameters derived from TIC analysis in an artificial neural network (ANN) classification model designed......-guided FNA (EUS-FNA), TIC analysis, and ANN processing. MAIN OUTCOME MEASUREMENTS: Sensitivity, specificity, positive and negative predictive values (PPV, NPV) for EUS-FNA, CEH-EUS, and the ANN. RESULTS: After excluding all of the recordings that did not meet the technical and procedural criteria, 112 cases...... rise time, mean transit time, and time to peak. For the ANN, sensitivity was 94.64%, specificity 94.44%, PPV 97.24%, and NPV 89.47%. LIMITATIONS: Only PC and CP lesions were included. CONCLUSION: Parameters obtained through TIC analysis can differentiate between PC and CP cases and can be used...

  17. Positive predictive value of a register-based algorithm using the Danish National Registries to identify suicidal events.

    Science.gov (United States)

    Gasse, Christiane; Danielsen, Andreas Aalkjaer; Pedersen, Marianne Giørtz; Pedersen, Carsten Bøcker; Mors, Ole; Christensen, Jakob

    2018-04-17

    It is not possible to fully assess intention of self-harm and suicidal events using information from administrative databases. We conducted a validation study of intention of suicide attempts/self-harm contacts identified by a commonly applied Danish register-based algorithm (DK-algorithm) based on hospital discharge diagnosis and emergency room contacts. Of all 101 530 people identified with an incident suicide attempt/self-harm contact at Danish hospitals between 1995 and 2012 using the DK-algorithm, we selected a random sample of 475 people. We validated the DK-algorithm against medical records applying the definitions and terminology of the Columbia Classification Algorithm of Suicide Assessment of suicidal events, nonsuicidal events, and indeterminate or potentially suicidal events. We calculated positive predictive values (PPVs) of the DK-algorithm to identify suicidal events overall, by gender, age groups, and calendar time. We retrieved medical records for 357 (75%) people. The PPV of the DK-algorithm to identify suicidal events was 51.5% (95% CI: 46.4-56.7) overall, 42.7% (95% CI: 35.2-50.5) in males, and 58.5% (95% CI: 51.6-65.1) in females. The PPV varied further across age groups and calendar time. After excluding cases identified via the DK-algorithm by unspecific codes of intoxications and injury, the PPV improved slightly (56.8% [95% CI: 50.0-63.4]). The DK-algorithm can reliably identify self-harm with suicidal intention in 52% of the identified cases of suicide attempts/self-harm. The PPVs could be used for quantitative bias analysis and implemented as weights in future studies to estimate the proportion of suicidal events among cases identified via the DK-algorithm. Copyright © 2018 John Wiley & Sons, Ltd.

  18. The prognostic value of oncogenic antigen 519 (OA-519) expression and proliferative activity detected by antibody MIB-1 in node-negative breast cancer

    DEFF Research Database (Denmark)

    Jensen, V; Ladekarl, M; Holm-Nielsen, P

    1995-01-01

    The prognostic value of oncogenic antigen 519 (OA-519) expression and tumour proliferative activity was evaluated in a retrospective series of 118 patients with low-risk breast cancer. Low risk was defined as negative axillary nodes, tumour diameter histological evidence...... analysis, both the MIB-1 index and OA-519 expression were of independent prognostic value (2p breast cancer who might benefit from adjuvant therapy....

  19. Renal scintigraphy with DMSA 99 mTc and the direct radionuclide cystogram in children with recurrent urinary tract infections

    International Nuclear Information System (INIS)

    Donoso R, Gilda; Lobo S, Gabriel; Arteaga V, Maria de la Paz; Arnello V, Francisca; Jimenez, Cesar; Perez, Andres

    2003-01-01

    The aim of this study was to correlate the results of Renal Scintigraphy (RS) and the Direct Radionuclide Cystogram (DRC) in children with recurrent urinary tract infections. Method: we analyse 92 children, 82 % females , with ages ranging from 1 month- 12 years old (mean:4,3 years old). Both techniques were performed conventionally with a gammacamera/ computer system. We determined the concordance or discordance between them, and the positive and negative predictive value (PPV, NPV ) of one method with respect the other. For statistical analysis we use Chi square and MacNemar test. Results: 45 % of the RS were abnormal, and the 27 % of DRC was positive. We found a concordance of the results in both techniques in 70 % (p< 0.001) .For the RS vs DRC the PPV was 46% and the NPV was 88%. For the DRC vs RS the PPV was the 76 % and the NPV was 67%. Conclusions. 1.- : 1.- the normality of RS is a better predictor of normality than DRC. 2.-The abnormality of DRC predicts better the abnormality of RS than the inverse. 3.- The results of both techniques show a significant concordance (author)

  20. Multifractal structure of multiplicity distributions and negative binomials

    International Nuclear Information System (INIS)

    Malik, S.; Delhi, Univ.

    1997-01-01

    The paper presents experimental results of the multifractal structure analysis in proton-emulsion interactions at 800 GeV. The multiplicity moments have a power law dependence on the mean multiplicity in varying bin sizes of pseudorapidity. The values of generalised dimensions are calculated from the slope value. The multifractal characteristics are also examined in the light of negative binomials. The observed multiplicity moments and those derived from the negative-binomial fits agree well with each other. Also the values of D q , both observed and derived from the negative-binomial fits not only decrease with q typifying multifractality but also agree well each other showing consistency with the negative-binomial form

  1. Validation and optimisation of an ICD-10-coded case definition for sepsis using administrative health data

    Science.gov (United States)

    Jolley, Rachel J; Jetté, Nathalie; Sawka, Keri Jo; Diep, Lucy; Goliath, Jade; Roberts, Derek J; Yipp, Bryan G; Doig, Christopher J

    2015-01-01

    Objective Administrative health data are important for health services and outcomes research. We optimised and validated in intensive care unit (ICU) patients an International Classification of Disease (ICD)-coded case definition for sepsis, and compared this with an existing definition. We also assessed the definition's performance in non-ICU (ward) patients. Setting and participants All adults (aged ≥18 years) admitted to a multisystem ICU with general medicosurgical ICU care from one of three tertiary care centres in the Calgary region in Alberta, Canada, between 1 January 2009 and 31 December 2012 were included. Research design Patient medical records were randomly selected and linked to the discharge abstract database. In ICU patients, we validated the Canadian Institute for Health Information (CIHI) ICD-10-CA (Canadian Revision)-coded definition for sepsis and severe sepsis against a reference standard medical chart review, and optimised this algorithm through examination of other conditions apparent in sepsis. Measures Sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were calculated. Results Sepsis was present in 604 of 1001 ICU patients (60.4%). The CIHI ICD-10-CA-coded definition for sepsis had Sn (46.4%), Sp (98.7%), PPV (98.2%) and NPV (54.7%); and for severe sepsis had Sn (47.2%), Sp (97.5%), PPV (95.3%) and NPV (63.2%). The optimised ICD-coded algorithm for sepsis increased Sn by 25.5% and NPV by 11.9% with slightly lowered Sp (85.4%) and PPV (88.2%). For severe sepsis both Sn (65.1%) and NPV (70.1%) increased, while Sp (88.2%) and PPV (85.6%) decreased slightly. Conclusions This study demonstrates that sepsis is highly undercoded in administrative data, thus under-ascertaining the true incidence of sepsis. The optimised ICD-coded definition has a higher validity with higher Sn and should be preferentially considered if used for surveillance purposes. PMID:26700284

  2. Synthesis and characterization of a magnetic adsorbent from negatively-valued iron mud for methylene blue adsorption

    Science.gov (United States)

    Liu, Jiancong; Yu, Yang; Yang, Jiakuan; Song, Jian; Fan, Wei; Yu, Hongbin; Bian, Dejun; Huo, Mingxin

    2018-01-01

    With increasing awareness of reduction of energy and CO2 footprint, more waste is considered recyclable for generating value-added products. Here we reported the negatively-valued iron mud, a waste from groundwater treatment plant, was successfully converted into magnetic adsorbent. Comparing with the conventional calcination method under the high temperature and pressure, the synthesis of the magnetic particles (MPs) by Fe2+/Fe3+ coprecipitation was conducted at environment-friendly condition using ascorbic acid (H2A) as reduction reagent and nitric acid (or acid wastewater) as leaching solution. The MPs with major component of Fe3O4 were synthesized at the molar ratio (called ratio subsequently) of H2A to Fe3+ of iron mud ≥ 0.1; while amorphous ferrihydrite phase was formed at the ratio ≤ 0.05, which were confirmed by vibrating sample magnetometer (VSM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). With the ratio increased, the crystalline size and the crystallization degree of MPs increased, and thus the Brunauer-Emmett-Teller (BET) surface and the cation-exchange capacity (CEC) decreased. MPs-3 prepared with H2A to Fe3+ ratio of 0.1 demonstrated the highest methylene blue (MB) adsorption of 87.3 mg/g and good magnetic response. The adsorption of MB onto MPs agreed well with the non-linear Langmuir isotherm model and the pseudo-second-order model. Pilot-scale experiment showed that 99% of MB was removed by adding 10 g/L of MPs-3. After five adsorption-desorption cycles, MPs-3 still showed 62% removal efficiency for MB adsorption. When nitric acid was replaced by acid wastewater from a propylene plant, the synthesized MPs-3w showed 3.7 emu/g of saturation magnetization (Ms) and 56.7 mg/g of MB adsorption capacity, 2.8 times of the widely used commercial adsorbent of granular active carbon (GAC). The major mechanism of MPs adsorption for MB was electrostatic attraction and cation exchange. This study synthesized a magnetic adsorbent from

  3. Grading of Cerebral Glioma with Multiparametric MR Imaging and {sup 18}F-FDG-PET: Concordance and Accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Kim, Ji-hoon; Sohn, Chul-Ho; Choi, Seung Hong; Yun, Tae Jin; Song, Yong Sub [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Kang, Won Jun [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Yonsei University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Eun, Yong [Seoul National University, College of Medicine, Seoul (Korea, Republic of); Chang, Kee-Hyun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Soonchunhyang University Bucheon Hospital, Department of Radiology, Bucheon (Korea, Republic of)

    2014-02-15

    To retrospectively evaluate concordance rates and predictive values in concordant cases among multiparametric MR techniques and FDG-PET to grade cerebral gliomas. Multiparametric MR imaging and FDG-PET were performed in 60 consecutive patients with cerebral gliomas (12 low-grade and 48 high-grade gliomas). As the dichotomic variables, conventional MRI, minimum apparent diffusion coefficient in diffusion-weighted imaging, maximum relative cerebral blood volume ratio in perfusion-weighted imaging, choline/creatine ratio and (lipid and lactate)/creatine ratio in MR spectroscopy, and maximum standardised uptake value ratio in FDG-PET in low- and high-grade gliomas were compared. Their concordance rates and positive/negative predictive values (PPV/NPV) in concordant cases were obtained for the various combinations of multiparametric MR techniques and FDG-PET. There were significant differences between low- and high-grade gliomas in all techniques. Combinations of two, three, four, and five out of the five techniques showed concordance rates of 77.0 ± 4.8 %, 65.5 ± 4.0 %, 58.3 ± 2.6 % and 53.3 %, PPV in high-grade concordant cases of 97.3 ± 1.7 %, 99.1 ± 1.4 %, 100.0 ± 0 % and 100.0 % and NPV in low-grade concordant cases of 70.2 ± 7.5 %, 78.0 ± 6.0 %, 80.3 ± 3.4 % and 80.0 %, respectively. Multiparametric MR techniques and FDG-PET have a concordant tendency in a two-tiered classification for the grading of cerebral glioma. If at least two examinations concordantly indicated high-grade gliomas, the PPV was about 95 %. (orig.)

  4. Post-treatment PET/CT and p16 status for predicting treatment outcomes in locally advanced head and neck cancer after definitive radiation

    Energy Technology Data Exchange (ETDEWEB)

    Awan, Musaddiq J.; Machtay, Mitchell; Yao, Min [Case Western Reserve University and University Hospitals, Department of Radiation Oncology, Cleveland, OH (United States); Lavertu, Pierre; Zender, Chad; Rezaee, Rod; Fowler, Nicole [University Hospitals, Department of Otolaryngology and Head and Neck Surgery, Cleveland, OH (United States); Karapetyan, Lilit; Gibson, Michael [University Hospitals, Department of Medical Oncology, Cleveland, OH (United States); Wasman, Jay [University Hospitals, Department of Pathology, Cleveland, OH (United States); Faulhaber, Peter [University Hospitals, Department of Nuclear Medicine and Radiology, Cleveland, OH (United States)

    2017-06-15

    To retrospectively review post-treatment (post-tx) FDG-PET/CT scans in patients with advanced head and neck squamous cell carcinoma (HNSCC) and known p16 status, treated with definitive (chemo)radiation (RT). A total of 108 eligible patients had N2A or greater HNSCC treated with chemoRT from August 1, 2008, to February 28, 2015, with post-tx PET/CT within 6 months after RT. Kaplan-Meier curves, log-rank statistics, and Cox proportional hazards regression were used for statistical analysis. Median follow-up was 2.38 years. Sixty-eight (63.0%) patients had p16+ and 40 (37.0%) had p16- status. Two-year overall survival and recurrence-free survival were 93.4% and 77.8%, respectively. The negative predictive value (NPV) of PET/CT for local recurrence (LR) was 100%. The NPV for regional recurrence (RR) was 96.5% for all patients, 100% for p16+ patients, and 88.5% for p16- patients. The positive predictive value (PPV) of PET/CT for recurrence was 77.3% for all patients, 50.0% for p16+, and 78.6% for p16-. The PPV for LR was 72.7% for all patients, 50.0% for p16+ patients, and 72.7% for p16- patients. The PPV for RR was 50.0% for all patients, 33% for p16+, and 66.6% for p16-. Post-tx PET/CT and p16 status were independent predictors of recurrence-free survival (p < 0.01). Post-tx PET/CT predicts treatment outcomes in both p16 + and p16- patients, and does so independently of p16 status. P16- patients with negative PET have a 10% risk of nodal recurrence, and closer follow-up in these patients is warranted. (orig.)

  5. Validation of an Arab name algorithm in the determination of Arab ancestry for use in health research.

    Science.gov (United States)

    El-Sayed, Abdulrahman M; Lauderdale, Diane S; Galea, Sandro

    2010-12-01

    Data about Arab-Americans, a growing ethnic minority, are not routinely collected in vital statistics, registry, or administrative data in the USA. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically based probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. We used data from all Michigan birth certificates between 2000 and 2005. Fathers' surnames and mothers' maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Statewide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and an NPV of 98.6%. Both the false-positive and false-negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false-positive rate increased and false-negative rate decreased. The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA.

  6. Comparative evaluation of sonographic ovarian morphology of Indian women with polycystic ovary syndrome versus those of normal women

    Directory of Open Access Journals (Sweden)

    Sanjeed Ahmed

    2014-01-01

    Full Text Available Objectives: To study ovarian morphology by ultrasound in women with or without polycystic ovary syndrome (PCOS and to establish cut-off values of these parameters in Indian women with PCOS. Materials and Methods: A total of 119 consecutive women diagnosed PCOS and 77 apparently healthy women were enrolled. Transabdominal ultrasound examination was carried out to assess ovarian volume, stromal echogenecity, follicle number and size. Cut-off values of the above ovarian parameters with sensitivity, specificity, positive predictive value (PPV and negative predictive values (NPV were calculated. Results: Sensitivity of 79.49% and specificity of 90.67% was achieved with a cut-off of 8 mL as ovarian volume. A cut-off value of 9 follicles to distinguish between PCOS and control women yielded a sensitivity of 82.35% and specificity of 92.0% while as a follicular size of 5 mm yielded sensitivity and specificity of 74.67% and 78.15% respectively. With all the three parameters sensitivity was 87.39% and specificity 87.84% with 92.04% PPV and 81.25% NPV. Conclusion: Using two or three sonographic criteria in combination improves sensitivity and helps diagnose additional patients with PCOS. Our results are at variance with the established cut-off values highlighting the fact that American Society for Reproductive Medicine consensus cut-off values are not reproducible in Indian context.

  7. Evaluation of insulin-like growth factor-1 and insulin like growth factor binding protein-3 in diagnosis of growth hormone deficiency in short-stature children

    International Nuclear Information System (INIS)

    Ali, A.; Hashim, R.; Khan, F.A.; Sattar, A.; Ijaz, A.; Manzoor, S.M.; Younas, M.

    2009-01-01

    Growth Hormone Deficiency (GHD) is conventionally diagnosed and confirmed by diminished peak Growth Hormone (GH) levels to provocative testing. Serum Insulin-like growth factor-1 (IGF-1) and insulin-like growth factor binding protein-3 (IGFBP-3) are under the influence of GH and reflect the spontaneous endogenous GH secretion. Owing to the absence of a circadian rhythm, it is possible to take individual measurements of IGF-1 and IGFBP-3 at any time of the day for evaluation of GH status instead of subjecting the individual to cumbersome provocative tests. Objectives of this study were to compare IGF-1 and IGFBP-3 assays with Exercise and L-Dopa stimulation tests in the diagnosis of growth hormone deficiency in short stature children using ITT as gold standard. Methods: This validation study was conducted at Department of Chemical Pathology and Endocrinology, AFIP, Rawalpindi, from November 2005 to October 2006. Fifty-two short stature children were included in the study. Basal samples for GH levels and simultaneous IGF-1 and IGFBP-3 measurements were obtained and afterwards all children were subjected to sequential exercise and LDopa stimulation tests. Insulin Tolerance Test (ITT) was performed one week later with all the necessary precautionary measures. On the basis of ITT results, children were divided into two groups, i.e., 31 growth hormone deficient and 21 Normal Variant Short Stature (NVSS). Results: The diagnostic value of exercise stimulation test remained highest with sensitivity 90.3%, specificity 76.0%, Positive Predictive Value (PPV) 84.84%, Negative Predictive Value (NPV) 84.2% and accuracy 84.6%. The conventional L-Dopa stimulation had sensitivity 96.7%, specificity 38.0%, PPV 69.7%, NPV 88.8 % and accuracy 73.0%. The serum IGF-1 and IGFBP-3 levels were positively correlated with post ITT peak GH levels (r= 0.527, r=0.464 respectively, both p<0.001). The diagnostic value of IGF-1 had sensitivity 83.87%, specificity 76.2%, PPV 83.87%, NPV 76.2% and

  8. Prognostic value of negative interim 2-["1"8F]-fluoro-2-deoxy-D-glucose PET/CT in diffuse large B-cell lymphoma

    International Nuclear Information System (INIS)

    Kwon, S.H.; Kang, D.R.; Kim, J.; Yoon, J.-K.; Lee, S.J.; Jeong, S.H.; Lee, H.W.; An, Y.-S.

    2016-01-01

    Aim: To assess the prognostic value of negative interim combined 2-["1"8F]-fluoro-2-deoxy-D-glucose ("1"8F-FDG) positron-emission tomography/computed tomography (PET/CT) in patients with diffuse large B-cell lymphoma (DLBCL). Materials and methods: Ninety-two patients with histologically proven DLBCL were enrolled. All of the patients underwent "1"8F-FDG PET/CT at diagnosis, and interim PET/CT after the second cycle of chemotherapy with rituximab, cyclophosphamide, hydroxydaunorubicin, vincristine, and prednisolone (R-CHOP). Negative interim PET/CT was defined as the disappearance of all abnormal "1"8F-FDG uptake compared to the pretreatment PET/CT image, as determined by visual assessment. The clinical outcome of patients was estimated as progression-free survival (PFS), and the prognostic significance of clinicopathological and imaging parameters were assessed using the Cox proportional hazards model. Results: Thirty-six patients (39.1%) showed lymphoma progression within a median follow-up of 30.8 months. According to univariate analysis, Ann Arbor stage, serum lactate dehydrogenase level, Eastern Cooperative Oncology Group scale, International Prognostic Index (IPI) score, and maximum standardised uptake values on initial PET/CT were significant prognostic factors for PFS (all p<0.05). Among these parameters, only the IPI score was an independent predictor for PFS (p=0.044). Survival of patients with a high IPI score (≥3) was poorer than those with a low IPI score (0–2; p<0.001). Conclusion: Despite a negative interim "1"8F-FDG PET/CT, approximately 39% of DLBCL patients showed progression during follow-up. Although the negative PET/CT was obtained during chemotherapy, it is important to closely follow-up patients, especially those with a high IPI score. - Highlights: • About 39% of patients showed progression after negative interim PET/CT. • The IPI score was an independent predictor for PFS. • It is important to closely follow-up with high IPI score

  9. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  10. T1 bright appendix sign to exclude acute appendicitis in pregnant women.

    Science.gov (United States)

    Shin, Ilah; An, Chansik; Lim, Joon Seok; Kim, Myeong-Jin; Chung, Yong Eun

    2017-08-01

    To evaluate the diagnostic value of the T1 bright appendix sign for the diagnosis of acute appendicitis in pregnant women. This retrospective study included 125 pregnant women with suspected appendicitis who underwent magnetic resonance (MR) imaging. The T1 bright appendix sign was defined as a high intensity signal filling more than half length of the appendix on T1-weighted imaging. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the T1 bright appendix sign for normal appendix identification were calculated in all patients and in those with borderline-sized appendices (6-7 mm). The T1 bright appendix sign was seen in 51% of patients with normal appendices, but only in 4.5% of patients with acute appendicitis. The overall sensitivity, specificity, PPV, and NPV of the T1 bright appendix sign for normal appendix diagnosis were 44.9%, 95.5%, 97.6%, and 30.0%, respectively. All four patients with borderline sized appendix with appendicitis showed negative T1 bright appendix sign. The T1 bright appendix sign is a specific finding for the diagnosis of a normal appendix in pregnant women with suspected acute appendicitis. • Magnetic resonance imaging is increasingly used in emergency settings. • Acute appendicitis is the most common cause of acute abdomen. • Magnetic resonance imaging is widely used in pregnant population. • T1 bright appendix sign can be a specific sign representing normal appendix.

  11. Consumer Complaints and Company Market Value

    Directory of Open Access Journals (Sweden)

    Danny Pimentel Claro

    2014-07-01

    Full Text Available Consumer complaints affect company market value and common sense suggests that a negative impact is expected. However, do complaints always negatively impact company market value? We hypothesize in this study that complaints may have a non-linear effect on market value. Positive (e.g. avoiding high costs to solve complaints and negative (e.g. speedy and intense diffusion tradeoffs may occur given the level of complaints. To test our non-linear hypothesis, a panel data was collected from cell phone service providers from 2005 to 2013. The results supported our tradeoff rationale. Low levels of complaints allow for companies to increase market value, while high levels of complaints cause increasing harm to market value. The sample, model and period considered in this study, indicates a level of 0.49 complaints per thousand consumers as the threshold for a shift in tradeoffs. The effects on market value become increasingly negative when trying to make reductions to move below this level, due to negative tradeoffs.

  12. The accuracy of clinical and biochemical estimates in defining the pre-test probability of pulmonary embolism

    International Nuclear Information System (INIS)

    Garvie, N.W.; Salehzahi, F.; Kuitert, L.

    2002-01-01

    Full text: The PIOPED survey confirmed the significance of the high probability ventilation/perfusion scan (HP V/Q scan) in establishing the diagnosis of pulmonary embolism (PE). In an interesting sentence, however, the authors indicated that 'the clinicians' assessment of the likelihood of PE (prior probability)' can substantially increase the predictive value of the investigation. The criteria used for this assessment were not published, and this statement conflicts with the belief that the clinical diagnosis of pulmonary embolism is unreliable. A medical history was obtained from 668 patients undergoing V/Q lung scans for suspected PE, and certain clinical features linked to PE were, when present, documented. These included pleuritic chest pain, haemoptysis, dyspnoea, clinical evidence of DVT, recent surgery and right ventricular strain pattern an ECG. D-Dimer levels and initial arterial oxygen saturation (PaO2) levels were also obtained. The prevalence of these clinical and biochemical criteria was then compared between HP (61) and normal (171) scans after exclusion of all equivocal or intermediate scan outcomes (436), (where lung scintigraphy was unable to provide a definite diagnosis). D-Dimer and/or oxygen saturation levels, were similarly compared in each group. A true positive result was scored for each clinical or biochemical criterion when linked with a high probability scan and, conversely, a false positive score when the scan outcome was normal. In this fashion, the positive predictive value (PPV) and, when appropriate, the negative predictive value (NPV) was obtained for each risk factor. In the context of PE, DVT and post-operative status prove the more reliable predictors of a high probability outcome. Where both features were present, the PPV rose to 0.57. A normal D-Dimer level was a better excluder of PE than a normal oxygen saturation level (NPV 0.78-v-0.44). Conversely, a raised D-Dimer, or reduced oxygen saturation, were both a little value in

  13. 111In-Pentetreotide scintigraphy in medulloblastoma: A comparison with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yueksel, Mahmut; Lutterbey, Goetz; Biersack, Hans Juergen; Elke, Urs; Ezziddin, Samer; Hasan, Carola; Bode, Udo; Zairong Gao

    2007-01-01

    Medulloblastoma (MB) is a primitive neuroectodermal tumour constituting a grade IV brain malignancy. Early and correct detection of recurrence or metastasis is desirable for follow-up of patients in this entity. Frequent expression of somatostatin receptors by MB lesions facilitates functional tumour imaging by somatostatin receptor scintigraphy (SRS). To investigate the value of SRS in the follow-up of MB, the results of ten consecutive patients (seven children and three adults) undergoing additional imaging with 111 In-pentetreotide were reviewed. Four, 24 and 48 h p.i. planar and whole body images as well as a SPECT study at 4 h p.i. were acquired after intravenous injection of 109±35 MBq 111 In-pentetreotide (Octreoscan). SRS yielded 11 positive and ten negative imaging results, compared to 17 positive and four negative in magnetic resonance imaging (MRI). The lesion-by-lesion analysis with a total of 44 lesions revealed a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 42%, 83%, 94%, 18% for SRS and 89.5%, 50%, 92%, 43% for MRI. Based on a per-patient analysis, considering the patient as to be either tumour-free or tumour-positive by one imaging modality, the following values for sensitivity, specificity, PPV and NPV were obtained: 61%, 100%, 100%, 30% for SRS and 94%, 67%, 94%, 67% for MRI. MRI remains the first step imaging technique in medulloblastoma patients before and after surgery and during the follow-up providing the highest sensitivity. However, to improve specificity and contribute to correct diagnosis in MB 111 In-pentetreotide scintigraphy should be considered as a confirmatory second step imaging tool, especially in case of equivocal MRI results. Moreover, a positive SRS scan might serve as a reference before and after somatostatin receptor targeted radiotherapy

  14. Accuracy of contrast-enhanced dual-energy MDCT for the assessment of iodine uptake in renal lesions.

    Science.gov (United States)

    Mileto, Achille; Marin, Daniele; Ramirez-Giraldo, Juan Carlos; Scribano, Emanuele; Krauss, Bernhard; Mazziotti, Silvio; Ascenti, Giorgio

    2014-05-01

    The objective of our study was to assess the accuracy of iodine-related attenuation and iodine quantification as imaging biomarkers of iodine uptake in renal lesions on a single-phase nephrographic image with dual-energy MDCT. Fifty-nine patients (41 men, 18 women; age range, 28-84 years) with 80 renal lesions underwent contrast-enhanced dual-energy CT during the nephrographic phase of enhancement. Renal lesions were characterized as enhancing or nonenhancing on color-coded iodine overlay maps using iodine-related attenuation (in Hounsfield units) and iodine quantification (in milligrams per milliliter). For iodine-related attenuation the iodine uptake thresholds of 15 and 20 HU were tested; a threshold of 0.5 mg/mL was used for iodine quantification. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of iodine-related attenuation and iodine quantification were calculated from chi-square tests of contingency with histopathology or imaging follow-up as the reference standard. The 95% CIs were calculated from binomial expression. Differences in sensitivity and specificity were assessed by means of McNemar analysis. A significant difference in sensitivity and specificity was found between iodine-related attenuation with the thresholds of 15 HU (sensitivity, 91.4%; specificity, 93.3%; PPV, 91.4%; NPV, 93.3%) and 20 HU (sensitivity, 77.1%; specificity, 100%; PPV, 100%; NPV, 84.9%) (p = 0.008) and between iodine quantification (sensitivity, 100%; specificity, 97.7%; PPV, 97.2%; NPV, 100%) and iodine-related attenuation with a threshold of 20 HU (p = 0.004). No significant difference in sensitivity and specificity was found between iodine quantification and iodine-related attenuation with a threshold of 15 HU. Contrast-enhanced dual-energy MDCT with iodine-related attenuation and iodine quantification allows accurate evaluation of iodine uptake in renal lesions on a single-phase nephrographic image.

  15. Both semiquantitative degree of rest Tl-201 uptake and reversibility at 24 hour-delay were needed to predict wall motion improvement after bypass surgery

    International Nuclear Information System (INIS)

    Lee, D. S.; Yoon, S. N.; Kim, K. B.; Jeong, Z. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Controversy still exists about how to use the uptake at rest and 24 hour delay in rest redistribution Tl-201 SPECT to predict improvement of wall motion abnormality after bypass surgery. To find the best way to combine diagnostic efficacy of Tl-201 SPECT to predict myocardial viability, we studied the predictive values (positive: PPV, negative: NPV) of rest and 24 hour-delay Tl-201 SPECT in 21 patients. Wall motion was assessed comparing preoperative post-stress gated Tc-99m-MIBI SPECT with that of 3 months after surgery. Four point scoring system was used for 17 myocardial segments to asses uptakes ( 0 to 3 for normal to defect) at rest and 24 hour-delay and wall motion ( 0 to 3 for normal to dyskinesia). Ejection fraction improved after surgery (5011% vs 4313%). Intra-observer and inter-observer reproducibility of EF was 7 and 9% respectively when we used 3D Perfusion-Motion Map. Sixty seven segments showed wall motion abnormality before surgery. Predictive values of rest Tl-201 uptake decrease were as follows: 0: 15/15(100%), 1: 30/34(88%), 2: 6/11 (55%), 3: 3/7(43%). So PPV of mild decrease was 88%, and NPV of severe decrease was 50%. Delayed reversibility was evaluated in 37 segments (15 patients). Twenty seven segment had persistence or aggravation, but the other 10 segments improved at 24 hour delay. PPV of reversible 10 segments was 80%, and NPV of reversibility was only 46%. PPV of combination of rest Tl-201 uptake of mild degree and 24 hour reversibility was 86% (38/44) and NPV of neither one was 88%. We concluded that both semi-quantitative degree of Tl-201 uptake at rest and reversibility at 24 hour delay was the best to warrant or abandon postoperative improvement of abnormal wall motion found at preoperative post-stress gated myocardial SPECT

  16. Screening for Underage Drinking and Diagnostic and Statistical Manual of Mental Disorders, 5th Edition Alcohol Use Disorder in Rural Primary Care Practice.

    Science.gov (United States)

    Clark, Duncan B; Martin, Christopher S; Chung, Tammy; Gordon, Adam J; Fiorentino, Lisa; Tootell, Mason; Rubio, Doris M

    2016-06-01

    To examine the National Institute on Alcohol Abuse and Alcoholism Youth Guide alcohol frequency screening thresholds when applied to Diagnostic and Statistical Manual of Mental Disorders, 5th Edition (DSM-5) diagnostic criteria, and to describe alcohol use patterns and alcohol use disorder (AUD) characteristics in rural youth from primary care settings. Adolescents (n = 1193; ages 12 through 20 years) visiting their primary care practitioner for outpatient visits in six rural primary care clinics were assessed prior to their practitioner visit. A tablet computer collected youth self-report of past-year frequency and quantity of alcohol use and DSM-5 AUD symptoms. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined. For early adolescents (ages 12 through 14 years), 1.9% met DSM-5 criteria for past-year AUD and ≥3 days with alcohol use in the past year yielded a screen for DSM-5 with optimal psychometric properties (sensitivity: 89%; specificity: 95%; PPV: 37%; NPV: 100%). For middle adolescents (ages 15 through 17 years), 9.5% met DSM-5 AUD criteria, and ≥3 past year drinking days showed optimal screening results (sensitivity: 91%; specificity: 89%; PPV: 50%; NPV: 99%). For late adolescents (ages 18 through 20 years), 10.0% met DSM-5 AUD criteria, and ≥12 past year drinking days showed optimal screening results (sensitivity: 92%; specificity: 75%; PPV: 31%; NPV: 99%). The age stratified National Institute on Alcohol Abuse and Alcoholism frequency thresholds also produced effective results. In rural primary care clinics, 10% of youth over age 14 years had a past-year DSM-5 AUD. These at-risk adolescents can be identified with a single question on alcohol use frequency. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Clinical value of whole-blood interferon-gamma assay in patients with suspected pulmonary tuberculosis and AFB smear- and polymerase chain reaction-negative bronchial aspirates.

    Science.gov (United States)

    Lee, Jaehee; Lee, Shin Yup; Yoo, Seung Soo; Cha, Seung Ick; Won, Dong Il; Park, Jae Yong; Lee, Won-Kil; Kim, Chang Ho

    2012-07-01

    Combining a polymerase chain reaction (PCR) test with bronchoscopy is frequently performed to allow a rapid diagnosis of smear-negative pulmonary tuberculosis (PTB). However, limited data are available concerning clinical judgment in patients with suspected PTB and AFB smear- and PCR-negative bronchial aspirates (BA). The present study evaluated the usefulness of whole-blood QuantiFERON-TB Gold In-Tube (QFT) testing in these patients. Of 166 patients with suspected PTB who had undergone bronchoscopy because of smear-negative sputum or inadequate sputum production, 93 (56%) were diagnosed with culture-positive PTB. Seventy-four patients were either AFB smear- or PCR-positive. In the 75 patients whose BA AFB smear and PCR results were both negative, 19 were finally diagnosed with PTB by culture. The QFT test had a negative predictive value of 91% for PTB. The QFT test may be useful for excluding PTB in patients with suspected PTB whose BA AFB smear and PCR results are both negative. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Comparative analysis of {sup 99m}Tc-MDP three-phase bone scan with SPECT/CT and {sup 99m}Tc-HMPAO-labeled WBC SPECT/CT in the differential diagnosis of clinically suspicious post-traumatic osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Chan Woo; Lee, Soo Jin; Kim, Ji Young; Hwang, Kyu Tae; Choi, Yun Young [Hanyang University Medical CenterSeoul (Korea, Republic of)

    2017-03-15

    To identify differences between three-phase bone scan and SPECT/CT (TBS) and WBC SPECT/CT (WS) and compare diagnostic accuracies of each modality in patients with suspicious post-traumatic osteomyelitis (OM). Twenty-one patients with suspicious post-traumatic OM were enrolled. All patients performed TBS and WS within 1 week. Foci of MDP and WBC accumulation were divided into three categories: bone (OM), soft tissue (soft tissue inflammation; STI), negative for inflammation (NI). Confirmative diagnosis was made upon operative pathology or long-term clinical follow-up. Of 21 patients, four OM, eight STI, nine NI were finally diagnosed. TBS diagnosis was correct in three of four positive cases and nine of 17 negative cases. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV) of TBS were 75 %, 52.9 %, 57.1 %, 27.3 %, 90 %. WS diagnosis was correct in two of four positive cases and 17 of 17 negative cases. Sensitivity, specificity, accuracy, PPV, NPV were 50 %, 100 %, 81.0 %, 100 %, 89.5 %. Twelve of 21 cases showed agreement between TBS and WS. TBS misdiagnosed nine cases (six STI and two NI as eight OM; one OM as one STI), while WS misdiagnosed four cases (two OM as two STI; two STI as two NI). Combining results from TBS and WS led to better diagnostic accuracy (91.7 %) than either TBS or WS alone. TBS and WS showed moderate agreement in assessment of clinically suspected post-traumatic OM. WS better evaluated inflammation than TBS. WS tended to underestimate inflammation whereas TBS tended to overestimate inflammation. Combining TBS and WS enhanced diagnostic accuracy.

  19. Quantifying a Negative: How Homeland Security Adds Value

    Science.gov (United States)

    2015-12-01

    access to future victims. The Law Enforcement agency could then identifying and quantifying the value of future crimes. For example, if a serial ... killer is captured with evidence of the next victim or an established pattern of victimization, network theory could be used to identify the next

  20. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    International Nuclear Information System (INIS)

    Iannicelli, Elsa; Di Renzo, Sara; Ferri, Mario; Pilozzi, Emanuela; Di Girolamo, Marco; Sapori, Alessandra; Ziparo, Vincenzo; David, Vincenzo

    2014-01-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting

  1. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Iannicelli, Elsa; Di Renzo, Sara [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ferri, Mario [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Pilozzi, Emanuela [Department of Clinical and Molecular Sciences, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Di Girolamo, Marco; Sapori, Alessandra [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ziparo, Vincenzo [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); David, Vincenzo [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy)

    2014-07-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting.

  2. The performance characteristics of prostate-specific antigen and prostate-specific antigen density in Chinese men.

    Science.gov (United States)

    Teoh, Jeremy Yc; Yuen, Steffi Kk; Tsu, James Hl; Wong, Charles Kw; Ho, Brian Sh; Ng, Ada Tl; Ma, Wai-Kit; Ho, Kwan-Lun; Yiu, Ming-Kwong

    2017-01-01

    We investigated the performance characteristics of prostate-specific antigen (PSA) and PSA density (PSAD) in Chinese men. All Chinese men who underwent transrectal ultrasound-guided prostate biopsy (TRUS-PB) from year 2000 to 2013 were included. The receiver operating characteristic (ROC) curves for both PSA and PSAD were analyzed. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) at different cut-off levels were calculated. A total of 2606 Chinese men were included. For the ROC, the area under curve was 0.770 for PSA (P specificity of 14.1%, PPV of 29.5%, and NPV of 86.9%; PSAD of 0.12 ng ml-1 cc-1 had sensitivity of 94.5%, specificity of 26.6%, PPV of 32.8%, and NPV of 92.7%. On multivariate logistic regression analyses, PSA cut-off at 4.5 ng ml-1 (OR 1.61, 95% CI 1.05-2.45, P= 0.029) and PSAD cut-off at 0.12 ng ml-1 cc-1 (OR 6.22, 95% CI 4.20-9.22, Pprostate cancer detection on TRUS-PB. In conclusion, the performances of PSA and PSAD at different cut-off levels in Chinese men were very different from those in Caucasians. PSA of 4.5 ng ml-1 and PSAD of 0.12 ng ml-1 cc-1 had near 95% sensitivity and were significant predictors of prostate cancer detection in Chinese men.

  3. Efficacy of in-house fluorescent stain for fungus

    Directory of Open Access Journals (Sweden)

    K. R. L. Surya Kirani

    2017-01-01

    Full Text Available Context: Mycotic infections are gaining importance in the present day medicine, and definite demonstration of fungus is essential for diagnosis. Small numbers of organisms in the smear can be identified by fluorescence microscopy. Calcofluor white (CFW fluorescent stain is a textile brightener mixed with Evans blue. It is expensive and not easily available. Aims: (1 To assess the efficacy of in-house CFW fluorescent stain for fungus in relation to conventional CFW stain, histopathology, and culture. (2 To determine sensitivity, specificity, negative predictive value (NPV, and positive predictive value (PPV with culture as gold standard. Settings and Design: One hundred cases of suspected dermatophytosis and 15 cases of systemic mycosis were included in the study. Subjects and Methods: The local whitener Ranipal is added with Robin blue, another brightener, and was used to stain teased fungal cultures. Skin, hair, and nails require pretreatment with potassium hydroxide (KOH. Biopsy slides require deparaffinization and pretreatment with KOH before staining. Conventional calcofluor stain, histopathology, and culture were done. Statistical Analysis Used: Statistical analysis was performed using sensitivity, specificity, NPV, and PPV. Results: The results are consistently comparable with conventional stain. The sensitivity was 100%, specificity was 93.3%, NPV was 100%, and PPV was 85.7%. It is also cost effective when compared to commercial stains. Conclusions: In-house stain can be used for screening of fungus in direct samples, biopsies as alternative in resource-constrained laboratories.

  4. Evaluation of static and dynamic MRI for assessing response of bone sarcomas to preoperative chemotherapy: Correlation with histological necrosis

    International Nuclear Information System (INIS)

    Amit, Priyadarshi; Malhotra, Atul; Kumar, Rahul; Kumar, Lokesh; Patro, Dilip Kumar; Elangovan, Sundar

    2015-01-01

    Preoperative chemotherapy plays a key role in management of bone sarcomas. Postoperative evaluation of histological necrosis has been the gold standard method of assessing response to preoperative chemotherapy. This study was done to evaluate the efficacy of static and dynamic magnetic resonance imaging (MRI) for assessing response preoperatively. Our study included 14 patients (12 osteosarcomas and 2 malignant fibrous histiocytomas) with mean age of 21.8 years, treated with preoperative chemotherapy followed by surgery. They were evaluated with static and dynamic MRI twice, before starting chemotherapy and again prior to surgery. Change in tumor volume and slope of signal intensity - time curve were calculated and correlated with percentage of histological necrosis using Pearson correlation test. The change in dynamic MRI slope was significant (P = 0.001). Also, ≥60% reduction in slope of the curve proved to be an indicator of good histological response [positive predictive value (PPV) =80%]. Change in tumor volume failed to show significant correlation (P = 0.071). Although it showed high negative predictive value (NPV = 85.7%), PPV was too low (PPV = 57.14%). Dynamic MRI correctly predicts histological necrosis after administration of preoperative chemotherapy to bone sarcomas. Hence, it can be used as a preoperative indicator of response to neoadjuvant chemotherapy. On the other hand, volumetric assessment by static MRI is not an effective predictor of histological necrosis. This study proves the superiority of dynamic contrast-enhanced study over volumetric study by MRI

  5. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT.

    Science.gov (United States)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kaetsu, Yasuhiro; Kitao, Shinichiro; Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro; Ogawa, Toshihide

    2017-07-01

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. • Computed tomography angiography tends to overestimate stenosis in calcified coronary artery. • Dual-energy CT enables us to suppress calcification of coronary artery lesions. • Calcification-suppressed material density imaging reduces false-positive diagnosis of calcified lesion.

  6. The value of ultrasonographic measurement in carpal tunnel syndrome in patients with negative electrodiagnostic tests

    International Nuclear Information System (INIS)

    Koyuncuoglu, Hasan Rifat; Kutluhan, Suleyman; Yesildag, Ahmet; Oyar, Orhan; Guler, Kezban; Ozden, Ahmet

    2005-01-01

    The diagnosis of carpal tunnel syndrome (CTS) is mainly based on clinical findings and electrodiagnostic tests (EDT). However, EDT results do not support clinical findings in some cases. It has been recently suggested that ultrasonography (US) can be used to diagnose CTS. In this study, we aimed to investigate whether US has a diagnostic value for CTS in patients with negative EDT findings or not. EDT was performed on 319 wrists with clinical CTS findings in electrophysiology laboratory. Median and ulnar nerve conduction velocities were measured in all cases and electromyography was performed in patient with tenar atrophy and having suspicion involvement of brachial plexus as EDT. Fifty-nine wrists with negative EDT (study group) and 30 wrists from 15 healthy individuals (control group) were examined using US. The mean of cross-sectional areas (CSAs) measurements were found 8.83 ± 3.05 mm 2 by tracing method (TM) and 8.51 ± 3.13 mm 2 by ellipsoid formula (EF) in study group, and 7.63 ± 1.52 mm 2 by TM and 7.66 ± 1.42 mm 2 by EF in control group. The differences between study group and control group according to both TM and EF were significant (t-test p = 0.0079, p = 0.0460, respectively). In study group, CSAs were larger than 10.5 mm 2 in 18 (30.51%) and 16 (27.12%) wrists according to TM and EF findings, respectively, and in only one wrist (3.33%) in control group by both TM and EF. The differences of ultrasonographic CTS numbers between study group and control group were significant (p = 0.0024 by TM, p = 0.0086 by EF). We confirmed the usefulness of quantitative US assessment in the diagnosis of CTS in the patients with negative EDT findings. If EDT findings are inadequate to confirm the CTS in the patients with clinical CTS, US studies may be helpful to diagnose

  7. Role of apparent diffusion coefficient values and diffusion weighted magnetic resonance imaging in differentiation between benign and malignant thyroid nodules

    International Nuclear Information System (INIS)

    Incedayi, M.; Sivrioglu, A.; Mutlu, H.; Sonmez, G.; Velioglu, M.; Sildiroglu, O.; Basekim, C.; Kizilkaya, E.

    2012-01-01

    Full text: Objective: The purpose of the study was to differentiate between benign and malignant thyroid nodules using nodule-spinal cord signal intensity and nodule apparent diffusion coefficient (ADC) ratios on diffusion weighted magnetic resonance imaging. Materials and methods: Forty-four patients (27 females, 17 males; mean age 49) with nodules who underwent diffusion weighted magnetic resonance imaging (DW-MRI) were included in this study. The images were acquired with 0, 50, 400 and 1000 s/mm 2 b values. ADC maps were calculated afterwards. Fine needle aspiration biopsies (FNAB) were performed at the same day with DW-MRI acquisition. The diagnosis in patients where malignity was detected after FNAB was confirmed by histopathologic analysis of the operation material. The signal intensities of the spinal cord and the nodule were measured additionally, over b-1000 diffusion weighted images. Nodule /cord signal intensity (SI) ratios were obtained and the digital values were calculated by dividing to ADC values estimated for each nodule. Statistical analysis was performed. Results: The (nodule SI-cord SI)/nodule ADC ratio is calculated in the DW images and a statistically significant relationship was found between this ratio and the histopathology of the nodules (p<0.001). The ratio was determined as 0.27 in benign, and 0.86 in malignant lesions. The result of ROC analysis was statistically significant, and the area under Receiver Operating Characteristic (ROC) curve (100%) was considerably high. The threshold value was calculated as 0.56 according to the ROC analysis. According to this threshold value, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy rates for (nodule SI/cord SI)/ADC ratios in differentiating benign from malignant thyroid nodules are calculated as 100%, 97%, 83%, 100%, and 98%, respectively. Conclusion: We have found that (nodule/cord SI)/ nodule ADC ratio has the highest values for

  8. Termination of Resuscitation Rules to Predict Neurological Outcomes in Out-of-Hospital Cardiac Arrest for an Intermediate Life Support Prehospital System.

    Science.gov (United States)

    Cheong, Randy Wang Long; Li, Huihua; Doctor, Nausheen Edwin; Ng, Yih Yng; Goh, E Shaun; Leong, Benjamin Sieu-Hon; Gan, Han Nee; Foo, David; Tham, Lai Peng; Charles, Rabind; Ong, Marcus Eng Hock

    2016-01-01

    Futile resuscitation can lead to unnecessary transports for out-of-hospital cardiac arrest (OHCA). The Basic Life Support (BLS) and Advanced Life Support (ALS) termination of resuscitation (TOR) guidelines have been validated with good results in North America. This study aims to evaluate the performance of these two rules in predicting neurological outcomes of OHCA patients in Singapore, which has an intermediate life support Emergency Medical Services (EMS) system. A retrospective cohort study was carried out on Singapore OHCA data collected from April 2010 to May 2012 for the Pan-Asian Resuscitation Outcomes Study (PAROS). The outcomes of each rule were compared to the actual neurological outcomes of the patients. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and predicted transport rates of each test were evaluated. A total of 2,193 patients had cardiac arrest of presumed cardiac etiology. TOR was recommended for 1,411 patients with the BLS-TOR rule, with a specificity of 100% (91.9, 100.0) for predicting poor neurological outcomes, PPV 100% (99.7, 100.0), sensitivity 65.7% (63.6, 67.7), NPV 5.6% (4.1, 7.5), and transportation rate 35.6%. Using the ALS-TOR rule, TOR was recommended for 587 patients, specificity 100% (91.9, 100.0) for predicting poor neurological outcomes, PPV 100% (99.4, 100.0), sensitivity 27.3% (25.4, 29.3), NPV 2.7% (2.0, 3.7), and transportation rate 73.2%. BLS-TOR predicted survival (any neurological outcome) with specificity 93.4% (95% CI 85.3, 97.8) versus ALS-TOR 98.7% (95% CI 92.9, 99.8). Both the BLS and ALS-TOR rules had high specificities and PPV values in predicting neurological outcomes, the BLS-TOR rule had a lower predicted transport rate while the ALS-TOR rule was more accurate in predicting futility of resuscitation. Further research into unique local cultural issues would be useful to evaluate the feasibility of any system-wide implementation of TOR.

  9. Prognostic value of HPV E6/E7 mRNA assay in women with negative colposcopy or CIN1 histology result: a follow-up study.

    Directory of Open Access Journals (Sweden)

    Paolo Giorgi Rossi

    Full Text Available Pap test, and especially HPV DNA test, identify a large group of women who do not have any clinically relevant lesions, i.e., CIN2+ (Cervical Intraepithelial Neoplasia grade 2 or worse, but who are at greater risk of getting lesions in the future. The follow up of these women needs new biomarkers with prognostic value. The objective of this study is to evaluate the prognostic value of E6/E7 mRNA over-expression assay (PreTect HPV-Proofer, Norchip for 5 HR-HPV types (16, 18, 31, 33, and 45 for progression to CIN2+ after a negative colposcopy. This prospective study, conducted at four Italian centres, enrolled 673 women with either a negative colposcopy or a negative or CIN1 histology. The clinical end-point was histological confirmation of CIN2+. Women were classified at baseline according to mRNA results and managed according to local colposcopy protocols. At least one conclusive follow-up test was obtained for 347 women (25 months average lapse since recruitment, range 5-74. Only seven CIN2+ were detected during follow up, three among the 82 women positive for mRNA at baseline, two among the 250 negative (Fisher exact test, p = 0.02, and two among the 12 with an invalid test. Absolute CIN2+ risk was 6.7/1,000 person/years in the whole cohort. The absolute CIN2+ risk was 18.4/1,000 person/years and 3.6/1,000 person/years in mRNA-positive and mRNA-negative women, respectively. In conclusion, E6/E7 mRNA over-expression appears to be a good candidate as a prognostic biomarker to manage HR-HPV DNA-positive women with negative colposcopy or histology, particularly in order to decrease follow-up intensity in those who are negative.

  10. Positive predictive values by mammographic density and screening mode in the Norwegian Breast Cancer Screening Program.

    Science.gov (United States)

    Moshina, Nataliia; Ursin, Giske; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2016-01-01

    To investigate the probability of breast cancer among women recalled due to abnormal findings on the screening mammograms (PPV-1) and among women who underwent an invasive procedure (PPV-2) by mammographic density (MD), screening mode and age. We used information about 28,826 recall examinations from 26,951 subsequently screened women in the Norwegian Breast Cancer Screening Program, 1996-2010. The radiologists who performed the recall examinations subjectively classified MD on the mammograms into three categories: fatty (70%). Screening mode was defined as screen-film mammography (SFM) and full-field digital mammography (FFDM). We examined trends of PPVs by MD, screening mode and age. We used logistic regression to estimate odds ratio (OR) of screen-detected breast cancer associated with MD among women recalled, adjusting for screening mode and age. PPV-1 and PPV-2 decreased by increasing MD, regardless of screening mode (p for trend breasts. Among women recalled, the adjusted OR of breast cancer decreased with increasing MD. Compared with women with fatty breasts, the OR was 0.90 (95% CI: 0.84-0.96) for those with medium dense breasts and 0.85 (95% CI: 0.76-0.95) for those with dense breasts. PPVs decreased by increasing MD. Fewer women needed to be recalled or undergo an invasive procedure to detect one breast cancer among those with fatty versus dense breasts in the screening program in Norway, 1996-2010. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. The diagnostic value of 18F-FDG-PET/CT and MRI in suspected vertebral osteomyelitis - a prospective study.

    Science.gov (United States)

    Kouijzer, Ilse J E; Scheper, Henk; de Rooy, Jacky W J; Bloem, Johan L; Janssen, Marcel J R; van den Hoven, Leon; Hosman, Allard J F; Visser, Leo G; Oyen, Wim J G; Bleeker-Rovers, Chantal P; de Geus-Oei, Lioe-Fee

    2018-05-01

    The aim of this study was to determine the diagnostic value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT) and magnetic resonance imaging (MRI) in diagnosing vertebral osteomyelitis. From November 2015 until December 2016, 32 patients with suspected vertebral osteomyelitis were prospectively included. All patients underwent both 18 F-FDG-PET/CT and MRI within 48 h. All images were independently reevaluated by two radiologists and two nuclear medicine physicians who were blinded to each others' image interpretation. 18 F-FDG-PET/CT and MRI were compared to the clinical diagnosis according to international guidelines. For 18 F-FDG-PET/CT, sensitivity, specificity, PPV, and NPV in diagnosing vertebral osteomyelitis were 100%, 83.3%, 90.9%, and 100%, respectively. For MRI, sensitivity, specificity, PPV, and NPV were 100%, 91.7%, 95.2%, and 100%, respectively. MRI detected more epidural/spinal abscesses. An important advantage of 18 F-FDG-PET/CT is the detection of metastatic infection (16 patients, 50.0%). 18 F-FDG-PET/CT and MRI are both necessary techniques in diagnosing vertebral osteomyelitis. An important advantage of 18 F-FDG-PET/CT is the visualization of metastatic infection, especially in patients with bacteremia. MRI is more sensitive in detection of small epidural abscesses.

  12. Positive predictive value of a register-based algorithm using the Danish National Registries to identify suicidal events

    DEFF Research Database (Denmark)

    Gasse, Christiane; Danielsen, Andreas Aalkjaer; Pedersen, Marianne Giørtz

    2018-01-01

    events overall, by gender, age groups, and calendar time. RESULTS: We retrieved medical records for 357 (75%) people. The PPV of the DK-algorithm to identify suicidal events was 51.5% (95% CI: 46.4-56.7) overall, 42.7% (95% CI: 35.2-50.5) in males, and 58.5% (95% CI: 51.6-65.1) in females. The PPV varied...... further across age groups and calendar time. After excluding cases identified via the DK-algorithm by unspecific codes of intoxications and injury, the PPV improved slightly (56.8% [95% CI: 50.0-63.4]). CONCLUSIONS: The DK-algorithm can reliably identify self-harm with suicidal intention in 52......PURPOSE: It is not possible to fully assess intention of self-harm and suicidal events using information from administrative databases. We conducted a validation study of intention of suicide attempts/self-harm contacts identified by a commonly applied Danish register-based algorithm (DK...

  13. Acute subarachnoid haemorrhage: Is a negative CT angiogram enough?

    International Nuclear Information System (INIS)

    MacKinnon, A.D.; Clifton, A.G.; Rich, P.M.

    2013-01-01

    Aim: To determine the negative predictive value of 16 channel multisection computed tomography angiography (CTA) for detecting aneurysms in spontaneous subarachnoid haemorrhage (SAH), using digital subtraction angiography (DSA) as the reference standard. Materials and methods: The prospectively collected cerebral angiogram database of Department of Neuroradiology, Atkinson Morley Regional Neuroscience Centre was used to identify 200 consecutive patients who had undergone DSA for SAH. Of these, 176 had undergone CTA prior to DSA. Clinical details and radiology reports were correlated and images of positive investigations reviewed. Results: DSA showed one or more cerebral aneurysms in 105 (60%) patients. These were correctly reported on CTA in 100. CTA was reported negative for aneurysms in 74 patients. Of these five were false negative and had aneurysms detected on DSA. In the CTA/DSA negative group, 11 (16%) patients had classical perimesencephalic clinical syndrome and blood distribution. There were two false positives at CTA. For ruptured cerebral aneurysms, CTA had 95.2% sensitivity, 97.2% specificity, 98.1% positive predictive value, and 93.2% negative predictive value. Conclusion: The sensitivity and negative predictive value of CTA for ruptured aneurysms remains imperfect. Continued use of DSA is recommended in most patients with a negative CTA after acute SAH. Confirmation of a negative CTA result with DSA may not be routinely required in patients with perimesencephalic syndrome

  14. Positive predictive value of peptic ulcer diagnosis codes in the Danish National Patient Registry.

    Science.gov (United States)

    Viborg, Søren; Søgaard, Kirstine Kobberøe; Jepsen, Peter

    2017-01-01

    Diagnoses of peptic ulcer are registered in the Danish National Patient Registry (DNPR) for administrative as well as research purposes, but it is unknown whether the coding validity depends on the location of the ulcer. To validate the International Classification of Diseases, 10 th revision diagnosis codes of peptic ulcer in the DNPR by estimating positive predictive values (PPVs) for gastric and duodenal ulcer diagnoses. We identified all patients registered with a hospital discharge diagnosis of peptic ulcer from Aarhus University Hospital, Denmark, in 1995-2006. Among them, we randomly selected 200 who had an outpatient gastroscopy at the time of ulcer diagnosis. We reviewed the findings from these gastroscopies to confirm the presence of peptic ulcer and its location. We calculated PPVs and corresponding 95% confidence intervals (CIs) of gastric and duodenal ulcer diagnoses, using descriptions from the gastroscopic examinations as standard reference. In total, 182 records (91%) were available for review. The overall PPV of peptic ulcer diagnoses in DNPR was 95.6% (95% CI 91.5-98.1), with PPVs of 90.3% (95% CI 82.4-95.5) for gastric ulcer diagnoses, and 94.4% (95% CI 87.4-98.2) for duodenal ulcer diagnoses. PPVs were constant over time. The PPV of uncomplicated peptic ulcer diagnoses in the DNPR is high, and the location of the ulcers is registered correctly in most cases, indicating that the diagnoses are useful for research purposes.

  15. Deep Value

    DEFF Research Database (Denmark)

    Asness, Clifford S.; Liew, John M.; Pedersen, Lasse Heje

    premium. Following these episodes, the value strategy has (1) high average returns; (2) low market betas, but high betas to a global value factor; (3) deteriorating fundamentals; (4) negative news sentiment; (5) selling pressure; (6) increased limits to arbitrage; and (7) increased arbitrage activity...

  16. A novel fabrication of MEH-PPV/Al:ZnO nanorod arrays based ordered bulk heterojunction hybrid solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Malek, M.F., E-mail: firz_solarzelle@yahoo.com [NANO-ElecTronic Centre (NET), Faculty of Electrical Engineering, Universiti Teknologi MARA (UiTM), 40450 Shah Alam, Selangor (Malaysia); Sahdan, M.Z.; Mamat, M.H.; Musa, M.Z. [NANO-ElecTronic Centre (NET), Faculty of Electrical Engineering, Universiti Teknologi MARA (UiTM), 40450 Shah Alam, Selangor (Malaysia); Khusaimi, Z.; Husairi, S.S. [NANO-SciTech Centre (NST), Institute of Science (IOS), Universiti Teknologi MARA -UiTM, 40450 Shah Alam, Selangor (Malaysia); Md Sin, N.D. [NANO-ElecTronic Centre (NET), Faculty of Electrical Engineering, Universiti Teknologi MARA (UiTM), 40450 Shah Alam, Selangor (Malaysia); Rusop, M. [NANO-ElecTronic Centre (NET), Faculty of Electrical Engineering, Universiti Teknologi MARA (UiTM), 40450 Shah Alam, Selangor (Malaysia); NANO-SciTech Centre (NST), Institute of Science (IOS), Universiti Teknologi MARA - UiTM, 40450 Shah Alam, Selangor (Malaysia)

    2013-06-15

    Vertically aligned Al:ZnO nanorod arrays has been used as window layer in the fabrication of ordered bulk heterojuction hybrid solar cells. The utilization of the nanorod arrays will enhance the electron transport in vertical direction and also for light harvesting applications for high performance devices. The performance of this hybrid polymer/metal oxide photovoltaic devices based on MEH-PPV [poly(2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene)] and oriented Al:ZnO nanorod arrays is studied. The Al:ZnO nanorod arrays with a diameter of about 70–80 nm and thickness of approximately 500 nm were successfully grown on Al:ZnO-coated ITO substrate by sonicated sol–gel immersion technique. The photovoltaic performance of a short-circuit current density of 5.320 mA/cm{sup 2}, an open-circuit voltage of 195 mV and a fill factor of 27.71%, with a power conversion efficiency of about 0.287% under AM 1.5 illumination (100 mW/cm{sup 2}). To the best of our knowledge, preparation of aligned Al:ZnO nanorod arrays for this type of solar cell fabrication has not been reported by any research group.

  17. Aquaregia and Oxygen Plasma Treatments on Fluorinated Tin Oxide for Assembly of PLEDs Devices Using OC1C10-PPV as Emissive Polymer

    Directory of Open Access Journals (Sweden)

    Emerson Roberto SANTOS

    2009-02-01

    Full Text Available In this work were carried out treatments with oxygen plasma and aquaregia on fluorinated tin oxide (FTO films varying the treatment times. After treatments, the samples were analyzed by techniques measurements: sheet resistance, thickness, Hall effect, transmittance and superficial roughness. Devices using FTO/PEDOT:PSS/OC1C10-PPV/Al were assembled. In this experiment some variations were observed by sheet resistance and thickness and Hall effect measurements indicated most elevated carriers concentration and resistivity for aquaregia than that oxygen plasma. The roughness was elevated for the first minutes with treatment by aquaregia too. In the I-V curves the aquaregia devices presented the lowest threshold voltage for 30 minutes and devices treated by oxygen plasma presented a behavior most resistivity different of typical curves for PLEDs devices.

  18. Improvement in the luminous efficiency of MEH-PPV based light emitting diodes using zinc oxide nanorods grown by the electrochemical deposition technique on ITO substrates

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Rohini B; Kumar, Jitender; Madhwal, Devinder; Singh, Inderpreet; Nagpal, S; Bhatnagar, P K; Mathur, P C [Material Science Laboratory, Department of Electronic Science, University of Delhi South Campus, New Delhi (India); Kaur, I; Bhardwaj, L M, E-mail: email_rohini@rediffmail.com [Central Scientific Instruments Organization, Sector-30, Chandigarh (India)

    2011-07-01

    Zinc oxide (ZnO) nanorods grown by the electrochemical technique have been used to enhance the luminance of poly[2-methoxy-5-(2'-ethylhexoxy)-1,4-phenylenevinylene] (MEH-PPV)-based polymer light-emitting diodes. The luminance of the device with ZnO nanorods is found to increase by more than two times as compared with the device without ZnO nanorods. The diameter of the nanorods used in device fabrication was {approx}145 nm. The size of the nanorods was estimated from field emission scanning electron microscope images. Optical and structural characterizations of the nanorods were also performed by using absorption, photoluminescence and x-ray diffraction, confirming the formation of ZnO nanorods.

  19. Comparison of Swirl Sign and Black Hole Sign in Predicting Early Hematoma Growth in Patients with Spontaneous Intracerebral Hemorrhage.

    Science.gov (United States)

    Xiong, Xin; Li, Qi; Yang, Wen-Song; Wei, Xiao; Hu, Xi; Wang, Xing-Chen; Zhu, Dan; Li, Rui; Cao, Du; Xie, Peng

    2018-01-29

    BACKGROUND Early hematoma growth is associated with poor outcome in patients with spontaneous intracerebral hemorrhage (ICH). The swirl sign (SS) and the black hole sign (BHS) are imaging markers in ICH patients. The aim of this study was to compare the predictive value of these 2 signs for early hematoma growth. MATERIAL AND METHODS ICH patients were screened for the appearance of the 2 signs within 6 h after onset of symptoms. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the 2 signs in predicting early hematoma growth were assessed. The accuracy of the 2 signs in predicting early hematoma growth was analyzed by receiver-operator analysis. RESULTS A total of 200 patients were enrolled in this study. BHS was found in 30 (15%) patients, and SS was found in 70 (35%) patients. Of the 71 patients with early hematoma growth, BHS was found on initial computed tomography scans in 24 (33.8%) and SS in 33 (46.5%). The sensitivity, specificity, PPV, and NPV of BHS for predicting early hematoma growth were 33.8%, 95.3%, 80.0%, and 72.0%, respectively. The sensitivity, specificity, PPV, and NPV of SS were 46.5%, 71.3%, 47.0%, and 71.0%, respectively. The area under the curve was 0.646 for BHS and 0.589 for SS (P=0.08). Multivariate logistic regression showed that presence of BHS is an independent predictor of early hematoma growth. CONCLUSIONS The Black hole sign seems to be good predictor for hematoma growth. The presence of swirl sign on admission CT does not independently predict hematoma growth in patients with ICH.

  20. Role of serum S100B and PET-CT in follow-up of patients with cutaneous melanoma

    Directory of Open Access Journals (Sweden)

    Novakovic Srdjan

    2011-08-01

    Full Text Available Abstract Background Increased level of serum S100B can serve as a marker of metastatic spread in patients with cutaneous melanoma (CM. In patients with elevated S100 B and/or clinical signs of disease progression PET-CT scan is a valuable tool for discovering metastases and planning treatment. The aims of this study were to determine whether regular measurements of serum S100B are a useful tool for discovering patients with CM metastases and to evaluate the diagnostic value of PET-CT during the follow-up. Methods From September 2007 to February 2010, 115 CM patients included in regular follow up at the Institute of Oncology Ljubljana were appointed to PET-CT. There were 82 (71.3% patients with clinical signs of disease progression and 33 (28.7% asymptomatic patients with two subsequent elevated values of S100B. Sensitivity, specificity, positive and negative predictive value (PPV, NPV of S100B and PET-CT were calculated using standard procedures. Results Disease progression was confirmed in 81.7% of patients (in 86.5% of patients with clinical signs of disease progression and in 69.7% of asymptomatic patients with elevated S100B. Sensitivity, specificity, PPV and NPV of S100B was 33.8%, 90.9%, 96.0% and 17.5% in patients with clinical signs of disease progression. In 20.0% of patients increased serum S100B was the only sign of disease progression. Sensitivity and PPV of S100 in this group of patients were 100.0% and 69.7%. With PET-CT disease progression was diagnosed in 84.2% of symptomatic patients and in 72.7% of asymptomatic patients with elevated S100B. The sensitivity, specificity, PPV and NPV of PET-CT for symptomatic patients was 98.5%, 90.9%, 98.5% and 90.9% and 100%, 90.0%, 95.8% and 100% for asymptomatic patients with elevated S100. Conclusions Measurements of serum S100B during regular follow-up of patients with CM are a useful tool for discovering disease progression in asymptomatic patients. The value of its use increases if

  1. Additional value of integrated PET/CT over PET alone in the initial staging and follow up of head and neck malignancy

    International Nuclear Information System (INIS)

    Ishikita, Tomohiro; Oriuchi, Noboru; Higuchi, Tetsuya

    2010-01-01

    Clinical application of fluorodeoxyglucose (FDG)-positron emission tomography (PET) in head and neck cancer includes identification of metastases, unknown primary head and neck malignancy, or second primary carcinoma, and also recurrent tumor after treatment. In this study, the additional value of PET/CT fusion images over PET images alone was evaluated in patients with initial staging and follow up of head and neck malignancy. Forty patients with suspected primary head and neck malignancy and 129 patients with suspected relapse after treatment of head and neck malignancy were included. FDG-PET/CT study was performed after the intravenous administration of FDG (5 MBq/kg). Target of evaluation was set at primary tumor, cervical lymph node, and whole body. PET images and PET with CT fusion images were compared. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Results of PET and PET/CT were compared with postoperative histopathological examination, and case by case comparison of PET and PET/CT results for each region was performed. The additional value of CT images over PET only images was assessed. Statistical differences in sensitivity and specificity were evaluated. In the comparative evaluation of 507 targets by PET alone and PET/CT, 401 targets showed agreement of the results. Of the 106 discordant targets, 103 showed a positive result on PET alone and negative result on PET/CT. These results showed a significant difference (p<0.01). Sensitivity of PET/CT was slightly higher than that of PET without statistical significance, while specificity of PET/CT was significantly higher than that of PET alone (Initial Staging: 90.5% vs. 62.2%, p<0.01; Follow up: 97.2% vs. 74.4%, p<0.01). In Fisher's direct probability test, a significant difference was noted in the sensitivity (Initial staging: 91.3% vs. 87.0%, p<0.01; Follow up: 93.9% vs. 91.4%, p<0.01). Combined PET/CT showed improved diagnostic

  2. Characterization of sour cherry isolates of plum pox virus from the Volga Basin in Russia reveals a new cherry strain of the virus.

    Science.gov (United States)

    Glasa, Miroslav; Prikhodko, Yuri; Predajňa, Lukáš; Nagyová, Alžbeta; Shneyder, Yuri; Zhivaeva, Tatiana; Subr, Zdeno; Cambra, Mariano; Candresse, Thierry

    2013-09-01

    Plum pox virus (PPV) is the causal agent of sharka, the most detrimental virus disease of stone fruit trees worldwide. PPV isolates have been assigned into seven distinct strains, of which PPV-C regroups the genetically distinct isolates detected in several European countries on cherry hosts. Here, three complete and several partial genomic sequences of PPV isolates from sour cherry trees in the Volga River basin of Russia have been determined. The comparison of complete genome sequences has shown that the nucleotide identity values with other PPV isolates reached only 77.5 to 83.5%. Phylogenetic analyses clearly assigned the RU-17sc, RU-18sc, and RU-30sc isolates from cherry to a distinct cluster, most closely related to PPV-C and, to a lesser extent, PPV-W. Based on their natural infection of sour cherry trees and genomic characterization, the PPV isolates reported here represent a new strain of PPV, for which the name PPV-CR (Cherry Russia) is proposed. The unique amino acids conserved among PPV-CR and PPV-C cherry-infecting isolates (75 in total) are mostly distributed within the central part of P1, NIa, and the N terminus of the coat protein (CP), making them potential candidates for genetic determinants of the ability to infect cherry species or of adaptation to these hosts. The variability observed within 14 PPV-CR isolates analyzed in this study (0 to 2.6% nucleotide divergence in partial CP sequences) and the identification of these isolates in different localities and cultivation conditions suggest the efficient establishment and competitiveness of the PPV-CR in the environment. A specific primer pair has been developed, allowing the specific reverse-transcription polymerase chain reaction detection of PPV-CR isolates.

  3. Comparative effectiveness of 50g glucose challenge test and risk ...

    African Journals Online (AJOL)

    ... of 50g glucose challenge test and risk factor based screening in detection of ... Mean maternal and gestational ages at recruitment were 30.8+1.2 years and ... Predictive Value, PPV - 20%) compared to risk factors only (PPV- 11.1%).

  4. Pediatric FAST and elevated liver transaminases: An effective screening tool in blunt abdominal trauma.

    Science.gov (United States)

    Sola, Juan E; Cheung, Michael C; Yang, Relin; Koslow, Starr; Lanuti, Emma; Seaver, Chris; Neville, Holly L; Schulman, Carl I

    2009-11-01

    The current standard for the evaluation of children with blunt abdominal trauma (BAT) consists of physical examination, screening lab values, and computed tomography (CT) scan. We sought to determine if the focused assessment with sonography for trauma (FAST) combined with elevated liver transaminases (AST/ALT) could be used as a screening tool for intra-abdominal injury (IAI) in pediatric patients with BAT. Registry data at a level 1 trauma center was retrospectively reviewed from 1991-2007. Data collected on BAT patients under the age of 16 y included demographics, injury mechanism, ISS, GCS, imaging studies, serum ALT and AST levels, and disposition. AST and ALT were considered positive if either one was >100 IU/L. Overall, 3171 cases were identified. A total of 1008 (31.8%) patients received CT scan, 1148 (36.2%) had FAST, and 497 (15.7%) patients received both. Of the 497 patients, 400 (87.1%) also had AST and ALT measured. FAST was 50% sensitive, 91% specific, with a positive predictive value (PPV) of 68%, negative predictive value (NPV) of 83%, and accuracy of 80%. Combining FAST with elevated AST or ALT resulted in a statistically significant increase in all measures (sensitivity 88%, specificity 98%, PPV 94%, NPV 96%, accuracy 96%). FAST combined with AST or ALT > 100 IU/L is an effective screening tool for IAI in children following BAT. Pediatric patients with a negative FAST and liver transaminases < 100 IU/L should be observed rather than subjected to the radiation risk of CT.

  5. Validation of the cephalosporin intradermal skin test for predicting immediate hypersensitivity: a prospective study with drug challenge.

    Science.gov (United States)

    Yoon, S-Y; Park, S Y; Kim, S; Lee, T; Lee, Y S; Kwon, H-S; Cho, Y S; Moon, H-B; Kim, T-B

    2013-07-01

    Cephalosporin is a major offending agent in terms of drug hypersensitivity along with penicillin. Cephalosporin intradermal skin tests (IDTs) have been widely used; however, their validity for predicting immediate hypersensitivity has not been studied. This study aimed to determine the predictive value of cephalosporin intradermal skin testing before administration of the drug. We prospectively conducted IDTs with four cephalosporins, one each of selected first-, second-, third-, or fourth-generation cephalosporins: ceftezol; cefotetan or cefamandole; ceftriaxone or cefotaxime; and flomoxef, respectively, as well as with penicillin G. After the skin test, whatever the result, one of the tested cephalosporins was administered intravenously and the patient was carefully observed. We recruited 1421 patients who required preoperative cephalosporins. Seventy-four patients (74/1421, 5.2%) were positive to at least one cephalosporin. However, none of responders had immediate hypersensitivity reactions after a challenge dose of the same or different cephalosporin, which were positive in the skin test. Four patients who suffered generalized urticaria and itching after challenge gave negative skin tests for the corresponding drug. The IDT for cephalosporin had a sensitivity of 0%, a specificity of 97.5%, a negative predictive value of 99.7%, and a positive predictive value (PPV) of 0%, when challenged with the same drugs that were positive in the skin test. Routine skin testing with a cephalosporin before its administration is not useful for predicting immediate hypersensitivity because of the extremely low sensitivity and PPV of the skin test (CRIS registration no. KCT0000455). © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Validation of intensive care unit-acquired infection surveillance in the Italian SPIN-UTI network.

    Science.gov (United States)

    Masia, M D; Barchitta, M; Liperi, G; Cantù, A P; Alliata, E; Auxilia, F; Torregrossa, V; Mura, I; Agodi, A

    2010-10-01

    Validity is one of the most critical factors concerning surveillance of nosocomial infections (NIs). This article describes the first validation study of the Italian Nosocomial Infections Surveillance in Intensive Care Units (ICUs) project (SPIN-UTI) surveillance data. The objective was to validate infection data and thus to determine the sensitivity, specificity, and positive and negative predictive values of NI data reported on patients in the ICUs participating in the SPIN-UTI network. A validation study was performed at the end of the surveillance period. All medical records including all clinical and laboratory data were reviewed retrospectively by the trained physicians of the validation team and a positive predictive value (PPV), a negative predictive value (NPV), sensitivity and specificity were calculated. Eight ICUs (16.3%) were randomly chosen from all 49 SPIN-UTI ICUs for the validation study. In total, the validation team reviewed 832 patient charts (27.3% of the SPIN-UTI patients). The PPV was 83.5% and the NPV was 97.3%. The overall sensitivity was 82.3% and overall specificity was 97.2%. Over- and under-reporting of NIs were related to misinterpretation of the case definitions and deviations from the protocol despite previous training and instructions. The results of this study are useful to identify methodological problems within a surveillance system and have been used to plan retraining for surveillance personnel and to design and implement the second phase of the SPIN-UTI project. Copyright 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Serum prostate-specific antigen as surrogate for the Histological ...

    African Journals Online (AJOL)

    A serum PSA of ≥ 30 ng/ml had a positive predictive value (PPV) of 90% at a specificity of 87% and sensitivity of 78%, while a PSA ≥ 60 ng/ ml had a PPV of 98% at a specificity of 98% and sensitivity of 65% for the presence of prostate cancer. The PPV reached 99% at a PSA ≥ 100 ng/ ml and 100% at a PSA ≥ 500 ng/ ml ...

  8. Validation of an Arab names algorithm in the determination of Arab ancestry for use in health research

    Science.gov (United States)

    El-Sayed, Abdulrahman M.; Lauderdale, Diane S.; Galea, Sandro

    2010-01-01

    Objective Data about Arab-Americans, a growing ethnic minority, is not routinely collected in vital statistics, registry, or administrative data in the US. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically-based, probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. Design We used data from all Michigan birth certificates between 2000-2005. Fathers’ surnames and mothers’ maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Results State-wide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and a NPV of 98.6%. Both the false positive and false negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false positive rate increased and false-negative rate decreased. Conclusion The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA. PMID:20845117

  9. Sinusoidal obstructive syndrome diagnosed with superparamagnetic iron oxide-enhanced magnetic resonance imaging in patients with chemotherapy-treated colorectal liver metastases.

    Science.gov (United States)

    Ward, Janice; Guthrie, James A; Sheridan, Maria B; Boyes, Sheila; Smith, Jonathan T; Wilson, Daniel; Wyatt, Judy I; Treanor, Darren; Robinson, Philip J

    2008-09-10

    To assess the predictive value of superparamagnetic iron oxide (SPIO) -enhanced T2-weighted gradient echo (GRE) imaging to determine the presence and severity of sinusoidal obstructive syndrome (SOS). Sixty hepatic resection patients with colorectal metastases treated with chemotherapy underwent unenhanced magnetic resonance imaging (MRI) followed by T2-weighted GRE sequences obtained after SPIO. The images were reviewed in consensus by two experienced observers who determined the presence and severity of linear and reticular hyperintensities, indicating SOS-type liver injury, using a 4-point ordinal scale. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% CIs for the detection of SOS were calculated. Twenty-four of 60 patients had moderate to severe SOS on MRI. MRI achieved a sensitivity of 87% (95% CI, 66% to 97%), specificity of 89% (95% CI, 75% to 97%), PPV of 83% (95% CI, 63% to 95%), and NPV of 92% (95% CI, 77% to 98%). SOS was never found at surgery or histology in patients whose background liver parenchyma was normal on SPIO-enhanced MRI. SOS is present in a significant proportion of patients with treated colorectal metastases and is effectively detected on SPIO-enhanced T2-weighted GRE images.

  10. Solitary Pulmonary Nodule on Helical Dynamic CT Scans: Analysis of the Enhancement Patterns Using a Computer-Aided Diagnosis (CAD) System

    International Nuclear Information System (INIS)

    Choi, Eun Jung; Jin, Gong Yong; Han, Young Min; Lee, Young Sun; Kweon, Keun Sang

    2008-01-01

    We wanted to investigate the usefulness of a computer-aided diagnosis (CAD) system in assisting radiologists to diagnosis malignant solitary pulmonary nodules (SPNs), as compared with diagnosing SPNs with using direct personal drawing. Forty patients with SPNs were analyzed. After the pre-contrast scan was performed, an additional ten series of post-contrast images were obtained at 20-second intervals. Two investigators measured the attenuation values of the SPNs: a radiologist who drew the regions of interest (ROIs), and a technician who used a CAD system. The Bland and Altman plots were used to compare the net enhancement between a CAD system and direct personal drawing. The diagnostic characteristics of the malignant SPNs were calculated by considering the CAD and direct personal drawing and with using Fisher's exact test. On the Bland and Altman plot, the net enhancement difference between the CAD system and direct personal drawing was not significant (within ± 2 standard deriation). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosing malignant SPNs using CAD was 92%, 85%, 75%, 96% and 88%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of diagnosing malignant SPNs using direct drawing was 92%, 89%, 79%, 92% and 88%, respectively. The CAD system was a useful tool for diagnosing malignant SPNs

  11. Four cases of endophthalmitis after 25-gauge pars plana vitrectomy

    Directory of Open Access Journals (Sweden)

    Mutoh T

    2012-08-01

    Full Text Available Tetsuya Mutoh, Koji Kadoya, Makoto ChikudaDepartment of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya, Saitama, JapanAbstract: We report our recent experience with four cases of endophthalmitis (one male, three females after 25-gauge pars plana vitrectomy (PPV. One was a case of persistent cystoid macular edema caused by branch retinal vein occlusion, whereas the remaining three were cases of epiretinal membrane. Preoperative antibiotics before the first PPV procedure were not administered in three of the four cases. Endophthalmitis occurred 2–4 days after the first procedure in all cases, for which ceftazidime 2.0 mg/0.1 mL and vancomycin 1.0 mg/0.1 mL were injected into the vitreous cavity. This was followed by emergent 20-gauge PPV and intraocular lens removal using an infusion fluid containing ceftazidime and vancomycin. After the second PPV procedure, progress was good in three cases while retinal detachment occurred in the remaining case one month after surgery; this case required a third PPV procedure. Final best-corrected visual acuity ranged from 20/100 to 20/25 for the four cases. Bacterial cultures were negative after the second PPV procedure in all cases. In conclusion, postoperative endophthalmitis occurred in four of 502 cases (0.80% that underwent 25-gauge PPV at our hospital. It is important to minimize the incidence of endophthalmitis after 25-gauge PPV.Keywords: 25-gauge pars plana vitrectomy, endophthalmitis, incidence

  12. Molecular characterization of Plum pox virus Rec isolates from Russia suggests a new insight into evolution of the strain.

    Science.gov (United States)

    Chirkov, Sergei; Ivanov, Peter; Sheveleva, Anna; Kudryavtseva, Anna; Mitrofanova, Irina

    2018-04-01

    Field isolates of Plum pox virus (PPV), belonging to the strain Rec, have been found for the first time in Russia. Full-size genomes of the isolates K28 and Kisl-1pl from myrobalan and plum, respectively, were sequenced on the 454 platform. Analysis of all known PPV-Rec complete genomes using the Recombination Detection Program (RDP4) revealed yet another recombination event in the 5'-terminal region. This event was detected by seven algorithms, implemented in the RDP4, with statistically significant P values and supported by a phylogenetic analysis with the bootstrap value of 87%. A putative PPV-M-derived segment, encompassing the C-terminus of the P1 gene and approximately two-thirds of the HcPro gene, is bordered by breakpoints at positions 760-940 and 1838-1964, depending on the recombinant isolate. The predicted 5'-distal breakpoint for the isolate Valjevka is located at position 2804. The Dideron (strain D) and SK68 (strain M) isolates were inferred as major and minor parents, respectively. Finding of another recombination event suggests more complex evolutionary history of PPV-Rec than previously assumed. Perhaps the first recombination event led to the formation of a PPV-D variant harboring the PPV-M-derived fragment within the 5'-proximal part of the genome. Subsequent recombination of its descendant with PPV-M in the 3'-proximal genomic region resulted in the emergence of the evolutionary successful strain Rec.

  13. Screening for Binge Eating Disorders Using the Patient Health Questionnaire in a Community Sample

    Science.gov (United States)

    Striegel-Moore, Ruth H.; Perrin, Nancy; DeBar, Lynn; Wilson, G. Terence; Rosselli, Francine; Kraemer, Helena C.

    2009-01-01

    Objective To examine the operating characteristics of the Patient Health Questionnaire eating disorder module (PHQ-ED) for identifying bulimia nervosa/binge eating disorder (BN/BED) or recurrent binge eating (RBE) in a community sample, and to compare true positive (TP) versus false positive (FP) cases on clinical validators. Method 259 screen positive individuals and a random sample of 89 screen negative cases completed a diagnostic interview. Sensitivity, specificity, and Positive Predictive Value (PPV) were calculated. TP and FP cases were compared using t-tests and Chi-Square tests. Results The PHQ-ED had high sensitivity (100%) and specificity (92%) for detecting BN/BED or RBE, but PPV was low (15% or 19%). TP and FP cases did not differ significantly on frequency of subjective bulimic episodes, objective overeating, restraint, on BMI, and on self-rated health. Conclusions The PHQ-ED is recommended for use in large populations only in conjunction with follow-up questions to rule out cases without objective bulimic episodes. PMID:19424976

  14. Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.

    Science.gov (United States)

    Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia

    2009-01-01

    Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.

  15. The diagnostic accuracy of physical examination compared to lung ultrasound for determining lung congestion in hemodialysis patients who have reached their dry weight

    Science.gov (United States)

    Rahardjo, K. D.; Dharmaeizar; Nainggolan, G.; Harimurti, K.

    2017-08-01

    Research has shown that hemodialysis patients with lung congestion have high morbidity and mortality. Patients were assumed to be free of lung congestion if they had reached their post-dialysis dry weight. Most often, to determine if the patient was free of lung congestion, physical examination was used. However, the accuracy of physical examination in detecting lung congestion has not been established. To compare the capabilities of physical examination and lung ultrasound in detection of lung congestion, cross-sectional data collection was conducted on hemodialysis patients. Analysis was done to obtain proportion, sensitivity, specificity, positive predictive value, negative predictive value, and positive likelihood ratio. Sixty patients participated in this study. The inter observer variation of 20 patients revealed a kappa value of 0.828. When all 60 patients were taken into account, we found that 36 patients (57.1%) had lung congestion. Mild lung congestion was found in 24 (38.1%), and 12 (19%) had a moderate degree of congestion. In the analysis comparing jugular venous pressure to lung ultrasound, we found that sensitivity was 0.47 (0.31-0.63), specificity was 0.73 (0.54-0.86), positive predictive value (PPV) was 0.51 (0.36-0.67), negative predictive value (NPV) was 0.70 (0.49-0.84), positive likelihood ratio (PLR) was 1.75 (0.88-3.47), and the negative likelihood ratio (NLR) was 0.72 (0.47-1.12). In terms of lung auscultation, we found that sensitivity was 0.56 (0.39-0.71), specificity was 0.54 (0.35-0.71), PPV was 0.61 (0.44-0.76), NPV was 0.48 (0.31-0.66), PLR was 1.21 (0.73-2.0), and NLR was 0.82 (0.49-1.38). The results of our study showed that jugular venous distention and lung auscultation examination are not reliable means of detecting lung congestion.

  16. Analysis of participant factors that affect the diagnostic performance of screening mammography: A report of the alliance for breast cancer screening in Korea

    International Nuclear Information System (INIS)

    Kim, Young Joong; Lee, Eu Hye

    2017-01-01

    To analyze participant factors that affect the diagnostic performance of screening mammography. We enrolled 128756 cases from 10 hospitals between 2005 and 2010. We analyzed recall rate, cancer detection rate (CDR) per 1000 examinations, positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), and interval cancer rate (ICR) per 1000 negative examinations according to participant factors including age, breast density, and number of visit to the same institution, and adjusted for confounding variables. Increasing age improved recall rates (27.4% in 40's, 17.5% in 50's, 11.1% in 60's, and 8.6% in 70's), CDR (2.7, 3.2, 2.0, and 2.4), PPV (1.0, 1.8, 1.8, and 2.8%), sensitivity (81.3, 88.8, 90.3, and 94.7%), specificity (72.7, 82.7, 89.0, and 91.7%), and FPR (27.3, 17.3, 11.0, and 8.4%) (p < 0.05). Higher breast density impaired recall rates (4.0% in P1, 9.0% in P2, 28.9% in P3, and 27.8% in P4), PPV (3.3, 2.3, 1.2, and 1.3%), specificity (96.1, 91.2, 71.4, and 72.5%), and FPR (3.9, 8.9, 28.6, and 27.6%) (p < 0.001). It also increased CDR (1.3, 2.1, 3.3, and 3.6) and ICR (0.2, 0.3, 0.6, and 1.6) (p < 0.05). Successive visits to the same institution improved recall rates (20.9% for one visit, 10.7% for two visits, 7.7% for more than three visits), PPV (1.6, 2.8, and 2.7%), specificity (79.4, 89.6, and 92.5%), and FPR (20.6, 10.4, and 7.5%) (p < 0.001). Young age and dense breasts negatively affected diagnostic performance in mammography screening, whereas successive visits to the same institution had a positive effect. Examinee education for successive visits to the same institution would improve the diagnostic performance

  17. Analysis of participant factors that affect the diagnostic performance of screening mammography: A report of the alliance for breast cancer screening in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Joong [Dept. of Radiology, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of); Lee, Eu Hye [Dept. of Radiology, Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); and others

    2017-08-01

    To analyze participant factors that affect the diagnostic performance of screening mammography. We enrolled 128756 cases from 10 hospitals between 2005 and 2010. We analyzed recall rate, cancer detection rate (CDR) per 1000 examinations, positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), and interval cancer rate (ICR) per 1000 negative examinations according to participant factors including age, breast density, and number of visit to the same institution, and adjusted for confounding variables. Increasing age improved recall rates (27.4% in 40's, 17.5% in 50's, 11.1% in 60's, and 8.6% in 70's), CDR (2.7, 3.2, 2.0, and 2.4), PPV (1.0, 1.8, 1.8, and 2.8%), sensitivity (81.3, 88.8, 90.3, and 94.7%), specificity (72.7, 82.7, 89.0, and 91.7%), and FPR (27.3, 17.3, 11.0, and 8.4%) (p < 0.05). Higher breast density impaired recall rates (4.0% in P1, 9.0% in P2, 28.9% in P3, and 27.8% in P4), PPV (3.3, 2.3, 1.2, and 1.3%), specificity (96.1, 91.2, 71.4, and 72.5%), and FPR (3.9, 8.9, 28.6, and 27.6%) (p < 0.001). It also increased CDR (1.3, 2.1, 3.3, and 3.6) and ICR (0.2, 0.3, 0.6, and 1.6) (p < 0.05). Successive visits to the same institution improved recall rates (20.9% for one visit, 10.7% for two visits, 7.7% for more than three visits), PPV (1.6, 2.8, and 2.7%), specificity (79.4, 89.6, and 92.5%), and FPR (20.6, 10.4, and 7.5%) (p < 0.001). Young age and dense breasts negatively affected diagnostic performance in mammography screening, whereas successive visits to the same institution had a positive effect. Examinee education for successive visits to the same institution would improve the diagnostic performance.

  18. Negative-mass lagging cores of the big bang

    International Nuclear Information System (INIS)

    Miller, B.D.

    1976-01-01

    Examples are given of spherically symmetric cosmological models containing space-sections with the following properties: at large values of the geometrically defined coordinate R, the mass is positive, while at small values of R, the mass is negative. The negative-mass region of spacetime has local properties similar to those of the negative-mass Schwarzschild solution. The big bang in these models is partially spacelike and partially timelike, so the spacetimes do not obey the strong form of the cosmic censorship hypothesis. The timelike, negative-mass segments of the big bang are unlimited sources of electromagnetic and gravitational radiation, and as such may be attractive as ''lagging core'' models of highly energetic astrophysical phenomena

  19. Negative-mass lagging cores of the big bang

    Energy Technology Data Exchange (ETDEWEB)

    Miller, B.D.

    1976-09-01

    Examples are given of spherically symmetric cosmological models containing space-sections with the following properties: at large values of the geometrically defined coordinate R, the mass is positive, while at small values of R, the mass is negative. The negative-mass region of spacetime has local properties similar to those of the negative-mass Schwarzschild solution. The big bang in these models is partially spacelike and partially timelike, so the spacetimes do not obey the strong form of the cosmic censorship hypothesis. The timelike, negative-mass segments of the big bang are unlimited sources of electromagnetic and gravitational radiation, and as such may be attractive as ''lagging core'' models of highly energetic astrophysical phenomena. (AIP)

  20. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    Directory of Open Access Journals (Sweden)

    Linda C. Rogers

    2016-01-01

    Full Text Available Objective Accurate and timely diagnosis of rupture of membranes (ROM is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus® in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy. Results Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%, specificity (94.8% vs. 79.3%, PPV (75% vs. 36.8%, NPV (100% vs. 95.8%, and accuracy (95.5% vs. 79.1%. Conclusions The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

  1. Comparison of four urease-dependent tests of detecting HP infection

    International Nuclear Information System (INIS)

    Han Yuan; Huang Gang; Zhu Cuiying; Ling Liqun

    2001-01-01

    Objective: The aim of this study is to compare the four urease-dependent tests of detecting Hp infection. The authors used following method: 1) rapid urease test (RUT), 2) 14 C urea breath test ( 14 C-UBT), 3) 13 C urea breath test which is measured by with infrared spectrometry ( 13 C-UBT1), 4) 13 C urea breath test with mass spectrometry ( 13 C-UBT). Methods: 54 patients underwent RUT, 14 C-UBT, 13 C-UBT1, 13 C-UBT2 respectively. Results: Sensitivity and specificity, accurate rate, positive predictive value (PPV), negative predictive value (NPV), respectively, were as follows: RUT (82.1%, 80%, 81.5%, 91.4%, 63.2%), 14 C-UBT (97.4%, 100%, 98.1%, 100%, 93.8%), 13 C-UBT1 (100%, 93.3%, 98.1%, 97.5%, 100%), 13 C-UBT2 (100%, 86.7%, 96.3%, 95.1%, 100%), PPV of four tests are not significantly different (P>0.05). Conclusion: Four urease-dependent tests are high sensitive and accurate methods for detecting Hp infection. UBT is an ideal tool for diagnosis, screen and follow-up of Hp infection

  2. Comparison between arthroscopy and 3 dimensional double echo steady state 3D-DESS sequences in magnetic resonance imaging of internal derangements of the knee

    International Nuclear Information System (INIS)

    Dongola, Nagwa A.; Gishen, Philip

    2004-01-01

    This study was performed with the aim of evaluating the usefulness of 3 dimensional double-echo steady state sequences in examining the internal derangements of the knee. Arthroscopy was used as a referral standard. The study was performed in the Radiology and Arthroscopy Departments of Kings College Hospital, London, United Kingdom, during a 6-month period from January 1997 to June 1997. All patients who had knee magnetic resonance imaging within 3 months of arthroscopy were retrospectively studied. Thirty-three patients fulfilled these criteria and were selected. Three dimensional double-echo steady state sequences produced sensitivity for detecting meniscal tears of 87.5% for medial menisci (MM) and 75% for lateral menisci (LM). Specificity was 76% for MM and 96% for LM; positive predictive value (PPV) was 46.1% for MM and 85.7% for LM and negative predictive value (NPV) of 95% for MM and 96% for LM. The sensitivity for the anterior cruciate ligament was 83.3%, specificity was 77.7%, PPV was 45.4% and NPV was 95.4%. Three dimensional double-echo steady state sequences are useful in evaluating internal derangement of the knee, especially in advanced cartilage lesions. (author)

  3. Turning negative into positive: public health mass media campaigns and negative advertising.

    Science.gov (United States)

    Apollonio, D E; Malone, R E

    2009-06-01

    Literature suggests that 'negative advertising' is an effective way to encourage behavioral changes, but it has enjoyed limited use in public health media campaigns. However, as public health increasingly focuses on non-communicable disease prevention, negative advertising could be more widely applied. This analysis considers an illustrative case from tobacco control. Relying on internal tobacco industry documents, surveys and experimental data and drawing from political advocacy literature, we describe tobacco industry and public health research on the American Legacy Foundation's "truth" campaign, an example of effective negative advertising in the service of public health. The tobacco industry determined that the most effective advertisements run by Legacy's "truth" campaign were negative advertisements. Although the tobacco industry's own research suggested that these negative ads identified and effectively reframed the cigarette as a harmful consumer product rather than focusing solely on tobacco companies, Philip Morris accused Legacy of 'vilifying' it. Public health researchers have demonstrated the effectiveness of the "truth" campaign in reducing smoking initiation. Research on political advocacy demonstrating the value of negative advertising has rarely been used in the development of public health media campaigns, but negative advertising can effectively communicate certain public health messages and serve to counter corporate disease promotion.

  4. Determining the negative effect on house values of proximity to a landfill site by means of an application of the hedonic pricing method

    Directory of Open Access Journals (Sweden)

    Mario Du Preez

    2011-08-01

    Full Text Available This study applied the hedonic pricing method to determine whether a disused, solid waste landfill site has an adverse effect on the prices of low-cost houses in New Brighton, a neighbourhood of the Nelson Mandela Metropole, Eastern Cape, South Africa. The results of the study show that the landfill site has a negative effect on New Brighton house prices. The average increase in house value is R36.00 per one hundred metres from the landfill site. This increase amounts to 0.44 percent of the value of a house per 100 metres from the landfill. When the change in value is summed for all the properties in the sample area (allowing for variation in value change due to differing distances from the landfill site the total disamenity effect of the landfill site is approximately R1.4 million.

  5. School Leadership in Turbulent Times and the Value of Negative Capability

    Science.gov (United States)

    Clarke, Simon

    2016-01-01

    Given the turbulence of the contemporary education environment this paper argues it is necessary to adopt more flexible approaches to leadership than has traditionally been the case and involving new ways of learning and behaviours. In this regard, the paper investigates the paradoxical concept of "negative capability" and its potential…

  6. Measurements of diagnostic examination performance using quantitative apparent diffusion coefficient and proton MR spectroscopic imaging in the preoperative evaluation of tumor grade in cerebral gliomas

    International Nuclear Information System (INIS)

    Server, Andres; Kulle, Bettina; Gadmar, Oystein B.; Josefsen, Roger; Kumar, Theresa; Nakstad, Per H.

    2011-01-01

    Purpose: Tumor grading is very important both in treatment decision and evaluation of prognosis. While tissue samples are obtained as part of most therapeutic approaches, factors that may result in inaccurate grading due to sampling error (namely, heterogeneity in tissue sampling, as well as tumor-grade heterogeneity within the same tumor specimen), have led to a desire to use imaging better to ascertain tumor grade. The purpose in our study was to evaluate the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the curve (AUC), and accuracy of diffusion-weighted MR imaging (DWI), proton MR spectroscopic imaging (MRSI) or both in grading primary cerebral gliomas. Materials and methods: We performed conventional MR imaging (MR), DWI, and MRSI in 74 patients with newly diagnosed brain gliomas: 59 patients had histologically verified high-grade gliomas: 37 glioblastomas multiform (GBM) and 22 anaplastic astrocytomas (AA), and 15 patients had low-grade gliomas. Apparent diffusion coefficient (ADC) values of tumor and peritumoral edema, and ADC ratios (ADC in tumor or peritumoral edema to ADC of contralateral white matter, as well as ADC in tumor to ADC in peritumoral edema) were determined from three regions of interest. The average of the mean, maximum, and minimum for ADC variables was calculated for each patient. The metabolite ratios of Cho/Cr and Cho/NAA at intermediate TE were assessed from spectral maps in the solid portion of tumor, peritumoral edema and contralateral normal-appearing white matter. Tumor grade determined with the two methods was then compared with that from histopathologic grading. Logistic regression and receiver operating characteristic (ROC) curve analysis were performed to determine optimum thresholds for tumor grading. Measures of diagnostic examination performance, such as sensitivity, specificity, PPV, NPV, AUC, and accuracy for identifying high-grade gliomas were also calculated

  7. Intra-prosthetic breast MR virtual navigation: a preliminary study for a new evaluation of silicone breast implants.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Capuano, Giulia; Rella, Leonarda; Scardapane, Arnaldo; Angelelli, Giuseppe; Stabile Ianora, Amato Antonio

    2013-10-01

    To assess the contribute of intra-prosthetic MRI virtual navigation for evaluating breast implants and detecting implant ruptures. Forty-five breast implants were evaluated by MR examination. Only patients with a clinical indication were assessed. A 1.5-T device equipped with a 4-channel breast coil was used by performing axial TSE-T2, axial silicone-only, axial silicone suppression and sagittal STIR images. The obtained dicom files were also analyzed by using virtual navigation software. Two blinded radiologists evaluated all MR and virtual images. Eight patients for a total of 13 implants underwent surgical replacement. Sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated for both imaging strategies. Intra-capsular rupture was diagnosed in 13 out of 45 (29%) implants by using MRI. Basing on virtual navigation, 9 (20%) cases of intra-capsular rupture were diagnosed. Sensitivity, specificity, accuracy, PPV and NPV values of 100%, 86%, 89%, 62% and 100%, respectively, were found for MRI. Virtual navigation increased the previous values up to 100%, 97%, 98%, 89% and 100%. Intra-prosthetic breast MR virtual navigation can represent an additional promising tool for the evaluation of breast implants being able to reduce false positives and to provide a more accurate detection of intra-capsular implant rupture signs. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Hemizona Assay and Sperm Penetration Assay in the Prediction of IVF Outcome: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Paraskevi Vogiatzi

    2013-01-01

    Full Text Available The limited predictive value of semen analysis in achieving natural conception or in IVF outcome confirms the need for sperm function tests to determine optimal management. We reviewed HZA and SPA predictive power in IVF outcome, with statistical significance of diagnostic power of the assays. HZA was readily efficient in predicting IVF outcome, while evident inconsistency among the studies analysed framed the SPA’s role in male fertility evaluation. Considerable variation was noted in the diagnostic accuracy values of SPA with wide sensitivity (52–100%, specificity (0–100%, and PPV (18–100% and NPV (0–100% together with fluctuation and notable differentiation in methodology and cutoff values employed by each group. HZA methodology was overall consistent with minor variation in cutoff values and oocyte source, while data analysis reported strong correlation between HZA results with IVF outcome, high sensitivity (75–100%, good specificity (57–100%, and high PPV (79–100% and NPV (68–100%. HZA correlated well with IVF outcome and demonstrated better sensitivity/specificity and positive/negative predictive power. Males with normal or slightly abnormal semen profiles could benefit by this intervention and could be evaluated prior to referral to assisted reproduction. HZA should be used in a sequential fashion with semen analysis and potentially other bioassays in an IVF setting.

  9. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Tadros, Anthony S.; Huang, Brady K. [University of California, Department of Radiology, San Diego, CA (United States); Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan [Scripps Clinic, Department of Orthopedic Surgery, La Jolla, CA (United States); Chang, Eric Y. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California, Department of Radiology, San Diego, CA (United States)

    2015-09-15

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  10. Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yang; Ma, Yue; Wang, Yuke; Yu, Mei; Guo, Qiyong [Shengjing Hospital of China Medical University, Department of Radiology, Shenyang (China); Fan, Weipeng [Central Hospital of Anshan, Department of Radiology, Anshan (China); Vembar, Mani [CT Clinical Science Philips Healthcare, Cleveland, OH (United States)

    2014-01-15

    To evaluate the accuracy of low-dose coronary CTA with iterative reconstruction (IR) in the diagnosis of coronary artery disease (CAD) in patients with suspected CAD. Ninety-six patients with suspected CAD underwent low-dose prospective electrocardiogram-gated coronary CTA, with images reconstructed using IR. Image quality (IQ) of coronary segments were graded on a 4-point scale (4, excellent; 1, non-diagnostic). With invasive coronary angiography (ICA) considered the ''gold standard'', the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of coronary CTA were calculated on segment-, vessel- and patient-based levels. The patient data were divided into two groups (Agatston scores of ≥ 400 and <400). The differences in diagnostic performance between the two groups were tested. Diagnostic image quality was found in 98.1 % (1,232/1,256) of segments. The sensitivity, specificity, PPV, NPV and accuracy were 90.8 %, 95.3 %, 81.8 %, 97.8 % and 94.3 % (segment-based) and 97.2 %, 83.3 %, 94.6 %, 90.9 % and 93.8 % (patient-based). Significant differences between the two groups were seen in specificity, PPV and accuracy (92.1 % vs. 97.9 %, 76.0 % vs. 86.7 %, 91.7 % vs. 96.6 %, P < 0.05; segment-based). The average effective dose was 1.30 ± 0.15 mSv. Low-dose prospective coronary CTA with IR can acquire satisfactory image quality and show high diagnostic accuracy in patients with suspected CAD; however, blooming continues to pose a challenge in severely calcified segments. (orig.)

  11. Are screening instruments valid for psychotic-like experiences? A validation study of screening questions for psychotic-like experiences using in-depth clinical interview.

    LENUS (Irish Health Repository)

    Kelleher, Ian

    2012-02-01

    Individuals who report psychotic-like experiences are at increased risk of future clinical psychotic disorder. They constitute a unique "high-risk" group for studying the developmental trajectory to schizophrenia and related illnesses. Previous research has used screening instruments to identify this high-risk group, but the validity of these instruments has not yet been established. We administered a screening questionnaire with 7 items designed to assess psychotic-like experiences to 334 adolescents aged 11-13 years. Detailed clinical interviews were subsequently carried out with a sample of these adolescents. We calculated sensitivity and specificity and positive predictive value (PPV) and negative predictive value (NPV) for each screening question for the specific symptom it enquired about and also in relation to any psychotic-like experience. The predictive power varied substantially between items, with the question on auditory hallucinations ("Have you ever heard voices or sounds that no one else can hear?") providing the best predictive power. For interview-verified auditory hallucinations specifically, this question had a PPV of 71.4% and an NPV of 90.4%. When assessed for its predictive power for any psychotic-like experience (including, but not limited to, auditory hallucinations), it provided a PPV of 100% and an NPV of 88.4%. Two further questions-relating to visual hallucinations and paranoid thoughts-also demonstrated good predictive power for psychotic-like experiences. Our results suggest that it may be possible to screen the general adolescent population for psychotic-like experiences with a high degree of accuracy using a short self-report questionnaire.

  12. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    International Nuclear Information System (INIS)

    Tadros, Anthony S.; Huang, Brady K.; Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan; Chang, Eric Y.

    2015-01-01

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  13. Ditection of coronary artery disease: accuracy of 64- slice computed tomography versus converntional invasive angiography

    Directory of Open Access Journals (Sweden)

    Taghizadeh M

    2008-11-01

    Full Text Available "nBackground: Multislice computed tomography (MSCT is a noninvasive method of detecting coronary artery disease (CAD. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT in daily practice, without patient selection. "nMethods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA. The CT system The mean time span between MSCT and QCA was 7.2±3.9 days. For the 64-MSCT, detection or exclusion of CAD, defined as one or more areas of >50% stenosis within major epicardial coronary arteries, the sensitivity, specificity, diagnostic accuracy, positive predictive value (PPV, and negative predictive value (NPV were evaluated both per patient and per segment. "nResults: Sixty-one of the 64 coronary CT angiograms (95% were of diagnostic image quality. QCA showed significant CAD in 64% (39/61 of the patients, with the other 36% (22/61 showing nonsignificant disease or no disease. Sensitivity, specificity, accuracy, PPV, and NPV of 64-MSCT per patient were 92%, 86%, 90%, 92% and 96%, respectively. By the per-segment analysis, 695 of 791 coronary artery segments were assessable (88%. Of these, 64-MSCT showed a sensitivity of 80%, specificity of 92%, accuracy of 90%, PPV of 65%, and NPV of 96%, respectively, in detecting CAD. "nConclusions: Both per patient and per segment analyses for coronary 64-MSCT showed a higher diagnostic accuracy than QCA. This suggests 64-MSCT should primarily be used for risk stratification on a per patient basis as a noninvasive gate-keeper diagnostic method.

  14. Are screening instruments valid for psychotic-like experiences? A validation study of screening questions for psychotic-like experiences using in-depth clinical interview.

    LENUS (Irish Health Repository)

    Kelleher, Ian

    2011-03-01

    Individuals who report psychotic-like experiences are at increased risk of future clinical psychotic disorder. They constitute a unique "high-risk" group for studying the developmental trajectory to schizophrenia and related illnesses. Previous research has used screening instruments to identify this high-risk group, but the validity of these instruments has not yet been established. We administered a screening questionnaire with 7 items designed to assess psychotic-like experiences to 334 adolescents aged 11-13 years. Detailed clinical interviews were subsequently carried out with a sample of these adolescents. We calculated sensitivity and specificity and positive predictive value (PPV) and negative predictive value (NPV) for each screening question for the specific symptom it enquired about and also in relation to any psychotic-like experience. The predictive power varied substantially between items, with the question on auditory hallucinations ("Have you ever heard voices or sounds that no one else can hear?") providing the best predictive power. For interview-verified auditory hallucinations specifically, this question had a PPV of 71.4% and an NPV of 90.4%. When assessed for its predictive power for any psychotic-like experience (including, but not limited to, auditory hallucinations), it provided a PPV of 100% and an NPV of 88.4%. Two further questions-relating to visual hallucinations and paranoid thoughts-also demonstrated good predictive power for psychotic-like experiences. Our results suggest that it may be possible to screen the general adolescent population for psychotic-like experiences with a high degree of accuracy using a short self-report questionnaire.

  15. Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification

    International Nuclear Information System (INIS)

    Lin, C.-J.; Hsu, J.-C.; Lai, Y.-J.; Wang, K.-L.; Lee, J.-Y.; Li, A.-H.; Chu, S.-H.

    2010-01-01

    Aim: To assess the ability of coronary angiography performed using dual-source computed tomography (DSCT) to evaluate coronary artery disease (CAD) in a population with unselected heart rates and extensive coronary calcification. Materials and methods: Forty-four patients at intermediate to high risk for CAD underwent both DSCT coronary angiography and invasive coronary angiography (ICA) within 30 days. No beta blockers were administered prior to imaging. Image quality and quantitatively stenosis of all coronary segments with a diameter ≥1.5 mm were accessed. Patients were stratified according to mean heart rate (<70 versus ≥70 bpm) and heart rate variability (<10 versus ≥10 bpm). DSCT detection of coronary stenosis by segment, vessel, and patient characteristics were compared to the reference standard of ICA. Results: Diagnostic accuracy for all patients was high regarding sensitivity (97%), positive predictive value (PPV, 84.2%), and negative predictive value (NPV, 83.3%) but low regarding specificity (45.5%) with a moderate interobserver agreement (Kappa = 0.50). The accuracy for vessel-based diagnosis was high regarding sensitivity (96.6%), specificity (80.8%), PPV (80.3%), and NPV (96.7%). The segment-based diagnostic results revealed a moderate interobserver agreement for image quality and sensitivity, specificity, PPV and NPV for all segments of 66.9, 97.8, 90.8, and 89.9%, respectively. Conclusion: DSCT coronary angiography has high diagnostic accuracy in assessing CAD among patients at intermediate to high risk without using heart rate-modulating premedication. DSCT is not superior to ICA for diagnosis of calcified segments.

  16. Validation of an algorithm-based definition of treatment resistance in patients with schizophrenia.

    Science.gov (United States)

    Ajnakina, Olesya; Horsdal, Henriette Thisted; Lally, John; MacCabe, James H; Murray, Robin M; Gasse, Christiane; Wimberley, Theresa

    2018-02-19

    Large-scale pharmacoepidemiological research on treatment resistance relies on accurate identification of people with treatment-resistant schizophrenia (TRS) based on data that are retrievable from administrative registers. This is usually approached by operationalising clinical treatment guidelines by using prescription and hospital admission information. We examined the accuracy of an algorithm-based definition of TRS based on clozapine prescription and/or meeting algorithm-based eligibility criteria for clozapine against a gold standard definition using case notes. We additionally validated a definition entirely based on clozapine prescription. 139 schizophrenia patients aged 18-65years were followed for a mean of 5years after first presentation to psychiatric services in South-London, UK. The diagnostic accuracy of the algorithm-based measure against the gold standard was measured with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). A total of 45 (32.4%) schizophrenia patients met the criteria for the gold standard definition of TRS; applying the algorithm-based definition to the same cohort led to 44 (31.7%) patients fulfilling criteria for TRS with sensitivity, specificity, PPV and NPV of 62.2%, 83.0%, 63.6% and 82.1%, respectively. The definition based on lifetime clozapine prescription had sensitivity, specificity, PPV and NPV of 40.0%, 94.7%, 78.3% and 76.7%, respectively. Although a perfect definition of TRS cannot be derived from available prescription and hospital registers, these results indicate that researchers can confidently use registries to identify individuals with TRS for research and clinical practices. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Utility of intraoperative frozen sections in surgical decision making for acute invasive fungal rhinosinusitis.

    Science.gov (United States)

    Papagiannopoulos, Peter; Lin, Diana Murro; Al-Khudari, Samer; Rajan, Kumar; Reddy, Swathi; Gattuso, Paulo; Tajudeen, Bobby; Batra, Pete S

    2017-05-01

    Acute invasive fungal rhinosinusitis (AIFRS) represents a fulminant, potentially fatal, disease process in immunocompromised patients. The diagnosis often rests on high index of clinical suspicion, with relative paucity of data on the diagnostic and therapeutic implications of intraoperative frozen sections. Retrospective review was performed for 18 cases undergoing endoscopic sinus surgery for AIFRS. Reliability of intraoperative frozen section diagnosis was evaluated for all patients using final pathology as the gold standard. A total of 66 frozen sections were performed. Diagnostic accuracy of frozen sections illustrated sensitivity of 72.7% (95% confidence interval [CI], 0.57 to 0.85), specificity of 100% (95% CI, 0.85 to 1.00), positive predictive value (PPV) of 100% (95% CI, 0.89 to 1.00), and negative predictive value (NPV) of 64.7% (95% CI, 0.46 to 0.80). There was no statistically significant difference in sensitivity of frozen sections in cases of Mucor and Aspergillus at 68.8%% and 76.2%, respectively (p = 0.61). This study represents the largest series assessing the diagnostic accuracy of frozen section analysis in AIFRS. Frozen section analysis is an effective tool for guiding intraoperative decision making in patients with AIFRS with a high PPV. A Low NPV underscores the importance of clinical suspicion and intraoperative decision making based on endoscopic findings when negative frozen section results are encountered. Further, frozen section analysis appears to be equally effective in detecting either Mucor or Aspergillus. © 2017 ARS-AAOA, LLC.

  18. Latex agglutination using the periplasmic proteins antigen of Brucella melitensis is a successful, rapid, and specific serodiagnostic test for ovine brucellosis.

    Science.gov (United States)

    Ismael, Alaa Bassuny; Swelum, Ayman Abdel-Aziz; Mostafa, Salama A-H; Alhumiany, Abdel-Rahman A

    2016-09-01

    Brucellosis, especially caused by Brucella melitensis, is considered the most-widespread zoonosis in the world, particularly in developing countries. This study was planned to develop an accurate test for diagnosis of ovine brucellosis using a specific hot saline extracted soluble Brucella melitensis periplasmic proteins (SBPPs). The efficacy of the latex agglutination test (LAT) using SBPPs compared to the Rose Bengal test (RBT), buffered plate agglutination test (BPAT), serum agglutination test (SAT), and an indirect enzyme-linked immunosorbent assay (i-ELISA) was evaluated in the field diagnosis of ovine brucellosis. The test performance was evaluated by estimating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), disease prevalence (DP), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) using test agreement and bacteriological culture in 1777 samples. The false-positive result was significantly (P ⩽0.05) lower in LAT than RBT, BPAT, SAT, and i-ELISA. With reference to test agreement, the Se, Sp, PPV, and PLR were highest (P ⩽0.05) in LAT 99.33%, 99.88%, 98.68%, and 827.25%, respectively. With reference to bacteriological culture, the LAT and i-ELISA tests showed a significant difference in Se with SAT. However, no significant difference in specificity was detected. The DP was 8.44% in the five tests. In conclusion, LAT using SBPPs of B. melitensis could be a suitable serodiagnostic field test for ovine brucellosis, with high sensitivity and specificity. © The Author(s) 2016.

  19. Minimal invasive biopsy results of 'uncertain malignant potential' in digital mammography screening. High prevalence but also high predictive value for malignancy

    International Nuclear Information System (INIS)

    Weigel, S.; Heindel, W.; Universitaetsklinikum Muenster; Decker, T.; Universitaetsklinikum Muenster; Korsching, E.; Biesheuvel, C.; Woestmann, A.; Boecker, W.; Hungermann, D.; Roterberg, K.; Tio, J.

    2011-01-01

    Purpose: To evaluate the rate, the histological spectrum and the positive predictive value (PPV) for malignancy of minimally invasive biopsies with 'uncertain malignant potential (B3)' in digital mammography screening. Methods and Materials: Consecutive data of 37 178 participants of one digital unit of the German screening program were included. Results: The B 3 rate was 15.1 % (148/979). The frequencies of lesion subtypes were as follows: atypical epithelial proliferation of ductal type (AEPDT) 35.1 % (52/148), radial scar (RS) 28.4 % (42/148), papillary lesions (PAP) 20.3 % (30/148), lobular carcinoma in situ 8.8 % (13/148), flat epithelial atypia 5.4 % (8/148), and mucocele-like lesions 2.0 % (3/148). The PPV for malignancy in surgical excisions was overall 0.28 (25/91); in detail 0.40 (19/47) for AEPDT, 0.20 (5/25) for RS, 0.08 (1/12) for PAP. Conclusion: Despite a higher B 3 rate of minimally invasive biopsies with 'uncertain malignant potential' in digital screening, the benign surgical biopsy rate is not disproportionally increased compared with analog screening programs. Together with defined management protocols, this results in an increased cancer detection rate per screening participant with surgical excision. (orig.)

  20. Art, Terrorism and the Negative Sublime

    Directory of Open Access Journals (Sweden)

    Arnold Berleant

    2009-01-01

    Full Text Available The range of the aesthetic has expanded to cover not only a wider range of objects and situations of daily life but also to encompass the negative. This includes terrorism, whose aesthetic impact is central to its use as a political tactic. The complex of positive and negative aesthetic values in terrorism are explored, introducing the concept of the sublime as a negative category to illuminate the analysis and the distinctive aesthetic of terrorism.

  1. Hyperfunctioning parathyroid tumours in patients with thyroid nodules. Sensitivity and positive predictive value of high-resolution ultrasonography and 99mTc-sestamibi scintigraphy.

    Science.gov (United States)

    Lumachi, F; Marzola, M C; Zucchetta, P; Tregnaghi, A; Cecchin, D; Bui, F

    2003-09-01

    A series of 112 consecutive patients with primary hyperparathyroidism who underwent both high-resolution neck ultrasonography (US) and 99mTc-sestamibi/99mTc-pertechnetate subtraction scintigraphy (SS) prior to successful parathyroidectomy was reviewed. There were 29 (25.9%) men and 83 (74.1%) women, with a median age of 58 years (range 13-78 years). Patients were divided into two groups, according to the preoperative US findings: group A (87 patients, 77.7%) without thyroid diseases, and group B (25 patients, 22.3%) with either multinodular goitre or a solitary nontoxic thyroid nodule. In group B patients partial or total thyroidectomy was also performed, according to the intraoperative findings and frozen-section examination results. Final histopathology showed 99 (88.4%) solitary parathyroid (PT) adenomas and 3 (2.7%) PT carcinomas, while 10 (8.9%) patients had a multiglandular disease. The sensitivity and positive predictive value (PPV) were (group A vs group B) 79.8% vs 70.8% (P=0.25) and 95.7% vs 94.4% (P=0.58) for US, and 83.3% vs 87.0% (P=0.47) and 95.9% vs 90.9% (P=0.32) for SS respectively. Better but similar (P=not significant) results were obtained in patients with solitary PT tumours: 81.5% vs 77.8% (US) and 85.0 vs 94.1% (SS) sensitivity; 97.1% vs 93.3% (US) and 95.8% vs 88.9% (SS) PPV. Overall, the combination of US and SS was 92.9% sensitive (group A=93.1%, group B=92.0%; P=0.55), and the PPV reached 100% in each group. In conclusion, in patients with primary hyperparathyroidism the results of both US and SS are independent of coexistent thyroid disease, especially in patients with solitary PT tumours.

  2. Interpretation of the French negation ne…pas

    DEFF Research Database (Denmark)

    Nølke, Henning

    2017-01-01

    .), I distinguish three interpretation types of sentence negation, and I propose a polyphonic analysis according to which the polemic use is fundamental. e metalinguistic and descriptive negations are derived from this primary value. I show that this pragmatic semantic analysis has some precise...

  3. Value of contrast-enhanced sonographic micro flow imaging for prostate cancer detection with t-PSA level of 4–10 ng/mL

    International Nuclear Information System (INIS)

    Guo, Yi-Fen; Li, Feng-Hua; Xie, Shao-Wei; Xia, Jian-Guo; Fang, Hua; Li, Hong-Li

    2012-01-01

    Objectives: To compare the efficiency of contrast-enhanced ultrasonographic micro flow imaging (MFI) with conventional transrectal ultrasound (TRUS) in detecting prostate cancer with serum total prostate-specific antigen (t-PSA) of 4.0–10.0 ng/mL. To evaluate the value of contrast-enhanced ultrasonographic MFI in detecting prostate cancer with t-PSA in diagnostic gray zone. Methods: 47 patients with t-PSA 4.0–10.0 ng/mL underwent gray scale, power Doppler TRUS and MFI examinations before ultrasound guided biopsies. Biopsies were performed at twelve sites in the base, the mid-gland and the apex of the prostate in each patient, when there was no abnormal ultrasound finding. When an abnormality was present at MFI, the biopsy specimen from the corresponding site was directed toward the abnormal finding. With histological results of prostate biopsy as reference standards, we assessed the cancer detection of these three methods. Results: 564 specimens were collected in this study, in which 101 were prostate cancer confirmed histologically. 152 of 564 specimens were demonstrated abnormal on MFI images, in which 71 were malignant and 81 were benign confirmed histologically. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) for MFI in detecting prostate caner were 70.3%, 82.5%, 80.3%, 46.7% and 92.7%, respectively. The sensitivity and NPV for MFI were significantly better than gray scale (38.6%, 86.9%) and power Doppler (32.7%, 86.0%) (P < 0.001) TRUS. Conclusions: Contrast-enhanced ultrasonographic MFI could significantly improve the detection rate of prostate cancer with t-PSA in diagnostic gray zone (4–10 ng/mL) than conventional ultrasound.

  4. Direct MR Arthrography of the wrist in comparison with Arthroscopy: A prospective study on 125 patients; Direkte MR-Arthrographie des Handgelenks im Vergleich zur Arthroskopie: Eine prospektive Studie an 125 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R.; Christopoulos, G.; Coblenz, G.; Froehner, S. [Institut fuer Diagnostische und Interventionelle Radiologie der Herz- und Gefaessklinik GmbH, Bad Neustadt an der Saale (Germany); Meier, R.; Lanz, U.; Krimmer, H. [Klinik fuer Handchirurgie GmbH, Bad Neustadt an der Saale (Germany)

    2003-07-01

    Objective: In literature the diagnostic value of MRI for detecting lesions of the carpal ligaments and the TFCC is judged controversially. The aim of the following study is to determine the diagnostic accuracy of direct MR arthrography for depicting and staging of intraarticular lesions of the wrist. Material and methods: One day before undergoing arthroscopy, 125 patients suffering from wrist pain were examined with direct MR arthrography in a prospective and blinded study. A mixture of contrast medium (iodine-containing contrast medium and gadopentetate in relation 200:1) was injected into both radiocarpal and midcarpal joints. The following sequences were acquired on a 1.5T scanner: coronal T1-weighted SE, coronal fat-saturated T1-weighted SE, coronal T1-/T2*-DESS-3D, and sagittal T2*-weighted MEDIC. MRI results were compared with arthroscopic findings using statistical analysis (SEN=sensitivity, SPE=specificity, PPV=positive predictive value, NPV=negative predictive value, ACC=accuracy). Results: In comparison to arthroscopy as the accepted diagnostic gold standard, the following results were found for MR arthrography. Detection of TFCC lesions: SEN 97.1%, SPE 96.4%, PPV 97.1%, NPV 96.4%, ACC 96.8%. Detection of complete tears of the scapholunate ligament: SEN 91.7%, SPE 100%, PPV 100%, NPV 99.1%, ACC 99.2%. Detection of partial tears: SEN 62.5%, SPE 100%, PPV 100%, NPV 94.8%, ACC 95.2%. Detection of cartilage defects: SEN 84.2%, SPE 96.2%, PPV 80%, NPV 97.1%, ACC 94.4%. In total, only three lesions of the lunotriquetral ligament were present. Conclusion: Direct MR arthrographic imaging is well suited for detecting intraarticular lesions of the wrist. The presented diagnostic results of MR arthrography are superior to the results of unenhanced MRI reported in the literature. Direct MR arthrography as a reliable diagnostic tool is strongly recommended if lesions of the scapholunate ligament and the triangular fibrocartilage complex are suspected. In contrast, an

  5. The diagnostic performance of CT-derived fractional flow reserve for evaluation of myocardial ischaemia confirmed by invasive fractional flow reserve: a meta-analysis.

    Science.gov (United States)

    Li, S; Tang, X; Peng, L; Luo, Y; Dong, R; Liu, J

    2015-05-01

    To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFRCT, with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for FFRCT were 89% (85-93%), 71% (65-75%), 70% (65-75%), 90% (85-93%), 3.31 (1.79-6.14), 0.16 (0.11-0.23), and 21.21 (9.15-49.15) at the patient-level, and 83% (78-63%), 78% (75-81%), 61% (56-65%), 92% (89-90%), 4.02 (1.84-8.80), 0.22 (0.13-0.35), and 19.15 (5.73-63.93) at the vessel-level. At per-patient analysis, FFRCT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR-, and DOR versus those of CTA. At per-vessel analysis, FFRCT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR-, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFRCT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. FFRCT, which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Assessment of the performances of AcuStar HIT and the combination with heparin-induced multiple electrode aggregometry: a retrospective study.

    Science.gov (United States)

    Minet, V; Bailly, N; Douxfils, J; Osselaer, J C; Laloy, J; Chatelain, C; Elalamy, I; Chatelain, B; Dogné, J M; Mullier, F

    2013-09-01

    Early diagnosis of immune heparin-induced thrombocytopenia (HIT) is challenging. HemosIL® AcuStar HIT and heparin-induced multiple electrode aggregometry (HIMEA) were recently proposed as rapid diagnostic methods. We conducted a study to assess performances of AcuStar HIT-IgG (PF4-H) and AcuStar HIT-Ab (PF4-H). The secondary objective was to compare the performances of the combination of Acustar HIT and HIMEA with standardised clinical diagnosis. Sera of 104 suspected HIT patients were retrospectively tested with AcuStar HIT. HIMEA was performed on available sera (n=81). The clinical diagnosis was established by analysing in a standardized manner the patient's medical records. These tests were also compared with PF4-Enhanced®, LTA, and SRA in subsets of patients. Thresholds were determined using ROC curve analysis with clinical outcome as reference. Using the recommended thresholds (1.00AU), the negative predictive value (NPV) of HIT-IgG and HIT-Ab were 100.0% (95% CI: 95.9%-100.0% and 95.7%-100.0%). The positive predictive value (PPV) were 64.3% (95% CI: 35.1%-87.2.2%) and 45.0% (95% CI: 23.2%-68.6%), respectively. Using our thresholds (HIT-IgG: 2.89AU, HIT-Ab: 9.41AU), NPV of HIT-IgG and HIT-Ab were 100.0% (95% CI: 96.0%-100.0% and 96.1%-100.0%). PPV were 75.0% (95% CI: 42.7%-94.5%) and 81.8% (95% CI: 48.3%-97.7%), respectively. Of the 79 patients with a medium-high pretest probability score, 67 were negative using HIT-IgG (PF4-H) test at our thresholds. HIMEA was performed on HIT-IgG positive patients. Using this combination, only one patient on 79 was incorrectly diagnosed. Acustar HIT showed good performances to exclude the diagnosis of HIT. Combination with HIMEA improves PPV. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Isotropic Negative Thermal Expansion Metamaterials.

    Science.gov (United States)

    Wu, Lingling; Li, Bo; Zhou, Ji

    2016-07-13

    Negative thermal expansion materials are important and desirable in science and engineering applications. However, natural materials with isotropic negative thermal expansion are rare and usually unsatisfied in performance. Here, we propose a novel method to achieve two- and three-dimensional negative thermal expansion metamaterials via antichiral structures. The two-dimensional metamaterial is constructed with unit cells that combine bimaterial strips and antichiral structures, while the three-dimensional metamaterial is fabricated by a multimaterial 3D printing process. Both experimental and simulation results display isotropic negative thermal expansion property of the samples. The effective coefficient of negative thermal expansion of the proposed models is demonstrated to be dependent on the difference between the thermal expansion coefficient of the component materials, as well as on the circular node radius and the ligament length in the antichiral structures. The measured value of the linear negative thermal expansion coefficient of the three-dimensional sample is among the largest achieved in experiments to date. Our findings provide an easy and practical approach to obtaining materials with tunable negative thermal expansion on any scale.

  8. Diagnostic performance of fluorine-18-fluorodeoxyglucose positron emission tomography in the postchemotherapy management of patients with seminoma: systematic review and meta-analysis.

    Science.gov (United States)

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Caldarella, Carmelo; Bertagna, Francesco; Giovanella, Luca

    2014-01-01

    To meta-analyze published data about the diagnostic performance of fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the postchemotherapy management of patients with seminoma. A comprehensive literature search of studies published through January 2014 on this topic was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity and specificity, positive and negative predictive values (PPV and NPV), accuracy, and area under the summary ROC curve (AUC) of (18)F-FDG-PET or PET/CT on a per examination-based analysis were calculated. Subgroup analyses considering the size of residual/recurrent lesions were carried out. Nine studies including 375 scans were selected. The pooled analysis provided the following results: sensitivity 78% (95% confidence interval (95% CI): 67-87%), specificity 86% (95% CI: 81-89%), PPV 58% (95% CI: 48-68%), NPV 94% (95% CI: 90-96%), and accuracy 84% (95% CI: 80-88%). The AUC was 0.90. A better diagnostic accuracy of (18)F-FDG-PET or PET/CT in evaluating residual/recurrent lesions >3 cm compared to those sources of false-negative and false-positive results should be considered. The literature focusing on this setting still remains limited and cost-effectiveness analyses are warranted.

  9. Validity of bacterial pneumonia score for predicting bacteremia in children with pneumonia

    Directory of Open Access Journals (Sweden)

    Rosalia Theodosia Daten Beyeng

    2011-12-01

    Full Text Available Background Bacteremia in children with pneumonia reflects a severe condition, with longer duration of hospital care and potentially lethal complications. Early detection of bacteremia in patients with pneumonia may reduce serious complications. Few bacteremia screening tools have been widely used in chidren with pneumonia. One of those tools is the bacterial pneumonia score (BPS. Objective To assess the validity of the bacterial pneumonia score for predicting bacteremia in pediatric patients with pneumonia. Methods A diagnostic test was conducted on children aged 1 to 60 months hospitalized with pneumonia from December 2009 to August 2010. Subjects were collected consecutively. Pneumonia was diagnosed using the World Healt Organization (WHO criteria. Subjects underwent complete blood counts and blood culture examinations at admission. Statistical analyses included sensitivity, specificity, positive and negative predictive value (PPV/NPV, positive and negative likelihood ratio (PLR/NLR, and post-test probability. Results Our study included 229 children. Based on BPS with a cut-off score of ≥ 4, the sensitivity was 83.3%, specificity 49.7%, PPV 8.4%, NPV 98.2%, PLR 1.66, NLR 0.31, and post-test probability 8.4% for detecting bacteremia in pediatric pneumonia patients. Conclusion BPS can not be used for predicting bacteremia in pediatric patients with pneumonia.

  10. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  11. Positive predictive value and effectiveness of measles case-based surveillance in Uganda, 2012-2015.

    Directory of Open Access Journals (Sweden)

    Fred Nsubuga

    Full Text Available Disease surveillance is a critical component in the control and elimination of vaccine preventable diseases. The Uganda National Expanded Program on Immunization strives to have a sensitive surveillance system within the Integrated Disease Surveillance and Response (IDSR framework. We analyzed measles surveillance data to determine the effectiveness of the measles case-based surveillance system and estimate its positive predictive value in order to inform policy and practice.An IDSR alert was defined as ≥1 suspected measles case reported by a district in a week, through the electronic Health Management Information System. We defined an alert in the measles case-based surveillance system (CBS as ≥1 suspected measles case with a blood sample collected for confirmation during the corresponding week in a particular district. Effectiveness of CBS was defined as having ≥80% of IDSR alerts with a blood sample collected for laboratory confirmation. Positive predictive value was defined as the proportion of measles case-patients who also had a positive measles serological result (IgM +. We reviewed case-based surveillance data with laboratory confirmation and measles surveillance data from the electronic Health Management Information System from 2012-2015.A total of 6,974 suspected measles case-persons were investigated by the measles case-based surveillance between 2012 and 2015. Of these, 943 (14% were measles specific IgM positive. The median age of measles case-persons between 2013 and 2015 was 4.0 years. Between 2013 and 2015, 72% of the IDSR alerts reported in the electronic Health Management Information System, had blood samples collected for laboratory confirmation. This was however less than the WHO recommended standard of ≥80%. The PPV of CBS between 2013 and 2015 was 8.6%.In conclusion, the effectiveness of measles case-based surveillance was sub-optimal, while the PPV showed that true measles cases have significantly reduced in Uganda

  12. Correlation of clinical predictions and surgical results in maxillary superior repositioning.

    Science.gov (United States)

    Tabrizi, Reza; Zamiri, Barbad; Kazemi, Hamidreza

    2014-05-01

    This is a prospective study to evaluate the accuracy of clinical predictions related to surgical results in subjects who underwent maxillary superior repositioning without anterior-posterior movement. Surgeons' predictions according to clinical (tooth show at rest and at the maximum smile) and cephalometric evaluation were documented for the amount of maxillary superior repositioning. Overcorrection or undercorrection was documented for every subject 1 year after the operations. Receiver operating characteristic curve test was used to find a cutoff point in prediction errors and to determine positive predictive value (PPV) and negative predictive value. Forty subjects (14 males and 26 females) were studied. Results showed a significant difference between changes in the tooth show at rest and at the maximum smile line before and after surgery. Analysis of the data demonstrated no correlation between the predictive data and the surgical results. The incidence of undercorrection (25%) was more common than overcorrection (7.5%). The cutoff point for errors in predictions was 5 mm for tooth show at rest and 15 mm at the maximum smile. When the amount of the presurgical tooth show at rest was more than 5 mm, 50.5% of clinical predictions did not match the clinical results (PPV), and 75% of clinical predictions showed the same results when the tooth show was less than 5 mm (negative predictive value). When the amount of presurgical tooth shown in the maximum smile line was more than 15 mm, 75% of clinical predictions did not match with clinical results (PPV), and 25% of the predictions had the same results because the tooth show at the maximum smile was lower than 15 mm. Clinical predictions according to the tooth show at rest and at the maximum smile have a poor correlation with clinical results in maxillary superior repositioning for vertical maxillary excess. The risk of errors in predictions increased when the amount of superior repositioning of the maxilla increased

  13. Value of oral effervescent powder administration for multidetector CT evaluation of esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ringe, Kristina I., E-mail: ringe.kristina@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Meyer, Simone, E-mail: Meyer.simone.rad@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Ringe, Bastian P., E-mail: Ringe.bastian@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Winkler, Michael, E-mail: Winkler.michael@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Wacker, Frank, E-mail: Wacker.frank@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Raatschen, Hans-Juergen, E-mail: Raatschen.hans-juergen@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany)

    2015-02-15

    Highlights: • Oral effervescent powder improves esophageal distension and wall assessment at CT. • This technique improves detection and T staging of esophageal cancer at CT. • It can be easily adopted in clinical routine in patients with esophageal pathology. - Abstract: Purpose: To assess the value of oral effervescent powder (EP) for evaluation of esophageal distension, and for detection and staging of esophageal cancer with contrast-enhanced CT. Materials and methods: 84 patients without esophageal pathology and 52 patients with histological confirmed diagnosis of esophageal cancer were included in this prospective IRB-approved study. Half of the patients in both groups received EP prior to CT. Esophageal distension was assessed by planimetry of the inner (IA) and outer area (OA). Two blinded readers evaluated the datasets separately with regard to diagnosis of esophageal cancer (yes/no) and staging (T0-T4), if applicable. Distension results were compared (t-Test). In patients with cancer sensitivity, specificity, NPV and PPV were calculated. CT staging results were compared to histopathology (Cohen-k). Results: IA and IA/OA were significantly larger after EP as compared to the group without EP (p < 0.05). Sensitivity, specificity, NPV and PPV for cancer detection cancer were as follows: 78%/78%, 98%/98%, 95%/95%, 87%/87% with EP; 60%/68%, 98%/98%, 94%/94%, 80%/83% without EP. Staging with EP was good (k = 0.84/0.67) and moderate without EP (k = 0.58/0.59). Conclusions: Administration of EP prior to CT results in good distension of the esophagus, and improves detection and staging of esophageal cancer, as compared to control studies without EP.

  14. Are Negative Option Prices Possible? The Callable U.S. Treasury-Bond Puzzle.

    OpenAIRE

    Longstaff, Francis A

    1992-01-01

    Market prices for callable Treasury bonds often imply negative values for the implicit call option. The author considers a variety of possible explanations for these negative values including the Treasury's track record in calling bonds optimally, tax-related effects, tax-timing options, and bond liquidity. None of these factors accounts for the negative values. Although the costs of short selling may explain why these apparent arbitrage opportunities persist over time, why these implicit cal...

  15. Diagnostic value of soluble B7-H4 and carcinoembryonic antigen in distinguishing malignant from benign pleural effusion.

    Science.gov (United States)

    Jing, Xiaogang; Wei, Fei; Li, Jing; Dai, Lingling; Wang, Xi; Jia, Liuqun; Wang, Huan; An, Lin; Yang, Yuanjian; Zhang, Guojun; Cheng, Zhe

    2018-03-01

    To explore the diagnostic value of joint detection of soluble B7-H4 (sB7-H4) and carcinoembryonic antigen (CEA) in identifying malignant pleural effusion (MPE) from benign pleural effusion (BPE). A total of 97 patients with pleural effusion specimens were enrolled from The First Affiliated Hospital of Zhengzhou University between June 2014 and December 2015. All cases were categorized into malignant pleural effusion group (n = 55) and benign pleural effusion group (n = 42) according to etiologies. Enzyme-linked immunosorbent assay was applied to examine the levels of sB7-H4 in pleural effusion and meanwhile CEA concentrations were detected by electro-chemiluminescence immunoassays. Receiver operating characteristic (ROC) curve was established to assess the diagnostic value of sB7-H4 and CEA in pleural effusion. The correlation between sB7-H4 and CEA levels was analyzed by Pearson's product-moment. The concentrations of sB7-H4 and CEA in MPE exhibited obviously higher than those of BPE ([60.08 ± 35.04] vs. [27.26 ± 9.55] ng/ml, P = .000; [41.49 ± 37.16] vs. [2.41 ± 0.94] ng/ml, P = .000). The AUC area under ROC curve of sB7-H4 and CEA was 0.884 and 0.954, respectively. Two cutoff values by ROC curve analysis of sB7-H4 36.5 ng/ml and CEA 4.18 ng/ml were obtained, with a corresponding sensitivity (81.82%, 87.28%), specificity (90.48%, 95.24%), accuracy (85.57%, 90.72%), positive predictive value (PPV) (91.84%, 96.0%), negative predictive value (NPV) (79.17%, 85.11%), positive likelihood ratio (PLR) (8.614, 18.327), and negative likelihood ratio (NLR) (0.201, 0.134). When sB7-H4 and CEA were combined to detect pleural effusion, it obtained a higher sensitivity 90.91% and specificity 97.62%. Furthermore, correlation analysis result showed that the level of sB7-H4 was correlated with CEA level (r = .770, P = .000). sB7-H4 was a potentially valuable tumor marker in the differentiation between BPE and MPE. The combined detection of sB7-H4 and

  16. Mammographic findings predicting an extensive intraductal component in early stage invasive breast cancer : analysis on microcalcification

    International Nuclear Information System (INIS)

    Kim, Jeong Ah; Kim, Mi Hye; Lee, Mi Kyung; Oh, Ki Keun; Kim, Eun Kyung

    2000-01-01

    To analyze the mammographic findings of extensive intraductal component (EIC)-positive early invasive breast carcinoma and to determine the mammographic features which predict an EIC positivity in an invasive carcinoma. The mammographic and pathologic findings in 71 patients aged 34-79 (mean 50) years in whom stage I or II invasive breast carcinoma had been diagnosed were retrospectively analysed. The mammographic findings were assigned to one of three groups: mass, mass with microcalcification, or microcalcification only. The shape and distribution of a calcification were classified according to the BI-RADS lexicon, and its extent was classified as either more or less than 3 cm. To detect the presence or absence of EIC and the type of ductal carcinoma in situ (DCIS), the findings were re-examined by means of slide mappings. Twenty-eight of 71 patients (39%) showed ECI positivity. The mammographic findings of EIC-positive invasive cancer (n=3D28) were mass with microcalcification (n=3D14), microcalcification only (n=3D7) and mass only (n=3D7). The mammographic finding which predicted EIC positivity was mass with microcalcification (PPV:0.67, NPV:0.33, p=3D0.02). A mammographic of mass only (n=3D39) showed a significantly high negative predictive value for EIC positivity. (PPV 0.18, NPV 0.82, P less than 0.01). A comparison of cases with or without calcification showed that those with microcalcifications (n=3D32) showed a significantly high PPV of 0.66 (NPV:0.34, p less than 0.01) while those without calcification (n=3D39) showed a significantly high NPV of 0.82 (PPV:0.18, p less than 0.01). There were no significant differences in positive predictive values for EIC between the shape, distribution and extent of calcifications. Whenever microcalcification with or without mass is seen on mammographs obtained during early breast cancer, we can predict EIC-positivity, regardless of shape or distribution according to the BI-RADS lexicon. (author)

  17. Performance of syndromic management for the detection and treatment of genital Chlamydia trachomatis, Neisseria gonorrhoeae and Trichomonas vaginalis among women attending antenatal, well woman and sexual health clinics in Papua New Guinea: a cross-sectional study.

    Science.gov (United States)

    Vallely, Lisa M; Toliman, Pamela; Ryan, Claire; Rai, Glennis; Wapling, Johanna; Gabuzzi, Josephine; Allen, Joyce; Opa, Christine; Munnull, Gloria; Kaima, Petronia; Kombuk, Benny; Kumbia, Antonia; Kombati, Zure; Law, Greg; Kelly-Hanku, Angela; Wand, Handan; Siba, Peter M; Mola, Glen D L; Kaldor, John M; Vallely, Andrew J

    2017-12-29

    Papua New Guinea (PNG) has among the highest estimated prevalences of genital Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) and Trichomonas vaginalis (TV) of any country in the Asia-Pacific region. Diagnosis and treatment of these infections have relied on the WHO-endorsed syndromic management strategy that uses clinical presentation without laboratory confirmation to make treatment decisions. We evaluated the performance of this strategy in clinical settings in PNG. Women attending antenatal (ANC), well woman (WWC) and sexual health (SHC) clinics in four provinces were invited to participate, completed a face-to-face interview and clinical examination, and provided genital specimens for laboratory testing. We estimated the performance characteristics of syndromic diagnoses against combined laboratory diagnoses. 1764 women were enrolled (ANC=765; WWC=614; SHC=385). The prevalences of CT, NG and TV were highest among women attending ANC and SHC. Among antenatal women, syndromic diagnosis of sexually transmitted infection had low sensitivity (9%-21%) and positive predictive value (PPV) (7%-37%), but high specificity (76%-89%) and moderate negative predictive value (NPV) (55%-86%) for the combined endpoint of laboratory-confirmed CT, NG or TV. Among women attending WWC and SHC, 'vaginal discharge syndrome' had moderate to high sensitivity (72%-78%) and NPV (62%-94%), but low specificity (26%-33%) and PPV (8%-38%). 'Lower abdominal pain syndrome' had low sensitivity (26%-41%) and PPV (8%-23%) but moderate specificity (66%-68%) and high NPV (74%-93%) among women attending WWC, and moderate-high sensitivity (67%-79%) and NPV (62%-86%) but low specificity (26%-28%) and PPV (14%-33%) among SHC attendees. The performance of syndromic management for the detection and treatment of genital chlamydia, gonorrhoea and trichomonas was poor among women in different clinical settings in PNG. New diagnostic strategies are needed to control these infections and to prevent

  18. Minimal invasive biopsy results of 'uncertain malignant potential' in digital mammography screening. High prevalence but also high predictive value for malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, S.; Heindel, W. [Universitaetsklinikum Muenster (Germany). Inst. fuer Klinische Radiologie; Universitaetsklinikum Muenster (Germany). Referenzzentrum Mammographie; Decker, T. [Dietrich Bonhoeffer Klinikum, Neubrandenburg (Germany). Inst. fuer Pathologie; Universitaetsklinikum Muenster (Germany). Referenzzentrum Mammographie; Korsching, E. [Universitaetsklinikum Muenster (Germany). Inst. fuer Bioinformatik; Biesheuvel, C.; Woestmann, A.; Boecker, W. [Universitaetsklinikum Muenster (Germany). Referenzzentrum Mammographie; Hungermann, D. [Universitaetsklinikum Muenster (Germany). Gerhard-Domagk-Inst. fuer Pathologie; Roterberg, K.; Tio, J. [Universitaetsklinikum Muenster (Germany). Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe, Bereich Senologie

    2011-08-15

    Purpose: To evaluate the rate, the histological spectrum and the positive predictive value (PPV) for malignancy of minimally invasive biopsies with 'uncertain malignant potential (B3)' in digital mammography screening. Methods and Materials: Consecutive data of 37 178 participants of one digital unit of the German screening program were included. Results: The B 3 rate was 15.1 % (148/979). The frequencies of lesion subtypes were as follows: atypical epithelial proliferation of ductal type (AEPDT) 35.1 % (52/148), radial scar (RS) 28.4 % (42/148), papillary lesions (PAP) 20.3 % (30/148), lobular carcinoma in situ 8.8 % (13/148), flat epithelial atypia 5.4 % (8/148), and mucocele-like lesions 2.0 % (3/148). The PPV for malignancy in surgical excisions was overall 0.28 (25/91); in detail 0.40 (19/47) for AEPDT, 0.20 (5/25) for RS, 0.08 (1/12) for PAP. Conclusion: Despite a higher B 3 rate of minimally invasive biopsies with 'uncertain malignant potential' in digital screening, the benign surgical biopsy rate is not disproportionally increased compared with analog screening programs. Together with defined management protocols, this results in an increased cancer detection rate per screening participant with surgical excision. (orig.)

  19. Diagnostic Performance of Ultra-Low-Dose Computed Tomography for Detecting Asbestos-Related Pleuropulmonary Diseases: Prospective Study in a Screening Setting.

    Science.gov (United States)

    Schaal, Marysa; Severac, François; Labani, Aissam; Jeung, Mi-Young; Roy, Catherine; Ohana, Mickaël

    2016-01-01

    To evaluate the diagnostic performance of Ultra-Low-Dose Chest CT (ULD CT) for the detection of any asbestos-related lesions (primary endpoint) and specific asbestos-related abnormalities, i.e. non-calcified and calcified pleural plaques, diffuse pleural thickening, asbestosis and significant lung nodules (secondary endpoints). 55 male patients (55.7±8.1 years old) with occupational asbestos exposure for at least 15 years and where CT screening was indicated were prospectively included. They all underwent a standard unenhanced chest CT (120kV, automated tube current modulation), considered as the reference, and an ULD CT (135kV, 10mA), both with iterative reconstruction. Two chest radiologists independently and blindly read the examinations, following a detailed protocol. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy and error rate of ULD CT were calculated using the exact method of Pearson with a confidence interval of 95%. Radiation dose was 17.9±1.2mGy.cm (0.25mSv) for the ULD-CT versus 288.8 ±151mGy.cm (4mSv); p value = 100%, negative predictive value = 97.8%), high for lung nodules, diffuse pleural thickening and calcified pleural plaques (sensitivity, specificity, PPV and NPV = 100%) and fair for asbestosis (sensitivity = 75%, specificity = 100%, PPV = 00%, NPV = 98.1%). Intra-reader accuracy between the ULD CT and the reference CT for the primary endpoint was 98% for the senior and 100% for the junior radiologist. Inter-reader agreement for the primary endpoint was almost perfect (Cohen's Kappa of 0.81). ULD CT in the screening of asbestos exposure related diseases has 90.9% sensitivity and 100% specificity, and could therefore be proposed as a first line examination.

  20. Qualidade da avaliação da acuidade visual realizada pelos professores do programa " Olho no olho" da cidade de Marília, SP Assessment of visual acuity evaluation performed by teachers of the "Eye in eye" program in Marília-SP, Brazil

    Directory of Open Access Journals (Sweden)

    Lígia Issa De Fendi

    2008-08-01

    Full Text Available OBJETIVOS: Avaliar a qualidade e o ponto de corte (AV PURPOSE: To assess quality and cut-off point (VA <0.7 of the examinations performed by teachers to detect reduced visual acuity (VA in schoolchildren participants of the project called "Eye in eye " in Marilia-SP, Brazil. METHODS: Visual acuity measurements were performed by trained teachers using Snellen's chart. The children with VA <0.7 in one of the eyes were referred to an ophthalmic examination. The ophthalmic examination was considered gold standard to assess quality and cut-off point of the examinations performed by teachers. VA test was performed in 604 schoolchildren of state public schools (1,208 eyes. Analyses were based on examined eyes. We calculated sensitivity (S, specificity (E, positive predictive value (PPV, negative predictive value (NPV and likelihood rate (LR. We compared the means obtained by the teachers' examinations to means of the ophthalmologist's examinations. ROC curve was produced to evaluate whether VA lower than 0.7 is the best value for referral to an ophthalmic examination. RESULTS: VA means obtained by teachers and ophthalmologic examinations were 0.70 ± 0.16 and 0.88 ± 0.2 respectively. The difference between teachers' and ophthalmologists' examinations was 0.18 (p<0.0001. S, E, PPV, NPV e LR were: 82%, 40%, 27%, 89% and 1.37, respectively. False positive and negative rates were 59.5% and 18%. ROC curve evidenced that visual acuity of 0.7 was the best cut-off point to refer schoolchildren to an ophthalmic exam. CONCLUSIONS: We demonstrated the importance of the teachers' participation in improved schoolchildren ocular health. The examination performed by teachers obtained a satisfactory S with low E, NPV and high values of false positive results. The best cut-off point to refer schoolchildren to an ophthalmic examination was VA of 0.7.

  1. Doppler ultrasound for detection of renal transplant artery stenosis - Threshold peak systolic velocity needs to be higher in a low-risk or surveillance population

    International Nuclear Information System (INIS)

    Patel, U.; Khaw, K.K.; Hughes, N.C.

    2003-01-01

    AIMS: To establish the ideal threshold arterial velocity for the diagnosis of renal transplant artery stenosis in a surveillance population with a low pre-test probability of stenosis. METHODS: Retrospective review of Doppler ultrasound, angiographic and clinical outcome data of patients transplanted over a 3-year period. Data used to calculate sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for various threshold peak systolic velocity values. RESULTS: Of 144 patients transplanted, full data were available in 117 cases. Five cases had renal transplant artery stenosis--incidence 4.2% [stenosis identified at a mean of 6.5 months (range 2-10 months)]. All five cases had a significant arterial pressure gradient across the narrowing and underwent angioplasty. Threshold peak systolic velocity of ≥2.5 m/s is not ideal [specificity=79% (CI 65-82%), PPV=18% (CI 6-32%), NPV=100% (CI 94-100%)], subjecting many patients to unnecessary angiography--8/117 (6%) in our population. Comparable values if the threshold is set at ≥3.0 m/s are 93% (CI 77-96%), 33% (CI 7-44%) and 99% (CI 93-100%), respectively. The clinical outcome of all patients was satisfactory, with no unexplained graft failures or loss. CONCLUSIONS: In a surveillance population with a low pre-test probability of stenosis, absolute renal artery velocity ≥2.5 m/s is a limited surrogate marker for significant renal artery stenosis. The false-positive rate is high, and ≥3.0 m/s is a better choice which will halve the number of patients enduring unnecessary angiography. Close clinical follow-up of patients in the 2.5-3.0 m/s range, with repeat Doppler ultrasound if necessary, will identify the test false-negatives

  2. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  3. Advanced radiological work-up as an adjunct to decision in early reconstructive surgery in brachial plexus injuries

    Directory of Open Access Journals (Sweden)

    Björkman Anders

    2010-07-01

    Full Text Available Abstract Background As neurophysiologic tests may not reveal the extent of brachial plexus injury at the early stage, the role of early radiological work-up has become increasingly important. The aim of the study was to evaluate the concordance between the radiological and clinical findings with the intraoperative findings in adult patients with brachial plexus injuries. Methods Seven consecutive male patients (median age 33; range 15-61 with brachial plexus injuries, caused by motor cycle accidents in 5/7 patients, who underwent extensive radiological work-up with magnetic resonance imaging (MRI, computed tomography myelography (CT-M or both were included in this retrospective study. A total of 34 spinal nerve roots were evaluated by neuroradiologists at two different occasions. The degree of agreement between the radiological findings of every individual nerve root and the intraoperative findings was estimated by calculation of kappa coefficient (К-value. Using the operative findings as a gold standard, the accuracy, sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of the clinical findings and the radiological findings were estimated. Results The diagnostic accuracy of radiological findings was 88% compared with 65% for the clinical findings. The concordance between the radiological findings and the intraoperative findings was substantial (К = 0.76 compared with only fair (К = 0.34 for the clinical findings. There were two false positive and two false negative radiological findings (sensitivity and PPV of 0.90; specificity and NPV of 0.87. Conclusions The advanced optimized radiological work-up used showed high reliability and substantial agreement with the intraoperative findings in adult patients with brachial plexus injury.

  4. Clinical performance of a new point-of-care cardiac troponin I test.

    Science.gov (United States)

    Christ, Michael; Geier, Felicitas; Blaschke, Sabine; Giannitsis, Evangelos; Khellaf, Mehdi; Mair, Johannes; Pariente, David; Scharnhorst, Volkher; Semjonow, Veronique; Hausfater, Pierre

    2018-04-09

    We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR-) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.

  5. The value of virtual touch tissue image (VTI) and virtual touch tissue quantification (VTQ) in the differential diagnosis of thyroid nodules

    International Nuclear Information System (INIS)

    Zhang, Feng-Juan; Han, Ruo-Ling; Zhao, Xin-Ming

    2014-01-01

    Highlights: • All nodules in the research were confirmed by histopathology. • The classification method of VTI was easy to learn. • VTQ could provide quantitative elasticity measurements for thyroid nodules. • VTI classification could provide semi-quantitative elasticity analysis. • The area ratio could show invasive extent of malignant tumor. - Abstract: Objectives: To explore the value of virtual touch tissue image (VTI) and virtual touch tissue quantification (VTQ) in the differential diagnosis of thyroid nodules. Methods: One-hundred and seven patients with 113 thyroid nodules were performed conventional ultrasound and acoustic radiation force impulse (ARFI) elastography. The stiffness of the nodules on virtual touch tissue image (VTI) was graded, and the area ratios (AR) of nodules on VTI images versus on B-mode images were calculated. Shear wave velocity (SWV) within the thyroid nodules were measured using virtual touch tissue quantification (VTQ) technique. The pathological diagnosis as the gold standard draws the receiver-operating characteristic curve (ROC) to find the cut-off point of VTI grades, AR and SWV to predict thyroid cancer. Results: The difference in VTI grades of malignant and benign nodules was statistically significant (P < 0.05), as well as in AR and SWV. There was no significant difference in the AR of nodules or the SWV of nodules in benign group or in malignant group. The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of VTI grades, AR, and SWV in the differential diagnosis of thyroid nodules were calculated. There was no significant difference in diagnostic accuracy among the three methods. Conclusion: VTI grades, AR of nodules on VTI images versus on B-mode images and SWV within the nodules can help the differential diagnosis of thyroid nodules

  6. Health significance and statistical uncertainty. The value of P-value.

    Science.gov (United States)

    Consonni, Dario; Bertazzi, Pier Alberto

    2017-10-27

    The P-value is widely used as a summary statistics of scientific results. Unfortunately, there is a widespread tendency to dichotomize its value in "P0.05" ("statistically not significant"), with the former implying a "positive" result and the latter a "negative" one. To show the unsuitability of such an approach when evaluating the effects of environmental and occupational risk factors. We provide examples of distorted use of P-value and of the negative consequences for science and public health of such a black-and-white vision. The rigid interpretation of P-value as a dichotomy favors the confusion between health relevance and statistical significance, discourages thoughtful thinking, and distorts attention from what really matters, the health significance. A much better way to express and communicate scientific results involves reporting effect estimates (e.g., risks, risks ratios or risk differences) and their confidence intervals (CI), which summarize and convey both health significance and statistical uncertainty. Unfortunately, many researchers do not usually consider the whole interval of CI but only examine if it includes the null-value, therefore degrading this procedure to the same P-value dichotomy (statistical significance or not). In reporting statistical results of scientific research present effects estimates with their confidence intervals and do not qualify the P-value as "significant" or "not significant".

  7. The value of repeat scintigraphy in patients with a high clinical suspicion for Meckel diverticulum after a negative or equivocal first Meckel scan

    Energy Technology Data Exchange (ETDEWEB)

    Vali, Reza; Daneman, Alan; McQuattie, Susan; Shammas, Amer [Hospital for Sick Children, Diagnostic Imaging, Toronto (Canada)

    2015-09-15

    Technetium {sup 99m}Tc-pertechnetate is the most common and accurate noninvasive method of preoperative investigation for Meckel diverticulum. Despite introducing various methods to increase the sensitivity of the study, there are many case reports of false-negative Meckel scans. A repeat scan is sometimes requested in patients with a high suspicion for Meckel diverticulum and negative or equivocal first Meckel scan. The purpose of this retrospective study is to evaluate the value of repeat scintigraphy for these patients. Seven hundred fifty-three Meckel scans were recorded retrospectively. In 33 cases (22 male and 11 female; mean age: 6.8 years), the Meckel scintigraphy was repeated either due to a high clinical suspicion of Meckel diverticulum and a negative study (n = 21) or due to equivocal findings in the first scan (n = 12). The study was interpreted as positive if an abnormal focal activity was identified in the abdomen and pelvis during the procedure. The results were correlated with pathology and clinical symptoms. Seven out of 12 (58%) equivocal studies were positive on the second study. Six of them were proven to be positive at operation (confirmed by pathology) while one of them was negative on laparoscopy. From 21 negative first scans with a high suspicion for Meckel diverticulum, three (14%) were positive on the second study. All three were proven to be Meckel diverticulum on pathology. Repeat Meckel scans in patients with equivocal findings on the first study or a negative result with a high clinical suspicion for a Meckel diverticulum are useful especially in cases in which the first study had been done without appropriate preparation. (orig.)

  8. Role of specimen US for predicting resection margin status in breast conserving therapy.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G

    2015-01-01

    To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.

  9. Identification of new negative-parity levels in 152,154Nd

    International Nuclear Information System (INIS)

    Zhang, X.Q.; Hamilton, J.H.; Ramayya, A.V.; Peker, L.K.; Hwang, J.K.; Jones, E.F.; Komicki, J.; Beyer, C.J.; Gore, P.M.; Babu, B.R.; Ginter, T.N.; Ter-Akopian, G.M.; Daniel, A.V.; Asztalos, S.J.; Chu, S.Y.; Gregorich, K.E.; Lee, I.Y.; Macchiavelli, A.O.; Macleod, R.W.; Rasmussen, J.O.; Gilat, J.; Ter-Akopian, G.M.; Oganessian, Y.T.; Daniel, A.V.; Ter-Akopian, G.M.; Daniel, A.V.; Ma, W.C.; Varmette, P.G.; Cole, J.D.; Aryaeinejad, R.; Butler-Moore, K.; Dardenne, Y.X.; Drigert, M.W.; Stoyer, M.A.; Wild, J.F.; Becker, J.A.; Bernstein, L.A.; Lougheed, R.W.; Moody, K.J.; Donangelo, R.; Prussin, S.G.; Griffin, H.C.

    1998-01-01

    From an experiment with Gammasphere and a 252 Cf spontaneous fission source, a new negative-parity band in 154 Nd and new negative-parity levels in 152 Nd were identified and the yrast bands were extended to 18 + in 154 Nd and 20 + in 152 Nd in a triple gamma coincidence study. These new negative-parity bands are consistent with octupole vibrational mode. There is a constant difference as a function of spin between the J 1 values for the negative-parity band in 152 Nd and J 1 for the similar negative-parity band in 154 Nd, however, their J 2 values are essentially identical. These bands indicate a new kind of identical band. copyright 1998 The American Physical Society

  10. Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements.

    Science.gov (United States)

    Ascenti, Giorgio; Mileto, Achille; Krauss, Bernhard; Gaeta, Michele; Blandino, Alfredo; Scribano, Emanuele; Settineri, Nicola; Mazziotti, Silvio

    2013-08-01

    To compare the diagnostic accuracy of iodine quantification and standard enhancement measurements in distinguishing enhancing from nonenhancing renal masses. The Institutional Review Board approved this retrospective study conducted from data found in institutional patient databases and archives. Seventy-two renal masses were characterised as enhancing or nonenhancing using standard enhancement measurements (in HU) and iodine quantification (in mg/ml). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of standard enhancement measurements and iodine quantification were calculated from χ (2) tests of contingency with histopathology or imaging follow-up as the reference standard. Difference in accuracy was assessed by means of McNemar analysis. Sensitivity, specificity, PPV, NPV and diagnostic accuracy for standard enhancement measurements and iodine quantification were 77.7 %, 100 %, 100 %, 81.8 %, 89 % and 100 %, 94.4 %, 94.7, 100 % and 97 %, respectively. The McNemar analysis showed that the accuracy of iodine quantification was significantly better (P < 0.001) than that of standard enhancement measurements. Compared with standard enhancement measurements, whole-tumour iodine quantification is more accurate in distinguishing enhancing from nonenhancing renal masses. • Enhancement of renal lesions is important when differentiating benign from malignant tumours. • Dual-energy CT offers measurement of iodine uptake rather than mere enhancement values. • Whole-tumour iodine quantification seems more accurate than standard CT enhancement measurements.

  11. Understanding and overcoming the “positive profits with negative surplus-value” paradox

    Directory of Open Access Journals (Sweden)

    GUSTAVO DAOU LUCAS

    Full Text Available ABSTRACT This paper explains the “positive profits with negative surplus-value” example of Steedman (1975 and shows that while in joint production systems individual labour values can be negative, the claim that the total labour embodied in the surplus product of the economy (surplus-value can also be negative is based on assumptions that have no economic meaning (such as negative activity levels.The paper also provides a way to measure the surplus-value of joint production systems which overcomes the problems of the traditional concept and restates the proposition that a positive amount of surplus labour is a necessary condition for positive profits.

  12. Simplification of childhood hypertension definition using blood pressure to height ratio among US youths aged 8-17years, NHANES 1999-2012.

    Science.gov (United States)

    Xi, Bo; Zhang, Meixian; Zhang, Tao; Li, Shuangshuang; Steffen, Lyn M

    2015-02-01

    The fourth report on the diagnosis, evaluation, and treatment of high blood pressure (BP) established high BP diagnostic criteria using age-, sex-, and height-specific BP percentiles. However, these BP criteria are quite difficult for use by professionals in the clinic or children and their parents. We aimed to simplify the hypertension diagnostic criteria using BP to height ratio (BP/height) in US children and adolescents aged 8-17years. Data were obtained from a national representative sample of 14,624 US children and adolescents aged 8-17years enrolled in the continuous National Health and Nutrition Examination Survey 1999-2012. SBP to height ratio (SBPHR) was calculated as SBP (mmHg)/height (cm) and DBP to height ratio (DBPHR) was calculated as DBP (mmHg)/height (cm). The BP diagnostic criteria recommended by the fourth report were used as the "gold standard". Receive operator characteristic curve analysis was used to choose the optimal thresholds of SBPHR and DBPHR. The optimal thresholds for identifying pre-hypertension and hypertension among children aged 8-12years and adolescents aged 13-17years were determined. The negative predictive value (NPV) for identifying hypertension was nearly 100% for both children and adolescents, although the positive predictive value (PPV) ranged from 19% to 35%. The NPV for identifying pre-hypertension ranged from 95% to 99% for children and adolescents, and the PPV ranged from 11% to 52%. The optimal thresholds of SBPHR and DBPHR are simple and accurate for screening elevated BP, although PPV is relatively low because of the low prevalence of childhood hypertension. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  14. External Validity of Electronic Sniffers for Automated Recognition of Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    McKown, Andrew C; Brown, Ryan M; Ware, Lorraine B; Wanderer, Jonathan P

    2017-01-01

    Automated electronic sniffers may be useful for early detection of acute respiratory distress syndrome (ARDS) for institution of treatment or clinical trial screening. In a prospective cohort of 2929 critically ill patients, we retrospectively applied published sniffer algorithms for automated detection of acute lung injury to assess their utility in diagnosis of ARDS in the first 4 ICU days. Radiographic full-text reports were searched for "edema" OR ("bilateral" AND "infiltrate") and a more detailed algorithm for descriptions consistent with ARDS. Patients were flagged as possible ARDS if a radiograph met search criteria and had a PaO 2 /FiO 2 or SpO 2 /FiO 2 of 300 or 315, respectively. Test characteristics of the electronic sniffers and clinical suspicion of ARDS were compared to a gold standard of 2-physician adjudicated ARDS. Thirty percent of 2841 patients included in the analysis had gold standard diagnosis of ARDS. The simpler algorithm had sensitivity for ARDS of 78.9%, specificity of 52%, positive predictive value (PPV) of 41%, and negative predictive value (NPV) of 85.3% over the 4-day study period. The more detailed algorithm had sensitivity of 88.2%, specificity of 55.4%, PPV of 45.6%, and NPV of 91.7%. Both algorithms were more sensitive but less specific than clinician suspicion, which had sensitivity of 40.7%, specificity of 94.8%, PPV of 78.2%, and NPV of 77.7%. Published electronic sniffer algorithms for ARDS may be useful automated screening tools for ARDS and improve on clinical recognition, but they are limited to screening rather than diagnosis because their specificity is poor.

  15. Is MRI helpful in assessing the distance of the tumour from the internal os in patients with cervical cancer below FIGO Stage IB2?

    International Nuclear Information System (INIS)

    Bhosale, P.R.; Iyer, R.B.; Ramalingam, P.; Schmeler, K.M.; Wei, W.; Bassett, R.L.; Ramirez, P.T.; Frumovitz, M.

    2016-01-01

    Aim: To determine the ability of magnetic resonance imaging (MRI) in detecting tumour-free margins from the internal os (IO). Materials and methods: A database search yielded 79 women with early-stage cervical cancer who underwent radical hysterectomy and preoperative MRI. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of MRI in assessment of ≤5 and >5 mm IO involvement were calculated with histopathological surgical specimen findings considered to be the reference standard. A main and subset analysis was performed. The subset analysis included only those patients who would have been considered for radical trachelectomy. Results: For predicting a distance between the tumour and the IO of ≤5 mm, MRI had a sensitivity of 73%, a specificity of 98.3%, a PPV of 95%, a NPV of 88.1%, and an accuracy of 89.8% for the main analysis, and sensitivity of 81.8%, a specificity of 93.2% a PPV of 69.2% a NPV of 96.5% and an accuracy of 91.4% for the subset analysis. Conclusion: MRI has high specificity, NPV, and accuracy in detecting tumour from the IO, making MRI suitable for treatment planning in patients desiring trachelectomy to preserve fertility. - Highlights: • Cervical cancer patients who underwent hysterectomy were analyzed on MRI and pathology for involvement of the internal os. • Distance of the tumor from the internal-os was measured on MRI and Pathology and findings were tabulated as > and ≤ 5 mm from the internal os. • MRI has the ability to identify tumor involvement of the internal os. • MRI can help select patients who can undergo trachelectomy safely.

  16. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  17. Superconductive microstrip exhibiting negative differential resistivity

    International Nuclear Information System (INIS)

    Huebener, R.P.; Gallus, D.E.

    1975-01-01

    A device capable of exhibiting negative differential electrical resistivity over a range of values of current and voltage is formed by vapor-depositing a thin layer of a material capable of exhibiting superconductivity on an insulating substrate, establishing electrical connections at opposite ends of the deposited strip, and cooling the alloy into its superconducting range. The device will exhibit negative differential resistivity when biased in the current-induced resistive state

  18. The significance of fertile pigs vaccination against porcine parvovirus infection in the prevention of intrauterine infection and formation of colostrum piglets immunity

    Directory of Open Access Journals (Sweden)

    Stojanac Nenad

    2014-01-01

    Full Text Available The aim of this study was to come closer to the knowledge of piglets protection during intrauterine life, as well as formation of colostrum immunity against Porcine Parvovirus Infection (PPV, on the basis of detailed antibody titer analysis from the blood serum of pigs 7 days before previous weaning, 30 days before mating and their piglets during first 3 days of life. The research included 60 fertile pigs and 300 of their offspring. For that purpose we have examined antibody titer specific for PPV in blood serum of vaccinated fertile pigs on 70th and 113th day of gestation, and in the blood serum of piglets originated from itemized fertile pigs during first day of life, before colostrums consummation and also during 3rd day of life. On the 70th day of gestation, in the fertile pigs blood serum, average antibody titer specific for PPV, value of 12.60 was determined, what represents adequate level for solid protection against PPV infection. This was confirmed undoubtedly by examination results of antibodies in the blood serum of piglets before colostrum consummation, which was 100% negative. Titer drop in the blood serum of fertile pigs, on 113th day of gestation (on the level of 8.7 came as a result of specific antibodies transfer from the mother’s blood flow to the colostrum. The above-mentioned is supported by the fact that on the 3rd day of life there was confirmed high average body titer level (13.37 in newborn piglets body serum has been confirmed. The principle of fertile pigs vaccination 7 days before weaning and one month before gilts insemination is an efficient measure which prevents intrauterine infection occurrence during the entire gestation process. The level of antibodies specific for PPV which is determined in gilts blood serum after vaccination can be a result of both primary and secondary immune response (animal infected before first vaccination, as well as absence of gilts revaccination, what is usually recommended by

  19. Meta-analysis comparing same-day versus delayedvitrectomy clinical outcomes for intravitreal retained lens fragments after age-relatedcataract surgery

    Directory of Open Access Journals (Sweden)

    Vanner EA

    2014-11-01

    Full Text Available Elizabeth A Vanner,1 Michael W Stewart21Department of Preventive Medicine, Pathology and Bioinformatics, Stony Brook University, Stony Brook, NY, USA; 2Department of Ophthalmology, Mayo Clinic College of Medicine, Jacksonville, FL, USAPurpose/design: We aimed to perform a systematic review and meta-analysis comparing the risk difference of clinical outcomes for same-day (SD vs delayed (DEL pars plana vitrectomy (PPV.Methods: We searched MEDLINE (English; January 1, 1985 to July 16, 2013 and article reference lists, for patients with crystalline retained lens fragments and discussion of SD-PPV vs DEL-PPV. For the meta-analysis, articles needed the number of patients receiving SD-PPV and DEL-PPV, and the number, in each group, who experienced one or more of the outcomes: not good visual acuity (VA (<20/40, bad VA (≤20/200, retinal detachment, increased intraocular pressure/glaucoma, intraocular infection/inflammation, cystoid macular edema, and corneal edema.Results: Of 304 articles identified, 23 provided data for the meta-analysis. Results were mixed, indicating 1 neither vitrectomy time produced better outcomes in all studies (not good VA risk difference =10.3% [positive numbers favored SD-PPV; negative numbers favored DEL-PPV], 95% confidence interval [CI] = [-0.4% to 21.0%], P=0.059; and bad VA risk difference =-0.3%, 95% CI = [-10.7% to 10.1%], P=0.953; 2 better outcomes with immediate SD-PPV compared with all DEL-PPV (not good VA risk difference =16.2%, 95% CI = [0.8% to 31.5%], P=0.039; and bad VA risk difference =8.5%; 95% CI = [0.8% to 16.2%], P=0.030; and 3 immediate SD-PPV and prompt DEL-PPV (3 to 14 days after cataract surgery had no significant differences and so may produce similar outcomes (not good VA risk differences range = [-19.9% to 6.5%], 95% CI = [-59.9% to 36.4%]; and bad VA risk differences range = [-6.9% to 7.4%], 95% CI = [-33.1% to 31.8%].Conclusion: Perhaps SD-PPV should be limited to facilities at which a

  20. Combination of serum angiopoietin-2 and uterine artery Doppler for prediction of preeclampsia.

    Science.gov (United States)

    Puttapitakpong, Ploynin; Phupong, Vorapong

    2016-02-01

    The aim of this study was to determine the predictive value of the combination of serum angiopoietin-2 (Ang-2) levels and uterine artery Doppler for the detection of preeclampsia in women at 16-18 weeks of gestation and to identify other pregnancy complications that could be predicted with these combined tests. Maternal serum Ang-2 levels were measured, and uterine artery Doppler was performed in 400 pregnant women. The main outcome was preeclampsia. The predictive values of this combination were calculated. Twenty-five women (6.3%) developed preeclampsia. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of uterine artery Doppler combined with serum Ang-2 levels for the prediction of preeclampsia were 24.0%, 94.4%, 22.2% and 94.9%, respectively. For the prediction of early-onset preeclampsia, the sensitivity, specificity, PPV and NPV were 57.1%, 94.1%, 14.8% and 99.2%, respectively. Patients with abnormal uterine artery Doppler and abnormal serum Ang-2 levels (above 19.5 ng ml(-1)) were at higher risk for preterm delivery (relative risk=2.7, 95% confidence interval 1.2-5.8). Our findings revealed that the combination of uterine artery Doppler and serum Ang-2 levels at 16-18 weeks of gestation can be used to predict early-onset preeclampsia but not overall preeclampsia. Thus, this combination may be a useful early second trimester screening test for the prediction of early-onset preeclampsia.

  1. Reliability and validity of a Chinese version of the HADS for screening depression and anxiety in psycho-cardiological outpatients.

    Science.gov (United States)

    Yang, Yuan; Ding, Rongjing; Hu, Dayi; Zhang, Fan; Sheng, Li

    2014-01-01

    The Hospital Anxiety and Depression Scale (HADS) has been used widely with cardiovascular patients. This study aims to examine the reliability and validity of a Chinese version of HADS among psycho-cardiological outpatients. One hundred psycho-cardiological outpatients were asked to complete the Chinese version of HADS and were then interviewed according to the Mini International Neuropsychiatric Interview, Version 5 (MINI). According to the MINI, 38 outpatients were diagnosed with major depression and 15 outpatients were diagnosed with an anxiety disorder. Compared with the MINI diagnoses, the optimum cutoff value of the anxiety subscale (HADS-A) was six (6) with a sensitivity of 81.6%, specificity of 75.8%, positive predictive value (PPV) of 54.0% and negative predictive value (NPV) of 91.9%; at the optimum cutoff value of nine (9), the depression subscale (HADS-D) had a sensitivity of 80.0%, specificity of 92.9%, PPV of 52.2% and NPV of 96.1%. The Cronbach's alpha coefficients of the HADS-A and HADS-D subscales were 0.753 and 0.764, respectively. The areas under the ROC curves of the HADS-A and the HADS-D subscales, as compared to MINI diagnoses of anxiety and depression, were 0.81 (SE = 0.05, 95%CI: [0.73, 0.90]) and 0.86 (SE = 0.05, 95%CI: [0.77, 0.94]), respectively. The HADS was found to be a reliable measurement tool for excluding depression and anxiety in psycho-cardiological outpatients. © 2014.

  2. Value of 201Tl imaging in predicting therapeutic 131I uptake in patients with thyroglobulin-positive but 131I scan-negative differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Conlu, R.A.O.; Obaldo, J.M.

    2004-01-01

    Background: Serum thyroglobulin assay and 131Iodine (1311) whole body scan are considered complementary in detecting malignant thyroid tissue or metastases. A large number of patients, however, are encountered presenting with scan-negative, thyroglobulin-positive differentiated thyroid carcinoma posing a dilemma in therapeutic management. One of the first alternative scanning agents to be employed is 201Thallium (201Tl). Recent studies have demonstrated its usefulness in identifying lesions that are not visualized with traditional 131I whole body scan. It is not clear, however, whether 201Tl scan helps in the decision-making for subsequent 131I therapy. This study was conducted to determine if 201Tl scan can predict therapeutic 131I uptake and to define the clinical role of 201Tl scanning in these patients. Methods and results: A total of 12 patients (20-63 y/o), 5 males and 7 females, underwent surgery for differentiated thyroid cancer and all had serum thyroglobulin values above 10 ng/ml and normal TPO autoantibodies. Pre-therapy 131I scan using 111 MBq (3mCi) of 131I were obtained. As required for inclusion, all patients had negative pre-therapy scan and negative TPO autoantibody results and underwent 20lTl scanning within 3 weeks. All patients were given 131I therapy (3.7-5.5 GBq or 100-150 mCi) between one to two months after 201Tl scanning. Within a week after therapy, all patients underwent whole body 1311 scanning. 201Tl imaging demonstrated thyroid remnants in 9 out of 12 patients having positive 201Tl scan but negative pre-therapy 1311 scan. However, only 2 of the positive 201Tl scans showed 131I uptake post-therapy (positive predictive value of 20%). None of the subjects presented with a negative 201Tl scan and a positive post-therapy 131I scan. Conclusion: Our study suggests that evidence of remnants or metastases on 201Tl scanning may be an inappropriate basis for the decision to proceed with 131I therapy. The role of 20lTl imaging in this subset of

  3. Mining of high utility itemsets of size-2 with pruning strategies and negative item values for B2C companies based on experiential marketing approach

    Directory of Open Access Journals (Sweden)

    Gaurav Gahlot

    2016-09-01

    Full Text Available Business to customer (B2C marketing for the retail organisations is the most rapid adoption made by the developed countries, while it has the pitfalls in the developing nations. B2C companies have been continually putting some or the other lucrative offers and schemes on their manufactured products. There happens to be no logical demand of clubbing the sale of two products. The only need of such clubbing is the financial crisis which the company wants to overcome. Information technology can renew and make the competitive advantage for B2C companies. In this paper, a novel way for finding the itemset clubs is proposed, hence extending Apriori algorithm. The proposed methodology aims at finding the combinations of the products which can be sold together with the high levels of utility. This allows for making good profits for the company. Unlike contemporary way of items bearing positive values, negative item values have been looked into. The MHUIS-2wPS algorithm utilises the transactional experiences of the retail stores and outputs the size-2 clubs. The MHUI-NIV algorithm caters for the items with negative item values. The dissertation applies various pruning strategies for the discovery of high utility itemsets. These prunings will help remove the unnecessary formation of the low utility extensions. Later, various datasets have been used to show the essence of the algorithms.

  4. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  5. [Hospitalizations for ambulatory care-sensitive conditions: validation study at a Hospital Information System (SIH) in the Federal District, Brazil, in 2012].

    Science.gov (United States)

    Cavalcante, Danyelle Monteiro; de Oliveira, Maria Regina Fernandes; Rehem, Tânia Cristina Morais Santa Bárbara

    2016-03-01

    This study analyzes hospitalizations due to ambulatory care-sensitive conditions with a focus on infectious and parasitic diseases (IPDs) and validates the Hospital Information System, Brazilian Unified National Health System (SIH/SUS) for recording hospitalizations due to ambulatory care-sensitive conditions in a hospital in the Federal District, Brazil, in 2012. The study estimates the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the SIH for recording hospitalizations due to ambulatory care-sensitive conditions, with the patient's medical file as the gold standard. There were 1,604 hospitalizations for hospitalizations due to ambulatory care-sensitive conditions (19.6%, 95%CI: 18.7-20.5), and the leading IPDs were renal and urinary tract infection, infection of the skin and subcutaneous tissue, and infectious gastroenteritis. IPDs were the leading cause of hospitalization in the 20 to 29-year age bracket and caused 28 deaths. Sensitivity was 70.1% (95%CI: 60.5-79.7), specificity 88.4% (95%CI: 85.6-91.2), PPV = 51.7% (95%CI: 42.7-60.7), and NPV = 94.3% (95%CI: 92.2-96.4). The findings for admissions due to ACSCs in this hospital were similar to those of other studies, featuring admissions for IPDs. The SIH/SUS database was more specific than sensitive.

  6. Comparison between MRI with MR cholangiopancreatography and endoscopic ultrasonography for differentiating malignant from benign mucinous neoplasms of the pancreas

    International Nuclear Information System (INIS)

    Hwang, Jiyoung; Hong, Seong Sook; Kim, Hyun-joo; Kim, Young Kon; Jeong, Woo Kyung; Min, Ji Hye

    2018-01-01

    To compare diagnostic performance of magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS) for differentiating malignant from benign intraductal papillary mucinous neoplasms (IPMN) and mucinous cystic neoplasms (MCN) of the pancreas. This retrospective study included 55 patients with 47 surgically confirmed IPMNs (12 malignant, 35 benign) and eight MCNs (two malignant, six benign) who underwent contrast-enhanced pancreas MRI and EUS. Contrast enhancement was not routinely used at EUS examination. Two observers independently evaluated the MRIs, and another reviewed EUS images. They recorded their confidence for malignancy with each imaging modality. We calculated diagnostic performance using the area under the receiver operating characteristic curves (A z ), and to determine the accuracy, sensitivity, specificity, and positive (PPV) and negative predictive (NPV) values. The A z values of MRI were higher than those of EUS (0.712 and 0.688 for MRI vs. 0.543 for EUS; p = 0.007). The diagnostic accuracies (74.5%), specificity (78.0% and 80.5%) and PPV (50.0%) of MRI in two observers were higher than those (56.4%, 58.5% and 29.2%, respectively) of EUS (p = 0.013-0.049). MRI showed better diagnostic performance than EUS for differentiating malignant from benign pancreatic IPMN and MCN. (orig.)

  7. Detection of Trichomonas Vaginalis Infection in Male Non-gonococcal Urethritis Patients by InPouch TV Culture and Polymerase Chain Reaction

    Institute of Scientific and Technical Information of China (English)

    YAO Zhiyuan(姚志远); ZHENG Heyi(郑和义); CAO Jingjiang(曹经江)

    2002-01-01

    Objective: To study the prevalence of Trichomonas vaginalis(TV) infection in Chinese male patients with nongonococcalurethritis (NGU), to evaluate the sensitivity and specificity ofurine-based and urethral swab polymerase chain reaction(PCR) detection, to set up a method for non-invasive detectionof male TV infection. Method: One hundred and five male NGU patients wereselected from a Beijing STD clinic. Two urethral swabs wereobtained from each patient, one for the InPouch TV culturesystem and the other for PCR. In addition, one first void urinespecimen was collected for PCR detection. Culture wasconsidered the "gold standard". The sensitivity, specificity,positive predictive value (PPV) and negative predictive value(NPV) of the two PCR detections were compared to cultureresults. Results: The prevalence of urine-based PCR and urethralswab PCR detection was 3.81% (4/105) and 4.76% (5/105)respectively. Compared to culture, the sensitivity, specificity,PPV and NPV were 80%, 100%, 100% and 99% for urine-based PCR and 80%, 99%, 80% and 99% for urethral swabPCR.Conclusion: TV is one of the etiological agents in male NGU,with a 4.76% prevalence of infection in our study. The urine-based PCR detection has higher sensitivity and specificity andprovides a noninvasive method more feasible in practice.

  8. Peristalsis gap sign at cine magnetic resonance imaging for diagnosing strangulated small bowel obstruction. Feasibility study

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, T.C.; Haradome, Hiroki

    2011-01-01

    The aim of this study was to determine the feasibility of cine magnetic resonance imaging (MRI) for diagnosing strangulated small bowel obstruction (SBO). This study included 38 patients with clinically confirmed SBO who had undergone cine MRI. Cine MRI scans were evaluated regarding the presence of the 'peristalsis gap sign' (referring to an akinetic or severely hypokinetic closed loop), indicating strangulation. Computed tomography (CT) was performed in 34 of 38 patients with (n=25) or without (n=9) contrast enhancement. CT images were evaluated using a combination of criteria (presence of hyperattenuation, poor contrast enhancement, mesenteric edema, wall thickening, massive ascites) indicating strangulation. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of cine MRI and CT for the diagnosis of strangulation were calculated and compared using surgical findings and the clinical course as the reference standard. Sensitivity, specificity, PPV, and NPV of cine MRI were 100%, 92.9%, 83.3%, and 100%, respectively; and those of CT (of which 26.5% was performed without contrast enhancement) were 66.7%, 92.0%, 75.0%, and 88.5%, respectively. There was no significant difference in diagnostic accuracy between the two methods (P=0.375). Cine MRI is a feasible and promising technique for diagnosing strangulation. (author)

  9. A new spirometry-based algorithm to predict occupational pulmonary restrictive impairment.

    Science.gov (United States)

    De Matteis, S; Iridoy-Zulet, A A; Aaron, S; Swann, A; Cullinan, P

    2016-01-01

    Spirometry is often included in workplace-based respiratory surveillance programmes but its performance in the identification of restrictive lung disease is poor, especially when the prevalence of this condition is low in the tested population. To improve the specificity (Sp) and positive predictive value (PPV) of current spirometry-based algorithms in the diagnosis of restrictive pulmonary impairment in the workplace and to reduce the proportion of false positives findings and, as a result, unnecessary referrals for lung volume measurements. We re-analysed two studies of hospital patients, respectively used to derive and validate a recommended spirometry-based algorithm [forced vital capacity (FVC) 55%] for the recognition of restrictive pulmonary impairment. We used true lung restrictive cases as a reference standard in 2×2 contingency tables to estimate sensitivity (Sn), Sp and PPV and negative predictive values for each diagnostic cut-off. We simulated a working population aged spirometry-based algorithm may be adopted to accurately exclude pulmonary restriction and to possibly reduce unnecessary lung volume testing in an occupational health setting. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Comparison between MRI with MR cholangiopancreatography and endoscopic ultrasonography for differentiating malignant from benign mucinous neoplasms of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jiyoung; Hong, Seong Sook; Kim, Hyun-joo [Seoul Hospital, Department of Radiology, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Kim, Young Kon; Jeong, Woo Kyung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Min, Ji Hye [Chungnam National University College of Medicine, Department of Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2018-01-15

    To compare diagnostic performance of magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS) for differentiating malignant from benign intraductal papillary mucinous neoplasms (IPMN) and mucinous cystic neoplasms (MCN) of the pancreas. This retrospective study included 55 patients with 47 surgically confirmed IPMNs (12 malignant, 35 benign) and eight MCNs (two malignant, six benign) who underwent contrast-enhanced pancreas MRI and EUS. Contrast enhancement was not routinely used at EUS examination. Two observers independently evaluated the MRIs, and another reviewed EUS images. They recorded their confidence for malignancy with each imaging modality. We calculated diagnostic performance using the area under the receiver operating characteristic curves (A{sub z}), and to determine the accuracy, sensitivity, specificity, and positive (PPV) and negative predictive (NPV) values. The A{sub z} values of MRI were higher than those of EUS (0.712 and 0.688 for MRI vs. 0.543 for EUS; p = 0.007). The diagnostic accuracies (74.5%), specificity (78.0% and 80.5%) and PPV (50.0%) of MRI in two observers were higher than those (56.4%, 58.5% and 29.2%, respectively) of EUS (p = 0.013-0.049). MRI showed better diagnostic performance than EUS for differentiating malignant from benign pancreatic IPMN and MCN. (orig.)

  11. Bone scan and joint scan of hands and feet in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Carpentier, N.; Verbeke, S.; Perdrisot, R.; Grilo, R.M.; Quenesson, E.; Bonnet, C.; Vergne, P.; Treves, R.; Bertin, P.; Boutros-Toni, F.

    2000-01-01

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate 99m Tc intravenous injection. Patients were scanned 5 minutes (tissual time, T t ) and 3 hours 1/4 (bone time, T 0 ) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of 99m Tc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T 0 . The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)

  12. Evaluating the negative or valuing the positive? Neural mechanisms supporting feedback-based learning across development.

    Science.gov (United States)

    van Duijvenvoorde, Anna C K; Zanolie, Kiki; Rombouts, Serge A R B; Raijmakers, Maartje E J; Crone, Eveline A

    2008-09-17

    How children learn from positive and negative performance feedback lies at the foundation of successful learning and is therefore of great importance for educational practice. In this study, we used functional magnetic resonance imaging (fMRI) to examine the neural developmental changes related to feedback-based learning when performing a rule search and application task. Behavioral results from three age groups (8-9, 11-13, and 18-25 years of age) demonstrated that, compared with adults, 8- to 9-year-old children performed disproportionally more inaccurately after receiving negative feedback relative to positive feedback. Additionally, imaging data pointed toward a qualitative difference in how children and adults use performance feedback. That is, dorsolateral prefrontal cortex and superior parietal cortex were more active after negative feedback for adults, but after positive feedback for children (8-9 years of age). For 11- to 13-year-olds, these regions did not show differential feedback sensitivity, suggesting that the transition occurs around this age. Pre-supplementary motor area/anterior cingulate cortex, in contrast, was more active after negative feedback in both 11- to 13-year-olds and adults, but not 8- to 9-year-olds. Together, the current data show that cognitive control areas are differentially engaged during feedback-based learning across development. Adults engage these regions after signals of response adjustment (i.e., negative feedback). Young children engage these regions after signals of response continuation (i.e., positive feedback). The neural activation patterns found in 11- to 13-year-olds indicate a transition around this age toward an increased influence of negative feedback on performance adjustment. This is the first developmental fMRI study to compare qualitative changes in brain activation during feedback learning across distinct stages of development.

  13. Positive predictive value and completeness of prenatally assigned International Classification of Disease-10 kidney anomaly diagnoses in the Danish National Patient Registry

    Directory of Open Access Journals (Sweden)

    Rasmussen M

    2016-01-01

    Full Text Available Maria Rasmussen,1 Morten Smærup Olsen,2 Lone Sunde,1,3 Lars Pedersen,2 Olav Bjørn Petersen4 1Department of Clinical Genetics, Aarhus University Hospital, Skejby, 2Department of Clinical Epidemiology, Aarhus University Hospital, Skejby, 3Department of Biomedicine, Aarhus University, Aarhus, 4Department of Gynecology and Obstetrics, Aarhus University Hospital, Skejby, Denmark Objective: Restricting studies of severe congenital malformations to live-born children may introduce substantial bias. In this study, we estimated the attendance to the second-trimester fetal malformation screening program. We also estimated the positive predictive value (PPV of prenatally assigned International Classification of Disease-10 diagnoses recorded in the Danish National Patient Registry (DNPR and the completeness of case registration. We used kidney anomalies as an example. Methods: We identified the proportion of all Danish live-born children from January 1, 2007 to December 31, 2012, who were scanned during the second trimester using the DNPR and the Civil Registration System. Details of all fetuses with specific kidney anomaly diagnoses according to the DNPR were retrieved. The PPV was estimated using the nationwide Astraia database of pregnancy medical charts or traditional medical charts, as gold standard. The completeness was assessed using the total number of cases estimated by the capture–recapture method. Results: Of 372,263 live born infants, 97.3% were scanned during the second trimester. We identified 172 fetuses in the DNPR. Of these, 149 had kidney anomalies according to Astraia or medical chart review, corresponding to a PPV of 87% (95% CI: 81%–91%. The estimated completeness was 43% (95% CI: 38%–49% for the DNPR and 75% (95% CI: 70%–79% for Astraia. Conclusion: Almost all live-born children were scanned during the second trimester in Denmark. However, low completeness may hamper the use of the DNPR for studies of prenatally detected

  14. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma.

    Science.gov (United States)

    Tummers, W; van Schuppen, J; Langeveld, H; Wilde, J; Banderker, E; van As, A

    2016-06-01

    The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical decision-making regarding paediatric BAT. Children presented at the Trauma Unit of the Red Cross War Memorial Children's Hospital, Cape Town, after HET, and underwent both a physical examination and a FAST. The presence of free fluid in the abdomen and pelvis was assessed using a FAST. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) for identifying intraabdominal injury were calculated for the physical examination and the FAST, both individually and when combined. Seventy-five patients were included as per the criteria for HET as follows: pedestrian motor vehicle crashes (MVCs) ( n = 46), assault ( n = 14), fall from a height ( n = 9), MVC passenger ( n = 4) and other ( n = 2). The ages of the patients ranged from 3 months to 13 years. The sensitivity of the physical examination was 0.80, specificity 0.83, PPV 0.42 and NPV 0.96. The sensitivity of the FAST was 0.50, specificity 1.00, PPV 1.00 and NPV 0.93. Sensitivity increased to 0.90 when the physical examination was combined with the FAST. Nonoperative management was used in 73 patients. Two underwent an operation. A FAST should be performed in combination with a physical examination on every paediatric patient involved in HET to detect BAT. When both are negative, nonoperative management can be implemented without fear of missing a clinically significant injury. FAST is a safe, effective and easily accessible alternative to CT, which avoids ionising radiation and aids in clinical decision-making.

  15. Axillary fine needle aspiration cytology for pre-operative staging of patients with screen-detected invasive breast carcinoma.

    LENUS (Irish Health Repository)

    Hayes, Brian D

    2012-02-01

    INTRODUCTION: Fine needle aspiration cytology (FNAC) of radiologically abnormal axillary lymph nodes in patients with breast cancer can identify patients suitable for primary axillary clearance (AC) rather than sentinel node biopsy, enabling surgical axillary staging by a single operation. This study assessed the accuracy of FNAC in predicting positive axillary lymph nodes. METHODS: 161 patients with screen-detected invasive carcinoma and who had pre-operative FNAC of a radiologically abnormal axillary lymph node were identified from two screening units, The axillary FNAC reports were correlated with sentinel node biopsy and AC reports, and sensitivity, specificity, positive (PPV) and negative (NPV) predictive values were calculated. RESULTS: FNAC had a moderate sensitivity (66.3%) and NPV (71.8%), and a high specificity (98.7%) and PPV (98.3%). Most patients (86%) had a single axillary operation. The sensitivity was highest in grade 3 (81.8%) and ductal type (77.8%) tumours. The sensitivity was lower in tumours of special type (34.8%), grade 1 tumours (50%) and those without lymphovascular invasion (LVI) (55.9%). The NPV was highest in pT1 (86.7%) and in grade 1 (84.5%) tumours, and lowest (44%) in tumours with LVI. The PPV was 100% in grade 1 and 3 tumours, stage pT2 and pT3 tumours and those without LVI, and was high (>96%) in all other groups. In lymph-node-positive patients, the mean number of lymph nodes involved was higher in the case of a positive (6.4) than negative FNAC (4.4). CONCLUSIONS: FNAC of ultrasonically abnormal axillary lymph nodes achieved surgical staging by a single operation in most patients with screen-detected invasive breast carcinoma, with moderate sensitivity and high specificity.

  16. Audit of paired anal cytology and histopathology outcomes in patients referred to a public sexual health clinic.

    Science.gov (United States)

    Williams, Vincent M; Metcalf, Cecily; French, Martyn A; McCloskey, Jenny C

    2010-09-01

    The level of agreement between anal cytology and histopathology is not clear with only a few studies evaluating the reliability of anal specimen reporting. Australian data in relation to this are limited. The results of paired anal cytology and histopathology specimens received between 2002 and 2008 from patients who were referred within the sexual health clinic were retrieved from the anatomical pathology database. A total of 248 paired samples from 154 (21 females, 133 males) participants were extracted. Concurrent high risk human papilloma virus (hrHPV) DNA assay and HIV status for the study group were also collected. Data were tabulated according to reported grade of squamous abnormality based on the Bethesda system. Using the biopsy result as the gold standard the specificity, sensitivity, positive predictive value (PPV) and negative predictive value (NPV) for cytology were calculated and the association between grade of abnormality, HIV status and hrHPV infection estimated. Concordance between cytology and histology showed that in 204 (85%) paired samples both tests were categorised as abnormal (Kappa statistic 0.73, P = 0.013). The cytology result showed a sensitivity of 96%, specificity 14%, PPV 89% and NPV 31% when compared with histopathology. HrHPV assay was positive in 192 (80%) samples. High-grade squamous abnormalities were reported in biopsy specimens from 60% (n = 42/67) of HIV-positive subjects and 25% (n = 22/87) of HIV-negative subjects. HIV-positive individuals were more likely to be hrHPV positive, odds ratio (OR) 6.21 [95% confidence interval (CI) 2.69 to 14.34], when compared with HIV-negative subjects. Anal cytology is highly sensitive for the detection of abnormal squamous cells. While cytology has low specificity for predicting the grade of abnormality compared with biopsy outcome, its application as a screening method in asymptomatic at risk populations warrants further study.

  17. Unimode metamaterials exhibiting negative linear compressibility and negative thermal expansion

    International Nuclear Information System (INIS)

    Dudek, Krzysztof K; Attard, Daphne; Caruana-Gauci, Roberto; Grima, Joseph N; Wojciechowski, Krzysztof W

    2016-01-01

    Unimode metamaterials made from rotating rigid triangles are analysed mathematically for their mechanical and thermal expansion properties. It is shown that these unimode systems exhibit positive Poisson’s ratios irrespective of size, shape and angle of aperture, with the Poisson’s ratio exhibiting giant values for certain conformations. When the Poisson’s ratio in one loading direction is larger than +1, the systems were found to exhibit the anomalous property of negative linear compressibility along this direction, that is, the systems expand in this direction when hydrostatically compressed. Also discussed are the thermal expansion properties of these systems under the assumption that the units exhibit increased rotational agitation once subjected to an increase in temperature. The effect of the geometric parameters on the aforementioned thermo-mechanical properties of the system, are discussed, with the aim of identifying negative behaviour. (paper)

  18. Role of Combined Post-Operative Venous Lactate and 48 Hours C-Reactive Protein Values on the Etiology and Predictive Capacity of Organ-Space Surgical Site Infection after Elective Colorectal Operation.

    Science.gov (United States)

    Juvany, Montserrat; Guirao, Xavier; Oliva, Joan Carles; Badía Pérez, Jose M

    2017-04-01

    C-reactive protein (CRP) has been assessed to detect organ-space surgical site infection (OSI). Nevertheless, data about peri-operative oxygen debt and surgical stress-elicited biologic markers to explain and allow for the early detection of OSI are lacking. We analyzed immediate post-operative venous lactate, early CRP levels, and intra-operative hemodynamic values on the capacity to predict OSI after elective colorectal operation. Patients undergoing an elective colorectal surgical procedure with anastomosis between March 2013 and August 2014 were included and assessed prospectively. Post-operative lactate values at L-0, L-6, and L-24 hours, CRP (basal and 48 h), and the percentage of operative time (POT) with systolic blood pressure below 100 mm Hg and heart rate above 90 beats per minute in patients with and without OSI were compared. Binary logistic regression was constructed for L-0 and CRP-48, and receiver-operating characteristic (ROC) was analyzed for sensitivity (S), specificity (Sp), positive (PPV) and negative (NPV) predictive values. Patients with OSI (11 of 100) showed higher L-0 and L-24 (3.2 ± 2.5 vs. 1.6 ± 0.8; p = 0.025 and 1.9 ± 1.2 vs. 1.2 ± 0.4 mmol/L; p = 0.025) and CRP-48 (188 ± 80 vs. 74 ± 52 mg/L; p = 0.001). The ROC from logistic regression showed area under the curve of 0.899 (95% confidence interval [CI] 0.805-0.992), S of 72% (95% CI 43.2%-90.5%), Sp of 95% (95% CI 88.6%-98.4%), PPV of 66% (95% CI 38.9%-86.4%) and NPV of 0.96 (95% CI 90%-99%). L-0 was higher in those patients with hypotension during more than 60% of the POT (2.4 ± 2.1 vs. 1.6 ± 0.8; p = 0.038). Patients with OSI had a higher POT with hypotension (50 ± 28% vs. 30 ± 28%; p = 0.032) and tachycardia (18 ± 27% vs. 5 ± 16%; p = 0,024). The combination of immediate post-operative lactate and CRP at 48 hours proved to be useful in predicting OSI after elective colorectal operation

  19. Valor preditivo dos escores de SNAP e SNAP-PE na mortalidade neonatal Predictive value of SNAP and SNAP-PE for neonatal mortality

    Directory of Open Access Journals (Sweden)

    Rita C. Silveira

    2001-12-01

    results. METHODS: All newborn infants admitted to our neonatal intensive care unit from March 1997 through December 1998 were prospectively evaluated just at completion of 24 hours of life for SNAP and SNAP-PE. Exclusion criteria were: death or discharge from the neonatal intensive care unit in the first 24 hours of life, congenital malformations incompatible with life, and outborn infants. RESULTS: 553 newborn infants were included in the study and 54 died. The median SNAP and SNAP-PE values were higher in those who died. Infants were allocated to five different raising ranges of SNAP and SNAP-PE severity. SNAP: up to 6, 7-11, 12-15, 16-24, higher than 24 (mortality: 3%, 11%, 29%, 48%,75%, respectively. SNAP-PE: up to 11, 12-23, 24-32, 33-50, higher than 50 (mortality: 3%, 10%, 53%, 78%, 83%, respectively. The optimal cut off points based on ROC curve were 12 for SNAP, and 24 for SNAP-PE. Sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV for death were figured out. SNAP 12: sensitivity 79.6%, specificity 71.7%, PPV 23.4%, NPV 97%. SNAP-PE 24: sensitivity 79.6%, specificity 80%, PPV 30%, NPV 97.3%. The area under the curve (Az were 81.4% for SNAP, and 85.1% for SNAP-PE, both statistically significant. There were no statistical differences between the two areas under the curve. CONCLUSIONS: SNAP and SNAP-PE are excellent predictors of neonatal survival. Therefore, we recommend their use in Neonatal Intensive Care Units.

  20. Financial Incentives Differentially Regulate Neural Processing of Positive and Negative Emotions during Value-Based Decision-Making

    Directory of Open Access Journals (Sweden)

    Anne M. Farrell

    2018-02-01

    Full Text Available Emotional and economic incentives often conflict in decision environments. To make economically desirable decisions then, deliberative neural processes must be engaged to regulate automatic emotional reactions. In this functional magnetic resonance imaging (fMRI study, we evaluated how fixed wage (FW incentives and performance-based (PB financial incentives, in which pay is proportional to outcome, differentially regulate positive and negative emotional reactions to hypothetical colleagues that conflicted with the economics of available alternatives. Neural activity from FW to PB incentive contexts decreased for positive emotional stimuli but increased for negative stimuli in middle temporal, insula, and medial prefrontal regions. In addition, PB incentives further induced greater responses to negative than positive emotional decisions in the frontal and anterior cingulate regions involved in emotion regulation. Greater response to positive than negative emotional features in these regions also correlated with lower frequencies of economically desirable choices. Our findings suggest that whereas positive emotion regulation involves a reduction of responses in valence representation regions, negative emotion regulation additionally engages brain regions for deliberative processing and signaling of incongruous events.

  1. Financial Incentives Differentially Regulate Neural Processing of Positive and Negative Emotions during Value-Based Decision-Making.

    Science.gov (United States)

    Farrell, Anne M; Goh, Joshua O S; White, Brian J

    2018-01-01

    Emotional and economic incentives often conflict in decision environments. To make economically desirable decisions then, deliberative neural processes must be engaged to regulate automatic emotional reactions. In this functional magnetic resonance imaging (fMRI) study, we evaluated how fixed wage (FW) incentives and performance-based (PB) financial incentives, in which pay is proportional to outcome, differentially regulate positive and negative emotional reactions to hypothetical colleagues that conflicted with the economics of available alternatives. Neural activity from FW to PB incentive contexts decreased for positive emotional stimuli but increased for negative stimuli in middle temporal, insula, and medial prefrontal regions. In addition, PB incentives further induced greater responses to negative than positive emotional decisions in the frontal and anterior cingulate regions involved in emotion regulation. Greater response to positive than negative emotional features in these regions also correlated with lower frequencies of economically desirable choices. Our findings suggest that whereas positive emotion regulation involves a reduction of responses in valence representation regions, negative emotion regulation additionally engages brain regions for deliberative processing and signaling of incongruous events.

  2. A feature of negative hydrogen ion production in the Uramoto-type sheet plasma

    Energy Technology Data Exchange (ETDEWEB)

    Jimbo, Kouichi [Kyoto Univ., Uji (Japan). Inst. of Atomic Energy

    1997-02-01

    It seems that negative hydrogen ions H{sup -} are formed directly from atomic hydrogens H. When the chamber was biased more negative against the anode potential at constant are power, forming a much deeper electrostatic well in the Uramoto-type sheet plasma negative ion source, more negative hydrogen ion currents were extracted. The chamber potential V{sub B} was biased down to -100V in the 150V discharge. The negative ion current J{sup -} was evaluated by the JAERI-probe measurement. J{sup -} increases linearly with the chamber current I{sub B}. The largest J{sup -} value was obtained at absolute value of |V{sub prob,f}|=15V and absolute value of |V{sub B}|=100V; the discharge was not operated for absolute value of |V{sub B}|>100V. We speculate the following collisional (three-body) electron attachment to H as a possible production process for H{sup -}; e+e+H{yields}e+H{sup -}. This process may explain the linear increase of J{sup -} with absolute value of |V{sub prob,f}|. (S.Y.)

  3. Does individualism bring happiness? Negative effects of individualism on interpersonal relationships and happiness.

    Science.gov (United States)

    Ogihara, Yuji; Uchida, Yukiko

    2014-01-01

    We examined the negative effects of individualism in an East Asian culture. Although individualistic systems decrease interpersonal relationships through competition, individualistic values have prevailed in European American cultures. One reason is because individuals could overcome negativity by actively constructing interpersonal relationships. In contrast, people in East Asian cultures do not have such strategies to overcome the negative impact of individualistic systems, leading to decreased well-being. To test this hypothesis, we investigated the relationship between individualistic values, number of close friends, and subjective well-being (SWB). Study 1 indicated that individualistic values were negatively related with the number of close friends and SWB for Japanese college students but not for American college students. Moreover, Study 2 showed that even in an individualistic workplace in Japan, individualistic values were negatively related with the number of close friends and SWB. We discuss how cultural change toward increasing individualism might affect interpersonal relationships and well-being.

  4. Does individualism bring happiness? Negative effects of individualism on interpersonal relationships and happiness

    Directory of Open Access Journals (Sweden)

    Yuji eOgihara

    2014-03-01

    Full Text Available We examined the negative effects of individualism in an East Asian culture. Although individualistic systems decrease interpersonal relationships through competition, individualistic values have prevailed in European American cultures. One reason is because individuals could overcome negativity by actively constructing interpersonal relationships. In contrast, people in East Asian cultures do not have such strategies to overcome the negative impact of individualistic systems, leading to decreased well-being. To test this hypothesis, we investigated the relationship between individualistic values, number of close friends, and subjective well-being (SWB. Study 1 indicated that individualistic values were negatively related with the number of close friends and SWB for Japanese college students but not for American college students. Moreover, Study 2 showed that even in an individualistic workplace in Japan, individualistic values were negatively related with the number of close friends and SWB. We discuss how cultural change toward increasing individualism might affect interpersonal relationships and well-being.

  5. Value of 3.0 T MR imaging in refractory partial epilepsy and negative 1.5 T MRI.

    Science.gov (United States)

    Nguyen, Dang Khoa; Rochette, Emilie; Leroux, Jean-Maxime; Beaudoin, Gilles; Cossette, Patrick; Lassonde, Maryse; Guilbert, François

    2010-10-01

    High-field 3.0 T MR scanners provide an improved signal-to-noise ratio which can be translated in higher image resolution, possibly allowing critical detection of subtle epileptogenic lesions missed on standard-field 1.0-1.5 T MRIs. In this study, the authors explore the potential value of re-imaging at 3.0 T patients with refractory partial epilepsy and negative 1.5 T MRI. We retrospectively identified all patients with refractory partial epilepsy candidate for surgery who had undergone a 3.0 T MR study after a negative 1.5 T MR study. High-field 3.0 T MRIs were reviewed qualitatively by neuroradiologists experienced in interpreting epilepsy studies with access to clinical information. Relevance and impact on clinical management were assessed by an epileptologist. Between November 2006 and August 2009, 36 patients with refractory partial epilepsy candidate for surgery underwent 3.0 T MR study after a 1.5 T MR study failed to disclose a relevant epileptogenic lesion. A potential lesion was found only in two patients (5.6%, 95% CI: 1.5-18.1%). Both were found to have hippocampal atrophy congruent with other presurgical localization techniques which resulted in omission of an invasive EEG study and direct passage to surgery. The frequency of detection of a new lesion by re-imaging at 3.0 T patients with refractory partial epilepsy candidate for surgery was found to be low, but seems to offer the potential of a significant clinical impact for selected patients. This finding needs to be validated in a prospective controlled study. Copyright © 2010 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  6. Accuracy of preoperative CT T staging of renal cell carcinoma: which features predict advanced stage?

    International Nuclear Information System (INIS)

    Bradley, A.J.; MacDonald, L.; Whiteside, S.; Johnson, R.J.; Ramani, V.A.C.

    2015-01-01

    Aims: To characterise CT findings in renal cell carcinoma (RCC), and establish which features are associated with higher clinical T stage disease, and to evaluate patterns of discrepancy between radiological and pathological staging of RCC. Materials and methods: Preoperative CT studies of 92 patients with 94 pathologically proven RCCs were retrospectively reviewed. CT stage was compared with pathological stage using the American Joint Committee on Cancer (AJCC), 7 th edition (2010). The presence or absence of tumour necrosis, perinephric fat standing, thickening of Gerota's fascia, collateral vessels were noted, and correlated with pT stage. The sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) for predicting pT stage ≥pT3a were derived separately for different predictors using cross-tabulations. Results: Twenty-four lesions were pathological stage T1a, 21 were T1b, seven were T2a, 25 were T3a, 11 were T3b, four were T3c, and two were T4. There were no stage T2b. Sixty-three (67%) patients had necrosis, 27 (29%) thickening of Gerota's fascia (1 T1a), 25 had collateral vessels (0 T1a), 28 (30%) had fat stranding of <2 mm, 20 (21%) of 2–5mm and one (1%) of >5 mm. For pT stage ≥pT3a, the presence of perinephric fat stranding had a sensitivity, specificity, PPV and NPV of 74%, 65%, 63%, and 76%, respectively. Presence of tumour necrosis had a sensitivity, specificity, PPV, and NPV of 81%, 44%, 54%, and 72%, respectively. Thickening of Gerota's fascia had a sensitivity, specificity, PPV, and NPV of 52%, 90%, 81% and 70%, respectively; and enlarged collateral vessels had a sensitivity, specificity, PPV, and NPV value of 52%, 94%, 88%, and 71% respectively. Conclusion: The presence of perinephric stranding and tumour necrosis were not reliable signs for pT stage >T3a. Thickening of Gerota's fascia and the presence of collateral vessels in the peri- or paranephric fat had 90% and 94% specificity, with 82% and 88

  7. Malignancy Risk Assessment in Patients with Thyroid Nodules Using Classification and Regression Trees

    Directory of Open Access Journals (Sweden)

    Shokouh Taghipour Zahir

    2013-01-01

    Full Text Available Purpose. We sought to investigate the utility of classification and regression trees (CART classifier to differentiate benign from malignant nodules in patients referred for thyroid surgery. Methods. Clinical and demographic data of 271 patients referred to the Sadoughi Hospital during 2006–2011 were collected. In a two-step approach, a CART classifier was employed to differentiate patients with a high versus low risk of thyroid malignancy. The first step served as the screening procedure and was tailored to produce as few false negatives as possible. The second step identified those with the lowest risk of malignancy, chosen from a high risk population. Sensitivity, specificity, positive and negative predictive values (PPV and NPV of the optimal tree were calculated. Results. In the first step, age, sex, and nodule size contributed to the optimal tree. Ultrasonographic features were employed in the second step with hypoechogenicity and/or microcalcifications yielding the highest discriminatory ability. The combined tree produced a sensitivity and specificity of 80.0% (95% CI: 29.9–98.9 and 94.1% (95% CI: 78.9–99.0, respectively. NPV and PPV were 66.7% (41.1–85.6 and 97.0% (82.5–99.8, respectively. Conclusion. CART classifier reliably identifies patients with a low risk of malignancy who can avoid unnecessary surgery.

  8. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  9. Moderate sensitivity and high specificity of emergency department administrative data for transient ischemic attacks.

    Science.gov (United States)

    Yu, Amy Y X; Quan, Hude; McRae, Andrew; Wagner, Gabrielle O; Hill, Michael D; Coutts, Shelagh B

    2017-09-18

    Validation of administrative data case definitions is key for accurate passive surveillance of disease. Transient ischemic attack (TIA) is a condition primarily managed in the emergency department. However, prior validation studies have focused on data after inpatient hospitalization. We aimed to determine the validity of the Canadian 10th International Classification of Diseases (ICD-10-CA) codes for TIA in the national ambulatory administrative database. We performed a diagnostic accuracy study of four ICD-10-CA case definition algorithms for TIA in the emergency department setting. The study population was obtained from two ongoing studies on the diagnosis of TIA and minor stroke versus stroke mimic using serum biomarkers and neuroimaging. Two reference standards were used 1) the emergency department clinical diagnosis determined by chart abstractors and 2) the 90-day final diagnosis, both obtained by stroke neurologists, to calculate the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the ICD-10-CA algorithms for TIA. Among 417 patients, emergency department adjudication showed 163 (39.1%) TIA, 155 (37.2%) ischemic strokes, and 99 (23.7%) stroke mimics. The most restrictive algorithm, defined as a TIA code in the main position had the lowest sensitivity (36.8%), but highest specificity (92.5%) and PPV (76.0%). The most inclusive algorithm, defined as a TIA code in any position with and without query prefix had the highest sensitivity (63.8%), but lowest specificity (81.5%) and PPV (68.9%). Sensitivity, specificity, PPV, and NPV were overall lower when using the 90-day diagnosis as reference standard. Emergency department administrative data reflect diagnosis of suspected TIA with high specificity, but underestimate the burden of disease. Future studies are necessary to understand the reasons for the low to moderate sensitivity.

  10. Validation of a norovirus multiplex real-time RT-PCR assay for the detection of norovirus GI and GII from faeces samples.

    LENUS (Irish Health Repository)

    Jones, S

    2011-01-01

    Norovirus is a leading cause of infectious non-bacterial gastroenteritis. The virus is highly contagious and has multiple modes of transmission, presenting a growing challenge to hospital-based healthcare. In this study, a total of 120 stool samples are tested for the presence of norovirus GI and GII by the Roche two-step Lightcycler 2.0 assay incorporating primers and probes produced by TIB Molbiol, and the results are compared with results from the National Virus Reference Laboratory. The Roche\\/TIB Molbiol assay produced 51 positive results and 69 negative results. Discrepancy analysis was performed for six conflicting results using a second real-time polymerase chain reaction (PCR) assay (Roche\\/TIB Molbiol) and this confirmed that four of the five discrepant positive results were true positives. A single discrepant negative result generated by the Roche assay remained negative using the second assay. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated to be 98%, 98.6%, 98.0% and 98.6%, respectively. Melting curve analysis was used to differentiate genogroups I and II and this showed that 92% of strains belonged to genogroup II.

  11. Limitations of 64-Detector-Row Computed Tomography Coronary Angiography: Calcium and Motion but not Short Experience

    International Nuclear Information System (INIS)

    Mir-Akbari, H.; Ripsweden, J.; Jensen, J.; Pichler, P.; Sylven, C.; Cederlund, K.; Rueck, A.

    2009-01-01

    Background: Recently, 64-detector-row computed tomography coronary angiography (CTA) has been introduced for the noninvasive diagnosis of coronary artery disease. Purpose: To evaluate the diagnostic capacity and limitations of a newly established CTA service. Material and Methods: In 101 outpatients with suspected coronary artery disease, 64-detector-row CTA (VCT Lightspeed 64; GE Healthcare, Milwaukee, WI., USA) was performed before invasive coronary angiography (ICA). The presence of >50% diameter coronary stenosis on CTA was rated by two radiologists recently trained in CTA, and separately by an experienced colleague. Diagnostic performance of CTA was calculated on segment, vessel, and patient levels, using ICA as a reference. Segments with a proximal reference diameter <2 mm or with stents were not analyzed. Results: In 51 of 101 patients and 121 of 1280 segments, ICA detected coronary stenosis. In 274 of 1280 (21%) segments, CTA had non-diagnostic image quality, the main reasons being severe calcifications (49%), motion artifacts associated with high or irregular heart rate (45%), and low contrast opacification (14%). Significantly more women (43%) had non-diagnostic scans compared to men (20%). A heart rate above 60 beats per minute was associated with significantly more non-diagnostic patients (38% vs. 18%). In the 1006 diagnostic segments, CTA had a sensitivity of 78%, specificity of 95%, positive predictive value (PPV) of 54%, and negative predictive value (NPV) of 98% for detecting significant coronary stenosis. In 29 patients, CTA was non-diagnostic. In the remaining 72 patients, sensitivity was 100%, specificity 65%, PPV 79%, and NPV 100%. The use of a more experienced CTA reader did not improve diagnostic performance. Conclusion: CTA had a very high negative predictive value, but the number of non-diagnostic scans was high, especially in women. The main limitations were motion artifacts and vessel calcifications, while short experience in CTA did not

  12. Lymph node metastases from head and neck squamous cell carcinoma: MR imaging with ultrasmall superparamagnetic iron oxide particles (Sinerem MR) - results of a phase-III multicenter clinical trial

    International Nuclear Information System (INIS)

    Sigal, R.; Viala, J.; Bosq, J.; Vogl, T.; Mack, M.; Casselman, J.; Depondt, M.; Mattelaer, C.; Moulin, G.; Petit, P.; Champsaur, P.; Veillon, F.; Riehm, S.; Dadashitazehozi, Y.; Hermans, R.; de Jaegere, T.; Marchal, G.; Dubrulle, F.; Chevalier, D.; Lemaitre, L.; Kubiak, C.; Helmberger, R.; Halimi, P.

    2002-01-01

    The aim of this study was to compare the clinical usefulness of ultrasmall superparamagnetic iron oxide (USPIO) MR contrast media (Sinerem, Guerbet Laboratories, Aulnay-sous-Bois, France) with precontrast MRI in the diagnosis of metastatic lymph nodes in patients with head and neck squamous cell carcinoma, using histology as gold standard. Eighty-one previously untreated patients were enrolled in a multicenter phase-III clinical trial. All patients had a noncontrast MR, a Sinerem MR, and surgery within a period of 15 days. The MR exams were analyzed both on site and by two independent radiologists (centralized readers). Correlation between histology and imaging was done per lymph node groups, and per individual lymph nodes when the short axis was ≥10 mm. For individual lymph nodes, Sinerem MR showed a high sensitivity (≥88%) and specificity (≥77%). For lymph node groups, the sensitivity was ≥59% and specificity ≥81%. False-positive results were partially due to inflammatory nodes; false-negative results from the presence of undetected micrometastases. Errors of interpretation were also related to motion and/or susceptibility artifacts and problems of zone assignment. Sinerem MR had a negative predictive value (NPV) ≥90% and a positive predictive value (PPV) ≥51%. The specificity and PPV of Sinerem MR were better than those of precontrast MR. Precontrast MR showed an unexpectedly high sensitivity and NPV which were not increased with Sinerem MR. The potential contribution of Sinerem MR still remains limited by technical problems regarding motion and susceptibility artifacts and spatial resolution. It is also noteworthy that logistical problems, which could reduce the practical value of Sinerem MR, will be minimized in the future since Sinerem MR alone performed as good as the combination of precontrast and Sinerem MR. (orig.)

  13. Lymph node metastases from head and neck squamous cell carcinoma: MR imaging with ultrasmall superparamagnetic iron oxide particles (Sinerem MR) - results of a phase-III multicenter clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Sigal, R.; Viala, J.; Bosq, J. [Department of Radiology, Institut Gustave Roussy, Villejuif (France); Vogl, T.; Mack, M. [Institut fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum, Frankfurt Main (Germany); Casselman, J.; Depondt, M.; Mattelaer, C. [Department of Radiology, Brugge (Belgium); Moulin, G.; Petit, P.; Champsaur, P. [Hopital de la Timone, Marseille (France); Veillon, F.; Riehm, S.; Dadashitazehozi, Y. [Hopital de Hautepierre, Avenue Moliere, 67098 Strasbourg (France); Hermans, R.; de Jaegere, T.; Marchal, G. [Department of Radiology, University Hospitals Gasthuisberg, KU Leuven, Heerestraat 49, 3000 Leuven (Belgium); Dubrulle, F.; Chevalier, D.; Lemaitre, L. [Hopital Huriez, 1 place Verdun, 59037 Lille (France); Kubiak, C.; Helmberger, R.; Halimi, P.

    2002-05-01

    The aim of this study was to compare the clinical usefulness of ultrasmall superparamagnetic iron oxide (USPIO) MR contrast media (Sinerem, Guerbet Laboratories, Aulnay-sous-Bois, France) with precontrast MRI in the diagnosis of metastatic lymph nodes in patients with head and neck squamous cell carcinoma, using histology as gold standard. Eighty-one previously untreated patients were enrolled in a multicenter phase-III clinical trial. All patients had a noncontrast MR, a Sinerem MR, and surgery within a period of 15 days. The MR exams were analyzed both on site and by two independent radiologists (centralized readers). Correlation between histology and imaging was done per lymph node groups, and per individual lymph nodes when the short axis was {>=}10 mm. For individual lymph nodes, Sinerem MR showed a high sensitivity ({>=}88%) and specificity ({>=}77%). For lymph node groups, the sensitivity was {>=}59% and specificity {>=}81%. False-positive results were partially due to inflammatory nodes; false-negative results from the presence of undetected micrometastases. Errors of interpretation were also related to motion and/or susceptibility artifacts and problems of zone assignment. Sinerem MR had a negative predictive value (NPV) {>=}90% and a positive predictive value (PPV) {>=}51%. The specificity and PPV of Sinerem MR were better than those of precontrast MR. Precontrast MR showed an unexpectedly high sensitivity and NPV which were not increased with Sinerem MR. The potential contribution of Sinerem MR still remains limited by technical problems regarding motion and susceptibility artifacts and spatial resolution. It is also noteworthy that logistical problems, which could reduce the practical value of Sinerem MR, will be minimized in the future since Sinerem MR alone performed as good as the combination of precontrast and Sinerem MR. (orig.)

  14. Does blood pressure change in treated hypertensive patients depending on whether it is measured by a physician or a nurse?

    Science.gov (United States)

    Coll De Tuero, Gabriel; Sanmartin Albertos, Maria; Vargas Vila, Susanna; Trèmols Iglesias, Susanna; Saez Zafra, Marc; Barceló Rado, Antonia

    2004-01-01

    To determine whether there are differences between blood pressure (BP) measured by the nurse (NBP), BP measured by the physician (PBP) and self-measured BP in treated hypertensive patients and, if found, to evaluate their clinical importance. An observational study is carried out with hypertensive patients recruited from two village-based community health centres in Catalonia (Spain) serving an area with a total population of 2800 inhabitants. All patients treated for hypertension visiting the health centre on a specific day of the week and during the same timetable between October 2000 and May 2001 were included. The difference between physician-systolic BP and nurse-systolic BP was 5.16 mmHg (95% CI 2.62-7.7; pself-measured systolic BP was 4.67 mmHg (95% CI 0.89-8.44; p=0.016). The differences between nurse-systolic BP and self-measured systolic BP were not significant (0.49 mmHg; 95% CI 3.71-2.71; p=0.758). With regards to diastolic BP, no significant differences were found between the different ways of measurement. NBP gave the following values: sensitivity (Sn) of 92% and specificity (Sp) of 60%; positive predictive value (PPV) of 65.7% and negative predictive value (NPV) of 90% with a positive coefficient of probability (CP+) of 2.3 and a negative coefficient of probability (CP-) of 0.133. PBP gave the following results: Sn=72%; Sp=66.7%; PPV=64.3%; NPV=74.1%; CP+=2.16 and CP- = 0.420. Systolic BP measured by the nurse in treated hypertensive patients is significantly lower than the readings obtained by the physician, and are almost identical to ambulatory BP monitoring. Blood pressure determination by the nurse is desirable not only for diagnosis but also to evaluate the level of control of blood pressure during the follow-up of treated hypertensive patients.

  15. Identifying clinically meaningful symptom response cut-off values on the SANS in predominant negative symptoms.

    Science.gov (United States)

    Levine, Stephen Z; Leucht, Stefan

    2013-04-01

    The treatment and measurement of negative symptoms are currently at issue in schizophrenia, but the clinical meaning of symptom severity and change is unclear. To offer a clinically meaningful interpretation of severity and change scores on the Scale for the Assessment of Negative Symptoms (SANS). Patients were intention-to-treat participants (n=383) in two double-blind randomized placebo-controlled clinical trials that compared amisulpride with placebo for the treatment of predominant negative symptoms. Equipercentile linking was used to examine extrapolation from (a) CGI-S to SANS severity ratings, and (b) CGI-I to SANS percentage change (n=383). Linking was conducted at baseline, 8-14 days, 28-30 days, and 56-60 days of the trials. Across visits, CGI-S ratings of 'not ill' linked to SANS scores of 0-13, and ranged to 'extreme' ratings that linked to SANS scores of 102-105. The relationship between the CGI-S and the SANS severity scores assumed a linear trend (1=0-13, 2=15-56, 3=37-61, 4=49-66, 5=63-75, 6=79-89, 7=102-105). Similarly the relationship between CGI-I ratings and SANS percentage change followed a linear trend. For instance, CGI-I ratings of 'very much improved' were linked to SANS percent changes of -90 to -67, 'much improved' to -50 to -42, and 'minimally improved' to -21 to -13. The current results uniquely contribute to the debate surrounding negative symptoms by providing clinical meaning to SANS severity and change scores and so offer direction regarding clinically meaningful response cut-off scores to guide treatment targets of predominant negative symptoms. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Role of PCR method using IS6110 primer in detecting Mycobacterium tuberculosis among the clinically diagnosed childhood tuberculosis patients at an urban hospital in Dhaka, Bangladesh.

    Science.gov (United States)

    Kabir, Senjuti; Uddin, Mohammad Khaja Mafij; Chisti, Mohammod Jobayer; Fannana, Tilka; Haque, Mohammad Enamul; Uddin, Muhammad Reaj; Banu, Sayera; Ahmed, Tahmeed

    2018-03-01

    Better methods are needed for the accurate detection of child tuberculosis (TB). This study compared different laboratory tests and evaluated IS6110 PCR for the detection of Mycobacterium tuberculosis (MTB) among clinically diagnosed child TB patients. A total of 102 paediatric patients (PCR testing. The sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of smear microscopy and PCR were compared to the two culture methods. Three patients were positive on smear microscopy (2.9%). MTB was detected by conventional culture in 15.7% (16/102), liquid culture in 14% (14/100), and IS6110 PCR in 61.8% (63/102). PCR detected an additional 45 patients who were undetected with the three other tests. Compared to conventional and liquid culture, respectively, smear microscopy showed sensitivity of 18.8% and 21.4%, specificity of 100% individually, PPV of 100% individually, and NPV of 86.9% and 88.7%, whereas PCR had sensitivity of 87.5% and 92.9%, specificity of 43% individually, PPV of 22.2% and 21%, and NPV of 94.9% and 97.4%. PCR can be useful compared to smear microscopy and culture methods and is applicable as a rapid screening test for child TB. A larger scale study is required to determine its diagnostic efficacy in improving the detection of child TB in the presence and absence of severe malnutrition. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. New intrarenal echo-Doppler velocimetric indices for the diagnosis of renal artery stenosis.

    Science.gov (United States)

    Bardelli, M; Veglio, F; Arosio, E; Cataliotti, A; Valvo, E; Morganti, A

    2006-02-01

    We aimed at comparing the positive and negative predictive values (PPV, NPV) of several intrarenal velocimetric indices for revealing the presence of renal artery stenosis (RAS) among hypertensive patients who underwent a renal angiography for the clinical suspicion of renovascular hypertension. In 106 patients (200 kidneys), the pulsatility index (PI) and resistive index (RI), the acceleration time (AT), and the mean systolic acceleration (ACC(sys)) were evaluated. In addition, the maximal systolic acceleration (ACC(max)), that is, the maximal slope of the acceleration phase, and the maximal acceleration index (AI(max)), that is, the ratio between ACC(max) and the relative peak systolic velocity, were calculated. On angiography, we found that 56 (28%) of the 200 arteries had a greater than 60% RAS. PI and RI had an NPV below 75%, whereas AT, ACC(sys), ACC(max), and AI(max) had an NPV always above 95%. However, ACC(max), and AI(max), at their best cutoff limits, had higher PPV than ACC(sys) and AT (60 and 70% vs 45 and 51%, respectively). Thus, in a cohort of patients with a high prevalence of RAS, PI and RI failed to reach an NPV adequate for a screening test. In contrast, all the acceleration indices we tested had a sufficiently high NPV but AI(max) appears superior to the others because of higher PPV. We propose the evaluation of AI(max) as an additional screening test in patients with hypertension and the clinical suspicion of RAS.

  18. Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer

    International Nuclear Information System (INIS)

    Lefere, Philippe; Silva, Celso; Gryspeerdt, Stefaan; Rodrigues, António; Vasconcelos, Rita; Teixeira, Ricardo; Gouveia, Francisco Henriques de

    2013-01-01

    Purpose: To prospectively assess the performance of teleradiology-based CT colonography to screen a population group of an island, at average risk for colorectal cancer. Materials and methods: A cohort of 514 patients living in Madeira, Portugal, was enrolled in the study. Institutional review board approval was obtained and all patients signed an informed consent. All patients underwent both CT colonography and optical colonoscopy. CT colonography was interpreted by an experienced radiologist at a remote centre using tele-radiology. Per-patient sensitivity, specificity, positive (PPV) and negative (NPV) predictive values with 95% confidence intervals (95%CI) were calculated for colorectal adenomas and advanced neoplasia ≥6 mm. Results: 510 patients were included in the study. CT colonography obtained a per-patient sensitivity, specificity, PPV and, NPV for adenomas ≥6 mm of 98.11% (88.6–99.9% 95% CI), 90.97% (87.8–93.4% 95% CI), 56.52% (45.8–66.7% 95% CI), 99.75% (98.4–99.9% 95% CI). For advanced neoplasia ≥6 mm per-patient sensitivity, specificity, PPV and, NPV were 100% (86.7–100% 95% CI), 87.07% (83.6–89.9% 95% CI), 34.78% (25.3–45.5% 95% CI) and 100% (98.8–100% 95% CI), respectively. Conclusion: In this prospective trial, teleradiology-based CT colonography was accurate to screen a patient cohort of a remote island, at average risk for colorectal cancer

  19. Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lefere, Philippe, E-mail: radiologie@skynet.be [VCTC, Virtual Colonoscopy Teaching Centre, Akkerstraat 32c, B-8830 Hooglede (Belgium); Silva, Celso, E-mail: caras@uma.pt [Human Anatomy of Medical Course, University of Madeira, Praça do Município, 9000-082 Funchal (Portugal); Gryspeerdt, Stefaan, E-mail: stefaan@sgryspeerdt.be [VCTC, Virtual Colonoscopy Teaching Centre, Akkerstraat 32c, B-8830 Hooglede (Belgium); Rodrigues, António, E-mail: nucleo@nid.pt [Nucleo Imagem Diagnostica, Rua 5 De Outubro, 9000-216 Funchal (Portugal); Vasconcelos, Rita, E-mail: rita@uma.pt [Department of Engineering and Mathematics, University of Madeira, Praça do Município, 9000-082 Funchal (Portugal); Teixeira, Ricardo, E-mail: j.teixeira1947@gmail.com [Department of Gastroenterology, Central Hospital of Funchal, Avenida Luís de Camões, 9004513 Funchal (Portugal); Gouveia, Francisco Henriques de, E-mail: fhgouveia@netmadeira.com [LANA, Pathology Centre, Rua João Gago, 10, 9000-071 Funchal (Portugal)

    2013-06-15

    Purpose: To prospectively assess the performance of teleradiology-based CT colonography to screen a population group of an island, at average risk for colorectal cancer. Materials and methods: A cohort of 514 patients living in Madeira, Portugal, was enrolled in the study. Institutional review board approval was obtained and all patients signed an informed consent. All patients underwent both CT colonography and optical colonoscopy. CT colonography was interpreted by an experienced radiologist at a remote centre using tele-radiology. Per-patient sensitivity, specificity, positive (PPV) and negative (NPV) predictive values with 95% confidence intervals (95%CI) were calculated for colorectal adenomas and advanced neoplasia ≥6 mm. Results: 510 patients were included in the study. CT colonography obtained a per-patient sensitivity, specificity, PPV and, NPV for adenomas ≥6 mm of 98.11% (88.6–99.9% 95% CI), 90.97% (87.8–93.4% 95% CI), 56.52% (45.8–66.7% 95% CI), 99.75% (98.4–99.9% 95% CI). For advanced neoplasia ≥6 mm per-patient sensitivity, specificity, PPV and, NPV were 100% (86.7–100% 95% CI), 87.07% (83.6–89.9% 95% CI), 34.78% (25.3–45.5% 95% CI) and 100% (98.8–100% 95% CI), respectively. Conclusion: In this prospective trial, teleradiology-based CT colonography was accurate to screen a patient cohort of a remote island, at average risk for colorectal cancer.

  20. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    Science.gov (United States)

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  1. When negation is not negation

    OpenAIRE

    Milicevic, Nataša

    2008-01-01

    In this paper I will discuss the formation of different types of yes/no questions in Serbian (examples in (1)), focusing on the syntactically and semantically puzzling example (1d), which involves the negative auxiliary inversion. Although there is a negative marker on the fronted auxiliary, the construction does not involve sentential negation. This coincides with the fact that the negative quantifying NPIs cannot be licensed. The question formation and sentential negation have similar synta...

  2. Ultrasound for Appendicitis: Performance and Integration with Clinical Parameters

    Science.gov (United States)

    Löfvenberg, Fanny

    2016-01-01

    Objective. To evaluate the performance of ultrasound in pediatric appendicitis and the integration of US with the pediatric appendicitis score (PAS) and C-reactive protein (CRP). Method. An institution-based, retrospective study of children who underwent abdominal US for suspected appendicitis between 2012 and 2015 at a tertiary pediatric surgery center. US results were dichotomized, with a nonvisualized appendix considered as a negative examination. Results. In total, 438 children were included (mean 8.5 years, 54% boys), with an appendicitis rate of 29%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for US were 82%, 97%, 92%, and 93%, respectively, without significant age or gender differences. Pediatric radiologists had significantly higher sensitivity compared to general radiologists, 88% and 71%, respectively (p appendicitis, regardless of age or gender, and should be the first choice of imaging modalities. Combining US with PAS and CRP may reduce several unnecessary admissions for in-hospital observation. PMID:28044133

  3. Kinetic effects in the propagation of ion-acoustic negative solitons in plasmas with negative ions

    International Nuclear Information System (INIS)

    Roberto, M.

    1986-12-01

    The existence of ion-acoustic negative (rarefactive) solitons in plasmas was experimentally verified and explained by means of the Korteweg-de Vries equation, obtained from a fluid model. The experimental results obtained in a double-plasma machine of the Institute for Space Research, however, have provided values of Mach number larger than predicted by this simple model. In order to improve the analysis of the phenomenon, Kinetic effects resultant from the occurrence of reflected electrons and trapped ions in the soliton potential were considered, using the theory of Sagdeev potential. For the description of the negative ion dynamics the fluid model treatment was preserved. It was verified that the effects of the finite temperature and trapping of the positive ions modify the results predicted by the simple KdV model in such a way that the Mach number is reduced as the ion temperature increases. It was shown that reflection of electrons is consistent with the large experimental values of Mach number. (Author) [pt

  4. Long-term results of pars plana vitrectomy as an anti-inflammatory therapy of pediatric intermediate uveitis resistant to standard medical treatment.

    Science.gov (United States)

    Darsová, Denisa; Pochop, Pavel; Štěpánková, Jana; Dotřelová, Dagmar

    2018-01-01

    To evaluate the efficacy of pars plana vitrectomy (PPV) as an anti-inflammatory therapy in pediatric recurrent intermediate uveitis. A retrospective study evaluated the long-term results of PPV indicated for intermediate uveitis with a mean observation period of 10.3 years (range 7-15.6 years) in 6 children (mean age 8 years, range 6-12 years). Pars plana vitrectomy was performed on 10 eyes in the standard manner and was initiated by vitreous sampling for laboratory examination. Data recorded were perioperative or postoperative vitrectomy complications, anatomic and functional results of PPV, and preoperative and postoperative best-corrected Snellen visual acuity. No perioperative or postoperative complications were observed. Bacteriologic, virologic, mycotic, and cytologic analysis of the vitreous was negative in all tested children. Five eyes were subsequently operated on for posterior subcapsular cataracts. An average preoperative visual acuity of 0.32 improved to an average postoperative visual acuity of 0.8. In the case of systemic immunosuppressive treatment failure in pediatric uveitis, particularly in eyes with cystoid macular edema, we recommend PPV relatively early.

  5. Positive predictive values of the International Classification of Disease, 10th edition diagnoses codes for diverticular disease in the Danish National Registry of Patients

    Directory of Open Access Journals (Sweden)

    Rune Erichsen

    2010-10-01

    Full Text Available Rune Erichsen1, Lisa Strate2, Henrik Toft Sørensen1, John A Baron31Department of Clinical Epidemiology, Aarhus University Hospital, Denmark; 2Division of Gastroenterology, University of Washington, Seattle, WA, USA; 3Departments of Medicine and of Community and Family Medicine, Dartmouth Medical School, NH, USAObjective: To investigate the accuracy of diagnostic coding for diverticular disease in the Danish National Registry of Patients (NRP.Study design and setting: At Aalborg Hospital, Denmark, with a catchment area of 640,000 inhabitants, we identified 100 patients recorded in the NRP with a diagnosis of diverticular disease (International Classification of Disease codes, 10th revision [ICD-10] K572–K579 during the 1999–2008 period. We assessed the positive predictive value (PPV as a measure of the accuracy of discharge codes for diverticular disease using information from discharge abstracts and outpatient notes as the reference standard.Results: Of the 100 patients coded with diverticular disease, 49 had complicated diverticular disease, whereas 51 had uncomplicated diverticulosis. For the overall diagnosis of diverticular disease (K57, the PPV was 0.98 (95% confidence intervals [CIs]: 0.93, 0.99. For the more detailed subgroups of diagnosis indicating the presence or absence of complications (K573–K579 the PPVs ranged from 0.67 (95% CI: 0.09, 0.99 to 0.92 (95% CI: 0.52, 1.00. The diagnosis codes did not allow accurate identification of uncomplicated disease or any specific complication. However, the combined ICD-10 codes K572, K574, and K578 had a PPV of 0.91 (95% CI: 0.71, 0.99 for any complication.Conclusion: The diagnosis codes in the NRP can be used to identify patients with diverticular disease in general; however, they do not accurately discern patients with uncomplicated diverticulosis or with specific diverticular complications.Keywords: diverticulum, colon, diverticulitis, validation studies

  6. Role of Combining Peripheral with Sublingual Perfusion on Evaluating Microcirculation and Predicting Prognosis in Patients with Septic Shock.

    Science.gov (United States)

    Pan, Pan; Liu, Da-Wei; Su, Long-Xiang; He, Huai-Wu; Wang, Xiao-Ting; Yu, Chao

    2018-05-20

    Measurement of general microcirculation remains difficult in septic shock patients. The peripheral perfusion index (PI) and sublingual microcirculation monitoring are thought to be possible methods. This study was performed to determine whether assessing microcirculation by PI and a new parameter, proportion of perfusion vessel change rate (△PPV) from sublingual microcirculation monitoring, can be associated with patients' outcome. A prospective observational study was carried out, including 74 patients with septic shock in a mixed intensive care unit. Systemic hemodynamic variables were obtained at T0 and 6 h after (T6). PI and sublingual microcirculation indicators were obtained using a bedside monitor and a sidestream dark-field device, respectively. The t-test, analysis of variance, Mann-Whitney U-test, Kruskal-Wallis test, receiver operating characteristic curve analysis with the Hanley-McNeil test, survival curves using the Kaplan-Meier method, and the log-rank (Mantel-Cox) test were used to statistical analysis. Systemic hemodynamics and microcirculation data were obtained and analyzed. Patients were divided into two groups based on whether the first 6 h lactate clearance (LC) was ≥20%; PI and △PPV were lower at T6 in the LC <20% group compared with LC ≥20% (PI: 1.52 [0.89, 1.98] vs. 0.79 [0.44, 1,81], Z = -2.514, P = 0.012; △PPV: 5.9 ± 15.2 vs. 17.9 ± 20.0, t = -2.914, P = 0.005). The cutoff values of PI and △PPV were 1.41% and 12.1%, respectively. The cutoff value of the combined indicators was 1.379 according to logistic regression. Area under the curve demonstrated 0.709 (P < 0.05), and the sensitivity and specificity of using combined indicators were 0.622 and 0.757, respectively. Based on the PI and △PPV cutoff, all the participants were divided into the following groups: (1) high PI and high △PPV group, (2) high PI and low △PPV group, (3) low PI and high △PPV group, and (4) low PI and low △PPV group. The highest Sequential

  7. p16/Ki-67 Dual Stain Cytology for Detection of Cervical Precancer in HPV-Positive Women.

    Science.gov (United States)

    Wentzensen, Nicolas; Fetterman, Barbara; Castle, Philip E; Schiffman, Mark; Wood, Shannon N; Stiemerling, Eric; Tokugawa, Diane; Bodelon, Clara; Poitras, Nancy; Lorey, Thomas; Kinney, Walter

    2015-12-01

    Human papillomavirus (HPV)-based cervical cancer screening requires triage markers to decide who should be referred to colposcopy. p16/Ki-67 dual stain cytology has been proposed as a biomarker for cervical precancers. We evaluated the dual stain in a large population of HPV-positive women. One thousand five hundred and nine HPV-positive women screened with HPV/cytology cotesting at Kaiser Permanente California were enrolled into a prospective observational study in 2012. Dual stain cytology was performed on residual Surepath material, and slides were evaluated for dual stain-positive cells. Disease endpoints were ascertained from the clinical database at KPNC. We evaluated the clinical performance of the assay among all HPV-positive women and among HPV-positive, cytology-negative women. We used internal benchmarks for clinical management to evaluate the clinical relevance of the dual stain assay. We evaluated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the dual stain compared with Pap cytology. All statistical tests were two-sided. The dual stain had lower positivity (45.9%) compared with cytology at an ASC-US threshold (53.4%). For detection of CIN2+, the dual stain had similar sensitivity (83.4% vs 76.6%, P = .1), and statistically higher specificity (58.9% vs 49.6%, P < .001), PPV (21.0% vs 16.6%, P < .001), and NPV (96.4% vs 94.2%, P = .01) compared with cytology. Similar patterns were observed for CIN3+. Women with a positive test had high enough risk for referral to colposcopy, while the risk for women with negative tests was below a one-year return threshold based on current US management guidelines. Dual stain cytology showed good risk stratification for all HPV-positive women and for HPV-positive women with normal cytology. Additional follow-up is needed to determine how long dual stain negative women remain at low risk of precancer. Published by Oxford University Press 2015. This work is written by (a

  8. Perceived social pressure not to experience negative emotion is linked to selective attention for negative information.

    Science.gov (United States)

    Bastian, Brock; Pe, Madeline Lee; Kuppens, Peter

    2017-02-01

    Social norms and values may be important predictors of how people engage with and regulate their negative emotional experiences. Previous research has shown that social expectancies (the perceived social pressure not to feel negative emotion (NE)) exacerbate feelings of sadness. In the current research, we examined whether social expectancies may be linked to how people process emotional information. Using a modified classical flanker task involving emotional rather than non-emotional stimuli, we found that, for those who experienced low levels of NE, social expectancies were linked to the selective avoidance of negative emotional information. Those who experienced high levels of NE did not show a selective avoidance of negative emotional information. The findings suggest that, for people who experience many NEs, social expectancies may lead to discrepancies between how they think they ought to feel and the kind of emotional information they pay attention to.

  9. Central line-associated bloodstream infections in adult hematology patients with febrile neutropenia: an evaluation of surveillance definitions using differential time to blood culture positivity.

    Science.gov (United States)

    Freeman, Joshua T; Elinder-Camburn, Anna; McClymont, Catherine; Anderson, Deverick J; Bilkey, Mary; Williamson, Deborah A; Berkahn, Leanne; Roberts, Sally A

    2013-01-01

    We used differential time to positivity between central and peripheral blood cultures to evaluate the positive predictive value (PPV) of the National Healthcare Safety Network central line-associated bloodstream infection (CLABSI) surveillance definition among hematology patients with febrile neutropenia. The PPV was 27.7%, which suggests that, when the definition is applied to this population, CLABSI rates will be substantially overestimated.

  10. On Better Estimating and Normalizing the Relationship between Clinical Parameters: Comparing Respiratory Modulations in the Photoplethysmogram and Blood Pressure Signal (DPOP versus PPV

    Directory of Open Access Journals (Sweden)

    Paul S. Addison

    2015-01-01

    Full Text Available DPOP (ΔPOP or Delta-POP is a noninvasive parameter which measures the strength of respiratory modulations present in the pulse oximeter waveform. It has been proposed as a noninvasive alternative to pulse pressure variation (PPV used in the prediction of the response to volume expansion in hypovolemic patients. We considered a number of simple techniques for better determining the underlying relationship between the two parameters. It was shown numerically that baseline-induced signal errors were asymmetric in nature, which corresponded to observation, and we proposed a method which combines a least-median-of-squares estimator with the requirement that the relationship passes through the origin (the LMSO method. We further developed a method of normalization of the parameters through rescaling DPOP using the inverse gradient of the linear fitted relationship. We propose that this normalization method (LMSO-N is applicable to the matching of a wide range of clinical parameters. It is also generally applicable to the self-normalizing of parameters whose behaviour may change slightly due to algorithmic improvements.

  11. On better estimating and normalizing the relationship between clinical parameters: comparing respiratory modulations in the photoplethysmogram and blood pressure signal (DPOP versus PPV).

    Science.gov (United States)

    Addison, Paul S; Wang, Rui; Uribe, Alberto A; Bergese, Sergio D

    2015-01-01

    DPOP (ΔPOP or Delta-POP) is a noninvasive parameter which measures the strength of respiratory modulations present in the pulse oximeter waveform. It has been proposed as a noninvasive alternative to pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. We considered a number of simple techniques for better determining the underlying relationship between the two parameters. It was shown numerically that baseline-induced signal errors were asymmetric in nature, which corresponded to observation, and we proposed a method which combines a least-median-of-squares estimator with the requirement that the relationship passes through the origin (the LMSO method). We further developed a method of normalization of the parameters through rescaling DPOP using the inverse gradient of the linear fitted relationship. We propose that this normalization method (LMSO-N) is applicable to the matching of a wide range of clinical parameters. It is also generally applicable to the self-normalizing of parameters whose behaviour may change slightly due to algorithmic improvements.

  12. Clinical value of IS6110-based loop-mediated isothermal amplification for detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Aryan, Ehsan; Makvandi, Manoochehr; Farajzadeh, Ahmad; Huygen, Kris; Alvandi, Amir-Hooshang; Gouya, Mohammad-Mehdi; Sadrizadeh, Ali; Romano, Marta

    2013-06-01

    A fundamental to global tuberculosis (TB) control is timely and accurate diagnosis of infectious cases of the disease. Among various methods, techniques based on nucleic acid amplification are the ones with promising prospects. The present study evaluates the diagnostic value of the recently developed IS6110-based loop-mediated isothermal amplification (LAMP) for detection of Mycobacterium tuberculosis complex (MTBC) in sputum specimens. In this cross-sectional study (2008-2009), IS6110-LAMP was evaluated on 101 sputum specimens from 93 highly suspected TB patients and compared to Amplicor MTB test and in-house IS6110-PCR and -nested PCR assays. Culture results or clinical recovery following anti-TB therapy was considered as a reference to prove the TB cases. The overall sensitivity of IS6110-LAMP, Amplicor, nPCR, and PCR were respectively 89.6% (69/77 specimens; 95% confidence interval [CI], 80.5-95.4%), 76.6% (59/77 specimens; CI, 65.6-85.5%), 79.2% (61/77 specimens; CI, 68.5-87.6%) and 59.7% (46/77 specimens; CI, 47.9-70.8%). The specificity and positive predictive value (PPV) were 100% for all the tests, and the negative predictive value (NPV) of IS6110-LAMP, Amplicor, nPCR, and PCR were respectively 75%, 57.1%, 60%, and 43.6%. There was an excellent overall agreement between LAMP and nPCR (k 0.828), and between LAMP and Amplicor (k 0.746), in addition to a better tolerance of IS6110-LAMP to inhibitors present in clinical specimens. The better diagnostic performance of IS6110-LAMP compared to Amplicor (p = 0.009), nPCR (p = 0.013) and PCR (p < 0.0001) besides its rapidity, simplicity, and cost-effectiveness makes it a valuable method for the detection of MTBC in clinical samples, particularly in resource-limited settings. Copyright © 2013 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  13. The Effect of Social Network "Snapchat" on the Emergence of Some Negative Social Values (Social Hatred) Based on the Perspectives of Qassim Female Students: A Survey Study

    Science.gov (United States)

    Hussein, lawaheth M. T.

    2016-01-01

    The present study aims at detecting the effect of social media "Snapchat" on the emergence of some negative social values (social hatred ) based on the perspectives of female students enrolling at Qassim University, College of Science and Arts at ArRass, the academic year 2015/2016. The researcher has utilized the Descriptive Method…

  14. The brief negative symptom scale: psychometric properties.

    Science.gov (United States)

    Kirkpatrick, Brian; Strauss, Gregory P; Nguyen, Linh; Fischer, Bernard A; Daniel, David G; Cienfuegos, Angel; Marder, Stephen R

    2011-03-01

    The participants in the NIMH-MATRICS Consensus Development Conference on Negative Symptoms recommended that an instrument be developed that measured blunted affect, alogia, asociality, anhedonia, and avolition. The Brief Negative Symptom Scale (BNSS) is a 13-item instrument designed for clinical trials and other studies that measures these 5 domains. The interrater, test-retest, and internal consistency of the instrument were strong, with respective intraclass correlation coefficients of 0.93 for the BNSS total score and values of 0.89-0.95 for individual subscales. Comparisons with positive symptoms and other negative symptom instruments supported the discriminant and concurrent validity of the instrument.

  15. Risk factors for multidrug-resistant Gram-negative infection in burn patients.

    Science.gov (United States)

    Vickers, Mark L; Dulhunty, Joel M; Ballard, Emma; Chapman, Paul; Muller, Michael; Roberts, Jason A; Cotta, Menino O

    2018-05-01

    Infection with multidrug-resistant (MDR) Gram-negative organisms leads to poorer outcomes in the critically ill burn patient. The aim of this study was to identify the risk factors for MDR Gram-negative pathogen infection in critically ill burn patients admitted to a major tertiary referral intensive care unit (ICU) in Australia. A retrospective case-control study of all adult burn patients admitted over a 7-year period was conducted. Twenty-one cases that cultured an MDR Gram-negative organism were matched with 21 controls of similar age, gender, burn size and ICU stay. Multivariable conditional logistic regression was used to individually assess risk factors after adjusting for Acute Burn Severity Index. Adjusted odds ratios (ORs) were reported. P-values negative infection included superficial partial thickness burn size (OR: 1.08; 95% confidence interval (CI): 1.01-1.16; P-value: 0.034), prior meropenem exposure (OR: 10.39; 95% CI: 0.96-112.00; P-value: 0.054), Gram-negative colonization on admission (OR: 9.23; 95% CI: 0.65-130.15; P-value: 0.10) and escharotomy (OR: 2.66; 95% CI: 0.52-13.65; P-value: 0.24). For cases, mean age was 41 (SD: 13) years, mean total body surface area burned was 47% (SD: 18) and mean days in ICU until MDR specimen collection was 17 (SD: 10) days. Prior meropenem exposure, Gram-negative colonization on admission, escharotomy and superficial partial thickness burn size may be potentially important factors for increasing the risk of MDR Gram-negative infection in the critically ill burn patient. © 2017 Royal Australasian College of Surgeons.

  16. Multidetector computed tomography urography for diagnosing upper urinary tract urothelial tumour.

    Science.gov (United States)

    Cowan, Nigel C; Turney, Ben W; Taylor, Nia J; McCarthy, Catherine L; Crew, Jeremy P

    2007-06-01

    To evaluate multidetector computed tomography urography (MDCTU) for diagnosing upper urinary tract (UUT) urothelial tumour by comparison with retrograde ureteropyelography (RUP). MDCTU and RUP were used in a selected series of adult patients presenting with haematuria. Entry criteria were based on findings on intravenous urography and were chosen to ensure a high prevalence of UUT urothelial tumour to allow a valid retrospective comparison of the diagnostic techniques. MDCTU and RUP studies were scored for the presence and absence of UUT urothelial tumour by two radiologists, retrospectively and independently, and while unaware of the demographic and clinical information. The reference standards were the histopathology and clinical follow-up. MDCTU and RUP were used in 106 patients over a 24-month period. RUP was attempted in 151 of 212 UUTs; the corresponding MDCTU for each UUT was reviewed. MDCTU was a true-positive (TP) for urothelial tumour in 31, true-negative (TN) in 111, false-positive (FP) in eight and false-negative (FN) in one UUT, giving a sensitivity of 0.97, a specificity of 0.93, a positive predictive value (PPV) of 0.79 and a negative PV (NPV) of 0.99. RUP was technically successful and diagnostic in 96% of the UUTs (143/151). For diagnosing urothelial tumour, RUP was TP in 26, TN in 112, FP in four and FN in one UUT, giving a sensitivity of 0.97, specificity of 0.93, a PPV of 0.79 and NPV of 0.99. This study validates quantitatively the use of MDCTU for diagnosing UUT urothelial tumour.

  17. Value Chain Development as Alternative Method For Mapping Waste Management

    Directory of Open Access Journals (Sweden)

    Muhammad Saiful Hakim

    2017-06-01

    Full Text Available Solid Waste management begin at the household as waste of consumption and ended as a new form of waste product or recycling. Based on its value chain the subsequent process will have distict differences with manufacturing product. Value chain of manufacturing product will characterize as value added chain along the chain, where every side of the chain will generate positive chain. In the other hand, some parties of waste management value chain will negative value existed. Some parties in this chain will generate negative value solely because they must establish some cost for wipe the waste. Dissimilarities between value chain on product and waste will contribute to discrepancy between parties. Main purpose of this research is to identify value chain from solid waste management using value chain development. Another purpose to accomplished is to resolve discrepancy in value chain.  Research results shown that household is the parties that experiences negative value. To minimize the discrepancies there should be an action towards household

  18. Newly Diagnosed Breast Cancer: Comparison of Contrast-enhanced Spectral Mammography and Breast MR Imaging in the Evaluation of Extent of Disease.

    Science.gov (United States)

    Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita

    2017-11-01

    Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed

  19. Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease

    International Nuclear Information System (INIS)

    Meng, Lingdong; Cui, Lianqun; Cheng, Yuntao; Wu, Xiaoyan; Tang, Yuansheng; Wang, Yong; Xu, Fayun

    2009-01-01

    To evaluate the diagnostic accuracy of a dual-source computed tomography (DSCT) coronary angiography, with a particular focus on the effect of heart rate and calcifications. One hundred and nine patients with suspected coronary disease were divided into 2 groups according to a mean heart rate ( 400). Next, the effect of heart rate and calcification on the accuracy of coronary artery stenosis detection was analyzed by using an invasive coronary angiography as a reference standard. Coronary segments of less than 1.5 mm in diameter in an American Heart Association (AHA) 15-segment model were independently assessed. The mean heart rate during the scan was 71.8 bpm, whereas the mean Agatston score was 226.5. Of the 1,588 segments examined, 1,533 (97%) were assessable. A total of 17 patients had calcium scores above 400 Agatston U, whereas 50 had heart rates ≥ 70 bpm. Overall the sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for significant stenoses were: 95%, 91%, 65%, and 99% (by segment), respectively and 97%, 90%, 81%, and 91% (by artery), respectively (n = 475). Heart rate showed no significant impact on lesion detection; however, vessel calcification did show a significant impact on accuracy of assessment for coronary segments. The specificity, PPV and accuracy were 96%, 80%, and 96% (by segment), respectively for an Agatston score less than 100% and 99%, 96% and 98% (by artery). For an Agatston score of greater to or equal to 400 the specificity, PPV and accuracy were reduced to 79%, 55%, and 83% (by segment), respectively and to 79%, 69%, and 85% (by artery), respectively. The DSCT provides a high rate of accuracy for the detection of significant coronary artery disease, even in patients with high heart rates and evidence of coronary calcification. However, patients with severe coronary calcification (> 400 U) remain a challenge to diagnose

  20. Evaluation of national health-care related infection criteria for epidemiological surveillance in neonatology.

    Science.gov (United States)

    Ferreira, Janita; Bouzada, Maria C F; Jesus, Lenize A de; Cortes, Maria da Conceição Werneck; Armond, Guilherme A; Clemente, Wanessa T; Anchieta, Lêni M; Romanelli, Roberta M C

    2014-01-01

    to assess the use of the Brazilian criteria for reporting of hospital-acquired infections (HAIs) in the neonatal unit and compare them with the criteria proposed by the National Healthcare Safety Network (NHSN). this was a cross-sectional study conducted from 2009 to 2011. It included neonates with HAI reporting by at least one of the criteria. Statistical analysis included calculation of incidence density of HAIs, distribution by weight, and by reporting criterion. Analysis of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the national criteria was performed considering the NHSN as the gold standard, with agreement assessed by kappa. a total of 882 newborns were followed, and 330 had at least one infection notified by at least one of the criteria. A total of 522 HAIs were reported, regardless of the criteria. An incidence density of 27.28 infections per 1,000 patient-days was observed, and the main topographies were sepsis (58.3%), candidiasis (15.1%), and conjunctivitis (6.5%). A total of 489 (93.7%) were notified by both criteria, eight infections were notified only by the national criteria (six cases of necrotizing enterocolitis and two cases of conjunctivitis), and 25 cases of clinical sepsis were reported by NHSN criteria only. The sensitivity, specificity, PPV, and NPV were 95.1%, 98.6%, 98.4%, and 95.7%, respectively, for all topographies, and were 91.8%, 100%, 100%, and 96.3% for the analysis of sepsis. Kappa analysis showed an agreement of 96.9%. there was a high rate of agreement between the criteria. The use of the national criteria facilitates the reporting of sepsis in newborns, and can help to improve the specificity and PPV. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.