WorldWideScience

Sample records for validation testing system

  1. Test rig overview for validation and reliability testing of shutdown system software

    International Nuclear Information System (INIS)

    Zhao, M.; McDonald, A.; Dick, P.

    2007-01-01

    The test rig for Validation and Reliability Testing of shutdown system software has been upgraded from the AECL Windows-based test rig previously used for CANDU6 stations. It includes a Virtual Trip Computer, which is a software simulation of the functional specification of the trip computer, and a real-time trip computer simulator in a separate chassis, which is used during the preparation of trip computer test cases before the actual trip computers are available. This allows preparation work for Validation and Reliability Testing to be performed in advance of delivery of actual trip computers to maintain a project schedule. (author)

  2. A Human Proximity Operations System test case validation approach

    Science.gov (United States)

    Huber, Justin; Straub, Jeremy

    A Human Proximity Operations System (HPOS) poses numerous risks in a real world environment. These risks range from mundane tasks such as avoiding walls and fixed obstacles to the critical need to keep people and processes safe in the context of the HPOS's situation-specific decision making. Validating the performance of an HPOS, which must operate in a real-world environment, is an ill posed problem due to the complexity that is introduced by erratic (non-computer) actors. In order to prove the HPOS's usefulness, test cases must be generated to simulate possible actions of these actors, so the HPOS can be shown to be able perform safely in environments where it will be operated. The HPOS must demonstrate its ability to be as safe as a human, across a wide range of foreseeable circumstances. This paper evaluates the use of test cases to validate HPOS performance and utility. It considers an HPOS's safe performance in the context of a common human activity, moving through a crowded corridor, and extrapolates (based on this) to the suitability of using test cases for AI validation in other areas of prospective application.

  3. Some Findings from Thermal-Hydraulic Validation Tests for SMART Passive Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Sik; Bae, Hwang; Ryu, Sung-Uk; Ryu, Hyobong; Shin, Yong-Cheol; Min, Kyoung-Ho; Yi, Sung-Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    To satisfy the domestic and international needs for nuclear safety improvement after the Fukushima accident, an effort to improve its safety has been studied, and a Passive Safety System (PSS) for SMART has been designed. In addition, an Integral Test Loop for the SMART design (SMART-ITL, or FESTA) has been constructed and it finished its commissioning tests in 2012. Consequently, a set of Design Base Accident (DBA) scenarios have been simulated using SMARTITL. Recently, a test program to validate the performance of the SMART PSS was launched and its scaled-down test facility was additionally installed at the existing SMART-ITL facility. In this paper, some findings from the validation tests for the SMART PSS will be summarized. The acquired data will be used to validate the safety analysis code and its related models, to evaluate the performance of SMART PSS, and to provide base data during the application phase of SDA revision and construction licensing. A test program to validate the performance of SMARS PSS was launched with an additional scaleddown test facility of SMART PSS, which will be installed at the existing SMART-ITL facility. In this paper, some findings from the validation tests of the SMART passive safety system during 2013-2014 were summarized. They include a couple of SMART PSS tests using active pumps and several 1-train SMART PSS tests. From the test results it was estimated that the SMART PSS has sufficient cooling capability to deal with the SBLOCA scenario of SMART. During the SBLOCA scenario, in the CMT the water layer inventory was well stratified thermally and the safety injection water was injected efficiently into the RPV from the initial period and cools down the RCS properly.

  4. Converting Hangar High Expansion Foam Systems to Prevent Cockpit Damage: Full-Scale Validation Tests

    Science.gov (United States)

    2017-09-01

    AFCEC-CO-TY-TR-2018-0001 CONVERTING HANGAR HIGH EXPANSION FOAM SYSTEMS TO PREVENT COCKPIT DAMAGE: FULL-SCALE VALIDATION TESTS Gerard G...manufacturer, or otherwise does not constitute or imply its endorsement, recommendation , or approval by the United States Air Force. The views and...09-2017 Final Test Report May 2017 Converting Hangar High Expansion Foam Systems to Prevent Cockpit Damage: Full-Scale Validation Tests N00173-15-D

  5. Convergent validity test, construct validity test and external validity test of the David Liberman algorithm

    Directory of Open Access Journals (Sweden)

    David Maldavsky

    2013-08-01

    Full Text Available The author first exposes a complement of a previous test about convergent validity, then a construct validity test and finally an external validity test of the David Liberman algorithm.  The first part of the paper focused on a complementary aspect, the differential sensitivity of the DLA 1 in an external comparison (to other methods, and 2 in an internal comparison (between two ways of using the same method, the DLA.  The construct validity test exposes the concepts underlined to DLA, their operationalization and some corrections emerging from several empirical studies we carried out.  The external validity test examines the possibility of using the investigation of a single case and its relation with the investigation of a more extended sample.

  6. A software prototype development of human system interfaces for human factors engineering validation tests of SMART MCR

    International Nuclear Information System (INIS)

    Lim, Jong Tae; Han, Kwan Ho; Yang, Seung Won

    2011-02-01

    An integrated system validation test bed used for human factors engineering validation test is being developed. This study has a goal to develop a software prototype for HFE validation of SMART MCR design. To achieve these, first, some prototype specifications of the software was developed. Then software prototypes of alarm reduction logic system, Plant Protection System, ESF-CCS, Elastic Tile Alarm Indication, and EID-based HSIs were implemented as codes. Test procedures for the software prototypes were established to verify the completeness of the codes implemented. The careful software test has been done according to these test procedures, and the result were documented

  7. Experimental Testing Procedures and Dynamic Model Validation for Vanadium Redox Flow Battery Storage System

    DEFF Research Database (Denmark)

    Baccino, Francesco; Marinelli, Mattia; Nørgård, Per Bromand

    2013-01-01

    The paper aims at characterizing the electrochemical and thermal parameters of a 15 kW/320 kWh vanadium redox flow battery (VRB) installed in the SYSLAB test facility of the DTU Risø Campus and experimentally validating the proposed dynamic model realized in Matlab-Simulink. The adopted testing...... efficiency of the battery system. The test procedure has general validity and could also be used for other storage technologies. The storage model proposed and described is suitable for electrical studies and can represent a general model in terms of validity. Finally, the model simulation outputs...

  8. Validation of artificial skin equivalents as in vitro testing systems

    Science.gov (United States)

    Schmitt, Robert; Marx, Ulrich; Walles, Heike; Schober, Lena

    2011-03-01

    With the increasing complexity of the chemical composition of pharmaceuticals, cosmetics and everyday substances, the awareness of potential health issues and long term damages for humanoid organs is shifting into focus. Artificial in vitro testing systems play an important role in providing reliable test conditions and replacing precarious animal testing. Especially artificial skin equivalents ASEs are used for a broad spectrum of studies like penetration, irritation and corrosion of substances. One major challenge in tissue engineering is the qualification of each individual ASE as in vitro testing system. Due to biological fluctuations, the stratum corneum hornified layer of some ASEs may not fully develop or other defects might occur. For monitoring these effects we developed an fully automated Optical Coherence Tomography device. Here, we present different methods to characterize and evaluate the quality of the ASEs based on image and data processing of OCT B-scans. By analysing the surface structure, defects, like cuts or tears, are detectable. A further indicator for the quality of the ASE is the morphology of the tissue. This allows to determine if the skin model has reached the final growth state. We found, that OCT is a well suited technology for automatically characterizing artificial skin equivalents and validating the application as testing system.

  9. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  10. Validating safeguards effectiveness given inherently limited test data

    International Nuclear Information System (INIS)

    Sicherman, A.

    1987-01-01

    A key issue in designing and evaluating nuclear safeguards systems is how to validate safeguards effectiveness against a spectrum of potential threats. Safeguards effectiveness is measured by a performance indicator such as the probability of defeating an adversary attempting a malevolent act. Effectiveness validation means a testing program that provides sufficient evidence that the performance indicator is at an acceptable level. Traditional statistical program when numerous independent system trials are possible. However, within the safeguards environment, many situations arise for which traditional statistical approaches may be neither feasible nor appropriate. Such situations can occur, for example, when there are obvious constraints on the number of possible tests due to operational impacts and testing costs. Furthermore, these tests are usually simulations (e.g., staged force-on-force exercises) rather than actual tests, and the system is often modified after each test. Under such circumstances, it is difficult to make and justify inferences about system performance by using traditional statistical techniques. In this paper, the authors discuss several alternative quantitative techniques for validating system effectiveness. The techniques include: (1) minimizing the number of required tests using sequential testing; (2) combining data from models inspections and exercises using Bayesian statistics to improve inferences about system performance; and (3) using reliability growth and scenario modeling to help specify which safeguards elements and scenarios to test

  11. Validation testing of a soil macronutrient sensing system

    Science.gov (United States)

    Rapid on-site measurements of soil macronutrients (i.e., nitrogen, phosphorus, and potassium) are needed for site-specific crop management, where fertilizer nutrient application rates are adjusted spatially based on local requirements. This study reports on validation testing of a previously develop...

  12. Software Verification and Validation Test Report for the HEPA filter Differential Pressure Fan Interlock System

    International Nuclear Information System (INIS)

    ERMI, A.M.

    2000-01-01

    The HEPA Filter Differential Pressure Fan Interlock System PLC ladder logic software was tested using a Software Verification and Validation (VandV) Test Plan as required by the ''Computer Software Quality Assurance Requirements''. The purpose of his document is to report on the results of the software qualification

  13. Final Report - Spent Nuclear Fuel Retrieval System Manipulator System Cold Validation Testing

    International Nuclear Information System (INIS)

    D.R. Jackson; G.R. Kiebel

    1999-01-01

    Manipulator system cold validation testing (CVT) was performed in support of the Fuel Retrieval System (FRS) Sub-Project, a subtask of the Spent Nuclear Fuel Project at the Hanford Site in Richland, Washington. The FRS will be used to retrieve and repackage K-Basin Spent Nuclear Fuel (SNF) currently stored in old K-Plant storage basins. The FRS is required to retrieve full fuel canisters from the basin; clean the fuel elements inside the canister to remove excessive uranium corrosion products (or sludge); remove the contents from the canisters; and sort the resulting debris, scrap, and fuel for repackaging. The fuel elements and scrap will be collected in fuel storage and scrap baskets in preparation for loading into a multi canister overpack (MCO), while the debris is loaded into a debris bin and disposed of as solid waste. The FRS is composed of three major subsystems. The Manipulator Subsystem provides remote handling of fuel, scrap, and debris; the In-Pool Equipment subsystem performs cleaning of fuel and provides a work surface for handling materials; and the Remote Viewing Subsystem provides for remote viewing of the work area by operators. There are two complete and identical FRS systems, one to be installed in the K-West basin and one to be installed in the K-East basin. Another partial system will be installed in a cold test facility to provide for operator training

  14. Final Report - Spent Nuclear Fuel Retrieval System Manipulator System Cold Validation Testing

    Energy Technology Data Exchange (ETDEWEB)

    D.R. Jackson; G.R. Kiebel

    1999-08-24

    Manipulator system cold validation testing (CVT) was performed in support of the Fuel Retrieval System (FRS) Sub-Project, a subtask of the Spent Nuclear Fuel Project at the Hanford Site in Richland, Washington. The FRS will be used to retrieve and repackage K-Basin Spent Nuclear Fuel (SNF) currently stored in old K-Plant storage basins. The FRS is required to retrieve full fuel canisters from the basin; clean the fuel elements inside the canister to remove excessive uranium corrosion products (or sludge); remove the contents from the canisters; and sort the resulting debris, scrap, and fuel for repackaging. The fuel elements and scrap will be collected in fuel storage and scrap baskets in preparation for loading into a multi canister overpack (MCO), while the debris is loaded into a debris bin and disposed of as solid waste. The FRS is composed of three major subsystems. The Manipulator Subsystem provides remote handling of fuel, scrap, and debris; the In-Pool Equipment subsystem performs cleaning of fuel and provides a work surface for handling materials; and the Remote Viewing Subsystem provides for remote viewing of the work area by operators. There are two complete and identical FRS systems, one to be installed in the K-West basin and one to be installed in the K-East basin. Another partial system will be installed in a cold test facility to provide for operator training.

  15. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    Science.gov (United States)

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  16. A framework for the testing and validation of the I and C system based on a simulator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Jun; Kwon, Kee Choon; Lee, Jang Soo [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The I and C system for a nuclear power plant should be developed as a prototype or mock-up from the concept phase of the development process, and the function and performance of the computer system also have to be tested and validated. If possible, the developed prototype or mock-up could receive the signals of a normal or abnormal operation status of a nuclear power plant and generate the proper requirement output signal. Using these processes, it can be verified that the status of a plant is changed to the design state or the state needed by the plant operator. A simulation-based conformity evaluation platform is an environment that can automate the testing and validation actions. A traditional testing and validation method defines the static test requirements and extracts the input data from the defined requirement using IO signal generation devices. On the contrary, a simulation-based test method can generate the real calculated input data from a simulator and send the signals to the test devices directly. In this paper, we developed a framework that can conduct a conformity evaluation based on a simulator and implement the communication and monitoring program.

  17. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 3; Validation and Test Cases

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the third volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User s Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by validation studies that were done on three fan rigs. It concludes with recommended improvements and additional studies for BFaNS.

  18. Development of a Torque Sensor-Based Test Bed for Attitude Control System Verification and Validation

    Science.gov (United States)

    2017-12-30

    AFRL-RV-PS- AFRL-RV-PS- TR-2018-0008 TR-2018-0008 DEVELOPMENT OF A TORQUE SENSOR- BASED TEST BED FOR ATTITUDE CONTROL SYSTEM VERIFICATION AND...Sensor-Based Test Bed for Attitude Control System Verification & Validation 5a. CONTRACT NUMBER FA9453-15-1-0315 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...NUMBER 62601F 6. AUTHOR(S) Norman Fitz-Coy 5d. PROJECT NUMBER 4846 5e. TASK NUMBER PPM00015968 5f. WORK UNIT NUMBER EF125135 7. PERFORMING

  19. Validation test case generation based on safety analysis ontology

    International Nuclear Information System (INIS)

    Fan, Chin-Feng; Wang, Wen-Shing

    2012-01-01

    Highlights: ► Current practice in validation test case generation for nuclear system is mainly ad hoc. ► This study designs a systematic approach to generate validation test cases from a Safety Analysis Report. ► It is based on a domain-specific ontology. ► Test coverage criteria have been defined and satisfied. ► A computerized toolset has been implemented to assist the proposed approach. - Abstract: Validation tests in the current nuclear industry practice are typically performed in an ad hoc fashion. This study presents a systematic and objective method of generating validation test cases from a Safety Analysis Report (SAR). A domain-specific ontology was designed and used to mark up a SAR; relevant information was then extracted from the marked-up document for use in automatically generating validation test cases that satisfy the proposed test coverage criteria; namely, single parameter coverage, use case coverage, abnormal condition coverage, and scenario coverage. The novelty of this technique is its systematic rather than ad hoc test case generation from a SAR to achieve high test coverage.

  20. DTU PMU Laboratory Development - Testing and Validation

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE...... standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to follow known patterns and provide confirmation about the test system to confirm the design and settings....... In a nutshell, having 2 PMUs that observe same signals provides validation of the operation and flags questionable results with more certainty. Moreover, the performance and accuracy of the DTU-PMU is tested acquiring good and precise results, when compared with a commercial phasor measurement device, PMU-1....

  1. Validation testing of safety-critical software

    International Nuclear Information System (INIS)

    Kim, Hang Bae; Han, Jae Bok

    1995-01-01

    A software engineering process has been developed for the design of safety critical software for Wolsung 2/3/4 project to satisfy the requirements of the regulatory body. Among the process, this paper described the detail process of validation testing performed to ensure that the software with its hardware, developed by the design group, satisfies the requirements of the functional specification prepared by the independent functional group. To perform the tests, test facility and test software were developed and actual safety system computer was connected. Three kinds of test cases, i.e., functional test, performance test and self-check test, were programmed and run to verify each functional specifications. Test failures were feedback to the design group to revise the software and test results were analyzed and documented in the report to submit to the regulatory body. The test methodology and procedure were very efficient and satisfactory to perform the systematic and automatic test. The test results were also acceptable and successful to verify the software acts as specified in the program functional specification. This methodology can be applied to the validation of other safety-critical software. 2 figs., 2 tabs., 14 refs. (Author)

  2. Overview of CSNI separate effects tests validation matrix

    Energy Technology Data Exchange (ETDEWEB)

    Aksan, N. [Paul Scherrer Institute, Villigen (Switzerland); Auria, F.D. [Univ. of Pisa (Italy); Glaeser, H. [Gesellschaft fuer anlagen und Reaktorsicherheit, (GRS), Garching (Germany)] [and others

    1995-09-01

    An internationally agreed separate effects test (SET) Validation Matrix for thermal-hydraulic system codes has been established by a sub-group of the Task Group on Thermal Hydraulic System Behaviour as requested by the OECD/NEA Committee on Safety of Nuclear Installations (SCNI) Principal Working Group No. 2 on Coolant System Behaviour. The construction of such a Matrix is an attempt to collect together in a systematic way the best sets of openly available test data for code validation, assessment and improvement and also for quantitative code assessment with respect to quantification of uncertainties to the modeling of individual phenomena by the codes. The methodology, that has been developed during the process of establishing CSNI-SET validation matrix, was an important outcome of the work on SET matrix. In addition, all the choices which have been made from the 187 identified facilities covering the 67 phenomena will be investigated together with some discussions on the data base.

  3. Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System

    Science.gov (United States)

    Wincheski, Russell A.

    2007-01-01

    Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.

  4. Integrated Validation System for a Thermal-hydraulic System Code, TASS/SMR-S

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hee-Kyung; Kim, Hyungjun; Kim, Soo Hyoung; Hwang, Young-Dong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Hyeon-Soo [Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    Development including enhancement and modification of thermal-hydraulic system computer code is indispensable to a new reactor, SMART. Usually, a thermal-hydraulic system code validation is achieved by a comparison with the results of corresponding physical effect tests. In the reactor safety field, a similar concept, referred to as separate effect tests has been used for a long time. But there are so many test data for comparison because a lot of separate effect tests and integral effect tests are required for a code validation. It is not easy to a code developer to validate a computer code whenever a code modification is occurred. IVS produces graphs which shown the comparison the code calculation results with the corresponding test results automatically. IVS was developed for a validation of TASS/SMR-S code. The code validation could be achieved by a comparison code calculation results with corresponding test results. This comparison was represented as a graph for convenience. IVS is useful before release a new code version. The code developer can validate code result easily using IVS. Even during code development, IVS could be used for validation of code modification. The code developer could gain a confidence about his code modification easily and fast and could be free from tedious and long validation work. The popular software introduced in IVS supplies better usability and portability.

  5. VEHIL: a test facility for validation of fault management systems for advanced driver assistance systems

    NARCIS (Netherlands)

    Gietelink, O.J.; Ploeg, J.; Schutter, de B.; Verhaegen, M.H.

    2004-01-01

    We present a methodological approach for the validation of fault management systems for Advanced Driver Assistance Systems (ADAS). For the validation process the unique VEHIL facility, developed by TNO Automotive and currently situated in Helmond, The Netherlands, is applied. The VEHIL facility

  6. Optimal number of tests to achieve and validate product reliability

    International Nuclear Information System (INIS)

    Ahmed, Hussam; Chateauneuf, Alaa

    2014-01-01

    The reliability validation of engineering products and systems is mandatory for choosing the best cost-effective design among a series of alternatives. Decisions at early design stages have a large effect on the overall life cycle performance and cost of products. In this paper, an optimization-based formulation is proposed by coupling the costs of product design and validation testing, in order to ensure the product reliability with the minimum number of tests. This formulation addresses the question about the number of tests to be specified through reliability demonstration necessary to validate the product under appropriate confidence level. The proposed formulation takes into account the product cost, the failure cost and the testing cost. The optimization problem can be considered as a decision making system according to the hierarchy of structural reliability measures. The numerical examples show the interest of coupling design and testing parameters. - Highlights: • Coupled formulation for design and testing costs, with lifetime degradation. • Cost-effective testing optimization to achieve reliability target. • Solution procedure for nested aleatoric and epistemic variable spaces

  7. Validity of an Interactive Functional Reach Test.

    Science.gov (United States)

    Galen, Sujay S; Pardo, Vicky; Wyatt, Douglas; Diamond, Andrew; Brodith, Victor; Pavlov, Alex

    2015-08-01

    Videogaming platforms such as the Microsoft (Redmond, WA) Kinect(®) are increasingly being used in rehabilitation to improve balance performance and mobility. These gaming platforms do not have built-in clinical measures that offer clinically meaningful data. We have now developed software that will enable the Kinect sensor to assess a patient's balance using an interactive functional reach test (I-FRT). The aim of the study was to test the concurrent validity of the I-FRT and to establish the feasibility of implementing the I-FRT in a clinical setting. The concurrent validity of the I-FRT was tested among 20 healthy adults (mean age, 25.8±3.4 years; 14 women). The Functional Reach Test (FRT) was measured simultaneously by both the Kinect sensor using the I-FRT software and the Optotrak Certus(®) 3D motion-capture system (Northern Digital Inc., Waterloo, ON, Canada). The feasibility of implementing the I-FRT in a clinical setting was assessed by performing the I-FRT in 10 participants with mild balance impairments recruited from the outpatient physical therapy clinic (mean age, 55.8±13.5 years; four women) and obtaining their feedback using a NASA Task Load Index (NASA-TLX) questionnaire. There was moderate to good agreement between FRT measures made by the two measurement systems. The greatest agreement between the two measurement system was found with the Kinect sensor placed at a distance of 2.5 m [intraclass correlation coefficient (2,k)=0.786; PNASA/TLX questionnaire. FRT measures made using the Kinect sensor I-FRT software provides a valid clinical measure that can be used with the gaming platforms.

  8. Validity evidence based on test content.

    Science.gov (United States)

    Sireci, Stephen; Faulkner-Bond, Molly

    2014-01-01

    Validity evidence based on test content is one of the five forms of validity evidence stipulated in the Standards for Educational and Psychological Testing developed by the American Educational Research Association, American Psychological Association, and National Council on Measurement in Education. In this paper, we describe the logic and theory underlying such evidence and describe traditional and modern methods for gathering and analyzing content validity data. A comprehensive review of the literature and of the aforementioned Standards is presented. For educational tests and other assessments targeting knowledge and skill possessed by examinees, validity evidence based on test content is necessary for building a validity argument to support the use of a test for a particular purpose. By following the methods described in this article, practitioners have a wide arsenal of tools available for determining how well the content of an assessment is congruent with and appropriate for the specific testing purposes.

  9. Integral test facilities for validation of the performance of passive safety systems and natural circulation

    International Nuclear Information System (INIS)

    Choi, J. H.

    2010-10-01

    Passive safety systems are becoming an important component in advanced reactor designs. This has led to an international interest in examining natural circulation phenomena as this may play an important role in the operation of these passive safety systems. Understanding reactor system behaviour is a challenging process due to the complex interactions between components and associated phenomena. Properly scaled integral test facilities can be used to explore these complex interactions. In addition, system analysis computer codes can be used as predictive tools in understanding the complex reactor system behaviour. However, before the application of system analysis computer codes for reactor design, it is capability in making predictions needs to be validated against the experimental data from a properly scaled integral test facility. The IAEA has organized a coordinated research project (CRP) on natural circulation phenomena, modeling and reliability of passive systems that utilize natural circulation. This paper is a part of research results from this CRP and describes representative international integral test facilities that can be used for data collection for reactor types in which natural circulation may play an important role. Example experiments were described along with the analyses of these example cases in order to examine the ability of system codes to model the phenomena that are occurring in the test facilities. (Author)

  10. Mollusc reproductive toxicity tests - Development and validation of test guidelines

    DEFF Research Database (Denmark)

    Ducrot, Virginie; Holbech, Henrik; Kinnberg, Karin Lund

    . Draft standard operating procedures (SOPs) have been designed based upon literature and expert knowledge from project partners. Pre-validation studies have been implemented to validate the proposed test conditions and identify issues in performing the SOPs and analyzing test results. Pre-validation work......The Organisation for Economic Cooperation and Development is promoting the development and validation of mollusc toxicity tests within its test guidelines programme, eventually aiming for the standardization of mollusc apical toxicity tests. Through collaborative work between academia, industry...... and stakeholders, this study aims to develop innovative partial life-cycle tests on the reproduction of the freshwater gastropods Potamopyrgus antipodarum and Lymnaea stagnalis, which are relevant candidate species for the standardization of mollusc apical toxicity tests assessing reprotoxic effects of chemicals...

  11. Technique for unit testing of safety software verification and validation

    International Nuclear Information System (INIS)

    Li Duo; Zhang Liangju; Feng Junting

    2008-01-01

    The key issue arising from digitalization of the reactor protection system for nuclear power plant is how to carry out verification and validation (V and V), to demonstrate and confirm the software that performs reactor safety functions is safe and reliable. One of the most important processes for software V and V is unit testing, which verifies and validates the software coding based on concept design for consistency, correctness and completeness during software development. The paper shows a preliminary study on the technique for unit testing of safety software V and V, focusing on such aspects as how to confirm test completeness, how to establish test platform, how to develop test cases and how to carry out unit testing. The technique discussed here was successfully used in the work of unit testing on safety software of a digital reactor protection system. (authors)

  12. Validity Theory: Reform Policies, Accountability Testing, and Consequences

    Science.gov (United States)

    Chalhoub-Deville, Micheline

    2016-01-01

    Educational policies such as Race to the Top in the USA affirm a central role for testing systems in government-driven reform efforts. Such reform policies are often referred to as the global education reform movement (GERM). Changes observed with the GERM style of testing demand socially engaged validity theories that include consequential…

  13. Validating a UAV artificial intelligence control system using an autonomous test case generator

    Science.gov (United States)

    Straub, Jeremy; Huber, Justin

    2013-05-01

    The validation of safety-critical applications, such as autonomous UAV operations in an environment which may include human actors, is an ill posed problem. To confidence in the autonomous control technology, numerous scenarios must be considered. This paper expands upon previous work, related to autonomous testing of robotic control algorithms in a two dimensional plane, to evaluate the suitability of similar techniques for validating artificial intelligence control in three dimensions, where a minimum level of airspeed must be maintained. The results of human-conducted testing are compared to this automated testing, in terms of error detection, speed and testing cost.

  14. Continuous validation of ASTEC containment models and regression testing

    International Nuclear Information System (INIS)

    Nowack, Holger; Reinke, Nils; Sonnenkalb, Martin

    2014-01-01

    The focus of the ASTEC (Accident Source Term Evaluation Code) development at GRS is primarily on the containment module CPA (Containment Part of ASTEC), whose modelling is to a large extent based on the GRS containment code COCOSYS (COntainment COde SYStem). Validation is usually understood as the approval of the modelling capabilities by calculations of appropriate experiments done by external users different from the code developers. During the development process of ASTEC CPA, bugs and unintended side effects may occur, which leads to changes in the results of the initially conducted validation. Due to the involvement of a considerable number of developers in the coding of ASTEC modules, validation of the code alone, even if executed repeatedly, is not sufficient. Therefore, a regression testing procedure has been implemented in order to ensure that the initially obtained validation results are still valid with succeeding code versions. Within the regression testing procedure, calculations of experiments and plant sequences are performed with the same input deck but applying two different code versions. For every test-case the up-to-date code version is compared to the preceding one on the basis of physical parameters deemed to be characteristic for the test-case under consideration. In the case of post-calculations of experiments also a comparison to experimental data is carried out. Three validation cases from the regression testing procedure are presented within this paper. The very good post-calculation of the HDR E11.1 experiment shows the high quality modelling of thermal-hydraulics in ASTEC CPA. Aerosol behaviour is validated on the BMC VANAM M3 experiment, and the results show also a very good agreement with experimental data. Finally, iodine behaviour is checked in the validation test-case of the THAI IOD-11 experiment. Within this test-case, the comparison of the ASTEC versions V2.0r1 and V2.0r2 shows how an error was detected by the regression testing

  15. A listening test system for automative audio

    DEFF Research Database (Denmark)

    Bech, Søren; Gulbol, Mehmet-Ali; Martin, Geoff

    2005-01-01

    This paper describes two listening tests that were performed to provide initial validation of an auralisation system (see Part 1) to mimic the acoustics of a car interior. The validation is based on a comparison of results from an in-car listening test and another test using the auralisation system...... and recordings of the stimuli used for the in-car test. The music samples for the test were chosen from a database of various CODEC examples from a previous extensive ITU test to validate the ITU-R BS.1387-1 standard....

  16. Validation of SSC using the FFTF natural-circulation tests

    International Nuclear Information System (INIS)

    Horak, W.C.; Guppy, J.G.; Kennett, R.J.

    1982-01-01

    As part of the Super System Code (SSC) validation program, the 100% power FFTF natural circulation test has been simulated using SSC. A detailed 19 channel, 2 loop model was used in SSC. Comparisons showed SSC calculations to be in good agreement with the Fast Flux Test Facility (FFTF), test data. Simulation of the test was obtained in real time

  17. Validation of WIMS-AECL/(MULTICELL)/RFSP system by the results of phase-B test at Wolsung-II unit

    Energy Technology Data Exchange (ETDEWEB)

    Hong, In Seob; Min, Byung Joo; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-03-01

    The object of this study is the validation of WIMS-AECL lattice code which has been proposed for the substitution of POWDERPUFS-V(PPV) code. For the validation of this code, WIMS-AECL/(MULTICELL)/RFSP (lattice calculation/(incremental cross section calculation)/core calculation) code system has been used for the Post-Simulation of Phase-B physics Test at Wolsung-II unit. This code system had been used for the Wolsong-I and Point Lepraeu reactors, but after a few modifications of WIMS-AECL input values for Wolsong-II, the results of WIMS-AECL/RFSP code calculations are much improved to those of the old ones. Most of the results show good estimation except moderator temperature coefficient test. And the verification of this result must be done, which is one of the further work. 6 figs., 15 tabs. (Author)

  18. Development and testing of an integrated signal validation system for nuclear power plants

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Kerlin, T.W.; Gaudio, P.J. Jr.

    1989-09-01

    Since the incident at Three Mile Island unit 2, computerized plant status display, implementation of human factors in control room design, and plant monitoring based on expert system technology have seen a tremendous growth. One such proposed operator assist device is a plant signal validation system. This system is used to check the consistency of redundant measurements (sensors) of selected process variables, estimate their expect values from plant-wide data, and detect, isolate and characterize the type of anomaly in the instrument channel outputs. In large process control systems signals from several hundred instrument channels are routed via data highways to control systems, protection (safety) systems and plant monitoring systems. The need of automated signal validation is necessary because of the large amount of information available, and as a result the operator's inability to validate information from many diverse sources. This is also useful for improved plant control (minimize challenges on control systems), minimizing plant downtime, and for predictive maintenance advising. 107 refs., 56 figs., 6 tabs

  19. Solar Sail Models and Test Measurements Correspondence for Validation Requirements Definition

    Science.gov (United States)

    Ewing, Anthony; Adams, Charles

    2004-01-01

    Solar sails are being developed as a mission-enabling technology in support of future NASA science missions. Current efforts have advanced solar sail technology sufficient to justify a flight validation program. A primary objective of this activity is to test and validate solar sail models that are currently under development so that they may be used with confidence in future science mission development (e.g., scalable to larger sails). Both system and model validation requirements must be defined early in the program to guide design cycles and to ensure that relevant and sufficient test data will be obtained to conduct model validation to the level required. A process of model identification, model input/output documentation, model sensitivity analyses, and test measurement correspondence is required so that decisions can be made to satisfy validation requirements within program constraints.

  20. Design for validation: An approach to systems validation

    Science.gov (United States)

    Carter, William C.; Dunham, Janet R.; Laprie, Jean-Claude; Williams, Thomas; Howden, William; Smith, Brian; Lewis, Carl M. (Editor)

    1989-01-01

    Every complex system built is validated in some manner. Computer validation begins with review of the system design. As systems became too complicated for one person to review, validation began to rely on the application of adhoc methods by many individuals. As the cost of the changes mounted and the expense of failure increased, more organized procedures became essential. Attempts at devising and carrying out those procedures showed that validation is indeed a difficult technical problem. The successful transformation of the validation process into a systematic series of formally sound, integrated steps is necessary if the liability inherent in the future digita-system-based avionic and space systems is to be minimized. A suggested framework and timetable for the transformtion are presented. Basic working definitions of two pivotal ideas (validation and system life-cyle) are provided and show how the two concepts interact. Many examples are given of past and present validation activities by NASA and others. A conceptual framework is presented for the validation process. Finally, important areas are listed for ongoing development of the validation process at NASA Langley Research Center.

  1. Generic test platform for representative tests of safety I/C systems - 15546

    International Nuclear Information System (INIS)

    Fourestie, B.; Kuck, H.; Richter, J.; Rieche, S.; Waitz, M.

    2015-01-01

    In compliance with the IEC 61513 safety Instrumentation and Control (I/C) systems must be successfully validated in their final configuration prior to installation on site and commissioning. However the contingent need for modifications during system validation activities or subsequently during the commissioning phase may entail long and costly re-engineering of the I/C systems. With the view to ease these possible modifications, a Generic Test Platform has been developed by AREVA which allows combining a real I/C system subpart with an emulation server. This platform provides a faithful representation of the I/C System allowing crediting the validation test results carried out on this platform. (authors)

  2. S.E.T., CSNI Separate Effects Test Facility Validation Matrix

    International Nuclear Information System (INIS)

    1997-01-01

    1 - Description of test facility: The SET matrix of experiments is suitable for the developmental assessment of thermal-hydraulics transient system computer codes by selecting individual tests from selected facilities, relevant to each phenomena. Test facilities differ from one another in geometrical dimensions, geometrical configuration and operating capabilities or conditions. Correlation between SET facility and phenomena were calculated on the basis of suitability for model validation (which means that a facility is designed in such a way as to stimulate the phenomena assumed to occur in a plant and is sufficiently instrumented); limited suitability for model variation (which means that a facility is designed in such a way as to stimulate the phenomena assumed to occur in a plant but has problems associated with imperfect scaling, different test fluids or insufficient instrumentation); and unsuitability for model validation. 2 - Description of test: Whereas integral experiments are usually designed to follow the behaviour of a reactor system in various off-normal or accident transients, separate effects tests focus on the behaviour of a single component, or on the characteristics of one thermal-hydraulic phenomenon. The construction of a separate effects test matrix is an attempt to collect together the best sets of openly available test data for code validation, assessment and improvement, from the wide range of experiments that have been carried out world-wide in the field of thermal hydraulics. In all, 2094 tests are included in the SET matrix

  3. Development and validation of climate change system thinking instrument (CCSTI) for measuring system thinking on climate change content

    Science.gov (United States)

    Meilinda; Rustaman, N. Y.; Firman, H.; Tjasyono, B.

    2018-05-01

    The Climate Change System Thinking Instrument (CCSTI) is developed to measure a system thinking ability in the concept of climate change. CCSTI is developed in four phase’s development including instrument draft development, validation and evaluation including readable material test, expert validation, and field test. The result of field test is analyzed by looking at the readability score in Cronbach’s alpha test. Draft instrument is tested on college students majoring in Biology Education, Physics Education, and Chemistry Education randomly with a total number of 80 college students. Score of Content Validation Index at 0.86, which means that the CCSTI developed are categorized as very appropriate with question indicators and Cronbach’s alpha about 0.605 which mean categorized undesirable to minimal acceptable. From 45 questions of system thinking, there are 37 valid questions spread in four indicators of system thinking, which are system thinking phase I (pre-requirement), system thinking phase II (basic), system thinking phase III (intermediate), and system thinking phase IV (coherent expert).

  4. Validation of the thermal-hydraulic system code ATHLET based on selected pressure drop and void fraction BFBT tests

    Energy Technology Data Exchange (ETDEWEB)

    Di Marcello, Valentino, E-mail: valentino.marcello@kit.edu; Escalante, Javier Jimenez; Espinoza, Victor Sanchez

    2015-07-15

    Highlights: • Simulation of BFBT-BWR steady-state and transient tests with ATHLET. • Validation of thermal-hydraulic models based on pressure drops and void fraction measurements. • TRACE system code is used for the comparative study. • Predictions result in a good agreement with the experiments. • Discrepancies are smaller or comparable with respect to the measurements uncertainty. - Abstract: Validation and qualification of thermal-hydraulic system codes based on separate effect tests are essential for the reliability of numerical tools when applied to nuclear power plant analyses. To this purpose, the Institute for Neutron Physics and Reactor Technology (INR) at the Karlsruhe Institute of Technology (KIT) is involved in various validation and qualification activities of different CFD, sub-channel and system codes. In this paper, the capabilities of the thermal-hydraulic code ATHLET are assessed based on the experimental results provided within the NUPEC BFBT benchmark related to key Boiling Water Reactors (BWR) phenomena. Void fraction and pressure drops measurements in the BFBT bundle performed under steady-state and transient conditions which are representative for e.g. turbine trip and recirculation pump trip events, are compared with the numerical results of ATHLET. The comparison of code predictions with the BFBT data has shown good agreement given the experimental uncertainty and the results are consistent with the trends obtained with similar thermal-hydraulic codes.

  5. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  6. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  7. Validation of Helicopter Gear Condition Indicators Using Seeded Fault Tests

    Science.gov (United States)

    Dempsey, Paula; Brandon, E. Bruce

    2013-01-01

    A "seeded fault test" in support of a rotorcraft condition based maintenance program (CBM), is an experiment in which a component is tested with a known fault while health monitoring data is collected. These tests are performed at operating conditions comparable to operating conditions the component would be exposed to while installed on the aircraft. Performance of seeded fault tests is one method used to provide evidence that a Health Usage Monitoring System (HUMS) can replace current maintenance practices required for aircraft airworthiness. Actual in-service experience of the HUMS detecting a component fault is another validation method. This paper will discuss a hybrid validation approach that combines in service-data with seeded fault tests. For this approach, existing in-service HUMS flight data from a naturally occurring component fault will be used to define a component seeded fault test. An example, using spiral bevel gears as the targeted component, will be presented. Since the U.S. Army has begun to develop standards for using seeded fault tests for HUMS validation, the hybrid approach will be mapped to the steps defined within their Aeronautical Design Standard Handbook for CBM. This paper will step through their defined processes, and identify additional steps that may be required when using component test rig fault tests to demonstrate helicopter CI performance. The discussion within this paper will provide the reader with a better appreciation for the challenges faced when defining a seeded fault test for HUMS validation.

  8. Validation of the mathematical model of the NAPS PHT system flow with test data

    International Nuclear Information System (INIS)

    Rajesh Kumar, K.; Vani, K.; Chakraborty, G.; Venkat Raj, V.

    1994-01-01

    A dynamic analysis code to predict the time dependent behaviour of the reactor coolant system flow following the tripping and starting of Primary Circulating Pumps in the different operating modes has been developed for Indian Pressurised Heavy Water Reactor (PHWR) type power plants. The model is comprised of reactor coolant momentum equation, Primary Heat Transport (PHT) pump dynamic equation and pump characteristics. This model forms one of the modules of the integrated system code being developed for transient analysis of 220 MWe PHWR power plants. The Narora Atomic Power Station (NAPS) PHT system flow transient results for different combinations of pump operation predicted by the model have been compared with the experimental data obtained from a test carried out in NAPS-2 for validation of the model. The predicted results are in good agreement with the experimental data. (author). 3 refs., 5 figs

  9. Validation of Symptom Validity Tests Using a "Child-model" of Adult Cognitive Impairments

    NARCIS (Netherlands)

    Rienstra, A.; Spaan, P. E. J.; Schmand, B.

    2010-01-01

    Validation studies of symptom validity tests (SVTs) in children are uncommon. However, since children's cognitive abilities are not yet fully developed, their performance may provide additional support for the validity of these measures in adult populations. Four SVTs, the Test of Memory Malingering

  10. Engineering Software Suite Validates System Design

    Science.gov (United States)

    2007-01-01

    EDAptive Computing Inc.'s (ECI) EDAstar engineering software tool suite, created to capture and validate system design requirements, was significantly funded by NASA's Ames Research Center through five Small Business Innovation Research (SBIR) contracts. These programs specifically developed Syscape, used to capture executable specifications of multi-disciplinary systems, and VectorGen, used to automatically generate tests to ensure system implementations meet specifications. According to the company, the VectorGen tests considerably reduce the time and effort required to validate implementation of components, thereby ensuring their safe and reliable operation. EDASHIELD, an additional product offering from ECI, can be used to diagnose, predict, and correct errors after a system has been deployed using EDASTAR -created models. Initial commercialization for EDASTAR included application by a large prime contractor in a military setting, and customers include various branches within the U.S. Department of Defense, industry giants like the Lockheed Martin Corporation, Science Applications International Corporation, and Ball Aerospace and Technologies Corporation, as well as NASA's Langley and Glenn Research Centers

  11. Construct Validity of Neuropsychological Tests in Schizophrenia.

    Science.gov (United States)

    Allen, Daniel N.; Aldarondo, Felito; Goldstein, Gerald; Huegel, Stephen G.; Gilbertson, Mark; van Kammen, Daniel P.

    1998-01-01

    The construct validity of neuropsychological tests in patients with schizophrenia was studied with 39 patients who were evaluated with a battery of six tests assessing attention, memory, and abstract reasoning abilities. Results support the construct validity of the neuropsychological tests in patients with schizophrenia. (SLD)

  12. The validation of language tests

    African Journals Online (AJOL)

    KATEVG

    Stellenbosch Papers in Linguistics, Vol. ... validation is necessary because of the major impact which test results can have on the many ... Messick (1989: 20) introduces his much-quoted progressive matrix (cf. table 1), which ... argue that current accounts of validity only superficially address theories of measurement.

  13. Validation of symptom validity tests using a "child-model" of adult cognitive impairments

    NARCIS (Netherlands)

    Rienstra, A.; Spaan, P.E.J.; Schmand, B.

    2010-01-01

    Validation studies of symptom validity tests (SVTs) in children are uncommon. However, since children’s cognitive abilities are not yet fully developed, their performance may provide additional support for the validity of these measures in adult populations. Four SVTs, the Test of Memory Malingering

  14. Validating the JobFit system functional assessment method

    Energy Technology Data Exchange (ETDEWEB)

    Jenny Legge; Robin Burgess-Limerick

    2007-05-15

    Workplace injuries are costing the Australian coal mining industry and its communities $410 Million a year. This ACARP study aims to meet those demands by developing a safe, reliable and valid pre-employment functional assessment tool. All JobFit System Pre-Employment Functional Assessments (PEFAs) consist of a musculoskeletal screen, balance test, aerobic fitness test and job-specific postural tolerances and material handling tasks. The results of each component are compared to the applicant's job demands and an overall PEFA score between 1 and 4 is given with 1 being the better score. The reliability study and validity study were conducted concurrently. The reliability study examined test-retest, intra-tester and inter-tester reliability of the JobFit System Functional Assessment Method. Overall, good to excellent reliability was found, which was sufficient to be used for comparison with injury data for determining the validity of the assessment. The overall assessment score and material handling tasks had the greatest reliability. The validity study compared the assessment results of 336 records from a Queensland underground and open cut coal mine with their injury records. A predictive relationship was found between PEFA score and the risk of a back/trunk/shoulder injury from manual handling. An association was also found between PEFA score of 1 and increased length of employment. Lower aerobic fitness test results had an inverse relationship with injury rates. The study found that underground workers, regardless of PEFA score, were more likely to have an injury when compared to other departments. No relationship was found between age and risk of injury. These results confirm the validity of the JobFit System Functional Assessment method.

  15. Testing the McSad depression specific classification system in patients with somatic conditions: validity and performance.

    Science.gov (United States)

    Papageorgiou, Katerina; Vermeulen, Karin M; Schroevers, Maya J; Buskens, Erik; Ranchor, Adelita V

    2013-07-26

    Valuations of depression are useful to evaluate depression interventions offered to patients with chronic somatic conditions. The only classification system to describe depression developed specifically for valuation purposes is the McSad, but it has not been used among somatic patients. The aim of this study was to test the construct validity of the McSad among diabetes and cancer patients and then to compare the McSad to the commonly used EuroQol - 5 Dimensions (EQ-5DTM) classification system. The comparison was expected to shed light on their capacity to reflect the range of depression states experienced by somatic patients. Cross-sectional data were collected online from 114 diabetes and 195 cancer patients; additionally, 241 cancer patients completed part of the survey on paper. Correlational analyses were performed to test the construct validity. Specifically, we hypothesized high correlations of the McSad domains with depression (Center for Epidemiological Studies Depression Scale (CES-D) and the Patient Health Questionnaire (PHQ-9)). We also expected low/moderate correlations with self-esteem (Rosenberg Self-Esteem scale - RSE) and extraversion (Eysenck Personality Questionnaire Extraversion scale - EPQ-e). Multiple linear regression analyses were run so that the proportion of variance in depression scores (CES-D, PHQ-9) explained by the McSad could be compared to the proportion explained by the EQ-5D classification system. As expected, among all patients groups, we found moderate to high correlations for the McSad domains with the CES-D (.41 to .70) and the PHQ-9 (.52 to .76); we also found low to moderate correlations with the RSE (-.21 to .-48) and the EPQ-e (.18 to .31). Linear regression analyses showed that the McSad explained a greater proportion of variance in depression (CES-D, PHQ-9) (Diabetes: 73%, 82%; Cancer: 72%, 72%) than the EQ-5D classification system (Diabetes: 47%, 59%; Cancer: 51%, 47%). Findings support the construct validity of the Mc

  16. Validity of Sensory Systems as Distinct Constructs

    OpenAIRE

    Su, Chia-Ting; Parham, L. Diane

    2014-01-01

    Confirmatory factor analysis testing whether sensory questionnaire items represented distinct sensory system constructs found, using data from two age groups, that such constructs can be measured validly using questionnaire data.

  17. Validity of a cross-specialty test in basic laparoscopic techniques (TABLT)

    DEFF Research Database (Denmark)

    Thinggaard, Ebbe; Bjerrum, Flemming; Strandbygaard, Jeanett

    2015-01-01

    . The aim of this study was to establish validity evidence for the Training and Assessment of Basic Laparoscopic Techniques (TABLT) test, a tablet-based training system. METHODS: Laparoscopic surgeons and trainees were recruited from departments of general surgery, gynaecology and urology. Participants...... included novice, intermediate and experienced surgeons. All participants performed the TABLT test. Performance scores were calculated based on time taken and errors made. Evidence of validity was explored using a contemporary framework of validity. RESULTS: Some 60 individuals participated. The TABLT...... was shown to be reliable, with an intraclass correlation coefficient of 0·99 (P value of 0·73 (P 

  18. Validation of the U.S. NRC coupled code system TRITON/TRACE/PARCS with the special power excursion reactor test III (SPERT III)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, R. C.; Xu, Y.; Downar, T. [Dept. of Nuclear Engineering and Radiological Sciences, Univ. of Michigan, Ann Arbor, MI 48104 (United States); Hudson, N. [RES Div., U.S. NRC, Rockville, MD (United States)

    2012-07-01

    The Special Power Excursion Reactor Test III (SPERT III) was a series of reactivity insertion experiments conducted in the 1950's. This paper describes the validation of the U.S. NRC Coupled Code system TRITON/PARCS/TRACE to simulate reactivity insertion accidents (RIA) by using several of the SPERT III tests. The work here used the SPERT III E-core configuration tests in which the RIA was initiated by ejecting a control rod. The resulting super-prompt reactivity excursion and negative reactivity feedback produced the familiar bell shaped power increase and decrease. The energy deposition during such a power peak has important safety consequences and provides validation basis for core coupled multi-physics codes. The transients of five separate tests are used to benchmark the PARCS/TRACE coupled code. The models were thoroughly validated using the original experiment documentation. (authors)

  19. 15 CFR 995.27 - Format validation software testing.

    Science.gov (United States)

    2010-01-01

    ... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying... specification. These tests may be combined with testing of the conversion software. ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Format validation software testing...

  20. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

    Directory of Open Access Journals (Sweden)

    Jing Cao

    2017-12-01

    Full Text Available Background: Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc. Methods: Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Results: Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Conclusion: Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. Impact of the study: This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing. Keywords: Epoc, Capillary, Transport, Blood gas, Point of care

  1. Development of knowledgebase system for assisting signal validation scheme design

    International Nuclear Information System (INIS)

    Kitamura, M.; Baba, T.; Washio, T.; Sugiyama, K.

    1987-01-01

    The purpose of this study is to develop a knowledgebase system to be used as a tool for designing signal validation schemes. The outputs from the signal validation scheme can be used as; (1) auxiliary signals for detecting sensor failures, (2) inputs to advanced instrumentation such as disturbance analysis and diagnosis system or safety parameter display system, and (3) inputs to digital control systems. Conventional signal validation techniques such as comparison of redundant sensors, limit checking, and calibration tests have been employed in nuclear power plants. However, these techniques have serious drawbacks, e.g. needs for extra sensors, vulnerability to common mode failures, limited applicability to continuous monitoring, etc. To alleviate these difficulties, a new signal validation technique has been developed by using the methods called analytic redundancy and parity space. Although the new technique has been proved feasible as far as preliminary tests are concerned, further developments should be made in order to enhance its practical applicability

  2. Validation of the Information/Communications Technology Literacy Test

    Science.gov (United States)

    2016-10-01

    Technical Report 1360 Validation of the Information /Communications Technology Literacy Test D. Matthew Trippe Human Resources Research...TITLE AND SUBTITLE Validation of the Information /Communications Technology Literacy Test 5a. CONTRACT OR GRANT NUMBER W91WAS-09-D-0013 5b...validate a measure of cyber aptitude, the Information /Communications Technology Literacy Test (ICTL), in predicting trainee performance in Information

  3. Validity and validation of expert (Q)SAR systems.

    Science.gov (United States)

    Hulzebos, E; Sijm, D; Traas, T; Posthumus, R; Maslankiewicz, L

    2005-08-01

    At a recent workshop in Setubal (Portugal) principles were drafted to assess the suitability of (quantitative) structure-activity relationships ((Q)SARs) for assessing the hazards and risks of chemicals. In the present study we applied some of the Setubal principles to test the validity of three (Q)SAR expert systems and validate the results. These principles include a mechanistic basis, the availability of a training set and validation. ECOSAR, BIOWIN and DEREK for Windows have a mechanistic or empirical basis. ECOSAR has a training set for each QSAR. For half of the structural fragments the number of chemicals in the training set is >4. Based on structural fragments and log Kow, ECOSAR uses linear regression to predict ecotoxicity. Validating ECOSAR for three 'valid' classes results in predictivity of > or = 64%. BIOWIN uses (non-)linear regressions to predict the probability of biodegradability based on fragments and molecular weight. It has a large training set and predicts non-ready biodegradability well. DEREK for Windows predictions are supported by a mechanistic rationale and literature references. The structural alerts in this program have been developed with a training set of positive and negative toxicity data. However, to support the prediction only a limited number of chemicals in the training set is presented to the user. DEREK for Windows predicts effects by 'if-then' reasoning. The program predicts best for mutagenicity and carcinogenicity. Each structural fragment in ECOSAR and DEREK for Windows needs to be evaluated and validated separately.

  4. Validation of Alternative In Vitro Methods to Animal Testing: Concepts, Challenges, Processes and Tools.

    Science.gov (United States)

    Griesinger, Claudius; Desprez, Bertrand; Coecke, Sandra; Casey, Warren; Zuang, Valérie

    This chapter explores the concepts, processes, tools and challenges relating to the validation of alternative methods for toxicity and safety testing. In general terms, validation is the process of assessing the appropriateness and usefulness of a tool for its intended purpose. Validation is routinely used in various contexts in science, technology, the manufacturing and services sectors. It serves to assess the fitness-for-purpose of devices, systems, software up to entire methodologies. In the area of toxicity testing, validation plays an indispensable role: "alternative approaches" are increasingly replacing animal models as predictive tools and it needs to be demonstrated that these novel methods are fit for purpose. Alternative approaches include in vitro test methods, non-testing approaches such as predictive computer models up to entire testing and assessment strategies composed of method suites, data sources and decision-aiding tools. Data generated with alternative approaches are ultimately used for decision-making on public health and the protection of the environment. It is therefore essential that the underlying methods and methodologies are thoroughly characterised, assessed and transparently documented through validation studies involving impartial actors. Importantly, validation serves as a filter to ensure that only test methods able to produce data that help to address legislative requirements (e.g. EU's REACH legislation) are accepted as official testing tools and, owing to the globalisation of markets, recognised on international level (e.g. through inclusion in OECD test guidelines). Since validation creates a credible and transparent evidence base on test methods, it provides a quality stamp, supporting companies developing and marketing alternative methods and creating considerable business opportunities. Validation of alternative methods is conducted through scientific studies assessing two key hypotheses, reliability and relevance of the

  5. Test-driven verification/validation of model transformations

    Institute of Scientific and Technical Information of China (English)

    László LENGYEL; Hassan CHARAF

    2015-01-01

    Why is it important to verify/validate model transformations? The motivation is to improve the quality of the trans-formations, and therefore the quality of the generated software artifacts. Verified/validated model transformations make it possible to ensure certain properties of the generated software artifacts. In this way, verification/validation methods can guarantee different requirements stated by the actual domain against the generated/modified/optimized software products. For example, a verified/ validated model transformation can ensure the preservation of certain properties during the model-to-model transformation. This paper emphasizes the necessity of methods that make model transformation verified/validated, discusses the different scenarios of model transformation verification and validation, and introduces the principles of a novel test-driven method for verifying/ validating model transformations. We provide a solution that makes it possible to automatically generate test input models for model transformations. Furthermore, we collect and discuss the actual open issues in the field of verification/validation of model transformations.

  6. Validity and reliability of the NAB Naming Test.

    Science.gov (United States)

    Sachs, Bonnie C; Rush, Beth K; Pedraza, Otto

    2016-05-01

    Confrontation naming is commonly assessed in neuropsychological practice, but few standardized measures of naming exist and those that do are susceptible to the effects of education and culture. The Neuropsychological Assessment Battery (NAB) Naming Test is a 31-item measure used to assess confrontation naming. Despite adequate psychometric information provided by the test publisher, there has been limited independent validation of the test. In this study, we investigated the convergent and discriminant validity, internal consistency, and alternate forms reliability of the NAB Naming Test in a sample of adults (Form 1: n = 247, Form 2: n = 151) clinically referred for neuropsychological evaluation. Results indicate adequate-to-good internal consistency and alternate forms reliability. We also found strong convergent validity as demonstrated by relationships with other neurocognitive measures. We found preliminary evidence that the NAB Naming Test demonstrates a more pronounced ceiling effect than other commonly used measures of naming. To our knowledge, this represents the largest published independent validation study of the NAB Naming Test in a clinical sample. Our findings suggest that the NAB Naming Test demonstrates adequate validity and reliability and merits consideration in the test arsenal of clinical neuropsychologists.

  7. Validity and Reliability Testing of an e-learning Questionnaire for Chemistry Instruction

    Science.gov (United States)

    Guspatni, G.; Kurniawati, Y.

    2018-04-01

    The aim of this paper is to examine validity and reliability of a questionnaire used to evaluate e-learning implementation in chemistry instruction. 48 questionnaires were filled in by students who had studied chemistry through e-learning system. The questionnaire consisted of 20 indicators evaluating students’ perception on using e-learning. Parametric testing was done as data were assumed to follow normal distribution. Item validity of the questionnaire was examined through item-total correlation using Pearson’s formula while its reliability was assessed with Cronbach’s alpha formula. Moreover, convergent validity was assessed to see whether indicators building a factor had theoretically the same underlying construct. The result of validity testing revealed 19 valid indicators while the result of reliability testing revealed Cronbach’s alpha value of .886. The result of factor analysis showed that questionnaire consisted of five factors, and each of them had indicators building the same construct. This article shows the importance of factor analysis to get a construct valid questionnaire before it is used as research instrument.

  8. Is outdoor use of the six-minute walk test with a global positioning system in stroke patients' own neighbourhoods reproducible and valid?

    NARCIS (Netherlands)

    Wevers, L.E.; Kwakkel, G.; van de Port, I.G.

    2011-01-01

    Objective: To examine the reproducibility, responsiveness and concurrent validity of the six-minute walk test (6MWT) when tested outdoors in patients' own neighbourhoods using a global positioning system (GPS) or a measuring wheel. Methods: A total of 27 chronic stroke patients, discharged to their

  9. Cyber-Physical Energy Systems Modeling, Test Specification, and Co-Simulation Based Testing

    DEFF Research Database (Denmark)

    van der Meer, A. A.; Palensky, P.; Heussen, Kai

    2017-01-01

    The gradual deployment of intelligent and coordinated devices in the electrical power system needs careful investigation of the interactions between the various domains involved. Especially due to the coupling between ICT and power systems a holistic approach for testing and validating is required....... Taking existing (quasi-) standardised smart grid system and test specification methods as a starting point, we are developing a holistic testing and validation approach that allows a very flexible way of assessing the system level aspects by various types of experiments (including virtual, real......, and mixed lab settings). This paper describes the formal holistic test case specification method and applies it to a particular co-simulation experimental setup. The various building blocks of such a simulation (i.e., FMI, mosaik, domain-specific simulation federates) are covered in more detail...

  10. ExEP yield modeling tool and validation test results

    Science.gov (United States)

    Morgan, Rhonda; Turmon, Michael; Delacroix, Christian; Savransky, Dmitry; Garrett, Daniel; Lowrance, Patrick; Liu, Xiang Cate; Nunez, Paul

    2017-09-01

    EXOSIMS is an open-source simulation tool for parametric modeling of the detection yield and characterization of exoplanets. EXOSIMS has been adopted by the Exoplanet Exploration Programs Standards Definition and Evaluation Team (ExSDET) as a common mechanism for comparison of exoplanet mission concept studies. To ensure trustworthiness of the tool, we developed a validation test plan that leverages the Python-language unit-test framework, utilizes integration tests for selected module interactions, and performs end-to-end crossvalidation with other yield tools. This paper presents the test methods and results, with the physics-based tests such as photometry and integration time calculation treated in detail and the functional tests treated summarily. The test case utilized a 4m unobscured telescope with an idealized coronagraph and an exoplanet population from the IPAC radial velocity (RV) exoplanet catalog. The known RV planets were set at quadrature to allow deterministic validation of the calculation of physical parameters, such as working angle, photon counts and integration time. The observing keepout region was tested by generating plots and movies of the targets and the keepout zone over a year. Although the keepout integration test required the interpretation of a user, the test revealed problems in the L2 halo orbit and the parameterization of keepout applied to some solar system bodies, which the development team was able to address. The validation testing of EXOSIMS was performed iteratively with the developers of EXOSIMS and resulted in a more robust, stable, and trustworthy tool that the exoplanet community can use to simulate exoplanet direct-detection missions from probe class, to WFIRST, up to large mission concepts such as HabEx and LUVOIR.

  11. An alternative to the balance error scoring system: using a low-cost balance board to improve the validity/reliability of sports-related concussion balance testing.

    Science.gov (United States)

    Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J

    2014-05-01

    Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.

  12. Towards a foundation for holistic power system validation and testing

    DEFF Research Database (Denmark)

    Blank, M.; Lehnhoff, S.; Heussen, Kai

    2016-01-01

    , and intelligent solutions for system operation have transformed the power system into a smart grid. To support the development process of smart grid solutions on system level they have to be tested in a holistic manner covering the multi-domain aspect of a such complex systems. This paper introduces the concept...... of holistic power system testing and discuss first steps towards a corresponding methodology that is being developed in the European ERIGrid research infrastructure project....

  13. Structural system identification: Structural dynamics model validation

    Energy Technology Data Exchange (ETDEWEB)

    Red-Horse, J.R.

    1997-04-01

    Structural system identification is concerned with the development of systematic procedures and tools for developing predictive analytical models based on a physical structure`s dynamic response characteristics. It is a multidisciplinary process that involves the ability (1) to define high fidelity physics-based analysis models, (2) to acquire accurate test-derived information for physical specimens using diagnostic experiments, (3) to validate the numerical simulation model by reconciling differences that inevitably exist between the analysis model and the experimental data, and (4) to quantify uncertainties in the final system models and subsequent numerical simulations. The goal of this project was to develop structural system identification techniques and software suitable for both research and production applications in code and model validation.

  14. Automated Testing System for a CAN Communication Circuit

    Directory of Open Access Journals (Sweden)

    PRUTIANU, F.

    2012-05-01

    Full Text Available The paper presents a method for validation/testing a control area network (CAN communication circuit used in all electronic control units (ECUs developed in automotive industry after 2000. Using a specific hardware configuration and remotely controlled by LabVIEW. The author's presents their own vision regarding operational software algorithm implementation and integration / execution of some test cases in order to validate a CAN circuit. Using this method, it is possible to validate/test CAN hardware circuits in a short time and with the possibility of saving the test results. Human operator is interfering with the system only through the graphical user interface. The error sources for this system are reduced to minimum.

  15. Test validation of nuclear and fossil fuel control operators

    International Nuclear Information System (INIS)

    Moffie, D.J.

    1976-01-01

    To establish job relatedness, one must go through a procedure of concurrent and predictive validation. For concurrent validity a group of employees is tested and the test scores are related to performance concurrently or during the same time period. For predictive validity, individuals are tested but the results of these tests are not used at the time of employment. The tests are sealed and scored at a later date, and then related to job performance. Job performance data include ratings by supervisors, actual job performance indices, turnover, absenteeism, progress in training, etc. The testing guidelines also stipulate that content and construct validity can be used

  16. Validation and test report

    DEFF Research Database (Denmark)

    Pedersen, Jens Meldgaard; Andersen, T. Bull

    2012-01-01

    . As a consequence of extensive movement artefacts seen during dynamic contractions, the following validation and test report consists of a report that investigates the physiological responses to a static contraction in a standing and a supine position. Eight subjects performed static contractions of the ankle...

  17. IP validation in remote microelectronics testing

    Science.gov (United States)

    Osseiran, Adam; Eshraghian, Kamran; Lachowicz, Stefan; Zhao, Xiaoli; Jeffery, Roger; Robins, Michael

    2004-03-01

    This paper presents the test and validation of FPGA based IP using the concept of remote testing. It demonstrates how a virtual tester environment based on a powerful, networked Integrated Circuit testing facility, aimed to complement the emerging Australian microelectronics based research and development, can be employed to perform the tasks beyond the standard IC test. IC testing in production consists in verifying the tested products and eliminating defective parts. Defects could have a number of different causes, including process defects, process migration and IP design and implementation errors. One of the challenges in semiconductor testing is that while current fault models are used to represent likely faults (stuck-at, delay, etc.) in a global context, they do not account for all possible defects. Research in this field keeps growing but the high cost of ATE is preventing a large community from accessing test and verification equipment to validate innovative IP designs. For these reasons a world class networked IC teletest facility has been established in Australia under the support of the Commonwealth government. The facility is based on a state-of-the-art semiconductor tester operating as a virtual centre spanning Australia and accessible internationally. Through a novel approach the teletest network provides virtual access to the tester on which the DUT has previously been placed. The tester software is then accessible as if the designer is sitting next to the tester. This paper presents the approach used to test and validate FPGA based IPs using this remote test approach.

  18. Construct Validity of the Nepalese School Leaving English Reading Test

    Science.gov (United States)

    Dawadi, Saraswati; Shrestha, Prithvi N.

    2018-01-01

    There has been a steady interest in investigating the validity of language tests in the last decades. Despite numerous studies on construct validity in language testing, there are not many studies examining the construct validity of a reading test. This paper reports on a study that explored the construct validity of the English reading test in…

  19. In-Situ Load System for Calibrating and Validating Aerodynamic Properties of Scaled Aircraft in Ground-Based Aerospace Testing Applications

    Science.gov (United States)

    Commo, Sean A. (Inventor); Lynn, Keith C. (Inventor); Landman, Drew (Inventor); Acheson, Michael J. (Inventor)

    2016-01-01

    An In-Situ Load System for calibrating and validating aerodynamic properties of scaled aircraft in ground-based aerospace testing applications includes an assembly having upper and lower components that are pivotably interconnected. A test weight can be connected to the lower component to apply a known force to a force balance. The orientation of the force balance can be varied, and the measured forces from the force balance can be compared to applied loads at various orientations to thereby develop calibration factors.

  20. High Power Alternator Test Unit (ATU) Electrical System Test

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2007-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.

  1. Development of Final Running Test System for Digital Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed.

  2. Development of Final Running Test System for Digital Systems

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok

    2016-01-01

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed

  3. Validating the Interpretations and Uses of Test Scores

    Science.gov (United States)

    Kane, Michael T.

    2013-01-01

    To validate an interpretation or use of test scores is to evaluate the plausibility of the claims based on the scores. An argument-based approach to validation suggests that the claims based on the test scores be outlined as an argument that specifies the inferences and supporting assumptions needed to get from test responses to score-based…

  4. Validity of selected cardiovascular field-based test among Malaysian ...

    African Journals Online (AJOL)

    Based on emerge obese problem among Malaysian, this research is formulated to validate published tests among healthy female adult. Selected test namely; 20 meter multi-stage shuttle run, 2.4km run test, 1 mile walk test and Harvard Step test were correlated with laboratory test (Bruce protocol) to find the criterion validity ...

  5. Development and Validation of a Food-Associated Olfactory Test (FAOT).

    Science.gov (United States)

    Denzer-Lippmann, Melanie Yvonne; Beauchamp, Jonathan; Freiherr, Jessica; Thuerauf, Norbert; Kornhuber, Johannes; Buettner, Andrea

    2017-01-01

    Olfactory tests are an important tool in human nutritional research for studying food preferences, yet comprehensive tests dedicated solely to food odors are currently lacking. Therefore, within this study, an innovative food-associated olfactory test (FAOT) system was developed. The FAOT comprises 16 odorant pens that contain representative food odors relating to different macronutrient classes. The test underwent a sensory validation based on identification rate, intensity, hedonic value, and food association scores. The accuracy of the test was further compared to the accuracy of the established Sniffin' Sticks identification test. The identification rates and intensities of this new FAOT were found to be comparable to the Sniffin' Sticks olfactory identification test. The odorant pens were also assessed chemo-analytically and were found to be chemically stable for at least 24 weeks. Overall, this new identification test for use in assessing olfaction in a food-associated context is valid both in terms of its use in sensory perception studies and its chemical stability. The FOAT is particularly suited to examinations of the sense of smell regarding food odors. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Wave Tank Testing and Model Validation of an Autonomous Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Bret Bosma

    2015-08-01

    Full Text Available A key component in bringing ocean wave energy converters from concept to commercialization is the building and testing of scaled prototypes to provide model validation. A one quarter scale prototype of an autonomous two body heaving point absorber was modeled, built, and tested for this work. Wave tank testing results are compared with two hydrodynamic and system models—implemented in both ANSYS AQWA and MATLAB/Simulink—and show model validation over certain regions of operation. This work will serve as a guide for future developers of wave energy converter devices, providing insight in taking their design from concept to prototype stage.

  7. Experimental validation of control strategies for a microgrid test facility including a storage system and renewable generation sets

    DEFF Research Database (Denmark)

    Baccino, Francesco; Marinelli, Mattia; Silvestro, Federico

    2012-01-01

    The paper is aimed at describing and validating some control strategies in the SYSLAB experimental test facility characterized by the presence of a low voltage network with a 15 kW-190 kWh Vanadium Redox Flow battery system and a 11 kW wind turbine. The generation set is connected to the local...... network and is fully controllable by the SCADA system. The control strategies, implemented on a local pc interfaced to the SCADA, are realized in Matlab-Simulink. The main purpose is to control the charge/discharge action of the storage system in order to present at the point of common coupling...... the desired power or energy profiles....

  8. Diversity and testing requirements of programmable automation systems

    International Nuclear Information System (INIS)

    Haapanen, P.; Maskuniitty, M.

    1993-04-01

    In the report programmable digital operation and safety automation systems for nuclear power plants are discussed. The programmable systems deviate by their properties and behaviour from the conventional non-programmable systems in such extent, that their verification and validation for safety critical applications requires new methods and practices. The safety assessment can not be based on conventional probabilistic methods due to the difficulties in the quantification of the reliability of the software and hardware. A safety critical programmable system shall include diverse redundant parts so that no residual program fault can not cause the failure of the intended function of the system. Although complete testing of a programmable system is impossible, different tests have a central role in the production and validation process of the system. Diversity is important also in confidence building measures for the implemented system. Independent analysis and testing of the system should use different methods and tools from those used in the production and validation process by the system vendor. Use of diversity and testing are concluded to be central issues in producing safe programmable system and in proving them to be safe enough. By combining functional and programming diversity in a suitable way one can produce a system that is safe enough without having a non-programmable back-up system. (48 refs., 10 figs., 2 tabs.)

  9. Validation of the Vanderbilt Holistic Face Processing Test

    OpenAIRE

    Wang, Chao-Chih; Ross, David A.; Gauthier, Isabel; Richler, Jennifer J.

    2016-01-01

    The Vanderbilt Holistic Face Processing Test (VHPT-F) is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014). In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the ...

  10. Validation of the Vanderbilt Holistic Face Processing Test.

    OpenAIRE

    Chao-Chih Wang; Chao-Chih Wang; David Andrew Ross; Isabel Gauthier; Jennifer Joanna Richler

    2016-01-01

    The Vanderbilt Holistic Face Processing Test (VHPT-F) is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014). In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the ...

  11. SP-100 nuclear assembly test: Test assembly functional requirements and system arrangement

    International Nuclear Information System (INIS)

    Fallas, T.T.; Gluck, R.; Motwani, K.; Clay, H.; O'Neill, G.

    1991-01-01

    This paper describes the functional requirements and the system that will be tested to validate the reactor, flight shield, and flight controller of the SP-100 Generic Flight System (GFS). The Nuclear Assembly Test (NAT) consists of the test article (SP-100 reactor with control devices and the flight shield) and its supporting systems. The NAT test assembly is being designed by GE. Westinghouse Hanford Company (WHC) is designing the test cell and vacuum vessel system that will contain the NAT test assembly (Renkey et al. 1989). Preliminary design reviews have been completed and the final design is under way

  12. Test Method Facet and the Construct Validity of Listening Comprehension Tests

    Directory of Open Access Journals (Sweden)

    Roya Khoii

    2010-05-01

    Full Text Available The assessment of listening abilities is one of the least understood, least developed and, yet, one of the most important areas of language testing and assessment. It is particularly important because of its potential wash-back effects on classroom practices. Given the fact that listening tests play a great role in assessing the language proficiency of students, they are expected to enjoy a high level of construct validity. The present study was dedicated to investigating the construct validity of three different test formats, namely, multiple-choice, gap filling on summary (also called listening summary cloze, and fill-in-the-blank, used to evaluate the listening comprehension of EFL learners. In order to achieve the purpose of the study, three passages with relatively similar readability levels were used for the construction of 9 listening tests, that is, each appeared in three formats. Following a counter-balanced design, the tests were administered to 91homogeneous EFL learners divided into three groups. The statistical analysis of the results revealed that the multiple-choice test enjoyed the highest level of construct validity. Moreover, a repeated measure one-way ANOVA demonstrated that the fill-in-the-blank task was the most difficult with the MC test as the easiest for the participants.

  13. Test of Gross Motor Development : Expert Validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-12-01

    Full Text Available The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motordevelopment. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by expertsand the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. Across-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionalsand 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls.Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated thatthe Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices ofconfirmatory factorial validity (χ2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tuckerand Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. ThePortuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  14. Test of Gross Motor Development: expert validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-01-01

    The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motor development. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by experts and the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. A cross-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionals and 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls. Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated that the Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices of confirmatory factorial validity (÷2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tucker and Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. The Portuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  15. FAST Model Calibration and Validation of the OC5-DeepCwind Floating Offshore Wind System Against Wave Tank Test Data

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Fabian F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Robertson, Amy N [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jonkman, Jason [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-06-03

    During the course of the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. This paper discusses several model calibration studies that were conducted to identify model adjustments that improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitch and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more-complex combined wind and wave validation cases.

  16. Design and validation of a general purpose robotic testing system for musculoskeletal applications.

    Science.gov (United States)

    Noble, Lawrence D; Colbrunn, Robb W; Lee, Dong-Gil; van den Bogert, Antonie J; Davis, Brian L

    2010-02-01

    Orthopaedic research on in vitro forces applied to bones, tendons, and ligaments during joint loading has been difficult to perform because of limitations with existing robotic simulators in applying full-physiological loading to the joint under investigation in real time. The objectives of the current work are as follows: (1) describe the design of a musculoskeletal simulator developed to support in vitro testing of cadaveric joint systems, (2) provide component and system-level validation results, and (3) demonstrate the simulator's usefulness for specific applications of the foot-ankle complex and knee. The musculoskeletal simulator allows researchers to simulate a variety of loading conditions on cadaver joints via motorized actuators that simulate muscle forces while simultaneously contacting the joint with an external load applied by a specialized robot. Multiple foot and knee studies have been completed at the Cleveland Clinic to demonstrate the simulator's capabilities. Using a variety of general-use components, experiments can be designed to test other musculoskeletal joints as well (e.g., hip, shoulder, facet joints of the spine). The accuracy of the tendon actuators to generate a target force profile during simulated walking was found to be highly variable and dependent on stance position. Repeatability (the ability of the system to generate the same tendon forces when the same experimental conditions are repeated) results showed that repeat forces were within the measurement accuracy of the system. It was determined that synchronization system accuracy was 6.7+/-2.0 ms and was based on timing measurements from the robot and tendon actuators. The positioning error of the robot ranged from 10 microm to 359 microm, depending on measurement condition (e.g., loaded or unloaded, quasistatic or dynamic motion, centralized movements or extremes of travel, maximum value, or root-mean-square, and x-, y- or z-axis motion). Algorithms and methods for controlling

  17. Ecological validity of the five digit test and the oral trails test.

    Science.gov (United States)

    Paiva, Gabrielle Chequer de Castro; Fialho, Mariana Braga; Costa, Danielle de Souza; Paula, Jonas Jardim de

    2016-01-01

    Tests evaluating the attentional-executive system are widely used in clinical practice. However, proximity of an objective cognitive test with real-world situations (ecological validity) is not frequently investigated. The present study evaluate the association between measures of the Five Digit Test (FDT) and the Oral Trails Test (OTT) with self-reported cognitive failures in everyday life as measured by the Cognitive Failures Questionnaire (CFQ). Brazilian adults from 18-to-65 years old voluntarily performed the FDT and OTT tests and reported the frequency of cognitive failures in their everyday life through the CFQ. After controlling for the age effect, the measures of controlled attentional processes were associated with cognitive failures, yet the cognitive flexibility of both FDT and OTT accounted for by the majority of variance in most aspects of the CFQ factors. The FDT and the OTT measures were predictive of real-world problems such as cognitive failures in everyday activities/situations.

  18. Recent trends on Software Verification and Validation Testing

    International Nuclear Information System (INIS)

    Kim, Hyungtae; Jeong, Choongheui

    2013-01-01

    Verification and Validation (V and V) include the analysis, evaluation, review, inspection, assessment, and testing of products. Especially testing is an important method to verify and validate software. Software V and V testing covers test planning to execution. IEEE Std. 1012 is a standard on the software V and V. Recently, IEEE Std. 1012-2012 was published. This standard is a major revision to IEEE Std. 1012-2004 which defines only software V and V. It expands the scope of the V and V processes to include system and hardware as well as software. This standard describes the scope of V and V testing according to integrity level. In addition, independent V and V requirement related to software V and V testing in IEEE 7-4.3.2-2010 have been revised. This paper provides a recent trend of software V and V testing by reviewing of IEEE Std. 1012-2012 and IEEE 7-4.3.2-2010. There are no major changes of software V and V testing activities and tasks in IEEE 1012-2012 compared with IEEE 1012-2004. But the positions on the responsibility to perform software V and V testing are changed. In addition IEEE 7-4.3.2-2010 newly describes the positions on responsibility to perform Software V and V Testing. However, the positions of these standards on the V and V testing are different. For integrity level 3 and 4, IEEE 1012-2012 basically requires that V and V organization shall conduct all of V and V testing tasks such as test plan, test design, test case, and test procedure except test execution. If V and V testing is conducted by not V and V but another organization, the results of that testing shall be analyzed by the V and V organization. For safety-related software, IEEE 7-4.3.2-2010 requires that test procedures and reports shall be independently verified by the alternate organization regardless of who writes the procedures and/or conducts the tests

  19. Model-Driven Test Generation of Distributed Systems

    Science.gov (United States)

    Easwaran, Arvind; Hall, Brendan; Schweiker, Kevin

    2012-01-01

    This report describes a novel test generation technique for distributed systems. Utilizing formal models and formal verification tools, spe cifically the Symbolic Analysis Laboratory (SAL) tool-suite from SRI, we present techniques to generate concurrent test vectors for distrib uted systems. These are initially explored within an informal test validation context and later extended to achieve full MC/DC coverage of the TTEthernet protocol operating within a system-centric context.

  20. Flight Testing an Iced Business Jet for Flight Simulation Model Validation

    Science.gov (United States)

    Ratvasky, Thomas P.; Barnhart, Billy P.; Lee, Sam; Cooper, Jon

    2007-01-01

    A flight test of a business jet aircraft with various ice accretions was performed to obtain data to validate flight simulation models developed through wind tunnel tests. Three types of ice accretions were tested: pre-activation roughness, runback shapes that form downstream of the thermal wing ice protection system, and a wing ice protection system failure shape. The high fidelity flight simulation models of this business jet aircraft were validated using a software tool called "Overdrive." Through comparisons of flight-extracted aerodynamic forces and moments to simulation-predicted forces and moments, the simulation models were successfully validated. Only minor adjustments in the simulation database were required to obtain adequate match, signifying the process used to develop the simulation models was successful. The simulation models were implemented in the NASA Ice Contamination Effects Flight Training Device (ICEFTD) to enable company pilots to evaluate flight characteristics of the simulation models. By and large, the pilots confirmed good similarities in the flight characteristics when compared to the real airplane. However, pilots noted pitch up tendencies at stall with the flaps extended that were not representative of the airplane and identified some differences in pilot forces. The elevator hinge moment model and implementation of the control forces on the ICEFTD were identified as a driver in the pitch ups and control force issues, and will be an area for future work.

  1. Virtualization of System of Systems Test and Evaluation

    Science.gov (United States)

    2012-06-04

    computers and is the primary enabler for virtualization. 2. Virtualization System Elements Parmalee, Peterson , Tillman, & Hatfield (1972) outlined the...The work of Abu-Taieh and El Sheikh, based on the work of Balci (1994, 1995), and Balci et al. ( 1996 ), seeks to organize types of tests and to...and testing. In A. Dasso & A. Funes (Eds.), Verification, validation, and testing in software engineering (pp. 155–184). Hershey , PA: Idea Group

  2. Introduction to Large-sized Test Facility for validating Containment Integrity under Severe Accidents

    International Nuclear Information System (INIS)

    Na, Young Su; Hong, Seongwan; Hong, Seongho; Min, Beongtae

    2014-01-01

    An overall assessment of containment integrity can be conducted properly by examining the hydrogen behavior in the containment building. Under severe accidents, an amount of hydrogen gases can be generated by metal oxidation and corium-concrete interaction. Hydrogen behavior in the containment building strongly depends on complicated thermal hydraulic conditions with mixed gases and steam. The performance of a PAR can be directly affected by the thermal hydraulic conditions, steam contents, gas mixture behavior and aerosol characteristics, as well as the operation of other engineering safety systems such as a spray. The models in computer codes for a severe accident assessment can be validated based on the experiment results in a large-sized test facility. The Korea Atomic Energy Research Institute (KAERI) is now preparing a large-sized test facility to examine in detail the safety issues related with hydrogen including the performance of safety devices such as a PAR in various severe accident situations. This paper introduces the KAERI test facility for validating the containment integrity under severe accidents. To validate the containment integrity, a large-sized test facility is necessary for simulating complicated phenomena induced by an amount of steam and gases, especially hydrogen released into the containment building under severe accidents. A pressure vessel 9.5 m in height and 3.4 m in diameter was designed at the KAERI test facility for the validating containment integrity, which was based on the THAI test facility with the experimental safety and the reliable measurement systems certified for a long time. This large-sized pressure vessel operated in steam and iodine as a corrosive agent was made by stainless steel 316L because of corrosion resistance for a long operating time, and a vessel was installed in at KAERI in March 2014. In the future, the control systems for temperature and pressure in a vessel will be constructed, and the measurement system

  3. Development and validation of a theoretical test in basic laparoscopy

    DEFF Research Database (Denmark)

    Strandbygaard, Jeanett; Maagaard, Mathilde; Larsen, Christian Rifbjerg

    2013-01-01

    for first-year residents in obstetrics and gynecology. This study therefore aimed to develop and validate a framework for a theoretical knowledge test, a multiple-choice test, in basic theory related to laparoscopy. METHODS: The content of the multiple-choice test was determined by conducting informal...... conversational interviews with experts in laparoscopy. The subsequent relevance of the test questions was evaluated using the Delphi method involving regional chief physicians. Construct validity was tested by comparing test results from three groups with expected different clinical competence and knowledge.......001). Internal consistency (Cronbach's alpha) was 0.82. There was no evidence of differential item functioning between the three groups tested. CONCLUSIONS: A newly developed knowledge test in basic laparoscopy proved to have content and construct validity. The formula for the development and validation...

  4. Dynamic testing in schizophrenia: does training change the construct validity of a test?

    Science.gov (United States)

    Wiedl, Karl H; Schöttke, Henning; Green, Michael F; Nuechterlein, Keith H

    2004-01-01

    Dynamic testing typically involves specific interventions for a test to assess the extent to which test performance can be modified, beyond level of baseline (static) performance. This study used a dynamic version of the Wisconsin Card Sorting Test (WCST) that is based on cognitive remediation techniques within a test-training-test procedure. From results of previous studies with schizophrenia patients, we concluded that the dynamic and static versions of the WCST should have different construct validity. This hypothesis was tested by examining the patterns of correlations with measures of executive functioning, secondary verbal memory, and verbal intelligence. Results demonstrated a specific construct validity of WCST dynamic (i.e., posttest) scores as an index of problem solving (Tower of Hanoi) and secondary verbal memory and learning (Auditory Verbal Learning Test), whereas the impact of general verbal capacity and selective attention (Verbal IQ, Stroop Test) was reduced. It is concluded that the construct validity of the test changes with dynamic administration and that this difference helps to explain why the dynamic version of the WCST predicts functional outcome better than the static version.

  5. Is outdoor use of the six-minute walk test with a global positioning system in stroke patients' own neighbourhoods reproducible and valid?

    OpenAIRE

    Wevers, L.E.; Kwakkel, G.; Port, van de, I.G.

    2011-01-01

    Objective: To examine the reproducibility, responsiveness and concurrent validity of the six-minute walk test (6MWT) when tested outdoors in patients' own neighbourhoods using a global positioning system (GPS) or a measuring wheel. Methods: A total of 27 chronic stroke patients, discharged to their own homes, were tested twice, within 5 consecutive days. The 6MWT was conducted using a GPS and an measuring wheel simultaneously to determine walking distance. Reproducibility was determined as te...

  6. Methodology for testing and validating knowledge bases

    Science.gov (United States)

    Krishnamurthy, C.; Padalkar, S.; Sztipanovits, J.; Purves, B. R.

    1987-01-01

    A test and validation toolset developed for artificial intelligence programs is described. The basic premises of this method are: (1) knowledge bases have a strongly declarative character and represent mostly structural information about different domains, (2) the conditions for integrity, consistency, and correctness can be transformed into structural properties of knowledge bases, and (3) structural information and structural properties can be uniformly represented by graphs and checked by graph algorithms. The interactive test and validation environment have been implemented on a SUN workstation.

  7. DTU PMU Laboratory Development - Testing and Validation

    OpenAIRE

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.; Nielsen, Arne Hejde; Østergaard, Jacob

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to foll...

  8. Validation of the process control system of an automated large scale manufacturing plant.

    Science.gov (United States)

    Neuhaus, H; Kremers, H; Karrer, T; Traut, R H

    1998-02-01

    The validation procedure for the process control system of a plant for the large scale production of human albumin from plasma fractions is described. A validation master plan is developed, defining the system and elements to be validated, the interfaces with other systems with the validation limits, a general validation concept and supporting documentation. Based on this master plan, the validation protocols are developed. For the validation, the system is subdivided into a field level, which is the equipment part, and an automation level. The automation level is further subdivided into sections according to the different software modules. Based on a risk categorization of the modules, the qualification activities are defined. The test scripts for the different qualification levels (installation, operational and performance qualification) are developed according to a previously performed risk analysis.

  9. Development of an expert system for signal validation: Topical report

    International Nuclear Information System (INIS)

    Qualls, A.L.; Uhrig, R.E.; Upadhyaya, B.R.

    1988-07-01

    A signal validation and sensor information expert system is developed and applied to nuclear power plant subsystems. The expert system interactively provides the user with a list of sensors used to monitor a subsystem of a power plant and answers the user's questions about the characteristics of those sensors. The expert system performs an evaluation of the present output characteristics of an instrument channel. The evaluation is fully automated and is designed to mimic an operator's approach to signal validation. The evaluation is designed to detect three types of possible sensor anomalies: (1) incorrect average output, (2) improper noise level,and (3) incorrect response to a system perturbation. There are two tests used to detect each possible anomalous condition. One test is a comparison of the specified sensor characteristic against the same characteristic of its redundant sensors. The second test is a prediction of the sensor's expected behavior and comparison with its observed behavior. The evaluation was tested using operational data from twelve sensors used to monitor level, pressure, primary and secondary coolant flow rates, and hot and cold leg temperatures of a steam generator in a commercial nuclear power plant. The results of the testing demonstrated successfully that the evaluation detected the three possible anomalies, and was able to handle conflicting information using the comparison among redundant sensors and the system specific test used to detect the anomalies

  10. Expert system verification and validation for nuclear power industry applications

    International Nuclear Information System (INIS)

    Naser, J.A.

    1990-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of times required to perform certain functions, the prevention of equipment failures through predictive diagnostics, and the retention of human expertise in performing specialized functions. The increased use of expert systems brings with it concerns about their reliability. Difficulties arising from software problems can affect plant safety, reliability, and availability. A joint project between EPRI and the US Nuclear Regulatory Commission is being initiated to develop a methodology for verification and validation of expert systems for nuclear power applications. This methodology will be tested on existing and developing expert systems. This effort will explore the applicability of conventional verification and validation methodologies to expert systems. The major area of concern will be certification of the knowledge base. This is expected to require new types of verification and validation techniques. A methodology for developing validation scenarios will also be studied

  11. Flight test techniques for validating simulated nuclear electromagnetic pulse aircraft responses

    Science.gov (United States)

    Winebarger, R. M.; Neely, W. R., Jr.

    1984-01-01

    An attempt has been made to determine the effects of nuclear EM pulses (NEMPs) on aircraft systems, using a highly instrumented NASA F-106B to document the simulated NEMP environment at the Kirtland Air Force Base's Vertically Polarized Dipole test facility. Several test positions were selected so that aircraft orientation relative to the test facility would be the same in flight as when on the stationary dielectric stand, in order to validate the dielectric stand's use in flight configuration simulations. Attention is given to the flight test portions of the documentation program.

  12. Validating a Spanish Developmental Spelling Test.

    Science.gov (United States)

    Ferroli, Lou; Krajenta, Marilyn

    The creation and validation of a Spanish version of an English developmental spelling test (DST) is described. An introductory section reviews related literature on the rationale for and construction of DSTs, spelling development in the early grades, and Spanish-English bilingual education. Differences between the English and Spanish test versions…

  13. System of tactical assessment in Soccer (FUT-SAT: Development and preliminary validation

    Directory of Open Access Journals (Sweden)

    I.T. Costa

    2011-01-01

    Full Text Available The purpose of this paper was to report the development and preliminary validation of tactical assessment system in Soccer and highlight its advantages. The validation process followed five perspectives of the concept of validity that consider the value of heuristic methods and the importance of the description of behavior performed in playing situations. Thus, the process of validation was focused on four points: i acceptability and reasonableness of the test perceived by players; ii analysis of content of assessment tool through a panel of experts; iii potential of the assessment tool to discriminate the quality of the performance of players; iv observation reliability. The results displayed values higher than 0.63 for correlation between the evaluations of coaches and the system. It shows the potential of this system to distinguish the performances of players based on the evaluations of coaches. The players who performed the field test agreed with its physical demands and spatial and normative configurations. All experts endorsed the categories and variables of this system. The reliabilities showed values higher than 0.79 for intra and inter-observers. Therefore, it is possible to conclude that the system is valid and reliable for the assessment of the tactical behavior of soccer players.

  14. Validity of the Jump-and-Reach Test in Subelite Adolescent Handball Players.

    Science.gov (United States)

    Muehlbauer, Thomas; Pabst, Jan; Granacher, Urs; Büsch, Dirk

    2017-05-01

    Muehlbauer, T, Pabst, J, Granacher, U, and Büsch, D. Validity of the jump-and-reach test in subelite adolescent handball players. J Strength Cond Res 31(5): 1282-1289, 2017-The primary purpose of this study was to examine concurrent validity of the jump-and-reach (JaR) test using the Vertec system and a criterion device (i.e., Optojump system). In separate subanalyses, we investigated the influence of gym floor condition and athletes' sex on the validity of vertical jump height. Four hundred forty subelite adolescent female (n = 222, mean age: 14 ± 1 year, age range: 13-15 years) and male (n = 218, mean age: 15 ± 1 year, age range: 14-16 years) handball players performed the JaR test in gyms with region or point elastic floors. Maximal vertical jump height was simultaneously assessed using the Vertec and the Optojump systems. In general, significantly higher jump heights were obtained for the Vertec compared with the Optojump system (11.2 cm, Δ31%, Cohen's d = 2.58). The subanalyses revealed significantly larger jump heights for the Vertec compared with the Optojump system irrespective of gym floor condition and players' sex. The association between Optojump- and Vertec-derived vertical jump heights amounted to rP = 0.84, with a coefficient of determination (R) of 0.71. The subanalyses indicated significantly larger correlations in males (rP = 0.75, R = 0.56) than in females (rP = 0.63, R = 0.40). Yet, correlations were not significantly different between region (rP = 0.83, R = 0.69) as opposed to point elastic floor (rP = 0.87, R = 0.76). Our findings indicate that the 2 apparatuses cannot be used interchangeably. Consequently, gym floor and sex-specific regression equations were provided to estimate true (Optojump system) vertical jump height from Vertec-derived data.

  15. Testing the Predictive Validity of the Hendrich II Fall Risk Model.

    Science.gov (United States)

    Jung, Hyesil; Park, Hyeoun-Ae

    2018-03-01

    Cumulative data on patient fall risk have been compiled in electronic medical records systems, and it is possible to test the validity of fall-risk assessment tools using these data between the times of admission and occurrence of a fall. The Hendrich II Fall Risk Model scores assessed during three time points of hospital stays were extracted and used for testing the predictive validity: (a) upon admission, (b) when the maximum fall-risk score from admission to falling or discharge, and (c) immediately before falling or discharge. Predictive validity was examined using seven predictive indicators. In addition, logistic regression analysis was used to identify factors that significantly affect the occurrence of a fall. Among the different time points, the maximum fall-risk score assessed between admission and falling or discharge showed the best predictive performance. Confusion or disorientation and having a poor ability to rise from a sitting position were significant risk factors for a fall.

  16. Utility, reliability, sensitivity and validity of an online test system designed to monitor changes in cognitive function in clinical trials.

    Science.gov (United States)

    Wesnes, Keith A; Brooker, Helen; Ballard, Clive; McCambridge, Laura; Stenton, Robert; Corbett, Anne

    2017-12-01

    The advent of long-term remotely conducted clinical trials requires assessments which can be administered online. This paper considers the utility, reliability, sensitivity and validity of an internet-based system for measuring changes in cognitive function which is being used in one such trial. The Platform for Research Online to investigate Genetics and Cognition in Ageing is a 10-year longitudinal and entirely remote study launched in November 2015. The CogTrack TM System is being used to monitor changes in important aspects of cognitive function using tests of attention, information processing and episodic memory. On study entry, the participants performed CogTrack TM up to three times over seven days, and these data are evaluated in this paper. During the first six months of the study, 14 531 individuals aged 50 to 94 years enrolled and performed the CogTrack TM System, 8627 of whom completed three test sessions. On the first administration, 99.4% of the study tasks were successfully completed. Repeated testing showed training/familiarisation effects on four of the ten measures which had largely stabilised by the third test session. The factor structure of the various measures was found to be robust. Evaluation of the influence of age identified clinically relevant declines over the age range of the population on one or more measures from all tasks. The results of these analyses identify CogTrack TM to be a practical and valid method to reliably, sensitively, remotely and repeatedly collect cognitive data from large samples of individuals aged 50 and over. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  17. FAST Model Calibration and Validation of the OC5- DeepCwind Floating Offshore Wind System Against Wave Tank Test Data: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Fabian F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Robertson, Amy N [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jonkman, Jason [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-09

    During the course of the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. This paper discusses several model calibration studies that were conducted to identify model adjustments that improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitch and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more-complex combined wind and wave validation cases.

  18. Validation Ice Crystal Icing Engine Test in the Propulsion Systems Laboratory at NASA Glenn Research Center

    Science.gov (United States)

    Oliver, Michael J.

    2014-01-01

    The Propulsion Systems Laboratory (PSL) is an existing altitude simulation jet engine test facility located at NASA Glenn Research Center in Cleveland, OH. It was modified in 2012 with the integration of an ice crystal cloud generation system. This paper documents the inaugural ice crystal cloud test in PSL--the first ever full scale, high altitude ice crystal cloud turbofan engine test to be conducted in a ground based facility. The test article was a Lycoming ALF502-R5 high bypass turbofan engine, serial number LF01. The objectives of the test were to validate the PSL ice crystal cloud calibration and engine testing methodologies by demonstrating the capability to calibrate and duplicate known flight test events that occurred on the same LF01 engine and to generate engine data to support fundamental and computational research to investigate and better understand the physics of ice crystal icing in a turbofan engine environment while duplicating known revenue service events and conducting test points while varying facility and engine parameters. During PSL calibration testing it was discovered than heated probes installed through tunnel sidewalls experienced ice buildup aft of their location due to ice crystals impinging upon them, melting and running back. Filtered city water was used in the cloud generation nozzle system to provide ice crystal nucleation sites. This resulted in mineralization forming on flow path hardware that led to a chronic degradation of performance during the month long test. Lacking internal flow path cameras, the response of thermocouples along the flow path was interpreted as ice building up. Using this interpretation, a strong correlation between total water content (TWC) and a weaker correlation between median volumetric diameter (MVD) of the ice crystal cloud and the rate of ice buildup along the instrumented flow path was identified. For this test article the engine anti-ice system was required to be turned on before ice crystal

  19. Test-retest reliability and predictive validity of the Implicit Association Test in children.

    Science.gov (United States)

    Rae, James R; Olson, Kristina R

    2018-02-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many factors simultaneously (lag-time between testing administrations, domain, etc.), it is difficult to discern what factors may explain variability in existing test-retest reliability and predictive validity estimates. Across five studies (total N = 519; ages 6- to 11-years-old), we manipulated two factors that have varied in previous developmental research-lag-time and domain. An internal meta-analysis of these studies revealed that, across three different methods of analyzing the data, mean test-retest (rs of .48, .38, and .34) and predictive validity (rs of .46, .20, and .10) effect sizes were significantly greater than zero. While lag-time did not moderate the magnitude of test-retest coefficients, whether we observed domain differences in test-retest reliability and predictive validity estimates was contingent on other factors, such as how we scored the IAT or whether we included estimates from a unique sample (i.e., a sample containing gender typical and gender diverse children). Recommendations are made for developmental researchers that utilize the IAT in their research. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  20. Educational testing validity and reliability in pharmacy and medical education literature.

    Science.gov (United States)

    Hoover, Matthew J; Jung, Rose; Jacobs, David M; Peeters, Michael J

    2013-12-16

    To evaluate and compare the reliability and validity of educational testing reported in pharmacy education journals to medical education literature. Descriptions of validity evidence sources (content, construct, criterion, and reliability) were extracted from articles that reported educational testing of learners' knowledge, skills, and/or abilities. Using educational testing, the findings of 108 pharmacy education articles were compared to the findings of 198 medical education articles. For pharmacy educational testing, 14 articles (13%) reported more than 1 validity evidence source while 83 articles (77%) reported 1 validity evidence source and 11 articles (10%) did not have evidence. Among validity evidence sources, content validity was reported most frequently. Compared with pharmacy education literature, more medical education articles reported both validity and reliability (59%; particles in pharmacy education compared to medical education, validity, and reliability reporting were limited in the pharmacy education literature.

  1. Design and Experimental Validation of Hydraulic Yaw System for Multi MW Wind Turbine

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    market. A hydraulic yaw system is such a new technology, and so a mathematical model of the full scale system and test rig system is derived and compared to measurements from the system. This is done in order to have a validated model, which wind turbine manufacturers may use for test in their simulation......To comply with the increasing demands for life time and reliability of wind turbines as these grow in size, new measures needs to be taken in the design of wind turbines and components hereof. One critical point is the initial testing of the components and systems before they are implemented...... in an actual turbine. Full scale hardware testing is both extremely expensive and time consuming, and so the wind turbine industry moves more towards simulations when testing. In order to meet these demands it is necessary with valid models of systems in order to introduce new technologies to the wind turbine...

  2. Software test and validation of wireless sensor nodes used in nuclear power plant

    International Nuclear Information System (INIS)

    Deng Changjian; Chen Dongyi; Zhang Heng

    2015-01-01

    The software test and validation of wireless sensor nodes is one of the key approaches to improve or guarantee the reliability of wireless network application in nuclear power plants (NPPs). At first, to validate the software test, some concepts are defined quantitatively, for example the robustness of software, the reliability of software, and the security of software. Then the development tools and simulators of discrete event drive operating system are compared, in order to present robustness, reliability and security of software test approach based on input-output function. Some simple preliminary test results are given to show that different development software can obtain almost same measurement and communication results although the software of special application may be different than normal application. (author)

  3. Traffic modelling validation of advanced driver assistance systems

    NARCIS (Netherlands)

    Tongeren, R. van; Gietelink, O.J.; Schutter, B. de; Verhaegen, M.

    2007-01-01

    This paper presents a microscopic traffic model for the validation of advanced driver assistance systems. This model describes single-lane traffic and is calibrated with data from a field operational test. To illustrate the use of the model, a Monte Carlo simulation of single-lane traffic scenarios

  4. Experimental validation of a new heterogeneous mechanical test design

    Science.gov (United States)

    Aquino, J.; Campos, A. Andrade; Souto, N.; Thuillier, S.

    2018-05-01

    Standard material parameters identification strategies generally use an extensive number of classical tests for collecting the required experimental data. However, a great effort has been made recently by the scientific and industrial communities to support this experimental database on heterogeneous tests. These tests can provide richer information on the material behavior allowing the identification of a more complete set of material parameters. This is a result of the recent development of full-field measurements techniques, like digital image correlation (DIC), that can capture the heterogeneous deformation fields on the specimen surface during the test. Recently, new specimen geometries were designed to enhance the richness of the strain field and capture supplementary strain states. The butterfly specimen is an example of these new geometries, designed through a numerical optimization procedure where an indicator capable of evaluating the heterogeneity and the richness of strain information. However, no experimental validation was yet performed. The aim of this work is to experimentally validate the heterogeneous butterfly mechanical test in the parameter identification framework. For this aim, DIC technique and a Finite Element Model Up-date inverse strategy are used together for the parameter identification of a DC04 steel, as well as the calculation of the indicator. The experimental tests are carried out in a universal testing machine with the ARAMIS measuring system to provide the strain states on the specimen surface. The identification strategy is accomplished with the data obtained from the experimental tests and the results are compared to a reference numerical solution.

  5. Neutron flux control systems validation

    International Nuclear Information System (INIS)

    Hascik, R.

    2003-01-01

    In nuclear installations main requirement is to obtain corresponding nuclear safety in all operation conditions. From the nuclear safety point of view is commissioning and start-up after reactor refuelling appropriate period for safety systems verification. In this paper, methodology, performance and results of neutron flux measurements systems validation is presented. Standard neutron flux measuring chains incorporated into the reactor protection and control system are used. Standard neutron flux measuring chain contains detector, preamplifier, wiring to data acquisition unit, data acquisition unit, wiring to display at control room and display at control room. During reactor outage only data acquisition unit and wiring and displaying at reactor control room is verified. It is impossible to verify detector, preamplifier and wiring to data acquisition recording unit during reactor refuelling according to low power. Adjustment and accurate functionality of these chains is confirmed by start-up rate (SUR) measurement during start-up tests after refuelling of the reactors. This measurement has direct impact to nuclear safety and increase operational nuclear safety level. Briefly description of each measuring system is given. Results are illustrated on measurements performed at Bohunice NPP during reactor start-up tests. Main failures and their elimination are described (Authors)

  6. DESIGN AND VALIDATION OF AN INTERORGANIZATIONAL INFORMATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Kamel Rouibah

    2006-01-01

    Full Text Available This paper presents an interorganizational information system that aims to structure collaboration of engineering activities as well as data sharing across company borders. The paper also describes the approach underlying the system, validates it by designing a system prototype, and tests the system using questionnaire and in-depth interviews in order to further knowledge about the subject. The main results from the test show: collaboration engineering is potentially important for senior managers; end-users were specifically attracted more by the concept rather by its implementation; engineering change management is a complex process; and the support of strategic level is a critical success factor. In addition, the paper describes other factors that emerged during the ongoing project and inhibit success of the system.

  7. Pre-crash system validation with PRESCAN and VEHIL

    NARCIS (Netherlands)

    Gietelink, O.J.; Verburg, D.J.; Labibes, K.; Oostendorp, A.F.

    2004-01-01

    This paper presents the tools for design and validation of Pre-Crash Systems: the software tool PRE-crash SCenario ANalyzer (PRESCAN) and the VEhicle-Hardware-In-the-Loop (VEHIL) facility. PRESCAN allows to investigate a pre-crash scenario in simulation. This scenario can then be compared with tests

  8. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  9. Reliability, Validity, and Minimal Detectable Change of Balance Evaluation Systems Test and Its Short Versions in Older Cancer Survivors: A Pilot Study.

    Science.gov (United States)

    Huang, Min H; Miller, Kara; Smith, Kristin; Fredrickson, Kayle; Shilling, Tracy

    2016-01-01

    Cancer is primarily a disease of older adults. About 77% of all cancers are diagnosed in persons aged 55 years and older. Cancer and its treatment can cause diverse sequelae impacting body systems underlying balance control. No study has examined the psychometric properties of balance assessment tools in older cancer survivors, presenting a significant challenge in the selection of outcome measures for clinicians treating this fast-growing population. This study aimed to determine the reliability, validity, and minimal detectable change (MDC) of the Balance Evaluation System Test (BESTest), Mini-Balance Evaluation Systems Test (Mini-BESTest), and Brief-Balance Evaluation Systems Test (Brief-BESTest) in community-dwelling older cancer survivors. This study was a cross-sectional design. Twenty breast and 8 prostate cancer survivors participated [age (SD) = 68.4 (8.13) years]. The BESTest and Activity-specific Balance Confidence (ABC) Scale were administered during the first session. Scores of Mini-BESTest and Brief-BESTest were extracted on the basis of the scores of BESTest. The BESTest was repeated within 1 to 2 weeks by the same rater to determine the test-retest reliability. For the analysis of the inter-rater reliability, 21 participants were randomly selected to be evaluated by 2 raters. A primary rater administered the test. The 2 raters independently and concurrently scored the performance of the participants. Each rater recorded the ratings separately on the scoring sheet. No discussion among the raters was allowed throughout the testing. Intraclass correlation coefficients (ICCs), standard error of measurement, minimal detectable change (MDC), and Bland-Altman plots were calculated. Concurrent validity of these balance tests with the ABC Scale was examined using the Spearman correlation. The BESTest, Mini-BESTest, and Brief-BESTest had high test-retest (ICC = 0.90-0.94) and interrater reliability (ICC = 0.86-0.96), small standard error of measurement (0

  10. Safe and secure South Africa. Vehicle landmine protection validation testing

    CSIR Research Space (South Africa)

    Reinecke, JD

    2008-11-01

    Full Text Available The objective of this paper is to provide an overview of vehicle landmine protection validation testing in South Africa. A short history of validation test standards is given, followed by a summary of current open test standards in general use...

  11. Automated real-time testing (ARTT) for embedded control systems (ECS)

    International Nuclear Information System (INIS)

    Hawkins, J; Howard, R; Nguyen, H.

    2001-01-01

    Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test runs and test cases. To measure the PSS system's test coverage three levels of system requirements were mapped to their respective unit level of test using a specially constructed validation matrix that was designed to handle over 150 test cases and requirements. All of the above work led to the development of an Automated Real-Time Test System (ARTTS) that is capable of performing complete black box testing in real-time for Embedded PLC Based Control Systems. Also note, that the PSS system under test and mentioned in this paper is located at the Advance Photon Source (APS) at Argonne National Laboratory Basic Energy Science Facility in Argonne, Illinois

  12. Certification Testing as an Illustration of Argument-Based Validation

    Science.gov (United States)

    Kane, Michael

    2004-01-01

    The theories of validity developed over the past 60 years are quite sophisticated, but the methodology of validity is not generally very effective. The validity evidence for major testing programs is typically much weaker than the evidence for more technical characteristics such as reliability. In addition, most validation efforts have a strong…

  13. Summary: Experimental validation of real-time fault-tolerant systems

    Science.gov (United States)

    Iyer, R. K.; Choi, G. S.

    1992-01-01

    Testing and validation of real-time systems is always difficult to perform since neither the error generation process nor the fault propagation problem is easy to comprehend. There is no better substitute to results based on actual measurements and experimentation. Such results are essential for developing a rational basis for evaluation and validation of real-time systems. However, with physical experimentation, controllability and observability are limited to external instrumentation that can be hooked-up to the system under test. And this process is quite a difficult, if not impossible, task for a complex system. Also, to set up such experiments for measurements, physical hardware must exist. On the other hand, a simulation approach allows flexibility that is unequaled by any other existing method for system evaluation. A simulation methodology for system evaluation was successfully developed and implemented and the environment was demonstrated using existing real-time avionic systems. The research was oriented toward evaluating the impact of permanent and transient faults in aircraft control computers. Results were obtained for the Bendix BDX 930 system and Hamilton Standard EEC131 jet engine controller. The studies showed that simulated fault injection is valuable, in the design stage, to evaluate the susceptibility of computing sytems to different types of failures.

  14. Integration and validation testing for PhEDEx, DBS and DAS with the PhEDEx LifeCycle agent

    International Nuclear Information System (INIS)

    Boeser, C; Chwalek, T; Giffels, M; Kuznetsov, V; Wildish, T

    2014-01-01

    The ever-increasing amount of data handled by the CMS dataflow and workflow management tools poses new challenges for cross-validation among different systems within CMS experiment at LHC. To approach this problem we developed an integration test suite based on the LifeCycle agent, a tool originally conceived for stress-testing new releases of PhEDEx, the CMS data-placement tool. The LifeCycle agent provides a framework for customising the test workflow in arbitrary ways, and can scale to levels of activity well beyond those seen in normal running. This means we can run realistic performance tests at scales not likely to be seen by the experiment for some years, or with custom topologies to examine particular situations that may cause concern some time in the future. The LifeCycle agent has recently been enhanced to become a general purpose integration and validation testing tool for major CMS services. It allows cross-system integration tests of all three components to be performed in controlled environments, without interfering with production services. In this paper we discuss the design and implementation of the LifeCycle agent. We describe how it is used for small-scale debugging and validation tests, and how we extend that to large-scale tests of whole groups of sub-systems. We show how the LifeCycle agent can emulate the action of operators, physicists, or software agents external to the system under test, and how it can be scaled to large and complex systems.

  15. Integration and validation testing for PhEDEx, DBS and DAS with the PhEDEx LifeCycle agent

    Science.gov (United States)

    Boeser, C.; Chwalek, T.; Giffels, M.; Kuznetsov, V.; Wildish, T.

    2014-06-01

    The ever-increasing amount of data handled by the CMS dataflow and workflow management tools poses new challenges for cross-validation among different systems within CMS experiment at LHC. To approach this problem we developed an integration test suite based on the LifeCycle agent, a tool originally conceived for stress-testing new releases of PhEDEx, the CMS data-placement tool. The LifeCycle agent provides a framework for customising the test workflow in arbitrary ways, and can scale to levels of activity well beyond those seen in normal running. This means we can run realistic performance tests at scales not likely to be seen by the experiment for some years, or with custom topologies to examine particular situations that may cause concern some time in the future. The LifeCycle agent has recently been enhanced to become a general purpose integration and validation testing tool for major CMS services. It allows cross-system integration tests of all three components to be performed in controlled environments, without interfering with production services. In this paper we discuss the design and implementation of the LifeCycle agent. We describe how it is used for small-scale debugging and validation tests, and how we extend that to large-scale tests of whole groups of sub-systems. We show how the LifeCycle agent can emulate the action of operators, physicists, or software agents external to the system under test, and how it can be scaled to large and complex systems.

  16. Development and Validation of a Theoretical Test in Endosonography for Pulmonary Diseases

    DEFF Research Database (Denmark)

    Savran, Mona M; Clementsen, Paul Frost; Annema, Jouke T

    2014-01-01

    evidence for this test. METHODS: Initially, 78 questions were constructed after informal conversational interviews with 4 international experts in endosonography. The clarity and content validity of the questions were tested using a Delphi-like approach. Construct validity was explored by administering......BACKGROUND: Theoretical testing provides the necessary foundation to perform technical skills. Additionally, testing improves the retention of knowledge. OBJECTIVES: The aims of this study were to develop a multiple-choice test in endosonography for pulmonary diseases and to gather validity...... consistently than the novices (p = 0.037) and the intermediates (p Validity evidence was gathered, and the test demonstrated content and construct validity....

  17. Safety testing for LHC access system

    CERN Document Server

    Valentini, F; Ninin, P; Scibile, S

    2008-01-01

    In the domain of Safety Real-Time Systems the problem of testing represents always a big effort in terms of time, costs and efficiency to guarantee an adequate coverage degree. Exhaustive tests may, in fact, not be practicable for large and distributed systems. This paper describes the testing process followed during the validation of the CERN's LHC Access System [1], responsible for monitoring and preventing physical risks for the personnel accessing the underground areas. In the paper we also present a novel strategy for the testing problem, intended to drastically reduce the time for the test patterns generation and execution. In particular, we propose a methodology for blackbox testing that relies on the application of Model Checking techniques. Model Checking is a formal method from computer science, commonly adopted to prove correctness of system’s models through an automatic system’s state space exploration against some property formulas.

  18. Chandra X-ray Center Science Data Systems Regression Testing of CIAO

    Science.gov (United States)

    Lee, N. P.; Karovska, M.; Galle, E. C.; Bonaventura, N. R.

    2011-07-01

    The Chandra Interactive Analysis of Observations (CIAO) is a software system developed for the analysis of Chandra X-ray Observatory observations. An important component of a successful CIAO release is the repeated testing of the tools across various platforms to ensure consistent and scientifically valid results. We describe the procedures of the scientific regression testing of CIAO and the enhancements made to the testing system to increase the efficiency of run time and result validation.

  19. Coverage of the Test of Memory Malingering, Victoria Symptom Validity Test, and Word Memory Test on the Internet: is test security threatened?

    Science.gov (United States)

    Bauer, Lyndsey; McCaffrey, Robert J

    2006-01-01

    In forensic neuropsychological settings, maintaining test security has become critically important, especially in regard to symptom validity tests (SVTs). Coaching, which can entail providing patients or litigants with information about the cognitive sequelae of head injury, or teaching them test-taking strategies to avoid detection of symptom dissimulation has been examined experimentally in many research studies. Emerging evidence supports that coaching strategies affect psychological and neuropsychological test performance to differing degrees depending on the coaching paradigm and the tests administered. The present study sought to examine Internet coverage of SVTs because it is potentially another source of coaching, or information that is readily available. Google searches were performed on the Test of Memory Malingering, the Victoria Symptom Validity Test, and the Word Memory Test. Results indicated that there is a variable amount of information available about each test that could threaten test security and validity should inappropriately interested parties find it. Steps that could be taken to improve this situation and limitations to this exploration are discussed.

  20. TCV software test and validation tools and technique. [Terminal Configured Vehicle program for commercial transport aircraft operation

    Science.gov (United States)

    Straeter, T. A.; Williams, J. R.

    1976-01-01

    The paper describes techniques for testing and validating software for the TCV (Terminal Configured Vehicle) program which is intended to solve problems associated with operating a commercial transport aircraft in the terminal area. The TCV research test bed is a Boeing 737 specially configured with digital computer systems to carry out automatic navigation, guidance, flight controls, and electronic displays research. The techniques developed for time and cost reduction include automatic documentation aids, an automatic software configuration, and an all software generation and validation system.

  1. Application of the Performance Validation Tool for the Evaluation of NSSS Control System Performance

    International Nuclear Information System (INIS)

    Sohn, Suk-whun

    2011-01-01

    When a control system is supplied to nuclear power plant (NPP) under construction, static tests and dynamic tests are typically performed for evaluating its performance. The dynamic test is not realistic for validating the performance of the replaced hardware in operating NPPs because of potential risks and economic burden. We have, therefore, developed a performance validation tool which can evaluate the dynamic performances of the control system without undertaking real plant tests. The window-based nuclear plant performance analyzer (Win-NPA) is used as a virtual NPP in the developed tool and provides appropriate control loads to the target control system via hardwired cables in a manner that the interfaces are identical to the field wiring. The outputs from the control system are used as the simulation inputs of the plant model within the Win-NPA. With this closed-loop configuration, major transient events were simulated to check the performance of the implemented control system by comparing it with that of the control system model of the Win-NPA and that of the old hardware. The developed tool and the methodology were successfully applied to the hardware replacement project for Yonggwang (YGN) 3 and 4 feedwater control system (FWCS) in 2008. Several errors in the implemented control system were fixed through the performance validation tests and the operability tests. As a result, the control system of the YGN 3 and 4 has demonstrated an excellent control performance since then. On the basis of YGN 3 and 4 project experiences, we are performing a similar project in Ulchin (UCN) 3 and 4. This methodology can also be applied to other NPPs under construction as a tool for pre-operational dynamic tests. These performance tests before performing power ascension tests (PATs) are conducive to preventing unnecessary plant transients or unwanted reactor trips caused by hidden errors of control systems during PATs. (author)

  2. Validation of Clinical Testing for Warfarin Sensitivity

    Science.gov (United States)

    Langley, Michael R.; Booker, Jessica K.; Evans, James P.; McLeod, Howard L.; Weck, Karen E.

    2009-01-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 −1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses. PMID:19324988

  3. Phase 1 Validation Testing and Simulation for the WEC-Sim Open Source Code

    Science.gov (United States)

    Ruehl, K.; Michelen, C.; Gunawan, B.; Bosma, B.; Simmons, A.; Lomonaco, P.

    2015-12-01

    WEC-Sim is an open source code to model wave energy converters performance in operational waves, developed by Sandia and NREL and funded by the US DOE. The code is a time-domain modeling tool developed in MATLAB/SIMULINK using the multibody dynamics solver SimMechanics, and solves the WEC's governing equations of motion using the Cummins time-domain impulse response formulation in 6 degrees of freedom. The WEC-Sim code has undergone verification through code-to-code comparisons; however validation of the code has been limited to publicly available experimental data sets. While these data sets provide preliminary code validation, the experimental tests were not explicitly designed for code validation, and as a result are limited in their ability to validate the full functionality of the WEC-Sim code. Therefore, dedicated physical model tests for WEC-Sim validation have been performed. This presentation provides an overview of the WEC-Sim validation experimental wave tank tests performed at the Oregon State University's Directional Wave Basin at Hinsdale Wave Research Laboratory. Phase 1 of experimental testing was focused on device characterization and completed in Fall 2015. Phase 2 is focused on WEC performance and scheduled for Winter 2015/2016. These experimental tests were designed explicitly to validate the performance of WEC-Sim code, and its new feature additions. Upon completion, the WEC-Sim validation data set will be made publicly available to the wave energy community. For the physical model test, a controllable model of a floating wave energy converter has been designed and constructed. The instrumentation includes state-of-the-art devices to measure pressure fields, motions in 6 DOF, multi-axial load cells, torque transducers, position transducers, and encoders. The model also incorporates a fully programmable Power-Take-Off system which can be used to generate or absorb wave energy. Numerical simulations of the experiments using WEC-Sim will be

  4. Development of a test rig and its application for validation and reliability testing of safety-critical software

    Energy Technology Data Exchange (ETDEWEB)

    Thai, N D; McDonald, A M [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs.

  5. Development of a test rig and its application for validation and reliability testing of safety-critical software

    International Nuclear Information System (INIS)

    Thai, N.D.; McDonald, A.M.

    1995-01-01

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs

  6. PUREX exhaust ventilation system installation test report

    International Nuclear Information System (INIS)

    Blackaby, W.B.

    1997-01-01

    This Acceptance Test Report validates the testing performed, the exceptions logged and resolved and certifies this portion of the SAMCONS has met all design and test criteria to perform as an operational system. The proper installation of the PUREX exhaust ventilation system components and wiring was systematically evaluated by performance of this procedure. Proper operation of PUREX exhaust fan inlet, outlet, and vortex damper actuators and limit switches were verified, using special test equipment, to be correct and installed wiring connections were verified by operation of this equipment

  7. Games and Scenarios for Real-Time System Validation

    DEFF Research Database (Denmark)

    Li, Shuhao

    This thesis presents research on the validation of real-time embedded software systems in the context of model-based development. The thesis proposes scenario-based and game-theoretic approaches to system analysis, verification, synthesis and testing to address the challenges that arise from....... By linking our prototype translators with existing model checker Uppaal and game solver Uppaal-Tiga, we show that these methods contribute to the interaction correctness and timeliness of early system designs. The thesis also shows that testing a real-time reactive system can be viewed as playing a timed...... communicating real-time systems can be modeled and specified with LSC. By translating LSC to timed automata (TAs), we reduce scenario-based model consistency checking and property verification to CTL real-time model checking problems, and reduce scenario-based synthesis to a timed game solving problem...

  8. Validating High-Stakes Testing Programs.

    Science.gov (United States)

    Kane, Michael

    2002-01-01

    Makes the point that the interpretations and use of high-stakes test scores rely on policy assumptions about what should be taught and the content standards and performance standards that should be applied. The assumptions built into an assessment need to be subjected to scrutiny and criticism if a strong case is to be made for the validity of the…

  9. Validity and Reliability of the Arabic Token Test for Children

    Science.gov (United States)

    Alkhamra, Rana A.; Al-Jazi, Aya B.

    2016-01-01

    Background: The Token Test for Children (2nd edition) (TTFC) is a measure for assessing receptive language. In this study we describe the translation process, validity and reliability of the Arabic Token Test for Children (A-TTFC). Aims: The aim of this study is to translate, validate and establish the reliability of the Arabic Token Test for…

  10. Conceptualizing Essay Tests' Reliability and Validity: From Research to Theory

    Science.gov (United States)

    Badjadi, Nour El Imane

    2013-01-01

    The current paper on writing assessment surveys the literature on the reliability and validity of essay tests. The paper aims to examine the two concepts in relationship with essay testing as well as to provide a snapshot of the current understandings of the reliability and validity of essay tests as drawn in recent research studies. Bearing in…

  11. Construction of Valid and Reliable Test for Assessment of Students

    Science.gov (United States)

    Osadebe, P. U.

    2015-01-01

    The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…

  12. Development and preliminary validation of an interactive remote physical therapy system.

    Science.gov (United States)

    Mishra, Anup K; Skubic, Marjorie; Abbott, Carmen

    2015-01-01

    In this paper, we present an interactive physical therapy system (IPTS) for remote quantitative assessment of clients in the home. The system consists of two different interactive interfaces connected through a network, for a real-time low latency video conference using audio, video, skeletal, and depth data streams from a Microsoft Kinect. To test the potential of IPTS, experiments were conducted with 5 independent living senior subjects in Kansas City, MO. Also, experiments were conducted in the lab to validate the real-time biomechanical measures calculated using the skeletal data from the Microsoft Xbox 360 Kinect and Microsoft Xbox One Kinect, with ground truth data from a Vicon motion capture system. Good agreements were found in the validation tests. The results show potential capabilities of the IPTS system to provide remote physical therapy to clients, especially older adults, who may find it difficult to visit the clinic.

  13. The test-retest reliability and criterion validity of a high-intensity, netball-specific circuit test: The Net-Test.

    Science.gov (United States)

    Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T

    2018-04-12

    To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. BENDER GESTALT VISUALMOTOR TEST AND CARAS TEST: A EXAM OF CONSTRUCT VALIDITY

    Directory of Open Access Journals (Sweden)

    Cesar Merino Soto

    2011-12-01

    Full Text Available Research with new versions of the Bender Gestalt Test (TGB has hardly attracted attention to the researchers of the Hispanic world, onsidering that this test is one of the most widely used psychological assessments. This study evaluates the construct validity of the modified version of TGB for children, elative to sustainedattention assessed by the Caras Test. Both tests were applied to 90 children, aged between 5 and 8, in standardized conditions. The esults indicate that the shared variance between the two measures is zero, even when applied disattenuated correlations for measurement error; also, no non-linear patterns were detected between the two variables. These correlations were consistent in the total sample and among subgroups of children. We discuss these results with respect to the limits of validity of this modified version of TGB in the Spanish language.

  15. Modeling Run Test Validity: A Meta-Analytic Approach

    National Research Council Canada - National Science Library

    Vickers, Ross

    2002-01-01

    .... This study utilized data from 166 samples (N = 5,757) to test the general hypothesis that differences in testing methods could account for the cross-situational variation in validity. Only runs >2 km...

  16. Validation of Patient-Reported Outcomes Measurement Information System (PROMIS) computerized adaptive tests in cervical spine surgery.

    Science.gov (United States)

    Boody, Barrett S; Bhatt, Surabhi; Mazmudar, Aditya S; Hsu, Wellington K; Rothrock, Nan E; Patel, Alpesh A

    2018-03-01

    OBJECTIVE The Patient-Reported Outcomes Measurement Information System (PROMIS), which is funded by the National Institutes of Health, is a set of adaptive, responsive assessment tools that measures patient-reported health status. PROMIS measures have not been validated for surgical patients with cervical spine disorders. The objective of this project is to evaluate the validity (e.g., convergent validity, known-groups validity, responsiveness to change) of PROMIS computer adaptive tests (CATs) for pain behavior, pain interference, and physical function in patients undergoing cervical spine surgery. METHODS The legacy outcome measures Neck Disability Index (NDI) and SF-12 were used as comparisons with PROMIS measures. PROMIS CATs, NDI-10, and SF-12 measures were administered prospectively to 59 consecutive tertiary hospital patients who were treated surgically for degenerative cervical spine disorders. A subscore of NDI-5 was calculated from NDI-10 by eliminating the lifting, headaches, pain intensity, reading, and driving sections and multiplying the final score by 4. Assessments were administered preoperatively (baseline) and postoperatively at 6 weeks and 3 months. Patients presenting for revision surgery, tumor, infection, or trauma were excluded. Participants completed the measures in Assessment Center, an online data collection tool accessed by using a secure login and password on a tablet computer. Subgroup analysis was also performed based on a primary diagnosis of either cervical radiculopathy or cervical myelopathy. RESULTS Convergent validity for PROMIS CATs was supported with multiple statistically significant correlations with the existing legacy measures, NDI and SF-12, at baseline. Furthermore, PROMIS CATs demonstrated known-group validity and identified clinically significant improvements in all measures after surgical intervention. In the cervical radiculopathy and myelopathic cohorts, the PROMIS measures demonstrated similar responsiveness to the

  17. Oak Ridge Reservation Public Warning Siren System Annual Test Report

    International Nuclear Information System (INIS)

    R. F. Gee

    2000-01-01

    The full operational test of the Oak Ridge Reservation (ORR) Public Warning Siren System (PWSS) was successfully conducted on September 27, 2000. The annual test is a full-scale sounding of the individual siren systems around each of the three Department of Energy (DOE) sites in Oak Ridge, Tennessee. The purpose of the annual test is to demonstrate and validate the siren systems' ability to alert personnel outdoors in the Immediate Notification Zones (INZ) (approximately two miles) around each site. The success of this test is based on two critical functions of the siren system. The first function is system operability. The system is considered operable if 90% of the sirens are operational. System diagnostics and direct field observations were used to validate the operability of the siren systems. Based on the diagnostic results and field observations, greater than 90% of the sirens were considered operational. The second function is system audibility. The system is considered audible if the siren could be heard in the immediate notification zones around each of the three sites. Direct field observations, along with sound level measurements, were used to validate the audibility of the siren system. Based on the direct field observations and sound level measurements, the siren system was considered audible. The combination of field observations, system diagnostic status reports, and sound level measurements provided a high level of confidence that the system met and would meet operational requirements upon demand. As part of the overall system test, the Tennessee Emergency Management Agency (TEMA) activated the Emergency Alerting System (EAS), which utilized area radio stations to make announcements regarding the test and to remind residents of what to do in the event of an actual emergency

  18. The validation of Huffaz Intelligence Test (HIT)

    Science.gov (United States)

    Rahim, Mohd Azrin Mohammad; Ahmad, Tahir; Awang, Siti Rahmah; Safar, Ajmain

    2017-08-01

    In general, a hafiz who can memorize the Quran has many specialties especially in respect to their academic performances. In this study, the theory of multiple intelligences introduced by Howard Gardner is embedded in a developed psychometric instrument, namely Huffaz Intelligence Test (HIT). This paper presents the validation and the reliability of HIT of some tahfiz students in Malaysia Islamic schools. A pilot study was conducted involving 87 huffaz who were randomly selected to answer the items in HIT. The analysis method used includes Partial Least Square (PLS) on reliability, convergence and discriminant validation. The study has validated nine intelligences. The findings also indicated that the composite reliabilities for the nine types of intelligences are greater than 0.8. Thus, the HIT is a valid and reliable instrument to measure the multiple intelligences among huffaz.

  19. Gamma spectrometric validation of measurements test of radionuclides in food matrices

    International Nuclear Information System (INIS)

    Rosa, Mychelle M.L.; Custodio, Luis G.; Bonifacio, Rodrigo L.; Taddei, Maria Helena T.

    2013-01-01

    In a testing laboratory the quality system encompasses a set of activities planned and systematic, which ensure the traceability process of an analysis, which is based on the standards NBR ISO/TEC 17025. With the need for analysis of radionuclides in food products to meet the requirements of import and export, accreditation of testing on this standard becomes increasingly necessary. The Gamma Spectrometry is a technique used for direct determination of radionuclides in different matrices, among them the food, being possible the simultaneous determination of different radionuclides in the same sample without the need for a chemical separation. In the process of Accreditation the methodology validation is an important step that includes testing accuracy, traceability, linearity and recovery. This paper describes the procedures used to validate the assay for determining radionuclides using gamma spectrometry in food. These procedures were performed through analysis of a certificated reference material by the International Atomic Energy Agency (IAEA Soil 327), analysis of samples of milk powder prepared from the doping with certified liquid standards also by the results obtained in the participation of tests of proficiency in analysis of environmental samples. (author)

  20. Independent validation of the MMPI-2-RF Somatic/Cognitive and Validity scales in TBI Litigants tested for effort.

    Science.gov (United States)

    Youngjohn, James R; Wershba, Rebecca; Stevenson, Matthew; Sturgeon, John; Thomas, Michael L

    2011-04-01

    The MMPI-2 Restructured Form (MMPI-2-RF; Ben-Porath & Tellegen, 2008) is replacing the MMPI-2 as the most widely used personality test in neuropsychological assessment, but additional validation studies are needed. Our study examines MMPI-2-RF Validity scales and the newly created Somatic/Cognitive scales in a recently reported sample of 82 traumatic brain injury (TBI) litigants who either passed or failed effort tests (Thomas & Youngjohn, 2009). The restructured Validity scales FBS-r (restructured symptom validity), F-r (restructured infrequent responses), and the newly created Fs (infrequent somatic responses) were not significant predictors of TBI severity. FBS-r was significantly related to passing or failing effort tests, and Fs and F-r showed non-significant trends in the same direction. Elevations on the Somatic/Cognitive scales profile (MLS-malaise, GIC-gastrointestinal complaints, HPC-head pain complaints, NUC-neurological complaints, and COG-cognitive complaints) were significant predictors of effort test failure. Additionally, HPC had the anticipated paradoxical inverse relationship with head injury severity. The Somatic/Cognitive scales as a group were better predictors of effort test failure than the RF Validity scales, which was an unexpected finding. MLS arose as the single best predictor of effort test failure of all RF Validity and Somatic/Cognitive scales. Item overlap analysis revealed that all MLS items are included in the original MMPI-2 Hy scale, making MLS essentially a subscale of Hy. This study validates the MMPI-2-RF as an effective tool for use in neuropsychological assessment of TBI litigants.

  1. A Vehicle Management End-to-End Testing and Analysis Platform for Validation of Mission and Fault Management Algorithms to Reduce Risk for NASAs Space Launch System

    Science.gov (United States)

    Trevino, Luis; Johnson, Stephen B.; Patterson, Jonathan; Teare, David

    2015-01-01

    The engineering development of the National Aeronautics and Space Administration's (NASA) new Space Launch System (SLS) requires cross discipline teams with extensive knowledge of launch vehicle subsystems, information theory, and autonomous algorithms dealing with all operations from pre-launch through on orbit operations. The nominal and off-nominal characteristics of SLS's elements and subsystems must be understood and matched with the autonomous algorithm monitoring and mitigation capabilities for accurate control and response to abnormal conditions throughout all vehicle mission flight phases, including precipitating safing actions and crew aborts. This presents a large and complex systems engineering challenge, which is being addressed in part by focusing on the specific subsystems involved in the handling of off-nominal mission and fault tolerance with response management. Using traditional model-based system and software engineering design principles from the Unified Modeling Language (UML) and Systems Modeling Language (SysML), the Mission and Fault Management (M&FM) algorithms for the vehicle are crafted and vetted in Integrated Development Teams (IDTs) composed of multiple development disciplines such as Systems Engineering (SE), Flight Software (FSW), Safety and Mission Assurance (S&MA) and the major subsystems and vehicle elements such as Main Propulsion Systems (MPS), boosters, avionics, Guidance, Navigation, and Control (GNC), Thrust Vector Control (TVC), and liquid engines. These model-based algorithms and their development lifecycle from inception through FSW certification are an important focus of SLS's development effort to further ensure reliable detection and response to off-nominal vehicle states during all phases of vehicle operation from pre-launch through end of flight. To test and validate these M&FM algorithms a dedicated test-bed was developed for full Vehicle Management End-to-End Testing (VMET). For addressing fault management (FM

  2. Test anxiety and the validity of cognitive tests: A confirmatory factor analysis perspective and some empirical findings

    NARCIS (Netherlands)

    Wicherts, J.M.; Zand Scholten, A.

    2010-01-01

    The validity of cognitive ability tests is often interpreted solely as a function of the cognitive abilities that these tests are supposed to measure, but other factors may be at play. The effects of test anxiety on the criterion related validity (CRV) of tests was the topic of a recent study by

  3. A validation system for data preservation in HEP

    International Nuclear Information System (INIS)

    Kemp, Yves; Strutz, Marco; Hessling, Hermann

    2012-01-01

    Preserving data from past experiments and preserving the ability to perform analysis with old data is of growing importance in many domains of science, including High Energy Physics (HEP). A study group on this issue, DPHEP, has been established in this field to provide guidelines and a structure for international collaboration on data preservation projects in HEP. This contribution presents a framework that allows experimentalists to validate their software against a previously defined set of tests in an automated way. The framework has been designed with a special focus for longevity, as it makes use of open protocols, has a modular design and is based on simple communication mechanisms. On the fabrics side, tests are carried out in a virtual environment using a cloud infrastructure. Within the framework, it is easy to run validation tests on different hardware platforms, or different major or minor versions of operating systems. Experts from IT or the experiments can automatically detect failures in the test procedure by the help of reporting tools. Hence, appropriate actions can be taken in a timely manner. The design and important implementation aspects of the framework are shown and first experiences from early-bird users will be presented.

  4. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  5. An Integrated Approach to Establish Validity and Reliability of Reading Tests

    Science.gov (United States)

    Razi, Salim

    2012-01-01

    This study presents the processes of developing and establishing reliability and validity of a reading test by administering an integrative approach as conventional reliability and validity measures superficially reveals the difficulty of a reading test. In this respect, analysing vocabulary frequency of the test is regarded as a more eligible way…

  6. Guidelines for the verification and validation of expert system software and conventional software: Validation scenarios. Volume 6

    International Nuclear Information System (INIS)

    Mirsky, S.M.; Hayes, J.E.; Miller, L.A.

    1995-03-01

    This report is the sixth volume in a series of reports describing the results of the Expert System Verification and Validation (V ampersand V) project which is jointly funded by the US Nuclear Regulatory Commission and the Electric Power Research Institute. The ultimate objective is the formulation of guidelines for the V ampersand V of expert systems for use in nuclear power applications. This activity was concerned with the development of a methodology for selecting validation scenarios and subsequently applying it to two expert systems used for nuclear utility applications. Validation scenarios were defined and classified into five categories: PLANT, TEST, BASICS, CODE, and LICENSING. A sixth type, REGRESSION, is a composite of the others and refers to the practice of using trusted scenarios to ensure that modifications to software did not change unmodified functions. Rationale was developed for preferring scenarios selected from the categories in the order listed and for determining under what conditions to select scenarios from other types. A procedure incorporating all of the recommendations was developed as a generalized method for generating validation scenarios. The procedure was subsequently applied to two expert systems used in the nuclear industry and was found to be effective, given that an experienced nuclear engineer made the final scenario selections. A method for generating scenarios directly from the knowledge base component was suggested

  7. Guidelines for the verification and validation of expert system software and conventional software: Validation scenarios. Volume 6

    Energy Technology Data Exchange (ETDEWEB)

    Mirsky, S.M.; Hayes, J.E.; Miller, L.A. [Science Applications International Corp., McLean, VA (United States)

    1995-03-01

    This report is the sixth volume in a series of reports describing the results of the Expert System Verification and Validation (V&V) project which is jointly funded by the US Nuclear Regulatory Commission and the Electric Power Research Institute. The ultimate objective is the formulation of guidelines for the V&V of expert systems for use in nuclear power applications. This activity was concerned with the development of a methodology for selecting validation scenarios and subsequently applying it to two expert systems used for nuclear utility applications. Validation scenarios were defined and classified into five categories: PLANT, TEST, BASICS, CODE, and LICENSING. A sixth type, REGRESSION, is a composite of the others and refers to the practice of using trusted scenarios to ensure that modifications to software did not change unmodified functions. Rationale was developed for preferring scenarios selected from the categories in the order listed and for determining under what conditions to select scenarios from other types. A procedure incorporating all of the recommendations was developed as a generalized method for generating validation scenarios. The procedure was subsequently applied to two expert systems used in the nuclear industry and was found to be effective, given that an experienced nuclear engineer made the final scenario selections. A method for generating scenarios directly from the knowledge base component was suggested.

  8. Validity and Reliability of a Medicine Ball Explosive Power Test.

    Science.gov (United States)

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  9. A proactive alarm reduction method and its human factors validation test for a main control room for SMART

    International Nuclear Information System (INIS)

    Jang, Gwi-sook; Suh, Sang-moon; Kim, Sa-kil; Suh, Yong-suk; Park, Je-yun

    2013-01-01

    Highlights: ► A proactive alarm reduction method improves effectiveness on the alarm reduction. ► The method suppresses alarms based on the ECA rules and facts for the alarm reduction under an alarm flood situation. ► The alarm reduction logics are supplemented to a high hit ratio of the reduction logics during on-line operations. ► The method is validated by human factors validation test based on regulatory requirements. -- Abstract: Conventional alarm systems tend to overwhelm operators during a transient because of a large number of nearly simultaneous annunciator activations with varying degrees of relevance to operator tasks. Thus alarm processing techniques have developed to support operators in coping with the volume of alarms, to identify which alarms are significant, and to reduce the need for operators to infer the plant conditions. This paper proposes a proactive alarm reduction method for SMART (System-integrated Modular Advanced ReacTor) whereby based on the contents of the past operating effects alarm reduction is carried out during the next transient. We designed and implemented the proactive alarm reduction system and constructed the environment for the human factors validation test. Also, eight subjects actually working in a nuclear power plant (NPP) tested the practical effectiveness of the proposed proactive alarm reduction method according to the procedure of human factors validation test under a dynamic simulation of a partial scope for an NPP.

  10. How Can Consumers Be Sure a Genetic Test Is Valid and Useful?

    Science.gov (United States)

    ... a genetic test is valid and useful? How can consumers be sure a genetic test is valid ... particular gene or genetic change. In other words, can the test accurately detect whether a specific genetic ...

  11. Modification and Validation of an Automotive Data Processing Unit, Compessed Video System, and Communications Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1997-04-01

    The primary purpose of the "modification and validation of an automotive data processing unit (DPU), compressed video system, and communications equipment" cooperative research and development agreement (CRADA) was to modify and validate both hardware and software, developed by Scientific Atlanta, Incorporated (S-A) for defense applications (e.g., rotary-wing airplanes), for the commercial sector surface transportation domain (i.e., automobiles and trucks). S-A also furnished a state-of-the-art compressed video digital storage and retrieval system (CVDSRS), and off-the-shelf data storage and transmission equipment to support the data acquisition system for crash avoidance research (DASCAR) project conducted by Oak Ridge National Laboratory (ORNL). In turn, S-A received access to hardware and technology related to DASCAR. DASCAR was subsequently removed completely and installation was repeated a number of times to gain an accurate idea of complete installation, operation, and removal of DASCAR. Upon satisfactory completion of the DASCAR construction and preliminary shakedown, ORNL provided NHTSA with an operational demonstration of DASCAR at their East Liberty, OH test facility. The demonstration included an on-the-road demonstration of the entire data acquisition system using NHTSA'S test track. In addition, the demonstration also consisted of a briefing, containing the following: ORNL generated a plan for validating the prototype data acquisition system with regard to: removal of DASCAR from an existing vehicle, and installation and calibration in other vehicles; reliability of the sensors and systems; data collection and transmission process (data integrity); impact on the drivability of the vehicle and obtrusiveness of the system to the driver; data analysis procedures; conspicuousness of the vehicle to other drivers; and DASCAR installation and removal training and documentation. In order to identify any operational problems not captured by the systems

  12. Computer-aided test selection and result validation-opportunities and pitfalls

    DEFF Research Database (Denmark)

    McNair, P; Brender, J; Talmon, J

    1998-01-01

    /or to increase cost-efficiency). Our experience shows that there is a practical limit to the extent of exploitation of the principle of dynamic test scheduling, unless it is automated in one way or the other. This paper analyses some issues of concern related to the profession of clinical biochemistry, when......Dynamic test scheduling is concerned with pre-analytical preprocessing of the individual samples within a clinical laboratory production by means of decision algorithms. The purpose of such scheduling is to provide maximal information with minimal data production (to avoid data pollution and...... implementing such dynamic test scheduling within a Laboratory Information System (and/or an advanced analytical workstation). The challenge is related to 1) generation of appropriately validated decision models, and 2) mastering consequences of analytical imprecision and bias....

  13. Translation and validation of the Dutch new Knee Society Scoring System ©.

    Science.gov (United States)

    Van Der Straeten, Catherine; Witvrouw, Erik; Willems, Tine; Bellemans, Johan; Victor, Jan

    2013-11-01

    A new version of The Knee Society Knee Scoring System(©) (KSS) has recently been developed. Before this scale can be used in non-English-speaking populations, it has to be translated and validated for a particular population. We evaluated the construct and content validity, the test-retest reliability, and the internal consistency of the Dutch version of the New Knee Society KSS. A Dutch translation was performed using a forward-backward translation protocol. We tested the construct validity of the Dutch New KSS by comparing it with the Dutch versions of the WOMAC, Knee Injury and Osteoarthritis Outcome Score (KOOS), and SF-12 scores in 137 patients undergoing total knee arthroplasty (TKA). Content validity was assessed by comparing pre- and postoperative scores and by checking floor and ceiling effects. To evaluate test-retest reliability and consistency, 47 patients completed the questionnaire a second time with a mean of 8 days interval (range, 2-20 days) between tests. Construct validity was demonstrated because the Dutch New KSS correlated well with the Dutch WOMAC (r = -0.751; p Dutch KOOS (r = -0.723; p Dutch SF-12 (r = 0.569; p Dutch New KSS is an excellent instrument to evaluate TKA outcome in Dutch-speaking patients.

  14. Validation of measured friction by process tests

    DEFF Research Database (Denmark)

    Eriksen, Morten; Henningsen, Poul; Tan, Xincai

    The objective of sub-task 3.3 is to evaluate under actual process conditions the friction formulations determined by simulative testing. As regards task 3.3 the following tests have been used according to the original project plan: 1. standard ring test and 2. double cup extrusion test. The task...... has, however, been extended to include a number of new developed process tests: 3. forward rod extrusion test, 4. special ring test at low normal pressure, 5. spike test (especially developed for warm and hot forging). Validation of the measured friction values in cold forming from sub-task 3.1 has...... been made with forward rod extrusion, and very good agreement was obtained between the measured friction values in simulative testing and process testing....

  15. Construction and Evaluation of Reliability and Validity of Reasoning Ability Test

    Science.gov (United States)

    Bhat, Mehraj A.

    2014-01-01

    This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…

  16. Analysis of RVACS test 2F-L for COMMIX validation

    International Nuclear Information System (INIS)

    Tzanos, C.P.; Pedersen, D.R.

    1989-01-01

    The RVACS test 2F-L was analyzed to support the validation of COMMIX. This test is characterized by a power input of 50 kW, natural convection in the sodium pool, forced RVACS air circulation and a heat up period of 8 hours. At the beginning of the experiment the sodium pool was isothermal. After 7.5 hours the system reached near steady state with a temperature difference between the bottom and top of the pool of 96 degree C. The COMMIX predictions for the sodium pool temperatures and the air outlet temperatures were in good agreement with measurements. The maximum difference between predictions and measurements was ∼12 degree C. 4 refs., 5 figs

  17. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    BARNES, D.A.

    2000-06-01

    The purpose of this document is to describe tests performed to validate Revision 12.0 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be communicating to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab.

  18. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    International Nuclear Information System (INIS)

    BARNES, D.A.

    2000-01-01

    The purpose of this document is to describe tests performed to validate Revision 12.0 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be communicating to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab

  19. Verification and Validation Issues in Systems of Systems

    Directory of Open Access Journals (Sweden)

    Eric Honour

    2013-11-01

    Full Text Available The cutting edge in systems development today is in the area of "systems of systems" (SoS large networks of inter-related systems that are developed and managed separately, but that also perform collective activities. Such large systems typically involve constituent systems operating with different life cycles, often with uncoordinated evolution. The result is an ever-changing SoS in which adaptation and evolution replace the older engineering paradigm of "development". This short paper presents key thoughts about verification and validation in this environment. Classic verification and validation methods rely on having (a a basis of proof, in requirements and in operational scenarios, and (b a known system configuration to be proven. However, with constant SoS evolution, management of both requirements and system configurations are problematic. Often, it is impossible to maintain a valid set of requirements for the SoS due to the ongoing changes in the constituent systems. Frequently, it is even difficult to maintain a vision of the SoS operational use as users find new ways to adapt the SoS. These features of the SoS result in significant challenges for system proof. In addition to discussing the issues, the paper also indicates some of the solutions that are currently used to prove the SoS.

  20. Some guidance on preparing validation plans for the DART Full System Models.

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Genetha Anne; Hough, Patricia Diane; Hills, Richard Guy (Sandia National Laboratories, Albuquerque, NM)

    2009-03-01

    Planning is an important part of computational model verification and validation (V&V) and the requisite planning document is vital for effectively executing the plan. The document provides a means of communicating intent to the typically large group of people, from program management to analysts to test engineers, who must work together to complete the validation activities. This report provides guidelines for writing a validation plan. It describes the components of such a plan and includes important references and resources. While the initial target audience is the DART Full System Model teams in the nuclear weapons program, the guidelines are generally applicable to other modeling efforts. Our goal in writing this document is to provide a framework for consistency in validation plans across weapon systems, different types of models, and different scenarios. Specific details contained in any given validation plan will vary according to application requirements and available resources.

  1. Classifying snakebite in South Africa: Validating a scoring system ...

    African Journals Online (AJOL)

    Factors predictive of ATI and the optimal cut-off score for predicting an ATI were identified. These factors were then used to develop a standard scoring system. The score was then tested prospectively for accuracy in a new validation cohort consisting of 100 patients admitted for snakebite to our unit from 1 December 2014 to ...

  2. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    International Nuclear Information System (INIS)

    WANDLING, R.R.

    1999-01-01

    The purpose of this document is to describe tests performed to validate Revision 11.2 of the TMACS Monitor and Control System (TMCACS) and verify that the software functions as intended by design. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab

  3. Validation of Safety-Critical Systems for Aircraft Loss-of-Control Prevention and Recovery

    Science.gov (United States)

    Belcastro, Christine M.

    2012-01-01

    Validation of technologies developed for loss of control (LOC) prevention and recovery poses significant challenges. Aircraft LOC can result from a wide spectrum of hazards, often occurring in combination, which cannot be fully replicated during evaluation. Technologies developed for LOC prevention and recovery must therefore be effective under a wide variety of hazardous and uncertain conditions, and the validation framework must provide some measure of assurance that the new vehicle safety technologies do no harm (i.e., that they themselves do not introduce new safety risks). This paper summarizes a proposed validation framework for safety-critical systems, provides an overview of validation methods and tools developed by NASA to date within the Vehicle Systems Safety Project, and develops a preliminary set of test scenarios for the validation of technologies for LOC prevention and recovery

  4. Validation of Autonomous Space Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — System validation addresses the question "Will the system do the right thing?" When system capability includes autonomy, the question becomes more pointed. As NASA...

  5. Differential Weighting of Items to Improve University Admission Test Validity

    Directory of Open Access Journals (Sweden)

    Eduardo Backhoff Escudero

    2001-05-01

    Full Text Available This paper gives an evaluation of different ways to increase university admission test criterion-related validity, by differentially weighting test items. We compared four methods of weighting multiple-choice items of the Basic Skills and Knowledge Examination (EXHCOBA: (1 punishing incorrect responses by a constant factor, (2 weighting incorrect responses, considering the levels of error, (3 weighting correct responses, considering the item’s difficulty, based on the Classic Measurement Theory, and (4 weighting correct responses, considering the item’s difficulty, based on the Item Response Theory. Results show that none of these methods increased the instrument’s predictive validity, although they did improve its concurrent validity. It was concluded that it is appropriate to score the test by simply adding up correct responses.

  6. Guidelines for the verification and validation of expert system software and conventional software: Survey and documentation of expert system verification and validation methodologies. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Groundwater, E.H.; Miller, L.A.; Mirsky, S.M. [Science Applications International Corp., McLean, VA (United States)

    1995-03-01

    This report is the third volume in the final report for the Expert System Verification and Validation (V&V) project which was jointly sponsored by the Nuclear Regulatory Commission and the Electric Power Research Institute. The ultimate objective is the formulation of guidelines for the V&V of expert systems for use in nuclear power applications. The purpose of this activity was to survey and document techniques presently in use for expert system V&V. The survey effort included an extensive telephone interviewing program, site visits, and a thorough bibliographic search and compilation. The major finding was that V&V of expert systems is not nearly as established or prevalent as V&V of conventional software systems. When V&V was used for expert systems, it was almost always at the system validation stage after full implementation and integration usually employing the non-systematic dynamic method of {open_quotes}ad hoc testing.{close_quotes} There were few examples of employing V&V in the early phases of development and only weak sporadic mention of the possibilities in the literature. There is, however, a very active research area concerning the development of methods and tools to detect problems with, particularly, rule-based expert systems. Four such static-testing methods were identified which were not discovered in a comprehensive review of conventional V&V methods in an earlier task.

  7. A validity test of movie, television, and video-game ratings.

    Science.gov (United States)

    Walsh, D A; Gentile, D A

    2001-06-01

    Numerous studies have documented the potential effects on young audiences of violent content in media products, including movies, television programs, and computer and video games. Similar studies have evaluated the effects associated with sexual content and messages. Cumulatively, these effects represent a significant public health risk for increased aggressive and violent behavior, spread of sexually transmitted diseases, and pediatric pregnancy. In partial response to these risks and to public and legislative pressure, the movie, television, and gaming industries have implemented ratings systems intended to provide information about the content and appropriate audiences for different films, shows, and games. To test the validity of the current movie-, television-, and video game-rating systems. Panel study. Participants used the KidScore media evaluation tool, which evaluates films, television shows, and video games on 10 aspects, including the appropriateness of the media product for children based on age. When an entertainment industry rates a product as inappropriate for children, parent raters agree that it is inappropriate for children. However, parent raters disagree with industry usage of many of the ratings designating material suitable for children of different ages. Products rated as appropriate for adolescents are of the greatest concern. The level of disagreement varies from industry to industry and even from rating to rating. Analysis indicates that the amount of violent content and portrayals of violence are the primary markers for disagreement between parent raters and industry ratings. As 1 part of a solution to the complex public health problems posed by violent and sexually explicit media products, ratings can have value if used with caution. Parents and caregivers relying on the ratings systems to guide their children's use of media products should continue to monitor content independently. Industry ratings systems should be revised with input

  8. Integrated System Health Management (ISHM) Implementation in Rocket Engine Testing

    Science.gov (United States)

    Figueroa, Fernando; Morris, Jon; Turowski, Mark; Franzl, Richard; Walker, Mark; Kapadia, Ravi; Venkatesh, Meera

    2010-01-01

    A pilot operational ISHM capability has been implemented for the E-2 Rocket Engine Test Stand (RETS) and a Chemical Steam Generator (CSG) test article at NASA Stennis Space Center. The implementation currently includes an ISHM computer and a large display in the control room. The paper will address the overall approach, tools, and requirements. It will also address the infrastructure and architecture. Specific anomaly detection algorithms will be discussed regarding leak detection and diagnostics, valve validation, and sensor validation. It will also describe development and use of a Health Assessment Database System (HADS) as a repository for measurements, health, configuration, and knowledge related to a system with ISHM capability. It will conclude with a discussion of user interfaces, and a description of the operation of the ISHM system prior, during, and after testing.

  9. Performance Test Results of Safety I and C Systems of SMART MMIS

    International Nuclear Information System (INIS)

    Suh, Yong Suk; Keum, Jong Yong; Jeong, Kwang Il; Lee, Joon Ku; Lee, Sang Seok; Kim, Kwan Woong

    2011-01-01

    KAERI has developed SMART (System-integrated Modular Advanced ReacTor), a 330MWt integral pressurized light water reactor that integrates four reactor coolant pumps, one pressurizer, eight steam generators, and one reactor core into a reactor vessel, since 1997 and submitted a SSAR (Standard design Safety Analysis Report) to Korea institute of nuclear safety (KINS) at the end of 2010 for the purpose of achieving the standard design approval (SDA) by the end of 2011. SMART MMIS has been designed with fully digitalized systems. Non-safety instrumentation and control (I and C) systems are designed based on the commercial distributed control systems. The safety I and C systems are designed using a new platform that was developed and validated by KAERI. Safety I and C systems are modularized using the platform. In the protection systems (PSs), datalinks are used to transmit data in a one-way direction in order to meet the independency requirement. In the engineered safety features-component control system (ESF-CCS), network switch devices (NSDs) are used to connect the group and loop controllers. The NSD was also newly developed and validated by KAERI. After validating the platform and NSD, a test facility was developed using the platform and NSDs to validate the performance of safety I and C systems. This paper presents the development and test results from the test facility

  10. Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review.

    Science.gov (United States)

    Greher, Michael R; Wodushek, Thomas R

    2017-03-01

    Performance validity testing refers to neuropsychologists' methodology for determining whether neuropsychological test performances completed in the course of an evaluation are valid (ie, the results of true neurocognitive function) or invalid (ie, overly impacted by the patient's effort/engagement in testing). This determination relies upon the use of either standalone tests designed for this sole purpose, or specific scores/indicators embedded within traditional neuropsychological measures that have demonstrated this utility. In response to a greater appreciation for the critical role that performance validity issues play in neuropsychological testing and the need to measure this variable to the best of our ability, the scientific base for performance validity testing has expanded greatly over the last 20 to 30 years. As such, the majority of current day neuropsychologists in the United States use a variety of measures for the purpose of performance validity testing as part of everyday forensic and clinical practice and address this issue directly in their evaluations. The following is the first article of a 2-part series that will address the evolution of performance validity testing in the field of neuropsychology, both in terms of the science as well as the clinical application of this measurement technique. The second article of this series will review performance validity tests in terms of methods for development of these measures, and maximizing of diagnostic accuracy.

  11. Real time test bed development for power system operation, control and cyber security

    Science.gov (United States)

    Reddi, Ram Mohan

    The operation and control of the power system in an efficient way is important in order to keep the system secure, reliable and economical. With advancements in smart grid, several new algorithms have been developed for improved operation and control. These algorithms need to be extensively tested and validated in real time before applying to the real electric power grid. This work focuses on the development of a real time test bed for testing and validating power system control algorithms, hardware devices and cyber security vulnerability. The test bed developed utilizes several hardware components including relays, phasor measurement units, phasor data concentrator, programmable logic controllers and several software tools. Current work also integrates historian for power system monitoring and data archiving. Finally, two different power system test cases are simulated to demonstrate the applications of developed test bed. The developed test bed can also be used for power system education.

  12. Validity of the Eating Attitude Test among Exercisers.

    Science.gov (United States)

    Lane, Helen J; Lane, Andrew M; Matheson, Hilary

    2004-12-01

    Theory testing and construct measurement are inextricably linked. To date, no published research has looked at the factorial validity of an existing eating attitude inventory for use with exercisers. The Eating Attitude Test (EAT) is a 26-item measure that yields a single index of disordered eating attitudes. The original factor analysis showed three interrelated factors: Dieting behavior (13-items), oral control (7-items), and bulimia nervosa-food preoccupation (6-items). The primary purpose of the study was to examine the factorial validity of the EAT among a sample of exercisers. The second purpose was to investigate relationships between eating attitudes scores and selected psychological constructs. In stage one, 598 regular exercisers completed the EAT. Confirmatory factor analysis (CFA) was used to test the single-factor, a three-factor model, and a four-factor model, which distinguished bulimia from food pre-occupation. CFA of the single-factor model (RCFI = 0.66, RMSEA = 0.10), the three-factor-model (RCFI = 0.74; RMSEA = 0.09) showed poor model fit. There was marginal fit for the 4-factor model (RCFI = 0.91, RMSEA = 0.06). Results indicated five-items showed poor factor loadings. After these 5-items were discarded, the three models were re-analyzed. CFA results indicated that the single-factor model (RCFI = 0.76, RMSEA = 0.10) and three-factor model (RCFI = 0.82, RMSEA = 0.08) showed poor fit. CFA results for the four-factor model showed acceptable fit indices (RCFI = 0.98, RMSEA = 0.06). Stage two explored relationships between EAT scores, mood, self-esteem, and motivational indices toward exercise in terms of self-determination, enjoyment and competence. Correlation results indicated that depressed mood scores positively correlated with bulimia and dieting scores. Further, dieting was inversely related with self-determination toward exercising. Collectively, findings suggest that a 21-item four-factor model shows promising validity coefficients among

  13. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Evaporation over sump surface in containment studies: code validation on TOSQAN tests

    International Nuclear Information System (INIS)

    Malet, J.; Gelain, T.; Degrees du Lou, O.; Daru, V.

    2011-01-01

    During the course of a severe accident in a Nuclear Power Plant, water can be collected in the sump containment through steam condensation on walls and spray systems activation. The objective of this paper is to present code validation on evaporative sump tests performed on the TOSQAN facility. The ASTEC-CPA code is used as a lumped-parameter code and specific user-defined-functions are developed for the TONUS-CFD code. The tests are air-steam tests, as well as tests with other non-condensable gases (He, CO 2 and SF 6 ) under steady and transient conditions. The results show a good agreement between codes and experiments, indicating a good behaviour of the sump models in both codes. (author)

  15. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  16. Development of an automated testing system for verification and validation of nuclear data

    International Nuclear Information System (INIS)

    Triplett, B. S.; Anghaie, S.; White, M. C.

    2008-01-01

    Verification and validation of nuclear data is critical to the accuracy of both stochastic and deterministic particle transport codes. In order to effectively test a set of nuclear data, the data must be applied to a wide variety of transport problems. Performing this task in a timely, efficient manner is tedious. The nuclear data team at Los Alamos National Laboratory (LANL) in collaboration with the University of Florida is developing a methodology to automate the process of nuclear data verification and validation. The International Criticality Safety Benchmark Experiment Project (ICSBEP) provides a set of criticality problems that may be used to evaluate nuclear data. This process tests a number of data libraries using cases from the ICSBEP benchmark set to demonstrate how automation of these tasks may reduce errors and increase efficiency. The process is driven by an integrated set of Python scripts. Material and geometry data may be read from an existing code input file to generate a standardized template or the template may be generated directly by the user The user specifies the desired precision and other vital problem parameters. The Python scripts generate input decks for multiple transport codes from these templates, run and monitor individual jobs, and parse the relevant output. This output can then be used to generate reports directly or can be stored into a database for later analysis. This methodology eases the burden on the user by reducing the amount of time and effort required for obtaining and compiling calculation results. (authors)

  17. Validation of Metagenomic Next-Generation Sequencing Tests for Universal Pathogen Detection.

    Science.gov (United States)

    Schlaberg, Robert; Chiu, Charles Y; Miller, Steve; Procop, Gary W; Weinstock, George

    2017-06-01

    - Metagenomic sequencing can be used for detection of any pathogens using unbiased, shotgun next-generation sequencing (NGS), without the need for sequence-specific amplification. Proof-of-concept has been demonstrated in infectious disease outbreaks of unknown causes and in patients with suspected infections but negative results for conventional tests. Metagenomic NGS tests hold great promise to improve infectious disease diagnostics, especially in immunocompromised and critically ill patients. - To discuss challenges and provide example solutions for validating metagenomic pathogen detection tests in clinical laboratories. A summary of current regulatory requirements, largely based on prior guidance for NGS testing in constitutional genetics and oncology, is provided. - Examples from 2 separate validation studies are provided for steps from assay design, and validation of wet bench and bioinformatics protocols, to quality control and assurance. - Although laboratory and data analysis workflows are still complex, metagenomic NGS tests for infectious diseases are increasingly being validated in clinical laboratories. Many parallels exist to NGS tests in other fields. Nevertheless, specimen preparation, rapidly evolving data analysis algorithms, and incomplete reference sequence databases are idiosyncratic to the field of microbiology and often overlooked.

  18. Validation of programmable industrial automation systems for safety critical applications in NPP's; dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems cannot be totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. This paper describes a prototype dynamic testing harness for programmable digital systems developed at VTT. (author). 12 refs, 2 figs, 2 tabs

  19. Development and Validation of a Test for Bulimia.

    Science.gov (United States)

    Smith, Marcia C.; Thelen, Mark H.

    1984-01-01

    Developed the Bulimia Test (BULIT) based on responses of clinically identified females (N=18) and normal female college students (N=119) to preliminary test items. Results showed that the BULIT provided an objective, reliable, and valid measure by which to identify individuals with symptoms of bulimia. (Instrument is appended.) (LLL)

  20. Components and system tests on the RFX toroidal power supply

    International Nuclear Information System (INIS)

    Toigo, V.; Zanotto, L.; Gaio, E.; Perna, M.; Bordignon, P.; Coffetti, A.; Novaro, R.; Bertolotto, P.; Rinaldi, E.; Villa, G.

    2005-01-01

    The paper deals with the component and system tests performed on the new toroidal power supply system of the RFX experiment. The high technological innovation of the system required a deep experimental characterization and validation campaign; special factory tests were performed on prototypes of single components aimed at verifying the most critical design aspects. Consequently an articulated series of tests were performed, based on a step-by-step approach to achieve the desired coordinate operation of the whole system. The test procedures and the most significant results are described in the paper

  1. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    De Groot, Sonja; Balvers, Inge J. M.; Kouwenhoven, Sanne M.; Janssen, Thomas W. J.

    2012-01-01

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  2. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    de Groot, Sonja; Balvers, Inge J.M.; Kouwenhoven, Sanne M.; Janssen, Thomas W.J.

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  3. Validation of the Vanderbilt Holistic Face Processing Test.

    Science.gov (United States)

    Wang, Chao-Chih; Ross, David A; Gauthier, Isabel; Richler, Jennifer J

    2016-01-01

    The Vanderbilt Holistic Face Processing Test (VHPT-F) is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014). In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the same construct as the composite task, which is group-based measure at the center of the large literature on holistic face processing. In Experiment 1, we found a significant correlation between holistic processing measured in the VHPT-F and the composite task. Although this correlation was small, it was comparable to the correlation between holistic processing measured in the composite task with the same faces, but different target parts (top or bottom), which represents a reasonable upper limit for correlations between the composite task and another measure of holistic processing. These results confirm the validity of the VHPT-F by demonstrating shared variance with another measure of holistic processing based on the same operational definition. These results were replicated in Experiment 2, but only when the demographic profile of our sample matched that of Experiment 1.

  4. Validation of the Vanderbilt Holistic Face Processing Test.

    Directory of Open Access Journals (Sweden)

    Chao-Chih Wang

    2016-11-01

    Full Text Available The Vanderbilt Holistic Face Processing Test (VHPT-F is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014. In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the same construct as the composite task, which is group-based measure at the center of the large literature on holistic face processing. In Experiment 1, we found a significant correlation between holistic processing measured in the VHPT-F and the composite task. Although this correlation was small, it was comparable to the correlation between holistic processing measured in the composite task with the same faces, but different target parts (top or bottom, which represents a reasonable upper limit for correlations between the composite task and another measure of holistic processing. These results confirm the validity of the VHPT-F by demonstrating shared variance with another measure of holistic processing based on the same operational definition. These results were replicated in Experiment 2, but only when the demographic profile of our sample matched that of Experiment 1.

  5. Developing and Validating the Communication Function Classification System for Individuals with Cerebral Palsy

    Science.gov (United States)

    Hidecker, Mary Jo Cooley; Paneth, Nigel; Rosenbaum, Peter L.; Kent, Raymond D.; Lillie, Janet; Eulenberg, John B.; Chester, Ken, Jr.; Johnson, Brenda; Michalsen, Lauren; Evatt, Morgan; Taylor, Kara

    2011-01-01

    Aim: The purpose of this study was to create and validate the Communication Function Classification System (CFCS) for children with cerebral palsy (CP), for use by a wide variety of individuals who are interested in CP. This paper reports the content validity, interrater reliability, and test-retest reliability of the CFCS for children with CP.…

  6. Danish translation and validation of the International Skin Tear Advisory Panel Skin Tear Classification System

    DEFF Research Database (Denmark)

    Skiveren, J; Bermark, S; LeBlanc, K

    2015-01-01

    OBJECTIVE: The aim of this study was to translate, validate and establish reliability of the International Skin Tear Classification System in Danish. METHOD: Phase 1 of the project involved the translation of the International Skin Tear Advisory Panel (ISTAP) Skin Tear Classification System......) and social and health-care assistants (non-RN) from both primary health care and a Danish university hospital in Copenhagen. Thirty photographs, with equal representation of the three types of skin tears, were selected to test validity. The photographs chosen were those originally used for internal...... and external validation by the ISTAP group. The subjects were approached in their place of work and invited to participate in the study and to attend an educational session related to skin tears. RESULTS: The Danish translation of the ISTAP classification system was tested on 270 non-wound specialists...

  7. A novel energy regeneration system for emulsion pump tests

    Energy Technology Data Exchange (ETDEWEB)

    Yilei, Li; Zhencai, Zhu; Guohua, Cao [China University of Mining and Technology, Xuzhou (China); Guoan, Chen [Command Academy of the Corps of Engineers, Xuzhou (China)

    2013-04-15

    A novel energy regeneration system based on cylinders and a rectifier valve for emulsion pump tests is presented and studied. The overall structure and working principles of this system are introduced. Both simulation and experiments are carried out to investigate the energy regeneration feasibility and capability of this novel system. The simulation and experimental results validate that this system is able to save energy and satisfy the test requirement. The energy recovery coefficient and overall energy regeneration coefficient of the test bench are 0.785 and 0.214, respectively. Measures to improve these two coefficients are also given accordingly after analysis of power loss. This novel system brings a new method of energy regeneration for emulsion pump tests.

  8. Performance testing of real-time AI systems using the activation framework

    International Nuclear Information System (INIS)

    Becker, L.; Duckworth, J.; Laznovsky, A.; Green, P.

    1992-01-01

    This paper describes methods for automated performance testing of real-time artificial intelligence systems using the Activation Framework software development tool. The Activation Framework is suitable for applications such as the diagnosis of power system failures, which require the interpretation of large volumes of data in real-time. The Activation Framework consists of tools for compiling groups of Expert Systems rules into executable code modules, for automatically generating code modules from high level system configuration descriptions, and for automatically generating command files for program compilation and linking. It includes an operating system environment which provides the code which is common from one real-time AI applications to the next. It also includes mechanisms, described here, for automatic performance testing. The principal emphasis of this paper is on a rule based language which is used to capture performance specifications. This specification is compiled into code modules which are used to automatically test the system. This testing can validate that the system meets performance requirements during development and after maintenance. A large number of tests can be randomly generated and executed and the correctness of the outputs automatically validated. The paper also describes graph directed testing methods to minimize the number of test runs required

  9. Development and testing of an integrated signal validation system for nuclear power plants

    International Nuclear Information System (INIS)

    Upadhayaya, B.R.; Kerlin, T.W.; Holbert, K.E.; Glockler, O.; Morgenstern, V.M.; Frei, Z.; Olvera, J.; Gaudio, P.J. Jr.

    1989-09-01

    The approach for signal validation, instrument fault isolation and characterization incorporates some of the methods used in the past, and new techniques developed under this project. The general architecture consists of parallel signal processing modules. Each of the modules performs a specific task. The current architecture consists of seven signal processing modules. There is no direct communication between the modules. Any cross information desired must be requested at the system executive level. 26 refs., 102 figs., 39 tabs

  10. Validation of a clinical critical thinking skills test in nursing.

    Science.gov (United States)

    Shin, Sujin; Jung, Dukyoo; Kim, Sungeun

    2015-01-27

    The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability.

  11. Flight critical system design guidelines and validation methods

    Science.gov (United States)

    Holt, H. M.; Lupton, A. O.; Holden, D. G.

    1984-01-01

    Efforts being expended at NASA-Langley to define a validation methodology, techniques for comparing advanced systems concepts, and design guidelines for characterizing fault tolerant digital avionics are described with an emphasis on the capabilities of AIRLAB, an environmentally controlled laboratory. AIRLAB has VAX 11/750 and 11/780 computers with an aggregate of 22 Mb memory and over 650 Mb storage, interconnected at 256 kbaud. An additional computer is programmed to emulate digital devices. Ongoing work is easily accessed at user stations by either chronological or key word indexing. The CARE III program aids in analyzing the capabilities of test systems to recover from faults. An additional code, the semi-Markov unreliability program (SURE) generates upper and lower reliability bounds. The AIRLAB facility is mainly dedicated to research on designs of digital flight-critical systems which must have acceptable reliability before incorporation into aircraft control systems. The digital systems would be too costly to submit to a full battery of flight tests and must be initially examined with the AIRLAB simulation capabilities.

  12. Validation of programmable industrial automation systems for safety critical applications in NPP's dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems can not totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. The prototype dynamic testing harness for programmable digital systems developed at the Technical Research Centre of Finland (VTT) is described in the presentation. (12 refs., 2 figs., 2 tabs.)

  13. Reproducibility and validity of the DynaPort KneeTest

    NARCIS (Netherlands)

    Mokkink, L.B.; Terwee, C.B.; Slikke, van der R.M.; Lummel, van R.C.; Benink, R.J.; Bouter, L.M.; Vet, de H.C.W.

    2005-01-01

    OBJECTIVE: To determine the reproducibility and validity of the DynaPort KneeTest, a performance-based test that measures quality of movement of patients undergoing total knee replacement (TKR). METHODS: A total of 92 patients with osteoarthritis (OA) of the knee performed the KneeTest twice on the

  14. Validity and reliability of the Myotest accelerometric system for the assessment of vertical jump height.

    Science.gov (United States)

    Casartelli, Nicola; Müller, Roland; Maffiuletti, Nicola A

    2010-11-01

    The aim of the present study was to verify the validity and reliability of the Myotest accelerometric system (Myotest SA, Sion, Switzerland) for the assessment of vertical jump height. Forty-four male basketball players (age range: 9-25 years) performed series of squat, countermovement and repeated jumps during 2 identical test sessions separated by 2-15 days. Flight height was simultaneously quantified with the Myotest system and validated photoelectric cells (Optojump). Two calculation methods were used to estimate the jump height from Myotest recordings: flight time (Myotest-T) and vertical takeoff velocity (Myotest-V). Concurrent validity was investigated comparing Myotest-T and Myotest-V to the criterion method (Optojump), and test-retest reliability was also examined. As regards validity, Myotest-T overestimated jumping height compared to Optojump (p 0.98), that is, excellent validity. Myotest-V overestimated jumping height compared to Optojump (p 12 cm), high limits of agreement ratios (>36%), and low ICCs (9 cm). In conclusion, Myotest-T is a valid and reliable method for the assessment of vertical jump height, and its use is legitimate for field-based evaluations, whereas Myotest-V is neither valid nor reliable.

  15. Experimental results and validation of a method to reconstruct forces on the ITER test blanket modules

    International Nuclear Information System (INIS)

    Zeile, Christian; Maione, Ivan A.

    2015-01-01

    Highlights: • An in operation force measurement system for the ITER EU HCPB TBM has been developed. • The force reconstruction methods are based on strain measurements on the attachment system. • An experimental setup and a corresponding mock-up have been built. • A set of test cases representing ITER relevant excitations has been used for validation. • The influence of modeling errors on the force reconstruction has been investigated. - Abstract: In order to reconstruct forces on the test blanket modules in ITER, two force reconstruction methods, the augmented Kalman filter and a model predictive controller, have been selected and developed to estimate the forces based on strain measurements on the attachment system. A dedicated experimental setup with a corresponding mock-up has been designed and built to validate these methods. A set of test cases has been defined to represent possible excitation of the system. It has been shown that the errors in the estimated forces mainly depend on the accuracy of the identified model used by the algorithms. Furthermore, it has been found that a minimum of 10 strain gauges is necessary to allow for a low error in the reconstructed forces.

  16. LADO as a Language Test: Issues of Validity

    Science.gov (United States)

    McNamara, Tim; Van Den Hazelkamp, Carolien; Verrips, Maaike

    2016-01-01

    This article brings together the theoretical field of language testing and the practical field of language analysis for the determination of the origin of asylum seekers. It considers what it would mean to think of language analysis as a form of language test, subject to the same validity constraints, and proposes a research agenda.

  17. Testing ESL sociopragmatics development and validation of a web-based test battery

    CERN Document Server

    Roever, Carsten; Elder, Catherine

    2014-01-01

    Testing of second language pragmatics has grown as a research area but still suffers from a tension between construct coverage and practicality. In this book, the authors describe the development and validation of a web-based test of second language pragmatics for learners of English. The test has a sociopragmatic orientation and strives for a broad coverage of the construct by assessing learners'' metapragmatic judgments as well as their ability to co-construct discourse. To ensure practicality, the test is delivered online and is scored partially automatically and partially by human raters.

  18. Guidelines for the verification and validation of expert system software and conventional software: Survey and documentation of expert system verification and validation methodologies. Volume 3

    International Nuclear Information System (INIS)

    Groundwater, E.H.; Miller, L.A.; Mirsky, S.M.

    1995-03-01

    This report is the third volume in the final report for the Expert System Verification and Validation (V ampersand V) project which was jointly sponsored by the Nuclear Regulatory Commission and the Electric Power Research Institute. The ultimate objective is the formulation of guidelines for the V ampersand V of expert systems for use in nuclear power applications. The purpose of this activity was to survey and document techniques presently in use for expert system V ampersand V. The survey effort included an extensive telephone interviewing program, site visits, and a thorough bibliographic search and compilation. The major finding was that V ampersand V of expert systems is not nearly as established or prevalent as V ampersand V of conventional software systems. When V ampersand V was used for expert systems, it was almost always at the system validation stage after full implementation and integration usually employing the non-systematic dynamic method of open-quotes ad hoc testing.close quotes There were few examples of employing V ampersand V in the early phases of development and only weak sporadic mention of the possibilities in the literature. There is, however, a very active research area concerning the development of methods and tools to detect problems with, particularly, rule-based expert systems. Four such static-testing methods were identified which were not discovered in a comprehensive review of conventional V ampersand V methods in an earlier task

  19. Integration and validation testing for PhEDEx, DBS and DAS with the PhEDEx LifeCycle agent

    CERN Document Server

    Wildish, Anthony

    2013-01-01

    The ever-increasing amount of data handled by the CMS dataflow and workflow management tools poses new challenges for cross-validation among different systems within CMS experiment at LHC. To approach this problem we developed an integration test suite based on the LifeCycle agent, a tool originally conceived for stress-testing new releases of PhEDEx, the CMS data-placement tool. The LifeCycle agent provides a framework for customising the test workflow in arbitrary ways, and can scale to levels of activity well beyond those seen in normal running. This means we can run realistic performance tests at scales not likely to be seen by the experiment for some years, or with custom topologies to examine particular situations that may cause concern some time in the future.The LifeCycle agent has recently been enhanced to become a general purpose integration and validation testing tool for major CMS services (PhEDEx, DBS, DAS). It allows cross-system integration tests of all three components to be performed in contr...

  20. Control and Non-Payload Communications (CNPC) Prototype Radio Validation Flight Test Report

    Science.gov (United States)

    Shalkhauser, Kurt A.; Ishac, Joseph A.; Iannicca, Dennis C.; Bretmersky, Steven C.; Smith, Albert E.

    2017-01-01

    This report provides an overview and results from the unmanned aircraft (UA) Control and Non-Payload Communications (CNPC) Generation 5 prototype radio validation flight test campaign. The radios used in the test campaign were developed under cooperative agreement NNC11AA01A between the NASA Glenn Research Center and Rockwell Collins, Inc., of Cedar Rapids, Iowa. Measurement results are presented for flight tests over hilly terrain, open water, and urban landscape, utilizing radio sets installed into a NASA aircraft and ground stations. Signal strength and frame loss measurement data are analyzed relative to time and aircraft position, specifically addressing the impact of line-of-sight terrain obstructions on CNPC data flow. Both the radio and flight test system are described.

  1. Space Launch System Scale Model Acoustic Test Ignition Overpressure Testing

    Science.gov (United States)

    Nance, Donald; Liever, Peter; Nielsen, Tanner

    2015-01-01

    The overpressure phenomenon is a transient fluid dynamic event occurring during rocket propulsion system ignition. This phenomenon results from fluid compression of the accelerating plume gas, subsequent rarefaction, and subsequent propagation from the exhaust trench and duct holes. The high-amplitude unsteady fluid-dynamic perturbations can adversely affect the vehicle and surrounding structure. Commonly known as ignition overpressure (IOP), this is an important design-to environment for the Space Launch System (SLS) that NASA is currently developing. Subscale testing is useful in validating and verifying the IOP environment. This was one of the objectives of the Scale Model Acoustic Test, conducted at Marshall Space Flight Center. The test data quantifies the effectiveness of the SLS IOP suppression system and improves the analytical models used to predict the SLS IOP environments. The reduction and analysis of the data gathered during the SMAT IOP test series requires identification and characterization of multiple dynamic events and scaling of the event waveforms to provide the most accurate comparisons to determine the effectiveness of the IOP suppression systems. The identification and characterization of the overpressure events, the waveform scaling, the computation of the IOP suppression system knockdown factors, and preliminary comparisons to the analytical models are discussed.

  2. Space Launch System Scale Model Acoustic Test Ignition Overpressure Testing

    Science.gov (United States)

    Nance, Donald K.; Liever, Peter A.

    2015-01-01

    The overpressure phenomenon is a transient fluid dynamic event occurring during rocket propulsion system ignition. This phenomenon results from fluid compression of the accelerating plume gas, subsequent rarefaction, and subsequent propagation from the exhaust trench and duct holes. The high-amplitude unsteady fluid-dynamic perturbations can adversely affect the vehicle and surrounding structure. Commonly known as ignition overpressure (IOP), this is an important design-to environment for the Space Launch System (SLS) that NASA is currently developing. Subscale testing is useful in validating and verifying the IOP environment. This was one of the objectives of the Scale Model Acoustic Test (SMAT), conducted at Marshall Space Flight Center (MSFC). The test data quantifies the effectiveness of the SLS IOP suppression system and improves the analytical models used to predict the SLS IOP environments. The reduction and analysis of the data gathered during the SMAT IOP test series requires identification and characterization of multiple dynamic events and scaling of the event waveforms to provide the most accurate comparisons to determine the effectiveness of the IOP suppression systems. The identification and characterization of the overpressure events, the waveform scaling, the computation of the IOP suppression system knockdown factors, and preliminary comparisons to the analytical models are discussed.

  3. CSNI Integral Test Facility Matrices for Validation of Best-Estimate Thermal-Hydraulic Computer Codes

    International Nuclear Information System (INIS)

    Glaeser, H.

    2008-01-01

    Internationally agreed Integral Test Facility (ITF) matrices for validation of realistic thermal hydraulic system computer codes were established. ITF development is mainly for Pressurised Water Reactors (PWRs) and Boiling Water Reactors (BWRs). A separate activity was for Russian Pressurised Water-cooled and Water-moderated Energy Reactors (WWER). Firstly, the main physical phenomena that occur during considered accidents are identified, test types are specified, and test facilities suitable for reproducing these aspects are selected. Secondly, a list of selected experiments carried out in these facilities has been set down. The criteria to achieve the objectives are outlined. In this paper some specific examples from the ITF matrices will also be provided. The matrices will be a guide for code validation, will be a basis for comparisons of code predictions performed with different system codes, and will contribute to the quantification of the uncertainty range of code model predictions. In addition to this objective, the construction of such a matrix is an attempt to record information which has been generated around the world over the last years, so that it is more accessible to present and future workers in that field than would otherwise be the case.

  4. Test-Retest Reliability and Predictive Validity of the Implicit Association Test in Children

    Science.gov (United States)

    Rae, James R.; Olson, Kristina R.

    2018-01-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many…

  5. Was the Conconi test validated by sporting success, expert opinion ...

    African Journals Online (AJOL)

    Was the Conconi test validated by sporting success, expert opinion or good science? ... Open Access DOWNLOAD FULL TEXT ... Despite scientific evidence to the contrary, a popular incremental field test for endurance athletes (Conconi Test) ...

  6. Validation of the Narrowing Beam Walking Test in Lower Limb Prosthesis Users.

    Science.gov (United States)

    Sawers, Andrew; Hafner, Brian

    2018-04-11

    To evaluate the content, construct, and discriminant validity of the Narrowing Beam Walking Test (NBWT), a performance-based balance test for lower limb prosthesis users. Cross-sectional study. Research laboratory and prosthetics clinic. Unilateral transtibial and transfemoral prosthesis users (N=40). Not applicable. Content validity was examined by quantifying the percentage of participants receiving maximum or minimum scores (ie, ceiling and floor effects). Convergent construct validity was examined using correlations between participants' NBWT scores and scores or times on existing clinical balance tests regularly administered to lower limb prosthesis users. Known-groups construct validity was examined by comparing NBWT scores between groups of participants with different fall histories, amputation levels, amputation etiologies, and functional levels. Discriminant validity was evaluated by analyzing the area under each test's receiver operating characteristic (ROC) curve. No minimum or maximum scores were recorded on the NBWT. NBWT scores demonstrated strong correlations (ρ=.70‒.85) with scores/times on performance-based balance tests (timed Up and Go test, Four Square Step Test, and Berg Balance Scale) and a moderate correlation (ρ=.49) with the self-report Activities-specific Balance Confidence scale. NBWT performance was significantly lower among participants with a history of falls (P=.003), transfemoral amputation (P=.011), and a lower mobility level (P.50 (ie, chance). The results provide strong evidence of content, construct, and discriminant validity for the NBWT as a performance-based test of balance ability. The evidence supports its use to assess balance impairments and fall risk in unilateral transtibial and transfemoral prosthesis users. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.

    Science.gov (United States)

    Nee, Robert J; Jull, Gwendolen A; Vicenzino, Bill; Coppieters, Michel W

    2012-05-01

    The validity of upper-limb neurodynamic tests (ULNTs) for detecting peripheral neuropathic pain (PNP) was assessed by reviewing the evidence on plausibility, the definition of a positive test, reliability, and concurrent validity. Evidence was identified by a structured search for peer-reviewed articles published in English before May 2011. The quality of concurrent validity studies was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool, where appropriate. Biomechanical and experimental pain data support the plausibility of ULNTs. Evidence suggests that a positive ULNT should at least partially reproduce the patient's symptoms and that structural differentiation should change these symptoms. Data indicate that this definition of a positive ULNT is reliable when used clinically. Limited evidence suggests that the median nerve test, but not the radial nerve test, helps determine whether a patient has cervical radiculopathy. The median nerve test does not help diagnose carpal tunnel syndrome. These findings should be interpreted cautiously, because diagnostic accuracy might have been distorted by the investigators' definitions of a positive ULNT. Furthermore, patients with PNP who presented with increased nerve mechanosensitivity rather than conduction loss might have been incorrectly classified by electrophysiological reference standards as not having PNP. The only evidence for concurrent validity of the ulnar nerve test was a case study on cubital tunnel syndrome. We recommend that researchers develop more comprehensive reference standards for PNP to accurately assess the concurrent validity of ULNTs and continue investigating the predictive validity of ULNTs for prognosis or treatment response.

  8. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    Science.gov (United States)

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  9. Validation of a clinical critical thinking skills test in nursing

    Directory of Open Access Journals (Sweden)

    Sujin Shin

    2015-01-01

    Full Text Available Purpose: The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS and to subsequently validate its performance. Methods: This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Results: Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. Conclusion: From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability.

  10. Alternatives to animal testing: research, trends, validation, regulatory acceptance.

    Science.gov (United States)

    Huggins, Jane

    2003-01-01

    Current trends and issues in the development of alternatives to the use of animals in biomedical experimentation are discussed in this position paper. Eight topics are considered and include refinement of acute toxicity assays; eye corrosion/irritation alternatives; skin corrosion/irritation alternatives; contact sensitization alternatives; developmental/reproductive testing alternatives; genetic engineering (transgenic) assays; toxicogenomics; and validation of alternative methods. The discussion of refinement of acute toxicity assays is focused primarily on developments with regard to reduction of the number of animals used in the LD(50) assay. However, the substitution of humane endpoints such as clinical signs of toxicity for lethality in these assays is also evaluated. Alternative assays for eye corrosion/irritation as well as those for skin corrosion/irritation are described with particular attention paid to the outcomes, both successful and unsuccessful, of several validation efforts. Alternative assays for contact sensitization and developmental/reproductive toxicity are presented as examples of methods designed for the examination of interactions between toxins and somewhat more complex physiological systems. Moreover, genetic engineering and toxicogenomics are discussed with an eye toward the future of biological experimentation in general. The implications of gene manipulation for research animals, specifically, are also examined. Finally, validation methods are investigated as to their effectiveness, or lack thereof, and suggestions for their standardization and improvement, as well as implementation are reviewed.

  11. Diversity and testing requirements of programmable automation systems; Ohjelmoitavan automaation diversiteetti- ja testausvaatimukset

    Energy Technology Data Exchange (ETDEWEB)

    Haapanen, P.; Maskuniitty, M.

    1993-04-01

    In the report programmable digital operation and safety automation systems for nuclear power plants are discussed. The programmable systems deviate by their properties and behaviour from the conventional non-programmable systems in such extent, that their verification and validation for safety critical applications requires new methods and practices. The safety assessment can not be based on conventional probabilistic methods due to the difficulties in the quantification of the reliability of the software and hardware. A safety critical programmable system shall include diverse redundant parts so that no residual program fault can not cause the failure of the intended function of the system. Although complete testing of a programmable system is impossible, different tests have a central role in the production and validation process of the system. Diversity is important also in confidence building measures for the implemented system. Independent analysis and testing of the system should use different methods and tools from those used in the production and validation process by the system vendor. Use of diversity and testing are concluded to be central issues in producing safe programmable system and in proving them to be safe enough. By combining functional and programming diversity in a suitable way one can produce a system that is safe enough without having a non-programmable back-up system. (48 refs., 10 figs., 2 tabs.).

  12. Verification and Validation in Systems Engineering

    CERN Document Server

    Debbabi, Mourad; Jarraya, Yosr; Soeanu, Andrei; Alawneh, Luay

    2010-01-01

    "Verification and validation" represents an important process used for the quality assessment of engineered systems and their compliance with the requirements established at the beginning of or during the development cycle. Debbabi and his coauthors investigate methodologies and techniques that can be employed for the automatic verification and validation of systems engineering design models expressed in standardized modeling languages. Their presentation includes a bird's eye view of the most prominent modeling languages for software and systems engineering, namely the Unified Model

  13. VALGALI: VERIFICATION AND VALIDATION TOOL FOR THE LIBRARIES PRODUCED BY THE GALILEE SYSTEM

    International Nuclear Information System (INIS)

    Mengelle, S.

    2011-01-01

    Full text: In this paper we present VALGALI the verification and validation tool for the libraries produced by the nuclear data processing system GALILEE. The aim of this system is to provide libraries with consistent physical data for various application codes (the deterministic transport code APOLLO2, the Monte Carlo transport code TRRIPOLI-4, the depletion code DARWIN, ...). For each library, are the data stored at the good place with the good format and so one. Are the libraries used by the various codes consistent. What is the physical quality of the cross sections and data present in the libraries. These three types of tests correspond to the classic stages of VandV. The great strength of VALGALI is to be generic and not dedicated to one application code Consequently, it is based on a common physical validation database which coverage is regularly increased. For all these test cases, the input data are declined for each relevant application code Moreover it can exist specific test case for each application code: At the present, VALGALI an check and validate the libraries of APOLLO2 and TRIPOLI4, but in the near future VALGALI wil also treat the libraries of DARWIN.

  14. 40 CFR 1045.501 - How do I run a valid emission test?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false How do I run a valid emission test... Procedures § 1045.501 How do I run a valid emission test? (a) Applicability. This subpart is addressed to you... maximum test speed. (g) Special and alternate procedures. If you are unable to run the duty cycle...

  15. 40 CFR 1054.501 - How do I run a valid emission test?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false How do I run a valid emission test... Procedures § 1054.501 How do I run a valid emission test? (a) Applicability. This subpart is addressed to you... provisions of 40 CFR 1065.405 describes how to prepare an engine for testing. However, you may consider...

  16. The validation of an infrared simulation system

    CSIR Research Space (South Africa)

    De Waal, A

    2013-08-01

    Full Text Available theoretical validation framework. This paper briefly describes the procedure used to validate software models in an infrared system simulation, and provides application examples of this process. The discussion includes practical validation techniques...

  17. Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability.

    Science.gov (United States)

    Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa

    2016-04-01

    Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.

  18. The Space Technology-7 Disturbance Reduction System Precision Control Flight Validation Experiment Control System Design

    Science.gov (United States)

    O'Donnell, James R.; Hsu, Oscar C.; Maghami, Peirman G.; Markley, F. Landis

    2006-01-01

    As originally proposed, the Space Technology-7 Disturbance Reduction System (DRS) project, managed out of the Jet Propulsion Laboratory, was designed to validate technologies required for future missions such as the Laser Interferometer Space Antenna (LISA). The two technologies to be demonstrated by DRS were Gravitational Reference Sensors (GRSs) and Colloidal MicroNewton Thrusters (CMNTs). Control algorithms being designed by the Dynamic Control System (DCS) team at the Goddard Space Flight Center would control the spacecraft so that it flew about a freely-floating GRS test mass, keeping it centered within its housing. For programmatic reasons, the GRSs were descoped from DRS. The primary goals of the new mission are to validate the performance of the CMNTs and to demonstrate precise spacecraft position control. DRS will fly as a part of the European Space Agency (ESA) LISA Pathfinder (LPF) spacecraft along with a similar ESA experiment, the LISA Technology Package (LTP). With no GRS, the DCS attitude and drag-free control systems make use of the sensor being developed by ESA as a part of the LTP. The control system is designed to maintain the spacecraft s position with respect to the test mass, to within 10 nm/the square root of Hz over the DRS science frequency band of 1 to 30 mHz.

  19. Implementation of the validation testing in MPPG 5.a "Commissioning and QA of treatment planning dose calculations-megavoltage photon and electron beams".

    Science.gov (United States)

    Jacqmin, Dustin J; Bredfeldt, Jeremy S; Frigo, Sean P; Smilowitz, Jennifer B

    2017-01-01

    The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analysis tools to deliver and analyze the validation tests. This included the development of a novel, open-source software tool to compare scanning water tank measurements to 3D DICOM-RT Dose distributions. Dose calculation algorithms in both Pinnacle and Eclipse were tested with MPPG 5.a to validate the modeling of Varian TrueBeam linear accelerators. The validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (TPS). Overall, the validation testing recommended in MPPG 5.a took approximately 79 person-hours for a machine with four photon and five electron energies for a single TPS. Of the 79 person-hours, 26 person-hours required time on the machine, and the remainder involved preparation and analysis. The basic photon, electron, and heterogeneity correction tests were evaluated with the tolerances in MPPG 5.a, and the tolerances were met for all tests. The MPPG 5.a evaluation criteria were used to assess the small field and IMRT/VMAT validation tests. Both institutions found the use of MPPG 5.a to be a valuable resource during the commissioning process. The validation testing in MPPG 5.a showed the strengths and limitations of the TPS models. In addition, the data collected during the validation testing is useful for routine QA of the TPS, validation of software upgrades, and commissioning of new algorithms. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of

  20. Validation of the Arabic Version of the Internet Gaming Disorder-20 Test.

    Science.gov (United States)

    Hawi, Nazir S; Samaha, Maya

    2017-04-01

    In recent years, researchers have been trying to shed light on gaming addiction and its association with different psychiatric disorders and psychological determinants. The latest edition version of the American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) included in its Section 3 Internet Gaming Disorder (IGD) as a condition for further empirical study and proposed nine criteria for the diagnosis of IGD. The 20-item Internet Gaming Disorder (IGD-20) Test was developed as a valid and reliable tool to assess gaming addiction based on the nine criteria set by the DSM-5. The aim of this study is to validate an Arabic version of the IGD-20 Test. The Arabic version of IGD-20 will not only help in identifying Arabic-speaking pathological gamers but also stimulate cross-cultural studies that could contribute to an area in need of more research for insight and treatment. After a process of translation and back-translation and with the participation of a sizable sample of Arabic-speaking adolescents, the present study conducted a psychometric validation of the IGD-20 Test. Our confirmatory factor analysis showed the validity of the Arabic version of the IGD-20 Test. The one-factor model of the Arabic IGD-20 Test had very good psychometric properties, and it fitted the sample data extremely well. In addition, correlation analysis between the IGD-20 Test and the daily duration on weekdays and weekends gameplay revealed significant positive relationships that warranted a criterion-related validation. Thus, the Arabic version of the IGD-20 Test is a valid and reliable measure of IGD among Arabic-speaking populations.

  1. Point-to-Point! Validation of the Small Aircraft Transportation System Higher Volume Operations Concept

    Science.gov (United States)

    Williams, Daniel M.

    2006-01-01

    Described is the research process that NASA researchers used to validate the Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) concept. The four phase building-block validation and verification process included multiple elements ranging from formal analysis of HVO procedures to flight test, to full-system architecture prototype that was successfully shown to the public at the June 2005 SATS Technical Demonstration in Danville, VA. Presented are significant results of each of the four research phases that extend early results presented at ICAS 2004. HVO study results have been incorporated into the development of the Next Generation Air Transportation System (NGATS) vision and offer a validated concept to provide a significant portion of the 3X capacity improvement sought after in the United States National Airspace System (NAS).

  2. Incremental Validity of Test Session and Classroom Observations in a Multimethod Assessment of Attention Deficit/Hyperactivity Disorder

    Science.gov (United States)

    McConaughy, Stephanie H.; Harder, Valerie S.; Antshel, Kevin M.; Gordon, Michael; Eiraldi, Ricardo; Dumenci, Levent

    2010-01-01

    This study tested the incremental validity of behavioral observations, over and above parent and teacher reports, for assessing symptoms of Attention Deficit/Hyperactivity Disorder (ADHD) in children ages 6 to 12, using the Test Observation Form (TOF) and Direct Observation Form (DOF) from the Achenbach System of Empirically Based Assessment. The…

  3. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    Science.gov (United States)

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  4. Using Frankencerts for Automated Adversarial Testing of Certificate Validation in SSL/TLS Implementations.

    Science.gov (United States)

    Brubaker, Chad; Jana, Suman; Ray, Baishakhi; Khurshid, Sarfraz; Shmatikov, Vitaly

    2014-01-01

    Modern network security rests on the Secure Sockets Layer (SSL) and Transport Layer Security (TLS) protocols. Distributed systems, mobile and desktop applications, embedded devices, and all of secure Web rely on SSL/TLS for protection against network attacks. This protection critically depends on whether SSL/TLS clients correctly validate X.509 certificates presented by servers during the SSL/TLS handshake protocol. We design, implement, and apply the first methodology for large-scale testing of certificate validation logic in SSL/TLS implementations. Our first ingredient is "frankencerts," synthetic certificates that are randomly mutated from parts of real certificates and thus include unusual combinations of extensions and constraints. Our second ingredient is differential testing: if one SSL/TLS implementation accepts a certificate while another rejects the same certificate, we use the discrepancy as an oracle for finding flaws in individual implementations. Differential testing with frankencerts uncovered 208 discrepancies between popular SSL/TLS implementations such as OpenSSL, NSS, CyaSSL, GnuTLS, PolarSSL, MatrixSSL, etc. Many of them are caused by serious security vulnerabilities. For example, any server with a valid X.509 version 1 certificate can act as a rogue certificate authority and issue fake certificates for any domain, enabling man-in-the-middle attacks against MatrixSSL and GnuTLS. Several implementations also accept certificate authorities created by unauthorized issuers, as well as certificates not intended for server authentication. We also found serious vulnerabilities in how users are warned about certificate validation errors. When presented with an expired, self-signed certificate, NSS, Safari, and Chrome (on Linux) report that the certificate has expired-a low-risk, often ignored error-but not that the connection is insecure against a man-in-the-middle attack. These results demonstrate that automated adversarial testing with frankencerts

  5. Test of Flow Characteristics in Tubular Fuel Assembly I - Establishment of test loop and measurement validation test

    International Nuclear Information System (INIS)

    Park, Jong Hark; Chae, H. T.; Park, C.; Kim, H.

    2005-12-01

    Tubular type fuel has been developed as one of candidates for Advanced HANARO Reactor(AHR). It is necessary to test the flow characteristics such as velocity in each flow channels and pressure drop of tubular type fuel. A hydraulic test-loop to examine the hydraulic characteristics for a tubular type fuel has been designed and constructed. It consists of three parts; a) piping-loop including pump and motor, magnetic flow meter and valves etc, b) test-section part where a simulated tubular type fuel is located, and 3) data acquisition system to get reading signals from sensors or instruments. In this report, considerations during the design and installation of the facility and the selection of data acquisition sensors and instruments are described in detail. Before doing the experiment to measure the flow velocities in flow channels, a preliminary tests have been done for measuring the coolant velocities using pitot-tube and for validating the measurement accuracy as well. Local velocities of the radial direction in circular tubes are measured at regular intervals of 60 degrees by three pitot-tubes. Flow rate inside the circular flow channel can be obtained by integrating the velocity distribution in radial direction. The measured flow rate was compared to that of magnetic flow meter. According to the results, two values had a good agreement, which means that the measurement of coolant velocity by using pitot-tube and the flow rate measured by the magnetic flow meter are reliable. Uncertainty analysis showed that the error of velocity measurement by pitot-tube is less than ±2.21%. The hydraulic test-loop also can be adapted to others such as HANARO 18 and 36 fuel, in-pile system of FTL(Fuel Test Loop), etc

  6. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    Science.gov (United States)

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  7. Content validity and reliability of test of gross motor development in Chilean children

    Directory of Open Access Journals (Sweden)

    Marcelo Cano-Cappellacci

    2015-01-01

    Full Text Available ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2 for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.

  8. Cross-Cultural Validation of TEMAS, a Minority Projective Test.

    Science.gov (United States)

    Costantino, Giuseppe; And Others

    The theoretical framework and cross-cultural validation of Tell-Me-A-Story (TEMAS), a projective test developed to measure personality development in ethnic minority children, is presented. The TEMAS test consists of 23 chromatic pictures which incorporate the following characteristics: (1) representation of antithetical concepts which the…

  9. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests.

    Science.gov (United States)

    Rijken, Noortje H; van Engelen, Baziel G; Weerdesteyn, Vivian; Geurts, Alexander C

    2015-12-01

    To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). Case-control study. University medical center. Patients with various severity levels of FSHD (n=9) and healthy control subjects (n=10) were included (N=19). Not applicable. A 4-point ordinal scale was designed to grade performance on the following 4 antigravity tests: sit to stance, stance to sit, step up, and step down. In addition, the 6-minute walk test, 10-m walking test, Berg Balance Scale, and timed Up and Go test were administered as conventional tests. Construct validity was determined by linear regression analysis using the Clinical Severity Score (CSS) as the dependent variable. Interrater agreement was tested using a κ analysis. Patients with FSHD performed worse on all 4 antigravity tests compared with the controls. Stronger correlations were found within than between test categories (antigravity vs conventional). The antigravity tests revealed the highest explained variance with regard to the CSS (R(2)=.86, P=.014). Interrater agreement was generally good. The results of this exploratory study support the construct validity and interrater reliability of the proposed antigravity tests for the assessment of functional capacity in patients with FSHD taking into account the use of compensatory strategies. Future research should further validate these results in a larger sample of patients with FSHD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Geant4 hadronic and electromagnetic validation tests in LHCb

    CERN Document Server

    Griffith, Peter Noel

    2016-01-01

    LHCb uses Geant4 to simulate the interactions of particles with the detector material and components. The simulation response can vary significantly due to modification of material description, of detector geometry, or of the Geant4 toolkit itself. Therefore, an extensive variety of tools have been developed to study the effects of Geant4 modification on the LHCb simulation framework and on stand-alone environments within the LHCb software infrastructure. These tools have proven to be very effective for investigating new and alternative models provided by Geant4, and also in identifying and fixing anomalous behaviours that arise from changes. The next goal is to have these validation tests run autonomously and periodically, alerting the relevant users when problems are detected. Quick and easy comparison of the results from different software versions and simulation models will be made possible through the web interface of the LHCb Performance and Regression testing system, LHCbPR.

  11. Contribution of the JRC to test and validate innovation systems for earthquake protection and control of vibration of structures

    International Nuclear Information System (INIS)

    Renda, Vito

    2002-01-01

    The mission of JRC is to provide scientific and technical support for the conception, development and monitoring of EU policies. The task of IPSC is to provide cyber-security and fight against the fraud; natural, technological and economic risks; humanitarian security, non-proliferation and nuclear safeguards. The Structural mechanics laboratory supplies pseudo-dynamic testing of full/large scale models and structures. Earthquake simulation is provided by two complementary approaches: shaking table, and reaction wall. The main objectives of the large scale testing are: to calibrate analytical models suitable for different classes of structures; to validate rules of norms and standards; and to contribute to the development of innovative technologies for the protection of structures of both civil and architectural interest. Seismic isolation program deals with validation of the pseudo-dynamic method for testing large models of base isolated structures

  12. Validation of a laboratory and hospital information system in a medical laboratory accredited according to ISO 15189.

    Science.gov (United States)

    Biljak, Vanja Radisic; Ozvald, Ivan; Radeljak, Andrea; Majdenic, Kresimir; Lasic, Branka; Siftar, Zoran; Lovrencic, Marijana Vucic; Flegar-Mestric, Zlata

    2012-01-01

    The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia. Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%). The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%. We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose.

  13. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  14. Reliability and Validity of the Inline Skating Skill Test

    Science.gov (United States)

    Radman, Ivan; Ruzic, Lana; Padovan, Viktoria; Cigrovski, Vjekoslav; Podnar, Hrvoje

    2016-01-01

    This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male) were randomized into two groups (competitive level vs. recreational level). They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]). In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%]) and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]). The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2) revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters. Key points Study evaluated the reliability and construct validity of a newly developed inline skating skill test. Evaluated test is a first protocol designed to assess specific inline skating skill. Two groups of amateur skaters with different skating proficiency repeated the skill test in four separate occasions. The results suggest that evaluated test is reliable and valid to evaluate inline skating skill in amateur skaters. PMID:27803616

  15. Utilisation of real-scale renewable energy test facility for validation of generic wind turbine and wind power plant controller models

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Gevorgian, Vahan; Wallen, Robb

    2016-01-01

    This article presents an example of application of a modern test facility conceived for experiments regarding the integration of renewable energy in the power system. The capabilities of the test facility are used to validate dynamic simulation models of wind power plants and their controllers....... The models are based on standard and generic blocks. The successful validation of events related to the control of active power (control phenomena in...

  16. Development and validation of a partial life-cycle test with Potamopyrgus antipodarum

    DEFF Research Database (Denmark)

    Geiss, Cornelia; Holbech, Henrik; Kinnberg, Karin Lund

    endpoints. The present study aims to develop and validate the partial life-cycle test on the reproduction of P. antipodarum. Here, results from two pre-validation studies of the reproduction test with the chemicals tributyltin (TBT) with nominal concentrations of 10 - 400 ng TBT-Sn/L and cadmium...

  17. Test your memory-Turkish version (TYM-TR): reliability and validity study of a cognitive screening test.

    Science.gov (United States)

    Maviş, Ilknur; Özbabalik Adapinar, Belgin Demet; Yenilmez, Çinar; Aydin, Ayşe; Olgun, Engin; Bal, Cengiz

    2015-01-01

    The test your memory (TYM) is reported to be a sensitive cognitive function assessment scale for people with dementia. The aim of the present study was to investigate the reliability and validity of an adapted Turkish version of the TYM (TYM-TR) among Turkish dementia patients. The TYM-TR was given to 59 patients with dementia aged 60+ and 336 normal controls aged 23-75+. The diagnostic utility of the TYM-TR was compared with that of the mini-mental state examination (MMSE) to validate it. The internal consistency of the TYM-TR was a = 0.85. The test-retest reliability was 0.97 (P reliability and validity to distinguish dementia in the Turkish population.

  18. Urine specimen validity test for drug abuse testing in workplace and court settings.

    Science.gov (United States)

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  19. Known-Groups and Concurrent Validity of the Mandarin Tone Identification Test (MTIT.

    Directory of Open Access Journals (Sweden)

    Shufeng Zhu

    Full Text Available The Mandarin Tone Identification Test (MTIT is a new test designed to assess the tone identification abilities of children with hearing impairment (HI. Evidence for reliability and sensitivity has been reported. The present study aimed to evaluate the known-groups and concurrent validity of the MTIT.The MTIT and Mandarin Pediatric Speech Intelligibility test (MPSI were administered in quiet and in noise conditions. The known-groups validity was evaluated by comparing the performance of the MTIT on children with two different levels of HI. The MPSI was included to evaluate the concurrent validity of the MTIT.81 children with HI were recruited in the present study. They were Mandarin-speaking children with profound HI (mean age = 9; 0, n = 41 and with moderate to severe HI (mean age = 8; 9, n = 40.Scores on the MTIT differed between the two groups with different hearing levels suggesting good known-groups validity. A strong relationship between tone and sentence perception both in quiet and in noise provided preliminary evidence for concurrent validity.The present study confirmed that the MTIT has good known-groups validity and provided preliminary evidence for concurrent validity. The MTIT could be used to evaluate tone identification ability in children with HI with confidence.

  20. Validation of Linguistic and Communicative Oral Language Tests for Spanish-English Bilingual Programs.

    Science.gov (United States)

    Politzer, Robert L.; And Others

    1983-01-01

    The development, administration, and scoring of a communicative test and its validation with tests of linguistic and sociolinguistic competence in English and Spanish are reported. Correlation with measures of home language use and school achievement are also presented, and issues of test validation for bilingual programs are discussed. (MSE)

  1. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-11-01

    Full Text Available Reasoning with Inductive Argument Test:A Study of Validity and Reliability Objective: The aim of our study is to research reliability and validity and to evaluate the usability of Turkish version of Reasoning with Inductive Argument Test (RIAT in Turkish healty population. Method: 51 healty volunteers who work in Ankara Dıskapi Yildirim Beyazit Research and Training Hospital participated in this study. Reasoning with Inductive Argument Test (RIAT was translated into Turkish by three clinical good knowledge of English. Participants were given a sociodemographic data form, and RIAT were performed by clinicians. To test the reliability of the Turkish version of RIAT, Cronbach’s alpha coefficient was calculated and the halving method was used for the test. Results: The internal consistency of the Reasoning with Inductive Argument Test (RIAT items, Cronbach’s alpha internal consistency coefficient measurements of 0.73 was found to be statistically significant. Spearman-Brown coefficient that determines the reliability of the whole test r=0.74 was found. Kurtosis values of all the items was below 1.5 and the percentages in the second evaluation were mainly lower. At the same time, both change in belief between self produced RIAT options and given RIAT options (p=0.02, z=-2296 as well as changes in beliefs between related and unrelated items for Obsessive Compulsive Disorder (OCD difference (p=0.03, z=-2.199 were significant. Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population.

  2. Development and psychometric validation of the verbal affective memory test

    DEFF Research Database (Denmark)

    Jensen, Christian Gaden; Hjordt, Liv V; Stenbæk, Dea S

    2015-01-01

    . Furthermore, larger seasonal decreases in positive recall significantly predicted larger increases in depressive symptoms. Retest reliability was satisfactory, rs ≥ .77. In conclusion, VAMT-24 is more thoroughly developed and validated than existing verbal affective memory tests and showed satisfactory...... psychometric properties. VAMT-24 seems especially sensitive to measuring positive verbal recall bias, perhaps due to the application of common, non-taboo words. Based on the psychometric and clinical results, we recommend VAMT-24 for international translations and studies of affective memory.......We here present the development and validation of the Verbal Affective Memory Test-24 (VAMT-24). First, we ensured face validity by selecting 24 words reliably perceived as positive, negative or neutral, respectively, according to healthy Danish adults' valence ratings of 210 common and non...

  3. Development, verification and validation of an FPGA-based core heat removal protection system for a PWR

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Yichun, E-mail: ycwu@xmu.edu.cn [College of Energy, Xiamen University, Xiamen 361102 (China); Shui, Xuanxuan, E-mail: 807001564@qq.com [College of Energy, Xiamen University, Xiamen 361102 (China); Cai, Yuanfeng, E-mail: 1056303902@qq.com [College of Energy, Xiamen University, Xiamen 361102 (China); Zhou, Junyi, E-mail: 1032133755@qq.com [College of Energy, Xiamen University, Xiamen 361102 (China); Wu, Zhiqiang, E-mail: npic_wu@126.com [State Key Laboratory of Reactor System Design Technology, Nuclear Power Institute of China, Chengdu 610041 (China); Zheng, Jianxiang, E-mail: zwu@xmu.edu.cn [College of Energy, Xiamen University, Xiamen 361102 (China)

    2016-05-15

    Highlights: • An example on life cycle development process and V&V on FPGA-based I&C is presented. • Software standards and guidelines are used in FPGA-based NPP I&C system logic V&V. • Diversified FPGA design and verification languages and tools are utilized. • An NPP operation principle simulator is used to simulate operation scenarios. - Abstract: To reach high confidence and ensure reliability of nuclear FPGA-based safety system, life cycle processes of discipline specification and implementation of design as well as regulations verification and validation (V&V) are needed. A specific example on how to conduct life cycle development process and V&V on FPGA-based core heat removal (CHR) protection system for CPR1000 pressure water reactor (PWR) is presented in this paper. Using the existing standards and guidelines for life cycle development and V&V, a simplified FPGA-based CHR protection system for PWR has been designed, implemented, verified and validated. Diversified verification and simulation languages and tools are used by the independent design team and the V&V team. In the system acceptance testing V&V phase, a CPR1000 NPP operation principle simulator (OPS) model is utilized to simulate normal and abnormal operation scenarios, and provide input data to the under-test FPGA-based CHR protection system and a verified C code CHR function module. The evaluation results are applied to validate the under-test FPGA-based CHR protection system. The OPS model operation outputs also provide reasonable references for the tests. Using an OPS model in the system acceptance testing V&V is cost-effective and high-efficient. A dedicated OPS, as a commercial-off-the-shelf (COTS) item, would contribute as an important tool in the V&V process of NPP I&C systems, including FPGA-based and microprocessor-based systems.

  4. The Development and Validation of the Student Response System Benefit Scale

    Science.gov (United States)

    Hooker, J. F.; Denker, K. J.; Summers, M. E.; Parker, M.

    2016-01-01

    Previous research into the benefits student response systems (SRS) that have been brought into the classroom revealed that SRS can contribute positively to student experiences. However, while the benefits of SRS have been conceptualized and operationalized into a widely cited scale, the validity of this scale had not been tested. Furthermore,…

  5. Brief implicit association test: Validity and utility in prediction of voting behavior

    Directory of Open Access Journals (Sweden)

    Pavlović Maša D.

    2013-01-01

    Full Text Available We employed the Brief Implicit Association Test (a recently developed short version of IAT to measure implicit political attitudes toward four political parties running for Serbian parliament. To test its criterion validity, we measured voting intention and actual voting behavior. In addition, we introduced political involvement as a potential moderator of the BIAT’s predictive and incremental validity. The BIAT demonstrated good internal and predictive validity, but lacked incremental validity over self-report measures. Predictive power of the BIAT was moderated by political involvement - the BIAT scores were stronger predictors of voting intention and behavior among voters highly involved in politics. [Projekat Ministarstva nauke Republike Srbije, br. 179018

  6. Validation of human factor engineering integrated system

    International Nuclear Information System (INIS)

    Fang Zhou

    2013-01-01

    Apart from hundreds of thousands of human-machine interface resources, the control room of a nuclear power plant is a complex system integrated with many factors such as procedures, operators, environment, organization and management. In the design stage, these factors are considered by different organizations separately. However, whether above factors could corporate with each other well in operation and whether they have good human factors engineering (HFE) design to avoid human error, should be answered in validation of the HFE integrated system before delivery of the plant. This paper addresses the research and implementation of the ISV technology based on case study. After introduction of the background, process and methodology of ISV, the results of the test are discussed. At last, lessons learned from this research are summarized. (authors)

  7. Directed Design of Experiments for Validating Probability of Detection Capability of NDE Systems (DOEPOD)

    Science.gov (United States)

    Generazio, Edward R.

    2015-01-01

    Directed Design of Experiments for Validating Probability of Detection Capability of NDE Systems (DOEPOD) Manual v.1.2 The capability of an inspection system is established by applications of various methodologies to determine the probability of detection (POD). One accepted metric of an adequate inspection system is that there is 95% confidence that the POD is greater than 90% (90/95 POD). Design of experiments for validating probability of detection capability of nondestructive evaluation (NDE) systems (DOEPOD) is a methodology that is implemented via software to serve as a diagnostic tool providing detailed analysis of POD test data, guidance on establishing data distribution requirements, and resolving test issues. DOEPOD demands utilization of observance of occurrences. The DOEPOD capability has been developed to provide an efficient and accurate methodology that yields observed POD and confidence bounds for both Hit-Miss or signal amplitude testing. DOEPOD does not assume prescribed POD logarithmic or similar functions with assumed adequacy over a wide range of flaw sizes and inspection system technologies, so that multi-parameter curve fitting or model optimization approaches to generate a POD curve are not required. DOEPOD applications for supporting inspector qualifications is included.

  8. Evaluating the Predictive Validity of Graduate Management Admission Test Scores

    Science.gov (United States)

    Sireci, Stephen G.; Talento-Miller, Eileen

    2006-01-01

    Admissions data and first-year grade point average (GPA) data from 11 graduate management schools were analyzed to evaluate the predictive validity of Graduate Management Admission Test[R] (GMAT[R]) scores and the extent to which predictive validity held across sex and race/ethnicity. The results indicated GMAT verbal and quantitative scores had…

  9. Measurement of Dietary Restraint: Validity Tests of Four Questionnaires

    Science.gov (United States)

    Williamson, Donald A.; Martin, Corby K.; York-Crowe, Emily; Anton, Stephen D.; Redman, Leanne M.; Han, Hongmei; Ravussin, Eric

    2007-01-01

    This study tested the validity of four measures of dietary restraint: Dutch Eating Behavior Questionnaire, Eating Inventory (EI), Revised Restraint Scale (RS), and the Current Dieting Questionnaire. Dietary restraint has been implicated as a determinant of overeating and binge eating. Conflicting findings have been attributed to different methods for measuring dietary restraint. The validity of four self-report measures of dietary restraint and dieting behavior was tested using: 1) factor analysis, 2) changes in dietary restraint in a randomized controlled trial of different methods to achieve calorie restriction, and 3) correlation of changes in dietary restraint with an objective measure of energy balance, calculated from the changes in fat mass and fat-free mass over a six-month dietary intervention. Scores from all four questionnaires, measured at baseline, formed a dietary restraint factor, but the RS also loaded on a binge eating factor. Based on change scores, the EI Restraint scale was the only measure that correlated significantly with energy balance expressed as a percentage of energy require d for weight maintenance. These findings suggest that that, of the four questionnaires tested, the EI Restraint scale was the most valid measure of the intent to diet and actual caloric restriction. PMID:17101191

  10. Concurrent and discriminant validity of the Star Excursion Balance Test for military personnel with lateral ankle sprain.

    Science.gov (United States)

    Bastien, Maude; Moffet, Hélène; Bouyer, Laurent; Perron, Marc; Hébert, Luc J; Leblond, Jean

    2014-02-01

    The Star Excursion Balance Test (SEBT) has frequently been used to measure motor control and residual functional deficits at different stages of recovery from lateral ankle sprain (LAS) in various populations. However, the validity of the measure used to characterize performance--the maximal reach distance (MRD) measured by visual estimation--is still unknown. To evaluate the concurrent validity of the MRD in the SEBT estimated visually vs the MRD measured with a 3D motion-capture system and evaluate and compare the discriminant validity of 2 MRD-normalization methods (by height or by lower-limb length) in participants with or without LAS (n = 10 per group). There is a high concurrent validity and a good degree of accuracy between the visual estimation measurement and the MRD gold-standard measurement for both groups and under all conditions. The Cohen d ratios between groups and MANOVA products were higher when computed from MRD data normalized by height. The results support the concurrent validity of visual estimation of the MRD and the use of the SEBT to evaluate motor control. Moreover, normalization of MRD data by height appears to increase the discriminant validity of this test.

  11. Evolution of the JPSS Ground Project Calibration and Validation System

    Science.gov (United States)

    Purcell, Patrick; Chander, Gyanesh; Jain, Peyush

    2016-01-01

    The Joint Polar Satellite System (JPSS) is the National Oceanic and Atmospheric Administration's (NOAA) next-generation operational Earth observation Program that acquires and distributes global environmental data from multiple polar-orbiting satellites. The JPSS Program plays a critical role to NOAA's mission to understand and predict changes in weather, climate, oceans, coasts, and space environments, which supports the Nation's economy and protection of lives and property. The National Aeronautics and Space Administration (NASA) is acquiring and implementing the JPSS, comprised of flight and ground systems, on behalf of NOAA. The JPSS satellites are planned to fly in the afternoon orbit and will provide operational continuity of satellite-based observations and products for NOAA Polar-orbiting Operational Environmental Satellites (POES) and the Suomi National Polar-orbiting Partnership (SNPP) satellite. To support the JPSS Calibration and Validation (CalVal) node Government Resource for Algorithm Verification, Independent Test, and Evaluation (GRAVITE) services facilitate: Algorithm Integration and Checkout, Algorithm and Product Operational Tuning, Instrument Calibration, Product Validation, Algorithm Investigation, and Data Quality Support and Monitoring. GRAVITE is a mature, deployed system that currently supports the SNPP Mission and has been in operations since SNPP launch. This paper discusses the major re-architecture for Block 2.0 that incorporates SNPP lessons learned, architecture of the system, and demonstrates how GRAVITE has evolved as a system with increased performance. It is now a robust, stable, reliable, maintainable, scalable, and secure system that supports development, test, and production strings, replaces proprietary and custom software, uses open source software, and is compliant with NASA and NOAA standards.

  12. Validation of IEEE P1547.1 Interconnection Test Procedures: ASCO 7000 Soft Load Transfer System

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, B.; Englebretson, S.; Pink, C.; Daley, J.; Siciliano, R.; Hinton, D.

    2003-09-01

    This report presents the preliminary results of testing the ASCO 7000 Soft Load Transfer System according to IEEE P1547.1 procedures. The ASCO system interconnects synchronous generators with the electric power system and provides monitoring and control for the generator and grid connection through extensive protective functions. The purpose of this testing is to evaluate and give feedback on the contents of IEEE Draft Standard P1547.1 Conformance Tests Procedures for Equipment Interconnecting Distributed Resources With Electric Power Systems.

  13. 40 CFR 1039.501 - How do I run a valid emission test?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false How do I run a valid emission test? 1039.501 Section 1039.501 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Procedures § 1039.501 How do I run a valid emission test? (a) Use the equipment and procedures for...

  14. Predictive validity of the Biomedical Admissions Test: an evaluation and case study.

    Science.gov (United States)

    McManus, I C; Ferguson, Eamonn; Wakeford, Richard; Powis, David; James, David

    2011-01-01

    There has been an increase in the use of pre-admission selection tests for medicine. Such tests need to show good psychometric properties. Here, we use a paper by Emery and Bell [2009. The predictive validity of the Biomedical Admissions Test for pre-clinical examination performance. Med Educ 43:557-564] as a case study to evaluate and comment on the reporting of psychometric data in the field of medical student selection (and the comments apply to many papers in the field). We highlight pitfalls when reliability data are not presented, how simple zero-order associations can lead to inaccurate conclusions about the predictive validity of a test, and how biases need to be explored and reported. We show with BMAT that it is the knowledge part of the test which does all the predictive work. We show that without evidence of incremental validity it is difficult to assess the value of any selection tests for medicine.

  15. Tank monitor and control system (TMACS) revision 11 acceptance test procedure

    International Nuclear Information System (INIS)

    HOLM, M.J.

    1999-01-01

    The purpose of this document is to describe tests performed to validate Revision 11 of the Tank Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab

  16. Development of Flight-Test Performance Estimation Techniques for Small Unmanned Aerial Systems

    Science.gov (United States)

    McCrink, Matthew Henry

    This dissertation provides a flight-testing framework for assessing the performance of fixed-wing, small-scale unmanned aerial systems (sUAS) by leveraging sub-system models of components unique to these vehicles. The development of the sub-system models, and their links to broader impacts on sUAS performance, is the key contribution of this work. The sub-system modeling and analysis focuses on the vehicle's propulsion, navigation and guidance, and airframe components. Quantification of the uncertainty in the vehicle's power available and control states is essential for assessing the validity of both the methods and results obtained from flight-tests. Therefore, detailed propulsion and navigation system analyses are presented to validate the flight testing methodology. Propulsion system analysis required the development of an analytic model of the propeller in order to predict the power available over a range of flight conditions. The model is based on the blade element momentum (BEM) method. Additional corrections are added to the basic model in order to capture the Reynolds-dependent scale effects unique to sUAS. The model was experimentally validated using a ground based testing apparatus. The BEM predictions and experimental analysis allow for a parameterized model relating the electrical power, measurable during flight, to the power available required for vehicle performance analysis. Navigation system details are presented with a specific focus on the sensors used for state estimation, and the resulting uncertainty in vehicle state. Uncertainty quantification is provided by detailed calibration techniques validated using quasi-static and hardware-in-the-loop (HIL) ground based testing. The HIL methods introduced use a soft real-time flight simulator to provide inertial quality data for assessing overall system performance. Using this tool, the uncertainty in vehicle state estimation based on a range of sensors, and vehicle operational environments is

  17. Validation of new prognostic and predictive scores by sequential testing approach

    International Nuclear Information System (INIS)

    Nieder, Carsten; Haukland, Ellinor; Pawinski, Adam; Dalhaug, Astrid

    2010-01-01

    Background and Purpose: For practitioners, the question arises how their own patient population differs from that used in large-scale analyses resulting in new scores and nomograms and whether such tools actually are valid at a local level and thus can be implemented. A recent article proposed an easy-to-use method for the in-clinic validation of new prediction tools with a limited number of patients, a so-called sequential testing approach. The present study evaluates this approach in scores related to radiation oncology. Material and Methods: Three different scores were used, each predicting short overall survival after palliative radiotherapy (bone metastases, brain metastases, metastatic spinal cord compression). For each scenario, a limited number of consecutive patients entered the sequential testing approach. The positive predictive value (PPV) was used for validation of the respective score and it was required that the PPV exceeded 80%. Results: For two scores, validity in the own local patient population could be confirmed after entering 13 and 17 patients, respectively. For the third score, no decision could be reached even after increasing the sample size to 30. Conclusion: In-clinic validation of new predictive tools with sequential testing approach should be preferred over uncritical adoption of tools which provide no significant benefit to local patient populations. Often the necessary number of patients can be reached within reasonable time frames even in small oncology practices. In addition, validation is performed continuously as the data are collected. (orig.)

  18. Validation of new prognostic and predictive scores by sequential testing approach

    Energy Technology Data Exchange (ETDEWEB)

    Nieder, Carsten [Radiation Oncology Unit, Nordland Hospital, Bodo (Norway); Inst. of Clinical Medicine, Univ. of Tromso (Norway); Haukland, Ellinor; Pawinski, Adam; Dalhaug, Astrid [Radiation Oncology Unit, Nordland Hospital, Bodo (Norway)

    2010-03-15

    Background and Purpose: For practitioners, the question arises how their own patient population differs from that used in large-scale analyses resulting in new scores and nomograms and whether such tools actually are valid at a local level and thus can be implemented. A recent article proposed an easy-to-use method for the in-clinic validation of new prediction tools with a limited number of patients, a so-called sequential testing approach. The present study evaluates this approach in scores related to radiation oncology. Material and Methods: Three different scores were used, each predicting short overall survival after palliative radiotherapy (bone metastases, brain metastases, metastatic spinal cord compression). For each scenario, a limited number of consecutive patients entered the sequential testing approach. The positive predictive value (PPV) was used for validation of the respective score and it was required that the PPV exceeded 80%. Results: For two scores, validity in the own local patient population could be confirmed after entering 13 and 17 patients, respectively. For the third score, no decision could be reached even after increasing the sample size to 30. Conclusion: In-clinic validation of new predictive tools with sequential testing approach should be preferred over uncritical adoption of tools which provide no significant benefit to local patient populations. Often the necessary number of patients can be reached within reasonable time frames even in small oncology practices. In addition, validation is performed continuously as the data are collected. (orig.)

  19. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-12-01

    Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population. [JCBPR 2013; 2(3.000: 156-161

  20. Validation of AEGIS/SCOPE2 system through actual core follow calculations with irregular operational conditions

    International Nuclear Information System (INIS)

    Tabuchi, M.; Tatsumi, M.; Ohoka, Y.; Nagano, H.; Ishizaki, K.

    2017-01-01

    This paper describes overview of AEGIS/SCOPE2 system, an advanced in-core fuel management system for pressurized water reactors, and its validation results of actual core follow calculations including irregular operational conditions. AEGIS and SCOPE2 codes adopt more detailed and accurate calculation models compared to the current core design codes while computational cost is minimized with various techniques on numerical and computational algorithms. Verification and validation of AEGIS/SCOPE2 has been intensively performed to confirm validity of the system. As a part of the validation, core follow calculations have been carried out mainly for typical operational conditions. After the Fukushima Daiichi nuclear power plant accident, however, all the nuclear reactors in Japan suffered from long suspension and irregular operational conditions. In such situations, measured data in the restart and operation of the reactors should be good examinations for validation of the codes. Therefore, core follow calculations were carried out with AEGIS/SCOPE2 for various cases including zero power reactor physics tests with irregular operational conditions. Comparisons between measured data and predictions by AEGIS/SCOPE2 revealed the validity and robustness of the system. (author)

  1. Test of a small SDHW-system form the company Solahart Scandinavia ApS

    DEFF Research Database (Denmark)

    Andersen, Elsa

    1997-01-01

    The aim of the project is to verify the thermal performance of the tested SDHW system as well as to investigate whether changes in the system parameters or operation conditions will improve the thermal performance. The SDHW system is tested during a winter- and a sommerperiod. A validated computer...

  2. Validity of the Eating Attitudes Test and the Eating Disorders Inventory in Bulimia Nervosa.

    Science.gov (United States)

    Gross, Janet; And Others

    1986-01-01

    Assessed criterion and concurrent validity of the Eating Attitudes Test and the Eating Disorder Inventory in 82 women with bulimia nervosa. Both tests demonstrated criterion validity by discriminating bulimia nervosa subjects from normals. Only weak support was found for concurrent validity within bulimia subjects. Recommends combination of…

  3. Impact on participation and autonomy: test of validity and reliability for older persons

    Directory of Open Access Journals (Sweden)

    Isabelle Ottenvall Hammar

    2014-10-01

    Full Text Available In research and healthcare it is important to measure older persons’ self-determination in order to improve their possibilities to decide for themselves in daily life. The questionnaire Impact on Participation and Autonomy (IPA assesses self-determination, but is not constructed for older persons. The aim of this study was to examine the validity and reliability of the IPA-S questionnaire for persons aged 70 years and older. The study was performed in two steps; first a validity test of the Swedish version of the questionnaire, IPA-S, followed by a reliability test-retest of an adjusted version. The validity was tested with focus groups and individual interviews on persons aged 77-88 years, and the reliability on persons aged 70-99 years. The validity test result showed that IPA-S is valid for older persons but it was too extensive and the phrasing of the items needed adjustments. The reliability test-retest on the adjusted questionnaire, IPA-Older persons (IPA-O, showed that 15 of 22 items had high agreement. IPA-O can be used to measure older persons’ self-determination in their care and rehabilitation.

  4. Validation Test Report For The CRWMS Analysis and Logistics Visually Interactive Model Version 3.0, 10074-Vtr-3.0-00

    International Nuclear Information System (INIS)

    Gillespie, S.

    2000-01-01

    This report describes the tests performed to validate the CRWMS ''Analysis and Logistics Visually Interactive'' Model (CALVIN) Version 3.0 (V3.0) computer code (STN: 10074-3.0-00). To validate the code, a series of test cases was developed in the CALVIN V3.0 Validation Test Plan (CRWMS M and O 1999a) that exercises the principal calculation models and options of CALVIN V3.0. Twenty-five test cases were developed: 18 logistics test cases and 7 cost test cases. These cases test the features of CALVIN in a sequential manner, so that the validation of each test case is used to demonstrate the accuracy of the input to subsequent calculations. Where necessary, the test cases utilize reduced-size data tables to make the hand calculations used to verify the results more tractable, while still adequately testing the code's capabilities. Acceptance criteria, were established for the logistics and cost test cases in the Validation Test Plan (CRWMS M and O 1999a). The Logistics test cases were developed to test the following CALVIN calculation models: Spent nuclear fuel (SNF) and reactivity calculations; Options for altering reactor life; Adjustment of commercial SNF (CSNF) acceptance rates for fiscal year calculations and mid-year acceptance start; Fuel selection, transportation cask loading, and shipping to the Monitored Geologic Repository (MGR); Transportation cask shipping to and storage at an Interim Storage Facility (ISF); Reactor pool allocation options; and Disposal options at the MGR. Two types of cost test cases were developed: cases to validate the detailed transportation costs, and cases to validate the costs associated with the Civilian Radioactive Waste Management System (CRWMS) Management and Operating Contractor (M and O) and Regional Servicing Contractors (RSCs). For each test case, values calculated using Microsoft Excel 97 worksheets were compared to CALVIN V3.0 scenarios with the same input data and assumptions. All of the test case results compare with

  5. Validation of the German version of the Ford Insomnia Response to Stress Test.

    Science.gov (United States)

    Dieck, Arne; Helbig, Susanne; Drake, Christopher L; Backhaus, Jutta

    2018-06-01

    The purpose of this study was to assess the psychometric properties of a German version of the Ford Insomnia Response to Stress Test with groups with and without sleep problems. Three studies were analysed. Data set 1 was based on an initial screening for a sleep training program (n = 393), data set 2 was based on a study to test the test-retest reliability of the Ford Insomnia Response to Stress Test (n = 284) and data set 3 was based on a study to examine the influence of competitive sport on sleep (n = 37). Data sets 1 and 2 were used to test internal consistency, factor structure, convergent validity, discriminant validity and test-retest reliability of the Ford Insomnia Response to Stress Test. Content validity was tested using data set 3. Cronbach's alpha of the Ford Insomnia Response to Stress Test was good (α = 0.80) and test-retest reliability was satisfactory (r = 0.72). Overall, the one-factor model showed the best fit. Furthermore, significant positive correlations between the Ford Insomnia Response to Stress Test and impaired sleep quality, depression and stress reactivity were in line with the expectations regarding the convergent validity. Subjects with sleep problems had significantly higher scores in the Ford Insomnia Response to Stress Test than subjects without sleep problems (P Stress Test had significantly lower sleep quality (P = 0.01), demonstrating that vulnerability for stress-induced sleep disturbances accompanies poorer sleep quality in stressful episodes. The findings show that the German version of the Ford Insomnia Response to Stress Test is a reliable and valid questionnaire to assess the vulnerability to stress-induced sleep disturbances. © 2017 European Sleep Research Society.

  6. Scale Model Acoustic Test Validation of IOP-SS Water Prediction using Loci-STREAM-VoF

    Science.gov (United States)

    Nielsen, Tanner; West, Jeff

    2015-01-01

    The Scale Model Acoustic Test (SMAT) is a 5% scale test of the Space Launch System (SLS), which is currently being designed at Marshall Space Flight Center (MSFC). SMAT consists of a 5% scale representation of the ignition overpressure sound-suppression system (IOP-SS) that is being tested to quantify the water flow and induced air entrainment in and around the mobile launcher exhaust hole. This data will be compared with computational fluid dynamics (CFD) simulations using the newly developed Loci-STREAM Volume of Fluid (VoF) methods. Compressible and incompressible VoF methods have been formulated, and are currently being used to simulate the water flow of SMAT IOP-SS. The test data will be used to qualitatively and quantitatively assess and validate the VoF methods.

  7. Video game addiction test: validity and psychometric characteristics.

    NARCIS (Netherlands)

    Rooij, A.J. van; Schoenmakers, T.M.; Eijnden, R.J.J.M. van den; Vermulst, A.A.; Mheen, D. van de

    2012-01-01

    The study explores the reliability, validity, and measurement invariance of the Video game Addiction Test (VAT). Game-addiction problems are often linked to Internet enabled online games; the VAT has the unique benefit that it is theoretically and empirically linked to Internet addiction. The study

  8. Video Game Addiction Test: Validity and Psychometric Characteristics

    NARCIS (Netherlands)

    Rooij, A.J. van; Schoenmakers, T.M.; Eijnden, R.J.J.M. van den; Vermulst, A.A.; Mheen, H. van de

    2012-01-01

    The study explores the reliability, validity, and measurement invariance of the Video game Addiction Test (VAT). Game-addiction problems are often linked to Internet enabled online games; the VAT has the unique benefit that it is theoretically and empirically linked to Internet addiction. The study

  9. System verification and validation report for the TMAD code

    International Nuclear Information System (INIS)

    Finfrock, S.H.

    1995-01-01

    This document serves as the Verification and Validation Report for the TMAD code system, which includes the TMAD code and the LIBMAKR Code. The TMAD code was commissioned to facilitate the interpretation of moisture probe measurements in the Hanford Site waste tanks. In principle, the code is an interpolation routine that acts over a library of benchmark data based on two independent variables, typically anomaly size and moisture content. Two additional variables, anomaly type and detector type, can also be considered independent variables, but no interpolation is done over them. The dependent variable is detector response. The intent is to provide the code with measured detector responses from two or more detectors. The code will then interrogate (and interpolate upon) the benchmark data library and find the anomaly-type/anomaly-size/moisture-content combination that provides the closest match to the measured data. The primary purpose of this document is to provide the results of the system testing and the conclusions based thereon. The results of the testing process are documented in the body of the report. Appendix A gives the test plan, including test procedures, used in conducting the tests. Appendix B lists the input data required to conduct the tests, and Appendices C and 0 list the numerical results of the tests

  10. A realistic validation study of a new nitrogen multiple-breath washout system.

    Directory of Open Access Journals (Sweden)

    Florian Singer

    Full Text Available BACKGROUND: For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N(2MBW system. METHODS: The N(2MBW setup indirectly measures the N(2 fraction (F(N2 from main-stream carbon dioxide (CO(2 and side-stream oxygen (O(2 signals: F(N2 = 1-F(O2-F(CO2-F(Argon. For in vitro N(2MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and F(CO2. In vivo N(2MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N(2MBW outcome was functional residual capacity (FRC. We assessed in vitro error (√[difference](2 between measured and model FRC (100-4174 mL, and error between tests of in vivo FRC, lung clearance index (LCI, and normalized phase III slope indices (S(acin and S(cond. RESULTS: The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD error was 2.3 (1.7%. In 500 to 4174 mL FRCs, 121 (98% of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2%. LCI was the most reproducible ventilation inhomogeneity index. CONCLUSION: The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N(2MBW system reliably measures lung volumes and delivers reproducible LCI values.

  11. Development and validation status of the IFMIF High Flux Test Module

    International Nuclear Information System (INIS)

    Arbeiter, Frederik; Abou-Sena, Ali; Chen Yuming; Dolensky, Bernhard; Heupel, Tobias; Klein, Christine; Scheel, Nicola; Schlindwein, Georg

    2011-01-01

    The development of the IFMIF (International Fusion Material Irradiation Facility) High Flux Test Module in the EVEDA (Engineering Validation and Engineering Design Activities) phase up to 2013 includes conceptual design, engineering analyses, as well as design and engineering validation by building of prototypes and their testing. The High Flux Test Module is the device to facilitate the irradiation of SSTT samples of RAFM steels at temperatures 250-550 deg. C and up to an accumulated irradiation damage of 150 dpa. The requirements, the current design and the performance of the module are discussed, and the development process is outlined.

  12. Development and validation status of the IFMIF High Flux Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Arbeiter, Frederik, E-mail: frederik.arbeiter@kit.edu [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology (KIT-INR), Karlsruhe (Germany); Abou-Sena, Ali; Chen Yuming; Dolensky, Bernhard; Heupel, Tobias; Klein, Christine; Scheel, Nicola; Schlindwein, Georg [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology (KIT-INR), Karlsruhe (Germany)

    2011-10-15

    The development of the IFMIF (International Fusion Material Irradiation Facility) High Flux Test Module in the EVEDA (Engineering Validation and Engineering Design Activities) phase up to 2013 includes conceptual design, engineering analyses, as well as design and engineering validation by building of prototypes and their testing. The High Flux Test Module is the device to facilitate the irradiation of SSTT samples of RAFM steels at temperatures 250-550 deg. C and up to an accumulated irradiation damage of 150 dpa. The requirements, the current design and the performance of the module are discussed, and the development process is outlined.

  13. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan

    Directory of Open Access Journals (Sweden)

    Moore AL

    2018-02-01

    Full Text Available Amy Lawson Moore, Terissa M Miller Gibson Institute of Cognitive Research, Colorado Springs, CO, USA Purpose: The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills.Methods: This study included 2,737 participants aged 5–85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test–retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement.Results: Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test–retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93.Conclusion: The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan. Keywords: testing, cognitive skills, memory, processing speed, visual processing, auditory processing

  14. The validity of the Michigan Alcoholism Screening Test (MAST)

    DEFF Research Database (Denmark)

    Storgaard, H; Nielsen, S D; Gluud, C

    1994-01-01

    This review examines the validity of the Michigan Alcoholism Screening Test (MAST) as a screening instrument for alcohol problems. Studies that compare the MAST-questionnaire with other defined diagnostic criteria of alcohol problems were retrieved through MEDLINE and a cross-bibliographic check....... A total of 20 validity studies were included. The studies varied considerably regarding the prevalence of alcohol problems, the diagnostic criteria, and the examined patient categories. The MAST compared with other diagnostic criteria of alcohol problems gave validity measures with the following span...... and the specificities show substantial variations. The variables that seem to have the largest influence on the PVpos seem to be the prevalence of alcohol problems, the diagnostic method against which the MAST-questionnaire is validated, and the populations on which the MAST is applied. The MAST should in the future...

  15. The ad-libitum alcohol 'taste test': secondary analyses of potential confounds and construct validity.

    Science.gov (United States)

    Jones, Andrew; Button, Emily; Rose, Abigail K; Robinson, Eric; Christiansen, Paul; Di Lemma, Lisa; Field, Matt

    2016-03-01

    Motivation to drink alcohol can be measured in the laboratory using an ad-libitum 'taste test', in which participants rate the taste of alcoholic drinks whilst their intake is covertly monitored. Little is known about the construct validity of this paradigm. The objective of this study was to investigate variables that may compromise the validity of this paradigm and its construct validity. We re-analysed data from 12 studies from our laboratory that incorporated an ad-libitum taste test. We considered time of day and participants' awareness of the purpose of the taste test as potential confounding variables. We examined whether gender, typical alcohol consumption, subjective craving, scores on the Alcohol Use Disorders Identification Test and perceived pleasantness of the drinks predicted ad-libitum consumption (construct validity). We included 762 participants (462 female). Participant awareness and time of day were not related to ad-libitum alcohol consumption. Males drank significantly more alcohol than females (p alcohol consumption (p = 0.04), craving (p alcohol consumption. The construct validity of the taste test was supported by relationships between ad-libitum consumption and typical alcohol consumption, craving and pleasantness ratings of the drinks. The ad-libitum taste test is a valid method for the assessment of alcohol intake in the laboratory.

  16. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  17. AULA virtual reality test as an attention measure: convergent validity with Conners' Continuous Performance Test.

    Science.gov (United States)

    Díaz-Orueta, Unai; Garcia-López, Cristina; Crespo-Eguílaz, Nerea; Sánchez-Carpintero, Rocío; Climent, Gema; Narbona, Juan

    2014-01-01

    The majority of neuropsychological tests used to evaluate attention processes in children lack ecological validity. The AULA Nesplora (AULA) is a continuous performance test, developed in a virtual setting, very similar to a school classroom. The aim of the present study is to analyze the convergent validity between the AULA and the Continuous Performance Test (CPT) of Conners. The AULA and CPT were administered correlatively to 57 children, aged 6-16 years (26.3% female) with average cognitive ability (IQ mean = 100.56, SD = 10.38) who had a diagnosis of attention deficit/hyperactivity disorder (ADHD) according to DSM-IV-TR criteria. Spearman correlations analyses were conducted among the different variables. Significant correlations were observed between both tests in all the analyzed variables (omissions, commissions, reaction time, and variability of reaction time), including for those measures of the AULA based on different sensorial modalities, presentation of distractors, and task paradigms. Hence, convergent validity between both tests was confirmed. Moreover, the AULA showed differences by gender and correlation to Perceptual Reasoning and Working Memory indexes of the WISC-IV, supporting the relevance of IQ measures in the understanding of cognitive performance in ADHD. In addition, the AULA (but not Conners' CPT) was able to differentiate between ADHD children with and without pharmacological treatment for a wide range of measures related to inattention, impulsivity, processing speed, motor activity, and quality of attention focus. Additional measures and advantages of the AULA versus Conners' CPT are discussed.

  18. Vancomycin-resistant enterococci: validation of susceptibility testing and in vitro activity of novel antibiotics

    DEFF Research Database (Denmark)

    Rathe, Mathias; Lise, Kristensen,; Ellermann-Eriksen, Svend

    Vancomycin-resistant enterococci: validation of susceptibility testing and in vitro activity of novel antibiotics......Vancomycin-resistant enterococci: validation of susceptibility testing and in vitro activity of novel antibiotics...

  19. [Comparison of the Wechsler Memory Scale-III and the Spain-Complutense Verbal Learning Test in acquired brain injury: construct validity and ecological validity].

    Science.gov (United States)

    Luna-Lario, P; Pena, J; Ojeda, N

    2017-04-16

    To perform an in-depth examination of the construct validity and the ecological validity of the Wechsler Memory Scale-III (WMS-III) and the Spain-Complutense Verbal Learning Test (TAVEC). The sample consists of 106 adults with acquired brain injury who were treated in the Area of Neuropsychology and Neuropsychiatry of the Complejo Hospitalario de Navarra and displayed memory deficit as the main sequela, measured by means of specific memory tests. The construct validity is determined by examining the tasks required in each test over the basic theoretical models, comparing the performance according to the parameters offered by the tests, contrasting the severity indices of each test and analysing their convergence. The external validity is explored through the correlation between the tests and by using regression models. According to the results obtained, both the WMS-III and the TAVEC have construct validity. The TAVEC is more sensitive and captures not only the deficits in mnemonic consolidation, but also in the executive functions involved in memory. The working memory index of the WMS-III is useful for predicting the return to work at two years after the acquired brain injury, but none of the instruments anticipates the disability and dependence at least six months after the injury. We reflect upon the construct validity of the tests and their insufficient capacity to predict functionality when the sequelae become chronic.

  20. Validation of the Performance of High-level Waste Disposal System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Won Jin; Park, J. H.; Lee, J. O. (and others)

    2007-06-15

    The experimental researches to validate the integrity and safety of high-level waste disposal system were carried out. The studies on the construction of KURT, and the site rock characteristics were conducted. Thermal-hydro-mechanical behavior of engineered barrier system was investigated using the engineering-scale test facility. The migration and retardation of radionuclide through the rock fracture under anaerobic and reducing condition were studied. The distribution coefficients of radionuclides onto granite, the rock matrix diffusion coefficients, and the gap and grain boundary inventories of spent fuel were measured.

  1. Suitability Screening Test for Marine Corps Air Traffic Controllers Phase 3: Non-cognitive Test Validation and Cognitive Test Prototype

    Science.gov (United States)

    2014-06-01

    developed, pilot tested, and in its Beta form. Findings or Results The subset of NCAPS traits that demonstrated statistically significant prediction for...development and initial pilot testing of the Prototype Marine ATC Cognitive Test. Method The validation approach chosen for this project was a criterion... multitasking ability, and 5) inductive reasoning ability. A working memory capacity test was developed because working memory has been linked to

  2. The accuracy of Internet search engines to predict diagnoses from symptoms can be assessed with a validated scoring system.

    Science.gov (United States)

    Shenker, Bennett S

    2014-02-01

    To validate a scoring system that evaluates the ability of Internet search engines to correctly predict diagnoses when symptoms are used as search terms. We developed a five point scoring system to evaluate the diagnostic accuracy of Internet search engines. We identified twenty diagnoses common to a primary care setting to validate the scoring system. One investigator entered the symptoms for each diagnosis into three Internet search engines (Google, Bing, and Ask) and saved the first five webpages from each search. Other investigators reviewed the webpages and assigned a diagnostic accuracy score. They rescored a random sample of webpages two weeks later. To validate the five point scoring system, we calculated convergent validity and test-retest reliability using Kendall's W and Spearman's rho, respectively. We used the Kruskal-Wallis test to look for differences in accuracy scores for the three Internet search engines. A total of 600 webpages were reviewed. Kendall's W for the raters was 0.71 (psearch engines is a valid and reliable instrument. The scoring system may be used in future Internet research. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Validation of Metrics for Collaborative Systems

    OpenAIRE

    Ion IVAN; Cristian CIUREA

    2008-01-01

    This paper describe the new concepts of collaborative systems metrics validation. The paper define the quality characteristics of collaborative systems. There are proposed a metric to estimate the quality level of collaborative systems. There are performed measurements of collaborative systems quality using a specially designed software.

  4. 40 CFR 1048.501 - How do I run a valid emission test?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false How do I run a valid emission test... § 1048.501 How do I run a valid emission test? (a) Use the equipment and procedures for spark-ignition... 86.132-96(h) and then operate the engine for 60 minutes over repeat runs of the duty cycle specified...

  5. Unit testing, model validation, and biological simulation.

    Science.gov (United States)

    Sarma, Gopal P; Jacobs, Travis W; Watts, Mark D; Ghayoomie, S Vahid; Larson, Stephen D; Gerkin, Richard C

    2016-01-01

    The growth of the software industry has gone hand in hand with the development of tools and cultural practices for ensuring the reliability of complex pieces of software. These tools and practices are now acknowledged to be essential to the management of modern software. As computational models and methods have become increasingly common in the biological sciences, it is important to examine how these practices can accelerate biological software development and improve research quality. In this article, we give a focused case study of our experience with the practices of unit testing and test-driven development in OpenWorm, an open-science project aimed at modeling Caenorhabditis elegans. We identify and discuss the challenges of incorporating test-driven development into a heterogeneous, data-driven project, as well as the role of model validation tests, a category of tests unique to software which expresses scientific models.

  6. Validity, Reliability, and Inertia of Four Different Temperature Capsule Systems.

    Science.gov (United States)

    Bongers, Coen C W G; Daanen, Hein A M; Bogerd, Cornelis P; Hopman, Maria T E; Eijsvogels, Thijs M H

    2018-01-01

    Telemetric temperature capsule systems are wireless, relatively noninvasive, and easily applicable in field conditions and have therefore great advantages for monitoring core body temperature. However, the accuracy and responsiveness of available capsule systems have not been compared previously. Therefore, the aim of this study was to examine the validity, reliability, and inertia characteristics of four ingestible temperature capsule systems (i.e., CorTemp, e-Celsius, myTemp, and VitalSense). Ten temperature capsules were examined for each system in a temperature-controlled water bath during three trials. The water bath temperature gradually increased from 33°C to 44°C in trials 1 and 2 to assess the validity and reliability, and from 36°C to 42°C in trial 3 to assess the inertia characteristics of the temperature capsules. A systematic difference between capsule and water bath temperature was found for CorTemp (0.077°C ± 0.040°C), e-Celsius (-0.081°C ± 0.055°C), myTemp (-0.003°C ± 0.006°C), and VitalSense (-0.017°C ± 0.023°C; P 0.05). Comparable inertia characteristics were found for CorTemp (25 ± 4 s), e-Celsius (21 ± 13 s), and myTemp (19 ± 2 s), whereas the VitalSense system responded more slowly (39 ± 6 s) to changes in water bath temperature (P inertia were observed between capsule systems, an excellent validity, test-retest reliability, and inertia was found for each system between 36°C and 44°C after removal of outliers.

  7. Elaboration of a guideline for counterpart testing of integral loop systems

    International Nuclear Information System (INIS)

    Karwat, H.

    1988-01-01

    A previous study on the problems of scaling and extrapolation of experimental results indicated the necessity to overcome some uncertainty in the achievable code accuracy when applied to full size reactor systems. The empirical approach in simulating interfacial relationships within systems behaviour codes in combination with the liberty of nodalisation requires a careful assessment of the overall validity of the code verification concept. Several new test facilities are presently under construction to study fluid-dynamic effects of interest for the behaviour of PWRs under small break LOCA conditions in a larger dimension and with somewhat modified scaling considerations. The test results expected from these new facilities may be useful to assess the overall validity of the analytical simulation concept of the applied computer codes. Test facilities of interest within the European Community are the - LOBI Test Facility (vol. scaling 1/700) at JRC-Ispra - SPES Test Facility (vol. scaling 1/425) in Italy - BETHSY Facility (vol scaling 1/100) in France and outside Europe the - ROSA IV Facility (vol. scaling 1/50) in Japan. Main objective of the study was the elaboration of a guideline for the particular requirements of meaningful counterpart testing with the final aim to qualify the overall validity of code simulation concepts and the expected predictive accuracy of code applications for full size prototype PWRs

  8. Test facility of the VVER-440 condensation-type pressure suppression system

    International Nuclear Information System (INIS)

    Wolff, H.; Arndt, S.

    2004-01-01

    Since the early nineties, GRS has supported regulatory authorities in Central and Eastern Europe in performing safety assessments of nuclear power plants. Especially studies of the condensation-type pressure suppression system of VVER-440/V-213-type plants have been important in this respect. Major steps in demonstrating complete functioning of the condensation-type pressure suppression system under accident conditions by experiments run in the Russian large scale test facility, BC V-213, have been completed in the past two years within the framework of various international experimental programs. The test results were used to validate specifically for power plants with VVER-400/V-213 reactors the COCOSYS GRS computer code, which is used in the safety assessments. The results of recalculations of the C02 EREC test, which simulates a break of a main steam pipe, demonstrate the present state of validation of COCOSYS for VVER condensation-type pressure suppression systems. (orig.) [de

  9. Development and Validation of a Persian Version of Dichotic Emotional Word Test

    Directory of Open Access Journals (Sweden)

    Atefe Davudazde

    2016-03-01

    Full Text Available Introduction: Emotional words in comparison with neutral words have different hemispheric specialization. It is assumed that the right hemisphere has a role in processing every kind of emotional word. The objective of the present study was the development of a Persian version of the dichotic emotional word test and evaluate its validation among adult Persian speakers.   Materials and Methods: The present study was done on 60 adults, with the age ranging from 18-30 years for both genders, who had no history of neurological disorders with normal hearing. The developed test included eight main lists; each had several dichotic emotional/ neutral pairs of words. Participants were asked to recall as many words in each list as they could after they listened to them. A content validity index was used to analyze the validity of the test.   Results: The mean content validity index score was 0.94. The findings showed that in the left ear, emotional words were remembered more than neutral ones (P=0.007. While in the right ear, neutral words were remembered more (P=0.009. There were no significant differences in male and female scores.   Conclusion:  Dichotic emotional word test has a high content validity. The ability to remember emotional words better in the left ear supports the dominant role of the right hemisphere in emotional word perception.

  10. Portuguese validation of the children's eating attitudes test

    Directory of Open Access Journals (Sweden)

    Maria Del Carmen Bento Teixeira

    2012-01-01

    Full Text Available BACKGROUND: The Eating Attitudes Test (EAT is the most widely used instrument for evaluating eating disorders in adults and adolescents in a variety of cultures and samples. OBJECTIVE: The aim of this study was to analyse the psychometric properties of the Portuguese version of the Children's Eating Attitudes Test (ChEAT. METHOD: Nine hundred and fifty-six Portuguese secondary students (565 girls and 391 boys answered the ChEAT. The test-retest reliability was obtained with data from 206 participants from the total sample who re-answered the questionnaire after 4-6 weeks. Psychometric analyses were carried out for the total sample and separately for girls and boys. RESULTS: Internal consistency and test-retest reliability were satisfactory. Principal components factorial analysis yielded four factors in the total sample, accounting for 42.35% of the total variance. Factor structure was similar in the total sample and in both genders. Factors were labelled: F1 "Fear of Getting Fat", F2 "Restrictive and Purgative Behaviours", F3 "Food Preoccupation" and F4 "Social Pressure to Eat". The concurrent validity, explored using the Contour Drawing Figure Rating Scale (CDRS was high. DISCUSSION: The Portuguese version of the ChEAT is a valid and useful instrument for the evaluation of abnormal eating attitudes and behaviours among Portuguese adolescents.

  11. Simulation tests for cervical nonorganic signs: a study of face validity.

    Science.gov (United States)

    Vernon, Howard; Proctor, Dan; Bakalovski, Dianna; Moreton, Jesse

    2010-01-01

    The purpose of this study was to develop and determine the face validity of additional cervical nonorganic simulation tests. Four simulation tests were either selected from the literature or newly designed: simulated sitting trunk/shoulder rotation (SR; test no. 1), active vs passive cervical rotation (CR; test no. 2), Libman's test (LT; test no. 3) of pressure over the mastoid process, and side-lying passive shoulder abduction (SA; test no. 4). Three groups, 1 without neck pain (n = 44) and 2 with neck pain (n = 43 and 27), were formed. Outcome measures consisted of questions on provocation of pain (Yes/No) and appropriateness (Yes/No) as well as measurements of cervical rotation (goniometric) and pressure pain threshold (pressure algometer). Group test responses were evaluated and scored. A threshold of acceptance was established at 80% agreement for face validity. Ranges of rotation and pressure threshold values were analyzed with the Student t test. In nonneck pain subjects, all 4 tests were rated as nonpainful and 3 were rated as "appropriate" for neck pain examination (not SR). In neck pain subjects, this test and SA were rated as nonpainful, whereas LT was rated as painful in 26% of subjects. Only CR and LT were rated as "appropriate." In neck pain subjects, passive rotations exceeded actives by 10% to 14% (P = .000). On a second round of testing with a slightly modified method, SR and SA achieved acceptable "appropriateness." Once 2 tests were slightly modified, all 4 tests were found to have acceptable face validity. Further research into the reliability of these tests as well as into the combinations of these tests is warranted. Copyright 2010 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  12. Validation of Metrics for Collaborative Systems

    Directory of Open Access Journals (Sweden)

    Ion IVAN

    2008-01-01

    Full Text Available This paper describe the new concepts of collaborative systems metrics validation. The paper define the quality characteristics of collaborative systems. There are proposed a metric to estimate the quality level of collaborative systems. There are performed measurements of collaborative systems quality using a specially designed software.

  13. Integrated System Health Management: Pilot Operational Implementation in a Rocket Engine Test Stand

    Science.gov (United States)

    Figueroa, Fernando; Schmalzel, John L.; Morris, Jonathan A.; Turowski, Mark P.; Franzl, Richard

    2010-01-01

    This paper describes a credible implementation of integrated system health management (ISHM) capability, as a pilot operational system. Important core elements that make possible fielding and evolution of ISHM capability have been validated in a rocket engine test stand, encompassing all phases of operation: stand-by, pre-test, test, and post-test. The core elements include an architecture (hardware/software) for ISHM, gateways for streaming real-time data from the data acquisition system into the ISHM system, automated configuration management employing transducer electronic data sheets (TEDS?s) adhering to the IEEE 1451.4 Standard for Smart Sensors and Actuators, broadcasting and capture of sensor measurements and health information adhering to the IEEE 1451.1 Standard for Smart Sensors and Actuators, user interfaces for management of redlines/bluelines, and establishment of a health assessment database system (HADS) and browser for extensive post-test analysis. The ISHM system was installed in the Test Control Room, where test operators were exposed to the capability. All functionalities of the pilot implementation were validated during testing and in post-test data streaming through the ISHM system. The implementation enabled significant improvements in awareness about the status of the test stand, and events and their causes/consequences. The architecture and software elements embody a systems engineering, knowledge-based approach; in conjunction with object-oriented environments. These qualities are permitting systematic augmentation of the capability and scaling to encompass other subsystems.

  14. A Vehicle Management End-to-End Testing and Analysis Platform for Validation of Mission and Fault Management Algorithms to Reduce Risk for NASA's Space Launch System

    Science.gov (United States)

    Trevino, Luis; Patterson, Jonathan; Teare, David; Johnson, Stephen

    2015-01-01

    integrates specific M&FM algorithms, specialized nominal and off-nominal test cases, and vendor-supplied physics-based launch vehicle subsystem models. Additionally, the team has developed processes for implementing and validating these algorithms for concept validation and risk reduction for the SLS program. The flexibility of the Vehicle Management End-to-end Testbed (VMET) enables thorough testing of the M&FM algorithms by providing configurable suites of both nominal and off-nominal test cases to validate the developed algorithms utilizing actual subsystem models such as MPS. The intent of VMET is to validate the M&FM algorithms and substantiate them with performance baselines for each of the target vehicle subsystems in an independent platform exterior to the flight software development infrastructure and its related testing entities. In any software development process there is inherent risk in the interpretation and implementation of concepts into software through requirements and test cases into flight software compounded with potential human errors throughout the development lifecycle. Risk reduction is addressed by the M&FM analysis group working with other organizations such as S&MA, Structures and Environments, GNC, Orion, the Crew Office, Flight Operations, and Ground Operations by assessing performance of the M&FM algorithms in terms of their ability to reduce Loss of Mission and Loss of Crew probabilities. In addition, through state machine and diagnostic modeling, analysis efforts investigate a broader suite of failure effects and associated detection and responses that can be tested in VMET to ensure that failures can be detected, and confirm that responses do not create additional risks or cause undesired states through interactive dynamic effects with other algorithms and systems. VMET further contributes to risk reduction by prototyping and exercising the M&FM algorithms early in their implementation and without any inherent hindrances such as meeting FSW

  15. Validation Of Critical Knowledge-Based Systems

    Science.gov (United States)

    Duke, Eugene L.

    1992-01-01

    Report discusses approach to verification and validation of knowledge-based systems. Also known as "expert systems". Concerned mainly with development of methodologies for verification of knowledge-based systems critical to flight-research systems; e.g., fault-tolerant control systems for advanced aircraft. Subject matter also has relevance to knowledge-based systems controlling medical life-support equipment or commuter railroad systems.

  16. Computer Assisted Testing of Spoken English: A Study of the SFLEP College English Oral Test System in China

    Directory of Open Access Journals (Sweden)

    John Lowe

    2009-06-01

    Full Text Available This paper reports on the on-going evaluation of a computer-assisted system (CEOTS for the assessing of spoken English skills among Chinese university students. This system is being developed to deal with the negative backwash effects of the present system of assessment of speaking skills which is only available to a tiny minority. We present data from a survey of students at the developing institution (USTC, with follow-up interviews and further interviews with English language teachers, to gauge the reactions to the test and its impact on language learning. We identify the key issue as being one of validity, with a tension existing between construct and consequential validities of the existing system and of CEOTS. We argue that a computer-based system seems to offer the only solution to the negative backwash problem but the development of the technology required to meet current construct validity demands makes this a very long term prospect. We suggest that a compromise between the competing forms of validity must therefore be accepted, probably well before a computer-based system can deliver the level of interaction with the examinees that would emulate the present face-to-face mode.

  17. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  18. Validity of the American Sign Language Discrimination Test

    Science.gov (United States)

    Bochner, Joseph H.; Samar, Vincent J.; Hauser, Peter C.; Garrison, Wayne M.; Searls, J. Matt; Sanders, Cynthia A.

    2016-01-01

    American Sign Language (ASL) is one of the most commonly taught languages in North America. Yet, few assessment instruments for ASL proficiency have been developed, none of which have adequately demonstrated validity. We propose that the American Sign Language Discrimination Test (ASL-DT), a recently developed measure of learners' ability to…

  19. Functional Literacy Tests: A Case of Anticipatory Validity?

    Science.gov (United States)

    Anderson, Lorin W.; Anderson, Jo Craig

    1981-01-01

    Development of the mathematics functional literacy test (MFLT) is described, issues of predictive and content validity are discussed, and implications for educational policy are presented. Ten basic skill areas identified by the National Council of Supervisors of Mathematics were used as the basis for the development of the MFLT. (RL)

  20. Experimental validation of the 'DELFIN' system with heavy water multicell measurements

    International Nuclear Information System (INIS)

    Grant, C.R.

    1990-01-01

    The DELFIN system, developed by the Analysis and Calculation Department of the Nuclear Power Plants Branch of the National Atomic Energy Commission, uses the finite elements method for the neutronic networks simulation and was validated through comparisons with other calculation codes and experiences with MTR (Materials Testing Reactors) reactors. This work compares calculations applying this system, with experiences carried out at the ZED-2 Canadian research reactor with vertical and horizontal adjusting steel rods, that is, bi- and tridimensional cases. (Author) [es

  1. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  2. Cognitive Bias in the Verification and Validation of Space Flight Systems

    Science.gov (United States)

    Larson, Steve

    2012-01-01

    Cognitive bias is generally recognized as playing a significant role in virtually all domains of human decision making. Insight into this role is informally built into many of the system engineering practices employed in the aerospace industry. The review process, for example, typically has features that help to counteract the effect of bias. This paper presents a discussion of how commonly recognized biases may affect the verification and validation process. Verifying and validating a system is arguably more challenging than development, both technically and cognitively. Whereas there may be a relatively limited number of options available for the design of a particular aspect of a system, there is a virtually unlimited number of potential verification scenarios that may be explored. The probability of any particular scenario occurring in operations is typically very difficult to estimate, which increases reliance on judgment that may be affected by bias. Implementing a verification activity often presents technical challenges that, if they can be overcome at all, often result in a departure from actual flight conditions (e.g., 1-g testing, simulation, time compression, artificial fault injection) that may raise additional questions about the meaningfulness of the results, and create opportunities for the introduction of additional biases. In addition to mitigating the biases it can introduce directly, the verification and validation process must also overcome the cumulative effect of biases introduced during all previous stages of development. A variety of cognitive biases will be described, with research results for illustration. A handful of case studies will be presented that show how cognitive bias may have affected the verification and validation process on recent JPL flight projects, identify areas of strength and weakness, and identify potential changes or additions to commonly used techniques that could provide a more robust verification and validation of

  3. The validity of Cloze Oriented System (COS: a correlation study with an electronic comprehension test and a reading attitude survey

    Directory of Open Access Journals (Sweden)

    Maria Cristina Rodrigues Azevedo Joly

    Full Text Available This study aimed to analyze the efficiency of the Cloze Oriented System (COS considering its relation with reading attitude and its validity. The Electronic Program Comprehension (EPC for students from K1 to K4 based on the COS parts of stories from the Brazilian Children's literature was applied in eighteen class-hours. The 40 subjects, ten in each grade, of both genders aged 7 to 11 years, were evaluated before and after the EPC with a Cloze test. They answered the Elementary Reading Attitude Survey too, in a printed protocol adapted to Portuguese, to evaluate the reading attitude of the students and the influence of the EPC in the academic and recreational reading. The results showed that the performance in reading comprehension of all the subjects was higher after taking part in the EPC, and also had significant differences in reading attitude, according to the results of the T of Wilcoxon statistic test. A correlation between comprehension performance before and after the EPC and the reading attitude was verified. There was significant difference for academic reading attitude in the post-test between proficient readers and the one's that has low skill.

  4. Water evaporation over sump surface in nuclear containment studies: CFD and LP codes validation on TOSQAN tests

    Energy Technology Data Exchange (ETDEWEB)

    Malet, J., E-mail: jeanne.malet@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA BP 68, 91192 Gif-sur-Yvette (France); Degrees du Lou, O. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA BP 68, 91192 Gif-sur-Yvette (France); Arts et Métiers ParisTech, DynFluid Lab. EA92, 151, boulevard de l’Hôpital, 75013 Paris (France); Gelain, T. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA BP 68, 91192 Gif-sur-Yvette (France)

    2013-10-15

    Highlights: • Simulations of evaporative TOSQAN sump tests are performed. • These tests are under air–steam gas conditions with addition of He, CO{sub 2} and SF{sub 6}. • ASTEC-CPA LP and TONUS-CFD codes with UDF for sump model are used. • Validation of sump models of both codes show good results. • The code–experiment differences are attributed to turbulent gas mixing modeling. -- Abstract: During the course of a severe accident in a Nuclear Power Plant, water can be collected in the sump containment through steam condensation on walls and spray systems activation. The objective of this paper is to present code validation on evaporative sump tests performed on TOSQAN facility. The ASTEC-CPA code is used as a lumped-parameter code and specific user-defined-functions are developed for the TONUS-CFD code. The seven tests are air–steam tests, as well as tests with other non-condensable gases (He, CO{sub 2} and SF{sub 6}) under steady and transient conditions (two depressurization tests). The results show a good agreement between codes and experiments, indicating a good behavior of the sump models in both codes. The sump model developed as User-Defined Functions (UDF) for TONUS is considered as well validated and is ‘ready-to-use’ for all CFD codes in which such UDF can be added. The remaining discrepancies between codes and experiments are caused by turbulent transport and gas mixing, especially in the presence of non-condensable gases other than air, so that code validation on this important topic for hydrogen safety analysis is still recommended.

  5. Tank Monitor and Control System (TMACS) Rev 11.0 Acceptance Test Review

    Energy Technology Data Exchange (ETDEWEB)

    HOLM, M.J.

    1999-08-25

    The purpose of this document is to describe tests performed to validate Revision 11 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab.

  6. A standardized approach to verification and validation to assist in expert system development

    International Nuclear Information System (INIS)

    Hines, J.W.; Hajek, B.K.; Miller, D.W.; Haas, M.A.

    1992-01-01

    For the past six years, the Nuclear Engineering Program's Artificial Intelligence (AI) Group at The Ohio State University has been developing an integration of expert systems to act as an aid to nuclear power plant operators. This Operator Advisor consists of four modules that monitor plant parameters, detect deviations from normality, diagnose the root cause of the abnormality, manage procedures to effectively respond to the abnormality, and mitigate its consequences. To aid in the development of this new system, a standardized Verification and Validation (V and V) approach is being implemented. The primary functions are to guide the development of the expert system and to ensure that the end product fulfills the initial objectives. The development process has been divided into eight life-cycle V and V phases from concept to operation and maintenance. Each phase has specific V and V tasks to be performed to ensure a quality end product. Four documents are being used to guide development. The Software Verification and Validation Plan (SVVP) outlines the V and V tasks necessary to verify the product at the end of each software development phase, and to validate that the end product complies with the established software and system requirements and meets the needs of the user. The Software Requirements Specification (SRS) documents the essential requirements of the system. The Software Design Description (SDD) represents these requirements with a specific design. And lastly, the Software Test Document establishes a testing methodology to be used throughout the development life-cycle

  7. The validation of waste assay systems during active test at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Tamura, Takayuki; Miura, Yasushi; Iwamoto, Tomonori

    2007-01-01

    In order to implement accurate material accountancy at Rokkasho Reprocessing Plant (RRP) as a large scale reprocessing plant, it is necessary to introduce accurate measurement systems not only for mainstream material, but also appropriate measurement systems for solid waste materials. In this sense, the generated wastes by the active test operation have been measured with the Non-Destructive Assay Systems, such as Rokkasho Hulls Measurement System (RHMS) and Waste Crate Assay System (WCAS) for accountancy. This paper describes the experience of the NDA operation and the evaluation results for accountancy. (author)

  8. Automatic control system generation for robot design validation

    Science.gov (United States)

    Bacon, James A. (Inventor); English, James D. (Inventor)

    2012-01-01

    The specification and drawings present a new method, system and software product for and apparatus for generating a robotic validation system for a robot design. The robotic validation system for the robot design of a robotic system is automatically generated by converting a robot design into a generic robotic description using a predetermined format, then generating a control system from the generic robotic description and finally updating robot design parameters of the robotic system with an analysis tool using both the generic robot description and the control system.

  9. Validation of a diabetes numeracy test in Arabic

    OpenAIRE

    Alghodaier, Hussah; Jradi, Hoda; Mohammad, Najwa Samantha; Bawazir, Amen

    2017-01-01

    Background The prevalence of diabetes Mellitus in Saudi Arabia is 24%, ranking it among the top ten Worldwide. Diabetes education focuses on self-management and relies on numeracy skills. Poor numeracy may go unrecognized and it is important to have an assessment tool in Arabic to measure such a skill in diabetes care. Objectives To validate a 15-item Diabetes Numeracy Test (DNT-15) in the Arabic Language as a tool to assess the numeracy skills of patients with diabetes and to test its proper...

  10. Validity of eyeball estimation for range of motion during the cervical flexion rotation test compared to an ultrasound-based movement analysis system.

    Science.gov (United States)

    Schäfer, Axel; Lüdtke, Kerstin; Breuel, Franziska; Gerloff, Nikolas; Knust, Maren; Kollitsch, Christian; Laukart, Alex; Matej, Laura; Müller, Antje; Schöttker-Königer, Thomas; Hall, Toby

    2018-08-01

    Headache is a common and costly health problem. Although pathogenesis of headache is heterogeneous, one reported contributing factor is dysfunction of the upper cervical spine. The flexion rotation test (FRT) is a commonly used diagnostic test to detect upper cervical movement impairment. The aim of this cross-sectional study was to investigate concurrent validity of detecting high cervical ROM impairment during the FRT by comparing measurements established by an ultrasound-based system (gold standard) with eyeball estimation. Secondary aim was to investigate intra-rater reliability of FRT ROM eyeball estimation. The examiner (6 years experience) was blinded to the data from the ultrasound-based device and to the symptoms of the patients. FRT test result (positive or negative) was based on visual estimation of range of rotation less than 34° to either side. Concurrently, range of rotation was evaluated using the ultrasound-based device. A total of 43 subjects with headache (79% female), mean age of 35.05 years (SD 13.26) were included. According to the International Headache Society Classification 23 subjects had migraine, 4 tension type headache, and 16 multiple headache forms. Sensitivity and specificity were 0.96 and 0.89 for combined rotation, indicating good concurrent reliability. The area under the ROC curve was 0.95 (95% CI 0.91-0.98) for rotation to both sides. Intra-rater reliability for eyeball estimation was excellent with Fleiss Kappa 0.79 for right rotation and left rotation. The results of this study indicate that the FRT is a valid and reliable test to detect impairment of upper cervical ROM in patients with headache.

  11. Validation of the Read Out Electronics for the CMS Muon Drift Chambers at Tests Beam in CERN/GIF

    CERN Document Server

    Fernández, C; Fouz-Iglesias, M C; Marin, J; Oller, J C; Willmott, C

    2002-01-01

    Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs.

  12. Testing ESL pragmatics development and validation of a web-based assessment battery

    CERN Document Server

    Roever, Carsten

    2014-01-01

    Although second language learners' pragmatic competence (their ability to use language in context) is an essential part of their general communicative competence, it has not been a part of second language tests. This book helps fill this gap by describing the development and validation of a web-based test of ESL pragmalinguistics. The instrument assesses learners' knowledge of routine formulae, speech acts, and implicature in 36 multiple-choice and brief-response items. The test's quantitative and qualitative validation with 300 learners showed high reliability and provided strong evidence of

  13. Validity and Utilization of the Out-Pile Testing Facilities at HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee-Nam; Cho, Man-Soon; Yang, Sung-Woo; Shin, Yoon-Taek; Park, Seng-Jae; Jun, Byung-Hyuk; Kim, Myong-Seop [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Various neutron irradiation facilities such as rabbit irradiation facilities, loop facilities and the capsule irradiation facilities for irradiation tests of nuclear materials, fuels and radioisotope products have been developed at HANARO. Among these irradiation facilities, the capsule is the most useful device for coping with the various test requirements at HANARO. To support the national research and development programs on nuclear reactors and the nuclear fuel cycle technology in Korea, new irradiation capsules have been developed and actively utilized for the irradiation tests requested by numerous users. The environmental conditions for these reactors are generally beyond present day reactor technology, especially regarding the higher neutron fluence and higher operating temperature. To effectively support the national R and Ds relevant to the future nuclear systems, the development of advanced irradiation technologies concerning higher neutron fluence and irradiation temperature are being preferentially developed at HANARO. The utilization of the out-pile testing facilities to satisfy the criteria of safety evaluation for a new device installed in the core of HANARO was summarized. In addition, the validity of the out-pile testing facilities was evaluated and proved to be effective for verifying the integrity of irradiation capsule.

  14. Validity and Utilization of the Out-Pile Testing Facilities at HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Cho, Man-Soon; Yang, Sung-Woo; Shin, Yoon-Taek; Park, Seng-Jae; Jun, Byung-Hyuk; Kim, Myong-Seop

    2016-01-01

    Various neutron irradiation facilities such as rabbit irradiation facilities, loop facilities and the capsule irradiation facilities for irradiation tests of nuclear materials, fuels and radioisotope products have been developed at HANARO. Among these irradiation facilities, the capsule is the most useful device for coping with the various test requirements at HANARO. To support the national research and development programs on nuclear reactors and the nuclear fuel cycle technology in Korea, new irradiation capsules have been developed and actively utilized for the irradiation tests requested by numerous users. The environmental conditions for these reactors are generally beyond present day reactor technology, especially regarding the higher neutron fluence and higher operating temperature. To effectively support the national R and Ds relevant to the future nuclear systems, the development of advanced irradiation technologies concerning higher neutron fluence and irradiation temperature are being preferentially developed at HANARO. The utilization of the out-pile testing facilities to satisfy the criteria of safety evaluation for a new device installed in the core of HANARO was summarized. In addition, the validity of the out-pile testing facilities was evaluated and proved to be effective for verifying the integrity of irradiation capsule

  15. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    OpenAIRE

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administer...

  16. The Unified Language Testing Plan: Speaking Proficiency Test. Spanish and English Pilot Validation Studies. Report Number 1.

    Science.gov (United States)

    Thornton, Julie A.

    This report describes one segment of the Federal Language Testing Board's Unified Language Testing Plan (ULTP), the validation of speaking proficiency tests in Spanish and English. The ULTP is a project to increase standardization of foreign language proficiency measurement and promote sharing of resources among testing programs in the federal…

  17. Screening for cognitive impairment in older individuals. Validation study of a computer-based test.

    Science.gov (United States)

    Green, R C; Green, J; Harrison, J M; Kutner, M H

    1994-08-01

    This study examined the validity of a computer-based cognitive test that was recently designed to screen the elderly for cognitive impairment. Criterion-related validity was examined by comparing test scores of impaired patients and normal control subjects. Construct-related validity was computed through correlations between computer-based subtests and related conventional neuropsychological subtests. University center for memory disorders. Fifty-two patients with mild cognitive impairment by strict clinical criteria and 50 unimpaired, age- and education-matched control subjects. Control subjects were rigorously screened by neurological, neuropsychological, imaging, and electrophysiological criteria to identify and exclude individuals with occult abnormalities. Using a cut-off total score of 126, this computer-based instrument had a sensitivity of 0.83 and a specificity of 0.96. Using a prevalence estimate of 10%, predictive values, positive and negative, were 0.70 and 0.96, respectively. Computer-based subtests correlated significantly with conventional neuropsychological tests measuring similar cognitive domains. Thirteen (17.8%) of 73 volunteers with normal medical histories were excluded from the control group, with unsuspected abnormalities on standard neuropsychological tests, electroencephalograms, or magnetic resonance imaging scans. Computer-based testing is a valid screening methodology for the detection of mild cognitive impairment in the elderly, although this particular test has important limitations. Broader applications of computer-based testing will require extensive population-based validation. Future studies should recognize that normal control subjects without a history of disease who are typically used in validation studies may have a high incidence of unsuspected abnormalities on neurodiagnostic studies.

  18. Method and practice on safety software verification and validation for digital reactor protection system

    International Nuclear Information System (INIS)

    Li Duo; Zhang Liangju; Feng Junting

    2010-01-01

    The key issue arising from digitalization of reactor protection system for Nuclear Power Plant (NPP) is in essence, how to carry out Verification and Validation (V and V), to demonstrate and confirm the software is reliable enough to perform reactor safety functions. Among others the most important activity of software V and V process is unit testing. This paper discusses the basic concepts on safety software V and V and the appropriate technique for software unit testing, focusing on such aspects as how to ensure test completeness, how to establish test platform, how to develop test cases and how to carry out unit testing. The technique discussed herein was successfully used in the work of unit testing on safety software of a digital reactor protection system. (author)

  19. International exchange on nuclear safety related expert systems: The role of software verification and validation

    International Nuclear Information System (INIS)

    Sun, B.K.H.

    1996-01-01

    An important lesson learned from the Three Mile Island accident is that human errors can be significant contributors to risk. Recent advancement in computer hardware and software technology helped make expert system techniques potentially viable tools for improving nuclear power plant safety and reliability. As part of the general man-machine interface technology, expert systems have recently become increasingly prominent as a potential solution to a number of previously intractable problems in many phases of human activity, including operation, maintenance, and engineering functions. Traditional methods for testing and analyzing analog systems are no longer adequate to handle the increased complexity of software systems. The role of Verification and Validation (V and V) is to add rigor to the software development and maintenance cycle to guarantee the high level confidence needed for applications. Verification includes the process and techniques for confirming that all the software requirements in one stage of the development are met before proceeding on to the next stage. Validation involves testing the integrated software and hardware system to ensure that it reliably fulfills its intended functions. Only through a comprehensive V and V program can a high level of confidence be achieved. There exist many different standards and techniques for software verification and validation, yet they lack uniform approaches that provides adequate levels of practical guidance which can be used by users for nuclear power plant applications. There is a need to unify different approaches for addressing software verification and validation and to develop practical and cost effective guidelines for user and regulatory acceptance. (author). 8 refs

  20. Fault-tolerant clock synchronization validation methodology. [in computer systems

    Science.gov (United States)

    Butler, Ricky W.; Palumbo, Daniel L.; Johnson, Sally C.

    1987-01-01

    A validation method for the synchronization subsystem of a fault-tolerant computer system is presented. The high reliability requirement of flight-crucial systems precludes the use of most traditional validation methods. The method presented utilizes formal design proof to uncover design and coding errors and experimentation to validate the assumptions of the design proof. The experimental method is described and illustrated by validating the clock synchronization system of the Software Implemented Fault Tolerance computer. The design proof of the algorithm includes a theorem that defines the maximum skew between any two nonfaulty clocks in the system in terms of specific system parameters. Most of these parameters are deterministic. One crucial parameter is the upper bound on the clock read error, which is stochastic. The probability that this upper bound is exceeded is calculated from data obtained by the measurement of system parameters. This probability is then included in a detailed reliability analysis of the system.

  1. Magnetic Signature Analysis & Validation System

    National Research Council Canada - National Science Library

    Vliet, Scott

    2001-01-01

    The Magnetic Signature Analysis and Validation (MAGSAV) System is a mobile platform that is used to measure, record, and analyze the perturbations to the earth's ambient magnetic field caused by object such as armored vehicles...

  2. Validation and Design Science Research in Information Systems

    NARCIS (Netherlands)

    Sol, H G; Gonzalez, Rafael A.; Mora, Manuel

    2012-01-01

    Validation within design science research in Information Systems (DSRIS) is much debated. The relationship of validation to artifact evaluation is still not clear. This chapter aims at elucidating several components of DSRIS in relation to validation. The role of theory and theorizing are an

  3. Exploring the Reliability and Validity of the Social-Moral Awareness Test

    Science.gov (United States)

    Livesey, Alexandra; Dodd, Karen; Pote, Helen; Marlow, Elizabeth

    2012-01-01

    Background: The aim of the study was to explore the validity of the social-moral awareness test (SMAT) a measure designed for assessing socio-moral rule knowledge and reasoning in people with learning disabilities. Comparisons between Theory of Mind and socio-moral reasoning allowed the exploration of construct validity of the tool. Factor…

  4. Construction of a test platform for Test Blanket Module (TBM) systems integration and maintenance in ITER Port Cell #16

    Energy Technology Data Exchange (ETDEWEB)

    Vála, Ladislav, E-mail: ladislav.vala@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Reungoat, Mathieu, E-mail: mathieu.reungoat@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Vician, Martin [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Poitevin, Yves; Ricapito, Italo; Zmitko, Milan; Panayotov, Dobromir [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2015-10-15

    Highlights: • A non-nuclear, full size facility – TBM platform – is under construction in CVR. • It is designed for tests, optimization and validation of TBS maintenance operations. • It will allow testing and validation of specific maintenance tools and RH equipment. • It reproduces ITER Port Cell #16, as well as the TBS interfaces and main equipment. • The TBM platform will be available for full operation in the first half of 2016. - Abstract: This paper describes a project of a non-nuclear, 1:1 scale testing platform dedicated to tests, optimization and validation of integration and maintenance operations for the European TBM systems in the ITER Port Cell #16. This TBM platform is currently under construction in Centrum výzkumu Řež, Czech Republic. The facility is realized within the scope of the SUSEN project and its full operation is foreseen in the first half of 2016.

  5. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    Directory of Open Access Journals (Sweden)

    Sayed Hadi Sayed Alitabar

    2016-05-01

    Full Text Available Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST. Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. The DAST Was Used as Instrument. Divergent & Convergent Validity of this Scale Was Assessed with Problems Assessment for Substance Using Psychiatric Patients (PASUPP and Relapse Prediction Scale (RPS.Results: The DAST after the First Time Factor Structure of Using Confirmatory Factor Analysis Was Confirmed. The DAST Had a Good Internal Consistency (Cranach’s Alpha, and the Reliability of the Test Within a Week, 0.9, 0.8. Also this Scale Had a Positive Correlation with Problems Assessment for Substance Using Psychiatric Patients and Relapse Prediction Scale (P<0.01.Conclusion: The Overall Results Showed that the Drug Abuse Screening Test in Iranian Society Is Valid. It Can Be Said that Self-Report Scale Tool Is Useful for Research Purposes and Addiction.

  6. Design and validation of a CT-guided robotic system for lung cancer brachytherapy.

    Science.gov (United States)

    Dou, Huaisu; Jiang, Shan; Yang, Zhiyong; Sun, Luqing; Ma, Xiaodong; Huo, Bin

    2017-09-01

    Currently, lung brachytherapy in clinical setting is a complex procedure. Operation accuracy depends on accurate positioning of the template; however, it is difficult to guarantee the positioning accuracy manually. Application of robotic-assisted systems can simplify the procedure and improve the manual positioning accuracy. Therefore, a novel CT-guided robotic system was developed to assist the lung cancer brachytherapy. A four degree-of-freedom (DOF) robot, controlled by a lung brachytherapy treatment planning system (TPS) software, was designed and manufactured to assist the template positioning. Target position of the template can be obtained from the treatment plan, thus the robot is driven to the target position automatically. The robotic system was validated in both the laboratory and the CT environment. In laboratory environment, a 3D laser tracker and an inertial measurement unit (IMU) were used to measure the mechanical accuracy in air, which includes positioning accuracy and position repeatability. Working reliability was also validated in this procedure by observing the response reliability and calculating the position repeatability. Imaging artifacts and accuracy of the robot registration were validated in the CT environment by using an artificial phantom with fiducial markers. CT images were obtained and used to test the image artifact and calculate the registration accuracy. Phantom experiments were conducted to test the accuracy of needle insertion by using a transparent hydrogel phantom with a high imitation artificial phantom. Also, the efficiency was validated in this procedure by comparing time costs in manual positioning with robotic positioning under the same experimental conditions. The robotic system achieved the positioning accuracy of 0.28 ± 0.25 mm and the position repeatability of 0.09 ± 0.11 mm. Experimental results showed that the robot was CT-compatible and responded reliably to the control commands. The mean registration accuracy

  7. The Communication Function Classification System: cultural adaptation, validity, and reliability of the Farsi version for patients with cerebral palsy.

    Science.gov (United States)

    Soleymani, Zahra; Joveini, Ghodsiye; Baghestani, Ahmad Reza

    2015-03-01

    This study developed a Farsi language Communication Function Classification System and then tested its reliability and validity. Communication Function Classification System is designed to classify the communication functions of individuals with cerebral palsy. Up until now, there has been no instrument for assessment of this communication function in Iran. The English Communication Function Classification System was translated into Farsi and cross-culturally modified by a panel of experts. Professionals and parents then assessed the content validity of the modified version. A backtranslation of the Farsi version was confirmed by the developer of the English Communication Function Classification System. Face validity was assessed by therapists and parents of 10 patients. The Farsi Communication Function Classification System was administered to 152 individuals with cerebral palsy (age, 2 to 18 years; median age, 10 years; mean age, 9.9 years; standard deviation, 4.3 years). Inter-rater reliability was analyzed between parents, occupational therapists, and speech and language pathologists. The test-retest reliability was assessed for 75 patients with a 14 day interval between tests. The inter-rater reliability of the Communication Function Classification System was 0.81 between speech and language pathologists and occupational therapists, 0.74 between parents and occupational therapists, and 0.88 between parents and speech and language pathologists. The test-retest reliability was 0.96 for occupational therapists, 0.98 for speech and language pathologists, and 0.94 for parents. The findings suggest that the Farsi version of Communication Function Classification System is a reliable and valid measure that can be used in clinical settings to assess communication function in patients with cerebral palsy. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Improved mutagen-testing systems in mice: Comprehensive progress report, 1 September 1984 to 31 August 1987

    International Nuclear Information System (INIS)

    Roderick, T.H.

    1987-01-01

    The purpose of this project is to produce improved mutagen-testing systems in mice. Our approach is to produce chromosomal inversion systems in order to improve the techniques necessary to induce, detect, genetically define, and combine inversions in effective and useful mutation-test systems. Another specific objective has been to validate and test the systems produced with respect to their effectiveness in uncovering induced or naturally occurring recessive detrimentals or recessive lethals. Another object has been to mark, maintain, and study these induced recessive lethals induced during the validation-testing. A final broad objective has been to use the induced inversions and recessive lethals for studies of basic problems in mammalian genetics, genetic recombination, gene mapping, fertility, growth, and development

  9. Test of Creative Imagination: Validity and Reliability Study

    Science.gov (United States)

    Gundogan, Aysun; Ari, Meziyet; Gonen, Mubeccel

    2013-01-01

    The purpose of this study was to investigate validity and reliability of the test of creative imagination. This study was conducted with the participation of 1000 children, aged between 9-14 and were studying in six primary schools in the city center of Denizli Province, chosen by cluster ratio sampling. In the study, it was revealed that the…

  10. Reliability and validity of two isometric squat tests.

    Science.gov (United States)

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p squat and FHS test performances (r squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  11. Validity and reliability of skill-related fitness tests for wheelchair-using youth with Spina Bifida.

    NARCIS (Netherlands)

    Bloemen, M.A.; Takken, T.; Backx, F.J.; Vos, M.; Kruitwagen, C.L.; Groot, J.F. de

    2017-01-01

    Objectives: To determine content validity of the Muscle Power Sprint Test (MPST), and construct validity and reliability of the MPST, 10x5 Meter Sprint Test (10x5MST), slalom test, and One Stroke Push Test (1SPT) in wheelchair-using youth with spina bifida (SB). Design: Clinimetric study. Setting:

  12. Validity and Reliability of Skill-Related Fitness Tests for Wheelchair-Using Youth With Spina Bifida

    NARCIS (Netherlands)

    Bloemen, Manon A.; Takken, Tim; Backx, Frank J.; Vos, Marleen; Kruitwagen, Cas L.; de Groot, Janke F.

    OBJECTIVE: To determine content validity of the Muscle Power Sprint Test (MPST) and construct validity and reliability of the MPST, 10x5 Meter Sprint Test (10x5MST), slalom test and one stroke push test (1SPT) in wheelchair-using youth with spina bifida (SB). DESIGN: Clinimetric study SETTING:

  13. Validity and Reliability of Skill-Related Fitness Tests for Wheelchair-Using Youth with Spina Bifida

    NARCIS (Netherlands)

    Cas L.J.J. Kruitwagen; Frank J.G. Backx; Tim Takken; Janke de Groot; Marleen Vos; Manon A.T. Bloemen

    2016-01-01

    Objective: To determine content validity of the Muscle Power Sprint Test (MPST) and construct validity and reliability of the MPST, 10x5 Meter Sprint Test (10x5MST), slalom test and one stroke push test (1SPT) in wheelchair-using youth with spina bifida (SB). Design: Clinimetric study Setting:

  14. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (preliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  15. Advisory expert system for test rig operator

    International Nuclear Information System (INIS)

    Zielczynski, P.

    1994-01-01

    The advisory expert system MAESTRO (Modular Advisory Expert System for Test Rig Operator) has been designed to guide the operator of large experimental installation during start-up, steady state and shut down. The installation is located in the research reactor MARIA in the Institute of Atomic Energy in Swierk, Poland. The system acquires and analyses on line signals from installation and performs two tasks in real time: leading the operator and monitoring of the installation (including signal validation). Systems tasks, architecture and knowledge representation concepts are described. The system is based on expert systems techniques what makes in phases of continuous change of process parameters and it has been achieved by special knowledge representation allowing its dynamical modification. (author). 147 refs, 42 figs, 5 tab

  16. Engineered Barrier System Thermal-Hydraulic-Chemical Column Test Report

    International Nuclear Information System (INIS)

    W.E. Lowry

    2001-01-01

    The Engineered Barrier System (EBS) Thermal-Hydraulic-Chemical (THC) Column Tests provide data needed for model validation. The EBS Degradation, Flow, and Transport Process Modeling Report (PMR) will be based on supporting models for in-drift THC coupled processes, and the in-drift physical and chemical environment. These models describe the complex chemical interaction of EBS materials, including granular materials, with the thermal and hydrologic conditions that will be present in the repository emplacement drifts. Of particular interest are the coupled processes that result in mineral and salt dissolution/precipitation in the EBS environment. Test data are needed for thermal, hydrologic, and geochemical model validation and to support selection of introduced materials (CRWMS M and O 1999c). These column tests evaluated granular crushed tuff as potential invert ballast or backfill material, under accelerated thermal and hydrologic environments. The objectives of the THC column testing are to: (1) Characterize THC coupled processes that could affect performance of EBS components, particularly the magnitude of permeability reduction (increases or decreases), the nature of minerals produced, and chemical fractionation (i.e., concentrative separation of salts and minerals due to boiling-point elevation). (2) Generate data for validating THC predictive models that will support the EBS Degradation, Flow, and Transport PMR, Rev. 01

  17. Assessing cultural validity in standardized tests in stem education

    Science.gov (United States)

    Gassant, Lunes

    This quantitative ex post facto study examined how race and gender, as elements of culture, influence the development of common misconceptions among STEM students. Primary data came from a standardized test: the Digital Logic Concept Inventory (DLCI) developed by Drs. Geoffrey L. Herman, Michael C. Louis, and Craig Zilles from the University of Illinois at Urbana-Champaign. The sample consisted of a cohort of 82 STEM students recruited from three universities in Northern Louisiana. Microsoft Excel and the Statistical Package for the Social Sciences (SPSS) were used for data computation. Two key concepts, several sub concepts, and 19 misconceptions were tested through 11 items in the DLCI. Statistical analyses based on both the Classical Test Theory (Spearman, 1904) and the Item Response Theory (Lord, 1952) yielded similar results: some misconceptions in the DLCI can reliably be predicted by the Race or the Gender of the test taker. The research is significant because it has shown that some misconceptions in a STEM discipline attracted students with similar ethnic backgrounds differently; thus, leading to the existence of some cultural bias in the standardized test. Therefore the study encourages further research in cultural validity in standardized tests. With culturally valid tests, it will be possible to increase the effectiveness of targeted teaching and learning strategies for STEM students from diverse ethnic backgrounds. To some extent, this dissertation has contributed to understanding, better, the gap between high enrollment rates and low graduation rates among African American students and also among other minority students in STEM disciplines.

  18. Translation and validation of the Malay version of the Stroke Knowledge Test.

    Science.gov (United States)

    Sowtali, Siti Noorkhairina; Yusoff, Dariah Mohd; Harith, Sakinah; Mohamed, Monniaty

    2016-04-01

    To date, there is a lack of published studies on assessment tools to evaluate the effectiveness of stroke education programs. This study developed and validated the Malay language version of the Stroke Knowledge Test research instrument. This study involved translation, validity, and reliability phases. The instrument underwent backward and forward translation of the English version into the Malay language. Nine experts reviewed the content for consistency, clarity, difficulty, and suitability for inclusion. Perceived usefulness and utilization were obtained from experts' opinions. Later, face validity assessment was conducted with 10 stroke patients to determine appropriateness of sentences and grammar used. A pilot study was conducted with 41 stroke patients to determine the item analysis and reliability of the translated instrument using the Kuder Richardson 20 or Cronbach's alpha. The final Malay version Stroke Knowledge Test included 20 items with good content coverage, acceptable item properties, and positive expert review ratings. Psychometric investigations suggest that Malay version Stroke Knowledge Test had moderate reliability with Kuder Richardson 20 or Cronbach's alpha of 0.58. Improvement is required for Stroke Knowledge Test items with unacceptable difficulty indices. Overall, the average rating of perceived usefulness and perceived utility of the instruments were both 72.7%, suggesting that reviewers were likely to use the instruments in their facilities. Malay version Stroke Knowledge Test was a valid and reliable tool to assess educational needs and to evaluate stroke knowledge among participants of group-based stroke education programs in Malaysia.

  19. Evaluation of the separate effects tests (SET) validation matrix

    International Nuclear Information System (INIS)

    1996-11-01

    This work is the result of a one year extended mandate which has been given by the CSNI on the request of the PWG 2 and the Task Group on Thermal Hydraulic System Behaviour (TG THSB) in late 1994. The aim was to evaluate the SET validation matrix in order to define the real needs for further experimental work. The statistical evaluation tables of the SET matrix provide an overview of the data base including the parameter ranges covered for each phenomenon and selected parameters, and questions posed to obtain answers concerning the need for additional experimental data with regard to the objective of nuclear power plant safety. A global view of the data base is first presented focussing on areas lacking in data and on hot topics. A new systematic evaluation has been done based on the authors technical judgments and giving evaluation tables. In these tables, global and indicative information are included. Four main parameters have been chosen as the most important and relevant parameters: a state parameter given by the operating pressure of the tests, a flow parameter expressed as mass flux, mass flow rate or volumetric flow rate in the tests, a geometrical parameter provided through a typical dimension expressed by a diameter, an equivalent diameter (hydraulic or heated) or a cross sectional area of the test sections, and an energy or heat transfer parameter given as the fluid temperature, the heat flux or the heat transfer surface temperature of the tests

  20. Victoria Symptom Validity Test performance in children and adolescents with neurological disorders.

    Science.gov (United States)

    Brooks, Brian L

    2012-12-01

    It is becoming increasingly more important to study, use, and promote the utility of measures that are designed to detect non-compliance with testing (i.e., poor effort, symptom non-validity, response bias) as part of neuropsychological assessments with children and adolescents. Several measures have evidence for use in pediatrics, but there is a paucity of published support for the Victoria Symptom Validity Test (VSVT) in this population. The purpose of this study was to examine the performance on the VSVT in a sample of pediatric patients with known neurological disorders. The sample consisted of 100 consecutively referred children and adolescents between the ages of 6 and 19 years (mean = 14.0, SD = 3.1) with various neurological diagnoses. On the VSVT total items, 95% of the sample had performance in the "valid" range, with 5% being deemed "questionable" and 0% deemed "invalid". On easy items, 97% were "valid", 2% were "questionable", and 1% was "invalid." For difficult items, 84% were "valid," 16% were "questionable," and 0% was "invalid." For those patients given two effort measures (i.e., VSVT and Test of Memory Malingering; n = 65), none was identified as having poor test-taking compliance on both measures. VSVT scores were significantly correlated with age, intelligence, processing speed, and functional ratings of daily abilities (attention, executive functioning, and adaptive functioning), but not objective performance on the measure of sustained attention, verbal memory, or visual memory. The VSVT has potential to be used in neuropsychological assessments with pediatric patients.

  1. Cryogenic distribution system for ITER proto-type cryoline test

    International Nuclear Information System (INIS)

    Bhattacharya, R.; Shah, N.; Badgujar, S.; Sarkar, B.

    2012-01-01

    Design validation for ITER cryoline will be carried out by proto-type test on cryoline. The major objectives of the test will be to ensure the mechanical integrity, reliability, thermal stress and heat load as well as checking of assembly and fabrication procedures. The cryogenics system has to satisfy the functional operating scenario of the cryoline. Cryoplant, distribution box (DB) including liquid helium (LHe) tank constitute the cryogenic system for the test. Conceptual system architecture is proposed with a commercially available refrigerator/liquefier and custom designed DB housing cold compressor, cold circulator as well as phase separator with sub-merged heat exchanger. System level optimization, mainly with DB and LHe tank with options, has been studied to minimize the cold power required for the system. Aspen HYSYS is used for the purpose of process simulation. The paper describes the system architecture and the optimized design as well as process simulation with associated results. (author)

  2. Validation of a Spanish version of the Test Your Memory.

    Science.gov (United States)

    Ferrero-Arias, J; Turrión-Rojo, M Á

    2016-01-01

    To validate a Spanish version of the TYM, a self-administered cognitive screening test designed for the detection of Alzheimer's disease and mild cognitive defect. A cross-sectional study was conducted in a neurology outpatient clinic. The TYM was administered to individuals of 50 years o more who came to the clinic for whatever the symptom. Their cognitive state was evaluated regardless of the outcome of TYM. They were categorized into 3 groups: 1) Cognitively normal (739), 2) with mild cognitive impairment (183), 3) with dementia (127). An analysis of items was made and the psychometric properties of the TYM were defined. There was a cross-validation, and the predictive validity of the TYM score, adjusted to the demographic variables, was determined by evaluating their performance in ROC curves. The internal consistency, interobserver reliability, short term and long-term test-retest reliability were adequate. The TYM correlated with the MMSE (r=0.779, Pde Neurología. Published by Elsevier España, S.L.U. All rights reserved.

  3. A Characterization of the Utility of Using Artificial Intelligence to Test Two Artificial Intelligence Systems

    Directory of Open Access Journals (Sweden)

    Jeremy Straub

    2013-05-01

    Full Text Available An artificial intelligence system, designed for operations in a real-world environment faces a nearly infinite set of possible performance scenarios. Designers and developers, thus, face the challenge of validating proper performance across both foreseen and unforeseen conditions, particularly when the artificial intelligence is controlling a robot that will be operating in close proximity, or may represent a danger, to humans. While the manual creation of test cases allows limited testing (perhaps ensuring that a set of foreseeable conditions trigger an appropriate response, this may be insufficient to fully characterize and validate safe system performance. An approach to validating the performance of an artificial intelligence system using a simple artificial intelligence test case producer (AITCP is presented. The AITCP allows the creation and simulation of prospective operating scenarios at a rate far exceeding that possible by human testers. Four scenarios for testing an autonomous navigation control system are presented: single actor in two-dimensional space, multiple actors in two-dimensional space, single actor in three-dimensional space, and multiple actors in three-dimensional space. The utility of using the AITCP is compared to that of human testers in each of these scenarios.

  4. Use of the color trails test as an embedded measure of performance validity.

    Science.gov (United States)

    Henry, George K; Algina, James

    2013-01-01

    One hundred personal injury litigants and disability claimants referred for a forensic neuropsychological evaluation were administered both portions of the Color Trails Test (CTT) as part of a more comprehensive battery of standardized tests. Subjects who failed two or more free-standing tests of cognitive performance validity formed the Failed Performance Validity (FPV) group, while subjects who passed all free-standing performance validity measures were assigned to the Passed Performance Validity (PPV) group. A cutscore of ≥45 seconds to complete Color Trails 1 (CT1) was associated with a classification accuracy of 78%, good sensitivity (66%) and high specificity (90%), while a cutscore of ≥84 seconds to complete Color Trails 2 (CT2) was associated with a classification accuracy of 82%, good sensitivity (74%) and high specificity (90%). A CT1 cutscore of ≥58 seconds, and a CT2 cutscore ≥100 seconds was associated with 100% positive predictive power at base rates from 20 to 50%.

  5. Simulating direct shear tests with the Bullet physics library: A validation study.

    Science.gov (United States)

    Izadi, Ehsan; Bezuijen, Adam

    2018-01-01

    This study focuses on the possible uses of physics engines, and more specifically the Bullet physics library, to simulate granular systems. Physics engines are employed extensively in the video gaming, animation and movie industries to create physically plausible scenes. They are designed to deliver a fast, stable, and optimal simulation of certain systems such as rigid bodies, soft bodies and fluids. This study focuses exclusively on simulating granular media in the context of rigid body dynamics with the Bullet physics library. The first step was to validate the results of the simulations of direct shear testing on uniform-sized metal beads on the basis of laboratory experiments. The difference in the average angle of mobilized frictions was found to be only 1.0°. In addition, a very close match was found between dilatancy in the laboratory samples and in the simulations. A comprehensive study was then conducted to determine the failure and post-failure mechanism. We conclude with the presentation of a simulation of a direct shear test on real soil which demonstrated that Bullet has all the capabilities needed to be used as software for simulating granular systems.

  6. Overview of the system alone and system/CFD coupled calculations of the PHENIX Natural Circulation Test within the THINS project

    Energy Technology Data Exchange (ETDEWEB)

    Pialla, David, E-mail: david.pialla@cea.fr [Commissariat à l’Energie Atomique et aux Energies Alternatives (CEA), DEN/DM2S/STMF, 17 rue des martyrs, 38054 Grenoble Cedex 9 (France); Tenchine, Denis [Commissariat à l’Energie Atomique et aux Energies Alternatives (CEA), DEN/DM2S/STMF, 17 rue des martyrs, 38054 Grenoble Cedex 9 (France); Li, Simon [Commissariat à l’Energie Atomique et aux Energies Alternatives (CEA), DEN/DM2S/STMF, 91191 Gif-sur-Yvette Cedex (France); Gauthe, Paul; Vasile, Alfredo [Commissariat à l’Energie Atomique et aux Energies Alternatives (CEA), DEN/DER/SESI, 13108 Saint Paul Lez Durance Cedex (France); Baviere, Roland; Tauveron, Nicolas; Perdu, Fabien [Commissariat à l’Energie Atomique et aux Energies Alternatives (CEA), DEN/DM2S/STMF, 17 rue des martyrs, 38054 Grenoble Cedex 9 (France); Maas, Ludovic; Cocheme, François [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN/SEMIA/BAST, B.P. 17, 92262 Fontenay-aux-Roses Cedex (France); Huber, Klaus; Cheng, Xu [Karlsruhe Institute of Technology (KIT), Institute of Fusion and Reactor Technology (IFRT), Kaiserstraße 12, Building 07.08, 76131 Karlsruhe (Germany)

    2015-08-15

    Highlights: • The PHENIX natural convection test performed during the end of life tests program. • The calculation with system codes and theirs limits. • The calculation with coupling CFD and system code, which allows better prediction. • The tasks of code validation have been done in the frame of the THINS project. - Abstract: The PHENIX sodium cooled fast reactor started operation in 1973 and was shut down in 2009. Before decommissioning, an ultimate test program was designed and performed to provide valuable data for the development of future sodium cooled fast reactors, as the so-called Astrid prototype in France. Among these ultimate tests, a thermal-hydraulic Natural Convection Test (NCT) was set-up in June 2009. Starting from a reduced power state of 120 MWt, the NCT consists of a loss of the heat sink combined with a reactor scram and a primary pumps trip leading to stabilized natural circulation in the primary sodium system. The thermal-hydraulics innovative system project (THINS project), sponsored by the European Community in the frame of the 7th FP has selected this transient for validation of both stand-alone system code simulations and coupled simulations using system and CFD codes. Participants from three organizations (CEA, IRSN and KIT) have addressed this transient using different system codes (CATHARE, DYN2B and ATHLET) and CFD codes (TRIO-U and OPEN FOAM). The present paper depicts the different modeling approaches, methodologies and compares the numerical results with the available experimental data. Finally, the main lessons learned from the work performed within the THINS project on the PHENIX NCT with respect to code development and validation are summarized.

  7. Validity, Reliability, and Sensitivity of a Volleyball Intermittent Endurance Test.

    Science.gov (United States)

    Rodríguez-Marroyo, Jose A; Medina-Carrillo, Javier; García-López, Juan; Morante, Juan C; Villa, José G; Foster, Carl

    2017-03-01

    To analyze the concurrent and construct validity of a volleyball intermittent endurance test (VIET). The VIET's test-retest reliability and sensitivity to assess seasonal changes was also studied. During the preseason, 71 volleyball players of different competitive levels took part in this study. All performed the VIET and a graded treadmill test with gas-exchange measurement (GXT). Thirty-one of the players performed an additional VIET to analyze the test-retest reliability. To test the VIET's sensitivity, 28 players repeated the VIET and GXT at the end of their season. Significant (P volleyball players.

  8. COMMUNICATIVE VALIDITY OF THE NEW CET-4 LISTENING COMPREHENSION TEST IN CHINA

    Directory of Open Access Journals (Sweden)

    Chao Wang

    2014-07-01

    Full Text Available Abstract: Based on the major dimensions of a communicative language test that Bachman proposed, this paper aims to have an investigation on the validity of the new CET-4 listening subtest in China from a communicative point of view. Both qualitative and quantitative methods are involved in the study. Material analysis falls into qualitative study, including analysis of the CET-4 testing syllabus and eight new CET-4 listening comprehension tests. Students’ scores of two tests and the questionnaires are analyzed quantitatively. Through analysis, it is found that the new CET-4 listening subtest has a high validity and can measure test-takers’ listening ability in real communication. First, the new CET-4 listening subtest has the quality of reliability. Second, the seven listening skills tested in this subtest can measure the communicative language ability required in the testing syllabus. The intra-correlation analysis shows that each part of the new CET-4 listening subtest focuses on different language abilities related to listening. Third, the authenticity of the new CET-4 listening subtest reaches a satisfactory level. The materials chosen in the test cover various topics and genres. Speakers’ pronunciation, tone and speed are in accordance with the real situation. However, some shortcomings also exist in the test design and should be improved later. For example, its limited item types cannot represent the task types in real life, and the actual input is too ideal to be authentic.   Keywords: Communicative language ability, communicative language testing, listening comprehension, test validity

  9. Testing space weather connections in the solar system

    Science.gov (United States)

    Grison, B.; Souček, J.; Krupař, V.; Píša, D.; Santolík, O.; Taubenschuss, U.; Němec, F.

    2017-09-01

    This study aims at testing and validating tools for prediction of the impact of solar events in the vicinity of inner and outer solar system planets using in-situ spacecraft data (primarily MESSENGER, STEREO and ACE, but also VEX and Cassini), remote Jovian observations (Hubble telescope, Nançay decametric array), existing catalogues (HELCATS and Tao et al. (2005)) and the tested propagating models (the ICME radial propagation tool of the CDPP and the 1-D MHD code propagation model presented in Tao et al. (2005)).

  10. Validation of Cardiovascular Parameters during NASA's Functional Task Test

    Science.gov (United States)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, S. H.

    2009-01-01

    Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1, both RR and SBP trended towards preflight

  11. Excellent cross-cultural validity, intra-test reliability and construct validity of the dutch rivermead mobility index in patients after stroke undergoing rehabilitation

    NARCIS (Netherlands)

    Roorda, Leo D.; Green, John; De Kluis, Kiki R. A.; Molenaar, Ivo W.; Bagley, Pam; Smith, Jane; Geurts, Alexander C. H.

    2008-01-01

    Objective: To investigate the cross-cultural validity of international Dutch-English comparisons when using the Dutch Rivermead Mobility Index (RMI), and the intra-test reliability and construct validity of the Dutch RMI. Methods: Cross-cultural validity was studied in a combined data-set of Dutch

  12. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    Science.gov (United States)

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  13. Tests of the data acquisition system and detector control system for the muon chambers of the CMS experiment at the LHC

    CERN Document Server

    Sowa, Michael Christian

    The Phys. Inst. III A of RWTH Aachen University is involved in the development, production and tests of the Drift Tube (DT) muon chambers for the barrel muon system of the CMS detector at the LHC at CERN (Geneva). The thesis describes some test procedures which were developed and performed for the chamber local Data Acquisition (DAQ) system, as well as for parts of the Detector Control System (DCS). The test results were analyzed and discussed. Two main kinds of DAQ tests were done. On the one hand, to compare two different DAQ systems, the chamber signals were split and read out by both systems. This method allowed to validate them by demonstrating, that there were no relevant differences in the measured drift times, generated by the same muon event in the same chamber cells. On the other hand, after the systems were validated, the quality of the data was checked. For this purpose extensive noise studies were performed. The noise dependence on various parameters (threshold, HV) was investigated quantitativel...

  14. Common Data Acquisition Systems (DAS) Software Development for Rocket Propulsion Test (RPT) Test Facilities

    Science.gov (United States)

    Hebert, Phillip W., Sr.; Davis, Dawn M.; Turowski, Mark P.; Holladay, Wendy T.; Hughes, Mark S.

    2012-01-01

    The advent of the commercial space launch industry and NASA's more recent resumption of operation of Stennis Space Center's large test facilities after thirty years of contractor control resulted in a need for a non-proprietary data acquisition systems (DAS) software to support government and commercial testing. The software is designed for modularity and adaptability to minimize the software development effort for current and future data systems. An additional benefit of the software's architecture is its ability to easily migrate to other testing facilities thus providing future commonality across Stennis. Adapting the software to other Rocket Propulsion Test (RPT) Centers such as MSFC, White Sands, and Plumbrook Station would provide additional commonality and help reduce testing costs for NASA. Ultimately, the software provides the government with unlimited rights and guarantees privacy of data to commercial entities. The project engaged all RPT Centers and NASA's Independent Verification & Validation facility to enhance product quality. The design consists of a translation layer which provides the transparency of the software application layers to underlying hardware regardless of test facility location and a flexible and easily accessible database. This presentation addresses system technical design, issues encountered, and the status of Stennis development and deployment.

  15. Ares I-X Flight Test Validation of Control Design Tools in the Frequency-Domain

    Science.gov (United States)

    Johnson, Matthew; Hannan, Mike; Brandon, Jay; Derry, Stephen

    2011-01-01

    A major motivation of the Ares I-X flight test program was to Design for Data, in order to maximize the usefulness of the data recorded in support of Ares I modeling and validation of design and analysis tools. The Design for Data effort was intended to enable good post-flight characterizations of the flight control system, the vehicle structural dynamics, and also the aerodynamic characteristics of the vehicle. To extract the necessary data from the system during flight, a set of small predetermined Programmed Test Inputs (PTIs) was injected directly into the TVC signal. These PTIs were designed to excite the necessary vehicle dynamics while exhibiting a minimal impact on loads. The method is similar to common approaches in aircraft flight test programs, but with unique launch vehicle challenges due to rapidly changing states, short duration of flight, a tight flight envelope, and an inability to repeat any test. This paper documents the validation effort of the stability analysis tools to the flight data which was performed by comparing the post-flight calculated frequency response of the vehicle to the frequency response calculated by the stability analysis tools used to design and analyze the preflight models during the control design effort. The comparison between flight day frequency response and stability tool analysis for flight of the simulated vehicle shows good agreement and provides a high level of confidence in the stability analysis tools for use in any future program. This is true for both a nominal model as well as for dispersed analysis, which shows that the flight day frequency response is enveloped by the vehicle s preflight uncertainty models.

  16. Utility Advanced Turbine Systems (ATS) technology readiness testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The overall objective of the Advanced Turbine System (ATS) Phase 3 Cooperative Agreement between GE and the US Department of Energy (DOE) is the development of the GE 7H and 9H combined cycle power systems. The major effort will be expended on detail design. Validation of critical components and technologies will be performed, including: hot gas path component testing, sub-scale compressor testing, steam purity test trials, and rotational heat transfer confirmation testing. Processes will be developed to support the manufacture of the first system, which was to have been sited and operated in Phase 4 but will now be sited and operated commercially by GE. This change has resulted horn DOE's request to GE for deletion of Phase 4 in favor of a restructured Phase 3 (as Phase 3R) to include fill speed, no load (FSNL) testing of the 7H gas turbine. Technology enhancements that are not required for the first machine design but will be critical for future ATS advances in performance, reliability, and costs will be initiated. Long-term tests of materials to confirm design life predictions will continue. A schematic of the GE H machine is shown.

  17. A Vehicle Management End-to-End Testing and Analysis Platform for Validation of Mission and Fault Management Algorithms to Reduce Risk for NASA's Space Launch System

    Science.gov (United States)

    Trevino, Luis; Johnson, Stephen B.; Patterson, Jonathan; Teare, David

    2015-01-01

    The development of the Space Launch System (SLS) launch vehicle requires cross discipline teams with extensive knowledge of launch vehicle subsystems, information theory, and autonomous algorithms dealing with all operations from pre-launch through on orbit operations. The characteristics of these systems must be matched with the autonomous algorithm monitoring and mitigation capabilities for accurate control and response to abnormal conditions throughout all vehicle mission flight phases, including precipitating safing actions and crew aborts. This presents a large complex systems engineering challenge being addressed in part by focusing on the specific subsystems handling of off-nominal mission and fault tolerance. Using traditional model based system and software engineering design principles from the Unified Modeling Language (UML), the Mission and Fault Management (M&FM) algorithms are crafted and vetted in specialized Integrated Development Teams composed of multiple development disciplines. NASA also has formed an M&FM team for addressing fault management early in the development lifecycle. This team has developed a dedicated Vehicle Management End-to-End Testbed (VMET) that integrates specific M&FM algorithms, specialized nominal and off-nominal test cases, and vendor-supplied physics-based launch vehicle subsystem models. The flexibility of VMET enables thorough testing of the M&FM algorithms by providing configurable suites of both nominal and off-nominal test cases to validate the algorithms utilizing actual subsystem models. The intent is to validate the algorithms and substantiate them with performance baselines for each of the vehicle subsystems in an independent platform exterior to flight software test processes. In any software development process there is inherent risk in the interpretation and implementation of concepts into software through requirements and test processes. Risk reduction is addressed by working with other organizations such as S

  18. Development, Validation and Integration of the ATLAS Trigger System Software in Run 2

    CERN Document Server

    Keyes, Robert; The ATLAS collaboration

    2016-01-01

    The trigger system of the ATLAS detector at the LHC is a combination of hardware, firmware and software, associated to various sub-detectors that must seamlessly cooperate in order to select 1 collision of interest out of every 40,000 delivered by the LHC every millisecond. This talk will discuss the challenges, workflow and organization of the ongoing trigger software development, validation and deployment. This development, from the top level integration and configuration to the individual components responsible for each sub system, is done to ensure that the most up to date algorithms are used to optimize the performance of the experiment. This optimization hinges on the reliability and predictability of the software performance, which is why validation is of the utmost importance. The software adheres to a hierarchical release structure, with newly validated releases propagating upwards. Integration tests are carried out on a daily basis to ensure that the releases deployed to the online trigger farm duri...

  19. Validation of new CFD release by Ground-Coupled Heat Transfer Test Cases

    Directory of Open Access Journals (Sweden)

    Sehnalek Stanislav

    2017-01-01

    Full Text Available In this article is presented validation of ANSYS Fluent with IEA BESTEST Task 34. Article stars with outlook to the topic, afterward are described steady-state cases used for validation. Thereafter is mentioned implementation of these cases on CFD. Article is concluded with presentation of the simulated results with a comparison of those from already validated simulation software by IEA. These validation shows high correlation with an older version of tested ANSYS as well as with other main software. The paper ends by discussion with an outline of future research.

  20. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  1. Ecological validity of the Yo-Yo SFIE2 test

    DEFF Research Database (Denmark)

    Krustrup, Peter; Randers, Morten Bredsgaard; Horton, J

    2012-01-01

    The present study investigated the movement pattern of Portuguese top-level futsal referees (n=16) during competitive games and the ecological validity of the new Yo-Yo Sideways-Forwards Intermittent Endurance level 2 test (Yo-Yo SFIE2). Total distance covered (TD), high-intensity running (HIR...

  2. Validation of a Short Form of an Indecision Test: The Vocational Assessment Test

    Science.gov (United States)

    Picard, France; Frenette, Éric; Guay, Frédéric; Labrosse, Julie

    2015-01-01

    The purpose of this research was to validate the scores of a short form of a new instrument, "l'Épreuve de décision vocationnelle, forme scolaire" (EDV-9S; vocational assessment test), which measures six indecision-related problems (lack of self-knowledge, lack of readiness, lack of method in decision making, lack of information,…

  3. Validation Testing for Automated Solubility Measurement Equipment Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lachut, J. S. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2016-01-11

    Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride did not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.

  4. Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom

    CERN Document Server

    Mainaud Durand, H; Griffet, S; Kemppinen, J; Leuxe, R; Sosin, M

    2011-01-01

    The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies.

  5. Six factors of adult dyslexia assesed by cognitive tests and self-report questions: Very high predictive validity

    NARCIS (Netherlands)

    Tamboer, P.; Vorst, H.C.M.; de Jong, P.F.

    2017-01-01

    The Multiple Diagnostic Digital Dyslexia Test for Adults (MDDDT-A) consists of 12 newly developed tests and self-report questions in the Dutch language. Predictive validity and construct validity were investigated and compared with validity of a standard test battery of dyslexia (STB) in a sample of

  6. A set of pathological tests to validate new finite elements

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    The finite element method entails several approximations. Hence it ... researchers have designed several pathological tests to validate any new finite element. The .... Three dimensional thick shell elements using a hybrid/mixed formu- lation.

  7. WEC-SIM Phase 1 Validation Testing -- Numerical Modeling of Experiments: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ruehl, Kelley; Michelen, Carlos; Bosma, Bret; Yu, Yi-Hsiang

    2016-08-01

    The Wave Energy Converter Simulator (WEC-Sim) is an open-source code jointly developed by Sandia National Laboratories and the National Renewable Energy Laboratory. It is used to model wave energy converters subjected to operational and extreme waves. In order for the WEC-Sim code to be beneficial to the wave energy community, code verification and physical model validation is necessary. This paper describes numerical modeling of the wave tank testing for the 1:33-scale experimental testing of the floating oscillating surge wave energy converter. The comparison between WEC-Sim and the Phase 1 experimental data set serves as code validation. This paper is a follow-up to the WEC-Sim paper on experimental testing, and describes the WEC-Sim numerical simulations for the floating oscillating surge wave energy converter.

  8. Recommendations for elaboration, transcultural adaptation and validation process of tests in Speech, Hearing and Language Pathology.

    Science.gov (United States)

    Pernambuco, Leandro; Espelt, Albert; Magalhães, Hipólito Virgílio; Lima, Kenio Costa de

    2017-06-08

    to present a guide with recommendations for translation, adaptation, elaboration and process of validation of tests in Speech and Language Pathology. the recommendations were based on international guidelines with a focus on the elaboration, translation, cross-cultural adaptation and validation process of tests. the recommendations were grouped into two Charts, one of them with procedures for translation and transcultural adaptation and the other for obtaining evidence of validity, reliability and measures of accuracy of the tests. a guide with norms for the organization and systematization of the process of elaboration, translation, cross-cultural adaptation and validation process of tests in Speech and Language Pathology was created.

  9. Proposal and validation of a clinical trunk control test in individuals with spinal cord injury.

    Science.gov (United States)

    Quinzaños, J; Villa, A R; Flores, A A; Pérez, R

    2014-06-01

    One of the problems that arise in spinal cord injury (SCI) is alteration in trunk control. Despite the need for standardized scales, these do not exist for evaluating trunk control in SCI. To propose and validate a trunk control test in individuals with SCI. National Institute of Rehabilitation, Mexico. The test was developed and later evaluated for reliability and criteria, content, and construct validity. We carried out 531 tests on 177 patients and found high inter- and intra-rater reliability. In terms of criterion validity, analysis of variance demonstrated a statistically significant difference in the test score of patients with adequate or inadequate trunk control according to the assessment of a group of experts. A receiver operating characteristic curve was plotted for optimizing the instrument's cutoff point, which was determined at 13 points, with a sensitivity of 98% and a specificity of 92.2%. With regard to construct validity, the correlation between the proposed test and the spinal cord independence measure (SCIM) was 0.873 (P=0.001) and that with the evolution time was 0.437 (P=0.001). For testing the hypothesis with qualitative variables, the Kruskal-Wallis test was performed, which resulted in a statistically significant difference between the scores in the proposed scale of each group defined by these variables. It was proven experimentally that the proposed trunk control test is valid and reliable. Furthermore, the test can be used for all patients with SCI despite the type and level of injury.

  10. Validation of a clinical critical thinking skills test in nursing

    OpenAIRE

    Shin, Sujin; Jung, Dukyoo; Kim, Sungeun

    2015-01-01

    Purpose: The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. Methods: This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school stud...

  11. Reliability and Validity of the Inline Skating Skill Test

    Directory of Open Access Journals (Sweden)

    Ivan Radman, Lana Ruzic, Viktoria Padovan, Vjekoslav Cigrovski, Hrvoje Podnar

    2016-09-01

    Full Text Available This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male were randomized into two groups (competitive level vs. recreational level. They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]. In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%] and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]. The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2 revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p < 0.01 to complete the test in comparison to recreational-level skaters. Moreover, moderate correlation (ρ = 0.80–0.82; all p < 0.01 was observed between the participant’s self-rating and achieved performance times. In conclusion, the proposed test is a reliable and valid method to evaluate inline skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters.

  12. The bogus taste test: Validity as a measure of laboratory food intake.

    Science.gov (United States)

    Robinson, Eric; Haynes, Ashleigh; Hardman, Charlotte A; Kemps, Eva; Higgs, Suzanne; Jones, Andrew

    2017-09-01

    Because overconsumption of food contributes to ill health, understanding what affects how much people eat is of importance. The 'bogus' taste test is a measure widely used in eating behaviour research to identify factors that may have a causal effect on food intake. However, there has been no examination of the validity of the bogus taste test as a measure of food intake. We conducted a participant level analysis of 31 published laboratory studies that used the taste test to measure food intake. We assessed whether the taste test was sensitive to experimental manipulations hypothesized to increase or decrease food intake. We examined construct validity by testing whether participant sex, hunger and liking of taste test food were associated with the amount of food consumed in the taste test. In addition, we also examined whether BMI (body mass index), trait measures of dietary restraint and over-eating in response to palatable food cues were associated with food consumption. Results indicated that the taste test was sensitive to experimental manipulations hypothesized to increase or decrease food intake. Factors that were reliably associated with increased consumption during the taste test were being male, have a higher baseline hunger, liking of the taste test food and a greater tendency to overeat in response to palatable food cues, whereas trait dietary restraint and BMI were not. These results indicate that the bogus taste test is likely to be a valid measure of food intake and can be used to identify factors that have a causal effect on food intake. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Validation of the computer code system ATHLET / ATHLET-CD. Final report; Validierung des Rechenprogrammsystems ATHLET / ATHLET-CD. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Austregesilo, H.; Bals, C.; Erdmann, W.; Horche, W.; Krzykacz-Hausmann, B.; Pointner, W.; Schoeffel, P.; Skorek, T.; Weber, S.; Wielenberg, A.

    2010-04-15

    In the frame of the reactor safety project RS1173, sponsored by the German Federal Ministry of Economics and Technology, analyses of international integral and separate effects tests have been performed for the validation of the code system ATHLET/ATHLET-CD. The work mainly comprised post-test calculations of selected experiments and the contributions to the working groups accompanying the experimental programs. For the assessment of the thermal-hydraulic models in ATHLET 8 integral tests and 4 separate effect tests have been considered. Together with the corroboration of the existing models, the validation analyses were mainly dedicated to the assessment of the modelling of non-condensable gases and their influence on two-phase natural circulation and on the primary heat removal through steam generators, as well as of the simulation of multi-dimensional flow processes. The validation calculations with respect to the simulation of multi-dimensional one- and two-phase flows aimed to investigate the range of applicability and limitations of the method of parallel channels in connection with the separate momentum equations for water and steam current used in ATHLET as well as to assess the status of the coupled version ATHLET/FLUBOX-3D. The ATHLET-CD validation analyses included the post-test calculations of 9 bundle tests, and was mainly focussed on the assessment of the improved and new models for core degradation, including the models for oxidation, melt formation and relocation for BWR components, as well as of the modelling of fission products and aerosol transport within the primary circuit taking into account chemical reactions within the module SOPHAEROS. As an additional contribution to code validation, the GRS methodology of uncertainty and sensitivity analysis was applied exemplarily to two validation calculations, one with ATHLET and one with ATHLET-CD. The results of these uncertainty analyses endorse the capability of the code system to reproduce

  14. VALIDITY OF THE EATING ATTITUDE TEST AMONG EXERCISERS

    Directory of Open Access Journals (Sweden)

    Hilary Matheson

    2004-12-01

    Full Text Available Theory testing and construct measurement are inextricably linked. To date, no published research has looked at the factorial validity of an existing eating attitude inventory for use with exercisers. The Eating Attitude Test (EAT is a 26-item measure that yields a single index of disordered eating attitudes. The original factor analysis showed three interrelated factors: Dieting behavior (13-items, oral control (7-items, and bulimia nervosa-food preoccupation (6-items. The primary purpose of the study was to examine the factorial validity of the EAT among a sample of exercisers. The second purpose was to investigate relationships between eating attitudes scores and selected psychological constructs. In stage one, 598 regular exercisers completed the EAT. Confirmatory factor analysis (CFA was used to test the single-factor, a three-factor model, and a four-factor model, which distinguished bulimia from food pre-occupation. CFA of the single-factor model (RCFI = 0.66, RMSEA = 0.10, the three-factor-model (RCFI = 0.74; RMSEA = 0.09 showed poor model fit. There was marginal fit for the 4-factor model (RCFI = 0.91, RMSEA = 0.06. Results indicated five-items showed poor factor loadings. After these 5-items were discarded, the three models were re-analyzed. CFA results indicated that the single-factor model (RCFI = 0.76, RMSEA = 0.10 and three-factor model (RCFI = 0.82, RMSEA = 0.08 showed poor fit. CFA results for the four-factor model showed acceptable fit indices (RCFI = 0.98, RMSEA = 0.06. Stage two explored relationships between EAT scores, mood, self-esteem, and motivational indices toward exercise in terms of self-determination, enjoyment and competence. Correlation results indicated that depressed mood scores positively correlated with bulimia and dieting scores. Further, dieting was inversely related with self-determination toward exercising. Collectively, findings suggest that a 21-item four-factor model shows promising validity coefficients

  15. Independent verification and validation testing of the FLASH computer code, Versiion 3.0

    International Nuclear Information System (INIS)

    Martian, P.; Chung, J.N.

    1992-06-01

    Independent testing of the FLASH computer code, Version 3.0, was conducted to determine if the code is ready for use in hydrological and environmental studies at various Department of Energy sites. This report describes the technical basis, approach, and results of this testing. Verification tests, and validation tests, were used to determine the operational status of the FLASH computer code. These tests were specifically designed to test: correctness of the FORTRAN coding, computational accuracy, and suitability to simulating actual hydrologic conditions. This testing was performed using a structured evaluation protocol which consisted of: blind testing, independent applications, and graduated difficulty of test cases. Both quantitative and qualitative testing was performed through evaluating relative root mean square values and graphical comparisons of the numerical, analytical, and experimental data. Four verification test were used to check the computational accuracy and correctness of the FORTRAN coding, and three validation tests were used to check the suitability to simulating actual conditions. These tests cases ranged in complexity from simple 1-D saturated flow to 2-D variably saturated problems. The verification tests showed excellent quantitative agreement between the FLASH results and analytical solutions. The validation tests showed good qualitative agreement with the experimental data. Based on the results of this testing, it was concluded that the FLASH code is a versatile and powerful two-dimensional analysis tool for fluid flow. In conclusion, all aspects of the code that were tested, except for the unit gradient bottom boundary condition, were found to be fully operational and ready for use in hydrological and environmental studies

  16. Testing Strategies and Methodologies for the Max Launch Abort System

    Science.gov (United States)

    Schaible, Dawn M.; Yuchnovicz, Daniel E.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Engineering and Safety Center (NESC) was tasked to develop an alternate, tower-less launch abort system (LAS) as risk mitigation for the Orion Project. The successful pad abort flight demonstration test in July 2009 of the "Max" launch abort system (MLAS) provided data critical to the design of future LASs, while demonstrating the Agency s ability to rapidly design, build and fly full-scale hardware at minimal cost in a "virtual" work environment. Limited funding and an aggressive schedule presented a challenge for testing of the complex MLAS system. The successful pad abort flight demonstration test was attributed to the project s systems engineering and integration process, which included: a concise definition of, and an adherence to, flight test objectives; a solid operational concept; well defined performance requirements, and a test program tailored to reducing the highest flight test risks. The testing ranged from wind tunnel validation of computational fluid dynamic simulations to component ground tests of the highest risk subsystems. This paper provides an overview of the testing/risk management approach and methodologies used to understand and reduce the areas of highest risk - resulting in a successful flight demonstration test.

  17. Development and validation of the coronary heart disease scale under the system of quality of life instruments for chronic diseases QLICD-CHD: combinations of classical test theory and Generalizability Theory.

    Science.gov (United States)

    Wan, Chonghua; Li, Hezhan; Fan, Xuejin; Yang, Ruixue; Pan, Jiahua; Chen, Wenru; Zhao, Rong

    2014-06-04

    Quality of life (QOL) for patients with coronary heart disease (CHD) is now concerned worldwide with the specific instruments being seldom and no one developed by the modular approach. This paper is aimed to develop the CHD scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-CHD) by the modular approach and validate it by both classical test theory and Generalizability Theory. The QLICD-CHD was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, pre-testing and quantitative statistical procedures. 146 inpatients with CHD were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t-tests and also G studies and D studies of Genralizability Theory analysis. Multi-trait scaling analysis, correlation and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. The internal consistency α and test-retest reliability coefficients (Pearson r and Intra-class correlations ICC) for the overall instrument and all domains were higher than 0.70 and 0.80 respectively; The overall and all domains except for social domain had statistically significant changes after treatments with moderate effect size SRM (standardized response mea) ranging from 0.32 to 0.67. G-coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-CHD has good validity, reliability, and moderate responsiveness and some highlights, and can be used as the quality of life instrument for patients with CHD. However, in order to obtain better reliability, the numbers of items for social domain should be increased or the items' quality, not quantity, should be

  18. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    Science.gov (United States)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  19. NASA Double Asteroid Redirection Test (DART) Trajectory Validation and Robutness

    Science.gov (United States)

    Sarli, Bruno V.; Ozimek, Martin T.; Atchison, Justin A.; Englander, Jacob A.; Barbee, Brent W.

    2017-01-01

    The Double Asteroid Redirection Test (DART) mission will be the first to test the concept of a kinetic impactor. Several studies have been made on asteroid redirection and impact mitigation, however, to this date no mission tested the proposed concepts. An impact study on a representative body allows the measurement of the effects on the target's orbit and physical structure. With this goal, DART's objective is to verify the effectiveness of the kinetic impact concept for planetary defense. The spacecraft uses solar electric propulsion to escape Earth, fly by (138971) 2001 CB21 for impact rehearsal, and impact Didymos-B, the secondary body of the binary (65803) Didymos system. This work focuses on the heliocentric transfer design part of the mission with the validation of the baseline trajectory, performance comparison to other mission objectives, and assessment of the baseline robustness to missed thrust events. Results show a good performance of the selected trajectory for different mission objectives: latest possible escape date, maximum kinetic energy on impact, shortest possible time of flight, and use of an Earth swing-by. The baseline trajectory was shown to be robust to a missed thrust with 1% of fuel margin being enough to recover the mission for failures of more than 14 days.

  20. A standardized approach to verification and validation to assist in expert system development

    International Nuclear Information System (INIS)

    Hines, J.W.; Hajek, B.K.; Miller, D.W.; Haas, M.A.

    1992-01-01

    For the past six years, the Nuclear Engineering Program's Artificial Intelligence (AI) Group at The Ohio State University has been developing an integration of expert systems to act as an aid to nuclear power plant operators. This Operator Advisor consists of four modules that monitor plant parameters, detect deviations from normality, diagnose the root cause of the abnormality, manage procedures to effectively respond to the abnormality, and mitigate its consequences. Recently Ohio State University received a grant from the Department of Energy's Special Research Grant Program to utilize the methodologies developed for the Operator Advisor for Heavy Water Reactor (HWR) malfunction root cause diagnosis. To aid in the development of this new system, a standardized Verification and Validation (V ampersand V) approach is being implemented. Its primary functions are to guide the development of the expert system and to ensure that the end product fulfills the initial objectives. The development process has been divided into eight life-cycle V ampersand V phases from concept to operation and maintenance. Each phase has specific V ampersand V tasks to be performed to ensure a quality end product. Four documents are being used to guide development. The Software Verification and Validation Plan (SVVP) outlines the V ampersand V tasks necessary to verify the product at the end of each software development phase, and to validate that the end product complies with the established software and system requirements and meets the needs of the user. The Software Requirements Specification (SRS) documents the essential requirements of the system. The Software Design Description (SDD) represents these requirements with a specific design. And lastly, the Software Test Document establishes a testing methodology to be used throughout the development life-cycle. 10 refs., 1 fig

  1. Validation of a Video-based Game-Understanding Test Procedure in Badminton.

    Science.gov (United States)

    Blomqvist, Minna T.; Luhtanen, Pekka; Laakso, Lauri; Keskinen, Esko

    2000-01-01

    Reports the development and validation of video-based game-understanding tests in badminton for elementary and secondary students. The tests included different sequences that simulated actual game situations. Players had to solve tactical problems by selecting appropriate solutions and arguments for their decisions. Results suggest that the test…

  2. Validation of an automatic system (DoubleCage) for detecting the location of animals during preference tests.

    Science.gov (United States)

    Tsai, P P; Nagelschmidt, N; Kirchner, J; Stelzer, H D; Hackbarth, H

    2012-01-01

    Preference tests have often been performed for collecting information about animals' acceptance of environmental refinement objects. In numerous published studies animals were individually tested during preference experiments, as it is difficult to observe group-housed animals with an automatic system. Thus, videotaping is still the most favoured method for observing preferences of socially-housed animals. To reduce the observation workload and to be able to carry out preference testing of socially-housed animals, an automatic recording system (DoubleCage) was developed for determining the location of group-housed animals in a preference test set-up. This system is able to distinguish the transition of individual animals between two cages and to record up to 16 animals at the same time (four animals per cage). The present study evaluated the reliability of the DoubleCage system. The data recorded by the DoubleCage program and the data obtained by human observation were compared. The measurements of the DoubleCage system and manual observation of the videotapes are comparable and significantly correlated (P animals and a considerable reduction of animal observation time.

  3. The Validity of Value-Added Estimates from Low-Stakes Testing Contexts: The Impact of Change in Test-Taking Motivation and Test Consequences

    Science.gov (United States)

    Finney, Sara J.; Sundre, Donna L.; Swain, Matthew S.; Williams, Laura M.

    2016-01-01

    Accountability mandates often prompt assessment of student learning gains (e.g., value-added estimates) via achievement tests. The validity of these estimates have been questioned when performance on tests is low stakes for students. To assess the effects of motivation on value-added estimates, we assigned students to one of three test consequence…

  4. Validation of the Stroke Specific Quality of Life Scale (SS-QOL): test of reliability and validity of the Danish version (SS-QOL-DK).

    Science.gov (United States)

    Muus, Ingrid; Williams, Linda S; Ringsberg, Karin C

    2007-07-01

    To test the reliability and validity of the Danish version of the Stroke Specific Quality of Life Scale version 2.0 (SS-QOL-DK), an instrument for evaluation of health-related quality of life. A correlational study. A stroke unit that provides acute care and rehabilitation for stroke patients in Frederiksborg County, Denmark. One hundred and fifty-two stroke survivors participated; 24 of these performed test-retest. Questionnaires were sent out and returned by mail. A subsequent telephone interview assessed functional level and missing items. Test-retest was measured using Spearman's r, internal consistency was estimated using Cronbach's alpha, and evaluation of floor and ceiling values in proportion of minimum and maximum scores. Construct validity was assessed by comparing patients' scores on the SS-QOL-DK with those obtained by other test methods: Beck's Depression Index, the General Health Survey Short Form 36 (SF-36), the Barthel Index and the National Institutes of Health Stroke Scale, evaluating shared variance using coefficient of determination, r2. Comparing groups with known scores assessed known-group validity. Convergent and discriminant validity were assessed. Test-retest of SS-QOL-DK showed excellent stability, Spearman's r = 0.65-0.99. Internal consistency for all domains showed Cronbach's alpha = 0.81-0.94. Missing items rate was 1.0%. Most SS-QOL-DK domains showed moderately shared variance with similar domains of other test methods, r2 = 0.03-0.62. Groups with known differences showed statistically significant difference in scores. Item-to-scale correlation coefficients of 0.37-0.88 supported convergent validity. SS-QOL-DK is a reliable and valid instrument for measuring self-reported health-related quality of life on group level among people with mild to moderate stroke.

  5. Simple shoulder test and Oxford Shoulder Score: Persian translation and cross-cultural validation.

    Science.gov (United States)

    Naghdi, Soofia; Nakhostin Ansari, Noureddin; Rustaie, Nilufar; Akbari, Mohammad; Ebadi, Safoora; Senobari, Maryam; Hasson, Scott

    2015-12-01

    To translate, culturally adapt, and validate the simple shoulder test (SST) and Oxford Shoulder Score (OSS) into Persian language using a cross-sectional and prospective cohort design. A standard forward and backward translation was followed to culturally adapt the SST and the OSS into Persian language. Psychometric properties of floor and ceiling effects, construct convergent validity, discriminant validity, internal consistency reliability, test-retest reliability, standard error of the measurement (SEM), smallest detectable change (SDC), and factor structure were determined. One hundred patients with shoulder disorders and 50 healthy subjects participated in the study. The PSST and the POSS showed no missing responses. No floor or ceiling effects were observed. Both the PSST and POSS detected differences between patients and healthy subjects supporting their discriminant validity. Construct convergent validity was confirmed by a very good correlation between the PSST and POSS (r = 0.68). There was high internal consistency for both the PSST (α = 0.73) and the POSS (α = 0.91 and 0.92). Test-retest reliability with 1-week interval was excellent (ICCagreement = 0.94 for PSST and 0.90 for POSS). Factor analyses demonstrated a three-factor solution for the PSST (49.7 % of variance) and a two-factor solution for the POSS (61.6 % of variance). The SEM/SDC was satisfactory for PSST (5.5/15.3) and POSS (6.8/18.8). The PSST and POSS are valid and reliable outcome measures for assessing functional limitations in Persian-speaking patients with shoulder disorders.

  6. Validation of the Chinese Handwriting Analysis System (CHAS) for primary school students in Hong Kong.

    Science.gov (United States)

    Li-Tsang, Cecilia W P; Wong, Agnes S K; Leung, Howard W H; Cheng, Joyce S; Chiu, Billy H W; Tse, Linda F L; Chung, Raymond C K

    2013-09-01

    There are more children diagnosed with specific learning difficulties in recent years as people are more aware of these conditions. Diagnostic tool has been validated to screen out this condition from the population (SpLD test for Hong Kong children). However, for specific assessment on handwriting problem, there seems a lack of standardized and objective evaluation tool to look into the problems. The objective of this study was to validate the Chinese Handwriting Analysis System (CHAS), which is designed to measure both the process and production of handwriting. The construct validity, convergent validity, internal consistency and test-retest reliability of CHAS was analyzed using the data from 734 grade 1-6 students from 6 primary schools in Hong Kong. Principal Component Analysis revealed that measurements of CHAS loaded into 4 components which accounted for 77.73% of the variance. The correlation between the handwriting accuracy obtained from HAS and eyeballing was r=.73. Cronbach's alpha of all measurement items was .65. Except SD of writing time per character, all the measurement items regarding handwriting speed, handwriting accuracy and pen pressure showed good to excellent test-retest reliability (r=.72-.96), while measurement on the numbers of characters which exceeded grid showed moderate reliability (r=.48). Although there are still ergonomic, biomechanical or unspecified aspects which may not be determined by the system, the CHAS can definitely assist therapists in identifying primary school students with handwriting problems and implement interventions accordingly. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Exploring the reliability and validity of the social-moral awareness test.

    Science.gov (United States)

    Livesey, Alexandra; Dodd, Karen; Pote, Helen; Marlow, Elizabeth

    2012-11-01

    The aim of the study was to explore the validity of the social-moral awareness test (SMAT) a measure designed for assessing socio-moral rule knowledge and reasoning in people with learning disabilities. Comparisons between Theory of Mind and socio-moral reasoning allowed the exploration of construct validity of the tool. Factor structure, reliability and discriminant validity were also assessed. Seventy-one participants with mild-moderate learning disabilities completed the two scales of the SMAT and two False Belief Tasks for Theory of Mind. Reliability of the SMAT was very good, and the scales were shown to be uni-dimensional in factor structure. There was a significant positive relationship between Theory of Mind and both SMAT scales. There is early evidence of the construct validity and reliability of the SMAT. Further assessment of the validity of the SMAT will be required. © 2012 Blackwell Publishing Ltd.

  8. Multiyear Plan for Validation of EnergyPlus Multi-Zone HVAC System Modeling using ORNL's Flexible Research Platform

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bhandari, Mahabir S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); New, Joshua Ryan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-10-01

    This document describes the Oak Ridge National Laboratory (ORNL) multiyear experimental plan for validation and uncertainty characterization of whole-building energy simulation for a multi-zone research facility using a traditional rooftop unit (RTU) as a baseline heating, ventilating, and air conditioning (HVAC) system. The project’s overarching objective is to increase the accuracy of energy simulation tools by enabling empirical validation of key inputs and algorithms. Doing so is required to inform the design of increasingly integrated building systems and to enable accountability for performance gaps between design and operation of a building. The project will produce documented data sets that can be used to validate key functionality in different energy simulation tools and to identify errors and inadequate assumptions in simulation engines so that developers can correct them. ASHRAE Standard 140, Method of Test for the Evaluation of Building Energy Analysis Computer Programs (ASHRAE 2004), currently consists primarily of tests to compare different simulation programs with one another. This project will generate sets of measured data to enable empirical validation, incorporate these test data sets in an extended version of Standard 140, and apply these tests to the Department of Energy’s (DOE) EnergyPlus software (EnergyPlus 2016) to initiate the correction of any significant deficiencies. The fitness-for-purpose of the key algorithms in EnergyPlus will be established and demonstrated, and vendors of other simulation programs will be able to demonstrate the validity of their products. The data set will be equally applicable to validation of other simulation engines as well.

  9. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  10. Performance Validity Testing in Neuropsychology: Methods for Measurement Development and Maximizing Diagnostic Accuracy.

    Science.gov (United States)

    Wodushek, Thomas R; Greher, Michael R

    2017-05-01

    In the first column in this 2-part series, Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review, the authors introduced performance validity tests (PVTs) and their function, provided a justification for why they are necessary, traced their ongoing endorsement by neuropsychological organizations, and described how they are used and interpreted by ever increasing numbers of clinical neuropsychologists. To enhance readers' understanding of these measures, this second column briefly describes common detection strategies used in PVTs as well as the typical methods used to validate new PVTs and determine cut scores for valid/invalid determinations. We provide a discussion of the latest research demonstrating how neuropsychologists can combine multiple PVTs in a single battery to improve sensitivity/specificity to invalid responding. Finally, we discuss future directions for the research and application of PVTs.

  11. Building a Validity Argument for the Test of English as a Foreign Language™

    CERN Document Server

    Chapelle, Carol A; Jamieson, Joan M

    2007-01-01

    Building a Validity Argument for the Test of English as a Foreign Language™ is distinctive in its attempt to develop a coherent story of the rationale for a test or its revision, explain the research and development process, and provide the results of the validation process. This volume is particularly relevant for professionals and graduate students in educational measurement, applied linguistics, and second language acquisition as well as anyone interested in assessment issues.

  12. PWR pressurizer discharge piping system on-site testing

    International Nuclear Information System (INIS)

    Anglaret, G.; Lasne, M.

    1983-08-01

    Framatome PWR systems includes the installation of safety valves and relief valves wich permit the discharge of steam from the pressurizer to the pressurizer relief tank through discharge piping system. Water seal expulsion pluration then depends on valve stem lift dynamics which can vary according to water-stem interaction. In order to approaches the different phenomenons, it was decided to perform a test on a 900 MWe French plant, test wich objectives are: characterize the mechanical response of the discharge piping to validate a mechanical model; open one, two or several valves among the following: one safety valve and three pilot operated relief valves, at a time or sequentially and measure the discharge piping transient response, the support loads, the

  13. Validation of the Hwalek-Sengstock Elder Abuse Screening Test.

    Science.gov (United States)

    Neale, Anne Victoria; And Others

    Elder abuse is recognized as an under-detected and under-reported social problem. Difficulties in detecting elder abuse are compounded by the lack of a standardized, psychometrically valid instrument for case finding. The development of the Hwalek-Sengstock Elder Abuse Screening Test (H-S/EAST) followed a larger effort to identify indicators and…

  14. Construct validity and reliability of automated body reaction test ...

    African Journals Online (AJOL)

    Automated Body Reaction Test (ABRT) is a new device for skills and physical assessment instrument to measure ability on react, move quickly and accurately in accordance with stimulus. A total of 474 subjects aged 7-17 years old were randomly selected for the construct validity (n=330) and reliability (n=144). The ABRT ...

  15. Verification and Validation of Flight-Critical Systems

    Science.gov (United States)

    Brat, Guillaume

    2010-01-01

    For the first time in many years, the NASA budget presented to congress calls for a focused effort on the verification and validation (V&V) of complex systems. This is mostly motivated by the results of the VVFCS (V&V of Flight-Critical Systems) study, which should materialize as a a concrete effort under the Aviation Safety program. This talk will present the results of the study, from requirements coming out of discussions with the FAA and the Joint Planning and Development Office (JPDO) to technical plan addressing the issue, and its proposed current and future V&V research agenda, which will be addressed by NASA Ames, Langley, and Dryden as well as external partners through NASA Research Announcements (NRA) calls. This agenda calls for pushing V&V earlier in the life cycle and take advantage of formal methods to increase safety and reduce cost of V&V. I will present the on-going research work (especially the four main technical areas: Safety Assurance, Distributed Systems, Authority and Autonomy, and Software-Intensive Systems), possible extensions, and how VVFCS plans on grounding the research in realistic examples, including an intended V&V test-bench based on an Integrated Modular Avionics (IMA) architecture and hosted by Dryden.

  16. Development and content validity testing of a comprehensive classification of diagnoses for pediatric nurse practitioners.

    Science.gov (United States)

    Burns, C

    1991-01-01

    Pediatric nurse practitioners (PNPs) need an integrated, comprehensive classification that includes nursing, disease, and developmental diagnoses to effectively describe their practice. No such classification exists. Further, methodologic studies to help evaluate the content validity of any nursing taxonomy are unavailable. A conceptual framework was derived. Then 178 diagnoses from the North American Nursing Diagnosis Association (NANDA) 1986 list, selected diagnoses from the International Classification of Diseases, the Diagnostic and Statistical Manual, Third Revision, and others were selected. This framework identified and listed, with definitions, three domains of diagnoses: Developmental Problems, Diseases, and Daily Living Problems. The diagnoses were ranked using a 4-point scale (4 = highly related to 1 = not related) and were placed into the three domains. The rating scale was assigned by a panel of eight expert pediatric nurses. Diagnoses that were assigned to the Daily Living Problems domain were then sorted into the 11 Functional Health patterns described by Gordon (1987). Reliability was measured using proportions of agreement and Kappas. Content validity of the groups created was measured using indices of content validity and average congruency percentages. The experts used a new method to sort the diagnoses in a new way that decreased overlaps among the domains. The Developmental and Disease domains were judged reliable and valid. The Daily Living domain of nursing diagnoses showed marginally acceptable validity with acceptable reliability. Six Functional Health Patterns were judged reliable and valid, mixed results were determined for four categories, and the Coping/Stress Tolerance category was judged reliable but not valid using either test. There were considerable differences between the panel's, Gordon's (1987), and NANDA's clustering of NANDA diagnoses. This study defines the diagnostic practice of nurses from a holistic, patient

  17. Validity and Reliability of Surface Electromyography Measurements from a Wearable Athlete Performance System

    Directory of Open Access Journals (Sweden)

    Scott K. Lynn, Casey M. Watkins, Megan A. Wong, Katherine Balfany, Daniel F. Feeney

    2018-06-01

    Full Text Available The Athos ® wearable system integrates surface electromyography (sEMG electrodes into the construction of compression athletic apparel. The Athos system reduces the complexity and increases the portability of collecting EMG data and provides processed data to the end user. The objective of the study was to determine the reliability and validity of Athos as compared with a research grade sEMG system. Twelve healthy subjects performed 7 trials on separate days (1 baseline trial and 6 repeated trials. In each trial subjects wore the wearable sEMG system and had a research grade sEMG system’s electrodes placed just distal on the same muscle, as close as possible to the wearable system’s electrodes. The muscles tested were the vastus lateralis (VL, vastus medialis (VM, and biceps femoris (BF. All testing was done on an isokinetic dynamometer. Baseline testing involved performing isometric 1 repetition maximum tests for the knee extensors and flexors and three repetitions of concentric-concentric knee flexion and extension at MVC for each testing speed: 60, 180, and 300 deg/sec. Repeated trials 2-7 each comprised 9 sets where each set included three repetitions of concentric-concentric knee flexion-extension. Each repeated trial (2-7 comprised one set at each speed and percent MVC (50%, 75%, 100% combination. The wearable system and research grade sEMG data were processed using the same methods and aligned in time. The amplitude metrics calculated from the sEMG for each repetition were the peak amplitude, sum of the linear envelope, and 95th percentile. Validity results comprise two main findings. First, there is not a significant effect of system (Athos or research grade system on the repetition amplitude metrics (95%, peak, or sum. Second, the relationship between torque and sEMG is not significantly different between Athos and the research grade system. For reliability testing, the variation across trials and averaged across speeds was 0.8%, 7

  18. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  19. Laser system for testing radiation imaging detector circuits

    Science.gov (United States)

    Zubrzycka, Weronika; Kasinski, Krzysztof

    2015-09-01

    Performance and functionality of radiation imaging detector circuits in charge and position measurement systems need to meet tight requirements. It is therefore necessary to thoroughly test sensors as well as read-out electronics. The major disadvantages of using radioactive sources or particle beams for testing are high financial expenses and limited accessibility. As an alternative short pulses of well-focused laser beam are often used for preliminary tests. There are number of laser-based devices available on the market, but very often their applicability in this field is limited. This paper describes concept, design and validation of laser system for testing silicon sensor based radiation imaging detector circuits. The emphasis is put on keeping overall costs low while achieving all required goals: mobility, flexible parameters, remote control and possibility of carrying out automated tests. The main part of the developed device is an optical pick-up unit (OPU) used in optical disc drives. The hardware includes FPGA-controlled circuits for laser positioning in 2 dimensions (horizontal and vertical), precision timing (frequency and number) and amplitude (diode current) of short ns-scale (3.2 ns) light pulses. The system is controlled via USB interface by a dedicated LabVIEW-based application enabling full manual or semi-automated test procedures.

  20. Sensing System for Salinity Testing Using Laser-induced Graphene Sensors

    KAUST Repository

    Nag, Anindya

    2017-08-05

    The paper presents the development and implementation of a low-cost salinity sensing system. Commercial polymer films were laser ablated at specific conditions to form graphene-based sensors on flexible Kapton substrates. Sodium chloride was considered as the primary constituent for testing due to its prominent presence in water bodies. The sensor was characterized by testing different concentrations of sodium chloride. A standard curve was developed to perform real-time testing with a sample taken from sea water of unknown concentration. The sensitivity and resolution of these graphene sensors for the experimental solutions were 1.07Ω/ppm and 1ppm respectively. The developed system was validated by testing it with a real sample and cross checking it on the calibration curve. The signal conditioning circuit was further enhanced by embedding a microcontroller to the designed system. The obtained results did provide a platform for implementation of a low-cost salinity sensing system that could be used in marine applications.

  1. Sensing System for Salinity Testing Using Laser-induced Graphene Sensors

    KAUST Repository

    Nag, Anindya; Mukhopadhyay, Subhas Chandra; Kosel, Jü rgen

    2017-01-01

    The paper presents the development and implementation of a low-cost salinity sensing system. Commercial polymer films were laser ablated at specific conditions to form graphene-based sensors on flexible Kapton substrates. Sodium chloride was considered as the primary constituent for testing due to its prominent presence in water bodies. The sensor was characterized by testing different concentrations of sodium chloride. A standard curve was developed to perform real-time testing with a sample taken from sea water of unknown concentration. The sensitivity and resolution of these graphene sensors for the experimental solutions were 1.07Ω/ppm and 1ppm respectively. The developed system was validated by testing it with a real sample and cross checking it on the calibration curve. The signal conditioning circuit was further enhanced by embedding a microcontroller to the designed system. The obtained results did provide a platform for implementation of a low-cost salinity sensing system that could be used in marine applications.

  2. Laboratory results of the AOF system testing

    Science.gov (United States)

    Kolb, Johann; Madec, Pierre-Yves; Arsenault, Robin; Oberti, Sylvain; Paufique, Jérôme; La Penna, Paolo; Ströbele, Stefan; Donaldson, Robert; Soenke, Christian; Suárez Valles, Marcos; Kiekebusch, Mario; Argomedo, Javier; Le Louarn, Miska; Vernet, Elise; Haguenauer, Pierre; Duhoux, Philippe; Aller-Carpentier, Emmanuel; Valenzuela, Jose Javier; Guerra, Juan Carlos

    2016-07-01

    For two years starting in February 2014, the AO modules GRAAL for HAWK-I and GALACSI for MUSE of the Adaptive Optics Facility project have undergone System Testing at ESO's Headquarters. They offer four different modes: NGS SCAO, LGS GLAO in the IR, LGS GLAO and LTAO in the visible. A detailed characterization of those modes was made possible by the existence of ASSIST, a test bench emulating an adaptive VLT including the Deformable Secondary Mirror, a star simulator and turbulence generator and a VLT focal plane re-imager. This phase aimed at validating all the possible components and loops of the AO modules before installation at the actual VLT that comprises the added complexity of real LGSs, a harsher non-reproducible environment and the adaptive telescope control. In this paper we present some of the major results obtained and challenges encountered during the phase of System Tests, like the preparation of the Acquisition sequence, the testing of the Jitter loop, the performance optimization in GLAO and the offload of low-order modes from the DSM to the telescope (restricted to the M2 hexapod). The System Tests concluded with the successful acceptance, shipping, installation and first commissioning of GRAAL in 2015 as well as the acceptance and shipping of GALACSI, ready for installation and commissioning early 2017.

  3. Expert system validation in prolog

    Science.gov (United States)

    Stock, Todd; Stachowitz, Rolf; Chang, Chin-Liang; Combs, Jacqueline

    1988-01-01

    An overview of the Expert System Validation Assistant (EVA) is being implemented in Prolog at the Lockheed AI Center. Prolog was chosen to facilitate rapid prototyping of the structure and logic checkers and since February 1987, we have implemented code to check for irrelevance, subsumption, duplication, deadends, unreachability, and cycles. The architecture chosen is extremely flexible and expansible, yet concise and complementary with the normal interactive style of Prolog. The foundation of the system is in the connection graph representation. Rules and facts are modeled as nodes in the graph and arcs indicate common patterns between rules. The basic activity of the validation system is then a traversal of the connection graph, searching for various patterns the system recognizes as erroneous. To aid in specifying these patterns, a metalanguage is developed, providing the user with the basic facilities required to reason about the expert system. Using the metalanguage, the user can, for example, give the Prolog inference engine the goal of finding inconsistent conclusions among the rules, and Prolog will search the graph intantiations which can match the definition of inconsistency. Examples of code for some of the checkers are provided and the algorithms explained. Technical highlights include automatic construction of a connection graph, demonstration of the use of metalanguage, the A* algorithm modified to detect all unique cycles, general-purpose stacks in Prolog, and a general-purpose database browser with pattern completion.

  4. Comprehensive validation scheme for in situ fiber optics dissolution method for pharmaceutical drug product testing.

    Science.gov (United States)

    Mirza, Tahseen; Liu, Qian Julie; Vivilecchia, Richard; Joshi, Yatindra

    2009-03-01

    There has been a growing interest during the past decade in the use of fiber optics dissolution testing. Use of this novel technology is mainly confined to research and development laboratories. It has not yet emerged as a tool for end product release testing despite its ability to generate in situ results and efficiency improvement. One potential reason may be the lack of clear validation guidelines that can be applied for the assessment of suitability of fiber optics. This article describes a comprehensive validation scheme and development of a reliable, robust, reproducible and cost-effective dissolution test using fiber optics technology. The test was successfully applied for characterizing the dissolution behavior of a 40-mg immediate-release tablet dosage form that is under development at Novartis Pharmaceuticals, East Hanover, New Jersey. The method was validated for the following parameters: linearity, precision, accuracy, specificity, and robustness. In particular, robustness was evaluated in terms of probe sampling depth and probe orientation. The in situ fiber optic method was found to be comparable to the existing manual sampling dissolution method. Finally, the fiber optic dissolution test was successfully performed by different operators on different days, to further enhance the validity of the method. The results demonstrate that the fiber optics technology can be successfully validated for end product dissolution/release testing. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association

  5. SPENT NUCLEAR FUEL (SNF) PROJECT CANISTER STORAGE BUILDING (CSB) MULTI CANISTER OVERPACK (MCO) SAMPLING SYSTEM VALIDATION (OCRWM)

    International Nuclear Information System (INIS)

    BLACK, D.M.; KLEM, M.J.

    2003-01-01

    Approximately 400 Multi-canister overpacks (MCO) containing spent nuclear fuel are to be interim stored at the Canister Storage Building (CSB). Several MCOs (monitored MCOs) are designated to be gas sampled periodically at the CSB sampling/weld station (Bader 2002a). The monitoring program includes pressure, temperature and gas composition measurements of monitored MCOs during their first two years of interim storage at the CSB. The MCO sample cart (CART-001) is used at the sampling/weld station to measure the monitored MCO gas temperature and pressure, obtain gas samples for laboratory analysis and refill the monitored MCO with high purity helium as needed. The sample cart and support equipment were functionally and operationally tested and validated before sampling of the first monitored MCO (H-036). This report documents the results of validation testing using training MCO (TR-003) at the CSB. Another report (Bader 2002b) documents the sample results from gas sampling of the first monitored MCO (H-036). Validation testing of the MCO gas sampling system showed the equipment and procedure as originally constituted will satisfactorily sample the first monitored MCO. Subsequent system and procedural improvements will provide increased flexibility and reliability for future MCO gas sampling. The physical operation of the sampling equipment during testing provided evidence that theoretical correlation factors for extrapolating MCO gas composition from sample results are unnecessarily conservative. Empirically derived correlation factors showed adequate conservatism and support use of the sample system for ongoing monitored MCO sampling

  6. Fundamentals of endoscopic surgery: creation and validation of the hands-on test.

    Science.gov (United States)

    Vassiliou, Melina C; Dunkin, Brian J; Fried, Gerald M; Mellinger, John D; Trus, Thadeus; Kaneva, Pepa; Lyons, Calvin; Korndorffer, James R; Ujiki, Michael; Velanovich, Vic; Kochman, Michael L; Tsuda, Shawn; Martinez, Jose; Scott, Daniel J; Korus, Gary; Park, Adrian; Marks, Jeffrey M

    2014-03-01

    The Fundamentals of Endoscopic Surgery™ (FES) program consists of online materials and didactic and skills-based tests. All components were designed to measure the skills and knowledge required to perform safe flexible endoscopy. The purpose of this multicenter study was to evaluate the reliability and validity of the hands-on component of the FES examination, and to establish the pass score. Expert endoscopists identified the critical skill set required for flexible endoscopy. They were then modeled in a virtual reality simulator (GI Mentor™ II, Simbionix™ Ltd., Airport City, Israel) to create five tasks and metrics. Scores were designed to measure both speed and precision. Validity evidence was assessed by correlating performance with self-reported endoscopic experience (surgeons and gastroenterologists [GIs]). Internal consistency of each test task was assessed using Cronbach's alpha. Test-retest reliability was determined by having the same participant perform the test a second time and comparing their scores. Passing scores were determined by a contrasting groups methodology and use of receiver operating characteristic curves. A total of 160 participants (17 % GIs) performed the simulator test. Scores on the five tasks showed good internal consistency reliability and all had significant correlations with endoscopic experience. Total FES scores correlated 0.73, with participants' level of endoscopic experience providing evidence of their validity, and their internal consistency reliability (Cronbach's alpha) was 0.82. Test-retest reliability was assessed in 11 participants, and the intraclass correlation was 0.85. The passing score was determined and is estimated to have a sensitivity (true positive rate) of 0.81 and a 1-specificity (false positive rate) of 0.21. The FES hands-on skills test examines the basic procedural components required to perform safe flexible endoscopy. It meets rigorous standards of reliability and validity required for high

  7. Construct validity of the Free and Cued Selective Reminding Test in older adults with memory complaints.

    Science.gov (United States)

    Clerici, Francesca; Ghiretti, Roberta; Di Pucchio, Alessandra; Pomati, Simone; Cucumo, Valentina; Marcone, Alessandra; Vanacore, Nicola; Mariani, Claudio; Cappa, Stefano Francesco

    2017-06-01

    The Free and Cued Selective Reminding Test (FCSRT) is the memory test recommended by the International Working Group on Alzheimer's disease (AD) for the detection of amnestic syndrome of the medial temporal type in prodromal AD. Assessing the construct validity and internal consistency of the Italian version of the FCSRT is thus crucial. The FCSRT was administered to 338 community-dwelling participants with memory complaints (57% females, age 74.5 ± 7.7 years), including 34 with AD, 203 with Mild Cognitive Impairment, and 101 with Subjective Memory Impairment. Internal Consistency was estimated using Cronbach's alpha coefficient. To assess convergent validity, five FCSRT scores (Immediate Free Recall, Immediate Total Recall, Delayed Free Recall, Delayed Total Recall, and Index of Sensitivity of Cueing) were correlated with three well-validated memory tests: Story Recall, Rey Auditory Verbal Learning test, and Rey Complex Figure (RCF) recall (partial correlation analysis). To assess divergent validity, a principal component analysis (an exploratory factor analysis) was performed including, in addition to the above-mentioned memory tasks, the following tests: Word Fluencies, RCF copy, Clock Drawing Test, Trail Making Test, Frontal Assessment Battery, Raven Coloured Progressive Matrices, and Stroop Colour-Word Test. Cronbach's alpha coefficients for immediate recalls (IFR and ITR) and delayed recalls (DFR and DTR) were, respectively, .84 and .81. All FCSRT scores were highly correlated with those of the three well-validated memory tests. The factor analysis showed that the FCSRT does not load on the factors saturated by non-memory tests. These findings indicate that the FCSRT has a good internal consistency and has an excellent construct validity as an episodic memory measure. © 2015 The British Psychological Society.

  8. Design and Validation Testing of TruckScan to Assay Large Sacks of Fukushima Radioactive Debris on a Truck

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Atsuo [Canberra-Japan (Japan); Bronson, Frazier [Canberra Industries Inc. (United States)

    2015-07-01

    As a result of the March 2011 earthquake and resulting tsunami in Japan, there was a serious accident at the Fukushima Dai-ichi Nuclear Power Plant. This accident has contaminated soil and vegetation in a wide area around the plant. Decontamination projects over the last 4 years have resulted in large numbers of 1 cubic meter canvas bags of debris, commonly called Super Sacks [SS]. These are currently stored nearby where they were generated, but starting in 2015, they will be moved to various Interim Storage Facilities [ISF]. Trucks will typically carry 8-20 of these SSs. When the trucks arrive at the ISF they need to be rapidly sorted into groups according to radioactivity level, for efficient subsequent processing. Canberra Industries, Inc. [CI] has designed a new truck monitoring system 'TruckScan' for use at these ISFs. The TruckScan system must measure the entire truck loaded with multiple closely packed SSs, and generate a nuclide specific assay report showing the radioactivity in each individual SS. The Canberra-Japan office, along with Obayashi Corporation have performed validation testing to demonstrate to the regulatory authorities that the proposed technique was sufficiently accurate. These validation tests were conducted at a temporary storage area in Fukushima prefecture. Decontaminated waste of various representative types and of various levels of radioactivity was gathered and mixed to create homogeneous volumes. These volumes were sampled multiple times and assayed with laboratory HPGe detectors to determine the reference concentration of each pile. Multiple SSs were loaded from each pile. Some of the SSs were filled 50% full, others 75% full, and others 100% full, to represent the typical loading configuration of the existing SSs in the field. The content of the SSs are either sand, soil, or vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. These SSs with known concentrations of Cs-134 and Cs-137 were then loaded onto trucks in

  9. Design and Validation Testing of TruckScan to Assay Large Sacks of Fukushima Radioactive Debris on a Truck

    International Nuclear Information System (INIS)

    Suzuki, Atsuo; Bronson, Frazier

    2015-01-01

    As a result of the March 2011 earthquake and resulting tsunami in Japan, there was a serious accident at the Fukushima Dai-ichi Nuclear Power Plant. This accident has contaminated soil and vegetation in a wide area around the plant. Decontamination projects over the last 4 years have resulted in large numbers of 1 cubic meter canvas bags of debris, commonly called Super Sacks [SS]. These are currently stored nearby where they were generated, but starting in 2015, they will be moved to various Interim Storage Facilities [ISF]. Trucks will typically carry 8-20 of these SSs. When the trucks arrive at the ISF they need to be rapidly sorted into groups according to radioactivity level, for efficient subsequent processing. Canberra Industries, Inc. [CI] has designed a new truck monitoring system 'TruckScan' for use at these ISFs. The TruckScan system must measure the entire truck loaded with multiple closely packed SSs, and generate a nuclide specific assay report showing the radioactivity in each individual SS. The Canberra-Japan office, along with Obayashi Corporation have performed validation testing to demonstrate to the regulatory authorities that the proposed technique was sufficiently accurate. These validation tests were conducted at a temporary storage area in Fukushima prefecture. Decontaminated waste of various representative types and of various levels of radioactivity was gathered and mixed to create homogeneous volumes. These volumes were sampled multiple times and assayed with laboratory HPGe detectors to determine the reference concentration of each pile. Multiple SSs were loaded from each pile. Some of the SSs were filled 50% full, others 75% full, and others 100% full, to represent the typical loading configuration of the existing SSs in the field. The content of the SSs are either sand, soil, or vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. These SSs with known concentrations of Cs-134 and Cs-137 were then loaded onto trucks in

  10. Development and validation of the irritable bowel syndrome scale under the system of quality of life instruments for chronic diseases QLICD-IBS: combinations of classical test theory and generalizability theory.

    Science.gov (United States)

    Lei, Pingguang; Lei, Guanghe; Tian, Jianjun; Zhou, Zengfen; Zhao, Miao; Wan, Chonghua

    2014-10-01

    This paper is aimed to develop the irritable bowel syndrome (IBS) scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-IBS) by the modular approach and validate it by both classical test theory and generalizability theory. The QLICD-IBS was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, and quantitative statistical procedures. One hundred twelve inpatients with IBS were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability, and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t tests and also G studies and D studies of generalizability theory analysis. Multi-trait scaling analysis, correlation, and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. Test-retest reliability coefficients (Pearson r and intra-class correlation (ICC)) for the overall score and all domains were higher than 0.80; the internal consistency α for all domains at two measurements were higher than 0.70 except for the social domain (0.55 and 0.67, respectively). The overall score and scores for all domains/facets had statistically significant changes after treatments with moderate or higher effect size standardized response mean (SRM) ranging from 0.72 to 1.02 at domain levels. G coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-IBS has good validity, reliability, responsiveness, and some highlights and can be used as the quality of life instrument for patients with IBS.

  11. Computational Design and Experimental Validation of New Thermal Barrier Systems

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Shengmin; Yang, Shizhong; Khosravi, Ebrahim

    2011-12-31

    This project (10/01/2010-9/30/2013), “Computational Design and Experimental Validation of New Thermal Barrier Systems”, originates from Louisiana State University (LSU) Mechanical Engineering Department and Southern University (SU) Department of Computer Science. This proposal will directly support the technical goals specified in DE-FOA-0000248, Topic Area 3: Turbine Materials, by addressing key technologies needed to enable the development of advanced turbines and turbine-based systems that will operate safely and efficiently using coal-derived synthesis gases. We will develop novel molecular dynamics method to improve the efficiency of simulation on novel TBC materials; we will perform high performance computing (HPC) on complex TBC structures to screen the most promising TBC compositions; we will perform material characterizations and oxidation/corrosion tests; and we will demonstrate our new Thermal barrier coating (TBC) systems experimentally under Integrated gasification combined cycle (IGCC) environments. The durability of the coating will be examined using the proposed High Temperature/High Pressure Durability Test Rig under real syngas product compositions.

  12. The TALL-3D facility design and commissioning tests for validation of coupled STH and CFD codes

    Energy Technology Data Exchange (ETDEWEB)

    Grishchenko, Dmitry, E-mail: dmitry@safety.sci.kth.se; Jeltsov, Marti, E-mail: marti@safety.sci.kth.se; Kööp, Kaspar, E-mail: kaspar@safety.sci.kth.se; Karbojian, Aram, E-mail: karbojan@kth.se; Villanueva, Walter, E-mail: walter@safety.sci.kth.se; Kudinov, Pavel, E-mail: pavel@safety.sci.kth.se

    2015-08-15

    Highlights: • Design of a heavy liquid thermal-hydraulic loop for CFD/STH code validation. • Description of the loop instrumentation and assessment of measurement error. • Experimental data from forced to natural circulation transient. - Abstract: Application of coupled CFD (Computational Fluid Dynamics) and STH (System Thermal Hydraulics) codes is a prerequisite for computationally affordable and sufficiently accurate prediction of thermal-hydraulics of complex systems. Coupled STH and CFD codes require validation for understanding and quantification of the sources of uncertainties in the code prediction. TALL-3D is a liquid Lead Bismuth Eutectic (LBE) loop developed according to the requirements for the experimental data for validation of coupled STH and CFD codes. The goals of the facility design are to provide (i) mutual feedback between natural circulation in the loop and complex 3D mixing and stratification phenomena in the pool-type test section, (ii) a possibility to validate standalone STH and CFD codes for each subsection of the facility, and (iii) sufficient number of experimental data to separate the process of input model calibration and code validation. Description of the facility design and its main components, approach to estimation of experimental uncertainty and calibration of model input parameters that are not directly measured in the experiment are discussed in the paper. First experimental data from the forced to natural circulation transient is also provided in the paper.

  13. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    Science.gov (United States)

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. [Validation of three screening tests used for early detection of cervical cancer].

    Science.gov (United States)

    Rodriguez-Reyes, Esperanza Rosalba; Cerda-Flores, Ricardo M; Quiñones-Pérez, Juan M; Cortés-Gutiérrez, Elva I

    2008-01-01

    to evaluate the validity (sensitivity, specificity, and accuracy) of three screening methods used in the early detection of the cervical carcinoma versus the histopathology diagnosis. a selected sample of 107 women attended in the Opportune Detection of Cervicouterine Cancer Program in the Hospital de Zona 46, Instituto Mexicano del Seguro Social in Durango, during the 2003 was included. The application of Papa-nicolaou, acetic acid test, and molecular detection of human papillomavirus, and histopatholgy diagnosis were performed in all the patients at the time of the gynecological exam. The detection and tipification of the human papillomavirus was performed by polymerase chain reaction (PCR) and analysis of polymorphisms of length of restriction fragments (RFLP). Histopathology diagnosis was considered the gold standard. The evaluation of the validity was carried out by the Bayesian method for diagnosis test. the positive cases for acetic acid test, Papanicolaou, and PCR were 47, 22, and 19. The accuracy values were 0.70, 0.80 and 0.99, respectively. since the molecular method showed a greater validity in the early detection of the cervical carcinoma we considered of vital importance its implementation in suitable programs of Opportune Detection of Cervicouterino Cancer Program in Mexico. However, in order to validate this conclusion, cross-sectional studies in different region of country must be carried out.

  15. Construct Validity and Test-Retest Reliability of the Climbing Stairs Questionnaire in Lower-Limb Amputees

    NARCIS (Netherlands)

    de Laat, Fred A.; Rommers, Gerardus M.; Geertzen, Jan H.; Roorda, Leo D.

    de Laat FA, Rommers GM, Geertzen JH, Roorda LD. Construct validity and test-retest reliability of the Climbing Stairs Questionnaire in lower-limb amputees. Arch Phys Med Rehabil 2010;91:1396-401. Objective: To investigate the construct validity and test-retest reliability of the Climbing Stairs

  16. Lay out, test verification and in orbit performance of HELIOS a temperature control system

    Science.gov (United States)

    Brungs, W.

    1975-01-01

    HELIOS temperature control system is described. The main design features and the impact of interactions between experiment, spacecraft system, and temperature control system requirements on the design are discussed. The major limitations of the thermal design regarding a closer sun approach are given and related to test experience and performance data obtained in orbit. Finally the validity of the test results achieved with prototype and flight spacecraft is evaluated by comparison between test data, orbit temperature predictions and flight data.

  17. Computer system validation: an overview of official requirements and standards.

    Science.gov (United States)

    Hoffmann, A; Kähny-Simonius, J; Plattner, M; Schmidli-Vckovski, V; Kronseder, C

    1998-02-01

    A brief overview of the relevant documents for companies in the pharmaceutical industry, which are to be taken into consideration to fulfil computer system validation requirements, is presented. We concentrate on official requirements and valid standards in the USA, European Community and Switzerland. There are basically three GMP-guidelines. their interpretations by the associations of interests like APV and PDA as well as the GAMP Suppliers Guide. However, the three GMP-guidelines imply the same philosophy about computer system validation. They describe more a what-to-do approach for validation, whereas the GAMP Suppliers Guide describes a how-to-do validation. Nevertheless, they do not contain major discrepancies.

  18. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  19. UTILITY ADVANCED TURBINE SYSTEMS(ATS) TECHNOLOGY READINESS TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth A. Yackly

    2001-06-01

    The following paper provides an overview of GE's H System{trademark} technology, and specifically, the design, development, and test activities associated with the DOE Advanced Turbine Systems (ATS) program. There was intensive effort expended in bringing this revolutionary advanced technology program to commercial reality. In addition to describing the magnitude of performance improvement possible through use of H System{trademark} technology, this paper discusses the technological milestones during the development of the first 9H (50Hz) and 7H (60 Hz) gas turbines. To illustrate the methodical product development strategy used by GE, this paper discusses several technologies that were essential to the introduction of the H System{trademark}. Also included are analyses of the series of comprehensive tests of materials, components and subsystems that necessarily preceded full scale field testing of the H System{trademark}. This paper validates one of the basic premises with which GE started the H System{trademark} development program: exhaustive and elaborate testing programs minimized risk at every step of this process, and increase the probability of success when the H System{trademark} is introduced into commercial service. In 1995, GE, the world leader in gas turbine technology for over half a century, in conjunction with the DOE National Energy Technology Laboratory's ATS program, introduced its new generation of gas turbines. This H System{trademark} technology is the first gas turbine ever to achieve the milestone of 60% fuel efficiency. Because fuel represents the largest individual expense of running a power plant, an efficiency increase of even a single percentage point can substantially reduce operating costs over the life of a typical gas-fired, combined-cycle plant in the 400 to 500 megawatt range. The H System{trademark} is not simply a state-of-the-art gas turbine. It is an advanced, integrated, combined-cycle system in which every

  20. Test of Achievement in Quantitative Economics for Secondary Schools: Construction and Validation Using Item Response Theory

    Science.gov (United States)

    Eleje, Lydia I.; Esomonu, Nkechi P. M.

    2018-01-01

    A Test to measure achievement in quantitative economics among secondary school students was developed and validated in this study. The test is made up 20 multiple choice test items constructed based on quantitative economics sub-skills. Six research questions guided the study. Preliminary validation was done by two experienced teachers in…

  1. Validity and Reliability of Published Comprehensive Theory of Mind Tests for Normal Preschool Children: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Seyyede Zohreh Ziatabar Ahmadi

    2015-12-01

    Full Text Available Objective: Theory of mind (ToM or mindreading is an aspect of social cognition that evaluates mental states and beliefs of oneself and others. Validity and reliability are very important criteria when evaluating standard tests; and without them, these tests are not usable. The aim of this study was to systematically review the validity and reliability of published English comprehensive ToM tests developed for normal preschool children.Method: We searched MEDLINE (PubMed interface, Web of Science, Science direct, PsycINFO, and also evidence base Medicine (The Cochrane Library databases from 1990 to June 2015. Search strategy was Latin transcription of ‘Theory of Mind’ AND test AND children. Also, we manually studied the reference lists of all final searched articles and carried out a search of their references. Inclusion criteria were as follows: Valid and reliable diagnostic ToM tests published from 1990 to June 2015 for normal preschool children; and exclusion criteria were as follows: the studies that only used ToM tests and single tasks (false belief tasks for ToM assessment and/or had no description about structure, validity or reliability of their tests. Methodological quality of the selected articles was assessed using the Critical Appraisal Skills Programme (CASP.Result: In primary searching, we found 1237 articles in total databases. After removing duplicates and applying all inclusion and exclusion criteria, we selected 11 tests for this systematic review. Conclusion: There were a few valid, reliable and comprehensive ToM tests for normal preschool children. However, we had limitations concerning the included articles. The defined ToM tests were different in populations, tasks, mode of presentations, scoring, mode of responses, times and other variables. Also, they had various validities and reliabilities. Therefore, it is recommended that the researchers and clinicians select the ToM tests according to their psychometric

  2. Development and validation of a theoretical test in non-anaesthesiologist-administered propofol sedation for gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Jensen, Jeppe Thue; Savran, Mona Meral; Møller, Ann Merete

    2016-01-01

    OBJECTIVE: Safety with non-anaesthesiologist-administered propofol sedation (NAAP) during gastrointestinal (GI) endoscopy is related to theoretical knowledge. A summative testing of knowledge before attempting supervised nurse-administered propofol sedation (NAPS) in the clinic is advised. The aims...... of this study were to develop a theoretical test about propofol sedation, to gather validity evidence for the test and to measure the effect of a NAPS-specific training course. MATERIAL AND METHODS: A three-phased psychometric study on multiple choice questionnaire (MCQ) test development, gathering of validity......% increase; p = 0.001 and 0.001, respectively). CONCLUSIONS: Data supported the validity of the developed MCQ test. The NAPS-specific course with pre-course testing adds theoretical knowledge to already well-prepared participants....

  3. Integrated System Validation of Barakah Nuclear Power Plant in UAE for The Human Factor Engineering

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Munsoo [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    APR1400 simulator has been developed based on the state-of-the-art object-oriented simulation technology of TH(Thermo-Hydraulic) and Reactor Core model, which is applied for the first time in the our country and for the exportation, to well simulate characteristics of APR1400. Barakah unit 1,2 simulator are constructed and supplied with this type simulator model. Integrated system validation was performed using a simulator to verify the HFE(Human Factor Engineering) design of the MCR(Maim Control Room) for instrumentation and control system validation of the UAE nuclear power plant. APR1400 for the Barakah unit 1,2 has many specific features such as digital I and C, and digitalized main control room (MCR) design. From January 2016 to February, during six weeks, the tests carried out three times repeatedly and the various proposals for ergonomical satisfactation were derived. However, the HFE errors that cause significant change of validation target for APR1400 MCR design safety fidelity wasn't found. This has resulted in the conclusion to prove the stability of the basic design of APR1400 MCR. In the future, using the simulator derives the HFE requirements of the MCR systems and continually improve the simulator will be built in close to real high-fidelity power plant. These Integrated system validations are likely to be a great help in operating safety and preventing human errors by operators. Therefore successful completion of the Integrated System Validation for BNPP simulation will be effective to promotion the distinction of our simulator and APR1400 NPP.

  4. Modelling of the activity system - development of an evaluation method for integrated system validation

    International Nuclear Information System (INIS)

    Norros, Leena; Savioja, Paula

    2004-01-01

    In this paper we present our recent research which focuses on creating an evaluation method for human-system interfaces of complex systems. The method is aimed for use in the validation of modernised nuclear power plant (NPP) control rooms, and other complex systems with high reliability requirements. The task in validation is to determine whether the human-system functions safely and effectively. This question can be operationalized to the selection of relevant operational features and their appropriate acceptance criteria. Thus, there is a need to ensure that the results of the evaluation can be generalized so that they serve the purpose of integrated system validation. The definition of the appropriate acceptance criteria provides basis for the judgement of the appropriateness of the performance of the system. We propose that the operational situations and the acceptance criteria should be defined based on modelling of the NPP operation that is comprehended as an activity system. We developed a new core-tasks modelling framework. It is a formative modelling approach that combines causal, functional and understanding explanations of system performance. In this paper we reason how modelling can be used as a medium to determine the validity of the emerging control room system. (Author)

  5. Cyber Security Penetration Test for Digital Safety I and C Systems

    International Nuclear Information System (INIS)

    Lee, C. K.; Kim, D. H.; Kwon, K. C.; Joo, H. K.; Song, J. S.

    2010-01-01

    In the Korea Nuclear I and C Systems Development project the platforms for plant protection systems are developed, which function as a reactor shutdown, actuation of engineered safety features and a control of the related equipment. Those are fully digitalized through the use of safety-grade programmable logic controllers (PLCs) and few types of communication network. However the Regulatory Guide 1.152 (Rev. 02) was published by the U.S. NRC in 2006 and it recommended the application of a cyber security to the safety systems in the Nuclear Power Plant (NPP). Therefore to incorporate the new licensing requirement, a cyber security risk assessment is performed for the platforms. Then the vulnerabilities identified by the risk assessment are validated by penetration test. This paper summarizes test scenario, test results and their incorporation into system design

  6. MARS Validation Plan and Status

    International Nuclear Information System (INIS)

    Ahn, Seung-hoon; Cho, Yong-jin

    2008-01-01

    The KINS Reactor Thermal-hydraulic Analysis System (KINS-RETAS) under development is directed toward a realistic analysis approach of best-estimate (BE) codes and realistic assumptions. In this system, MARS is pivoted to provide the BE Thermal-Hydraulic (T-H) response in core and reactor coolant system to various operational transients and accidental conditions. As required for other BE codes, the qualification is essential to ensure reliable and reasonable accuracy for a targeted MARS application. Validation is a key element of the code qualification, and determines the capability of a computer code in predicting the major phenomena expected to occur. The MARS validation was made by its developer KAERI, on basic premise that its backbone code RELAP5/MOD3.2 is well qualified against analytical solutions, test or operational data. A screening was made to select the test data for MARS validation; some models transplanted from RELAP5, if already validated and found to be acceptable, were screened out from assessment. It seems to be reasonable, but does not demonstrate whether code adequacy complies with the software QA guidelines. Especially there may be much difficulty in validating the life-cycle products such as code updates or modifications. This paper presents the plan for MARS validation, and the current implementation status

  7. The Validity and Responsiveness of Isometric Lower Body Multi-Joint Tests of Muscular Strength: a Systematic Review.

    Science.gov (United States)

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2017-12-01

    Researchers and practitioners working in sports medicine and science require valid tests to determine the effectiveness of interventions and enhance understanding of mechanisms underpinning adaptation. Such decision making is influenced by the supportive evidence describing the validity of tests within current research. The objective of this study is to review the validity of lower body isometric multi-joint tests ability to assess muscular strength and determine the current level of supporting evidence. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed in a systematic fashion to search, assess and synthesize existing literature on this topic. Electronic databases such as Web of Science, CINAHL and PubMed were searched up to 18 March 2015. Potential inclusions were screened against eligibility criteria relating to types of test, measurement instrument, properties of validity assessed and population group and were required to be published in English. The Consensus-based Standards for the Selection of health Measurement Instruments (COSMIN) checklist was used to assess methodological quality and measurement property rating of included studies. Studies rated as fair or better in methodological quality were included in the best evidence synthesis. Fifty-nine studies met the eligibility criteria for quality appraisal. The ten studies that rated fair or better in methodological quality were included in the best evidence synthesis. The most frequently investigated lower body isometric multi-joint tests for validity were the isometric mid-thigh pull and isometric squat. The validity of each of these tests was strong in terms of reliability and construct validity. The evidence for responsiveness of tests was found to be moderate for the isometric squat test and unknown for the isometric mid-thigh pull. No tests using the isometric leg press met the criteria for inclusion in the best evidence synthesis. Researchers and

  8. Understanding Student Teachers' Behavioural Intention to Use Technology: Technology Acceptance Model (TAM) Validation and Testing

    Science.gov (United States)

    Wong, Kung-Teck; Osman, Rosma bt; Goh, Pauline Swee Choo; Rahmat, Mohd Khairezan

    2013-01-01

    This study sets out to validate and test the Technology Acceptance Model (TAM) in the context of Malaysian student teachers' integration of their technology in teaching and learning. To establish factorial validity, data collected from 302 respondents were tested against the TAM using confirmatory factor analysis (CFA), and structural equation…

  9. New Standards for the Validation of EMC Test Sites particularly above 1 GHz

    Directory of Open Access Journals (Sweden)

    S. Battermann

    2005-01-01

    Full Text Available Standards for the validation of alternative test sites with conducting groundplane exist for the frequency range 30-1000 MHz since the end of the eighties. Recently the procedure for fully anechoic rooms (FAR has been included in CISPR 16 after more than 10 years intensive discussion in standards committees (CENELEC, 2002; CISPR, 2004. But there are no standards available for the validation of alternative test sites above 1 GHz. The responsible working group (WG1 in CISPR/A has drawn up the 7th common draft (CD. A CDV will be published in spring 2005. The German standards committee VDE AK 767.4.1 participates in the drafting of the standard. All suggested measurement procedures proposed in the last CDs have been investigated by measurements and theoretical analysis. This contribution describes the basic ideas and problems of the validation procedure of the test site. Furthermore measurement results and numerical calculations will be presented especially for the use of omni-directional antennas.

  10. Verification and Validation of a Fingerprint Image Registration Software

    Directory of Open Access Journals (Sweden)

    Liu Yan

    2006-01-01

    Full Text Available The need for reliable identification and authentication is driving the increased use of biometric devices and systems. Verification and validation techniques applicable to these systems are rather immature and ad hoc, yet the consequences of the wide deployment of biometric systems could be significant. In this paper we discuss an approach towards validation and reliability estimation of a fingerprint registration software. Our validation approach includes the following three steps: (a the validation of the source code with respect to the system requirements specification; (b the validation of the optimization algorithm, which is in the core of the registration system; and (c the automation of testing. Since the optimization algorithm is heuristic in nature, mathematical analysis and test results are used to estimate the reliability and perform failure analysis of the image registration module.

  11. Naturalistic validation of an on-road driving test of older drivers.

    Science.gov (United States)

    Ott, Brian R; Papandonatos, George D; Davis, Jennifer D; Barco, Peggy P

    2012-08-01

    The objective was to compare a standardized road test to naturalistic driving by older people who may have cognitive impairment to define improvements that could potentially enhance the validity of road testing in this population. Road testing has been widely adapted as a tool to assess driving competence of older people who may be at risk for unsafe driving because of dementia; however, the validity of this approach has not been rigorously evaluated. For 2 weeks, 80 older drivers (38 healthy elders and 42 with cognitive impairment) who passed a standardized road test were video recorded in their own vehicles. Using a standardized rating scale, 4 hr of video was rated by a driving instructor. The authors examine weighting of individual road test items to form global impressions and to compare road test and naturalistic driving using factor analyses of these two assessments. The road test score was unidimensional, reflecting a major factor related to awareness of signage and traffic behavior. Naturalistic driving reflected two factors related to lane keeping as well as traffic behavior. Maintenance of proper lane is an important dimension of driving safety that appears to be relatively underemphasized during the highly supervised procedures of the standardized road test. Road testing in this population could be improved by standardized designs that emphasize lane keeping and that include self-directed driving. Additional information should be sought from observers in the community as well as crash evidence when advising older drivers who may be cognitively impaired.

  12. Preliminary Validation and Verification Plan for CAREM Reactor Protection System

    International Nuclear Information System (INIS)

    Fittipaldi, Ana; Maciel Felix

    2000-01-01

    The purpose of this paper, is to present a preliminary validation and verification plan for a particular architecture proposed for the CAREM reactor protection system with software modules (computer based system).These software modules can be either own design systems or systems based in commercial modules such as programmable logic controllers (PLC) redundant of last generation.During this study, it was seen that this plan can also be used as a validation and verification plan of commercial products (COTS, commercial off the shelf) and/or smart transmitters.The software life cycle proposed and its features are presented, and also the advantages of the preliminary validation and verification plan

  13. Criterion and convergent validity of the Montreal cognitive assessment with screening and standardized neuropsychological testing.

    Science.gov (United States)

    Lam, Benjamin; Middleton, Laura E; Masellis, Mario; Stuss, Donald T; Harry, Robin D; Kiss, Alex; Black, Sandra E

    2013-12-01

    To compare the validity of the Montreal Cognitive Assessment (MoCA) with the criterion standard of standardized neuropsychological testing and to compare the convergent validity of the MoCA with that of existing screening tools and global measures of cognition. Cross-sectional observational study. Tertiary care hospital-based cognitive neurology subspecialty clinic. A convenience sample of 107 individuals with mild Alzheimer's disease (AD, n=75) or mild cognitive impairment (MCI, n=32) from the Sunnybrook Dementia Study. In addition to the MoCA, all participants completed the Mini-Mental State Examination (MMSE), the Mattis Dementia Rating Scale (DRS), and detailed neuropsychological testing. Convergent validity was supported, with MoCA scores correlating well with the MMSE (correlation coefficient (r)=0.66, Pvalidity was supported, with MoCA subscores according to cognitive domain correlating well with analogous neuropsychological tests and, in the case of memory (area under the receiver operating characteristic curve (AUC)=0.86), executive (AUC=0.79), and visuospatial function (AUC=0.79), being reasonably sensitive to impairment in those domains. The MoCA is a valid assessment of cognition that shows good agreement with existing screening tools and global measures (convergent validity) and was superior to the MMSE in this regard. The MoCA domain-specific subscores align with performance on more-detailed neuropsychological tests, suggesting not only good criterion validity for the MoCA, but also that it may be useful in guiding further neuropsychological testing. © 2013, Copyright the Authors Journal compilation © 2013, The American Geriatrics Society.

  14. Test suite for the archiver of a SCADA system

    CERN Document Server

    Voitier, Axel

    2009-01-01

    Topic: The group responsible for providing the main control system applications for all machines at CERN has to validate that every piece of the control systems used will be reliable and fully functional when the LHC and its experiments will do collisions of particles. CERN use PVSS from ETM/Siemens for the SCADA part of its control systems. This software has a component dedicated to archive into a centralised Oracle database values and commands of tenth of thousands hardware devices. This component, named RDB, has to be tested and validated in terms of functionality and performance. The need is high for that because archiving is a critical part of the control systems. In case of an incident on one of the machine, it will be unacceptable to not benefit of archiving the machine context at this moment just because of a bug in RDB. Bugs have to be spotted and reported to ETM. Results: The proposed solution is an extensible automatic tester able to evaluate currently around 160 cases of potential bugs. Since the ...

  15. Test-retest reliability and validity of the Sniffin' TOM odor memory test.

    Science.gov (United States)

    Croy, Ilona; Zehner, Cora; Larsson, Maria; Zucco, Gesualdo M; Hummel, Thomas

    2015-03-01

    Few attempts have been made to develop an olfactory test that captures episodic retention of olfactory information. Assessment of episodic odor memory is of particular interest in aging and in the cognitively impaired as both episodic memory deficits and olfactory loss have been targeted as reliable hallmarks of cognitive decline and impending dementia. Here, 96 healthy participants (18-92 years) and an additional 19 older people with mild cognitive impairment were tested (73-82 years). Participants were presented with 8 common odors with intentional encoding instructions that were followed by a yes-no recognition test. After recognition completion, participants were asked to identify all odors by means of free or cued identification. A retest of the odor memory test (Sniffin' TOM = test of odor memory) took place 17 days later. The results revealed satisfactory test-retest reliability (0.70) of odor recognition memory. Both recognition and identification performance were negatively affected by age and more pronounced among the cognitively impaired. In conclusion, the present work presents a reliable, valid, and simple test of episodic odor recognition memory that may be used in clinical groups where both episodic memory deficits and olfactory loss are prevalent preclinically such as Alzheimer's disease. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. The Validity of Graduate Management Admission Test Scores: A Summary of Studies Conducted from 1997 to 2004

    Science.gov (United States)

    Talento-Miller, Eileen; Rudner, Lawrence M.

    2008-01-01

    The validity of Graduate Management Admission Test (GMAT) scores is examined by summarizing 273 studies conducted between 1997 and 2004. Each of the studies was conducted through the Validity Study Service of the test sponsor and contained identical variables and statistical methods. Validity coefficients from each of the studies were corrected…

  17. Recommended Research Directions for Improving the Validation of Complex Systems Models.

    Energy Technology Data Exchange (ETDEWEB)

    Vugrin, Eric D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Trucano, Timothy G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Swiler, Laura Painton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Finley, Patrick D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flanagan, Tatiana Paz [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Naugle, Asmeret Bier [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Tsao, Jeffrey Y. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Verzi, Stephen Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-02-01

    Improved validation for models of complex systems has been a primary focus over the past year for the Resilience in Complex Systems Research Challenge. This document describes a set of research directions that are the result of distilling those ideas into three categories of research -- epistemic uncertainty, strong tests, and value of information. The content of this document can be used to transmit valuable information to future research activities, update the Resilience in Complex Systems Research Challenge's roadmap, inform the upcoming FY18 Laboratory Directed Research and Development (LDRD) call and research proposals, and facilitate collaborations between Sandia and external organizations. The recommended research directions can provide topics for collaborative research, development of proposals, workshops, and other opportunities.

  18. Testing and Validation of the Dynamic Inertia Measurement Method

    Science.gov (United States)

    Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David

    2015-01-01

    The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

  19. Major Results from 1-Train Passive Safety System Tests for the SMART Design with the SMART-ITL Facility

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun-Sik; Bae, Hwang; Ryu, Sung-Uk; Jeon, Byong-Guk; Ruy, Hyobong; Kim, Woo-Shik; Byun, Sun-Joon; Shin, Yong-Cheol; Min, Kyoung-Ho; Yi, Sung-Jae [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    To satisfy the domestic and international needs for nuclear safety improvement after the Fukushima accident, an effort to improve its safety has been studied, and a Passive Safety System (PSS) for SMART has been designed. In addition, an Integral Test Loop for the SMART design (SMART-ITL, or FESTA) has been constructed and it finished its commissioning tests in 2012. Consequently, a set of Design Base Accident (DBA) scenarios have been simulated using SMARTITL. Recently, a test program to validate the performance of the SMART PSS was launched and its scaled-down test facility was additionally installed at the existing SMART-ITL facility. In this paper, the major results from the 1-train passive safety system validation tests with the SMARTITL facility will be summarized. The acquired data will be used to validate the safety analysis code and its related models, to evaluate the performance of SMART PSS, and to provide base data during the application phase of the SDA revision and construction licensing. In this paper, the major results from the validation tests of the SMART passive safety system using a 1-train test facility were summarized. They include a dozen of SMART PSS tests using 1-train SMART PSS tests. From the test results, it was estimated that the SMART PSS has sufficient cooling capability to deal with the SBLOCA scenario of SMART. During the SBLOCA scenario, in the CMT, the water layer inventory was well stratified thermally and the safety injection water was injected efficiently into the RPV from the initial period, and cools down the RCS properly.

  20. The SEP "robot": a valid virtual reality robotic simulator for the Da Vinci Surgical System?

    Science.gov (United States)

    van der Meijden, O A J; Broeders, I A M J; Schijven, M P

    2010-04-01

    The aim of the study was to determine if the concept of face and construct validity may apply to the SurgicalSim Educational Platform (SEP) "robot" simulator. The SEP robot simulator is a virtual reality (VR) simulator aiming to train users on the Da Vinci Surgical System. To determine the SEP's face validity, two questionnaires were constructed. First, a questionnaire was sent to users of the Da Vinci system (reference group) to determine a focused user-group opinion and their recommendations concerning VR-based training applications for robotic surgery. Next, clinical specialists were requested to complete a pre-tested face validity questionnaire after performing a suturing task on the SEP robot simulator. To determine the SEP's construct validity, outcome parameters of the suturing task were compared, for example, relative to participants' endoscopic experience. Correlations between endoscopic experience and outcome parameters of the performed suturing task were tested for significance. On an ordinal five-point, scale the average score for the quality of the simulator software was 3.4; for its hardware, 3.0. Over 80% agreed that it is important to train surgeons and surgical trainees to use the Da Vinci. There was a significant but marginal difference in tool tip trajectory (p = 0.050) and a nonsignificant difference in total procedure time (p = 0.138) in favor of the experienced group. In conclusion, the results of this study reflect a uniform positive opinion using VR training in robotic surgery. Concepts of face and construct validity of the SEP robotic simulator are present; however, these are not strong and need to be improved before implementation of the SEP robotic simulator in its present state for a validated training curriculum to be successful .

  1. Validation Aspects of Water Treatment Systems for Pharmaceutical ...

    African Journals Online (AJOL)

    The goal of conducting validation is to demonstrate that a process, when operated within established limits, produces a product of consistent and specified quality with a high degree of assurance. Validation of water treatment systems is necessary to obtain water with all desired quality attributes. This also provides a ...

  2. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M. H.; Hoozemans, Marco J. M.; Berger, Monique A. M.; van der Slikke, Rienk M. A.; van der Woude, Lucas H. V.; Veeger, Dirkjan (H. E. J)

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  3. The International Experimental Thermal Hydraulic Systems database – TIETHYS: A new NEA validation tool

    Energy Technology Data Exchange (ETDEWEB)

    Rohatgi, Upendra S.

    2018-07-22

    Nuclear reactor codes require validation with appropriate data representing the plant for specific scenarios. The thermal-hydraulic data is scattered in different locations and in different formats. Some of the data is in danger of being lost. A relational database is being developed to organize the international thermal hydraulic test data for various reactor concepts and different scenarios. At the reactor system level, that data is organized to include separate effect tests and integral effect tests for specific scenarios and corresponding phenomena. The database relies on the phenomena identification sections of expert developed PIRTs. The database will provide a summary of appropriate data, review of facility information, test description, instrumentation, references for the experimental data and some examples of application of the data for validation. The current database platform includes scenarios for PWR, BWR, VVER, and specific benchmarks for CFD modelling data and is to be expanded to include references for molten salt reactors. There are place holders for high temperature gas cooled reactors, CANDU and liquid metal reactors. This relational database is called The International Experimental Thermal Hydraulic Systems (TIETHYS) database and currently resides at Nuclear Energy Agency (NEA) of the OECD and is freely open to public access. Going forward the database will be extended to include additional links and data as they become available. https://www.oecd-nea.org/tiethysweb/

  4. [Reliability and validity of the Chinese version on Alcohol Use Disorders Identification Test].

    Science.gov (United States)

    Zhang, C; Yang, G P; Li, Z; Li, X N; Li, Y; Hu, J; Zhang, F Y; Zhang, X J

    2017-08-10

    Objective: To assess the reliability and validity of the Chinese version on Alcohol Use Disorders Identification Test (AUDIT) among medical students in China and to provide correct way of application on the recommended scales. Methods: An E-questionnaire was developed and sent to medical students in five different colleges. Students were all active volunteers to accept the testings. Cronbach's α and split-half reliability were calculated to evaluate the reliability of AUDIT while content, contract, discriminant and convergent validity were performed to measure the validity of the scales. Results: The overall Cronbach's α of AUDIT was 0.782 and the split-half reliability was 0.711. Data showed that the domain Cronbach's α and split-half reliability were 0.796 and 0.794 for hazardous alcohol use, 0.561 and 0.623 for dependence symptoms, and 0.647 and 0.640 for harmful alcohol use. Results also showed that the content validity index on the levels of items I-CVI) were from 0.83 to 1.00, the content validity index of scale level (S-CVI/UA) was 0.90, content validity index of average scale level (S-CVI/Ave) was 0.99 and the content validity ratios (CVR) were from 0.80 to 1.00. The simplified version of AUDIT supported a presupposed three-factor structure which could explain 61.175% of the total variance revealed through exploratory factor analysis. AUDIT semed to have good convergent and discriminant validity, with the success rate of calibration experiment as 100%. Conclusion: AUDIT showed good reliability and validity among medical students in China thus worth for promotion on its use.

  5. Utility advanced turbine systems (ATS) technology readiness testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-15

    The overall objective of the Advanced Turbine System (ATS) Phase 3 Cooperative Agreement between GE and the US Department of Energy (DOE) is the development of a highly efficient, environmentally superior, and cost-competitive utility ATS for base-load utility-scale power generation, the GE 7H (60 Hz) combined cycle power system, and related 9H (50 Hz) common technology. The major effort will be expended on detail design. Validation of critical components and technologies will be performed, including: hot gas path component testing, sub-scale compressor testing, steam purity test trials, and rotational heat transfer confirmation testing. Processes will be developed to support the manufacture of the first system, which was to have been sited and operated in Phase 4 but will now be sited and operated commercially by GE. This change has resulted from DOE's request to GE for deletion of Phase 4 in favor of a restructured Phase 3 (as Phase 3R) to include full speed, no load (FSNL) testing of the 7H gas turbine. Technology enhancements that are not required for the first machine design but will be critical for future ATS advances in performance, reliability, and costs will be initiated. Long-term tests of materials to confirm design life predictions will continue. A schematic of the GE H machine is shown.

  6. [Support of the nursing process through electronic nursing documentation systems (UEPD) – Initial validation of an instrument].

    Science.gov (United States)

    Hediger, Hannele; Müller-Staub, Maria; Petry, Heidi

    2016-01-01

    Electronic nursing documentation systems, with standardized nursing terminology, are IT-based systems for recording the nursing processes. These systems have the potential to improve the documentation of the nursing process and to support nurses in care delivery. This article describes the development and initial validation of an instrument (known by its German acronym UEPD) to measure the subjectively-perceived benefits of an electronic nursing documentation system in care delivery. The validity of the UEPD was examined by means of an evaluation study carried out in an acute care hospital (n = 94 nurses) in German-speaking Switzerland. Construct validity was analyzed by principal components analysis. Initial references of validity of the UEPD could be verified. The analysis showed a stable four factor model (FS = 0.89) scoring in 25 items. All factors loaded ≥ 0.50 and the scales demonstrated high internal consistency (Cronbach's α = 0.73 – 0.90). Principal component analysis revealed four dimensions of support: establishing nursing diagnosis and goals; recording a case history/an assessment and documenting the nursing process; implementation and evaluation as well as information exchange. Further testing with larger control samples and with different electronic documentation systems are needed. Another potential direction would be to employ the UEPD in a comparison of various electronic documentation systems.

  7. Concurrent validation of an inertial measurement system to quantify kicking biomechanics in four football codes.

    Science.gov (United States)

    Blair, Stephanie; Duthie, Grant; Robertson, Sam; Hopkins, William; Ball, Kevin

    2018-05-17

    Wearable inertial measurement systems (IMS) allow for three-dimensional analysis of human movements in a sport-specific setting. This study examined the concurrent validity of a IMS (Xsens MVN system) for measuring lower extremity and pelvis kinematics in comparison to a Vicon motion analysis system (MAS) during kicking. Thirty footballers from Australian football (n = 10), soccer (n = 10), rugby league and rugby union (n = 10) clubs completed 20 kicks across four conditions. Concurrent validity was assessed using a linear mixed-modelling approach, which allowed the partition of between and within-subject variance from the device measurement error. Results were expressed in raw and standardised units for assessments of differences in means and measurement error, and interpreted via non-clinical magnitude-based inferences. Trivial to small differences were found in linear velocities (foot and pelvis), angular velocities (knee, shank and thigh), sagittal joint (knee and hip) and segment angle (shank and pelvis) means (mean difference: 0.2-5.8%) between the IMS and MAS in Australian football, soccer and the rugby codes. Trivial to small measurement errors (from 0.1 to 5.8%) were found between the IMS and MAS in all kinematic parameters. The IMS demonstrated acceptable levels of concurrent validity compared to a MAS when measuring kicking biomechanics across the four football codes. Wearable IMS offers various benefits over MAS, such as, out-of-laboratory testing, larger measurement range and quick data output, to help improve the ecological validity of biomechanical testing and the timing of feedback. The results advocate the use of IMS to quantify biomechanics of high-velocity movements in sport-specific settings. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Test Bed for Safety Assessment of New e-Navigation Systems

    Directory of Open Access Journals (Sweden)

    Axel Hahn

    2014-12-01

    Full Text Available New e-navigation strains require new technologies, new infrastructures and new organizational structures on bridge, on shore as well as in the cloud. Suitable engineering and safety/risk assessment methods facilitate these efforts. Understanding maritime transportation as a sociotechnical system allows the application of system-engineering methods. Formal, simulation based and in situ verification and validation of e-navigation technologies are important methods to obtain system safety and reliability. The modelling and simulation toolset HAGGIS provides methods for system specification and formal risk analysis. It provides a modelling framework for processes, fault trees and generic hazard specification and a physical world and maritime traffic simulation system. HAGGIS is accompanied by the physical test bed LABSKAUS which implements a physical test bed. The test bed provides reference ports and waterways in combination with an experimental Vessel Traffic Services (VTS system and a mobile integrated bridge: This enables in situ experiments for technological evaluation, testing, ground research and demonstration. This paper describes an integrated seamless approach for developing new e-navigation technologies starting with simulation based assessment and ending in physical real world demonstrations

  9. USFDA-GUIDELINE BASED VALIDATION OF TESTING METHOD FOR RIFAMPICIN IN INDONESIAN SERUM SPECIMEN

    Directory of Open Access Journals (Sweden)

    Tri Joko Raharjo

    2010-06-01

    Full Text Available Regarding a new regulation from Indonesia FDA (Badan POM-RI, all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bio-analytical method for certain drug target and group of population. This research report specific validation of bio-analysis of Rifampicin in Indonesian serum specimen in order to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 × 4.6 mm i.d., 5 µm, with a mobile phase composed of KH2PO4 10 mM-Acetonitrile (40:60, v/v and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ was 0.06 µg/mL with dynamic range up to 20 µg/mL (R>0.990. Precision of the method was very good with coefficient of variance (CV 0.58; 7.40 and 5.56% for concentration at 0.06, 5, 15 µg/mL, respectively. Accuracies of the method were 3.22; 1.94; 1.90% for concentration 0.06, 5 and 15 µg/mL respectively. The average recoveries were 97.82, 95.50 and 97.31% for concentration of rifampicin 1, 5 and 5 µg/mL, respectively. The method was also shown reliable result on stability test on freezing-thawing, short-term and long-term stability as well as post preparation stability. Validation result shown that the method was ready to be used for Rifampicin BE testing with Indonesian subject.   Keywords: Rifampicin, Validation, USFDA-Guideline

  10. Compressive strength test for cemented waste forms: validation process

    International Nuclear Information System (INIS)

    Haucz, Maria Judite A.; Candido, Francisco Donizete; Seles, Sandro Rogerio

    2007-01-01

    In the Cementation Laboratory (LABCIM), of the Development Centre of the Nuclear Technology (CNEN/CDTN-MG), hazardous/radioactive wastes are incorporated in cement, to transform them into monolithic products, preventing or minimizing the contaminant release to the environment. The compressive strength test is important to evaluate the cemented product quality, in which it is determined the compression load necessary to rupture the cemented waste form. In LABCIM a specific procedure was developed to determine the compressive strength of cement waste forms based on the Brazilian Standard NBR 7215. The accreditation of this procedure is essential to assure reproductive and accurate results in the evaluation of these products. To achieve this goal the Laboratory personal implemented technical and administrative improvements in accordance with the NBR ISO/IEC 17025 standard 'General requirements for the competence of testing and calibration laboratories'. As the developed procedure was not a standard one the norm ISO/IEC 17025 requests its validation. There are some methodologies to do that. In this paper it is described the current status of the accreditation project, especially the validation process of the referred procedure and its results. (author)

  11. Validity of the Mayer-Salovey-Caruso Emotional Intelligence Test: Youth Version-Research Edition

    Science.gov (United States)

    Peters, Christine; Kranzler, John H.; Rossen, Eric

    2009-01-01

    This study examines the criterion-related validity evidence of scores on the Mayer-Salovey-Caruso Emotional Intelligence Test: Youth Version-Research Version. The authors also investigate the relationship between scores on the MSCEIT-YV and chronological age. Results provide initial support for the construct validity of the MSCEIT-YV but also…

  12. Experimental system description for air-water CCFL tests of the 161-rod FLECHT-SEASET test vessel upper plenum

    International Nuclear Information System (INIS)

    Fogdall, S.P.; Anderson, J.L.

    1983-01-01

    A series of countercurrent flow limiting (CCFL) experiments has been performed by EG and G Idaho, Inc. in the Steam-Air-Water (SAW) test facility at the Idaho National Engineering Laboratory on behalf of the US Nuclear Regulatory Commission (NRC). Tests were performed in a mockup of the vessel for the 161-Rod Systems Effects Test (SET) facility of the FLECHT-SEASET program, conducted by the Westinghouse Electric Corporation. Westinghouse and the NRC will use the test results to provide a CCFL correlation to predict the flooding behavior in the upper plenum of the SET vessel. This paper presents a description of the experimental system and the test conduct, including data validation and uncertainty analysis. The test objectives centered on experimentally obtaining coefficients in the Wallis correlation for flooding with the specific vessel geometry. The test conditions and vessel configuration are described and the design of the test loop, instrumentation, and data acquisition are discussed. The establishment of a test point and the resultant data are described

  13. Convergent and diagnostic validity of STAVUX, a word and pseudoword spelling test for adults.

    Science.gov (United States)

    Östberg, Per; Backlund, Charlotte; Lindström, Emma

    2016-10-01

    Few comprehensive spelling tests are available in Swedish, and none have been validated in adults with reading and writing disorders. The recently developed STAVUX test includes word and pseudoword spelling subtests with high internal consistency and adult norms stratified by education. This study evaluated the convergent and diagnostic validity of STAVUX in adults with dyslexia. Forty-six adults, 23 with dyslexia and 23 controls, took STAVUX together with a standard word-decoding test and a self-rated measure of spelling skills. STAVUX subtest scores showed moderate to strong correlations with word-decoding scores and predicted self-rated spelling skills. Word and pseudoword subtest scores both predicted dyslexia status. Receiver-operating characteristic (ROC) analysis showed excellent diagnostic discriminability. Sensitivity was 91% and specificity 96%. In conclusion, the results of this study support the convergent and diagnostic validity of STAVUX.

  14. Validation of a Wave-Body Interaction Model by Experimental Tests

    DEFF Research Database (Denmark)

    Ferri, Francesco; Kramer, Morten; Pecher, Arthur

    2013-01-01

    Within the wave energy field, numerical simulation has recently acquired a worldwide consent as being a useful tool, besides physical model testing. The main goal of this work is the validation of a numerical model by experimental results. The numerical model is based on a linear wave-body intera...

  15. The HIrisPlex-S system for eye, hair and skin colour prediction from DNA: Introduction and forensic developmental validation.

    Science.gov (United States)

    Chaitanya, Lakshmi; Breslin, Krystal; Zuñiga, Sofia; Wirken, Laura; Pośpiech, Ewelina; Kukla-Bartoszek, Magdalena; Sijen, Titia; Knijff, Peter de; Liu, Fan; Branicki, Wojciech; Kayser, Manfred; Walsh, Susan

    2018-07-01

    Forensic DNA Phenotyping (FDP), i.e. the prediction of human externally visible traits from DNA, has become a fast growing subfield within forensic genetics due to the intelligence information it can provide from DNA traces. FDP outcomes can help focus police investigations in search of unknown perpetrators, who are generally unidentifiable with standard DNA profiling. Therefore, we previously developed and forensically validated the IrisPlex DNA test system for eye colour prediction and the HIrisPlex system for combined eye and hair colour prediction from DNA traces. Here we introduce and forensically validate the HIrisPlex-S DNA test system (S for skin) for the simultaneous prediction of eye, hair, and skin colour from trace DNA. This FDP system consists of two SNaPshot-based multiplex assays targeting a total of 41 SNPs via a novel multiplex assay for 17 skin colour predictive SNPs and the previous HIrisPlex assay for 24 eye and hair colour predictive SNPs, 19 of which also contribute to skin colour prediction. The HIrisPlex-S system further comprises three statistical prediction models, the previously developed IrisPlex model for eye colour prediction based on 6 SNPs, the previous HIrisPlex model for hair colour prediction based on 22 SNPs, and the recently introduced HIrisPlex-S model for skin colour prediction based on 36 SNPs. In the forensic developmental validation testing, the novel 17-plex assay performed in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines, as previously shown for the 24-plex assay. Sensitivity testing of the 17-plex assay revealed complete SNP profiles from as little as 63 pg of input DNA, equalling the previously demonstrated sensitivity threshold of the 24-plex HIrisPlex assay. Testing of simulated forensic casework samples such as blood, semen, saliva stains, of inhibited DNA samples, of low quantity touch (trace) DNA samples, and of artificially degraded DNA samples as well as

  16. Alignment Methods Developed for the Validation of the Thermal and Mechanical Behaviour of the Two Beam Test Modules for the CLIC Project

    CERN Document Server

    Mainaud Durand, Helene; Sosin, Mateusz; Rude, Vivien

    2014-01-01

    CLIC project will consist of more than 20 000 two meters long modules. A test setup made of three modules is being built at CERN to validate the assembly and integration of all components and technical systems and to validate the short range strategy of pre-alignment. The test setup has been installed in a room equipped with a sophisticated system of ventilation able to reproduce the environmental conditions of the CLIC tunnel. Some of the components have been equipped with electrical heaters to simulate the power dissipation, combined with a water cooling system integrated in the RF components. Using these installations, to have a better understanding of the thermal and mechanical behaviour of a module under different operation modes, machine cycles have been simulated; the misalignment of the components and their supports has been observed. This paper describes the measurements methods developed for such a project and the results obtained.

  17. Test-retest reliability, smallest real difference and concurrent validity of six different balance tests on young people with mild to moderate intellectual disability.

    Science.gov (United States)

    Blomqvist, Sven; Wester, Anita; Sundelin, Gunnevi; Rehn, Börje

    2012-12-01

    Some studies have reported that people with intellectual disability may have reduced balance ability compared with the population in general. However, none of these studies involved adolescents, and the reliability and validity of balance tests in this population are not known. The purpose of this study was to examine the reliability of six different balance tests and to investigate their concurrent validity. Test-retest reliability assessment. All subjects were recruited from a special school for people with intellectual disability in Bollnäs, Sweden. Eighty-nine adolescents (35 females and 54 males) with mild to moderate intellectual disability with a mean age of 18 years (range 16 to 20 years). All subjects followed the same test protocol on two occasions within an 11-day period. Balance test performances. Intraclass correlation coefficients greater than 0.80 were achieved for four of the balance tests: Extended Timed Up and Go Test, Modified Functional Reach Test, One-leg Stance Test and Force Platform Test. The smallest real differences ranged from 12% to 40%; less than 20% is considered to be low. Concurrent validity among these balance tests varied between no and low correlation. The results indicate that these tests could be used to evaluate changes in balance ability over time in people with mild to moderate intellectual disability. The low concurrent validity illustrates the importance of knowing more about the influence of various sensory subsystems that are significant for balance among adolescents with intellectual disability. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  18. Measuring right-hemisphere dysfunction in children: validity of two new computer tests

    NARCIS (Netherlands)

    Sips, H.J.W.A.; C.E. Catsman-Berrevoets (Coriene); H.R. van Dongen (Huug); van der Werff, P.J.J.; Brooke, L.J.

    1994-01-01

    textabstractThe validity of two new computer‐mediated tests for the detection of right‐cerebral hemisphere lesions in children–the Right‐hemisphere Dysfunction Test and the Visual Perception Test–was evaluated. Normative data were drawn from a group of 91 children (aged five to 14 years) and 14

  19. Naturalistic Validation of an On-Road Driving Test of Older Drivers

    Science.gov (United States)

    Ott, Brian R.; Papandonatos, George D.; Davis, Jennifer D.; Barco, Peggy P.

    2013-01-01

    Objective The objective was to compare a standardized road test to naturalistic driving by older people who may have cognitive impairment to define improvements that could potentially enhance the validity of road testing in this population. Background Road testing has been widely adapted as a tool to assess driving competence of older people who may be at risk for unsafe driving because of dementia; however, the validity of this approach has not been rigorously evaluated. Method For 2 weeks, 80 older drivers (38 healthy elders and 42 with cognitive impairment) who passed a standardized road test were video recorded in their own vehicles. Using a standardized rating scale, 4 hr of video was rated by a driving instructor. The authors examine weighting of individual road test items to form global impressions and to compare road test and naturalistic driving using factor analyses of these two assessments. Results The road test score was unidimensional, reflecting a major factor related to awareness of signage and traffic behavior. Naturalistic driving reflected two factors related to lane keeping as well as traffic behavior. Conclusion Maintenance of proper lane is an important dimension of driving safety that appears to be relatively underemphasized during the highly supervised procedures of the standardized road test. Application Road testing in this population could be improved by standardized designs that emphasize lane keeping and that include self-directed driving. Additional information should be sought from observers in the community as well as crash evidence when advising older drivers who may be cognitively impaired. PMID:22908688

  20. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    International Nuclear Information System (INIS)

    Garra, B.

    2016-01-01

    Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy

  1. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    Energy Technology Data Exchange (ETDEWEB)

    Garra, B. [FDA, Silver Spring, MD (United States)

    2016-06-15

    Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy

  2. Development and testing of a cross-culturally valid instrument: food-related life style

    DEFF Research Database (Denmark)

    Brunsø, Karen; Grunert, Klaus G.

    1995-01-01

    -culturaly valid way. To this end we have developed a pool of 202 items, collected data in three countries, and have constructed scales based on cross-culturally stable factor patterns. We have then applie set of scales to a fourth country, in order to further test the cross-cultural validity of the instrument....

  3. Automated smartphone audiometry: Validation of a word recognition test app.

    Science.gov (United States)

    Dewyer, Nicholas A; Jiradejvong, Patpong; Henderson Sabes, Jennifer; Limb, Charles J

    2018-03-01

    Develop and validate an automated smartphone word recognition test. Cross-sectional case-control diagnostic test comparison. An automated word recognition test was developed as an app for a smartphone with earphones. English-speaking adults with recent audiograms and various levels of hearing loss were recruited from an audiology clinic and were administered the smartphone word recognition test. Word recognition scores determined by the smartphone app and the gold standard speech audiometry test performed by an audiologist were compared. Test scores for 37 ears were analyzed. Word recognition scores determined by the smartphone app and audiologist testing were in agreement, with 86% of the data points within a clinically acceptable margin of error and a linear correlation value between test scores of 0.89. The WordRec automated smartphone app accurately determines word recognition scores. 3b. Laryngoscope, 128:707-712, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Preliminary Validation of a New Measure of Negative Response Bias: The Temporal Memory Sequence Test.

    Science.gov (United States)

    Hegedish, Omer; Kivilis, Naama; Hoofien, Dan

    2015-01-01

    The Temporal Memory Sequence Test (TMST) is a new measure of negative response bias (NRB) that was developed to enrich the forced-choice paradigm. The TMST does not resemble the common structure of forced-choice tests and is presented as a temporal recall memory test. The validation sample consisted of 81 participants: 21 healthy control participants, 20 coached simulators, and 40 patients with acquired brain injury (ABI). The TMST had high reliability and significantly high positive correlations with the Test of Memory Malingering and Word Memory Test effort scales. Moreover, the TMST effort scales exhibited high negative correlations with the Glasgow Coma Scale, thus validating the previously reported association between probable malingering and mild traumatic brain injury. A suggested cutoff score yielded acceptable classification rates in the ABI group as well as in the simulator and control groups. The TMST appears to be a promising measure of NRB detection, with respectable rates of reliability and construct and criterion validity.

  5. Model validation: a systemic and systematic approach

    International Nuclear Information System (INIS)

    Sheng, G.; Elzas, M.S.; Cronhjort, B.T.

    1993-01-01

    The term 'validation' is used ubiquitously in association with the modelling activities of numerous disciplines including social, political natural, physical sciences, and engineering. There is however, a wide range of definitions which give rise to very different interpretations of what activities the process involves. Analyses of results from the present large international effort in modelling radioactive waste disposal systems illustrate the urgent need to develop a common approach to model validation. Some possible explanations are offered to account for the present state of affairs. The methodology developed treats model validation and code verification in a systematic fashion. In fact, this approach may be regarded as a comprehensive framework to assess the adequacy of any simulation study. (author)

  6. Development and validation of real-time SAFT-UT system for inservice inspection of LWRs

    International Nuclear Information System (INIS)

    Doctor, S.R.; Hall, T.E.; Reid, L.D.; Mart, G.A.

    1988-01-01

    The Pacific Northwest Laboratory is working to design, fabricate, and evaluate a real-time flaw detection and characterization system based on the synthetic aperture focusing technique for ultrasonic testing (SAFT-UT). The system is designed to perform inservice inspection of light-water reactor components. Included objectives of this program for the Nuclear Regulatory Commission are to develop procedures for system calibration and field operation, to validate the system through laboratory and field inspections, and to generate an engineering database to support ASME Code acceptance of the technology. This progress report covers the programmatic work from October 1986 through September 1987. (author)

  7. VALIDITY OF THE MODIFIED CONCONI TEST FOR DETERMINING VENTILATORY THRESHOLD DURING ON-WATER ROWING

    Directory of Open Access Journals (Sweden)

    Jorge Villamil Cabo

    2011-12-01

    Full Text Available The objectives of this study were to design a field test based on the Conconi protocol to determine the ventilatory threshold of rowers and to test its reliability and validity. A group of sixteen oarsmen completed a modified Conconi test for on-water rowing. The reliability of the detection of the heart rate threshold was evaluated using heart rate breaking point in the Conconi test and retest. Heart rate threshold was detected in 88.8% of cases in the test-retest. The validity of the modified Conconi test was evaluated by comparing the heart rate threshold data acquired with that obtained in a ventilatory threshold test (VT2. No significant differences were found for the values of different intensity parameters i.e. heart rate (HR, oxygen consumption (VO2, stroke rate (SR and speed (S between the heart rate threshold and the ventilatory threshold, (170.9 ± 6.8 vs. 169.3 ± 6.4 beats·min-1; 42.0 ± 8.6 vs. 43.5 ± 8.3 ml·kg-1·min-1; 25.8 ± 3.3 vs. 27.0 ± 3.2 strokes·min-1 and 14.4 ± 0.8 vs. 14.6 ± 0.8 km·h-1. The differences in averages obtained in the Conconi test-retest were small with a low standard error of the mean. The reliability data between the Conconi test-retest showed low coefficients of variations (CV and high intraclass correlation coefficients (ICC. The total errors for the Conconi test-retest are low for the measured variables (1.31 HR, 0.87 VO2, 0.65 SR, and 0.1 S. The Bland- Altman's method for analysis validity showed a strong concordance according to the analyzed variables. We conclude that the modified Conconi test for on-water rowing is a valid and reliable method for the determination of the second ventilatory threshold (VT2.

  8. The validated hypoallergenic cosmetics rating system: its 30-year evolution and effect on the prevalence of cosmetic reactions.

    Science.gov (United States)

    Verallo-Rowell, Vermén M

    2011-01-01

    The validated hypoallergenic (vh) rating system was initiated in 1988 to try to objectively validate the "hypoallergenic" claim in cosmetics. To show how the system rates cosmetic hypoallergenicity and to compare the prevalence of cosmetic contact dermatitis (CCD) among users of regular cosmetics versus cosmetics with high VH numbers. (1) Made a VH list based on top allergens from patch-test results published by the North American Contact Dermatitis Group (NACDG) and the European Surveillance System on Contact Allergies (ESSCA); (2) reviewed global regulatory, cosmetic, drug, packaging, and manufacturing practices to show how allergens may contaminate products; (3) compared cosmetic ingredients lists against the VH list to obtain the VH rating (the more allergens absent, the higher the VH rating); and (4) obtained CCD prevalence among users of regular cosmetics versus users of cosmetics with high VH ratings. (1) Two VH lists (1988, 2003) included only cosmetic allergens in the NACDG surveys, the third (2007) included cosmetic and potential contaminant noncosmetic allergens, and the fourth (2010) adds ESSCA patch-test surveys. (2) CCD prevalence is 0.05 to 0.12% (average, 0.08%) among users of cosmetics with high VH ratings versus 2.4 to 36.3% among users of regular cosmetics. The VH rating system is shown to objectively validate the hypoallergenic cosmetics claim.

  9. Validation of an Instrument to Measure High School Students' Attitudes toward Fitness Testing

    Science.gov (United States)

    Mercier, Kevin; Silverman, Stephen

    2014-01-01

    Purpose: The purpose of this investigation was to develop an instrument that has scores that are valid and reliable for measuring students' attitudes toward fitness testing. Method: The method involved the following steps: (a) an elicitation study, (b) item development, (c) a pilot study, and (d) a validation study. The pilot study included 427…

  10. The Signal Validation method of Digital Process Instrumentation System on signal conditioner for SMART

    International Nuclear Information System (INIS)

    Moon, Hee Gun; Park, Sang Min; Kim, Jung Seon; Shon, Chang Ho; Park, Heui Youn; Koo, In Soo

    2005-01-01

    The function of PIS(Process Instrumentation System) for SMART is to acquire the process data from sensor or transmitter. The PIS consists of signal conditioner, A/D converter, DSP(Digital Signal Process) and NIC(Network Interface Card). So, It is fully digital system after A/D converter. The PI cabinet and PDAS(Plant Data Acquisition System) in commercial plant is responsible for data acquisition of the sensor or transmitter include RTD, TC, level, flow, pressure and so on. The PDAS has the software that processes each sensor data and PI cabinet has the signal conditioner, which is need for maintenance and test. The signal conditioner has the potentiometer to adjust the span and zero for test and maintenance. The PIS of SMART also has the signal conditioner which has the span and zero adjust same as the commercial plant because the signal conditioner perform the signal condition for AD converter such as 0∼10Vdc. But, To adjust span and zero is manual test and calibration. So, This paper presents the method of signal validation and calibration, which is used by digital feature in SMART. There are I/E(current to voltage), R/E(resistor to voltage), F/E(frequency to voltage), V/V(voltage to voltage). Etc. In this paper show only the signal validation and calibration about I/E converter that convert level, pressure, flow such as 4∼20mA into signal for AD conversion such as 0∼10Vdc

  11. Modeling and experimental validation of a Hybridized Energy Storage System for automotive applications

    Science.gov (United States)

    Fiorenti, Simone; Guanetti, Jacopo; Guezennec, Yann; Onori, Simona

    2013-11-01

    This paper presents the development and experimental validation of a dynamic model of a Hybridized Energy Storage System (HESS) consisting of a parallel connection of a lead acid (PbA) battery and double layer capacitors (DLCs), for automotive applications. The dynamic modeling of both the PbA battery and the DLC has been tackled via the equivalent electric circuit based approach. Experimental tests are designed for identification purposes. Parameters of the PbA battery model are identified as a function of state of charge and current direction, whereas parameters of the DLC model are identified for different temperatures. A physical HESS has been assembled at the Center for Automotive Research The Ohio State University and used as a test-bench to validate the model against a typical current profile generated for Start&Stop applications. The HESS model is then integrated into a vehicle simulator to assess the effects of the battery hybridization on the vehicle fuel economy and mitigation of the battery stress.

  12. Development and validation of an OECD reproductive toxicity test guideline with the mudsnail Potamopyrgus antipodarum (Mollusca, Gastropoda).

    Science.gov (United States)

    Ruppert, Katharina; Geiß, Cornelia; Askem, Clare; Benstead, Rachel; Brown, Rebecca; Coke, Maira; Ducrot, Virginie; Egeler, Philipp; Holbech, Henrik; Hutchinson, Thomas H; Kinnberg, Karin L; Lagadic, Laurent; Le Page, Gareth; Macken, Ailbhe; Matthiessen, Peter; Ostermann, Sina; Schimera, Agnes; Schmitt, Claudia; Seeland-Fremer, Anne; Smith, Andy J; Weltje, Lennart; Oehlmann, Jörg

    2017-08-01

    Mollusks are known to be uniquely sensitive to a number of reproductive toxicants including some vertebrate endocrine disrupting chemicals. However, they have widely been ignored in environmental risk assessment procedures for chemicals. This study describes the validation of the Potamopyrgus antipodarum reproduction test within the OECD Conceptual Framework for Endocrine Disrupters Testing and Assessment. The number of embryos in the brood pouch and adult mortality serve as main endpoints. The experiments are conducted as static systems in beakers filled with artificial medium, which is aerated trough glass pipettes. The test chemical is dispersed into the medium, and adult snails are subsequently introduced into the beakers. After 28 days the reproductive success is determined by opening the brood pouch and embryo counting. This study presents the results of two validation studies of the reproduction test with eleven laboratories and the chemicals tributyltin (TBT) with nominal concentrations ranging from 10 to 1000 ng TBT-Sn/L and cadmium with concentrations from 1.56 to 25 μg/L. The test design could be implemented by all laboratories resulting in comparable effect concentrations for the endpoint number of embryos in the brood pouch. After TBT exposure mean EC 10 , EC 50 , NOEC and LOEC were 35.6, 127, 39.2 and 75.7 ng Sn/L, respectively. Mean effect concentrations in cadmium exposed snails were, respectively, 6.53, 14.2, 6.45 and 12.6 μg/L. The effect concentrations are in good accordance with already published data. Both validation studies show that the reproduction test with P. antipodarum is a well-suited tool to assess reproductive effects of chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. A Baseline Patient Model to Support Testing of Medical Cyber-Physical Systems.

    Science.gov (United States)

    Silva, Lenardo C; Perkusich, Mirko; Almeida, Hyggo O; Perkusich, Angelo; Lima, Mateus A M; Gorgônio, Kyller C

    2015-01-01

    Medical Cyber-Physical Systems (MCPS) are currently a trending topic of research. The main challenges are related to the integration and interoperability of connected medical devices, patient safety, physiologic closed-loop control, and the verification and validation of these systems. In this paper, we focus on patient safety and MCPS validation. We present a formal patient model to be used in health care systems validation without jeopardizing the patient's health. To determine the basic patient conditions, our model considers the four main vital signs: heart rate, respiratory rate, blood pressure and body temperature. To generate the vital signs we used regression models based on statistical analysis of a clinical database. Our solution should be used as a starting point for a behavioral patient model and adapted to specific clinical scenarios. We present the modeling process of the baseline patient model and show its evaluation. The conception process may be used to build different patient models. The results show the feasibility of the proposed model as an alternative to the immediate need for clinical trials to test these medical systems.

  14. Validation of risk-based performance indicators: Safety system function trends

    International Nuclear Information System (INIS)

    Boccio, J.L.; Vesely, W.E.; Azarm, M.A.; Carbonaro, J.F.; Usher, J.L.; Oden, N.

    1989-10-01

    This report describes and applies a process for validating a model for a risk-based performance indicator. The purpose of the risk-based indicator evaluated, Safety System Function Trend (SSFT), is to monitor the unavailability of selected safety systems. Interim validation of this indicator is based on three aspects: a theoretical basis, an empirical basis relying on statistical correlations, and case studies employing 25 plant years of historical data collected from five plants for a number of safety systems. Results using the SSFT model are encouraging. Application of the model through case studies dealing with the performance of important safety systems shows that statistically significant trends in, and levels of, system performance can be discerned which thereby can provide leading indications of degrading and/or improving performances. Methods for developing system performance tolerance bounds are discussed and applied to aid in the interpretation of the trends in this risk-based indicator. Some additional characteristics of the SSFT indicator, learned through the data-collection efforts and subsequent data analyses performed, are also discussed. The usefulness and practicality of other data sources for validation purposes are explored. Further validation of this indicator is noted. Also, additional research is underway in developing a more detailed estimator of system unavailability. 9 refs., 18 figs., 5 tabs

  15. Spacecraft Testing Programs: Adding Value to the Systems Engineering Process

    Science.gov (United States)

    Britton, Keith J.; Schaible, Dawn M.

    2011-01-01

    Testing has long been recognized as a critical component of spacecraft development activities - yet many major systems failures may have been prevented with more rigorous testing programs. The question is why is more testing not being conducted? Given unlimited resources, more testing would likely be included in a spacecraft development program. Striking the right balance between too much testing and not enough has been a long-term challenge for many industries. The objective of this paper is to discuss some of the barriers, enablers, and best practices for developing and sustaining a strong test program and testing team. This paper will also explore the testing decision factors used by managers; the varying attitudes toward testing; methods to develop strong test engineers; and the influence of behavior, culture and processes on testing programs. KEY WORDS: Risk, Integration and Test, Validation, Verification, Test Program Development

  16. Investigation of Spiral Bevel Gear Condition Indicator Validation Via AC-29-2C Using Damage Progression Tests

    Science.gov (United States)

    Dempsey, Paula J.

    2014-01-01

    This report documents the results of spiral bevel gear rig tests performed under a NASA Space Act Agreement with the Federal Aviation Administration (FAA) to support validation and demonstration of rotorcraft Health and Usage Monitoring Systems (HUMS) for maintenance credits via FAA Advisory Circular (AC) 29-2C, Section MG-15, Airworthiness Approval of Rotorcraft (HUMS) (Ref. 1). The overarching goal of this work was to determine a method to validate condition indicators in the lab that better represent their response to faults in the field. Using existing in-service helicopter HUMS flight data from faulted spiral bevel gears as a "Case Study," to better understand the differences between both systems, and the availability of the NASA Glenn Spiral Bevel Gear Fatigue Rig, a plan was put in place to design, fabricate and test comparable gear sets with comparable failure modes within the constraints of the test rig. The research objectives of the rig tests were to evaluate the capability of detecting gear surface pitting fatigue and other generated failure modes on spiral bevel gear teeth using gear condition indicators currently used in fielded HUMS. Nineteen final design gear sets were tested. Tables were generated for each test, summarizing the failure modes observed on the gear teeth for each test during each inspection interval and color coded based on damage mode per inspection photos. Gear condition indicators (CI) Figure of Merit 4 (FM4), Root Mean Square (RMS), +/- 1 Sideband Index (SI1) and +/- 3 Sideband Index (SI3) were plotted along with rig operational parameters. Statistical tables of the means and standard deviations were calculated within inspection intervals for each CI. As testing progressed, it became clear that certain condition indicators were more sensitive to a specific component and failure mode. These tests were clustered together for further analysis. Maintenance actions during testing were also documented. Correlation coefficients were

  17. Methodologies for verification and validation of expert systems as a function of component, criticality and life-cycle phase

    International Nuclear Information System (INIS)

    Miller, L.

    1992-01-01

    The review of verification and validation (V and V) methods presented here is based on results of the initial two tasks of a contract with the US Nuclear Regulatory Commission and the Electric Power Research Institute to Develop and Document Guidelines for Verifying and Validating Expert Systems. The first task was to review the applicability of conventional software techniques to expert systems; the second was to directly survey V and V practices associated with development of expert systems. Subsequent tasks will focus on selecting, synthesizing or developing V and V methods appropriate for the overall system, for specific expert systems components, and for different phases of the life-cycle. In addition, final guidelines will most likely be developed for each of three levels of expert systems: safety-related (systems whose functions directly relate to system safety, so-called safety-critical systems), important-to-safety (systems which support the critical safety functions), and non-safety (systems which are unrelated to safety functions). For the present purposes of categorizing and discussing various types of V and V methods, the authors simplify the life-cycle and consider only two aspects - systems validation phase. The authors identified a number of techniques for the first, combined, phase and two general classes of V and V techniques for the latter phase: static testing techniques, which do not involve execution of the system code, and dynamic testing techniques, which do. In the next two sections the author reviews first the applicability to expert systems of conventional V and V techniques and, second, the techniques expert system developers actually use. In the last section the authors make some general observations

  18. The development and validation of a test of science critical thinking for fifth graders.

    Science.gov (United States)

    Mapeala, Ruslan; Siew, Nyet Moi

    2015-01-01

    The paper described the development and validation of the Test of Science Critical Thinking (TSCT) to measure the three critical thinking skill constructs: comparing and contrasting, sequencing, and identifying cause and effect. The initial TSCT consisted of 55 multiple choice test items, each of which required participants to select a correct response and a correct choice of critical thinking used for their response. Data were obtained from a purposive sampling of 30 fifth graders in a pilot study carried out in a primary school in Sabah, Malaysia. Students underwent the sessions of teaching and learning activities for 9 weeks using the Thinking Maps-aided Problem-Based Learning Module before they answered the TSCT test. Analyses were conducted to check on difficulty index (p) and discrimination index (d), internal consistency reliability, content validity, and face validity. Analysis of the test-retest reliability data was conducted separately for a group of fifth graders with similar ability. Findings of the pilot study showed that out of initial 55 administered items, only 30 items with relatively good difficulty index (p) ranged from 0.40 to 0.60 and with good discrimination index (d) ranged within 0.20-1.00 were selected. The Kuder-Richardson reliability value was found to be appropriate and relatively high with 0.70, 0.73 and 0.92 for identifying cause and effect, sequencing, and comparing and contrasting respectively. The content validity index obtained from three expert judgments equalled or exceeded 0.95. In addition, test-retest reliability showed good, statistically significant correlations ([Formula: see text]). From the above results, the selected 30-item TSCT was found to have sufficient reliability and validity and would therefore represent a useful tool for measuring critical thinking ability among fifth graders in primary science.

  19. Verification and validation of computer based systems for PFBR

    International Nuclear Information System (INIS)

    Thirugnanamurthy, D.

    2017-01-01

    Verification and Validation (V and V) process is essential to build quality into system. Verification is the process of evaluating a system to determine whether the products of each development phase satisfies the requirements imposed by the previous phase. Validation is the process of evaluating a system at the end of the development process to ensure compliance with the functional, performance and interface requirements. This presentation elaborates the V and V process followed, documents submission requirements in each stage, V and V activities, check list used for reviews in each stage and reports

  20. Comparison of in-plant performance test data with analytic prediction of reactor safety system injection transient (U)

    International Nuclear Information System (INIS)

    Roy, B.N.; Neill, C.H. Jr.

    1993-01-01

    This paper compares the performance test data from injection transients for both of the subsystems of the Supplementary Safety System of the Savannah River Site production reactor with analytical predictions from an in-house thermal hydraulic computer code. The code was initially developed for design validation of the new Supplementary Safety System subsystem, but is shown to be equally capable of predicting the performance of the Supplementary Safety System existing subsystem even though the two subsystem transient injections have marked differences. The code itself was discussed and its validation using prototypic tests with simulated fluids was reported in an earlier paper (Roy and Nomm 1991)