WorldWideScience

Sample records for validity pearson correlations

  1. Alternatives to Pearson's and Spearman's Correlation Coefficients

    OpenAIRE

    Smarandache, Florentin

    2008-01-01

    This article presents several alternatives to Pearson's correlation coefficient and many examples. In the samples where the rank in a discrete variable counts more than the variable values, the mixtures that we propose of Pearson's and Spearman's correlation coefficients give better results.

  2. Analytic posteriors for Pearson's correlation coefficient.

    Science.gov (United States)

    Ly, Alexander; Marsman, Maarten; Wagenmakers, Eric-Jan

    2018-02-01

    Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the (marginal) posterior for Pearson's correlation coefficient and all of the posterior moments are analytic. Our results are available in the open-source software package JASP.

  3. Analytic posteriors for Pearson's correlation coefficient

    OpenAIRE

    Ly, A.; Marsman, M.; Wagenmakers, E.-J.

    2018-01-01

    Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the (marginal) posterior for Pearson's correlation coefficient and all of the posterior moments are analytic. Our results are available in the open‐source software package JASP.

  4. Analytic posteriors for Pearson's correlation coefficient

    NARCIS (Netherlands)

    Ly, A.; Marsman, M.; Wagenmakers, E.-J.

    2018-01-01

    Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the

  5. The Evolution of Pearson's Correlation Coefficient

    Science.gov (United States)

    Kader, Gary D.; Franklin, Christine A.

    2008-01-01

    This article describes an activity for developing the notion of association between two quantitative variables. By exploring a collection of scatter plots, the authors propose a nonstandard "intuitive" measure of association; and by examining properties of this measure, they develop the more standard measure, Pearson's Correlation Coefficient. The…

  6. An efficient sensitivity analysis method for modified geometry of Macpherson suspension based on Pearson correlation coefficient

    Science.gov (United States)

    Shojaeefard, Mohammad Hasan; Khalkhali, Abolfazl; Yarmohammadisatri, Sadegh

    2017-06-01

    The main purpose of this paper is to propose a new method for designing Macpherson suspension, based on the Sobol indices in terms of Pearson correlation which determines the importance of each member on the behaviour of vehicle suspension. The formulation of dynamic analysis of Macpherson suspension system is developed using the suspension members as the modified links in order to achieve the desired kinematic behaviour. The mechanical system is replaced with an equivalent constrained links and then kinematic laws are utilised to obtain a new modified geometry of Macpherson suspension. The equivalent mechanism of Macpherson suspension increased the speed of analysis and reduced its complexity. The ADAMS/CAR software is utilised to simulate a full vehicle, Renault Logan car, in order to analyse the accuracy of modified geometry model. An experimental 4-poster test rig is considered for validating both ADAMS/CAR simulation and analytical geometry model. Pearson correlation coefficient is applied to analyse the sensitivity of each suspension member according to vehicle objective functions such as sprung mass acceleration, etc. Besides this matter, the estimation of Pearson correlation coefficient between variables is analysed in this method. It is understood that the Pearson correlation coefficient is an efficient method for analysing the vehicle suspension which leads to a better design of Macpherson suspension system.

  7. Pearson's correlation coefficient in the theory of networks: A comment

    OpenAIRE

    Ahmed, Zafar; Kumar, Sachin

    2018-01-01

    In statistics, the Pearson correlation coefficient $r_{x,y}$ determines the degree of linear correlation between two variables and it is known that $-1 \\le r_{x,y} \\le 1$. In the theory of networks, a curious expression proposed in [PRL {\\bf 89} 208701 (2002)] for degree-degree correlation coefficient $r_{j_i,k_i}, i\\in [1,M]$ has been in use. We realize that the suggested form is the conventional Pearson's coefficient for $\\{(j_i,k_i), (k_i,j_i)\\}$ for $2M$ data points and hence it is rightl...

  8. Pearson's chi-square test and rank correlation inferences for clustered data.

    Science.gov (United States)

    Shih, Joanna H; Fay, Michael P

    2017-09-01

    Pearson's chi-square test has been widely used in testing for association between two categorical responses. Spearman rank correlation and Kendall's tau are often used for measuring and testing association between two continuous or ordered categorical responses. However, the established statistical properties of these tests are only valid when each pair of responses are independent, where each sampling unit has only one pair of responses. When each sampling unit consists of a cluster of paired responses, the assumption of independent pairs is violated. In this article, we apply the within-cluster resampling technique to U-statistics to form new tests and rank-based correlation estimators for possibly tied clustered data. We develop large sample properties of the new proposed tests and estimators and evaluate their performance by simulations. The proposed methods are applied to a data set collected from a PET/CT imaging study for illustration. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  9. Sample size for estimation of the Pearson correlation coefficient in cherry tomato tests

    Directory of Open Access Journals (Sweden)

    Bruno Giacomini Sari

    2017-09-01

    Full Text Available ABSTRACT: The aim of this study was to determine the required sample size for estimation of the Pearson coefficient of correlation between cherry tomato variables. Two uniformity tests were set up in a protected environment in the spring/summer of 2014. The observed variables in each plant were mean fruit length, mean fruit width, mean fruit weight, number of bunches, number of fruits per bunch, number of fruits, and total weight of fruits, with calculation of the Pearson correlation matrix between them. Sixty eight sample sizes were planned for one greenhouse and 48 for another, with the initial sample size of 10 plants, and the others were obtained by adding five plants. For each planned sample size, 3000 estimates of the Pearson correlation coefficient were obtained through bootstrap re-samplings with replacement. The sample size for each correlation coefficient was determined when the 95% confidence interval amplitude value was less than or equal to 0.4. Obtaining estimates of the Pearson correlation coefficient with high precision is difficult for parameters with a weak linear relation. Accordingly, a larger sample size is necessary to estimate them. Linear relations involving variables dealing with size and number of fruits per plant have less precision. To estimate the coefficient of correlation between productivity variables of cherry tomato, with a confidence interval of 95% equal to 0.4, it is necessary to sample 275 plants in a 250m² greenhouse, and 200 plants in a 200m² greenhouse.

  10. Metric distances derived from cosine similarity and Pearson and Spearman correlations

    OpenAIRE

    van Dongen, Stijn; Enright, Anton J.

    2012-01-01

    We investigate two classes of transformations of cosine similarity and Pearson and Spearman correlations into metric distances, utilising the simple tool of metric-preserving functions. The first class puts anti-correlated objects maximally far apart. Previously known transforms fall within this class. The second class collates correlated and anti-correlated objects. An example of such a transformation that yields a metric distance is the sine function when applied to centered data.

  11. Requirements for a cocitation similarity measure, with special reference to Pearson's correlation coefficient

    OpenAIRE

    Ahlgren, P.; Jarneving, B.; ROUSSEAU, Ronald

    2003-01-01

    Author cocitation analysis (ACA), a special type of cocitation analysis, was introduced by White and Griffith in 1981. This technique is used to analyze the intellectual structure of a given scientific field. In 1990, McCain published a technical overview that has been largely adopted as a standard. Here, McCain notes that Pearson's correlation coefficient (Pearson's r) is often used as a similarity measure in ACA and presents some advantages of its use. The present article criticizes the use...

  12. Colocalization analysis in fluorescence micrographs: verification of a more accurate calculation of pearson's correlation coefficient.

    Science.gov (United States)

    Barlow, Andrew L; Macleod, Alasdair; Noppen, Samuel; Sanderson, Jeremy; Guérin, Christopher J

    2010-12-01

    One of the most routine uses of fluorescence microscopy is colocalization, i.e., the demonstration of a relationship between pairs of biological molecules. Frequently this is presented simplistically by the use of overlays of red and green images, with areas of yellow indicating colocalization of the molecules. Colocalization data are rarely quantified and can be misleading. Our results from both synthetic and biological datasets demonstrate that the generation of Pearson's correlation coefficient between pairs of images can overestimate positive correlation and fail to demonstrate negative correlation. We have demonstrated that the calculation of a thresholded Pearson's correlation coefficient using only intensity values over a determined threshold in both channels produces numerical values that more accurately describe both synthetic datasets and biological examples. Its use will bring clarity and accuracy to colocalization studies using fluorescent microscopy.

  13. Ghost imaging based on Pearson correlation coefficients

    International Nuclear Information System (INIS)

    Yu Wen-Kai; Yao Xu-Ri; Liu Xue-Feng; Li Long-Zhen; Zhai Guang-Jie

    2015-01-01

    Correspondence imaging is a new modality of ghost imaging, which can retrieve a positive/negative image by simple conditional averaging of the reference frames that correspond to relatively large/small values of the total intensity measured at the bucket detector. Here we propose and experimentally demonstrate a more rigorous and general approach in which a ghost image is retrieved by calculating a Pearson correlation coefficient between the bucket detector intensity and the brightness at a given pixel of the reference frames, and at the next pixel, and so on. Furthermore, we theoretically provide a statistical interpretation of these two imaging phenomena, and explain how the error depends on the sample size and what kind of distribution the error obeys. According to our analysis, the image signal-to-noise ratio can be greatly improved and the sampling number reduced by means of our new method. (paper)

  14. Pearson's Correlation between Three Variables; Using Students' Basic Knowledge of Geometry for an Exercise in Mathematical Statistics

    Science.gov (United States)

    Vos, Pauline

    2009-01-01

    When studying correlations, how do the three bivariate correlation coefficients between three variables relate? After transforming Pearson's correlation coefficient r into a Euclidean distance, undergraduate students can tackle this problem using their secondary school knowledge of geometry (Pythagoras' theorem and similarity of triangles).…

  15. Correlation Between Posttraumatic Growth and Posttraumatic Stress Disorder Symptoms Based on Pearson Correlation Coefficient: A Meta-Analysis.

    Science.gov (United States)

    Liu, An-Nuo; Wang, Lu-Lu; Li, Hui-Ping; Gong, Juan; Liu, Xiao-Hong

    2017-05-01

    The literature on posttraumatic growth (PTG) is burgeoning, with the inconsistencies in the literature of the relationship between PTG and posttraumatic stress disorder (PTSD) symptoms becoming a focal point of attention. Thus, this meta-analysis aims to explore the relationship between PTG and PTSD symptoms through the Pearson correlation coefficient. A systematic search of the literature from January 1996 to November 2015 was completed. We retrieved reports on 63 studies that involved 26,951 patients. The weighted correlation coefficient revealed an effect size of 0.22 with a 95% confidence interval of 0.18 to 0.25. Meta-analysis provides evidence that PTG may be positively correlated with PTSD symptoms and that this correlation may be modified by age, trauma type, and time since trauma. Accordingly, people with high levels of PTG should not be ignored, but rather, they should continue to receive help to alleviate their PTSD symptoms.

  16. Computer aided diagnosis system for Alzheimer disease using brain diffusion tensor imaging features selected by Pearson's correlation.

    Science.gov (United States)

    Graña, M; Termenon, M; Savio, A; Gonzalez-Pinto, A; Echeveste, J; Pérez, J M; Besga, A

    2011-09-20

    The aim of this paper is to obtain discriminant features from two scalar measures of Diffusion Tensor Imaging (DTI) data, Fractional Anisotropy (FA) and Mean Diffusivity (MD), and to train and test classifiers able to discriminate Alzheimer's Disease (AD) patients from controls on the basis of features extracted from the FA or MD volumes. In this study, support vector machine (SVM) classifier was trained and tested on FA and MD data. Feature selection is done computing the Pearson's correlation between FA or MD values at voxel site across subjects and the indicative variable specifying the subject class. Voxel sites with high absolute correlation are selected for feature extraction. Results are obtained over an on-going study in Hospital de Santiago Apostol collecting anatomical T1-weighted MRI volumes and DTI data from healthy control subjects and AD patients. FA features and a linear SVM classifier achieve perfect accuracy, sensitivity and specificity in several cross-validation studies, supporting the usefulness of DTI-derived features as an image-marker for AD and to the feasibility of building Computer Aided Diagnosis systems for AD based on them. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Asymptotic properties of Pearson's rank-variate correlation coefficient under contaminated Gaussian model.

    Science.gov (United States)

    Ma, Rubao; Xu, Weichao; Zhang, Yun; Ye, Zhongfu

    2014-01-01

    This paper investigates the robustness properties of Pearson's rank-variate correlation coefficient (PRVCC) in scenarios where one channel is corrupted by impulsive noise and the other is impulsive noise-free. As shown in our previous work, these scenarios that frequently encountered in radar and/or sonar, can be well emulated by a particular bivariate contaminated Gaussian model (CGM). Under this CGM, we establish the asymptotic closed forms of the expectation and variance of PRVCC by means of the well known Delta method. To gain a deeper understanding, we also compare PRVCC with two other classical correlation coefficients, i.e., Spearman's rho (SR) and Kendall's tau (KT), in terms of the root mean squared error (RMSE). Monte Carlo simulations not only verify our theoretical findings, but also reveal the advantage of PRVCC by an example of estimating the time delay in the particular impulsive noise environment.

  18. Pearson's Functions to Describe FSW Weld Geometry

    International Nuclear Information System (INIS)

    Lacombe, D.; Coupard, D.; Tcherniaeff, S.; Girot, F.; Gutierrez-Orrantia, M. E.

    2011-01-01

    Friction stir welding (FSW) is a relatively new joining technique particularly for aluminium alloys that are difficult to fusion weld. In this study, the geometry of the weld has been investigated and modelled using Pearson's functions. It has been demonstrated that the Pearson's parameters (mean, standard deviation, skewness, kurtosis and geometric constant) can be used to characterize the weld geometry and the tensile strength of the weld assembly. Pearson's parameters and process parameters are strongly correlated allowing to define a control process procedure for FSW assemblies which make radiographic or ultrasonic controls unnecessary. Finally, an optimisation using a Generalized Gradient Method allows to determine the geometry of the weld which maximises the assembly tensile strength.

  19. Establishing construct validity for the thyroid-specific patient reported outcome measure (ThyPRO)

    DEFF Research Database (Denmark)

    Watt, Torquil; Bjorner, Jakob Bue; Groenvold, Mogens

    2009-01-01

    , evaluating lack of convergent validity (item-own scale polyserial correlation correlation higher than item-own scale correlation) of the hypothesized scale structure. Analyses were repeated in clinical and sociodemographic subgroups and with Pearson...... complete convergent validity and only two instances of lack of discriminant validity. Pearson correlations yielded similar results. Across all subgroups, convergent validity was complete, and discriminant validity was found in 99.2% of tests. Lack of discriminant validity was mainly between physical...... correlations. Reliability was estimated by Cronbach's alpha, both conventionally and with polychoric correlations. RESULTS: In total, 904 patients (69%) responded. Initial multitrait scaling analysis identified 25 scaling errors. Twelve items were omitted from the scale structure, and a re-analysis showed...

  20. Health Service Quality Scale: Brazilian Portuguese translation, reliability and validity.

    Science.gov (United States)

    Rocha, Luiz Roberto Martins; Veiga, Daniela Francescato; e Oliveira, Paulo Rocha; Song, Elaine Horibe; Ferreira, Lydia Masako

    2013-01-17

    The Health Service Quality Scale is a multidimensional hierarchical scale that is based on interdisciplinary approach. This instrument was specifically created for measuring health service quality based on marketing and health care concepts. The aim of this study was to translate and culturally adapt the Health Service Quality Scale into Brazilian Portuguese and to assess the validity and reliability of the Brazilian Portuguese version of the instrument. We conducted a cross-sectional, observational study, with public health system patients in a Brazilian university hospital. Validity was assessed using Pearson's correlation coefficient to measure the strength of the association between the Brazilian Portuguese version of the instrument and the SERVQUAL scale. Internal consistency was evaluated using Cronbach's alpha coefficient; the intraclass (ICC) and Pearson's correlation coefficients were used for test-retest reliability. One hundred and sixteen consecutive postoperative patients completed the questionnaire. Pearson's correlation coefficient for validity was 0.20. Cronbach's alpha for the first and second administrations of the final version of the instrument were 0.982 and 0.986, respectively. For test-retest reliability, Pearson's correlation coefficient was 0.89 and ICC was 0.90. The culturally adapted, Brazilian Portuguese version of the Health Service Quality Scale is a valid and reliable instrument to measure health service quality.

  1. SPSS and SAS programs for comparing Pearson correlations and OLS regression coefficients.

    Science.gov (United States)

    Weaver, Bruce; Wuensch, Karl L

    2013-09-01

    Several procedures that use summary data to test hypotheses about Pearson correlations and ordinary least squares regression coefficients have been described in various books and articles. To our knowledge, however, no single resource describes all of the most common tests. Furthermore, many of these tests have not yet been implemented in popular statistical software packages such as SPSS and SAS. In this article, we describe all of the most common tests and provide SPSS and SAS programs to perform them. When they are applicable, our code also computes 100 × (1 - α)% confidence intervals corresponding to the tests. For testing hypotheses about independent regression coefficients, we demonstrate one method that uses summary data and another that uses raw data (i.e., Potthoff analysis). When the raw data are available, the latter method is preferred, because use of summary data entails some loss of precision due to rounding.

  2. Online physician review websites poorly correlate to a validated metric of patient satisfaction.

    Science.gov (United States)

    Chen, Jennwood; Presson, Angela; Zhang, Chong; Ray, David; Finlayson, Samuel; Glasgow, Robert

    2018-07-01

    Physician review websites such as Vitals and Healthgrades are becoming an increasingly popular tool for patients to choose providers. We hypothesized that the scores of these surveys poorly represent the true value of patient satisfaction when compared to a validated survey instrument. Answers from Vitals and Healthgrades online surveys were compared to the Press Ganey Medical Practice Survey (PGMPS) for 200 faculty members at a university hospital for FY15. Weighted Pearson's correlation was used to compare Healthgrades and Vitals to PGMPS. While statistically significant, both Vitals and Healthgrades had very low correlations with the PGMPS with weighted coefficients of 0.18 (95% confidence interval: 0.02-0.34, P = 0.025) and 0.27 (95% confidence interval: 0.12-0.42, P Online physician rating websites such as Vitals and Healthgrades poorly correlate with the PGMPS, a validated measure of patient satisfaction. Patients should be aware of these limitations and, consequently, should have access to the most accurate measure of patient satisfaction. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Application of Linear Mixed-Effects Models in Human Neuroscience Research: A Comparison with Pearson Correlation in Two Auditory Electrophysiology Studies.

    Science.gov (United States)

    Koerner, Tess K; Zhang, Yang

    2017-02-27

    Neurophysiological studies are often designed to examine relationships between measures from different testing conditions, time points, or analysis techniques within the same group of participants. Appropriate statistical techniques that can take into account repeated measures and multivariate predictor variables are integral and essential to successful data analysis and interpretation. This work implements and compares conventional Pearson correlations and linear mixed-effects (LME) regression models using data from two recently published auditory electrophysiology studies. For the specific research questions in both studies, the Pearson correlation test is inappropriate for determining strengths between the behavioral responses for speech-in-noise recognition and the multiple neurophysiological measures as the neural responses across listening conditions were simply treated as independent measures. In contrast, the LME models allow a systematic approach to incorporate both fixed-effect and random-effect terms to deal with the categorical grouping factor of listening conditions, between-subject baseline differences in the multiple measures, and the correlational structure among the predictor variables. Together, the comparative data demonstrate the advantages as well as the necessity to apply mixed-effects models to properly account for the built-in relationships among the multiple predictor variables, which has important implications for proper statistical modeling and interpretation of human behavior in terms of neural correlates and biomarkers.

  4. Modules Identification in Gene Positive Networks of Hepatocellular Carcinoma Using Pearson Agglomerative Method and Pearson Cohesion Coupling Modularity

    Directory of Open Access Journals (Sweden)

    Jinyu Hu

    2012-01-01

    Full Text Available In this study, a gene positive network is proposed based on a weighted undirected graph, where the weight represents the positive correlation of the genes. A Pearson agglomerative clustering algorithm is employed to build a clustering tree, where dotted lines cut the tree from bottom to top leading to a number of subsets of the modules. In order to achieve better module partitions, the Pearson correlation coefficient modularity is addressed to seek optimal module decomposition by selecting an optimal threshold value. For the liver cancer gene network under study, we obtain a strong threshold value at 0.67302, and a very strong correlation threshold at 0.80086. On the basis of these threshold values, fourteen strong modules and thirteen very strong modules are obtained respectively. A certain degree of correspondence between the two types of modules is addressed as well. Finally, the biological significance of the two types of modules is analyzed and explained, which shows that these modules are closely related to the proliferation and metastasis of liver cancer. This discovery of the new modules may provide new clues and ideas for liver cancer treatment.

  5. The Pearson IV distribution and its application to ion implanted depth profiles

    International Nuclear Information System (INIS)

    Wilson, R.G.

    1980-01-01

    The Pearson IV distribution system is analyzed to determine the regions of validity for the values of the moments that produce convex, concave, more pointed than Gaussian, and more flat-topped than Gaussian distributions; the limits beyond which no significant change in distribution is produced; and excluded regions. These regions are illustrated in a figure that can be used to facilitate the determination of the Pearson IV moments for experimental ion implanted depth distributions. Examples are given of Pearson IV distributions to illustrate the effects of the ranges of skewness, kurtosis, and standard deviation, for both more pointed and more flat-topped than Gaussian distributions. A procedure is described for matching experimental ion implanted depth distributions to computer plotted Pearson IV modified Gaussian distributions. A few experimental curves are given to illustrate the different types of Pearson IV curves, and accuracies of moments are discussed. (author)

  6. Correlação de pearson e análise de trilha identificando variáveis para caracterizar porta-enxerto de Pyrus communis L Pearson correlation and path analysis identifying variables for the characterization of Pyrus communis L. rootstock

    Directory of Open Access Journals (Sweden)

    Simone Padilha Galarça

    2010-08-01

    Full Text Available Objetivou-se, no presente trabalho, através de correlação de Pearson e análise de trilha, identificar variáveis para caracterizar porta-enxertos ananizantes para a cultura da pereira (Pyrus communis L.. Neste experimento foram utilizadas 49 plantas de pereira, plantadas nos canteiros do Departamento de Fitotecnia da FAEM/UFPel. As plantas foram avaliadas na época do seu crescimento vegetativo, segundo parâmetros descritos em instruções do Ministério da Agricultura, Pecuária e Abastecimento. Pela correlação de Pearson, as variáveis VP, NRP, HCP e FCNPRCL se destacaram. Na análise de trilha, a variável número de lenticelas obteve maior efeito positivo sobre VP, NRP e FCNPRCL, a variável ramificação do ramo demonstrou-se com efeito positivo sobre HCP, sendo essas duas variáveis consideradas eficazes no processo de seleção de porta-enxerto juntamente com as variáveis básicas.The objective of this work was to identify, through the Pearson correlation and path analysis, variables to characterize rootstocks suitable for the cultivation of the pear (Pyrus communis L.. In this experiment 49 pear specimens were used, planted in flowerbeds at the Phytotechny Department. The plants were evaluated at the time of growth, according to parameters described in the instructions of the Ministério da Agricultura, Pecuária e Abastecimento. According to the Pearson correlation, the variables VP, NRP, ETA and FCNPRCL stood out. In path analysis, the variable number of lenticels had a more positive effect on VP, NRP and FCNPRCL, variable branch of the industry had a more positive effect on ETA. Both variables were considered effective in the process of selection of rootstock together with the basic variables.

  7. Method for stationarity-segmentation of spike train data with application to the Pearson cross-correlation.

    Science.gov (United States)

    Quiroga-Lombard, Claudio S; Hass, Joachim; Durstewitz, Daniel

    2013-07-01

    Correlations among neurons are supposed to play an important role in computation and information coding in the nervous system. Empirically, functional interactions between neurons are most commonly assessed by cross-correlation functions. Recent studies have suggested that pairwise correlations may indeed be sufficient to capture most of the information present in neural interactions. Many applications of correlation functions, however, implicitly tend to assume that the underlying processes are stationary. This assumption will usually fail for real neurons recorded in vivo since their activity during behavioral tasks is heavily influenced by stimulus-, movement-, or cognition-related processes as well as by more general processes like slow oscillations or changes in state of alertness. To address the problem of nonstationarity, we introduce a method for assessing stationarity empirically and then "slicing" spike trains into stationary segments according to the statistical definition of weak-sense stationarity. We examine pairwise Pearson cross-correlations (PCCs) under both stationary and nonstationary conditions and identify another source of covariance that can be differentiated from the covariance of the spike times and emerges as a consequence of residual nonstationarities after the slicing process: the covariance of the firing rates defined on each segment. Based on this, a correction of the PCC is introduced that accounts for the effect of segmentation. We probe these methods both on simulated data sets and on in vivo recordings from the prefrontal cortex of behaving rats. Rather than for removing nonstationarities, the present method may also be used for detecting significant events in spike trains.

  8. External validation of a normal tissue complication probability model for radiation-induced hypothyroidism in an independent cohort

    DEFF Research Database (Denmark)

    Rønjom, Marianne F; Brink, Carsten; Bentzen, Søren M

    2015-01-01

    blood tests in the validation cohort relative to the original cohort. However, Pearson's correlation coefficients between model and clinical outcome were high: r = 0.97 estimated by the original model versus the original cohort, and r = 0.97 estimated by the original model versus the new cohort....... CONCLUSION: Dmean and Vthyroid were significant predictors of RIHT in both cohorts. The original NTCP model demonstrated external validity owing to high Pearson's correlation coefficients between estimated and observed incidence rates of RIHT in the original as well as in the validation cohort. This model...

  9. Polychoric/Tetrachoric Matrix or Pearson Matrix? A methodological study

    Directory of Open Access Journals (Sweden)

    Dominguez Lara, Sergio Alexis

    2014-04-01

    Full Text Available The use of product-moment correlation of Pearson is common in most studies in factor analysis in psychology, but it is known that this statistic is only applicable when the variables related are in interval scale and normally distributed, and when are used in ordinal data may to produce a distorted correlation matrix . Thus is a suitable option using polychoric/tetrachoric matrices in item-level factor analysis when the items are in level measurement nominal or ordinal. The aim of this study was to show the differences in the KMO, Bartlett`s Test and Determinant of the Matrix, percentage of variance explained and factor loadings in depression trait scale of Depression Inventory Trait - State and the Neuroticism dimension of the short form of the Eysenck Personality Questionnaire -Revised, regarding the use of matrices polychoric/tetrachoric matrices and Pearson. These instruments was analyzed with different extraction methods (Maximum Likelihood, Minimum Rank Factor Analysis, Unweighted Least Squares and Principal Components, keeping constant the rotation method Promin were analyzed. Were observed differences regarding sample adequacy measures, as well as with respect to the explained variance and the factor loadings, for solutions having as polychoric/tetrachoric matrix. So it can be concluded that the polychoric / tetrachoric matrix give better results than Pearson matrices when it comes to item-level factor analysis using different methods.

  10. Genetics Home Reference: Pearson marrow-pancreas syndrome

    Science.gov (United States)

    ... Health Conditions Pearson marrow-pancreas syndrome Pearson marrow-pancreas syndrome Printable PDF Open All Close All Enable ... view the expand/collapse boxes. Description Pearson marrow-pancreas syndrome is a severe disorder that usually begins ...

  11. A new method to detect event-related potentials based on Pearson's correlation.

    Science.gov (United States)

    Giroldini, William; Pederzoli, Luciano; Bilucaglia, Marco; Melloni, Simone; Tressoldi, Patrizio

    2016-12-01

    Event-related potentials (ERPs) are widely used in brain-computer interface applications and in neuroscience.  Normal EEG activity is rich in background noise, and therefore, in order to detect ERPs, it is usually necessary to take the average from multiple trials to reduce the effects of this noise.  The noise produced by EEG activity itself is not correlated with the ERP waveform and so, by calculating the average, the noise is decreased by a factor inversely proportional to the square root of N , where N is the number of averaged epochs. This is the easiest strategy currently used to detect ERPs, which is based on calculating the average of all ERP's waveform, these waveforms being time- and phase-locked.  In this paper, a new method called GW6 is proposed, which calculates the ERP using a mathematical method based only on Pearson's correlation. The result is a graph with the same time resolution as the classical ERP and which shows only positive peaks representing the increase-in consonance with the stimuli-in EEG signal correlation over all channels.  This new method is also useful for selectively identifying and highlighting some hidden components of the ERP response that are not phase-locked, and that are usually hidden in the standard and simple method based on the averaging of all the epochs.  These hidden components seem to be caused by variations (between each successive stimulus) of the ERP's inherent phase latency period (jitter), although the same stimulus across all EEG channels produces a reasonably constant phase. For this reason, this new method could be very helpful to investigate these hidden components of the ERP response and to develop applications for scientific and medical purposes. Moreover, this new method is more resistant to EEG artifacts than the standard calculations of the average and could be very useful in research and neurology.  The method we are proposing can be directly used in the form of a process written in the well

  12. The development and validation of using inertial sensors to monitor postural change in resistance exercise.

    Science.gov (United States)

    Gleadhill, Sam; Lee, James Bruce; James, Daniel

    2016-05-03

    This research presented and validated a method of assessing postural changes during resistance exercise using inertial sensors. A simple lifting task was broken down to a series of well-defined tasks, which could be examined and measured in a controlled environment. The purpose of this research was to determine whether timing measures obtained from inertial sensor accelerometer outputs are able to provide accurate, quantifiable information of resistance exercise movement patterns. The aim was to complete a timing measure validation of inertial sensor outputs. Eleven participants completed five repetitions of 15 different deadlift variations. Participants were monitored with inertial sensors and an infrared three dimensional motion capture system. Validation was undertaken using a Will Hopkins Typical Error of the Estimate, with a Pearson׳s correlation and a Bland Altman Limits of Agreement analysis. Statistical validation measured the timing agreement during deadlifts, from inertial sensor outputs and the motion capture system. Timing validation results demonstrated a Pearson׳s correlation of 0.9997, with trivial standardised error (0.026) and standardised bias (0.002). Inertial sensors can now be used in practical settings with as much confidence as motion capture systems, for accelerometer timing measurements of resistance exercise. This research provides foundations for inertial sensors to be applied for qualitative activity recognition of resistance exercise and safe lifting practices. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Validation of general job satisfaction in the Korean Labor and Income Panel Study.

    Science.gov (United States)

    Park, Shin Goo; Hwang, Sang Hee

    2017-01-01

    The purpose of this study is to assess the validity and reliability of general job satisfaction (JS) in the Korean Labor and Income Panel Study (KLIPS). We used the data from the 17th wave (2014) of the nationwide KLIPS, which selected a representative panel sample of Korean households and individuals aged 15 or older residing in urban areas. We included in this study 7679 employed subjects (4529 males and 3150 females). The general JS instrument consisted of five items rated on a scale from 1 (strongly disagree) to 5 (strongly agree). The general JS reliability was assessed using the corrected item-total correlation and Cronbach's alpha coefficient. The validity of general JS was assessed using confirmatory factor analysis (CFA) and Pearson's correlation. The corrected item-total correlations ranged from 0.736 to 0.837. Therefore, no items were removed. Cronbach's alpha for general JS was 0.925, indicating excellent internal consistency. The CFA of the general JS model showed a good fit. Pearson's correlation coefficients for convergent validity showed moderate or strong correlations. The results obtained in our study confirm the validity and reliability of general JS.

  14. Reliability and validity of the modifiable activity questionnaire for an Iranian urban adolescent population

    Directory of Open Access Journals (Sweden)

    Maryam Delshad

    2015-01-01

    Full Text Available Background: The purpose of this study was to evaluate the validity and reliability on the Persian translation of the Modifiable Activity Questionnaire (MAQ in a sample of Tehranian adolescents. Methods: Of a total of 52 subjects, a sub-sample of 40 participations (55.0% boys was used to assess the reliability and the validity of the physical activity questionnaire. The reliability of the two MAQs was calculated by intraclass correlation coefficients, and validation was evaluated using Pearson correlation coefficients to compare data between mean of the two MAQs and mean of four physical activity records. Results: Intraclass correlation coefficient was calculated to assess the reliability between two MAQs and the results of leisure time physical activity over the past year were 0.97. Pearson correlation coefficients between mean of two MAQs and mean of four physical activity records were 0.49 (P < 0.001, for leisure time physical activities. Conclusions: High reliability and relatively moderate validity were found for the Persian translation of the MAQ in a Tehranian adolescent population. Further studies with large sample size are suggested to assess the validity more precisely.

  15. Validation of a scenario-based assessment of critical thinking using an externally validated tool.

    Science.gov (United States)

    Buur, Jennifer L; Schmidt, Peggy; Smylie, Dean; Irizarry, Kris; Crocker, Carlos; Tyler, John; Barr, Margaret

    2012-01-01

    With medical education transitioning from knowledge-based curricula to competency-based curricula, critical thinking skills have emerged as a major competency. While there are validated external instruments for assessing critical thinking, many educators have created their own custom assessments of critical thinking. However, the face validity of these assessments has not been challenged. The purpose of this study was to compare results from a custom assessment of critical thinking with the results from a validated external instrument of critical thinking. Students from the College of Veterinary Medicine at Western University of Health Sciences were administered a custom assessment of critical thinking (ACT) examination and the externally validated instrument, California Critical Thinking Skills Test (CCTST), in the spring of 2011. Total scores and sub-scores from each exam were analyzed for significant correlations using Pearson correlation coefficients. Significant correlations between ACT Blooms 2 and deductive reasoning and total ACT score and deductive reasoning were demonstrated with correlation coefficients of 0.24 and 0.22, respectively. No other statistically significant correlations were found. The lack of significant correlation between the two examinations illustrates the need in medical education to externally validate internal custom assessments. Ultimately, the development and validation of custom assessments of non-knowledge-based competencies will produce higher quality medical professionals.

  16. An automated Pearson's correlation change classification (APC3) approach for GC/MS metabonomic data using total ion chromatograms (TICs).

    Science.gov (United States)

    Prakash, Bhaskaran David; Esuvaranathan, Kesavan; Ho, Paul C; Pasikanti, Kishore Kumar; Chan, Eric Chun Yong; Yap, Chun Wei

    2013-05-21

    A fully automated and computationally efficient Pearson's correlation change classification (APC3) approach is proposed and shown to have overall comparable performance with both an average accuracy and an average AUC of 0.89 ± 0.08 but is 3.9 to 7 times faster, easier to use and have low outlier susceptibility in contrast to other dimensional reduction and classification combinations using only the total ion chromatogram (TIC) intensities of GC/MS data. The use of only the TIC permits the possible application of APC3 to other metabonomic data such as LC/MS TICs or NMR spectra. A RapidMiner implementation is available for download at http://padel.nus.edu.sg/software/padelapc3.

  17. Repeatability and relative validity of a quantitative food-frequency questionnaire among French adults

    Directory of Open Access Journals (Sweden)

    Emmanuel Barrat

    2012-10-01

    Full Text Available Background: A 50-item self-administered food frequency questionnaire (FFQ was developed for French adults, to assess the intake of energy, 10 macronutrients, 11 vitamins, and 11 minerals, and to be used in the context of a medical consultation. Objective: To assess the repeatability and relative validity of this FFQ compared to a 7-day diet record (7-DR. Design: A total of 54 and 100 French adults were included in the repeatability and validation studies, respectively. Repeatability was assessed using two FFQs, the second carried out 3 weeks after the first. In the validation study, subjects first completed the FFQ, then the 7-DR the following week. Energy and nutrient intakes were compared using Pearson correlation. The degree of misclassification by the FFQ, compared to the 7-DR, was calculated by a contingency table of quintiles. Bland–Altman plots assessed the correlation between FFQ and 7-DR across the intake range. Results: Repeatability for intake, explored by Pearson correlation, was 0.62–0.90 (median: 0.81. Relative validity, as determined by Pearson correlation for the nutrient intake derived from the FFQ and 7-DR, was 0.36–0.80 (0.64. The FFQ tended to report higher fiber and micronutrient intake than 7-DR. Misclassification into opposite quintiles ranged 0–6% (1%, whereas classification into same or adjacent quintiles ranged 59–83% (74%. Bland–Altman plots showed good agreement for most nutrients across the range of intake. Conclusion: This new FFQ showed a high repeatability and good relative validity, and thanks to its short length, should be a useful tool for rapidly evaluating the nutrient intake of French adults.

  18. Concurrent Validity of Physiological Cost Index in Walking over Ground and during Robotic Training in Subacute Stroke Patients

    Directory of Open Access Journals (Sweden)

    Anna Sofia Delussu

    2014-01-01

    Full Text Available Physiological Cost Index (PCI has been proposed to assess gait demand. The purpose of the study was to establish whether PCI is a valid indicator in subacute stroke patients of energy cost of walking in different walking conditions, that is, over ground and on the Gait Trainer (GT with body weight support (BWS. The study tested if correlations exist between PCI and ECW, indicating validity of the measure and, by implication, validity of PCI. Six patients (patient group (PG with subacute stroke and 6 healthy age- and size-matched subjects as control group (CG performed, in a random sequence in different days, walking tests overground and on the GT with 0, 30, and 50% BWS. There was a good to excellent correlation between PCI and ECW in the observed walking conditions: in PG Pearson correlation was 0.919 (p<0.001; in CG Pearson correlation was 0.852 (p<0.001. In conclusion, the high significant correlations between PCI and ECW, in all the observed walking conditions, suggest that PCI is a valid outcome measure in subacute stroke patients.

  19. Concurrent validity of Physiological Cost Index in walking over ground and during robotic training in subacute stroke patients.

    Science.gov (United States)

    Delussu, Anna Sofia; Morone, Giovanni; Iosa, Marco; Bragoni, Maura; Paolucci, Stefano; Traballesi, Marco

    2014-01-01

    Physiological Cost Index (PCI) has been proposed to assess gait demand. The purpose of the study was to establish whether PCI is a valid indicator in subacute stroke patients of energy cost of walking in different walking conditions, that is, over ground and on the Gait Trainer (GT) with body weight support (BWS). The study tested if correlations exist between PCI and ECW, indicating validity of the measure and, by implication, validity of PCI. Six patients (patient group (PG)) with subacute stroke and 6 healthy age- and size-matched subjects as control group (CG) performed, in a random sequence in different days, walking tests overground and on the GT with 0, 30, and 50% BWS. There was a good to excellent correlation between PCI and ECW in the observed walking conditions: in PG Pearson correlation was 0.919 (p < 0.001); in CG Pearson correlation was 0.852 (p < 0.001). In conclusion, the high significant correlations between PCI and ECW, in all the observed walking conditions, suggest that PCI is a valid outcome measure in subacute stroke patients.

  20. Estimation of rank correlation for clustered data.

    Science.gov (United States)

    Rosner, Bernard; Glynn, Robert J

    2017-06-30

    It is well known that the sample correlation coefficient (R xy ) is the maximum likelihood estimator of the Pearson correlation (ρ xy ) for independent and identically distributed (i.i.d.) bivariate normal data. However, this is not true for ophthalmologic data where X (e.g., visual acuity) and Y (e.g., visual field) are available for each eye and there is positive intraclass correlation for both X and Y in fellow eyes. In this paper, we provide a regression-based approach for obtaining the maximum likelihood estimator of ρ xy for clustered data, which can be implemented using standard mixed effects model software. This method is also extended to allow for estimation of partial correlation by controlling both X and Y for a vector U_ of other covariates. In addition, these methods can be extended to allow for estimation of rank correlation for clustered data by (i) converting ranks of both X and Y to the probit scale, (ii) estimating the Pearson correlation between probit scores for X and Y, and (iii) using the relationship between Pearson and rank correlation for bivariate normally distributed data. The validity of the methods in finite-sized samples is supported by simulation studies. Finally, two examples from ophthalmology and analgesic abuse are used to illustrate the methods. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. An improved Pearson's correlation proximity-based hierarchical clustering for mining biological association between genes.

    Science.gov (United States)

    Booma, P M; Prabhakaran, S; Dhanalakshmi, R

    2014-01-01

    Microarray gene expression datasets has concerned great awareness among molecular biologist, statisticians, and computer scientists. Data mining that extracts the hidden and usual information from datasets fails to identify the most significant biological associations between genes. A search made with heuristic for standard biological process measures only the gene expression level, threshold, and response time. Heuristic search identifies and mines the best biological solution, but the association process was not efficiently addressed. To monitor higher rate of expression levels between genes, a hierarchical clustering model was proposed, where the biological association between genes is measured simultaneously using proximity measure of improved Pearson's correlation (PCPHC). Additionally, the Seed Augment algorithm adopts average linkage methods on rows and columns in order to expand a seed PCPHC model into a maximal global PCPHC (GL-PCPHC) model and to identify association between the clusters. Moreover, a GL-PCPHC applies pattern growing method to mine the PCPHC patterns. Compared to existing gene expression analysis, the PCPHC model achieves better performance. Experimental evaluations are conducted for GL-PCPHC model with standard benchmark gene expression datasets extracted from UCI repository and GenBank database in terms of execution time, size of pattern, significance level, biological association efficiency, and pattern quality.

  2. Remodeling Pearson's Correlation for Functional Brain Network Estimation and Autism Spectrum Disorder Identification

    Directory of Open Access Journals (Sweden)

    Weikai Li

    2017-08-01

    Full Text Available Functional brain network (FBN has been becoming an increasingly important way to model the statistical dependence among neural time courses of brain, and provides effective imaging biomarkers for diagnosis of some neurological or psychological disorders. Currently, Pearson's Correlation (PC is the simplest and most widely-used method in constructing FBNs. Despite its advantages in statistical meaning and calculated performance, the PC tends to result in a FBN with dense connections. Therefore, in practice, the PC-based FBN needs to be sparsified by removing weak (potential noisy connections. However, such a scheme depends on a hard-threshold without enough flexibility. Different from this traditional strategy, in this paper, we propose a new approach for estimating FBNs by remodeling PC as an optimization problem, which provides a way to incorporate biological/physical priors into the FBNs. In particular, we introduce an L1-norm regularizer into the optimization model for obtaining a sparse solution. Compared with the hard-threshold scheme, the proposed framework gives an elegant mathematical formulation for sparsifying PC-based networks. More importantly, it provides a platform to encode other biological/physical priors into the PC-based FBNs. To further illustrate the flexibility of the proposed method, we extend the model to a weighted counterpart for learning both sparse and scale-free networks, and then conduct experiments to identify autism spectrum disorders (ASD from normal controls (NC based on the constructed FBNs. Consequently, we achieved an 81.52% classification accuracy which outperforms the baseline and state-of-the-art methods.

  3. Remodeling Pearson's Correlation for Functional Brain Network Estimation and Autism Spectrum Disorder Identification.

    Science.gov (United States)

    Li, Weikai; Wang, Zhengxia; Zhang, Limei; Qiao, Lishan; Shen, Dinggang

    2017-01-01

    Functional brain network (FBN) has been becoming an increasingly important way to model the statistical dependence among neural time courses of brain, and provides effective imaging biomarkers for diagnosis of some neurological or psychological disorders. Currently, Pearson's Correlation (PC) is the simplest and most widely-used method in constructing FBNs. Despite its advantages in statistical meaning and calculated performance, the PC tends to result in a FBN with dense connections. Therefore, in practice, the PC-based FBN needs to be sparsified by removing weak (potential noisy) connections. However, such a scheme depends on a hard-threshold without enough flexibility. Different from this traditional strategy, in this paper, we propose a new approach for estimating FBNs by remodeling PC as an optimization problem, which provides a way to incorporate biological/physical priors into the FBNs. In particular, we introduce an L 1 -norm regularizer into the optimization model for obtaining a sparse solution. Compared with the hard-threshold scheme, the proposed framework gives an elegant mathematical formulation for sparsifying PC-based networks. More importantly, it provides a platform to encode other biological/physical priors into the PC-based FBNs. To further illustrate the flexibility of the proposed method, we extend the model to a weighted counterpart for learning both sparse and scale-free networks, and then conduct experiments to identify autism spectrum disorders (ASD) from normal controls (NC) based on the constructed FBNs. Consequently, we achieved an 81.52% classification accuracy which outperforms the baseline and state-of-the-art methods.

  4. Validation of Navigation Ultrasound for Clavicular Length Measurement

    DEFF Research Database (Denmark)

    Høj, Anders Thorsmark; Villa, Chiara; Christensen, Ole M.

    2017-01-01

    interval): approximately ± 7.5 mm, Pearson's correlation R: 0.948-0.974). Navigation ultrasound can measure clavicular length with an intra-rater reliability matching that of 3-D rendered computed tomography scans and with high validity. Its use could spread to other fields requiring accurate...... of 52.5 (range: 21-78 y) were included. Navigation ultrasound exhibited high reliability (intra-class correlation coefficient: 0.942-0.997, standard error of the mean: 0.7-2.9 mm, minimal detectable change: 2.3-8.1 mm) and validity (measurement error: 1.3%-1.8%, limits of agreement (95% confidence...

  5. Reconstructing gene regulatory networks from knock-out data using Gaussian Noise Model and Pearson Correlation Coefficient.

    Science.gov (United States)

    Mohamed Salleh, Faridah Hani; Arif, Shereena Mohd; Zainudin, Suhaila; Firdaus-Raih, Mohd

    2015-12-01

    A gene regulatory network (GRN) is a large and complex network consisting of interacting elements that, over time, affect each other's state. The dynamics of complex gene regulatory processes are difficult to understand using intuitive approaches alone. To overcome this problem, we propose an algorithm for inferring the regulatory interactions from knock-out data using a Gaussian model combines with Pearson Correlation Coefficient (PCC). There are several problems relating to GRN construction that have been outlined in this paper. We demonstrated the ability of our proposed method to (1) predict the presence of regulatory interactions between genes, (2) their directionality and (3) their states (activation or suppression). The algorithm was applied to network sizes of 10 and 50 genes from DREAM3 datasets and network sizes of 10 from DREAM4 datasets. The predicted networks were evaluated based on AUROC and AUPR. We discovered that high false positive values were generated by our GRN prediction methods because the indirect regulations have been wrongly predicted as true relationships. We achieved satisfactory results as the majority of sub-networks achieved AUROC values above 0.5. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Cross-cultural adaptation and validation of the Turkish version of Oxford hip score.

    Science.gov (United States)

    Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Hazar, Zeynep; Yüksel, İnci; Atilla, Bülent

    2015-06-01

    The purpose of this study was to translate the Oxford hip score (OHS) into Turkish and to evaluate the psychometric properties by testing the internal consistency, reproducibility, construct validity, and responsiveness in patients with hip osteoarthritis (OA). Oxford hip score was translated and culturally adapted according to the guidelines in the literature. Seventy patients (mean age 61.45 ± 9.29 years) with hip osteoarthritis participated in the study. Patients completed the Turkish Oxford hip score (OHS-TR), the Short-Form 36 (SF-36), and Western Ontario and McMaster Universities Index (WOMAC). Internal consistency was tested using Cronbach's α coefficient. Patients completed OHS-TR questionnaire twice in 7 days for determining the reproducibility. Correlation between the total results of both tests was determined by the Pearson correlation coefficient and intraclass correlation coefficient (ICC). Validity was assessed by calculating the Pearson correlation coefficient between the OHS-TR and WOMAC and SF-36 scores. Floor and ceiling effects were analyzed. The internal consistency was high (Cronbach's α 0.93). The construct validity showed a significant correlation between the OHS-TR and WOMAC and related SF-36 domains (p < 0.001). The ICC's ranged between 0.80 and 0.99. There was no floor or ceiling effect in total OHS-TR score. The OHS-TR questionnaire is valid, reliable, and responsive for the Turkish-speaking patients with hip OA.

  7. [Reliability and Validity of the Scale for Homophobia in Medicine Students].

    Science.gov (United States)

    Campo-Arias, Adalberto; Lafaurie, María Mercedes; Gaitán-Duarte, Hernando G

    2012-12-01

    There are several scales to quantify homophobia in different populations. However, the reliability and validity of these instruments among Colombian students are unknown. Consequently, this work is intended to assess reliability (inner consistency) as well as the validity of the Scale for Homophobia in Medicine students from a private university in Bogotá (Colombia). Methodological study with 199 Medicine students from 1st to 5th semester that filled out the Homophobia Scale form, the general welfare questionnaire, the Attitude Towards Gays and Lesbians Scale (ATGL), WHO-5 (divergent validity) and the Francis Scale of Attitude Toward Christianity (nomologic validity). Pearson's correlations were computed, the Cronbach's alfa coefficient, the omega coefficient (construct's reliability) and confirmatory factorial analysis. The Scale for Homophobia showed an alpha Cronbach coefficient of 0,785, an omega coefficient of 0,790 and a Pearson correlation with the ATGL of 0,844; with WHO-5, -0,059; and a Francis Scale of Attitude Toward Christianity, 0,187. The Scale toward Homophobia exhibited a relevant factor of 44,7% of the total variance. The Scale for Homophobia showed acceptable reliability and validity. New studies should investigate the stability of the scale and the nomologic validity regarding other constructs. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  8. Rating scales for dystonia in cerebral palsy: reliability and validity.

    Science.gov (United States)

    Monbaliu, E; Ortibus, E; Roelens, F; Desloovere, K; Deklerck, J; Prinzie, P; de Cock, P; Feys, H

    2010-06-01

    This study investigated the reliability and validity of the Barry-Albright Dystonia Scale (BADS), the Burke-Fahn-Marsden Movement Scale (BFMMS), and the Unified Dystonia Rating Scale (UDRS) in patients with bilateral dystonic cerebral palsy (CP). Three raters independently scored videotapes of 10 patients (five males, five females; mean age 13 y 3 mo, SD 5 y 2 mo, range 5-22 y). One patient each was classified at levels I-IV in the Gross Motor Function Classification System and six patients were classified at level V. Reliability was measured by (1) intraclass correlation coefficient (ICC) for interrater reliability, (2) standard error of measurement (SEM) and smallest detectable difference (SDD), and (3) Cronbach's alpha for internal consistency. Validity was assessed by Pearson's correlations among the three scales used and by content analysis. Moderate to good interrater reliability was found for total scores of the three scales (ICC: BADS=0.87; BFMMS=0.86; UDRS=0.79). However, many subitems showed low reliability, in particular for the UDRS. SEM and SDD were respectively 6.36% and 17.72% for the BADS, 9.88% and 27.39% for the BFMMS, and 8.89% and 24.63% for the UDRS. High internal consistency was found. Pearson's correlations were high. Content validity showed insufficient accordance with the new CP definition and classification. Our results support the internal consistency and concurrent validity of the scales; however, taking into consideration the limitations in reliability, including the large SDD values and the content validity, further research on methods of assessment of dystonia is warranted.

  9. A novel fractal image compression scheme with block classification and sorting based on Pearson's correlation coefficient.

    Science.gov (United States)

    Wang, Jianji; Zheng, Nanning

    2013-09-01

    Fractal image compression (FIC) is an image coding technology based on the local similarity of image structure. It is widely used in many fields such as image retrieval, image denoising, image authentication, and encryption. FIC, however, suffers from the high computational complexity in encoding. Although many schemes are published to speed up encoding, they do not easily satisfy the encoding time or the reconstructed image quality requirements. In this paper, a new FIC scheme is proposed based on the fact that the affine similarity between two blocks in FIC is equivalent to the absolute value of Pearson's correlation coefficient (APCC) between them. First, all blocks in the range and domain pools are chosen and classified using an APCC-based block classification method to increase the matching probability. Second, by sorting the domain blocks with respect to APCCs between these domain blocks and a preset block in each class, the matching domain block for a range block can be searched in the selected domain set in which these APCCs are closer to APCC between the range block and the preset block. Experimental results show that the proposed scheme can significantly speed up the encoding process in FIC while preserving the reconstructed image quality well.

  10. Karl Pearson and eugenics: personal opinions and scientific rigor.

    Science.gov (United States)

    Delzell, Darcie A P; Poliak, Cathy D

    2013-09-01

    The influence of personal opinions and biases on scientific conclusions is a threat to the advancement of knowledge. Expertise and experience does not render one immune to this temptation. In this work, one of the founding fathers of statistics, Karl Pearson, is used as an illustration of how even the most talented among us can produce misleading results when inferences are made without caution or reference to potential bias and other analysis limitations. A study performed by Pearson on British Jewish schoolchildren is examined in light of ethical and professional statistical practice. The methodology used and inferences made by Pearson and his coauthor are sometimes questionable and offer insight into how Pearson's support of eugenics and his own British nationalism could have potentially influenced his often careless and far-fetched inferences. A short background into Pearson's work and beliefs is provided, along with an in-depth examination of the authors' overall experimental design and statistical practices. In addition, portions of the study regarding intelligence and tuberculosis are discussed in more detail, along with historical reactions to their work.

  11. Validation of a semi-quantitative Food Frequency Questionnaire for Argentinean adults.

    Directory of Open Access Journals (Sweden)

    Mahshid Dehghan

    Full Text Available BACKGROUND: The Food Frequency Questionnaire (FFQ is the most commonly used method for ranking individuals based on long term food intake in large epidemiological studies. The validation of an FFQ for specific populations is essential as food consumption is culture dependent. The aim of this study was to develop a Semi-quantitative Food Frequency Questionnaire (SFFQ and evaluate its validity and reproducibility in estimating nutrient intake in urban and rural areas of Argentina. METHODS/PRINCIPAL FINDINGS: Overall, 256 participants in the Argentinean arm of the ongoing Prospective Urban and Rural Epidemiological study (PURE were enrolled for development and validation of the SFFQ. One hundred individuals participated in the SFFQ development. The other 156 individuals completed the SFFQs on two occasions, four 24-hour Dietary Recalls (24DRs in urban, and three 24DRs in rural areas during a one-year period. Correlation coefficients (r and de-attenuated correlation coefficients between 24DRs and SFFQ were calculated for macro and micro-nutrients. The level of agreement between the two methods was evaluated using classification into same and extreme quartiles and the Bland-Altman method. The reproducibility of the SFFQ was assessed by Pearson correlation coefficients and Intra-class Correlation Coefficients (ICC. The SFFQ consists of 96 food items. In both urban and rural settings de-attenuated correlations exceeded 0.4 for most of the nutrients. The classification into the same and adjacent quartiles was more than 70% for urban and 60% for rural settings. The Pearson correlation between two SFFQs varied from 0.30-0.56 and 0.32-0.60 in urban and rural settings, respectively. CONCLUSION: Our results showed that this SFFQ had moderate relative validity and reproducibility for macro and micronutrients in relation to the comparison method and can be used to rank individuals based on habitual nutrient intake.

  12. Karl pearson the scientific life in a statistical age

    CERN Document Server

    Porter, Theodore M

    2010-01-01

    Karl Pearson, founder of modern statistics, came to this field by way of passionate early studies of philosophy and cultural history as well as ether physics and graphical geometry. His faith in science grew out of a deeply moral quest, reflected also in his socialism and his efforts to find a new basis for relations between men and women. This biography recounts Pearson's extraordinary intellectual adventure and sheds new light on the inner life of science. Theodore Porter's intensely personal portrait of Pearson extends from religious crisis and sexual tensions to metaphysical and even m

  13. Reliability and Validity of the Temperament and Character Inventory

    Directory of Open Access Journals (Sweden)

    Mahboubeh Dadfar

    2010-10-01

    Full Text Available Objective: The Temperament and Character Inventory (TCI was developed to assess temperament including Novelty Seeking (NS, Harm Avoidance (HA, Reward Dependence (RD, Persistence (PS, and Character including Self-Directedness (SD, Cooperativeness (CO and Self Transcendence (ST dimensions of Cloninger's biopsychosocial model of personality in adults. The purpose of this study was to evaluate the reliability and validity of this inventory. Materials & Methods: In this validity test and standardization study, after translation of TCI into Farsi and back translation, the final form was prepared and administered to 220 students who were selected via simple sampling. Cronbach's alpha procedure and test-retest method was used to assess the reliability, and factor analysis of promax rotation was utilized to determine the validity of the inventory. Correlation of interscales and age with scales of TCI was calculated by Pearson correlation. A comparison of TCI scores between sex and also cross-cultural was down using independent t-test. Results: The alpha cofficients for the inventory ranged from 0.44 for the Persistence scale to 0.81 for the ST scale with a median 0f 0.68. The overall alpha cofficients for the whole inventory was 0.74. The Pearson correlation cofficient for the test-retest on 31 students after two months ranged from 0.53 for Novelty Seeking and Persistence to 0.82 for Harm Avoidance scales and from 0.24 for disorderliness vs regimentation (NS4 to 0.86 for fear of uncertainty vs self-confidene (HA2 subscales. The factor analysis showed six factors. Significant correlations were obtained between scales of Self–Directedness with Harm Avoidance (0.57, Self–Directedness with Cooperativeness (0.46. Conclusion: The current study confirms that Persian version of the Temperament and Character Inventory has satisfactory psychometric properties and acceptable reliability and validity for the use students of university population.

  14. Development and validation of the insulin treatment appraisal scale (ITAS) in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Snoek, Frank J; Skovlund, Søren E; Pouwer, Frans

    2007-01-01

    . Exploratory factor analysis (EFA), internal consistency (Cronbach's alpha) and item-total correlations were determined to test the reliability of the instrument. Concurrent validity was examined by calculating Pearson correlation coefficients between the different measures. Discriminant validity was examined...... 20-item scale was 0.89, suggesting high homogeneity and allowing for calculation of an overall score. Item-total correlations were in the range of 0.46-0.74 for the negative and 0.34 - 0.53 for the positive appraisal scale. The item pertaining to weight gain, as part of the negative appraisal...... subscale, showed low communality and deserves further testing. Concurrent validity was confirmed with low to moderate correlations in the expected direction between ITAS and WHO-5 and PAID. Discriminant validity was confirmed by the fact that patients using insulin had significantly less negative...

  15. Development and validation of modified disease activity scores in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Baker, Joshua F; Conaghan, Philip G; Smolen, Josef S

    2014-01-01

    -CDAI) were generated for each subject in the validation cohort. The M-DAS28, M-SDAI, and M-CDAI scores were compared to conventional scores of disease activity with regard to associations with MRI measures of synovitis and radiographic progression, assessed using Pearson's and Spearman's correlations, linear......OBJECTIVE: To develop and validate composite disease activity scores, based on widely available clinical measures, that would demonstrate improved correlation with detection of synovitis on magnetic resonance imaging (MRI) and radiographic progression, in comparison with conventional measures.......15 × SJC28 + 0.22 × EvGA + 1 and M-SDAI = CRP + SJC28 + EvGA. Both modified and conventional disease activity scores correlated significantly with MRI measures of synovitis. Modified scores showed superior correlation with synovitis, as compared to conventional scores, at all time points (P

  16. Systematic bias of correlation coefficient may explain negative accuracy of genomic prediction.

    Science.gov (United States)

    Zhou, Yao; Vales, M Isabel; Wang, Aoxue; Zhang, Zhiwu

    2017-09-01

    Accuracy of genomic prediction is commonly calculated as the Pearson correlation coefficient between the predicted and observed phenotypes in the inference population by using cross-validation analysis. More frequently than expected, significant negative accuracies of genomic prediction have been reported in genomic selection studies. These negative values are surprising, given that the minimum value for prediction accuracy should hover around zero when randomly permuted data sets are analyzed. We reviewed the two common approaches for calculating the Pearson correlation and hypothesized that these negative accuracy values reflect potential bias owing to artifacts caused by the mathematical formulas used to calculate prediction accuracy. The first approach, Instant accuracy, calculates correlations for each fold and reports prediction accuracy as the mean of correlations across fold. The other approach, Hold accuracy, predicts all phenotypes in all fold and calculates correlation between the observed and predicted phenotypes at the end of the cross-validation process. Using simulated and real data, we demonstrated that our hypothesis is true. Both approaches are biased downward under certain conditions. The biases become larger when more fold are employed and when the expected accuracy is low. The bias of Instant accuracy can be corrected using a modified formula. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Validation of a short, qualitative food frequency questionnaire in French adults participating in the MONA LISA-NUT study 2005-2007.

    Science.gov (United States)

    Giovannelli, Jonathan; Dallongeville, Jean; Wagner, Aline; Bongard, Vanina; Laillet, Brigitte; Marecaux, Nadine; Ruidavets, Jean Bernard; Haas, Bernadette; Ferrieres, Jean; Arveiler, Dominique; Simon, Chantal; Dauchet, Luc

    2014-04-01

    Food frequency questionnaires (FFQs) are often used to evaluate individuals' food intakes in epidemiologic studies because of their simplicity and low cost. To assess the validity of a short (24 items), qualitative FFQ used in the MONA LISA-NUT study. Cross-sectional study of a representative sample in three French counties. The sample included 2,630 participants aged 35 to 65 years from the MONA LISA-NUT study. Food consumption was measured with the FFQ and via food records for 3 consecutive days. Plasma fatty acids were measured from a subset of participants. The FFQ items' validity was assessed by calculating crude and deattenuated Pearson correlation coefficients between frequencies reported by the FFQ and average weights reported by the food records. Furthermore, the validity of some items of the FFQ measuring the consumption of fatty foods was assessed by calculating Pearson correlation coefficients between frequencies of consumption of these foods and dosages of the corresponding plasma fatty acids: fish and eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), olive oil and oleic acid, margarine and elaidic acid, and dairy products and pentadecanoic and heptadecanoic acids. The mean of the deattenuated Pearson correlation coefficients for all items was 0.46, with values ranging from 0.22 (fried food) to 0.77 (breakfast cereal). The correlation coefficient was ≤ 0.4 for one third of the 24 items. Moderate correlations were found between fish and EPA/DHA (EPA: r=0.43, 95% CI 0.33 to 0.51; DHA: r=0.39, 95% CI 0.30 to 0.47), but not for other food items. One third of the 24 items in the short, qualitative FFQ evaluated here were not sufficiently valid. However, for the food groups most commonly studied in the literature, this FFQ had the same degree of validity as other questionnaires designed to classify subjects according to their level of intake. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  18. Interview with Mike Parker Pearson

    Directory of Open Access Journals (Sweden)

    Thomas J. T. Williams

    2013-02-01

    Full Text Available Mike Parker Pearson is the Institute of Archaeology’s newly appointed Professor of British Later Prehistory. In this interview he reflects on his experience at the birth of post-processualism, current problems and opportunities in modern archaeology, and the subject for which he is best known: Stonehenge.

  19. Creation and Validation of the Self-esteem/Self-image Female Sexuality (SESIFS) Questionnaire

    OpenAIRE

    Lordello, Maria CO; Ambrogini, Carolina C; Fanganiello, Ana L; Embiru?u, Teresa R; Zaneti, Marina M; Veloso, Laise; Piccirillo, Livia B; Crude, Bianca L; Haidar, Mauro; Silva, Ivaldo

    2014-01-01

    Introduction Self-esteem and self-image are psychological aspects that affect sexual function. AIMS To validate a new measurement tool that correlates the concepts of self-esteem, self-image, and sexuality. Methods A 20-question test (the self-esteem/self-image female sexuality [SESIFS] questionnaire) was created and tested on 208 women. Participants answered: Rosenberg's self-esteem scale, the female sexual quotient (FSQ), and the SESIFS questionnaire. Pearson's correlation coefficient was u...

  20. Relative validity of a food frequency questionnaire to identify dietary patterns in an adult Mexican population.

    Science.gov (United States)

    Denova-Gutiérrez, Edgar; Tucker, Katherine L; Salmerón, Jorge; Flores, Mario; Barquera, Simón

    2016-01-01

    To examine the validity of a semi-quantitative food frequency questionnaire (SFFQ) to identify dietary patterns in an adult Mexican population. A 140-item SFFQ and two 24-hour dietary recalls (24DRs) were administered. Foods were categorized into 29 food groups used to derive dietary patterns via factor analysis. Pearson and intraclass correlations coefficients between dietary pattern scores identified from the SFFQ and 24DRs were assessed. Pattern 1 was high in snacks, fast food, soft drinks, processed meats and refined grains; pattern 2 was high in fresh vegetables, fresh fruits, and dairy products; and pattern 3 was high in legumes, eggs, sweetened foods and sugars. Pearson correlation coefficients between the SFFQ and the 24DRs for these patterns were 0.66 (P<0.001), 0.41 (P<0.001) and 0.29 (P=0.193) respectively. Our data indicate reasonable validity of the SFFQ, using factor analysis, to derive major dietary patterns in comparison with two 24DR.

  1. Online Radiology Reporting with Peer Review as a Learning and Feedback Tool in Radiology; Implementation, Validity, and Student Impressions

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Shen, Nicholas W; Nielsen, Dorte Hald

    2017-01-01

    for student-generated radiological reports were compared to scores obtained in the summative multiple choice (MCQ) examination for the course. Student satisfaction was measured using a bespoke questionnaire. There was a weak positive correlation (Pearson correlation coefficient = 0.32, p ... scores awarded by the students and the scores they obtained in the MCQ examination (Pearson correlation coefficient = 0.17, p = 0.14). In conclusion, we have created a realistic radiology imaging exercise with readily available software. The peer review scores are valid in that to a limited degree...... review scores students received and the student scores obtained in the MCQ examination. The difference in peer review scores received by students grouped according to their level of course performance (high vs. low) was statistically significant (p correlation was found between peer review...

  2. Validity and reliability of Preschool Language Scale 4 for measuring language development in children 48-59 months of age

    Directory of Open Access Journals (Sweden)

    Nuryani Sidarta

    2016-04-01

    Full Text Available Prevalence rates for speech and language delay have been reported across wide ranges. Speech and language delay affects 5% to 8% of preschool children, often persisting into the school years.  A cross-sectional study was conducted in 208 children aged 48-59 months to determine the validity and reliability of the Indonesian edition of the Preschool Language Scale version 4 (PLS4 as a screening tool for the identification of language development disorders. Construct validity was examined by using Pearson correlation coefficient. Internal consistency was tested and repeated measurements were taken to establish the stability coefficient and intraclass correlation coefficients (ICC for test-retest reliability. For construct validity, the Pearson correlation coefficient ranged from 0.151-0.526, indicating that all questions in this instrument were valid for measuring auditory comprehension (AC and expressive communication skills (EC. Cronbach’s alpha level ranged from 0.81-0.95 with standard error of measurement (SEM ranging from 3.1-3.3. Stability coefficients ranged from 0.98-.0.99 with ICC coefficient ranging from 0.97-0.99 both of which showed an excellent reliability. This study found that PLS-4 is a valid and reliable instrument. It is easy to handle and can be recommended for assessing language development in children aged 48-59 months.

  3. The Korean Version of the Cognitive Assessment Scale for Stroke Patients (K-CASP): A Reliability and Validity Study.

    Science.gov (United States)

    Park, Kwon-Hee; Lee, Hee-Won; Park, Kee-Boem; Lee, Jin-Youn; Cho, Ah-Ra; Oh, Hyun-Mi; Park, Joo Hyun

    2017-06-01

    To develop the Korean version of the Cognitive Assessment Scale for Stroke Patients (K-CASP) and to evaluate the test reliability and validity of the K-CASP in stroke patients. The original CASP was translated into Korean, back-translated into English, then reviewed and compared with the original version. Thirty-three stroke patients were assessed independently by two examiners using the K-CASP twice, with a one-day interval, for a total of four test results. To evaluate the reliability of the K-CASP, intra-class correlation coefficients were used. Pearson correlations were calculated and simple regression analyses performed with the Korean version of Mini-Mental State Examination (K-MMSE) and the aphasia quotient (AQ) to assess the validity. The mean score was 24.42±9.47 (total score 36) for the K-CASP and 21.50±7.01 (total score 30) for the K-MMSE. The inter-rater correlation coefficients of the K-CASP were 0.992 on the first day and 0.995 on the second day. The intra-rater correlation coefficients of the K-CASP were 0.997 for examiner 1 and 0.996 for examiner 2. In the Pearson correlation analysis, the K-CASP score significantly correlated with the K-MMSE score (r=0.825, preliable and valid instrument for cognitive dysfunction screening in post-stroke patients. It is more applicable than other cognitive assessment tools in stroke patients with aphasia.

  4. Validation and cultural adaptation of a German version of the Physicians' Reactions to Uncertainty scales

    Directory of Open Access Journals (Sweden)

    Joest Katharina

    2007-06-01

    Full Text Available Abstract Background The aim of the study was to examine the validity of a translated and culturally adapted version of the Physicians' Reaction to Uncertainty scales (PRU in primary care physicians. Methods In a structured process, the original questionnaire was translated, culturally adapted and assessed after administering it to 93 GPs. Test-retest reliability was tested by sending the questionnaire to the GPs again after two weeks. Results The principal factor analysis confirmed the postulated four-factor structure underlying the 15 items. In contrast to the original version, item 5 achieved a higher loading on the 'concern about bad outcomes' scale. Consequently, we rearranged the scales. Good item-scale correlations were obtained, with Pearson's correlation coefficient ranging from 0.56–0.84. As regards the item-discriminant validity between the scales 'anxiety due to uncertainty' and 'concern about bad outcomes', partially high correlations (Pearson's correlation coefficient 0.02–0.69; p Conclusion Dealing with uncertainty is an important issue in daily practice. The psychometric properties of the rearranged German version of the PRU are satisfying. The revealed floor effects do not limit the significance of the questionnaire. Thus, the German version of the PRU could contribute to the further evaluation of the impact of uncertainty in primary care physicians.

  5. Validation of a quantitative Eimeria spp. PCR for fresh droppings of broiler chickens.

    Science.gov (United States)

    Peek, H W; Ter Veen, C; Dijkman, R; Landman, W J M

    2017-12-01

    A quantitative Polymerase Chain Reaction (qPCR) for the seven chicken Eimeria spp. was modified and validated for direct use on fresh droppings. The analytical specificity of the qPCR on droppings was 100%. Its analytical sensitivity (non-sporulated oocysts/g droppings) was 41 for E. acervulina, ≤2900 for E. brunetti, 710 for E. praecox, 1500 for E. necatrix, 190 for E. tenella, 640 for E. maxima, and 1100 for E. mitis. Field validation of the qPCR was done using droppings with non-sporulated oocysts from 19 broiler flocks. To reduce the number of qPCR tests five grams of each pooled sample (consisting of ten fresh droppings) per time point were blended into one mixed sample. Comparison of the oocysts per gram (OPG)-counting method with the qPCR using pooled samples (n = 1180) yielded a Pearson's correlation coefficient of 0.78 (95% CI: 0.76-0.80) and a Pearson's correlation coefficient of 0.76 (95% CI: 0.70-0.81) using mixed samples (n = 236). Comparison of the average of the OPG-counts of the five pooled samples with the mixed sample per time point (n = 236) showed a Pearson's correlation coefficient (R) of 0.94 (95% CI: 0.92-0.95) for the OPG-counting method and 0.87 (95% CI: 0.84-0.90) for the qPCR. This indicates that mixed samples are practically equivalent to the mean of five pooled samples. The good correlation between the OPG-counting method and the qPCR was further confirmed by the visual agreement between the total oocyst/g shedding patterns measured with both techniques in the 19 broiler flocks using the mixed samples.

  6. The validity of the 4-Skills Scan: A double validation study.

    Science.gov (United States)

    van Kernebeek, W G; de Kroon, M L A; Savelsbergh, G J P; Toussaint, H M

    2018-06-01

    Adequate gross motor skills are an essential aspect of a child's healthy development. Where physical education (PE) is part of the primary school curriculum, a strong curriculum-based emphasis on evaluation and support of motor skill development in PE is apparent. Monitoring motor development is then a task for the PE teacher. In order to fulfil this task, teachers need adequate tools. The 4-Skills Scan is a quick and easily manageable gross motor skill instrument; however, its validity has never been assessed. Therefore, the purpose of this study is to assess the construct and concurrent validity of both 4-Skills Scans (version 2007 and version 2015). A total of 212 primary school children (6 - 12 years old), was requested to participate in both versions of the 4-Skills Scan. For assessing construct validity, children covered an obstacle course with video recordings for observation by an expert panel. For concurrent validity, a comparison was made with the MABC-2, by calculating Pearson correlations. Multivariable linear regression analyses were performed to determine the contribution of each subscale to the construct of gross motor skills, according to the MABC-2 and the expert panel. Correlations between the 4-Skills Scans and expert valuations were moderate, with coefficients of .47 (version 2007) and .46 (version 2015). Correlations between the 4-Skills Scans and the MABC-2 (gross) were moderate (.56) for version 2007 and high (.64) for version 2015. It is concluded that both versions of the 4-Skills Scans are satisfactory valid instruments for assessing gross motor skills during PE lessons. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Spanish validation of Bad Sobernheim Stress Questionnaire (BSSQ (brace).es) for adolescents with braces.

    Science.gov (United States)

    D'Agata, Elisabetta; Testor, Carles Pérez; Rigo, Manuel

    2010-07-15

    As a result of scientific and medical professionals gaining interest in Stress and Health Related Quality of Life (HRQL), the aim of our research is, thus, to validate into Spanish the German questionnaire Bad Sobernheim Stress Questionnaire (BSSQ) (mit Korsett), for adolescents wearing braces. The methodology used adheres to literature on trans-cultural adaptation by doing a translation and a back translation; it involved 35 adolescents, ages ranging between 10 and 16, with Adolescent Idiopathic Scoliosis (AIS) and wearing the same kind of brace (Rigo System Chêneau Brace). The materials used were a socio-demographics data questionnaire, the SRS-22 and the Spanish version of BSSQ(brace).es. The statistical analysis calculated the reliability (test-retest reliability and internal consistency) and the validity (convergent and construct validity) of the BSSQ (brace).es. BSSQ(brace).es is reliable because of its satisfactory internal consistency (Cronbach's alpha coefficient was 0.809, p < 0.001) and temporal stability (test-retest method with a Pearson correlation coefficient of 0.902 (p < 0.01)).It demonstrated convergent validity with SRS-22 since the Pearson correlation coefficient was 0.656 (p < 0.01). By undertaking an Exploratory Principal Components Analysis, a latent structure was found based on two Components which explicate the variance at 60.8%. BSSQ (brace).es is reliable and valid and can be used with Spanish adolescents to assess the stress level caused by the brace.

  8. Validity and reproducibility of a Spanish dietary history.

    Directory of Open Access Journals (Sweden)

    Pilar Guallar-Castillón

    Full Text Available To assess the validity and reproducibility of food and nutrient intake estimated with the electronic diet history of ENRICA (DH-E, which collects information on numerous aspects of the Spanish diet.The validity of food and nutrient intake was estimated using Pearson correlation coefficients between the DH-E and the mean of seven 24-hour recalls collected every 2 months over the previous year. The reproducibility was estimated using intraclass correlation coefficients between two DH-E made one year apart.The correlations coefficients between the DH-E and the mean of seven 24-hour recalls for the main food groups were cereals (r = 0.66, meat (r = 0.66, fish (r = 0.42, vegetables (r = 0.62 and fruits (r = 0.44. The mean correlation coefficient for all 15 food groups considered was 0.53. The correlations for macronutrients were: energy (r = 0.76, proteins (r= 0.58, lipids (r = 0.73, saturated fat (r = 0.73, monounsaturated fat (r = 0.59, polyunsaturated fat (r = 0.57, and carbohydrates (r = 0.66. The mean correlation coefficient for all 41 nutrients studied was 0.55. The intraclass correlation coefficient between the two DH-E was greater than 0.40 for most foods and nutrients.The DH-E shows good validity and reproducibility for estimating usual intake of foods and nutrients.

  9. Validation of the Spanish version of the WOMAC questionnaire for patients with hip or knee osteoarthritis. Western Ontario and McMaster Universities Osteoarthritis Index.

    Science.gov (United States)

    Escobar, A; Quintana, J M; Bilbao, A; Azkárate, J; Güenaga, J I

    2002-11-01

    The aim of this study was to validate a translated version of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) questionnaire in Spanish patients with hip or knee osteoarthritis (OA). The WOMAC questionnaire and the SF-36 were administered to a sample of 269 patients on the waiting list for hip or knee replacement. We studied the convergent validity and the item-scale correlation using Pearson's correlation coefficient and Spearman's pi. For the reliability study we used another sample of 58 patients who received the WOMAC twice within 15 days. The Pearson's, Spearman's pi, and intraclass correlation coefficients were calculated. Internal consistency was measured by Cronbach's alpha. The responsiveness study was carried out by resending the two questionnaires to all patients 6 months after surgical intervention; responsiveness was measured by means of the paired t-test, the effect size I and the standardised response mean. The Pearson's coefficients for the convergent validity ranged from -0.52 to -0.63. The coefficients obtained for the item-scale correlation of the pain area were 0.74 or higher, 0.91 or higher for stiffness, and 0.61 or higher for function. When measuring the test-retest reliability, the coefficients ranged from 0.66 to 0.81. Internal consistency yielded a Cronbach's alpha ranging from 0.81 to 0.93. The responsiveness showed an effect size I ranging from 1.5 to 2.2 in patients who underwent hip replacement; for those who underwent knee replacement the range was 1 to 1.8. The standardised response mean ranged from 1.3 to 1.9 for patients with hip OA; those with knee OA ranged from 0.8 to 1.5. The Spanish version of WOMAC is a valid, reliable and responsive instrument in patients with hip or knee OA.

  10. Relative validity of a food frequency questionnaire to identify dietary patterns in an adult Mexican population

    Directory of Open Access Journals (Sweden)

    Edgar Denova-Gutiérrez

    2016-12-01

    Full Text Available Objective. To examine the validity of a semi-quantitative food frequency questionnaire (SFFQ to identify dietary patterns in an adult Mexican population. Materials and methods. A 140-item SFFQ and two 24-hour dietary recalls (24DRs were administered. Foods were categorized into 29 food groups used to derive dietary patterns via factor analy­sis. Pearson and intraclass correlations coefficients between dietary pattern scores identified from the SFFQ and 24DRs were assessed. Results. Pattern 1 was high in snacks, fast food, soft drinks, processed meats and refined grains; pattern 2 was high in fresh vegetables, fresh fruits, and dairy products; and pattern 3 was high in legumes, eggs, sweetened foods and sugars. Pearson correlation oefficients between the SFFQ and the 24DRs for these patterns were 0.66 (P<0.001, 0.41 (P<0.001 and 0.29 (P=0.193 respectively. Conclusions. Our data indicate reasonable validity of the SFFQ, using fac­tor analysis, to derive major dietary patterns in comparison with two 24DR.

  11. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  12. Correlation Revelation: The Search for Meaning in Pearson's Coefficient

    Science.gov (United States)

    Huhn, Craig

    2016-01-01

    When the author was first charged with getting a group of students to understand the correlation coefficient, he did not anticipate the topic would challenge his own understanding, let alone cause him to eventually question the very nature of mathematics itself. On the surface, the idea seemed straightforward, one that millions of students across…

  13. Principal components in the discrimination of outliers: A study in simulation sample data corrected by Pearson's and Yates´s chi-square distance

    Directory of Open Access Journals (Sweden)

    Manoel Vitor de Souza Veloso

    2016-04-01

    Full Text Available Current study employs Monte Carlo simulation in the building of a significance test to indicate the principal components that best discriminate against outliers. Different sample sizes were generated by multivariate normal distribution with different numbers of variables and correlation structures. Corrections by chi-square distance of Pearson´s and Yates's were provided for each sample size. Pearson´s correlation test showed the best performance. By increasing the number of variables, significance probabilities in favor of hypothesis H0 were reduced. So that the proposed method could be illustrated, a multivariate time series was applied with regard to sales volume rates in the state of Minas Gerais, obtained in different market segments.

  14. Adaptation and Assessment of Reliability and Validity of the Greek Version of the Ohkuma Questionnaire for Dysphagia Screening

    Science.gov (United States)

    Papadopoulou, Soultana L.; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam

    2016-01-01

    Introduction The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements (p = 0.02 and p = 0.016). Conclusion The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients. PMID:28050209

  15. Fast computation of voxel-level brain connectivity maps from resting-state functional MRI using l₁-norm as approximation of Pearson's temporal correlation: proof-of-concept and example vector hardware implementation.

    Science.gov (United States)

    Minati, Ludovico; Zacà, Domenico; D'Incerti, Ludovico; Jovicich, Jorge

    2014-09-01

    An outstanding issue in graph-based analysis of resting-state functional MRI is choice of network nodes. Individual consideration of entire brain voxels may represent a less biased approach than parcellating the cortex according to pre-determined atlases, but entails establishing connectedness for 1(9)-1(11) links, with often prohibitive computational cost. Using a representative Human Connectome Project dataset, we show that, following appropriate time-series normalization, it may be possible to accelerate connectivity determination replacing Pearson correlation with l1-norm. Even though the adjacency matrices derived from correlation coefficients and l1-norms are not identical, their similarity is high. Further, we describe and provide in full an example vector hardware implementation of l1-norm on an array of 4096 zero instruction-set processors. Calculation times correlation in very high-density resting-state functional connectivity analyses. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. [Calculating Pearson residual in logistic regressions: a comparison between SPSS and SAS].

    Science.gov (United States)

    Xu, Hao; Zhang, Tao; Li, Xiao-song; Liu, Yuan-yuan

    2015-01-01

    To compare the results of Pearson residual calculations in logistic regression models using SPSS and SAS. We reviewed Pearson residual calculation methods, and used two sets of data to test logistic models constructed by SPSS and STATA. One model contained a small number of covariates compared to the number of observed. The other contained a similar number of covariates as the number of observed. The two software packages produced similar Pearson residual estimates when the models contained a similar number of covariates as the number of observed, but the results differed when the number of observed was much greater than the number of covariates. The two software packages produce different results of Pearson residuals, especially when the models contain a small number of covariates. Further studies are warranted.

  17. THE ROWWISE CORRELATION BETWEEN 2 PROXIMITY MATRICES AND THE PARTIAL ROWWISE CORRELATION

    NARCIS (Netherlands)

    de Vries, Han

    This paper discusses rowwise matrix correlation, based on the weighted sum of correlations between all pairs of corresponding rows of two proximity matrices, which may both be square (symmetric or asymmetric) or rectangular. Using the correlation coefficients usually associated with Pearson,

  18. Developing and Evaluating Validity and Reliability of Persian Version of “Dichotic Fused Rhymed Word Test”

    Directory of Open Access Journals (Sweden)

    Nasrin Ghanbari

    2015-10-01

    Full Text Available Objective: The aim of the present study is to develope and evaluate validity and reliability of Persian version of Dichotic Fused Rhymed Words Test in 18-25 years old normal population. Materials & Methods: The Persian version of Dichotic Fused Rhymed Words Test consisted of 15 pairs of monosyllable rhymed words. These paired words are set in 4 lists of 30 items that simultaneously were presented one to the left and another to the right ear so that they lead to perception of a single fusion concept. After selecting the test material from Moin Persian dictionary according to the intended criteria and pairing the rhymed words, content validity was assessed through lawshe method by 10 expert persons, words with high validity were selected and lists were set. Then, the words of each list were recorded on CD in a dichotic mode. Thereafter, the study was performed in 124 normal individuals (68 females and 56 males within ages ranging from 18 to 25 years and the scores were recorded on a designed scoring form. To examine reliability of test, the test was performed on 15 individuals again two weeks after the initial test and the Pearson correlation was assessed. Results: There are significant differences between mean scores of right and left ears (P<0.001. Content Validity Ratio was 0.8-1 for every item. Pearson correlation was 0.83 for test-retest (P<0.001. Cronbach’s alpha and Intra Class Correlation (ICC was 0.81 and 0.84 for internal correlation between scores of lists of test. The result showed that there is significant correlation between the lists. Conclusion: Based on the obtained results, the Persian version of Dichotic Fused Rhymed Words Test has a good content validity and reliability. It can be used in detecting function of corpus callosum, lateralization of the cerebral hemispheres and assessment of central auditory processing.

  19. The City of Hope-Quality of Life-Ostomy Questionnaire: Persian Translation and Validation

    OpenAIRE

    Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M

    2014-01-01

    Background: Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. Aim: This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). Subjects and Methods: This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's c...

  20. Correlation Coefficients: Appropriate Use and Interpretation.

    Science.gov (United States)

    Schober, Patrick; Boer, Christa; Schwarte, Lothar A

    2018-05-01

    Correlation in the broadest sense is a measure of an association between variables. In correlated data, the change in the magnitude of 1 variable is associated with a change in the magnitude of another variable, either in the same (positive correlation) or in the opposite (negative correlation) direction. Most often, the term correlation is used in the context of a linear relationship between 2 continuous variables and expressed as Pearson product-moment correlation. The Pearson correlation coefficient is typically used for jointly normally distributed data (data that follow a bivariate normal distribution). For nonnormally distributed continuous data, for ordinal data, or for data with relevant outliers, a Spearman rank correlation can be used as a measure of a monotonic association. Both correlation coefficients are scaled such that they range from -1 to +1, where 0 indicates that there is no linear or monotonic association, and the relationship gets stronger and ultimately approaches a straight line (Pearson correlation) or a constantly increasing or decreasing curve (Spearman correlation) as the coefficient approaches an absolute value of 1. Hypothesis tests and confidence intervals can be used to address the statistical significance of the results and to estimate the strength of the relationship in the population from which the data were sampled. The aim of this tutorial is to guide researchers and clinicians in the appropriate use and interpretation of correlation coefficients.

  1. The Female Sexual Function Index (FSFI): linguistic validation of the Italian version.

    Science.gov (United States)

    Filocamo, Maria Teresa; Serati, Maurizio; Li Marzi, Vincenzo; Costantini, Elisabetta; Milanesi, Martina; Pietropaolo, Amelia; Polledro, Patrizio; Gentile, Barbara; Maruccia, Serena; Fornia, Samanta; Lauri, Irene; Alei, Rosanna; Arcangeli, Paola; Sighinolfi, Maria Chiara; Manassero, Francesca; Andretta, Elena; Palazzetti, Anna; Bertelli, Elena; Del Popolo, Giulio; Villari, Donata

    2014-02-01

    Although several new measurements for female sexual dysfunction (FSD) have recently been developed, the Female Sexual Function Index (FSFI) remains the gold standard for screening and one of the most widely used questionnaires. The Italian translation of the FSFI has been used in several studies conducted in Italy, but a linguistic validation of the Italian version does not exist. The aim of this study was to perform a linguistic validation of the Italian version of the FSFI. A multicenter cross-sectional study conducted in 14 urological and gynecological clinics, uniformly distributed over Italian territory. We performed all steps necessary to determine the reliability and the test-retest reliability of the Italian version of the FSFI. The study population was a convenience sample of 409 Italian women. The reliability of the questionnaire was calculated using Cronbach's alpha, which was considered weak, moderate, or high if its value was found less than 0.6, between 0.6 and 0.8, or equal to or greater than 0.8, respectively. The test-retest reliability was assessed for all women in the sample by calculating Pearson's concordance correlation coefficient for each domain and for the total score, both at baseline and after 15 days (r range between -1.00 to +1.00, where +1.00 indicates the strongest positive association). Cronbach's alpha coefficients for total and domain score were sufficiently high, ranging from 0.92 to 0.97 for the total sample. The test-retest procedure revealed that the concordance correlation coefficient was very high both for FSFI-I total score (Pearson's P = 0.93) and for each domain (Pearson's P always >0.92). For the first time in the literature, our study has produced a validated and reliable Italian version of the FSFI questionnaire. Consequently, the Italian FSFI can be used as a reliable tool for preliminary screening for female sexual dysfunction for Italian women. © 2013 International Society for Sexual Medicine.

  2. An SPSS Macro to Compute Confidence Intervals for Pearson’s Correlation

    Directory of Open Access Journals (Sweden)

    Bruce Weaver

    2014-04-01

    Full Text Available In many disciplines, including psychology, medical research, epidemiology and public health, authors are required, or at least encouraged to report confidence intervals (CIs along with effect size estimates. Many students and researchers in these areas use IBM-SPSS for statistical analysis. Unfortunately, the CORRELATIONS procedure in SPSS does not provide CIs in the output. Various work-around solutions have been suggested for obtaining CIs for rhowith SPSS, but most of them have been sub-optimal. Since release 18, it has been possible to compute bootstrap CIs, but only if users have the optional bootstrap module. The !rhoCI macro described in this article is accessible to all SPSS users with release 14 or later. It directs output from the CORRELATIONS procedure to another dataset, restructures that dataset to have one row per correlation, computes a CI for each correlation, and displays the results in a single table. Because the macro uses the CORRELATIONS procedure, it allows users to specify a list of two or more variables to include in the correlation matrix, to choose a confidence level, and to select either listwise or pairwise deletion. Thus, it offers substantial improvements over previous solutions to theproblem of how to compute CIs for rho with SPSS.

  3. Development of the Italian version of the Oswestry Disability Index (ODI-I): A cross-cultural adaptation, reliability, and validity study.

    Science.gov (United States)

    Monticone, Marco; Baiardi, Paola; Ferrari, Silvano; Foti, Calogero; Mugnai, Raffaele; Pillastrini, Paolo; Vanti, Carla; Zanoli, Gustavo

    2009-09-01

    Evaluation of the psychometric properties of a translated, culturally adapted questionnaire. Translating, culturally adapting, and validating the Italian version of the Oswestry Disability Index (ODI-I), allowing its use in Italian-speaking patients with low back pain inside and outside Italy. Growing attention is devoted to standardized outcome measures to improve interventions for low back pain. A translated form of the ODI in patients with low back pain has never been validated within the Italian population. The ODI-I questionnaire was developed involving forward-backward translation, final review by an expert committee and test of the prefinal version to establish as better as possible proper correspondence with the original English latest version (2.1a). Psychometric testing included factor analysis, reliability by internal consistency (Cronbach alpha) and test-retest repeatability (Intraclass Coefficient Correlation), concurrent validity by comparing the ODI-I to Visual Analogue Scale, (Pearson correlation), and construct validity by comparing the ODI-I to Roland Morris Disability Questionnaire, RMDQ, and to Short Form Health Survey, Short Form Health Survey-36 (Pearson correlation). The authors required a 3-month period before achieving a shared version of the ODI-I. The questionnaire was administered to 126 subjects, showing satisfying acceptability. Factor analysis demonstrated a 1-factor structure (45% of explained variance). The questionnaire showed high internal consistency (alpha = 0.855) and good test-retest reliability (ICC = 0.961). Concurrent validity was confirmed by a high correlation with Visual Analogue Scale (r = 0.73, P < 0.001), Construct validity revealed high correlations with RMDQ (r = 0.819, P < 0.001), and with Short Form Health Survey-36 domains, highly significant with the exception of Mental Health (r = -0.139, P = 0.126). The ODI outcome measure was successfully translated into Italian, showing good factorial structure and

  4. Creation and Validation of the Self-esteem/Self-image Female Sexuality (SESIFS) Questionnaire.

    Science.gov (United States)

    Lordello, Maria Co; Ambrogini, Carolina C; Fanganiello, Ana L; Embiruçu, Teresa R; Zaneti, Marina M; Veloso, Laise; Piccirillo, Livia B; Crude, Bianca L; Haidar, Mauro; Silva, Ivaldo

    2014-01-01

    Self-esteem and self-image are psychological aspects that affect sexual function. To validate a new measurement tool that correlates the concepts of self-esteem, self-image, and sexuality. A 20-question test (the self-esteem/self-image female sexuality [SESIFS] questionnaire) was created and tested on 208 women. Participants answered: Rosenberg's self-esteem scale, the female sexual quotient (FSQ), and the SESIFS questionnaire. Pearson's correlation coefficient was used to test concurrent validity of the SESIFS against Rosenberg's self-esteem scale and the FSQ. Reliability was tested using the Cronbach's alpha coefficient. The new questionnaire had a good overall reliability (Cronbach's alpha r = 0.862, p self-esteem domain r = 0.32, p self-esteem, self-image, and sexuality domains. A new, revised version is being tested and will be presented in an upcoming publication.

  5. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Directory of Open Access Journals (Sweden)

    Munmun Koley

    2014-10-01

    Full Text Available A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H, Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items and patient care indicators (5 items. Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791. The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlationsPearson's r from 0.58 (95% CI: 0.52-0.65 to 0.74 (95% CI: 0.69-0.78. The patient care indicators, except item 2, showed acceptable correlationsPearson's r from 0.40 (95% CI: 0.31-0.48 to 0.82 (95% CI: 0.78-0.85. The instrument also showed high discriminant validity (prescribing indicators P<0.0001 and patient care indicators P<0.0001. Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development.

  6. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Science.gov (United States)

    Koley, Munmun; Saha, Subhranil; Ghosh, Shubhamoy; Nag, Goutam; Kundu, Monojit; Mondal, Ramkumar; Purkait, Rajib; Patra, Supratim

    2014-01-01

    A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H), Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items) and patient care indicators (5 items). Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791). The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlationsPearson's r from 0.58 (95% CI: 0.52-0.65) to 0.74 (95% CI: 0.69-0.78). The patient care indicators, except item 2, showed acceptable correlationsPearson's r from 0.40 (95% CI: 0.31-0.48) to 0.82 (95% CI: 0.78-0.85). The instrument also showed high discriminant validity (prescribing indicators P < 0.0001 and patient care indicators P < 0.0001). Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development. PMID:25379474

  7. Validity and reproducibility of a food frequency questionnaire focused on the Mediterranean diet for the Quebec population.

    Science.gov (United States)

    Cantin, J; Latour, E; Ferland-Verry, R; Morales Salgado, S; Lambert, J; Faraj, M; Nigam, A

    2016-02-01

    Validated dietary assessment methods specific to population and food habits are needed to conduct randomized clinical trials evaluating the efficacy of the Mediterranean diet in primary and secondary prevention of cardiovascular disease. Therefore, the aim of our study was to assess the reproducibility and the relative validity of a French language semi-quantitative food frequency questionnaire (FFQ) focused on the Mediterranean diet within the population of Quebec. Fifty-three participants aged 19-86 years with and without coronary heart disease were recruited, and randomized in 3 groups in a crossover design where the sequence of administration of two FFQs and a dietary record (DR) differed in each group. The FFQ includes 157 food items and was designed to measure food intake over one month. It was administered twice 3-5 weeks apart to assess reproducibility and was compared to a 12-day DR to assess validity. For reproducibility (n = 47), intraclass correlation coefficients (ICCs) for energy and 33 nutrients ranged from 0.38 to 0.91 (mean 0.63). For validity, the Pearson's correlation coefficients between the DR and the FFQ pre-DR ranged from 0.26 to 0.84 (mean 0.55) and ICCs ranged from 0.25 to 0.84 (mean 0.54). As for the DR and the FFQ post-DR, the Pearson's correlation coefficients ranged from 0.36 to 0.83 (mean 0.55) and the ICCs ranged from 0.36 to 0.83 (mean 0.53). This FFQ demonstrates good reproducibility and validity for most key nutrients of the Mediterranean diet for the Quebec population. Copyright © 2015 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  8. Validation of Web-Based Physical Activity Measurement Systems Using Doubly Labeled Water

    Science.gov (United States)

    Yamaguchi, Yukio; Yamada, Yosuke; Tokushima, Satoru; Hatamoto, Yoichi; Sagayama, Hiroyuki; Kimura, Misaka; Higaki, Yasuki; Tanaka, Hiroaki

    2012-01-01

    Background Online or Web-based measurement systems have been proposed as convenient methods for collecting physical activity data. We developed two Web-based physical activity systems—the 24-hour Physical Activity Record Web (24hPAR WEB) and 7 days Recall Web (7daysRecall WEB). Objective To examine the validity of two Web-based physical activity measurement systems using the doubly labeled water (DLW) method. Methods We assessed the validity of the 24hPAR WEB and 7daysRecall WEB in 20 individuals, aged 25 to 61 years. The order of email distribution and subsequent completion of the two Web-based measurements systems was randomized. Each measurement tool was used for a week. The participants’ activity energy expenditure (AEE) and total energy expenditure (TEE) were assessed over each week using the DLW method and compared with the respective energy expenditures estimated using the Web-based systems. Results The mean AEE was 3.90 (SD 1.43) MJ estimated using the 24hPAR WEB and 3.67 (SD 1.48) MJ measured by the DLW method. The Pearson correlation for AEE between the two methods was r = .679 (P WEB and 3.80 (SD 1.36) MJ by the DLW method. The Pearson correlation for AEE between the two methods was r = .144 (P = .54). The Bland-Altman 95% limits of agreement ranged from –3.83 to 4.81 MJ between the two methods. The Pearson correlation for TEE between the two methods was r = .590 (P = .006). The average input times using terminal devices were 8 minutes and 10 seconds for the 24hPAR WEB and 6 minutes and 38 seconds for the 7daysRecall WEB. Conclusions Both Web-based systems were found to be effective methods for collecting physical activity data and are appropriate for use in epidemiological studies. Because the measurement accuracy of the 24hPAR WEB was moderate to high, it could be suitable for evaluating the effect of interventions on individuals as well as for examining physical activity behavior. PMID:23010345

  9. Concurrent validity and reliability of the Alberta Infant Motor Scale in premature infants.

    Science.gov (United States)

    Almeida, Kênnea Martins; Dutra, Maria Virginia Peixoto; Mello, Rosane Reis de; Reis, Ana Beatriz Rodrigues; Martins, Priscila Silveira

    2008-01-01

    To verify the concurrent validity and interobserver reliability of the Alberta Infant Motor Scale (AIMS) in premature infants followed-up at the outpatient clinic of Instituto Fernandes Figueira, Fundação Oswaldo Cruz (IFF/Fiocruz), in Rio de Janeiro, Brazil. A total of 88 premature infants were enrolled at the follow-up clinic at IFF/Fiocruz, between February and December of 2006. For the concurrent validity study, 46 infants were assessed at either 6 (n = 26) or 12 (n = 20) months' corrected age using the AIMS and the second edition of the Bayley Scales of Infant Development, by two different observers, and applying Pearson's correlation coefficient to analyze the results. For the reliability study, 42 infants between 0 and 18 months were assessed using the Alberta Infant Motor Scale, by two different observers and the results analyzed using the intraclass correlation coefficient. The concurrent validity study found a high level of correlation between the two scales (r = 0.95) and one that was statistically significant (p system.

  10. Validation analysis of informant's ratings of cognitive function in African Americans and Nigerians

    Science.gov (United States)

    Shen, Jianzhao; Gao, Sujuan; Unverzagt, Frederick W.; Ogunniyi, Adesola; Baiyewu, Olusegun; Gureje, Oye; Hendrie, Hugh C.; Hall, Kathleen S.

    2011-01-01

    SUMMARY Objectives To examine informant validity using the Community Screening Interview for Dementia (CSI ‘D’) both cross-sectionally and longitudinally in two very different cultures and to explore the effects of informants and study participants’ characteristics on the validity of informants’ reports. Methods Elderly African Americans age 65 years and older residing in Indianapolis, USA and elderly Yoruba Nigerians age 65 years and older residing in Ibadan, Nigeria were assessed on cognitive functioning using the CSI ‘D’ at baseline (1992–1993) and five-year follow-up (1997–1998). At baseline, the informant validity in both samples was evaluated against participants’ cognitive tests using Pearson correlation and regular regression models. At follow-up, informants ratings on cognitive decline were assessed against participants’ cognitive decline scores from baseline to follow-up using biserial correlation and logistic regressions. Results At baseline, informants’ reports on cognitive functioning significantly correlated with cognitive scores in both samples (Indianapolis:r = –0.43, p Yoruba Nigerians. At follow-up, informants’ ratings on cognitive decline significantly correlated with the cognitive decline scores (Indianapolis r = 0.38, p cultures, languages and environments. PMID:16802282

  11. Concordance-based Kendall's Correlation for Computationally-Light vs. Computationally-Heavy Centrality Metrics: Lower Bound for Correlation

    Directory of Open Access Journals (Sweden)

    Natarajan Meghanathan

    2017-01-01

    Full Text Available We identify three different levels of correlation (pair-wise relative ordering, network-wide ranking and linear regression that could be assessed between a computationally-light centrality metric and a computationally-heavy centrality metric for real-world networks. The Kendall's concordance-based correlation measure could be used to quantitatively assess how well we could consider the relative ordering of two vertices vi and vj with respect to a computationally-light centrality metric as the relative ordering of the same two vertices with respect to a computationally-heavy centrality metric. We hypothesize that the pair-wise relative ordering (concordance-based assessment of the correlation between centrality metrics is the most strictest of all the three levels of correlation and claim that the Kendall's concordance-based correlation coefficient will be lower than the correlation coefficient observed with the more relaxed levels of correlation measures (linear regression-based Pearson's product-moment correlation coefficient and the network wide ranking-based Spearman's correlation coefficient. We validate our hypothesis by evaluating the three correlation coefficients between two sets of centrality metrics: the computationally-light degree and local clustering coefficient complement-based degree centrality metrics and the computationally-heavy eigenvector centrality, betweenness centrality and closeness centrality metrics for a diverse collection of 50 real-world networks.

  12. Validation of a new strength measurement device for amyotrophic lateral sclerosis clinical trials.

    Science.gov (United States)

    Andres, Patricia L; Skerry, Linda M; Munsat, Theodore L; Thornell, Brenda J; Szymonifka, Jackie; Schoenfeld, David A; Cudkowicz, Merit E

    2012-01-01

    Strength measures with reduced variability and higher sensitivity could improve efficiency in clinical trials of amyotrophic lateral sclerosis (ALS). The Accurate Test of Limb Isometric Strength (ATLIS) was developed to precisely and conveniently measure force in 12 muscle groups. In this study we evaluate the reliability and validity of the ATLIS testing protocol. Twenty healthy adults and 10 patients with ALS were tested twice by the same or by different evaluators to determine test-retest and interrater reliability. Twenty healthy adults were examined using ATLIS and a well-validated strength testing protocol (TQNE) to assess criterion-based validity. Mean absolute variation between tests was 8.6%, and intraclass correlation coefficients for each muscle group were high (range 0.82-0.99). The Pearson correlation coefficient of mean ATLIS and TQNE scores was 0.90. A subject survey demonstrated high user acceptance of ATLIS. ATLIS is convenient for patients and evaluators, produces precise strength measurements, and is easily moved between examining rooms. Copyright © 2011 Wiley Periodicals, Inc.

  13. The City of Hope-Quality of Life-Ostomy Questionnaire: Persian Translation and Validation

    Science.gov (United States)

    Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M

    2014-01-01

    Background: Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. Aim: This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). Subjects and Methods: This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Results: Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. Conclusion: The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future. PMID:25221719

  14. The city of hope-quality of life-ostomy questionnaire: persian translation and validation.

    Science.gov (United States)

    Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M

    2014-07-01

    Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future.

  15. Clinical manifestations and management of four children with Pearson syndrome.

    Science.gov (United States)

    Tumino, Manuela; Meli, Concetta; Farruggia, Piero; La Spina, Milena; Faraci, Maura; Castana, Cinzia; Di Raimondo, Vincenzo; Alfano, Marivana; Pittalà, Annarita; Lo Nigro, Luca; Russo, Giovanna; Di Cataldo, Andrea

    2011-12-01

    Pearson marrow-pancreas syndrome is a fatal disorder mostly diagnosed during infancy and caused by mutations of mitochondrial DNA. We hereby report on four children affected by Pearson syndrome with hematological disorders at onset. The disease was fatal to three of them and the fourth one, who received hematopoietic stem cell transplantation, died of secondary malignancy. In this latter patient transplantation corrected hematological and non-hematological issues like metabolic acidosis, and we therefore argue that it could be considered as a useful option in an early stage of the disease. Copyright © 2011 Wiley Periodicals, Inc.

  16. Cross-cultural adaptation, validation and reliability of the brazilian version of the Richmond Compulsive Buying Scale

    Directory of Open Access Journals (Sweden)

    Priscilla Leite

    2013-03-01

    Full Text Available OBJECTIVE: To present the process of transcultural adaptation of the Richmond Compulsive Buying Scale to Brazilian Portuguese. METHODS: For the semantic adaptation step, the scale was translated to Portuguese and then back-translated to English by two professional translators and one psychologist, without any communication between them. The scale was then applied to 20 participants from the general population for language adjustments. For the construct validation step, an exploratory factor analysis was performed, using the scree plot test, principal component analysis for factor extraction, and Varimax rotation. For convergent validity, the correlation matrix was analyzed through Pearson's coefficient. RESULTS: The scale showed easy applicability, satisfactory internal consistency (Cronbach's alpha=.87, and a high correlation with other rating scales for compulsive buying disorder, indicating that it is suitable to be used in the assessment and diagnosis of compulsive buying disorder, as it presents psychometric validity. CONCLUSION: The Brazilian Portuguese version of the Richmond Compulsive Buying Scale has good validity and reliability

  17. Cross-cultural adaptation, validation and reliability of the brazilian version of the Richmond Compulsive Buying Scale.

    Science.gov (United States)

    Leite, Priscilla; Rangé, Bernard; Kukar-Kiney, Monika; Ridgway, Nancy; Monroe, Kent; Ribas Junior, Rodolfo; Landeira Fernandez, J; Nardi, Antonio Egidio; Silva, Adriana

    2013-03-01

    To present the process of transcultural adaptation of the Richmond Compulsive Buying Scale to Brazilian Portuguese. For the semantic adaptation step, the scale was translated to Portuguese and then back-translated to English by two professional translators and one psychologist, without any communication between them. The scale was then applied to 20 participants from the general population for language adjustments. For the construct validation step, an exploratory factor analysis was performed, using the scree plot test, principal component analysis for factor extraction, and Varimax rotation. For convergent validity, the correlation matrix was analyzed through Pearson's coefficient. The scale showed easy applicability, satisfactory internal consistency (Cronbach's alpha=.87), and a high correlation with other rating scales for compulsive buying disorder, indicating that it is suitable to be used in the assessment and diagnosis of compulsive buying disorder, as it presents psychometric validity. The Brazilian Portuguese version of the Richmond Compulsive Buying Scale has good validity and reliability.

  18. Clinical and Pathological Staging Validation in the Eighth Edition of the TNM Classification for Lung Cancer: Correlation between Solid Size on Thin-Section Computed Tomography and Invasive Size in Pathological Findings in the New T Classification.

    Science.gov (United States)

    Aokage, Keiju; Miyoshi, Tomohiro; Ishii, Genichiro; Kusumoto, Masahiro; Nomura, Shogo; Katsumata, Shinya; Sekihara, Keigo; Hishida, Tomoyuki; Tsuboi, Masahiro

    2017-09-01

    The aim of this study was to validate the new eighth edition of the TNM classification and to elucidate whether radiological solid size corresponds to pathological invasive size incorporated in this T factor. We analyzed the data on 1792 patients who underwent complete resection from 2003 to 2011 at the National Cancer Center Hospital East, Japan. We reevaluated preoperative thin-section computed tomography (TSCT) to determine solid size and pathological invasive size using the fourth edition of the WHO classification and reclassified them according to the new TNM classification. The discriminative power of survival curves by the seventh edition was compared with that by the eighth edition by using concordance probability estimates and Akaike's information criteria calculated using a univariable Cox regression model. Pearson's correlation coefficient was calculated to elucidate the correlation between radiological solid size using TSCT and pathological invasive size. The overall survival curves in the eighth edition were well distinct at each clinical and pathological stage. The 5-year survival rates of patients with clinical and pathological stage 0 newly defined were both 100%. The concordance probability estimate and Akaike's information criterion values of the eighth edition were higher than those of the seventh edition in discriminatory power for overall survival. Solid size on TSCT scan and pathological invasive size showed a positive linear relationship, and Pearson's correlation coefficient was calculated as 0.83, which indicated strong correlation. This TNM classification will be feasible regarding patient survival, and radiological solid size correlates significantly with pathological invasive size as a new T factor. Copyright © 2017 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of the validity of the Foot Function Index in measuring outcomes in patients with foot and ankle disorders.

    Science.gov (United States)

    SooHoo, Nelson F; Samimi, David B; Vyas, Raj M; Botzler, Tin

    2006-01-01

    There is uncertainty regarding which outcomes tools should be used to report the results of treatment for patients with foot and ankle disorders. This study evaluates the validity of the Foot Function Index (FFI) by examining its level of correlation to the Medical Outcomes Study Short Form-36 (SF-36). The SF-36 is an extensively validated outcomes tool that has been used as a benchmark in examining the validity of several orthopaedic outcomes tools. Seventy-three patients were recruited at a tertiary referral foot and ankle practice. Patients completed packets which included informed consent forms, the FFI, and the SF-36 questionnaires. The questionnaires were scored and Pearson correlation coefficients were determined between the three domains of the FFI and the eight SF-36 sub-scales, as well as the two SF-36 summary scales. Sixty-nine patients completed an adequate number of items to be included in the study. The mean age of the patient sample was 46 (range 16 to 82) years and 44 were women (64%). Twenty-one patients (30%) had conditions affecting the forefoot, while 48 patients (70%) had conditions affecting the ankle or hindfoot. All three FFI domains had moderate to high levels of correlation to many of the SF-36 scales. The Disability domain of the FFI had the most consistent level of correlation to the SF-36 with Pearson coefficients in the range of -0.23 to -0.69. The Activity Limitation (r=-0.28 to -0.64) and Pain domains (r=-0.10 to -0.61) also demonstrated moderate levels of correlation to several of the SF-36 scales. The consistently moderate to high levels of correlation of the FFI to the SF-36 seen in this study support the FFI as a valid measure of health status. This suggests that the FFI is a reasonable method to monitor patient outcomes. Future studies should focus on determining if the FFI improves responsiveness to clinical change when used in combination with generic instruments like the SF-36.

  20. Robust correlation analyses: false positive and power validation using a new open source matlab toolbox.

    Science.gov (United States)

    Pernet, Cyril R; Wilcox, Rand; Rousselet, Guillaume A

    2012-01-01

    Pearson's correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab((R)) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand.

  1. Presentation of valid correlations in some morphological

    Directory of Open Access Journals (Sweden)

    Florian Miftari

    2018-05-01

    Full Text Available Study-research deals with younger students of both sexes aged 13-14, who, besides attending classes of physical education and sports, also practice in basketball schools in the city of Pristina. The experiment contains a total of 7 morphological variables, while four tests of basic motion skills and seven variables are from specific motion skills. In this study, the verification and analysis of the correlation of morphological characteristics and basic and situational motor skills in both groups of both sexes (boys and girls were treated. Based on the results obtained between several variables, valid correlations with high coefficients are presented, whereas among the variables are presented correlations with optimal values. The experimentation in question includes the number of 80 entities of both sexes; the group of 40 boys and the other group consisting of 40 girls who have undergone the tests for this study-experiment.

  2. Estimation of the simple correlation coefficient.

    Science.gov (United States)

    Shieh, Gwowen

    2010-11-01

    This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.

  3. INTERPRETING THE DISTANCE CORRELATION RESULTS FOR THE COMBO-17 SURVEY

    International Nuclear Information System (INIS)

    Richards, Mercedes T.; Richards, Donald St. P.; Martínez-Gómez, Elizabeth

    2014-01-01

    The accurate classification of galaxies in large-sample astrophysical databases of galaxy clusters depends sensitively on the ability to distinguish between morphological types, especially at higher redshifts. This capability can be enhanced through a new statistical measure of association and correlation, called the distance correlation coefficient, which has more statistical power to detect associations than does the classical Pearson measure of linear relationships between two variables. The distance correlation measure offers a more precise alternative to the classical measure since it is capable of detecting nonlinear relationships that may appear in astrophysical applications. We showed recently that the comparison between the distance and Pearson correlation coefficients can be used effectively to isolate potential outliers in various galaxy data sets, and this comparison has the ability to confirm the level of accuracy associated with the data. In this work, we elucidate the advantages of distance correlation when applied to large databases. We illustrate how the distance correlation measure can be used effectively as a tool to confirm nonlinear relationships between various variables in the COMBO-17 database, including the lengths of the major and minor axes, and the alternative redshift distribution. For these outlier pairs, the distance correlation coefficient is routinely higher than the Pearson coefficient since it is easier to detect nonlinear relationships with distance correlation. The V-shaped scatter plots of Pearson versus distance correlation coefficients also reveal the patterns with increasing redshift and the contributions of different galaxy types within each redshift range

  4. Statistical analysis of latent generalized correlation matrix estimation in transelliptical distribution

    OpenAIRE

    Han, Fang; Liu, Han

    2016-01-01

    Correlation matrices play a key role in many multivariate methods (e.g., graphical model estimation and factor analysis). The current state-of-the-art in estimating large correlation matrices focuses on the use of Pearson's sample correlation matrix. Although Pearson's sample correlation matrix enjoys various good properties under Gaussian models, it is not an effective estimator when facing heavy-tailed distributions. As a robust alternative, Han and Liu [J. Am. Stat. Assoc. 109 (2015) 275-2...

  5. [Psychometric validation in Spanish of the Brazilian short version of the Primary Care Assessment Tools-users questionnaire for the evaluation of the orientation of health systems towards primary care].

    Science.gov (United States)

    Vázquez Peña, Fernando; Harzheim, Erno; Terrasa, Sergio; Berra, Silvina

    2017-02-01

    To validate the Brazilian short version of the PCAT for adult patients in Spanish. Analysis of secondary data from studies made to validate the extended version of the PCAT questionnaire. City of Córdoba, Argentina. Primary health care. The sample consisted of 46% of parents, whose children were enrolled in secondary education in three institutes in the city of Cordoba, and the remaining 54% were adult users of the National University of Cordoba Health Insurance. Pearson's correlation coefficient comparing the extended and short versions. Goodness-of-fit indices in confirmatory factor analysis, composite reliability, average variance extracted, and Cronbach's alpha values, in order to assess the construct validity and the reliability of the short version. The values of Pearson's correlation coefficient between this short version and the long version were high .818 (Pmedia extracted: .3306, since 3 variables had weak factorials loads. The Cronbach's alpha was acceptable (.85). The short version of the PCAT-users developed in Brazil showed an acceptable psychometric performance in Spanish as a quick assessment tool, in a comparative study with the extended version. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  6. Validity of food frequency questionnaire-based estimates of long-term long-chain n-3 polyunsaturated fatty acid intake.

    Science.gov (United States)

    Wallin, Alice; Di Giuseppe, Daniela; Burgaz, Ann; Håkansson, Niclas; Cederholm, Tommy; Michaëlsson, Karl; Wolk, Alicja

    2014-01-01

    To evaluate how long-term dietary intake of long-chain n-3 polyunsaturated fatty acids (LCn-3 PUFAs), estimated by repeated food frequency questionnaires (FFQs) over 15 years, is correlated with LCn-3 PUFAs in adipose tissue (AT). Subcutaneous adipose tissue was obtained in 2003-2004 (AT-03) from 239 randomly selected women, aged 55-75 years, after completion of a 96-item FFQ (FFQ-03). All participants had previously returned an identical FFQ in 1997 (FFQ-97) and a 67-item version in 1987-1990 (FFQ-87). Pearson product-moment correlations were used to evaluate associations between intake of total and individual LCn-3 PUFAs as estimated by the three FFQ assessments and AT-03 content (% of total fatty acids). FFQ-estimated mean relative intake of LCn-3 PUFAs (% of total fat intake) increased between all three assessments (FFQ-87, 0.55 ± 0.34; FFQ-97, 0.74 ± 0.64; FFQ-03, 0.88 ± 0.56). Validity, in terms of Pearson correlations between FFQ-03 estimates and AT-03 content, was 0.41 (95% CI 0.30-0.51) for total LCn-3 PUFA and ranged from 0.29 to 0.48 for individual fatty acids; lower correlation was observed among participants with higher percentage body fat. With regard to long-term intake estimates, past dietary intake was also correlated with AT-03 content, with correlation coefficients in the range of 0.21-0.33 and 0.21-0.34 for FFQ-97 and FFQ-87, respectively. The correlations were improved by using average estimates from two or more FFQ assessments. Exclusion of fish oil supplement users (14%) did not alter the correlations. These data indicate reasonable validity of FFQ-based estimates of long-term (up to 15 years) LCn-3 PUFA intake, justifying their use in studies of diet-disease associations.

  7. Creation and Validation of the Self-esteem/Self-image Female Sexuality (SESIFS Questionnaire

    Directory of Open Access Journals (Sweden)

    Maria C.O. Lordello

    2014-01-01

    Full Text Available Introduction Self-esteem and self-image are psychological aspects that affect sexual function. AIMS To validate a new measurement tool that correlates the concepts of self-esteem, self-image, and sexuality. Methods A 20-question test (the self-esteem/self-image female sexuality [SESIFS] questionnaire was created and tested on 208 women. Participants answered: Rosenberg's self-esteem scale, the female sexual quotient (FSQ, and the SESIFS questionnaire. Pearson's correlation coefficient was used to test concurrent validity of the SESIFS against Rosenberg's self-esteem scale and the FSQ. Reliability was tested using the Cronbach's alpha coefficient. Result The new questionnaire had a good overall reliability (Cronbach's alpha r = 0.862, p < 0.001, but the sexual domain scored lower than expected ( r = 0.65. The validity was good: overall score r = 0.38, p < 0.001, self-esteem domain r = 0.32, p < 0.001, self-image domain r = 0.31, p < 0.001, sexual domain r = 0.29, p < 0.001. Conclusions The SESIFS questionnaire has limitations in measuring the correlation among self-esteem, self-image, and sexuality domains. A new, revised version is being tested and will be presented in an upcoming publication.

  8. Reducing Bias and Error in the Correlation Coefficient Due to Nonnormality

    Science.gov (United States)

    Bishara, Anthony J.; Hittner, James B.

    2015-01-01

    It is more common for educational and psychological data to be nonnormal than to be approximately normal. This tendency may lead to bias and error in point estimates of the Pearson correlation coefficient. In a series of Monte Carlo simulations, the Pearson correlation was examined under conditions of normal and nonnormal data, and it was compared…

  9. Clustering stocks using partial correlation coefficients

    Science.gov (United States)

    Jung, Sean S.; Chang, Woojin

    2016-11-01

    A partial correlation analysis is performed on the Korean stock market (KOSPI). The difference between Pearson correlation and the partial correlation is analyzed and it is found that when conditioned on the market return, Pearson correlation coefficients are generally greater than those of the partial correlation, which implies that the market return tends to drive up the correlation between stock returns. A clustering analysis is then performed to study the market structure given by the partial correlation analysis and the members of the clusters are compared with the Global Industry Classification Standard (GICS). The initial hypothesis is that the firms in the same GICS sector are clustered together since they are in a similar business and environment. However, the result is inconsistent with the hypothesis and most clusters are a mix of multiple sectors suggesting that the traditional approach of using sectors to determine the proximity between stocks may not be sufficient enough to diversify a portfolio.

  10. Oxford Shoulder Score: A Cross-Cultural Adaptation and Validation Study of the Persian Version in Iran.

    Science.gov (United States)

    Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Razi, Shiva; Mardani-Kivi, Mohsen; Reza Kachooei, Amir

    2015-09-01

    Oxford shoulder score is a specific 12-item patient-reported tool for evaluation of patients with inflammatory and degenerative disorders of the shoulder. Since its introduction, it has been translated and culturally adapted in some Western and Eastern countries. The aim of this study was to translate the Oxford Shoulder Score (OSS) in Persian and to test its validity and reliability in Persian speaking population in Iran. One hundred patients with degenerative or inflammatory shoulder problem participated in the survey in 2012. All patients completed the Persian version of OSS, Persian DASH and the SF-36 for testing validity. Randomly, 37 patients filled out the Persian OSS again three days after the initial visit to assess the reliability of the questionnaire. Cronbach's alpha coefficient was 0.93. The intraclass correlation coefficient was 0.93. In terms of validity, there was a significant correlation between the Persian OSS and DASH and SF-36 scores (P Persian version of the OSS proved to be a valid, reliable, and reproducible tool as demonstrated by high Cronbach's alpha and Pearson's correlation coefficients. The Persian transcript of OSS is administrable to Persian speaking patients with shoulder condition and it is understandable by them.

  11. Validity and reliability of an adapted Thai version of Scoliosis Research Society-22 questionnaire for adolescent idiopathic scoliosis.

    Science.gov (United States)

    Sathira-Angkura, Vera; Pithankuakul, Kongkit; Sakulpipatana, Susana; Piyaskulkaew, Chaiwat; Kunakornsawat, Sombat

    2012-04-20

    Cross-sectional observational study to investigate psychometric properties of an adapted Thai version of the refined Scoliosis Research Society-22 (SRS-22) questionnaire. To evaluate the reliability and validity of the adapted Thai version of the refined SRS-22 questionnaire. The SRS-22 questionnaire is a valid instrument for assessing the health-related quality of life for patients with adolescent idiopathic scoliosis. Recently, the questionnaire has been translated and validated in many languages for non-English-speaking countries. Translation/retranslation of the English version of the SRS-22 was conducted, and the cross-cultural adaptation process was performed. The Thai version SRS-22 and previously validated Thai version Short-Form survey version 2.0 (SF-36V2) questionnaires were administered to 77 patients with adolescent idiopathic scoliosis who had surgical treatment. Fifty-eight patients (52 adolescent girls) had filled out the first set of questionnaires. Thirty patients of the first-time responders completed the second set of questionnaires. The mean age at the time of operation was 14.6 years and the mean age at the time of the final follow-up was 18.7 years. The mean preoperative scoliosis curve magnitude was 55.4° (range, 30°-95°) and postoperative curve magnitude was 20.1° (range, 0°-60°). Internal consistency was determined with Cronbach α coefficient. Intraclass correlation coefficient was used for test-retest reliability. Concurrent validity was evaluated by comparing SRS-22 domains with relevant domains in the SF-36V2 questionnaire, using the Pearson correlation coefficient. The mean overall Cronbach α coefficient of the adapted Thai version SRS-22 was 0.76. The 2 of corresponding domains (mental health = 0.80 and self-image = 0.83) had satisfactory internal consistency and the remaining domains (pain = 0.78; function/activity = 0.74; and satisfaction = 0.76) were good. The intraclass correlation coefficient for 5 domains was ranged from

  12. Body image in patients with adolescent idiopathic scoliosis: validation of the Body Image Disturbance Questionnaire--Scoliosis Version.

    Science.gov (United States)

    Auerbach, Joshua D; Lonner, Baron S; Crerand, Canice E; Shah, Suken A; Flynn, John M; Bastrom, Tracey; Penn, Phedra; Ahn, Jennifer; Toombs, Courtney; Bharucha, Neil; Bowe, Whitney P; Newton, Peter O

    2014-04-16

    Appearance concerns in individuals with adolescent idiopathic scoliosis can result in impairment in daily functioning, or body image disturbance. The Body Image Disturbance Questionnaire (BIDQ) is a self-reported, seven-question instrument that measures body image disturbance in general populations; no studies have specifically examined body image disturbance in those with adolescent idiopathic scoliosis. This study aimed to validate a modified version of the BIDQ in a population with adolescent idiopathic scoliosis and to establish discriminant validity by comparing responses of operatively and nonoperatively treated patients with those of normal controls. In the first phase, a multicenter study of forty-nine patients (mean age, fourteen years; thirty-seven female) with adolescent idiopathic scoliosis was performed to validate the BIDQ-Scoliosis version (BIDQ-S). Participants completed the BIDQ-S, Scoliosis Research Society (SRS)-22, Children's Depression Index (CDI), and Body Esteem Scale for Adolescents and Adults (BESAA) questionnaires. Descriptive statistics and Pearson correlation coefficients were calculated. In the second phase, ninety-eight patients with adolescent idiopathic scoliosis (mean age, 15.7 years; seventy-five female) matched by age and sex with ninety-eight healthy adolescents were enrolled into a single-center study to evaluate the discriminant validity of the BIDQ-S. Subjects completed the BIDQ-S and a demographic form before treatment. Independent-sample t tests and Pearson correlation coefficients were calculated. The BIDQ-S was internally consistent (Cronbach alpha = 0.82), and corrected item total correlations ranged from 0.47 to 0.67. The BIDQ-S was significantly correlated with each domain of the SRS-22 and the total score (r = -0.50 to -0.72, p ≤ 0.001), with the CDI (r = 0.31, p = 0.03), and with the BESAA (r = 0.60, p image disturbance compared with healthy controls. To our knowledge, this user-friendly instrument is the first to

  13. Distance correlation methods for discovering associations in large astrophysical databases

    International Nuclear Information System (INIS)

    Martínez-Gómez, Elizabeth; Richards, Mercedes T.; Richards, Donald St. P.

    2014-01-01

    High-dimensional, large-sample astrophysical databases of galaxy clusters, such as the Chandra Deep Field South COMBO-17 database, provide measurements on many variables for thousands of galaxies and a range of redshifts. Current understanding of galaxy formation and evolution rests sensitively on relationships between different astrophysical variables; hence an ability to detect and verify associations or correlations between variables is important in astrophysical research. In this paper, we apply a recently defined statistical measure called the distance correlation coefficient, which can be used to identify new associations and correlations between astrophysical variables. The distance correlation coefficient applies to variables of any dimension, can be used to determine smaller sets of variables that provide equivalent astrophysical information, is zero only when variables are independent, and is capable of detecting nonlinear associations that are undetectable by the classical Pearson correlation coefficient. Hence, the distance correlation coefficient provides more information than the Pearson coefficient. We analyze numerous pairs of variables in the COMBO-17 database with the distance correlation method and with the maximal information coefficient. We show that the Pearson coefficient can be estimated with higher accuracy from the corresponding distance correlation coefficient than from the maximal information coefficient. For given values of the Pearson coefficient, the distance correlation method has a greater ability than the maximal information coefficient to resolve astrophysical data into highly concentrated horseshoe- or V-shapes, which enhances classification and pattern identification. These results are observed over a range of redshifts beyond the local universe and for galaxies from elliptical to spiral.

  14. Optimization of the two-sample rank Neyman-Pearson detector

    Science.gov (United States)

    Akimov, P. S.; Barashkov, V. M.

    1984-10-01

    The development of optimal algorithms concerned with rank considerations in the case of finite sample sizes involves considerable mathematical difficulties. The present investigation provides results related to the design and the analysis of an optimal rank detector based on a utilization of the Neyman-Pearson criteria. The detection of a signal in the presence of background noise is considered, taking into account n observations (readings) x1, x2, ... xn in the experimental communications channel. The computation of the value of the rank of an observation is calculated on the basis of relations between x and the variable y, representing interference. Attention is given to conditions in the absence of a signal, the probability of the detection of an arriving signal, details regarding the utilization of the Neyman-Pearson criteria, the scheme of an optimal rank, multichannel, incoherent detector, and an analysis of the detector.

  15. High correlation between performance on a virtual-reality simulator and real-life cataract surgery

    DEFF Research Database (Denmark)

    Thomsen, Ann Sofia Skou; Smith, Phillip; Subhi, Yousif

    2017-01-01

    -tracking software of cataract surgical videos with a Pearson correlation coefficient of -0.70 (p = 0.017). CONCLUSION: Performance on the EyeSi simulator is significantly and highly correlated to real-life surgical performance. However, it is recommended that performance assessments are made using multiple data......PURPOSE: To investigate the correlation in performance of cataract surgery between a virtual-reality simulator and real-life surgery using two objective assessment tools with evidence of validity. METHODS: Cataract surgeons with varying levels of experience were included in the study. All...... antitremor training, forceps training, bimanual training, capsulorhexis and phaco divide and conquer. RESULTS: Eleven surgeons were enrolled. After a designated warm-up period, the proficiency-based test on the EyeSi simulator was strongly correlated to real-life performance measured by motion...

  16. [Cognition-correlation indices of gender schema: tests of validity].

    Science.gov (United States)

    Ishida, E

    1994-02-01

    Four-hundred and seventy-seven subjects evaluated a set of traits and behaviors in terms of how masculine and feminine they were and in terms of how well they represented their real and ideal self-images. Within-individual correlation coefficients between these evaluations were proposed as measures of psychological gender schemata, because they would represent the degree of matching between the subjects' gender-image and ideal/real self-images of gender-related attributes. The present study aims at examining the construct validity of these measures, by testing them to psychological variables that are known to reflect gender identity. The individual difference variables used as criteria were (a) satisfaction with one's own sex, (b) general happiness, (c) self-esteem (d) gender-conflict, and (e) school and occupational achievement need. Correlations between the gender-schema indices and the criteria variables supported the construct validity of those measures. Advantages of the present measurement over the conventional simple trait approach, such as BSRI, or PAQ are discussed.

  17. Commercialising Comparison: Pearson Puts the TLC in Soft Capitalism

    Science.gov (United States)

    Hogan, Anna; Sellar, Sam; Lingard, Bob

    2016-01-01

    This paper provides a critical policy analysis of "The Learning Curve" (TLC) (2012), an initiative developed by the multinational edu-business, Pearson, in conjunction with the Economist Intelligence Unit. "TLC" exemplifies the commercialising of comparison and the efforts of edu-businesses to strategically position themselves…

  18. Assessing Temporal Stability for Coarse Scale Satellite Moisture Validation in the Maqu Area, Tibet

    Science.gov (United States)

    Bhatti, Haris Akram; Rientjes, Tom; Verhoef, Wouter; Yaseen, Muhammad

    2013-01-01

    This study evaluates if the temporal stability concept is applicable to a time series of satellite soil moisture images so to extend the common procedure of satellite image validation. The area of study is the Maqu area, which is located in the northeastern part of the Tibetan plateau. The network serves validation purposes of coarse scale (25–50 km) satellite soil moisture products and comprises 20 stations with probes installed at depths of 5, 10, 20, 40, 80 cm. The study period is 2009. The temporal stability concept is applied to all five depths of the soil moisture measuring network and to a time series of satellite-based moisture products from the Advance Microwave Scanning Radiometer (AMSR-E). The in-situ network is also assessed by Pearsons's correlation analysis. Assessments by the temporal stability concept proved to be useful and results suggest that probe measurements at 10 cm depth best match to the satellite observations. The Mean Relative Difference plot for satellite pixels shows that a RMSM pixel can be identified but in our case this pixel does not overlay any in-situ station. Also, the RMSM pixel does not overlay any of the Representative Mean Soil Moisture (RMSM) stations of the five probe depths. Pearson's correlation analysis on in-situ measurements suggests that moisture patterns over time are more persistent than over space. Since this study presents first results on the application of the temporal stability concept to a series of satellite images, we recommend further tests to become more conclusive on effectiveness to broaden the procedure of satellite validation. PMID:23959237

  19. External Validation of a Case-Mix Adjustment Model for the Standardized Reporting of 30-Day Stroke Mortality Rates in China.

    Science.gov (United States)

    Yu, Ping; Pan, Yuesong; Wang, Yongjun; Wang, Xianwei; Liu, Liping; Ji, Ruijun; Meng, Xia; Jing, Jing; Tong, Xu; Guo, Li; Wang, Yilong

    2016-01-01

    A case-mix adjustment model has been developed and externally validated, demonstrating promise. However, the model has not been thoroughly tested among populations in China. In our study, we evaluated the performance of the model in Chinese patients with acute stroke. The case-mix adjustment model A includes items on age, presence of atrial fibrillation on admission, National Institutes of Health Stroke Severity Scale (NIHSS) score on admission, and stroke type. Model B is similar to Model A but includes only the consciousness component of the NIHSS score. Both model A and B were evaluated to predict 30-day mortality rates in 13,948 patients with acute stroke from the China National Stroke Registry. The discrimination of the models was quantified by c-statistic. Calibration was assessed using Pearson's correlation coefficient. The c-statistic of model A in our external validation cohort was 0.80 (95% confidence interval, 0.79-0.82), and the c-statistic of model B was 0.82 (95% confidence interval, 0.81-0.84). Excellent calibration was reported in the two models with Pearson's correlation coefficient (0.892 for model A, pcase-mix adjustment model could be used to effectively predict 30-day mortality rates in Chinese patients with acute stroke.

  20. On Neyman-Pearson Theory: Information Content of an Experiment and a Fancy Paradox

    Directory of Open Access Journals (Sweden)

    Benito Vittorio Frosini

    2007-10-01

    Full Text Available Two topics, connected with Neyman-Pearson theory of testing hypotheses, are treated in this article. The first topic is related to the information content of an experiment; after a short outline of ordinal comparability of experiments, the two most popular information measures – by Fisher and by Kullback-Leibler – are considered. As far as we require a comparison of two experiments at a time, the superiority of the couple (a,b of the two error probabilities in the Neyman-Pearson approach is easily established, owing to their clear operational meaning. The second topic deals with the so called Jeffreys – or Lindley – paradox: it can be shown that, if we attach a positive probability to a point null hypothesis, some «paradoxical» posterior probabilities – in a Bayesian approach – result in sharp contrast with the error probabilities in the Neyman-Pearson approach. It is argued that such results are simply the outcomes of absurd assumptions, and it is shown that sensible assumptions about interval – not point – hypotheses can yield posterior probabilities perfectly compatible with the Neyman-Pearson approach (although one must be very careful in making such comparisons, as the two approaches are radically different both in assumptions and in purposes.

  1. Validity and reliability of Verbal Online Subjective Opinion (VOSO and Modified Cooper-Harper scales in measuring of mental workload

    Directory of Open Access Journals (Sweden)

    Reza Charkhandaz Yeganeh

    2016-12-01

    Full Text Available Introduction: High mental workload is one of the important factors that results in errors in safety and occupational health scope and its measurement has high importance. So, this study aimed to determine validity and reliability of Verbal Online Subjective Opinion (VOSO and Modified Cooper-Harper (MCH scales in measuring mental workload. Methods: This study was conducted on 90 male students of Iran University of Medical Sciences. In this study, the Forward-Backward translation was used for translation of scales. Moreover, Content Validity Ratio (CVR and Content Validity Index (CVI were calculated by having suggestion of 6 Ergonomics and Occupational health experts. The Hybrid Memory Search Task software was used to create mental workload. Convergent validity of scales was calculated using correlation of scales with reaction time and then Test-Retest method was used to determine the reliability of scales. Results: Content and convergent validity of scales were confirmed and correlation of both scales with reaction time were higher than 0.8. Moreover for determination of scales reliabilities, Pearson correlation coefficient between scales values in test and retest trials were 0.86 and 0.91 for VOSO and MCH respectively. Conclusion: It seems that in regard to confirmation of validity and reliability of VOSO and MCH in this study and their high correlation with reaction time, it can use these scales in measurement of mental workload.

  2. Relative validity of an FFQ to estimate daily food and nutrient intakes for Chilean adults.

    Science.gov (United States)

    Dehghan, Mahshid; Martinez, Solange; Zhang, Xiaohe; Seron, Pamela; Lanas, Fernando; Islam, Shofiqul; Merchant, Anwar T

    2013-10-01

    FFQ are commonly used to rank individuals by their food and nutrient intakes in large epidemiological studies. The purpose of the present study was to develop and validate an FFQ to rank individuals participating in an ongoing Prospective Urban and Rural Epidemiological (PURE) study in Chile. An FFQ and four 24 h dietary recalls were completed over 1 year. Pearson correlation coefficients, energy-adjusted and de-attenuated correlations and weighted kappa were computed between the dietary recalls and the FFQ. The level of agreement between the two dietary assessment methods was evaluated by Bland-Altman analysis. Temuco, Chile. Overall, 166 women and men enrolled in the present study. One hundred men and women participated in FFQ development and sixty-six individuals participated in FFQ validation. The FFQ consisted of 109 food items. For nutrients, the crude correlation coefficients between the dietary recalls and FFQ varied from 0.14 (protein) to 0.44 (fat). Energy adjustment and de-attenuation improved correlation coefficients and almost all correlation coefficients exceeded 0.40. Similar correlation coefficients were observed for food groups; the highest de-attenuated energy adjusted correlation coefficient was found for margarine and butter (0.75) and the lowest for potatoes (0.12). The FFQ showed moderate to high agreement for most nutrients and food groups, and can be used to rank individuals based on energy, nutrient and food intakes. The validation study was conducted in a unique setting and indicated that the tool is valid for use by adults in Chile.

  3. [A Validation Study of the Modified Korean Version of Ethical Leadership at Work Questionnaire (K-ELW)].

    Science.gov (United States)

    Kim, Jeong-Eon; Park, Eun-Jun

    2015-04-01

    The purpose of this study was to validate the Korean version of the Ethical Leadership at Work questionnaire (K-ELW) that measures RNs' perceived ethical leadership of their nurse managers. The strong validation process suggested by Benson (1998), including translation and cultural adaptation stage, structural stage, and external stage, was used. Participants were 241 RNs who reported their perceived ethical leadership using both the pre-version of K-ELW and a previously known Ethical Leadership Scale, and interactional justice of their managers, as well as their own demographics, organizational commitment and organizational citizenship behavior. Data analyses included descriptive statistics, Pearson correlation coefficients, reliability coefficients, exploratory factor analysis, and confirmatory factor analysis. SPSS 19.0 and Amos 18.0 versions were used. A modified K-ELW was developed from construct validity evidence and included 31 items in 7 domains: People orientation, task responsibility fairness, relationship fairness, power sharing, concern for sustainability, ethical guidance, and integrity. Convergent validity, discriminant validity, and concurrent validity were supported according to the correlation coefficients of the 7 domains with other measures. The results of this study provide preliminary evidence that the modified K-ELW can be adopted in Korean nursing organizations, and reliable and valid ethical leadership scores can be expected.

  4. Concurrent validity of persian version of wechsler intelligence scale for children - fourth edition and cognitive assessment system in patients with learning disorder.

    Science.gov (United States)

    Rostami, Reza; Sadeghi, Vahid; Zarei, Jamileh; Haddadi, Parvaneh; Mohazzab-Torabi, Saman; Salamati, Payman

    2013-04-01

    The aim of this study was to compare the Persian version of the wechsler intelligence scale for children - fourth edition (WISC-IV) and cognitive assessment system (CAS) tests, to determine the correlation between their scales and to evaluate the probable concurrent validity of these tests in patients with learning disorders. One-hundered-sixty-two children with learning disorder who were presented at Atieh Comprehensive Psychiatry Center were selected in a consecutive non-randomized order. All of the patients were assessed based on WISC-IV and CAS scores questionnaires. Pearson correlation coefficient was used to analyze the correlation between the data and to assess the concurrent validity of the two tests. Linear regression was used for statistical modeling. The type one error was considered 5% in maximum. There was a strong correlation between total score of WISC-IV test and total score of CAS test in the patients (r=0.75, Ptest in children with learning disorders. A concurrent validity is established between the two tests and their scales.

  5. Validation of the Sinhala version of the Repeatable Battery for Assessment of Neuropsychological Status (RBANS)

    Science.gov (United States)

    Suraweera, Chathurie; Anandakumar, D; Dahanayake, D; Subendran, M; Perera, U T; Hanwella, Raveen; de Silva, Varuni

    2016-12-30

    Only the Mini mental state examination (MMSE) and Montreal Cognitive Assessment scale have been validated in a Sri Lankan population for the assessment of cognitive functions. Both tests are deficient in the number of domains assessed. Therefore validation of Repeatable Battery for Assessment of Neuropsychological Status is important as it assesses most of the cognitive domains. To culturally adapt RBANS and investigate the validity and reliability of culturally adapted RBANS (RBANS-S). Fifty four participants with major neurocognitive disorder and 60 normal controls aged >50 were administered with RBANS-S at the Cognitive Assessment Unit, Faculty of Medicine, Colombo and National Hospital of Sri Lanka. The participants were selected after a detailed clinical assessment according to Diagnostic and Statistical Manual – 5 criteria. Data were analysed using SPSS data package. The mean age of the sample was 69.5 years. RBANS-S total scale correlated highly with MMSE total score, (Pearson correlational coefficient = 0.793 p=0.01). Criterion validity was assessed using receiver operating curve characteristic analysis and the area under the curve was 0.937. RBANS-S showed strong concurrent validity us indicated by its significant correlations with the MMSE. All of the RBANS-S subtests demonstrated significant correlations with the MMSE subsets. The sensitivity and specificity for RBANS-S was 89% and 85% respectively at a totals score of 80.5. The RBANS-S yielded a reliability coefficient of 0.929. Culturally adapted RBANS-S is a valid and reliable instrument which can be used in assessment of cognitive functions.

  6. The Zarit Caregiver Burden Interview Short Form (ZBI-12) in spouses of Veterans with Chronic Spinal Cord Injury, Validity and Reliability of the Persian Version.

    Science.gov (United States)

    Rajabi-Mashhadi, Mohammad T; Mashhadinejad, Hosein; Ebrahimzadeh, Mohammad H; Golhasani-Keshtan, Farideh; Ebrahimi, Hanieh; Zarei, Zahra

    2015-01-01

    To test the psychometric properties of the Persian version of Zarit Burden Interview (ZBI-12) in the Iranian population. After translating and cultural adaptation of the questionnaire into Persian, 100 caregiver spouses of Iran- Iraq war (1980-88) veterans with chronic spinal cord injury who live in the city of Mashhad, Iran, invited to participate in the study. The Persian version of ZBI-12 accompanied with the Persian SF-36 was completed by the caregivers to test validity of the Persian ZBI-12.A Pearson`s correlation coefficient was calculated for validity testing. In order to assess reliability of the Persian ZBI-12, we administered the ZBI-12 randomly in 48 caregiver spouses again 3 days later. Generally, the internal consistency of the questionnaire was found to be strong (Cronbach's alpha 0.77). Intercorrelation matrix between the different domains of ZBI-12 at test-retest was 0.78. The results revealed that majority of questions the Persian ZBI_12 have a significant correlation to each other. In terms of validity, our results showed that there is significant correlations between some domains of the Persian version the Short Form Health Survey -36 with the Persian Zarit Burden Interview such as Q1 with Role Physical (P=0.03),General Health (P=0.034),Social Functional (0.037), Mental Health (0.023) and Q3 with Physical Function (P=0.001),Viltality (0.002), Socil Function (0.001). Our findings suggest that the Zarit Burden Interview Persian version is both a valid and reliable instrument for measuring the burden of caregivers of individuals with chronic spinal cord injury.

  7. [Design and validation of a questionnaire to assess the level of general knowledge on eating disorders in students of Health Sciences].

    Science.gov (United States)

    Sánchez Socarrás, Violeida; Aguilar Martínez, Alicia; Vaqué Crusellas, Cristina; Milá Villarroel, Raimon; González Rivas, Fabián

    2016-01-01

    To design and validate a questionnaire to assess the level of knowledge regarding eating disorders in college students. Observational, prospective, and longitudinal study, with the design of the questionnaire based on a conceptual review and validation by a cognitive pre-test and pilot test-retest, with analysis of the psychometric properties in each application. University Foundation of Bages, Barcelona. Marco community care. A total of 140 students from Health Sciences; 53 women and 87 men with a mean age of 21.87 years; 28 participated in the pre-test and 112 in the test-retests, 110 students completed the study. Validity and stability study using Cronbach α and Pearson product-moment correlation coefficient statistics; relationship skills with sex and type of study, non-parametric statistical Mann-Whitney and Kruskal-Wallis tests; for demographic variables, absolute or percentage frequencies, as well as mean, central tendency and standard deviation as measures of dispersion were calculated. The statistical significance level was 95% confidence. The questionnaire was obtained that had 10 questions divided into four dimensions (classification, demographics characteristics of patients, risk factors and clinical manifestations of eating disorders). The scale showed good internal consistency in its final version (Cronbach α=0.724) and adequate stability (Pearson correlation 0.749). The designed tool can be accurately used to assess Health Sciences students' knowledge of eating disorders. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  8. Reliability and validity of measures used in assessing dental anxiety in 5- to 15-year-old Croatian children.

    Science.gov (United States)

    Majstorovic, M; Veerkamp, J S; Skrinjaric, I

    2003-12-01

    The aim of the study was to evaluate reliability and validity of different questionnaires and predict related causes, as concomitant factors in assessing different aspects of children's dental anxiety. Children were interviewed on dental anxiety, dispositional risk factors and satisfaction with the dentist after dental treatment had been accomplished. Parents were interviewed on dental anxiety as well. The study population included 165 children (91 boys) aged 5 to 15 years, referred to a university dental clinic by general dental practitioners because of a history of fear and uncooperative behaviour during previous dental visits. Children were treated by two dentists, both experienced in treating fearful children. Statistical analysis was performed in Statistics for Windows, Release 5.5 and Release 7.5. Pearson's correlation coefficients were calculated for validity and Cronbach alpha for reliability of the measures. Spearman Brown prophecy formula was used for correction of the alpha scores. Results The children's total average CFSS-DS score was 27.02, with no significant difference with respect to gender. The highest Cronbach alpha scores regarding reliability were obtained for the S-DAI, the CFSS-DS and the PDAS. Pearson's correlations regarding validity presented significant correlations between the CMFQ, the CDAS and the S-DAI, between the OAS, the CDAS and the S-DAI, as well as between the OAS and the DVSS-SV. Previous negative medical experience had significant influence on children's dental anxiety, supporting Rachman's conditioning theory. Anxious children were more likely to show behaviour problems (aggression) and more introvert in expressing their judgement regarding the dentist. Both the S-DAI and the CFSS-DS, which were standardized in the Croatian population sample, showed the highest reliability in assessment of children's dental anxiety.

  9. The Swedish Exercise Self-Efficacy Scale (ESES-S): reliability and validity in a rheumatoid arthritis population.

    Science.gov (United States)

    Nessen, Thomas; Demmelmaier, Ingrid; Nordgren, Birgitta; Opava, Christina H

    2015-01-01

    The aim of the present study was to investigate aspects of reliability and validity of the Exercise Self-Efficacy Scale (ESES-S) in a rheumatoid arthritis (RA) population. A total of 244 people with RA participating in a physical activity study were included. The six-item ESES-S, exploring confidence in performing exercise, was assessed for test-retest reliability over 4-6 months, and for internal consistency. Construct validity investigated correlation with similar and other constructs. An intraclass correlation coefficient (ICC) of 0.59 (95% CI 0.37-0.73) was found for 84 participants with stable health perceptions between measurement occasions. Cronbach's alpha coefficients of 0.87 and 0.89 were found at the first and second measurements. Corrected item-total correlation single ESES-S items ranged between 0.53 and 0.73. Construct convergent validity for the ESES-S was partly confirmed by correlations with health-enhancing physical activity and outcome expectations respectively (Pearson's r = 0.18, p exercise is crucial for management of symptoms and co-morbidity in rheumatoid arthritis. Self-efficacy for exercise is important to address in rehabilitation as it regulates exercise motivation and behavior. Measurement properties of self-efficacy scales need to be assessed in specific populations and different languages.

  10. The Pearson diffusions: A class of statistically tractable diffusion processes

    DEFF Research Database (Denmark)

    Forman, Julie Lyng; Sørensen, Michael

    The Pearson diffusions is a flexible class of diffusions defined by having linear drift and quadratic squared diffusion coefficient. It is demonstrated that for this class explicit statistical inference is feasible. Explicit optimal martingale estimating func- tions are found, and the corresponding...

  11. Validity and reliability of the Persian version of mobile phone addiction scale

    Directory of Open Access Journals (Sweden)

    Maryam Amidi Mazaheri

    2014-01-01

    Full Text Available Background: With regard to large number of mobile users especially among college students in Iran, addiction to mobile phone is attracting increasing concern. There is an urgent need for reliable and valid instrument to measure this phenomenon. This study examines validity and reliability of the Persian version of mobile phone addiction scale (MPAIS in college students. Materials and Methods: this methodological study was down in Isfahan University of Medical Sciences. One thousand one hundred and eighty students were selected by convenience sampling. The English version of the MPAI questionnaire was translated into Persian with the approach of Jones et al. (Challenges in language, culture, and modality: Translating English measures into American Sign Language. Nurs Res 2006; 55: 75-81. Its reliability was tested by Cronbach′s alpha and its dimensionality validity was evaluated using Pearson correlation coefficients with other measures of mobile phone use and IAT. Construct validity was evaluated using Exploratory subscale analysis. Results: Cronbach′s alpha of 0.86 was obtained for total PMPAS, for subscale1 (eight items was 0.84, for subscale 2 (five items was 0.81 and for subscale 3 (two items was 0.77. There were significantly positive correlations between the score of PMPAS and IAT (r = 0.453, P < 0.001 and other measures of mobile phone use. Principal component subscale analysis yielded a three-subscale structure including: inability to control craving; feeling anxious and lost; mood improvement accounted for 60.57% of total variance. The results of discriminate validity showed that all the item′s correlations with related subscale were greater than 0.5 and correlations with unrelated subscale were less than 0.5. Conclusion: Considering lack of a valid and reliable questionnaire for measuring addiction to the mobile phone, PMPAS could be a suitable instrument for measuring mobile phone addiction in future research.

  12. Validity and reliability of the Persian version of mobile phone addiction scale.

    Science.gov (United States)

    Mazaheri, Maryam Amidi; Karbasi, Mojtaba

    2014-02-01

    With regard to large number of mobile users especially among college students in Iran, addiction to mobile phone is attracting increasing concern. There is an urgent need for reliable and valid instrument to measure this phenomenon. This study examines validity and reliability of the Persian version of mobile phone addiction scale (MPAIS) in college students. this methodological study was down in Isfahan University of Medical Sciences. One thousand one hundred and eighty students were selected by convenience sampling. The English version of the MPAI questionnaire was translated into Persian with the approach of Jones et al. (Challenges in language, culture, and modality: Translating English measures into American Sign Language. Nurs Res 2006; 55: 75-81). Its reliability was tested by Cronbach's alpha and its dimensionality validity was evaluated using Pearson correlation coefficients with other measures of mobile phone use and IAT. Construct validity was evaluated using Exploratory subscale analysis. Cronbach's alpha of 0.86 was obtained for total PMPAS, for subscale1 (eight items) was 0.84, for subscale 2 (five items) was 0.81 and for subscale 3 (two items) was 0.77. There were significantly positive correlations between the score of PMPAS and IAT (r = 0.453, P phone use. Principal component subscale analysis yielded a three-subscale structure including: inability to control craving; feeling anxious and lost; mood improvement accounted for 60.57% of total variance. The results of discriminate validity showed that all the item's correlations with related subscale were greater than 0.5 and correlations with unrelated subscale were less than 0.5. Considering lack of a valid and reliable questionnaire for measuring addiction to the mobile phone, PMPAS could be a suitable instrument for measuring mobile phone addiction in future research.

  13. Nurse managers' work life quality and their participation in knowledge management: a correlational study.

    Science.gov (United States)

    Hashemi Dehaghi, Zahra; Sheikhtaheri, Abbas; Dehnavi, Fariba

    2015-01-01

    The association between quality of work life and participation in knowledge management is unknown. This study aimed to discover the association between quality of work life of nurse managers and their participation in implementing knowledge management. This was a correlational study. All nurse managers (71 people) from 11 hospitals affiliated with the Social Security Organization in Tehran, Iran, were included. They were asked to rate their participation in knowledge management and their quality of work life. Data was gathered by a researcher-made questionnaire (May-June 2012). The questionnaire was validated by content and construct validity approaches. Cronbach's alpha was used to evaluate reliability. Finally, 50 questionnaires were analyzed. The answers were scored and analyzed using mean of scores, T-test, ANOVA (or nonparametric test, if appropriate), Pearson's correlation coefficient and linear regression. Nurse managers' performance to implement knowledge management strategies was moderate. A significant correlation was found between quality of work life of nurse managers and their participation in implementing knowledge management strategies (r = 0.82; P The strongest correlations were found between implementation of knowledge management and participation of nurse managers in decision making (r = 0.82; P knowledge management.

  14. Reliability and concurrent validity of the adapted Chinese version of Scoliosis Research Society-22 (SRS-22) questionnaire.

    Science.gov (United States)

    Cheung, Kenneth M C; Senkoylu, Alpaslan; Alanay, Ahmet; Genc, Yasemin; Lau, Sarah; Luk, Keith D

    2007-05-01

    Validation study to define validity and reliability of an adapted and translated questionnaire. Assessment of the concurrent validity and reliability of a Chinese version of SRS-22 outcome instrument. No valid health-related quality of life (HRQL) outcome instrument exists for patients with spinal deformity in Chinese. The modified SRS-22 questionnaire was proven to be an appropriate outcome instrument in English, and has already been translated and validated in several other languages. The English version of the SRS-22 questionnaire was adapted to Chinese according to the International Quality of Life Assessment Project guidelines. To assess reliability, 48 subjects with adolescent idiopathic scoliosis (mean age, 16.5 years) filled the questionnaire on 2 separate occasions (Group 1). To assess concurrent validity, 50 subjects (mean age, 21 years) filled in the same questionnaire and a previously validated Chinese version of the Short Form-36 (SF36) questionnaire (Group 2). Internal consistency, reproducibility and concurrent validity were determined with Cronbach's alpha coefficient, interclass correlation coefficient and Pearson correlation coefficient, respectively. Cronbach's alpha coefficient for the 4 major domains (function/activity, pain, self-image/appearance and mental health) were high. Intraclass correlation was also excellent for all domains. For concurrent validity, excellent correlation was found in 1 domain, good in 12 domains, moderate in 3 domains, and poor in 1 domain of the 17 relevant domains. Both cultural adaptation and linguistic translation are essential in any attempt to use a HRQL questionnaire across cultures. The Chinese version of the SRS-22 outcome instrument has satisfactory internal consistency and excellent reproducibility. It is ready for use in clinical studies on idiopathic scoliosis in Chinese-speaking societies.

  15. On the insignificance of Herschel's sunspot correlation

    Science.gov (United States)

    Love, Jeffrey J.

    2013-08-01

    We examine William Herschel's hypothesis that solar-cycle variation of the Sun's irradiance has a modulating effect on the Earth's climate and that this is, specifically, manifested as an anticorrelation between sunspot number and the market price of wheat. Since Herschel first proposed his hypothesis in 1801, it has been regarded with both interest and skepticism. Recently, reports have been published that either support Herschel's hypothesis or rely on its validity. As a test of Herschel's hypothesis, we seek to reject a null hypothesis of a statistically random correlation between historical sunspot numbers, wheat prices in London and the United States, and wheat farm yields in the United States. We employ binary-correlation, Pearson-correlation, and frequency-domain methods. We test our methods using a historical geomagnetic activity index, well known to be causally correlated with sunspot number. As expected, the measured correlation between sunspot number and geomagnetic activity would be an unlikely realization of random data; the correlation is "statistically significant." On the other hand, measured correlations between sunspot number and wheat price and wheat yield data would be very likely realizations of random data; these correlations are "insignificant." Therefore, Herschel's hypothesis must be regarded with skepticism. We compare and contrast our results with those of other researchers. We discuss procedures for evaluating hypotheses that are formulated from historical data.

  16. Validity and reliability of the Baecke questionnaire for the evaluation of habitual physical activity among people living with HIV/AIDS

    Directory of Open Access Journals (Sweden)

    Florindo Alex Antonio

    2006-01-01

    Full Text Available This study evaluates the validity and reliability of the Baecke questionnaire on habitual physical activity when applied to a population of HIV/AIDS subjects. Validity was determined by comparing measurements for 30 subjects of peak oxygen uptake, peak workload, and energy expenditure with scores for occupational physical activity (OPA, physical exercise in leisure (PEL, leisure and locomotion activities (LLA, and total score (TS. Reliability was determined by testing and retesting 29 subjects at intervals of 15-30 days. Validity was evaluated with the Pearson correlation and reliability analyses were done using the intraclass correlation, paired Student t-test, and Bland-Altman methods. Peak VO2 and peak workload had significant correlation with PEL (r = 0.41; r = 0.43; respectively. Energy expenditure had a significant correlation with OPA (r = 0.64. The intraclass coefficients were 0.70 or more for OPA, PEL and TS. There was no difference in OPA, PEL, LLA and TS between the two evaluations. The Bland-Altman methods showed that there was good agreement between the measurements for all habitual physical activities scores. Results show that the Baecke questionnaire is valid for the evaluation of habitual physical activity among people living with HIV/AIDS.

  17. Adherence to treatment for diabetes mellitus: validation of instruments for oral antidiabetics and insulin.

    Science.gov (United States)

    Boas, Lilian Cristiane Gomes-Villas; Lima, Maria Luisa Soares Almeida Pedroso de; Pace, Ana Emilia

    2014-01-01

    to verify the face validity, criterion-related validity and the reliability of two distinct forms of presentation of the instrument Measurement of Adherence to Treatment, one being for ascertaining the adherence to the use of oral antidiabetics and the other for adherence to the use of insulin, as well as to assess differences in adherence between these two modes of drug therapy. a methodological study undertaken with 90 adults with Type 2 Diabetes Mellitus. The criterion-related validity was verified using the Receiver Operating Characteristic curves; and for the reliability, the researchers calculated the Cronbach alpha coefficient, the item-total correlation, and the Pearson correlation coefficient. the oral antidiabetics and the other showed sensitivity of 0.84, specificity of 0.35 and a Cronbach correlation coefficient of 0.84. For the adherence to the use of insulin, the values found were, respectively, 0.60, 0.21 and 0.68. A statistically significant difference was found between the final scores of the two forms of the instrument, indicating greater adherence to the use of insulin than to oral antidiabetics. it is concluded that the two forms of the Measurement of Adherence to Treatment instrument are reliable and should be used to evaluate adherence to drug treatment among people with diabetes mellitus.

  18. Validation and reliability of the Baecke questionnaire for the evaluation of habitual physical activity in adult men

    Directory of Open Access Journals (Sweden)

    Alex Antonio Florindo

    2003-06-01

    Full Text Available The aim of this study was to verify validity and reliability of the scores for physical exercise in leisure (PEL, leisure and locomotion activities (LLA, and total score (TS of the Baecke habitual physical activity questionnaire in adult males. Twenty-one students of Physical Education were evaluated. For validation, the maximum oxygen uptake (O2max and the decrease of the heart rate in percentile (%DHR were measured through the Cooper's 12-minute walk or run test, and an annual index of physical exercise (IPE, and a week index of locomotion activities (ILA. The reliability was verified through test-retest with interval of 45 days. The Pearson correlation coefficient, and partial correlation adjusted for age and body mass index were used for validation. The intraclass correlation and paired t-test were used for reliability. The results indicated that %DHR was correlated with LLA and TS (r = 0.47 and p = 0.030; r = 0.48 and p = 0.027, respectively. IPE was correlated with PEL and TS (r = 0.56 and p = 0.008; r = 0.46 and p = 0.036, respectively. ILA was correlated with LLA and TS (r = 0.64 and p = 0.002 and r = 0.51 and p = 0.017, respectively. There was no significant difference in PEL, LLA and TS means in test-retest. The intraclass correlations were r = 0.69; r = 0.80 and r = 0.77, respectively for PEL, LLA and TS. In conclusion, the Baecke questionnaire is valid and reliable to measure habitual physical activity in Brazilian adult men.

  19. Statistical analysis of latent generalized correlation matrix estimation in transelliptical distribution.

    Science.gov (United States)

    Han, Fang; Liu, Han

    2017-02-01

    Correlation matrix plays a key role in many multivariate methods (e.g., graphical model estimation and factor analysis). The current state-of-the-art in estimating large correlation matrices focuses on the use of Pearson's sample correlation matrix. Although Pearson's sample correlation matrix enjoys various good properties under Gaussian models, its not an effective estimator when facing heavy-tail distributions with possible outliers. As a robust alternative, Han and Liu (2013b) advocated the use of a transformed version of the Kendall's tau sample correlation matrix in estimating high dimensional latent generalized correlation matrix under the transelliptical distribution family (or elliptical copula). The transelliptical family assumes that after unspecified marginal monotone transformations, the data follow an elliptical distribution. In this paper, we study the theoretical properties of the Kendall's tau sample correlation matrix and its transformed version proposed in Han and Liu (2013b) for estimating the population Kendall's tau correlation matrix and the latent Pearson's correlation matrix under both spectral and restricted spectral norms. With regard to the spectral norm, we highlight the role of "effective rank" in quantifying the rate of convergence. With regard to the restricted spectral norm, we for the first time present a "sign subgaussian condition" which is sufficient to guarantee that the rank-based correlation matrix estimator attains the optimal rate of convergence. In both cases, we do not need any moment condition.

  20. Validation of the Inventaire du Milieu Familial Questionnaire (French version of the Infant/Toddler HOME) into the Brazilian Portuguese language.

    Science.gov (United States)

    Sudbrack, Simone; Barbosa, Fernanda P; Mattiello, Rita; Booij, Linda; Estorgato, Geovana R; Dutra, Moisés S; Assunção, Fabiana D de; Nunes, Magda L

    2018-04-22

    To validate the Brazilian Portuguese version of the Family Environment Assessment questionnaire (Inventaire du Milieu Familial). The validation process was carried out in two stages. First, translation and back-translation were performed, and in the second phase, the questionnaire was applied in 72 families of children between 0 and 24 months for the validation process. The tool consists of the following domains: mother's communication ability; behavior; organization of the physical and temporal environment; collection/quantity of toys; maternal attitude of constant attention toward her baby; diversification of stimuli; baby's behavior. The following was performed for the scale validation: 1 - content analysis (judgment); 2 - construct analysis (factorial analysis - Kaiser-Meyer-Olkin, Bartlett, and Pearson's correlation tests); 3 - criterion analysis (calculation of Cronbach's alpha coefficient, intraclass correlations, and split-half correlations). The mean age of the children was 9±6.7 months, and of these, 35 (48.6%) were males. Most correlations between items and domains were significant. In the factorial analysis of the scale, Kaiser-Meyer-Olkin values were 0.76, Bartlett's test showed a p-value<0.001, and correlation between items and domains showed a p-value<0.01. Regarding the validity, Cronbach's alpha was 0.92 (95% CI: 0.89-0.94). The intraclass correlation among the evaluators was 0.97 (0.96-0.98) and split-half correlations, r: 0.60, with p<0.01. The Portuguese version of the Inventaire du Milieu Familial showed good to excellent performance regarding the assessed psychometric properties. Copyright © 2018. Published by Elsevier Editora Ltda.

  1. Validation of the Postgraduate Hospital Educational Environment Measure (PHEEM) in a sample of 731 Greek residents.

    Science.gov (United States)

    Koutsogiannou, Persa; Dimoliatis, Ioannis D K; Mavridis, Dimitris; Bellos, Stefanos; Karathanos, Vassilis; Jelastopulu, Eleni

    2015-11-30

    The Greek version of the Postgraduate Hospital Educational Environment Measure (PHEEM) was evaluated to determine its psychometric properties, i.e., validity, internal consistency, sensitivity and responsiveness to be used for measuring the learning environment in Greek hospitals. The PHEEM was administered to Greek hospital residents. Internal consistency was measured using Cronbach's alpha. Root Mean Square Error of Approximation (RMSEA) was used to evaluate the fit of Structural Equation Models. Content validity was addressed by the original study. Construct validity was tested using confirmatory (to test the set of underlying dimensions suggested by the original study) and exploratory (to explore the dimensions needed to explain the variability of the given answers) factor analysis using Varimax rotation. Convergent validity was calculated by Pearson's correlation coefficient regarding the participant's PHEEM score and participant's overall satisfaction score of the added item "Overall, I am very satisfied with my specialization in this post". Sensitivity was checked by comparing good versus poor aspects of the educational environment and by satisfied versus unsatisfied participants. A total of 731 residents from 83 hospitals and 41 prefectures responded to the PHEEM. The original three-factor model didn't fit better compared to one factor model that is accounting for 32% of the variance. Cronbach's α was 0.933 when assuming one-factor model. Using a three-factor model (autonomy, teaching, social support), Cronbach's α were 0.815 (expected 0.830), 0.908 (0.839), 0.734 (0.793), respectively. The three-factor model gave an RMSEA value of 0.074 (90% confidence interval 0.071, 0.076), suggesting a fair fit. Pearson's correlation coefficient between total PHEEM and global satisfaction was 0.765. Mean question scores ranged from 19.0 (very poor) to 73.7 (very good), and mean participant scores from 5.5 (very unsatisfied) to 96.5 (very satisfied). The Greek version

  2. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    Science.gov (United States)

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  3. External Validation of a Case-Mix Adjustment Model for the Standardized Reporting of 30-Day Stroke Mortality Rates in China.

    Directory of Open Access Journals (Sweden)

    Ping Yu

    Full Text Available A case-mix adjustment model has been developed and externally validated, demonstrating promise. However, the model has not been thoroughly tested among populations in China. In our study, we evaluated the performance of the model in Chinese patients with acute stroke.The case-mix adjustment model A includes items on age, presence of atrial fibrillation on admission, National Institutes of Health Stroke Severity Scale (NIHSS score on admission, and stroke type. Model B is similar to Model A but includes only the consciousness component of the NIHSS score. Both model A and B were evaluated to predict 30-day mortality rates in 13,948 patients with acute stroke from the China National Stroke Registry. The discrimination of the models was quantified by c-statistic. Calibration was assessed using Pearson's correlation coefficient.The c-statistic of model A in our external validation cohort was 0.80 (95% confidence interval, 0.79-0.82, and the c-statistic of model B was 0.82 (95% confidence interval, 0.81-0.84. Excellent calibration was reported in the two models with Pearson's correlation coefficient (0.892 for model A, p<0.001; 0.927 for model B, p = 0.008.The case-mix adjustment model could be used to effectively predict 30-day mortality rates in Chinese patients with acute stroke.

  4. The development of a statistical procedure to correct the effects of restriction of range on validity coefficients

    Directory of Open Access Journals (Sweden)

    J. M. Scheepers

    1996-06-01

    Full Text Available In the validation of tests used for selection purposes, the obtained validity coefficients are invariably underestimates of the true validities, due to explicit and implicit selection in respect of the relevant variables. Both explicit and implicit selection leads to restriction of range of the relevant variables, and this in turn reduces the obtained validites. A formal proof for this is given. A number of researchers have developed formulae for correcting sample validities in order to get better estimates of the true validities (Pearson/ 1903; Thorndike, 1949; Gulliksen, 1950; Rydberg, 1962 and Lord & Novick, 1968. It is, however, virtually impossible to obtain a complete view of the problem of restriction of range in this way. In the present paper a different approach has been followed: Population correlations have been computed for various degrees of truncation of the explicit selection variable. This has been done for population correlations ranging from 0,10 to 0,99. A graphical display, indicating the shrinkage of the population correlations for various truncation ratios, has been prepared. Opsomming In die geldigheidsbepaling van toetse wat vir keuringsdoeleindes gebruik word, is die verkree geldigheidskoeffisiente sender uitsondering onderskattings van die ware geldighede as gevolg van eksplisiete en implisiete keuring ten opsigte van die tersaaklike veranderlikes. Sowel eksplisiete as implisiete keuring lei tot inperking van die variasiewydte van die relevante veranderiikes, en dit reduseer om die beurt weer die verkree geldighede. 'n Formele bewys hiervoor word in die referaat gegee. 'n Aantal navorsers het formules ontwikkel om steekproefgeldighede te korrigeer ten einde beter beramings van die ware geldighede te verkry (Pearson/ 1903; horndike, 1949: Gulliksen, 1950; Rygberg, 1962 en Lord & Novick, 1968. Dit is egter bykans onmoontlik om op hierdie wyse 'n geheelbeeld van die probleem van inperking van variasiewydte te vorm. In die

  5. Reproducibility and Validity of a Food Frequency Questionnaire for Assessing Dietary Consumption via the Dietary Pattern Method in a Chinese Rural Population.

    Science.gov (United States)

    Liu, Xudong; Wang, Xiaorong; Lin, Sihao; Song, Qingkun; Lao, Xiangqian; Yu, Ignatius Tak-Sun

    2015-01-01

    This study was conducted to assess the reproducibility and validity of a food frequency questionnaire (FFQ) that was developed to assess the overall dietary consumption via dietary pattern method in a rural population in southwest China. A total of 179 participants aged between 40 and 70 years old were included in this study. Participants administered FFQ at baseline (FFQ1) and one year later (FFQ2) to assess the reproducibility. Six 3-day 24-hour recalls (24HRs) were completed between the administrations of two FFQs to determine the validity. Dietary patterns from three separate dietary sources were derived by using principle component factor analysis. Comparisons between dietary pattern scores were made by using Pearson or intraclass correlation coefficient, cross-classification analysis, weighted kappa (κ) statistic and Bland-Altman analysis. The de-attenuated method was adopted to correct the monthly and seasonally variation and the partial correlation analysis was used correct the influence by total energy intake. Two major dietary factors, labeled as prudent pattern and processed food pattern, were identified. The prudent pattern was characterized by higher factor loadings of wheat, rice, fresh vegetables, bean products, nuts, red meat, white meat and fresh eggs; and the processed food pattern was characterized by higher factor loadings of pickled vegetables, preserved vegetables and salted meat. Between Two FFQs, intraclass correlation coefficients were 0.57 for prudent pattern and 0.55 for processed food pattern, partial Pearson correlation coefficients were 0.51 for the prudent pattern and 0.56 for the processed food pattern; weighted κ statistic ranged from 0.45 (for the prudent pattern) to 0.56 (for the processed food pattern). Between FFQs and 24HRs, de-attenuated correlation coefficients ranged from 0.54 to 0.78 for the prudent pattern and from 0.55 to 0.61 for the processed food pattern; partial Pearson correlation coefficients ranged from 0.41 to 0

  6. Reproducibility and Validity of a Food Frequency Questionnaire for Assessing Dietary Consumption via the Dietary Pattern Method in a Chinese Rural Population.

    Directory of Open Access Journals (Sweden)

    Xudong Liu

    Full Text Available This study was conducted to assess the reproducibility and validity of a food frequency questionnaire (FFQ that was developed to assess the overall dietary consumption via dietary pattern method in a rural population in southwest China.A total of 179 participants aged between 40 and 70 years old were included in this study. Participants administered FFQ at baseline (FFQ1 and one year later (FFQ2 to assess the reproducibility. Six 3-day 24-hour recalls (24HRs were completed between the administrations of two FFQs to determine the validity. Dietary patterns from three separate dietary sources were derived by using principle component factor analysis. Comparisons between dietary pattern scores were made by using Pearson or intraclass correlation coefficient, cross-classification analysis, weighted kappa (κ statistic and Bland-Altman analysis. The de-attenuated method was adopted to correct the monthly and seasonally variation and the partial correlation analysis was used correct the influence by total energy intake.Two major dietary factors, labeled as prudent pattern and processed food pattern, were identified. The prudent pattern was characterized by higher factor loadings of wheat, rice, fresh vegetables, bean products, nuts, red meat, white meat and fresh eggs; and the processed food pattern was characterized by higher factor loadings of pickled vegetables, preserved vegetables and salted meat. Between Two FFQs, intraclass correlation coefficients were 0.57 for prudent pattern and 0.55 for processed food pattern, partial Pearson correlation coefficients were 0.51 for the prudent pattern and 0.56 for the processed food pattern; weighted κ statistic ranged from 0.45 (for the prudent pattern to 0.56 (for the processed food pattern. Between FFQs and 24HRs, de-attenuated correlation coefficients ranged from 0.54 to 0.78 for the prudent pattern and from 0.55 to 0.61 for the processed food pattern; partial Pearson correlation coefficients ranged

  7. Validity and Reliability of Perinatal Biomarkers after Storage as Dry Blood Spots on Paper

    Science.gov (United States)

    Mihalopoulos, Nicole L.; Phillips, Terry M.; Slater, Hillarie; Thomson, J. Anne; Varner, Michael W.; Moyer-Mileur, Laurie J.

    2013-01-01

    Ojective To validate use of chip-based immunoaffinity capillary electrophoresis on dry blood spot samples (DBSS) to measure obesity-related cytokines. Methods Chip-based immunoaffinity capillary electrophoresis was used to measure adiponectin, leptin and insulin in serum and DBSS in pregnant women, cord blood, and infant heelstick at birth and 6 weeks. Concordance of measurements was determined with Pearson's correlation. Results We report high concordance between results obtained from serum and DBSS with the exception of cord blood specimens. Conclusions Ease of sample collection and storage makes DBSS an optimal method for use in studies involving neonates and young children. PMID:21735507

  8. Converting three general-cognitive function scales into Persian and assessment of their validity and reliability

    Directory of Open Access Journals (Sweden)

    Payam Moin

    2011-01-01

    Full Text Available Objectives: Glasgow Outcome Scale Extended (GOSE, Galveston Amnesia and orientation Test (GOAT and Disability Rating Scale (DRS are three popular outcome measure tools used principally in traumatic brain injury (TBI patients. We conducted this study to provide a Farsi version of these outcome scales for use in Iran. Methods: Following a comprehensive literature review, Farsi transcripts were prepared by "forward-backward" translation and reviewed by subject experts. After a pretest on a few patients, the final versions were obtained. 38 patients with closed head injury were interviewed simultaneously by two interviewers. Main statistics used to assess validity and reliability included "Factor analysis" for construct validity, Cronbach′s alpha for internal consistency, and Pearson Correlation and Kappa Coefficient for inter-rater agreement. Results: Factor analysis for Farsi-GOAT (FGOAT revealed 5 independent factors with a total distribution variance of 80.2%. For Farsi-DRS (FDRS, 3 independent factors were found with a 92.3% variance. The Cronbach′s alpha (95% confidence interval was 0.84 (0.763- 0.919 and 0.91 (0.901-0.919 for FGOAT and FDRS, respectively. Pearson Correlation between total scores of two raters was 0.98 and 0.97 for FGOAT and FDRS, in order. Kappa coefficient (95% CI between outcome rankings of raters was 0.73 (0.618-0.852 and 0.68 (0.594-0.770 for FGOAT and FDRS, respectively. As for Farsi-GOSE scale, Kappa value was 0.4 (0.285-0.507 for 8-level outcome ranking and improved to 0.7 (0.585-0.817 for 5-level scale. We found a good correlation between FDRS and FGOSE predicted prognoses (Spearman′s rho= 0.74, 95% CI: 0.676-0.802. Conclusions: FDRS and FGOAT had appropriate validity and reliability. The 8-level outcome FGOSE scale disclosed a low inter-rater agreement, but a suitable observer agreement was achieved when the 5-level outcome was applied.

  9. Brazilian Portuguese version of the Revised Fibromyalgia Impact Questionnaire (FIQR-Br): cross-cultural validation, reliability, and construct and structural validation.

    Science.gov (United States)

    Lupi, Jaqueline Basilio; Carvalho de Abreu, Daniela Cristina; Ferreira, Mariana Candido; Oliveira, Renê Donizeti Ribeiro de; Chaves, Thais Cristina

    2017-08-01

    This study aimed to culturally adapt and validate the Revised Fibromyalgia Impact Questionnaire (FIQR) to Brazilian Portuguese, by the use of analysis of internal consistency, reliability, and construct and structural validity. A total of 100 female patients with fibromyalgia participated in the validation process of the Brazilian Portuguese version of the FIQR (FIQR-Br).The intraclass correlation coefficient (ICC) was used for statistical analysis of reliability (test-retest), Cronbach's alpha for internal consistency, Pearson's rank correlation for construct validity, and confirmatory factor analysis (CFA) for structural validity. It was verified excellent levels of reliability, with ICC greater than 0.75 for all questions and domains of the FIQR-Br. For internal consistency, alpha values greater than 0.70 for the items and domains of the questionnaire were observed. Moderate (0.40  0.70) correlations were observed for the scores of domains and total score between the FIQR-Br and FIQ-Br. The structure of the three domains of the FIQR-Br was confirmed by CFA. The results of this study suggest that that the FIQR-Br is a reliable and valid instrument for assessing fibromyalgia-related impact, and supports its use in clinical settings and research. The structure of the three domains of the FIQR-Br was also confirmed. Implications for Rehabilitation Fibromyalgia is a chronic musculoskeletal disorder characterized by widespread and diffuse pain, fatigue, sleep disturbances, and depression. The disease significantly impairs patients' quality of life and can be highly disabling. To be used in multicenter research efforts, the Revised Fibromyalgia Impact Questionnaire (FIQR) must be cross-culturally validated and psychometrically tested. This paper will make available a new version of the FIQR-Br since another version already exists, but there are concerns about its measurement properties. The availability of an instrument adapted to and validated for Brazilian

  10. Portuguese Children's Sleep Habits Questionnaire -validation and cross-cultural comparison

    Directory of Open Access Journals (Sweden)

    Filipe Gloria Silva

    2014-01-01

    Full Text Available OBJECTIVE: To validate the Portuguese version of the Children's Sleep Habits Questionnaire (CSHQ-PT and compare it to the versions from other countries. METHODS: The questionnaire was previously adapted to the Portuguese language according to international guidelines. 500 questionnaires were delivered to the parents of a Portuguese community sample of children aged 2 to 10 years old. 370 (74% valid questionnaires were obtained, 55 children met exclusion criteria and 315 entered in the validation study. RESULTS: The CSHQ-PT internal consistency (Cronbach's α was 0.78 for the total scale and ranged from 0.44 to 0.74 for subscales. The test-retest reliability for subscales (Pearson's cor-relations, n=58 ranged from 0.59 to 0.85. Our data did not adjust to the original 8 domains structure in Confirmatory Factor Analysis but the Exploratory Factor Analysis extracted 5 factors that have correspondence to CSHQ subscales. CONCLUSION: The CSHQ-PT evidenced psychometric properties that are comparable to the versions from other countries and adequate for the screening of sleep disturbances in children from 2 to 10 years old.

  11. Correlations between Optical Variability and Physical Parameters of ...

    Indian Academy of Sciences (India)

    ever, the predicted positive correlation between variability and black hole mass seems to be ... Introduction. Variability is one of the .... Accompanied by the slope b_X and y-axis intercept value a_X, the Pearson product- moment correlation ...

  12. Functional connectivity and structural covariance between regions of interest can be measured more accurately using multivariate distance correlation.

    Science.gov (United States)

    Geerligs, Linda; Cam-Can; Henson, Richard N

    2016-07-15

    Studies of brain-wide functional connectivity or structural covariance typically use measures like the Pearson correlation coefficient, applied to data that have been averaged across voxels within regions of interest (ROIs). However, averaging across voxels may result in biased connectivity estimates when there is inhomogeneity within those ROIs, e.g., sub-regions that exhibit different patterns of functional connectivity or structural covariance. Here, we propose a new measure based on "distance correlation"; a test of multivariate dependence of high dimensional vectors, which allows for both linear and non-linear dependencies. We used simulations to show how distance correlation out-performs Pearson correlation in the face of inhomogeneous ROIs. To evaluate this new measure on real data, we use resting-state fMRI scans and T1 structural scans from 2 sessions on each of 214 participants from the Cambridge Centre for Ageing & Neuroscience (Cam-CAN) project. Pearson correlation and distance correlation showed similar average connectivity patterns, for both functional connectivity and structural covariance. Nevertheless, distance correlation was shown to be 1) more reliable across sessions, 2) more similar across participants, and 3) more robust to different sets of ROIs. Moreover, we found that the similarity between functional connectivity and structural covariance estimates was higher for distance correlation compared to Pearson correlation. We also explored the relative effects of different preprocessing options and motion artefacts on functional connectivity. Because distance correlation is easy to implement and fast to compute, it is a promising alternative to Pearson correlations for investigating ROI-based brain-wide connectivity patterns, for functional as well as structural data. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  13. The Zarit Caregiver Burden Interview Short Form (ZBI-12 in spouses of Veterans with Chronic Spinal Cord Injury, Validity and Reliability of the Persian Version

    Directory of Open Access Journals (Sweden)

    Mohammad T. Rajabi Mashhadi

    2015-01-01

    Full Text Available Background:  To test the psychometric properties of the Persian version of Zarit Burden Interview (ZBI-12 in the Iranian opulation.  Methods: After translating and cultural adaptation of the questionnaire into Persian, 100 caregiver spouses of Iran-Iraq war (1980-88 veterans with chronic spinal cord injury who live in the city of Mashhad, Iran, invited to participate in the study. The Persian version of ZBI-12 accompanied with the Persian SF-36 was completed by the caregivers to test validity of the Persian ZBI-12.A Pearson`s correlation coefficient was calculated for validity testing.In order to assess reliability of the Persian ZBI-12, we administered the ZBI-12 randomly in 48 caregiver spouses again 3 days later. Results:  Generally, the internal consistency of the questionnaire was found to be strong (Cronbach’s alpha 0.77. Intercorrelationmatrix between the different domains of ZBI-12 at test-retest was 0.78. The results revealed that majority of questions the Persian ZBI_12 have a significant correlation to each other. In terms of validity, our results showed that there is significant correlations between some domains of the Persian version the Short Form Health Survey -36 with the Persian Zarit Burden Interview such as Q1 with Role Physical (P=0.03,General Health (P=0.034,Social Functional (0.037, Mental Health (0.023 and Q3 with Physical Function (P=0.001,Viltality (0.002, Socil Function (0.001.  Conclusions:  Our findings suggest that the Zarit Burden Interview Persian version is both a valid and reliable instrument for measuring the burden of caregivers of individuals with chronic spinal cord injury.

  14. Validity of Yin-Yang temperament in Sasang Personality Questionnaire.

    Science.gov (United States)

    Hwang, Bo Kyung; Yoon, Yeo-Jin; Han, Sang Yun; Lee, Soo Jin; Chae, Han

    2018-03-01

    The Yin-Yang is a pivotal concept of traditional East-Asian medicine, however the stability of Yin-Yang temperament in Sasang Personality Questionnaire (SPQ) over time has not been extensively studied. The purpose of this study was to examine the test-retest validity of SPQ with a large number of participants. SPQ test was conducted two times with three months interval in 247 Korean university students. The structural validity of first SPQ data was examined with Factor analysis and Cronbach's alpha, and the correlation between first and second measure of SPQ was attested with Pearson's correlation. Yang, Uncertain and Yin temperament groups were determined with SPQ total scores, and agreement of temperament group clustering between first and second measures were analyzed with Cohen's Kappa. Three subscales of SPQ explained 55.25% of total variances, and internal consistency of SPQ total score was 0.772. The correlation coefficient between first and second measures of SPQ were 0.851 and 0.888 in male and female, respectively, and the agreement of first and second Yin-Yang temperament group clustering as Cohen's Kappa was 0.536 for male and 0.637 for female. The repeatability of SPQ measuring Yin-Yang temperament at three months of interval was found to be satisfactory. The SPQ would be a reliable clinical measure for the biopsychological studies of traditional East-Asian medicine.

  15. Validation of the Resilience Scale for Adolescents in Norwegian adolescents 13-18 years.

    Science.gov (United States)

    Moksnes, Unni K; Haugan, Gørill

    2018-03-01

    Resilience is seen as a vital resource for coping and mental health in adolescents. However, there is no universally accepted theory or definition of resilience, leading to considerable challenges regarding how to operationalise and measure this construct. The study aimed at providing further knowledge of the psychometric properties (dimensionality, construct validity and internal consistency) of the 28-item version of the Resilience Scale for Adolescents (READ) in N = 1183 Norwegian adolescents, 13-18 years old. Dimensionality of READ was tested using confirmatory factor analysis (CFA). Convergent validity and reliability were tested using Pearson's correlation analysis, Cronbach's alpha and composite reliability. The CFA supported a modified, 20-item, five-factor structure with high reliability, supporting the dimensionality and internal consistency of the instrument. Convergent validity was confirmed where all factors correlated in expected directions with measures of sense of coherence, self-esteem, stress and depression. The psychometric properties of the READ need to be further evaluated in adolescents; however, the results indicate that a modified 20-item version of READ is adequate for assessing resilience in the present sample of Norwegian adolescents. © 2017 Nordic College of Caring Science.

  16. Food Frequency Questionnaire to Determine the Intake of Vitamin C: A Pilot Validation Study

    Directory of Open Access Journals (Sweden)

    Santosh Holenarasipur Nagesh

    2017-06-01

    Full Text Available Background and Aims: The aim of this study was to validate a food frequency questionnaire (FFQ specific to diabetic population wherein the frequency of intake of vitamin C would be examined. Material and Methods: The study is registered with Clinical Trial Registry of India (CTRI with CTRI number CTRI/2016/03/006764. The FFQ was validated against intakes derived from a 24 Hour Dietary Recall (24 DR. 50 subjects were chosen and a FFQ with 24-hour dietary recall was done. The FFQ had a list of commonly used food items. The vitamin C yield from each food item was precalculated. Result and conclusion: Strong correlations between the FFQ and 24 dietary recall were observed for all vitamin C containing food list (Pearson Correlation Coefficient r = 0.997. The p value was significant between the FFQ and 24Hour dietary recall (p = 0.028. Cross classification analysis showed uniform classification of the respondents and there was no misclassification into quartiles. This pilot study showed promising validation evidence for the use of this FFQ, which focuses vitamin C intake in patients with type 2 Diabetes Mellitus, as a screening tool in clinical and research settings.

  17. Reproducibility and Validity of a Food Frequency Questionnaire Designed to Assess Diet in Children Aged 4-5 Years.

    Science.gov (United States)

    Vioque, Jesus; Gimenez-Monzo, Daniel; Navarrete-Muñoz, Eva Maria; Garcia-de-la-Hera, Manuela; Gonzalez-Palacios, Sandra; Rebagliato, Marisa; Ballester, Ferran; Murcia, Mario; Iñiguez, Carmen; Granado, Fernando

    2016-01-01

    The food frequency questionnaire (FFQ) is the most efficient and cost-effective method to investigate the relationship between usual diet and disease in epidemiologic studies. Although FFQs have been validated in many adult populations worldwide, the number of valid FFQ in preschool children is very scarce. The aim of this study was to evaluate the reproducibility and validity of a semi-quantitative FFQ designed for children aged 4 to 5 years. In this study, we have included 169 children aged 4-5 years from the INMA project in Valencia, a population-based prospective cohort study of mothers and children in Spain. The 105-items FFQ was administered twice to the parents or care-givers of children over a 9-month period. Reproducibility was explored by comparing intake of nutrients by the FFQs, while validity was examined by comparing the nutrient values from the FFQs with the average nutrient values of three 24 hour dietary recall (24hDR) taken in the period, and also, with the concentration in blood specimens for several vitamins (carotenoids, folate, vitamin B12, vitamin C and α-tocopherol). Pearson correlation coefficients and de-attenuated correlation coefficients were calculated and we also evaluated misclassification by quintile distribution. All correlation coefficients for reproducibility for nutrients and major food groups were statistically significant; the average correlation coefficients for daily intake were 0.43 for food groups and 0.41 for nutrients. The average correlation coefficients for validity for daily intakes against 24hDR was r = 0.30, and the average for de-attenuated correlation coefficients was r = 0.44. When evaluating validity against the blood concentration of vitamins, statistically significant correlations were observed for vitamin C (0.35), lycopene (0.31), β-Cryptoxantin (0.40), and vitamin E (0.29); the average of correlation coefficients was r = 0.21. Despite some low to moderate correlations for reproducibility and validity

  18. Validation of a measurement tool for self-assessment of teamwork in intensive care.

    Science.gov (United States)

    Weller, J; Shulruf, B; Torrie, J; Frengley, R; Boyd, M; Paul, A; Yee, B; Dzendrowskyj, P

    2013-09-01

    Teamwork is an important contributor to patient safety and a validated teamwork measurement tool could help healthcare teams identify areas for improvement and measure progress. We explored the psychometric properties of a teamwork measurement tool when used for self-assessment. We hypothesized that the tool had a valid factor structure and that scores from participants and external assessors would correlate. Forty intensive care teams (one doctor, three nurses) participated in four simulated emergencies, and each independently rated their team's performance at the end of each case using the teamwork measurement tool, without prior training in the use of the tool. We used exploratory factor analysis (EFA) and confirmatory factor analysis (CFA), and compared factor structure between participants and external assessors (using previously reported data). Scores from participants and external assessors were compared using Pearson's correlation coefficient. EFA demonstrated items loaded onto three distinct factors which were supported by the CFA. We found significant correlations between external and participant scores for overall teamwork scores and the three factors. Participants agreed with external assessors on the ranking of overall team performance but scored themselves significantly higher than external assessors. The teamwork measurement tool has a valid structure when used for self-assessment. Participant and external assessor scores correlated significantly, suggesting that participants could discriminate between different levels of performance, although leniency in self-assessed scores indicated the need for calibration. This tool could help structure reflection on teamwork and potentially facilitate self-directed, workplace-based improvement in teamwork.

  19. Psychometric properties of the Revised Fibromyalgia Impact Questionnaire (FIQR – a contribution to the Portuguese validation of the scale

    Directory of Open Access Journals (Sweden)

    Carlos Costa

    2016-07-01

    Full Text Available Background: Fibromyalgia (FM remains a relatively misunderstood and clinically challenging condition that impact significantly in the individual´s life, impairing global functioning and diminishing quality of life. Management is complex and frequently unsatisfactory, requiring personal tailoring and adaptation of interventions according to the fluctuations of the disease manifestations and their response to therapy. The use of comprehensive and quantified assessment tools constitutes, therefore, an essential component of the management of patients with FM. The Revised Fibromyalgia Impact Questionnaire (FIQR is currently one of the most used and well validated instruments to assess functional (incapacity and global impact of FM and associated symptoms. Objectives: To translate to Portuguese the FIQR and to study its psychometric properties. Material and Methods: The total sample comprised 103 women with fibromyalgia, defined according to the established criteria for FM. A self-report battery composed by the Revised Fibromyalgia Impact Questionnaire (FIQR, the Portuguese version of Beck Depression Inventory-II (BDI-II and the Profile of Mood States (PoMS was administered. The FIQR was re-administered to twenty-four participants, six weeks after the first evaluation. Internal reliability was assessed through Cronbach’s alpha, corrected item-total score correlations and alpha if item deleted. Spearman and Pearson correlations along with repeated measures tests were computed to assess the temporal stability of the scale. Convergent and divergent validity were assessed via Spearman and Pearson correlations. Results: The FIQR demonstrated a good to very good internal consistency (from α = 0.87 to α = 0.94. All items correlated to a good degree (above 0.30 to the total score and contributed significantly to the overall reliability. Moreover, FIQR presented a good temporal stability (from r = .617 to r = .886, p ≤ .001 and favorable convergent and

  20. Development and Validity of a Scale of Perception of Velocity in Resistance Exercise

    Directory of Open Access Journals (Sweden)

    Iker J. Bautista

    2014-09-01

    Full Text Available This aims of this study were twofold; 1 to development a new scale of perceived velocity in the bench press exercise and 2 to examine the scales concurrent validity. Twenty one physically active males with mean ±SD age, height and weights of: 27.5 ± 4.7 years, 1.77 ± 0.07 m, and 79.8 ± 10.3 kg respectively, took part in the study. The criterion variable used to test the validity of the new scale was the mean execution velocity (Velreal of the bench press exercise. Three intensities (light loads [ 70% 1RM] were measured randomly during 5 days of testing. Perceived velocity (Velscale was measured immediately after each exercise set using the new scale. A positive linear correlation (r range = 0.69 to 0.81 was found in all three intensities, analyzed individually, between the Velreal and Velscale. Pearson correlations showed a greater frequency of scale use resulted higher correlation values (range r = 0.88 to 0.96. This study provides evidence of the concurrent validity of a new scale of perceived velocity in the bench press exercise in trained adult males. These results suggest the exercise intensity of the bench press can be quantified quickly and effective using this new scale of perceived velocity, particularly when training for maximum power.

  1. Correlation of bone quality in radiographic images with clinical bone quality classification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Woo; Huh, Kyung Hoe; Kim, Jeong Hwa; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul [Seoul National University, Seoul (Korea, Republic of); Park, Kwan Soo [Inje University, Seoul (Korea, Republic of)

    2006-03-15

    To investigate the validity of digital image processing on panoramic radiographs in estimating bone quality before endosseous dental implant installation by correlating bone quality in radiographic images with clinical bone quality classification. An experienced surgeon assessed and classified bone quality for implant sites with tactile sensation at the time of implant placement. Including fractal dimension eighteen morphologic features of trabecular pattern were examined in each anatomical sites on panoramic radiographs. Finally bone quality of 67 implant sites were evaluated in 42 patients. Pearson correlation analysis showed that three morphologic parameters had weak linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.276, -0.280, and -0.289, respectively (p<0.05). And other three morphologic parameters had obvious linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.346, -0.488, and -0.343 respectively (p<0.05). Fractal dimension also had a linear correlating with clinical bone quality classification with correlation coefficients -0.506 significantly (P<0.05). This study suggests that fractal and morphometric analysis using digital panoramic radiographs can be used to evaluate bone quality for implant recipient sites.

  2. Translation into Portuguese, cross-cultural adaptation and validation of "The European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire-Bone Metastases-22".

    Science.gov (United States)

    Miki-Rosário, Natália; Garcia Filho, Reynaldo Jesus; Garcia, Jairo Greco; Dini, Gal Moreira; Bottomley, Andrew; Chow, Edward; Sabino Neto, Miguel

    2016-07-01

    The aim of the present study was to conduct a cross-cultural adaptation (with translation into Brazilian Portuguese) and validation of the European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire-Bone Metastases-22 (EORTC QLQ-BM22). Ninety-five bone metastasis patients (31 men and 64 women, mean age 58.36±8.90 years) took part in the investigation. The translation guide of the EORTC was used to translate from English into Brazilian Portuguese and adapt the instrument culturally. The reliability and the face, content and construct validities were tested. Internal consistency was estimated using Cronbach's alpha for the total score, pain and functional subscales of the EORTC QLQ-BM22 (0.93, 0.86, 0.90). Reliability was analyzed by Pearson's correlation and intraclass correlation coefficients (ICCs). The correlations were higher than the recommended value of 0.75, which indicated good test-retest reliability. Construct validity was demonstrated by correlation with the questionnaire medical outcome study questionnaire 36-Item Short Form Survey (SF-36). It showed significant correlation between the fields of QLQ-BM22 and the SF-36 (P≤0.001). The EORTC QLQ-BM22 was translated into Brazilian Portuguese, was culturally adapted and was proven to be reliable, with face, content and construct validity.

  3. Rietveld refinement of Y2O3 using the pearson VII profile shape function

    International Nuclear Information System (INIS)

    Smrcok, L.

    1989-01-01

    Very good agreement between the observed and the calculated intensities was obtained using the Pearson VII profile shape function. The variable exponent m could be refined only in the damped iterations involving exclusively the profile parameters. Simultaneous refinement of the m with the positional and/or thermal parameters has led to large oscillations of the shifts of almost all parameters. Precision of the refined atomic coordinates is better than those from previously published Rietveld refinement and is comparable with single crystal results. The degree of serial correlation in residuals has been determined by the use of the Durbin-Watson d statistic. Normal probability plot based on δR i has been almost linear with the slope greater than one. The weighting scheme with w i = 1/y oi has proved to be good first approximation. (author)

  4. Performance of Distributed CFAR Processors in Pearson Distributed Clutter

    OpenAIRE

    Messali Zoubeida; Soltani Faouzi

    2007-01-01

    This paper deals with the distributed constant false alarm rate (CFAR) radar detection of targets embedded in heavy-tailed Pearson distributed clutter. In particular, we extend the results obtained for the cell averaging (CA), order statistics (OS), and censored mean level CMLD CFAR processors operating in positive alpha-stable (P&S) random variables to more general situations, specifically to the presence of interfering targets and distributed CFAR detectors. The receiver operating ...

  5. Development and Validation of a Semi-Quantitative Food Frequency Questionnaire to Assess Dietary Intake of Turkish School-Aged Children

    Directory of Open Access Journals (Sweden)

    Güneş Fatma Esra

    2016-06-01

    Full Text Available The aim of this study was to develop and validate a food frequency questionnaire (FFQ on the dietary intake of Turkish school-aged children. Fifty randomly selected students aged 7–12 from urban areas of Istanbul were included in this study. An FFQ, containing a list of 138 frequently consumed foods was developed. Dietary records (DRs including three days, and FFQs were collected during autumn and spring. Daily consumption of each food group was assessed and the nutrient compositions of diet were calculated. The Pearson correlation coefficient, weighted kappa, the Bland-Altman scatter plots between averages of the reported (FFQ and the references method (DR were used as validity coefficient.

  6. Cross-cultural adaptation, reliability and validity of the Turkish version of the Hospital for Special Surgery (HSS) Knee Score.

    Science.gov (United States)

    Narin, Selnur; Unver, Bayram; Bakırhan, Serkan; Bozan, Ozgür; Karatosun, Vasfi

    2014-01-01

    The purpose of this study was to adapt the English version of the Hospital for Special Surgery (HSS) knee score for use in a Turkish population and to evaluate its validity, reliability and cultural adaptation. Standard forward-back translation of the HSS knee score was performed and the Turkish version was applied in 73 patients. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Mini-Mental State Examination and sit-to-stand test were also performed and analyzed. Internal consistency reliability was tested using Cronbach's alpha. The intraclass correlation coefficient (ICC) was used to calculate the test-retest reliability at one-week intervals. Validity was assessed by calculating the Pearson correlation between the HSS, WOMAC and sit-to-stand test scores. The ICC ranged from 0.98 to 0.99 with high internal consistency (Cronbach's alpha: 0.87). The WOMAC score correlated with total HSS score (r: -0.80, p<0.001) and sit-to-stand score (r: 0.12, p: 0.312). The Turkish version of the HSS knee score is reliable and valid in evaluating the total knee arthroplasty in Turkish patients.

  7. Validation of the Leap Motion Controller using markered motion capture technology.

    Science.gov (United States)

    Smeragliuolo, Anna H; Hill, N Jeremy; Disla, Luis; Putrino, David

    2016-06-14

    The Leap Motion Controller (LMC) is a low-cost, markerless motion capture device that tracks hand, wrist and forearm position. Integration of this technology into healthcare applications has begun to occur rapidly, making validation of the LMC׳s data output an important research goal. Here, we perform a detailed evaluation of the kinematic data output from the LMC, and validate this output against gold-standard, markered motion capture technology. We instructed subjects to perform three clinically-relevant wrist (flexion/extension, radial/ulnar deviation) and forearm (pronation/supination) movements. The movements were simultaneously tracked using both the LMC and a marker-based motion capture system from Motion Analysis Corporation (MAC). Adjusting for known inconsistencies in the LMC sampling frequency, we compared simultaneously acquired LMC and MAC data by performing Pearson׳s correlation (r) and root mean square error (RMSE). Wrist flexion/extension and radial/ulnar deviation showed good overall agreement (r=0.95; RMSE=11.6°, and r=0.92; RMSE=12.4°, respectively) with the MAC system. However, when tracking forearm pronation/supination, there were serious inconsistencies in reported joint angles (r=0.79; RMSE=38.4°). Hand posture significantly influenced the quality of wrist deviation (P<0.005) and forearm supination/pronation (P<0.001), but not wrist flexion/extension (P=0.29). We conclude that the LMC is capable of providing data that are clinically meaningful for wrist flexion/extension, and perhaps wrist deviation. It cannot yet return clinically meaningful data for measuring forearm pronation/supination. Future studies should continue to validate the LMC as updated versions of their software are developed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Validation of the Hindi version of National Institute of Health Stroke Scale.

    Science.gov (United States)

    Prasad, Kameshwar; Dash, Deepa; Kumar, Amit

    2012-01-01

    To determine the reliability and validity of the National Institute of Health Stroke Scale (NIHSS) with the Hindi and Indian adaptation of items 9 and 10. NIHSS items 9 and 10 were modified and culturally adapted at All India Institute of Medical Sciences (AIIMS) and the resulting version was termed as Hindi version (HV-NIHSS). HV-NIHSS was applied by two independent investigators on 107 patients with stroke. Inter-observer agreement and intra-class correlation coefficients were calculated. The predictive validity of the HV-NIHSS was calculated using functional outcome after three months in the form of modified Rankin Scale (mRS) and Barthel Index (BI). The study included 107 patients of stroke recruited from a tertiary referral hospital at Delhi between November 1, 2009, and October 1, 2010; the mean age of these patients was 56.26±13.84 years and 65.4% of them had suffered ischemic stroke. Inter-rater reliability was high between the two examiners, with Pearson's r ranging from 0.72 to 0.99 for the 15 items on the Scale. Intra-class correlation coefficient for the total score was 0.995 (95% CI-0.993-0.997). Concurrent construct validity was established between HV-NIHSS and baseline Glasgow Coma Scale, with a high correlation (Spearman coefficient = -0.863, P<.001). Predictive validity was also established with BI at three months (Spearman's rho: -0.829, P<.001) and with mRS at three months (Spearman's rho: 0.851, P<0.001). This study shows that a Hindi language version of the NIHSS developed at AIIMS appears reliable and valid when applied to a Hindi-speaking population.

  9. Reliability and Validity of Selected PROMIS Measures in People with Rheumatoid Arthritis.

    Directory of Open Access Journals (Sweden)

    Susan J Bartlett

    Full Text Available To evaluate the reliability and validity of 11 PROMIS measures to assess symptoms and impacts identified as important by people with rheumatoid arthritis (RA.Consecutive patients (N = 177 in an observational study completed PROMIS computer adapted tests (CATs and a short form (SF assessing pain, fatigue, physical function, mood, sleep, and participation. We assessed test-test reliability and internal consistency using correlation and Cronbach's alpha. We assessed convergent validity by examining Pearson correlations between PROMIS measures and existing measures of similar domains and known groups validity by comparing scores across disease activity levels using ANOVA.Participants were mostly female (82% and white (83% with mean (SD age of 56 (13 years; 24% had ≤ high school, 29% had RA ≤ 5 years with 13% ≤ 2 years, and 22% were disabled. PROMIS Physical Function, Pain Interference and Fatigue instruments correlated moderately to strongly (rho's ≥ 0.68 with corresponding PROs. Test-retest reliability ranged from .725-.883, and Cronbach's alpha from .906-.991. A dose-response relationship with disease activity was evident in Physical Function with similar trends in other scales except Anger.These data provide preliminary evidence of reliability and construct validity of PROMIS CATs to assess RA symptoms and impacts, and feasibility of use in clinical care. PROMIS instruments captured the experiences of RA patients across the broad continuum of RA symptoms and function, especially at low disease activity levels. Future research is needed to evaluate performance in relevant subgroups, assess responsiveness and identify clinically meaningful changes.

  10. Correlation between increasing tissue ischemia and circulating levels of angiogenic growth factors in peripheral artery disease.

    Science.gov (United States)

    Jalkanen, Juho; Hautero, Olli; Maksimow, Mikael; Jalkanen, Sirpa; Hakovirta, Harri

    2018-04-21

    The aim of the present study was to assess the circulating levels of vascular endothelial growth factor (VEGF) and other suggested therapeutic growth factors with the degree of ischemia in patients with different clinical manifestations of peripheral arterial disease (PAD) according to the Rutherford grades. The study cohort consists of 226 consecutive patients admitted to a Department of Vascular Surgery for elective invasive procedures. PAD patients were grouped according to the Rutherford grades after a clinical assessment. Ankle-brachial pressure indices (ABI) and absolute toe pressure (TP) values were measured. Serum levels of circulating VEGF, hepatocyte growth factor (HGF), basic fibroblast growth factor (bFGF), and platelet derived growth factor (PDGF) were measured from serum and analysed against Rutherford grades and peripheral hemodynamic measurements. The levels of VEGF (P = 0.009) and HGF (P correlations between Rutherford grades was detected as follows; VEGF (Pearson's correlation = 0.183, P = 0.004), HGF (Pearson's correlation = 0.253, P Pearson's correlation = 0.169, P = 0.008) and PDGF (Pearson's correlation = 0.296, P correlation with ABI (Pearson's correlation -0.19, P = 0.009) and TP (Pearson's correlation -0.20, P = 0.005) measurements. Our present observations show that the circulating levels of VEGF and other suggested therapeutic growth factors are significantly increased along with increasing ischemia. These findings present a new perspective to anticipated positive effects of gene therapies utilizing VEGF, HGF, and bFGF, because the levels of these growth factors are endogenously high in end-stage PAD. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Reliability and Validity of a Novel Internet-Based Battery to Assess Mood and Cognitive Function in the Elderly.

    Science.gov (United States)

    Myers, Candice A; Keller, Jeffrey N; Allen, H Raymond; Brouillette, Robert M; Foil, Heather; Davis, Allison B; Greenway, Frank L; Johnson, William D; Martin, Corby K

    2016-10-18

    Dementia is a chronic condition in the elderly and depression is often a concurrent symptom. As populations continue to age, accessible and useful tools to screen for cognitive function and its associated symptoms in elderly populations are needed. The aim of this study was to test the reliability and validity of a new internet-based assessment battery for screening mood and cognitive function in an elderly population. Specifically, the Helping Hand Technology (HHT) assessments for depression (HHT-D) and global cognitive function (HHT-G) were evaluated in a sample of 57 elderly participants (22 male, 35 female) aged 59-85 years. The study sample was categorized into three groups: 1) dementia (n = 8; Mini-Mental State Exam (MMSE) score 10-24), 2) mild cognitive impairment (n = 24; MMSE score 25-28), and 3) control (n = 25; MMSE score 29-30). Test-retest reliability (Pearson correlation coefficient, r) and internal consistency reliability (Cronbach's alpha, α) of the HHT-D and HHT-G were assessed. Validity of the HHT-D and HHT-G was tested via comparison (Pearson r) to commonly used pencil-and-paper based assessments: HHT-D versus the Geriatric Depression Scale (GDS) and HHT-G versus the MMSE. Good test-retest (r = 0.80; p validity of the HHT-D was obtained (r = 0.60 between the HHT-D and GDS; p Validity of the HHT-G was supported (r = 0.71 between the HHT-G and MMSE; p valid computerized assessments to screen for depression and cognitive status, respectively, in an elderly sample.

  12. Cross-cultural adaptation and validation of als Functional Rating Scale-Revised in Portuguese language.

    Science.gov (United States)

    Guedes, Keyte; Pereira, Cecília; Pavan, Karina; Valério, Berenice Cataldo Oliveira

    2010-02-01

    The aim of this study is the cross-cultural, as well as to validate in Portuguese language the Amyotrophic Lateral Sclerosis Functional Rating Scale - Revised (ALSFRS-R). We performed a prospective study of individuals with amyotrophic lateral sclerosis (ALS) clinically defined. The scale, after obtaining the final version in Portuguese, was administered in 22 individuals and three weeks after re-applied. There were no significant differences between the application and reapplication of the scale (p=0.069). The linear regression and internal consistency measured by Pearson correlation and alpha Conbrach were significant with r=0.975 e alpha=0.934. The reliability test-retest demonstrated by intraclass correlation coefficient was strong with ICC=0.975. Therefore, this version proved to be applicable, reliable and easy to be conducted in clinical practice and research.

  13. Validation of the Brazilian version of the Burn Specific Health Scale-Brief (BSHS-B-Br).

    Science.gov (United States)

    Piccolo, Monica Sarto; Gragnani, Alfredo; Daher, Ricardo Piccolo; Scanavino, Marco de Tubino; de Brito, Maria José; Ferreira, Lydia Masako

    2015-11-01

    Progressive increases in survival rates from burn trauma have shifted attention to patient rehabilitation and posttraumatic quality of life. The assessment of quality of life is strongly dependent on reliable instruments for its measurement. A literature review has revealed that the Burn Specific Health Scale-Brief (BSHS-B) questionnaire is the most commonly used instrument worldwide. The aim of this study was to translate the BSHS-B into the Portuguese language, adapt it culturally to the Brazilian population, and test its psychometric properties. The questionnaire was translated into Portuguese; culturally adapted; and tested for reproducibility, face validity, content validity, and construct validity. The translated version was tested on 92 patients with burns. Internal consistency was tested by means of Cronbach's alpha. Construct validity was performed by correlating the BSHS-B questionnaire with the Burn Specific Health Scale-Revised (BSHS-R), BurnSexQ-Escola Paulista de Medicina (EPM)/Universidade Federal De São Paulo (UNIFESP), the Rosenberg Self-Esteem Scale (RSES), and the Beck Depression Inventory (BDI). Cronbach's alpha was 0.85. The Pearson correlation coefficients were significant at three time points of the reliability analysis. A significant correlation was observed between BSHS-B domains and BSHS-R, and between RSES and BDI domains. A significant correlation was also observed between BSHS-B and the BurnSexQ-EPM/UNIFESP social comfort and body image domains. The BSHS-B questionnaire was translated into Portuguese. It is a reliable tool in this language, showing face, content, and construct validity. The modified instrument has been named BSHS-B-Br. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  14. Reliability and Validity of Objective Structured Clinical Examination for Residents of Obstetrics and Gynecology at Kermanshah University of Medical Sciences

    Directory of Open Access Journals (Sweden)

    Nasrin Jalilian

    2012-11-01

    Full Text Available Introduction: Objective structured clinical examination (OSCE is used for the evaluation of the clinical competence in medicine for which it is essential to measure validity and reliability. This study aimed to investigate the validity and reliability of OSCE for residents of obstetrics and gynecology at Kermanshah University of Medical Sciences in 2011.Methods: A descriptive-correlation study was designed and the data of OSCE for obstetrics and gynecology were collected via learning behavior checklists in method stations and multiple choice questions in question stations. The data were analyzed through Pearson correlation coefficient and Cronbach's alpha, using SPSS software (version 16. To determine the criterion validity, correlation of OSCE scores with scores of resident promotion test, direct observation of procedural skills, and theoretical knowledge was determined; for reliability, however, Cronbach's alpha was used. Total sample consisted of 25 participants taking part in 14 stations. P value of less than 0.05 was considered as significant.Results: The mean OSCE scores was 22.66 (±6.85. Criterion validity of the stations with resident promotion theoretical test, first theoretical knowledge test, second theoretical knowledge, and direct observation of procedural skills (DOPS was 0.97, 0.74, 0.49, and 0.79, respectively. In question stations, criterion validity was 0.15, and total validity of OSCE was 0.77.Conclusion: Findings of the present study indicated acceptable validity and reliability of OSCE for residents of obstetrics and gynecology.

  15. Reliable and Valid Assessment of Clinical Bronchoscopy Performance

    DEFF Research Database (Denmark)

    Konge, Lars; Larsen, Klaus Richter; Clementsen, Paul

    2012-01-01

    : The interrater reliability was high, with Cronbach's a = 0.86. Assessment of 3 bronchoscopies by a single rater had a generalizability coefficient of 0.84. The correlation between experience and performance was good (Pearson correlation = 0.76). There were significant differences between the groups for all...

  16. Validation of the Italian translation of the Inflammatory Bowel Disease Questionnaire.

    Science.gov (United States)

    Ciccocioppo, Rachele; Klersy, Catherine; Russo, Maria Luisa; Valli, Monica; Boccaccio, Vincenzo; Imbesi, Venerina; Ardizzone, Sandro; Porro, Gabriele Bianchi; Corazza, Gino Roberto

    2011-07-01

    Health-related quality of life is an important measure of treatment outcome; its evaluation requires the use of internationally validated ad hoc questionnaires. The McMaster Inflammatory Bowel Disease Questionnaire (IBDQ) is the most used specific instrument. To assess the validity and reliability of the Italian translation of the IBDQ. The IBDQ underwent forward and backward translation; 13 patients were enrolled for cognitive testing of the Italian version to increase clarity. For field testing, 113 patients (65 with Crohn's disease and 48 with ulcerative colitis) completed both the IBDQ and the generic instrument 36-item Short Form Health Survey scale (SF-36). Data quality was optimal with high completeness and low floor and ceiling effect. Item internal consistency was satisfied for 100% of patients, while discriminant validity showed a few items with higher correlations with other scales. Cronbach's alpha coefficient was 0.96. Test-retest correlations indicated good reliability (Pearson R 0.81). Exploratory factor analysis indicated that the original grouping of the item was suboptimal. The score proved sensitive to disease activity, gender and quality of life as measured by the SF-36. The Italian translation of the McMaster Inflammatory Bowel Disease Questionnaire sounds natural and is easy to understand. A field test gave results comparable to other international validations, supporting its use in cross-national surveys. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Lesion size detection in geographic atrophy by polarization-sensitive optical coherence tomography and correlation to conventional imaging techniques.

    Science.gov (United States)

    Schütze, Christopher; Bolz, Matthias; Sayegh, Ramzi; Baumann, Bernhard; Pircher, Michael; Götzinger, Erich; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2013-01-28

    To investigate the reproducibility of automated lesion size detection in patients with geographic atrophy (GA) using polarization-sensitive spectral-domain optical coherence tomography (PS-OCT) and to compare findings with scanning laser ophthalmoscopy (SLO), fundus autofluorescence (FAF), and intensity-based spectral-domain OCT (SD-OCT). Twenty-nine eyes of 22 patients with GA were examined by PS-OCT, selectively identifying the retinal pigment epithelium (RPE). A novel segmentation algorithm was applied, automatically detecting and quantifying areas of RPE atrophy. The reproducibility of the algorithm was assessed, and lesion sizes were correlated with manually delineated SLO, FAF, and intensity-based SD-OCT images to validate the clinical applicability of PS-OCT in GA evaluation. Mean GA lesion size of all patients was 5.28 mm(2) (SD: 4.92) in PS-OCT. Mean variability of individual repeatability measurements was 0.83 mm(2) (minimum: 0.05; maximum: 3.65). Mean coefficient of variation was 0.07 (min: 0.01; max: 0.19). Mean GA area in SLO (Spectralis OCT) was 5.15 mm(2) (SD: 4.72) and 2.5% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area in intensity-based SD-OCT pseudo-SLO images (Cirrus OCT) was 5.14 mm(2) (SD: 4.67) and 2.7% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area of all eyes measured 5.41 mm(2) (SD: 4.75) in FAF, deviating by 2.4% from PS-OCT results (P = 0.89, Pearson correlation coefficient = 0.99, P < 0.01). PS-OCT demonstrated high reproducibility of GA lesion size determination. Results correlated well with SLO, FAF, and intensity-based SD-OCT fundus imaging. PS-OCT may therefore be a valuable and specific imaging modality for automated GA lesion size determination in scientific studies and clinical practice.

  18. Relative validity of a semi-quantitative, web-based FFQ used in the ‘Snart Forældre’ cohort – a Danish study of diet and fertility

    DEFF Research Database (Denmark)

    Knudsen, Vibeke Kildegaard; Hatch, Elizabeth E.; Cueto, Heidi

    2015-01-01

    the relative validity of intakes of foods and nutrients. We compared means and medians of intakes, and calculated Pearson correlation coefficients and de-attenuated coefficients to assess agreement between the two methods. We also calculated the proportion correctly classified based on the same or adjacent......-seven women aged 20–42 years. Results: Reported intakes of dairy products, vegetables and potatoes were higher in the FFQ compared with the FD, whereas reported intakes of fruit, meat, sugar and beverages were lower in the FFQ than in the FD. Overall the de-attenuated correlation coefficients were acceptable...

  19. German validation of the Conners Adult ADHD Rating Scales (CAARS) II: reliability, validity, diagnostic sensitivity and specificity.

    Science.gov (United States)

    Christiansen, H; Kis, B; Hirsch, O; Matthies, S; Hebebrand, J; Uekermann, J; Abdel-Hamid, M; Kraemer, M; Wiltfang, J; Graf, E; Colla, M; Sobanski, E; Alm, B; Rösler, M; Jacob, C; Jans, T; Huss, M; Schimmelmann, B G; Philipsen, A

    2012-07-01

    The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires. CAARS-S/O and questions on sociodemographic variables were filled out by 466 patients with ADHD, 847 healthy control subjects that already participated in two prior studies, and a total of 896 observer data sets were available. Cronbach's-alpha was calculated to obtain internal reliability coefficients. Pearson correlations were performed to assess test-retest reliability, and concurrent, criterion, and discriminant validity. Receiver Operating Characteristics (ROC-analyses) were used to establish sensitivity and specificity for all subscales. Coefficient alphas ranged from .74 to .95, and test-retest reliability from .85 to .92 for the CAARS-S, and from .65 to .85 for the CAARS-O. All CAARS subscales, except problems with self-concept correlated significantly with the Barrett Impulsiveness Scale (BIS), but not with the Wender Utah Rating Scale (WURS). Criterion validity was established with ADHD subtype and diagnosis based on DSM-IV criteria. Sensitivity and specificity were high for all four subscales. The reported results confirm our previous study and show that the German CAARS-S/O do indeed represent a reliable and cross-culturally valid measure of current ADHD symptoms in adults. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  20. The Heart of Great Teaching: Pearson Global Survey of Educator Effectiveness

    Science.gov (United States)

    McKnight, Katherine; Graybeal, John; Yarbro, Jessica; Graybeal, Lacey

    2016-01-01

    To contribute to the global discussion about what makes an effective teacher, Pearson surveyed students ages 15-19, teachers, principals, education researchers, education policymakers, and parents of school-aged children in 23 countries (Canada, U.S., Mexico, Brazil, Argentina, Finland, Germany, Poland, England, Morocco, Egypt, South Africa,…

  1. Criterion-Related Validity of a Simple Muscle Strength Test to Assess Whole Body Muscle Strength in Chinese Children Aged 10 to 12 Years.

    Science.gov (United States)

    Yin, Liqin; Tang, Changfa; Tao, Xia

    2018-01-01

    To study the criterion-related validity of simple muscle strength test (SMST) indicators and assess whole body muscle strength in Chinese children aged 10 to 12 years old. Two hundred and forty children were equally divided into four groups in different genders and residences. The SMST indicators (hand-grip, knee bent push-up, back muscle strength, sit-up, leg muscle strength, and standing long jump) were tested. We set up the total level of the whole-body muscle strength ( F total ) through testing isokinetic muscle strength of the six joints' flexion and extension movements. Pearson correlation analyses were used to analyze the correlation between the SMST indicators and the F total . (1) Leg muscle strength and back muscle strength demonstrated the highest validity scores. Sit-ups, hand grip, and standing long jump demonstrated the lowest validity scores. (2) Leg muscle strength had the highest validity for males, but back muscle strength had the highest validity for females. Back muscle strength and leg muscle strength can give the highest validity of assessing whole body muscle strength, and also has higher validity in both the urban and rural children. For urban children, but not rural, the knee bent push-up also has a high validity indicator.

  2. Criterion-Related Validity of a Simple Muscle Strength Test to Assess Whole Body Muscle Strength in Chinese Children Aged 10 to 12 Years

    Directory of Open Access Journals (Sweden)

    Liqin Yin

    2018-01-01

    Full Text Available Objective. To study the criterion-related validity of simple muscle strength test (SMST indicators and assess whole body muscle strength in Chinese children aged 10 to 12 years old. Methods. Two hundred and forty children were equally divided into four groups in different genders and residences. The SMST indicators (hand-grip, knee bent push-up, back muscle strength, sit-up, leg muscle strength, and standing long jump were tested. We set up the total level of the whole-body muscle strength (Ftotal through testing isokinetic muscle strength of the six joints’ flexion and extension movements. Pearson correlation analyses were used to analyze the correlation between the SMST indicators and the Ftotal. Results. (1 Leg muscle strength and back muscle strength demonstrated the highest validity scores. Sit-ups, hand grip, and standing long jump demonstrated the lowest validity scores. (2 Leg muscle strength had the highest validity for males, but back muscle strength had the highest validity for females. Conclusions. Back muscle strength and leg muscle strength can give the highest validity of assessing whole body muscle strength, and also has higher validity in both the urban and rural children. For urban children, but not rural, the knee bent push-up also has a high validity indicator.

  3. Upper bounds for Neyman-Pearson cooperative spectrum sensing

    KAUST Repository

    Zahabi, Sayed Jalal; Tadaion, Ali Akbar; Aissa, Sonia

    2011-01-01

    We consider a cooperative spectrum sensing scenario where the local sensors at the secondary users are viewed as one-level quantizers, and the quantized data are to be fused under Neyman-Pearson (N-P) criterion. We demonstrate how the N-P fusion results in a randomized test, which represents the total performance of our spectrum sensing scheme. We further introduce an upper performance bound for the overall primary user signal detection. An analytical procedure towards the upper bound and its relevant quantization setup at the local sensors are proposed and examined through simulations. © 2011 IEEE.

  4. Upper bounds for Neyman-Pearson cooperative spectrum sensing

    KAUST Repository

    Zahabi, Sayed Jalal

    2011-06-01

    We consider a cooperative spectrum sensing scenario where the local sensors at the secondary users are viewed as one-level quantizers, and the quantized data are to be fused under Neyman-Pearson (N-P) criterion. We demonstrate how the N-P fusion results in a randomized test, which represents the total performance of our spectrum sensing scheme. We further introduce an upper performance bound for the overall primary user signal detection. An analytical procedure towards the upper bound and its relevant quantization setup at the local sensors are proposed and examined through simulations. © 2011 IEEE.

  5. Cross-Cultural adaption, validity and reliability of a Hindi version of the Corah's Dental Anxiety Scale.

    Science.gov (United States)

    Jain, Meena; Tandon, Shourya; Sharma, Ankur; Jain, Vishal; Rani Yadav, Nisha

    2018-01-01

    Background: An appropriate scale to assess the dental anxiety of Hindi speaking population is lacking. This study, therefore, aims to evaluate the psychometric properties of Hindi version of one of the oldest dental anxiety scale, Corah's Dental Anxiety Scale (CDAS) in Hindi speaking Indian adults. Methods: A total of 348 subjects from the outpatient department of a dental hospital in India participated in this cross-sectional study. The scale was cross-culturally adapted by forward and backward translation, committee review and pretesting method. The construct validity of the translated scale was explored with exploratory factor analysis. The correlation of the Hindi version of CDAS with visual analogue scale (VAS) was used to measure the convergent validity. Reliability was assessed through calculations of Cronbach's alpha and intra class correlation 48 forms were completed for test-retest. Results: Prevalence of dental anxiety in the sample within the age range of 18-80 years was 85.63% [95% CI: 0.815-0.891]. The response rate was 100 %. Kaiser-Meyer-Olkin (KMO) test value was 0.776. After factor analysis, a single factor (dental anxiety) was obtained with 4 items.The single factor model explained 61% variance. Pearson correlation coefficient between CDASand VAS was 0.494. Test-retest showed the Cronbach's alpha value of 0.814. The test-retest intraclass correlation coefficient of the total CDAS score was 0.881 [95% CI: 0.318-0.554]. Conclusion: Hindi version of CDAS is a valid and reliable scale to assess dental anxiety in Hindi speaking population. Convergent validity is well recognized but discriminant validity is limited and requires further study.

  6. Reliability and validity of the 12-item WHODAS 2.0 in patients with Kashin-Beck disease.

    Science.gov (United States)

    Younus, Mohammad Imran; Wang, Di-Miao; Yu, Fang-Fang; Fang, Hua; Guo, Xiong

    2017-09-01

    The purpose of this study was to check the reliability and validity of the 12-item Chinese version of the World Health Organization Disability Assessment Schedule 2.0 (WHODAS 2.0) for the assessment of disability in patients with Kashin-Beck disease (KBD). We recruited 219 patients with KBD from the high-risk KBD area in the Shaanxi province, using stratified multistage random sampling. We assessed each patient using the Chinese version of the 12-item WHODAS 2.0 and the Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC). Statistical evaluations of the instruments consisted of Cronbach's alpha, intraclass correlation coefficient (ICC), confirmatory factor analysis (CFA), and Pearson's correlation coefficient. Cronbach's alpha and ICC for the six domains ranged from 0.704 to 0.906 and 0.690 to 0.852, respectively. A six-factor structure fits the data well (CFI = 0.967, TLI = 0.944, RMSEA = 0.08). Regarding convergent validity, the four domains of the 12-item WHODAS 2.0 (getting around, self-care, life activity, and participation) showed moderate-to-strong correlation for all three domains of the WOMAC (0.428 < |r| < 0.804). Regarding divergent validity, the two domains of the 12-item WHODAS 2.0 (understanding and communication, and getting along with people) showed weak correlation for the three domains of WOMAC (0.182 < |r| < 0.295). The Chinese version of 12-item WHODAS 2.0 questionnaire is a reliable and valid instrument when administered to KBD patients.

  7. Validation of Indonesian Version of FACIT Fatigue Scale Questionnaire in Chronic Kidney Disease (CKD Patients with Routine Hemodialysis

    Directory of Open Access Journals (Sweden)

    Jhonson P. Sihombing

    2016-12-01

    Full Text Available Anemia is common in Chronic Kidney Disease (CKD. One of anemia consequences is fatigue which can lead to decrease in quality of life. Functional Assessment Chronic Illness Therapy (FACIT Fatigue Scale is an instrument to measure patient’s score of fatigue. This questionnaire is not validated yet in Indonesia. The aim of this study is to validate Indonesian version of Functional Assessment Chronic Illness Therapy (FACIT Fatigue Scale as an instrument for patient’s quality of life. FACIT Fatigue Scale was translated into Indonesian and administrated to CKD patients with routine homodialysis in an academic hospital in Yogyakarta on May until October 2015. The validity was evaluated by Pearson correlation test and the reliability was evaluated by Cronbach’s alpha test. Validity test showed that all of the questions were valid because r count was bigger than r table=0,279 and reliable because r11=0,646>0,6. In conclusion, Indonesian version of FACIT Fatigue Scale was a brief and valid to monitor important symptom and its effect on CKD patients with routine hemodialysis.

  8. Sexual Harassment Retaliation Climate DEOCS 4.1 Construct Validity Summary

    Science.gov (United States)

    2017-08-01

    Correlations Bivariate Pearson correlation among items were examined to identify and reduce questions with overlapping content. Table 5 displays the...exploratory factor analysis, and bivariate correlations (sample 1) 2) To determine the factor structure of the remaining (final) questions via...statistics, reliability analysis, exploratory factor analysis, and bivariate correlations of the prospective Sexual Harassment Retaliation Climate

  9. Adaptation and validation of the German Patient Activation Measure for adolescents with chronic conditions in transitional care: PAM® 13 for Adolescents.

    Science.gov (United States)

    Bomba, Franziska; Markwart, Henriette; Mühlan, Holger; Menrath, Ingo; Ernst, Gundula; Thyen, Ute; Schmidt, Silke

    2018-02-01

    Measuring adolescent patients' engagement in their health care is especially important in preparing for chronically ill adolescents' transition into adult care. In this study, we aimed to create an adolescent version of the German language Patient Activation Measure (PAM-13-D) originally tested in in adults and psychometrically test the adapted measure (PAM ® 13 for Adolescents). After linguistic and content-related adaptations, the PAM ® 13 for Adolescents was tested in a large sample of adolescents with different chronic conditions (N = 586, mean age 17.5 years, SD = 1.4) in 40 health centers. Internal consistency was assessed with Cronbach's alpha and test-retest reliability with Pearson correlation. Convergent and divergent validity were calculated with Pearson correlations between the two IE-4 scales (internal and external Locus of Control) and the PAM ® 13 for Adolescents. Known-group validity (type 1 diabetes vs. IBD, higher vs. lower education level) was checked by Mann-Whitney-U-tests. The PAM ® 13 for Adolescents showed good test-retest reliability (rtt = .68), internal consistency (α = .79) and demonstrated good validity. The original structure of the PAM 13-D was replicated. Rasch analysis using the partial credit model was used to investigate the operating characteristics of the items. Rasch analysis indicated a sufficient fit of 12 of the 13 items. PAM ® 13 for Adolescents is the first instrument measuring patient activation of adolescents with chronic conditions in a broad age range. Patient activation level can be used by clinicians to better plan and structure transition processes. © 2017 Wiley Periodicals, Inc.

  10. Validation of self assessment patient knowledge questionnaire for heart failure patients.

    Science.gov (United States)

    Lainscak, Mitja; Keber, Irena

    2005-12-01

    Several studies showed insufficient knowledge and poor compliance to non-pharmacological management in heart failure patients. Only a limited number of validated tools are available to assess their knowledge. The aim of the study was to test our 10-item Patient knowledge questionnaire. The Patient knowledge questionnaire was administered to 42 heart failure patients from Heart failure clinic and to 40 heart failure patients receiving usual care. Construct validity (Pearson correlation coefficient), internal consistency (Cronbach alpha), reproducibility (Wilcoxon signed rank test), and reliability (chi-square test and Student's t-test for independent samples) were assessed. Overall score of the Patient knowledge questionnaire had the strongest correlation to the question about regular weighing (r=0.69) and the weakest to the question about presence of heart disease (r=0.33). There was a strong correlation between question about fluid retention and questions assessing regular weighing, (r=0.86), weight of one litre of water (r=0.86), and salt restriction (r=0.57). The Cronbach alpha was 0.74 and could be improved by exclusion of questions about clear explanation (Chronbach alpha 0.75), importance of fruit, soup, and vegetables (Chronbach alpha 0.75), and self adjustment of diuretic (Chronbach alpha 0.81). During reproducibility testing 91% to 98% of questions were answered equally. Patients from Heart failure clinic scored significantly better than patients receiving usual care (7.9 (1.3) vs. 5.7 (2.2), p<0.001). Patient knowledge questionnaire is a valid and reliable tool to measure knowledge of heart failure patients.

  11. Spanish validation of Bad Sobernheim Stress Questionnaire (BSSQ (brace.es for adolescents with braces

    Directory of Open Access Journals (Sweden)

    Rigo Manuel

    2010-07-01

    Full Text Available Abstract Background As a result of scientific and medical professionals gaining interest in Stress and Health Related Quality of Life (HRQL, the aim of our research is, thus, to validate into Spanish the German questionnaire Bad Sobernheim Stress Questionnaire (BSSQ (mit Korsett, for adolescents wearing braces. Methods The methodology used adheres to literature on trans-cultural adaptation by doing a translation and a back translation; it involved 35 adolescents, ages ranging between 10 and 16, with Adolescent Idiopathic Scoliosis (AIS and wearing the same kind of brace (Rigo System Chêneau Brace. The materials used were a socio-demographics data questionnaire, the SRS-22 and the Spanish version of BSSQ(brace.es. The statistical analysis calculated the reliability (test-retest reliability and internal consistency and the validity (convergent and construct validity of the BSSQ (brace.es. Results BSSQ(brace.es is reliable because of its satisfactory internal consistency (Cronbach's alpha coefficient was 0.809, p It demonstrated convergent validity with SRS-22 since the Pearson correlation coefficient was 0.656 (p Conclusions BSSQ (brace.es is reliable and valid and can be used with Spanish adolescents to assess the stress level caused by the brace.

  12. Reliability and validity of an adapted Arabic version of the Scoliosis Research Society-22r Questionnaire.

    Science.gov (United States)

    Haidar, Rachid K; Kassak, Kassem; Masrouha, Karim; Ibrahim, Kamal; Mhaidli, Hani

    2015-09-01

    Cross-sectional validation and reliability assessment study of Arabic version of Scoliosis Research Society-22 (SRS-22r) Questionnaire. To develop and validate the Arabic version of the SRS-22r questionnaire. The diagnosis and treatment of adolescent idiopathic scoliosis may influence patient quality of life. SRS-22r is an internationally validated questionnaire used to assess function/activity, pain, self-image, and mental health of patients with scoliosis. It has been translated into several languages but not into Arabic language. Therefore, a valid health-related quality-of-life outcome questionnaire for patients with spinal deformity is still lacking in Arabic language. The English version of SRS-22r questionnaire was translated, back-translated, and culturally adapted to Arabic language. Then, 81 patients with idiopathic adolescent scoliosis were allocated randomly into either the reliability testing group (group 1) or the validity testing group (group 2). Group 1 patients completed Arabic version of SRS-22r questionnaire twice with 1-week interval in-between. Cronbach α and intraclass correlation coefficient were measured to determine internal consistency and temporal reliability. Group 2 patients completed the Arabic version of SRS-22r questionnaire and the previously validated Arabic version of 36-Item Short Form Health Survey (Short Form-36) questionnaire concurrently, and Pearson correlation coefficient was obtained to assess validity. Content analysis, internal consistency reliability, test/retest reproducibility (intraclass correlation coefficient range: 0.82-0.90), and test of concurrent validity showed satisfactory results. Function/activity and satisfaction with management domains had a lower Cronbach α (0.58 and 0.44, respectively, vs. 0.71-0.85 range for others). Self-image/appearance and satisfaction with management had a lower correlation with domains of the 36-Item Short Form Health Survey. An Arabic version of the SRS-22r questionnaire has

  13. Prospective Study Validating Inter- and Intraobserver Variability of Tissue Compliance Meter in Breast Tissue of Healthy Volunteers: Potential Implications for Patients With Radiation-Induced Fibrosis of the Breast

    International Nuclear Information System (INIS)

    Wernicke, A. Gabriella; Parashar, Bhupesh; Kulidzhanov, Fridon; Riley, Lillian; Christos, Paul J.; Fischer, Andrew; Nori, Dattatreyudu; Chao, K.S. Clifford

    2011-01-01

    Purpose: Accurate detection of radiation-induced fibrosis (RIF) is crucial in management of breast cancer survivors. Tissue compliance meter (TCM) has been validated in musculature. We validate TCM in healthy breast tissue with respect to interobserver and intraobserver variability before applying it in RIF. Methods and Materials: Three medical professionals obtained three consecutive TCM measurements in each of the four quadrants of the right and left breasts of 40 women with no breast disease or surgical intervention. The intraclass correlation coefficient (ICC) assessed interobserver variability. The paired t test and Pearson correlation coefficient (r) were used to assess intraobserver variability within each rater. Results: The median age was 45 years (range, 24-68 years). The median bra size was 35C (range, 32A-40DD). Of the participants, 27 were white (67%), 4 black (10%), 5 Asian (13%), and 4 Hispanic (10%). ICCs indicated excellent interrater reliability (low interobserver variability) among the three raters, by breast and quadrant (all ICC ≥0.99). The paired t test and Pearson correlation coefficient both indicated low intraobserver variability within each rater (right vs. left breast), stratified by quadrant (all r≥ 0.94, p < 0.0001). Conclusions: The interobserver and intraobserver variability is small using TCM in healthy mammary tissue. We are now embarking on a prospective study using TCM in women with breast cancer at risk of developing RIF that may guide early detection, timely therapeutic intervention, and assessment of success of therapy for RIF.

  14. APLIKASI KORELASI PEARSON DALAM MEMBANGUN MODEL TREE-AUGMENTED NETWORK (TAN (Studi Kasus Pengenalan Karakter Tulisan Tangan

    Directory of Open Access Journals (Sweden)

    Irwan Budi Santoso

    2013-10-01

    Full Text Available Langkah pertama dalam membangun model pengenalan Tree-Augmented Network (TAN  dengan  mengukur  besarnya  hubungan  diantara  pasangan  fitur  objek.  Salah  satu metode yang dapat digunakan mengukur besarnya keeratan hubungan secara linier diantara pasangan fitur adalah   Korelasi Pearson. Aplikasi Korelasi Pearson  dalam membangun model Tree-Augmented Network (TAN dalam penelitian ini, akan diujicobakan pada kasus membangun  model pengenalan karakter tulisan tangan. Data fitur karakter tulisan tangan untuk kasus ini, diasumsikan mengikuti distribusi gaussian karena estimasi parameter model pengenalannya menggunakan estimator Maximum Likelihood (ML. Hasil eksperimen dengan menggunakan data training yang terdiri dari 5 jenis karakter tulisan tangan, menunjukkan untuk dimensi fitur karakter tulisan tangan 10x30 (30 fitur, akurasi sistem Korelasi Pearson dalam membangun model TAN untuk mengenali karakter tulisan tangan  sebesar 88 %.

  15. [Reliability and validity of the Chinese version on Comprehensive Scores for Financial Toxicity based on the patient-reported outcome measures].

    Science.gov (United States)

    Yu, H H; Bi, X; Liu, Y Y

    2017-08-10

    Objective: To evaluate the reliability and validity of the Chinese version on comprehensive scores for financial toxicity (COST), based on the patient-reported outcome measures. Methods: A total of 118 cancer patients were face-to-face interviewed by well-trained investigators. Cronbach's α and Pearson correlation coefficient were used to evaluate reliability. Content validity index (CVI) and exploratory factor analysis (EFA) were used to evaluate the content validity and construct validity, respectively. Results: The Cronbach's α coefficient appeared as 0.889 for the whole questionnaire, with the results of test-retest were between 0.77 and 0.98. Scale-content validity index (S-CVI) appeared as 0.82, with item-content validity index (I-CVI) between 0.83 and 1.00. Two components were extracted from the Exploratory factor analysis, with cumulative rate as 68.04% and loading>0.60 on every item. Conclusion: The Chinese version of COST scale showed high reliability and good validity, thus can be applied to assess the financial situation in cancer patients.

  16. Cross-Cultural adaption, validity and reliability of a Hindi version of the Corah’s Dental Anxiety Scale

    Directory of Open Access Journals (Sweden)

    Meena Jain

    2018-04-01

    Full Text Available Background: An appropriate scale to assess the dental anxiety of Hindi speaking population is lacking. This study, therefore, aims to evaluate the psychometric properties of Hindi version of one of the oldest dental anxiety scale, Corah’s Dental Anxiety Scale (CDAS in Hindi speaking Indian adults.Methods: A total of 348 subjects from the outpatient department of a dental hospital in Indiaparticipated in this cross-sectional study. The scale was cross-culturally adapted by forward and backward translation, committee review and pretesting method. The construct validity of the translated scale was explored with exploratory factor analysis. The correlation of the Hindi version of CDAS with visual analogue scale (VAS was used to measure the convergent validity.Reliability was assessed through calculations of Cronbach’s alpha and intra class correlation 48 forms were completed for test-retest.Results: Prevalence of dental anxiety in the sample within the age range of 18-80 years was 85.63% [95% CI: 0.815-0.891]. The response rate was 100 %. Kaiser-Meyer-Olkin (KMO test value was 0.776. After factor analysis, a single factor (dental anxiety was obtained with 4 items.The single factor model explained 61% variance. Pearson correlation coefficient between CDASand VAS was 0.494. Test-retest showed the Cronbach’s alpha value of 0.814. The test-retest intraclass correlation coefficient of the total CDAS score was 0.881 [95% CI: 0.318-0.554].Conclusion: Hindi version of CDAS is a valid and reliable scale to assess dental anxiety in Hindi speaking population. Convergent validity is well recognized but discriminant validity is limited and requires further study.

  17. Cross-Cultural adaption, validity and reliability of a Hindi version of the Corah’s Dental Anxiety Scale

    Science.gov (United States)

    Jain, Meena; Tandon, Shourya; Sharma, Ankur; Jain, Vishal; Rani Yadav, Nisha

    2018-01-01

    Background: An appropriate scale to assess the dental anxiety of Hindi speaking population is lacking. This study, therefore, aims to evaluate the psychometric properties of Hindi version of one of the oldest dental anxiety scale, Corah’s Dental Anxiety Scale (CDAS) in Hindi speaking Indian adults. Methods: A total of 348 subjects from the outpatient department of a dental hospital in India participated in this cross-sectional study. The scale was cross-culturally adapted by forward and backward translation, committee review and pretesting method. The construct validity of the translated scale was explored with exploratory factor analysis. The correlation of the Hindi version of CDAS with visual analogue scale (VAS) was used to measure the convergent validity. Reliability was assessed through calculations of Cronbach’s alpha and intra class correlation 48 forms were completed for test-retest. Results: Prevalence of dental anxiety in the sample within the age range of 18-80 years was 85.63% [95% CI: 0.815-0.891]. The response rate was 100 %. Kaiser-Meyer-Olkin (KMO) test value was 0.776. After factor analysis, a single factor (dental anxiety) was obtained with 4 items.The single factor model explained 61% variance. Pearson correlation coefficient between CDASand VAS was 0.494. Test-retest showed the Cronbach’s alpha value of 0.814. The test-retest intraclass correlation coefficient of the total CDAS score was 0.881 [95% CI: 0.318-0.554]. Conclusion: Hindi version of CDAS is a valid and reliable scale to assess dental anxiety in Hindi speaking population. Convergent validity is well recognized but discriminant validity is limited and requires further study. PMID:29744307

  18. Validity of a jump training apparatus using Wii Balance Board.

    Science.gov (United States)

    Yamamoto, Keizo; Matsuzawa, Mamoru

    2013-05-01

    The dynamic quantification of jump ability is useful for sports performance evaluation. We developed a force measurement system using the Wii Balance Board (WBB). This study was conducted to validate the system in comparison with a laboratory-grade force plate (FP). For a static validation, weights of 10-180kg were put progressively on the WBB put on the FP. The vertical component of the ground reaction force (vGRF) was measured using both devices and compared. For the dynamic validation, 10 subjects without lower limb pathology participated in the study and performed vertical jumping twice on the WBB on the FP. The range of analysis was set from the landing after the first jump to taking off of the second jump. The peak values during the landing phase and jumping phase were obtained and the force-time integral (force impulse) was measured. The relations of the values measured using each device were compared using Pearson's correlation coefficient test and Bland-Altman plots (BAP). Significant correlation (P<.01, r=.99) was found between the values of both devices in the static and the dynamic test. Examination of the BAP revealed a proportion error in the landing phase and showed no relation in the jumping phase between the difference and the mean in the dynamic test. The WBB detects the vGRF in the jumping phase with high precision. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Genome-scale cluster analysis of replicated microarrays using shrinkage correlation coefficient.

    Science.gov (United States)

    Yao, Jianchao; Chang, Chunqi; Salmi, Mari L; Hung, Yeung Sam; Loraine, Ann; Roux, Stanley J

    2008-06-18

    Currently, clustering with some form of correlation coefficient as the gene similarity metric has become a popular method for profiling genomic data. The Pearson correlation coefficient and the standard deviation (SD)-weighted correlation coefficient are the two most widely-used correlations as the similarity metrics in clustering microarray data. However, these two correlations are not optimal for analyzing replicated microarray data generated by most laboratories. An effective correlation coefficient is needed to provide statistically sufficient analysis of replicated microarray data. In this study, we describe a novel correlation coefficient, shrinkage correlation coefficient (SCC), that fully exploits the similarity between the replicated microarray experimental samples. The methodology considers both the number of replicates and the variance within each experimental group in clustering expression data, and provides a robust statistical estimation of the error of replicated microarray data. The value of SCC is revealed by its comparison with two other correlation coefficients that are currently the most widely-used (Pearson correlation coefficient and SD-weighted correlation coefficient) using statistical measures on both synthetic expression data as well as real gene expression data from Saccharomyces cerevisiae. Two leading clustering methods, hierarchical and k-means clustering were applied for the comparison. The comparison indicated that using SCC achieves better clustering performance. Applying SCC-based hierarchical clustering to the replicated microarray data obtained from germinating spores of the fern Ceratopteris richardii, we discovered two clusters of genes with shared expression patterns during spore germination. Functional analysis suggested that some of the genetic mechanisms that control germination in such diverse plant lineages as mosses and angiosperms are also conserved among ferns. This study shows that SCC is an alternative to the Pearson

  20. Correlation of diffusion and perfusion MRI with Ki-67 in high-grade meningiomas.

    Science.gov (United States)

    Ginat, Daniel T; Mangla, Rajiv; Yeaney, Gabrielle; Wang, Henry Z

    2010-12-01

    Atypical and anaplastic meningiomas have a greater likelihood of recurrence than benign meningiomas. The risk for recurrence is often estimated using the Ki-67 labeling index. The purpose of this study was to determine the correlation between Ki-67 and regional cerebral blood volume (rCBV) and between Ki-67 and apparent diffusion coefficient (ADC) in atypical and anaplastic meningiomas. A retrospective review of the advanced imaging and immunohistochemical characteristics of atypical and anaplastic meningiomas was performed. The relative minimum ADC, relative maximum rCBV, and specimen Ki-67 index were measured. Pearson's correlation was used to compare these parameters. There were 23 cases with available ADC maps and 20 cases with available rCBV maps. The average Ki-67 among the cases with ADC maps and rCBV maps was 17.6% (range, 5-38%) and 16.7% (range, 3-38%), respectively. The mean minimum ADC ratio was 0.91 (SD, 0.26) and the mean maximum rCBV ratio was 22.5 (SD, 7.9). There was a significant positive correlation between maximum rCBV and Ki-67 (Pearson's correlation, 0.69; p = 0.00038). However, there was no significant correlation between minimum ADC and Ki-67 (Pearson's correlation, -0.051; p = 0.70). Maximum rCBV correlated significantly with Ki-67 in high-grade meningiomas.

  1. Evidence for validity and reliability of a french version of the FAAM

    Directory of Open Access Journals (Sweden)

    Ballabeni Pierluigi

    2011-02-01

    Full Text Available Abstract Background The Foot and Ankle Ability Measure (FAAM is a self reported questionnaire for patients with foot and ankle disorders available in English, German, and Persian. This study plans to translate the FAAM from English to French (FAAM-F and assess the validity and reliability of this new version. Methods The FAAM-F Activities of Daily Living (ADL and sports subscales were completed by 105 French-speaking patients (average age 50.5 years presenting various chronic foot and ankle disorders. Convergent and divergent validity was assessed by Pearson's correlation coefficients between the FAAM-F subscales and the SF-36 scales: Physical Functioning (PF, Physical Component Summary (PCS, Mental Health (MH and Mental Component Summary (MCS. Internal consistency was calculated by Cronbach's Alpha (CA. To assess test re-test reliability, 22 patients filled out the questionnaire a second time to estimate minimal detectable changes (MDC and intraclass correlation coefficients (ICC. Results Correlations for FAAM-F ADL subscale were 0.85 with PF, 0.81 with PCS, 0.26 with MH, 0.37 with MCS. Correlations for FAAM-F Sports subscale were 0.72 with PF, 0.72 with PCS, 0.21 with MH, 0.29 with MCS. CA estimates were 0.97 for both subscales. Respectively for the ADL and Sports subscales, ICC were 0.97 and 0.94, errors for a single measure were 8 and 10 points at 95% confidence and the MDC values at 95% confidence were 7 and 18 points. Conclusion The FAAM-F is valid and reliable for the self-assessment of physical function in French-speaking patients with a wide range of chronic foot and ankle disorders.

  2. The Myotonometer: Not a Valid Measurement Tool for Active Hamstring Musculotendinous Stiffness.

    Science.gov (United States)

    Pamukoff, Derek N; Bell, Sarah E; Ryan, Eric D; Blackburn, J Troy

    2016-05-01

    Hamstring musculotendinous stiffness (MTS) is associated with lower-extremity injury risk (ie, hamstring strain, anterior cruciate ligament injury) and is commonly assessed using the damped oscillatory technique. However, despite a preponderance of studies that measure MTS reliably in laboratory settings, there are no valid clinical measurement tools. A valid clinical measurement technique is needed to assess MTS and permit identification of individuals at heightened risk of injury and track rehabilitation progress. To determine the validity and reliability of the Myotonometer for measuring active hamstring MTS. Descriptive laboratory study. Laboratory. 33 healthy participants (15 men, age 21.33 ± 2.94 y, height 172.03 ± 16.36 cm, mass 74.21 ± 16.36 kg). Hamstring MTS was assessed using the damped oscillatory technique and the Myotonometer. Intraclass correlations were used to determine the intrasession, intersession, and interrater reliability of the Myotonometer. Criterion validity was assessed via Pearson product-moment correlation between MTS measures obtained from the Myotonometer and from the damped oscillatory technique. The Myotonometer demonstrated good intrasession (ICC3,1 = .807) and interrater reliability (ICC2,k = .830) and moderate intersession reliability (ICC2,k = .693). However, it did not provide a valid measurement of MTS compared with the damped oscillatory technique (r = .346, P = .061). The Myotonometer does not provide a valid measure of active hamstring MTS. Although the Myotonometer does not measure active MTS, it possesses good reliability and portability and could be used clinically to measure tissue compliance, muscle tone, or spasticity associated with multiple musculoskeletal disorders. Future research should focus on portable and clinically applicable tools to measure active hamstring MTS in efforts to prevent and monitor injuries.

  3. Validation of a 4-item Negative Symptom Assessment (NSA-4): a short, practical clinical tool for the assessment of negative symptoms in schizophrenia.

    Science.gov (United States)

    Alphs, Larry; Morlock, Robert; Coon, Cheryl; Cazorla, Pilar; Szegedi, Armin; Panagides, John

    2011-06-01

    The 16-item Negative Symptom Assessment (NSA-16) scale is a validated tool for evaluating negative symptoms of schizophrenia. The psychometric properties and predictive power of a four-item version (NSA-4) were compared with the NSA-16. Baseline data from 561 patients with predominant negative symptoms of schizophrenia who participated in two identically designed clinical trials were evaluated. Ordered logistic regression analysis of ratings using NSA-4 and NSA-16 were compared with ratings using several other standard tools to determine predictive validity and construct validity. Internal consistency and test--retest reliability were also analyzed. NSA-16 and NSA-4 scores were both predictive of scores on the NSA global rating (odds ratio = 0.83-0.86) and the Clinical Global Impressions--Severity scale (odds ratio = 0.91-0.93). NSA-16 and NSA-4 showed high correlation with each other (Pearson r = 0.85), similar high correlation with other measures of negative symptoms (demonstrating convergent validity), and lesser correlations with measures of other forms of psychopathology (demonstrating divergent validity). NSA-16 and NSA-4 both showed acceptable internal consistency (Cronbach α, 0.85 and 0.64, respectively) and test--retest reliability (intraclass correlation coefficient, 0.87 and 0.82). This study demonstrates that NSA-4 offers accuracy comparable to the NSA-16 in rating negative symptoms in patients with schizophrenia. Copyright © 2011 John Wiley & Sons, Ltd.

  4. Translation and validation of the German version of the Bournemouth Questionnaire for Neck Pain

    Directory of Open Access Journals (Sweden)

    Soklic Marina

    2012-01-01

    Full Text Available Abstract Background Clinical outcome measures are important tools to monitor patient improvement during treatment as well as to document changes for research purposes. The short-form Bournemouth questionnaire for neck pain patients (BQN was developed from the biopsychosocial model and measures pain, disability, cognitive and affective domains. It has been shown to be a valid and reliable outcome measure in English, French and Dutch and more sensitive to change compared to other questionnaires. The purpose of this study was to translate and validate a German version of the Bournemouth questionnaire for neck pain patients. Methods German translation and back translation into English of the BQN was done independently by four persons and overseen by an expert committee. Face validity of the German BQN was tested on 30 neck pain patients in a single chiropractic practice. Test-retest reliability was evaluated on 31 medical students and chiropractors before and after a lecture. The German BQN was then assessed on 102 first time neck pain patients at two chiropractic practices for internal consistency, external construct validity, external longitudinal construct validity and sensitivity to change compared to the German versions of the Neck Disability Index (NDI and the Neck Pain and Disability Scale (NPAD. Results Face validity testing lead to minor changes to the German BQN. The Intraclass Correlation Coefficient for the test-retest reliability was 0.99. The internal consistency was strong for all 7 items of the BQN with Cronbach α's of .79 and .80 for the pre and post-treatment total scores. External construct validity and external longitudinal construct validity using Pearson's correlation coefficient showed statistically significant correlations for all 7 scales of the BQN with the other questionnaires. The German BQN showed greater responsiveness compared to the other questionnaires for all scales. Conclusions The German BQN is a valid and

  5. Use of a food frequency questionnaire to assess diets of Jamaican adults: validation and correlation with biomarkers

    Science.gov (United States)

    2011-01-01

    Background Assessment of habitual diet is important in investigations of diet-disease relationships. Many epidemiological studies use the food frequency questionnaire (FFQ) to evaluate dietary intakes but few studies validate the instrument against biological markers. The aim of this study was to assess the validity and reproducibility of a previously validated 70-item food frequency questionnaire (FFQ) that was expanded to 120-items to assess diet - cancer relations. Methods Relative validity of the FFQ was assessed against twelve 24-hour recalls administered over 12 months in 70 subjects. The FFQ was repeated after one year (FFQ2) to assess reproducibility. The validity of the FFQ was evaluated by comparing nutrient and food group intakes from 24-hour recalls with the first and second FFQ. In addition, FFQ validity for cholesterol and folate were determined through correlation with biomarkers (serum cholesterol, serum folate and whole blood folate) in 159 control subjects participating in a case-control prostate cancer study. Results Compared to recalls the FFQ tended to overestimate energy and carbohydrate intakes but gave no differences in intake for protein and fat. Quartile agreement for energy-adjusted nutrient intakes between FFQ2 and recalls ranged from 31.8% - 77.3% for the lowest quartile and 20.8% - 81.0% in the highest quartile. Gross misclassification of nutrients was low with the exceptions of protein, vitamin E and retinol and weighted kappa values ranged from 0.33 to 0.64 for other nutrients. Validity correlations for energy-adjusted nutrients (excluding retinol) were moderate to high (0.38- 0.86). Correlation coefficients between multiple recalls and FFQ1 ranged from 0.27 (fruits) to 0.55 (red meat); the second FFQ gave somewhat higher coefficients (0.30 to 0.61). Reproducibility correlations for the nutrients ranged from 0.50 to 0.84. Calibration of the FFQ with biochemical markers showed modest correlations with serum cholesterol (0.24), serum

  6. Measuring the suffering of end-stage dementia: reliability and validity of the Mini-Suffering State Examination.

    Science.gov (United States)

    Aminoff, Bechor Z; Purits, Elena; Noy, Shlomo; Adunsky, Abraham

    2004-01-01

    Assessment of suffering is extremely important in dying end-stage dementia patients (ESDP). We have developed and examined the reliability and validity of the Mini-Suffering State Examination (MSSE), in 103 consecutive bedridden ESDP. Main outcome measures included inter-observer reliability and concurrent validity. Reliability of the MSSE questionnaire was satisfactory, with Cronbach alpha values of 0.735 and 0.718 for the two physicians (Ph-1, Ph-2), respectively. The kappa agreement coefficient was 0.791. There was a high agreement for seven items (kappa 0.882-0.972) and a substantial agreement for the other three items (kappa 0.621-0.682) of the MSSE. MSSE was validated versus the comfort assessment in dying with dementia (CAD-EOLD) scale and resulted in a significant Pearson correlation (r=-0.796, P<0.001). We conclude that the MSSE scale is a reliable and valid clinical tool, recommended for evaluating the severity of the patient's condition and the level of suffering of ESDP. Use of MSSE may improve medical management and facilitate communication between patients and caregivers.

  7. The Brazilian version of the Constant-Murley Score (CMS-BR): convergent and construct validity, internal consistency, and unidimensionality.

    Science.gov (United States)

    Barreto, Rodrigo Py Gonçalves; Barbosa, Marcus Levi Lopes; Balbinotti, Marcos Alencar Abaide; Mothes, Fernando Carlos; da Rosa, Luís Henrique Telles; Silva, Marcelo Faria

    2016-01-01

    To translate and culturally adapt the CMS and assess the validity of the Brazilian version (CMS-BR). The translation was carried out according to the back-translation method by four independent translators. The produced versions were synthesized through extensive analysis and by consensus of an expert committee, reaching a final version used for the cultural adaptation. A field test was conducted with 30 subjects in order to obtain semantic considerations. For the psychometric analyzes, the sample was increased to 110 participants who answered two instruments: CMS-BR and the Disabilities of the Arm, shoulder and Hand (DASH). The CMS-BR and DASH score range from 0 to 100 points. For the first, higher points reflect better function and for the latter, the inverse is true. The validity was verified by Pearson's correlation test, the unidimensionality by factorial analysis, and the internal consistency by Cronbach's alpha. The explained variance was 60.28% with factor loadings ranging from 0.60 to 0.91. The CMS-BR exhibited strong negative correlation with the DASH score (-0.82, p  CMS was satisfactorily adapted for Brazilian Portuguese and demonstrated evidence of validity that allows its use in this population.

  8. Two-Way Gene Interaction From Microarray Data Based on Correlation Methods.

    Science.gov (United States)

    Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh

    2016-06-01

    Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman's rank correlation coefficient and Blomqvist's measure, and compared them with Pearson's correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson's correlation, Spearman's rank correlation, and Blomqvist's coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist's coefficient was not confirmed by visual methods. Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data.

  9. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    Science.gov (United States)

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  10. O princípio da homotipose em Karl Pearson: aspectos biológicos e estatísticos (1899 1906)

    OpenAIRE

    Venturineli, Katia Regina

    2010-01-01

    Karl Pearson (1857-1936) é geralmente conhecido por suas contribuições relacionadas à matemática e estatística. Entretanto, além disso, ele apresentou (em 1901 e 1902) uma proposta em relação à biologia: o princípio da homotipose. Para testá-lo, ele aplicou a estatística. A proposta de Pearson gerou uma discussão com William Bateson (1861-1926) e outros biólogos da época. O objetivo desta dissertação é inicialmente descrever a proposta de Pearson relativa ao princípio da ...

  11. Translation into Brazilian Portuguese, cross-cultural adaptation and validation of the Stanford presenteeism scale-6 and work instability scale for ankylosing spondylitis.

    Science.gov (United States)

    Frauendorf, Renata; de Medeiros Pinheiro, Marcelo; Ciconelli, Rozana Mesquita

    2014-12-01

    Loss of productivity at work, as a result of health problems, is becoming an issue of interest due to the high burden it represents in society. The measurement of such phenomenon can be made using generic and specific scales for certain diseases such as the Stanford Presenteeism Scale (SPS-6) and the Work Instability Scale for Ankylosing Spondylitis (AS-WIS), specific for patients with ankylosing spondylitis (AS). The aim of this study was to translate and perform a cross-cultural adaptation of SPS-6 and AS-WIS into Portuguese and check their psychometric properties. The study also aimed to evaluate the relationship between the general scores of the scales and the main sociodemographic and clinical data, lifestyles, and absenteeism in patients with AS and correlate these variables with SPS-6 and AS-WIS scales. A sample of 120 patients with AS and 80 workers at a university hospital was evaluated. The processes for the translation and cross-cultural adaptation of the instruments followed preestablished steps and rules presented in the literature. For the evaluation of measurement properties and correlations between scales, intra-class correlation coefficient (reproducibility analysis), Cronbach alpha (internal consistency), and Pearson correlation coefficient (validity) were employed. The inter-observer (0.986) and intra-observer (0.992) reproducibilities of the AS-WIS were shown to be high as well as the internal consistency (0.995). Similarly, the inter-observer reliability of SPS-6 was considered good (0.890), although it showed a poorer performance when considering the same observer (Pearson correlation coefficient = 0.675 and intra-class correlation = 0.656). Internal consistency, for the total number of items, as measured by Cronbach alpha, was 0.889. The validity of the scales was evaluated thru the comparison of the achieved scores with the results of the WLQ, SF-36, ASQoL, BASFI, BASDAI, HAQ-S, and SRQ-20 instruments. Correlations between loss of

  12. Donabedian's structure-process-outcome quality of care model: Validation in an integrated trauma system.

    Science.gov (United States)

    Moore, Lynne; Lavoie, André; Bourgeois, Gilles; Lapointe, Jean

    2015-06-01

    According to Donabedian's health care quality model, improvements in the structure of care should lead to improvements in clinical processes that should in turn improve patient outcome. This model has been widely adopted by the trauma community but has not yet been validated in a trauma system. The objective of this study was to assess the performance of an integrated trauma system in terms of structure, process, and outcome and evaluate the correlation between quality domains. Quality of care was evaluated for patients treated in a Canadian provincial trauma system (2005-2010; 57 centers, n = 63,971) using quality indicators (QIs) developed and validated previously. Structural performance was measured by transposing on-site accreditation visit reports onto an evaluation grid according to American College of Surgeons criteria. The composite process QI was calculated as the average sum of proportions of conformity to 15 process QIs derived from literature review and expert opinion. Outcome performance was measured using risk-adjusted rates of mortality, complications, and readmission as well as hospital length of stay (LOS). Correlation was assessed with Pearson's correlation coefficients. Statistically significant correlations were observed between structure and process QIs (r = 0.33), and process and outcome QIs (r = -0.33 for readmission, r = -0.27 for LOS). Significant positive correlations were also observed between outcome QIs (r = 0.37 for mortality-readmission; r = 0.39 for mortality-LOS and readmission-LOS; r = 0.45 for mortality-complications; r = 0.34 for readmission-complications; 0.63 for complications-LOS). Significant correlations between quality domains observed in this study suggest that Donabedian's structure-process-outcome model is a valid model for evaluating trauma care. Trauma centers that perform well in terms of structure also tend to perform well in terms of clinical processes, which in turn has a favorable influence on patient outcomes

  13. Adaptation and validation of the Spanish version of the Actinic Keratosis Quality of Life questionnaire.

    Science.gov (United States)

    Longo Imedio, Isabel; Serra-Guillén, Carlos

    2016-01-01

    While there are questionnaires for evaluating the effects of skin cancer on patient quality of life, there are no specific questionnaires available in Spanish for evaluating quality of life in patients with actinic keratosis. The aim of this study was to translate and culturally adapt the Actinic Keratosis Quality of Life (AKQoL) questionnaire into Spanish. The original questionnaire was translated into Spanish following the guidelines for the cross-cultural adaptation of self-report measures. Several measures of general reliability and validity were calculated, including Cronbach α for internal consistency and the Spearman rank-order correlation coefficient and a Bland-Altman plot for test-retest reliability. To test concurrent validity, we used the Pearson correlation coefficient to measure the correlation between AKQoL and Skindex-29 scores. The final version of the questionnaire was administered to 621 patients with actinic keratosis, who scored a mean (SD) of 5.25 (4.73) points (total possible score, 0-25). The Cronbach α reliability coefficient analysis was 0.84. The correlation between the mean (SD) score on the Skindex-29 (1.87 [4.07]) and on the AKQoL (1.97 [2.98] was 0.344 (P=.002, Spearman's rho), with a proportion of shared variance of 11.8%. The translation, cross-cultural adaptation, and validation of the original AKQoL produced a reliable, easily understandable questionnaire for evaluating the impact of actinic keratosis on the quality of life of patients in our setting. Copyright © 2016 AEDV. Published by Elsevier España, S.L.U. All rights reserved.

  14. Validation of the mother-generated index in Iran: A specific postnatal quality-of-life instrument

    Directory of Open Access Journals (Sweden)

    Roghayeh Khabiri

    2013-01-01

    Full Text Available Background: The mother-generated index (MGI is one of only a few existing specific questionnaires for assessing the postnatal quality of life (QoL. MGI is a single-form questionnaire that asks postnatal mothers to specify up to eight areas of their lives which have been affected by giving birth to a baby. Using this tool, it is possible to score and rank the QoL of mothers. This study aimed to validate the questionnaire for use in Iran. Methods : Forward translation was used to translate the questionnaire from English to Farsi (Persian. The questionnaire was then administered to a sample of postnatal women attending two teaching hospitals in Tehran, Iran. Face validity and criterion validity were performed to establish the validity for the Iranian version of the MGI. Face validity was assessed by asking women to indicate whether they understood the wording of the questions, how easy the questionnaire was, and so on. Criterion validity was examined using the Short Form 36-item (SF-36 Health Survey. It was hypothesized that the MGI would significantly correlate with the SF-36. Results: In all, 124 women were approached. Of these, 119 women were eligible and 96 women agreed to take part in the study. Face validity was good and all of the women found the MGI straightforward to complete; as criterion validity, the MGI scores and the subscales of the SF-36 were moderately correlated (for all subscales: Pearson r > 0.4; P < 0.001. The mean MGI primary score was 5.38 (SD = 3.05. Women who had comorbidity had significantly lower MGI scores than women without comorbidity (P = 0.04. Correlation between aggregate of comments and primary score was high (r = 0.68, P < 0.01. Conclusions: In general, the Iranian version of the MGI performed well and our data suggest that it is a valid measure to assess health-related QoL among postnatal women.

  15. Reliability and validity of the Wii Balance Board for assessment of standing balance: A systematic review.

    Science.gov (United States)

    Clark, Ross A; Mentiplay, Benjamin F; Pua, Yong-Hao; Bower, Kelly J

    2018-03-01

    The use of force platform technologies to assess standing balance is common across a range of clinical areas. Numerous researchers have evaluated the low-cost Wii Balance Board (WBB) for its utility in assessing balance, with variable findings. This review aimed to systematically evaluate the reliability and concurrent validity of the WBB for assessment of static standing balance. Articles were retrieved from six databases (Medline, SCOPUS, EMBASE, CINAHL, Web of Science, Inspec) from 2007 to 2017. After independent screening by two reviewers, 25 articles were included. Two reviewers performed the data extraction and quality assessment. Test-retest reliability was investigated in 12 studies, with intraclass correlation coefficients or Pearson's correlation values showing a range from poor to excellent reliability (range: 0.27 to 0.99). Concurrent validity (i.e. comparison with another force platform) was examined in 21 studies, and was generally found to be excellent in studies examining the association between the same outcome measures collected on both devices. For studies reporting predominantly poor to moderate validity, potentially influential factors included the choice of 1) criterion reference (e.g. not a common force platform), 2) test duration (e.g. balance. Protocol registration number: PROSPERO 2017: CRD42017058122. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Reliability and validity of the perspectives of Support From God Scale.

    Science.gov (United States)

    Hamilton, Jill B; Crandell, Jamie L; Carter, J Kameron; Lynn, Mary R

    2010-01-01

    Existing spiritual support scales for use with cancer survivors focus on the support believed to come from a religious community, clergy, or health care providers. The objective of this study was to evaluate the reliability and validity of a new measure of spiritual support believed to come from God in older Christian African American cancer survivors. The Perceived Support From God Scale was administered to 317 African American cancer survivors aged 55-89 years. Psychometric evaluation involved identifying underlying factors, conducting item analysis and estimating reliability, and obtaining evidence on the relationship to other variables or the extent to which the Perceived Support From God Scale correlates with religious involvement and depression. The Perceived Support From God Scale consists of 15 items in two subscales (Support From God and God's Purpose for Me). The two subscales explained 59% of the variance. Cronbach's alpha coefficients were .94 and .86 for the Support From God and God's Purpose for Me subscales, respectively. Test-retest correlations were strong, supporting the temporal stability of the instrument. Pearson's correlations to an existing religious involvement and beliefs scale were moderate to strong. Subscale scores on Support From God were negatively correlated to depression. Initial support for reliability and validity was demonstrated for the Perceived Support From God Scale. The scale captures a facet of spirituality not emphasized in other measures. Further research is needed to evaluate the scale with persons of other racial/ethnic groups and to explore the relationship of spirituality to other outcome measures.

  17. Improving Multidimensional Wireless Sensor Network Lifetime Using Pearson Correlation and Fractal Clustering.

    Science.gov (United States)

    Almeida, Fernando R; Brayner, Angelo; Rodrigues, Joel J P C; Maia, Jose E Bessa

    2017-06-07

    An efficient strategy for reducing message transmission in a wireless sensor network (WSN) is to group sensors by means of an abstraction denoted cluster. The key idea behind the cluster formation process is to identify a set of sensors whose sensed values present some data correlation. Nowadays, sensors are able to simultaneously sense multiple different physical phenomena, yielding in this way multidimensional data. This paper presents three methods for clustering sensors in WSNs whose sensors collect multidimensional data. The proposed approaches implement the concept of multidimensional behavioral clustering . To show the benefits introduced by the proposed methods, a prototype has been implemented and experiments have been carried out on real data. The results prove that the proposed methods decrease the amount of data flowing in the network and present low root-mean-square error (RMSE).

  18. Validity of Walk Score® as a measure of neighborhood walkability in Japan.

    Science.gov (United States)

    Koohsari, Mohammad Javad; Sugiyama, Takemi; Hanibuchi, Tomoya; Shibata, Ai; Ishii, Kaori; Liao, Yung; Oka, Koichiro

    2018-03-01

    Objective measures of environmental attributes have been used to understand how neighborhood environments relate to physical activity. However, this method relies on detailed spatial data, which are often not easily available. Walk Score® is a free, publicly available web-based tool that shows how walkable a given location is based on objectively-derived proximity to several types of local destinations and street connectivity. To date, several studies have tested the concurrent validity of Walk Score as a measure of neighborhood walkability in the USA and Canada. However, it is unknown whether Walk Score is a valid measure in other regions. The current study examined how Walk Score is correlated with objectively-derived attributes of neighborhood walkability, for residential addresses in Japan. Walk Scores were obtained for 1072 residential addresses in urban and rural areas in Japan. Five environmental attributes (residential density, intersection density, number of local destinations, sidewalk availability, and access to public transportation) were calculated using geographic information systems for each address. Pearson's correlation coefficients between Walk Score and these environmental attributes were calculated (conducted in May 2017). Significant positive correlations were observed between Walk Score and environmental attributes relevant to walking. Walk Score was most closely associated with intersection density ( r  = 0.82) and with the number of local destinations ( r  = 0.77). Walk Score appears to be a valid measure of neighborhood walkability in Japan. Walk Score will allow urban designers and public health practitioners to identify walkability of local areas without relying on detailed geographic data.

  19. Validation of the Quality-of-Life Questionnaire of the European Foundation for Osteoporosis (QUALEFFO-26) in Korean population.

    Science.gov (United States)

    Lee, Jung Sub; Shin, Jong Ki; Son, Seung Min; An, Sung Jin; Kang, Sung Shik

    2014-07-01

    We aimed to evaluate the reliability and validity of the adapted Korean version of the Quality-of-Life Questionnaire of the European Foundation for Osteoporosis (QUALEFFO-26). Translation/retranslation of the English version of QUALEFFO was conducted, and all steps of the cross-cultural adaptation process were performed. The Korean version of the visual analog scale measure of pain, QUALEFFO-26 and the previously validated Short Form-36 (SF-36) were mailed to 162 consecutive patients with osteoporosis. Factor analysis and reliability assessment by kappa statistics of agreement for each item, the intraclass correlation coefficient and Cronbach's α were conducted. Construct validity was also evaluated by comparing the responses of QUALEFFO-26 with the responses of SF-36 using Pearson's correlation coefficient. Factor analysis extracted 3 factors. All items had a kappa statistics of agreement greater than 0.6. The QUALEFFO-26 showed good test/retest reliability (QUALEFFO-26: 0.8271). Internal consistency of Cronbach's α was found to be very good (QUALEFFO-26: 0.873). The Korean version of QUALEFFO-26 showed good significant correlation with SF-36 total score and with single SF-36 domains scores. The adapted Korean version of the QUALEFFO-26 was successfully translated and showed acceptable measurement properties and, as such, is considered suitable for outcome assessments in the Korean-speaking patients with osteoporosis.

  20. Prentice Hall/Pearson Literature© (2007-15). What Works Clearinghouse Intervention Report

    Science.gov (United States)

    What Works Clearinghouse, 2017

    2017-01-01

    "Prentice Hall/Pearson Literature©" (2007-15) is an English language arts curriculum designed for students in grades 6-12 that focuses on building reading, vocabulary, literary analysis, and writing skills. It uses passages from fiction and nonfiction texts, poetry, and contemporary digital media. The curriculum is based on a textbook.…

  1. The Depressive Experiences Questionnaire: validity and psychological correlates in a clinical sample.

    Science.gov (United States)

    Riley, W T; McCranie, E W

    1990-01-01

    This study sought to compare the original and revised scoring systems of the Depressive Experiences Questionnaire (DEQ) and to assess the construct validity of the Dependent and Self-Critical subscales of the DEQ in a clinically depressed sample. Subjects were 103 depressed inpatients who completed the DEQ, the Beck Depression Inventory (BDI), the Hopelessness Scale, the Automatic Thoughts Questionnaire (ATQ), the Rathus Assertiveness Schedule (RAS), and the Minnesota Multiphasic Personality Inventory (MMPI). The original and revised scoring systems of the DEQ evidenced good concurrent validity for each factor scale, but the revised system did not sufficiently discriminate dependent and self-critical dimensions. Using the original scoring system, self-criticism was significantly and positively related to severity of depression, whereas dependency was not, particularly for males. Factor analysis of the DEQ scales and the other scales used in this study supported the dependent and self-critical dimensions. For men, the correlation of the DEQ with the MMPI scales indicated that self-criticism was associated with psychotic symptoms, hostility/conflict, and a distress/exaggerated response set, whereas dependency did not correlate significantly with any MMPI scales. Females, however, did not exhibit a differential pattern of correlations between either the Dependency or the Self-Criticism scales and the MMPI. These findings suggest possible gender differences in the clinical characteristics of male and female dependent and self-critical depressive subtypes.

  2. Correlation and simple linear regression.

    Science.gov (United States)

    Zou, Kelly H; Tuncali, Kemal; Silverman, Stuart G

    2003-06-01

    In this tutorial article, the concepts of correlation and regression are reviewed and demonstrated. The authors review and compare two correlation coefficients, the Pearson correlation coefficient and the Spearman rho, for measuring linear and nonlinear relationships between two continuous variables. In the case of measuring the linear relationship between a predictor and an outcome variable, simple linear regression analysis is conducted. These statistical concepts are illustrated by using a data set from published literature to assess a computed tomography-guided interventional technique. These statistical methods are important for exploring the relationships between variables and can be applied to many radiologic studies.

  3. Reproducibility and validity of the food frequency questionnaire for estimating habitual dietary intake in children and adolescents

    Science.gov (United States)

    2011-01-01

    Background A previous study reported the development a 75-item food frequency questionnaire for Japanese children (CFFQ). The first aim was to examine the reproducibility and validity of the CFFQ in order to assess dietary intake among two groups; 3-11 year old children (YC group) and 12-16 year old children (AD group). The second aim was to use the CFFQ and the FFQ for adults (AFFQ), and to determine which was better suited for assessing the intake of children in each group. Methods A total of the 103 children participated in this study. The interval between the first CFFQ and AFFQ and the second CFFQ and AFFQ was one month. Four weighted dietary records (WDRs) were conducted once a week. Pearson's correlation coefficients between the first and second FFQs were calculated to test the reproducibility of each FFQ. Pearson's correlation coefficients between WDRs and the second FFQ were calculated for the unadjusted value and sex-, age-, and energy-adjusted values to determine the validity of each FFQ. Results The final number of subjects participating in the analysis was 89. The median correlation coefficients between the first and second CFFQs and AFFQs were 0.76 and 0.73, respectively. There was some over/underestimation of nutrients in the CFFQ of the YC group and in the AFFQ of the AD group. The medians of the sex-, age-, and energy-adjusted correlation coefficients were not different between the YC and AD groups for each FFQ. The correlation coefficient in sex-, age-, and energy-adjusted value revealed that the largest number of subject with high (0.50 or more) value was obtained by the CFFQ in the YC group. Conclusions This study indicated that the CFFQ might be a useful tool for assessing habitual dietary intake of children in the YC group. Although the CFFQ agreed moderately with habitual intake, it was found to underestimate intake in theAD group. However, for the AFFQ, the ability to rank habitual intake was low. Therefore, it is necessary to develop a new

  4. External Validation of the Prestroke Independence, Sex, Age, National Institutes of Health Stroke Scale Score for Predicting Pneumonia After Stroke Using Data From the China National Stroke Registry.

    Science.gov (United States)

    Zhang, Runhua; Ji, Ruijun; Pan, Yuesong; Jiang, Yong; Liu, Gaifen; Wang, Yilong; Wang, Yongjun

    2017-05-01

    Pneumonia is an important risk factor for mortality and morbidity after stroke. The Prestroke Independence, Sex, Age, National Institutes of Health Stroke Scale (ISAN) score was shown to be a useful tool for predicting stroke-associated pneumonia based on UK multicenter cohort study. We aimed to externally validate the score using data from the China National Stroke Registry (CNSR). Eligible patients with acute ischemic stroke (AIS) and intracerebral hemorrhage (ICH) in the CNSR from 2007 to 2008 were included. The area under the receiver operating characteristic (AUC) curve was used to evaluate discrimination. The Hosmer-Lemeshow goodness of fit test and Pearson correlation coefficient were performed to assess calibration of the model. A total of 19,333 patients (AIS = 14400; ICH = 4933) were included and the overall pneumonia rate was 12.7%. The AUC was .76 (95% confidence interval [CI]: .75-.78) for the subgroup of AIS and .70 (95% CI: .68-.72) for the subgroup of ICH. The Hosmer-Lemeshow test showed the ISAN score with the good calibration for AIS and ICH (P = .177 and .405, respectively). The plot of observed versus predicted pneumonia rates suggested higher correlation for patients with AIS than with ICH (Pearson correlation coefficient = .99 and .83, respectively). The ISAN score was a useful tool for predicting in-hospital pneumonia after acute stroke, especially for patients with AIS. Further validations need to be done in different populations. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  5. Validation of a maternal questionnaire on correlates of physical activity in preschool children

    Directory of Open Access Journals (Sweden)

    Inskip Hazel M

    2009-12-01

    Full Text Available Abstract Background Valid measures of physical activity correlates in preschool children are lacking. This study aimed to assess the validity, factor structure and internal consistency of a maternal questionnaire on potential correlates of four-year-old children's physical activity. Methods The questionnaire was designed to measure the following constructs: child personal factors; parental support and self-efficacy for providing support; parental rules and restrictions; maternal attitudes and perceptions; maternal behaviour; barriers to physical activity; and the home and local environments. Two separate studies were conducted. Study I included 24 mothers of four-year-old children who completed the questionnaire then participated in a telephone interview covering similar items to the questionnaire. To assess validity, the agreement between interview and questionnaire responses was assessed using Cohen's kappa and percentage agreement. Study II involved 398 mothers of four-year-old children participating in the Southampton Women's Survey. In this study, principal components analysis was used to explore the factor structure of the questionnaire to aid future analyses with these data. The internal consistency of the factors identified was assessed using Cronbach's alpha. Results Kappa scores showed 30% of items to have moderate agreement or above, 23% to have fair agreement and 47% to have slight or poor agreement. However, 89% of items had fair agreement as assessed by percentage agreement (≥ 66%. Limited variation in responses to variables is likely to have contributed to some of the low kappa values. Six questions had a low kappa and low percentage agreement (defined as poor validity; these included questions from the child personal factors, maternal self-efficacy, rules and restrictions, and local environment domains. The principal components analysis identified eleven factors and found several variables to stand alone. Eight of the composite

  6. Correlation and agreement of a digital and conventional method to measure arch parameters.

    Science.gov (United States)

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  7. Validity of clinical outcome measures to evaluate ankle range of motion during the weight-bearing lunge test.

    Science.gov (United States)

    Hall, Emily A; Docherty, Carrie L

    2017-07-01

    To determine the concurrent validity of standard clinical outcome measures compared to laboratory outcome measure while performing the weight-bearing lunge test (WBLT). Cross-sectional study. Fifty participants performed the WBLT to determine dorsiflexion ROM using four different measurement techniques: dorsiflexion angle with digital inclinometer at 15cm distal to the tibial tuberosity (°), dorsiflexion angle with inclinometer at tibial tuberosity (°), maximum lunge distance (cm), and dorsiflexion angle using a 2D motion capture system (°). Outcome measures were recorded concurrently during each trial. To establish concurrent validity, Pearson product-moment correlation coefficients (r) were conducted, comparing each dependent variable to the 2D motion capture analysis (identified as the reference standard). A higher correlation indicates strong concurrent validity. There was a high correlation between each measurement technique and the reference standard. Specifically the correlation between the inclinometer placement at 15cm below the tibial tuberosity (44.9°±5.5°) and the motion capture angle (27.0°±6.0°) was r=0.76 (p=0.001), between the inclinometer placement at the tibial tuberosity angle (39.0°±4.6°) and the motion capture angle was r=0.71 (p=0.001), and between the distance from the wall clinical measure (10.3±3.0cm) to the motion capture angle was r=0.74 (p=0.001). This study determined that the clinical measures used during the WBLT have a high correlation with the reference standard for assessing dorsiflexion range of motion. Therefore, obtaining maximum lunge distance and inclinometer angles are both valid assessments during the weight-bearing lunge test. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  8. The influence of base rates on correlations: An evaluation of proposed alternative effect sizes with real-world data.

    Science.gov (United States)

    Babchishin, Kelly M; Helmus, Leslie-Maaike

    2016-09-01

    Correlations are the simplest and most commonly understood effect size statistic in psychology. The purpose of the current paper was to use a large sample of real-world data (109 correlations with 60,415 participants) to illustrate the base rate dependence of correlations when applied to dichotomous or ordinal data. Specifically, we examined the influence of the base rate on different effect size metrics. Correlations decreased when the dichotomous variable did not have a 50 % base rate. The higher the deviation from a 50 % base rate, the smaller the observed Pearson's point-biserial and Kendall's tau correlation coefficients. In contrast, the relationship between base rate deviations and the more commonly proposed alternatives (i.e., polychoric correlation coefficients, AUCs, Pearson/Thorndike adjusted correlations, and Cohen's d) were less remarkable, with AUCs being most robust to attenuation due to base rates. In other words, the base rate makes a marked difference in the magnitude of the correlation. As such, when using dichotomous data, the correlation may be more sensitive to base rates than is optimal for the researcher's goals. Given the magnitude of the association between the base rate and point-biserial correlations (r = -.81) and Kendall's tau (r = -.80), we recommend that AUCs, Pearson/Thorndike adjusted correlations, Cohen's d, or polychoric correlations should be considered as alternate effect size statistics in many contexts.

  9. Criterion and Divergent Validity of the Sexual Minority Adolescent Stress Inventory

    Directory of Open Access Journals (Sweden)

    Jeremy T. Goldbach

    2017-11-01

    Full Text Available Sexual minority adolescents (SMA consistently report health disparities compared to their heterosexual counterparts, yet the underlying mechanisms of these negative health outcomes remain unclear. The predominant explanatory model is the minority stress theory; however, this model was developed largely with adults, and no valid and comprehensive measure of minority stress has been developed for adolescents. The present study validated a newly developed instrument to measure minority stress among racially and ethnically diverse SMA. A sample of 346 SMA aged 14–17 was recruited and surveyed between February 2015 and July 2016. The focal measure of interest was the 64-item, 11-factor Sexual Minority Adolescent Stress Inventory (SMASI developed in the initial phase of this study. Criterion validation measures included measures of depressive symptoms, suicidality and self-harm, youth problem behaviors, and substance use; the general Adolescent Stress Questionnaire (ASQ was included as a measure of divergent validity. Analyses included Pearson and tetrachoric correlations to establish criterion and divergent validity and structural equation modeling to assess the explanatory utility of the SMASI relative to the ASQ. SMASI scores were significantly associated with all outcomes but only moderately associated with the ASQ (r = −0.13 to 0.51. Analyses revealed significant associations of a latent minority stress variable with both proximal and distal health outcomes beyond the variation explained by general stress. Results show that the SMASI is the first instrument to validly measure minority stress among SMA.

  10. Validity of the German Version of the Continuous-Scale Physical Functional Performance 10 Test

    Directory of Open Access Journals (Sweden)

    Irene Härdi

    2017-01-01

    Full Text Available Background. The Continuous-Scale Physical Functional Performance 10 Test (CS-PFP 10 quantitatively assesses physical functional performance in older adults who have a broad range of physical functional ability. This study assessed the validity and reliability of the CS-PFP 10 German version. Methods. Forward-translations and backtranslations as well as cultural adaptions of the test were conducted. Participants were German-speaking Swiss community-dwelling adults aged 64 and older. Concurrent validity was assessed using Pearson correlation coefficients between CS-PFP 10 and gait velocity, Timed Up and Go Test, hand grip strength, SF-36 physical function domain, and Freiburger Physical Activity Questionnaire. Internal consistency was calculated by Cronbach’s alpha. Results. Backtranslation and cultural adaptions were accepted by the CS-PFP 10 developer. CS-PFP 10 total score and subscores (upper body strength, upper body flexibility, lower body strength, balance and coordination, and endurance correlated significantly with all measures of physical function tested. Internal consistency was high (Cronbach’s alpha 0.95–0.98. Conclusion. The CS-PFP 10 German version is valid and reliable for measuring physical functional performance in German-speaking Swiss community-dwelling older adults. Quantifying physical function is essential for clinical practice and research and provides meaningful insight into physical functional performance of older adults. This trial is registered with ClinicalTrials.gov NCT01539200.

  11. [Lack of correlation between performances in a simulator and in reality].

    Science.gov (United States)

    Konge, Lars; Bitsch, Mikael

    2010-12-13

    Simulation-based training provides obvious benefits for patients and doctors in education. Frequently, virtual reality simulators are expensive and evidence for their efficacy is poor, particularly as a result of studies with poor methodology and few test participants. In medical simulated training- and evaluation programmes it is always a question of transfer to the real clinical world. To illustrate this problem a study comparing the test performance of persons on a bowling simulator with their performance in a real bowling alley was conducted. Twenty-five test subjects played two rounds of bowling on a Nintendo Wii and 25 days later on a real bowling alley. Correlations of the scores in the first and second round (test-retest-reliability) and of the scores on the simulator and in reality (criterion validation) were studied and there was tested for any difference between female and male performance. The intraclass correlation coefficient equalled 0.76, i.e. the simulator fairly accurately measured participant performance. In contrast to this there was absolutely no correlation between participants' real bowling abilities and their scores on the simulator (Pearson's r = 0.06). There was no significant difference between female and male abilities. Simulation-based testing and training must be based on evidence. More studies are needed to include an adequate number of subjects. Bowling competence should not be based on Nintendo Wii measurements. Simulated training- and evaluation programmes should be validated before introduction, to ensure consistency with the real world.

  12. Toddler physical activity study: laboratory and community studies to evaluate accelerometer validity and correlates

    Directory of Open Access Journals (Sweden)

    Erin R. Hager

    2016-09-01

    Full Text Available Abstract Background Toddlerhood is an important age for physical activity (PA promotion to prevent obesity and support a physically active lifestyle throughout childhood. Accurate assessment of PA is needed to determine trends/correlates of PA, time spent in sedentary, light, or moderate-vigorous PA (MVPA, and the effectiveness of PA promotion programs. Due to the limited availability of objective measures that have been validated and evaluated for feasibility in community studies, it is unclear which subgroups of toddlers are at the highest risk for inactivity. Using Actical ankle accelerometry, the objectives of this study are to develop valid thresholds, examine feasibility, and examine demographic/ anthropometric PA correlates of MVPA among toddlers from low-income families. Methods Two studies were conducted with toddlers (12–36 months. Laboratory Study (n = 24- Two Actical accelerometers were placed on the ankle. PA was observed using the Child Activity Rating Scale (CARS, prescribed activities. Analyses included device equivalence reliability (correlation: activity counts of two Acticals, criterion-related validity (correlation: activity counts and CARS ratings, and sensitivity/specificity for thresholds. Community Study (n = 277, low-income mother-toddler dyads recruited- An Actical was worn on the ankle for > 7 days (goal >5, 24-h days. Height/weight was measured. Mothers reported demographics. Analyses included frequencies (feasibility and stepwise multiple linear regression (sMLR. Results Laboratory Study- Acticals demonstrated reliability (r = 0.980 and validity (r = 0.75. Thresholds demonstrated sensitivity (86 % and specificity (88 %. Community Study- 86 % wore accelerometer, 69 % had valid data (mean = 5.2 days. Primary reasons for missing/invalid data: refusal (14 % and wear-time ≤2 days (11 %. The MVPA threshold (>2200 cpm yielded 54 min/day. In sMLR, MVPA was associated with age (older

  13. An inequality between the weighted average and the rowwise correlation coefficient for proximity matrices

    NARCIS (Netherlands)

    Krijnen, WP

    De Vries (1993) discusses Pearson's product-moment correlation, Spearman's rank correlation, and Kendall's rank-correlation coefficient for assessing the association between the rows of two proximity matrices. For each of these he introduces a weighted average variant and a rowwise variant. In this

  14. AN INEQUALITY BETWEEN THE WEIGHTED AVERAGE AND THE ROWWISE CORRELATION-COEFFICIENT FOR PROXIMITY MATRICES

    NARCIS (Netherlands)

    KRIJNEN, WP

    De Vries (1993) discusses Pearson's product-moment correlation, Spearman's rank correlation, and Kendall's rank-correlation coefficient for assessing the association between the rows of two proximity matrices. For each of these he introduces a weighted average variant and a rowwise variant. In this

  15. Validation of the DRAGON Score in a Chinese Population to Predict Functional Outcome of Intravenous Thrombolysis-Treated Stroke Patients.

    Science.gov (United States)

    Zhang, Xinmiao; Liao, Xiaoling; Wang, Chunjuan; Liu, Liping; Wang, Chunxue; Zhao, Xingquan; Pan, Yuesong; Wang, Yilong; Wang, Yongjun

    2015-08-01

    The DRAGON score predicts functional outcome of ischemic stroke patients treated with intravenous thrombolysis. Our aim was to evaluate its utility in a Chinese stroke population. Patients with acute ischemic stroke treated with intravenous thrombolysis were prospectively registered in the Thrombolysis Implementation and Monitor of acute ischemic Stroke in China. We excluded patients with basilar artery occlusion and missing data, leaving 970 eligible patients. We calculated the DRAGON score, and the clinical outcome was measured by the modified Rankin Scale at 3 months. Model discrimination was quantified by calculating the C statistic. Calibration was assessed using Pearson correlation coefficient. The C statistic was .73 (.70-.76) for good outcome and .75 (.70-.79) for miserable outcome. Proportions of patients with good outcome were 94%, 83%, 70%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 3%, 9%, and 50% for 0 to 1, 2, 3, and 8 to 10 points, respectively. There was high correlation between predicted and observed probability of 3-month favorable and miserable outcome in the external validation cohort (Pearson correlation coefficient, .98 and .98, respectively, both P DRAGON score showed good performance to predict functional outcome after tissue-type plasminogen activator treatment in the Chinese population. This study demonstrated the accuracy and usability of the DRAGON score in the Chinese population in daily practice. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  16. Management Of Large Scale Osmotic Dehydration Solution Using The Pearsons Square Algorithm

    Directory of Open Access Journals (Sweden)

    Oladejo Duduyemi

    2015-01-01

    Full Text Available ABSTRACT Osmotic dehydration is a widely researched and advantageous pre-treatment process in food preservation but has not enjoyed industrial acceptance because if its highly concentrated and voluminous effluent. The Pearsons square algorithm was employed to give a focussed attack to the problem by developing a user-friendly template for reconstituting effluents for recycling purposes using Java script programme. Outflow from a pilot scale plant was reactivated and introduced into a scheme of operation for continuous OD of fruits and vegetables. Screened and re-concentrated effluent were subjected to statistical analysis in comparison to initial concentrations solution at confidence limit of p0.05. The template proven to be an adequate representation of the Pearsons square algorithm it is sufficiently good in reconstituting used osmotic solutions for repetitive usage. This protocol if adopted in the industry is not only environmentally friendly but also promises significant economic improvement of OD process. Application Recycling of non-reacting media and as a template for automation in continuous OD processing.

  17. Validation of the Pregnancy Physical Activity Questionnaire (PPAQ

    Directory of Open Access Journals (Sweden)

    Edyta Suliga

    2017-03-01

    Full Text Available Introduction : The results of many studies confirm the positive effect of physical activity during pregnancy on the health of both mother and child. Due to this, it is important to use standardised methods of its assessment. In 2004, Chasan-Taber et al. developed the Pregnancy Physical Activity Questionnaire (PPAQ, taking into account household/caregiving activities, occupational activities, sports/exercise activities, transportation activities, and inactivity. Aim of the research : The validation of the Pregnancy Physical Activity Questionnaire (PPAQ by determination of its reproducibility. Material and methods : The questionnaire was validated from June 2014 to February 2015 among 164 women. The respondents were surveyed twice in a 2-week interval. The repeatability of the questionnaire was verified by determining the Pearson correlation coefficient between the results obtained for the same people in the first and second interview, thus determining the intra-subject variability. Inter-subject variability was analysed by comparing the average values of physical activity for the whole group using the Student’s t-test for dependent samples. Results : For all levels of physical activity, a high correlation between the results obtained in both interviews was found. The correlation coefficient for total physical activity was r = 0.96. The reproducibility of the results obtained from PPAQ questionnaire was the highest for inactivity and moderate activity (r = 0.96. The analysis according to the type of activity showed that the reproducibility was the highest for occupational activity (r = 0.98. Conclusions : High reproducibility of results obtained using PPAQ questionnaire was found. This allows the assessed questionnaire to be considered as an accurate measurement tool that can be a source of reliable information about physical activity in pregnant women.

  18. Environmental education curriculum evaluation questionnaire: A reliability and validity study

    Science.gov (United States)

    Minner, Daphne Diane

    The intention of this research project was to bridge the gap between social science research and application to the environmental domain through the development of a theoretically derived instrument designed to give educators a template by which to evaluate environmental education curricula. The theoretical base for instrument development was provided by several developmental theories such as Piaget's theory of cognitive development, Developmental Systems Theory, Life-span Perspective, as well as curriculum research within the area of environmental education. This theoretical base fueled the generation of a list of components which were then translated into a questionnaire with specific questions relevant to the environmental education domain. The specific research question for this project is: Can a valid assessment instrument based largely on human development and education theory be developed that reliably discriminates high, moderate, and low quality in environmental education curricula? The types of analyses conducted to answer this question were interrater reliability (percent agreement, Cohen's Kappa coefficient, Pearson's Product-Moment correlation coefficient), test-retest reliability (percent agreement, correlation), and criterion-related validity (correlation). Face validity and content validity were also assessed through thorough reviews. Overall results indicate that 29% of the questions on the questionnaire demonstrated a high level of interrater reliability and 43% of the questions demonstrated a moderate level of interrater reliability. Seventy-one percent of the questions demonstrated a high test-retest reliability and 5% a moderate level. Fifty-five percent of the questions on the questionnaire were reliable (high or moderate) both across time and raters. Only eight questions (8%) did not show either interrater or test-retest reliability. The global overall rating of high, medium, or low quality was reliable across both coders and time, indicating

  19. Assessing the reliability and validity of anti-tobacco attitudes/beliefs in the context of a campaign strategy.

    Science.gov (United States)

    Arheart, Kristopher L; Sly, David F; Trapido, Edward J; Rodriguez, Richard D; Ellestad, Amy J

    2004-11-01

    To identify multi-item attitude/belief scales associated with the theoretical foundations of an anti-tobacco counter-marketing campaign and assess their reliability and validity. The data analyzed are from two state-wide, random, cross-sectional telephone surveys [n(S1)=1,079, n(S2)=1,150]. Items forming attitude/belief scales are identified using factor analysis. Reliability is assessed with Chronbach's alpha. Relationships among scales are explored using Pearson correlation. Validity is assessed by testing associations derived from the Centers for Disease Control and Prevention's (CDC) logic model for tobacco control program development and evaluation linking media exposure to attitudes/beliefs, and attitudes/beliefs to smoking-related behaviors. Adjusted odds ratios are employed for these analyses. Three factors emerged: traditional attitudes/beliefs about tobacco and tobacco use, tobacco industry manipulation and anti-tobacco empowerment. Reliability coefficients are in the range of 0.70 and vary little between age groups. The factors are correlated with one-another as hypothesized. Associations between media exposure and the attitude/belief scales and between these scales and behaviors are consistent with the CDC logic model. Using reliable, valid multi-item scales is theoretically and methodologically more sound than employing single-item measures of attitudes/beliefs. Methodological, theoretical and practical implications are discussed.

  20. Validity and Reliability of a Portable Balance Tracking System, BTrackS, in Older Adults.

    Science.gov (United States)

    Levy, Susan S; Thralls, Katie J; Kviatkovsky, Shiloah A

    Falls are the leading cause of disability, injury, hospital admission, and injury-related death among older adults. Balance limitations have consistently been identified as predictors of falls and increased fall risk. Field measures of balance are limited by issues of subjectivity, ceiling effects, and low sensitivity to change. The gold standard for measuring balance is the force plate; however, its field use is untenable due to high cost and lack of portability. Thus, a critical need is observed for valid objective field measures of balance to accurately assess balance and identify limitations over time. The purpose of this study was to examine the concurrent validity and 3-day test-retest reliability of Balance Tracking System (BTrackS) in community-dwelling older adults. Minimal detectable change values were also calculated to reflect changes in balance beyond measurement error. Postural sway data were collected from community-dwelling older adults (N = 49, mean [SD] age = 71.3 [7.3] years) with a force plate and BTrackS in multitrial eyes open (EO) and eyes closed (EC) static balance conditions. Force sensors transmitted BTrackS data via a USB to a computer running custom software. Three approaches to concurrent validity were taken including calculation of Pearson product moment correlation coefficients, repeated-measures ANOVAs, and Bland-Altman plots. Three-day test-retest reliability of BTrackS was examined in a second sample of 47 community-dwelling older adults (mean [SD] age = 75.8 [7.7] years) using intraclass correlation coefficients and MDC values at 95% CI (MDC95) were calculated. BTrackS demonstrated good validity using Pearson product moment correlations (r > 0.90). Repeated-measures ANOVA and Bland-Altman plots indicated some BTrackS bias with center of pressure (COP) values higher than FP COP values in the EO (mean [SD] bias = 4.0 [6.8]) and EC (mean [SD] bias = 9.6 [12.3]) conditions. Test-retest reliability using intraclass correlation

  1. The Classroom Environment Questionnaire (CEQ): Development and preliminary structural validity.

    Science.gov (United States)

    Lyons, Carissa; Brown, Ted; Bourke-Taylor, Helen

    2018-04-16

    Occupational therapists offer a unique perspective regarding the contribution of the environment to occupational performance. Therefore, a scale that measures the unique characteristics of the primary school classroom environment where children complete their daily schoolwork occupations is needed. The aim of this study was to develop and psychometrically evaluate a new teacher-report questionnaire that measures a number of environmental characteristics of primary school classrooms. Participants (N = 117) completed the Classroom Environment Questionnaire (CEQ), which utilises a 4-point Likert scale where teachers rate 51 environmental characteristics of their classroom. Teachers also rate the extent to which they believe the physical, social, temporal, institutional and cultural classroom environmental domains contribute to students' schoolwork performance using a 10-point scale. The structural validity of the CEQ was examined using principal component analysis (PCA). Inter-item correlations were examined using Pearson r correlations, while the internal consistency of the CEQ was assessed using Cronbach's alpha. PCA revealed the CEQ to be multidimensional, with 31 items loading onto nine viable factors, representing the unique nature of classroom environments. Based on the PCA results, 20 items were removed from the CEQ. Cronbach's alpha and correlation analysis indicated that most CEQ subsections had acceptable internal consistency (alpha range 0.70-0.82), with four subsections demonstrating a lower level of internal consistency (alpha range 0.55-0.69). Preliminary structural validity and internal consistency analysis findings confirm that the CEQ has potential to be a useful scale for professionals wishing to examine the unique characteristics of primary school classrooms that influence the occupational performance of students. Ongoing analyses will be undertaken to further explore the CEQ's validity and reliability. © 2018 Occupational Therapy Australia.

  2. Reproducibility and relative validity of a food-frequency questionnaire for French-speaking Swiss adults

    Directory of Open Access Journals (Sweden)

    Pedro Marques-Vidal

    2011-05-01

    Full Text Available Background : Due to the distinct cultural and language differences that exist in Switzerland, there is little information on the dietary intake among the general Swiss population. Adequately assessing dietary intake is thus paramount if nutritional epidemiological studies are to be conducted. Objective : To assess the reproducibility and validity of a food-frequency questionnaire (FFQ developed for French-speaking Swiss adults. Design : A total of 23 men and 17 women (43.1±2.0 years filled out one FFQ and completed one 24-hour dietary recall at baseline and 1 month afterward. Results : Crude Pearson's correlation coefficients between the first and the second FFQ ranged from 0.58 to 0.90, intraclass correlation coefficient (ICC ranged between 0.53 and 0.92. Lin's concordance coefficients ranged between 0.55 and 0.87. Over 80% of participants were classified in the same or adjacent tertile using each FFQ. Macronutrient intakes estimated by both FFQs were significantly higher than those estimated from the 24-hour recall for protein and water, while no significant differences were found for energy, carbohydrate, fats (five groups, and alcohol. De-attenuated Pearson's correlation coefficients between the 24-hour recall and the first FFQ ranged between 0.31 and 0.49, while for the second FFQ the values ranged between 0.38 and 0.59. Over 40 and 95% of participants fell into the same or the adjacent energy and nutrient tertiles, respectively, using the FFQs and the 24-hour recall. Conclusions : This FFQ shows good reproducibility and can be used determining macronutrient intake in a French-speaking Swiss population in an epidemiological setting.

  3. Validating hospital antibiotic purchasing data as a metric of inpatient antibiotic use.

    Science.gov (United States)

    Tan, Charlie; Ritchie, Michael; Alldred, Jason; Daneman, Nick

    2016-02-01

    Antibiotic purchasing data are a widely used, but unsubstantiated, measure of antibiotic consumption. To validate this source, we compared purchasing data from hospitals and external medical databases with patient-level dispensing data. Antibiotic purchasing and dispensing data from internal hospital records and purchasing data from IMS Health were obtained for two hospitals between May 2013 and April 2015. Internal purchasing data were validated against dispensing data, and IMS data were compared with both internal metrics. Scatterplots of individual antimicrobial data points were generated; Pearson's correlation and linear regression coefficients were computed. A secondary analysis re-examined these correlations over shorter calendar periods. Internal purchasing data were strongly correlated with dispensing data, with correlation coefficients of 0.90 (95% CI = 0.83-0.95) and 0.98 (95% CI = 0.95-0.99) at hospitals A and B, respectively. Although dispensing data were consistently lower than purchasing data, this was attributed to a single antibiotic at both hospitals. IMS data were favourably correlated with, but underestimated, internal purchasing and dispensing data. This difference was accounted for by eight antibiotics for which direct sales from some manufacturers were not included in the IMS database. The correlation between purchasing and dispensing data was consistent across periods as short as 3 months, but not at monthly intervals. Both internal and external antibiotic purchasing data are strongly correlated with dispensing data. If outliers are accounted for appropriately, internal purchasing data could be used for cost-effective evaluation of antimicrobial stewardship programmes, and external data sets could be used for surveillance and research across geographical regions. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e

  4. Bayesian Correlation Analysis for Sequence Count Data.

    Directory of Open Access Journals (Sweden)

    Daniel Sánchez-Taltavull

    Full Text Available Evaluating the similarity of different measured variables is a fundamental task of statistics, and a key part of many bioinformatics algorithms. Here we propose a Bayesian scheme for estimating the correlation between different entities' measurements based on high-throughput sequencing data. These entities could be different genes or miRNAs whose expression is measured by RNA-seq, different transcription factors or histone marks whose expression is measured by ChIP-seq, or even combinations of different types of entities. Our Bayesian formulation accounts for both measured signal levels and uncertainty in those levels, due to varying sequencing depth in different experiments and to varying absolute levels of individual entities, both of which affect the precision of the measurements. In comparison with a traditional Pearson correlation analysis, we show that our Bayesian correlation analysis retains high correlations when measurement confidence is high, but suppresses correlations when measurement confidence is low-especially for entities with low signal levels. In addition, we consider the influence of priors on the Bayesian correlation estimate. Perhaps surprisingly, we show that naive, uniform priors on entities' signal levels can lead to highly biased correlation estimates, particularly when different experiments have widely varying sequencing depths. However, we propose two alternative priors that provably mitigate this problem. We also prove that, like traditional Pearson correlation, our Bayesian correlation calculation constitutes a kernel in the machine learning sense, and thus can be used as a similarity measure in any kernel-based machine learning algorithm. We demonstrate our approach on two RNA-seq datasets and one miRNA-seq dataset.

  5. The validity and reliability of the Persian version of the Revised Fibromyalgia Impact Questionnaire.

    Science.gov (United States)

    Ghavidel Parsa, Banafsheh; Amir Maafi, Alireza; Haghdoost, Afrooz; Arabi, Yasaman; Khojamli, Monire; Chatrnour, Gelayol; Bidari, Ali

    2014-02-01

    The Revised Fibromyalgia Impact Questionnaire (FIQR), an updated version of the Fibromyalgia Impact Questionnaire (FIQ) achieved a better balance among different domains (i.e., function, overall impact, and symptom severity) and attempts to address the limitations of FIQ. As there is no Persian version of the FIQR available, we aimed to investigate the validity and reliability of a Persian translation of the FIQR in Iranian patients. After translating the FIQR into Persian, it was administered to 77 female patients with fibromyalgia syndrome. All of the patients filled out the questionnaire together with a Persian version of the FIQ, short form-12 (SF-12). The tender-point count was also calculated. One week later, FM patients filled out the Persian FIQR at their second visit. Reliability was analyzed by internal consistency and reproducibility including Cronbach's α coefficient and intra-class correlation coefficient. Construct validity was evaluated by Spearman's correlation coefficient and Pearson's correlation coefficient. Statistical analysis was performed using SPSS for Windows version 17.0. All patients included in this study were female, and the mean age was 38.23 ± 10.68 years. The total scores of the FIQR and FIQ were 49.77 ± 18.27 and 54.05 ± 14.00 that were closely correlated (r = 0.63, p FIQ domains (r = 0.36-0.63, p fibromyalgia.

  6. Performance evaluation for epileptic electroencephalogram (EEG) detection by using Neyman-Pearson criteria and a support vector machine

    Science.gov (United States)

    Wang, Chun-mei; Zhang, Chong-ming; Zou, Jun-zhong; Zhang, Jian

    2012-02-01

    The diagnosis of several neurological disorders is based on the detection of typical pathological patterns in electroencephalograms (EEGs). This is a time-consuming task requiring significant training and experience. A lot of effort has been devoted to developing automatic detection techniques which might help not only in accelerating this process but also in avoiding the disagreement among readers of the same record. In this work, Neyman-Pearson criteria and a support vector machine (SVM) are applied for detecting an epileptic EEG. Decision making is performed in two stages: feature extraction by computing the wavelet coefficients and the approximate entropy (ApEn) and detection by using Neyman-Pearson criteria and an SVM. Then the detection performance of the proposed method is evaluated. Simulation results demonstrate that the wavelet coefficients and the ApEn are features that represent the EEG signals well. By comparison with Neyman-Pearson criteria, an SVM applied on these features achieved higher detection accuracies.

  7. Validity and reliability of the Japanese version of the Caregiver Reaction Assessment Scale (CRA-J) for community-dwelling cancer patients.

    Science.gov (United States)

    Misawa, Tomoyo; Miyashita, Mitsunori; Kawa, Masako; Abe, Koji; Abe, Mayumi; Nakayama, Yasuko; Given, Charles W

    2009-01-01

    The aim of this study was to validate the Caregiver Reaction Assessment (CRA) among caregivers of community-dwelling advanced cancer patients in Japan. A cross-sectional questionnaire was administered to advanced cancer patients and their caregivers who were cared for at day hospices and home palliative care services. We translated the CRA into Japanese, and then verified factor validity, reliability, construct validity, concurrent validity, and known groups' validity. To address construct and concurrent validity, we calculated Pearson's correlation coefficient between the Japanese version of the CRA and the Burden Index of Caregivers (BIC). To address known groups' validity, we used the t test or analysis of variance (ANOVA). A total of 57 caregivers participated in the study. Five factors were extracted (''impact on schedule,'' ''caregiver's self-esteem,'' ''lack of family support,'' ''impact on health,'' and ''impact on finances'') and reliability was good. Construct and concurrent validity among the subscales of the BIC were good. Regarding known groups validity, the subscale score of ''impact on schedule'' for the groups that cared 6 hours or more per day was higher than the other group (P = .04). The CRA-J is valid and reliable. This scale is useful for caregivers of cancer patients in Japan.

  8. Validity and reliability of the Brazilian version of Yale-Brown obsessive compulsive scale-shopping version (YBOCS-SV).

    Science.gov (United States)

    Leite, Priscilla Lourenço; Filomensky, Tatiana Zambrano; Black, Donald W; Silva, Adriana Cardoso

    2014-08-01

    The Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV) is considered the gold standard in the assessment of shopping severity. It is designed to assess cognitions and behaviors relating to compulsive buying behavior. The present study aims to assess the validity of the Brazilian version of this scale. For the study, composed the sample 610 participants: 588 subjects of a general population and 22 compulsive buyers. Factorial analysis was performed to assess the relations and the correlation between the YBOCS-SV, the Compulsive Buying Scale (CBS), and Richmond Compulsive Buying Scale (RCBS), was assessed using Pearson coefficient, for study of convergent and divergent validity. Cronbach's alpha coefficients were used to assess internal consistency. The results show good to excellent psychometric parameters for the YBOCS-SV in its Brazilian version. With regard to correlations, the YBOCS-SV is inversely and proportionally correlated with CBS and the RCBS, indicating that the YBOCS-SV is an excellent instrument for screening compulsive buying. The YBOCS-SV presented high alpha coefficient of Cronbach's alpha (0.92), demonstrating good reliability. The Brazilian version of the YBOCS-SV is indicated to diagnose compulsive buying disorder, and likely use for the purposes intended in the Brazilian population. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review.

    Science.gov (United States)

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-09-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. Copyright © 2014. Published by Elsevier B.V.

  10. Reliability and validity of the Spanish version of the modified Yale Preoperative Anxiety Scale.

    Science.gov (United States)

    Jerez, C; Ullán, A M; Lázaro, J J

    2016-01-01

    To minimise preoperative stress and increase child cooperation during induction of anaesthesia is one of the most important perioperative objectives. The modified Yale Preoperative Anxiety Scale was developed to evaluate anxiety. The aim of this study was to translate into Spanish, and validate the psychometric properties of the Spanish version of this scale. The Spanish translation of the scale was performed following the World Health Organisation guidelines. During induction of anaesthesia, 81 children aged 2 to 12 years were recorded. Two observers evaluated the recordings independently. Content validity index of modified Yale Preoperative Anxiety Scale Spanish version was assessed. Weighted Kappa was calculated to measure interobserver agreement, and the Pearson correlation between the Induction Compliance Checklist and the modified Yale Preoperative Anxiety Scale was determined. The Spanish version obtained high content validity (0.91 to 0.98). Reliability analysis using weighted Kappa statistics revealed that interobserver agreement ranged from 0.54 to 0.75. Concurrent validity was high (r=0.94; P<.001). Validated assessment tools are needed to evaluate interventions to reduce child preoperative anxiety. The Spanish version of the modified Yale Preoperative Anxiety Scale evaluated in this study has shown good psychometric properties of reliability and validity. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Support vector machine with a Pearson VII function kernel for discriminating halophilic and non-halophilic proteins.

    Science.gov (United States)

    Zhang, Guangya; Ge, Huihua

    2013-10-01

    Understanding of proteins adaptive to hypersaline environment and identifying them is a challenging task and would help to design stable proteins. Here, we have systematically analyzed the normalized amino acid compositions of 2121 halophilic and 2400 non-halophilic proteins. The results showed that halophilic protein contained more Asp at the expense of Lys, Ile, Cys and Met, fewer small and hydrophobic residues, and showed a large excess of acidic over basic amino acids. Then, we introduce a support vector machine method to discriminate the halophilic and non-halophilic proteins, by using a novel Pearson VII universal function based kernel. In the three validation check methods, it achieved an overall accuracy of 97.7%, 91.7% and 86.9% and outperformed other machine learning algorithms. We also address the influence of protein size on prediction accuracy and found the worse performance for small size proteins might be some significant residues (Cys and Lys) were missing in the proteins. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Reliability and validity of the Japanese version of the simplified nutritional appetite questionnaire in community-dwelling older adults.

    Science.gov (United States)

    Nakatsu, Nobuyuki; Sawa, Ryuichi; Misu, Shogo; Ueda, Yuya; Ono, Rei

    2015-12-01

    To translate the Simplified Nutritional Appetite Questionnaire (SNAQ) into Japanese, and assess its reliability and validity in Japanese community-dwelling older adults. A total of 84 community-dwelling older adults people aged 65 years or older were included in the present study, and those with a Mini-Mental State Examination score of validity was evaluated by measuring the Pearson's correlation coefficient between the SNAQ and Mini-Nutritional Assessment Short-Form scores, Geriatric Depression Scale scores, walking speed test, chair-stand test, hand grip strength test, or the Timed Up and Go test. The mean score of the Japanese version of the SNAQ was 15.5, with a Cronbach's alpha coefficient of 0.545 and intraclass correlation coefficient of 0.754. Factor analysis showed a single factor with 50.0% explained variance. The SNAQ was significantly associated with the Mini-Nutritional Assessment Short-Form, Geriatric Depression Scale, walking speed test, chair-stand test and the Timed Up and Go test. Handgrip strength test did not show a significant association with the SNAQ. The Japanese version of the SNAQ had sufficient reliability and validity. Furthermore, SNAQ (Japanese version) is useful for evaluating the appetite of community-dwelling older adults in Japan. Geriatr Gerontol Int 2015; 15: 1264-1269. © 2014 Japan Geriatrics Society.

  13. The test-retest reliability and criterion validity of a high-intensity, netball-specific circuit test: The Net-Test.

    Science.gov (United States)

    Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T

    2018-04-12

    To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Development and validity of a scale of perception of velocity in resistance exercise.

    Science.gov (United States)

    Bautista, Iker J; Chirosa, Ignacio J; Chirosa, Luis J; Martín, Ignacio; González, Andrés; Robertson, Robert J

    2014-09-01

    This aims of this study were twofold; 1) to development a new scale of perceived velocity in the bench press exercise and 2) to examine the scales concurrent validity. Twenty one physically active males with mean ±SD age, height and weights of: 27.5 ± 4.7 years, 1.77 ± 0.07 m, and 79.8 ± 10.3 kg respectively, took part in the study. The criterion variable used to test the validity of the new scale was the mean execution velocity (Velreal) of the bench press exercise. Three intensities (light loads [ 70% 1RM]) were measured randomly during 5 days of testing. Perceived velocity (Velscale) was measured immediately after each exercise set using the new scale. A positive linear correlation (r range = 0.69 to 0.81) was found in all three intensities, analyzed individually, between the Velreal and Velscale. Pearson correlations showed a greater frequency of scale use resulted higher correlation values (range r = 0.88 to 0.96). This study provides evidence of the concurrent validity of a new scale of perceived velocity in the bench press exercise in trained adult males. These results suggest the exercise intensity of the bench press can be quantified quickly and effective using this new scale of perceived velocity, particularly when training for maximum power. Key PointsMeasurement of perception of velocity can complement other scales of perception such as the 15 category Borg scale or the OMNI-RES.The results obtained in this study show that there was a positive correlation between the perceived velocity measured by the scale and actual velocityRegular use of the new scale of perceived velocity in external resistance training provides athletes with continuous feedback of execution velocity in each repetition and set, especially with high power loads.

  15. Ten Years Trend Analysis of Malaria Prevalence and its Correlation ...

    African Journals Online (AJOL)

    The data were analyzed using SPSS software package 16.0. Pearson's correlation analysis was conducted to see the correlation between plasmodium species and climatic variables. Within the last decade (2004–2013) a total of 30,070 blood films were examined for malaria in Sire health center and of this 6036 (20.07%) ...

  16. Development and validation of a food frequency questionnaire for consumption of polyphenol-rich foods in pregnant women.

    Science.gov (United States)

    Vian, Izabele; Zielinsky, Paulo; Zilio, Ana Maria; Mello, Anne; Lazzeri, Bruna; Oliveira, Andressa; Lampert, Kenya Venusa; Piccoli, Antônio; Nicoloso, Luis Henrique; Bubols, Guilherme Borges; Garcia, Solange Cristina

    2015-10-01

    Previous studies have shown that maternal consumption of polyphenol-rich foods after the third trimester of pregnancy may interfere with the anatomical and functional activity of the fetal heart as, to our knowledge, there are no validated instruments to quantify total polyphenols in pregnant women. The aim of this study was evaluate the reproducibility and validity of a food frequency questionnaire (FFQ), with 52 items, to assess the intake of polyphenol-rich foods in pregnant women in Brazil. This cross-sectional study included 120 pregnant women who participated in nutritional interviews in two moments. The intake of polyphenols estimated by the developed FFQ was compared with the average of two 24-h recalls (24HR), with the average intake measured by a 3-day food diary (D3days) and with the urinary excretion of total polyphenols. The triangular method was applied to calculate Pearson's correlation coefficients, intraclass correlation and Bland-Altman plots for the FFQ, using an independent biochemical marker, in addition to classification by quarters of consumption. The questionnaires were log transformed, adjusted for body mass index and gestational age. The adjustment for energy was applied only of 24HR and D3days. Analysis of the reproducibility between the FFQ showed a very high correlation (r = 0.72; P questionnaire showed reproducibility and validity for the quantification of consumption of total polyphenols in pregnant women. © 2013 John Wiley & Sons Ltd.

  17. Evaluation of physicians' professional performance: An iterative development and validation study of multisource feedback instruments

    Directory of Open Access Journals (Sweden)

    Overeem Karlijn

    2012-03-01

    Full Text Available Abstract Background There is a global need to assess physicians' professional performance in actual clinical practice. Valid and reliable instruments are necessary to support these efforts. This study focuses on the reliability and validity, the influences of some sociodemographic biasing factors, associations between self and other evaluations, and the number of evaluations needed for reliable assessment of a physician based on the three instruments used for the multisource assessment of physicians' professional performance in the Netherlands. Methods This observational validation study of three instruments underlying multisource feedback (MSF was set in 26 non-academic hospitals in the Netherlands. In total, 146 hospital-based physicians took part in the study. Each physician's professional performance was assessed by peers (physician colleagues, co-workers (including nurses, secretary assistants and other healthcare professionals and patients. Physicians also completed a self-evaluation. Ratings of 864 peers, 894 co-workers and 1960 patients on MSF were available. We used principal components analysis and methods of classical test theory to evaluate the factor structure, reliability and validity of instruments. We used Pearson's correlation coefficient and linear mixed models to address other objectives. Results The peer, co-worker and patient instruments respectively had six factors, three factors and one factor with high internal consistencies (Cronbach's alpha 0.95 - 0.96. It appeared that only 2 percent of variance in the mean ratings could be attributed to biasing factors. Self-ratings were not correlated with peer, co-worker or patient ratings. However, ratings of peers, co-workers and patients were correlated. Five peer evaluations, five co-worker evaluations and 11 patient evaluations are required to achieve reliable results (reliability coefficient ≥ 0.70. Conclusions The study demonstrated that the three MSF instruments produced

  18. Development and Validation of the Survey of Organizational Research Climate (SORC)

    Science.gov (United States)

    Martinson, Brian C.; Thrush, Carol R.; Crain, A. Lauren

    2012-01-01

    Background Development and targeting efforts by academic organizations to effectively promote research integrity can be enhanced if they are able to collect reliable data to benchmark baseline conditions, to assess areas needing improvement, and to subsequently assess the impact of specific initiatives. To date, no standardized and validated tool has existed to serve this need. Methods A web- and mail-based survey was administered in the second half of 2009 to 2,837 randomly selected biomedical and social science faculty and postdoctoral fellows at 40 academic health centers in top-tier research universities in the United States. Measures included the Survey of Organizational Research Climate (SORC) as well as measures of perceptions of organizational justice. Results Exploratory and confirmatory factor analyses yielded seven subscales of organizational research climate, all of which demonstrated acceptable internal consistency (Cronbach’s α ranging from 0.81 to 0.87) and adequate test-retest reliability (Pearson r ranging from 0.72 to 0.83). A broad range of correlations between the seven subscales and five measures of organizational justice (unadjusted regression coefficients ranging from .13 to .95) document both construct and discriminant validity of the instrument. Conclusions The SORC demonstrates good internal (alpha) and external reliability (test-retest) as well as both construct and discriminant validity. PMID:23096775

  19. Development and validation of the Survey of Organizational Research Climate (SORC).

    Science.gov (United States)

    Martinson, Brian C; Thrush, Carol R; Lauren Crain, A

    2013-09-01

    Development and targeting efforts by academic organizations to effectively promote research integrity can be enhanced if they are able to collect reliable data to benchmark baseline conditions, to assess areas needing improvement, and to subsequently assess the impact of specific initiatives. To date, no standardized and validated tool has existed to serve this need. A web- and mail-based survey was administered in the second half of 2009 to 2,837 randomly selected biomedical and social science faculty and postdoctoral fellows at 40 academic health centers in top-tier research universities in the United States. Measures included the Survey of Organizational Research Climate (SORC) as well as measures of perceptions of organizational justice. Exploratory and confirmatory factor analyses yielded seven subscales of organizational research climate, all of which demonstrated acceptable internal consistency (Cronbach's α ranging from 0.81 to 0.87) and adequate test-retest reliability (Pearson r ranging from 0.72 to 0.83). A broad range of correlations between the seven subscales and five measures of organizational justice (unadjusted regression coefficients ranging from 0.13 to 0.95) document both construct and discriminant validity of the instrument. The SORC demonstrates good internal (alpha) and external reliability (test-retest) as well as both construct and discriminant validity.

  20. Validation of the Balance Board for Clinical Evaluation of Balance During Serious Gaming Rehabilitation Exercises.

    Science.gov (United States)

    Bonnechère, Bruno; Jansen, Bart; Omelina, Lubos; Sholukha, Victor; Van Sint Jan, Serge

    2016-09-01

    Balance and posture can be affected in various conditions or become decreased with aging. A diminution of balance control induces an increase of fall's risk. The Nintendo Wii Balance Board™ (WBB) is used in rehabilitation to perform balance exercises (using commercial video games). The WBB has also been validated to assess balance and posture in static conditions. However, there is currently no study investigating the use of WBB to assess balance during the realization of balance exercises using this device. The aim of this study was to validate the use of WBB, coupled with specially developed serious games, to assess dynamic balance during rehabilitation exercises. Thirty five subjects participated in this study. Subjects were asked to play two specially developed serious games. Center of pressure (CP) displacements were simultaneously recorded with a WBB and a gold standard force plate (FP). Nine parameters were derived from CP displacement. Bland and Altman plots, paired-sample t tests, intraclass correlation coefficient's, and Pearson's coefficient correlations were computed. Excellent correlation between both devices was found for each parameter for the two games (R = 0.95 and 0.96). Unlike previous work on the WBB, these excellent results were obtained without using any calibration procedure. Despite this, results were highly correlated between the WBB and the FP. The WBB could be used in clinics to assess balance during rehabilitation exercises and, thus, allows a more regular patient follow-up.

  1. Development and Validation of the Spanish Numeracy Understanding in Medicine Instrument.

    Science.gov (United States)

    Jacobs, Elizabeth A; Walker, Cindy M; Miller, Tamara; Fletcher, Kathlyn E; Ganschow, Pamela S; Imbert, Diana; O'Connell, Maria; Neuner, Joan M; Schapira, Marilyn M

    2016-11-01

    The Spanish-speaking population in the U.S. is large and growing and is known to have lower health literacy than the English-speaking population. Less is known about the health numeracy of this population due to a lack of health numeracy measures in Spanish. we aimed to develop and validate a short and easy to use measure of health numeracy for Spanish-speaking adults: the Spanish Numeracy Understanding in Medicine Instrument (Spanish-NUMi). Items were generated based on qualitative studies in English- and Spanish-speaking adults and translated into Spanish using a group translation and consensus process. Candidate items for the Spanish NUMi were selected from an eight-item validated English Short NUMi. Differential Item Functioning (DIF) was conducted to evaluate equivalence between English and Spanish items. Cronbach's alpha was computed as a measure of reliability and a Pearson's correlation was used to evaluate the association between test scores and the Spanish Test of Functional Health Literacy (S-TOFHLA) and education level. Two-hundred and thirty-two Spanish-speaking Chicago residents were included in the study. The study population was diverse in age, gender, and level of education and 70 % reported Mexico as their country of origin. Two items of the English eight-item Short NUMi demonstrated DIF and were dropped. The resulting six-item test had a Cronbach's alpha of 0.72, a range of difficulty using classical test statistics (percent correct: 0.48 to 0.86), and adequate discrimination (item-total score correlation: 0.34-0.49). Scores were positively correlated with print literacy as measured by the S- TOFHLA (r = 0.67; p Spanish NUMi is a reliable and valid measure of important numerical concepts used in communicating health information.

  2. Relative Validity and Reliability of a 1-Week, Semiquantitative Food Frequency Questionnaire for Women Participating in the Supplemental Nutrition Assistance Program.

    Science.gov (United States)

    Sanjeevi, Namrata; Freeland-Graves, Jeanne; George, Goldy Chacko

    2017-12-01

    The Supplemental Nutrition Assistance Program (SNAP) plays a critical role in reducing food insecurity by distribution of benefits at a monthly interval to participants. Households that receive assistance from SNAP spend at least three-quarters of benefits within the first 2 weeks of receipt. Because this expenditure pattern may be associated with lower food intake toward the end of the month, it is important to develop a tool that can assess the weekly diets of SNAP participants. The goal of this study was to develop and assess the relative validity and reliability of a semiquantitative 1-week food frequency questionnaire (FFQ) tailored to a population of women participating in SNAP. The FFQ was derived from an existing 195-item FFQ that was based on a reference period of 1 month. This 195-item FFQ has been validated in a population of low-income postpartum women who were recruited from central Texas during 2004. Mean daily servings of each food item in the 195-item FFQ completed by women who took part in the 2004 validation study were calculated to determine the most frequently consumed food items. Emphasis on these items led to the creation of a shorter, 1-week FFQ of only 95 items. This new 1-week instrument was compared with 3-day diet records to evaluate relative validity in a sample of women participating in SNAP. For reliability, the FFQ was administered a second time, separated by a 1-month time interval. The validity study included 70 female SNAP participants who were recruited from the partner agencies of the Central Texas Food Bank from March to June 2015. A subsample of 40 women participated in the reliability study. Outcome measures were mean nutrient intake values obtained from the two tests of the 95-item FFQ and 3-day diet records. Deattenuated Pearson correlation coefficients examined relationships in nutrient intake between the 95-item FFQ and 3-day diet records, and a paired samples t test determined differences in mean nutrient intake. Weighted

  3. Saving time and money: a validation of the self ratings on the prospective NIMH Life-Chart Method (NIMH-LCM).

    Science.gov (United States)

    Born, Christoph; Amann, Benedikt L; Grunze, Heinz; Post, Robert M; Schärer, Lars

    2014-05-07

    Careful observation of the longitudinal course of bipolar disorders is pivotal to finding optimal treatments and improving outcome. A useful tool is the daily prospective Life-Chart Method, developed by the National Institute of Mental Health. However, it remains unclear whether the patient version is as valid as the clinician version. We compared the patient-rated version of the Lifechart (LC-self) with the Young-Mania-Rating Scale (YMRS), Inventory of Depressive Symptoms-Clinician version (IDS-C), and Clinical Global Impression-Bipolar version (CGI-BP) in 108 bipolar I and II patients who participated in the Naturalistic Follow-up Study (NFS) of the German centres of the Bipolar Collaborative Network (BCN; formerly Stanley Foundation Bipolar Network). For statistical evaluation, levels of severity of mood states on the Lifechart were transformed numerically and comparison with affective scales was performed using chi-square and t tests. For testing correlations Pearson´s coefficient was calculated. Ratings for depression of LC-self and total scores of IDS-C were found to be highly correlated (Pearson coefficient r = -.718; p money saving alternative to the clinician-rated version which should be incorporated in future clinical research in bipolar disorder. Generalizability of the results is limited by the selection of highly motivated patients in specialized bipolar centres and by the open design of the study.

  4. Development and Validation of an Abbreviated Questionnaire to Easily Measure Cognitive Failure in ICU Survivors: A Multicenter Study.

    Science.gov (United States)

    Wassenaar, Annelies; de Reus, Jorn; Donders, A Rogier T; Schoonhoven, Lisette; Cremer, Olaf L; de Lange, Dylan W; van Dijk, Diederik; Slooter, Arjen J C; Pickkers, Peter; van den Boogaard, Mark

    2018-01-01

    To develop and validate an abbreviated version of the Cognitive Failure Questionnaire that can be used by patients as part of self-assessment to measure functional cognitive outcome in ICU survivors. A retrospective multicenter observational study. The ICUs of two Dutch university hospitals. Adult ICU survivors. None. Cognitive functioning was evaluated between 12 and 24 months after ICU discharge using the full 25-item Cognitive Failure Questionnaire (CFQ-25). Incomplete CFQ-25 questionnaires were excluded from analysis. Forward selection in a linear regression model was used in hospital A to assess which of the CFQ-25 items should be included to prevent a significant loss of correlation between an abbreviated and the full CFQ-25. Subsequently, the performance of an abbreviated Cognitive Failure Questionnaire was determined in hospital B using Pearson's correlation. A Bland-Altman plot was used to examine whether the reduced-item outcome scores of an abbreviated Cognitive Failure Questionnaire were a replacement for the full CFQ-25 outcome scores. Among 1,934 ICU survivors, 1,737 were included, 819 in hospital A, 918 in hospital B. The Pearson's correlation between the abbreviated 14-item Cognitive Failure Questionnaire (CFQ-14) and the CFQ-25 was 0.99. The mean of the difference scores was -0.26, and 95% of the difference scores fell within +5 and -5.5 on a 100-point maximum score. It is feasible to use the abbreviated CFQ-14 to measure self-reported cognitive failure in ICU survivors as this questionnaire has a similar performance as the full CFQ-25.

  5. A Study of Correlation of Various Growth Indicators with Chronological Age.

    Science.gov (United States)

    Singh, Sarabjeet; Sandhu, Navreet; Puri, Taruna; Gulati, Ritika; Kashyap, Rita

    2015-01-01

    The aim of this study was to assess the relationship of chronological age with cervical vertebrae skeletal maturation, frontal sinus width and antegonial notch depth and a correlation, if any, among the three variables. The samples were derived from lateral cephalometric radiographs of 80 subjects (40 males, 40 females; age range: 10 to 19 years). Cervical vertebral development was evaluated by the method of Hassel and Farman, frontal sinus width was measured by the method described by Ertürk and antegonial notch depth as described by Singer et al. The Pearson's correlation coefficients were estimated to assess the relationship of chronological age with cervical vertebrae skeletal maturation, frontal sinus width and antegonial notch depth. The Pearson's correlation coefficient were 0.855 (p correlation was found between chronological age and cervical vertebrae skeletal maturation, and between chronological age and frontal sinus width. Nonsignificant correlation was found between chronological age and antegonial notch depth. How to cite this article: Singh S, Sandhu N, Puri T, Gulati R, Kashyap R. A Study of Correlation of Various Growth Indicators with Chronological Age. Int J Clin Pediatr Dent 2015;8(3): 190-195.

  6. Validity and Reliability of the Clinical Competency Evaluation Instrument for Use among Physiotherapy Students: Pilot study.

    Science.gov (United States)

    Muhamad, Zailani; Ramli, Ayiesah; Amat, Salleh

    2015-05-01

    The aim of this study was to determine the content validity, internal consistency, test-retest reliability and inter-rater reliability of the Clinical Competency Evaluation Instrument (CCEVI) in assessing the clinical performance of physiotherapy students. This study was carried out between June and September 2013 at University Kebangsaan Malaysia (UKM), Kuala Lumpur, Malaysia. A panel of 10 experts were identified to establish content validity by evaluating and rating each of the items used in the CCEVI with regards to their relevance in measuring students' clinical competency. A total of 50 UKM undergraduate physiotherapy students were assessed throughout their clinical placement to determine the construct validity of these items. The instrument's reliability was determined through a cross-sectional study involving a clinical performance assessment of 14 final-year undergraduate physiotherapy students. The content validity index of the entire CCEVI was 0.91, while the proportion of agreement on the content validity indices ranged from 0.83-1.00. The CCEVI construct validity was established with factor loading of ≥0.6, while internal consistency (Cronbach's alpha) overall was 0.97. Test-retest reliability of the CCEVI was confirmed with a Pearson's correlation range of 0.91-0.97 and an intraclass coefficient correlation range of 0.95-0.98. Inter-rater reliability of the CCEVI domains ranged from 0.59 to 0.97 on initial and subsequent assessments. This pilot study confirmed the content validity of the CCEVI. It showed high internal consistency, thereby providing evidence that the CCEVI has moderate to excellent inter-rater reliability. However, additional refinement in the wording of the CCEVI items, particularly in the domains of safety and documentation, is recommended to further improve the validity and reliability of the instrument.

  7. Evaluating validity and reliability of Persian version of Supports Intensity Scale in adults with intellectual disability

    Directory of Open Access Journals (Sweden)

    Shahin Soltani

    2013-12-01

    Full Text Available Background: Shifting paradigms regarding the ways to assess the support needs of people with intellectual disability in 1980 necessitates the design and development of appropriate tools more than ever. In this regard, American Association on Intellectual and Developmental Disabilities (AAIDD developed Supports Intensity Scale (SIS to respond the lack of an appropriate measurement tool. The aim of this study is the cultural adaptation and evaluation of psychometric properties of Supports Intensity Scale in adults with intellectual disability. Methods: Validity of Persian version of SIS was assessed by Content validity. The reliability of the scale was evaluated using Cronbach's alpha and test–retest reliability with a 3-week interval. In this study, the sample contained 43 adults (29 men and 14 women with intellectual disability. Results: The content of the Persian version of SIS was approved by the experts. The Cronbach's alpha reliability coefficients for the subscales ranged between 0.80 and 0.99. Also, Intraclass correlation coefficients ranged between 0.90 and 0.99 (P<0.001. Furthermore, all Pearson correlation coefficients among the SIS subscales ranged between 0.63 and 0.98 (P<0.01. Conclusion: The results of this study indicated that the validity and reliability of the equivalent Persian version of SIS for identifying pattern and required supports intensity in adults with intellectual disability is acceptable.

  8. Relative validity of a food frequency questionnaire to assess nutrient intake in pregnant women.

    Science.gov (United States)

    McGowan, C A; Curran, S; McAuliffe, F M

    2014-04-01

    To date, there are no food frequency questionnaires that have been validated to assess nutrient intakes in pregnant women in Ireland. The present study aimed to assess the relative validity of a self-administered food frequency questionnaire during pregnancy. The food frequency questionnaire was administered once during pregnancy between 12 and 34 weeks. Participants also completed a 3-day food diary during each trimester of pregnancy (reference method) and intakes from both the food frequency questionnaire and the mean of the 3-day food diaries were compared in a sample of 130 participants from the control arm of an intervention study. Energy-adjusted Pearson's correlation coefficients ranged from 0.24 (riboflavin) to 0.59 (magnesium) and were all statistically significant (P food frequency questionnaire tended to report higher energy and nutrient intakes compared to the food diaries. On average, 74% of participants were classified into the same ± 1 quartile and 7% into opposing quartiles by the two methods. Overall, our food frequency questionnaire showed good relative validity. We conclude that a single administration of a food frequency questionnaire is a valid tool for ranking women in accordance with their nutrient intakes during pregnancy. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  9. Validity of a food frequency questionnaire in a population with high alcohol consumption in Japan.

    Science.gov (United States)

    Nakahata, Noriko Tsunematsu; Takada, Akihiko Nakamura; Imaeda, Nahomi; Goto, Chiho; Kuwabara, Kazuyo Hirasada; Niimura, Hideshi; Arai, Yusuke; Yoshita, Katsushi; Takezaki, Toshiro

    2016-01-01

    Alcohol consumption has a relatively large impact on energy intake in drinkers, and several studies reported different dietary habits from non-drinkers. However, few studies have investigated the influence of alcohol consumption on the validity of the Food Frequency Questionnaire (FFQ). To investigate its influence, we conducted a validity test in a population with high alcohol consumption. The study subjects were 66 residents living on an island in the south-western part of Japan. We conducted the FFQ and 12-day-weighed dietary records (12d-WDRs) in each 3 day of each 4 season. We calculated Pearson correlation coefficients (CCs) and agreement rates according to quartile classification after adjusting for energy. The intake energy (kcal) estimated from 12d-WDRs and FFQ was 1,641 and 1,534 in women, and 2,093 and 1,979 in men, respectively. The cumulative percentage contribution of the alcohol energy was 6.7% in men. De-attenuated, log-transformed Pearson's median CCs between the nutrients quantified with the 12d-WDRs and FFQ were 0.51 in women and 0.38 in men. The CCs for carbohydrate and saturated fatty acids intake of men were lower than those in the previous Tokai study using the same FFQ. The findings in agreement rates were consistent with the Tokai study. This study suggested that the FFQ can be used for epidemiological studies using categorical comparisons in this population, although the underestimation of carbohydrates and other nutrients in the FFQ should be taken into consideration.

  10. Assessing validity of a short food frequency questionnaire on present dietary intake of elderly Icelanders

    Directory of Open Access Journals (Sweden)

    Eysteinsdottir Tinna

    2012-03-01

    Full Text Available Abstract Background Few studies exist on the validity of food frequency questionnaires (FFQs administered to elderly people. The aim of this study was to assess the validity of a short FFQ on present dietary intake, developed specially for the AGES-Reykjavik Study, which includes 5,764 elderly individuals. Assessing the validity of FFQs is essential before they are used in studies on diet-related disease risk and health outcomes. Method 128 healthy elderly participants (74 y ± 5.7; 58.6% female answered the AGES-FFQ, and subsequently filled out a 3-day weighed food record. Validity of the AGES-FFQ was assessed by comparing its answers to the dietary data obtained from the weighed food records, using Spearman's rank correlation, Chi-Square/Kendall's tau, and a Jonckheere-Terpstra test for trend. Result For men a correlation ≥ 0.4 was found for potatoes, fresh fruits, oatmeal/muesli, cakes/cookies, candy, dairy products, milk, pure fruit juice, cod liver oil, coffee, tea and sugar in coffee/tea (r = 0.40-0.71. A lower, but acceptable, correlation was also found for raw vegetables (r = 0.33. The highest correlation for women was found for consumption of rye bread, oatmeal/muesli, raw vegetables, candy, dairy products, milk, pure fruit juice, cod liver oil, coffee and tea (r = 0.40-0.61. An acceptable correlation was also found for fish topping/salad, fresh fruit, blood/liver sausage, whole-wheat bread, and sugar in coffee/tea (r = 0.28-0.37. Questions on meat/fish meals, cooked vegetables and soft drinks did not show a significant correlation to the reference method. Pearson Chi-Square and Kendall's tau showed similar results, as did the Jonckheere-Terpstra trend test. Conclusion A majority of the questions in the AGES-FFQ had an acceptable correlation and may be used to rank individuals according to their level of intake of several important foods/food groups. The AGES-FFQ on present diet may therefore be used to study the relationship between

  11. Assessing validity of a short food frequency questionnaire on present dietary intake of elderly Icelanders

    Science.gov (United States)

    2012-01-01

    Background Few studies exist on the validity of food frequency questionnaires (FFQs) administered to elderly people. The aim of this study was to assess the validity of a short FFQ on present dietary intake, developed specially for the AGES-Reykjavik Study, which includes 5,764 elderly individuals. Assessing the validity of FFQs is essential before they are used in studies on diet-related disease risk and health outcomes. Method 128 healthy elderly participants (74 y ± 5.7; 58.6% female) answered the AGES-FFQ, and subsequently filled out a 3-day weighed food record. Validity of the AGES-FFQ was assessed by comparing its answers to the dietary data obtained from the weighed food records, using Spearman's rank correlation, Chi-Square/Kendall's tau, and a Jonckheere-Terpstra test for trend. Result For men a correlation ≥ 0.4 was found for potatoes, fresh fruits, oatmeal/muesli, cakes/cookies, candy, dairy products, milk, pure fruit juice, cod liver oil, coffee, tea and sugar in coffee/tea (r = 0.40-0.71). A lower, but acceptable, correlation was also found for raw vegetables (r = 0.33). The highest correlation for women was found for consumption of rye bread, oatmeal/muesli, raw vegetables, candy, dairy products, milk, pure fruit juice, cod liver oil, coffee and tea (r = 0.40-0.61). An acceptable correlation was also found for fish topping/salad, fresh fruit, blood/liver sausage, whole-wheat bread, and sugar in coffee/tea (r = 0.28-0.37). Questions on meat/fish meals, cooked vegetables and soft drinks did not show a significant correlation to the reference method. Pearson Chi-Square and Kendall's tau showed similar results, as did the Jonckheere-Terpstra trend test. Conclusion A majority of the questions in the AGES-FFQ had an acceptable correlation and may be used to rank individuals according to their level of intake of several important foods/food groups. The AGES-FFQ on present diet may therefore be used to study the relationship between consumption of several

  12. Development of a French-Canadian version of the Oswestry Disability Index: cross-cultural adaptation and validation.

    Science.gov (United States)

    Denis, Isabelle; Fortin, Luc

    2012-04-01

    Cross-cultural translation and psychometric testing. To translate, culturally adapt, and validate the Oswestry Disability Index (ODI) version 2.0 for the French-Canadian population. Many authors have recommended the administration of standardized instruments, rather than the creation of new scales, and advocate the adaptation of validated questionnaires in other languages. The application of these scales in different countries and by cultural groups necessitates cross-cultural adaptation. Many scales evaluate the functional incapacity resulting from low back pain. The ODI is among the most commonly used for this purpose. The French-Canadian ODI (ODI-FC) was developed by cross-cultural adaptation following internationally recommended methodology: forward translation, back translation, expert committee revision, and clinical evaluation of the prefinal version. Psychometric testing was performed on 72 patients with chronic low back pain. The subjects were recruited from a physiatry department in a university hospital and from a private practice physiatry clinic. They came from the Montreal area. The psychometric testing included internal consistency (Cronbach α), test-retest reliability (intraclass correlation coefficient) with a time interval set at 48 hours, and construct validity, comparing the ODI-FC with the Roland-Morris Disability Questionnaire and the Quebec Back Pain Disability Scale (Pearson correlation coefficient). In 44.4% of the subjects, the average duration of low-back pain varied between 1 and 5 years. Average score for the ODI-FC was 29.2. Good internal consistency was found (Cronbach α = 0.88). Reliability was excellent, with intraclass correlation coefficient = 0.92 (95% confidence interval, 0.87-0.95). Construct validity results revealed excellent correlations between the ODI and the Quebec Back Pain Disability Scale (r = 0.90) and between the ODI and the Roland-Morris Disability Questionnaire (r = 0.84). Cross-cultural translation and

  13. Reliability and validity of a Chinese version of the Diagnostic Interview for Borderlines-Revised.

    Science.gov (United States)

    Wang, Lanlan; Yuan, Chenmei; Qiu, Jianying; Gunderson, John; Zhang, Min; Jiang, Kaida; Leung, Freedom; Zhong, Jie; Xiao, Zeping

    2014-09-01

    Borderline personality disorder (BPD) is the most studied of the axis II disorders. One of the most widely used diagnostic instruments is the Diagnostic Interview for Borderline Patients-Revised (DIB-R). The aim of this study was to test the reliability and validity of DIB-R for use in the Chinese culture. The reliability and validity of the DIB-R Chinese version were assessed in a sample of 236 outpatients with a probable BPD diagnosis. The Structured Clinical Interview for DSM-IV Personality Disorders (SCID-II) was used as a standard. Test-retest reliability was tested six months later with 20 patients, and inter-rater reliability was tested on 32 patients. The Chinese version of the DIB-R showed good internal global consistency (Cronbach's α of 0.916), good test-retest reliability (Pearson correlation of 0.704), good inter-rater reliability (intra-class correlation coefficient of 0.892 and kappa of 0.861). When compared with the DSM-IV diagnosis as measured by the SCID-II, the DIB-R showed relatively good sensitivity (0.768) and specificity (0.891) at the cutoff of 7, moderate diagnostic convergence (kappa of 0.631), as well as good discriminating validity. The Chinese version of the DIB-R has good psychometric properties, which renders it a valuable method for examining the presence, the severity, and component phenotypes of BPD in Chinese samples. © 2013 Wiley Publishing Asia Pty Ltd.

  14. The validity and reliability of script concordance test in otolaryngology residency training.

    Science.gov (United States)

    Iravani, Kamyar; Amini, Mitra; Doostkam, Aida; Dehbozorgian, Mahnaz

    2016-04-01

    The script concordance test (SCT) is one the best tools used to evaluate clinical reasoning in ill-defined clinical situations. The aim of this study was to demonstrate SCT application in otolaryngology residency training. A 20 item otolaryngology SCT containing 60 questions was administered to 26 otolaryngology residents. The test was prepared by two otolaryngologists familiar to medical education. These questions have been validated by otolaryngology experts. The panel consisted of 9 academic staff in the field of otolaryngology. Pearson correlation test was used to assess the reliability of the test. The obtained mean scores were 68.4±5.8 (out of 100) for residents and 78.2±6.4(out of 100) for experts. There was a significant difference between the two scores (preliable tool to evaluate clinical reasoning in otolaryngology residents. It should be included in otolaryngology residency training.

  15. Validation of an instrument to assess toddler feeding practices of Latino mothers.

    Science.gov (United States)

    Chaidez, Virginia; Kaiser, Lucia L

    2011-08-01

    This paper describes qualitative and quantitative aspects of testing a 34-item Toddler-Feeding Questionnaire (TFQ), designed for use in Latino families, and the associations between feeding practices and toddler dietary outcomes. Qualitative methods included review by an expert panel for content validity and cognitive testing of the tool to assess face validity. Quantitative analyses included use of exploratory factor analysis for construct validity; Pearson's correlations for test-retest reliability; Cronbach's alpha (α) for internal reliability; and multivariate regression for investigating relationships between feeding practices and toddler diet and anthropometry. Interviews were conducted using a convenience sample of 94 Latino mother and toddler dyads obtained largely through the Supplemental Nutrition Program for Women, Infants and Children (WIC). Data collection included household characteristics, self-reported early-infant feeding practices, the toddler's dietary intake, and anthropometric measurements. Factor analysis suggests the TFQ contains three subscales: indulgent; authoritative; and environmental influences. The TFQ demonstrated acceptable reliability for most measures. As hypothesized, indulgent practices in Latino toddlers were associated with increased energy consumption and higher intakes of total fat, saturated fat, and sweetened beverages. This tool may be useful in future research exploring the relationship of toddler feeding practices to nutritional outcomes in Latino families. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Comparison between uroflowmetry and sonouroflowmetry in recording of urinary flow in healthy men.

    Science.gov (United States)

    Krhut, Jan; Gärtner, Marcel; Sýkora, Radek; Hurtík, Petr; Burda, Michal; Luňáček, Libor; Zvarová, Katarína; Zvara, Peter

    2015-08-01

    To evaluate the accuracy of sonouroflowmetry in recording urinary flow parameters and voided volume. A total of 25 healthy male volunteers (age 18-63 years) were included in the study. All participants were asked to carry out uroflowmetry synchronous with recording of the sound generated by the urine stream hitting the water level in the urine collection receptacle, using a dedicated cell phone. From 188 recordings, 34 were excluded, because of voided volume Pearson's correlation coefficient was used to compare parameters recorded by uroflowmetry with those calculated based on sonouroflowmetry recordings. The flow pattern recorded by sonouroflowmetry showed a good correlation with the uroflowmetry trace. A strong correlation (Pearson's correlation coefficient 0.87) was documented between uroflowmetry-recorded flow time and duration of the sound signal recorded with sonouroflowmetry. A moderate correlation was observed in voided volume (Pearson's correlation coefficient 0.68) and average flow rate (Pearson's correlation coefficient 0.57). A weak correlation (Pearson's correlation coefficient 0.38) between maximum flow rate recorded using uroflowmetry and sonouroflowmetry-recorded peak sound intensity was documented. The present study shows that the basic concept utilizing sound analysis for estimation of urinary flow parameters and voided volume is valid. However, further development of this technology and standardization of recording algorithm are required. © 2015 The Japanese Urological Association.

  17. Calibration and Validation of the Dutch-Flemish PROMIS Pain Interference Item Bank in Patients with Chronic Pain.

    Science.gov (United States)

    Crins, Martine H P; Roorda, Leo D; Smits, Niels; de Vet, Henrica C W; Westhovens, Rene; Cella, David; Cook, Karon F; Revicki, Dennis; van Leeuwen, Jaap; Boers, Maarten; Dekker, Joost; Terwee, Caroline B

    2015-01-01

    The Dutch-Flemish PROMIS Group translated the adult PROMIS Pain Interference item bank into Dutch-Flemish. The aims of the current study were to calibrate the parameters of these items using an item response theory (IRT) model, to evaluate the cross-cultural validity of the Dutch-Flemish translations compared to the original English items, and to evaluate their reliability and construct validity. The 40 items in the bank were completed by 1085 Dutch chronic pain patients. Before calibrating the items, IRT model assumptions were evaluated using confirmatory factor analysis (CFA). Items were calibrated using the graded response model (GRM), an IRT model appropriate for items with more than two response options. To evaluate cross-cultural validity, differential item functioning (DIF) for language (Dutch vs. English) was examined. Reliability was evaluated based on standard errors and Cronbach's alpha. To evaluate construct validity correlations with scores on legacy instruments (e.g., the Disabilities of the Arm, Shoulder and Hand Questionnaire) were calculated. Unidimensionality of the Dutch-Flemish PROMIS Pain Interference item bank was supported by CFA tests of model fit (CFI = 0.986, TLI = 0.986). Furthermore, the data fit the GRM and showed good coverage across the pain interference continuum (threshold-parameters range: -3.04 to 3.44). The Dutch-Flemish PROMIS Pain Interference item bank has good cross-cultural validity (only two out of 40 items showing DIF), good reliability (Cronbach's alpha = 0.98), and good construct validity (Pearson correlations between 0.62 and 0.75). A computer adaptive test (CAT) and Dutch-Flemish PROMIS short forms of the Dutch-Flemish PROMIS Pain Interference item bank can now be developed.

  18. Calibration and Validation of the Dutch-Flemish PROMIS Pain Interference Item Bank in Patients with Chronic Pain.

    Directory of Open Access Journals (Sweden)

    Martine H P Crins

    Full Text Available The Dutch-Flemish PROMIS Group translated the adult PROMIS Pain Interference item bank into Dutch-Flemish. The aims of the current study were to calibrate the parameters of these items using an item response theory (IRT model, to evaluate the cross-cultural validity of the Dutch-Flemish translations compared to the original English items, and to evaluate their reliability and construct validity. The 40 items in the bank were completed by 1085 Dutch chronic pain patients. Before calibrating the items, IRT model assumptions were evaluated using confirmatory factor analysis (CFA. Items were calibrated using the graded response model (GRM, an IRT model appropriate for items with more than two response options. To evaluate cross-cultural validity, differential item functioning (DIF for language (Dutch vs. English was examined. Reliability was evaluated based on standard errors and Cronbach's alpha. To evaluate construct validity correlations with scores on legacy instruments (e.g., the Disabilities of the Arm, Shoulder and Hand Questionnaire were calculated. Unidimensionality of the Dutch-Flemish PROMIS Pain Interference item bank was supported by CFA tests of model fit (CFI = 0.986, TLI = 0.986. Furthermore, the data fit the GRM and showed good coverage across the pain interference continuum (threshold-parameters range: -3.04 to 3.44. The Dutch-Flemish PROMIS Pain Interference item bank has good cross-cultural validity (only two out of 40 items showing DIF, good reliability (Cronbach's alpha = 0.98, and good construct validity (Pearson correlations between 0.62 and 0.75. A computer adaptive test (CAT and Dutch-Flemish PROMIS short forms of the Dutch-Flemish PROMIS Pain Interference item bank can now be developed.

  19. Research on Bridge Sensor Validation Based on Correlation in Cluster

    Directory of Open Access Journals (Sweden)

    Huang Xiaowei

    2016-01-01

    Full Text Available In order to avoid the false alarm and alarm failure caused by sensor malfunction or failure, it has been critical to diagnose the fault and analyze the failure of the sensor measuring system in major infrastructures. Based on the real time monitoring of bridges and the study on the correlation probability distribution between multisensors adopted in the fault diagnosis system, a clustering algorithm based on k-medoid is proposed, by dividing sensors of the same type into k clusters. Meanwhile, the value of k is optimized by a specially designed evaluation function. Along with the further study of the correlation of sensors within the same cluster, this paper presents the definition and corresponding calculation algorithm of the sensor’s validation. The algorithm is applied to the analysis of the sensor data from an actual health monitoring system. The result reveals that the algorithm can not only accurately measure the failure degree and orientate the malfunction in time domain but also quantitatively evaluate the performance of sensors and eliminate error of diagnosis caused by the failure of the reference sensor.

  20. The development and validation of a custom built device for assessing frontal knee joint laxity.

    Science.gov (United States)

    Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos

    2017-12-01

    This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Source Determination of Red Gel Pen Inks using Raman Spectroscopy and Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy combined with Pearson's Product Moment Correlation Coefficients and Principal Component Analysis.

    Science.gov (United States)

    Mohamad Asri, Muhammad Naeim; Mat Desa, Wan Nur Syuhaila; Ismail, Dzulkiflee

    2018-01-01

    The potential combination of two nondestructive techniques, that is, Raman spectroscopy (RS) and attenuated total reflectance-fourier transform infrared (ATR-FTIR) spectroscopy with Pearson's product moment correlation (PPMC) coefficient (r) and principal component analysis (PCA) to determine the actual source of red gel pen ink used to write a simulated threatening note, was examined. Eighteen (18) red gel pens purchased from Japan and Malaysia from November to December 2014 where one of the pens was used to write a simulated threatening note were analyzed using RS and ATR-FTIR spectroscopy, respectively. The spectra of all the red gel pen inks including the ink deposited on the simulated threatening note gathered from the RS and ATR-FTIR analyses were subjected to PPMC coefficient (r) calculation and principal component analysis (PCA). The coefficients r = 0.9985 and r = 0.9912 for pairwise combination of RS and ATR-FTIR spectra respectively and similarities in terms of PC1 and PC2 scores of one of the inks to the ink deposited on the simulated threatening note substantiated the feasibility of combining RS and ATR-FTIR spectroscopy with PPMC coefficient (r) and PCA for successful source determination of red gel pen inks. The development of pigment spectral library had allowed the ink deposited on the threatening note to be identified as XSL Poppy Red (CI Pigment Red 112). © 2017 American Academy of Forensic Sciences.

  2. Impact of correlations between core configurations for the evaluation of nuclear data uncertainty propagation for reactivity

    International Nuclear Information System (INIS)

    Frosio, T.; Bonaccorsi, T.; Blaise, P.

    2017-01-01

    The precise estimation of Pearson correlations, also called 'representativity' coefficients, between core configurations is a fundamental quantity for properly assessing the nuclear data (ND) uncertainties propagation on integral parameters such as k-eff, power distributions, or reactivity coefficients. In this paper, a traditional adjoint method is used to propagate ND uncertainty on reactivity and reactivity coefficients and estimate correlations between different states of the core. We show that neglecting those correlations induces a loss of information in the final uncertainty. We also show that using approximate values of Pearson does not lead to an important error of the model. This calculation is made for reactivity at the beginning of life and can be extended to other parameters during depletion calculations. (authors)

  3. Concurrent Validation of the Clinical Opiate Withdrawal Scale (COWS) and Single-Item Indices against the Clinical Institute Narcotic Assessment (CINA) Opioid Withdrawal Instrument

    Science.gov (United States)

    Tompkins, D. Andrew; Bigelow, George E.; Harrison, Joseph A.; Johnson, Rolley E.; Fudala, Paul J.; Strain, Eric C.

    2009-01-01

    Introduction The Clinical Opiate Withdrawal Scale (COWS) is an 11-item clinician-administered scale assessing opioid withdrawal. Though commonly used in clinical practice, it has not been systematically validated. The present study validated the COWS in comparison to the validated Clinical Institute Narcotic Assessment (CINA) scale. Method Opioid-dependent volunteers were enrolled in a residential trial and stabilized on morphine 30 mg given subcutaneously four times daily. Subjects then underwent double-blind, randomized challenges of intramuscularly administered placebo and naloxone (0.4 mg) on separate days, during which the COWS, CINA, and visual analog scale (VAS) assessments were concurrently obtained. Subjects completing both challenges were included (N=46). Correlations between mean peak COWS and CINA scores as well as self-report VAS questions were calculated. Results Mean peak COWS and CINA scores of 7.6 and 24.4, respectively, occurred on average 30 minutes post-injection of naloxone. Mean COWS and CINA scores 30 minutes after placebo injection were 1.3 and 18.9, respectively. The Pearson correlation coefficient for peak COWS and CINA scores during the naloxone challenge session was 0.85 (p<0.001). Peak COWS scores also correlated well with peak VAS self-report scores of bad drug effect (r=0.57, p<0.001) and feeling sick (r=0.57, p<0.001), providing additional evidence of concurrent validity. Placebo was not associated with any significant elevation of COWS, CINA, or VAS scores, indicating discriminant validity. Cronbach’s alpha for the COWS was 0.78, indicating good internal consistency (reliability). Discussion COWS, CINA, and certain VAS items are all valid measurement tools for acute opiate withdrawal. PMID:19647958

  4. Assessing patient-caregiver communication in cancer--a psychometric validation of the Cancer Communication Assessment Tool (CCAT-PF) in a German sample.

    Science.gov (United States)

    Haun, Markus W; Sklenarova, Halina; Winkler, Eva C; Huber, Johannes; Thomas, Michael; Siminoff, Laura A; Woll, Michael; Brechtel, Anette; Herzog, Wolfgang; Hartmann, Mechthild

    2014-09-01

    The recently introduced Cancer Communication Assessment Tool (CCAT-PF) measures congruence in patient-caregiver communication and was initially validated in lung cancer patients. Contributing to a greater proportion of the variance in the conflict scores, primary caregivers were hypothesized to experience greater stress. For a detailed understanding of conflicting communication patterns of cancer-affected families, our study aimed for psychometric validation of the CCAT-PF in a sample covering heterogeneous tumor entities. Subsequent to a cross-sectional survey of 189 pairs of cancer patients (31 % gastrointestinal, 34 % lung, and 35 % urological) and their caregivers' exploratory factor analysis with principal component condensation and varimax rotation was conducted (response rate, 74.2 %). Reliability and construct validity were assessed calculating Cronbach's α and Pearson correlation coefficients for CCAT-P and CCAT-F scales and related constructs, respectively. Cancer-related communication according to the CCAT-PF can be subdivided into four factors including the scales Disclosure, Limitation of treatment, Family involvement in treatment decisions, and Continuing treatment. Reliability ranged from α = .51-.68. The Disclosure scale, describing poor cancer-related communication of the patient, was correlated with patient's distress (QSC-R10: r = .30, p reliable stand-alone instrument for identifying conflicting communication in patient-caregiver-dyads at risk.

  5. The use of biweight mid correlation to improve graph based portfolio construction

    OpenAIRE

    Veenstra, Patrick; Cooper, Colin; Phelps, Steve

    2017-01-01

    An analysis of the correlation between the returns of different securities is of fundamental importance in many areas of finance, such as portfolio optimisation. The most commonly used measure of correlation is the Pearson correlation coefficient; however, this suffers from several problems when applied to data from the real world. We propose an alternative estimator - the Biweight Mid Correlation (Bicor) - as a more robust measure for capturing the relationship between returns. We systematic...

  6. Reliability and validity of the adapted Greek version of scoliosis research society – 22 (SRS-22 questionnaire

    Directory of Open Access Journals (Sweden)

    Christodoulou Evangelos A

    2009-07-01

    Full Text Available Abstract Background The SRS-22 is a valid instrument for the assessment of the health related quality of life of patients with Idiopathic scoliosis. The SRS-22 questionnaire was developed in USA and has been widely used in the English speaking countries. Recently it has been translated and validated in many other languages. The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the refined Scoliosis Research Society-22 Questionnaire. Methods Following the steps of cross – cultural adaptation the adapted Greek version of the SRS-22 questionnaire and a validated Greek version of the SF-36 questionnaire were mailed to 68 patients treated surgically for Idiopathic Scoliosis. 51 out of the 68 patients returned the 1st set of questionnaires, while a second set was emailed to 30 randomly selected patients of the first time responders. 20 out of the 30 patients returned the 2nd set. The mean age at the time of operation was16,2 years and the mean age at the time of evaluation was 21,2 years. Descriptive statistics for content analysis were calculated. Reliability assessment was determined by estimating Cronbach's α and intraclass correlation coefficient (ICC respectively. Concurrent validity was evaluated by comparing SRS-22 domains with relevant domains in the SF-36 questionnaire using Pearson's Correlation Coefficient (r. Results The calculated Cronbach's α of internal consistency for three of the corresponding domains (pain 0.85; mental health 0.87; self image 0.83 were very satisfactory and for two domains (function/activity 0.72 and satisfaction 0.67 were good. The ICC of all domains of SRS-22 questionnaire was high (ICC>0.70, demonstrating very satisfactory or excellent test/retest reproducibility. Considering concurrent validity all correlations were found to be statistically significant at the 0.01 level among related domains and generally demonstrated high correlation coefficient. Conclusion

  7. Validation of an Arabic version of the Diabetes Treatment Satisfaction Questionnaire in Qatar.

    Science.gov (United States)

    Wilbur, Kerry; Al Hammaq, Abdulla O

    2016-03-01

    Several instruments evaluate patient-reported outcomes in diabetes mellitus (DM), but almost none are validated for use in Arabic language. The aim of this study is to test the psychometric properties and responsiveness of the Arabic version of the Diabetes Treatment Satisfaction Questionnaire (DTSQs) in Qatar. Ambulatory Arabic speaking DM patients were interviewed at two consecutive time points in Doha, Qatar. The 8-item DTSQs was administered in conjunction with the Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36) and the World Health Organization Quality of Life Measure (WHOQOL-Bref) to assess convergent validity. Reliability was evaluated by internal consistency and item analysis. Construct validity was evaluated using "known groups" comparisons (including gender, insulin use, and HbA1c). Sensitivity of DTSQs scores to the subject's metabolic conditions was determined. One hundred subjects (mean age 50.7) participated. Half (54%) were female. The majority (93%) had Type 2 DM, but 39 (42%) were using insulin. Results revealed satisfactory internal consistency. Metabolic measures (fasting blood glucose and AIC) had significant inverse correlations with DTSQs scores (interview 1, Pearson's r=-0.333 and r=-0.401, respectively, pQatar Arabic DTSQs version was found to be a reliable and valid instrument for the assessment of treatment satisfaction in Arabic diabetes mellitus patients in the country. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Spanish validation of the Premorbid Adjustment Scale (PAS-S).

    Science.gov (United States)

    Barajas, Ana; Ochoa, Susana; Baños, Iris; Dolz, Montse; Villalta-Gil, Victoria; Vilaplana, Miriam; Autonell, Jaume; Sánchez, Bernardo; Cervilla, Jorge A; Foix, Alexandrina; Obiols, Jordi E; Haro, Josep Maria; Usall, Judith

    2013-02-01

    The Premorbid Adjustment Scale (PAS) has been the most widely used scale to quantify premorbid status in schizophrenia, coming to be regarded as the gold standard of retrospective assessment instruments. To examine the psychometric properties of the Spanish version of the PAS (PAS-S). Retrospective study of 140 individuals experiencing a first episode of psychosis (n=77) and individuals who have schizophrenia (n=63), both adult and adolescent patients. Data were collected through a socio-demographic questionnaire and a battery of instruments which includes the following scales: PAS-S, PANSS, LSP, GAF and DAS-sv. The Cronbach's alpha was performed to assess the internal consistency of PAS-S. Pearson's correlations were performed to assess the convergent and discriminant validity. The Cronbach's alpha of the PAS-S scale was 0.85. The correlation between social PAS-S and total PAS-S was 0.85 (p<0.001); while for academic PAS-S and total PAS-S it was 0.53 (p<0.001). Significant correlations were observed between all the scores of each age period evaluated across the PAS-S scale, with a significance value less than 0.001. There was a relationship between negative symptoms and social PAS-S (0.20, p<0.05) and total PAS-S (0.22, p<0.05), but not with academic PAS-S. However, there was a correlation between academic PAS-S and general subscale of the PANSS (0.19, p<0.05). Social PAS-S was related to disability measures (DAS-sv); and academic PAS-S showed discriminant validity with most of the variables of social functioning. PAS-S did not show association with the total LSP scale (discriminant validity). The Spanish version of the Premorbid Adjustment Scale showed appropriate psychometric properties in patients experiencing a first episode of psychosis and who have a chronic evolution of the illness. Moreover, each domain of the PAS-S (social and academic premorbid functioning) showed a differential relationship to other characteristics such as psychotic symptoms, disability

  9. Effects of different correlation metrics and preprocessing factors on small-world brain functional networks: a resting-state functional MRI study.

    Science.gov (United States)

    Liang, Xia; Wang, Jinhui; Yan, Chaogan; Shu, Ni; Xu, Ke; Gong, Gaolang; He, Yong

    2012-01-01

    Graph theoretical analysis of brain networks based on resting-state functional MRI (R-fMRI) has attracted a great deal of attention in recent years. These analyses often involve the selection of correlation metrics and specific preprocessing steps. However, the influence of these factors on the topological properties of functional brain networks has not been systematically examined. Here, we investigated the influences of correlation metric choice (Pearson's correlation versus partial correlation), global signal presence (regressed or not) and frequency band selection [slow-5 (0.01-0.027 Hz) versus slow-4 (0.027-0.073 Hz)] on the topological properties of both binary and weighted brain networks derived from them, and we employed test-retest (TRT) analyses for further guidance on how to choose the "best" network modeling strategy from the reliability perspective. Our results show significant differences in global network metrics associated with both correlation metrics and global signals. Analysis of nodal degree revealed differing hub distributions for brain networks derived from Pearson's correlation versus partial correlation. TRT analysis revealed that the reliability of both global and local topological properties are modulated by correlation metrics and the global signal, with the highest reliability observed for Pearson's-correlation-based brain networks without global signal removal (WOGR-PEAR). The nodal reliability exhibited a spatially heterogeneous distribution wherein regions in association and limbic/paralimbic cortices showed moderate TRT reliability in Pearson's-correlation-based brain networks. Moreover, we found that there were significant frequency-related differences in topological properties of WOGR-PEAR networks, and brain networks derived in the 0.027-0.073 Hz band exhibited greater reliability than those in the 0.01-0.027 Hz band. Taken together, our results provide direct evidence regarding the influences of correlation metrics and specific

  10. Effects of different correlation metrics and preprocessing factors on small-world brain functional networks: a resting-state functional MRI study.

    Directory of Open Access Journals (Sweden)

    Xia Liang

    Full Text Available Graph theoretical analysis of brain networks based on resting-state functional MRI (R-fMRI has attracted a great deal of attention in recent years. These analyses often involve the selection of correlation metrics and specific preprocessing steps. However, the influence of these factors on the topological properties of functional brain networks has not been systematically examined. Here, we investigated the influences of correlation metric choice (Pearson's correlation versus partial correlation, global signal presence (regressed or not and frequency band selection [slow-5 (0.01-0.027 Hz versus slow-4 (0.027-0.073 Hz] on the topological properties of both binary and weighted brain networks derived from them, and we employed test-retest (TRT analyses for further guidance on how to choose the "best" network modeling strategy from the reliability perspective. Our results show significant differences in global network metrics associated with both correlation metrics and global signals. Analysis of nodal degree revealed differing hub distributions for brain networks derived from Pearson's correlation versus partial correlation. TRT analysis revealed that the reliability of both global and local topological properties are modulated by correlation metrics and the global signal, with the highest reliability observed for Pearson's-correlation-based brain networks without global signal removal (WOGR-PEAR. The nodal reliability exhibited a spatially heterogeneous distribution wherein regions in association and limbic/paralimbic cortices showed moderate TRT reliability in Pearson's-correlation-based brain networks. Moreover, we found that there were significant frequency-related differences in topological properties of WOGR-PEAR networks, and brain networks derived in the 0.027-0.073 Hz band exhibited greater reliability than those in the 0.01-0.027 Hz band. Taken together, our results provide direct evidence regarding the influences of correlation metrics

  11. Motor competence assessment in children: convergent and discriminant validity between the BOT-2 Short Form and KTK testing batteries.

    Science.gov (United States)

    Fransen, Job; D'Hondt, Eva; Bourgois, Jan; Vaeyens, Roel; Philippaerts, Renaat M; Lenoir, Matthieu

    2014-06-01

    This study investigated convergent and discriminant validity between two motor competence assessment instruments in 2485 Flemish children: the Bruininks-Oseretsky Test of Motor Proficiency 2 Short Form (BOT-2 Short Form) and the KörperKoördinationsTest für Kinder (KTK). A Pearson correlation assessed the relationship between BOT-2 Short Form total, gross and fine motor composite scores and KTK Motor Quotient in three age cohorts (6-7, 8-9, 10-11 years). Crosstabs were used to measure agreement in classification in children scoring below percentile 5 and 15 and above percentile 85 and 95. Moderately strong positive (r=0.44-0.64) associations between BOT-2 total and gross motor composite scores and KTK Motor Quotient and weak positive correlations between BOT-2 Short Form fine motor composite and KTK Motor Quotient scores (r=0.25-0.37) were found. Levels of agreement were fair to moderate. Therefore, some proof of convergent and discriminant validity between BOT-2 Short Form and KTK was established in this study, underlining the notion that the evaluation of motor competence should not be based upon a single assessment instrument. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. A hybrid correlation analysis with application to imaging genetics

    Science.gov (United States)

    Hu, Wenxing; Fang, Jian; Calhoun, Vince D.; Wang, Yu-Ping

    2018-03-01

    Investigating the association between brain regions and genes continues to be a challenging topic in imaging genetics. Current brain region of interest (ROI)-gene association studies normally reduce data dimension by averaging the value of voxels in each ROI. This averaging may lead to a loss of information due to the existence of functional sub-regions. Pearson correlation is widely used for association analysis. However, it only detects linear correlation whereas nonlinear correlation may exist among ROIs. In this work, we introduced distance correlation to ROI-gene association analysis, which can detect both linear and nonlinear correlations and overcome the limitation of averaging operations by taking advantage of the information at each voxel. Nevertheless, distance correlation usually has a much lower value than Pearson correlation. To address this problem, we proposed a hybrid correlation analysis approach, by applying canonical correlation analysis (CCA) to the distance covariance matrix instead of directly computing distance correlation. Incorporating CCA into distance correlation approach may be more suitable for complex disease study because it can detect highly associated pairs of ROI and gene groups, and may improve the distance correlation level and statistical power. In addition, we developed a novel nonlinear CCA, called distance kernel CCA, which seeks the optimal combination of features with the most significant dependence. This approach was applied to imaging genetic data from the Philadelphia Neurodevelopmental Cohort (PNC). Experiments showed that our hybrid approach produced more consistent results than conventional CCA across resampling and both the correlation and statistical significance were increased compared to distance correlation analysis. Further gene enrichment analysis and region of interest (ROI) analysis confirmed the associations of the identified genes with brain ROIs. Therefore, our approach provides a powerful tool for finding

  13. The correlation of serum asymmetric dimethylarginine and anti-Müllerian hormone in primary dysmenorrhea

    Directory of Open Access Journals (Sweden)

    Nermin Akdemir

    2016-08-01

    Full Text Available In this study, we aimed to investigate the association of serum asymmetric dimethylarginine (ADMA and anti-Müllerian hormone (AMH levels in primary dysmenorrhea patients. The study employed a cross-sectional design. Eighty-nine female university students with primary dysmenorrhea were included in the study. All patients underwent complete clinical and laboratory investigations, including serum ADMA, AMH levels, pelvic ultrasonography, electrocardiography, and echocardiography. Pearson correlation and linear regression analysis were used to evaluate associations between continuous data. Categorical associations were evaluated using χ2 test. Correlation analysis between serum ADMA and AMH levels in the study group showed a highly significant positive relationship (Pearson correlation = 0.978, p = 0.01. Our study has shown a significant positive correlation between serum ADMA and AMH levels in primary dysmenorrhea. Serum ADMA levels may have the potential to demonstrate ovarian reserve.

  14. Development of a Saudi Food Frequency Questionnaire and testing its reliability and validity.

    Science.gov (United States)

    Gosadi, Ibrahim M; Alatar, Abdullah A; Otayf, Mojahed M; AlJahani, Dhaherah M; Ghabbani, Hisham M; AlRajban, Waleed A; Alrsheed, Abdullah M; Al-Nasser, Khalid A

    2017-06-01

    To create a food frequency questionnaire specifically designed to capture the dietary habits of Saudis and test its validity and reliability. Methods: This investigation is a longitudinal, test-retest study conducted in King Saud University, Riyadh, Kingdom of Saudi Arabia between December 2015 and March 2016. A list of 140 food items was included in the questionnaire where a closed-ended and open-ended approach was used. Regarding past   year food frequency consumption and 24 hours dietary recall, body weight and height were collected. Internal consistency, test-retest reliability, completeness of the food list, and criterion validity were assessed. Results: One-hundred and thirty eight participants were interviewed to complete the 24 hours dietary recall and the constructed questionnaire. Approximately 85% of the food items reported in the dietary recall were covered in the food frequency questionnaire. The association of body mass index with meats (regression coefficients: 2.28) and dairy products consumption frequency was statistically significant (regression coefficients: 2.31). A high overall reproducibility rate of the questionnaire was detected (Pearsons' correlation coefficient: 0.78 p less than 0.001).  Conclusion: The developed questionnaire has a high reliability and reasonable validity, and suitable for use in nutritional epidemiological investigations in Saudi Arabia.

  15. Validity of a short questionnaire to assess physical activity in 10 European countries.

    Science.gov (United States)

    Peters, Tricia; Brage, Soren; Westgate, Kate; Franks, Paul W; Gradmark, Anna; Tormo Diaz, Maria Jose; Huerta, Jose Maria; Bendinelli, Benedetta; Vigl, Mattheaus; Boeing, Heiner; Wendel-Vos, Wanda; Spijkerman, Annemieke; Benjaminsen-Borch, Kristin; Valanou, Elisavet; de Lauzon Guillain, Blandine; Clavel-Chapelon, Françoise; Sharp, Stephen; Kerrison, Nicola; Langenberg, Claudia; Arriola, Larraitz; Barricarte, Aurelio; Gonzales, Carlos; Grioni, Sara; Kaaks, Rudolf; Key, Timothy; Khaw, Kay Tee; May, Anne; Nilsson, Peter; Norat, Teresa; Overvad, Kim; Palli, Domenico; Panico, Salvatore; Ramón Quirós, Jose; Ricceri, Fulvio; Sanchez, Maria-Jose; Slimani, Nadia; Tjonneland, Anne; Tumino, Rosario; Feskins, Edith; Riboli, Elio; Ekelund, Ulf; Wareham, Nick

    2012-01-01

    To accurately examine associations of physical activity (PA) with disease outcomes, a valid method of assessing free-living activity is required. We examined the validity of a brief PA questionnaire (PAQ) used in the European Prospective Investigation into Cancer and Nutrition (EPIC). PA energy expenditure (PAEE) and time spent in moderate and vigorous physical activity (MVPA) was measured in 1,941 healthy individuals from 10 European countries using individually-calibrated combined heart-rate and movement sensing. Participants also completed the short EPIC-PAQ, which refers to past year's activity. Pearson (r) and Spearman (σ) correlation coefficients were calculated for each country, and random effects meta-analysis was used to calculate the combined correlation across countries to estimate the validity of two previously- and one newly-derived ordered, categorical PA indices ("Cambridge index", "total PA index", and "recreational index") that categorized individuals as inactive, moderately inactive, moderately active, or active. The strongest associations with PAEE and MVPA were observed for the Cambridge index (r = 0.33 and r = 0.25, respectively). No significant heterogeneity by country was observed for this index (I(2) = 36.3%, P = 0.12; I(2) = 0.0%, P = 0.85), whereas heterogeneity was suggested for other indices (I(2) > 48%, P  47%, P PAQ is suitable for categorizing European men and women into four distinct categories of overall physical activity. The difference in PAEE between categories may be useful when estimating effect sizes from observational research.

  16. Portuguese version of the EUROPEP questionnaire: contributions to the psychometric validation

    Directory of Open Access Journals (Sweden)

    Hugo Roque

    Full Text Available ABSTRACT OBJECTIVE To assess the construct validity and reliability of the Portuguese version of the European Task Force on Patient Evaluation of General Practice Care questionnaire. METHODS We applied the Portuguese version of the European Task Force on Patient Evaluation of General Practice Care to 392 users of 20 Family Health Units from the North of Portugal. The validity of the construct was evaluated by exploratory factor analysis, with the Principal Axis Factoring method, by orthogonal rotation (varimax procedure, by the Kaiser normalization criteria (eigenvalue ≥ 1. The factorability of the data matrix was verified by the Kaiser-Meyer-Olkin and Bartlett’s sphericity test. We estimated the reliability by the indicator of internal consistency Cronbach’s alpha. To analyze the correlations between satisfaction and loyalty, we used the Pearson correlations. The predictor effect of satisfaction on loyalty was analyzed by simple linear regression. RESULTS Satisfaction presented five robust and well individualized dimensions – medical care, nursing care, clinical secretariat services, accessibility, and organization of services – with alpha values between 0.86 and 0.97, good levels of internal consistency. The loyalty showed alpha value of 0.72, considered a reasonable internal consistency. The satisfaction was predictive of loyalty. CONCLUSIONS The Portuguese European Task Force on Patient Evaluation of General Practice Care questionnaire is a robust and reliable instrument to measure the satisfaction and loyalty of users of the Family Health Units.

  17. Reliability and validity of the Youth Leisure-time Sedentary Behavior Questionnaire (YLSBQ).

    Science.gov (United States)

    Cabanas-Sánchez, Verónica; Martínez-Gómez, David; Esteban-Cornejo, Irene; Castro-Piñero, José; Conde-Caveda, Julio; Veiga, Óscar L

    2018-01-01

    To develop a questionnaire able to assess time spent by youth in a wide range of leisure-time sedentary behaviors (SB) and evaluate its test-retest reliability and criterion validity. Cross-sectional observational. The reliability sample included 194 youth, aged 10-18 years, who completed the questionnaire twice, separated by one-week interval. The validity study comprised 1207 participants aged 8-18 years. Participants wore an accelerometer for 7 consecutive days. The questionnaire was designed to assess the amount of time spent in twelve different SB during weekdays and weekends, separately. In order to avoid usual phenomenon of time over reporting, values were adjusted to real available leisure-time (LT) for each participant. Reliability was assessed by using Intraclass Correlation Coefficients (ICC) and weighted (quadratic) kappa (k), and validity was assessed by using Pearson correlation and Bland-Altman plots. The reliability of questionnaire showed a moderate-to-substantial agreement for the most (91%) of items (k=0.43-0.74; ICC=0.41-0.79) with three items (4%) reaching an almost perfect agreement (ICC=0.82-0.83). Only 'sitting and talking' evidenced fair-to-moderate reliability (k=0.27-0.39; ICC=0.34-0.46). The relationship between average sedentary time assessed by the questionnaire and accelerometry was moderate (r=0.36; pquestionnaire and accelerometer sedentary time for average day (r=0.05; p=0.11) but Bland-Altman plots suggest moderate discrepancies between both methods of SB measurement (mean=19.86; limits of agreement=-280.04 to 319.76). The questionnaire showed moderate to good test-retest reliability and a moderate level of validity for assessing SB in youth, similar or slightly better to previously published in this population. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Comparison of blood levels of riboflavin and folate with dietary correlates estimated from a semi-quantitative food-frequency questionnaire in older persons in Portugal.

    Science.gov (United States)

    Tavares, Nelson R; Moreira, Pedro S; Amaral, Teresa F

    2012-01-01

    Since information regarding biochemical parameters of riboflavin and folate status is limited in some populations of older adults, a food-frequency questionnaire is often used to estimate riboflavin and folate status. However, the performance of this type of questionnaire among this age group has not been comprehensively evaluated. Thus, we sought to assess riboflavin and folate status in older adults living in Portugal and to validate findings from a semiquantitative food-frequency questionnaire (FFQ), by comparison to these blood measures. We used a cross-sectional study to investigate riboflavin in red blood cells (as Glutathione Reductase Activity Coefficient; EGRAC) and folate in the serum of 88 older persons (66.7% female), aged between 60 and 94 years, recruited from seven adult day care community centers in Porto, Portugal. Forty-six subjects had low EGRAC levels (riboflavin dietary intakes from FFQ, the mean was 3.34 mg, the median 3.37 mg, and range 0.66-4.81 mg. The Spearman correlation between these two measures was r = 0.073, (P = 0.497) and Pearson correlation, after adjustment for energy, was r = 0.263, P = 0.013. All participants were above the 7 nmol/L serum folate cut-off for adequacy. Spearman correlation coefficient between serum and FFQ measures was r = -0.10, (P = 0.359), and the Pearson correlation, after adjustment for energy and following log(e) transformation, was r = -0.58, (P = 0.593). Thus riboflavin and folate intakes estimated by FFQ correlated poorly with EGRAC and folate serum values.

  19. Collective Correlations of Brodmann Areas fMRI Study with RMT-Denoising

    Science.gov (United States)

    Burda, Z.; Kornelsen, J.; Nowak, M. A.; Porebski, B.; Sboto-Frankenstein, U.; Tomanek, B.; Tyburczyk, J.

    We study collective behavior of Brodmann regions of human cerebral cortex using functional Magnetic Resonance Imaging (fMRI) and Random Matrix Theory (RMT). The raw fMRI data is mapped onto the cortex regions corresponding to the Brodmann areas with the aid of the Talairach coordinates. Principal Component Analysis (PCA) of the Pearson correlation matrix for 41 different Brodmann regions is carried out to determine their collective activity in the idle state and in the active state stimulated by tapping. The collective brain activity is identified through the statistical analysis of the eigenvectors to the largest eigenvalues of the Pearson correlation matrix. The leading eigenvectors have a large participation ratio. This indicates that several Broadmann regions collectively give rise to the brain activity associated with these eigenvectors. We apply random matrix theory to interpret the underlying multivariate data.

  20. Bias-corrected Pearson estimating functions for Taylor's power law applied to benthic macrofauna data

    DEFF Research Database (Denmark)

    Jørgensen, Bent; Demétrio, Clarice G. B.; Kristensen, Erik

    2011-01-01

    Estimation of Taylor’s power law for species abundance data may be performed by linear regression of the log empirical variances on the log means, but this method suffers from a problem of bias for sparse data. We show that the bias may be reduced by using a bias-corrected Pearson estimating...

  1. Cross-cultural Adaptation, Reliability, and Validity of the Yoruba Version of the Roland-Morris Disability Questionnaire.

    Science.gov (United States)

    Mbada, Chidozie Emmanuel; Idowu, Opeyemi Ayodiipo; Ogunjimi, Olawale Richard; Ayanniyi, Olusola; Orimolade, Elkanah Ayodele; Oladiran, Ajibola Babatunde; Johnson, Olubusola Esther; Akinsulore, Adesanmi; Oni, Temitope Olawale

    2017-04-01

    A translation, cross-cultural adaptation, and psychometric analysis. The aim of this study was to translate, cross-culturally adapt, and validate the Yoruba version of the RMDQ. The Roland-Morris Disability Questionnaire (RMDQ) is a valid outcome tool for low back pain (LBP) in clinical and research settings. There seems to be no valid and reliable version of the RMDQ in the Nigerian languages. Following the Guillemin criteria, the English version of the RMDQ was forward and back translated. Two Yoruba translated versions of the RMDQ were assessed for clarity, common language usage, and conceptual equivalence. Consequently, a harmonized Yoruba version was produced and was pilot-tested among 20 patients with nonspecific long-term LBP (NSLBP) for cognitive debriefing. The final version of the Yoruba RMDQ was tested for its construct validity and re-retest reliability among 120 and 87 patients with NSLBP, respectively. Pearson product moment correlation coefficient (r) of 0.82 was obtained for reliability of the Yoruba version of the RMDQ. The test-retest reliability of the Yoruba RMDQ yielded Cronbach alpha 0.932, while the intraclass correlation (ICC) ranged between 0.896 and 0.956. The analysis of the global scores of both the English and Yoruba versions of the RMDQ yielded ICC value of between 0.995 (95% confidence interval 0.996-0.997), with the item-by-item Kappa agreement ranging between 0.824 and 1.000. The external validity of RMDQ using Quadruple Visual Analogue Scale was r = -0.596 (P = 0.001). The Yoruba version of the RMDQ had no floor/ceiling effects, as no patient achieved either of the maximum or the minimum possible scores. The Yoruba version of the RMDQ has excellent reliability and validity and may be an appropriate outcome tool for clinical and research purposes among Yoruba-speaking patients with LBP. 3.

  2. Greek cultural adaption and validation of the Kujala anterior knee pain scale in patients with patellofemoral pain syndrome.

    Science.gov (United States)

    Papadopoulos, Costas; Constantinou, Antonis; Cheimonidou, Areti-Zoi; Stasinopoulos, Dimitrios

    2017-04-01

    To cross-culturally adapt and validate the Greek version of the Kujala anterior knee pain scale (KAKPS). The Greek KAKPS was translated from the original English version following standard forward and backward translation procedures. The survey was then conducted in clinical settings by a questionnaire comprising the Greek KAKPS and patellofemoral pain syndrome (PFPS) severity scale. A total of 130 (62 women and 68 men) Greek-reading patients between 18 and 45 years old with anterior knee pain (AKP) for at least four weeks were recruited from physical therapy clinics. To establish test-retest reliability, the patients were asked to complete the KAKPS at initial visit and 2-3 days after the initial visit. The Greek version of the PFPS severity scale was also administered once at initial visit. Internal consistency of the translated instrument was measured using Cronbach's α. An intraclass correlation coefficient was used to assess the test-retest reliability of the KAKPS. Concurrent validity was measured by correlating the KAKPS with the PFPS severity scale using Pearson's correlation coefficient. The results showed that the Greek KAKPS has good internal consistency (Cronbach's α = 0.942), test-retest reliability (ICC = 0.921) and concurrent validity (r > 0.7). This study has shown that the Greek KAKPS has good internal consistency, test-retest reliability and concurrent validity when correlated with the PFPS severity scale in adult patients with AKP for at least four weeks. Implications for rehabilitation The Greek version of the KAKPS has been found to be reliable and valid when used in adult patients with AKP for at least four weeks. The results of the psychometric characteristics were compatible with those of the original English version. The KAKPS could be applied in a Greek-speaking population to assess functional limitations and symptoms in patients aged 18-45 years old with AKP for at least four weeks.

  3. Accuracy of clinical observations of push-off during gait after stroke.

    Science.gov (United States)

    McGinley, Jennifer L; Morris, Meg E; Greenwood, Ken M; Goldie, Patricia A; Olney, Sandra J

    2006-06-01

    To determine the accuracy (criterion-related validity) of real-time clinical observations of push-off in gait after stroke. Criterion-related validity study of gait observations. Rehabilitation hospital in Australia. Eleven participants with stroke and 8 treating physical therapists. Not applicable. Pearson product-moment correlation between physical therapists' observations of push-off during gait and criterion measures of peak ankle power generation from a 3-dimensional motion analysis system. A high correlation was obtained between the observational ratings and the measurements of peak ankle power generation (Pearson r =.98). The standard error of estimation of ankle power generation was .32W/kg. Physical therapists can make accurate real-time clinical observations of push-off during gait following stroke.

  4. Validade concorrente e confiabilidade da Alberta Infant Motor Scale em lactentes nascidos prematuros Concurrent validity and reliability of the Alberta Infant Motor Scale in premature infants

    Directory of Open Access Journals (Sweden)

    Kênnea Martins Almeida

    2008-10-01

    Full Text Available OBJETIVO: Verificar a validade concorrente e a confiabilidade interobservador da Alberta Infant Motor Scale (AIMS em lactentes prematuros acompanhados no ambulatório de seguimento do Instituto Fernandes Figueira, Fundação Oswaldo Cruz (IFF/Fiocruz. MÉTODOS: Foram avaliados 88 lactentes nascidos prematuros no ambulatório de seguimento do IFF/Fiocruz entre fevereiro e dezembro de 2006. No estudo de validade concorrente, 46 lactentes com 6 (n = 26 ou 12 (n = 20 meses de idade corrigida foram avaliados pela AIMS e pela escala motora da Bayley Scales of Infant Development, 2ª edição, por dois observadores diferentes, utilizando-se o coeficiente de correlação de Pearson para análise dos resultados. No estudo de confiabilidade, 42 lactentes entre 0 e 18 meses foram avaliados pela AIMS por dois observadores diferentes, utilizando-se o intraclass correlation coefficient (ICC para análise dos resultados. RESULTADOS: No estudo de validade concorrente, a correlação encontrada entre as duas escalas foi alta (r = 0,95 e estatisticamente significativa (p OBJECTIVE: To verify the concurrent validity and interobserver reliability of the Alberta Infant Motor Scale (AIMS in premature infants followed-up at the outpatient clinic of Instituto Fernandes Figueira, Fundação Oswaldo Cruz (IFF/Fiocruz, in Rio de Janeiro, Brazil. METHODS: A total of 88 premature infants were enrolled at the follow-up clinic at IFF/Fiocruz, between February and December of 2006. For the concurrent validity study, 46 infants were assessed at either 6 (n = 26 or 12 (n = 20 months' corrected age using the AIMS and the second edition of the Bayley Scales of Infant Development, by two different observers, and applying Pearson's correlation coefficient to analyze the results. For the reliability study, 42 infants between 0 and 18 months were assessed using the Alberta Infant Motor Scale, by two different observers and the results analyzed using the intraclass correlation

  5. Cross-cultural translation of the Lysholm knee score in Chinese and its validation in patients with anterior cruciate ligament injury.

    Science.gov (United States)

    Wang, W; Liu, L; Chang, X; Jia, Z Y; Zhao, J Z; Xu, W D

    2016-10-19

    The Lysholm Knee Score (LKS) is widely used and is one of the most effective questionnaires employed to assess knee injuries. Although LKS has been translated into multiple languages, there is no Chinese version even though China has the largest population of patients with knee-joint injuries. The objective of our study was to develop the Chinese version of LKS (C-LKS) and assess its reliability, validity and responsiveness in Chinese patients with anterior cruciate ligament (ACL) injuries. Study participants were mainly recruited among patients with ACL injuries scheduled for arthroscopic ACL reconstruction at our hospital. First, we developed the C-LKS in a five-step translation and cross-cultural adaptation procedure. Next, we calculated the Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) to evaluate the reliability, validity, and responsiveness of C-LKS respectively. Overall, 126 patients with ACL injuries successfully completed the questionnaires. Acceptable internal consistency (Cronbach's alpha = 0.726) as well as excellent test-retest reliability (ICC = 0.935) was found for C-LKS. Good or moderate correlation (r = 0.514-0.837) was determined among C-LKS and International Knee Documentation Committee Subjective Knee Form (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), physical subscales of SF-36; C-LKS also had fair or moderate correlation (r = 0.207-0.462) with the other subscales of SF-36, which adequately illustrated that good validity was included in C-LKS. In addition, good responsiveness was also observed in C-LKS (ES = 1.36,SRM = 1.26). We have shown that our developed C-LKS questionnaire is reliable, valid and responsible for the evaluation of Chinese-speaking patients with ACL injuries and it would be an effective instrument.

  6. Development and Validation of a Short-Form Safety Net Medical Home Scale.

    Science.gov (United States)

    Nocon, Robert S; Gunter, Kathryn E; Gao, Yue; Lee, Sang Mee; Chin, Marshall H

    2017-12-01

    To develop a short-form Safety Net Medical Home Scale (SNMHS) for assessing patient-centered medical home (PCMH) capability in safety net clinics. National surveys of federally qualified health centers (FQHCs). Interviews with FQHC directors. We constructed three short-form SNMHS versions and examined correlations with full SNMHS and related primary care assessments. We tested usability with FQHC directors and reviewed scale development with an advisory group. Federally qualified health center surveys were administered in 2009 and 2013, by mail and online. Usability testing was conducted through telephone interviews with FQHC directors in 2013. Six-, 12-, and 18-question short-form SNMHS versions had Pearson correlations with full scale of 0.84, 0.92, and 0.96, respectively. All versions showed a level of convergent validity with other primary care assessment scales comparable to the full SNMHS. User testers found short forms to be low-burden, though missing some PCMH concepts. Advisory group members expressed caution over missing concepts and appropriate use of short-form self-assessments. Short-form versions of SNMHS showed strong correlations with full scale and may be useful for brief assessment of safety net PCMH capability. Each short-form SNMHS version may be appropriate for different research, quality improvement, and assessment purposes. © Health Research and Educational Trust.

  7. Validity and reliability of the Rosenberg Self-Esteem Scale-Thai version as compared to the Self-Esteem Visual Analog Scale.

    Science.gov (United States)

    Piyavhatkul, Nawanant; Aroonpongpaisal, Suwanna; Patjanasoontorn, Niramol; Rongbutsri, Somchit; Maneeganondh, Somchit; Pimpanit, Wijitra

    2011-07-01

    To compare the validity and reliability of the Thai version of the Rosenberg Self-Esteem Scale with the Self-Esteem Visual Analog Scale. The Rosenberg Self-Esteem Scale was translated into Thai and its content-validity checked by bacA translation. The reliability of the Rosenberg Self-Esteem Scale compared with the Self-Esteem Visual Analog Scale was ther tested between February and March 2008 on 270 volunteers, including 135 patients with psychiatric illness and 135 normal volunteers. The authors analyzed the internal consistency and factor structure of the Rosenberg Self-Esteem Scale-Thai version and the correlation between it and the Visual Analog Scale. The Cronbach's Alpha for the Rosenberg Self-Esteem scale-Thai version was 0.849 and the Pearson's correlation between it and the Self-Esteem Visual Analog Scale 0.618 (p = 0.01). Two factors, viz, the positively and negatively framea items, from the Rosenberg Self-Esteem Scale-Thai version accounted for 44.04% and 12.10% of the variance, respectively. The Rosenberg Self-Esteem Scale-Thai version has acceptable reliability. The Self-Esteem Visual Analog Scale provides an effective measure of self-esteem.

  8. Reliability, validity, and sensitivity to change of the lower extremity functional scale in individuals affected by stroke.

    Science.gov (United States)

    Verheijde, Joseph L; White, Fred; Tompkins, James; Dahl, Peder; Hentz, Joseph G; Lebec, Michael T; Cornwall, Mark

    2013-12-01

    To investigate reliability, validity, and sensitivity to change of the Lower Extremity Functional Scale (LEFS) in individuals affected by stroke. The secondary objective was to test the validity and sensitivity of a single-item linear analog scale (LAS) of function. Prospective cohort reliability and validation study. A single rehabilitation department in an academic medical center. Forty-three individuals receiving neurorehabilitation for lower extremity dysfunction after stroke were studied. Their ages ranged from 32 to 95 years, with a mean of 70 years; 77% were men. Test-retest reliability was assessed by calculating the classical intraclass correlation coefficient, and the Bland-Altman limits of agreement. Validity was assessed by calculating the Pearson correlation coefficient between the instruments. Sensitivity to change was assessed by comparing baseline scores with end of treatment scores. Measurements were taken at baseline, after 1-3 days, and at 4 and 8 weeks. The LEFS, Short-Form-36 Physical Function Scale, Berg Balance Scale, Six-Minute Walk Test, Five-Meter Walk Test, Timed Up-and-Go test, and the LAS of function were used. The test-retest reliability of the LEFS was found to be excellent (ICC = 0.96). Correlated with the 6 other measures of function studied, the validity of the LEFS was found to be moderate to high (r = 0.40-0.71). Regarding the sensitivity to change, the mean LEFS scores from baseline to study end increased 1.2 SD and for LAS 1.1 SD. LEFS exhibits good reliability, validity, and sensitivity to change in patients with lower extremity impairments secondary to stroke. Therefore, the LEFS can be a clinically efficient outcome measure in the rehabilitation of patients with subacute stroke. The LAS is shown to be a time-saving and reasonable option to track changes in a patient's functional status. Copyright © 2013 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  9. Degree-degree correlations in directed networks with heavy-tailed degrees

    NARCIS (Netherlands)

    van der Hoorn, W.L.F.; Litvak, Nelli

    2013-01-01

    In network theory, Pearson's correlation coefficients are most commonly used to measure the degree assortativity of a network. We investigate the behavior of these coefficients in the setting of directed networks with heavy-tailed degree sequences. We prove that for graphs where the in- and

  10. Meta-Analysis of Correlations Among Usability Measures

    DEFF Research Database (Denmark)

    Hornbæk, Kasper Anders Søren; Effie Lai Chong, Law

    2007-01-01

    are generally low: effectiveness measures (e.g., errors) and efficiency measures (e.g., time) has a correlation of .247 ± .059 (Pearson's product-moment correlation with 95% confidence interval), efficiency and satisfaction (e.g., preference) one of .196 ± .064, and effectiveness and satisfaction one of .164......Understanding the relation between usability measures seems crucial to deepen our conception of usability and to select the right measures for usability studies. We present a meta-analysis of correlations among usability measures calculated from the raw data of 73 studies. Correlations...... ± .062. Changes in task complexity do not influence these correlations, but use of more complex measures attenuates them. Standard questionnaires for measuring satisfaction appear more reliable than homegrown ones. Measures of users' perceptions of phenomena are generally not correlated with objective...

  11. Involutional ectropion and entropion: clinicopathologic correlation between horizontal eyelid laxity and eyelid extracellular matrix.

    Science.gov (United States)

    Damasceno, Renato Wendell; Osaki, Midori Hentona; Dantas, Paulo Elias Correa; Belfort, Rubens

    2011-01-01

    To investigate the clinicopathologic correlation between horizontal eyelid laxity and extracellular matrix components, such as collagen and elastic fibers, in involutional ectropion and entropion. Another goal was to compare the differences between involutional ectropion and entropion in regard to extracellular matrix content using computer-assisted morphometry. This clinicopathologic study included 20 consecutive patients with involutional ectropion (group 1) and 20 consecutive patients with involutional entropion (group 2). The pinch test was performed to measure horizontal eyelid laxity in both groups. Full-thickness eyelid biopsy specimens were examined by light microscopy and computer-assisted morphometry. The Mann-Whitney U test, the Pearson chi-square test, the Pearson correlation coefficient calculation, and a linear regression analysis were performed. All sections of specimens from patients in groups 1 and 2 revealed abnormal collagen and elastic fibers. The Pearson correlation coefficient revealed a significant negative correlation between horizontal eyelid laxity and extracellular matrix content in the eyelid skin, the pretarsal orbicularis oculi muscle, the perimeibomian tarsal stroma, and the intermeibomian tarsal stroma. Linear regression demonstrated that horizontal eyelid laxity is dependent upon extracellular matrix components in all eyelid regions. Collagen fiber content was significantly increased in specimens from patients in group 1 compared with specimens from patients in group 2. The present findings suggest that a reduction of collagen and elastic fibers may contribute to the development of excessive horizontal eyelid laxity in patients with involutional ectropion and entropion of the lower eyelid.

  12. Validity and reliability of the TED-QOL: a new three-item questionnaire to assess quality of life in thyroid eye disease.

    Science.gov (United States)

    Fayers, Tessa; Dolman, Peter J

    2011-12-01

    To develop and test a user-friendly questionnaire for rapidly assessing quality of life (QOL) in thyroid eye disease (TED). A three-item questionnaire, the TED-QOL, was designed and compared to the 16-item Graves Ophthalmopathy (GO)-QOL and the nine-item GO-Quality of Life Scale (QLS). 100 patients with TED were administered all three questionnaires on two occasions. Results were compared to clinical severity scores (Vision, Inflammation, Strabismus, Appearance (VISA) classification). Main outcomes were construct and criterion validity, test-retest reliability, duration, comprehension and completion rates. TED-QOL correlated strongly with the other questionnaires for corresponding items (Pearson correlation: appearance 0.71, 0.62; functioning 0.69, 0.66; overall QOL 0.53). Test-retest analysis demonstrated good reliability for all three questionnaires (intraclass correlations: TED-QOL 0.81, 0.74, 0.87; GO-QOL 0.81, 0.82; GO-QLS 0.74, 0.86, 0.67). TED-QOL was significantly faster to complete (1.6 min vs GO-QOL 3.1 min, GO-QLS 2.7 min, p<0.0001) and had a higher completion rate (100% vs GO-QOL 78%, GO-QLS 94%). There was only moderate correlation between items on all three questionnaires and VISA scores. The TED-QOL is rapid and easy to complete and analyse and has similar validity and reliability to longer questionnaires. All questionnaires showed only moderate correlation with disease severity, emphasising the discrepancy between objective and subjective assessments and the importance of measuring both.

  13. Correlation between working positions and lactic acid levels with musculoskeletal complaints among dentists

    Directory of Open Access Journals (Sweden)

    Fiory Dioptis Putriwijaya

    2016-12-01

    Full Text Available Background: Musculoskeletal complaints have been common for dentists since their body is unknowingly often in inappropriate positions when caring for patients. For example, they bend towards patients, suddenly move, and then rotate from one side to another. The repetitive movements are done in long term. High activities and sufficient recovery time can cause a buildup of lactic acid in their blood leading to obstruction of the energy intake from the aerobic system in their muscle cells, resulting in fatigue. As a result, such conditions trigger decreased muscle performances. Purpose: This study aimed to determine the correlation between working positions and lactic acid levels with the risk of musculoskeletal disorders among dentists at Public Health Centers in Surabaya. Method: This research was an analytical observational research using cross sectional approach. Sampling technique used in this research was cluster random sampling with nineteen samples. To evaluate the working positions of those samples, a rapid entire body assessment (REBA method was used. Meanwhile, to observe the musculoskeletal disorders of those samples, a Nordic body map was used. Data obtained then were analyzed using Pearson correlation test with a significance level (p<0.05. Result: Results of data analysis using the Pearson correlation test showed that the significance value obtained was 0.036. It indicates that there was a correlation between the working positions and the lactic acid levels with the musculoskeletal disorders in those dentists. The results of the Pearson correlation test also revealed that there was a correlation between the working positions and the lactic acid levels among those dentists with a significance value of 0.025. Conclusion: It may be concluded that the wrong body positions during working can increase lactic acid level in the body of dentists. The increased level of lactic acid then can affect their muscles, leading to the high risk of

  14. Correlation between thromboelastography and traditional coagulation test parameters in hospitalized dogs

    Directory of Open Access Journals (Sweden)

    Rubanick JV

    2017-02-01

    Full Text Available Jean V Rubanick, Medora B Pashmakova, Micah A Bishop, James W Barr Department of Veterinary Small Animal Clinical Sciences, Texas A&M University, College Station, TX, USA Abstract: A hospital-based, prospective cross-sectional study was used to compare kaolin-activated thromboelastography (TEG parameters with traditional coagulation tests in 29 hospitalized dogs. Cases were included if the attending clinician requested coagulation testing. Blood was obtained from each dog and coagulation (prothrombin time, partial thromboplastin time, antithrombin activity, d-dimer concentration, and fibrinogen concentration and TEG analyses were performed. Hematocrit (Hct was also measured. Traditional coagulation results were evaluated for correlation with those from kaolin-activated TEG. Spearman’s correlation was used to calculate correlation coefficients. Fibrinogen was positively correlated with maximum amplitude (Pearson r=0.72, P<0.001 and global clot strength (Pearson r=0.72, P<0.001. There was no correlation between any of the remaining coagulation variables, TEG parameters, or Hct. Results of kaolin-activated TEG and traditional coagulation tests are not interchangeable means of monitoring coagulation derangements in this intensive care unit patient population. Determination of a true outcome measure is necessary to establish TEG’s clinical relevance to veterinary medicine. Keywords: TEG, thromboelastography, coagulation, hemostasis

  15. Correlation of prolonged QT interval and severity of cirrhosis of liver

    International Nuclear Information System (INIS)

    Tarique, S.; Sarwar, S.

    2011-01-01

    To determine correlation between prolonged QT interval and severity of disease in patients of cirrhosis of liver. Study Design: Descriptive cross sectional study. Patients and Methods: One hundred and seventeen patients of cirrhosis were included. Baseline haematological and biochemical parameters were determined. Model for end stage liver disease (MELD) score was determined for all patients to document stage of liver disease. Corrected QT interval was determined from electrocardiography of each patient using QT cirrhosis formula. Correlation between QT interval and MELD score was determined using Pearson correlation and Receiver Operating Characteristic (ROC) curve. Results: One hundred and seventeen included patients had mean age of 53.58 (+- 12.11) while male to female ratio was 1.78/1 (75 / 42). Mean MELD score was 17.08 (+- 6.54) in study patients varying between 6 and 37 while mean corrected QT interval was 0.44 seconds (+- 0.06). Pearson correlation revealed no significant relation between severity of liver disease as determined with MELD score and prolonged QT interval (p value 0.18) Area under curve with ROC curve for correlation between prolonged QT interval and severity of liver disease was 0.42. Conclusion: Prolonged QT interval is not an indicator of severity of disease in cirrhosis of liver. (author)

  16. Performance of Distributed CFAR Processors in Pearson Distributed Clutter

    Directory of Open Access Journals (Sweden)

    Messali Zoubeida

    2007-01-01

    Full Text Available This paper deals with the distributed constant false alarm rate (CFAR radar detection of targets embedded in heavy-tailed Pearson distributed clutter. In particular, we extend the results obtained for the cell averaging (CA, order statistics (OS, and censored mean level CMLD CFAR processors operating in positive alpha-stable (P&S random variables to more general situations, specifically to the presence of interfering targets and distributed CFAR detectors. The receiver operating characteristics of the greatest of (GO and the smallest of (SO CFAR processors are also determined. The performance characteristics of distributed systems are presented and compared in both homogeneous and in presence of interfering targets. We demonstrate, via simulation results, that the distributed systems when the clutter is modelled as positive alpha-stable distribution offer robustness properties against multiple target situations especially when using the "OR" fusion rule.

  17. Performance of Distributed CFAR Processors in Pearson Distributed Clutter

    Directory of Open Access Journals (Sweden)

    Faouzi Soltani

    2007-01-01

    Full Text Available This paper deals with the distributed constant false alarm rate (CFAR radar detection of targets embedded in heavy-tailed Pearson distributed clutter. In particular, we extend the results obtained for the cell averaging (CA, order statistics (OS, and censored mean level CMLD CFAR processors operating in positive alpha-stable (P&S random variables to more general situations, specifically to the presence of interfering targets and distributed CFAR detectors. The receiver operating characteristics of the greatest of (GO and the smallest of (SO CFAR processors are also determined. The performance characteristics of distributed systems are presented and compared in both homogeneous and in presence of interfering targets. We demonstrate, via simulation results, that the distributed systems when the clutter is modelled as positive alpha-stable distribution offer robustness properties against multiple target situations especially when using the “OR” fusion rule.

  18. Nursing Student Self-efficacy in Psychomotor Skills: Findings From a Validation, Longitudinal, and Correlational Study.

    Science.gov (United States)

    Bulfone, Giampiera; Fida, Roberta; Ghezzi, Valerio; Macale, Loreana; Sili, Alessandro; Alvaro, Rosaria; Palese, Alvisa

    Student perceptions of self-efficacy (SE) prevent stress and burnout and improve engagement in nursing education, thus increasing learning outcomes. The study aims were to (1) validate a scale measuring nursing SE in psychomotor skills (NSE-PS), (2) describe changes in NSE-PS over time, and (3) explore NSE-PS correlations with burnout and engagement. A total of 1117 nursing students participated. A significant increase in the NSE-PS scores over the years has emerged; in addition, all NSE-PS dimensions were correlated negatively with burnout and positively with engagement.

  19. Validation of a semi-quantitative food frequency questionnaire to assess food groups and nutrient intake.

    Science.gov (United States)

    Macedo-Ojeda, Gabriela; Vizmanos-Lamotte, Barbara; Márquez-Sandoval, Yolanda Fabiola; Rodríguez-Rocha, Norma Patricia; López-Uriarte, Patricia Josefina; Fernández-Ballart, Joan D

    2013-11-01

    Semi-quantitative Food Frequency Questionnaires (FFQs) analyze average food and nutrient intake over extended periods to associate habitual dietary intake with health problems and chronic diseases. A tool of this nature applicable to both women and men is not presently available in Mexico. To validate a FFQ for adult men and women. The study was conducted on 97 participants, 61% were women. Two FFQs were administered (with a one-year interval) to measure reproducibility. To assess validity, the second FFQ was compared against dietary record (DR) covering nine days. Statistical analyses included Pearson correlations and Intraclass Correlation Coefficients (ICC). The de-attenuation of the ICC resulting from intraindividual variability was controlled. The validity analysis was complemented by comparing the classification ability of FFQ to that of DR through concordance between intake categories and Bland-Altman plots. Reproducibility: ICC values for food groups ranged 0.42-0.87; the range for energy and nutrients was between 0.34 and 0.82. ICC values for food groups ranged 0.35-0.84; the range for energy and nutrients was between 0.36 and 0.77. Most subjects (56.7-76.3%) classified in the same or adjacent quintile for energy and nutrients using both methods. Extreme misclassification was <6.3% for all items. Bland-Altman plots reveal high concordance between FFQ and DR. FFQ produced sufficient levels of reproducibility and validity to determine average daily intake over one year. These results will enable the analysis of possible associations with chronic diseases and dietary diagnoses in adult populations of men and women. Copyright AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  20. Validation of a Smartphone Image-Based Dietary Assessment Method for Pregnant Women

    Directory of Open Access Journals (Sweden)

    Amy M. Ashman

    2017-01-01

    Full Text Available Image-based dietary records could lower participant burden associated with traditional prospective methods of dietary assessment. They have been used in children, adolescents and adults, but have not been evaluated in pregnant women. The current study evaluated relative validity of the DietBytes image-based dietary assessment method for assessing energy and nutrient intakes. Pregnant women collected image-based dietary records (via a smartphone application of all food, drinks and supplements consumed over three non-consecutive days. Intakes from the image-based method were compared to intakes collected from three 24-h recalls, taken on random days; once per week, in the weeks following the image-based record. Data were analyzed using nutrient analysis software. Agreement between methods was ascertained using Pearson correlations and Bland-Altman plots. Twenty-five women (27 recruited, one withdrew, one incomplete, median age 29 years, 15 primiparas, eight Aboriginal Australians, completed image-based records for analysis. Significant correlations between the two methods were observed for energy, macronutrients and fiber (r = 0.58–0.84, all p < 0.05, and for micronutrients both including (r = 0.47–0.94, all p < 0.05 and excluding (r = 0.40–0.85, all p < 0.05 supplements in the analysis. Bland-Altman plots confirmed acceptable agreement with no systematic bias. The DietBytes method demonstrated acceptable relative validity for assessment of nutrient intakes of pregnant women.

  1. Validation in Colombia of the Oswestry disability questionnaire in patients with low back pain.

    Science.gov (United States)

    Payares, Kelly; Lugo, Luz Helena; Morales, Victoria; Londoño, Alejandro

    2011-12-15

    Observational study to validate a scale. To translate, culturally adapt, and validate the Oswestry Disability Index (ODI), version 2.1a. The ODI is one of the most frequently used tools to evaluate disability in patients with low back pain. Its psychometric properties have shown to be highly reliable. Currently, no validated Colombian version is available. The ODI (2.1a) was translated into Spanish and this translated version was analyzed in terms of semantic and linguistic equivalence. Then, the Spanish version was translated back into English. The first time, the ODI was administered to a total of 111 patients with back pain. Internal consistency, construct validity, content validity and criterion validity were evaluated for the scale. The inter-rater reliability was evaluated by 2 different observers a day apart from each other and the intra-rater reliability was determined by the same observer, 7 days apart. A sensitivity-to-change analysis was performed on 81 patients. Of the sample, 67.6% were women, with a mean (SD) age of 44.88 (16.38) years. Cronbach alpha coefficient was 0.86. Inter-rater reliability yielded an intraclass correlation coefficient (ICC) of 0.94 whereas intrarater reliability yielded an ICC of 0.95. Pearson correlation between ODI and each of the 8 domains of SF-36, was statistically significant. Construct validity, when comparing extremely acute and chronic groups, did not show any differences (P = 0.409). Concurrent criterion validity between ODI and Roland-Morris Disability Questionnaire (RMQ) was r = 0.75; between ODI and the Visual Analog Scale (VAS) was r = 0.540. For patients who received an intervention, the value of this change was 1.2. ODI-C is a helpful, reliable and valid tool in Colombia for back pain patient follow-up and assessment, regardless the stage of the evolution. It is an observational study to validate the Oswestry disability index (ODI) in the Spanish language. ODI is the most used tool in evaluating disability

  2. The role of spurious correlation in the development of a komatiite alteration model

    Science.gov (United States)

    Butler, John C.

    1986-11-01

    Procedures for detecting alterations in komatiites are described. The research of Pearson (1897) on spurious correlation and of Chayes (1949, 1971) on ratio correlation is reviewed. The equations for the ratio correlation procedure are provided. The ratio correlation procedure is applied to the komatiites from Gorgona Island and the Barberton suite. Plots of the molecular proportion ratios of (FeO + MgO)/TiO2 versus SiO2/TiO2, and correlation coefficients for the komatiites are presented and analyzed.

  3. The Application of Canonical Correlation to Two-Dimensional Contingency Tables

    Directory of Open Access Journals (Sweden)

    Alberto F. Restori

    2010-03-01

    Full Text Available This paper re-introduces and demonstrates the use of Mickey’s (1970 canonical correlation method in analyzing large two-dimensional contingency tables. This method of analysis supplements the traditional analysis using the Pearson chi-square. Examples and a MATLAB source listing are provided.

  4. Feasibility and validity of accelerometer measurements to assess physical activity in toddlers

    Directory of Open Access Journals (Sweden)

    De Bourdeaudhuij Ilse

    2011-06-01

    Full Text Available Abstract Background Accelerometers are considered to be the most promising tool for measuring physical activity (PA in free-living young children. So far, no studies have examined the feasibility and validity of accelerometer measurements in children under 3 years of age. Therefore, the purpose of the present study was to examine the feasibility and validity of accelerometer measurements in toddlers (1- to 3-year olds. Methods Forty-seven toddlers (25 boys; 20 ± 4 months wore a GT1M ActiGraph accelerometer for 6 consecutive days and parental perceptions of the acceptability of wearing the monitor were assessed to examine feasibility. To investigate the validity of the ActiGraph and the predictive validity of three ActiGraph cut points, accelerometer measurements of 31 toddlers (17 boys; 20 ± 4 months during free play at child care were compared to directly observed PA, using the Observational System for Recording Physical Activity in Children-Preschool (OSRAC-P. Validity was assessed using Pearson and Spearman correlations and predictive validity using area under the Receiver Operating Characteristic curve (ROC-AUC. Results The feasibility examination indicated that accelerometer measurements of 30 toddlers (63.8% could be included with a mean registration time of 564 ± 62 min during weekdays and 595 ± 83 min during weekend days. According to the parental reports, 83% perceived wearing the accelerometer as 'not unpleasant and not pleasant' and none as 'unpleasant'. The validity evaluation showed that mean ActiGraph activity counts were significantly and positively associated with mean OSRAC-P activity intensity (r = 0.66; p Conclusions The present findings suggest that ActiGraph accelerometer measurements are feasible and valid for quantifying PA in toddlers. However, further research is needed to accurately identify PA intensities in toddlers using accelerometry.

  5. Effect of degree correlations above the first shell on the percolation transition

    OpenAIRE

    Valdez, L. D.; Buono, C.; Braunstein, L. A.; Macri, P. A.

    2011-01-01

    The use of degree-degree correlations to model realistic networks which are characterized by their Pearson's coefficient, has become widespread. However the effect on how different correlation algorithms produce different results on processes on top of them, has not yet been discussed. In this letter, using different correlation algorithms to generate assortative networks, we show that for very assortative networks the behavior of the main observables in percolation processes depends on the a...

  6. First experience from in-core sensor validation based on correlation and neuro-fuzzy techniques

    International Nuclear Information System (INIS)

    Figedy, S.

    2011-01-01

    In this work new types of nuclear reactor in-core sensor validation methods are outlined. The first one is based on combination of correlation coefficients and mutual information indices, which reflect the correlation of signals in linear and nonlinear regions. The method may be supplemented by wavelet transform based signal features extraction and pattern recognition by artificial neural networks and also fuzzy logic based decision making. The second one is based on neuro-fuzzy modeling of residuals between experimental values and their theoretical counterparts obtained from the reactor core simulator calculations. The first experience with this approach is described and further improvements to enhance the outcome reliability are proposed (Author)

  7. Validation of a Piezoelectric Sensor Array-Based Device for Measurement of Carotid-Femoral Pulse Wave Velocity: The Philips Prototype.

    Science.gov (United States)

    Xu, Shao-Kun; Hong, Xiang-Fei; Cheng, Yi-Bang; Liu, Chang-Yuan; Li, Yan; Yin, Bin; Wang, Ji-Guang

    2018-03-01

    Multiple piezoelectric pressure mechanotransducers topologized into an array might improve efficiency and accuracy in collecting arterial pressure waveforms for measurement of pulse wave velocity (PWV). In the present study, we validated a piezoelectric sensor array-based prototype (Philips) against the validated and clinically widely used Complior device (Alam Medical). We recruited 33 subjects with a wide distribution of PWV. For the validation, PWV was measured sequentially with the Complior device (four times) and the Philips prototype (three times). With the 99 paired PWV values, we investigated the agreement between the Philips prototype and the Complior device using Pearson correlation analysis and Bland-Altman plot. We also performed analysis on the determinants and reproducibility of PWV measured with both devices. The correlation coefficient for PWV measured with the two devices was 0.92 ( p prototype slightly overestimated PWV by 0.24 (± 2 standard deviations, ± 1.91) m/s, especially when PWV was high. The correlation coefficient between the difference and the average of the Philips and Complior measurements was 0.21 ( p = 0.035). Nonetheless, they had similar determinants. Age, mean arterial pressure, and sex altogether explained 81.6 and 83.9% of the variance of PWV values measured with the Philips prototype and Complior device, respectively. When the two extremes of the three PWV values measured with the Philips prototype and the Complior device were investigated, the coefficients of variation were 8.26 and 3.26%, respectively. Compared with the Complior device, the Philips prototype had similar accuracy, determinants, and reproducibility in measuring PWV.

  8. Translation and validation of a Spanish-language genetic health literacy screening tool.

    Science.gov (United States)

    Rodríguez, Sally Ann; Roter, Debra L; Castillo-Salgado, Carlos; Hooker, Gillian W; Erby, Lori H

    2015-02-01

    Literacy deficits and underutilization of medical services have been linked to health disparities among minorities, and this appears especially relevant for the Latino population. Given the increasing importance of genetics, assessment of genetic health literacy may direct future efforts to better serve this vulnerable population. The current study was designed to contribute to this area by translating and validating a Spanish-language genetic health literacy measure. This was a cross-sectional study involving an interviewer-administered questionnaire. Eligible individuals were Latinos between the ages of 18 and 75 residing in Maryland, who self-reported Spanish as their primary language, recruited through convenience sampling. The genetic health literacy measure components were adapted from existing English-language measures [Erby, Roter, Larson, & Cho's (2008) Rapid Estimate of Adult Literacy in Genetics (REAL-G) and Hooker et al.'s (2014) Genetic Literacy and Comprehension]. An existing Spanish-language general health literacy measure was used to establish preliminary concurrent validity [Lee, Bender, Ruiz, & Cho's (2006) SAHLSA]. 116 individuals completed the assessment. The Spanish-language REAL-G (REAL-G-Sp) was found to correlate well with the SAHLSA (Pearson's r = .77, p validity with an existing health literacy measure in the Latino population residing in Maryland. Significant proportions of this population are predicted to have limitations in genetic health literacy, even when information is provided in Spanish.

  9. Pulmonary Catherization Data Correlate Poorly with Renal Function in Heart Failure.

    Science.gov (United States)

    Masha, Luke; Stone, James; Stone, Danielle; Zhang, Jun; Sheng, Luo

    2018-04-10

    The mechanisms of renal dysfunction in heart failure are poorly understood. We chose to explore the relationship of cardiac filling pressures and cardiac index (CI) in relation to renal dysfunction in advanced heart failure. To determine the relationship between renal function and cardiac filling pressures using the United Network of Organ Sharing (UNOS) pulmonary artery catherization registry. Patients over the age of 18 years who were listed for single-organ heart transplantation were included. Exclusion criteria included a history of mechanical circulatory support, previous transplantation, any use of renal replacement therapy, prior history of malignancy, and cardiac surgery, amongst others. Correlations between serum creatinine (SCr) and CI, pulmonary capillary wedge pressure (PCWP), pulmonary artery systolic pressure (PASP), and pulmonary artery diastolic pressure (PADP) were assessed by Pearson correlation coefficients and simple linear regression coefficients. Pearson correlation coefficients between SCr and PCWP, PASP, and PADP were near zero with values of 0.1, 0.07, and 0.08, respectively (p < 0.0001). A weak negative correlation coefficient between SCr and CI was found (correlation coefficient, -0.045, p = 0.027). In a subgroup of young patients unlikely to have noncardiac etiologies, no significant correlations between these values were identified. These findings suggest that, as assessed by pulmonary artery catherization, none of the factors - PCWP, PASP, PADP, or CI - play a prominent role in cardiorenal syndromes. © 2018 S. Karger AG, Basel.

  10. The reliability and validity of radiographic measurements for determining the three-dimensional position of the talus in varus and valgus osteoarthritic ankles.

    Science.gov (United States)

    Nosewicz, Tomasz L; Knupp, Markus; Bolliger, Lilianna; Hintermann, Beat

    2012-12-01

    To assess the most accurate radiographic method to determine talar three-dimensional position in varus and valgus osteoarthritic ankles, we evaluated the reliability and validity of different radiographic measurements. Nine radiographic measurements were performed blindly on weight-bearing mortise, sagittal, and horizontal radiographs of 33 varus and 33 valgus feet (63 patients). Intra- and interobserver reliability was determined with the intraclass coefficient (ICC). Discriminant validity of measurements between varus and valgus feet was assessed with effect size (ES). Convergent validity (Pearson's r) was evaluated by correlating measurements to the dichotomized varus and valgus groups. Obtained measurements in both groups were finally compared with each other and with 30 control feet. Reliability was excellent (ICC > 0.80) in all but two measurements. Whereas frontal plane validity was excellent (ES and r > 0.80), horizontal and sagittal measurements showed poor to moderate validity (ES and r between 0.00 and 0.60). Four measurements were significantly different among all groups (p reliability, validity, and difference among the groups. The frontal tibiotalar surface angle, sagittal talocalcaneal inclination angle, and horizontal talometatarsal I angle accurately determine talar three-dimensional radiographic position in weight-bearing varus and valgus osteoarthritic ankles. Careful radiographic evaluation is important, as these deformities affect talar position in all three planes.

  11. Quality of life in head and neck cancer patients after surgical resection: translation into Cantonese and validation of the EORTC QLQ-H&N35.

    Science.gov (United States)

    Bower, W F; Vlantis, A C; Chung, T M L; Cheung, S K C; Bjordal, K; van Hasselt, C A

    2009-07-01

    High convergent and discriminant validity between subscales was achieved after the translation of EORTC QLQ-H&N35 into Cantonese. Most subscales were assessing distinct components of quality of life (QoL). The study aimed to translate the EORTC QLQ-H&N35 cancer module into Cantonese and to confirm validity and reliability for use in a Hong Kong head and neck (H&N) cancer population. An ethnocentric forward-backward translation of EORTC QLQ-H&N35 was conducted by bilingual head and neck health professionals. Discrepancies were identified and problematic wording and concepts revised. Further review preceded pilot testing in 119 postoperative H&N cancer patients. Internal consistency within each subscale, convergent and discriminant validity to check the item relevance and item representativeness within and between subscales were examined. Mean and standard deviations of each subscale and single item and Cronbach's alpha coefficients for subscales were calculated. Six of seven subscales achieved standard reliability (Cronbach's alpha coefficient >0.7). Correlation coefficients between an item and its own subscale were significantly higher than the coefficients with other subscales. Scaling success was found in all subscales. Pearson's correlation coefficient between subscales was social eating (r = 0.795), and speech problems and social contact (r = 0.754).

  12. Estudo da confiabilidade e validade da utilização do hidropletismômetro para medida de edema no tornozelo Study of the reliability and validity of the water plethysmographer for use in measurement of the edema at the ankle/foot

    Directory of Open Access Journals (Sweden)

    Ian Lara Lamounier Andrade

    2011-03-01

    measurements obtained by graduated cylinders from 10 to 1000 ml, water displacement device (gold standart. Intraclass correlation coefficients (ICCs evaluated intra- and inter-raters reliability, whereas paired Student t-tests and Pearson's correlation coefficients were used to establish validity of the water plethysmography.The results demonstrated excellent intra- and inter-rater reliability levels with levels with CCI3,1=0.99 and CCI3,2=0.99 respectively. No differences were found between the measures obtained with the water plethysmography compared to those of the water displacement device (p=0.40. Pearson's correlation coefficient showed a high magnitude and significance level between the measures (r=1,0; p<0.0001.The findings demonstrated that the water plethysmography is a reliable and valid instrument for measuring ankle/foot volume.

  13. Battery for ECT Related Cognitive Deficits (B4ECT-ReCoDe): development and validation.

    Science.gov (United States)

    Viswanath, Biju; Harihara, Shashidhara N; Nahar, Abhinav; Phutane, Vivek Haridas; Taksal, Aarati; Thirthalli, Jagadisha; Gangadhar, Bangalore N

    2013-06-01

    The use of electroconvulsive therapy (ECT) in treatment of psychiatric disorders is associated with adverse cognitive effects. There is a need to develop a short assessment tool of cognitive functions during the course of ECT. This study aimed at developing and validating a short, sensitive battery to assess cognitive deficits associated with ECT in India. Battery for ECT Related Cognitive Deficits (B4ECT-ReCoDe), a brief cognitive battery (20-30 min) to assess verbal, visual, working and autobiographic memory, sustained attention, psychomotor speed and subjective memory impairment, was administered to 30 in-patients receiving bilateral ECT, one day after the 1st, 3rd and 6th ECT. Data was analysed using repeated measures analysis of variance and Pearson's correlation. Significant deficits were found in verbal, visual and autobiographic memory, psychomotor speed. Subjective experience of memory loss correlated positively with verbal memory impairment. B4ECT-ReCoDe, a brief, sensitive measure of cognitive impairments associated with ECT can be used in routine clinical practice. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Standardized precipitation index based on pearson type III distribution Índice padronizado de precipitação baseado na distribuição pearson tipo III

    Directory of Open Access Journals (Sweden)

    Gabriel Constantino Blain

    2011-06-01

    Full Text Available The initial step in calculating the Standardized Precipitation Index (SPI is to determine a probability density function (pdf that describes the precipitation series under analysis. Once this pdf is determined, the cumulative probability of an observed precipitation amount is computed. The inverse normal function is then applied to the cumulative probability. The result is the SPI. This article assessed the changes in SPI final values, when computed based on Gamma 2-parameters (Gam and Pearson Type III (PE3 distributions (SPIGam and SPIPE3, respectively. Monthly rainfall series, available from five weather stations of the State of São Paulo, were chosen for this study. Considering quantitative and qualitative assessments of goodness-of-fit (evaluated at 1-, 3-, and 6-months precipitation totals, the PE3 distribution seems to be a better choice than the Gam distribution, in describing the long-term rainfall series of the State of São Paulo. In addition, it was observed that the number of SPI time series that could be seen as normally distributed was higher when this drought index was computed from the PE3 distribution. Thus, the use of the Pearson type III distribution within the calculation algorithm of the SPI is recommended in the State of São Paulo.O cálculo do Índice Padronizado de Precipitação (IPP inicia-se com a adoção de uma distribuição paramétrica (dp utilizada para a estimativa das probabilidades de ocorrência associadas a uma série de precipitação pluvial. Após essa escolha, a probabilidade acumulada de ocorrência de um determinado valor de precipitação é calculada. O IPP é obtido após a aplicação da função normal inversa a essa probabilidade acumulada. O artigo avaliou as alterações nos valores finais do IPP, quando calculado com base nas distribuições Gama com dois parâmetros (Gam e Pearson tipo III (PE3; IPPGam e IPPPE3, respectivamente. Utilizaram-se dados de precipitação pluvial de cinco

  15. On the optimal number of classes in the Pearson goodness-of-fit tests

    Czech Academy of Sciences Publication Activity Database

    Morales, D.; Pardo, L.; Vajda, Igor

    2005-01-01

    Roč. 41, č. 6 (2005), s. 677-698 ISSN 0023-5954 R&D Projects: GA AV ČR(CZ) IAA1075403 Grant - others:BFM(ES) 2003-00892; GV(ES) 04B-670 Institutional research plan: CEZ:AV0Z10750506 Keywords : pearson-type goodness -of- fit test s * asymptotic local test power * asymptotic equivalence of test s * optimal number of classes Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.343, year: 2005

  16. Psychometric properties and validation of Portuguese version of Ages & Stages Questionnaires (3rd edition): 9, 18 and 30 Questionnaires.

    Science.gov (United States)

    Lopes, Sónia; Graça, Patrícia; Teixeira, Salete; Serrano, Ana Maria; Squires, Jane

    2015-09-01

    The essential underlying foundations of Early Intervention (EI), in which parents/family play a critical role in their child's development, leads us to conclude that their contribution assessing early detection of problems is fundamental. The Ages & Stages Questionnaires (ASQ) is a standardized screening instrument that has been successfully studied in different countries and cultures. Translate and study the psychometrics proprieties of the Portuguese version of the 9, 18 and 30month questionnaires of the Ages and Stages Questionnaires, 3rd edition (ASQ-3). Cross-sectional study. Validity and reliability were studied in a sample of 234 parents of children within 9, 18 and 30months. The results indicated that the questionnaires had good internal consistency, strong agreement between observers and between observations with two weeks interval, and strong Pearson product-moment correlation coefficients between the overall and the total for each domain. The cutoff points (i.e. 2 standard deviations below the mean domain score), that identifies children who should receive further referral for more comprehensive assessment, were close to those determined in the original ASQ-3 psychometric studies. Cronbach's alpha ranging from .42 to .70 and Pearson's r values varies from .22 to .60. Although some weaknesses were noted in psychometric qualities analysis, it can be concluded that the ASQ-PT of 9, 18 and 30months of age fulfills the requirements of a screening tool validated for the Portuguese population. To allow the early identification of children with developmental problems. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Validity and reproducibility of the Physical Activity Scale for the Elderly (PASE) questionnaire for the measurement of the physical activity level in patients after total knee arthroplasty.

    Science.gov (United States)

    Bolszak, Sylvain; Casartelli, Nicola C; Impellizzeri, Franco M; Maffiuletti, Nicola A

    2014-02-20

    The need for valid and reproducible questionnaires to routinely assess the physical activity level of patients after total knee arthroplasty (TKA) is of particular concern in clinical settings. Aims of this study were to evaluate the validity and reproducibility of the physical activity scale for the elderly (PASE) questionnaire in TKA patients, with a particular view on gender differences. A total of 50 elderly patients (25 women and 25 men aged 70 ± 6 years) following primary unilateral TKA were recruited. The reproducibility was evaluated by administering the PASE questionnaire during two occasions separated by 7 days. The construct (criterion) validity was investigated by comparing the physical activity level reported by patients in the PASE questionnaire to that measured by accelerometry. Reproducibility was evaluated using intraclass correlation coefficients (ICC3,1) for reliability and standard error of measurement (SEM) and smallest detectable change (SDC) for agreement, while validity was investigated with Pearson correlation coefficients. Reliability of the PASE total score was acceptable for men (ICC = 0.77) but not for women (ICC = 0.58). Its agreement was low for both men and women, as witnessed by high SEM (32% and 35%, respectively) and SDC (89% and 97%, respectively). Construct validity of the PASE total score was low in both men (r = 0.45) and women (r = 0.06). The PASE questionnaire has several validity and reproducibility shortcomings, therefore its use is not recommended for the assessment of physical activity level in patients after TKA, particularly in women.

  18. Psychometric validation study of the liebowitz social anxiety scale - self-reported version for Brazilian Portuguese.

    Directory of Open Access Journals (Sweden)

    Larissa Forni dos Santos

    Full Text Available Social Anxiety Disorder (SAD is prevalent and rarely diagnosed due to the difficulty in recognizing its symptoms as belonging to a disorder. Therefore, the evaluation/screening scales are of great importance for its detection, with the most used being the Liebowitz Social Anxiety Scale (LSAS. Thus, this study proposed to evaluate the psychometric properties of internal consistency and convergent validity, as well as the confirmatory factorial analysis and reliability of the self-reported version of the LSAS (LSAS-SR, translated into Brazilian Portuguese, in a sample of the general population (N = 413 and in a SAD clinical sample (N = 252. The convergent validity with specific scales for the evaluation of SAD and a general anxiety scale presented correlations ranging from 0.21 to 0.84. The confirmatory factorial analysis did not replicate the previously indicated findings of the literature, with the difficulty being in obtaining a consensus factorial structure common to the diverse cultures in which the instrument was studied. The LSAS-SR presented excellent internal consistency (α = 0.90-0.96 and test-retest reliability (Intraclass Correlation Coefficient = 0.81; Pearson's = 0.82. The present findings support those of international studies that attest to the excellent psychometric properties of the LSAS-SR, endorsing its status as the gold standard.

  19. The ageing males' symptoms scale for Chinese men: reliability,validation and applicability of the Chinese version.

    Science.gov (United States)

    Kong, X-b; Guan, H-t; Li, H-g; Zhou, Y; Xiong, C-l

    2014-11-01

    In this study, the ageing males' symptoms (AMS) scale was translated into Chinese following methodological recommendations for linguistic and cultural adaptation. This study aimed to confirm the reliability, validation and applicability of the simplified Chinese version of the scale (CN-AMS) in older Chinese men, a free health screening for men older than 40 years was conducted. All participants completed a health questionnaire, which consisted of personal health information, AMS scale, the generic quality of life (QoL) instrument SF36 and the Beck Depression Inventory (BDI). The fasting blood samples of participants were collected on the day of completing the health questionnaire. Serum total testosterone (TT), albumin and sex hormone-binding globulin levels were measured and the level of free testosterone was calculated (calculated free testosterone, CFT). A total of 244 men (mean age: 52 ± 7.3 years, range: 40-79 years) were involved in the investigation and provided informed consent before their participation. The reliability of CN-AMS was analysed as internal consistency reliability (Cronbach's alpha was 0.91) as well as a 4-week-interval test-retest stability (Pearson's correlation was 0.83) and found to be good. The validation of CN-AMS was analysed as the internal structure analysis (Pearson's correlation between total score and each item score r = 0.48-0.75), total-domain-correlation (among the three domains r = 0.47-0.68, p < 0.01; domains with the total score r = 0.81-0.88, p < 0.01), and cross-validation with other scales (with SF36 r = -0.59, p < 0.01; with BDI r = 0.50, p < 0.01). Androgen deficiency (AD) was defined as the presence of three sexual symptoms (decreased frequency of morning erections, sexual thoughts and erectile dysfunction) in combination with TT < 11 nmol/L and CFT < 220 pmol/L, and the sensitivity and specificity for CN-AMS was 68.8 and 6.8% respectively. The CN-AMS had sufficient sensitivity in

  20. The Malay Version of the Perceived Stress Scale (PSS)-10 is a Reliable and Valid Measure for Stress among Nurses in Malaysia.

    Science.gov (United States)

    Sandhu, Sukhvinder Singh; Ismail, Noor Hassim; Rampal, Krishna Gopal

    2015-11-01

    The Perceived Stress Scale-10 (PSS-10) is widely used to assess stress perception. The aim of this study was to translate the original PSS-10 into Malay and assess the reliability and validity of the Malay version among nurses. The Malay version of the PSS-10 was distributed among 229 nurses from four government hospitals in Selangor State. Test-retest reliability and concurrent validity was conducted with 25 nurses with the Malay version of the Depression Anxiety Stress Scales (DASS) 21. Cronbach's alpha, confirmatory factor analysis (CFA), intraclass correlation coefficient and Pearson's r correlation coefficient were used to determine the psychometric properties of the Malay PSS-10. Two factor components were yielded through exploratory factor analysis with eigenvalues of 3.37 and 2.10, respectively. Both of the factors accounted for 54.6% of the variance. CFA yielded a two-factor structure with satisfactory goodness-of-fit indices [x 2 /df = 2.43; comparative fit index (CFI) = 0.92, goodness-of-fit Index (GFI) = 0.94; standardised root mean square residual (SRMR) = 0.07 and root mean square error of approximation (RMSEA) = 0.08 (90% CI = 0.07-0.09)]. The Cronbach's alpha coefficient for the total items was 0.63 (0.82 for factor 1 and 0.72 for factor 2). The intraclass correlation coefficient (ICC) was 0.81 (95% CI: 0.62-0.91) for test-retest reliability testing after seven days. The total score and the negative component of the PSS-10 correlated significantly with the stress component of the DASS-21: (r = 0.61, P < 0.001) and (r = 0.56, P < 0.004), respectively. The Malay version of the PSS-10 demonstrated a satisfactory level of validity and reliability to assess stress perception. Therefore, this questionnaire is valid in assessing stress perception among nurses in Malaysia.

  1. Validity and reliability of Thai version of the Foot and Ankle Outcome Score in patients with arthritis of the foot and ankle.

    Science.gov (United States)

    Angthong, Chayanin

    2016-12-01

    Although the Foot and Ankle Outcome Score (FAOS) is commonly used in several languages for a variety of foot disorders, it has not been validated specifically for foot and ankle arthritic conditions. The aims of the present study were to translate the original English FAOS into Thai and to evaluate the validity and reliability of the Thai version of the FAOS for the foot and ankle arthritic conditions. The original FAOS was translated into Thai using forward-backward translation. The Thai FAOS and validated Thai Short Form-36 (SF-36 ® ) questionnaires were distributed to 44 Thai patients suffering from arthritis of the foot and ankle to complete. For validation, Thai FAOS scores were correlated with SF-36 scores. Test-retest reliability and internal consistency were also analyzed in this study. The Thai FAOS score demonstrated sufficient correlation with SF-36 total score in Pain (Pearson's correlation coefficient (r)=0.45, p=0.002), Symptoms (r=0.45, p=0.002), Activities of Daily Living (ADL) (r=0.47, p=0.001), and Quality of Life (QOL) (r=0.38, p=0.011) subscales. The Sports and Recreational Activities (Sports & Rec) subscale did not correlate significantly with the SF-36 ® (r=0.20, p=0.20). Cronbach's alpha, a measure of internal consistency, for the five subscales was as follows: Pain, 0.94 (pvalidity for the evaluation of foot and ankle arthritis. Although reliability was satisfactory for the major subscale ADL, it was not sufficient for the minor subscales. Our findings suggest that it can be used as a disease-specific instrument to evaluate foot and ankle arthritis and can complement other reliable outcome surveys. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  2. Validation of an instrument to assess evidence-based practice knowledge, attitudes, access, and confidence in the dental environment.

    Science.gov (United States)

    Hendricson, William D; Rugh, John D; Hatch, John P; Stark, Debra L; Deahl, Thomas; Wallmann, Elizabeth R

    2011-02-01

    and residents demonstrated statistically significant changes, in desired directions, from pre- to post-test. For the student test-retest, Pearson correlations for KACE scales were as follows: knowledge 0.66, attitudes 0.66, accessing evidence 0.74, and confidence 0.76. For the knowledge scale test-retest by faculty members, the Pearson correlation was 0.79. The construct validity of the KACE is equivalent to that of instruments that assess similar EBP dimensions in medicine. Item consistency for the knowledge scale was more variable than for other KACE scales, a finding also reported for medically oriented EBP instruments. We conclude that the KACE has good discriminative validity, responsiveness to training effects, and test-retest reliability.

  3. Personality disorders in substance abusers: Validation of the DIP-Q through principal components factor analysis and canonical correlation analysis

    Directory of Open Access Journals (Sweden)

    Hesse Morten

    2005-05-01

    Full Text Available Abstract Background Personality disorders are common in substance abusers. Self-report questionnaires that can aid in the assessment of personality disorders are commonly used in assessment, but are rarely validated. Methods The Danish DIP-Q as a measure of co-morbid personality disorders in substance abusers was validated through principal components factor analysis and canonical correlation analysis. A 4 components structure was constructed based on 238 protocols, representing antagonism, neuroticism, introversion and conscientiousness. The structure was compared with (a a 4-factor solution from the DIP-Q in a sample of Swedish drug and alcohol abusers (N = 133, and (b a consensus 4-components solution based on a meta-analysis of published correlation matrices of dimensional personality disorder scales. Results It was found that the 4-factor model of personality was congruent across the Danish and Swedish samples, and showed good congruence with the consensus model. A canonical correlation analysis was conducted on a subset of the Danish sample with staff ratings of pathology. Three factors that correlated highly between the two variable sets were found. These variables were highly similar to the three first factors from the principal components analysis, antagonism, neuroticism and introversion. Conclusion The findings support the validity of the DIP-Q as a measure of DSM-IV personality disorders in substance abusers.

  4. Reliability and validity of adapted Turkish Version of Scoliosis Research Society-22 (SRS-22) questionnaire.

    Science.gov (United States)

    Alanay, Ahmet; Cil, Akin; Berk, Haluk; Acaroglu, R Emre; Yazici, Muharrem; Akcali, Omer; Kosay, Can; Genc, Yasemin; Surat, Adil

    2005-11-01

    Outcome study to determine the internal consistency, and validity of adapted Turkish version of Scoliosis Research Society-22 (SRS-22) Instrument. To evaluate the validity and reliability of adapted Turkish Version of SRS-22 questionnaire. The SRS-22 questionnaire is a widely accepted questionnaire to assess the health-related quality of life for scoliotic patients in the United States. However, its adaptation in languages other than the source language is necessary for its multinational use. Translation/retranslation of the English version of the SRS-22 was done, and all steps for cross-cultural adaptation process were performed properly by an expert committee. Later, SRS-22 questionnaires and previously validated Short Form-36 (SF-36) outcome instruments were mailed to 82 patients who had been surgically treated for idiopathic scoliosis. All patients had a minimum of 2 years follow-up. Fifty-four patients (66%) responded to the first set of questionnaires. Forty-seven of the first time respondents returned their second survey. The average age of the 47 patients (12 male, 35 female) was 19.8 years (range, 14-31 years). The two measures of reliability as internal consistency and reproducibility were determined by Cronbach alpha statistics and intraclass correlation coefficient, respectively. Concurrent validity was measured by comparing with an already validated questionnaire (SF-36). Measurement was made using the Pearson correlation coefficient (r). The study demonstrated satisfactory internal consistency with high Cronbach alpha values for the four of the corresponding domains (pain, 0.72; self-image, 0.80; mental health, 0.72; and satisfaction, 0.83). However, the Cronbach alpha value for function/activity domain (0.48) was considerably lower than the original questionnaire. The intraclass correlation coefficient for the same domains was 0.80, 0.82, 0.78, 0.81, and 0.76, respectively, demonstrating a satisfactory test/retest reproducibility. Considering

  5. Validity of the Aboriginal children's health and well-being measure: Aaniish Naa Gegii?

    Science.gov (United States)

    Young, Nancy L; Wabano, Mary Jo; Usuba, Koyo; Pangowish, Brenda; Trottier, Mélanie; Jacko, Diane; Burke, Tricia A; Corbiere, Rita G

    2015-09-17

    Aboriginal children experience challenges to their health and well-being, yet also have unique strengths. It has been difficult to accurately assess their health outcomes due to the lack of culturally relevant measures. The Aboriginal Children's Health and Well-Being Measure (ACHWM) was developed to address this gap. This paper describes the validity of the new measure. We recruited First Nations children from one First Nation reserve in Canada. Participants were asked to complete the ACHWM independently using a computer tablet. Participants also completed the PedsQL. The ACHWM total score and 4 Quadrant scores were expected to have a moderate correlation of between 0.4 and 0.6 with the parallel PedsQL total score, domains (scale scores), and summary scores. Paired ACHWM and PedsQL scores were available for 48 participants. They had a mean age of 14.6 (range of 7 to 19) years and 60.4 % were girls. The Pearson's correlation between the total ACHWM score and a total PedsQL aggregate score was 0.52 (p = 0.0001). The correlations with the Physical Health Summary Scores and the Psychosocial Health Summary Scores were slightly lower range (r = 0.35 p = 0.016; and r = 0.51 p = 0.0002 respectively) and approached the expected range. The ACHWM Quadrant scores were moderately correlated with the parallel PedsQL domains ranging from r = 0.45 to r = 0.64 (p ≤ 0.001). The Spiritual Quadrant of the ACHWM did not have a parallel domain in the PedsQL. These results establish the validity of the ACHWM. The children gave this measure an Ojibway name, Aaniish Naa Gegii, meaning "how are you?". This measure is now ready for implementation, and will contribute to a better understanding of the health of Aboriginal children.

  6. Neuro-QoL health-related quality of life measurement system: Validation in Parkinson's disease.

    Science.gov (United States)

    Nowinski, Cindy J; Siderowf, Andrew; Simuni, Tanya; Wortman, Catherine; Moy, Claudia; Cella, David

    2016-05-01

    Neuro-QoL is a multidimensional patient-reported outcome measurement system assessing aspects of physical, mental, and social health identified by neurology patients and caregivers as important. One of the first neurology-specific patient-reported outcome measure systems created using modern test development methods, Neuro-Qol enables brief, yet precise, assessment and the ability to conduct both PD-specific and cross-disease comparisons. We present results of Neuro-QoL clinical validation using a sample of PD patients. A total of 120 PD patients recruited from academic medical centers were assessed at baseline, 1 week, and 6 months. Assessments included Neuro-QoL and general and PD-specific validity measures. Participants were 62% male and 95% white (average age = 66); H & Y stages were 1 (16%), 2 (61%), 3 (18%), and 4 (5%). Internal consistency and test-retest reliability of Neuro-QoL ranged from Cronbach's alphas = 0.81 to 0.94 with intraclass correlation coefficients = 0.66 to 0.80. Pearson's correlations between Neuro-QoL and legacy measures were generally moderate and in expected directions. UPDRS Part 2 was moderately correlated with Neuro-QoL Upper Extremity and Mobility, respectively (r's = -0.44; -0.59). Parkinson's Disease Questionnaire-39 and Neuro-QoL measures of similar constructs showed strong-to-moderate correlations (r's = 0.70-0.44). Neuro-QoL measures of fatigue, mobility, positive emotion, and emotional/behavioral control showed responsiveness to self-reported change. Neuro-QoL is valid for use in PD clinical research. Reliability for all but two measures is sufficient for group comparisons, with some evidence supporting responsiveness to change. Neuro-QoL possesses characteristics, such as brevity, flexibility in administration, and suitability, for cross-disease comparisons that may be advantageous to users in a variety of settings. © 2016 Movement Disorder Society. © 2016 International Parkinson and Movement Disorder

  7. Initial Validation for the Estimation of Resting-State fMRI Effective Connectivity by a Generalization of the Correlation Approach

    Directory of Open Access Journals (Sweden)

    Nan Xu

    2017-05-01

    Full Text Available Resting-state functional MRI (rs-fMRI is widely used to noninvasively study human brain networks. Network functional connectivity is often estimated by calculating the timeseries correlation between blood-oxygen-level dependent (BOLD signal from different regions of interest (ROIs. However, standard correlation cannot characterize the direction of information flow between regions. In this paper, we introduce and test a new concept, prediction correlation, to estimate effective connectivity in functional brain networks from rs-fMRI. In this approach, the correlation between two BOLD signals is replaced by a correlation between one BOLD signal and a prediction of this signal via a causal system driven by another BOLD signal. Three validations are described: (1 Prediction correlation performed well on simulated data where the ground truth was known, and outperformed four other methods. (2 On simulated data designed to display the “common driver” problem, prediction correlation did not introduce false connections between non-interacting driven ROIs. (3 On experimental data, prediction correlation recovered the previously identified network organization of human brain. Prediction correlation scales well to work with hundreds of ROIs, enabling it to assess whole brain interregional connectivity at the single subject level. These results provide an initial validation that prediction correlation can capture the direction of information flow and estimate the duration of extended temporal delays in information flow between regions of interest ROIs based on BOLD signal. This approach not only maintains the high sensitivity to network connectivity provided by the correlation analysis, but also performs well in the estimation of causal information flow in the brain.

  8. Validation of the EQ-5D in a general population sample in urban China.

    Science.gov (United States)

    Wang, Hong-Mei; Patrick, Donald L; Edwards, Todd C; Skalicky, Anne M; Zeng, Hai-Yan; Gu, Wen-Wen

    2012-02-01

    To evaluate the reliability and validity of the EQ-5D in a general population sample in urban China. Thousand and eight hundred respondents in 18 communities of Hangzhou, China were recruited by multi-stage stratified random sampling. Respondents self-administered a questionnaire including the EQ-5D, the SF-36, and demographic questions. Test-retest reliability at 2-week intervals was evaluated using Kappa coefficient, the intraclass correlation coefficient. The standard error of measurement (SEM) was used to indicate the absolute measurement error. Construct validity was established using convergent, discriminant, and known groups analyses. Complete data for all EQ-5D dimensions were available for 1,747 respondents (97%). Kappa values were from 0.35 to 1.0. The ICCs of test-retest reliability were 0.53 for the EQ-5D index score and 0.87 for the EQ VAS score. The SEM values were 0.13 (9.22% range) and 4.20 (4.20% range) for the EQ-5D index and EQ VAS scores, respectively. The Pearson's correlation coefficients between the EQ-5D and the SF-36 were stronger between comparable dimensions than those between less comparable dimensions, demonstrating convergent and discriminant evidence of construct validity. The Chinese EQ-5D distinguished well between known groups: respondents who reported poor general health and chronic diseases had worse HRQoL than those without. Older people, females, people widowed or divorced, and those with a lower socioeconomic status reported poorer HRQoL. Respondents reporting no problems on any EQ-5D dimension had better scores on the SF-36 summary scores than those reporting problems. The Chinese version of the EQ-5D demonstrated acceptable construct validity and fair to moderate levels of test-retest reliability in an urban general population in China.

  9. Cone-beam computed tomography for lung cancer - validation with CT and monitoring tumour response during chemo-radiation therapy.

    Science.gov (United States)

    Michienzi, Alissa; Kron, Tomas; Callahan, Jason; Plumridge, Nikki; Ball, David; Everitt, Sarah

    2017-04-01

    Cone-beam computed tomography (CBCT) is a valuable image-guidance tool in radiation therapy (RT). This study was initiated to assess the accuracy of CBCT for quantifying non-small cell lung cancer (NSCLC) tumour volumes compared to the anatomical 'gold standard', CT. Tumour regression or progression on CBCT was also analysed. Patients with Stage I-III NSCLC, prescribed 60 Gy in 30 fractions RT with concurrent platinum-based chemotherapy, routine CBCT and enrolled in a prospective study of serial PET/CT (baseline, weeks two and four) were eligible. Time-matched CBCT and CT gross tumour volumes (GTVs) were manually delineated by a single observer on MIM software, and were analysed descriptively and using Pearson's correlation coefficient (r) and linear regression (R 2 ). Of 94 CT/CBCT pairs, 30 patients were eligible for inclusion. The mean (± SD) CT GTV vs CBCT GTV on the four time-matched pairs were 95 (±182) vs 98.8 (±160.3), 73.6 (±132.4) vs 70.7 (±96.6), 54.7 (±92.9) vs 61.0 (±98.8) and 61.3 (±53.3) vs 62.1 (±47.9) respectively. Pearson's correlation coefficient (r) was 0.98 (95% CI 0.97-0.99, ρ < 0.001). The mean (±SD) CT/CBCT Dice's similarity coefficient was 0.66 (±0.16). Of 289 CBCT scans, tumours in 27 (90%) patients regressed by a mean (±SD) rate of 1.5% (±0.75) per fraction. The mean (±SD) GTV regression was 43.1% (±23.1) from the first to final CBCT. Primary lung tumour volumes observed on CBCT and time-matched CT are highly correlated (although not identical), thereby validating observations of GTV regression on CBCT in NSCLC. © 2016 The Royal Australian and New Zealand College of Radiologists.

  10. [Diagnostic value and functional correlations of the ADAS-Cog scale in Alzheimer's disease: data on NORMACODEM project].

    Science.gov (United States)

    Monllau, A; Pena-Casanova, J; Blesa, R; Aguilar, M; Bohm, P; Sol, J M; Hernandez, G

    2007-10-01

    The aims of this study were to assess the criterion validity of Alzheimer's Disease Assessment Scale (ADAS) and its cognitive subscale (ADAS-Cog) for the diagnosis of Alzheimer's disease (AD), and to determine their different cut-off scores and sensitivity and specificity values. In addition, we also attempted to study the possible correlations between cognitive scores (ADAS) and functional measures. 451 subjects were studied (254 controls, 86 subjects with mild cognitive impairment and 111 patients with AD). ADAS total score was obtained by adding the cognitive (ADAS-Cog) and non-cognitive (ADAS-Nocog) scales. Scores were adjusted for age and formal education. For assessing the possible correlation between cognitive and functional measures, the following instruments were administered: Rapid Disability Rating Scale-2 (RDRS-2), Blessed Dementia Rating Scale (BDRS) and the Interview for the Deterioration of Daily Living in Dementia (IDDD). ROC curves and Pearson correlation coefficient. ADAS best cut-off score for dementia was > or = 17 providing sensitivity and specificity values of 90.09% and 85.88 % respectively, while for the ADAS-Cog best cut-off score was > or = 12 with sensitivity and specificity values of 89.19 % and 88.53 % respectively. In both cases scores were adjusted for age and formal education. The area under the ROC curve was 0.95 and 0.94 respectively. Highly significant correlations were found for ADAS and 19 ADAS-Cog with the functional scales studied. Both, ADAS and ADAS-Cog report good validity in terms of sensitivity, specificity and as predictive value for AD. Moreover, significant correlations were found between the functional impairment observed in patients with AD and the overall scores achieved in the ADAS and ADAS-Cog.

  11. Validity of an ankle joint motion and position sense measurement system and its application in healthy subjects and patients with ankle sprain.

    Science.gov (United States)

    Lin, Chueh-Ho; Chiang, Shang-Lin; Lu, Liang-Hsuan; Wei, Shun-Hwa; Sung, Wen-Hsu

    2016-07-01

    Ankle motion and proprioception in multiple axis movements are crucial for daily activities. However, few studies have developed and used a multiple axis system for measuring ankle motion and proprioception. This study was designed to validate a novel ankle haptic interface system that measures the ankle range of motion (ROM) and joint position sense in multiple plane movements, investigating the proprioception deficits during joint position sense tasks for patients with ankle instability. Eleven healthy adults (mean ± standard deviation; age, 24.7 ± 1.9 years) and thirteen patients with ankle instability were recruited in this study. All subjects were asked to perform tests to evaluate the validity of the ankle ROM measurements and underwent tests for validating the joint position sense measurements conducted during multiple axis movements of the ankle joint. Pearson correlation was used for validating the angular position measurements obtained using the developed system; the independent t test was used to investigate the differences in joint position sense task performance for people with or without ankle instability. The ROM measurements of the device were linearly correlated with the criterion standards (r = 0.99). The ankle instability and healthy groups were significantly different in direction, absolute, and variable errors of plantar flexion, dorsiflexion, inversion, and eversion (p ankle joint motion and position sense measurement system is valid and can be used for measuring the ankle ROM and joint position sense in multiple planes and indicate proprioception deficits for people with ankle instability. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Validation of HOMA-IR in a model of insulin-resistance induced by a high-fat diet in Wistar rats.

    Science.gov (United States)

    Antunes, Luciana C; Elkfury, Jessica L; Jornada, Manoela N; Foletto, Kelly C; Bertoluci, Marcello C

    2016-04-01

    Objective The present study aimed to validate homeostasis model assessment of insulin resistance (HOMA-IR) in relation to the insulin tolerance test (ITT) in a model of insulin-resistance in Wistar rats induced by a 19-week high-fat diet. Materials and methods A total of 30 male Wistar rats weighing 200-300 g were allocated into a high-fat diet group (HFD) (55% fat-enriched chow, ad lib, n = 15) and a standard-diet group (CD) standard chow, ad lib, n = 15), for 19 weeks. ITT was determined at baseline and in the 19th week. HOMA-IR was determined between the 18-19th week in three different days and the mean was considered for analysis. Area under the curve (AUC-ITT) of the blood glucose excursion along 120 minutes after intra-peritoneal insulin injection was determined and correlated with the corresponding fasting values for HOMA-IR. Results AUC-ITT and HOMA-IR were significantly greater after 19th week in HFD compared to CD (p HOMA-IR was strongly correlated (Pearson's) with AUC-ITT r = 0.637; p HOMA-IR and AUC-ITT showed similar sensitivity and specificity. Conclusion HOMA-IR is a valid measure to determine insulin-resistance in Wistar rats. Arch Endocrinol Metab. 2016;60(2):138-42.

  13. Validation and reliability of a modified sphygmomanometer for the assessment of handgrip strength in Parkinson´s disease

    Directory of Open Access Journals (Sweden)

    Soraia M. Silva

    2015-04-01

    Full Text Available BACKGROUND: Handgrip strength is currently considered a predictor of overall muscle strength and functional capacity. Therefore, it is important to find reliable and affordable instruments for this analysis, such as the modified sphygmomanometer test (MST. OBJECTIVES: To assess the concurrent criterion validity of the MST, to compare the MST with the Jamar dynamometer, and to analyze the reproducibility (i.e. reliability and agreement of the MST in individuals with Parkinson's disease (PD. METHOD: The authors recruited 50 subjects, 24 with PD (65.5±6.2 years of age and 26 healthy elderly subjects (63.4±7.2 years of age. The handgrip strength was measured using the Jamar dynamometer and modified sphygmomanometer. The concurrent criterion validity was analyzed using Pearson's correlation coefficient and a simple linear regression test. The reproducibility of the MST was evaluated with the coefficient of intra-class correlation (ICC2,1, the standard error of measurement (SEM, the minimal detectable change (MDC, and the Bland-Altman plot. For all of the analyses, α≤0.05 was considered a risk. RESULTS: There was a significant correlation of moderate magnitude (r≥0.45 between the MST and the Jamar dynamometer. The MST had excellent reliability (ICC2,1≥0.7. The SEM and the MDC were adequate; however, the Bland-Altman plot indicated an unsatisfactory interrater agreement. CONCLUSIONS: The MST exhibited adequate validity and excellent reliability and is, therefore, suitable for monitoring the handgrip strength in PD. However, if the goal is to compare the measurements between examiners, the authors recommend that the data be interpreted with caution.

  14. Mitochondrial DNA deletion in a patient with combined features of Leigh and Pearson syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Blok, R.B.; Thorburn, D.R.; Danks, D.M. [Royal Children`s Hospital, Melbourne (Australia)] [and others

    1994-09-01

    We describe a heteroplasmic 4237 bp mitochondrial DNA (mtDNA) deletion in an 11 year old girl who has suffered from progressive illness since birth. She has some features of Leigh syndrome (global developmental delay with regression, brainstem dysfunction and lactic acidosis), together with other features suggestive of Pearson syndrome (history of pancytopenia and failure to thrive). The deletion was present at a level greater than 50% in skeletal muscle, but barely detectable in skin fibroblasts following Southern blot analysis, and only observed in blood following PCR analysis. The deletion spanned nt 9498 to nt 13734, and was flanked by a 12 bp direct repeat. Genes for cytochrome c oxidase subunit III, NADH dehydrogenase subunits 3, 4L, 4 and 5, and tRNAs for glycine, arginine, histidine, serine({sup AGY}) and leucine({sup CUN}) were deleted. Southern blotting also revealed an altered Apa I restriction site which was shown by sequence analysis to be caused by G{r_arrow}A nucleotide substitution at nt 1462 in the 12S rRNA gene. This was presumed to be a polymorphism. No abnormalities of mitochondrial ultrastructure, distribution or of respiratory chain enzyme complexes I-IV in skeletal muscle were observed. Mitochondrial disorders with clinical features overlapping more than one syndrome have been reported previously. This case further demonstrates the difficulty in correlating observed clinical features with a specific mitochondrial DNA mutation.

  15. Exponential smoothing weighted correlations

    Science.gov (United States)

    Pozzi, F.; Di Matteo, T.; Aste, T.

    2012-06-01

    In many practical applications, correlation matrices might be affected by the "curse of dimensionality" and by an excessive sensitiveness to outliers and remote observations. These shortcomings can cause problems of statistical robustness especially accentuated when a system of dynamic correlations over a running window is concerned. These drawbacks can be partially mitigated by assigning a structure of weights to observational events. In this paper, we discuss Pearson's ρ and Kendall's τ correlation matrices, weighted with an exponential smoothing, computed on moving windows using a data-set of daily returns for 300 NYSE highly capitalized companies in the period between 2001 and 2003. Criteria for jointly determining optimal weights together with the optimal length of the running window are proposed. We find that the exponential smoothing can provide more robust and reliable dynamic measures and we discuss that a careful choice of the parameters can reduce the autocorrelation of dynamic correlations whilst keeping significance and robustness of the measure. Weighted correlations are found to be smoother and recovering faster from market turbulence than their unweighted counterparts, helping also to discriminate more effectively genuine from spurious correlations.

  16. Real external predictivity of QSAR models: how to evaluate it? Comparison of different validation criteria and proposal of using the concordance correlation coefficient.

    Science.gov (United States)

    Chirico, Nicola; Gramatica, Paola

    2011-09-26

    The main utility of QSAR models is their ability to predict activities/properties for new chemicals, and this external prediction ability is evaluated by means of various validation criteria. As a measure for such evaluation the OECD guidelines have proposed the predictive squared correlation coefficient Q(2)(F1) (Shi et al.). However, other validation criteria have been proposed by other authors: the Golbraikh-Tropsha method, r(2)(m) (Roy), Q(2)(F2) (Schüürmann et al.), Q(2)(F3) (Consonni et al.). In QSAR studies these measures are usually in accordance, though this is not always the case, thus doubts can arise when contradictory results are obtained. It is likely that none of the aforementioned criteria is the best in every situation, so a comparative study using simulated data sets is proposed here, using threshold values suggested by the proponents or those widely used in QSAR modeling. In addition, a different and simple external validation measure, the concordance correlation coefficient (CCC), is proposed and compared with other criteria. Huge data sets were used to study the general behavior of validation measures, and the concordance correlation coefficient was shown to be the most restrictive. On using simulated data sets of a more realistic size, it was found that CCC was broadly in agreement, about 96% of the time, with other validation measures in accepting models as predictive, and in almost all the examples it was the most precautionary. The proposed concordance correlation coefficient also works well on real data sets, where it seems to be more stable, and helps in making decisions when the validation measures are in conflict. Since it is conceptually simple, and given its stability and restrictiveness, we propose the concordance correlation coefficient as a complementary, or alternative, more prudent measure of a QSAR model to be externally predictive.

  17. The Category Cued Recall test in very mild Alzheimer's disease: discriminative validity and correlation with semantic memory functions.

    Science.gov (United States)

    Vogel, A; Mortensen, E L; Gade, A; Waldemar, G

    2007-01-01

    Episodic memory tests that measure cued recall may be particularly effective in the diagnosis of early Alzheimer's disease (AD) because they examine both episodic and semantic memory functions. The Category Cued Recall (CCR) test provides superordinate semantic cues at encoding and retrieval, and high discriminative validity has been claimed for this test. The aim of this study was to investigate the discriminative validity for this test when compared with the 10-word memory list from Alzheimer's Disease Assessment Scale (ADAS-cog) that measures free recall. The clinical diagnosis of AD was taken as the standard. It was also investigated whether the two episodic memory tests correlated with measures of semantic memory. The tests were administered to 35 patients with very mild AD (Mini Mental State Examination score >22) and 28 control subjects. Both tests had high sensitivity (>88%) with high specificity (>89%). One out of the five semantic memory tests was significantly correlated to performances on CCR, whereas delayed recall on the ADAS-cog memory test was significantly correlated to two semantic tests. In conclusion, the discriminative validity of the CCR test and the ADAS-cog memory test was equivalent in very mild AD. This may be because CCR did not tap more semantic processes, which are impaired in the earliest phases of AD, than a test of free recall.

  18. Two new meal- and web-based interactive food frequency questionnaires: validation of energy and macronutrient intake.

    Science.gov (United States)

    Christensen, Sara E; Möller, Elisabeth; Bonn, Stephanie E; Ploner, Alexander; Wright, Antony; Sjölander, Arvid; Bälter, Olle; Lissner, Lauren; Bälter, Katarina

    2013-06-05

    Meal-Q and its shorter version, MiniMeal-Q, are 2 new Web-based food frequency questionnaires. Their meal-based and interactive format was designed to promote ease of use and to minimize answering time, desirable improvements in large epidemiological studies. We evaluated the validity of energy and macronutrient intake assessed with Meal-Q and MiniMeal-Q as well as the reproducibility of Meal-Q. Healthy volunteers aged 20-63 years recruited from Stockholm County filled out the 174-item Meal-Q. The questionnaire was compared to 7-day weighed food records (WFR; n=163), for energy and macronutrient intake, and to doubly labeled water (DLW; n=39), for total energy expenditure. In addition, the 126-item MiniMeal-Q was evaluated in a simulated validation using truncated Meal-Q data. We also assessed the answering time and ease of use of both questionnaires. Bland-Altman plots showed a varying bias within the intake range for all validity comparisons. Cross-classification of quartiles placed 70%-86% in the same/adjacent quartile with WFR and 77% with DLW. Deattenuated and energy-adjusted Pearson correlation coefficients with the WFR ranged from r=0.33-0.74 for macronutrients and was r=0.18 for energy. Correlations with DLW were r=0.42 for Meal-Q and r=0.38 for MiniMeal-Q. Intraclass correlations for Meal-Q ranged from r=0.57-0.90. Median answering time was 17 minutes for Meal-Q and 7 minutes for MiniMeal-Q, and participants rated both questionnaires as easy to use. Meal-Q and MiniMeal-Q are easy to use and have short answering times. The ranking agreement is good for most of the nutrients for both questionnaires and Meal-Q shows fair reproducibility.

  19. Cone-beam computed tomography for lung cancer – validation with CT and monitoring tumour response during chemo-radiation therapy

    International Nuclear Information System (INIS)

    Michienzi, Alissa; Kron, Tomas; Callahan, Jason; Plumridge, Nikki; Ball, David; Everitt, Sarah

    2017-01-01

    Cone-beam computed tomography (CBCT) is a valuable image-guidance tool in radiation therapy (RT). This study was initiated to assess the accuracy of CBCT for quantifying non-small cell lung cancer (NSCLC) tumour volumes compared to the anatomical ‘gold standard’, CT. Tumour regression or progression on CBCT was also analysed. Patients with Stage I-III NSCLC, prescribed 60 Gy in 30 fractions RT with concurrent platinum-based chemotherapy, routine CBCT and enrolled in a prospective study of serial PET/CT (baseline, weeks two and four) were eligible. Time-matched CBCT and CT gross tumour volumes (GTVs) were manually delineated by a single observer on MIM software, and were analysed descriptively and using Pearson's correlation coefficient (r) and linear regression (R 2 ). Of 94 CT/CBCT pairs, 30 patients were eligible for inclusion. The mean (± SD) CT GTV vs CBCT GTV on the four time-matched pairs were 95 (±182) vs 98.8 (±160.3), 73.6 (±132.4) vs 70.7 (±96.6), 54.7 (±92.9) vs 61.0 (±98.8) and 61.3 (±53.3) vs 62.1 (±47.9) respectively. Pearson's correlation coefficient (r) was 0.98 (95% CI 0.97–0.99, ρ < 0.001). The mean (±SD) CT/CBCT Dice's similarity coefficient was 0.66 (±0.16). Of 289 CBCT scans, tumours in 27 (90%) patients regressed by a mean (±SD) rate of 1.5% (±0.75) per fraction. The mean (±SD) GTV regression was 43.1% (±23.1) from the first to final CBCT. Primary lung tumour volumes observed on CBCT and time-matched CT are highly correlated (although not identical), thereby validating observations of GTV regression on CBCT in NSCLC.

  20. Reproducibility and relative validity of a food frequency questionnaire developed for adults in Taizhou, China.

    Directory of Open Access Journals (Sweden)

    Maoqiang Zhuang

    Full Text Available To evaluate the reproducibility and validity of a food frequency questionnaire (FFQ developed to investigate the relationship between dietary factors and diseases in the adult Chinese population in East China.A total of 78 males and 129 females aged 30-75 years completed four inconsecutive 24-hour dietary recalls (24-HRs, served as a reference method and two FFQs (FFQ1 and FFQ2 over a nine-month interval. The reproducibility of the FFQ was estimated with correlation coefficients, cross-classification, and weighted kappa statistic. The validity was assessed by comparing the data obtained from FFQ and 24-HRs.The median nutrient intakes assessed with FFQs were higher than the average of four 24-HRs. For the food groups, Spearman, Pearson, and intraclass correlation coefficients between FFQ1 and FFQ2 ranged from 0.23 to 0.61, 0.27 to 0.64, and 0.26 to 0.65, respectively. For total energy and nutrient intakes, the corresponding coefficients ranged from 0.25 to 0.61, 0.28 to 0.64, and 0.28 to 0.62, respectively. The correlations between FFQ1 and FFQ2 for most nutrients decreased after adjustment with total energy intake. More than 70% of the subjects were classified into the same and adjacent categories by both FFQs. For food groups, the crude, energy-adjusted, and de-attenuated Spearman correlation coefficients between FFQ2 and the 24-HRs ranged from 0.17 to 0.59, 0.10 to 0.57, and 0.11 to 0.64, respectively. For total energy and nutrient intakes, the corresponding coefficients ranged from 0.20 to 0.58, 0.08 to 0.54, and 0.09 to 0.56, respectively. More than 67% of the subjects were classified into the same and adjacent categories by both instruments. Both weighted kappa statistic and Bland-Altman Plots showed reasonably acceptable agreement between the FFQ2 and 24-HRs.The FFQ developed for adults in the Taizhou area is reasonably reliable and valid for assessment of most food and nutrient intakes.

  1. Validity and reliability of a nutrition knowledge survey for assessment in elementary school children.

    Science.gov (United States)

    Gower, Jared R; Moyer-Mileur, Laurie J; Wilkinson, Robert D; Slater, Hillarie; Jordan, Kristine C

    2010-03-01

    Limited surveys are available to assess the nutrition knowledge of children. The goals of this study were to test the validity and reliability of a computer nutrition knowledge survey for elementary school students and to evaluate the impact of the "Fit Kids 'r' Healthy Kids" nutrition intervention via the knowledge survey. During survey development, a sample (n=12) of health educators, elementary school teachers, and registered dietitians assessed the survey. The target population consisted of first- through fourth-grade students from Salt Lake City, UT, metropolitan area schools. Participants were divided into reliability (n=68), intervention (n=74), and control groups (n=59). The reliability group took the survey twice (2 weeks apart); the intervention and control groups also took the survey twice, but at pre- and post-intervention (4 weeks later). Only students from the intervention group participated in four weekly nutrition classes. Reliability was assessed by Pearson's correlation coefficients for knowledge scores. Results demonstrated appropriate content validity, as indicated by expert peer ratings. Test-retest reliability correlations were found to be significant for the overall survey (r=0.54; PNutrition knowledge was assessed upon program completion with paired samples t tests. Students from the intervention group demonstrated improvement in nutrition knowledge (12.2+/-1.9 to 13.5+/-1.6; Pnutrition survey demonstrated content validity and test-retest reliability for first- through fourth-grade elementary school children. Also, the study results imply that the Fit Kids 'r' Healthy Kids intervention promoted gains in nutrition knowledge. Overall, the computer survey shows promise as an appealing medium for assessing nutrition knowledge in children. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  2. Triple collocation-based estimation of spatially correlated observation error covariance in remote sensing soil moisture data assimilation

    Science.gov (United States)

    Wu, Kai; Shu, Hong; Nie, Lei; Jiao, Zhenhang

    2018-01-01

    Spatially correlated errors are typically ignored in data assimilation, thus degenerating the observation error covariance R to a diagonal matrix. We argue that a nondiagonal R carries more observation information making assimilation results more accurate. A method, denoted TC_Cov, was proposed for soil moisture data assimilation to estimate spatially correlated observation error covariance based on triple collocation (TC). Assimilation experiments were carried out to test the performance of TC_Cov. AMSR-E soil moisture was assimilated with a diagonal R matrix computed using the TC and assimilated using a nondiagonal R matrix, as estimated by proposed TC_Cov. The ensemble Kalman filter was considered as the assimilation method. Our assimilation results were validated against climate change initiative data and ground-based soil moisture measurements using the Pearson correlation coefficient and unbiased root mean square difference metrics. These experiments confirmed that deterioration of diagonal R assimilation results occurred when model simulation is more accurate than observation data. Furthermore, nondiagonal R achieved higher correlation coefficient and lower ubRMSD values over diagonal R in experiments and demonstrated the effectiveness of TC_Cov to estimate richly structuralized R in data assimilation. In sum, compared with diagonal R, nondiagonal R may relieve the detrimental effects of assimilation when simulated model results outperform observation data.

  3. Validity of the RAST for evaluating anaerobic power performance as compared to Wingate test in cycling athletes

    Directory of Open Access Journals (Sweden)

    Marcos Roberto Queiroga

    2013-12-01

    Full Text Available The validity of the Running-based Anaerobic Sprint Test (RAST was investigated to evaluate the anaerobic power performance in comparison to Wingate test in cycling athletes. Ten mountain-bike male cyclists (28.0±7.3 years randomly performed Wingate Test and RAST with two trials each. After several anthropometric measurements, peak power (PP, mean power (MP and fatigue index (FI for RAST and Wingate Test were analyzed using Student's paired t-test, Pearson's linear correlation test (r and Bland and Altman's plots. Results showed that, with the exception of FI (33.8±4.6% vs. 37.8±7.9%; r=0.172, significant differences were detected between the Wingate and RAST tests with regard to PP and MP. Although there was a strong correlation for PP and MP, or rather, 0.831 and 0.714 respectively, agreement of analysis between Wingate and RAST protocols was low. The above suggested that RAST was not appropriate to evaluate the performance of anaerobic power by Wingate test in cycling athletes.

  4. Quantifying meta-correlations in financial markets

    Science.gov (United States)

    Kenett, Dror Y.; Preis, Tobias; Gur-Gershgoren, Gitit; Ben-Jacob, Eshel

    2012-08-01

    Financial markets are modular multi-level systems, in which the relationships between the individual components are not constant in time. Sudden changes in these relationships significantly affect the stability of the entire system, and vice versa. Our analysis is based on historical daily closing prices of the 30 components of the Dow Jones Industrial Average (DJIA) from March 15th, 1939 until December 31st, 2010. We quantify the correlation among these components by determining Pearson correlation coefficients, to investigate whether mean correlation of the entire portfolio can be used as a precursor for changes in the index return. To this end, we quantify the meta-correlation - the correlation of mean correlation and index return. We find that changes in index returns are significantly correlated with changes in mean correlation. Furthermore, we study the relationship between the index return and correlation volatility - the standard deviation of correlations for a given time interval. This parameter provides further evidence of the effect of the index on market correlations and their fluctuations. Our empirical findings provide new information and quantification of the index leverage effect, and have implications to risk management, portfolio optimization, and to the increased stability of financial markets.

  5. Quantifying frontal plane knee motion during single limb squats: reliability and validity of 2-dimensional measures.

    Science.gov (United States)

    Gwynne, Craig R; Curran, Sarah A

    2014-12-01

    Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.

  6. The Persian Checklist of Pleasant Events (PCPE: ‎Development, Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Sepideh Bakht

    2015-12-01

    frequency, ‎pleasantness and total scores ‎and age of the participants ‎‎(Pearson correlation coefficient, r ‎‎= -.194, p<0.05; r = -.270, p<0.01 ‎& r = -.234, p<0.05, respectively.‎Conclusion‏:‏‎ PCPE as an ‎assessment tool has shown to ‎have good reliability and validity ‎among Iranians. Further steps ‎should be taken to validate this ‎instrument in different ‎psychopathologies such as ‎depression, addiction and ‎obesity.

  7. Fast-GPU-PCC: A GPU-Based Technique to Compute Pairwise Pearson's Correlation Coefficients for Time Series Data-fMRI Study.

    Science.gov (United States)

    Eslami, Taban; Saeed, Fahad

    2018-04-20

    Functional magnetic resonance imaging (fMRI) is a non-invasive brain imaging technique, which has been regularly used for studying brain’s functional activities in the past few years. A very well-used measure for capturing functional associations in brain is Pearson’s correlation coefficient. Pearson’s correlation is widely used for constructing functional network and studying dynamic functional connectivity of the brain. These are useful measures for understanding the effects of brain disorders on connectivities among brain regions. The fMRI scanners produce huge number of voxels and using traditional central processing unit (CPU)-based techniques for computing pairwise correlations is very time consuming especially when large number of subjects are being studied. In this paper, we propose a graphics processing unit (GPU)-based algorithm called Fast-GPU-PCC for computing pairwise Pearson’s correlation coefficient. Based on the symmetric property of Pearson’s correlation, this approach returns N ( N − 1 ) / 2 correlation coefficients located at strictly upper triangle part of the correlation matrix. Storing correlations in a one-dimensional array with the order as proposed in this paper is useful for further usage. Our experiments on real and synthetic fMRI data for different number of voxels and varying length of time series show that the proposed approach outperformed state of the art GPU-based techniques as well as the sequential CPU-based versions. We show that Fast-GPU-PCC runs 62 times faster than CPU-based version and about 2 to 3 times faster than two other state of the art GPU-based methods.

  8. Asymmetric correlation matrices: an analysis of financial data

    Science.gov (United States)

    Livan, G.; Rebecchi, L.

    2012-06-01

    We analyse the spectral properties of correlation matrices between distinct statistical systems. Such matrices are intrinsically non-symmetric, and lend themselves to extend the spectral analyses usually performed on standard Pearson correlation matrices to the realm of complex eigenvalues. We employ some recent random matrix theory results on the average eigenvalue density of this type of matrix to distinguish between noise and non-trivial correlation structures, and we focus on financial data as a case study. Namely, we employ daily prices of stocks belonging to the American and British stock exchanges, and look for the emergence of correlations between two such markets in the eigenvalue spectrum of their non-symmetric correlation matrix. We find several non trivial results when considering time-lagged correlations over short lags, and we corroborate our findings by additionally studying the asymmetric correlation matrix of the principal components of our datasets.

  9. Four broad temperament dimensions: Description, convergent validation correlations, and comparison with the Big Five

    Directory of Open Access Journals (Sweden)

    Helen eFisher

    2015-08-01

    Full Text Available A new temperament construct based on recent brain physiology literature has been investigated using the Fisher Temperament Inventory (FTI. Four collections of behaviors emerged, each associated with a specific neural system: the dopamine, serotonin, testosterone and estrogen/oxytocin system. These four temperament suites have been designated: 1 Curious/Energetic, 2 Cautious/Social Norm Compliant, 3 Analytical/Tough-minded, and 4 Prosocial/Empathetic temperament dimensions. Two functional magnetic resonance imaging (fMRI studies have suggested that the FTI can measure the influence of these neural systems. In this paper, to further the behavioral validation and characterization of the four proposed temperament dimensions, we measured correlations with five variables: 1 gender; 2 level of education; 3 religious preference; 4 political orientation; 5 the degree to which an individual regards sex as essential to a successful relationship. Subjects were 39,913 anonymous members of a US Internet dating site and 70,000+ members in six other countries. Correlations with the five variables characterize the Fisher Temperament Inventory and are consistent with mechanisms using the proposed neuromodulators. We also report on an analysis between the FTI and the NEO-Five Factor Inventory, using a college sample (n=215, which showed convergent validity. The results provide novel correlates not available in other questionnaires: religiosity, political orientation and attitudes about sex in a relationship. Also, an Eigen analysis replicated the four clusters of co-varying items. The FTI, with its broad systems and non-pathologic factors complements existing personality questionnaires. It provides an index of some brain systems that contribute to temperament, and may be useful in psychotherapy, business, medicine, and the legal community.

  10. Evaluation of the Validity and Reliability of the Chinese Healthy Eating Index

    Directory of Open Access Journals (Sweden)

    Ya-Qun Yuan

    2018-01-01

    Full Text Available The Chinese Healthy Eating Index (CHEI is a measuring instrument of diet quality in accordance with the Dietary Guidelines for Chinese (DGC-2016. The objective of the study was to evaluate the validity and reliability of the CHEI. Data from 12,473 adults from the China Health and Nutrition Survey (CHNS-2011, including 3-day–24-h dietary recalls were used in this study. The CHEI was assessed by four exemplary menus developed by the DGC-2016, the general linear models, the independent t-test and the Mann–Whitney U-test, the Spearman’s correlation analysis, the principal components analysis (PCA, the Cronbach’s coefficient, and the Pearson correlation with nutrient intakes. A higher CHEI score was linked with lower exposure to known risk factors of Chinese diets. The CHEI scored nearly perfect for exemplary menus for adult men (99.8, adult women (99.7, and the healthy elderly (99.1, but not for young children (91.2. The CHEI was able to distinguish the difference in diet quality between smokers and non-smokers (P < 0.0001, people with higher and lower education levels (P < 0.0001, and people living in urban and rural areas (P < 0.0001. Low correlations with energy intake for the CHEI total and component scores (|r| < 0.34, P < 0.01 supported the index assessed diet quality independently of diet quantity. The PCA indicated that underlying multiple dimensions compose the CHEI, and Cronbach’s coefficient α was 0.22. Components of dairy, fruits and cooking oils had the greatest impact on the total score. People with a higher CHEI score had not only a higher absolute intake of nutrients (P < 0.001, but also a more nutrient-dense diet (P < 0.001. Our findings support the validity and reliability of the CHEI when using the 3-day–24-h recalls.

  11. Validity of the Elite HRV Smartphone Application for Examining Heart Rate Variability in a Field-Based Setting.

    Science.gov (United States)

    Perrotta, Andrew S; Jeklin, Andrew T; Hives, Ben A; Meanwell, Leah E; Warburton, Darren E R

    2017-08-01

    Perrotta, AS, Jeklin, AT, Hives, BA, Meanwell, LE, and Warburton, DER. Validity of the elite HRV smartphone application for examining heart rate variability in a field-based setting. J Strength Cond Res 31(8): 2296-2302, 2017-The introduction of smartphone applications has allowed athletes and practitioners to record and store R-R intervals on smartphones for immediate heart rate variability (HRV) analysis. This user-friendly option should be validated in the effort to provide practitioners confidence when monitoring their athletes before implementing such equipment. The objective of this investigation was to examine the relationship and validity between a vagal-related HRV index, rMSSD, when derived from a smartphone application accessible with most operating systems against a frequently used computer software program, Kubios HRV 2.2. R-R intervals were recorded immediately upon awakening over 14 consecutive days using the Elite HRV smartphone application. R-R recordings were then exported into Kubios HRV 2.2 for analysis. The relationship and levels of agreement between rMSSDln derived from Elite HRV and Kubios HRV 2.2 was examined using a Pearson product-moment correlation and a Bland-Altman Plot. An extremely large relationship was identified (r = 0.92; p smartphone HRV application may offer a reliable platform when assessing parasympathetic modulation.

  12. Concurrent Validity of Two Standardized Measures of Gross Motor Function in Young Children with Autism Spectrum Disorder.

    Science.gov (United States)

    Holloway, Jamie M; Long, Toby; Biasini, Fred

    2018-04-02

    This study provides information on how two standardized measures based on different theoretical frameworks can be used in collecting information on motor development and performance in 4- and 5-year-olds with autism spectrum disorder (ASD). The purpose of the study was to determine the concurrent validity of the Miller Function and Participation Scales (M-FUN) with the Peabody Developmental Motor Scales, Second Edition (PDMS-2) in young children with ASD. The gross motor sections of the PDMS-2 and the M-FUN were administered to 22 children with ASD between the ages of 48 and 71 months. Concurrent validity between overall motor scores and agreement in identification of motor delay were assessed. A very strong correlation (Pearson's r =.851) was found between the M-FUN scale scores and the PDMS-2 gross motor quotients (GMQs). Strong agreement in identification of children with average motor skills and delayed motor skills at 1.5 standard deviations below the mean was also found. This study supports the concurrent validity of the M-FUN with the PDMS-2 for young children with ASD. While both tests provide information regarding motor delay, the M-FUN may provide additional information regarding the neurological profile of the child.

  13. Development and validation of a semi-quantitative food frequency questionnaire to assess dietary intake in Turkish adults.

    Science.gov (United States)

    Gunes, Fatma Esra; Imeryuz, Nese; Akalin, Arzu; Bekiroglu, Nural; Alphan, Emel; Oguz, Aytekin; Dehghan, Mahshid

    2015-07-01

    To validate the original food frequency questionnaire in Turkish adult population. The cross-sectional study was conducted in June and December 2008 and 2009, and comprised adults of either gender aged 30-70 years. All subjects were Caucasians and were native Turkish speakers. The food frequency questionnaire containing 229 most frequently consumed foods under 7 topics was used for data collection. It was completed twice and the 24-hour dietary recall four times in a year. In order to assess the validity of the questionnaire, Pearson correlation, attenuation coefficient, measures of agreement between the two methods, weighted kappa statistics and Bland-Altman plots were employed. SPSS 16 was used for statistical analysis. Of the 120 subjects in the study, 71(59%) were males and 49(41%) were females with an overall mean age of 50.16±9.76 years. The correlation of estimated nutrient intake between the food frequency questionnaire and 24-hour dietary recall varied between 0.200 and 0.468, energy-adjusted regression was between 0.044 and 0.611 and attenuation coefficients of regression were between 0.339 and 0.658 for the selected macro and micro nutrients. Bland-Altman plots showed an acceptable agreement between the two methods. When nutrient intake was categorised in quartiles, proportions of the same or adjacent quartiles were 98.3%, 98.4%, 98.3%, 96.7% and 95% for energy, fat, protein, carbohydrates and fibre, respectively. The first food frequency questionnaire developed in Turkish language was an adequate and valid tool to assess the nutritional habits of the local population.

  14. Validation Study of the Korean Version of the Brief Clinical Form of the Neuropsychiatric Inventory

    Directory of Open Access Journals (Sweden)

    Hee-Jin Kim

    2016-06-01

    Full Text Available Aim: This study aims to provide a brief questionnaire form of the Neuropsychiatric Inventory (NPI-Q in Korean translated from the original NPI-Q that is intended for the evaluation of behavioral and psychological symptoms of dementia in routine clinical practice. Patients and Methods: We developed a Korean version of the NPI-Q (KNPI-Q and compared subitems with those of the Korean version of the NPI (KNPI in 63 dementia patients; 47 patients had been diagnosed with Alzheimer's disease with dementia, 8 with vascular dementia, and 8 with dementia with Lewy body disease. The diagnosis was based on the National Institute of Neurological and Communicative Disorders and Stroke - Alzheimer's Disease and Related Disorders Association criteria for possible and probable Alzheimer's disease and the International Statistical Classification of Diseases and Related Health Problems, 10th revision, criteria for vascular dementia and other dementing diseases. All patients received the Korean version of the Mini-Mental State Examination and the Clinical Dementia Rating within 1 month of the KNPI-Q. Results: Test-retest reliability of the KNPI-Q using a Pearson correlation index was r = 0.89 for the total symptom scale and r = 0.90 for the distress scale. The prevalence of analogous symptom ratings differed by less than 6.7%. Convergent validity between the KNPI-Q and the NPI using a Pearson correlation index was r = 0.879 for the total symptom scale and r = 0.92 for the distress scale. Conclusions: The KNPI-Q is a reliable and brief instrument that can be employed for screening in the evaluation of neuropsychiatric symptoms of dementia and associated caregiver distress. It may be suitable for use in general clinical practice and could be administered as a brief neuropsychiatric interview.

  15. The validity and reliability of the my jump 2 app for measuring the reactive strength index and drop jump performance.

    Science.gov (United States)

    Haynes, Tom; Bishop, Chris; Antrobus, Mark; Brazier, Jon

    2018-03-27

    This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app's ability to measure the reactive strength index (RSI). Fourteen male sport science students (age: 29.5 ± 9.9 years) performed three drop jumps from 20 cm and 40 cm (totalling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation (CV) and BlandAltman plots. Near perfect agreement was seen between devices at 20 cm for RSI (ICC = 0.95) and contact time (ICC = 0.99) and at 40 cm for RSI (ICC = 0.98), jump height (ICC = 0.96) and contact time (ICC = 0.92); with very strong agreement seen at 20 cm for jump height (ICC = 0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r = 0.94; 40 cm; r = 0.97), jump height (20 cm: r = 0.80; 40 cm; r = 0.96) and contact time (20 cm = 0.96; 40 cm; r = 0.98). The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.

  16. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    Science.gov (United States)

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability

  17. Crowdsourcing: a valid alternative to expert evaluation of robotic surgery skills.

    Science.gov (United States)

    Polin, Michael R; Siddiqui, Nazema Y; Comstock, Bryan A; Hesham, Helai; Brown, Casey; Lendvay, Thomas S; Martino, Martin A

    2016-11-01

    Robotic-assisted gynecologic surgery is common, but requires unique training. A validated assessment tool for evaluating trainees' robotic surgery skills is Robotic-Objective Structured Assessments of Technical Skills. We sought to assess whether crowdsourcing can be used as an alternative to expert surgical evaluators in scoring Robotic-Objective Structured Assessments of Technical Skills. The Robotic Training Network produced the Robotic-Objective Structured Assessments of Technical Skills, which evaluate trainees across 5 dry lab robotic surgical drills. Robotic-Objective Structured Assessments of Technical Skills were previously validated in a study of 105 participants, where dry lab surgical drills were recorded, de-identified, and scored by 3 expert surgeons using the Robotic-Objective Structured Assessments of Technical Skills checklist. Our methods-comparison study uses these previously obtained recordings and expert surgeon scores. Mean scores per participant from each drill were separated into quartiles. Crowdworkers were trained and calibrated on Robotic-Objective Structured Assessments of Technical Skills scoring using a representative recording of a skilled and novice surgeon. Following this, 3 recordings from each scoring quartile for each drill were randomly selected. Crowdworkers evaluated the randomly selected recordings using Robotic-Objective Structured Assessments of Technical Skills. Linear mixed effects models were used to derive mean crowdsourced ratings for each drill. Pearson correlation coefficients were calculated to assess the correlation between crowdsourced and expert surgeons' ratings. In all, 448 crowdworkers reviewed videos from 60 dry lab drills, and completed a total of 2517 Robotic-Objective Structured Assessments of Technical Skills assessments within 16 hours. Crowdsourced Robotic-Objective Structured Assessments of Technical Skills ratings were highly correlated with expert surgeon ratings across each of the 5 dry lab drills

  18. Validity and Reliability of the Verbal Numerical Rating Scale for Children Aged 4 to 17 Years With Acute Pain.

    Science.gov (United States)

    Tsze, Daniel S; von Baeyer, Carl L; Pahalyants, Vartan; Dayan, Peter S

    2018-06-01

    The Verbal Numerical Rating Scale is the most commonly used self-report measure of pain intensity. It is unclear how the validity and reliability of the scale scores vary across children's ages. We aimed to determine the validity and reliability of the scale for children presenting to the emergency department across a comprehensive spectrum of age. This was a cross-sectional study of children aged 4 to 17 years. Children self-reported their pain intensity, using the Verbal Numerical Rating Scale and Faces Pain Scale-Revised at 2 serial assessments. We evaluated convergent validity (strong validity defined as correlation coefficient ≥0.60), agreement (difference between concurrent Verbal Numerical Rating Scale and Faces Pain Scale-Revised scores), known-groups validity (difference in score between children with painful versus nonpainful conditions), responsivity (decrease in score after analgesic administration), and reliability (test-retest at 2 serial assessments) in the total sample and subgroups based on age. We enrolled 760 children; 27 did not understand the Verbal Numerical Rating Scale and were removed. Of the remainder, Pearson correlations were strong to very strong (0.62 to 0.96) in all years of age except 4 and 5 years, and agreement was strong for children aged 8 and older. Known-groups validity and responsivity were strong in all years of age. Reliability was strong in all age subgroups, including each year of age from 4 to 7 years. Convergent validity, known-groups validity, responsivity, and reliability of the Verbal Numerical Rating Scale were strong for children aged 6 to 17 years. Convergent validity was not strong for children aged 4 and 5 years. Our findings support the use of the Verbal Numerical Rating Scale for most children aged 6 years and older, but not for those aged 4 and 5 years. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  19. Career Anchors: Understanding Differences Among Demographic Groups at the Naval Postgraduate School

    National Research Council Canada - National Science Library

    Shin, Hannah

    2001-01-01

    .... A web-based survey of 34 items was taken by a sample of 130 students. Cronbach's coefficient alpha, Pearson's correlation, and factor analyses were used to estimate the convergent and discriminant validity of the scales...

  20. Validation of sleep-2-Peak: A smartphone application that can detect fatigue-related changes in reaction times during sleep deprivation.

    Science.gov (United States)

    Brunet, Jean-François; Dagenais, Dominique; Therrien, Marc; Gartenberg, Daniel; Forest, Geneviève

    2017-08-01

    Despite its high sensitivity and validity in the context of sleep loss, the Psychomotor Vigilance Test (PVT) could be improved. The aim of the present study was to validate a new smartphone PVT-type application called sleep-2-Peak (s2P) by determining its ability to assess fatigue-related changes in alertness in a context of extended wakefulness. Short 3-min versions of s2P and of the classic PVT were administered at every even hour during a 35-h total sleep deprivation protocol. In addition, subjective measures of sleepiness were collected. The outcomes on these tests were then compared using Pearson product-moment correlations, t tests, and repeated measures within-groups analyses of variance. The results showed that both tests significantly correlated on all outcome variables, that both significantly distinguished between the alert and sleepy states in the same individual, and that both varied similarly through the sleep deprivation protocol as sleep loss accumulated. All outcome variables on both tests also correlated significantly with the subjective measures of sleepiness. These results suggest that a 3-min version of s2P is a valid tool for differentiating alert from sleepy states and is as sensitive as the PVT for tracking fatigue-related changes during extended wakefulness and sleep loss. Unlike the PVT, s2P does not provide feedback to subjects on each trial. We discuss how this feature of s2P raises the possibility that the performance results measured by s2P could be less impacted by motivational confounds, giving this tool added value in particular clinical and/or research settings.

  1. Correlation of Admission Metrics with Eventual Success in Mathematics Academic Performance of Freshmen in AMAIUB's Business Curricula

    Science.gov (United States)

    Calucag, Lina S.; Talisic, Geraldo C.; Caday, Aileen B.

    2016-01-01

    This is a correlational study research design, which aimed to determine the correlation of admission metrics with eventual success in mathematics academic performance of the admitted 177 first year students of Bachelor of Science in Business Informatics and 59 first year students of Bachelor of Science in International Studies. Using Pearson's…

  2. Development of the Italian version of the revised Scoliosis Research Society-22 Patient Questionnaire, SRS-22r-I: cross-cultural adaptation, factor analysis, reliability, and validity.

    Science.gov (United States)

    Monticone, Marco; Baiardi, Paola; Calabrò, David; Calabrò, Fabio; Foti, Calogero

    2010-11-15

    Evaluation of the psychometric properties of a translated and culturally adapted questionnaire. Translating, culturally adapting, and validating the Italian version of the revised Scoliosis Research Society-22 Patient Questionnaire (SRS-22r-I) in order to allow its use with Italian-speaking patients with adolescent idiopathic scoliosis (AIS). Increasing attention is being given to health-related quality of life measures as a means of adding information about the evaluation of AIS. A translated form of the revised SRS-22 has never been validated in Italian patients with AIS. The development of the SRS-22 questionnaire involved its translation and back-translation, a final review by an Expert Committee, and testing of the prefinal version to establish its correspondence to the original English version. Psychometric testing included factor analysis, reliability by internal consistency (Cronbach alpha) and test-retest repeatability (Intraclass Coefficient Correlation), and concurrent validity (Pearson correlation) by comparing the SRS-22r-I domains with the Short-Form Health Survey (SF-36) subscales. It took 4 months to develop a shared version of the SRS-22r-I, which proved to be satisfactorily acceptable when administered to 223 subjects with AIS. Factor analysis indicated a 4-factor solution (54% of the explained variance), and the questionnaire had an acceptable level of internal consistency (α = 0.77) and a high level of test-retest reliability (intraclass correlation coefficient = 0.957). In terms of concurrent validity, the correlations with the related Short-Form-36 subscales were moderate to good in the case of the Pain and Mental Health domains, and moderate in the case of the Function and Self-Image domains. The Italian translation of the SRS-22r has a good factorial structure and psychometric properties, and replicates the results of existing English versions of the questionnaire. Its use for research purposes can therefore be recommended.

  3. Is the Pearson r[squared] Biased, and if So, What Is the Best Correction Formula?

    Science.gov (United States)

    Wang, Zhongmiao; Thompson, Bruce

    2007-01-01

    In this study the authors investigated the use of 5 (i.e., Claudy, Ezekiel, Olkin-Pratt, Pratt, and Smith) R[squared] correction formulas with the Pearson r[squared]. The authors estimated adjustment bias and precision under 6 x 3 x 6 conditions (i.e., population [rho] values of 0.0, 0.1, 0.3, 0.5, 0.7, and 0.9; population shapes normal, skewness…

  4. Development of a reliable and construct valid measure of nutritional literacy in adults

    Directory of Open Access Journals (Sweden)

    Diamond James J

    2007-02-01

    Full Text Available Abstract Background Research into the relation of literacy to health status has not included measures of nutritional literacy. This may be a critical area in the study of chronic conditions such as hypertension and diabetes, which can both relate to obesity and nutrition. This paper details the development and psychometric characteristics of the Nutritional Literacy Scale (NLS, offered as a measure of adults' ability to comprehend nutritional information. Methods In order to assess the internal consistency and construct validity of the NLS, demographic data, readability statistics, NLS scores and scores on the Reading Comprehension Section of the Short Test of Functional Health Literacy in Adults (S-TOFHLA were collected in a cross-sectional study of 341 patients from two primary care practices. Results The NLS score showed acceptable internal consistency of 0.84 by Cronbach's alpha coefficient. The Pearson correlation between the NLS and the S-TOFHLA was 0.61, supporting evidence for construct validity. Conclusion Given the importance of proper weight and nutrition in the health of the public, as well as the absence of research on literacy skills as related to nutritional concepts, the NLS has the potential to add to the national research agenda in these areas.

  5. Validity, reliability, and factor analysis of Persian version of quality of life questionnaire for irritable bowel syndrome (IBS-QOL-34

    Directory of Open Access Journals (Sweden)

    Nasrine Masaeli

    2013-01-01

    Full Text Available Background: Quality of life (QOL improvement is the main objective of treating patients with irritable bowel syndrome (IBS. This study aimed to assess the validity, reliability, and factor analysis of IBS-QOL-34 questionnaire as a common transcultural instrument for Iranian IBS patients. Materials and Methods: Two hundred and forty patients with IBS (based on gastroenterologists′ diagnosis according to ROM III criteria were referred to Digestive Health Clinic in Psychosomatic Research Center have been selected in this study. Aside with IBS-QOL-34, MOS 36-item short-form health survey (SF-36 and IBS severity index (IBSSI questionnaires were completed by the cases for determination of correlation coefficients; the data were analyzed using descriptive statistics, factor analysis, Cronbach′s alpha, Pearson correlation coefficient by Statistical Package for Social Sciences (SPSS software, version 18. Results: Total reliability of the questionnaire was reported by using Cronbach′s alpha as 0.95, ranging from 0.65 to 0.90. Correlation coefficients of concurrent implementation of IBS-QOL with SF-36 and IBSSI resulted in −0.61 and 0.64, respectively. Exploratory factor analysis using varimax rotation identified eight principle components, which will determine QOL at 67% variance. Conclusion: According to the results, IBS-QOL-34 questionnaire has good psychometric properties in the research community and can be safely used as a valid tool to assess QOL of patients with IBS for healthcare and therapeutic purposes.

  6. Validation of Patient-Reported Outcomes Measurement Information System Short Forms for Use in Childhood-Onset Systemic Lupus Erythematosus.

    Science.gov (United States)

    Jones, Jordan T; Carle, Adam C; Wootton, Janet; Liberio, Brianna; Lee, Jiha; Schanberg, Laura E; Ying, Jun; Morgan DeWitt, Esi; Brunner, Hermine I

    2017-01-01

    To validate the pediatric Patient-Reported Outcomes Measurement Information System short forms (PROMIS-SFs) in childhood-onset systemic lupus erythematosus (SLE) in a clinical setting. At 3 study visits, childhood-onset SLE patients completed the PROMIS-SFs (anger, anxiety, depressive symptoms, fatigue, physical function-mobility, physical function-upper extremity, pain interference, and peer relationships) using the PROMIS assessment center, and health-related quality of life (HRQoL) legacy measures (Pediatric Quality of Life Inventory, Childhood Health Assessment Questionnaire, Simple Measure of Impact of Lupus Erythematosus in Youngsters [SMILEY], and visual analog scales [VAS] of pain and well-being). Physicians rated childhood-onset SLE activity on a VAS and completed the Systemic Lupus Erythematosus Disease Activity Index 2000. Using a global rating scale of change (GRC) between study visits, physicians rated change of childhood-onset SLE activity (GRC-MD1: better/same/worse) and change of patient overall health (GRC-MD2: better/same/worse). Questionnaire scores were compared in support of validity and responsiveness to change (external standards: GRC-MD1, GRC-MD2). In this population-based cohort (n = 100) with a mean age of 15.8 years (range 10-20 years), the PROMIS-SFs were completed in less than 5 minutes in a clinical setting. The PROMIS-SF scores correlated at least moderately (Pearson's r ≥ 0.5) with those of legacy HRQoL measures, except for the SMILEY. Measures of childhood-onset SLE activity did not correlate with the PROMIS-SFs. Responsiveness to change of the PROMIS-SFs was supported by path, mixed-model, and correlation analyses. To assess HRQoL in childhood-onset SLE, the PROMIS-SFs demonstrated feasibility, internal consistency, construct validity, and responsiveness to change in a clinical setting. © 2016, American College of Rheumatology.

  7. [Validity and Reliability of the Attitudes Toward Sexuality in the Elderly Questionnaire in Cartagena, Colombia].

    Science.gov (United States)

    Melguizo-Herrera, Estela; Álvarez-Romero, Yuleysi; Cabarcas-Mendoza, Mayerlin Vanessa; Calvo-Rodríguez, Rossy Stefanie; Flórez-Almanza, Jeomaidis; Moadie-Contreras, Olga Patricia; Campo-Arias, Adalberto

    2015-01-01

    There are many stereotypes and prejudices about the sexual lives of the elderly. However, there are no validated and reliable tools for measuring these in the Latin-American context. To determine the internal consistency, dimensionality, differential item functioning (DIF) by gender and stability of the Attitudes towards Sexuality in the Elderly Questionnaire (ASEQ) in adults over 60 years-old in Cartagena, Colombia. A validation study was designed that included a sample of 130 participants without cognitive impairment attending a Life Center. The ages ranged between 60 and 90 years (mean, 73.7±8.0), and there were 61.5% females. Internal consistency was calculated using Cronbach alpha and McDonald omega, exploratory factor analysis (EFA) (dimensionality), DIF by gender (item response theory) with Kendall correlation, and stability (reproducibility) with Pearson correlation and intraclass correlation coefficient (ICC). The ASEQ showed high internal consistency on the first application (α=.83 and ω=.87) and in the second one (α=.85 and ω=.89). AFE showed two salient factors (prejudices and limitations) that explained 42.6% of the total variance. The IDF presented appropriate coefficients, with the exception of item 14 that showed a high value (τ=.37). ASEQ showed high stability (r=.82 and ICC=.89; 95% confidence interval, 0.83- 0.92; P<.001). ASEQ is a two-dimensional and reliable scale in older adults attending a Life Center in Cartagena, Colombia. New studies are required to evaluate the performance in a representative sample. Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  8. Development and validation of a beverage and snack questionnaire for use in evaluation of school nutrition policies.

    Science.gov (United States)

    Neuhouser, Marian L; Lilley, Sonya; Lund, Anne; Johnson, Donna B

    2009-09-01

    School nutrition policies limiting access to sweetened beverages, candy, and salty snacks have the potential to improve the health of children. To effectively evaluate policy success, appropriate and validated dietary assessment instruments are needed. The objective of this study was to develop and validate a beverage and snack questionnaire suitable for use among young adolescents. A new 19-item Beverage and Snack Questionnaire (BSQ) was administered to middle school students on two occasions, 2 weeks apart, to measure test-retest reliability. The questionnaire inquired about frequency of consumption, both at school and away from school, of soft drinks, salty snacks, sweets, milk, and fruits and vegetables. Students also completed 4-day food records. To assess validity, food-record data were compared with BSQ data. Forty-six students of diverse backgrounds from metropolitan Seattle, WA, participated in this study. Participants answered the BSQ during class time and completed the food record at home. Pearson correlation coefficients assessed test-retest reliability and validity. Using frequency per week data, the test-retest reliability coefficients were r=0.85 for fruits and vegetables consumed at school and r=0.74 and r=0.72 for beverages and sweets/snacks, respectively, consumed at school. Correlations ranged from r=0.73 to 0.77 for foods consumed outside of school. Compared with the criterion food record, validity coefficients were very good: r=0.69 to 0.71 for foods consumed at school and r=0.63 to 0.70 for foods consumed away from school. The validity coefficients for the 19 individual food items ranged from r=0.56 to 0.87. This easy-to-administer 19-item questionnaire captures data on sugar-sweetened beverages, salty snacks, sweets, milk, and fruit and vegetables as well as a more lengthy and expensive food record does. The BSQ can be used by nutrition researchers and practitioners to accurately evaluate student consumption of foods that are the focus of

  9. The Correlation of Nurses' job Burnout and Their Social Responsibility Considering the Role of Control Locus

    Directory of Open Access Journals (Sweden)

    Reyhane Izedi

    2016-07-01

    Full Text Available Background: Job burnout is an occupational hazard that reduces physical and mental energy of the staff. This study was aimed to investigate the relationship between the nurses' job burnout and their social responsibility considering the moderating role of control locus. Methods: In an analytical and cross-sectional study we used 3 valid questionnaires including Maslach burnout inventory, Dynson social responsibility and Rotter locus of control in 3 educational hospitals of Yazd, Iran. A total of 246 nurses contributed in the study. Data analysis was done through SPSS19. We used Pearson and Kendall correlation coefficient in data analysis. Findings: The mean scores of job burnout and social responsibility of studied group were 60.75 +8.37 and 71.84+15.47, respectively. Job burnout is negatively correlated with social responsibility statistically (r= -0.250 while locus of control acts as the moderator of this correlation. Conclusion: Our results suggest that creating a supportive work environment for nurses enhances their social responsibility trough affecting their level of job burnout. Also, the approved moderating role of control locus in the relationship of job burnout and social responsibility indicates that the personality traits can be considered as the appropriate criteria for entry to nursing schools.

  10. Validação da versão em português europeu de questionário de avaliação funcional multidimensional de idosos Validation of the European Portuguese version of the Older Americans Resources and Services instrument

    Directory of Open Access Journals (Sweden)

    Rogério Manuel Clemente Rodrigues

    2008-02-01

    institutional support. RESULTS: The internal coherence (Cronbach's alpha was between 0.64 and 0.91 for each of the five functional assessment scales included in the instrument. For criterion validity, the relatively low Pearson correlation values obtained (< 0.700 through the Medical Outcomes Study 36-Item Short-Form General Health Survey reflect the challenges associated with establishing a criterion by which new health evaluation instruments might be compared. Pearson's correlation for reproducibility was between 0.859 and 1.0 for all the scales. CONCLUSIONS: The European-Portuguese version of the OARS (Questionário de Avaliação Funcional Multidimensional de Idosos is useful for collecting valid information that can help focus community interventions and promote strategies that specifically target this population group.

  11. Development and validation of the irritable bowel syndrome scale under the system of quality of life instruments for chronic diseases QLICD-IBS: combinations of classical test theory and generalizability theory.

    Science.gov (United States)

    Lei, Pingguang; Lei, Guanghe; Tian, Jianjun; Zhou, Zengfen; Zhao, Miao; Wan, Chonghua

    2014-10-01

    This paper is aimed to develop the irritable bowel syndrome (IBS) scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-IBS) by the modular approach and validate it by both classical test theory and generalizability theory. The QLICD-IBS was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, and quantitative statistical procedures. One hundred twelve inpatients with IBS were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability, and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t tests and also G studies and D studies of generalizability theory analysis. Multi-trait scaling analysis, correlation, and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. Test-retest reliability coefficients (Pearson r and intra-class correlation (ICC)) for the overall score and all domains were higher than 0.80; the internal consistency α for all domains at two measurements were higher than 0.70 except for the social domain (0.55 and 0.67, respectively). The overall score and scores for all domains/facets had statistically significant changes after treatments with moderate or higher effect size standardized response mean (SRM) ranging from 0.72 to 1.02 at domain levels. G coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-IBS has good validity, reliability, responsiveness, and some highlights and can be used as the quality of life instrument for patients with IBS.

  12. Reliability and construct validity of the Spanish version of the 6-item CTS symptoms scale for outcomes assessment in carpal tunnel syndrome.

    Science.gov (United States)

    Rosales, Roberto S; Martin-Hidalgo, Yolanda; Reboso-Morales, Luis; Atroshi, Isam

    2016-03-03

    The purpose of this study was to assess the reliability and construct validity of the Spanish version of the 6-item carpal tunnel syndrome (CTS) symptoms scale (CTS-6). In this cross-sectional study 40 patients diagnosed with CTS based on clinical and neurophysiologic criteria, completed the standard Spanish versions of the CTS-6 and the disabilities of the arm, shoulder and hand (QuickDASH) scales on two occasions with a 1-week interval. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient, two way random effect model and absolute agreement definition (ICC2,1). Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was assessed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 95 % confidence level (MDC95). For assessing construct validity it was hypothesized that the CTS-6 would have a strong positive correlation with the QuickDASH, analyzed with the Pearson correlation coefficient (r). The standard Spanish version of the CTS-6 presented a Cronbach alpha of 0.81 with a SEM of 0.3. Test-retest reliability showed an ICC of 0.85 with a SRMdiff of 0.36 and a MDC95 of 0.7. The correlation between CTS-6 and the QuickDASH was concordant with the a priori formulated construct hypothesis (r 0.69) CONCLUSIONS: The standard Spanish version of the 6-item CTS symptoms scale showed good internal consistency, test-retest reliability and construct validity for outcomes assessment in CTS. The CTS-6 will be useful to clinicians and researchers in Spanish speaking parts of the world. The use of standardized outcome measures across countries also will facilitate comparison of research results in carpal tunnel syndrome.

  13. The Nutrition Literacy Assessment Instrument is a Valid and Reliable Measure of Nutrition Literacy in Adults with Chronic Disease.

    Science.gov (United States)

    Gibbs, Heather D; Ellerbeck, Edward F; Gajewski, Byron; Zhang, Chuanwu; Sullivan, Debra K

    2018-03-01

    To test the reliability and validity of the Nutrition Literacy Assessment Instrument (NLit) in adult primary care and identify the relationship between nutrition literacy and diet quality. This instrument validation study included a cross-sectional sample participating in up to 2 visits 1 month apart. A total of 429 adults with nutrition-related chronic disease were recruited from clinics and a patient registry affiliated with a Midwestern university medical center. Nutrition literacy was measured by the NLit, which was composed of 6 subscales: nutrition and health, energy sources in food, food label and numeracy, household food measurement, food groups, and consumer skills. Diet quality was measured by Healthy Eating Index-2010 with nutrient data from Diet History Questionnaire II surveys. The researchers measured factor validity and reliability by using binary confirmatory factor analysis; test-retest reliability was measured by Pearson r and the intraclass correlation coefficient, and relationships between nutrition literacy and diet quality were analyzed by linear regression. The NLit demonstrated substantial factor validity and reliability (0.97; confidence interval, 0.96-0.98) and test-retest reliability (0.88; confidence interval, 0.85-0.90). Nutrition literacy was the most significant predictor of diet quality (β = .17; multivariate coefficient = 0.10; P measuring nutrition literacy in adult primary care patients. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  14. Validation of a raw data-based synchronization signal (kymogram) for phase-correlated cardiac image reconstruction

    International Nuclear Information System (INIS)

    Ertel, Dirk; Kachelriess, Marc; Kalender, Willi A.; Pflederer, Tobias; Achenbach, Stephan; Steffen, Peter

    2008-01-01

    Phase-correlated reconstruction is commonly used in computed tomography (CT)-based cardiac imaging. Alternatively to the commonly used ECG, the raw data-based kymogram function can be used as a synchronization signal. We used raw data of 100 consecutive patient exams to compare the performance of kymogram function to the ECG signal. For objective validation the correlation of the ECG and the kymogram was assessed. Additionally, we performed a double-blinded comparison of ECG-based and kymogram-based phase-correlated images. The two synchronization signals showed good correlation indicated by a mean difference in the detected heart rate of negligible 0.2 bpm. The mean image quality score was 2.0 points for kymogram-correlated images and 2.3 points for ECG-correlated images, respectively (3: best; 0: worst). The kymogram and the ECG provided images adequate for diagnosis for 93 and 97 patients, respectively. For 50% of the datasets the kymogram provided an equivalent or even higher image quality compared with the ECG signal. We conclude that an acceptable image quality can be assured in most cases by the kymogram. Improvements of image quality by the kymogram function were observed in a noticeable number of cases. The kymogram can serve as a backup solution when an ECG is not available or lacking in quality. (orig.)

  15. A new methodology of spatial cross-correlation analysis.

    Science.gov (United States)

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran's index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson's correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China's urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes.

  16. Correlation of accelerometry with clinical balance tests in older fallers and non-fallers.

    LENUS (Irish Health Repository)

    O'Sullivan, Maura

    2012-02-01

    BACKGROUND: falls are a common cause of injury and decreased functional independence in the older adult. Diagnosis and treatment of fallers require tools that accurately assess physiological parameters associated with balance. Validated clinical tools include the Berg Balance Scale (BBS) and the Timed Up and Go test (TUG); however, the BBS tends to be subjective in nature, while the TUG quantifies an individuals functional impairment but requires further subjective evaluation for balance assessment. Other quantitative alternatives to date require expensive, sophisticated equipment. Measurement of the acceleration of centre of mass, with relatively inexpensive, lightweight, body-mounted accelerometers is a potential solution to this problem. OBJECTIVES: to determine (i) if accelerometry correlates with standard clinical tests (BBS and TUG), (ii) to characterise accelerometer responses to increasingly difficult challenges to balance and (iii) to characterise acceleration patterns between fallers and non-fallers. Study design and setting: torso accelerations were measured at the level of L3 using a tri-axial accelerometer under four conditions; standing unsupported with eyes open (EO), eyes closed (EC) and on a mat with eyes open (MAT EO) and closed (MAT EC). Older patients (n = 21, 8 males, 13 females) with a mean age of 78 (SD +\\/- 7.6) years who attended a day hospital were recruited for this study. Patients were identified as fallers or non-fallers based on a comprehensive falls history. MEASUREMENTS: Spearman\\'s rank correlation analysis examined the relationship between acceleration root mean square (RMS) data and the BBS while Pearson\\'s correlation was used with TUG scores. Differences in accelerometer RMS between fallers and non-fallers and between test conditions were examined using t-test and non-parametric alternatives where appropriate. RESULTS: there was a stepwise increase in accelerometer RMS with increasing task complexity, and the accelerometer

  17. Validation of a Video Analysis Software Package for Quantifying Movement Velocity in Resistance Exercises.

    Science.gov (United States)

    Sañudo, Borja; Rueda, David; Pozo-Cruz, Borja Del; de Hoyo, Moisés; Carrasco, Luis

    2016-10-01

    Sañudo, B, Rueda, D, del Pozo-Cruz, B, de Hoyo, M, and Carrasco, L. Validation of a video analysis software package for quantifying movement velocity in resistance exercises. J Strength Cond Res 30(10): 2934-2941, 2016-The aim of this study was to establish the validity of a video analysis software package in measuring mean propulsive velocity (MPV) and the maximal velocity during bench press. Twenty-one healthy males (21 ± 1 year) with weight training experience were recruited, and the MPV and the maximal velocity of the concentric phase (Vmax) were compared with a linear position transducer system during a standard bench press exercise. Participants performed a 1 repetition maximum test using the supine bench press exercise. The testing procedures involved the simultaneous assessment of bench press propulsive velocity using 2 kinematic (linear position transducer and semi-automated tracking software) systems. High Pearson's correlation coefficients for MPV and Vmax between both devices (r = 0.473 to 0.993) were observed. The intraclass correlation coefficients for barbell velocity data and the kinematic data obtained from video analysis were high (>0.79). In addition, the low coefficients of variation indicate that measurements had low variability. Finally, Bland-Altman plots with the limits of agreement of the MPV and Vmax with different loads showed a negative trend, which indicated that the video analysis had higher values than the linear transducer. In conclusion, this study has demonstrated that the software used for the video analysis was an easy to use and cost-effective tool with a very high degree of concurrent validity. This software can be used to evaluate changes in velocity of training load in resistance training, which may be important for the prescription and monitoring of training programmes.

  18. Development and validation of the Perceived Food Environment Questionnaire in a French-Canadian population.

    Science.gov (United States)

    Carbonneau, Elise; Robitaille, Julie; Lamarche, Benoît; Corneau, Louise; Lemieux, Simone

    2017-08-01

    The present study aimed to develop and validate a questionnaire assessing perceived food environment in a French-Canadian population. A questionnaire, the Perceived Food Environment Questionnaire, was developed assessing perceived accessibility to healthy (nine items) and unhealthy foods (three items). A pre-test sample was recruited for a pilot testing of the questionnaire. For the validation study, another sample was recruited and completed the questionnaire twice. Exploratory factor analysis was performed on the items to assess the number of factors (subscales). Cronbach's α was used to measure internal consistency reliability. Test-retest reliability was assessed with Pearson correlations. Online survey. Men and women from the Québec City area (n 31 in the pre-test sample; n 150 in the validation study sample). The pilot testing did not lead to any change in the questionnaire. The exploratory factor analysis revealed a two-subscale structure. The first subscale is composed of six items assessing accessibility to healthy foods and the second includes three items related to accessibility to unhealthy foods. Three items were removed from the questionnaire due to low loading on the two subscales. The subscales demonstrated adequate internal consistency (Cronbach's α=0·77 for healthy foods and 0·62 for unhealthy foods) and test-retest reliability (r=0·59 and 0·60, respectively; both PFood Environment Questionnaire was developed for a French-Canadian population and demonstrated good psychometric properties. Further validation is recommended if the questionnaire is to be used in other populations.

  19. Validity and reliability of the Arabic version of the Household Food Insecurity Access Scale in rural Lebanon.

    Science.gov (United States)

    Naja, Farah; Hwalla, Nahla; Fossian, Talar; Zebian, Dina; Nasreddine, Lara

    2015-02-01

    To assess the validity and reliability of the Arabic version of the Household Food Insecurity Access Scale (HFIAS) in rural Lebanon. A cross-sectional study on a sample of households with at least one child aged 0-2 years. In a one-to-one interview, participants completed an adapted Arabic version of the HFIAS. In order to evaluate the validity of the HFIAS, basic sociodemographic information, anthropometric measurements of the mother and child, and dietary intake data of the child were obtained. In order to examine reproducibility, the HFIAS was re-administered after 3 months. Rural Lebanon. Mother and child pairs (n 150). Factor analysis of HFIAS items revealed two factors: 'insufficient food quality' and 'insufficient food quantity'. Using Pearson's correlation, food insecurity was inversely associated with mother's and father's education levels, number of cars and electrical appliances in the household, income, weight-for-age and length-for-age of the child and the child's dietary adequacy. In contrast, mother's BMI and crowding index were positively associated with food insecurity scores (P Lebanon, lending further evidence to the utility of the HFIAS in assessing food insecurity in culturally diverse populations.

  20. A comparison of high-frequency cross-correlation measures

    Science.gov (United States)

    Precup, Ovidiu V.; Iori, Giulia

    2004-12-01

    On a high-frequency scale the time series are not homogeneous, therefore standard correlation measures cannot be directly applied to the raw data. There are two ways to deal with this problem. The time series can be homogenised through an interpolation method (An Introduction to High-Frequency Finance, Academic Press, NY, 2001) (linear or previous tick) and then the Pearson correlation statistic computed. Recently, methods that can handle raw non-synchronous time series have been developed (Int. J. Theor. Appl. Finance 6(1) (2003) 87; J. Empirical Finance 4 (1997) 259). This paper compares two traditional methods that use interpolation with an alternative method applied directly to the actual time series.

  1. The relation between Pearson’s correlation coefficient r and Salton’s cosine measure

    NARCIS (Netherlands)

    Egghe, L.; Leydesdorff, L.

    2009-01-01

    The relation between Pearson's correlation coefficient and Salton's cosine measure is revealed based on the different possible values of the division of the L1-norm and the L2-norm of a vector. These different values yield a sheaf of increasingly straight lines which together form a cloud of points,

  2. Development and validation of the Vellore Occupational Therapy Evaluation Scale to assess functioning in people with mental illness.

    Science.gov (United States)

    Samuel, Reema; Russell, Paul Ss; Paraseth, Tapan Kumar; Ernest, Sharmila; Jacob, K S

    2016-08-26

    Available occupational therapy assessment scales focus on specific areas of functioning. There is a need for comprehensive evaluation of diverse aspects of functioning in people with mental illness. To develop a comprehensive assessment scale to evaluate diverse aspects of functioning among people with mental illness and to assess its validity and reliability. Available instruments, which evaluate diverse aspects of functioning in people with mental illness, were retrieved. Relevant items, which evaluate specific functions, were selected by a committee of mental health experts and combined to form a comprehensive instrument. Face and content validity and feasibility were assessed and the new instrument was piloted among 60 patients with mental illness. The final version of the instrument was employed in 151 consecutive clients, between 18 and 60 years of age, who were also assessed using Global Assessment of Functioning (GAF), Occupational Therapy Task Observation Scale (OTTOS), Social Functioning Questionnaire (SFQ), Rosenberg Self Esteem Scale (RSES) and Pai and Kapur Family Burden Interview Schedule (FBIS) by two therapists. The inter-rater reliability and test-retest reliability of the new instrument (Vellore Occupational Therapy Evaluation Scale (VOTES)) were also evaluated. The new scale had good internal consistency (Cronbach's alpha = .817), inter-rater reliability .928 (.877-.958) and test-retest reliability .928 (.868-.961). The correlation between the general behaviour domain (Pearson's Correlation Coefficient [PCC] = -.763, p = .000), task behaviour (PCC = -.829, p = .000), social skills (PCC = -.351, p = .000), intrapersonal skills (PCC = -.208, p = .010), instrumental activities of daily living (IADL) (PCC = -.329, p = .038) and leisure activities (PCC = -.433, p = .005) scores of VOTES with the corresponding domains in the scales used for comparison was statistically significant. The correlation

  3. Cultural adaptation and validation of the Filipino version of Kidney Disease Quality of Life--Short Form (KDQOL-SF version 1.3).

    Science.gov (United States)

    Bataclan, Rommel P; Dial, Ma Antonietta D

    2009-10-01

    Chronic kidney disease is the 10th leading cause of death among Filipinos. Those with chronic kidney disease are exposed to stressors which effect their daily lives. Therefore, assessment of health-related quality of life is important in these patients. The objective of the present study was to translate the Kidney Disease Quality of Life--Short Form version 1.3 (KDQOL-SF ver. 1.3) into Filipino and measure its validity and reliability. Translation and cultural adaptation began with two translations into Filipino, with reconciliation of the forward translators. Pretesting with 10 renal patients, review by experts (nephrologist, translator and dialysis nurse) and back-translation was also done. The final questionnaire was administered to 80 patients with chronic renal disease undergoing haemodialysis for at least 3 months, who could understand Filipino, and were without life-threatening or terminal conditions at the time of the test. A convenience sample of 30 patients from the group had a repeat test 10-14 days after to determine test-retest reliability. Test-retest reliability was assessed by intraclass correlation coefficient and internal consistency reliability was measured by determining the Cronbach's alpha value. Validity was measured using Pearson's correlation between the overall health rating scale and the items from the questionnaire. All of the items showed good test-retest reliability (intraclass correlation coefficient >0.40), ranging from 0.58 (social interaction) to 0.98 (role--emotional). Internal consistency reliability values were acceptable, with Cronbach's alpha ranging from 0.60 (cognitive function) to 0.80 (physical functioning and role--physical). Regarding construct validity, overall health rating in kidney disease-targeted scales was significantly correlated with symptoms/problems, effects of kidney disease and burden of kidney disease. All items in the SF 36 scales had significant correlation with overall health rating (P < 0.05) except

  4. Quantized correlation coefficient for measuring reproducibility of ChIP-chip data

    Directory of Open Access Journals (Sweden)

    Kuroda Mitzi I

    2010-07-01

    Full Text Available Abstract Background Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. Results We develop the Quantized correlation coefficient (QCC that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization, a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. Conclusions To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.

  5. Quantized correlation coefficient for measuring reproducibility of ChIP-chip data.

    Science.gov (United States)

    Peng, Shouyong; Kuroda, Mitzi I; Park, Peter J

    2010-07-27

    Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip) is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. We develop the Quantized correlation coefficient (QCC) that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization), a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.

  6. Reliability, validity, and minimal detectable change of the push-off test scores in assessing upper extremity weight-bearing ability.

    Science.gov (United States)

    Mehta, Saurabh P; George, Hannah R; Goering, Christian A; Shafer, Danielle R; Koester, Alan; Novotny, Steven

    2017-11-01

    Clinical measurement study. The push-off test (POT) was recently conceived and found to be reliable and valid for assessing weight bearing through injured wrist or elbow. However, further research with larger sample can lend credence to the preliminary findings supporting the use of the POT. This study examined the interrater reliability, construct validity, and measurement error for the POT in patients with wrist conditions. Participants with musculoskeletal (MSK) wrist conditions were recruited. The performance on the POT, grip isometric strength of wrist extensors was assessed. The shortened version of the Disabilities of the Arm, Shoulder and Hand and numeric pain rating scale were completed. The intraclass correlation coefficient assessed interrater reliability of the POT. Pearson correlation coefficients (r) examined the concurrent relationships between the POT and other measures. The standard error of measurement and the minimal detectable change at 90% confidence interval were assessed as measurement error and index of true change for the POT. A total of 50 participants with different elbow or wrist conditions (age: 48.1 ± 16.6 years) were included in this study. The results of this study strongly supported the interrater reliability (intraclass correlation coefficient: 0.96 and 0.93 for the affected and unaffected sides, respectively) of the POT in patients with wrist MSK conditions. The POT showed convergent relationships with the grip strength on the injured side (r = 0.89) and the wrist extensor strength (r = 0.7). The POT showed smaller standard error of measurement (1.9 kg). The minimal detectable change at 90% confidence interval for the POT was 4.4 kg for the sample. This study provides additional evidence to support the reliability and validity of the POT. This is the first study that provides the values for the measurement error and true change on the POT scores in patients with wrist MSK conditions. Further research should examine the

  7. Development of a valid Simplified Chinese version of the International Hip Outcome Tool (SC-iHOT-33) in young patients having total hip arthroplasty.

    Science.gov (United States)

    Li, D H; Wang, W; Li, X; Gao, Y L; Liu, D H; Liu, D L; Xu, W D

    2017-01-01

    The International Hip Outcome Tool (iHOT-33) is a questionnaire designed for young, active patients with hip disorders. It has proven to be a highly reliable and valid questionnaire. The main purpose of our study was to adapt the iHOT-33 questionnaire into simplified Chinese and to assess its psychometric properties in Chinese patients. The iHOT-33 was cross culturally adapted into Chinese and 138 patients completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the EuroQol-5D (EQ-5D), and the Chinese version of the iHOT-33(SC-iHOT-33) pre- or postoperatively within 6 months' follow-up. The Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) were calculated to assess the reliability, validity, and responsiveness of the SC-iHOT-33, respectively. Total Cronbach's alpha was 0.965, which represented excellent internal consistency of the SC-iHOT-33. The ICC ranges from 0.866 to 0.929, which shows excellent test-retest reliability. The subscales of SC-iHOT-33 had the highest correlation coefficient (r = 0.812) with the physical function subscales of the WOMAC, as well as good correlation between the social/emotional subscale of the SC-iHOT-33 and the EQ-5D (r = 0.740, r = 0.743). No floor or ceiling effects were found. The ES and SRM values indicated good responsiveness of 2.44 and 2.67, respectively. The SC-iHOT-33 questionnaire is reliable, valid, and responsive for the evaluation of young, Chinese, active patients with hip disorders. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  8. Reliability and validity of psychosocial and environmental correlates measures of physical activity and screen-based behaviors among Chinese children in Hong Kong

    Directory of Open Access Journals (Sweden)

    Salmon Jo

    2011-03-01

    Full Text Available Abstract Background Insufficient participation in physical activity and excessive screen time have been observed among Chinese children. The role of social and environmental factors in shaping physical activity and sedentary behaviors among Chinese children is under-investigated. The purpose of the present study was to assess the reliability and validity of a questionnaire to measure child- and parent-reported psychosocial and environmental correlates of physical activity and screen-based behaviors among Chinese children in Hong Kong. Methods A total of 303 schoolchildren aged 9-14 years and their parents volunteered to participate in this study and 160 of them completed the questionnaire twice within an interval of 10 days. Intraclass correlation coefficients (ICCs, kappa statistics, and percent agreement were performed to evaluate test-retest reliability of the continuous and categorical variables, respectively. Exploratory factor analyses (EFAs were conducted to assess convergent validity of the emergent scales. Cronbach's alpha and ICCs were performed to assess internal and test-retest reliability of the emergent scales. Criterion validity was assessed by correlating psychosocial and environmental measures with self-reported physical activity and screen-based behaviors, measured by a validated questionnaire. Results Reliability statistics for both child- and parent-reported continuous variables showed acceptable consistency for all of the ICC values greater than 0.70. Kappa statistics showed fair to perfect test-retest reliability for the categorical items. Adequate internal consistency and test-retest reliability were observed in most of the emergent scales. Criterion validity assessed by correlating psychosocial and environmental measures with child-reported physical activity found associations with physical activity in the self-efficacy scale (r = 0.25, P r = 0.25, P r = 0.14, P r = -0.22, P r = 0.12, P = 0.053. Conclusions The findings

  9. Cross-cultural adaptation, reliability and validity of the Spanish version of the Quality of Life in Adult Cancer Survivors (QLACS) questionnaire: application in a sample of short-term survivors.

    Science.gov (United States)

    Escobar, Antonio; Trujillo-Martín, Maria del Mar; Rueda, Antonio; Pérez-Ruiz, Elisabeth; Avis, Nancy E; Bilbao, Amaia

    2015-11-16

    The aim of this study was to validate the Quality of Life in Adult Cancer Survivors (QLACS) in short-term Spanish cancer survivor's patients. Patients with breast, colorectal or prostate cancer that had finished their initial cancer treatment 3 years before the beginning of this study completed QLACS, WHOQOL, Short Form-36, Hospital Anxiety and Depression Scale, EORTC-QLQ-BR23 and EQ-5D. Cultural adaptation was made based on established guidelines. Reliability was evaluated using internal consistency and test-retest. Convergent validity was studied by mean of Pearson's correlation coefficient. Structural validity was determined by a second-order confirmatory factor analysis (CFA) and Rasch analysis was used to assess the unidimensionality of the Generic and Cancer-specific scales. Cronbach's alpha were above 0.7 in all domains and summary scales. Test-retest coefficients were 0.88 for Generic and 0.82 for Cancer-specific summary scales. QLACS generic summary scale was correlated with other generic criterion measures, SF-36 MCS (r = - 0.74) and EQ-VAS (r = - 0.63). QLACS cancer-specific scale had lower values with the same constructs. CFA provided satisfactory fit indices in all cases. The RMSEA value was 0.061 and CFI and TLI values were 0.929 and 0.925, respectively. All factor loadings were higher than 0.40 and statistically significant (P validity and reliability of QLACS questionnaire to be used in short-term cancer survivors.

  10. The development and validation of measures to assess cooking skills and food skills.

    Science.gov (United States)

    Lavelle, Fiona; McGowan, Laura; Hollywood, Lynsey; Surgenor, Dawn; McCloat, Amanda; Mooney, Elaine; Caraher, Martin; Raats, Monique; Dean, Moira

    2017-09-02

    With the increase use of convenience food and eating outside the home environment being linked to the obesity epidemic, the need to assess and monitor individuals cooking and food skills is key to help intervene where necessary to promote the usage of these skills. Therefore, this research aimed to develop and validate a measure for cooking skills and one for food skills, that are clearly described, relatable, user-friendly, suitable for different types of studies, and applicable across all sociodemographic levels. Two measures were developed in light of the literature and expert opinion and piloted for clarity and ease of use. Following this, four studies were undertaken across different cohorts (including a sample of students, both 'Food preparation novices' and 'Experienced food preparers', and a nationally representative sample) to assess temporal stability, psychometrics, internal consistency reliability and construct validity of both measures. Analysis included T-tests, Pearson's correlations, factor analysis, and Cronbach's alphas, with a significance level of 0.05. Both measures were found to have a significant level of temporal stability (P cooking skills confidence measure ranged from 0.78 to 0.93 across all cohorts. The food skills confidence measure's Cronbach's alpha's ranged from 0.85 to 0.94. The two measures also showed a high discriminate validity as there were significant differences (P cooking skills confidence and P cooking skills confidence measure and the food skills confidence measure have been shown to have a very satisfactory reliability, validity and are consistent over time. Their user-friendly applicability make both measures highly suitable for large scale cross-sectional, longitudinal and intervention studies to assess or monitor cooking and food skills levels and confidence.

  11. A new consensus measure based on Pearson correlation coefficient

    OpenAIRE

    Chiclana, Francisco; Gonzalez-Arteaga, Teresa; de Andres Calle, Rocio

    2016-01-01

    Obtaining consensual solutions is an important issue in decision making processes. It depends on several factors such as experts’ opinions, principles, knowledge, experience, etc. In the literature we can find a considerable amount of consensus measurement from different research areas (from a Social Choice perspective: Alcalde-Unzu and Vorsatz [1], Alcantud, de Andres Calle and Cascon [2] and Bosch [3], among others and from Decision Making Theory: Gonzalez-Arteaga, Alcantud and ...

  12. Parental Socio-Economic Status as Correlate of Child Labour in Ile-Ife, Nigeria

    Science.gov (United States)

    Elegbeleye, O. S.; Olasupo, M. O.

    2012-01-01

    This study investigated the relationship between parental socio-economic status and child labour practices in Ile-Ife, Nigeria. The study employed survey method to gather data from 200 parents which constituted the study population. Pearson Product Moment Correlation and t-test statistics were used for the data analyses. The outcome of the study…

  13. Addenbrooke's cognitive examination III: diagnostic utility for mild cognitive impairment and dementia and correlation with standardized neuropsychological tests.

    Science.gov (United States)

    Matias-Guiu, Jordi A; Cortés-Martínez, Ana; Valles-Salgado, Maria; Rognoni, Teresa; Fernández-Matarrubia, Marta; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Addenbrooke's Cognitive Examination III (ACE-III) is a screening test that was recently validated for diagnosing dementia. Since it assesses attention, language, memory, fluency, and visuospatial function separately, it may also be useful for general neuropsychological assessments. The aim of this study was to analyze the tool's ability to detect early stages of Alzheimer's disease and to examine the correlation between ACE-III scores and scores on standardized neuropsychological tests. Our study included 200 participants categorized as follows: 25 healthy controls, 48 individuals with subjective memory complaints, 47 patients with amnestic mild cognitive impairment and 47 mild Alzheimer's disease, and 33 patients with other neurodegenerative diseases. The ACE-III memory and language domains were highly correlated with the neuropsychological tests specific to those domains (Pearson correlation coefficient of 0.806 for total delayed recall on the Free and Cued Selective Reminding Test vs. 0.744 on the Boston Naming Test). ACE-III scores discriminated between controls and patients with amnestic mild cognitive impairment (AUC: 0.906), and between controls and patients with mild Alzheimer's disease (AUC: 0.978). Our results suggest that ACE-III is a useful neuropsychological test for assessing the cognitive domains of attention, language, memory, and visuospatial function. It also enables detection of Alzheimer's disease in early stages.

  14. Development and validation of in vitro-in vivo correlation (IVIVC) for estradiol transdermal drug delivery systems.

    Science.gov (United States)

    Yang, Yang; Manda, Prashanth; Pavurala, Naresh; Khan, Mansoor A; Krishnaiah, Yellela S R

    2015-07-28

    The objective of this study was to develop a level A in vitro-in vivo correlation (IVIVC) for drug-in-adhesive (DIA) type estradiol transdermal drug delivery systems (TDDS). In vitro drug permeation studies across human skin were carried out to obtain the percent of estradiol permeation from marketed products. The in vivo time versus plasma concentration data of three estradiol TDDS at drug loadings of 2.0, 3.8 and 7.6mg (delivery rates of 25, 50 and 100μg/day, respectively) was deconvoluted using Wagner-Nelson method to obtain percent of in vivo drug absorption in postmenopausal women. The IVIVC between the in vitro percent of drug permeation (X) and in vivo percent of drug absorption (Y) for these three estradiol TDDS was constructed using GastroPlus® software. There was a high correlation (R(2)=1.0) with a polynomial regression of Y=-0.227X(2)+0.331X-0.001. These three estradiol TDDS were used for internal validation whereas another two products of the same formulation design (with delivery rates of 60 and 100μg/day) were used for external validation. The predicted estradiol serum concentrations (convoluted from in vitro skin permeation data) were compared with the observed serum concentrations for the respective products. The developed IVIVC model passed both the internal and external validations as the prediction errors (%PE) for Cmax and AUC were less than 15%. When another marketed estradiol TDDS with a delivery rate of 100μg/day but with a slight variation in formulation design was chosen, it did not pass external validation indicating the product-specific nature of IVIVC model. Results suggest that the IVIVC model developed in this study can be used to successfully predict the in vivo performance of the same estradiol TDDS with in vivo delivery rates ranging from 25 to 100μg/day. Published by Elsevier B.V.

  15. Validity and reliability of the Spanish-language version of the self-administered Leeds Assessment of Neuropathic Symptoms and Signs (S-LANSS) pain scale.

    Science.gov (United States)

    López-de-Uralde-Villanueva, I; Gil-Martínez, A; Candelas-Fernández, P; de Andrés-Ares, J; Beltrán-Alacreu, H; La Touche, R

    2016-12-08

    The self-administered Leeds Assessment of Neuropathic Symptoms and Signs (S-LANSS) scale is a tool designed to identify patients with pain with neuropathic features. To assess the validity and reliability of the Spanish-language version of the S-LANSS scale. Our study included a total of 182 patients with chronic pain to assess the convergent and discriminant validity of the S-LANSS; the sample was increased to 321 patients to evaluate construct validity and reliability. The validated Spanish-language version of the ID-Pain questionnaire was used as the criterion variable. All participants completed the ID-Pain, the S-LANSS, and the Numerical Rating Scale for pain. Discriminant validity was evaluated by analysing sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). Construct validity was assessed with factor analysis and by comparing the odds ratio of each S-LANSS item to the total score. Convergent validity and reliability were evaluated with Pearson's r and Cronbach's alpha, respectively. The optimal cut-off point for S-LANSS was ≥12 points (AUC=.89; sensitivity=88.7; specificity=76.6). Factor analysis yielded one factor; furthermore, all items contributed significantly to the positive total score on the S-LANSS (P<.05). The S-LANSS showed a significant correlation with ID-Pain (r=.734, α=.71). The Spanish-language version of the S-LANSS is valid and reliable for identifying patients with chronic pain with neuropathic features. Copyright © 2016 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Development and validation of the coronary heart disease scale under the system of quality of life instruments for chronic diseases QLICD-CHD: combinations of classical test theory and Generalizability Theory.

    Science.gov (United States)

    Wan, Chonghua; Li, Hezhan; Fan, Xuejin; Yang, Ruixue; Pan, Jiahua; Chen, Wenru; Zhao, Rong

    2014-06-04

    Quality of life (QOL) for patients with coronary heart disease (CHD) is now concerned worldwide with the specific instruments being seldom and no one developed by the modular approach. This paper is aimed to develop the CHD scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-CHD) by the modular approach and validate it by both classical test theory and Generalizability Theory. The QLICD-CHD was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, pre-testing and quantitative statistical procedures. 146 inpatients with CHD were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t-tests and also G studies and D studies of Genralizability Theory analysis. Multi-trait scaling analysis, correlation and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. The internal consistency α and test-retest reliability coefficients (Pearson r and Intra-class correlations ICC) for the overall instrument and all domains were higher than 0.70 and 0.80 respectively; The overall and all domains except for social domain had statistically significant changes after treatments with moderate effect size SRM (standardized response mea) ranging from 0.32 to 0.67. G-coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-CHD has good validity, reliability, and moderate responsiveness and some highlights, and can be used as the quality of life instrument for patients with CHD. However, in order to obtain better reliability, the numbers of items for social domain should be increased or the items' quality, not quantity, should be

  17. Correlation between the pain numeric rating scale and the 12-item WHO Disability Assessment Schedule 2.0 in patients with musculoskeletal pain.

    Science.gov (United States)

    Saltychev, Mikhail; Bärlund, Esa; Laimi, Katri

    2018-03-01

    The aim of this study was to assess the correlation between pain severity measured on a numeric rating scale and restrictions of functioning measured with the WHO Disability Assessment Schedule (WHODAS 2.0). This was a cross-sectional study of 1207 patients with musculoskeletal pain conditions. Correlation was assessed using Spearman's and Pearson tests. Although all the Spearman's rank correlations between WHODAS 2.0 items and pain severity were statistically significant, they were mostly weak, with only a few moderate associations for 'S2 household responsibilities', 'S8 washing', 'S9 dressing', and 'S12 day-to-day work'. The correlation between the WHODAS 2.0 total score and pain severity was also moderate: 0.41 [95% confidence interval (CI): 0.36-0.45] for average pain and 0.42 (95% CI: 0.37-0.46) for worst pain. The correlation between the WHODAS 2.0 total score and pain level was also assessed using Pearson's product-moment correlation, yielding figures that were similar to Spearman's correlation: 0.42 (Pcorrelation between pain severity measured by numeric rating scale and functioning level measured by WHODAS 2.0 was weak to moderate, with slightly stronger associations in physical domains of functioning.

  18. The Utility of Digital Rectal Examination in Estimating Prostate ...

    African Journals Online (AJOL)

    This is further validated by the Pearson's correlation test ascertaining ... 25 g); about the size of a plum and occupies a bit < 1/4th of the .... management of BPH. ... Principles and Practice of Surgery Including Pathology in the Tropics. 3rd ed.

  19. Retrieval of savanna vegetation canopy height from ICESat-GLAS spaceborne LiDAR with terrain correction

    CSIR Research Space (South Africa)

    Khalefa, E

    2013-11-01

    Full Text Available variability (slope) and canopy height within the GLAS footprints. The canopy height retrievals were validated with field observations in 23 GLAS footprints and show that the direct method works well over flat areas (Pearson correlation coefficient r = 0.70, p...

  20. [Validity, reliability, and acceptability of the brief version of the self-management knowledge, attitude, and behavior assessment scale for diabetes patients].

    Science.gov (United States)

    Wu, Y Z; Wang, W J; Feng, N P; Chen, B; Li, G C; Liu, J W; Liu, H L; Yang, Y Y

    2016-07-06

    To evaluate the validity, reliability, and acceptability of the brief version of the self-management knowledge, attitude, and behavior (KAB) assessment scale for diabetes patients. Diabetes patients who were managed at the Xinkaipu Community Health Service Center of Tianxin in Changsha, Hunan Province were selected for survey by cluster sampling. A total of 350 diabetes patients were surveyed using the brief scale to collect data on knowledge, attitudes, and behaviors of self-management. Content validity was evaluated by Pearson correlation coefficient between the brief scale and subscales of knowledge, attitude, and behavior. Structure validity was evaluated by factor analysis, and discrimination validity was evaluated by an independent sample t-test between the high-score and low-score groups. Reliability was tested by internal consistency reliability and split-half reliability. The evaluation indexes of internal consistency reliability were Cronbach's α coefficients, θ coefficient, and Ω coefficient. Acceptability was evaluated by valid response rate and completion time of the brief scale. A total of 346(98.9%) valid questionnaires were returned, with average survey time of (11.43±3.4) minutes. Average score of the brief scale was 78.85 ± 11.22; scores of the knowledge, attitude, and behavior subscales were 16.45 ± 4.42, 21.33 ± 2.03, and 41.07 ± 8.34, respectively. Pearson correlation coefficients between the brief scale and the knowledge, attitude, and behavior subscales were 0.92, 0.42, and 0.60, respectively; P-values were all less than 0.01, indicating that the face validity and content validity of the brief scale were achieved to a good level. The common factor cumulative variance contribution rate of the brief scale and three subscales was from 53.66% to 61.75%, which achieved more than 50% of the approved standard. There were 11 common factors; 41 of the total 42 items had factor loadings above 0.40 in their relevant common factor, indicating

  1. Quality of Life and Bronchial Hyper-Responsiveness in Subjects With Bronchiectasis: Validation of the Seattle Obstructive Lung Disease Questionnaire in Bronchiectasis.

    Science.gov (United States)

    Bulcun, Emel; Arslan, Mesut; Ekici, Aydanur; Ekici, Mehmet

    2015-11-01

    Bronchiectasis can adversely affect quality of life. However, the tests examining quality of life in bronchiectasis are not sufficient. We examined the validity of a measure designed for COPD, the Seattle Obstructive Lung Disease Questionnaire (SOLQ), in bronchiectasis. In addition, we aimed to compare the quality of life of subjects with bronchiectasis and bronchial hyper-responsiveness with that of those without to identify the effective factors. We studied 78 subjects with clinically stable bronchiectasis and 41 healthy controls matched for age and sex. Subjects were assessed by the SOLQ. A detailed history, physical examination, the Medical Outcomes Study 36-Item Short Form questionnaire, the Hospital Anxiety and Depression Scale, and spirometric measurements were obtained. Cronbach α coefficients, which reflected internal consistency, were >0.70 for all SOLQ components except for treatment satisfaction. SOLQ component scores correlated with all of the component scores of the Medical Outcomes Study 36-Item Short Form questionnaire and the Hospital Anxiety and Depression Scale, confirming their concurrent validity. All SOLQ scores correlated positively with percent-of-predicted FEV1, whereas the physical function, treatment satisfaction, and emotional function correlated negatively with the exacerbation frequency in Pearson analysis. Emotional and physical functions were positively associated with percent-of-predicted FEV1 in linear regression analysis. Compared with subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had lower FEV1/FVC and more exacerbations/y. Compared with bronchiectasis subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had significantly lower SOLQ, physical function, and coping skills scores but not emotional function and treatment satisfaction. The SOLQ is a valid instrument for determining quality of life in subjects with bronchiectasis. Subjects with

  2. Ecological restoration experiments (1992-2007) at the G.A. Pearson Natural Area, Fort Valley Experimental Forest (P-53)

    Science.gov (United States)

    Margaret M. Moore; Wallace Covington; Peter Z. Fulé; Stephen C. Hart; Thomas E. Kolb; Joy N. Mast; Stephen S. Sackett; Michael R. Wagner

    2008-01-01

    In 1992 an experiment was initiated at the G. A. Pearson Natural Area on the Fort Valley Experimental Forest to evaluate long-term ecosystem responses to two restoration treatments: thinning only and thinning with prescribed burning. Fifteen years of key findings about tree physiology, herbaceous, and ecosystem responses are presented.

  3. Translation, Validation, and Reliability of the Dutch Late-Life Function and Disability Instrument Computer Adaptive Test.

    Science.gov (United States)

    Arensman, Remco M; Pisters, Martijn F; de Man-van Ginkel, Janneke M; Schuurmans, Marieke J; Jette, Alan M; de Bie, Rob A

    2016-09-01

    Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDI-CAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean=4.5 days). Pearson's r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were -.57 and -.53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. The Dutch LLFDI

  4. Initial validation of a virtual-reality learning environment for prostate biopsies: realism matters!

    Science.gov (United States)

    Fiard, Gaelle; Selmi, Sonia-Yuki; Promayon, Emmanuel; Vadcard, Lucile; Descotes, Jean-Luc; Troccaz, Jocelyne

    2014-04-01

    A virtual-reality learning environment dedicated to prostate biopsies was designed to overcome the limitations of current classical teaching methods. The aim of this study was to validate reliability, face, content, and construct of the simulator. The simulator is composed of (a) a laptop computer, (b) a haptic device with a stylus that mimics the ultrasound probe, (c) a clinical case database including three-dimensional (3D) ultrasound volumes and patient data, and (d) a learning environment with a set of progressive exercises including a randomized 12-core biopsy procedure. Both visual (3D biopsy mapping) and numerical (score) feedback are given to the user. The simulator evaluation was conducted in an academic urology department on 7 experts and 14 novices who each performed a virtual biopsy procedure and completed a face and content validity questionnaire. The overall realism of the biopsy procedure was rated at a median of 9/10 by nonexperts (7.1-9.8). Experts rated the usefulness of the simulator for the initial training of urologists at 8.2/10 (7.9-8.3), but reported the range of motion and force feedback as significantly less realistic than novices (P=0.01 and 0.03, respectively). Pearson r correlation coefficient between correctly placed biopsies on the right and left side of the prostate for each user was 0.79 (Prealism and scoring system used.

  5. Hair cortisol detection in dairy cattle by using EIA: protocol validation and correlation with faecal cortisol metabolites.

    Science.gov (United States)

    Tallo-Parra, O; Manteca, X; Sabes-Alsina, M; Carbajal, A; Lopez-Bejar, M

    2015-06-01

    Hair may be a useful matrix to detect cumulative cortisol concentrations in studies of animal welfare and chronic stress. The aim of this study was to validate a protocol for cortisol detection in hair from dairy cattle by enzyme immunoassay (EIA). Seventeen adult Holstein-Friesian dairy cows were used during the milking period. Hair cortisol concentration was assessed in 25-day-old hair samples taken from the frontal region of the head, analysing black and white coloured hair separately. Concentrations of cortisol metabolites were determined in faeces collected twice a week during the same period of time. There was a high correlation between cortisol values in faeces and cortisol in white colour hair samples but such correlation was not significant with the black colour hair samples. The intra- and inter-assay coefficients of variation were 4.9% and 10.6%, respectively. The linearity showed R 2=0.98 and mean percentage error of -10.8 ± 1.55%. The extraction efficiency was 89.0 ± 23.52% and the parallelism test showed similar slopes. Cortisol detection in hair by using EIA seems to be a valid method to represent long-term circulating cortisol levels in dairy cattle.

  6. Development and validation of a new condition-specific instrument for evaluation of smile esthetics-related quality of life.

    Science.gov (United States)

    Saltovic, Ema; Lajnert, Vlatka; Saltovic, Sabina; Kovacevic Pavicic, Daniela; Pavlic, Andrej; Spalj, Stjepan

    2018-03-01

    Orofacial esthetics raises psychosocial issues. The purpose was to create and validate new short instrument for psychosocial impacts of altered smile esthetics. A team of an orthodontist, two prosthodontists, psychologist, and a dental student generated items that could draw up specific hypothetical psychosocial dimensions (69 items initially, 39 in final analysis). The sample consisted of 261 Caucasian subjects attending local high schools and university (26% male) aged 14 to 28 years that have self-administrated the designed questionnaire. Factorial analysis, Cronbach's alpha, Pearson correlation, paired samples t-test and analysis of variance were used for analyses of internal consistency, construct validity, responsiveness, and test-retest. Three dimensions of psychosocial impacts of altered smile esthetics were identified: dental self-consciousness, dental self-confidence and social contacts that can be best fitted by 12 items, 4 items in each dimension. Internal consistency was good (α in range 0.85-0.89). Good stability in test-retest was confirmed. In responsiveness testing, tooth whitening induced increase in dental self-confidence (P = 0.002), but no significant changes in other dimensions. The new instrument, Smile Esthetics-Related Quality of Life (SERQoL), is short and has proven to be a good indicator of psychosocial dimensions related to perception of smile esthetics. Smile Esthetics-Related Quality of Life questionnaire might have practical validity when applied in esthetic dental clinical procedures. © 2017 Wiley Periodicals, Inc.

  7. Applied TICs in Education and its correlation in Academic Performance

    Directory of Open Access Journals (Sweden)

    Jenny Maritza Rosero Lozano

    2016-08-01

    Full Text Available In the present study, we want to determinate the correlation between educational TICS application and the academic effiency in the subject of programmation in Structured languages which lasted 10 months and It was developed with 5 educators, 73 legal representatives and 103 students who belong to the services Technician bachelor, speciality in Informatic applications. It is based in the Constructivism by Jean Piaget, in the techniques focused in the personalized teaching in the significant learning theory by D´ıaz Barriga. The correlation coefficient by Pearson was used for measuring the different variables. The results revealed the low academic effiency of the students in the subject. It motivated the development of a propose which was a ”WEBQUEST”designed in Exelearning that allows to create learning materials which combine text with multimedia elements and It does not require internet to execute the functions with the purpose of facilitating the student body development in its abilities, capacities and skills, the educator can use it as a didatic strategy because It helps to keep an active and creative participation of the students and It allows to the users to acquire knowledge and skills in the computer programms creation. The software was tested and validated by the educational community, It has as a result a big acceptance, good perspectives in its use and the improvement in the students academic effiency.

  8. Translation, Cultural Adaptation, and Validation of Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) and Self-Complete Leeds Assessment of Neuropathic Symptoms and Signs (S-LANSS) Questionnaires into the Greek Language.

    Science.gov (United States)

    Batistaki, Chrysanthi; Lyrakos, George; Drachtidi, Kalliopi; Stamatiou, Georgia; Kitsou, Maria-Chrysanthi; Kostopanagiotou, Georgia

    2016-06-01

    The LANSS and S-LANSS questionnaires represent two widely accepted and validated instruments used to assist the identification of neuropathic pain worldwide. The aim of this study was to translate, culturally adapt, and validate the LANSS and S-LANSS questionnaires into the Greek language. Forward and backward translations of both questionnaires were performed from the English to Greek language. The final versions were assessed by a committee of clinical experts, and they were then pilot-tested in 20 patients with chronic pain. Both questionnaires were validated in 200 patients with chronic pain (100 patients for each questionnaire), using as the "gold standard" the diagnosis of a clinical expert in pain management. Sensitivity and specificity of questionnaires were assessed, as well as the internal consistency (using Cronbach's alpha coefficient) and correlation with the "gold standard" diagnosis (using Pearson correlation coefficient). Sensitivity and specificity of the LANSS questionnaire were calculated to be 82.76% and 95.24%, while for the S-LANSS 86.21% and 95.24%, respectively. Positive predictive value for neuropathic pain was 96% for the LANSS and 96.15% for the S-LANSS. Cronbach's alpha was revealed to be acceptable for both questionnaires (0.65 for LANSS and 0.67 for the S-LANSS), while a significant correlation was observed compared to the "gold standard" diagnosis (rLANSS   = 0.79 και tSLANSS   = 0.77, respectively, P = 0.01). The LANSS and the S-LANSS diagnostic tools have been translated and validated into the Greek language and can be adequately used to assist the identification of neuropathic pain in everyday clinical practice. © 2015 World Institute of Pain.

  9. Assessment of heat transfer correlations for supercritical water in the frame of best-estimate code validation

    International Nuclear Information System (INIS)

    Jaeger, Wadim; Espinoza, Victor H. Sanchez; Schneider, Niko; Hurtado, Antonio

    2009-01-01

    Within the frame of the Generation IV international forum six innovative reactor concepts are the subject of comprehensive investigations. In some projects supercritical water will be considered as coolant, moderator (as for the High Performance Light Water Reactor) or secondary working fluid (one possible option for Liquid Metal-cooled Fast Reactors). Supercritical water is characterized by a pronounced change of the thermo-physical properties when crossing the pseudo-critical line, which goes hand in hand with a change in the heat transfer (HT) behavior. Hence, it is essential to estimate, in a proper way, the heat-transfer coefficient and subsequently the wall temperature. The scope of this paper is to present and discuss the activities at the Institute for Reactor Safety (IRS) related to the implementation of correlations for wall-to-fluid HT at supercritical conditions in Best-Estimate codes like TRACE as well as its validation. It is important to validate TRACE before applying it to safety analyses of HPLWR or of other reactor systems. In the past 3 decades various experiments have been performed all over the world to reveal the peculiarities of wall-to-fluid HT at supercritical conditions. Several different heat transfer phenomena such as HT enhancement (due to higher Prandtl numbers in the vicinity of the pseudo-critical point) or HT deterioration (due to strong property variations) were observed. Since TRACE is a component based system code with a finite volume method the resolution capabilities are limited and not all physical phenomena can be modeled properly. But Best -Estimate system codes are nowadays the preferred option for safety related investigations of full plants or other integral systems. Thus, the increase of the confidence in such codes is of high priority. In this paper, the post-test analysis of experiments with supercritical parameters will be presented. For that reason various correlations for the HT, which considers the characteristics

  10. The reliability, minimal detectable change and concurrent validity of a gravity-based bubble inclinometer and iphone application for measuring standing lumbar lordosis.

    Science.gov (United States)

    Salamh, Paul A; Kolber, Morey

    2014-01-01

    To investigate the reliability, minimal detectable change (MDC90) and concurrent validity of a gravity-based bubble inclinometer (inclinometer) and iPhone® application for measuring standing lumbar lordosis. Two investigators used both an inclinometer and an iPhone® with an inclinometer application to measure lumbar lordosis of 30 asymptomatic participants. ICC models 3,k and 2,k were used for the intrarater and interrater analysis, respectively. Good interrater and intrarater reliability was present for the inclinometer with Intraclass Correlation Coefficients (ICC) of 0.90 and 0.85, respectively and the iPhone® application with ICC values of 0.96 and 0.81. The minimal detectable change (MDC90) indicates that a change greater than or equal to 7° and 6° is needed to exceed the threshold of error using the iPhone® and inclinometer, respectively. The concurrent validity between the two instruments was good with a Pearson product-moment coefficient of correlation (r) of 0.86 for both raters. Ninety-five percent limits of agreement identified differences ranging from 9° greater in regards to the iPhone® to 8° less regarding the inclinometer. Both the inclinometer and iPhone® application possess good interrater reliability, intrarater reliability and concurrent validity for measuring standing lumbar lordosis. This investigation provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying standing lumbar lordosis. Clinicians should recognize potential individual differences when using these devices interchangeably.

  11. [Development of an evaluation instrument for service quality in nursing homes].

    Science.gov (United States)

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  12. Self-Efficacy and Locus of Control as Predictors of Academic ...

    African Journals Online (AJOL)

    the procrastination behaviour of 300 undergraduate students from a Nigerian university. The participants responded to three valid scales (General Perceived Self Efficacy Scale, Locus of Control Scale and the procrastination scale). Data was analyzed using the Pearson product moment correlation and Multiple regression ...

  13. Assessing the validity of a self-administered food-frequency questionnaire (FFQ) in the adult population of Newfoundland and Labrador, Canada

    Science.gov (United States)

    2013-01-01

    Background The Food- Frequency Questionnaire (FFQ) is a dietary assessment tool frequently used in large-scale nutritional epidemiology studies. The goal of the present study is to validate a self-administered version of the Hawaii FFQ modified for use in the general adult population of Newfoundland and Labrador (NL). Methods Over a one year period, 195 randomly selected adults completed four 24-hour dietary recalls (24-HDRs) by telephone and one subsequent self-administered FFQ. Estimates of energy and nutrients derived from the 24-HDRs and FFQs were compared (protein, carbohydrate, fibre, fat, vitamin A, carotene, vitamin D, and calcium). Data were analyzed using the Pearson’s correlation coefficients, cross-classification method, and Bland–Altman plots. Results The mean nutrient intake values of the 24-HDRs were lower than those of the FFQs, except for protein in men. Sex and energy-adjusted de-attenuated Pearson correlation coefficients for each nutrient varied from 0.13 to 0.61. Except for protein in men, all correlations were statistically significant with p food consumption in the general adult population of NL. This tool can be used to classify individual energy and nutrient intakes into quartiles, which is useful in examining relationships between diet and chronic disease. PMID:23590645

  14. Translation, adaptation and measurement properties of an electronic version of the Danish Western Ontario Shoulder Instability Index (WOSI)

    DEFF Research Database (Denmark)

    Eshoj, Henrik; Bak, Klaus; Blønd, Lars

    2017-01-01

    OBJECTIVES: To translate and adapt the Western Ontario Shoulder Instability (WOSI) questionnaire into Danish and, to evaluate measurement properties of an electronic Danish WOSI version. METHODS: The Swedish WOSI version was used for translation and adaptation into Danish followed by examination...... Shoulder Score (OSS). Reproducibility was evaluated with Intraclass correlations (ICC), Standard Error of Measurement (SEM), minimal detectable change (MDC) and limits of agreement (LOA). Validity was evaluated with Pearson's (r) and Concordance Correlation Coefficients (CCC). RESULTS: 41 subjects (median...... presented excellent test-retest reproducibility and acceptable measurement errors. Also, concurrent validity between paper and electronic version was highly satisfactory as was the construct validity. Surprisingly, though, the NPRS correlated more with WOSI than OSS....

  15. Histopathologic composition of cerebral thrombi of acute stroke patients is correlated with stroke subtype and thrombus attenuation.

    Directory of Open Access Journals (Sweden)

    Joris M Niesten

    Full Text Available INTRODUCTION: We related composition of cerebral thrombi to stroke subtype and attenuation on non-contrast CT (NCCT to gain more insight in etiopathogenesis and to validate thrombus attenuation as a new imaging biomarker for acute stroke. METHODS: We histopathologically investigated 22 thrombi retrieved after mechanical thrombectomy in acute stroke patients. First, thrombi were classified as fresh, lytic or organized. Second, percentages of red blood cells (RBCs, platelets and fibrin and number of red, white (respectively RBCs or platelets outnumbering other components with ≥ 15% or mixed thrombi were compared between large artery atherosclerosis (LAA, cardioembolism, dissection and unknown subtype. Third, correlation between attenuation and RBCs, platelets and fibrin was calculated using Pearson's correlation coefficients (r. RESULTS: Thrombi were fresh in 73% (n = 16, lytic in 18% (n = 4 and organized in 9% (n = 2. The stroke cause was LAA in eight (36%, cardioembolism in six (27%, dissection in three (14%, and unknown in five (23% patients. LAA thrombi showed the highest percentage RBCs (median 50 (range 35-90, followed by dissection (35 (20-40, p = 0.05, cardioembolism (35 (5-45, p = 0.013 and unknown subtype (25 (2-40, p = 0.006. No differences in platelets (p = 0.16 and fibrin (p = 0.52 between subtypes were found. LAA thrombi were classified as red or mixed (both n = 4, cardioembolisms as mixed (n = 5 or white (n = 1 and dissection as mixed (n = 3. There was a moderate positive correlation between attenuation and RBCs (r = 0.401, p = 0.049, and weak negative correlations with platelets (r = -0.368, p = 0.09 and fibrin (r = -0.073, p = 0.75. CONCLUSIONS: The majority of cerebral thrombi is fresh. There are no differences in age of thrombi between subtypes. LAA thrombi have highest percentages RBCs, cardioembolism and unknown subtype lowest. No relationship exists between subtype and platelets or fibrin percentages. We found a

  16. Screening Physical Activity in Family Practice: Validity of the Spanish Version of a Brief Physical Activity Questionnaire.

    Directory of Open Access Journals (Sweden)

    Anna Puig-Ribera

    Full Text Available The use of brief screening tools to identify inactive patients is essential to improve the efficiency of primary care-based physical activity (PA programs. However, the current employment of short PA questionnaires within the Spanish primary care pathway is unclear. This study evaluated the validity of the Spanish version of a Brief Physical Activity Assessment Tool (SBPAAT.A validation study was carried out within the EVIDENT project. A convenience sample of patients (n = 1,184; age 58.9±13.7 years; 60.5% female completed the SBPAAT and the 7-day Physical Activity Recall (7DPAR and, in addition, wore an accelerometer (ActiGraph GT3X for seven consecutive days. Validity was evaluated by measuring agreement, Kappa correlation coefficients, sensitivity and specificity in achieving current PA recommendations with the 7DPAR. Pearson correlation coefficients with the number of daily minutes engaged in moderate and vigorous intensity PA according to the accelerometer were also assessed. Comparison with accelerometer counts, daily minutes engaged in sedentary, light, moderate, and vigorous intensity PA, total daily kilocalories, and total PA and leisure time expenditure (METs-hour-week between the sufficiently and insufficiently active groups identified by SBPAAT were reported.The SBPAAT identified 41.3% sufficiently active (n = 489 and 58.7% insufficiently active (n = 695 patients; it showed moderate validity (k = 0.454, 95% CI: 0.402-0.505 and a specificity and sensitivity of 74.3% and 74.6%, respectively. Validity was fair for identifying daily minutes engaged in moderate (r = 0.215, 95% CI:0.156 to 0.272 and vigorous PA (r = 0.282, 95% CI:0.165 to 0.391. Insufficiently active patients according to the SBPAAT significantly reported fewer counts/minute (-22%, fewer minutes/day of moderate (-11.38 and vigorous PA (-2.69, spent fewer total kilocalories/day (-753, and reported a lower energy cost (METs-hour-week of physical activities globally (-26

  17. Validity and Reliability of the Abbreviated Barratt Impulsiveness Scale in Spanish (BIS-15S)*

    Science.gov (United States)

    Orozco-Cabal, Luis; Rodríguez, Maritza; Herin, David V.; Gempeler, Juanita; Uribe, Miguel

    2010-01-01

    Objective This study determined the validity and reliability of a new, abbreviated version of the Spanish Barratt Impulsiveness Scale (BIS-15S) in Colombian subjects. Method The BIS-15S was tested in non-clinical (n=283) and clinical (n=164) native Spanish-speakers. Intra-scale reliability was calculated using Cronbach’s α, and test-retest reliability was measured with Pearson correlations. Psychometric properties were determined using standard statistics. A factor analysis was performed to determine BIS-15S factor structure. Results 447 subjects participated in the study. Clinical subjects were older and more educated compared to non-clinical subjects. Impulsivity scores were normally distributed in each group. BIS-15S total, motor, non-planning and attention scores were significantly lower in non-clinical vs. clinical subjects. Subjects with substance-related disorders had the highest BIS-15S total scores, followed by subjects with bipolar disorders and bulimia nervosa/binge eating. Internal consistency was 0.793 and test-retest reliability was 0.80. Factor analysis confirmed a three-factor structure (attention, motor, non-planning) accounting for 47.87% of the total variance in BIS-15S total scores. Conclusions The BIS-15S is a valid and reliable self-report measure of impulsivity in this population. Further research is needed to determine additional components of impulsivity not investigated by this measure. PMID:21152412

  18. The reliability and validity of radiographic measurements for determining the three-dimensional position of the talus in varus and valgus osteoarthritic ankles

    Energy Technology Data Exchange (ETDEWEB)

    Nosewicz, Tomasz L. [Kantonsspital Liestal, Department of Orthopaedic Surgery and Traumatology, Liestal (Switzerland); Academic Medical Center, Department of Orthopaedic Surgery, Meibergdreef 9, AZ, Amsterdam (Netherlands); Knupp, Markus; Bolliger, Lilianna; Hintermann, Beat [Kantonsspital Liestal, Department of Orthopaedic Surgery and Traumatology, Liestal (Switzerland)

    2012-12-15

    To assess the most accurate radiographic method to determine talar three-dimensional position in varus and valgus osteoarthritic ankles, we evaluated the reliability and validity of different radiographic measurements. Nine radiographic measurements were performed blindly on weight-bearing mortise, sagittal, and horizontal radiographs of 33 varus and 33 valgus feet (63 patients). Intra- and interobserver reliability was determined with the intraclass coefficient (ICC). Discriminant validity of measurements between varus and valgus feet was assessed with effect size (ES). Convergent validity (Pearson's r) was evaluated by correlating measurements to the dichotomized varus and valgus groups. Obtained measurements in both groups were finally compared with each other and with 30 control feet. Reliability was excellent (ICC > 0.80) in all but two measurements. Whereas frontal plane validity was excellent (ES and r > 0.80), horizontal and sagittal measurements showed poor to moderate validity (ES and r between 0.00 and 0.60). Four measurements were significantly different among all groups (p < 0.05). Talar positional tendency was found towards dorsiflexion or endorotation in the varus group and towards plantarflexion or exorotation in the valgus group. The frontal tibiotalar surface angle, sagittal talocalcaneal inclination angle, and horizontal talometatarsal I angle showed the best reliability, validity, and difference among the groups. The frontal tibiotalar surface angle, sagittal talocalcaneal inclination angle, and horizontal talometatarsal I angle accurately determine talar three-dimensional radiographic position in weight-bearing varus and valgus osteoarthritic ankles. Careful radiographic evaluation is important, as these deformities affect talar position in all three planes. (orig.)

  19. The reliability and validity of radiographic measurements for determining the three-dimensional position of the talus in varus and valgus osteoarthritic ankles

    International Nuclear Information System (INIS)

    Nosewicz, Tomasz L.; Knupp, Markus; Bolliger, Lilianna; Hintermann, Beat

    2012-01-01

    To assess the most accurate radiographic method to determine talar three-dimensional position in varus and valgus osteoarthritic ankles, we evaluated the reliability and validity of different radiographic measurements. Nine radiographic measurements were performed blindly on weight-bearing mortise, sagittal, and horizontal radiographs of 33 varus and 33 valgus feet (63 patients). Intra- and interobserver reliability was determined with the intraclass coefficient (ICC). Discriminant validity of measurements between varus and valgus feet was assessed with effect size (ES). Convergent validity (Pearson's r) was evaluated by correlating measurements to the dichotomized varus and valgus groups. Obtained measurements in both groups were finally compared with each other and with 30 control feet. Reliability was excellent (ICC > 0.80) in all but two measurements. Whereas frontal plane validity was excellent (ES and r > 0.80), horizontal and sagittal measurements showed poor to moderate validity (ES and r between 0.00 and 0.60). Four measurements were significantly different among all groups (p < 0.05). Talar positional tendency was found towards dorsiflexion or endorotation in the varus group and towards plantarflexion or exorotation in the valgus group. The frontal tibiotalar surface angle, sagittal talocalcaneal inclination angle, and horizontal talometatarsal I angle showed the best reliability, validity, and difference among the groups. The frontal tibiotalar surface angle, sagittal talocalcaneal inclination angle, and horizontal talometatarsal I angle accurately determine talar three-dimensional radiographic position in weight-bearing varus and valgus osteoarthritic ankles. Careful radiographic evaluation is important, as these deformities affect talar position in all three planes. (orig.)

  20. Correlation of Cognitive Abilities Level, Age and Ranks in Judo

    Directory of Open Access Journals (Sweden)

    Kraček Stanislav

    2016-11-01

    Full Text Available The aim of this paper is to ascertain the correlation between selected cognitive abilities, age and performance of judokas according to ranking. The study group consisted of judokas in the age group 18 ± 2.4 years. The Stroop Color-Word Test - Victoria Version (VST was the instrument used to determine the level of cognitive abilities. The data obtained were measured by the Pearson Correlation (r correlation test. The results of the study show an associative relationship of indirect correlation (p < 0.01 between age and all of the three categories of the Stroop test. This is an indirect correlation, so the higher the age, the lower the time (better performance of the probands in the Stroop test. There was no statistically significant correlation between performance in the categories of the Stroop test and rankings. The outcomes show that the level of selected cognitive abilities depends on age, but the level of the selected cognitive abilities does not affect the ranking of the judokas.

  1. Validity studies among hierarchical methods of cluster analysis using cophenetic correlation coefficient

    International Nuclear Information System (INIS)

    Carvalho, Priscilla R.; Munita, Casimiro S.; Lapolli, André L.

    2017-01-01

    The literature presents many methods for partitioning of data base, and is difficult choose which is the most suitable, since the various combinations of methods based on different measures of dissimilarity can lead to different patterns of grouping and false interpretations. Nevertheless, little effort has been expended in evaluating these methods empirically using an archaeological data base. In this way, the objective of this work is make a comparative study of the different cluster analysis methods and identify which is the most appropriate. For this, the study was carried out using a data base of the Archaeometric Studies Group from IPEN-CNEN/SP, in which 45 samples of ceramic fragments from three archaeological sites were analyzed by instrumental neutron activation analysis (INAA) which were determinate the mass fraction of 13 elements (As, Ce, Cr, Eu, Fe, Hf, La, Na, Nd, Sc, Sm, Th, U). The methods used for this study were: single linkage, complete linkage, average linkage, centroid and Ward. The validation was done using the cophenetic correlation coefficient and comparing these values the average linkage method obtained better results. A script of the statistical program R with some functions was created to obtain the cophenetic correlation. By means of these values was possible to choose the most appropriate method to be used in the data base. (author)

  2. Validity studies among hierarchical methods of cluster analysis using cophenetic correlation coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Priscilla R.; Munita, Casimiro S.; Lapolli, André L., E-mail: prii.ramos@gmail.com, E-mail: camunita@ipen.br, E-mail: alapolli@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The literature presents many methods for partitioning of data base, and is difficult choose which is the most suitable, since the various combinations of methods based on different measures of dissimilarity can lead to different patterns of grouping and false interpretations. Nevertheless, little effort has been expended in evaluating these methods empirically using an archaeological data base. In this way, the objective of this work is make a comparative study of the different cluster analysis methods and identify which is the most appropriate. For this, the study was carried out using a data base of the Archaeometric Studies Group from IPEN-CNEN/SP, in which 45 samples of ceramic fragments from three archaeological sites were analyzed by instrumental neutron activation analysis (INAA) which were determinate the mass fraction of 13 elements (As, Ce, Cr, Eu, Fe, Hf, La, Na, Nd, Sc, Sm, Th, U). The methods used for this study were: single linkage, complete linkage, average linkage, centroid and Ward. The validation was done using the cophenetic correlation coefficient and comparing these values the average linkage method obtained better results. A script of the statistical program R with some functions was created to obtain the cophenetic correlation. By means of these values was possible to choose the most appropriate method to be used in the data base. (author)

  3. Can Twitter Be a Source of Information on Allergy? Correlation of Pollen Counts with Tweets Reporting Symptoms of Allergic Rhinoconjunctivitis and Names of Antihistamine Drugs.

    Science.gov (United States)

    Gesualdo, Francesco; Stilo, Giovanni; D'Ambrosio, Angelo; Carloni, Emanuela; Pandolfi, Elisabetta; Velardi, Paola; Fiocchi, Alessandro; Tozzi, Alberto E

    2015-01-01

    Pollen forecasts are in use everywhere to inform therapeutic decisions for patients with allergic rhinoconjunctivitis (ARC). We exploited data derived from Twitter in order to identify tweets reporting a combination of symptoms consistent with a case definition of ARC and those reporting the name of an antihistamine drug. In order to increase the sensitivity of the system, we applied an algorithm aimed at automatically identifying jargon expressions related to medical terms. We compared weekly Twitter trends with National Allergy Bureau weekly pollen counts derived from US stations, and found a high correlation of the sum of the total pollen counts from each stations with tweets reporting ARC symptoms (Pearson's correlation coefficient: 0.95) and with tweets reporting antihistamine drug names (Pearson's correlation coefficient: 0.93). Longitude and latitude of the pollen stations affected the strength of the correlation. Twitter and other social networks may play a role in allergic disease surveillance and in signaling drug consumptions trends.

  4. Performance of a cognitive load inventory during simulated handoffs: Evidence for validity.

    Science.gov (United States)

    Young, John Q; Boscardin, Christy K; van Dijk, Savannah M; Abdullah, Ruqayyah; Irby, David M; Sewell, Justin L; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-01-01

    Advancing patient safety during handoffs remains a public health priority. The application of cognitive load theory offers promise, but is currently limited by the inability to measure cognitive load types. To develop and collect validity evidence for a revised self-report inventory that measures cognitive load types during a handoff. Based on prior published work, input from experts in cognitive load theory and handoffs, and a think-aloud exercise with residents, a revised Cognitive Load Inventory for Handoffs was developed. The Cognitive Load Inventory for Handoffs has items for intrinsic, extraneous, and germane load. Students who were second- and sixth-year students recruited from a Dutch medical school participated in four simulated handoffs (two simple and two complex cases). At the end of each handoff, study participants completed the Cognitive Load Inventory for Handoffs, Paas' Cognitive Load Scale, and one global rating item for intrinsic load, extraneous load, and germane load, respectively. Factor and correlational analyses were performed to collect evidence for validity. Confirmatory factor analysis yielded a single factor that combined intrinsic and germane loads. The extraneous load items performed poorly and were removed from the model. The score from the combined intrinsic and germane load items associated, as predicted by cognitive load theory, with a commonly used measure of overall cognitive load (Pearson's r = 0.83, p load during handoffs may be measured via a self-report measure. Additional work is required to develop an adequate measure of extraneous load.

  5. The correlation of in vivo and ex vivo tissue dielectric properties to validate electromagnetic breast imaging: initial clinical experience

    International Nuclear Information System (INIS)

    Halter, Ryan J; Zhou, Tian; Meaney, Paul M; Hartov, Alex; Barth, Richard J Jr; Rosenkranz, Kari M; Wells, Wendy A; Kogel, Christine A; Borsic, Andrea; Rizzo, Elizabeth J; Paulsen, Keith D

    2009-01-01

    Electromagnetic (EM) breast imaging provides low-cost, safe and potentially a more specific modality for cancer detection than conventional imaging systems. A primary difficulty in validating these EM imaging modalities is that the true dielectric property values of the particular breast being imaged are not readily available on an individual subject basis. Here, we describe our initial experience in seeking to correlate tomographic EM imaging studies with discrete point spectroscopy measurements of the dielectric properties of breast tissue. The protocol we have developed involves measurement of in vivo tissue properties during partial and full mastectomy procedures in the operating room (OR) followed by ex vivo tissue property recordings in the same locations in the excised tissue specimens in the pathology laboratory immediately after resection. We have successfully applied all of the elements of this validation protocol in a series of six women with cancer diagnoses. Conductivity and permittivity gauged from ex vivo samples over the frequency range 100 Hz–8.5 GHz are found to be similar to those reported in the literature. A decrease in both conductivity and permittivity is observed when these properties are gauged from ex vivo samples instead of in vivo. We present these results in addition to a case study demonstrating how discrete point spectroscopy measurements of the tissue can be correlated and used to validate EM imaging studies

  6. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) in Persian Speaking Patients with Knee Osteoarthritis.

    Science.gov (United States)

    Ebrahimzadeh, Mohammad H; Makhmalbaf, Hadi; Birjandinejad, Ali; Keshtan, Farideh Golhasani; Hoseini, Hosein A; Mazloumi, Seyed Mahdi

    2014-03-01

    Osteoarthritis of the knee is the most common chronic joint disease that involves middle aged and elderly persons. There are different clinical instruments to quantify the health status of patients with knee osteoarthritis and one example is the WOMAC score that has been translated and adapted into different languages. The purpose of this study was cultural adaptation, validation and reliability testing of the Persian version of the WOMAC index in Iranians with knee osteoarthritis. We translated the original WOMAC questionnaire into Persian by the forward and backward technique, and then its psychometric study was done on 169 native Persian speaking patients with knee degenerative joint disease. Mean age of patients was 53.9 years. The SF-36 and KOOS were used to assess construct validity. Reliability testing resulted in a Cronbach's alpha of 0.917, showing the internal consistency of the questionnaire to be a reliable tool. Inter-correlation matrix among different scales of the Persian WOMAC index yielded a highly significant correlation between all subscales including stiffness, pain, and physical function. In terms of validity, Pearson`s correlation coefficient was significant between three domains of the WOMAC with PF, RP, BP, GH, VT, and PCS dimensions of the SF-36 health survey (P<0.005) and KOOS (P<0.0001) . The Persian WOMAC index is a valid and reliable patient- reported clinical instrument for knee osteoarthritis.

  7. Validity and Reliability of a Wearable Inertial Sensor to Measure Velocity and Power in the Back Squat and Bench Press.

    Science.gov (United States)

    Orange, Samuel T; Metcalfe, James W; Liefeith, Andreas; Marshall, Phil; Madden, Leigh A; Fewster, Connor R; Vince, Rebecca V

    2018-05-08

    Orange, ST, Metcalfe, JW, Liefeith, A, Marshall, P, Madden, LA, Fewster, CR, and Vince, RV. Validity and reliability of a wearable inertial sensor to measure velocity and power in the back squat and bench press. J Strength Cond Res XX(X): 000-000, 2018-This study examined the validity and reliability of a wearable inertial sensor to measure velocity and power in the free-weight back squat and bench press. Twenty-nine youth rugby league players (18 ± 1 years) completed 2 test-retest sessions for the back squat followed by 2 test-retest sessions for the bench press. Repetitions were performed at 20, 40, 60, 80, and 90% of 1 repetition maximum (1RM) with mean velocity, peak velocity, mean power (MP), and peak power (PP) simultaneously measured using an inertial sensor (PUSH) and a linear position transducer (GymAware PowerTool). The PUSH demonstrated good validity (Pearson's product-moment correlation coefficient [r]) and reliability (intraclass correlation coefficient [ICC]) only for measurements of MP (r = 0.91; ICC = 0.83) and PP (r = 0.90; ICC = 0.80) at 20% of 1RM in the back squat. However, it may be more appropriate for athletes to jump off the ground with this load to optimize power output. Further research should therefore evaluate the usability of inertial sensors in the jump squat exercise. In the bench press, good validity and reliability were evident only for the measurement of MP at 40% of 1RM (r = 0.89; ICC = 0.83). The PUSH was unable to provide a valid and reliable estimate of any other criterion variable in either exercise. Practitioners must be cognizant of the measurement error when using inertial sensor technology to quantify velocity and power during resistance training, particularly with loads other than 20% of 1RM in the back squat and 40% of 1RM in the bench press.

  8. Psychometric Properties of the Persian Version of Parenting Style and Dimensions Questionnaire: Application for Children`s Health-related Behaviors

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Morowatisharifabad

    2016-09-01

    Full Text Available Background: Parenting style is associated with children's health-related behaviors. One of the popularity and applicability assessment tools is Parenting Style and Dimensions Questionnaire (PSDQ that the lack of Iranian version can be seen.This study was conducted to determine the validity and reliability of Iranian version of PSDQ.Materials and Methods: This study was done with randomized cluster sampling on 588 parents. Cronbach's α coefficient was used to determine the internal consistency and Pearson`s correlation coefficients was used for test-retest reliability and the construct validity. Conformity factor analysis was also applied to determine the construct validity. Results: Cronbach's α coefficient for two authoritative and authoritarian styles with the highest estimated value were 0.86 and it was 0.41 for permissive style. The results of the correlation test in all three afore mentioned styles were significant. Correlation coefficients between authoritative style and its subscales were about 0.86 to 0.89 and between authoritarian style and its subscales were about 0.81 to 0.87. Confirmatory factor analysis showed that goodness-of-fit indices, including CMIN/DF,GFI, CFI, IFI and RMSEA, were 2.1, 0.91, 0.90, 0.90, and 0.04, respectively, which indicated a good the construct validity of instrument.Conclusion: The PSDQ that has been translated into Persian obtained good reliability and validity. PSDQ questionnaire can be considered a useful tool in the assessments and interventions concerning parenting styles used in Iran.

  9. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC in Persian Speaking Patients with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Mohammad H Ebrahimzadeh

    2014-03-01

    Full Text Available Background: Osteoarthritis of the knee is the most common chronic joint disease that involves middle aged and elderly persons. There are different clinical instruments to quantify the health status of patients with knee osteoarthritis and one example is the WOMAC score that has been translated and adapted into different languages. The purpose of this study was cultural adaptation, validation and reliability testing of the Persian version of the WOMAC index in Iranians with knee osteoarthritis.   Methods: We translated the original WOMAC questionnaire into Persian by the forward and backward technique, and then its psychometric study was done on 169 native Persian speaking patients with knee degenerative joint disease. Mean age of patients was 53.9 years. The SF-36 and KOOS were used to assess construct validity. Results: Reliability testing resulted in a Cronbach’s alpha of 0.917, showing the internal consistency of the questionnaire to be a reliable tool. Inter-correlation matrix among different scales of the Persian WOMAC index yielded a highly significant correlation between all subscales including stiffness, pain, and physical function. In terms of validity, Pearson`s correlation coefficient was significant between three domains of the WOMAC with PF, RP, BP, GH, VT, and PCS dimensions of the SF-36 health survey (P

  10. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC in Persian Speaking Patients with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Mohammad H Ebrahimzadeh

    2014-03-01

    Full Text Available   Background: Osteoarthritis of the knee is the most common chronic joint disease that involves middle aged and elderly persons. There are different clinical instruments to quantify the health status of patients with knee osteoarthritis and one example is the WOMAC score that has been translated and adapted into different languages. The purpose of this study was cultural adaptation, validation and reliability testing of the Persian version of the WOMAC index in Iranians with knee osteoarthritis.   Methods: We translated the original WOMAC questionnaire into Persian by the forward and backward technique, and then its psychometric study was done on 169 native Persian speaking patients with knee degenerative joint disease. Mean age of patients was 53.9 years. The SF-36 and KOOS were used to assess construct validity. Results: Reliability testing resulted in a Cronbach’s alpha of 0.917, showing the internal consistency of the questionnaire to be a reliable tool. Inter-correlation matrix among different scales of the Persian WOMAC index yielded a highly significant correlation between all subscales including stiffness, pain, and physical function. In terms of validity, Pearson`s correlation coefficient was significant between three domains of the WOMAC with PF, RP, BP, GH, VT, and PCS dimensions of the SF-36 health survey (P

  11. Spanish translation, adaptation and validation of the Hypoglycemia Fear Survey in adults with type 1 diabetes in the Community of Madrid.

    Science.gov (United States)

    Tasende, Clara; Rubio, José Antonio; Álvarez, Julia

    2018-05-01

    The negative impact of hypoglycemia on patients with type 1 diabetes mellitus (T1DM) may lead to development of fear of hypoglycemia. In this study, the original Hypoglycemia Fear Survey (HFS) questionnaire was translated into Spanish, adapted and validated, and variables associated to fear of hypoglycemia in T1DM were analyzed. The HFS was translated and adapted to Spanish using the forward-backward translation method. The resulting questionnaire, EsHFS, was administrated to a population with T1DM. The following parameters of the questionnaire were analyzed: feasibility, reliability (Cronbach's alpha), content validity (correlating EsHFS and EsDQOL [Diabetes Quality of Life] questionnaire), and stability (by means of test-retest correlation). The EsHFS questionnaire consists of 24 items and three subscales including: subscale 1 on worry; subscale 2 on hypoglycemia-avoidant behavior, and subscale 3 on hyperglycemia-influenced behavior. 163 subjects, with a mean aged (SD) of 36 (10.5) years, 24% on continuous subcutaneous insulin infusion. Of these, 99.8% completed the EsHFS questionnaire in less than 10minutes. Cronbach's alpha for global EsHFS was 0.92. EsHFS and its subscales correlated with EsDQOL. Test-retest correlation (Pearson) was r=0.92. Age, female sex, lower educational level, living alone, frequency of daily self-monitoring and non-severe hypoglycemia, and history of severe and/or asymptomatic hypoglycemia were independently associated to the result of EsHFS. The Spanish version of the HFS, EsHFS, has good psychometric properties and may be a useful tool to assess fear of hypoglycemia in Spanish-speaking patients with T1DM. Copyright © 2018 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

    Science.gov (United States)

    Kim, Mock Ryeon; Park, Hye Won; Son, Jae Sung; Lee, Ran

    2016-01-01

    Purpose To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was 0.68±0.18 g/kg/d; according to age, the dose was 0.73±0.16 g/kg/d (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation. PMID:27738600

  13. Cross-cultural adaptation, reliability and validity of the Turkish version of the Lower Limb Functional Index.

    Science.gov (United States)

    Duruturk, Neslihan; Tonga, Eda; Gabel, Charles Philip; Acar, Manolya; Tekindal, Agah

    2015-07-26

    This study aims to adapt culturally a Turkish version of the Lower Limb Functional Index (LLFI) and to determine its validity, reliability, internal consistency, measurement sensitivity and factor structure in lower limb problems. The LLFI was translated into Turkish and cross-culturally adapted with a double forward-backward protocol that determined face and content validity. Individuals (n = 120) with lower limb musculoskeletal disorders completed the LLFI and Short Form-36 questionnaires and the Timed Up and Go physical test. The psychometric properties were evaluated for the all participants from patient-reported outcome measures made at baseline and repeated at day 3 to determine criterion between scores (Pearson's r), internal consistency (Cronbachs α) and test-retest reliability (intraclass correlation coefficient - ICC 2.1 ). Error was determined using standard error of the measurement (SEM) and minimal detectable change at the 90% level (MDC 90 ), while factor structure was determined using exploratory factor analysis with maximum likelihood extraction and Varimax rotation. The psychometric characteristics showed strong criterion validity (r = 0.74-0.76), high internal consistency (α = 0.82) and high test-retest reability (ICC 2.1  = 0.97). The SEM of 3.2% gave an MDC 90  = 5.8%. The factor structure was uni-dimensional. Turkish version of LLFI was found to be valid and reliable for the measurement of lower limb function in a Turkish population. Implications for Rehabilitation Lower extremity musculoskeletal disorders are common and greatly impact activities among the affected individuals pertaining to daily living, work, leisure and quality of life. Patient-reported outcome (PRO) measures have advantages as they are practical, cost-effective and clinically convenient for use in patient-centered care. The Lower Limb Functional Index is a recently validated PRO measure shown to have strong clinimetric properties.

  14. Cross-cultural validation of the Persian version of the Functional Independence Measure for patients with stroke.

    Science.gov (United States)

    Naghdi, Soofia; Ansari, Noureddin Nakhostin; Raji, Parvin; Shamili, Aryan; Amini, Malek; Hasson, Scott

    2016-01-01

    To translate and cross-culturally adapt the Functional Independence Measure (FIM) into the Persian language and to test the reliability and validity of the Persian FIM (PFIM) in patients with stroke. In this cross-sectional study carried out in an outpatient stroke rehabilitation center, 40 patients with stroke (mean age 60 years) were participated. A standard forward-backward translation method and expert panel validation was followed to develop the PFIM. Two experienced occupational therapists (OTs) assessed the patients independently in all items of the PFIM in a single session for inter-rater reliability. One of the OTs reassessed the patients after 1 week for intra-rater reliability. There were no floor or ceiling effects for the PFIM. Excellent inter-rater and intra-rater reliability was noted for the PFIM total score, motor and cognitive subscales (ICC(agreement)0.88-0.98). According to the Bland-Altman agreement analysis, there was no systematic bias between raters and within raters. The internal consistency of the PFIM was with Cronbach's alpha from 0.70 to 0.96. The principal component analysis with varimax rotation indicated a three-factor structure: (1) self-care and mobility; (2) sphincter control and (3) cognitive that jointly accounted for 74.8% of the total variance. Construct validity was supported by a significant Pearson correlation between the PFIM and the Persian Barthel Index (r = 0.95; p Persian patients with stroke. The Functional Independence Measure (FIM) is an outcome measure for disability based on the International Classification of Functioning, Disability and Health (ICF). The FIM was cross-culturally adapted and validated into Persian language. The Persian version of the FIM (PFIM) is reliable and valid for assessing functional status of patients with stroke. The PFIM can be used in Persian speaking countries to assess the limitations in activities of daily living of patients with stroke.

  15. Validation of a global satellite rainfall product for real time monitoring of meteorological extremes

    Science.gov (United States)

    Cánovas-García, Fulgencio; García-Galiano, Sandra; Karbalaee, Negar

    2017-10-01

    The real time monitoring of storms is important for the management and prevention of flood risks. However, in the southeast of Spain, it seems that the density of the rain gauge network may not be sufficient to adequately characterize the rainfall spatial distribution or the high rainfall intensities that are reached during storms. Satellite precipitation products such as PERSIANN-CCS (Precipitation Estimation from Remotely Sensed Information using Artificial Neural Networks - Cloud Classification System) could be used to complement the automatic rain gauge networks and so help solve this problem. However, the PERSIANN-CCS product has only recently become available, so its operational validity for areas such as south-eastern Spain is not yet known. In this work, a methodology for the hourly validation of PERSIANN-CCS is presented. We used the rain gauge stations of the SIAM (Sistema de Información Agraria de Murcia) network to study three storms with a very high return period. These storms hit the east and southeast of the Iberian Peninsula and resulted in the loss of human life, major damage to agricultural crops and a strong impact on many different types of infrastructure. The study area is the province of Murcia (Region of Murcia), located in the southeast of the Iberian Peninsula, covering an area of more than 11,000 km2 and with a population of almost 1.5 million. In order to validate the PERSIANN-CCS product for these three storms, contrasts were made with the hyetographs registered by the automatic rain gauges, analyzing statistics such as bias, mean square difference and Pearson's correlation coefficient. Although in some cases the temporal distribution of rainfall was well captured by PERSIANN-CCS, in several rain gauges high intensities were not properly represented. The differences were strongly correlated with the rain gauge precipitation, but not with satellite-obtained rainfall. The main conclusion concerns the need for specific local calibration

  16. Correlation between three color coordinates of human teeth

    Science.gov (United States)

    Lee, Yong-Keun

    2014-11-01

    The objective was to determine whether there were significant correlations in the three color coordinates within each of two color coordinate systems, such as the Commission Internationale de l'Eclairage (CIE) L*a*b* system, and the lightness, chroma, and hue angle system, of human vital teeth. The color of six maxillary and six mandibular anterior teeth was measured by the Shade Vision System. Pearson correlations between each pair of the color coordinates were determined (α=0.01). The influence of two color coordinates on the other color coordinate was determined with a multiple regression analysis (α=0.01). Based on correlation analyses, all the color coordinate pairs showed significant correlations except for the chroma and hue angle pair. The CIE L* was negatively correlated with the CIE a*, b*, and chroma, but positively correlated with the hue angle. The CIE a* was positively correlated with the CIE b* and chroma. Tooth color coordinates were correlated each other. Lighter teeth were less chromatic both in the CIE a* and b* coordinates. Therefore, it was postulated that the three color coordinates of human teeth were harmonized within certain color attribute ranges, and a lack of correlations in these coordinates might indicate external/internal discolorations and/or anomalies of teeth.

  17. Repositioning academic libraries for the achievement of National ...

    African Journals Online (AJOL)

    Instrument was validated by three experts in the Department of Library and Information Science and Measurement and Evaluation. Reliability was done by test retest method using Pearson Product Moment Correlation Coefficient ® which yielded an index of 0.78. Both the research questions and hypotheses were answered ...

  18. Parental marital status and peer influence as corelates of teenage ...

    African Journals Online (AJOL)

    The study examined the effects of parental marital status and peer influence on the occurrence of teenage pregnancy among 324 female teens in south-south, Nigeria. The participants responded to a valid scale. The Pearson correlation and Multiple Regression procedures were used to investigate the predictive capacity of ...

  19. Validity Study of a Jump Mat Compared to the Reference Standard Force Plate.

    Science.gov (United States)

    Rogan, Slavko; Radlinger, Lorenz; Imhasly, Caroline; Kneubuehler, Andrea; Hilfiker, Roger

    2015-12-01

    In the field of vertical jump diagnostics, force plates (FP) are the reference standard. Recently, despite a lack of evidence, jump mats have been used increasingly. Important factors in favor of jumping mats are their low cost and portability. This validity study compared the Haynl-Elektronik jump mat (HE jump mat) with the reference standard force plate. Ten healthy volunteers participated and each participant completed three series of five drop jumps (DJ). The parameters ground contact time (GCT) and vertical jump height (VJH) from the HE jump mat and the FP were used to evaluate the concurrent validity. The following statistical calculations were performed: Pearson's correlation (r), Bland-Altman plots (standard and for adjusted trend), and regression equations. The Bland-Altman plots suggest that the HE jump mat measures shorter contact times and higher jump heights than the FP. The trend-adjusted Bland-Altman plot shows higher mean differences and wider wing-spreads of confidence limits during longer GCT. During the VJH the mean differences and the wing-spreads of the confidence limits throughout the range present as relatively constant. The following regression equations were created, as close as possible to the true value: GCT = 5.920385 + 1.072293 × [value HE jump mat] and VJH = -1.73777 + 1.011156 × [value HE jump mat]. The HE jump mat can be recommended in relation to the validity of constraints. In this study, only a part of the quality criteria were examined. For the final recommendation it is advised to examine the HE jump mat on the other quality criteria (test-retest reliability, sensitivity change).

  20. Psychometric validation of patient-reported outcome measures assessing chronic constipation

    Directory of Open Access Journals (Sweden)

    Nelson LM

    2014-09-01

    Full Text Available Lauren M Nelson,1 Valerie SL Williams,1 Sheri E Fehnel,1 Robyn T Carson,2 James MacDougall,3 Mollie J Baird,3 Stavros Tourkodimitris,2 Caroline B Kurtz,3 Jeffrey M Johnston31RTI Health Solutions, Durham, NC, USA; 2Forest Research Institute, Jersey City, NJ, USA; 3Ironwood Pharmaceuticals, Cambridge, MA, USABackground: Measures assessing treatment outcomes in previous CC clinical trials have not met the requirements described in the US Food and Drug Administration's guidance on patient-reported outcomes.Aim: Psychometric analyses using data from one Phase IIb study and two Phase III trials of linaclotide for the treatment of chronic constipation (CC were conducted to document the measurement properties of patient-reported CC Symptom Severity Measures.Study methods: Each study had a multicenter, randomized, double-blind, placebo-controlled, parallel-group design, comparing placebo to four doses of oral linaclotide taken once daily for 4 weeks in the Phase IIb dose-ranging study (n=307 and to two doses of linaclotide taken once daily for 12 weeks in the Phase III trials (n=1,272. The CC Symptom Severity Measures addressing bowel function (Bowel Movement Frequency, Stool Consistency, Straining and abdominal symptoms (Bloating, Abdominal Discomfort, Abdominal Pain were administered daily using interactive voice-response system technology. Intraclass correlations, Pearson correlations, factor analyses, F-tests, and effect sizes were computed.Results: The CC Symptom Severity Measures demonstrated satisfactory test–retest reliability and construct validity. Factor analyses indicated one factor for abdominal symptoms and another for bowel symptoms. Known-groups F-tests substantiated the discriminating ability of the CC Symptom Severity Measures. Responsiveness statistics were moderate to strong, indicating that these measures are capable of detecting change.Conclusion: In large studies of CC patients, linaclotide significantly improved abdominal and

  1. Validitas dan Reliabilitas Konstruk Pengukuran Perpustakaan Ideal Berbasis Pemakai dengan Pendekatan LIBQUAL

    Directory of Open Access Journals (Sweden)

    Yulyanti Fahruna

    2017-08-01

    Full Text Available This study aims to measure the validity and reliability construct satisfaction and quality of library services based on the user using LIBQUAL (library quality method with a touch of marketing management. Data analysis by Cronbach Alpha and Pearson Correlation. The research was conducted in Tanjungpura University (UNTAN by taking samples of visitors (students at six (6 faculty libraries namely three (3 social faculty of 150 people and three (3 science faculty of 150 people. The sample is chosen by purposive sampling method. Reliability test results show that the five US, IC, LP, LQ and KU variables show high instrument reliability. The result of pearson correlation test shows that the measurement instrument used has problem validity on some question items. At minimum service item with correlation value smaller than 0.30 is IC2, IC5 and LQ5 so it is declared invalid. At service expectation items with correlation value smaller than 0.30 ie AS8, IC1, IC2, IC4, LP1, KU1, KU2, KU4, and KU8. And at present service items with correlation values smaller than 0.30 ie IC1, IC3, LP1, LP3, LQ1, LQ3, LQ4 and KU1.

  2. Content of alpha-linolenic acid in human atrial tissue correlates with plasma levels of alpha-linolenic acid

    DEFF Research Database (Denmark)

    Gu, Jiwei; Eschen, Rikke Bülow; Andreasen, Annette

    and ALA levels were compared by the Pearson correlation coefficient. Results: There was a statistical significant correlation (r=0.54, 95% confidence interval: 0.30-0.71) between levels of ALA in plasma phospholipids and atrial tissue. Conclusion: The content of ALA in plasma phospholipids is a short term...... indicator of intake of ALA and this correlated well with the content of ALA in atrial tissue. Atrial tissue is not readily available but this study shows that determination of plasma phospholipids may be useful to further investigate an antiarrhythmic effect of ALA on AF....

  3. Validation of the American Board of Orthodontics Objective Grading System for assessing the treatment outcomes of Chinese patients.

    Science.gov (United States)

    Song, Guang-Ying; Baumrind, Sheldon; Zhao, Zhi-He; Ding, Yin; Bai, Yu-Xing; Wang, Lin; He, Hong; Shen, Gang; Li, Wei-Ran; Wu, Wei-Zi; Ren, Chong; Weng, Xuan-Rong; Geng, Zhi; Xu, Tian-Min

    2013-09-01

    Orthodontics in China has developed rapidly, but there is no standard index of treatment outcomes. We assessed the validity of the American Board of Orthodontics Objective Grading System (ABO-OGS) for the classification of treatment outcomes in Chinese patients. We randomly selected 108 patients who completed treatment between July 2005 and September 2008 in 6 orthodontic treatment centers across China. Sixty-nine experienced Chinese orthodontists made subjective assessments of the end-of-treatment casts for each patient. Three examiners then used the ABO-OGS to measure the casts. Pearson correlation analysis and receiver operating characteristic curve analysis were conducted to evaluate the correspondence between the ABO-OGS cast measurements and the orthodontists' subjective assessments. The average subjective grading scores were highly correlated with the ABO-OGS scores (r = 0.7042). Four of the 7 study cast components of the ABO-OGS score-occlusal relationship, overjet, interproximal contact, and alignment-were statistically significantly correlated with the judges' subjective assessments. Together, these 4 accounted for 58% of the variability in the average subjective grading scores. The ABO-OGS cutoff score for cases that the judges deemed satisfactory was 16 points; the corresponding cutoff score for cases that the judges considered acceptable was 21 points. The ABO-OGS is a valid index for the assessment of treatment outcomes in Chinese patients. By comparing the objective scores on this modification of the ABO-OGS with the mean subjective assessment of a panel of highly qualified Chinese orthodontists, a cutoff point for satisfactory treatment outcome was defined as 16 points or fewer, with scores of 16 to 21 points denoting less than satisfactory but still acceptable treatment. Cases that scored greater than 21 points were considered unacceptable. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  4. Reliability and Validity of Digital Imagery Methodology for Measuring Starting Portions and Plate Waste from School Salad Bars.

    Science.gov (United States)

    Bean, Melanie K; Raynor, Hollie A; Thornton, Laura M; Sova, Alexandra; Dunne Stewart, Mary; Mazzeo, Suzanne E

    2018-04-12

    Scientifically sound methods for investigating dietary consumption patterns from self-serve salad bars are needed to inform school policies and programs. To examine the reliability and validity of digital imagery for determining starting portions and plate waste of self-serve salad bar vegetables (which have variable starting portions) compared with manual weights. In a laboratory setting, 30 mock salads with 73 vegetables were made, and consumption was simulated. Each component (initial and removed portion) was weighed; photographs of weighed reference portions and pre- and post-consumption mock salads were taken. Seven trained independent raters visually assessed images to estimate starting portions to the nearest ¼ cup and percentage consumed in 20% increments. These values were converted to grams for comparison with weighed values. Intraclass correlations between weighed and digital imagery-assessed portions and plate waste were used to assess interrater reliability and validity. Pearson's correlations between weights and digital imagery assessments were also examined. Paired samples t tests were used to evaluate mean differences (in grams) between digital imagery-assessed portions and measured weights. Interrater reliabilities were excellent for starting portions and plate waste with digital imagery. For accuracy, intraclass correlations were moderate, with lower accuracy for determining starting portions of leafy greens compared with other vegetables. However, accuracy of digital imagery-assessed plate waste was excellent. Digital imagery assessments were not significantly different from measured weights for estimating overall vegetable starting portions or waste; however, digital imagery assessments slightly underestimated starting portions (by 3.5 g) and waste (by 2.1 g) of leafy greens. This investigation provides preliminary support for use of digital imagery in estimating starting portions and plate waste from school salad bars. Results might inform

  5. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    Science.gov (United States)

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  6. IDENTIFICATION OF THE MASS DISTRIBUTIONS OF THE MILK FAT PHASE USING UNIVERSAL PEARSON DISTRIBUTIONS

    Directory of Open Access Journals (Sweden)

    A. A. Khvostov

    2015-01-01

    Full Text Available In this paper we consider the problem of approximating the experimental values of the coefficient of attenuation of ultrasonic oscillations and the mass distribution of the fat globules in the milk and milk products. The analysis of experimental data in terms of the choice of the method of approximation was done. A approximating dependence is based on the solution of Pearson differential equations. The advantages of the proposed method for the type of approximation of the experimental data obtained. An algorithm for constructing a mathematical model describing the relaxation spectrum and mass distribution of the fat globules in the milk and milk products was implemented. As a result, a family of Pearson approximation curves of the experimental data shows the ability to qualitatively correctly describe the change in the distribution of the fat phase in the process of homogenization. It estimates the error of approximating dependence, which amounted to 18 %. It is shown that during of the process of homogenization of dairy products changes shape of the curve describing the distribution of the fat globules, in view of the fact that there is a local extremum, caused by the presence of the non-homogenized fat globules. The accuracy of the selected mathematical model is significantly reduced. At the same time, it loses its physical meaning and its parameters. To address the identified deviations in the proposed mass distribution of fat globules as a function with two modes. It is proved that the complexity of the model is not only doubles the number of its parameters, but also complicates the interpretation of measurement results in a control system, and makes it difficult to analyze the obtained parameters of approximation by decision-maker. As a result of approximation of experimental data suggested to use statistical moments of the distribution for problem decision.

  7. Tinnitus functional index: validation of the German version for Switzerland.

    Science.gov (United States)

    Peter, Nicole; Kleinjung, Tobias; Jeker, Raphael; Meyer, Martin; Klaghofer, Richard; Weidt, Steffi

    2017-05-05

    Different standardized questionnaires are used to assess tinnitus severity, making comparisons across studies difficult. These questionnaires are also used to measure treatment-related changes in tinnitus although they were not designed for this purpose. To solve these problems, a new questionnaire - the Tinnitus Functional Index (TFI) - has been established. The TFI is highly responsive to treatment-related change and promises to be the new gold standard in tinnitus evaluation. The aim of the current study was to validate a German version of the TFI for a German-speaking population in Switzerland. At the ENT department of the University Hospital Zurich, 264 subjects completed an online survey including the German version for Switzerland of TFI, Tinnitus Handicap Inventory (THI), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI) and sociodemographic variables. Internal consistency of the TFI was calculated with Cronbach's alpha coefficient. Pearson correlation coefficients were used for the test-retest reliability of the TFI and to investigate convergent and discriminant validity between the THI and the BDI and BAI, respectively. Factor analysis was assessed using a principal component analysis with oblique rotation. The different factors extracted were then compared with the original questionnaire. The German version of the TFI for Switzerland showed an excellent internal consistency (Cronbach's alpha of 0.97) and an excellent test-retest reliability of 0.91. The convergent validity with THI was high (r = 0.86). The discriminant validity with BAI and BDI showed moderate results (BAI: r = 0.60 and BDI: r = 0.65). In the factor analysis only five factors with one main factor could be extracted instead of eight factors as described in the original version. Nevertheless, relations to the original eight subscales could be demonstrated. The German version of the TFI for Switzerland is a suitable instrument for measuring the impact of tinnitus

  8. Validation of a colour rendering index based on memory colours

    OpenAIRE

    Smet, Kevin; Jost-Boissard, Sophie; Ryckaert, Wouter; Deconinck, Geert; Hanselaer, Peter

    2010-01-01

    In this paper the performance of a colour rendering index based on memory colours is investigated in comparison with the current CIE Colour Rendering Index, the NIST Colour Quality Scale and visual appreciation results obtained at CNRS at Lyon University for a set of 3000K and 4000K LED light sources. The Pearson and Spearman correlation coefficients between each colour rendering metric and the two sets of visual results were calculated. It was found that the memory colour based colour render...

  9. Workload assessment of surgeons: correlation between NASA TLX and blinks.

    Science.gov (United States)

    Zheng, Bin; Jiang, Xianta; Tien, Geoffrey; Meneghetti, Adam; Panton, O Neely M; Atkins, M Stella

    2012-10-01

    Blinks are known as an indicator of visual attention and mental stress. In this study, surgeons' mental workload was evaluated utilizing a paper assessment instrument (National Aeronautics and Space Administration Task Load Index, NASA TLX) and by examining their eye blinks. Correlation between these two assessments was reported. Surgeons' eye motions were video-recorded using a head-mounted eye-tracker while the surgeons performed a laparoscopic procedure on a virtual reality trainer. Blink frequency and duration were computed using computer vision technology. The level of workload experienced during the procedure was reported by surgeons using the NASA TLX. A total of 42 valid videos were recorded from 23 surgeons. After blinks were computed, videos were divided into two groups based on the blink frequency: infrequent group (≤ 6 blinks/min) and frequent group (more than 6 blinks/min). Surgical performance (measured by task time and trajectories of tool tips) was not significantly different between these two groups, but NASA TLX scores were significantly different. Surgeons who blinked infrequently reported a higher level of frustration (46 vs. 34, P = 0.047) and higher overall level of workload (57 vs. 47, P = 0.045) than those who blinked more frequently. The correlation coefficients (Pearson test) between NASA TLX and the blink frequency and duration were -0.17 and 0.446. Reduction of blink frequency and shorter blink duration matched the increasing level of mental workload reported by surgeons. The value of using eye-tracking technology for assessment of surgeon mental workload was shown.

  10. Utilização da função pearson tipo V, Weibull e hiperbólica para modelagem da distribuição de diâmetros

    Directory of Open Access Journals (Sweden)

    Daniel Henrique Breda Binoti

    2013-09-01

    Full Text Available Objetivou-se neste estudo avaliar a eficiência da função log-Pearson tipo V para a descrição da estrutura diamétrica de povoamentos equiâneos de eucaliptos, bem como propor um modelo de distribuição diamétrica utilizando essa função. A modelagem realizada pela função log-Pearson tipo V foi comparada com a modelagem realizada com a função Weibull e hiperbólica. Para isso utilizou-se dados de parcelas permanentes de eucalipto, localizadas na região centro oeste do estado de Minas Gerais. A função Pearson tipo V foi testada em três diferentes configurações, com três e dois parâmetros, e tendo o parâmetro de locação substituído pelo diâmetro mínimo da parcela. A aderência das funções aos dados foi comprovada pela aplicação do teste Kolmogorov-Sminorv (K-S. Todos os ajustes apresentaram aderência aos dados pelo teste KS. As funções Weibull e hiperbólica apresentaram desempenho superior ao demonstrado pela função Pearson tipo V.

  11. The Correlation between Body Mass Index and Routine Parameters in Men Over Fifty

    Directory of Open Access Journals (Sweden)

    Deok Ha Seo

    2017-12-01

    Full Text Available Purpose: This study aimed to investigate the relationships between body mass index (BMI and prostate-specific antigen (PSA levels, international prostate symptom score (IPSS, quality of life (QoL, and prostate volume (PV. Materials and Methods: Height, weight, PSA levels, PV, and IPSS were analyzed in 15,435 patients who underwent a prostate examination between 2001 and 2014. Patients aged <50 years or with a PSA level ≥10 ng/mL were excluded. The relationships between BMI and PSA, IPSS, QoL, and PV were analyzed by a scatter plot, one-way analysis of variance, and the Pearson correlation coefficient. Results: The mean age was 71.95±7.63 years, the mean BMI was 23.59±3.08 kg/m2, the mean PSA level was 1.45±1.45 ng/mL, the mean IPSS was 15.53±8.31, the mean QoL score was 3.48±1.25, and the mean PV was 29.72±14.02 mL. PSA, IPSS, and QoL showed a tendency to decrease with increasing BMI, and there were statistically significant differences for each parameter (p≤0.001. PV showed a significant tendency to increase with BMI (p<0.001. In the correlation analysis, BMI showed a statistically significant correlation (p<0.001 with PSA, IPSS, and QoL, although the correlations were very weak. In contrast, BMI showed a significant correlation with PV (p<0.001, with a meaningful Pearson correlation coefficient of 0.124. Conclusions: Higher BMI was associated with lower PSA levels and higher IPSS and QoL scores. Meanwhile, PV increased with BMI. Although obese individuals had a greater PV, obesity did not aggravate lower urinary tract symptoms.

  12. Dietary Assessment in the MetaCardis Study: Development and Relative Validity of an Online Food Frequency Questionnaire.

    Science.gov (United States)

    Verger, Eric O; Armstrong, Patrice; Nielsen, Trine; Chakaroun, Rima; Aron-Wisnewsky, Judith; Gøbel, Rikke Juul; Schütz, Tatjana; Delaere, Fabien; Gausseres, Nicolas; Clément, Karine; Holmes, Bridget A

    2017-06-01

    The European study MetaCardis aims to investigate the role of the gut microbiota in health and cardiometabolic diseases in France, Germany, and Denmark. To evaluate long-term diet-disease relationships, a food frequency questionnaire (FFQ) was found to be the most relevant dietary assessment method for the MetaCardis study. The objectives of this study were to describe the development of three semiquantitative online FFQs used in the MetaCardis study-one FFQ per country-and to assess the relative validity of the French MetaCardis FFQ. The layout and format of the MetaCardis FFQ was based on the European Prospective Investigation of Cancer (EPIC)-Norfolk FFQ and the content was based on relevant European FFQs. Portion size and nutrient composition were derived from national food consumption surveys and food composition databases. To assess the validity of the French MetaCardis FFQ, a cross-sectional study design was utilized. The validation study included 324 adults recruited between September 2013 and June 2015 from different hospitals in Paris, France. Food intakes were measured with both the French MetaCardis FFQ and 3 consecutive self-administered web-based 24-hour dietary recalls (DRs). Several measures of validity of the French MetaCardis FFQ were evaluated: estimations of food groups, energy, and nutrient intakes from the DRs and the FFQ, Spearman and Pearson correlations, cross-classification, and Bland-Altman analyses. The French MetaCardis FFQ tended to report higher food, energy, and nutrient intakes compared with the DRs. Mean correlation coefficient was 0.429 for food, 0.460 for energy, 0.544 for macronutrients, 0.640 for alcohol, and 0.503 for micronutrient intakes. Almost half of participants (44.4%) were correctly classified within tertiles of consumption, whereas 12.9% were misclassified in the opposite tertile. Performance of the FFQ was relatively similar after stratification by sex. The French MetaCardis FFQ was found to have an acceptable level

  13. Determination of Correlation for Extreme Metocean Variables

    Directory of Open Access Journals (Sweden)

    Nizamani Zafarullah

    2017-01-01

    Full Text Available Metocean environmental load includes wind, wave and currents. Offshore structures are designed for two environmental load design conditions i.e. extreme and operational load conditions of environmental loads are evaluated. The ccorrelation between load variables using Joint probability distribution, Pearson correlation coefficient and Spearman’s rank correlation coefficients methods in Peninsular Malaysia (PM, Sabah and Sarawak are computed. Joint probability distribution method is considered as a reliable method among three different methods to determine the relationship between load variables. The PM has good correlation between the wind-wave and wave-current; Sabah has both strong relationships of wind-wave and wind-current with 50 year return period; Sarawak has good correlation between wind and current in both 50 years and 100 years return period. Since Sabah has good correlation between the associated load variables, no matter in 50 years or 100 years of return period of load combination. Thus, method 1 of ISO 19901-1, specimen provides guideline for metocean loading conditions, can be adopted for design for offshore structure in Sabah. However, due to weak correlations in PM and Sarawak, this method cannot be applied and method 2, which is current practice in offshore industry, should continueto be used.

  14. [Ecological correlation between consumption of alcoholic beverages and liver cirrhosis mortality in Mexico].

    Science.gov (United States)

    Narro-Robles, J; Gutiérrez-Avila, J H

    1997-01-01

    To determine the correlation between alcohol consumption and mortality from liver cirrhosis in Mexico. Analysis of the ecological correlation between the patterns of alcohol consumption determined by the National Addiction Survey in 1993 and mortality by liver cirrhosis, in the period between 1971-1993, in the eight regions in which the country was divided. To determine level of correlation, the Pearson and Spearman coefficients were calculated. Significant correlations were only found with the prevalence of spirits and pulque drinkers; with beer drinkers the correlation was negative. The correlation with pulque is interesting, since pulque consumption is considered to be low scale in some rural areas. The negative correlation with beer may indicate that beer drinking is nor a good indicator of alcoholism. Results, though limited to the possibilities of an ecological study, reveal the necessity of effective actions in the regions where spirits and pulque are consumed in excess.

  15. Correlation between center of pressure and functional balance in non-faller elderly practitioners of Tai Chi Chuan

    OpenAIRE

    Gatica-Rojas, Valeska; Cartes-Vel?squez, Ricardo; Salgado-M?ndez, Rodrigo; Castro-Ram?rez, Rodolfo

    2016-01-01

    [Purpose] This study aimed to determine the correlation between center of pressure and functional balance in non-faller elderly practitioners of Tai Chi. [Subjects and Methods] For the study, nine non-faller elderly practitioners of Tai Chi who were able to maintain a standing posture and walk independently were recruited. Timed one-leg standing and timed up-and-go tests were used as functional balance tests and force platform to measure the center of pressure. The Pearson correlation coeffic...

  16. Validation of the "Quality of Life in Life-Threatening Illness--Family Carer Version" (QOLLTI-F) in German-speaking carers of advanced cancer patients.

    Science.gov (United States)

    Schur, Sophie; Ebert-Vogel, Alexandra; Amering, Michaela; Masel, Eva Katharina; Neubauer, Marie; Schrott, Andrea; Sibitz, Ingrid; Watzke, Herbert; Schrank, Beate

    2014-10-01

    Palliative care is a multidisciplinary approach that focuses on the improvement of quality of life (QOL) of patients as well as their families. QOL research in palliative care has so far primarily focused on patients, but interest in the QOL of their relatives is increasing. For instruments measuring QOL in relatives, data on psychometric properties are often limited, and so far, none has been available in German. This study translates and validates the "Quality of Life in Life-Threatening Illness-Family Carer Version" (QOLLTI-F) in German-speaking carers of advanced cancer patients. The QOLLTI-F was translated from English into German according to the World Health Organisation's recommendations and validated in informal caregivers of terminally ill cancer patients of three Viennese hospitals. Hope was measured to assess concurrent validity; traumatic stress, anxiety, depression and subjective burden were measured to assess discriminant validity. Internal consistency, test-retest reliability and discriminative power were established. The scale's factor structure was explored using a set of factor analyses. Of the 308 caregivers participating in the study, 42 completed the QOLLTI-F retest after a mean of 5 days. The internal consistency was α = 0.85 for the overall scale, Pearson correlation between test and retest lay at r = 0.92. As expected, a significant positive correlation was found with hope (r = 0.40) and significant negative correlations with traumatic stress (r = -0.41), depression (r = -0.51), anxiety (r = -0.52) and overall subjective burden (r = -0.55). The original seven-factor structure was not reproduced, but the scale showed a stable four-factor structure with factors capturing (1) feelings about carers' own life, (2) professional care, (3) interaction with the patient and others and (3) carers' outlook on life. This study provides a sound translation and validation of the first QOL assessment tool for caregivers of

  17. WALKING CAPACITY AND FALLS-EFFICACY CORRELATES WITH PARTICIPATION RESTRICTION IN INDIVIDUALS WITH CHRONIC STROKE: A CROSS SECTIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Neelam Nayak

    2015-02-01

    Full Text Available Background: Mobility impairments seen after Stroke impact walking speed, endurance and balance. Almost all the individuals with Stroke have fear of fall. The physical impairments in balance and gait along with individual’s perception about his/her own abilities to maintain balance might have an impact on level of activity and participation in the community. The association of these variables with recovery of Stroke has been well studied. However, it is currently unknown which of these variables are most associated with activity and participation in the community. This study aimed to identify the correlation of walking capacity and perception of fall with activity & participation. Methods: 30 Subjects were assessed for - walking capacity (6 minute walk test & Self-efficacy for falls (Modified Falls Efficacy scale. Level of Activity Limitation (AL & Participation Restriction (PR was graded on validated ICF Measure of Participation and Activities. (IMPACT-S Results: Data was analyzed using Pearson's correlation coefficient & regression model. Walking distance and Falls-efficacy is significantly correlated (r=-0.751 and -0.683, respectively with Participation restriction. Walking distance correlated with Activity Limitation (r=-0.714 significantly. Falls efficacy has a correlation coefficient of -0.642 with Activity Limitation. When put into Regression models, Walking Capacity & Gait Velocity was found to be independently associated with AL &PR. Conclusion: There is significant relationship between falls self-efficacy, walking capacity and Post-stroke activity & participation. Participation can be impacted by factors such as self-motivation and confidence about one's balance abilities. This is reflected by the correlation between falls efficacy and participation. Physical parameters such as the distance walked can contribute to participating in the community, and can predict variation in AL-PR

  18. Validation of the one pass measure for motivational interviewing competence.

    Science.gov (United States)

    McMaster, Fiona; Resnicow, Ken

    2015-04-01

    This paper examines the psychometric properties of the OnePass coding system: a new, user-friendly tool for evaluating practitioner competence in motivational interviewing (MI). We provide data on reliability and validity with the current gold-standard: Motivational Interviewing Treatment Integrity tool (MITI). We compared scores from 27 videotaped MI sessions performed by student counselors trained in MI and simulated patients using both OnePass and MITI, with three different raters for each tool. Reliability was estimated using intra-class coefficients (ICCs), and validity was assessed using Pearson's r. OnePass had high levels of inter-rater reliability with 19/23 items found from substantial to almost perfect agreement. Taking the pair of scores with the highest inter-rater reliability on the MITI, the concurrent validity between the two measures ranged from moderate to high. Validity was highest for evocation, autonomy, direction and empathy. OnePass appears to have good inter-rater reliability while capturing similar dimensions of MI as the MITI. Despite the moderate concurrent validity with the MITI, the OnePass shows promise in evaluating both traditional and novel interpretations of MI. OnePass may be a useful tool for developing and improving practitioner competence in MI where access to MITI coders is limited. Copyright © 2015. Published by Elsevier Ireland Ltd.

  19. Reliability and validity of a questionnaire to measure personal, social and environmental correlates of fruit and vegetable intake in 10-11-year-old children in five European countries

    DEFF Research Database (Denmark)

    De Bourdeaudhuij, I; Klepp, K-I; Due, P

    2005-01-01

    To investigate the internal consistency of the scales and the test-retest reliability and predictive validity of behaviour theory-based constructs measuring personal, social and environmental correlates of fruit and vegetable intake in 10-11-year-old children.......To investigate the internal consistency of the scales and the test-retest reliability and predictive validity of behaviour theory-based constructs measuring personal, social and environmental correlates of fruit and vegetable intake in 10-11-year-old children....

  20. Estimation of Correlation between Chronological Age, Skeletal Age and Dental Age in Children- A Cross-sectional Study.

    Science.gov (United States)

    Macha, Madhulika; Lamba, Bharti; Avula, Jogendra Sai Sankar; Muthineni, Sridhar; Margana, Pratap Gowd Jai Shankar; Chitoori, Prasad

    2017-09-01

    In the modern era, identification and determination of age is imperative for diversity of reasons that include disputed birth records, premature delivery, legal issues and for validation of birth certificate for school admissions, adoption, marriage, job and immigration. Several growth assessment parameters like bone age, dental age and the combination of both have been applied for different population with variable outcomes. It has been well documented that the chronological age does not necessarily correlate with the maturational status of a child. Hence, efforts were made to determine a child's developmental age by using dental age (calcification of teeth) and skeletal age (skeletal maturation). The present study was aimed to correlate the chronological age, dental age and skeletal age in children from Southeastern region of Andhra Pradesh, India. Out of the total 900 screened children, only 100 subjects between age groups of 6-14 years with a mean age of 11.3±2.63 for males and 10.77±2.24 for females were selected for the study. Dental age was calculated by Demirjian method and skeletal age by modified Middle Phalanx of left hand third finger (MP3) method. Pearson's and Spearman's correlation tests were done to estimate the correlation between chronological, dental and skeletal ages among study population. There was a significant positive correlation between chronological age, dental age and all stages of MP3 among males. Similar results were observed in females, except for a non-significant moderate correlation between chronological age and dental age in the H stage of the MP3 region. The results of the present study revealed correlation with statistical significance (p<0.05) between chronological, dental and skeletal ages among all the subjects (48 males and 52 females) and females attained maturity earlier than males in the present study population.

  1. 18F-FDG imaging of human atherosclerotic carotid plaques reflects gene expression of the key hypoxia marker HIF-1α

    DEFF Research Database (Denmark)

    Pedersen, Sune Folke; Græbe, Martin; Hag, Anne Mette F

    2013-01-01

    /computed tomography (CT) scans performed the day before CEA. Immunohistochemistry was used to validate target-gene protein expression. In univariate linear regression analysis HIF-1α was significantly correlated with (18)F-FDG-uptake (SUVmax) as was CD68. A two-tailed Pearson regression model demonstrated that HIF-1α...

  2. Validation of the FACT-B+4-UL questionnaire and exploration of its predictive value in women submitted to surgery for breast cancer.

    Science.gov (United States)

    Andrade Ortega, Juan Alfonso; Millán Gómez, Ana Pilar; Ribeiro González, Marisa; Martínez Piró, Pilar; Jiménez Anula, Juan; Sánchez Andújar, María Belén

    2017-06-21

    The early detection of upper limb complications is important in women operated on for breast cancer. The "FACT-B+4-UL" questionnaire, a specific variant of the Functional Assessment of Cancer Therapy-Breast (FACT-B) is available among others to measure the upper limb function. The Spanish version of the upper limb subscale of the FACT-B+4 was validated in a prospective cohort of 201 women operated on for breast cancer (factor analysis, internal consistency, test-retest reliability, construct validity and sensitivity to change were determined). Its predictive capacity of subsequent lymphoedema and other complications in the upper limb was explored using logistic regression. This subscale is unifactorial and has a great internal consistency (Cronbach's alpha: 0.87), its test-retest reliability and construct validity are strong (intraclass correlation coefficient: 0.986; Pearson's R with "Quick DASH": 0.81) as is its sensitivity to change. It didn't predict the onset of lymphedema. Its predictive capacity for other upper limb complications is low. FACT-B+4-UL is useful in measuring upper limb disability in women surgically treated for breast cancer; but it does not predict the onset of lymphoedema and its predictive capacity for others complications in the upper limb is low. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  3. Validity of self-reported lunch recalls in Swedish school children aged 6-8 years.

    Science.gov (United States)

    Hunsberger, Monica; Pena, Pablo; Lissner, Lauren; Grafström, Lisen; Vanaelst, Barbara; Börnhorst, Claudia; Pala, Valeria; Eiben, Gabriele

    2013-09-18

    Previous studies have suggested that young children are inaccurate reporters of dietary intake. The purpose of this study was to validate a single recall of the previous day's school lunch reported by 6-8 year old Swedish children and to assess teacher-recorded intake of the same meal in a standardized food journal. An additional research question was whether parents could report their child's intake of the previous day's lunch. Subjects constituted a convenience sample from the large, multi-country study Identification and prevention of Dietary- and lifestyle-induced health EFfects In Children and infantS (IDEFICS). Validations of both children's recalls and teachers' records were made by comparing results with the duplicate plate reference method. Twenty-five children (12 boys/13 girls) aged 6-8 years participated in the validation study at one school in western Sweden. Children were accurate self-reporters of their dietary intake at lunch, with no significant difference between reported and weighed intake (Mean difference (SD): 7(50) kcals, p=0.49). Teachers significantly over-reported intake (Mean difference (SD): 65(79) kcals, p=0.01). For both methods, child-reported and teacher-recorded, correlations with weighed intake were strong (Pearson's correlations r=0.92, pteacher-records and weighed intakes. Foods were recalled by children with a food-match rate of 90%. In all cases parents themselves were unable to report on quantities consumed and only four of 25 children had parents with knowledge regarding food items consumed. Children 6-8 years of age accurately recalled their school lunch intake for one occasion while teachers recorded with less accuracy. Our findings suggest that children as young as six years of age may be better able to report on their dietary intake than previously suggested, at least for one main meal at school. Teacher-recorded intake provides a satisfactory estimate but with greater systematic deviation from the weighed intake

  4. C-reactive protein level in coronary artery disease and its correlation with serum d-dimer

    International Nuclear Information System (INIS)

    Gul, C.; Marwat, Z.I.; Israr, M.; Hanif, R.; Arshad, M.

    2017-01-01

    C-reactive protein concentration has continuous associations with risk of coronary artery disease, ischemic stroke and death from several cancers. In addition, several studies have shown that CRP could be used to predict first ever myocardial infarction and stroke in healthy subjects, as well as outcome in acute setting. High levels of another biomarker, D-dimer, have been found to be independently associated with occurrence of coronary events. Methods: This correlational study was carried out at the Department of Cardiology, Ayub Teaching Hospital Abbottabad, in collaboration with the department of Biochemistry Postgraduate Medical Institute Lahore from 15th July 2013 to 15th May 2014. Patients aged 30 years or more of either gender having coronary artery disease was included in the study. Their serum D-dimer levels and C-reactive protein levels were measured for correlation with coronary artery disease. Results: A total of 50 patients of CAD were included in this study. Out of these 30 (60 percent) were males and 20 (40 percent) were females. Elevated CRP levels and D-dimer levels were noted in all of these patients. Pearson correlation coefficient test was performed on both CRP and D-dimer levels. Pearson correlation coefficient was calculated to be r= -0.1522 and when a p value was calculated, it was found to be 0.292 which implied that the results were not significant. Conclusion: This study showed that there is no correlation between CRP levels and D-dimer levels in patients with Coronary Artery Disease. (author)

  5. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0....... Correlations between mean ADC and EI and 15th percentile were both r=0.90 and for MLD r=0.59. There was higher correlation between mean ADC and %predicted DLCO (r=0.90) than between EI and %predicted DLCO (r=0.76). CONCLUSION: HP (3)He-MRI correlates well with density measurements from MSCT and agrees better...

  6. Collective Correlations of Brodmann Areas fMRI Study with RMT-Denoising

    OpenAIRE

    Burda, Zdzislaw; Kornelsen, Jennifer; Nowak, Maciej A.; Porebski, Bartosz; Sboto-Frankenstein, Uta; Tomanek, Boguslaw; Tyburczyk, Jacek

    2013-01-01

    We study collective behavior of Brodmann regions of human cerebral cortex using functional Magnetic Resonance Imaging (fMRI) and Random Matrix Theory (RMT). The raw fMRI data is mapped onto the cortex regions corresponding to the Brodmann areas with the aid of the Talairach coordinates. Principal Component Analysis (PCA) of the Pearson correlation matrix for 41 different Brodmann regions is carried out to determine their collective activity in the idle state and in the active state stimulated...

  7. An automatic measure of progression during colonoscopy correlates to patient experienced pain

    DEFF Research Database (Denmark)

    Preisler, Louise; Bulut, Mustafa; Svendsen, Morten Soendergaard

    2018-01-01

    recordings were used for evaluation. We demonstrated a moderate correlation between CoPS and patient experienced pain, Pearson's r = -0.47 (p ... progression. CoPS deliver a numeric score and a graphic map. A high score expresses a rapid and smooth progression. Aims of study were to explore the correlation between CoPS and patient experienced pain and to identity locations associated with pain. METHODS AND MATERIALS: Patients listed for colonoscopy.......61 Passage of the sigmoid colon, right and left flexures were associated with pain for 51%, 33% and 25% of the patients, respectively. CONCLUSION: A moderate correlation between CoPS and patient experienced pain suggest that CoPS measure inserting skills but might also be a measure of a gentle performance...

  8. Isometric hand grip strength measured by the Nintendo Wii Balance Board - a reliable new method.

    Science.gov (United States)

    Blomkvist, A W; Andersen, S; de Bruin, E D; Jorgensen, M G

    2016-02-03

    Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson's product-moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.

  9. A powerful nonparametric method for detecting differentially co-expressed genes: distance correlation screening and edge-count test.

    Science.gov (United States)

    Zhang, Qingyang

    2018-05-16

    Differential co-expression analysis, as a complement of differential expression analysis, offers significant insights into the changes in molecular mechanism of different phenotypes. A prevailing approach to detecting differentially co-expressed genes is to compare Pearson's correlation coefficients in two phenotypes. However, due to the limitations of Pearson's correlation measure, this approach lacks the power to detect nonlinear changes in gene co-expression which is common in gene regulatory networks. In this work, a new nonparametric procedure is proposed to search differentially co-expressed gene pairs in different phenotypes from large-scale data. Our computational pipeline consisted of two main steps, a screening step and a testing step. The screening step is to reduce the search space by filtering out all the independent gene pairs using distance correlation measure. In the testing step, we compare the gene co-expression patterns in different phenotypes by a recently developed edge-count test. Both steps are distribution-free and targeting nonlinear relations. We illustrate the promise of the new approach by analyzing the Cancer Genome Atlas data and the METABRIC data for breast cancer subtypes. Compared with some existing methods, the new method is more powerful in detecting nonlinear type of differential co-expressions. The distance correlation screening can greatly improve computational efficiency, facilitating its application to large data sets.

  10. Validity of the MarkWiiR for kinematic analysis during walking and running gaits

    Directory of Open Access Journals (Sweden)

    Johnny Padulo

    2014-11-01

    Full Text Available The aim of this study was to validate the MarkWiiR (MW captured by the Nintendo Wii-Remote (100-Hz to assess active marker displacement by comparison with 2D video analysis. Ten participants were tested on a treadmill at different walking (1<6 km · h-1 and running (10<13 km · h-1 speeds. During the test, the active marker for MW and a passive marker for video analysis were recorded simultaneously with the two devices. The displacement of the marker on the two axes (x-y was computed using two different programs, Kinovea 0.8.15 and CoreMeter, for the camera and MW, respectively. Pearson correlation was acceptable (x-axis r≥0.734 and y-axis r≥0.684, and Bland–Altman plots of the walking speeds showed an average error of 0.24±0.52% and 1.5±0.91% for the x- and y-axis, respectively. The difference of running speeds showed average errors of 0.67±0.33% and 1.26±0.33% for the x- and y-axes, respectively. These results demonstrate that the two measures are similar from both the x- and the y-axis perspective. In conclusion, these findings suggest that the MarkWiiR is a valid and reliable tool to assess the kinematics of an active marker during walking and running gaits.

  11. Closure and ratio correlation analysis of lunar chemical and grain size data

    Science.gov (United States)

    Butler, J. C.

    1976-01-01

    Major element and major element plus trace element analyses were selected from the lunar data base for Apollo 11, 12 and 15 basalt and regolith samples. Summary statistics for each of the six data sets were compiled, and the effects of closure on the Pearson product moment correlation coefficient were investigated using the Chayes and Kruskal approximation procedure. In general, there are two types of closure effects evident in these data sets: negative correlations of intermediate size which are solely the result of closure, and correlations of small absolute value which depart significantly from their expected closure correlations which are of intermediate size. It is shown that a positive closure correlation will arise only when the product of the coefficients of variation is very small (less than 0.01 for most data sets) and, in general, trace elements in the lunar data sets exhibit relatively large coefficients of variation.

  12. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol.

    Science.gov (United States)

    Pérula, Luis Á; Campiñez, Manuel; Bosch, Josep M; Barragán Brun, Nieves; Arboniés, Juan C; Bóveda Fontán, Julia; Martín Alvarez, Remedios; Prados, Jose A; Martín-Rioboó, Enrique; Massons, Josep; Criado, Margarita; Fernández, José Á; Parras, Juan M; Ruiz-Moral, Roger; Novo, Jesús M

    2012-11-22

    Lifestyle is one of the main determinants of people's health. It is essential to find the most effective prevention strategies to be used to encourage behavioral changes in their patients. Many theories are available that explain change or adherence to specific health behaviors in subjects. In this sense the named Motivational Interviewing has increasingly gained relevance. Few well-validated instruments are available for measuring doctors' communication skills, and more specifically the Motivational Interviewing. The hypothesis of this study is that the Scale for Measuring Motivational Interviewing Skills (EVEM questionnaire) is a valid and reliable instrument for measuring the primary care professionals skills to get behavior change in patients. To test the hypothesis we have designed a prospective, observational, multi-center study to validate a measuring instrument. - Thirty-two primary care centers in Spain. -Sampling and Size: a) face and consensual validity: A group composed of 15 experts in Motivational Interviewing. b) Assessment of the psychometric properties of the scale; 50 physician- patient encounters will be videoed; a total of 162 interviews will be conducted with six standardized patients, and another 200 interviews will be conducted with 50 real patients (n=362). Four physicians will be specially trained to assess 30 interviews randomly selected to test the scale reproducibility. -Measurements for to test the hypothesis: a) Face validity: development of a draft questionnaire based on a theoretical model, by using Delphi-type methodology with experts. b) Scale psychometric properties: intraobservers will evaluate video recorded interviews: content-scalability validity (Exploratory Factor Analysis), internal consistency (Cronbach alpha), intra-/inter-observer reliability (Kappa index, intraclass correlation coefficient, Bland & Altman methodology), generalizability, construct validity and sensitivity to change (Pearson product-moment correlation

  13. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol

    Directory of Open Access Journals (Sweden)

    Pérula Luis Á

    2012-11-01

    sensitivity to change (Pearson product–moment correlation coefficient. Discussion The verification of the hypothesis that EVEM is a valid and reliable tool for assessing motivational interviewing would be a major breakthrough in the current theoretical and practical knowledge, as it could be used to assess if the providers put into practice a patient centered communication style and can be used both for training or researching purposes. Trials registration Dislip-EM study NCT01282190 (ClinicalTrials.gov

  14. Correlation and agreement: overview and clarification of competing concepts and measures.

    Science.gov (United States)

    Liu, Jinyuan; Tang, Wan; Chen, Guanqin; Lu, Yin; Feng, Changyong; Tu, Xin M

    2016-04-25

    Agreement and correlation are widely-used concepts that assess the association between variables. Although similar and related, they represent completely different notions of association. Assessing agreement between variables assumes that the variables measure the same construct, while correlation of variables can be assessed for variables that measure completely different constructs. This conceptual difference requires the use of different statistical methods, and when assessing agreement or correlation, the statistical method may vary depending on the distribution of the data and the interest of the investigator. For example, the Pearson correlation, a popular measure of correlation between continuous variables, is only informative when applied to variables that have linear relationships; it may be non-informative or even misleading when applied to variables that are not linearly related. Likewise, the intraclass correlation, a popular measure of agreement between continuous variables, may not provide sufficient information for investigators if the nature of poor agreement is of interest. This report reviews the concepts of agreement and correlation and discusses differences in the application of several commonly used measures.

  15. Serum adipokines (adiponectin and resistin) correlation in developing gestational diabetes mellitus: pilot study.

    Science.gov (United States)

    Siddiqui, Khalid; George, Teena P; Nawaz, Shaik Sarfaraz; Shehata, Nevene; El-Sayed, Amel Ahmed; Khanam, Latifa

    2018-06-01

    Adiponectin and resistin are adipose tissue-derived proteins with antagonistic actions; adiponectin has insulin sensitive properties while resistin is involved in the development of insulin resistance. We analyzed adiponectin and resistin levels in gestational diabetes mellitus (GDM) women to evaluate the association of these adipokines in a very high diabetes prevalence population. An age-matched case-control study of GDM and normal pregnant women in Saudi population. We recruited 90 pregnant women at 24-32 weeks of gestation. Glucose levels (fasting, 1, 2, and 3 h) and lipid parameters (cholesterol, triglyceride, HDL cholesterol, LDL cholesterol) were measured. Serum adiponectin and resistin levels were analyzed using Randox evidence biochip analyzer. Pearson's correlation coefficient was used to determine the association of adiponectin and resistin with GDM risk factors. GDM women showed significantly low adiponectin and high resistin levels when compared with control group. Pearson's correlation analysis of adiponectin and resistin in all the subjects with various GDM risk factors showed a negative association of adiponectin (r = -0.32, p = .05) and a positive correlation of resistin (r = 0.41, p = .01) with LDL cholesterol. This study analyzes adiponectin and resistin levels together, as accumulating evidences shows that these are involved in the pathophysiology of GDM. This is going to help to determine in conjunction with traditional risk factors the incremental value of circulating adiponectin and resistin in developing GDM.

  16. Comparative validity of the ASSO–Food Frequency Questionnaire for the web-based assessment of food and nutrients intake in adolescents

    Directory of Open Access Journals (Sweden)

    Garden Tabacchi

    2015-04-01

    Full Text Available Background: A new web-based food frequency questionnaire (the ASSO–FFQ was developed within the ASSO Project funded by the Italian Ministry of Health. Objective: The aim of the present study is to assess the validity of the ASSO–FFQ at food groups, energy, and nutrients level. Design and subjects: The validation study compared the ASSO–FFQ against a weighted food record (WFR measuring foods, beverages and supplements intake, compiled during the week following the ASSO–FFQ administration. Ninety-two subjects aged 14–17, recruited from secondary schools in Palermo (Italy, completed the ASSO–FFQ and WFR. The intake of 24 food groups, energy, and 52 nutrients were taken as main outcomes. Tests for paired observations, Spearman and Pearson's correlation coefficients (cc, kappa statistics and classification in quintiles, Bland–Altman plots and multiple regressions, on untransformed and transformed data were used for the statistical analysis. Results: High cc (≥0.40 were found for soft drinks, milk, tea/coffee, vegetables, and lactose; fair energy-adjusted cc (0.25–0.40 for water, alcoholic drinks, breakfast cereals, fishery products, savory food, fruit juice, eggs, and 19 nutrients. The subjects classified in the same or adjacent quintile for food groups ranged from 40% (alcoholic drinks to 100% (dried fruit; for energy and nutrients from 43% (phosphorus, thiamin, niacin to 77% (lactose. Mean differences were not significant for water, soft drinks, meat, sweets, animal fats, milk and white bread, and vitamin B12 and folate. Limits of Agreement were broad for all food groups and nutrients. School, gender, alcohol consumption and between meals mainly affected most food groups’ intake differences. Gender stratification showed females had increased Pearson's cc for energy and 28 nutrients, such as almost all fats, carbohydrates, vitamins and minerals. Conclusions: The ASSO–FFQ could be applied in epidemiological studies for the

  17. Bladder transitional cell carcinoma: correlation of contrast enhancement on computed tomography with histological grade and tumour angiogenesis

    International Nuclear Information System (INIS)

    Xie, Q.; Zhang, J.; Wu, P.-H.; Jiang, X.-Q.; Chen, S.-L.; Wang, Q.-L.; Xu, J.; Chen, G.-D.; Deng, J.-H.

    2005-01-01

    AIM: To investigate the correlation between the degree of contrast enhancement of bladder cancer in the early enhanced phase of helical computed tomography (CT) and microvessel density (MVD), vascular endothelial growth factor (VEGF) and histological grade. MATERIALS AND METHODS: Sixty-five patients with transitional cell carcinoma of the bladder were examined by incremental unenhanced CT and helical CT at 40-45 s after initiation of intravenous administration of contrast medium before surgery. The CT density in Hounsfield units of bladder carcinomas were measured in the middle of the maximum diameter section of the cancer lesions on unenhanced and enhanced CT. The degree of contrast enhancement of the tumour was determined as the absolute increase in Hounsfield units. Histological grade, VEGF and MVD were analysed for each cancer. The Pearson and Spearman correlation tests were used to determine the strength of the relationships between CT enhancement and histological grade, VEGF expression and MVD. RESULTS: Different degrees of enhancement were observed in 91 cancers during the early enhanced phase of helical CT. Mean MVDs and mean CT enhancing values of different histological grade groups were statistically different (p<0.001). A positive correlation was found in the CT-enhancing value of bladder cancer and MVD (Pearson correlation test; r=0.938, p<0.001) and histological grade (Spearman rank correlation; r=0.734, p<0.001). VEGF of bladder cancer did not correlate with the change in CT attenuation (Spearman rank correlation; r=0.087, p=0.410) and MVD (Spearman rank correlation, r=0.103, p=0.330). CONCLUSION: In bladder cancer, the degree of contrast enhancement during the early enhanced helical CT is correlated with the MVD and histological grade of tumour. It is possible that MVD is the histopathological basis of early contrast enhancement of bladder cancer

  18. Assessing physiotherapists' communication skills for promoting patient autonomy for self-management: reliability and validity of the communication evaluation in rehabilitation tool.

    Science.gov (United States)

    Murray, Aileen; Hall, Amanda; Williams, Geoffrey C; McDonough, Suzanne M; Ntoumanis, Nikos; Taylor, Ian; Jackson, Ben; Copsey, Bethan; Hurley, Deirdre A; Matthews, James

    2018-02-27

    To assess the inter-rater reliability and concurrent validity of the Communication Evaluation in Rehabilitation Tool, which aims to externally assess physiotherapists competency in using Self-Determination Theory-based communication strategies in practice. Audio recordings of initial consultations between 24 physiotherapists and 24 patients with chronic low back pain in four hospitals in Ireland were obtained as part of a larger randomised controlled trial. Three raters, all of whom had Ph.Ds in psychology and expertise in motivation and physical activity, independently listened to the 24 audio recordings and completed the 18-item Communication Evaluation in Rehabilitation Tool. Inter-rater reliability between all three raters was assessed using intraclass correlation coefficients. Concurrent validity was assessed using Pearson's r correlations with a reference standard, the Health Care Climate Questionnaire. The total score for the Communication Evaluation in Rehabilitation Tool is an average of all 18 items. Total scores demonstrated good inter-rater reliability (Intraclass Correlation Coefficient (ICC) = 0.8) and concurrent validity with the Health Care Climate Questionnaire total score (range: r = 0.7-0.88). Item-level scores of the Communication Evaluation in Rehabilitation Tool identified five items that need improvement. Results provide preliminary evidence to support future use and testing of the Communication Evaluation in Rehabilitation Tool. Implications for Rehabilitation Promoting patient autonomy is a learned skill and while interventions exist to train clinicians in these skills there are no tools to assess how well clinicians use these skills when interacting with a patient. The lack of robust assessment has severe implications regarding both the fidelity of clinician training packages and resulting outcomes for promoting patient autonomy. This study has developed a novel measurement tool Communication Evaluation in Rehabilitation Tool and a

  19. Concurrent validity, discriminatory power and feasibility of the instrument for Identification of Parents At Risk for child Abuse and Neglect (IPARAN).

    Science.gov (United States)

    Horrevorts, Esther M B; van Grieken, Amy; Mieloo, Cathelijne L; Hafkamp-de Groen, Esther; Bannink, Rienke; Bouwmeester-Landweer, Merian B R; Broeren, Suzanne; Raat, Hein

    2017-08-23

    To determine the feasibility, concurrent validity and discriminatory power of the instrument for Identification of Parents At Risk for child Abuse and Neglect (IPARAN) among Dutch parents with a newborn child. Community paediatrics. Data from a controlled trial were used. In total, 2659 Dutch parents with a newborn child were invited to participate. Of the 2659 parents, 759 parents filled in the consent form and participated in the study. Concurrent validity was determined by calculating correlations-using the Pearson's correlation (r)-between the IPARAN score and related constructs from the following instruments: the Empowerment Questionnaire 2.0, the Family Functioning Questionnaire and the Parenting Stress Questionnaire. Discriminatory power was determined by calculating receiver operating characteristic (ROC) curves between high-risk mothers and low-risk mothers according to their scores on the related constructs. Feasibility was determined by examining the percentage of missing answers. In terms of concurrent validity, we found that 3 out of 12 correlations between the IPARAN score and related constructs were strong (ie, r>0.50) and 4 out of 12 were medium (ie, r=0.30-0.49). In terms of discriminatory power, mothers with a score in the borderline/clinical range or lowest 10 percent (P10) range of the related constructs (high-risk mothers) had a higher IPARAN score than mothers with a score in the normal range or highest 90 percent (P90) range of the related constructs (low-risk mothers). Effect sizes varied from d=0.37 to d=1.93, and the area under the ROC curve varied from 0.62 to 0.93. Regarding feasibility, the part of the IPARAN filled in by the mother had on average 0.7% missing answers, whereas the part of the IPARAN filled in by the father had on average 1.7% missing answers. The results of this study support the concurrent validity, discriminatory power and feasibility of the IPARAN among a population of Dutch parents with a newborn child.

  20. The Modified Low Back Pain Disability Questionnaire: Reliability, Validity, and Responsiveness of a Dutch Language Version.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Deckers, Kristiaan; Stassijns, Gaetane

    2018-03-01

    Cross-sectional study. The goal of this study is to translate the English version of the Modified Low Back Pain Disability Questionnaire (MDQ) into a Dutch version and investigate its clinimetric properties for patients with nonspecific chronic low back pain (CLBP). Fritz et al (2001) developed a modified version of the Oswestry Disability Questionnaire (ODI) to assess functional status and named it the MDQ. In this version, a question regarding employment and homemaking ability was substituted for the question related to sex life. Good clinimetric properties for the MDQ were identified but up until now it is not clear whether the clinimetric properties of the MDQ would change if it was translated into a Dutch version. Translation of the MDQ into Dutch was done in 4 steps. Test-retest reliability was investigated using the intraclass correlation coefficient (ICC) model. Validity was calculated using Pearson correlations and a 2-way analysis of variance for repeated measures. Finally, responsiveness was calculated with the area under the curve (AUC), minimal detectable change (MDC), and the standardized response mean (SRM). A total of 80 completed questionnaires were collected in 3 different hospitals and a total of 43 patients finished a 9 weeks intervention period, completing the retest. Test-retest reliability was excellent with an ICC of 0.89 (95% confidence interval [CI], 0.74-0.95). To confirm the convergent validity, the MDQ answered all predefined hypothesises (r = -0.65-0.69/P = 0.01-0.00) and good results for construct validity were found (P = 0.02). The MDQ had an AUC of 0.64 (95% confidence interval [CI], 0.47-0.81), an MDC of 8.80 points, and a SRM of 0.65. The Dutch version of the MDQ shows good clinimetric properties and is shown to be usable in the assessment of the functional status of Dutch-speaking patients with nonspecific CLBP. 3.