WorldWideScience

Sample records for validation study electronic

  1. A magnetospheric specification model validation study: Geosynchronous electrons

    Science.gov (United States)

    Hilmer, R. V.; Ginet, G. P.

    2000-09-01

    The Rice University Magnetospheric Specification Model (MSM) is an operational space environment model of the inner and middle magnetosphere designed to specify charged particle fluxes up to 100keV. Validation test data taken between January 1996 and June 1998 consist of electron fluxes measured by a charge control system (CCS) on a defense satellite communications system (DSCS) spacecraft. The CCS includes both electrostatic analyzers to measure the particle environment and surface potential monitors to track differential charging between various materials and vehicle ground. While typical RMS error analysis methods provide a sense of the models overall abilities, they do not specifically address physical situations critical to operations, i.e., how well does the model specify when a high differential charging state is probable. In this validation study, differential charging states observed by DSCS are used to determine several threshold fluxes for the associated 20-50keV electrons and joint probability distributions are constructed to determine Hit, Miss, and False Alarm rates for the models. An MSM run covering the two and one-half year interval is performed using the minimum required input parameter set, consisting of only the magnetic activity index Kp, in order to statistically examine the model's seasonal and yearly performance. In addition, the relative merits of the input parameter, i.e., Kp, Dst, the equatorward boundary of diffuse aurora at midnight, cross-polar cap potential, solar wind density and velocity, and interplanetary magnetic field values, are evaluated as drivers of shorter model runs of 100 d each. In an effort to develop operational tools that can address spacecraft charging issues, we also identify temporal features in the model output that can be directly linked to input parameter variations and model boundary conditions. All model output is interpreted using the full three-dimensional, dipole tilt-dependent algorithms currently in

  2. Validation of asthma recording in electronic health records: a systematic review

    Directory of Open Access Journals (Sweden)

    Nissen F

    2017-12-01

    Full Text Available Francis Nissen,1 Jennifer K Quint,2 Samantha Wilkinson,1 Hana Mullerova,3 Liam Smeeth,1 Ian J Douglas1 1Department of Non-Communicable Disease Epidemiology, London School of Hygiene and Tropical Medicine, London, UK; 2National Heart and Lung Institute, Imperial College, London, UK; 3RWD & Epidemiology, GSK R&D, Uxbridge, UK Objective: To describe the methods used to validate asthma diagnoses in electronic health records and summarize the results of the validation studies. Background: Electronic health records are increasingly being used for research on asthma to inform health services and health policy. Validation of the recording of asthma diagnoses in electronic health records is essential to use these databases for credible epidemiological asthma research.Methods: We searched EMBASE and MEDLINE databases for studies that validated asthma diagnoses detected in electronic health records up to October 2016. Two reviewers independently assessed the full text against the predetermined inclusion criteria. Key data including author, year, data source, case definitions, reference standard, and validation statistics (including sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV] were summarized in two tables.Results: Thirteen studies met the inclusion criteria. Most studies demonstrated a high validity using at least one case definition (PPV >80%. Ten studies used a manual validation as the reference standard; each had at least one case definition with a PPV of at least 63%, up to 100%. We also found two studies using a second independent database to validate asthma diagnoses. The PPVs of the best performing case definitions ranged from 46% to 58%. We found one study which used a questionnaire as the reference standard to validate a database case definition; the PPV of the case definition algorithm in this study was 89%. Conclusion: Attaining high PPVs (>80% is possible using each of the discussed validation

  3. Validation of asthma recording in electronic health records: protocol for a systematic review.

    Science.gov (United States)

    Nissen, Francis; Quint, Jennifer K; Wilkinson, Samantha; Mullerova, Hana; Smeeth, Liam; Douglas, Ian J

    2017-05-29

    Asthma is a common, heterogeneous disease with significant morbidity and mortality worldwide. It can be difficult to define in epidemiological studies using electronic health records as the diagnosis is based on non-specific respiratory symptoms and spirometry, neither of which are routinely registered. Electronic health records can nonetheless be valuable to study the epidemiology, management, healthcare use and control of asthma. For health databases to be useful sources of information, asthma diagnoses should ideally be validated. The primary objectives are to provide an overview of the methods used to validate asthma diagnoses in electronic health records and summarise the results of the validation studies. EMBASE and MEDLINE will be systematically searched for appropriate search terms. The searches will cover all studies in these databases up to October 2016 with no start date and will yield studies that have validated algorithms or codes for the diagnosis of asthma in electronic health records. At least one test validation measure (sensitivity, specificity, positive predictive value, negative predictive value or other) is necessary for inclusion. In addition, we require the validated algorithms to be compared with an external golden standard, such as a manual review, a questionnaire or an independent second database. We will summarise key data including author, year of publication, country, time period, date, data source, population, case characteristics, clinical events, algorithms, gold standard and validation statistics in a uniform table. This study is a synthesis of previously published studies and, therefore, no ethical approval is required. The results will be submitted to a peer-reviewed journal for publication. Results from this systematic review can be used to study outcome research on asthma and can be used to identify case definitions for asthma. CRD42016041798. © Article author(s) (or their employer(s) unless otherwise stated in the text of the

  4. Development and validation of electronic surveillance tool for acute kidney injury: A retrospective analysis.

    Science.gov (United States)

    Ahmed, Adil; Vairavan, Srinivasan; Akhoundi, Abbasali; Wilson, Gregory; Chiofolo, Caitlyn; Chbat, Nicolas; Cartin-Ceba, Rodrigo; Li, Guangxi; Kashani, Kianoush

    2015-10-01

    Timely detection of acute kidney injury (AKI) facilitates prevention of its progress and potentially therapeutic interventions. The study objective is to develop and validate an electronic surveillance tool (AKI sniffer) to detect AKI in 2 independent retrospective cohorts of intensive care unit (ICU) patients. The primary aim is to compare the sensitivity, specificity, and positive and negative predictive values of AKI sniffer performance against a reference standard. This study is conducted in the ICUs of a tertiary care center. The derivation cohort study subjects were Olmsted County, MN, residents admitted to all Mayo Clinic ICUs from July 1, 2010, through December 31, 2010, and the validation cohort study subjects were all patients admitted to a Mayo Clinic, Rochester, campus medical/surgical ICU on January 12, 2010, through March 23, 2010. All included records were reviewed by 2 independent investigators who adjudicated AKI using the Acute Kidney Injury Network criteria; disagreements were resolved by a third reviewer. This constituted the reference standard. An electronic algorithm was developed; its precision and reliability were assessed in comparison with the reference standard in 2 separate cohorts, derivation and validation. Of 1466 screened patients, a total of 944 patients were included in the study: 482 for derivation and 462 for validation. Compared with the reference standard in the validation cohort, the sensitivity and specificity of the AKI sniffer were 88% and 96%, respectively. The Cohen κ (95% confidence interval) agreement between the electronic and the reference standard was 0.84 (0.78-0.89) and 0.85 (0.80-0.90) in the derivation and validation cohorts. Acute kidney injury can reliably and accurately be detected electronically in ICU patients. The presented method is applicable for both clinical (decision support) and research (enrollment for clinical trials) settings. Prospective validation is required. Copyright © 2015 Elsevier Inc. All

  5. Basic Conditions of Validity of Electronic Contracts in Iran and UNCITRAL Model Law

    Directory of Open Access Journals (Sweden)

    Abbas Karimi

    2017-02-01

    Full Text Available Diverse activities such as electronic exchange of goods and services, instant digital content delivery, electronic funds transfer, electronic stock exchange, electronic bill of lading, commercial projects, common engineering and design, sourcing, government purchase, direct marketing and post-sales services included in e-commerce field.  Due to the increasing spread of the electronic world in all aspects, electronic contracts, in turn, was of great importance and made significant contributions in business contracts. The present study aims to investigate the concept, fundamentals and history of electronic contracts referring to UNCITRAL Model Law on Electronic Commerce and Electronic Commerce Act (1996. The results indicate that in terms of the conclusion and obligations of the parties, contract in cyberspace in general is similar to the contract in the real world and in this respect, there is no major difference between these two contexts. Potential electronic contracts considered as written ones and Electronic signatures recognized as valid as the basis of the validity of the will in electronic trading.

  6. Electronic unit for fotovoltaic solar panelling validation

    International Nuclear Information System (INIS)

    Vazquez, J.; Valverde, J.; Garcia, J.M.

    1988-01-01

    A low cost and easy to use electronic system for photovoltaic solar panelling validation is described. It measures, with a certain periodicity, voltage and current given by the panel, determines the supplied power, and every so often, its maximum valves. The unit is fitted with a data storage system which allows data recording for later analysis. (Author)

  7. Using linked electronic data to validate algorithms for health outcomes in administrative databases.

    Science.gov (United States)

    Lee, Wan-Ju; Lee, Todd A; Pickard, Alan Simon; Shoaibi, Azadeh; Schumock, Glen T

    2015-08-01

    The validity of algorithms used to identify health outcomes in claims-based and administrative data is critical to the reliability of findings from observational studies. The traditional approach to algorithm validation, using medical charts, is expensive and time-consuming. An alternative method is to link the claims data to an external, electronic data source that contains information allowing confirmation of the event of interest. In this paper, we describe this external linkage validation method and delineate important considerations to assess the feasibility and appropriateness of validating health outcomes using this approach. This framework can help investigators decide whether to pursue an external linkage validation method for identifying health outcomes in administrative/claims data.

  8. Challenges in validating radiation sterilization with low energy electron irradiation

    International Nuclear Information System (INIS)

    Miller, A.; Helt-Hansen, J.

    2011-01-01

    Complete text of publication follows. Low energy electron irradiation (80-300 keV) is used increasingly for sterilization or decontamination in connection with isolators for aseptic filling lines in the pharmaceutical industry. It is not defined how validation for this process shall be carried out. A method can be derived from the medical device standard for radiation sterilization, ISO 11137, because the principles described in this standard can be applied to almost any industrial irradiation process. The validations elements are: Process definition, concerning specification of the dose required for the process and the maximum acceptable dose for the product. Installation qualification, concerning acceptance the irradiation facility. Operational qualification, concerning characterization of the facility. Performance qualification, concerning setting up the process. Process control, concerning routine monitoring. The limited penetration of the low energy electrons leads to problems with respect to executing these validation steps. This paper discusses these problems, and shows with examples how they can be solved.

  9. [Support of the nursing process through electronic nursing documentation systems (UEPD) – Initial validation of an instrument].

    Science.gov (United States)

    Hediger, Hannele; Müller-Staub, Maria; Petry, Heidi

    2016-01-01

    Electronic nursing documentation systems, with standardized nursing terminology, are IT-based systems for recording the nursing processes. These systems have the potential to improve the documentation of the nursing process and to support nurses in care delivery. This article describes the development and initial validation of an instrument (known by its German acronym UEPD) to measure the subjectively-perceived benefits of an electronic nursing documentation system in care delivery. The validity of the UEPD was examined by means of an evaluation study carried out in an acute care hospital (n = 94 nurses) in German-speaking Switzerland. Construct validity was analyzed by principal components analysis. Initial references of validity of the UEPD could be verified. The analysis showed a stable four factor model (FS = 0.89) scoring in 25 items. All factors loaded ≥ 0.50 and the scales demonstrated high internal consistency (Cronbach's α = 0.73 – 0.90). Principal component analysis revealed four dimensions of support: establishing nursing diagnosis and goals; recording a case history/an assessment and documenting the nursing process; implementation and evaluation as well as information exchange. Further testing with larger control samples and with different electronic documentation systems are needed. Another potential direction would be to employ the UEPD in a comparison of various electronic documentation systems.

  10. Electronic self-monitoring of mood using IT platforms in adult patients with bipolar disorder: A systematic review of the validity and evidence.

    Science.gov (United States)

    Faurholt-Jepsen, Maria; Munkholm, Klaus; Frost, Mads; Bardram, Jakob E; Kessing, Lars Vedel

    2016-01-15

    Various paper-based mood charting instruments are used in the monitoring of symptoms in bipolar disorder. During recent years an increasing number of electronic self-monitoring tools have been developed. The objectives of this systematic review were 1) to evaluate the validity of electronic self-monitoring tools as a method of evaluating mood compared to clinical rating scales for depression and mania and 2) to investigate the effect of electronic self-monitoring tools on clinically relevant outcomes in bipolar disorder. A systematic review of the scientific literature, reported according to the Preferred Reporting items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines was conducted. MEDLINE, Embase, PsycINFO and The Cochrane Library were searched and supplemented by hand search of reference lists. Databases were searched for 1) studies on electronic self-monitoring tools in patients with bipolar disorder reporting on validity of electronically self-reported mood ratings compared to clinical rating scales for depression and mania and 2) randomized controlled trials (RCT) evaluating electronic mood self-monitoring tools in patients with bipolar disorder. A total of 13 published articles were included. Seven articles were RCTs and six were longitudinal studies. Electronic self-monitoring of mood was considered valid compared to clinical rating scales for depression in six out of six studies, and in two out of seven studies compared to clinical rating scales for mania. The included RCTs primarily investigated the effect of heterogeneous electronically delivered interventions; none of the RCTs investigated the sole effect of electronic mood self-monitoring tools. Methodological issues with risk of bias at different levels limited the evidence in the majority of studies. Electronic self-monitoring of mood in depression appears to be a valid measure of mood in contrast to self-monitoring of mood in mania. There are yet few studies on the effect of electronic

  11. Validation of multisource electronic health record data: an application to blood transfusion data.

    Science.gov (United States)

    Hoeven, Loan R van; Bruijne, Martine C de; Kemper, Peter F; Koopman, Maria M W; Rondeel, Jan M M; Leyte, Anja; Koffijberg, Hendrik; Janssen, Mart P; Roes, Kit C B

    2017-07-14

    Although data from electronic health records (EHR) are often used for research purposes, systematic validation of these data prior to their use is not standard practice. Existing validation frameworks discuss validity concepts without translating these into practical implementation steps or addressing the potential influence of linking multiple sources. Therefore we developed a practical approach for validating routinely collected data from multiple sources and to apply it to a blood transfusion data warehouse to evaluate the usability in practice. The approach consists of identifying existing validation frameworks for EHR data or linked data, selecting validity concepts from these frameworks and establishing quantifiable validity outcomes for each concept. The approach distinguishes external validation concepts (e.g. concordance with external reports, previous literature and expert feedback) and internal consistency concepts which use expected associations within the dataset itself (e.g. completeness, uniformity and plausibility). In an example case, the selected concepts were applied to a transfusion dataset and specified in more detail. Application of the approach to a transfusion dataset resulted in a structured overview of data validity aspects. This allowed improvement of these aspects through further processing of the data and in some cases adjustment of the data extraction. For example, the proportion of transfused products that could not be linked to the corresponding issued products initially was 2.2% but could be improved by adjusting data extraction criteria to 0.17%. This stepwise approach for validating linked multisource data provides a basis for evaluating data quality and enhancing interpretation. When the process of data validation is adopted more broadly, this contributes to increased transparency and greater reliability of research based on routinely collected electronic health records.

  12. Validation Test of Geant4 Simulation of Electron Backscattering

    CERN Document Server

    Kim, Sung Hun; Basaglia, Tullio; Han, Min Cheol; Hoff, Gabriela; Kim, Chan Hyeong; Saracco, Paolo

    2015-01-01

    Backscattering is a sensitive probe of the accuracy of electron scattering algorithms implemented in Monte Carlo codes. The capability of the Geant4 toolkit to describe realistically the fraction of electrons backscattered from a target volume is extensively and quantitatively evaluated in comparison with experimental data retrieved from the literature. The validation test covers the energy range between approximately 100 eV and 20 MeV, and concerns a wide set of target elements. Multiple and single electron scattering models implemented in Geant4, as well as preassembled selections of physics models distributed within Geant4, are analyzed with statistical methods. The evaluations concern Geant4 versions from 9.1 to 10.1. Significant evolutions are observed over the range of Geant4 versions, not always in the direction of better compatibility with experiment. Goodness-of-fit tests complemented by categorical analysis tests identify a configuration based on Geant4 Urban multiple scattering model in Geant4 vers...

  13. Study and impact of fast electrons diagnosed by electron cyclotron radiation on Tore-Supra tokamak

    International Nuclear Information System (INIS)

    Gomez, P.

    1999-12-01

    This thesis aims at characterizing the dynamics of fast electrons generated by the Landau absorption of the hybrid wave and studying their effects on electron cyclotron radiation. The different processes involved in the propagation and resonant absorption of the hybrid wave in plasmas are described. A method such as ray-tracing allows the characterization of the dynamics of heating but this method relies on the hypothesis of geometrical optics. Whenever absorption rate is low as it is in Tore-Supra, the hybrid wave undergoes a series of successive reflections on the edge of the plasma before being completely absorbed. These reflections generate an electromagnetic chaos in which geometrical optics hypothesis are no longer valid. A statistical treatment of the Fokker-Planck equation allows the calculation of the mean distribution function of electrons in the plasma submitted to hybrid wave. The electron cyclotron radiation is then deduced and by assuming that plasma behaves like a black body, a theoretical radiative temperature is calculated. The confrontation of this theoretical temperature profile with experimental values allows the validation of this modeling and the estimation of the effects of fast electrons on temperature measurements. (A.C.)

  14. Validation of a Delirium Risk Assessment Using Electronic Medical Record Information.

    Science.gov (United States)

    Rudolph, James L; Doherty, Kelly; Kelly, Brittany; Driver, Jane A; Archambault, Elizabeth

    2016-03-01

    Identifying patients at risk for delirium allows prompt application of prevention, diagnostic, and treatment strategies; but is rarely done. Once delirium develops, patients are more likely to need posthospitalization skilled care. This study developed an a priori electronic prediction rule using independent risk factors identified in a National Center of Clinical Excellence meta-analysis and validated the ability to predict delirium in 2 cohorts. Retrospective analysis followed by prospective validation. Tertiary VA Hospital in New England. A total of 27,625 medical records of hospitalized patients and 246 prospectively enrolled patients admitted to the hospital. The electronic delirium risk prediction rule was created using data obtained from the patient electronic medical record (EMR). The primary outcome, delirium, was identified 2 ways: (1) from the EMR (retrospective cohort) and (2) clinical assessment on enrollment and daily thereafter (prospective participants). We assessed discrimination of the delirium prediction rule with the C-statistic. Secondary outcomes were length of stay and discharge to rehabilitation. Retrospectively, delirium was identified in 8% of medical records (n = 2343); prospectively, delirium during hospitalization was present in 26% of participants (n = 64). In the retrospective cohort, medical record delirium was identified in 2%, 3%, 11%, and 38% of the low, intermediate, high, and very high-risk groups, respectively (C-statistic = 0.81; 95% confidence interval 0.80-0.82). Prospectively, the electronic prediction rule identified delirium in 15%, 18%, 31%, and 55% of these groups (C-statistic = 0.69; 95% confidence interval 0.61-0.77). Compared with low-risk patients, those at high- or very high delirium risk had increased length of stay (5.7 ± 5.6 vs 3.7 ± 2.7 days; P = .001) and higher rates of discharge to rehabilitation (8.9% vs 20.8%; P = .02). Automatic calculation of delirium risk using an EMR algorithm identifies patients at

  15. Dual-Material Electron Beam Selective Melting: Hardware Development and Validation Studies

    Directory of Open Access Journals (Sweden)

    Chao Guo

    2015-03-01

    Full Text Available Electron beam selective melting (EBSM is an additive manufacturing technique that directly fabricates three-dimensional parts in a layerwise fashion by using an electron beam to scan and melt metal powder. In recent years, EBSM has been successfully used in the additive manufacturing of a variety of materials. Previous research focused on the EBSM process of a single material. In this study, a novel EBSM process capable of building a gradient structure with dual metal materials was developed, and a powder-supplying method based on vibration was put forward. Two different powders can be supplied individually and then mixed. Two materials were used in this study: Ti6Al4V powder and Ti47Al2Cr2Nb powder. Ti6Al4V has excellent strength and plasticity at room temperature, while Ti47Al2Cr2Nb has excellent performance at high temperature, but is very brittle. A Ti6Al4V/Ti47Al2Cr2Nb gradient material was successfully fabricated by the developed system. The microstructures and chemical compositions were characterized by optical microscopy, scanning microscopy, and electron microprobe analysis. Results showed that the interface thickness was about 300 μm. The interface was free of cracks, and the chemical compositions exhibited a staircase-like change within the interface.

  16. Electronic and optical properties of Fe, Pd, and Ti studied by reflection electron energy loss spectroscopy

    International Nuclear Information System (INIS)

    Tahir, Dahlang; Kraaer, Jens; Tougaard, Sven

    2014-01-01

    We have studied the electronic and optical properties of Fe, Pd, and Ti by reflection electron energy-loss spectroscopy (REELS). REELS spectra recorded for primary energies in the range from 300 eV to 10 keV were corrected for multiple inelastically scattered electrons to determine the effective inelastic-scattering cross section. The dielectric functions and optical properties were determined by comparing the experimental inelastic-electron scattering cross section with a simulated cross section calculated within the semi-classical dielectric response model in which the only input is Im(−1/ε) by using the QUEELS-ε(k,ω)-REELS software package. The complex dielectric functions ε(k,ω), in the 0–100 eV energy range, for Fe, Pd, and Ti were determined from the derived Im(−1/ε) by Kramers-Kronig transformation and then the refractive index n and extinction coefficient k. The validity of the applied model was previously tested and found to give consistent results when applied to REELS spectra at energies between 300 and 1000 eV taken at widely different experimental geometries. In the present paper, we provide, for the first time, a further test on its validity and find that the model also gives consistent results when applied to REELS spectra in the full range of primary electron energies from 300 eV to 10000 eV. This gives confidence in the validity of the applied method.

  17. Non-local electron transport validation using 2D DRACO simulations

    Science.gov (United States)

    Cao, Duc; Chenhall, Jeff; Moll, Eli; Prochaska, Alex; Moses, Gregory; Delettrez, Jacques; Collins, Tim

    2012-10-01

    Comparison of 2D DRACO simulations, using a modified versionfootnotetextprivate communications with M. Marinak and G. Zimmerman, LLNL. of the Schurtz, Nicolai and Busquet (SNB) algorithmfootnotetextSchurtz, Nicolai and Busquet, ``A nonlocal electron conduction model for multidimensional radiation hydrodynamics codes,'' Phys. Plasmas 7, 4238(2000). for non-local electron transport, with direct drive shock timing experimentsfootnotetextT. Boehly, et. al., ``Multiple spherically converging shock waves in liquid deuterium,'' Phys. Plasmas 18, 092706(2011). and with the Goncharov non-local modelfootnotetextV. Goncharov, et. al., ``Early stage of implosion in inertial confinement fusion: Shock timing and perturbation evolution,'' Phys. Plasmas 13, 012702(2006). in 1D LILAC will be presented. Addition of an improved SNB non-local electron transport algorithm in DRACO allows direct drive simulations with no need for an electron conduction flux limiter. Validation with shock timing experiments that mimic the laser pulse profile of direct drive ignition targets gives a higher confidence level in the predictive capability of the DRACO code. This research was supported by the University of Rochester Laboratory for Laser Energetics.

  18. Materials of the Regional Training Course on Validation and Process Control for Electron Beam Radiation Processing

    International Nuclear Information System (INIS)

    Kaluska, I.; Gluszewski, W.

    2007-01-01

    Irradiation with electron beams is used in the polymer industry, food, pharmaceutical and medical device industries for sterilization of surfaces. About 20 lectures presented during the Course were devoted to all aspects of control and validation of low energy electron beam processes. They should help the product manufacturers better understand the application of the ANSI/AAMI/ISO 11137 norm, which defines the requirements and standard practices for validation of the irradiation process and the process controls required during routine processing

  19. Derivation and validation of the automated search algorithms to identify cognitive impairment and dementia in electronic health records.

    Science.gov (United States)

    Amra, Sakusic; O'Horo, John C; Singh, Tarun D; Wilson, Gregory A; Kashyap, Rahul; Petersen, Ronald; Roberts, Rosebud O; Fryer, John D; Rabinstein, Alejandro A; Gajic, Ognjen

    2017-02-01

    Long-term cognitive impairment is a common and important problem in survivors of critical illness. We developed electronic search algorithms to identify cognitive impairment and dementia from the electronic medical records (EMRs) that provide opportunity for big data analysis. Eligible patients met 2 criteria. First, they had a formal cognitive evaluation by The Mayo Clinic Study of Aging. Second, they were hospitalized in intensive care unit at our institution between 2006 and 2014. The "criterion standard" for diagnosis was formal cognitive evaluation supplemented by input from an expert neurologist. Using all available EMR data, we developed and improved our algorithms in the derivation cohort and validated them in the independent validation cohort. Of 993 participants who underwent formal cognitive testing and were hospitalized in intensive care unit, we selected 151 participants at random to form the derivation and validation cohorts. The automated electronic search algorithm for cognitive impairment was 94.3% sensitive and 93.0% specific. The search algorithms for dementia achieved respective sensitivity and specificity of 97% and 99%. EMR search algorithms significantly outperformed International Classification of Diseases codes. Automated EMR data extractions for cognitive impairment and dementia are reliable and accurate and can serve as acceptable and efficient alternatives to time-consuming manual data review. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  1. Validation of fragility fractures in primary care electronic medical records: A population-based study.

    Science.gov (United States)

    Martinez-Laguna, Daniel; Soria-Castro, Alberto; Carbonell-Abella, Cristina; Orozco-López, Pilar; Estrada-Laza, Pilar; Nogues, Xavier; Díez-Perez, Adolfo; Prieto-Alhambra, Daniel

    2017-11-28

    Electronic medical records databases use pre-specified lists of diagnostic codes to identify fractures. These codes, however, are not specific enough to disentangle traumatic from fragility-related fractures. We report on the proportion of fragility fractures identified in a random sample of coded fractures in SIDIAP. Patients≥50 years old with any fracture recorded in 2012 (as per pre-specified ICD-10 codes) and alive at the time of recruitment were eligible for this retrospective observational study in 6 primary care centres contributing to the SIDIAP database (www.sidiap.org). Those with previous fracture/s, non-responders, and those with dementia or a serious psychiatric disease were excluded. Data on fracture type (traumatic vs fragility), skeletal site, and basic patient characteristics were collected. Of 491/616 (79.7%) patients with a registered fracture in 2012 who were contacted, 331 (349 fractures) were included. The most common fractures were forearm (82), ribs (38), and humerus (32), and 225/349 (64.5%) were fragility fractures, with higher proportions for classic osteoporotic sites: hip, 91.7%; spine, 87.7%; and major fractures, 80.5%. This proportion was higher in women, the elderly, and patients with a previously coded diagnosis of osteoporosis. More than 4 in 5 major fractures recorded in SIDIAP are due to fragility (non-traumatic), with higher proportions for hip (92%) and vertebral (88%) fracture, and a lower proportion for fractures other than major ones. Our data support the validity of SIDIAP for the study of the epidemiology of osteoporotic fractures. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  2. Validating the Technology Acceptance Model in the Context of the Laboratory Information System-Electronic Health Record Interface System

    Science.gov (United States)

    Aquino, Cesar A.

    2014-01-01

    This study represents a research validating the efficacy of Davis' Technology Acceptance Model (TAM) by pairing it with the Organizational Change Readiness Theory (OCRT) to develop another extension to the TAM, using the medical Laboratory Information Systems (LIS)--Electronic Health Records (EHR) interface as the medium. The TAM posits that it is…

  3. Validity of the independent-processes approximation for resonance structures in electron-ion scattering cross sections

    International Nuclear Information System (INIS)

    Badnell, N.R.; Pindzola, M.S.; Griffin, D.C.

    1991-01-01

    The total inelastic cross section for electron-ion scattering may be found in the independent-processes approximation by adding the resonant cross section to the nonresonant background cross section. We study the validity of this approximation for electron excitation of multiply charged ions. The resonant-excitation cross section is calculated independently using distorted waves for various Li-like and Na-like ions using (N+1)-electron atomic-structure methods previously developed for the calculation of dielectronic-recombination cross sections. To check the effects of interference between the two scattering processes, we also carry out detailed close-coupling calculations for the same atomic ions using the R-matrix method. For low ionization stages, interference effects manifest themselves sometimes as strong window features in the close-coupling cross section, which are not present in the independent-processes cross section. For higher ionization stages, however, the resonance features found in the independent-processes approximation are found to be in good agreement with the close-coupling results

  4. Content validity and electronic PRO (ePRO) usability of the Lung Cancer Symptom Scale-Mesothelioma (LCSS-Meso) in mesothelioma patients.

    Science.gov (United States)

    Gelhorn, Heather L; Skalicky, Anne M; Balantac, Zaneta; Eremenco, Sonya; Cimms, Tricia; Halling, Katarina; Hollen, Patricia J; Gralla, Richard J; Mahoney, Martin C; Sexton, Chris

    2018-02-01

    Obtaining qualitative data directly from the patient perspective enhances the content validity of patient-reported outcome (PRO) instruments. The objective of this qualitative study was to evaluate the content validity of the Lung Cancer Symptom Scale for Mesothelioma (LCSS-Meso) and its usability on an electronic device. A cross-sectional methodological study, using a qualitative approach, was conducted among patients recruited from four clinical sites. The primary target population included patients with pleural mesothelioma; data were also collected from patients with peritoneal mesothelioma on an exploratory basis. Semi-structured interviews were conducted consisting of concept elicitation, cognitive interviewing, and evaluation of electronic patient-reported outcome (ePRO) usability. Participants (n = 21) were interviewed in person (n = 9) or by telephone (n = 12); 71% were male with a mean age of 69 years (SD = 14). The most common signs and symptoms experienced by participants with pleural mesothelioma (n = 18) were shortness of breath, fluid build-up, pain, fatigue, coughing, and appetite loss. The most commonly described symptoms for those with peritoneal mesothelioma (n = 4) were bloating, changes in appetite, fatigue, fluid build-up, shortness of breath, and pain. Participants with pleural mesothelioma commonly described symptoms assessed by the LCSS-Meso in language consistent with the questionnaire and a majority understood and easily completed each of the items. The ePRO version was easy to use, and there was no evidence that the electronic formatting changed the way participants responded to the questions. Results support the content validity of the LCSS-Meso and the usability of the electronic format for use in assessing symptoms among patients with pleural mesothelioma.

  5. Valid Probabilistic Predictions for Ginseng with Venn Machines Using Electronic Nose

    Directory of Open Access Journals (Sweden)

    You Wang

    2016-07-01

    Full Text Available In the application of electronic noses (E-noses, probabilistic prediction is a good way to estimate how confident we are about our prediction. In this work, a homemade E-nose system embedded with 16 metal-oxide semi-conductive gas sensors was used to discriminate nine kinds of ginsengs of different species or production places. A flexible machine learning framework, Venn machine (VM was introduced to make probabilistic predictions for each prediction. Three Venn predictors were developed based on three classical probabilistic prediction methods (Platt’s method, Softmax regression and Naive Bayes. Three Venn predictors and three classical probabilistic prediction methods were compared in aspect of classification rate and especially the validity of estimated probability. A best classification rate of 88.57% was achieved with Platt’s method in offline mode, and the classification rate of VM-SVM (Venn machine based on Support Vector Machine was 86.35%, just 2.22% lower. The validity of Venn predictors performed better than that of corresponding classical probabilistic prediction methods. The validity of VM-SVM was superior to the other methods. The results demonstrated that Venn machine is a flexible tool to make precise and valid probabilistic prediction in the application of E-nose, and VM-SVM achieved the best performance for the probabilistic prediction of ginseng samples.

  6. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    Science.gov (United States)

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; Ppreferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  7. Validation of an electronic surveillance system for acute lung injury.

    Science.gov (United States)

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D; Gajic, Ognjen

    2009-06-01

    Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Using a near-real time copy of the electronic medical records, we developed and validated a custom ALI electronic alert (ALI "sniffer") based on the European-American Consensus Conference Definition and compared its performance against provider-derived documentation. A total of 3,795 consecutive critically ill patients admitted to nine multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution were included. ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs. 8.0 ml/kg predicted body weight, P sniffer" demonstrated excellent sensitivity of 96% (95% CI 94-98) and moderate specificity of 89% (95% CI 88-90) with a positive predictive value ranging from 24% (95% CI 13-40) in the heart-lung transplant ICU to 64% (95% CI 55-71) in the medical ICU. The computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research.

  8. From patient care to research: a validation study examining the factors contributing to data quality in a primary care electronic medical record database.

    Science.gov (United States)

    Coleman, Nathan; Halas, Gayle; Peeler, William; Casaclang, Natalie; Williamson, Tyler; Katz, Alan

    2015-02-05

    Electronic Medical Records (EMRs) are increasingly used in the provision of primary care and have been compiled into databases which can be utilized for surveillance, research and informing practice. The primary purpose of these records is for the provision of individual patient care; validation and examination of underlying limitations is crucial for use for research and data quality improvement. This study examines and describes the validity of chronic disease case definition algorithms and factors affecting data quality in a primary care EMR database. A retrospective chart audit of an age stratified random sample was used to validate and examine diagnostic algorithms applied to EMR data from the Manitoba Primary Care Research Network (MaPCReN), part of the Canadian Primary Care Sentinel Surveillance Network (CPCSSN). The presence of diabetes, hypertension, depression, osteoarthritis and chronic obstructive pulmonary disease (COPD) was determined by review of the medical record and compared to algorithm identified cases to identify discrepancies and describe the underlying contributing factors. The algorithm for diabetes had high sensitivity, specificity and positive predictive value (PPV) with all scores being over 90%. Specificities of the algorithms were greater than 90% for all conditions except for hypertension at 79.2%. The largest deficits in algorithm performance included poor PPV for COPD at 36.7% and limited sensitivity for COPD, depression and osteoarthritis at 72.0%, 73.3% and 63.2% respectively. Main sources of discrepancy included missing coding, alternative coding, inappropriate diagnosis detection based on medications used for alternate indications, inappropriate exclusion due to comorbidity and loss of data. Comparison to medical chart review shows that at MaPCReN the CPCSSN case finding algorithms are valid with a few limitations. This study provides the basis for the validated data to be utilized for research and informs users of its

  9. Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients

    Directory of Open Access Journals (Sweden)

    Steiger Jürg

    2008-02-01

    Full Text Available Abstract Background Electronic monitoring (EM is used increasingly to measure medication non-adherence. Unbiased EM assessment requires fulfillment of assumptions. The purpose of this study was to determine assumptions needed for internal and external validity of EM measurement. To test internal validity, we examined if (1 EM equipment functioned correctly, (2 if all EM bottle openings corresponded to actual drug intake, and (3 if EM did not influence a patient's normal adherence behavior. To assess external validity, we examined if there were indications that using EM affected the sample representativeness. Methods We used data from the Supporting Medication Adherence in Renal Transplantation (SMART study, which included 250 adult renal transplant patients whose adherence to immunosuppressive drugs was measured during 3 months with the Medication Event Monitoring System (MEMS. Internal validity was determined by assessing the prevalence of nonfunctioning EM systems, the prevalence of patient-reported discrepancies between cap openings and actual intakes (using contemporaneous notes and interview at the end of the study, and by exploring whether adherence was initially uncharacteristically high and decreased over time (an indication of a possible EM intervention effect. Sample representativeness was examined by screening for differences between participants and non-participants or drop outs on non-adherence. Results Our analysis revealed that some assumptions were not fulfilled: 1 one cap malfunctioned (0.4%, 2 self-reported mismatches between bottle openings and actual drug intake occurred in 62% of the patients (n = 155, and 3 adherence decreased over the first 5 weeks of the monitoring, indicating that EM had a waning intervention effect. Conclusion The validity assumptions presented in this article should be checked in future studies using EM as a measure of medication non-adherence.

  10. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ming, W.Q.; Chen, J.H., E-mail: jhchen123@hnu.edu.cn

    2013-11-15

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations.

  11. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    International Nuclear Information System (INIS)

    Ming, W.Q.; Chen, J.H.

    2013-01-01

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations

  12. Online crowdsourcing for efficient rating of speech: a validation study.

    Science.gov (United States)

    McAllister Byun, Tara; Halpin, Peter F; Szeredi, Daniel

    2015-01-01

    Blinded listener ratings are essential for valid assessment of interventions for speech disorders, but collecting these ratings can be time-intensive and costly. This study evaluated the validity of speech ratings obtained through online crowdsourcing, a potentially more efficient approach. 100 words from children with /r/ misarticulation were electronically presented for binary rating by 35 phonetically trained listeners and 205 naïve listeners recruited through the Amazon Mechanical Turk (AMT) crowdsourcing platform. Bootstrapping was used to compare different-sized samples of AMT listeners against a "gold standard" (mode across all trained listeners) and an "industry standard" (mode across bootstrapped samples of three trained listeners). There was strong overall agreement between trained and AMT listeners. The "industry standard" level of performance was matched by bootstrapped samples with n = 9 AMT listeners. These results support the hypothesis that valid ratings of speech data can be obtained in an efficient manner through AMT. Researchers in communication disorders could benefit from increased awareness of this method. Readers will be able to (a) discuss advantages and disadvantages of data collection through the crowdsourcing platform Amazon Mechanical Turk (AMT), (b) describe the results of a validity study comparing samples of AMT listeners versus phonetically trained listeners in a speech-rating task. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Validating an electronic health literacy scale in an older hispanic population.

    Science.gov (United States)

    Aponte, Judith; Nokes, Kathleen M

    2017-09-01

    To examine the validity of the Spanish version of an instrument used to measure electronic health literacy (eHEALS) with an older Hispanic population from a number of Spanish-language countries living in New York City in the United States (US). Although the Internet is available globally, complex skills are needed to use this source of valuable health-related information effectively. Electronic health literacy is a multifactorial concept that includes health literacy but also requires technology skills. Cross-sectional. Recruitment occurred at a Senior Organization located in a largely Hispanic neighbourhood in New York City (N = 100). Participants completed eHEALS and selected items from the Health Information National Trends Survey (HINTS) which assesses how adults use different communication channels, including the Internet, to obtain vital health information. Data from the US HINTS sample (N = 162) were matched to the Senior Organization sample on age range and Hispanic ethnicity. The average Senior Organization participant was 68 years old, female, born in one of six different Spanish-language countries, and completed high school while the average HINTS participant was 67 years old, female and had high school or less education. Although there was no relationship with the two HINTS subscales and electronic health literacy, there were significant relationships between electronic health literacy and health status and confidence in self-care. Inadequate electronic health literacy is a barrier to positive health outcomes. The Spanish version of eHEALS could be used as a screening instrument to identify gaps and tailored interventions could be developed to increase consumer confidence in using the Internet for reliable health-related information. Knowledge in self-management is related to positive health outcomes; all persons irrespective of their electronic health literacy should be able to use all sources of health information to enhance their self-care.

  14. Validation of honey-bee smelling profile by using a commercial electronic nose

    Directory of Open Access Journals (Sweden)

    Ana R. Correa

    2017-09-01

    Full Text Available Honey is a natural sweetener and its quality labels are associated to its botanical or geographical origin, which is being established by palynological and sensorial analysis. The use of fast and non-invasive techniques such as an electronic nose can become an alternative for honey classification. In this study, the operational parameters of a commercial electronic nose were validated to determine the honey odor profile. A central composite design with five factors, three levels and 28 assays was used, varying sample amounts (1, 2 and 3 g, incubation temperature (30, 40 and 50 °C, incubation time 30 min, gas flow (50, 150 and 250 mL/min and injection time (100, 200 and 300 s. The commercial nose had ten sensors. Repeatability was evaluated with a coefficient of variation of 10 %. The response surface methodology was used and the optimal operating conditions were: 3 g of sample, incubation at 50 °C for 17 min, gas flow of 100 mL/min and sampling time of 150 s. Finally, these parameters were used to analyze 19 samples of honey, which were classified according to their odor profiles, showing that it can be a useful tool to classify honey.

  15. Semantic validation of standard-based electronic health record documents with W3C XML schema.

    Science.gov (United States)

    Rinner, C; Janzek-Hawlat, S; Sibinovic, S; Duftschmid, G

    2010-01-01

    The goal of this article is to examine whether W3C XML Schema provides a practicable solution for the semantic validation of standard-based electronic health record (EHR) documents. With semantic validation we mean that the EHR documents are checked for conformance with the underlying archetypes and reference model. We describe an approach that allows XML Schemas to be derived from archetypes based on a specific naming convention. The archetype constraints are augmented with additional components of the reference model within the XML Schema representation. A copy of the EHR document that is transformed according to the before-mentioned naming convention is used for the actual validation against the XML Schema. We tested our approach by semantically validating EHR documents conformant to three different ISO/EN 13606 archetypes respective to three sections of the CDA implementation guide "Continuity of Care Document (CCD)" and an implementation guide for diabetes therapy data. We further developed a tool to automate the different steps of our semantic validation approach. For two particular kinds of archetype prescriptions, individual transformations are required for the corresponding EHR documents. Otherwise, a fully generic validation is possible. In general, we consider W3C XML Schema as a practicable solution for the semantic validation of standard-based EHR documents.

  16. Electronic self-monitoring of mood using IT platforms in adult patients with bipolar disorder: A systematic review of the validity and evidence

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Munkholm, Klaus; Frost, Mads

    2016-01-01

    -monitoring is limited by methodological issues and by a lack of RCTs. Although the idea of electronic self-monitoring of mood seems appealing, studies using rigorous methodology investigating the beneficial as well as possible harmful effects of electronic self-monitoring are needed.......Background: Various paper-based mood charting instruments are used in the monitoring of symptoms in bipolar disorder. During recent years an increasing number of electronic self-monitoring tools have been developed. The objectives of this systematic review were 1) to evaluate the validity...... of electronic self-monitoring tools as a method of evaluating mood compared to clinical rating scales for depression and mania and 2) to investigate the effect of electronic self-monitoring tools on clinically relevant outcomes in bipolar disorder. Methods: A systematic review of the scientific literature...

  17. Validation of Using Fitness Center Attendance Electronic Records to Assess the Frequency of Moderate/Vigorous Leisure-Time Physical Activity among Adults

    Science.gov (United States)

    Amireault, Steve; Godin, Gaston

    2014-01-01

    The purpose of this study was to provide three construct validity evidence for using fitness center attendance electronic records to objectively assess the frequency of leisure-time physical activity among adults. One hundred members of a fitness center (45 women and 55 men; aged 18 to 64 years) completed a self-report leisure-time physical…

  18. A GLOBAL TWO-TEMPERATURE CORONA AND INNER HELIOSPHERE MODEL: A COMPREHENSIVE VALIDATION STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Jin, M.; Manchester, W. B.; Van der Holst, B.; Gruesbeck, J. R.; Frazin, R. A.; Landi, E.; Toth, G.; Gombosi, T. I. [Atmospheric Oceanic and Space Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Vasquez, A. M. [Instituto de Astronomia y Fisica del Espacio (CONICET-UBA) and FCEN (UBA), CC 67, Suc 28, Ciudad de Buenos Aires (Argentina); Lamy, P. L.; Llebaria, A.; Fedorov, A., E-mail: jinmeng@umich.edu [Laboratoire d' Astrophysique de Marseille, Universite de Provence, Marseille (France)

    2012-01-20

    The recent solar minimum with very low activity provides us a unique opportunity for validating solar wind models. During CR2077 (2008 November 20 through December 17), the number of sunspots was near the absolute minimum of solar cycle 23. For this solar rotation, we perform a multi-spacecraft validation study for the recently developed three-dimensional, two-temperature, Alfven-wave-driven global solar wind model (a component within the Space Weather Modeling Framework). By using in situ observations from the Solar Terrestrial Relations Observatory (STEREO) A and B, Advanced Composition Explorer (ACE), and Venus Express, we compare the observed proton state (density, temperature, and velocity) and magnetic field of the heliosphere with that predicted by the model. Near the Sun, we validate the numerical model with the electron density obtained from the solar rotational tomography of Solar and Heliospheric Observatory/Large Angle and Spectrometric Coronagraph C2 data in the range of 2.4 to 6 solar radii. Electron temperature and density are determined from differential emission measure tomography (DEMT) of STEREO A and B Extreme Ultraviolet Imager data in the range of 1.035 to 1.225 solar radii. The electron density and temperature derived from the Hinode/Extreme Ultraviolet Imaging Spectrometer data are also used to compare with the DEMT as well as the model output. Moreover, for the first time, we compare ionic charge states of carbon, oxygen, silicon, and iron observed in situ with the ACE/Solar Wind Ion Composition Spectrometer with those predicted by our model. The validation results suggest that most of the model outputs for CR2077 can fit the observations very well. Based on this encouraging result, we therefore expect great improvement for the future modeling of coronal mass ejections (CMEs) and CME-driven shocks.

  19. Electron Temperature Fluctuation Measurements and Transport Model Validation at Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    White, Anne [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2017-06-22

    The tokamak is a type of toroidal device used to confine a fusion plasma using large magnetic fields. Tokamaks and stellarators the leading devices for confining plasmas for fusion, and the capability to predict performance in these magnetically confined plasmas is essential for developing a sustainable fusion energy source. The magnetic configuration of tokamaks and stellarators does not exist in Nature, yet, the fundamental processes governing transport in fusion plasmas are universal – turbulence and instabilities, driven by inhomogeneity and asymmetry in the plasma, conspire to transport heat and particles across magnetic field lines and can play critical roles in impurity confinement and generation of intrinsic rotation. Turbulence exists in all plasmas, and in neutral fluids as well. The study of turbulence is essential to developing a fundamental understanding of the nature of the fourth state of matter, plasmas. Experimental studies of turbulence in tokamaks date back to early scattering observations from the late 1970s. Since that time, great advances in turbulence diagnostics have been made, all of which have significantly enhanced our knowledge and understanding of turbulence in tokamaks. Through comparisons with advanced gyrokinetic theory and turbulent-transport models a great deal of evidence exists to implicate turbulent-driven transport as an important mechanism determining transport in all channels: heat, particle and momentum However, prediction and control of turbulent-driven transport remains elusive. Key to development of predictive transport models for magnetically confined fusion plasmas is validation of the nonlinear gyrokinetic transport model, which describes transport due to turbulence. Validation of gyrokinetic codes must include detailed and quantitative comparisons with measured turbulence characteristics, in addition to comparisons with inferred transport levels and equilibrium profiles. For this reason, advanced plasma diagnostics

  20. ClinicalCodes: an online clinical codes repository to improve the validity and reproducibility of research using electronic medical records.

    Science.gov (United States)

    Springate, David A; Kontopantelis, Evangelos; Ashcroft, Darren M; Olier, Ivan; Parisi, Rosa; Chamapiwa, Edmore; Reeves, David

    2014-01-01

    Lists of clinical codes are the foundation for research undertaken using electronic medical records (EMRs). If clinical code lists are not available, reviewers are unable to determine the validity of research, full study replication is impossible, researchers are unable to make effective comparisons between studies, and the construction of new code lists is subject to much duplication of effort. Despite this, the publication of clinical codes is rarely if ever a requirement for obtaining grants, validating protocols, or publishing research. In a representative sample of 450 EMR primary research articles indexed on PubMed, we found that only 19 (5.1%) were accompanied by a full set of published clinical codes and 32 (8.6%) stated that code lists were available on request. To help address these problems, we have built an online repository where researchers using EMRs can upload and download lists of clinical codes. The repository will enable clinical researchers to better validate EMR studies, build on previous code lists and compare disease definitions across studies. It will also assist health informaticians in replicating database studies, tracking changes in disease definitions or clinical coding practice through time and sharing clinical code information across platforms and data sources as research objects.

  1. Validity of Basic Electronic 1 Module Integrated Character Value Based on Conceptual Change Teaching Model to Increase Students Physics Competency in STKIP PGRI West Sumatera

    Science.gov (United States)

    Hidayati, A.; Rahmi, A.; Yohandri; Ratnawulan

    2018-04-01

    The importance of teaching materials in accordance with the characteristics of students became the main reason for the development of basic electronics I module integrated character values based on conceptual change teaching model. The module development in this research follows the development procedure of Plomp which includes preliminary research, prototyping phase and assessment phase. In the first year of this research, the module is validated. Content validity is seen from the conformity of the module with the development theory in accordance with the demands of learning model characteristics. The validity of the construct is seen from the linkage and consistency of each module component developed with the characteristic of the integrated learning model of character values obtained through validator assessment. The average validation value assessed by the validator belongs to a very valid category. Based on the validator assessment then revised the basic electronics I module integrated character values based on conceptual change teaching model.

  2. The validity of Cloze Oriented System (COS: a correlation study with an electronic comprehension test and a reading attitude survey

    Directory of Open Access Journals (Sweden)

    Maria Cristina Rodrigues Azevedo Joly

    Full Text Available This study aimed to analyze the efficiency of the Cloze Oriented System (COS considering its relation with reading attitude and its validity. The Electronic Program Comprehension (EPC for students from K1 to K4 based on the COS parts of stories from the Brazilian Children's literature was applied in eighteen class-hours. The 40 subjects, ten in each grade, of both genders aged 7 to 11 years, were evaluated before and after the EPC with a Cloze test. They answered the Elementary Reading Attitude Survey too, in a printed protocol adapted to Portuguese, to evaluate the reading attitude of the students and the influence of the EPC in the academic and recreational reading. The results showed that the performance in reading comprehension of all the subjects was higher after taking part in the EPC, and also had significant differences in reading attitude, according to the results of the T of Wilcoxon statistic test. A correlation between comprehension performance before and after the EPC and the reading attitude was verified. There was significant difference for academic reading attitude in the post-test between proficient readers and the one's that has low skill.

  3. Validity of the Prescriber Information in the Danish National Prescription Registry

    DEFF Research Database (Denmark)

    Rasmussen, Lotte; Valentin, Julie; Gesser, Katarina Margareta

    2016-01-01

    The aim of this study was to measure the validity of the prescriber information recorded in the Danish National Prescription Registry (DNPR). The prescriber information recorded in the pharmacies' electronic dispensing system was considered to represent the prescriber information recorded...... in the DNPR. Further, the problem of validity of the prescriber information pertains only to non-electronic prescriptions, as these are manually entered into the dispensing system. The recorded prescriber information was thus validated against information from a total of 2,000 non-electronic prescriptions...... at five Danish community pharmacies. The validity of the recorded prescriber information was measured at the level of the individual prescriber and the prescriber type, respectively. The proportion of non-electronic prescriptions with incorrect registrations was 22.4% (95% Confidence Interval (CI): 20...

  4. Copenhagen Psychosocial Questionnaire - A validation study using the Job Demand-Resources model.

    Science.gov (United States)

    Berthelsen, Hanne; Hakanen, Jari J; Westerlund, Hugo

    2018-01-01

    This study aims at investigating the nomological validity of the Copenhagen Psychosocial Questionnaire (COPSOQ II) by using an extension of the Job Demands-Resources (JD-R) model with aspects of work ability as outcome. The study design is cross-sectional. All staff working at public dental organizations in four regions of Sweden were invited to complete an electronic questionnaire (75% response rate, n = 1345). The questionnaire was based on COPSOQ II scales, the Utrecht Work Engagement scale, and the one-item Work Ability Score in combination with a proprietary item. The data was analysed by Structural Equation Modelling. This study contributed to the literature by showing that: A) The scale characteristics were satisfactory and the construct validity of COPSOQ instrument could be integrated in the JD-R framework; B) Job resources arising from leadership may be a driver of the two processes included in the JD-R model; and C) Both the health impairment and motivational processes were associated with WA, and the results suggested that leadership may impact WA, in particularly by securing task resources. In conclusion, the nomological validity of COPSOQ was supported as the JD-R model-can be operationalized by the instrument. This may be helpful for transferral of complex survey results and work life theories to practitioners in the field.

  5. The measurement, control, and validation of critical parameters in an electron beam sterilization facility

    International Nuclear Information System (INIS)

    Burns, P.; Drewell, N.H.; McKeown, J.

    1996-01-01

    The delivery and validation of a specified dose to a medical device are key concerns of operators of electron beam irradiation facilities. In an IMPELA-based irradiator, four of the parameters that directly influence the absorbed dose distribution in the product are controllable in real time - the electron energy, average beam current, scanned area, and the product exposure time. The 10 MeV accelerator operates at 50 kW with a stream of 200 μs wide, 100 mA pulses at a repetition rate of 250 Hz. The combination of short-term intra-pulse regulation with long-term pulse-to-pulse stability makes the IMPELA output attractive for the sterilization of medical products. The measurement and closed-loop control techniques used in the IMPELA design will be described with reference to facilitating compliance with medical sterilization standards. (orig.)

  6. NVN 5694 intra laboratory validation. Feasibility study for interlaboratory- validation

    International Nuclear Information System (INIS)

    Voors, P.I.; Baard, J.H.

    1998-11-01

    Within the project NORMSTAR 2 a number of Dutch prenormative protocols have been defined for radioactivity measurements. Some of these protocols, e.g. the Dutch prenormative protocol NVN 5694, titled Methods for radiochemical determination of polonium-210 and lead-210, have not been validated, neither by intralaboratory nor interlaboratory studies. Validation studies are conducted within the framework of the programme 'Normalisatie and Validatie van Milieumethoden 1993-1997' (Standardization and Validation of test methods for environmental parameters) of the Dutch Ministry of Housing, Physical Planning and the Environment (VROM). The aims of this study were (a) a critical evaluation of the protocol, (b) investigation on the feasibility of an interlaboratory study, and (c) the interlaboratory validation of NVN 5694. The evaluation of the protocol resulted in a list of deficiencies varying from missing references to incorrect formulae. From the survey by interview it appeared that for each type of material, there are 4 to 7 laboratories willing to participate in a interlaboratory validation study. This reflects the situation in 1997. Consequently, if 4 or 6 (the minimal number) laboratories are participating and each laboratory analyses 3 subsamples, the uncertainty in the repeatability standard deviation is 49 or 40 %, respectively. If the ratio of reproducibility standard deviation to the repeatability standard deviation is equal to 1 or 2, then the uncertainty in the reproducibility standard deviation increases from 42 to 67 % and from 34 to 52 % for 4 or 6 laboratories, respectively. The intralaboratory validation was established on four different types of materials. Three types of materials (milkpowder condensate and filter) were prepared in the laboratory using the raw material and certified Pb-210 solutions, and one (sediment) was obtained from the IAEA. The ECN-prepared reference materials were used after testing on homogeneity. The pre-normative protocol can

  7. A Complete Reporting of MCNP6 Validation Results for Electron Energy Deposition in Single-Layer Extended Media for Source Energies <= 1-MeV

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hughes, Henry Grady [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-04

    In this paper, we expand on previous validation work by Dixon and Hughes. That is, we present a more complete suite of validation results with respect to to the well-known Lockwood energy deposition experiment. Lockwood et al. measured energy deposition in materials including beryllium, carbon, aluminum, iron, copper, molybdenum, tantalum, and uranium, for both single- and multi-layer 1-D geometries. Source configurations included mono-energetic, mono-directional electron beams with energies of 0.05-MeV, 0.1-MeV, 0.3- MeV, 0.5-MeV, and 1-MeV, in both normal and off-normal angles of incidence. These experiments are particularly valuable for validating electron transport codes, because they are closely represented by simulating pencil beams incident on 1-D semi-infinite slabs with and without material interfaces. Herein, we include total energy deposition and energy deposition profiles for the single-layer experiments reported by Lockwood et al. (a more complete multi-layer validation will follow in another report).

  8. Student Off-Task Electronic Multitasking Predictors: Scale Development and Validation

    Science.gov (United States)

    Qian, Yuxia; Li, Li

    2017-01-01

    In an attempt to better understand factors contributing to students' off-task electronic multitasking behavior in class, the research included two studies that developed a scale of students' off-task electronic multitasking predictors (the SOTEMP scale), and explored relationships between the scale and various classroom communication processes and…

  9. Study of cerenkov radiation. Production of {gamma} rays by electron accelerators; Etude du rayonnement de freinage. Production de rayons {gamma} par des accelerateurs d'electrons

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This study is a critical comparison of the theories of Bremsstrahlung. Experimental results obtained by the production of {gamma} radiation with electron accelerators are compared to the theoretical results in order to estimate the extent to which the various theories are valid. (author) [French] Cette etude est une synthese des theories du rayonnement de freinage. Des resultats experimentaux, obtenus par la production de rayonnements {gamma} avec des accelerateurs d'electrons, sont compares aux resultats theoriques afin d'evaluer les domaines de validite des diverses theories. (auteur)

  10. Italian version of Dyspnoea-12: cultural-linguistic validation, quantitative and qualitative content validity study.

    Science.gov (United States)

    Caruso, Rosario; Arrigoni, Cristina; Groppelli, Katia; Magon, Arianna; Dellafiore, Federica; Pittella, Francesco; Grugnetti, Anna Maria; Chessa, Massimo; Yorke, Janelle

    2018-01-16

    Dyspnoea-12 is a valid and reliable scale to assess dyspneic symptom, considering its severity, physical and emotional components. However, it is not available in Italian version due to it was not yet translated and validated. For this reason, the aim of this study was to develop an Italian version Dyspnoea-12, providing a cultural and linguistic validation, supported by the quantitative and qualitative content validity. This was a methodological study, divided into two phases: phase one is related to the cultural and linguistic validation, phase two is related to test the quantitative and qualitative content validity. Linguistic validation followed a standardized translation process. Quantitative content validity was assessed computing content validity ratio (CVR) and index (I-CVIs and S-CVI) from expert panellists response. Qualitative content validity was assessed by the narrative analysis on the answers of three open-ended questions to the expert panellists, aimed to investigate the clarity and the pertinence of the Italian items. The translation process found a good agreement in considering clear the items in both the six involved bilingual expert translators and among the ten voluntary involved patients. CVR, I-CVIs and S-CVI were satisfactory for all the translated items. This study has represented a pivotal step to use Dyspnoea-12 amongst Italian patients. Future researches are needed to deeply investigate the Italian version of  Dyspnoea-12 construct validity and its reliability, and to describe how dyspnoea components (i.e. physical and emotional) impact the life of patients with cardiorespiratory diseases.

  11. Copenhagen Psychosocial Questionnaire - A validation study using the Job Demand-Resources model.

    Directory of Open Access Journals (Sweden)

    Hanne Berthelsen

    Full Text Available This study aims at investigating the nomological validity of the Copenhagen Psychosocial Questionnaire (COPSOQ II by using an extension of the Job Demands-Resources (JD-R model with aspects of work ability as outcome.The study design is cross-sectional. All staff working at public dental organizations in four regions of Sweden were invited to complete an electronic questionnaire (75% response rate, n = 1345. The questionnaire was based on COPSOQ II scales, the Utrecht Work Engagement scale, and the one-item Work Ability Score in combination with a proprietary item. The data was analysed by Structural Equation Modelling.This study contributed to the literature by showing that: A The scale characteristics were satisfactory and the construct validity of COPSOQ instrument could be integrated in the JD-R framework; B Job resources arising from leadership may be a driver of the two processes included in the JD-R model; and C Both the health impairment and motivational processes were associated with WA, and the results suggested that leadership may impact WA, in particularly by securing task resources.In conclusion, the nomological validity of COPSOQ was supported as the JD-R model-can be operationalized by the instrument. This may be helpful for transferral of complex survey results and work life theories to practitioners in the field.

  12. Lesson 6: Signature Validation

    Science.gov (United States)

    Checklist items 13 through 17 are grouped under the Signature Validation Process, and represent CROMERR requirements that the system must satisfy as part of ensuring that electronic signatures it receives are valid.

  13. Oblique electron cyclotron emission for electron distribution studies (invited)

    International Nuclear Information System (INIS)

    Preische, S.; Efthimion, P.C.; Kaye, S.M.

    1997-01-01

    Electron cyclotron emission (ECE) at an oblique angle to the magnetic field provides a means of probing the electron distribution function both in energy and physical space through changes in and constraints on the relativistic electron cyclotron resonance condition. Diagnostics based on this Doppler shifted resonance are able to study a variety of electron distributions through changes in the location of the resonance in physical or energy space accomplished by changes in the viewing angle and frequency, and the magnetic field. For the case of observation across a changing magnetic field, such as across the tokamak midplane, the constraint on the resonance condition for real solutions to the dispersion relation can constrain the physical location of optically thin emission. A new Oblique ECE diagnostic was installed and operated on the PBX-M tokamak for the study of energetic electrons during lower hybrid current drive. It has a view 33 degree with respect to perpendicular in the tokamak midplane, receives second harmonic X-mode emission, and is constrained to receive single pass emission by SiC viewing dumps on the tokamak walls. Spatial localization of optically thin emission from superthermal electrons (50 endash 100 keV) was obtained by observation of emission upshifted from a thermal cyclotron harmonic. The localized measurements of the electron energy distribution and the superthermal density profile made by this diagnostic demonstrate its potential to study the spatial transport of energetic electrons on fast magnetohydrodynamic time scales or anomalous diffusion time scales. Oblique ECE can also be used to study electron distributions that may have a slight deviation from a Maxwellian by localizing the emission in energy space. (Abstract Truncated)

  14. Molecular dynamics-based refinement and validation for sub-5 Å cryo-electron microscopy maps.

    Science.gov (United States)

    Singharoy, Abhishek; Teo, Ivan; McGreevy, Ryan; Stone, John E; Zhao, Jianhua; Schulten, Klaus

    2016-07-07

    Two structure determination methods, based on the molecular dynamics flexible fitting (MDFF) paradigm, are presented that resolve sub-5 Å cryo-electron microscopy (EM) maps with either single structures or ensembles of such structures. The methods, denoted cascade MDFF and resolution exchange MDFF, sequentially re-refine a search model against a series of maps of progressively higher resolutions, which ends with the original experimental resolution. Application of sequential re-refinement enables MDFF to achieve a radius of convergence of ~25 Å demonstrated with the accurate modeling of β-galactosidase and TRPV1 proteins at 3.2 Å and 3.4 Å resolution, respectively. The MDFF refinements uniquely offer map-model validation and B-factor determination criteria based on the inherent dynamics of the macromolecules studied, captured by means of local root mean square fluctuations. The MDFF tools described are available to researchers through an easy-to-use and cost-effective cloud computing resource on Amazon Web Services.

  15. Study of single-electron excitations by electron microscopy

    International Nuclear Information System (INIS)

    Craven, A.J.; Gibson, J.M.; Howie, A.; Spalding, D.R.

    1978-01-01

    The inelastic scattering of fast electrons by the excitation of L-shell electrons at a stacking fault in silicon has been studied with a scanning transmission electron microscope. It was found that the bright-field stacking fault contrast is preserved in the filtered L-shell-loss signal at 100 eV. This result is discussed in terms of the delocalization of the excitation mechanism. It is concluded that localization effects will typically become significant only for energy transfers greater than 1 keV from a fast electron of energy 80 keV. (author)

  16. Theoretical Studies of TE-Wave Propagation as a Diagnostic for Electron Cloud

    International Nuclear Information System (INIS)

    Penn, Gregory E.; Vay, Jean-Luc

    2010-01-01

    The propagation of TE waves is sensitive to the presence of an electron cloud primarily through phase shifts generated by the altered dielectric function, but can also lead to polarization changes and other effects, especially in the presence of magnetic fields. These effects are studied theoretically and also through simulations using WARP. Examples are shown related to CesrTA parameters, and used to observe different regimes of operation as well as to validate estimates of the phase shift.

  17. Validation studies of nursing diagnoses in neonatology

    Directory of Open Access Journals (Sweden)

    Pavlína Rabasová

    2016-03-01

    Full Text Available Aim: The objective of the review was the analysis of Czech and foreign literature sources and professional periodicals to obtain a relevant comprehensive overview of validation studies of nursing diagnoses in neonatology. Design: Review. Methods: The selection criterion was studies concerning the validation of nursing diagnoses in neonatology. To obtain data from relevant sources, the licensed professional databases EBSCO, Web of Science and Scopus were utilized. The search criteria were: date of publication - unlimited; academic periodicals - full text; peer-reviewed periodicals; search language - English, Czech and Slovak. Results: A total of 788 studies were found. Only 5 studies were eligible for content analysis, dealing specifically with validation of nursing diagnoses in neonatology. The analysis of the retrieved studies suggests that authors are most often concerned with identifying the defining characteristics of nursing diagnoses applicable to both the mother (parents and the newborn. The diagnoses were validated in the domains Role Relationship; Coping/Stress tolerance; Activity/Rest, and Elimination and Exchange. Diagnoses represented were from the field of dysfunctional physical needs as well as the field of psychosocial and spiritual needs. The diagnoses were as follows: Parental role conflict (00064; Impaired parenting (00056; Grieving (00136; Ineffective breathing pattern (00032; Impaired gas exchange (00030; and Impaired spontaneous ventilation (00033. Conclusion: Validation studies enable effective planning of interventions with measurable results and support clinical nursing practice.

  18. Experimental study of fast electron transport in the framework of fast ignition for inertial fusion

    International Nuclear Information System (INIS)

    Vauzour, B.

    2012-01-01

    The framework of this PhD thesis is the validation of the fast ignition scheme for the nuclear fusion by inertial confinement. It consists in the experimental study of the various processes involved in fast electron beams propagation, produced by intense laser pulses (10 19 W.cm -2 ), through dense matter either solid or compressed. In this work we present the results of three experiments carried out on different laser facilities in order to generate fast electron beams in various conditions and study their propagation in different states of matter, from the cold solid to the warm and dense plasma.The first experiment was performed with a high intensity contrast on the UHI100 laser facility (CEA Saclay). The study of fast electron energy deposition inside thin aluminium targets highlights a strong target heating at shallow depths, where the collective effects are predominant, thus producing a steep temperature profile between front (300 eV) and rear (20 eV) sides over 20μm thickness. A numerical simulation of the experiment shows that this temperature gradient induces the formation of a shock wave, breaking through the rear side of the target and thus leading to increase the thermal emission. The experimental chronometry of the shock breakthrough allowed validating the model of the collective transport of electrons.Two other experiments were dedicated to the study of fast electron beam propagation inside compressed targets. In the first experiment on the LULI2000 laser facility, the plane compression geometry allowed to precisely dissociate the energy losses due to resistive effects from those due to the collisional ones. By comparing our experimental results with simulations, we observed a significative increase of the fast electron beam energy losses with the compression and the target heating to temperatures close to the Fermi temperature. The second experiment, performed in a cylindrical geometry, demonstrated a fast electron beam guiding phenomenon due to

  19. Efficacy and External Validity of Electronic and Mobile Phone-Based Interventions Promoting Vegetable Intake in Young Adults: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Nour, Monica; Chen, Juliana; Allman-Farinelli, Margaret

    2016-04-08

    Young adults (18-35 years) remain among the lowest vegetable consumers in many western countries. The digital era offers opportunities to engage this age group in interventions in new and appealing ways. This systematic review evaluated the efficacy and external validity of electronic (eHealth) and mobile phone (mHealth) -based interventions that promote vegetable intake in young adults. We searched several electronic databases for studies published between 1990 and 2015, and 2 independent authors reviewed the quality and risk of bias of the eligible papers and extracted data for analyses. The primary outcome of interest was the change in vegetable intake postintervention. Where possible, we calculated effect sizes (Cohen d and 95% CIs) for comparison. A random effects model was applied to the data for meta-analysis. Reach and representativeness of participants, intervention implementation, and program maintenance were assessed to establish external validity. Published validation studies were consulted to determine the validity of tools used to measure intake. We applied the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system to evaluate the overall quality of the body of evidence. Of the 14 studies that met the selection criteria, we included 12 in the meta-analysis. In the meta-analysis, 7 studies found positive effects postintervention for fruit and vegetable intake, Cohen d 0.14-0.56 (pooled effect size 0.22, 95% CI 0.11-0.33, I(2)=68.5%, P=.002), and 4 recorded positive effects on vegetable intake alone, Cohen d 0.11-0.40 (pooled effect size 0.15, 95% CI 0.04-0.28, I(2)=31.4%, P=.2). These findings should be interpreted with caution due to variability in intervention design and outcome measures. With the majority of outcomes documented as a change in combined fruit and vegetable intake, it was difficult to determine intervention effects on vegetable consumption specifically. Measurement of intake was most commonly by self

  20. Validation of cell-free culture using scanning electron microscopy (SEM) and gene expression studies.

    Science.gov (United States)

    Yang, R; Elankumaran, Y; Hijjawi, N; Ryan, U

    2015-06-01

    A cell-free culture system for Cryptosporidium parvum was analysed using scanning electron microscopy (SEM) to characterise life cycle stages and compare gene expression in cell-free culture and cell culture using HCT-8 cells. Cryptosporidium parvum samples were harvested at 2 h, 8 h, 14 h, 26 h, 50 h, 74 h, 98 h, 122 h and 170 h, chemically fixed and specimens were observed using a Zeiss 1555 scanning electron microscope. The presence of sporozoites, trophozoites and type I merozoites were identified by SEM. Gene expression in cell culture and cell-free culture was studied using reverse transcriptase quantitative PCR (RT-qPCR) of the sporozoite surface antigen protein (cp15), the glycoprotein 900 (gp900), the Cryptosporidium oocyst wall protein (COWP) and 18S ribosomal RNA (rRNA) genes in both cell free and conventional cell culture. In cell culture, cp15 expression peaked at 74 h, gp900 expression peaked at 74 h and 98 h and COWP expression peaked at 50 h. In cell-free culture, CP15 expression peaked at 98 h, gp900 expression peaked at 74 h and COWP expression peaked at 122 h. The present study is the first to compare gene expression of C. parvum in cell culture and cell-free culture and to characterise life cycle stages of C. parvum in cell-free culture using SEM. Findings from this study showed that gene expression patterns in cell culture and cell-free culture were similar but in cell-free culture, gene expression was delayed for CP15 and COWP in cell free culture compared with the cell culture system and was lower. Although three life cycle stageswere conclusively identified, improvements in SEM methodology should lead to the detection of more life cycle stages. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Using wound care algorithms: a content validation study.

    Science.gov (United States)

    Beitz, J M; van Rijswijk, L

    1999-09-01

    Valid and reliable heuristic devices facilitating optimal wound care are lacking. The objectives of this study were to establish content validation data for a set of wound care algorithms, to identify their associated strengths and weaknesses, and to gain insight into the wound care decision-making process. Forty-four registered nurse wound care experts were surveyed and interviewed at national and regional educational meetings. Using a cross-sectional study design and an 83-item, 4-point Likert-type scale, this purposive sample was asked to quantify the degree of validity of the algorithms' decisions and components. Participants' comments were tape-recorded, transcribed, and themes were derived. On a scale of 1 to 4, the mean score of the entire instrument was 3.47 (SD +/- 0.87), the instrument's Content Validity Index was 0.86, and the individual Content Validity Index of 34 of 44 participants was > 0.8. Item scores were lower for those related to packing deep wounds (P valid and reliable definitions. The wound care algorithms studied proved valid. However, the lack of valid and reliable wound assessment and care definitions hinders optimal use of these instruments. Further research documenting their clinical use is warranted. Research-based practice recommendations should direct the development of future valid and reliable algorithms designed to help nurses provide optimal wound care.

  2. Online Prediction of Health Care Utilization in the Next Six Months Based on Electronic Health Record Information: A Cohort and Validation Study.

    Science.gov (United States)

    Hu, Zhongkai; Hao, Shiying; Jin, Bo; Shin, Andrew Young; Zhu, Chunqing; Huang, Min; Wang, Yue; Zheng, Le; Dai, Dorothy; Culver, Devore S; Alfreds, Shaun T; Rogow, Todd; Stearns, Frank; Sylvester, Karl G; Widen, Eric; Ling, Xuefeng

    2015-09-22

    The increasing rate of health care expenditures in the United States has placed a significant burden on the nation's economy. Predicting future health care utilization of patients can provide useful information to better understand and manage overall health care deliveries and clinical resource allocation. This study developed an electronic medical record (EMR)-based online risk model predictive of resource utilization for patients in Maine in the next 6 months across all payers, all diseases, and all demographic groups. In the HealthInfoNet, Maine's health information exchange (HIE), a retrospective cohort of 1,273,114 patients was constructed with the preceding 12-month EMR. Each patient's next 6-month (between January 1, 2013 and June 30, 2013) health care resource utilization was retrospectively scored ranging from 0 to 100 and a decision tree-based predictive model was developed. Our model was later integrated in the Maine HIE population exploration system to allow a prospective validation analysis of 1,358,153 patients by forecasting their next 6-month risk of resource utilization between July 1, 2013 and December 31, 2013. Prospectively predicted risks, on either an individual level or a population (per 1000 patients) level, were consistent with the next 6-month resource utilization distributions and the clinical patterns at the population level. Results demonstrated the strong correlation between its care resource utilization and our risk scores, supporting the effectiveness of our model. With the online population risk monitoring enterprise dashboards, the effectiveness of the predictive algorithm has been validated by clinicians and caregivers in the State of Maine. The model and associated online applications were designed for tracking the evolving nature of total population risk, in a longitudinal manner, for health care resource utilization. It will enable more effective care management strategies driving improved patient outcomes.

  3. Validation of exhaled volatile organic compounds analysis using electronic nose as index of COPD severity

    Directory of Open Access Journals (Sweden)

    Finamore P

    2018-05-01

    Full Text Available Panaiotis Finamore,1 Claudio Pedone,1 Simone Scarlata,1 Alessandra Di Paolo,1 Simone Grasso,2 Marco Santonico,2 Giorgio Pennazza,2 Raffaele Antonelli Incalzi1 1Unit of Geriatrics, Campus Bio-Medico di Roma University, Rome, Italy; 2Unit of Electronics for Sensor Systems, Campus Bio-Medico di Roma University, Rome, Italy Aim: Six-minute walking test distance (6MWD and body mass index, obstruction, dyspnea and exercise (BODE index are measures of functional status in COPD patients, but require space, time and patient’s compliance. Exhaled volatile organic compounds (VOCs analysis via electronic nose is a quick and easy method that has already been used to discriminate COPD phenotypes. The aim of this study is to evaluate whether VOCs analysis can predict functional status and its variation over time in COPD patients.Methods: A monocentric prospective study with 1 year of follow-up was carried out. All patients underwent pulmonary function tests, arterial gas analysis, bioimpedance analysis, 6-minute walking test, and VOCs collection. Exhaled breath was collected with Pneumopipe® and analyzed using BIONOTE electronic nose. Outcomes prediction was performed by k-fold cross-validated partial least square discriminant analysis: accuracy, sensitivity and specificity as well as Cohen’s kappa for agreement were calculated.Results: We enrolled 63 patients, 60.3% men, with a mean age of 71 (SD: 8 years, median BODE index of 1 (interquartile range: 0–3 and mean 6MWD normalized by squared height (n6MWD of 133.5 (SD: 42 m/m2. The BIONOTE predicted baseline BODE score (dichotomized as BODE score <3 or ≥3 with an accuracy of 86% and quartiles of n6MWD with an accuracy of 79%. n6MWD decline more than the median value after 1 year was predicted with an accuracy of 86% by BIONOTE, 52% by Global Initiative for Chronic Obstructive Lung Disease (GOLD class and 78% by combined BIONOTE and GOLD class.Conclusion: Exhaled VOCs analysis identifies classes of BODE

  4. Multiprofissional electronic protocol in ophtalmology with enfasis in strabismus

    Directory of Open Access Journals (Sweden)

    CHRISTIE GRAF RIBEIRO

    Full Text Available ABSTRACT Objective: to create and validate an electronic database in ophthalmology focused on strabismus, to computerize this database in the form of a systematic data collection software named Electronic Protocol, and to incorporate this protocol into the Integrated System of Electronic Protocols (SINPE(c. Methods: this is a descriptive study, with the methodology divided into three phases: (1 development of a theoretical ophthalmologic database with emphasis on strabismus; (2 computerization of this theoretical ophthalmologic database using SINPE(c and (3 interpretation of the information with demonstration of results to validate the protocol. We inputed data from the charts of fifty patients with known strabismus through the Electronic Protocol for testing and validation. Results: the new electronic protocol was able to store information regarding patient history, physical examination, laboratory exams, imaging results, diagnosis and treatment of patients with ophthalmologic diseases, with emphasis on strabismus. We included 2,141 items in this master protocol and created 20 new specific electronic protocols for strabismus, each with its own specifics. Validation was achieved through correlation and corroboration of the symptoms and confirmed diagnoses of the fifty included patients with the diagnostic criteria for the twenty new strabismus protocols. Conclusion: a new, validated electronic database focusing on ophthalmology, with emphasis on strabismus, was successfully created through the standardized collection of information, and computerization of the database using proprietary software. This protocol is ready for deployment to facilitate data collection, sorting and application for practitioners and researchers in numerous specialties.

  5. Implementation of the validation testing in MPPG 5.a "Commissioning and QA of treatment planning dose calculations-megavoltage photon and electron beams".

    Science.gov (United States)

    Jacqmin, Dustin J; Bredfeldt, Jeremy S; Frigo, Sean P; Smilowitz, Jennifer B

    2017-01-01

    The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analysis tools to deliver and analyze the validation tests. This included the development of a novel, open-source software tool to compare scanning water tank measurements to 3D DICOM-RT Dose distributions. Dose calculation algorithms in both Pinnacle and Eclipse were tested with MPPG 5.a to validate the modeling of Varian TrueBeam linear accelerators. The validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (TPS). Overall, the validation testing recommended in MPPG 5.a took approximately 79 person-hours for a machine with four photon and five electron energies for a single TPS. Of the 79 person-hours, 26 person-hours required time on the machine, and the remainder involved preparation and analysis. The basic photon, electron, and heterogeneity correction tests were evaluated with the tolerances in MPPG 5.a, and the tolerances were met for all tests. The MPPG 5.a evaluation criteria were used to assess the small field and IMRT/VMAT validation tests. Both institutions found the use of MPPG 5.a to be a valuable resource during the commissioning process. The validation testing in MPPG 5.a showed the strengths and limitations of the TPS models. In addition, the data collected during the validation testing is useful for routine QA of the TPS, validation of software upgrades, and commissioning of new algorithms. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of

  6. Training and Validating a Portable Electronic Nose for Lung Cancer Screening.

    Science.gov (United States)

    van de Goor, Rens; van Hooren, Michel; Dingemans, Anne-Marie; Kremer, Bernd; Kross, Kenneth

    2018-05-01

    Profiling volatile organic compounds in exhaled breath enables the diagnosis of several types of cancer. In this study we investigated whether a portable point-of-care version of an electronic nose (e-nose) (Aeonose, [eNose Company, Zutphen, the Netherlands]) is able to discriminate between patients with lung cancer and healthy controls on the basis of their volatile organic compound pattern. In this study, we used five e-nose devices to collect breath samples from patients with lung cancer and healthy controls. A total of 60 patients with lung cancer and 107 controls exhaled through an e-nose for 5 minutes. Patients were assigned either to a training group for building an artificial neural network model or to a blinded control group for validating this model. For differentiating patients with lung cancer from healthy controls, the results showed a diagnostic accuracy of 83% with a sensitivity of 83%, specificity of 84%, and area under the curve of 0.84. Results for the blinded group showed comparable results, with a sensitivity of 88%, specificity of 86%, and diagnostic accuracy of 86%. This feasibility study showed that this portable e-nose can properly differentiate between patients with lung cancer and healthy controls. This result could have important implications for future lung cancer screening. Further studies with larger cohorts, including also more participants with early-stage tumors, should be performed to increase the robustness of this noninvasive diagnostic tool and to determine its added value in the diagnostic chain for lung cancer. Copyright © 2018 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  7. Benchmarking NaI(Tl) Electron Energy Resolution Measurements

    International Nuclear Information System (INIS)

    Mengesha, Wondwosen; Valentine, J D.

    2002-01-01

    A technique for validating electron energy resolution results measured using the modified Compton coincidence technique (MCCT) has been developed. This technique relies on comparing measured gamma-ray energy resolution with calculated values that were determined using the measured electron energy resolution results. These gamma-ray energy resolution calculations were based on Monte Carlo photon transport simulations, the measured NaI(Tl) electron response, a simplified cascade sequence, and the measured electron energy resolution results. To demonstrate this technique, MCCT-measured NaI(Tl) electron energy resolution results were used along with measured gamma-ray energy resolution results from the same NaI(Tl) crystal. Agreement to within 5% was observed for all energies considered between the calculated and measured gamma-ray energy resolution results for the NaI(Tl) crystal characterized. The calculated gamma-ray energy resolution results were also compared with previously published gamma-ray energy resolution measurements with good agreement (<10%). In addition to describing the validation technique that was developed in this study and the results, a brief review of the electron energy resolution measurements made using the MCCT is provided. Based on the results of this study, it is believed that the MCCT-measured electron energy resolution results are reliable. Thus, the MCCT and this validation technique can be used in the future to characterize the electron energy resolution of other scintillators and to determine NaI(Tl) intrinsic energy resolution

  8. Studying electron-PAG interactions using electron-induced fluorescence

    Science.gov (United States)

    Narasimhan, Amrit; Grzeskowiak, Steven; Ostrander, Jonathan; Schad, Jonathon; Rebeyev, Eliran; Neisser, Mark; Ocola, Leonidas E.; Denbeaux, Gregory; Brainard, Robert L.

    2016-03-01

    In extreme ultraviolet (EUV) lithography, 92 eV photons are used to expose photoresists. Typical EUV resists are organic-based and chemically amplified using photoacid generators (PAGs). Upon exposure, PAGs produce acids which catalyze reactions that result in changes in solubility. In EUV lithography, photo- and secondary electrons (energies of 10- 80 eV) play a large role in PAG acid-production. Several mechanisms for electron-PAG interactions (e.g. electron trapping, and hole-initiated chemistry) have been proposed. The aim of this study is to explore another mechanism - internal excitation - in which a bound PAG electron can be excited by receiving energy from another energetic electron, causing a reaction that produces acid. This paper explores the mechanism of internal excitation through the analogous process of electron-induced fluorescence, in which an electron loses energy by transferring that energy to a molecule and that molecule emits a photon rather than decomposing. We will show and quantify electron-induced fluorescence of several fluorophores in polymer films to mimic resist materials, and use this information to refine our proposed mechanism. Relationships between the molecular structure of fluorophores and fluorescent quantum yield may aid in the development of novel PAGs for EUV lithography.

  9. Molecular studies by electron spectroscopy

    International Nuclear Information System (INIS)

    Hansteen, J.M.

    1977-01-01

    Experience gained in experimental nuclear physics has played a large role in the development of electron spectroscopy as a powerful tool for studying chemical systems. The use of ESCA (Electron Spectroscopy for Chemical Analysis) for the mapping of molecular properties connected with inner as well as outer electron shells is reviewed, mainly from a phenomological point of view. Molecular Auger electron spectroscopy is described as a means of gaining information on details in molecular structure, simultaneously being extensively applied for surface studies. Future highly promising research areas for molecular electron spectroscopy are suggested to be (e,2e) processes as well as continued exploitation of synchrotron radiation from high energy nuclear devices. (Auth.)

  10. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    OpenAIRE

    Daniel D. Reidpath; Mei Lee Ling; Shajahan Yasin; Kanason Rajagobal; Pascale Allotey

    2012-01-01

    Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers usin...

  11. Radiology Reporting System Data Exchange With the Electronic Health Record System: A Case Study in Iran.

    Science.gov (United States)

    Ahmadi, Maryam; Ghazisaeidi, Marjan; Bashiri, Azadeh

    2015-03-18

    In order to better designing of electronic health record system in Iran, integration of health information systems based on a common language must be done to interpret and exchange this information with this system is required. This study provides a conceptual model of radiology reporting system using unified modeling language. The proposed model can solve the problem of integration this information system with the electronic health record system. By using this model and design its service based, easily connect to electronic health record in Iran and facilitate transfer radiology report data. This is a cross-sectional study that was conducted in 2013. The study population was 22 experts that working at the Imaging Center in Imam Khomeini Hospital in Tehran and the sample was accorded with the community. Research tool was a questionnaire that prepared by the researcher to determine the information requirements. Content validity and test-retest method was used to measure validity and reliability of questioner respectively. Data analyzed with average index, using SPSS. Also Visual Paradigm software was used to design a conceptual model. Based on the requirements assessment of experts and related texts, administrative, demographic and clinical data and radiological examination results and if the anesthesia procedure performed, anesthesia data suggested as minimum data set for radiology report and based it class diagram designed. Also by identifying radiology reporting system process, use case was drawn. According to the application of radiology reports in electronic health record system for diagnosing and managing of clinical problem of the patient, with providing the conceptual Model for radiology reporting system; in order to systematically design it, the problem of data sharing between these systems and electronic health records system would eliminate.

  12. Library usage patterns in the electronic information environment. Electronic journals, Use studies, Libraries, Medical libraries

    Directory of Open Access Journals (Sweden)

    B. Franklin

    2004-01-01

    Full Text Available This paper examines the methodology and results from Web-based surveys of more than 15,000 networked electronic services users in the United States between July 1998 and June 2003 at four academic health sciences libraries and two large main campus libraries serving a variety of disciplines. A statistically valid methodology for administering simultaneous Web-based and print-based surveys using the random moments sampling technique is discussed and implemented. Results from the Web-based surveys showed that at the four academic health sciences libraries, there were approximately four remote networked electronic services users for each in-house user. This ratio was even higher for faculty, staff, and research fellows at the academic health sciences libraries, where more than five remote users for each in-house user were recorded. At the two main libraries, there were approximately 1.3 remote users for each in-house user of electronic information. Sponsored research (grant funded research accounted for approximately 32% of the networked electronic services activity at the health sciences libraries and 16% at the main campus libraries. Sponsored researchers at the health sciences libraries appeared to use networked electronic services most intensively from on-campus, but not from in the library. The purpose of use for networked electronic resources by patrons within the library is different from the purpose of use of those resources by patrons using the resources remotely. The implications of these results on how librarians reach decisions about networked electronic resources and services are discussed.

  13. Millisecond resolution electron fluxes from the Cluster satellites: Calibrated EDI ambient electron data

    Science.gov (United States)

    Förster, Matthias; Rashev, Mikhail; Haaland, Stein

    2017-04-01

    The Electron Drift Instrument (EDI) onboard Cluster can measure 500 eV and 1 keV electron fluxes with high time resolution during passive operation phases in its Ambient Electron (AE) mode. Data from this mode is available in the Cluster Science Archive since October 2004 with a cadence of 16 Hz in the normal mode or 128 Hz for burst mode telemetry intervals. The fluxes are recorded at pitch angles of 0, 90, and 180 degrees. This paper describes the calibration and validation of these measurements. The high resolution AE data allow precise temporal and spatial diagnostics of magnetospheric boundaries and will be used for case studies and statistical studies of low energy electron fluxes in the near-Earth space. We show examples of applications.

  14. Validity of the use of the neutron reduction factor in assessing displacement damage to electronics in armoured vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, T.; Jamieson, T.J.

    1990-01-01

    To predict the degree of protection afforded to electronics by armoured vehicles exposed to neutron irradiation, the ratio of outside to inside tissue kermas has often been used as an approximation. This report examines the validity of this approximation by using the computer code VPF2 to generate neutron fields to be expected in a number of battlefield scenarios. The performance of 2 neutron dosimeters in these fields is also examined.

  15. Electronic Signature Policy

    Science.gov (United States)

    Establishes the United States Environmental Protection Agency's approach to adopting electronic signature technology and best practices to ensure electronic signatures applied to official Agency documents are legally valid and enforceable

  16. Electronics: Mott Transistor: Fundamental Studies and Device Operation Mechanisms

    Science.gov (United States)

    2016-03-21

    display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. Harvard University Office for Sponsored Programs...including journal references , in the following categories: (b) Papers published in non-peer-reviewed journals (N/A for none) 03/21/2016 03/21/2016 03...limited kinetics of electron doping in correlated oxides, Applied Physics Letters (07 2015) TOTAL: 1 Books Number of Manuscripts: Patents Submitted

  17. Social Studies by Electronic Mail.

    Science.gov (United States)

    Barr, Hugh

    1994-01-01

    Asserts that electronic mail provides opportunities to engage students actively in cross-cultural contact with students in other nations. Discusses advantages and problems with using electronic mail in the social studies classroom. Describes electronic mail projects that link students in New Zealand, England, and the United States. (CFR)

  18. Feasibility study for mega-electron-volt electron beam tomography.

    Science.gov (United States)

    Hampel, U; Bärtling, Y; Hoppe, D; Kuksanov, N; Fadeev, S; Salimov, R

    2012-09-01

    Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

  19. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1990-01-01

    Our laboratory has made significant progress this year in devising improved electron-optical systems, in studying invertebrate hemoglobins with the STEM, and in achieving a workable sub-angstrom STEM. Our goal in electron optics is to improve resolution by producing spherical and chromatic aberration coefficients with signs opposite those of magnetic lenses. We have progressed toward this goal through calculations that explore the addition of electrodes to electron mirrors to reduce these two geometric aberrations and by devising a beam separation system that won't introduce asymmetrical aberrations. Some promising new designs of magnetic lenses for SEM applications have also been investigated. We have continued our exploration of the quaternary structure of the invertebrate hemoglobins and are now among the top laboratories in this area of expertise. In addition, we have overcome many of our electronic difficulties on the sub-angstrom STEM and have made significant progress toward achieving an operational system. The addition of an IBM RISC-6000 workstation to our lab has significantly increased our image processing capabilities

  20. Experimental and theoretical study of electronic structure of aluminum in extreme conditions with X-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Festa, Floriane

    2013-01-01

    Matter in extreme conditions belongs to Warm Dense Matter regime which lays between dense plasma regime and condensed matter. This regime is still not well known, indeed it is very complex to generate such plasma in the laboratory to get experimental data and validate models. The goal of this thesis is to study electronic structure of aluminum in extreme conditions with X-ray absorption spectroscopy. Experimentally aluminum has reached high densities and high temperatures, up to now unexplored. An X-ray source has also been generated to probe highly compressed aluminum. Two spectrometers have recorded aluminum absorption spectra and aluminum density and temperature conditions have been deduced thanks to optical diagnostics. Experimental spectra have been compared to ab initio spectra, calculated in the same conditions. The theoretical goal was to validate the calculation method in high densities and high temperatures regime with the study of K-edge absorption modifications. We also used absorption spectra to study the metal-non metal transition which takes place at low density (density ≤ solid density). This transition could be study with electronic structure modifications of the system. (author) [fr

  1. Electronic study books and learning style

    NARCIS (Netherlands)

    de Diana, I.P.F.; van der Heiden, G.

    1994-01-01

    Attention has been drawn to the concepts of Electronic Books and Electronic Study Books. Several publications have discussed some main ideas (paradigms) for both concepts. For the Electronic Study Book as a learning environment, it is essential to consider individual modes of learning, usually

  2. Progress in studies of Electron-Cloud-Induced Optics Distortions at CESRTA

    International Nuclear Information System (INIS)

    Crittenden, J.A.; Calvey, J.R.; Dugan, G.F.; Kreinick, D.L.; Leong, Z.; Livezey, J.A.; Palmer, M.A.; Rubin, D.L.; Sagan, D.C.; Holtzapple, R.L.; Furman, M.A.; Penn, G.; Venturini, M.; Pivi, M.; Wang, L.; Harkay, K.

    2010-01-01

    The Cornell Electron Storage Ring Test Accelerator (CesrTA) program has included extensive measurements of coherent betatron tune shifts for a variety of electron and positron beam energies, bunch population levels, and bunch train configurations. The tune shifts have been shown to result primarily from the interaction of the beam with the space-charge field of the beam-induced low energy electron cloud in the vacuum chamber. Comparison to several advanced electron cloud simulation program packages has allowed determination of the sensitivity of these measurements to physical parameters characterizing the synchrotron radiation flux, the production of photoelectrons on the vacuum chamberwall, the beam emittance, lattice optics, and the secondary-electron yield model. We report on progress in understanding the cloud buildup and decay mechanisms in magnetic fields and in field-free regions, addressing quantitatively the precise determination of the physical parameters of the modeling. Validation of these models will serve as essential input in the design of damping rings for future high-energy linear colliders.

  3. Study the Precipitation of Radiation Belt Electrons during the Rapid Dropout Events

    Science.gov (United States)

    Tu, W.; Cunningham, G.; Li, X.; Chen, Y.

    2015-12-01

    During the main phase of storms, the relativistic electron flux in the radiation belt can drop by orders of magnitude on timescales of a few hours. Where do the electrons go? This is one of the most important outstanding questions in radiation belt studies. Radiation belt electrons can be lost either by transport across the magnetopause into interplanetary space or by precipitation into the atmosphere. In this work we first conduct a survey of the MeV electron dropouts using the Van Allen Probes data in conjunction with the low-altitude measurements of precipitating electrons by 6 NOAA/POES satellites. The dropout events are categorized into three types: precipitation-loss dominant, outward radial diffusion dominant, or with contributions from both mechanisms. The survey results suggest the relative importance of precipitation and outward radial diffusion to the fast dropouts of radiation belt electrons, and their extent in L-shell and electron energy. Then, for specific events identified as dominated by precipitation loss, we use the Drift-Diffusion model, which includes the effects of azimuthal drift and pitch angle diffusion, to simulate both the electron dropout observed by Van Allen Probes and the distributions of drift-loss-cone electrons observed by multiple low-earth-orbit satellites (6 POES and the Colorado Student Space Weather Experiment). The model quantifies the electron precipitation loss and pitch angle diffusion coefficient, Dxx, with high temporal and spatial resolution. Finally, by comparing the Dxx derived from the model with those estimated from the quasi-linear theory using wave data from Van Allen Probes and other event-specific wave models, we are able to test the validity of quasi-linear theory and seek direct evidence of the wave-particle interactions during the dropouts.

  4. World Workshop on Oral Medicine VI: an international validation study of clinical competencies for advanced training in oral medicine.

    Science.gov (United States)

    Steele, John C; Clark, Hadleigh J; Hong, Catherine H L; Jurge, Sabine; Muthukrishnan, Arvind; Kerr, A Ross; Wray, David; Prescott-Clements, Linda; Felix, David H; Sollecito, Thomas P

    2015-08-01

    To explore international consensus for the validation of clinical competencies for advanced training in Oral Medicine. An electronic survey of clinical competencies was designed. The survey was sent to and completed by identified international stakeholders during a 10-week period. To be validated, an individual competency had to achieve 90% or greater consensus to keep it in its current format. Stakeholders from 31 countries responded. High consensus agreement was achieved with 93 of 101 (92%) competencies exceeding the benchmark for agreement. Only 8 warranted further attention and were reviewed by a focus group. No additional competencies were suggested. This is the first international validated study of clinical competencies for advanced training in Oral Medicine. These validated clinical competencies could provide a model for countries developing an advanced training curriculum for Oral Medicine and also inform review of existing curricula. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Progress in Studies of Electron-Cloud-Induced Optics Distortions at CesrTA

    International Nuclear Information System (INIS)

    Crittenden, James; Penn, Gregory; Venturini, Marco; Harkay, Katherine; Holtzapple, Robert; Pivi, Mauro; Wang, Lanfa

    2012-01-01

    The Cornell Electron Storage Ring Test Accelerator (CesrTA) program has included extensive measurements of coherent betatron tune shifts for a variety of electron and positron beam energies, bunch population levels, and bunch train configurations. The tune shifts have been shown to result primarily from the interaction of the beam with the space-charge field of the beam-induced low-energy electron cloud in the vacuum chamber. Comparison to several advanced electron cloud simulation codes has allowed determination of the sensitivity of these measurements to physical parameters characterizing the synchrotron radiation flux, the production of photo-electrons on the vacuum chamber wall, the beam emittance, lattice optics, and the secondary-electron yield model. We report on progress in understanding the cloud buildup and decay mechanisms in magnetic fields and in field-free regions, addressing quantitatively the precise determination of the physical parameters of the modeling. Validation of these models will serve as essential input in the design of damping rings for future high-energy linear colliders.

  6. Secondary mineralization in carious lesions of human dentin. Electron-probe, electron microscope, and electron diffraction studies

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, H [Tokyo Dental Coll. (Japan)

    1975-02-01

    Dentinal carious lesions having a remineralized surface layer were studied by means electron-probe microanalysis, electron microscopy, electron diffraction. As the results of electron-probe study, F, Mg, and Na were found to be distributed mainly in the remineralized surface layer and S in the decalcified region where decreases in Ca, P, and Mg concentration were usually observed. The decrease in Mg concentration always started earlier than that of Ca and P concentration. Electron microscope and electron diffraction studies revealed that apatic crystals in the remineralized surface layer were much larger than those in the intact dentin. Although they were less conspicuous, crystals in the decalcified region also were larger than those in the intact region. Dentinal tubules, occluded by many crystals, were frequently seen during the observations. Crystals in the tubules varied in morphology, showing granular, needle, rhomboid, and tabular shapes. By means of electron diffraction, the granular- or needle-shaped crystals were identified as apatite and the rhomboid-shaped crystals as whitlockite. Some of the tabular-shaped crystals appeared to be cotacalcium phosphate.

  7. Validations of calibration-free measurements of electron temperature using double-pass Thomson scattering diagnostics from theoretical and experimental aspects

    Energy Technology Data Exchange (ETDEWEB)

    Tojo, H., E-mail: tojo.hiroshi@qst.go.jp; Hiratsuka, J.; Yatsuka, E.; Hatae, T.; Itami, K. [National Institutes for Quantum and Radiological Science and Technology, 801-1 Mukoyama, Naka 311-0193 (Japan); Yamada, I.; Yasuhara, R.; Funaba, H.; Hayashi, H. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Ejiri, A.; Togashi, H.; Takase, Y. [Graduate School of Frontier Sciences, The University of Tokyo, Kashiwa 277-8561 (Japan)

    2016-09-15

    This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (T{sub e}) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured T{sub e} and intensity of the signals. How accurate the values are depends on the electron temperature (T{sub e}) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high T{sub e} and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the T{sub e} in a wide T{sub e} range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the T{sub e} measurements are valid under harsh radiation conditions. This method to obtain T{sub e} can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

  8. Theoretical study of electronic and dynamic properties of simple metal clusters in jellium model

    International Nuclear Information System (INIS)

    El-Amine Madjet, M.

    1994-01-01

    We have studied the electronic properties of alkali-metal clusters in various theoretical approximations and in the framework of the spherical jellium model. We have investigated the ground state properties of alkali clusters both in the LDA (local density approximation) and in HF (Hartree-Fock) theory. We have compared the LDA predictions of the ground state properties to predictions obtained within the HF theory. Such a comparison permitted us to check the validity of the local density functional theory in describing the ground state of a finite fermion system. For the study of collective dipolar excitations in clusters, we have considered an electromagnetic excitation. We have investigated the collective modes in the following approximations: random phase approximation (RPA), time-dependent local-density approximation (TDLDA) and the sum-rules approach. An assessment of the approximation for the continuum state within the RPA is made by comparing with TDLDA calculations for the static and dynamic electronic properties. The comparative study that we have done on the exchange-correlation effects on the electronic and optical properties have shown that the discrepancies with measured data are due mostly to the jellium approximation for the ionic background. (author). 69 refs., 30 figs., 18 tabs

  9. Monte Carlo study of electron relaxation in graphene with spin polarized, degenerate electron gas in presence of electron-electron scattering

    Science.gov (United States)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-12-01

    The Monte Carlo simulation method is applied to study the relaxation of excited electrons in monolayer graphene. The presence of spin polarized background electrons population, with density corresponding to highly degenerate conditions is assumed. Formulas of electron-electron scattering rates, which properly account for electrons presence in two energetically degenerate, inequivalent valleys in this material are presented. The electron relaxation process can be divided into two phases: thermalization and cooling, which can be clearly distinguished when examining the standard deviation of electron energy distribution. The influence of the exchange effect in interactions between electrons with parallel spins is shown to be important only in transient conditions, especially during the thermalization phase.

  10. Validation of gyrokinetic simulations with measurements of electron temperature fluctuations and density-temperature phase angles on ASDEX Upgrade

    Science.gov (United States)

    Freethy, S. J.; Görler, T.; Creely, A. J.; Conway, G. D.; Denk, S. S.; Happel, T.; Koenen, C.; Hennequin, P.; White, A. E.; ASDEX Upgrade Team

    2018-05-01

    Measurements of turbulent electron temperature fluctuation amplitudes, δTe ⊥/Te , frequency spectra, and radial correlation lengths, Lr(Te ⊥) , have been performed at ASDEX Upgrade using a newly upgraded Correlation ECE diagnostic in the range of scales k⊥scale non-linear gyrokinetic turbulence simulations of the outer core (ρtor = 0.75) of a low density, electron heated L-mode plasma, performed using the gyrokinetic simulation code, GENE. The ion and electron temperature gradients were scanned within uncertainties. It is found that gyrokinetic simulations are able to match simultaneously the electron and ion heat flux at this radius within the experimental uncertainties. The simulations were performed based on a reference discharge for which δTe ⊥/Te measurements were available, and Lr(Te ⊥) and αnT were then predicted using synthetic diagnostics prior to measurements in a repeat discharge. While temperature fluctuation amplitudes are overestimated by >50% for all simulations within the sensitivity scans performed, good quantitative agreement is found for Lr(Te ⊥) and αnT. A validation metric is used to quantify the level of agreement of individual simulations with experimental measurements, and the best agreement is found close to the experimental gradient values.

  11. The validity of the 4-Skills Scan: A double validation study.

    Science.gov (United States)

    van Kernebeek, W G; de Kroon, M L A; Savelsbergh, G J P; Toussaint, H M

    2018-06-01

    Adequate gross motor skills are an essential aspect of a child's healthy development. Where physical education (PE) is part of the primary school curriculum, a strong curriculum-based emphasis on evaluation and support of motor skill development in PE is apparent. Monitoring motor development is then a task for the PE teacher. In order to fulfil this task, teachers need adequate tools. The 4-Skills Scan is a quick and easily manageable gross motor skill instrument; however, its validity has never been assessed. Therefore, the purpose of this study is to assess the construct and concurrent validity of both 4-Skills Scans (version 2007 and version 2015). A total of 212 primary school children (6 - 12 years old), was requested to participate in both versions of the 4-Skills Scan. For assessing construct validity, children covered an obstacle course with video recordings for observation by an expert panel. For concurrent validity, a comparison was made with the MABC-2, by calculating Pearson correlations. Multivariable linear regression analyses were performed to determine the contribution of each subscale to the construct of gross motor skills, according to the MABC-2 and the expert panel. Correlations between the 4-Skills Scans and expert valuations were moderate, with coefficients of .47 (version 2007) and .46 (version 2015). Correlations between the 4-Skills Scans and the MABC-2 (gross) were moderate (.56) for version 2007 and high (.64) for version 2015. It is concluded that both versions of the 4-Skills Scans are satisfactory valid instruments for assessing gross motor skills during PE lessons. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  12. Standardisation And Validation Study Of A New Study Skills ...

    African Journals Online (AJOL)

    Concerns have also been raised by various researchers about the latent constructs of existing western scales to assess study skills. The objective of this study was to develop, standardize and validate a culturally sensitive study skills questionnaire (SSQ). Methods: a stratified random sample of secondary school students (n ...

  13. Experimental validation of a radio frequency photogun as external electron

    NARCIS (Netherlands)

    Stragier, X.F.D.; Luiten, O.J.; Geer, van der S.B.; Wiel, van der M.J.

    2011-01-01

    A purpose-built RF-photogun as external electron injector for a laser wakefield accelerator has been thoroughly tested. Different properties of the RF-photogun have been measured such as energy, energy spread and transverse emittance. The focus of this study is the investigation of the smallest

  14. CTF Void Drift Validation Study

    Energy Technology Data Exchange (ETDEWEB)

    Salko, Robert K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gosdin, Chris [Pennsylvania State Univ., University Park, PA (United States); Avramova, Maria N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gergar, Marcus [Pennsylvania State Univ., University Park, PA (United States)

    2015-10-26

    This milestone report is a summary of work performed in support of expansion of the validation and verification (V&V) matrix for the thermal-hydraulic subchannel code, CTF. The focus of this study is on validating the void drift modeling capabilities of CTF and verifying the supporting models that impact the void drift phenomenon. CTF uses a simple turbulent-diffusion approximation to model lateral cross-flow due to turbulent mixing and void drift. The void drift component of the model is based on the Lahey and Moody model. The models are a function of two-phase mass, momentum, and energy distribution in the system; therefore, it is necessary to correctly model the ow distribution in rod bundle geometry as a first step to correctly calculating the void distribution due to void drift.

  15. Attainment of Electron Beam Suitable for Medium Energy Electron Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Seletskiy, Sergei M. [Univ. of Rochester, NY (United States)

    2005-01-01

    Electron cooling of charged particle beams is a well-established technique at electron energies of up to 300 keV. However, up to the present time the advance of electron cooling to the MeV-range energies has remained a purely theoretical possibility. The electron cooling project at Fermilab has recently demonstrated the ¯rst cooling of 8.9 GeV/c antiprotons in the Recycler ring, and therefore, has proved the validity of the idea of relativistic electron cool- ing. The Recycler Electron Cooler (REC) is the key component of the Teva- tron Run II luminosity upgrade project. Its performance depends critically on the quality of electron beam. A stable electron beam of 4.3 MeV car- rying 0.5 A of DC current is required. The beam suitable for the Recycler Electron Cooler must have an angular spread not exceeding 200 ¹rad. The full-scale prototype of the REC was designed, built and tested at Fermilab in the Wideband laboratory to study the feasibility of attaining the high-quality electron beam. In this thesis I describe various aspects of development of the Fermilab electron cooling system, and the techniques used to obtain the electron beam suitable for the cooling process. In particular I emphasize those aspects of the work for which I was principally responsible.

  16. Social Studies Oriented Achievement Goal Scale (SOAGS: Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Melehat GEZER

    2016-12-01

    Full Text Available This study aims to develop a valid and reliable instrument for measuring students' social studies achievement goal. The research was conducted on a study group consisted of 374 middle school students studying in the central district of Diyarbakır in 2014-2015 school year fall semester. Expert opinion was consulted with regard to the scale's content and face validity. Exploratory Factor Analysis (EFA and Confirmatory Factor Analysis (CFA were performed in order to measure the scale's construct validity. As a result of EFA, a 29-item and a six-factor structure model which explains 50.82% of the total variance was obtained. The emerging factors were called as a self-approach, task-approach, other-approach, task-avoidance, other-avoidance and self-avoidance respectively. The findings acquired CFA indicated that the 29-item and six-factor structure related to social studies oriented achievement goal scale have acceptable goodness of fit indices. The scale's reliability coefficients were calculated by means of internal consistency method. As a result of reliability analysis, it was determined that the reliability coefficients were within admissible limits. The finding of the item correlation and 27% of upper and lower group comparisons demonstrated that all of the items in the scale should remain. In light of these results, it could be argued that the scale is reliable and valid instrument and can be used in order to test students' social studies achievement goals.

  17. Proteomic signatures of infertile men with clinical varicocele and their validation studies reveal mitochondrial dysfunction leading to infertility

    Directory of Open Access Journals (Sweden)

    Ashok Agarwal

    2016-01-01

    Full Text Available To study the major differences in the distribution of spermatozoa proteins in infertile men with varicocele by comparative proteomics and validation of their level of expression. The study-specific estimates for each varicocele outcome were combined to identify the proteins involved in varicocele-associated infertility in men irrespective of stage and laterality of their clinical varicocele. Expression levels of 5 key proteins (PKAR1A, AK7, CCT6B, HSPA2, and ODF2 involved in stress response and sperm function including molecular chaperones were validated by Western blotting. Ninety-nine proteins were differentially expressed in the varicocele group. Over 87% of the DEP involved in major energy metabolism and key sperm functions were underexpressed in the varicocele group. Key protein functions affected in the varicocele group were spermatogenesis, sperm motility, and mitochondrial dysfunction, which were further validated by Western blotting, corroborating the proteomics analysis. Varicocele is essentially a state of energy deprivation, hypoxia, and hyperthermia due to impaired blood supply, which is corroborated by down-regulation of lipid metabolism, mitochondrial electron transport chain, and Krebs cycle enzymes. To corroborate the proteomic analysis, expression of the 5 identified proteins of interest was validated by Western blotting. This study contributes toward establishing a biomarker "fingerprint" to assess sperm quality on the basis of molecular parameters.

  18. Validity of the use of the neutron-reduction factor in assessing displacement damage to electronics in armoured vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, T.; Jamieson, T.J.

    1990-02-01

    The degree of protection from neutron irradiation afforded to electronics by armoured vehicles is most currently defined by the outside-to-inside ratio of the 1 MeV equivalent neutron fluence for Silicon. It has been proposed that this factor may be approximated by an experimentally measurable parameter - the neutron (tissue kerma) reduction factor. This report examines the validity of this assumption for a variety of realistic nuclear battlefield scenarios, calculated using the computer code VPF2. In addition the response of two neutron dosimeters in the calculated fields is examined.

  19. Simulation Based Studies in Software Engineering: A Matter of Validity

    Directory of Open Access Journals (Sweden)

    Breno Bernard Nicolau de França

    2015-04-01

    Full Text Available Despite the possible lack of validity when compared with other science areas, Simulation-Based Studies (SBS in Software Engineering (SE have supported the achievement of some results in the field. However, as it happens with any other sort of experimental study, it is important to identify and deal with threats to validity aiming at increasing their strength and reinforcing results confidence. OBJECTIVE: To identify potential threats to SBS validity in SE and suggest ways to mitigate them. METHOD: To apply qualitative analysis in a dataset resulted from the aggregation of data from a quasi-systematic literature review combined with ad-hoc surveyed information regarding other science areas. RESULTS: The analysis of data extracted from 15 technical papers allowed the identification and classification of 28 different threats to validity concerned with SBS in SE according Cook and Campbell’s categories. Besides, 12 verification and validation procedures applicable to SBS were also analyzed and organized due to their ability to detect these threats to validity. These results were used to make available an improved set of guidelines regarding the planning and reporting of SBS in SE. CONCLUSIONS: Simulation based studies add different threats to validity when compared with traditional studies. They are not well observed and therefore, it is not easy to identify and mitigate all of them without explicit guidance, as the one depicted in this paper.

  20. Electron-beam lithography

    International Nuclear Information System (INIS)

    Harriott, L.; Liddle, A.

    1997-01-01

    As part of a commemorative series of articles to mark the hundredth anniversary of the discovery of the electron, this article describes the use of electron beams to write features on silicon wafers. Recent advances in electron beam lithography, as it is known, could enable this technology to be used for the mass manufacture of silicon chips. The validation of space-charge optimization and evaluation of printing techniques is underway. (UK)

  1. Efficacy and External Validity of Electronic and Mobile Phone-Based Interventions Promoting Vegetable Intake in Young Adults: A Systematic Review Protocol.

    Science.gov (United States)

    Nour, Monica Marina; Chen, Juliana; Allman-Farinelli, Margaret

    2015-07-28

    Despite social marketing campaigns and behavior change interventions, young adults remain among the lowest consumers of vegetables. The digital era offers potential new avenues for both social marketing and individually tailored programs, through texting, web, and mobile applications. The effectiveness and generalizability of such programs have not been well documented. The aim of this systematic review is to evaluate the efficacy and external validity of social marketing, electronic, and mobile phone-based (mHealth) interventions aimed at increasing vegetable intake in young adults. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) protocol will be used to conduct this systematic review. The search strategy will be executed across eleven electronic databases using combinations of the following search terms: "online intervention", "computer-assisted therapy", "internet", "website", "cell phones", "cyber", "telemedicine", "email", "social marketing", "social media", "mass media", "young adult", and "fruit and vegetables". The reference lists of included studies will also be searched for additional citations. Titles and abstracts will be screened against inclusion criteria and full texts of potentially eligible papers will be assessed by two independent reviewers. Data from eligible papers will be extracted. Quality and risk of bias will be assessed using the Effective Public Health Practice Project (EPHPP) Quality Assessment Tool for Quantitative Studies and The Cochrane Collaboration Risk of Bias assessment tool respectively. The external validity of the studies will be determined based on components such as reach, adoption, and representativeness of participants; intervention implementation and adaption; and program maintenance and institutionalization. Results will be reported quantitatively and qualitatively. Our research is in progress. A draft of the systematic review is currently being produced for publication by the end of 2015

  2. JaCVAM-organized international validation study of the in vivo rodent alkaline comet assay for the detection of genotoxic carcinogens: I. Summary of pre-validation study results.

    Science.gov (United States)

    Uno, Yoshifumi; Kojima, Hajime; Omori, Takashi; Corvi, Raffaella; Honma, Masamistu; Schechtman, Leonard M; Tice, Raymond R; Burlinson, Brian; Escobar, Patricia A; Kraynak, Andrew R; Nakagawa, Yuzuki; Nakajima, Madoka; Pant, Kamala; Asano, Norihide; Lovell, David; Morita, Takeshi; Ohno, Yasuo; Hayashi, Makoto

    2015-07-01

    The in vivo rodent alkaline comet assay (comet assay) is used internationally to investigate the in vivo genotoxic potential of test chemicals. This assay, however, has not previously been formally validated. The Japanese Center for the Validation of Alternative Methods (JaCVAM), with the cooperation of the U.S. NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM)/the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), the European Centre for the Validation of Alternative Methods (ECVAM), and the Japanese Environmental Mutagen Society/Mammalian Mutagenesis Study Group (JEMS/MMS), organized an international validation study to evaluate the reliability and relevance of the assay for identifying genotoxic carcinogens, using liver and stomach as target organs. The ultimate goal of this validation effort was to establish an Organisation for Economic Co-operation and Development (OECD) test guideline. The purpose of the pre-validation studies (i.e., Phase 1 through 3), conducted in four or five laboratories with extensive comet assay experience, was to optimize the protocol to be used during the definitive validation study. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Multiprofissional electronic protocol in ophtalmology with enfasis in strabismus

    OpenAIRE

    RIBEIRO, CHRISTIE GRAF; MOREIRA, ANA TEREZA RAMOS; PINTO, JOSÉ SIMÃO DE PAULA; MALAFAIA, OSVALDO

    2016-01-01

    ABSTRACT Objective: to create and validate an electronic database in ophthalmology focused on strabismus, to computerize this database in the form of a systematic data collection software named Electronic Protocol, and to incorporate this protocol into the Integrated System of Electronic Protocols (SINPE(c)). Methods: this is a descriptive study, with the methodology divided into three phases: (1) development of a theoretical ophthalmologic database with emphasis on strabismus; (2) compute...

  4. Validating Smoking Data From the Veteran’s Affairs Health Factors Dataset, an Electronic Data Source

    Science.gov (United States)

    Brandt, Cynthia A.; Skanderson, Melissa; Justice, Amy C.; Shahrir, Shahida; Butt, Adeel A.; Brown, Sheldon T.; Freiberg, Matthew S.; Gibert, Cynthia L.; Goetz, Matthew Bidwell; Kim, Joon Woo; Pisani, Margaret A.; Rimland, David; Rodriguez-Barradas, Maria C.; Sico, Jason J.; Tindle, Hilary A.; Crothers, Kristina

    2011-01-01

    Introduction: We assessed smoking data from the Veterans Health Administration (VHA) electronic medical record (EMR) Health Factors dataset. Methods: To assess the validity of the EMR Health Factors smoking data, we first created an algorithm to convert text entries into a 3-category smoking variable (never, former, and current). We compared this EMR smoking variable to 2 different sources of patient self-reported smoking survey data: (a) 6,816 HIV-infected and -uninfected participants in the 8-site Veterans Aging Cohort Study (VACS-8) and (b) a subset of 13,689 participants from the national VACS Virtual Cohort (VACS-VC), who also completed the 1999 Large Health Study (LHS) survey. Sensitivity, specificity, and kappa statistics were used to evaluate agreement of EMR Health Factors smoking data with self-report smoking data. Results: For the EMR Health Factors and VACS-8 comparison of current, former, and never smoking categories, the kappa statistic was .66. For EMR Health Factors and VACS-VC/LHS comparison of smoking, the kappa statistic was .61. Conclusions: Based on kappa statistics, agreement between the EMR Health Factors and survey sources is substantial. Identification of current smokers nationally within the VHA can be used in future studies to track smoking status over time, to evaluate smoking interventions, and to adjust for smoking status in research. Our methodology may provide insights for other organizations seeking to use EMR data for accurate determination of smoking status. PMID:21911825

  5. Development of a multi-institutional cohort to facilitate cardiovascular disease biomarker validation using existing biorepository samples linked to electronic health records.

    Science.gov (United States)

    Cross, Deanna S; McCarty, Catherine A; Steinhubl, Steven R; Carey, David J; Erlich, Porat M

    2013-08-01

    Emerging biomarkers for acute myocardial infarction (AMI) may enhance conventional risk-prediction algorithms if they are informative and associated with risk independently of established predictors. In this study, we constructed a cohort for testing emerging biomarkers for AMI in managed-care populations using existing biospecimen repositories linked to electronic health records (EHR). Electronic health record-based biorepositories collected by healthcare systems can be federated to provide large, methodologically sound testing sets for biomarker validation. Subjects ages 40 to 80 years were selected from 2 existing population-based biospecimen repositories. Incident AMI status and covariates were ascertained from the EHR. An ad hoc model for AMI risk was parameterized and validated. Simulation was used to test incremental gains in performance due to the inclusion of biomarkers in this model. Gains in performance were assessed in terms of area under the receiver operating characteristic curve (ROC-AUC) and case reclassification. A total of 18 329 individuals (57% female) contributed 108 400 person-years of EHR follow-up. The crude AMI incidence was 10.8 and 5.0 per 1000 person-years among males and females, respectively. Compared with the model with risk factors alone, inclusion of a simulated biomarker yielded substantial gains in sensitivity without loss of specificity. Furthermore, a net ROC-AUC gain of 13.3% was observed, as well as correct reclassification of 9.8% of incident cases (79 of 806) that were otherwise not considered statin-indicated at baseline under the National Cholesterol Education Program Adult Treatment Panel III criteria. More research is needed to assess incremental contribution of emerging biomarkers for AMI prediction in managed-care populations. © 2013 Wiley Periodicals, Inc.

  6. Electron cloud studies for the LHC and future proton colliders

    CERN Document Server

    Domínguez Sánchez de la Blanca, César Octavio; Zimmermann, Frank

    2014-01-01

    The Large Hadron Collider (LHC) is the world’s largest and most powerful particle collider. Its main objectives are to explore the validity of the standard model of particle physics and to look for new physics beyond it, at unprecedented collision energies and rates. A good luminosity performance is imperative to attain these goals. In the last stage of the LHC commissioning (2011-2012), the limiting factor to achieving the design bunch spacing of 25 ns has been the electron cloud effects. The electron cloud is also expected to be the most important luminosity limitation after the first Long Shut-Down of the LHC (LS1), when the machine should be operated at higher energy and with 25-ns spacing, as well as for the planned luminosity upgrade (HL-LHC) and future high energy proton colliders (HE-LHC and VHE-LHC). This thesis contributes to the understanding of the electron cloud observations during the first run of the LHC (2010-2012), presents the first beam dynamics analysis for the next generation of high en...

  7. ZnO sublimation using a polyenergetic pulsed electron beam source: numerical simulation and validation

    Energy Technology Data Exchange (ETDEWEB)

    Tricot, S; Semmar, N; Lebbah, L; Boulmer-Leborgne, C, E-mail: sylvain.tricot@univ-orleans.f [GREMI, UMR 6606-CNRS/Universite d' Orleans, 14 rue d' Issoudun, BP 6744, 45067 Orleans cedex 2 (France)

    2010-02-17

    This paper details the electro-thermal study of the sublimation phase on a zinc oxide surface. This thermodynamic process occurs when a ZnO target is bombarded by a pulsed electron beam source composed of polyenergetic electrons. The source delivers short pulses of 180 ns of electrons with energies up to 16 keV. The beam total current reaches 800 A and is focused onto a spot area 2 mm in diameter. The Monte Carlo CASINO program is used to study the first stage of the interaction and to define the heat source space distribution inside the ZnO target. Simulation of the second stage of interaction is developed in a COMSOL multiphysics project. The simulated thermal field induced by space and time heat conduction is presented. Typically for a pulsed electron beam 2 mm in diameter of electrons having energies up to 16 keV, the surface temperature reaches a maximum of 7000 K. The calculations are supported by SEM pictures of the target irradiated by various beam energies and numbers of pulses.

  8. ZnO sublimation using a polyenergetic pulsed electron beam source: numerical simulation and validation

    International Nuclear Information System (INIS)

    Tricot, S; Semmar, N; Lebbah, L; Boulmer-Leborgne, C

    2010-01-01

    This paper details the electro-thermal study of the sublimation phase on a zinc oxide surface. This thermodynamic process occurs when a ZnO target is bombarded by a pulsed electron beam source composed of polyenergetic electrons. The source delivers short pulses of 180 ns of electrons with energies up to 16 keV. The beam total current reaches 800 A and is focused onto a spot area 2 mm in diameter. The Monte Carlo CASINO program is used to study the first stage of the interaction and to define the heat source space distribution inside the ZnO target. Simulation of the second stage of interaction is developed in a COMSOL multiphysics project. The simulated thermal field induced by space and time heat conduction is presented. Typically for a pulsed electron beam 2 mm in diameter of electrons having energies up to 16 keV, the surface temperature reaches a maximum of 7000 K. The calculations are supported by SEM pictures of the target irradiated by various beam energies and numbers of pulses.

  9. Electrochemical impedance spectroscopy for study of electronic structure in disordered organic semiconductors—Possibilities and limitations

    Science.gov (United States)

    Schauer, F.; Nádaždy, V.; Gmucová, K.

    2018-04-01

    There is potential in applying conjugated polymers in novel organic optoelectronic devices, where a comprehensive understanding of the fundamental processes and energetics involved during transport and recombination is still lacking, limiting further device optimization. The electronic transport modeling and its optimization need the energy distribution of transport and defect states, expressed by the energy distribution of the Density of States (DOS) function, as input/comparative parameters. We present the Energy Resolved-Electrochemical Impedance Spectroscopy (ER-EIS) method for the study of transport and defect electronic states in organic materials. The method allows mapping over unprecedentedly wide energy and DOS ranges. The ER-EIS spectroscopic method is based on the small signal interaction between the surface of the organic film and the liquid electrolyte containing reduction-oxidation (redox) species, which is similar to the extraction of an electron by an acceptor and capture of an electron by a donor at a semiconductor surface. The desired DOS of electronic transport and defect states can be derived directly from the measured redox response signal to the small voltage perturbation at the instantaneous position of the Fermi energy, given by the externally applied voltage. The theory of the ER-EIS method and conditions for its validity for solid polymers are presented in detail. We choose four case studies on poly(3-hexylthiophene-2,5-diyl) and poly[methyl(phenyl)silane] to show the possibilities of the method to investigate the electronic structure expressed by DOS of polymers with a high resolution of about 6 orders of magnitude and in a wide energy range of 6 eV.

  10. Electron beam lithography

    International Nuclear Information System (INIS)

    Harriott, L.; Liddle, A.

    1997-01-01

    As part of a commemorative series of articles to mark the hundredth anniversary of the discovery of the electron, this article describes the use of electron beams to write features on silicon wafers. Recent advances in electron beam lithography, as it is known, could enable this technology to be used for the mass manufacture of silicon chips. The validation of space-charge optimization and evaluation of printing techniques is underway. 5 figs

  11. Measuring Nutrition Literacy in Spanish-Speaking Latinos: An Exploratory Validation Study.

    Science.gov (United States)

    Gibbs, Heather D; Camargo, Juliana M T B; Owens, Sarah; Gajewski, Byron; Cupertino, Ana Paula

    2017-11-21

    Nutrition is important for preventing and treating chronic diseases highly prevalent among Latinos, yet no tool exists for measuring nutrition literacy among Spanish speakers. This study aimed to adapt the validated Nutrition Literacy Assessment Instrument for Spanish-speaking Latinos. This study was developed in two phases: adaptation and validity testing. Adaptation included translation, expert item content review, and interviews with Spanish speakers. For validity testing, 51 participants completed the Short Assessment of Health Literacy-Spanish (SAHL-S), the Nutrition Literacy Assessment Instrument in Spanish (NLit-S), and socio-demographic questionnaire. Validity and reliability statistics were analyzed. Content validity was confirmed with a Scale Content Validity Index of 0.96. Validity testing demonstrated NLit-S scores were strongly correlated with SAHL-S scores (r = 0.52, p internal consistency was excellent (Cronbach's α = 0.92). The NLit-S demonstrates validity and reliability for measuring nutrition literacy among Spanish-speakers.

  12. California Diploma Project Technical Report III: Validity Study--Validity Study of the Health Sciences and Medical Technology Standards

    Science.gov (United States)

    McGaughy, Charis; Bryck, Rick; de Gonzalez, Alicia

    2012-01-01

    This study is a validity study of the recently revised version of the Health Science Standards. The purpose of this study is to understand how the Health Science Standards relate to college and career readiness, as represented by survey ratings submitted by entry-level college instructors of health science courses and industry representatives. For…

  13. Study of electron transmission through thin metallic films by the electron moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Babikova, Yu.F.; Vakar, O.M.; Gruzin, O.M.; Petrikin, Yu.V.

    1983-01-01

    Results of the experimental study of the transmission of conversion electrons through aluminium, iron, tin and gold films are presented. Absorption of resonance electrons of the Moessbauer nuclide 57 Fe, formed during target irradiation with γ-quanta of 57 Co source in chromium matrix has been studied. It is asserted that absorption of conversion electrons in films of different elements is similar; at that, like in the case of β-particles, the law of absorption of resonance electrons, emitted from the flat layer, is exponential For conversion electrons of the Moessbauer nuclide 57 Fe the absorption coefficient is (0.025+-0.002) cm 2 /μg, which in the case of iron absorbing film corresponds to (20.0+-1.0)x10 4 cm -1

  14. Measurements of sin2 θ/sub w/ from studies of the elastic scattering of neutrinos by protons and electrons

    International Nuclear Information System (INIS)

    Mann, A.K.

    1986-01-01

    This talk is intended as a brief report on studies of the elastic scattering of neutrinos by protons and electrons. Measurements of the ratios of muon antineutrino and muon neutrino elastic scattering on protons, and the corresponding ratio for elastic scattering on electrons minimize systematic experimental errors, and lead directly to values of the fundamental parameter of the electroweak interaction, the Weinberg Angle, with minimal ambiguity. Accordingly, the principal motivation in carrying out these studies was the desire to obtain and compare precise values of the Weinberg Angle from both the semileptonic and leptonic reactions as still another test of the basic validity of the standard electroweak theory. 10 refs., 11 figs

  15. Studies of electron drift velocity in nitrogen and isobutane

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Pontificia Univ. Catolica de Sao Paulo (PUC/SP), SP (Brazil); Vivaldini, Tulio C.; Lima, Iara B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ridenti, Marco A.; Pascholati, Paulo R. [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Fisica. Lab. do Acelerador Linear; Fonte, Paulo; Mangiarotti, Alessio [Universidade de Coimbra (Portugal). Dept. de fisica. Lab. de Instrumentacao e Fisica Experimental de Particulas

    2009-07-01

    Full text: The electron drift velocity is one of the most important transport parameters used to describe the physical behaviour of gas discharges and the development of avalanches in gaseous detectors, mainly when temporal information is significant, as in drift chambers and in the recent Resistive Plate Chambers (RPCs). Although many filling gases, isobutane is frequently used in RPCs, due to its excellent timing properties, but at high electric fields conditions there are insufficient data available in literature. In the present work we report the preliminary results related to the dependence of the electron drift velocity for isobutane as function of the reduced electric field E/N, in the range of 100 Td up to 216 Td. There are different methods to determine electron drift velocity in a gas, and our measurements were based on the Pulsed Townsend technique, which consists of extracting electrons from a metallic cathode and accelerates them toward the anode by a uniform electric field. Once the drift distance and the transit time are known, the drift velocities can be determined. In our system, the incidence of a nitrogen laser beam (LTB MNL200-LD) liberates electron from the cathode made of aluminium (40mm diameter). By means of a high voltage supply (Bertan, 225-30), these electrons are accelerated toward the anode (made of a high resistivity glass - 2:10{sup 12}{omega} cm) and this movement produces a fast electric signal in the anode, which is digitalized in an oscilloscope (LeCroy WavePro 7000) with 1 GHz bandwidth and 10 GS/s. The values obtained were compared to that ones of a Bolsig+ simulation code. In order to validate the technique and to analyze non-uniformity effects, results for nitrogen are also presented. (author)

  16. Studies of electron drift velocity in nitrogen and isobutane

    International Nuclear Information System (INIS)

    Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B.; Vivaldini, Tulio C.; Lima, Iara B.; Ridenti, Marco A.; Pascholati, Paulo R.; Fonte, Paulo; Mangiarotti, Alessio

    2009-01-01

    Full text: The electron drift velocity is one of the most important transport parameters used to describe the physical behaviour of gas discharges and the development of avalanches in gaseous detectors, mainly when temporal information is significant, as in drift chambers and in the recent Resistive Plate Chambers (RPCs). Although many filling gases, isobutane is frequently used in RPCs, due to its excellent timing properties, but at high electric fields conditions there are insufficient data available in literature. In the present work we report the preliminary results related to the dependence of the electron drift velocity for isobutane as function of the reduced electric field E/N, in the range of 100 Td up to 216 Td. There are different methods to determine electron drift velocity in a gas, and our measurements were based on the Pulsed Townsend technique, which consists of extracting electrons from a metallic cathode and accelerates them toward the anode by a uniform electric field. Once the drift distance and the transit time are known, the drift velocities can be determined. In our system, the incidence of a nitrogen laser beam (LTB MNL200-LD) liberates electron from the cathode made of aluminium (40mm diameter). By means of a high voltage supply (Bertan, 225-30), these electrons are accelerated toward the anode (made of a high resistivity glass - 2:10 12 Ω cm) and this movement produces a fast electric signal in the anode, which is digitalized in an oscilloscope (LeCroy WavePro 7000) with 1 GHz bandwidth and 10 GS/s. The values obtained were compared to that ones of a Bolsig+ simulation code. In order to validate the technique and to analyze non-uniformity effects, results for nitrogen are also presented. (author)

  17. Delivery of modulated electron beams with conventional photon multi-leaf collimators

    International Nuclear Information System (INIS)

    Klein, Eric E; Mamalui-Hunter, Maria; Low, Daniel A

    2009-01-01

    Electron beam radiotherapy is an accepted method to treat shallow tumors. However, modulation of electrons to customize dose distributions has not readily been achieved. Studies of bolus and tertiary collimation systems have been met with limitations. We pursue the use of photon multi-leaf collimators (MLC) for modulated electron radiotherapy (MERT) to achieve customized distributions for potential clinical use. As commercial planning systems do not support the use of MLC with electrons, planning was conducted using Monte Carlo calculations. Segmented and dynamic modulated delivery of multiple electron segments was configured, calculated and delivered for validation. Delivery of electrons with segmented or dynamic leaf motion was conducted. A phantom possessing an idealized stepped target was planned and optimized with subsequent validation by measurements. Finally, clinical treatment plans were conducted for post-mastectomy and cutaneous lymphoma of the scalp using forward optimization techniques. Comparison of calculations and measurements was successful with agreement of ±2%/2 mm for the energies, segment sizes, depths tested for delivered segments for the dynamic and segmented delivery. Clinical treatment plans performed provided optimal dose coverage of the target while sparing distal organs at risk. Execution of plans using an anthropomorphic phantom to ensure safe and efficient delivery was conducted. Our study validates that MERT is not only possible using the photon MLC, but the efficient and safe delivery inherent with the dynamic delivery provides an ideal technique for shallow tumor treatment.

  18. New pediatric vision screener, part II: electronics, software, signal processing and validation.

    Science.gov (United States)

    Gramatikov, Boris I; Irsch, Kristina; Wu, Yi-Kai; Guyton, David L

    2016-02-04

    We have developed an improved pediatric vision screener (PVS) that can reliably detect central fixation, eye alignment and focus. The instrument identifies risk factors for amblyopia, namely eye misalignment and defocus. The device uses the birefringence of the human fovea (the most sensitive part of the retina). The optics have been reported in more detail previously. The present article focuses on the electronics and the analysis algorithms used. The objective of this study was to optimize the analog design, data acquisition, noise suppression techniques, the classification algorithms and the decision making thresholds, as well as to validate the performance of the research instrument on an initial group of young test subjects-18 patients with known vision abnormalities (eight male and 10 female), ages 4-25 (only one above 18) and 19 controls with proven lack of vision issues. Four statistical methods were used to derive decision making thresholds that would best separate patients with abnormalities from controls. Sensitivity and specificity were calculated for each method, and the most suitable one was selected. Both the central fixation and the focus detection criteria worked robustly and allowed reliable separation between normal test subjects and symptomatic subjects. The sensitivity of the instrument was 100 % for both central fixation and focus detection. The specificity was 100 % for central fixation and 89.5 % for focus detection. The overall sensitivity was 100 % and the overall specificity was 94.7 %. Despite the relatively small initial sample size, we believe that the PVS instrument design, the analysis methods employed, and the device as a whole, will prove valuable for mass screening of children.

  19. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  20. Cyber Victim and Bullying Scale: A Study of Validity and Reliability

    Science.gov (United States)

    Cetin, Bayram; Yaman, Erkan; Peker, Adem

    2011-01-01

    The purpose of this study is to develop a reliable and valid scale, which determines cyber victimization and bullying behaviors of high school students. Research group consisted of 404 students (250 male, 154 male) in Sakarya, in 2009-2010 academic years. In the study sample, mean age is 16.68. Content validity and face validity of the scale was…

  1. Status of the physics validation studies using Geant4 in ATLAS

    CERN Document Server

    AUTHOR|(CDS)2108477

    2003-01-01

    The new simulation for the ATLAS detector at LHC is performed using Geant4 in a complete OO/C++ environment. In this framework the simulation of the various test beams for the different ATLAS subdetectors offers an excellent opportunity to perform physics validation studies over a wide range of physics domains: the electromagnetic processes, the individual hadronic interactions, the electromagnetic and hadronic signals in calorimeters. The simulation is implemented by paying special attention to all details of the experimental layout and by testing all possible physics processes which may be of relevance to the specific detector under test: the resulting simulation programs are often more detailed than the corresponding Geant3-based simulation suites. In this paper we present relevant features of muon, electron and pion signals in various ATLAS detectors. All remaining discrepancies between Geant4 and test-beam data are currently being addressed and progress is continuous. This work shows that Geant4 is becom...

  2. Electronic Publishing or Electronic Information Handling?

    Science.gov (United States)

    Heck, A.

    The current dramatic evolution in information technology is bringing major modifications in the way scientists communicate. The concept of 'electronic publishing' is too restrictive and has often different, sometimes conflicting, interpretations. It is thus giving way to the broader notion of 'electronic information handling' encompassing the diverse types of information, the different media, as well as the various communication methodologies and technologies. New problems and challenges result also from this new information culture, especially on legal, ethical, and educational grounds. The procedures for validating 'published material' and for evaluating scientific activities will have to be adjusted too. 'Fluid' information is becoming a common concept. Electronic publishing cannot be conceived without link to knowledge bases nor without intelligent information retrieval tools.

  3. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  4. Cooperative learning benefits scale: construction and validation studies

    Directory of Open Access Journals (Sweden)

    José Lopes

    2014-07-01

    Full Text Available The aim of this study was to develop and validate a scale of benefits of the Cooperative Learning (SBCL given the exiguity of instruments that evaluate these outputs of the method. The study resorted to a convenience sample comprised of 162 students, males and females, aged between 11 and 18 years. The final instrument has 23 items in a two-dimensional factor structure: psychological and academic benefits and social benefits. The results indicate that the SBCL present good psychometric properties (construct and discriminant validity and reliability. The results are discussed in light of the model of cooperative learning.

  5. Development and validation of an automated delirium risk assessment system (Auto-DelRAS) implemented in the electronic health record system.

    Science.gov (United States)

    Moon, Kyoung-Ja; Jin, Yinji; Jin, Taixian; Lee, Sun-Mi

    2018-01-01

    A key component of the delirium management is prevention and early detection. To develop an automated delirium risk assessment system (Auto-DelRAS) that automatically alerts health care providers of an intensive care unit (ICU) patient's delirium risk based only on data collected in an electronic health record (EHR) system, and to evaluate the clinical validity of this system. Cohort and system development designs were used. Medical and surgical ICUs in two university hospitals in Seoul, Korea. A total of 3284 patients for the development of Auto-DelRAS, 325 for external validation, 694 for validation after clinical applications. The 4211 data items were extracted from the EHR system and delirium was measured using CAM-ICU (Confusion Assessment Method for Intensive Care Unit). The potential predictors were selected and a logistic regression model was established to create a delirium risk scoring algorithm to construct the Auto-DelRAS. The Auto-DelRAS was evaluated at three months and one year after its application to clinical practice to establish the predictive validity of the system. Eleven predictors were finally included in the logistic regression model. The results of the Auto-DelRAS risk assessment were shown as high/moderate/low risk on a Kardex screen. The predictive validity, analyzed after the clinical application of Auto-DelRAS after one year, showed a sensitivity of 0.88, specificity of 0.72, positive predictive value of 0.53, negative predictive value of 0.94, and a Youden index of 0.59. A relatively high level of predictive validity was maintained with the Auto-DelRAS system, even one year after it was applied to clinical practice. Copyright © 2017. Published by Elsevier Ltd.

  6. BIOMOVS: an international model validation study

    International Nuclear Information System (INIS)

    Haegg, C.; Johansson, G.

    1988-01-01

    BIOMOVS (BIOspheric MOdel Validation Study) is an international study where models used for describing the distribution of radioactive and nonradioactive trace substances in terrestrial and aquatic environments are compared and tested. The main objectives of the study are to compare and test the accuracy of predictions between such models, explain differences in these predictions, recommend priorities for future research concerning the improvement of the accuracy of model predictions and act as a forum for the exchange of ideas, experience and information. (author)

  7. BIOMOVS: An international model validation study

    International Nuclear Information System (INIS)

    Haegg, C.; Johansson, G.

    1987-01-01

    BIOMOVS (BIOspheric MOdel Validation Study) is an international study where models used for describing the distribution of radioactive and nonradioactive trace substances in terrestrial and aquatic environments are compared and tested. The main objectives of the study are to compare and test the accuracy of predictions between such models, explain differences in these predictions, recommend priorities for future research concerning the improvement of the accuracy of model predictions and act as a forum for the exchange of ideas, experience and information. (orig.)

  8. Elaboration and Validation of the Medication Prescription Safety Checklist 1

    Science.gov (United States)

    Pires, Aline de Oliveira Meireles; Ferreira, Maria Beatriz Guimarães; do Nascimento, Kleiton Gonçalves; Felix, Márcia Marques dos Santos; Pires, Patrícia da Silva; Barbosa, Maria Helena

    2017-01-01

    ABSTRACT Objective: to elaborate and validate a checklist to identify compliance with the recommendations for the structure of medication prescriptions, based on the Protocol of the Ministry of Health and the Brazilian Health Surveillance Agency. Method: methodological research, conducted through the validation and reliability analysis process, using a sample of 27 electronic prescriptions. Results: the analyses confirmed the content validity and reliability of the tool. The content validity, obtained by expert assessment, was considered satisfactory as it covered items that represent the compliance with the recommendations regarding the structure of the medication prescriptions. The reliability, assessed through interrater agreement, was excellent (ICC=1.00) and showed perfect agreement (K=1.00). Conclusion: the Medication Prescription Safety Checklist showed to be a valid and reliable tool for the group studied. We hope that this study can contribute to the prevention of adverse events, as well as to the improvement of care quality and safety in medication use. PMID:28793128

  9. External validity of post-stroke interventional gait rehabilitation studies.

    Science.gov (United States)

    Kafri, Michal; Dickstein, Ruth

    2017-01-01

    Gait rehabilitation is a major component of stroke rehabilitation, and is supported by extensive research. The objective of this review was to examine the external validity of intervention studies aimed at improving gait in individuals post-stroke. To that end, two aspects of these studies were assessed: subjects' exclusion criteria and the ecological validity of the intervention, as manifested by the intervention's technological complexity and delivery setting. Additionally, we examined whether the target population as inferred from the titles/abstracts is broader than the population actually represented by the reported samples. We systematically researched PubMed for intervention studies to improve gait post-stroke, working backwards from the beginning of 2014. Exclusion criteria, the technological complexity of the intervention (defined as either elaborate or simple), setting, and description of the target population in the titles/abstracts were recorded. Fifty-two studies were reviewed. The samples were exclusive, with recurrent stroke, co-morbidities, cognitive status, walking level, and residency being major reasons for exclusion. In one half of the studies, the intervention was elaborate. Descriptions of participants in the title/abstract in almost one half of the studies included only the diagnosis (stroke or comparable terms) and its stage (acute, subacute, and chronic). The external validity of a substantial number of intervention studies about rehabilitation of gait post-stroke appears to be limited by exclusivity of the samples as well as by deficiencies in ecological validity of the interventions. These limitations are not accurately reflected in the titles or abstracts of the studies.

  10. Method validation for chemical composition determination by electron microprobe with wavelength dispersive spectrometer

    Science.gov (United States)

    Herrera-Basurto, R.; Mercader-Trejo, F.; Muñoz-Madrigal, N.; Juárez-García, J. M.; Rodriguez-López, A.; Manzano-Ramírez, A.

    2016-07-01

    The main goal of method validation is to demonstrate that the method is suitable for its intended purpose. One of the advantages of analytical method validation is translated into a level of confidence about the measurement results reported to satisfy a specific objective. Elemental composition determination by wavelength dispersive spectrometer (WDS) microanalysis has been used over extremely wide areas, mainly in the field of materials science, impurity determinations in geological, biological and food samples. However, little information is reported about the validation of the applied methods. Herein, results of the in-house method validation for elemental composition determination by WDS are shown. SRM 482, a binary alloy Cu-Au of different compositions, was used during the validation protocol following the recommendations for method validation proposed by Eurachem. This paper can be taken as a reference for the evaluation of the validation parameters more frequently requested to get the accreditation under the requirements of the ISO/IEC 17025 standard: selectivity, limit of detection, linear interval, sensitivity, precision, trueness and uncertainty. A model for uncertainty estimation was proposed including systematic and random errors. In addition, parameters evaluated during the validation process were also considered as part of the uncertainty model.

  11. Study of electron-vibrational interaction in 5d states of Ce{sup 3+} ions in the chloroapatite system

    Energy Technology Data Exchange (ETDEWEB)

    Bhoyar, Priyanka D. [Department of Physics, R.T.M. Nagpur University, Nagpur, 440033 (India); Brik, M.G., E-mail: brik@ut.ee [College of Sciences, Chongqing University of Posts and Telecommunications, Chongqing, 400065 (China); Institute of Physics, University of Tartu, Ravila 14C, Tartu, 50411 (Estonia); Institute of Physics, Polish Academy of Sciences, al. Lotnikow 32/46, 02-668, Warsaw (Poland); Institute of Physics, Jan Dlugosz University, Armii Krajowej 13/15, PL-42200, Czestochowa (Poland); Dhoble, S.J., E-mail: sjdhoble@rediffmail.com [Department of Physics, R.T.M. Nagpur University, Nagpur, 440033 (India)

    2016-08-15

    Electron-vibrational interaction (EVI) in interconfigurational 5d-4f transition of Ce{sup 3+}-doped alkaline-earth chlorophosphates, also known as apatites, is studied for the first time in this work. Using the configurational coordinate model, the main EVI parameters such as Huang-Rhys factor, effective phonon energy and the zero-phonon line (ZPL) position are determined for all samples studied. Photoluminescence characteristics of these compounds are utilized to estimate EVI parameters. As a reliable test validating the obtained results, the emission band shape of was modeled to yield good agreement with experimental emission spectra. The values of EVI parameters were systematically compared for all studied materials as well as with similar systems with halide ions. - Highlights: • EVI in Ce{sup 3+}-doped alkaline-earth halochlorophosphates is studied for the first time in this work. • The EVI parameters are estimated using the configurational coordinate model. • Estimated EVI parameters are validated by modeling emission spectra. • Parameters are systematically compared.

  12. Transmission electron microscope studies of extraterrestrial materials

    Science.gov (United States)

    Keller, Lindsay P.

    1995-01-01

    Transmission Electron Microscopy, X-Ray spectrometry and electron-energy-loss spectroscopy are used to analyse carbon in interplanetary dust particles. Optical micrographs are shown depicting cross sections of the dust particles embedded in sulphur. Selected-area electron diffraction patterns are shown. Transmission Electron Microscope specimens of lunar soil were prepared using two methods: ion-milling and ultramicrotomy. A combination of high resolution TEM imaging and electron diffraction is used to characterize the opaque assemblages. The opaque assemblages analyzed in this study are dominated by ilmenite with lesser rutile and spinel exsolutions, and traces of Fe metal.

  13. A Study on Guide Sign Validity in Driving Simulator

    Directory of Open Access Journals (Sweden)

    Wei Zhonghua

    2011-12-01

    Full Text Available The role of guide sign to inform road user about the information of network is important. How to design and locate guide sign to increase traffic operation efficiency is a key point for traffic engineers. Driving simulator is useful devised to study guide sign in the process and system control. For the purpose of studying guide signs using the tool of driving simulator, guide sign's validity in driving simulator was studied. Results of this experiment are the foundation of further study on guide sign. Simulator calibration procedure for guide sign was set up in this study. Legibility distance as measure of performance was used to evaluate the validity of guide sign in driving simulator. Thirty two participants were recruited. Results indicated legibility distance and speed were inversely related with the method of data mining. Legibility distance and text height of guide sign were positive related. When speed is 20km/h, 30km/h, 40km/h, magnifying power of text height is 4.3, 4.1, 3.8, while guide signs are absolute validity in driving simulator.

  14. Validation of an Improved Computer-Assisted Technique for Mining Free-Text Electronic Medical Records.

    Science.gov (United States)

    Duz, Marco; Marshall, John F; Parkin, Tim

    2017-06-29

    The use of electronic medical records (EMRs) offers opportunity for clinical epidemiological research. With large EMR databases, automated analysis processes are necessary but require thorough validation before they can be routinely used. The aim of this study was to validate a computer-assisted technique using commercially available content analysis software (SimStat-WordStat v.6 (SS/WS), Provalis Research) for mining free-text EMRs. The dataset used for the validation process included life-long EMRs from 335 patients (17,563 rows of data), selected at random from a larger dataset (141,543 patients, ~2.6 million rows of data) and obtained from 10 equine veterinary practices in the United Kingdom. The ability of the computer-assisted technique to detect rows of data (cases) of colic, renal failure, right dorsal colitis, and non-steroidal anti-inflammatory drug (NSAID) use in the population was compared with manual classification. The first step of the computer-assisted analysis process was the definition of inclusion dictionaries to identify cases, including terms identifying a condition of interest. Words in inclusion dictionaries were selected from the list of all words in the dataset obtained in SS/WS. The second step consisted of defining an exclusion dictionary, including combinations of words to remove cases erroneously classified by the inclusion dictionary alone. The third step was the definition of a reinclusion dictionary to reinclude cases that had been erroneously classified by the exclusion dictionary. Finally, cases obtained by the exclusion dictionary were removed from cases obtained by the inclusion dictionary, and cases from the reinclusion dictionary were subsequently reincluded using Rv3.0.2 (R Foundation for Statistical Computing, Vienna, Austria). Manual analysis was performed as a separate process by a single experienced clinician reading through the dataset once and classifying each row of data based on the interpretation of the free

  15. Electronic Elections

    DEFF Research Database (Denmark)

    Schürmann, Carsten

    2009-01-01

    Electronic voting technology is a two edged sword. It comes with many risks but brings also many benefits. Instead of flat out rejecting the technology as uncontrollably dangerous, we advocate in this paper a different technological angle that renders electronic elections trustworthy beyond...... the usual levels of doubt. We exploit the trust that voters currently have into the democratic process and model our techniques around that observation accordingly. In particular, we propose a technique of trace emitting computations to record the individual steps of an electronic voting machine...... for a posteriori validation on an acceptably small trusted computing base. Our technology enables us to prove that an electronic elections preserves the voter’s intent, assuming that the voting machine and the trace verifier are independent....

  16. Early childhood electronic media use as a predictor of poorer well-being: a prospective cohort study.

    Science.gov (United States)

    Hinkley, Trina; Verbestel, Vera; Ahrens, Wolfgang; Lissner, Lauren; Molnár, Dénes; Moreno, Luis A; Pigeot, Iris; Pohlabeln, Hermann; Reisch, Lucia A; Russo, Paola; Veidebaum, Toomas; Tornaritis, Michael; Williams, Garrath; De Henauw, Stefaan; De Bourdeaudhuij, Ilse

    2014-05-01

    Identifying associations between preschool-aged children's electronic media use and their later well-being is essential to supporting positive long-term outcomes. To investigate possible dose-response associations of young children's electronic media use with their later well-being. The IDEFICS (Identification and Prevention of Dietary- and Lifestyle-Induced Health Effects in Children and Infants) study is a prospective cohort study with an intervention component. Data were collected at baseline from September 1, 2007, through June 30, 2008, and at follow-up from September 1, 2009, through May 31, 2010, in 8 European countries participating in the IDEFICS study. This investigation is based on 3604 children aged 2 to 6 years who participated in the longitudinal component of the IDEFICS study only and not in the intervention. Early childhood electronic media use. The following 6 indicators of well-being from 2 validated instruments were used as outcomes at follow-up: Peer problems and Emotional problems subscales from the Strengths and Difficulties Questionnaire and Emotional well-being, Self-esteem, Family functioning, and Social networks subscales from the KINDLR (Questionnaire for Measuring Health-Related Quality of Life in Children and Adolescents-Revised Version). Each scale was dichotomized to identify those children at risk for poorer outcomes. Indicators of electronic media use (weekday and weekend television and electronic game [e-game]/computer use) from baseline were used as predictors. Associations varied between boys and girls; however, associations suggested that increased levels of electronic media use predicted poorer well-being outcomes. Television viewing on weekdays or weekends was more consistently associated with poorer outcomes than e-game/computer use. Across associations, the likelihood of adverse outcomes in children ranged from a 1.2- to 2.0-fold increase for emotional problems and poorer family functioning for each additional hour of

  17. Distress Tolerance Scale: A Study of Reliability and Validity

    Directory of Open Access Journals (Sweden)

    Ahmet Emre SARGIN

    2012-11-01

    Full Text Available Objective: Distress Tolerance Scale (DTS is developed by Simons and Gaher in order to measure individual differences in the capacity of distress tolerance.The aim of this study is to assess the reliability and validity of the Turkish version of DTS. Method: One hundred and sixty seven university students (male=66, female=101 participated in this study. Beck Anxiety Inventory (BAI, State-trait Anxiety Inventory (STAI and Discomfort Intolerance Scale (DIS were used to determine the criterion validity. Construct validity was evaluated with factor analysis after the Kaiser-Meyer-Olkin (KMO and Barlett test had been performed. To assess the test-retest reliability, the scale was re-applied to 79 participants six weeks later. Results: To assess construct validity, factor analyses were performed using varimax principal components analysis with varimax rotation. While there were factors in the original study, our factor analysis resulted in three factors. Cronbach’s alpha coefficients for the entire scale and tolerance, regulation, self-efficacy subscales were .89, .90, .80 and .64 respectively. There were correlations at the level of 0.01 between the Trait Anxiety Inventory of STAI and BAI, and all the subscales of DTS and also between the State Anxiety Inventory and regulation subscale. Both of the subscales of DIS were correlated with the entire subscale and all the subscales except regulation at the level of 0.05.Test-retest reliability was statistically significant at the level of 0.01. Conclusion: Analysis demonstrated that DTS had a satisfactory level of reliability and validity in Turkish university students.

  18. 40 CFR 152.93 - Citation of a previously submitted valid study.

    Science.gov (United States)

    2010-07-01

    ... Data Submitters' Rights § 152.93 Citation of a previously submitted valid study. An applicant may demonstrate compliance for a data requirement by citing a valid study previously submitted to the Agency. The... the original data submitter, the applicant may cite the study only in accordance with paragraphs (b...

  19. Turkish Version of Kolcaba's Immobilization Comfort Questionnaire: A Validity and Reliability Study.

    Science.gov (United States)

    Tosun, Betül; Aslan, Özlem; Tunay, Servet; Akyüz, Aygül; Özkan, Hüseyin; Bek, Doğan; Açıksöz, Semra

    2015-12-01

    The purpose of this study was to determine the validity and reliability of the Turkish version of the Immobilization Comfort Questionnaire (ICQ). The sample used in this methodological study consisted of 121 patients undergoing lower extremity arthroscopy in a training and research hospital. The validity study of the questionnaire assessed language validity, structural validity and criterion validity. Structural validity was evaluated via exploratory factor analysis. Criterion validity was evaluated by assessing the correlation between the visual analog scale (VAS) scores (i.e., the comfort and pain VAS scores) and the ICQ scores using Spearman's correlation test. The Kaiser-Meyer-Olkin coefficient and Bartlett's test of sphericity were used to determine the suitability of the data for factor analysis. Internal consistency was evaluated to determine reliability. The data were analyzed with SPSS version 15.00 for Windows. Descriptive statistics were presented as frequencies, percentages, means and standard deviations. A p value ≤ .05 was considered statistically significant. A moderate positive correlation was found between the ICQ scores and the VAS comfort scores; a moderate negative correlation was found between the ICQ and the VAS pain measures in the criterion validity analysis. Cronbach α values of .75 and .82 were found for the first and second measurements, respectively. The findings of this study reveal that the ICQ is a valid and reliable tool for assessing the comfort of patients in Turkey who are immobilized because of lower extremity orthopedic problems. Copyright © 2015. Published by Elsevier B.V.

  20. Multidimensional measures validated for home health needs of older persons: A systematic review.

    Science.gov (United States)

    de Rossi Figueiredo, Daniela; Paes, Lucilene Gama; Warmling, Alessandra Martins; Erdmann, Alacoque Lorenzini; de Mello, Ana Lúcia Schaefer Ferreira

    2018-01-01

    To conduct a systematic review of the literature on valid and reliable multidimensional instruments to assess home health needs of older persons. Systematic review. Electronic databases, PubMed/Medline, Web of Science, Scopus, Cumulative Index to Nursing and Allied Health Literature, Scientific Electronic Library Online and the Latin American and Caribbean Health Sciences Information. All English, Portuguese and Spanish literature which included studies of reliability and validity of instruments that assessed at least two dimensions: physical, psychological, social support and functional independence, self-rated health behaviors and contextual environment and if such instruments proposed interventions after evaluation and/or monitoring changes over a period of time. Older persons aged 60 years or older. Of the 2397 studies identified, 32 were considered eligible. Two-thirds of the instruments proposed the physical, psychological, social support and functional independence dimensions. Inter-observer and intra-observer reliability and internal consistency values were 0.7 or above. More than two-thirds of the studies included validity (n=26) and more than one validity was tested in 15% (n=4) of these. Only 7% (n=2) proposed interventions after evaluation and/or monitoring changes over a period of time. Although the multidimensional assessment was performed, and the reliability values of the reviewed studies were satisfactory, different validity tests were not present in several studies. A gap at the instrument conception was observed related to interventions after evaluation and/or monitoring changes over a period of time. Further studies with this purpose are necessary for home health needs of the older persons. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Studies of electron cyclotron emission on text

    International Nuclear Information System (INIS)

    Gandy, R.F.

    1990-07-01

    The Auburn University electron cyclotron emission (ECE) system has made many significant contributions to the TEXT experimental program during the past five years. Contributions include electron temperature information used in the following areas of study: electron cyclotron heating (ECH), pellet injection, and impurity/energy transport. Details of the role which the Auburn ECE system has played will now be discussed

  2. Dissociative electron attachment studies on acetone

    International Nuclear Information System (INIS)

    Prabhudesai, Vaibhav S.; Tadsare, Vishvesh; Ghosh, Sanat; Gope, Krishnendu; Davis, Daly; Krishnakumar, E.

    2014-01-01

    Dissociative electron attachment (DEA) to acetone is studied in terms of the absolute cross section for various fragment channels in the electron energy range of 0–20 eV. H − is found to be the most dominant fragment followed by O − and OH − with only one resonance peak between 8 and 9 eV. The DEA dynamics is studied by measuring the angular distribution and kinetic energy distribution of fragment anions using Velocity Slice Imaging technique. The kinetic energy and angular distribution of H − and O − fragments suggest a many body break-up for the lone resonance observed. The ab initio calculations show that electron is captured in the multi-centered anti-bonding molecular orbital which would lead to a many body break-up of the resonance

  3. Development and Validation of an ICP-MS Method for Simultaneous Determination of Selected Metals in Electronic Cigarette Aerosol

    Directory of Open Access Journals (Sweden)

    Ohashi Shintaro

    2018-04-01

    Full Text Available Safety and quality standards for electronic cigarettes (e-cigarettes have been introduced regionally. In 2016, the U.S. Food and Drug Administration (FDA issued a rule to regulate e-cigarettes, requiring to report harmful and potentially harmful constituents (HPHCs. In the United Kingdom, the British Standards Institution (BSI specified the metals to be monitored for e-cigarettes. In this study, a method was developed and validated for the simultaneous determination of 13 metals (Be, Al, Cr, Fe, Co, Ni, Cu, As, Se, Ag, Cd, Sn and Pb in e-cigarette aerosol. Furthermore, matrix effects of major constituents in the aerosol were investigated using glycerol or 1,2-propylene glycol solutions. E-cigarette aerosol was generated by a rotary smoking machine according to CORESTA Recommended Method N° 81 and collected by an electrostatic precipitator coupled to an impinger containing nitric acid. The collected aerosol was dissolved in nitric acid and an aliquot of this solution was analyzed by inductively coupled plasma mass spectrometry (ICP-MS equipped with a collision/reaction cell.

  4. Validation of a zero-dimensional model for prediction of NOx and engine performance for electronically controlled marine two-stroke diesel engines

    International Nuclear Information System (INIS)

    Scappin, Fabio; Stefansson, Sigurður H.; Haglind, Fredrik; Andreasen, Anders; Larsen, Ulrik

    2012-01-01

    The aim of this paper is to derive a methodology suitable for energy system analysis for predicting the performance and NO x emissions of marine low speed diesel engines. The paper describes a zero-dimensional model, evaluating the engine performance by means of an energy balance and a two zone combustion model using ideal gas law equations over a complete crank cycle. The combustion process is divided into intervals, and the product composition and flame temperature are calculated in each interval. The NO x emissions are predicted using the extended Zeldovich mechanism. The model is validated using experimental data from two MAN B and W engines; one case being data subject to engine parameter changes corresponding to simulating an electronically controlled engine; the second case providing data covering almost all model input and output parameters. The first case of validation suggests that the model can predict specific fuel oil consumption and NO x emissions within the 95% confidence intervals given by the experimental measurements. The second validation confirms the capability of the model to match measured engine output parameters based on measured engine input parameters with a maximum 5% deviation. - Highlights: ► A fast realistic model of a marine two-stroke low speed diesel engine was derived. ► The model is fast and accurate enough for future complex energy systems analysis. ► The effects of engine tuning were validated with experimental tests. ► The model was validated while constrained by experimental input and output data.

  5. Some recent studies of electron swarms in gases

    International Nuclear Information System (INIS)

    Tagashira, H.

    1992-01-01

    Some recent studies of electron swarms in gases under the action of an electric field are introduced. The studies include a new type of continuity equation for electrons having a form in which the partial derivative of the electron density with respect to position and to time are interchanged, a method to deduce the time-of-flight and arrival-time-spectrum swarm parameters based on a Fourier-transformed Boltzmann equation, an examination of the correspondence between experimental and theoretical electron drift velocities, and an automatic technique to deduce the electron-gas molecule collision cross section from electron drift velocity data. A method for the deduction of electron collision cross sections with gas molecules having vibrational excitation cross sections greater than the elastic momentum transfer cross section by using a gas mixture technique, an integral type of method for solution of the Boltzmann equation with salient numerical stability, a quantitative analysis of the effect of Penning ionisation, and the behaviour of electron swarms under radio frequency electric fields, are also briefly discussed. 28 refs., 3 figs

  6. Theoretical studies of the electronic properties of transition metals and transition metal compounds

    International Nuclear Information System (INIS)

    Alward, J.F. Jr.

    1976-01-01

    An efficient new technique is presented for rapidly determining a near-optimum pseudopotential for use in electronic energy band structure calculations. The electronic energy band structures of TiC and ZrC have been obtained and the corresponding reflectivity spectra are in fair agreement with the data. The TiC wavefunctions have been used to determine the electronic charge distribution in the (100) plane, and the results indicate that there is a net transfer of electronic charge from the titanium atom to the carbon atom. By also calculating the energy band structures of TiN and ZrN, and comparing with the carbide results, it was shown that the rigid-band model is not valid. Using the reflectivity data of Weaver, Lynch, and Olson, the electronic energy band structures of tantalum and vanadium were calculated. The vanadium density of valence states is in good agreement with Eastman's photoemission data. Furthermore, the Ta and V reflectivity spectra have been shown to be in good agreement with the data. Finally, the Fermi surfaces calculated for both Ta and V are in very good agreement with Fermi surface data

  7. Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron-electron interactions, application to graphene

    Science.gov (United States)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-07-01

    Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron-electron (e-e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e-e interactions. This required adapting the treatment of e-e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

  8. Runaway-electron-materials interaction studies

    International Nuclear Information System (INIS)

    Bolt, H.; Miyahara, A.

    1990-03-01

    During the operation of magnetic fusion devices it has been frequently observed that runaway electrons can cause severe damage to plasma facing components. The energy of the runaway electrons could possibly reach several 100 MeV in a next generation device with an energy content in the plasma in the order of 100 MJ. In this study effects of high energy electron - materials interaction were determined by laboratory experiments using particle beam facilities, i.e. the Electron Linear Accelerator of the Institute of Scientific and Industrial Research of Osaka University and the 10 MW Neutral Beam Injection Test Stand of the National Institute for Fusion Science. The experiments and further analyses lead to a first assessment of the damage thresholds of plasma facing materials and components under runaway electron impact. It was found that metals (stainless steel, molybdenum, tungsten) showed grain growth, crack formation and/or melting already below the threshold for crack initiation on graphite (14-33 MJ/m 2 ). Strong erosion of carbon materials would occur above 100 MJ/m 2 . Damage to metal coolant channels can occur already below an energy deposition of 100 MJ/m 2 . The energy deposited in the metal coolant channels depends on the thickness of the plasma facing carbon material D, with the shielding efficiency S of carbon approximately as S∼D 1.15 . (author) 304 refs. 12 tabs. 59 figs

  9. Multi-scale modelling and numerical simulation of electronic kinetic transport

    International Nuclear Information System (INIS)

    Duclous, R.

    2009-11-01

    This research thesis which is at the interface between numerical analysis, plasma physics and applied mathematics, deals with the kinetic modelling and numerical simulations of the electron energy transport and deposition in laser-produced plasmas, having in view the processes of fuel assembly to temperature and density conditions necessary to ignite fusion reactions. After a brief review of the processes at play in the collisional kinetic theory of plasmas, with a focus on basic models and methods to implement, couple and validate them, the author focuses on the collective aspect related to the free-streaming electron transport equation in the non-relativistic limit as well as in the relativistic regime. He discusses the numerical development and analysis of the scheme for the Vlasov-Maxwell system, and the selection of a validation procedure and numerical tests. Then, he investigates more specific aspects of the collective transport: the multi-specie transport, submitted to phase-space discontinuities. Dealing with the multi-scale physics of electron transport with collision source terms, he validates the accuracy of a fast Monte Carlo multi-grid solver for the Fokker-Planck-Landau electron-electron collision operator. He reports realistic simulations for the kinetic electron transport in the frame of the shock ignition scheme, the development and validation of a reduced electron transport angular model. He finally explores the relative importance of the processes involving electron-electron collisions at high energy by means a multi-scale reduced model with relativistic Boltzmann terms

  10. The validity of the density scaling method in primary electron transport for photon and electron beams

    International Nuclear Information System (INIS)

    Woo, M.K.; Cunningham, J.R.

    1990-01-01

    In the convolution/superposition method of photon beam dose calculations, inhomogeneities are usually handled by using some form of scaling involving the relative electron densities of the inhomogeneities. In this paper the accuracy of density scaling as applied to primary electrons generated in photon interactions is examined. Monte Carlo calculations are compared with density scaling calculations for air and cork slab inhomogeneities. For individual primary photon kernels as well as for photon interactions restricted to a thin layer, the results can differ significantly, by up to 50%, between the two calculations. However, for realistic photon beams where interactions occur throughout the whole irradiated volume, the discrepancies are much less severe. The discrepancies for the kernel calculation are attributed to the scattering characteristics of the electrons and the consequent oversimplified modeling used in the density scaling method. A technique called the kernel integration technique is developed to analyze the general effects of air and cork inhomogeneities. It is shown that the discrepancies become significant only under rather extreme conditions, such as immediately beyond the surface after a large air gap. In electron beams all the primary electrons originate from the surface of the phantom and the errors caused by simple density scaling can be much more significant. Various aspects relating to the accuracy of density scaling for air and cork slab inhomogeneities are discussed

  11. Electron scattering studies by means of various nuclear models

    International Nuclear Information System (INIS)

    Essaniyazov, Sh.; Juraev, Sh.; Ismatov, E.I.

    2006-01-01

    Full text: Let us consider a general case of various interaction processes of electrons with nuclei. The study of the scattering o electrons of nuclei is the source of information on the structure of nuclei. At collision of fast electrons with nuclei, both elastic and inelastic scattering can be observed. Elastic scattering gives information on the sizes of nuclei, whereas the electrons inelastic scattering processes give important information on the dynamical properties of nuclei. In the first case, the characteristics of excited states, energy levels, their widths and others, and in the second case, momentum distribution of nucleons and other particles in nuclei are studied. Let us denote the momentum and the energy of the incident electron before and after the scattering as k and ε, and k' and ε', respectively. The angle between the vectors k and k' is denoted as θ. The scattering process is characterized by three parameters: k, k' and θ. However, it is convenient to introduce three other parameters instead of the indicated above. They are: energy ω ε - ε' and momentum q = k - k', transferred by electron at scattering, and the scattering angle θ. It is worth of mentioning the two reasons why the study of electron scattering is very effective tool to study the nuclear structure. First of all, the character of electron interaction with nucleus is a well-known electromagnetic interaction of electron with current and charge in nucleus. Secondly, this interaction is relatively weak (e 2 /ℎc) 2 = ω 2 is possible (since the photon mass is zero). In case of electrons, at fixed energy transfer ω various momentum transfer are possible. Therefore, at electron scattering study one can establish the dependence of the matrix elements of q, which are the Fourier-representations of the charge and current densities. Thus, it is possible to determine directly the spatial distribution of charge and current in nucleus. The inelastic scattering is accompanied by

  12. Dissociative electron attachment studies on acetone

    Energy Technology Data Exchange (ETDEWEB)

    Prabhudesai, Vaibhav S., E-mail: vaibhav@tifr.res.in; Tadsare, Vishvesh; Ghosh, Sanat; Gope, Krishnendu; Davis, Daly; Krishnakumar, E. [Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2014-10-28

    Dissociative electron attachment (DEA) to acetone is studied in terms of the absolute cross section for various fragment channels in the electron energy range of 0–20 eV. H{sup −} is found to be the most dominant fragment followed by O{sup −} and OH{sup −} with only one resonance peak between 8 and 9 eV. The DEA dynamics is studied by measuring the angular distribution and kinetic energy distribution of fragment anions using Velocity Slice Imaging technique. The kinetic energy and angular distribution of H{sup −} and O{sup −} fragments suggest a many body break-up for the lone resonance observed. The ab initio calculations show that electron is captured in the multi-centered anti-bonding molecular orbital which would lead to a many body break-up of the resonance.

  13. A coincidence study between photo- and Auger electrons

    International Nuclear Information System (INIS)

    Ricz, S.; Koever, A.; Varga, D.; Molnar, J.; Aksela, S.; Jurvansuu, M.

    2000-01-01

    Complete text of publication follows. The investigation of double differential cross sections of photon induced Auger electrons provides very sensitive method for studying the rearrangement process, especially when the angular correlation between photo- and Auger electrons is also studied. Such type of measurements could reveal a new aspect in studying the electron-electron, hole-electron and photoelectron - Auger electron interactions. It enables one to separate the overlapping Auger lines belonging to different initial holes. The traditional coincidence measurement is very time consuming and causes serious calibration problems. In order to overcome these experimental difficulties a new electron-spectrometer (ESA-22) was developed in ATOMKI, Debrecen in cooperation with the Electron spectroscopy group of University of Oulu, Finland. The analyzer consists of a spherical and a cylindrical part. It is very similar to the ESA-21 analyzer. The main differences is that the focal ring can be set different diameters thus either a series of channel detectors can be used to detect the electrons at different angles or a position sensitive channel plate can be applied for simultaneous angular recording of electrons. Furthermore the outer sphere and cylinder are cut into two parts so the spectrometer is capable to analyze two independent angularly resolved electron spectra (in the 0 deg - 180 deg region) at different energy regions, simultaneously. A special electronic control and data handling electronics and software was worked out to control the analyzer. The first results were presented in. In the last year the ESA-22 electron-spectrometer was transported to the I411 beam line of MAX-II synchrotron in Lund, Sweden. The advanced properties of the spectrometer was investigated by measuring coincidences between the photoelectrons originated from the Ar L 3 subshell and the Ar Auger electrons in the 203-207 eV energy region. Fig. 1 shows the single and the coincidence spectra

  14. All that glisters is not gold: a comparison of electronic monitoring versus filled prescriptions--an observational study.

    Science.gov (United States)

    Wetzels, Gwenn E C; Nelemans, Patricia J; Schouten, Jan S A G; van Wijk, Boris L G; Prins, Martin H

    2006-02-10

    Poor compliance with antihypertensive medication is assumed to be an important reason for unsatisfactory control of blood pressure. Poor compliance is difficult to detect. Each method of measuring compliance has its own strengths and weaknesses. The aim of the present study was to compare patient compliance with antihypertensive drugs as measured by two methods, electronic monitoring versus refill compliance. 161 patients with a diagnosis of hypertension for at least a year prior to inclusion, and inadequate blood pressure control (systolic blood pressure > or = 160 mmHg and/or diastolic blood pressure > or = 95 mmHg) despite the use of antihypertensive drugs, were included. Patients' pharmacy records from 12 months prior to inclusion were obtained. Refill compliance was calculated as the number of days for which the pills were prescribed divided by the total number of days in this period. After inclusion compliance was measured with an electronic monitor that records time and date of each opening of the pillbox. Agreement between both compliance measures was calculated using Spearman's correlation coefficient and Cohen's kappa coefficient. There was very little agreement between the two measures. Whereas refill compliance showed a large range of values, compliance as measured by electronic monitoring was high in almost all patients with estimates between 90% and 100%. Cohen's kappa coefficient was 0.005. While electronic monitoring is often considered to be the gold standard for compliance measurements, our results suggest that a short-term electronic monitoring period with the patient being aware of electronic monitoring is probably insufficient to obtain valid compliance data. We conclude that there is a strong need for more studies that explore the effect of electronic monitoring on patient's compliance.

  15. Development techniques and electron optical studies of high voltage, high current electron guns

    International Nuclear Information System (INIS)

    Rangarajan, L.M.; Mahadevan, S.; Ramamurthi, S.S.

    1992-01-01

    The progress of the electron gun design, limiting to axially symmetric geometries is discussed here with a view to utilise such guns for electron accelerators. The mechanical design features leading to the physical configuration of the gun with stringent tolerances are outlined. Vacuum processing is done at pressures of 1.3x10 -5 Pa. The gun employs W-filament emitter or a cathode pellet with bombarder service. A water cooled compact faraday cup is used to measure the electron current. Electron gun geometries have been studied using the computer programme. The preveance of the gun is 0.7x10 -7 A/Vsup(1.5) at 80 kV. Developmental techniques of such pulsed electron guns are described. (author). 7 refs., 5 figs

  16. Anxiety measures validated in perinatal populations: a systematic review.

    Science.gov (United States)

    Meades, Rose; Ayers, Susan

    2011-09-01

    Research and screening of anxiety in the perinatal period is hampered by a lack of psychometric data on self-report anxiety measures used in perinatal populations. This paper aimed to review self-report measures that have been validated with perinatal women. A systematic search was carried out of four electronic databases. Additional papers were obtained through searching identified articles. Thirty studies were identified that reported validation of an anxiety measure with perinatal women. Most commonly validated self-report measures were the General Health Questionnaire (GHQ), State-Trait Anxiety Inventory (STAI), and Hospital Anxiety and Depression Scales (HADS). Of the 30 studies included, 11 used a clinical interview to provide criterion validity. Remaining studies reported one or more other forms of validity (factorial, discriminant, concurrent and predictive) or reliability. The STAI shows criterion, discriminant and predictive validity and may be most useful for research purposes as a specific measure of anxiety. The Kessler 10 (K-10) may be the best short screening measure due to its ability to differentiate anxiety disorders. The Depression Anxiety Stress Scales 21 (DASS-21) measures multiple types of distress, shows appropriate content, and remains to be validated against clinical interview in perinatal populations. Nineteen studies did not report sensitivity or specificity data. The early stages of research into perinatal anxiety, the multitude of measures in use, and methodological differences restrict comparison of measures across studies. There is a need for further validation of self-report measures of anxiety in the perinatal period to enable accurate screening and detection of anxiety symptoms and disorders. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Electronic properties of semiconductor heterostructures

    International Nuclear Information System (INIS)

    Einevoll, G.T.

    1991-02-01

    Ten papers on the electronic properties of semiconductors and semiconductor heterostructures constitute the backbone of this thesis. Four papers address the form and validity of the single-band effective mass approximation for semiconductor heterostructures. In four other papers properties of acceptor states in bulk semiconductors and semiconductor heterostructures are studied using the novel effective bond-orbital model. The last two papers deal with localized excitions. 122 refs

  18. Discomfort Intolerance Scale: A Study of Reliability and Validity

    Directory of Open Access Journals (Sweden)

    Kadir ÖZDEL

    2012-03-01

    Full Text Available Objective: Discomfort Intolerance Scale was developed by Norman B. Schmidt et al. to assess the individual differences of capacity to withstand physical perturbations or uncomfortable bodily states (2006. The aim of this study is to investigate the validity and reliability of Discomfort Intolerance Scale-Turkish Version (RDÖ. Method: From two different universities, total of 225 students (male=167, female=58 were participated in this study. In order to determine the criterion validity, Beck Anxiety Inventory (BAI and State-Trait Anxiety Inventory (STAI were used. Construct validity was evaluated by factor analysis after the Kaiser-Meyer-Olkin (KMO and Barlett test had been performed. To assess the test-retest reliability the scale was re-applied to 54 participants 6 weeks later. Results: To assess construct validity of DIS, factor analyses were performed using varimax principal components analysis with varimax rotation. The factor analysis resulted in two factors named “discomfort (in tolerance” and “discomfort avoidance”. The Cronbach’s alpha coefficient for the entire scale, discomfort-(intolerance subscale, discomfortavoidance subscale were, .592, .670, .600 respectively. Correlations between two factors of DIS, discomfort intolerance and discomfort avoidance, and Trait Anxiety Inventory of STAI (State-Trait Anxiety Inventory were statistically significant at the level of 0.05. Test-retest reliability was statistically significant at the level of 0.01. Conclusion: Analysis demonstrated that DIS had a satisfactory level of reliability and validity in Turkish university students.

  19. Quasi-linear analysis of the extraordinary electron wave destabilized by runaway electrons

    Energy Technology Data Exchange (ETDEWEB)

    Pokol, G. I.; Kómár, A.; Budai, A. [Department of Nuclear Techniques, Budapest University of Technology and Economics, Budapest (Hungary); Stahl, A.; Fülöp, T. [Department of Applied Physics, Chalmers University of Technology, Göteborg (Sweden)

    2014-10-15

    Runaway electrons with strongly anisotropic distributions present in post-disruption tokamak plasmas can destabilize the extraordinary electron (EXEL) wave. The present work investigates the dynamics of the quasi-linear evolution of the EXEL instability for a range of different plasma parameters using a model runaway distribution function valid for highly relativistic runaway electron beams produced primarily by the avalanche process. Simulations show a rapid pitch-angle scattering of the runaway electrons in the high energy tail on the 100–1000 μs time scale. Due to the wave-particle interaction, a modification to the synchrotron radiation spectrum emitted by the runaway electron population is foreseen, exposing a possible experimental detection method for such an interaction.

  20. A kinetic study of solar wind electrons

    International Nuclear Information System (INIS)

    Lie-Svendsen, Oeystein; Leer, Egil

    1996-01-01

    The evolution of the distribution function for a test population of electrons in an isothermal electron-proton corona has been studied using a Fokker-Planck description. The aim is to investigate whether a suprathermal tail forms due to the energy dependence of the Coulomb cross section. We find that a Maxwellian test population, injected into this background close to the coronal base with a temperature equal to that of the background electrons, maintains its shape throughout the transition from collision-dominated to collisionless flow. No significant suprathermal tail in the electron distribution function is seen in the outer corona

  1. Development, validation and utilisation of food-frequency questionnaires - a review.

    Science.gov (United States)

    Cade, Janet; Thompson, Rachel; Burley, Victoria; Warm, Daniel

    2002-08-01

    The purpose of this review is to provide guidance on the development, validation and use of food-frequency questionnaires (FFQs) for different study designs. It does not include any recommendations about the most appropriate method for dietary assessment (e.g. food-frequency questionnaire versus weighed record). A comprehensive search of electronic databases was carried out for publications from 1980 to 1999. Findings from the review were then commented upon and added to by a group of international experts. Recommendations have been developed to aid in the design, validation and use of FFQs. Specific details of each of these areas are discussed in the text. FFQs are being used in a variety of ways and different study designs. There is no gold standard for directly assessing the validity of FFQs. Nevertheless, the outcome of this review should help those wishing to develop or adapt an FFQ to validate it for its intended use.

  2. Test of Creative Imagination: Validity and Reliability Study

    Science.gov (United States)

    Gundogan, Aysun; Ari, Meziyet; Gonen, Mubeccel

    2013-01-01

    The purpose of this study was to investigate validity and reliability of the test of creative imagination. This study was conducted with the participation of 1000 children, aged between 9-14 and were studying in six primary schools in the city center of Denizli Province, chosen by cluster ratio sampling. In the study, it was revealed that the…

  3. SU-E-T-219: Comprehensive Validation of the Electron Monte Carlo Dose Calculation Algorithm in RayStation Treatment Planning System for An Elekta Linear Accelerator with AgilityTM Treatment Head

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yi; Park, Yang-Kyun; Doppke, Karen P. [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: This study evaluated the performance of the electron Monte Carlo dose calculation algorithm in RayStation v4.0 for an Elekta machine with Agility™ treatment head. Methods: The machine has five electron energies (6–8 MeV) and five applicators (6×6 to 25×25 cm {sup 2}). The dose (cGy/MU at d{sub max}), depth dose and profiles were measured in water using an electron diode at 100 cm SSD for nine square fields ≥2×2 cm{sup 2} and four complex fields at normal incidence, and a 14×14 cm{sup 2} field at 15° and 30° incidence. The dose was also measured for three square fields ≥4×4 cm{sup 2} at 98, 105 and 110 cm SSD. Using selected energies, the EBT3 radiochromic film was used for dose measurements in slab-shaped inhomogeneous phantoms and a breast phantom with surface curvature. The measured and calculated doses were analyzed using a gamma criterion of 3%/3 mm. Results: The calculated and measured doses varied by <3% for 116 of the 120 points, and <5% for the 4×4 cm{sup 2} field at 110 cm SSD at 9–18 MeV. The gamma analysis comparing the 105 pairs of in-water isodoses passed by >98.1%. The planar doses measured from films placed at 0.5 cm below a lung/tissue layer (12 MeV) and 1.0 cm below a bone/air layer (15 MeV) showed excellent agreement with calculations, with gamma passing by 99.9% and 98.5%, respectively. At the breast-tissue interface, the gamma passing rate is >98.8% at 12–18 MeV. The film results directly validated the accuracy of MU calculation and spatial dose distribution in presence of tissue inhomogeneity and surface curvature - situations challenging for simpler pencil-beam algorithms. Conclusion: The electron Monte Carlo algorithm in RayStation v4.0 is fully validated for clinical use for the Elekta Agility™ machine. The comprehensive validation included small fields, complex fields, oblique beams, extended distance, tissue inhomogeneity and surface curvature.

  4. Electronic implementation of a novel surveillance paradigm for ventilator-associated events. Feasibility and validation

    NARCIS (Netherlands)

    Klein Klouwenberg, Peter M. C.; van Mourik, Maaike S. M.; Ong, David S. Y.; Horn, Janneke; Schultz, Marcus J.; Cremer, Olaf L.; Bonten, Marc J. M.

    2014-01-01

    Accurate surveillance of ventilator-associated pneumonia (VAP) is hampered by subjective diagnostic criteria. A novel surveillance paradigm for ventilator-associated events (VAEs) was introduced. To determine the validity of surveillance using the new VAE algorithm. Prospective cohort study in two

  5. 21 CFR 1305.21 - Requirements for electronic orders.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Requirements for electronic orders. 1305.21... I AND II CONTROLLED SUBSTANCES Electronic Orders § 1305.21 Requirements for electronic orders. (a) To be valid, the purchaser must sign an electronic order for a Schedule I or II controlled substance...

  6. Electron emission relevant to inner-shell photoionization of condensed water studied by multi-electron coincidence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hikosaka, Y., E-mail: hikosaka@las.u-toyama.ac.jp [Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama 930-0194 (Japan); Mashiko, R.; Konosu, Y.; Soejima, K. [Department of Environmental Science, Niigata University, Niigata 950-2181 (Japan); Shigemasa, E. [UVSOR Facility, Institute for Molecular Science, Okazaki 444-8585 (Japan); SOKENDAI, Okazaki 444-8585 (Japan)

    2016-11-15

    Highlights: • Multi-electron coincidence spectroscopy is applied to the study of electron emissions from condensed H2O molecules. • Coincidence Auger spectra are obtained for different photoelectron energies. • The energy distribution of the slow electrons ejected in the Auger decay is deduced from three-fold coincidences. - Abstract: Multi-electron coincidence spectroscopy using a magnetic-bottle electron spectrometer has been applied to the study of the Auger decay following O1s photoionization of condensed H{sub 2}O molecules. Coincidence Auger spectra are obtained for three different photoelectron energy ranges. In addition, the energy distribution of the slow electrons ejected in the Auger decay of the O1s core hole is deduced from three-fold coincidences.

  7. Effect of resonant-to-bulk electron momentum transfer on the efficiency of electron-cyclotron current-drive

    International Nuclear Information System (INIS)

    Matsuda, Y.; Smith, G.R.; Cohen, R.H.

    1989-01-01

    Efficiency of current drive by electron cyclotron waves is investigated numerically by a bounce-averaged Fokker-Planck code to ellucidate the effects of momentum transfer from resonant to bulk-electrons, finite bulk temperature relative to the energy of resonant electrons, and trapped electrons. Comparisons are made with existing theories to assess their validity and quantitative difference between theory and code results. Difference of nearly a factor of 2 was found in efficiency between some theory and code results. (author)

  8. Can We Study Autonomous Driving Comfort in Moving-Base Driving Simulators? A Validation Study.

    Science.gov (United States)

    Bellem, Hanna; Klüver, Malte; Schrauf, Michael; Schöner, Hans-Peter; Hecht, Heiko; Krems, Josef F

    2017-05-01

    To lay the basis of studying autonomous driving comfort using driving simulators, we assessed the behavioral validity of two moving-base simulator configurations by contrasting them with a test-track setting. With increasing level of automation, driving comfort becomes increasingly important. Simulators provide a safe environment to study perceived comfort in autonomous driving. To date, however, no studies were conducted in relation to comfort in autonomous driving to determine the extent to which results from simulator studies can be transferred to on-road driving conditions. Participants ( N = 72) experienced six differently parameterized lane-change and deceleration maneuvers and subsequently rated the comfort of each scenario. One group of participants experienced the maneuvers on a test-track setting, whereas two other groups experienced them in one of two moving-base simulator configurations. We could demonstrate relative and absolute validity for one of the two simulator configurations. Subsequent analyses revealed that the validity of the simulator highly depends on the parameterization of the motion system. Moving-base simulation can be a useful research tool to study driving comfort in autonomous vehicles. However, our results point at a preference for subunity scaling factors for both lateral and longitudinal motion cues, which might be explained by an underestimation of speed in virtual environments. In line with previous studies, we recommend lateral- and longitudinal-motion scaling factors of approximately 50% to 60% in order to obtain valid results for both active and passive driving tasks.

  9. Study of a high power hydrogen beam diagnostic based on secondary electron emission

    Energy Technology Data Exchange (ETDEWEB)

    Sartori, E., E-mail: emanuele.sartori@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, UNIPD, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Department of Management and Engineering, University di Padova strad. S. Nicola 3, 36100 Vicenza (Italy); Panasenkov, A. [NRC, Kurchatov Institute, 1, Kurchatov Sq, Moscow 123182 (Russian Federation); Veltri, P. [Consorzio RFX (CNR, ENEA, INFN, UNIPD, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); INFN-LNL, viale dell’Università n. 2, 35020 Legnaro (Italy); Serianni, G.; Pasqualotto, R. [Consorzio RFX (CNR, ENEA, INFN, UNIPD, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy)

    2016-11-15

    In high power neutral beams for fusion, beam uniformity is an important figure of merit. Knowing the transverse power profile is essential during the initial phases of beam source operation, such as those expected for the ITER heating neutral beam (HNB) test facility. To measure it a diagnostic technique is proposed, based on the collection of secondary electrons generated by beam-surface and beam-gas interactions, by an array of positively biased collectors placed behind the calorimeter tubes. This measurement showed in the IREK test stand good proportionality to the primary beam current. To investigate the diagnostic performances in different conditions, we developed a numerical model of secondary electron emission, induced by beam particle impact on the copper tubes, and reproducing the cascade of secondary emission caused by successive electron impacts. The model is first validated against IREK measurements. It is then applied to the HNB case, to assess the locality of the measurement, the proportionality to the beam current density, and the influence of beam plasma.

  10. Estimation of hand hygiene opportunities on an adult medical ward using 24-hour camera surveillance: validation of the HOW2 Benchmark Study.

    Science.gov (United States)

    Diller, Thomas; Kelly, J William; Blackhurst, Dawn; Steed, Connie; Boeker, Sue; McElveen, Danielle C

    2014-06-01

    We previously published a formula to estimate the number of hand hygiene opportunities (HHOs) per patient-day using the World Health Organization's "Five Moments for Hand Hygiene" methodology (HOW2 Benchmark Study). HHOs can be used as a denominator for calculating hand hygiene compliance rates when product utilization data are available. This study validates the previously derived HHO estimate using 24-hour video surveillance of health care worker hand hygiene activity. The validation study utilized 24-hour video surveillance recordings of 26 patients' hospital stays to measure the actual number of HHOs per patient-day on a medicine ward in a large teaching hospital. Statistical methods were used to compare these results to those obtained by episodic observation of patient activity in the original derivation study. Total hours of data collection were 81.3 and 1,510.8, resulting in 1,740 and 4,522 HHOs in the derivation and validation studies, respectively. Comparisons of the mean and median HHOs per 24-hour period did not differ significantly. HHOs were 71.6 (95% confidence interval: 64.9-78.3) and 73.9 (95% confidence interval: 69.1-84.1), respectively. This study validates the HOW2 Benchmark Study and confirms that expected numbers of HHOs can be estimated from the unit's patient census and patient-to-nurse ratio. These data can be used as denominators in calculations of hand hygiene compliance rates from electronic monitoring using the "Five Moments for Hand Hygiene" methodology. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  11. Psychometric validation of a new measurement instrument for time-oriented patient information in electronic medical records: A questionnaire survey of physicians.

    Science.gov (United States)

    Shibuya, Akiko; Misawa, Jimpei; Maeda, Yukihiro; Ichikawa, Rie; Kamata, Michiyo; Inoue, Ryusuke; Morimoto, Tetsuji; Nakayama, Masaharu; Hishiki, Teruyoshi; Kondo, Yoshiaki

    2017-12-01

    Time is an important element in medical data. Physicians record and store information about patients' disease progress and treatment response in electronic medical records (EMRs). Because EMRs use timestamps, physicians can identify patterns over time regarding a patient's disease and treatment (eg, laboratory values and medications). However, analyses of physicians' use and satisfaction with EMRs have focused on functionality, storage, and system operation rather than the use of time-oriented information. This study aimed to understand physicians' needs regarding time-oriented patient information in EMRs in clinical practice. The reliability and validity of the items in the questionnaire were evaluated in 87 physicians at a national university hospital. Internal consistency was satisfactory (Cronbach alpha coefficient, 0.87). Four dimensions were identified in exploratory factor analysis. Correlations between the 4 dimensions supported the construct validity of the items. Scores of time-oriented patients' medical history in the 4 dimensions showed a significant association with physician age. Based on confirmatory factor analysis, associations were significant and positive (P information in EMRs, both time-oriented treatment results followed by time-oriented team information had significant positive associations. Our study suggests that 4 specific time-oriented patient information factors in EMRs are needed by physicians. Exploring physicians' needs regarding patient-specific time-oriented information may provide a better understanding of the barriers facing the adoption and use of EMRs (eg, decision-making and practice safety concerns) and lead to better acceptance of EMRs in physicians' clinical practices. © 2017 John Wiley & Sons, Ltd.

  12. A method for the direct measurement of electronic site populations in a molecular aggregate using two-dimensional electronic-vibrational spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Nicholas H. C.; Dong, Hui; Oliver, Thomas A. A.; Fleming, Graham R., E-mail: grfleming@lbl.gov [Department of Chemistry, University of California, Berkeley, California 94720 (United States); Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Kavli Energy Nanosciences Institute at Berkeley, Berkeley, California 94720 (United States)

    2015-09-28

    Two dimensional electronic spectroscopy has proved to be a valuable experimental technique to reveal electronic excitation dynamics in photosynthetic pigment-protein complexes, nanoscale semiconductors, organic photovoltaic materials, and many other types of systems. It does not, however, provide direct information concerning the spatial structure and dynamics of excitons. 2D infrared spectroscopy has become a widely used tool for studying structural dynamics but is incapable of directly providing information concerning electronic excited states. 2D electronic-vibrational (2DEV) spectroscopy provides a link between these domains, directly connecting the electronic excitation with the vibrational structure of the system under study. In this work, we derive response functions for the 2DEV spectrum of a molecular dimer and propose a method by which 2DEV spectra could be used to directly measure the electronic site populations as a function of time following the initial electronic excitation. We present results from the response function simulations which show that our proposed approach is substantially valid. This method provides, to our knowledge, the first direct experimental method for measuring the electronic excited state dynamics in the spatial domain, on the molecular scale.

  13. Extended use of electronic health records by primary care physicians: Does the electronic health record artefact matter?

    Science.gov (United States)

    Raymond, Louis; Paré, Guy; Marchand, Marie

    2017-04-01

    The deployment of electronic health record systems is deemed to play a decisive role in the transformations currently being implemented in primary care medical practices. This study aims to characterize electronic health record systems from the perspective of family physicians. To achieve this goal, we conducted a survey of physicians practising in private clinics located in Quebec, Canada. We used valid responses from 331 respondents who were found to be representative of the larger population. Data provided by the physicians using the top three electronic health record software products were analysed in order to obtain statistically adequate sub-sample sizes. Significant differences were observed among the three products with regard to their functional capability. The extent to which each of the electronic health record functionalities are used by physicians also varied significantly. Our results confirm that the electronic health record artefact 'does matter', its clinical functionalities explaining why certain physicians make more extended use of their system than others.

  14. Digital technique for the study of narrow structure in electron-atom and electron-molecule scattering

    International Nuclear Information System (INIS)

    Paske, W.C.; Shadfar, S.; Lorentz, S.R.; Steph, N.C.; Golden, D.E.

    1981-01-01

    A digital technique has been developed which allows the study of narrow structure in total electron-atom and electron-molecule scattering cross sections without requiring a highly monoenergetic electron beam, modulation of the electron gun, or phase sensitive detection. The electron current transmitted through a gas cell is digitized as the electron energy is stepped by ΔE through the energy range of interest. A transmitted electron difference signal is then obtained using a computer. As examples of this technique, the difference spectra are presented for He near 19.35 eV and for N 2 for the energy range from 10.3 to 15.0 eV. In the present case an instrumental resolution of 30 meV FWHM has been obtained

  15. Transaksi Bisnis Dalam Electronic Commerce (E-Commerce): Studi Tentang Permasalahan Hukum Dan Solusinya

    OpenAIRE

    Sanusi, M. Arsyad

    2001-01-01

    The progress of modem technology recently makes the transformation of Information and mode of communication among human beings become easy and direct, especially in the world of trade. In deed, the business facilities which can be obtained easily through e- commerce gives some advantages, but, at the same time, it also gives birth a number of crucial legal problems. First, the substantive problem swhich include problems of data massage authenticity, electronic signature, validity, privacy or ...

  16. Transaksi Bisnis dalam Electronic Commerce (E-Commerce): Studi tentang Permasalahan Hukum dan Solusinya

    OpenAIRE

    Sanusi, M. Arsyad

    2016-01-01

    The progress of modem technology recently makes the transformation of Information and mode of communication among human beings become easy and direct, especially in the world of trade. In deed, the business facilities which can be obtained easily through e- commerce gives some advantages, but, at the same time, it also gives birth a number of crucial legal problems. First, the substantive problem swhich include problems of data massage authenticity, electronic signature, validity, privacy or ...

  17. Transmission Electron Microscopy Studies of Electron-Selective Titanium Oxide Contacts in Silicon Solar Cells

    KAUST Repository

    Ali, Haider; Yang, Xinbo; Weber, Klaus; Schoenfeld, Winston V.; Davis, Kristopher O.

    2017-01-01

    In this study, the cross-section of electron-selective titanium oxide (TiO2) contacts for n-type crystalline silicon solar cells were investigated by transmission electron microscopy. It was revealed that the excellent cell efficiency of 21

  18. Studying the electronic customer relationship management and its ...

    African Journals Online (AJOL)

    Studying the electronic customer relationship management and its effect on bank quality outcomes. ... Journal of Fundamental and Applied Sciences ... Keywords: Electronic Banking, Service Quality, Customer Satisfaction, Management of

  19. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-12-01

    Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population. [JCBPR 2013; 2(3.000: 156-161

  20. Electronic health records: what are the most important barriers?

    Science.gov (United States)

    Ayatollahi, Haleh; Mirani, Nader; Haghani, Hamid

    2014-01-01

    The process of design and adoption of electronic health records may face a number of barriers. This study aimed to compare the importance of the main barriers from the experts' point of views in Iran. This survey study was completed in 2011. The potential participants (62 experts) included faculty members who worked in departments of health information technology and individuals who worked in the Ministry of Health in Iran and were in charge of the development and adoption of electronic health records. No sampling method was used in this study. Data were collected using a Likert-scale questionnaire ranging from 1 to 5. The validity of the questionnaire was established using content and face validity methods, and the reliability was calculated using Cronbach's alpha coefficient. The response rate was 51.6 percent. The participants' perspectives showed that the most important barriers in the process of design and adoption of electronic health records were technical barriers (mean = 3.84). Financial and ethical-legal barriers, with the mean value of 3.80 were other important barriers, and individual and organizational barriers, with the mean values of 3.59 and 3.50 were found to be less important than other barriers from the experts' perspectives. Strategic planning for the creation and adoption of electronic health records in the country, creating a team of experts to assess the potential barriers and develop strategies to eliminate them, and allocating financial resources can help to overcome most important barriers to the adoption of electronic health records.

  1. Effect of resonant-to-bulk electron momentum transfer on the efficiency of electron-cyclotron current drive

    International Nuclear Information System (INIS)

    Matsuda, Y.; Smith, G.R.; Cohen, R.H.

    1988-01-01

    Efficiency of current drive by electron-cyclotron waves is investigated numerically by a bounce-average Fokker-Planck code to elucidate the effects of momentum transfer from resonant to bulk electrons, finite bulk temperature relative to the energy of resonant electrons, and trapped electrons. Comparisons are made with existing theories to assess their validity and quantitative difference between theory and code results. Difference of nearly a factor of 2 was found in efficiency between some theory and code results. 4 refs., 4 figs

  2. PROMIS GH (Patient-Reported Outcomes Measurement Information System Global Health) Scale in Stroke: A Validation Study.

    Science.gov (United States)

    Katzan, Irene L; Lapin, Brittany

    2018-01-01

    The International Consortium for Health Outcomes Measurement recently included the 10-item PROMIS GH (Patient-Reported Outcomes Measurement Information System Global Health) scale as part of their recommended Standard Set of Stroke Outcome Measures. Before collection of PROMIS GH is broadly implemented, it is necessary to assess its performance in the stroke population. The objective of this study was to evaluate the psychometric properties of PROMIS GH in patients with ischemic stroke and intracerebral hemorrhage. PROMIS GH and 6 PROMIS domain scales measuring same/similar constructs were electronically collected on 1102 patients with ischemic and hemorrhagic strokes at various stages of recovery from their stroke who were seen in a cerebrovascular clinic from October 12, 2015, through June 2, 2017. Confirmatory factor analysis was performed to evaluate the adequacy of 2-factor structure of component scores. Test-retest reliability and convergent validity of PROMIS GH items and component scores were assessed. Discriminant validity and responsiveness were compared between PROMIS GH and PROMIS domain scales measuring the same or related constructs. Analyses were repeated stratified by stroke subtype and modified Rankin Scale score validity was good with significant correlations between all PROMIS GH items and PROMIS domain scales ( P 0.5) was demonstrated for 8 of the 10 PROMIS GH items. Reliability and validity remained consistent across stroke subtype and disability level (modified Rankin Scale, <2 versus ≥2). PROMIS GH exhibits acceptable performance in patients with stroke. Our findings support International Consortium for Health Outcomes Measurement recommendation to use PROMIS GH as part of the standard set of outcome measures in stroke. © 2017 American Heart Association, Inc.

  3. Electron-beam-induced-current and active secondary-electron voltage-contrast with aberration-corrected electron probes

    Energy Technology Data Exchange (ETDEWEB)

    Han, Myung-Geun, E-mail: mghan@bnl.gov [Condensed Matter Physics & Materials Science, Brookhaven National Laboratory, Upton, NY 11973 (United States); Garlow, Joseph A. [Condensed Matter Physics & Materials Science, Brookhaven National Laboratory, Upton, NY 11973 (United States); Materials Science and Engineering Department, Stony Brook University, Stony Brook, NY 11794 (United States); Marshall, Matthew S.J.; Tiano, Amanda L. [Department of Chemistry, Stony Brook University, Stony Brook, NY 11974 (United States); Wong, Stanislaus S. [Condensed Matter Physics & Materials Science, Brookhaven National Laboratory, Upton, NY 11973 (United States); Department of Chemistry, Stony Brook University, Stony Brook, NY 11974 (United States); Cheong, Sang-Wook [Department of Physics and Astronomy, Rutgers Center for Emergent Materials, Rutgers University, Piscataway, NJ 08854 (United States); Walker, Frederick J.; Ahn, Charles H. [Department of Applied Physics and Center for Research on Interface Structures and Phenomena, Yale University, New Haven, CT 06520 (United States); Department of Mechanical Engineering and Materials Science, Yale University, New Haven, CT 06520 (United States); Zhu, Yimei [Condensed Matter Physics & Materials Science, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2017-05-15

    Highlights: • Electron-beam-induced-current (EBIC) and active secondary-electron voltage-contrast (SE-VC) are demonstrated in STEM mode combined with in situ electrical biasing in a TEM. • Electrostatic potential maps in ferroelectric thin films, multiferroic nanowires, and single crystals obtained by off-axis electron holography were compared with EBIC and SE-VC data. • Simultaneous EBIC and active SE-VC performed with atomic resolution STEM are demonstrated. - Abstract: The ability to map out electrostatic potentials in materials is critical for the development and the design of nanoscale electronic and spintronic devices in modern industry. Electron holography has been an important tool for revealing electric and magnetic field distributions in microelectronics and magnetic-based memory devices, however, its utility is hindered by several practical constraints, such as charging artifacts and limitations in sensitivity and in field of view. In this article, we report electron-beam-induced-current (EBIC) and secondary-electron voltage-contrast (SE-VC) with an aberration-corrected electron probe in a transmission electron microscope (TEM), as complementary techniques to electron holography, to measure electric fields and surface potentials, respectively. These two techniques were applied to ferroelectric thin films, multiferroic nanowires, and single crystals. Electrostatic potential maps obtained by off-axis electron holography were compared with EBIC and SE-VC to show that these techniques can be used as a complementary approach to validate quantitative results obtained from electron holography analysis.

  4. The Jackson Career Explorer: Two Further Validity Studies

    Science.gov (United States)

    Schermer, Julie Aitken

    2012-01-01

    The present report consists of two further validity studies using the Jackson Career Explorer (JCE), a short form and continuous version of the Jackson Vocational Interest Survey, measuring 34 interests. The first study examined the relationships between the JCE and five personality factors, from a sample of 528 individuals. The correlations found…

  5. Study, development and validation of a dead-timeless electronic architecture concept for highly sensitive PET (Positron Emission Tomograph)

    International Nuclear Information System (INIS)

    Vert, P.E.

    2007-03-01

    Positron emission tomographs (PET) are fitted with highly capable reading electronics, which owns qualities and drawbacks. Highly accused at first as an explanation of the poor sensitivity of these imagers, the present study points out that the dead-times shared along the chains contribute to only 16 % in the data losses at a typical activity of 10 μCi/ml. The gross acquisition rates could thus be raised by 20 % through a suppression of these saturations. Looking in details at the philosophy of the acquisition procedure, a property appears to circumscribe the sensitivity even more: the timing resolution. The latter conditions, to the first order, the rejection capabilities of random events, part of the scattered ones and hence noise which is finally rated to the true coincidences the signal is made up of. Minimizing the resolving time goes through the suppression of the unneeded actors along with the adoption of a well adapted time-stamping method (optimal filtering). In doing so, the intrinsic channel resolution appears to be possibly lowered by a factor 7, reducing to 350 ps. The bottom value of the coincidence window may be narrowed as a consequence, leading to an increase of the NECR (noise equivalent count rate) by 50 per cent. At this stage, a time of flight (TOF) algorithms can be implemented. As an opportunist, it promises a reduction of the noise variance by 430 %, a gain that echoes on the NECR figure. Finally merging all these ideas allows to expect an improvement close to an order of magnitude on the NECR, with the hope of routine exams shortened by the same amount. In this context, it appeared logical to imagine a new electronics acquisition synoptic dedicated to fully pixelized PET. The number of channels blows up by the way when compared to the existing, this statement being partially balanced by the decision to fully integrate the electronics. The measures of the energy and time are planned to be performed with a single channel, with a continuous

  6. The Trojan Lifetime Champions Health Survey: Development, Validity, and Reliability

    Science.gov (United States)

    Sorenson, Shawn C.; Romano, Russell; Scholefield, Robin M.; Schroeder, E. Todd; Azen, Stanley P.; Salem, George J.

    2015-01-01

    Context Self-report questionnaires are an important method of evaluating lifespan health, exercise, and health-related quality of life (HRQL) outcomes among elite, competitive athletes. Few instruments, however, have undergone formal characterization of their psychometric properties within this population. Objective To evaluate the validity and reliability of a novel health and exercise questionnaire, the Trojan Lifetime Champions (TLC) Health Survey. Design Descriptive laboratory study. Setting A large National Collegiate Athletic Association Division I university. Patients or Other Participants A total of 63 university alumni (age range, 24 to 84 years), including former varsity collegiate athletes and a control group of nonathletes. Intervention(s) Participants completed the TLC Health Survey twice at a mean interval of 23 days with randomization to the paper or electronic version of the instrument. Main Outcome Measure(s) Content validity, feasibility of administration, test-retest reliability, parallel-form reliability between paper and electronic forms, and estimates of systematic and typical error versus differences of clinical interest were assessed across a broad range of health, exercise, and HRQL measures. Results Correlation coefficients, including intraclass correlation coefficients (ICCs) for continuous variables and κ agreement statistics for ordinal variables, for test-retest reliability averaged 0.86, 0.90, 0.80, and 0.74 for HRQL, lifetime health, recent health, and exercise variables, respectively. Correlation coefficients, again ICCs and κ, for parallel-form reliability (ie, equivalence) between paper and electronic versions averaged 0.90, 0.85, 0.85, and 0.81 for HRQL, lifetime health, recent health, and exercise variables, respectively. Typical measurement error was less than the a priori thresholds of clinical interest, and we found minimal evidence of systematic test-retest error. We found strong evidence of content validity, convergent

  7. Development of Electronic Book (E-Book EPUB-Based for Display Course

    Directory of Open Access Journals (Sweden)

    Oktafiany Widhi Astuti

    2017-09-01

    Full Text Available The aim of this research is to produce a source of learning in the form of electronic book (e-book with EPUB format for the Product Management Subject, and measuring the effectiveness of the use of e-book as a source for student learning independently. The study was conducted using the development model proposed by Sugiyono. This study used a questionnaire to obtain data validated by an expert. Students are as audience in learning using e-book based EPUB. The average of validation result and trial of effectiveness of EPUB-based e-book used calculation of joint validity which resulted percentage of 86,14% which means very valid and suitable to be used as alternative learning source for the Product Management Subject.

  8. Electron-Cloud Pinch Dynamics in Presence of Lattice Magnet Fields

    CERN Document Server

    Franchetti, G

    2011-01-01

    The pinch of the electron cloud due to a passing proton bunch was extensively studied in a field free region and in a dipolar magnetic field. For the latter study, a strong field approximation helped to formulate the equations of motion and to understand the complex electron pinch dynamics, which exhibited some similarities with the field-free situation. Here we extend the analysis to the case of electron pinch in quadrupoles and in sextupoles. We discuss the limits of validity for the strong field approximation and we evaluate the relative magnitude of the peak tune shift along the bunch expected for the different fields.

  9. Considerations for the analysis of longitudinal electronic health records linked to claims data to study the effectiveness and safety of drugs.

    Science.gov (United States)

    Lin, K J; Schneeweiss, S

    2016-08-01

    Health insurance claims and electronic health records (EHR) databases have been considered the preferred data sources with which to study drug safety and effectiveness in routine care. Linking claims data to EHR allows researchers to leverage the complementary advantages of each data source to enhance study validity. We propose a framework to evaluate the need for supplementing claims data with EHR and vice versa to optimize outcome ascertainment, exposure assessment, and confounding adjustment. © 2016 American Society for Clinical Pharmacology and Therapeutics.

  10. NATO Advanced Study Institute on Electron Crystallography

    CERN Document Server

    Weirich, Thomas E; Zou, Xiaodong

    2006-01-01

    During the last decade we have been witness to several exciting achievements in electron crystallography. This includes structural and charge density studies on organic molecules complicated inorganic and metallic materials in the amorphous, nano-, meso- and quasi-crystalline state and also development of new software, tailor-made for the special needs of electron crystallography. Moreover, these developments have been accompanied by a now available new generation of computer controlled electron microscopes equipped with high-coherent field-emission sources, cryo-specimen holders, ultra-fast CCD cameras, imaging plates, energy filters and even correctors for electron optical distortions. Thus, a fast and semi-automatic data acquisition from small sample areas, similar to what we today know from imaging plates diffraction systems in X-ray crystallography, can be envisioned for the very near future. This progress clearly shows that the contribution of electron crystallography is quite unique, as it enables to r...

  11. Development of a quality-assessment tool for experimental bruxism studies: reliability and validity.

    Science.gov (United States)

    Dawson, Andreas; Raphael, Karen G; Glaros, Alan; Axelsson, Susanna; Arima, Taro; Ernberg, Malin; Farella, Mauro; Lobbezoo, Frank; Manfredini, Daniele; Michelotti, Ambra; Svensson, Peter; List, Thomas

    2013-01-01

    To combine empirical evidence and expert opinion in a formal consensus method in order to develop a quality-assessment tool for experimental bruxism studies in systematic reviews. Tool development comprised five steps: (1) preliminary decisions, (2) item generation, (3) face-validity assessment, (4) reliability and discriminitive validity assessment, and (5) instrument refinement. The kappa value and phi-coefficient were calculated to assess inter-observer reliability and discriminative ability, respectively. Following preliminary decisions and a literature review, a list of 52 items to be considered for inclusion in the tool was compiled. Eleven experts were invited to join a Delphi panel and 10 accepted. Four Delphi rounds reduced the preliminary tool-Quality-Assessment Tool for Experimental Bruxism Studies (Qu-ATEBS)- to 8 items: study aim, study sample, control condition or group, study design, experimental bruxism task, statistics, interpretation of results, and conflict of interest statement. Consensus among the Delphi panelists yielded good face validity. Inter-observer reliability was acceptable (k = 0.77). Discriminative validity was excellent (phi coefficient 1.0; P reviews of experimental bruxism studies, exhibits face validity, excellent discriminative validity, and acceptable inter-observer reliability. Development of quality assessment tools for many other topics in the orofacial pain literature is needed and may follow the described procedure.

  12. Electronic properties of the layer III-VI semiconductors. A comparative study

    International Nuclear Information System (INIS)

    Depeursinge, Y.

    1981-01-01

    The electronic properties of the family of layer compounds InSe, GaSe and GaS by the empirical pseudopotential method have been studied. Both atomic positions, which are not accurately known from experiment, and atomic pseudopotentials are adjusted to fit the main optical and photoemission data with the further constraint that the same Se potential should be valid for InSe and GaSe, and the same Ga potential for GaS and GaSe. The charge densities have also been calculated and show that the ionicity of InSe is greater than that of GaS and GaSe, in good agreement with the Phillips electronegativity scale which predicts that InSe is 1.2 and 1.3 times more ionic than GaS and GaSe, respectively. The calculated band structures and charge densities allow a detailed discussion of the integrated and angle-resolved photoemission data as well as of the optical properties of these compounds. (author)

  13. Study of electron vibrational interaction parameters in chlorophosphate activated with Eu2+ ion

    International Nuclear Information System (INIS)

    Bhoyar, Priyanka D.; Dhoble, S.J.

    2014-01-01

    We present the results of theoretical study of photoluminescence of Eu 2+ ions activated chlorophosphate M 5.17 (PO 4 ) 3 Cl 5 :Eu 2+ with M = Ca, Sr and Ba estimating electron-vibrational interaction (EVI) parameters such as Huang–Rhys factor, effective phonon energy, Stokes shift and zero phonon line position. Validity of the calculated result was established by modeling the emission line which was found to be in good agreement with the measured photoluminescence spectrum of Eu 2+ doped chorophosphates. - Highlights: • The EVI parameters such as Huang–Rhys factor, effective phonon energy and zero phonon line position were estimated. • Eu 2+ ion emission observed in chlorophosphate. • Material analyzed in this work have intermediate Huang–Rhys factor, high Stokes shift and low effective phonon energy

  14. Toddler physical activity study: laboratory and community studies to evaluate accelerometer validity and correlates

    Directory of Open Access Journals (Sweden)

    Erin R. Hager

    2016-09-01

    Full Text Available Abstract Background Toddlerhood is an important age for physical activity (PA promotion to prevent obesity and support a physically active lifestyle throughout childhood. Accurate assessment of PA is needed to determine trends/correlates of PA, time spent in sedentary, light, or moderate-vigorous PA (MVPA, and the effectiveness of PA promotion programs. Due to the limited availability of objective measures that have been validated and evaluated for feasibility in community studies, it is unclear which subgroups of toddlers are at the highest risk for inactivity. Using Actical ankle accelerometry, the objectives of this study are to develop valid thresholds, examine feasibility, and examine demographic/ anthropometric PA correlates of MVPA among toddlers from low-income families. Methods Two studies were conducted with toddlers (12–36 months. Laboratory Study (n = 24- Two Actical accelerometers were placed on the ankle. PA was observed using the Child Activity Rating Scale (CARS, prescribed activities. Analyses included device equivalence reliability (correlation: activity counts of two Acticals, criterion-related validity (correlation: activity counts and CARS ratings, and sensitivity/specificity for thresholds. Community Study (n = 277, low-income mother-toddler dyads recruited- An Actical was worn on the ankle for > 7 days (goal >5, 24-h days. Height/weight was measured. Mothers reported demographics. Analyses included frequencies (feasibility and stepwise multiple linear regression (sMLR. Results Laboratory Study- Acticals demonstrated reliability (r = 0.980 and validity (r = 0.75. Thresholds demonstrated sensitivity (86 % and specificity (88 %. Community Study- 86 % wore accelerometer, 69 % had valid data (mean = 5.2 days. Primary reasons for missing/invalid data: refusal (14 % and wear-time ≤2 days (11 %. The MVPA threshold (>2200 cpm yielded 54 min/day. In sMLR, MVPA was associated with age (older

  15. Electron cloud buildup studies for the LHC

    CERN Document Server

    AUTHOR|(CDS)2160803; Boine-Frankenheim, Oliver

    Electron clouds can develop in accelerators operating with positively charged particles. The con- sequences of e-cloud related effects are very important for the operation of the Large Hadron Collider (LHC) at CERN, and for the design of future accelerators including the LHC luminosity upgrade (HL-LHC). High electron densities are generated by an interaction between the beam and the confining chamber. Primary electrons, that can be generated through various mecha- nisms, are accelerated by the beam and impinge on the chamber walls, thereby extracting more electrons from the material. Furthermore they also deposit their kinetic energy in the process, which has to be compensated by the cooling system. Especially in cryogenic environments, as it is the case for a large part of the LHC, high heat loads can pose a serious problem. In order to improve the understanding of the electron cloud, simulation studies are performed with the code PyECLOUD, developed at CERN. The work of the first half of the project is desc...

  16. The global status of freshwater fish age validation studies and a prioritization framework for future research

    Science.gov (United States)

    Pope, Kevin L.; Hamel, Martin J.; Pegg, Mark A.; Spurgeon, Jonathan J.

    2016-01-01

    Age information derived from calcified structures is commonly used to estimate recruitment, growth, and mortality for fish populations. Validation of daily or annual marks on age structures is often assumed, presumably due to a lack of general knowledge concerning the status of age validation studies. Therefore, the current status of freshwater fish age validation studies was summarized to show where additional effort is needed, and increase the accessibility of validation studies to researchers. In total, 1351 original peer-reviewed articles were reviewed from freshwater systems that studied age in fish. Periodicity and age validation studies were found for 88 freshwater species comprising 21 fish families. The number of age validation studies has increased over the last 30 years following previous calls for more research; however, few species have validated structures spanning all life stages. In addition, few fishes of conservation concern have validated ageing structures. A prioritization framework, using a combination of eight characteristics, is offered to direct future age validation studies and close the validation information gap. Additional study, using the offered prioritization framework, and increased availability of published studies that incorporate uncertainty when presenting research results dealing with age information are needed.

  17. Client Motivation for Therapy Scale Adaptation to Turkish: Reliability and Validity Study

    Directory of Open Access Journals (Sweden)

    Omer Ozer

    2017-03-01

    Full Text Available The purpose of this study is to adapt Client Motivation for Therapy Scale to the Turkish. Study group of the research consisted of 109 undergraduate students studying in Anadolu and Gaziosmanpasa Universities, in academic year 2014-2015. After establishing language, the validity and reliability of the scale of analysis was examined. Item-factor structure has been tested for compliance with a model by confirmatory factor analysis (CFA. Based on this, five-factor structure of Motivation for Counseling/Therapy Scale has been validated. The coefficient of the total internal consistency is found .79. As a result of the analysis for adaptation of Client Motivation for Therapy Scale to Turkish, it can be said that the scale is a reliable and valid measurement tool. It is suggested that studies on reliability and validity of Client Motivation for Therapy Scale on other samples can be made in future researches. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2017; 9(1.000: 13-30

  18. Validation of a zero-dimensional model for prediction of NOx and engine performance for electronically controlled marine two-stroke diesel engines

    DEFF Research Database (Denmark)

    Scappin, Fabio; Stefansson, Sigurður H.; Haglind, Fredrik

    2012-01-01

    The aim of this paper is to derive a methodology suitable for energy system analysis for predicting the performance and NOx emissions of marine low speed diesel engines. The paper describes a zero-dimensional model, evaluating the engine performance by means of an energy balance and a two zone...... experimental data from two MAN B&W engines; one case being data subject to engine parameter changes corresponding to simulating an electronically controlled engine; the second case providing data covering almost all model input and output parameters. The first case of validation suggests that the model can...

  19. Electronics Industry Study Report

    National Research Council Canada - National Science Library

    Belt, David; Fellows, John R; Kameru, Philip; Nazaroff, Boris-Frank A; Pauroso, Anthony; Schulz, Frederick; Ballew, Bob; Bond, Thomas; Demers, Stephy; Kirkpatrick, Steve

    2005-01-01

    This paper provides a national strategy for the US electronics industry. Electronics is one of the largest industries in the US and plays a critical role in almost every aspect of national security...

  20. Development and validation study of the Smartphone Overuse Screening Questionnaire.

    Science.gov (United States)

    Lee, Han-Kyeong; Kim, Ji-Hae; Fava, Maurizio; Mischoulon, David; Park, Jae-Hyun; Shim, Eun-Jung; Lee, Eun-Ho; Lee, Ji Hyeon; Jeon, Hong Jin

    2017-11-01

    The aim of this study was to develop a screening questionnaire that could distinguish individuals at high risk of smartphone overuse from casual users. The reliability, validity, and diagnostic ability of the Smartphone Overuse Screening Questionnaire (SOS-Q) were evaluated. Preliminary items were assessed by 50 addiction experts on-line, and 28 questions were selected. A total of 158 subjects recruited from six community centers for internet addiction participated in this study. The SOS-Q, Young's internet addiction scale, Korean scale for internet addiction, and Smartphone Scale for Smartphone Addiction (S-Scale) were used to assess the concurrent validity. Construct validity was supported by a six-factor model using an exploratory factor analysis. The internal consistency and the item-total correlations were favorable (α = 0.95, r = 0.35-0.81). The test-retest reliability was moderate (r = 0.70). The SOS-Q showed superior concurrent validity with the highest correlation between the S-Scale (r = 0.76). Receiver operating characteristic curve analysis revealed an area under the curve of 0.877. A cut-off point of 49 effectively categorized addiction high-risk group with a sensitivity of 0.81 and specificity of 0.86. Overall, the current study supports the use of SOS-Q as both a primary and supplementary measurement tool in a variety of settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Fast electron transport study for inertial confinement fusion

    International Nuclear Information System (INIS)

    Touati, Michael

    2015-01-01

    A new hybrid reduced model for relativistic electron beam transport in solids and dense plasmas is presented. It is based on the two first angular moments of the relativistic kinetic equation completed with the Minerbo maximum angular entropy closure. It takes into account collective effects with the self-generated electromagnetic fields as well as collisional effects with the slowing down of the electrons in collisions with plasmons, bound and free electrons and their angular scattering on both ions and electrons. This model allows for fast computations of relativistic electron beam transport while describing the kinetic distribution function evolution. Despite the loss of information concerning the angular distribution of the electron beam, the model reproduces analytical estimates in the academic case of a collimated and monoenergetic electron beam propagating through a warm and dense Hydrogen plasma and hybrid PIC simulation results in a realistic laser-generated electron beam transport in a solid target. The model is applied to the study of the emission of Kα photons in laser-solid experiments and to the generation of shock waves. (author) [fr

  2. The present status of the study on the validity of concurrent verbalization

    International Nuclear Information System (INIS)

    Watanabe, Megumi; Takahashi, Hideaki.

    1993-09-01

    We reviewed study on the validity of the method of verbal reports. The method of verbal reports gives us detailed information about human cognitive process as compared with observing a sequence of actions, while it is subjected to criticism for the validity as data. Ericsson and Simon proposed a model of verbalization and investigated conditions to keep verbal reports valid. Although a lot of studies quote their model as a base of adopting the method of verbal reports, verification the validity of verbal reports is incomplete because effects of verbalization is not clear. We pointed out that it is necessary to take into consideration kinds of task strategies, effects of trial repetition, effects of task difficulty to examine precisely effects of verbalization. (author)

  3. Measuring striving for understanding and learning value of geometry: a validity study

    Science.gov (United States)

    Ubuz, Behiye; Aydınyer, Yurdagül

    2017-11-01

    The current study aimed to construct a questionnaire that measures students' personality traits related to striving for understanding and learning value of geometry and then examine its psychometric properties. Through the use of multiple methods on two independent samples of 402 and 521 middle school students, two studies were performed to address this issue to provide support for its validity. In Study 1, exploratory factor analysis indicated the two-factor model. In Study 2, confirmatory factor analysis indicated the better fit of two-factor model compared to one or three-factor model. Convergent and discriminant validity evidence provided insight into the distinctiveness of the two factors. Subgroup validity evidence revealed gender differences for striving for understanding geometry trait favouring girls and grade level differences for learning value of geometry trait favouring the sixth- and seventh-grade students. Predictive validity evidence demonstrated that the striving for understanding geometry trait but not learning value of geometry trait was significantly correlated with prior mathematics achievement. In both studies, each factor and the entire questionnaire showed satisfactory reliability. In conclusion, the questionnaire was psychometrically sound.

  4. Development of caries risk assessment tool for Iranian preschoolers: A primary validation study

    Directory of Open Access Journals (Sweden)

    Shiva Mortazavi

    2017-01-01

    Full Text Available Background: The aim of the present study was to develop a dental caries risk assessment tool for Iranian preschoolers. Methods: In a validation and cross-sectional study, a random sample of 150 preschool children was involved. This study was conducted in three phases: questionnaire design (expert panel and peer evaluation, questionnaire testing (pilot evaluation and field testing, and validation study. The initial assessments include interview, dental examination, and laboratory investigations. Validity and reliability indices, content validity index (CVI, content validity ratio (CVR, impact score, and test-retest and Cronbach's alpha were measured. Decayed, missing, filled teeth (dmft scores were calculated according to the WHO guidelines. Results: The Iranian version of caries risk assessment (CRA questionnaire contained 17 items. Cronbach's alpha coefficient (0.86 indicated a suitable internal consistency. The mean scores for the CVI and the CVR were 0.87 and 0.78, respectively. The prevalence rate of dental caries in the study group was 69.3%, and the mean dmft was 4.57 (range 0–19. Conclusions: The Persian version of CRA questionnaire was adapted to the Iranian population. The findings demonstrated overall acceptable validity and also reliability in the application of test-retest. The results of the present study provide initial evidence that the designed CRA form could be a useful tool for CRA in the Iranian preschoolers.

  5. Accessing Electronic Journals.

    Science.gov (United States)

    McKay, Sharon Cline

    1999-01-01

    Discusses issues librarians need to consider when providing access to electronic journals. Topics include gateways; index and abstract services; validation and pay-per-view; title selection; integration with OPACs (online public access catalogs)or Web sites; paper availability; ownership versus access; usage restrictions; and services offered…

  6. Turkish Adaptation of the Mentorship Effectiveness Scale: A Validity and Reliability Study

    Science.gov (United States)

    Yirci, Ramazan; Karakose, Turgut; Uygun, Harun; Ozdemir, Tuncay Yavuz

    2016-01-01

    The purpose of this study is to adapt the Mentoring Relationship Effectiveness Scale to Turkish, and to conduct validity and reliability tests regarding the scale. The study group consisted of 156 university science students receiving graduate education. Construct validity and factor structure of the scale was analyzed first through exploratory…

  7. Electron tunneling in lithium-ammonia solutions probed by frequency-dependent electron spin relaxation studies.

    Science.gov (United States)

    Maeda, Kiminori; Lodge, Matthew T J; Harmer, Jeffrey; Freed, Jack H; Edwards, Peter P

    2012-06-06

    Electron transfer or quantum tunneling dynamics for excess or solvated electrons in dilute lithium-ammonia solutions have been studied by pulse electron paramagnetic resonance (EPR) spectroscopy at both X- (9.7 GHz) and W-band (94 GHz) frequencies. The electron spin-lattice (T(1)) and spin-spin (T(2)) relaxation data indicate an extremely fast transfer or quantum tunneling rate of the solvated electron in these solutions which serves to modulate the hyperfine (Fermi-contact) interaction with nitrogen nuclei in the solvation shells of ammonia molecules surrounding the localized, solvated electron. The donor and acceptor states of the solvated electron in these solutions are the initial and final electron solvation sites found before, and after, the transfer or tunneling process. To interpret and model our electron spin relaxation data from the two observation EPR frequencies requires a consideration of a multiexponential correlation function. The electron transfer or tunneling process that we monitor through the correlation time of the nitrogen Fermi-contact interaction has a time scale of (1-10) × 10(-12) s over a temperature range 230-290 K in our most dilute solution of lithium in ammonia. Two types of electron-solvent interaction mechanisms are proposed to account for our experimental findings. The dominant electron spin relaxation mechanism results from an electron tunneling process characterized by a variable donor-acceptor distance or range (consistent with such a rapidly fluctuating liquid structure) in which the solvent shell that ultimately accepts the transferring electron is formed from random, thermal fluctuations of the liquid structure in, and around, a natural hole or Bjerrum-like defect vacancy in the liquid. Following transfer and capture of the tunneling electron, further solvent-cage relaxation with a time scale of ∼10(-13) s results in a minor contribution to the electron spin relaxation times. This investigation illustrates the great

  8. Electron Tunneling in Lithium Ammonia Solutions Probed by Frequency-Dependent Electron-Spin Relaxation Studies

    Science.gov (United States)

    Maeda, Kiminori; Lodge, Matthew T.J.; Harmer, Jeffrey; Freed, Jack H.; Edwards, Peter P.

    2012-01-01

    Electron transfer or quantum tunneling dynamics for excess or solvated electrons in dilute lithium-ammonia solutions have been studied by pulse electron paramagnetic resonance (EPR) spectroscopy at both X- (9.7 GHz) and W-band (94 GHz) frequencies. The electron spin-lattice (T1) and spin-spin (T2) relaxation data indicate an extremely fast transfer or quantum tunneling rate of the solvated electron in these solutions which serves to modulate the hyperfine (Fermi-contact) interaction with nitrogen nuclei in the solvation shells of ammonia molecules surrounding the localized, solvated electron. The donor and acceptor states of the solvated electron in these solutions are the initial and final electron solvation sites found before, and after, the transfer or tunneling process. To interpret and model our electron spin relaxation data from the two observation EPR frequencies requires a consideration of a multi-exponential correlation function. The electron transfer or tunneling process that we monitor through the correlation time of the nitrogen Fermi-contact interaction has a time scale of (1–10)×10−12 s over a temperature range 230–290K in our most dilute solution of lithium in ammonia. Two types of electron-solvent interaction mechanisms are proposed to account for our experimental findings. The dominant electron spin relaxation mechanism results from an electron tunneling process characterized by a variable donor-acceptor distance or range (consistent with such a rapidly fluctuating liquid structure) in which the solvent shell that ultimately accepts the transferring electron is formed from random, thermal fluctuations of the liquid structure in, and around, a natural hole or Bjerrum-like defect vacancy in the liquid. Following transfer and capture of the tunneling electron, further solvent-cage relaxation with a timescale of ca. 10−13 s results in a minor contribution to the electron spin relaxation times. This investigation illustrates the great potential

  9. A study on the secondary electrons in a clinical electron beam

    International Nuclear Information System (INIS)

    Krithivas, G.; Rao, S.N.

    1989-01-01

    The central axis dose of a 12 MeV clinical electron beam is investigated in terms of an axial component due to primary electrons in the central ray and a lateral component due to secondary electrons originating from multiple scattering of electrons in the off-axis rays. To this effect secondary electron fluence measurements in a polystyrene medium irradiated with a collimated beam are made with a sensitive diode detector. This leads to a construction of secondary electron depth-dose profiles for beam sizes of diameters ranging from 1.7 to 17.4 cm. The results indicate that the lateral electrons account for 25% of the dose in the therapeutic region. For these electrons, the depth of dose maximum is correlated with diffusion depth and maximum lateral excursion in the medium. Dose component due to backscatter electrons at depths is also investigated using a thin-window parallel-plate ion chamber. The role of lateral and backscatter electrons in characterising central axis per cent depth-dose is discussed. (author)

  10. Optimisation of 12 MeV electron beam simulation using variance reduction technique

    International Nuclear Information System (INIS)

    Jayamani, J; Aziz, M Z Abdul; Termizi, N A S Mohd; Kamarulzaman, F N Mohd

    2017-01-01

    Monte Carlo (MC) simulation for electron beam radiotherapy consumes a long computation time. An algorithm called variance reduction technique (VRT) in MC was implemented to speed up this duration. This work focused on optimisation of VRT parameter which refers to electron range rejection and particle history. EGSnrc MC source code was used to simulate (BEAMnrc code) and validate (DOSXYZnrc code) the Siemens Primus linear accelerator model with the non-VRT parameter. The validated MC model simulation was repeated by applying VRT parameter (electron range rejection) that controlled by global electron cut-off energy 1,2 and 5 MeV using 20 × 10 7 particle history. 5 MeV range rejection generated the fastest MC simulation with 50% reduction in computation time compared to non-VRT simulation. Thus, 5 MeV electron range rejection utilized in particle history analysis ranged from 7.5 × 10 7 to 20 × 10 7 . In this study, 5 MeV electron cut-off with 10 × 10 7 particle history, the simulation was four times faster than non-VRT calculation with 1% deviation. Proper understanding and use of VRT can significantly reduce MC electron beam calculation duration at the same time preserving its accuracy. (paper)

  11. An environment-dependent semi-empirical tight binding model suitable for electron transport in bulk metals, metal alloys, metallic interfaces, and metallic nanostructures. I. Model and validation

    Energy Technology Data Exchange (ETDEWEB)

    Hegde, Ganesh, E-mail: ghegde@purdue.edu; Povolotskyi, Michael; Kubis, Tillmann; Klimeck, Gerhard, E-mail: gekco@purdue.edu [Network for Computational Nanotechnology (NCN), Department of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Boykin, Timothy [Department of Electrical and Computer Engineering, University of Alabama, Huntsville, Alabama (United States)

    2014-03-28

    Semi-empirical Tight Binding (TB) is known to be a scalable and accurate atomistic representation for electron transport for realistically extended nano-scaled semiconductor devices that might contain millions of atoms. In this paper, an environment-aware and transferable TB model suitable for electronic structure and transport simulations in technologically relevant metals, metallic alloys, metal nanostructures, and metallic interface systems are described. Part I of this paper describes the development and validation of the new TB model. The new model incorporates intra-atomic diagonal and off-diagonal elements for implicit self-consistency and greater transferability across bonding environments. The dependence of the on-site energies on strain has been obtained by appealing to the Moments Theorem that links closed electron paths in the system to energy moments of angular momentum resolved local density of states obtained ab initio. The model matches self-consistent density functional theory electronic structure results for bulk face centered cubic metals with and without strain, metallic alloys, metallic interfaces, and metallic nanostructures with high accuracy and can be used in predictive electronic structure and transport problems in metallic systems at realistically extended length scales.

  12. An environment-dependent semi-empirical tight binding model suitable for electron transport in bulk metals, metal alloys, metallic interfaces, and metallic nanostructures. I. Model and validation

    International Nuclear Information System (INIS)

    Hegde, Ganesh; Povolotskyi, Michael; Kubis, Tillmann; Klimeck, Gerhard; Boykin, Timothy

    2014-01-01

    Semi-empirical Tight Binding (TB) is known to be a scalable and accurate atomistic representation for electron transport for realistically extended nano-scaled semiconductor devices that might contain millions of atoms. In this paper, an environment-aware and transferable TB model suitable for electronic structure and transport simulations in technologically relevant metals, metallic alloys, metal nanostructures, and metallic interface systems are described. Part I of this paper describes the development and validation of the new TB model. The new model incorporates intra-atomic diagonal and off-diagonal elements for implicit self-consistency and greater transferability across bonding environments. The dependence of the on-site energies on strain has been obtained by appealing to the Moments Theorem that links closed electron paths in the system to energy moments of angular momentum resolved local density of states obtained ab initio. The model matches self-consistent density functional theory electronic structure results for bulk face centered cubic metals with and without strain, metallic alloys, metallic interfaces, and metallic nanostructures with high accuracy and can be used in predictive electronic structure and transport problems in metallic systems at realistically extended length scales

  13. An environment-dependent semi-empirical tight binding model suitable for electron transport in bulk metals, metal alloys, metallic interfaces, and metallic nanostructures. I. Model and validation

    Science.gov (United States)

    Hegde, Ganesh; Povolotskyi, Michael; Kubis, Tillmann; Boykin, Timothy; Klimeck, Gerhard

    2014-03-01

    Semi-empirical Tight Binding (TB) is known to be a scalable and accurate atomistic representation for electron transport for realistically extended nano-scaled semiconductor devices that might contain millions of atoms. In this paper, an environment-aware and transferable TB model suitable for electronic structure and transport simulations in technologically relevant metals, metallic alloys, metal nanostructures, and metallic interface systems are described. Part I of this paper describes the development and validation of the new TB model. The new model incorporates intra-atomic diagonal and off-diagonal elements for implicit self-consistency and greater transferability across bonding environments. The dependence of the on-site energies on strain has been obtained by appealing to the Moments Theorem that links closed electron paths in the system to energy moments of angular momentum resolved local density of states obtained ab initio. The model matches self-consistent density functional theory electronic structure results for bulk face centered cubic metals with and without strain, metallic alloys, metallic interfaces, and metallic nanostructures with high accuracy and can be used in predictive electronic structure and transport problems in metallic systems at realistically extended length scales.

  14. Electronic versus paper-pencil methods for assessing chemotherapy-induced peripheral neuropathy.

    Science.gov (United States)

    Knoerl, Robert; Gray, Evan; Stricker, Carrie; Mitchell, Sandra A; Kippe, Kelsey; Smith, Gloria; Dudley, William N; Lavoie Smith, Ellen M

    2017-11-01

    The aim of this study is to examine and compare with the validated, paper/pencil European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire-Chemotherapy-Induced Peripheral Neuropathy Scale (QLQ-CIPN20), the psychometric properties of three electronically administered patient reported outcome (PRO) measures of chemotherapy-induced peripheral neuropathy (CIPN): (1) the two neuropathy items from the National Cancer Institute's Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE), (2) the QLQ-CIPN20, and (3) the 0-10 Neuropathy Screening Question (NSQ). We employed a descriptive, cross-sectional design and recruited 25 women with breast cancer who were receiving neurotoxic chemotherapy at an academic hospital. Participants completed the paper/pencil QLQ-CIPN20 and electronic versions of the QLQ-CIPN20, PRO-CTCAE, and NSQ. Internal consistency reliability, intraclass correlation, and concurrent and discriminant validity analyses were conducted. The alpha coefficients for the electronic QLQ-CIPN20 sensory and motor subscales were 0.76 and 0.75. Comparison of the electronic and paper/pencil QLQ-CIPN20 subscales supported mode equivalence (intraclass correlation range >0.91). Participants who reported the presence of numbness/tingling via the single-item NSQ reported higher mean QLQ-CIPN20 sensory subscale scores (p neuropathy severity and interference items correlated well with the QLQ-CIPN20 electronic and paper/pencil sensory (r = 0.76; r = 0.70) and motor (r = 0.55; r = 0.62) subscales, and with the NSQ (r = 0.72; r = 0.44). These data support the validity of the electronically administered PRO-CTCAE neuropathy items, NSQ, and QLQ-CIPN20 for neuropathy screening in clinical practice. The electronic and paper/pencil versions of the QLQ-CIPN can be used interchangeably based on evidence of mode equivalence.

  15. The validity of vignettes in cross country health studies

    DEFF Research Database (Denmark)

    Pozzoli, Dario; Gupta, Nabanita Datta; Kristensen, Nicolai

    Cross-country comparisons of subjective assessments may be ham-pered by sub-population speci.c response style. To correct for this, the use of vignettes has become increasingly popular - notably within cross-country health studies. However, the validity of vignettes as a means to re-scale across ...... that the assumption of RC is not innocous and that our extended model improves the fit and significantly changes the cross-country rankings of health vis-á-vis the standard Chopit model.......Cross-country comparisons of subjective assessments may be ham-pered by sub-population speci.c response style. To correct for this, the use of vignettes has become increasingly popular - notably within cross-country health studies. However, the validity of vignettes as a means to re-scale across...

  16. Physical methods for studying minerals and solid materials: X-ray, electron and neutron diffraction; scanning and transmission electron microscopy; X-ray, electron and ion spectrometry

    International Nuclear Information System (INIS)

    Eberhart, J.-P.

    1976-01-01

    The following topics are discussed: theoretical aspects of radiation-matter interactions; production and measurement of radiations (X rays, electrons, neutrons); applications of radiation interactions to the study of crystalline materials. The following techniques are presented: X-ray and neutron diffraction, electron microscopy, electron diffraction, X-ray fluorescence analysis, electron probe microanalysis, surface analysis by electron emission spectrometry (ESCA and Auger electrons), scanning electron microscopy, secondary ion emission analysis [fr

  17. Inter-machine validation study of neoclassical transport modelling in medium- to high-density stellarator-heliotron plasmas

    International Nuclear Information System (INIS)

    Dinklage, A.; Beidler, C.D.; Baldzuhn, J.; Feng, Y.; Geiger, J.; Jakubowski, M.; Maaßberg, H.; Yokoyama, M.; Tanaka, K.; Satake, S.; Ida, K.; Miyazawa, J.; Morisaki, T.; Velasco, J.L.; López-Bruna, D.; Ascasíbar, E.; Arévalo, J.; López-Fraguas, A.; Gates, D.; Isaev, M.

    2013-01-01

    A comparative study of energy transport for medium- to high-density discharges in the stellarator-heliotrons TJ-II, W7-AS and LHD is carried out. The specific discharge parameters are chosen to apply a recently concluded benchmarking study of neoclassical (NC) transport coefficients (Beidler et al 2011 Nucl. Fusion 51 076001) to perform this validation study. In contrast to previous experiments at low densities for which electron transport was predominant (Yokoyama et al 2007 Nucl. Fusion 47 1213), the current discharges also exhibit significant ion energy transport. As it affects the energy transport in 3D devices, the ambipolar radial electric field is addressed as well. For the discharges described, ion-root conditions, i.e. a small negative radial electric field were found. The energy transport in the peripheral region cannot be explained by NC theory. Within a ‘core region’(r/a < 1/2 ∼ 2/3), the predicted NC energy fluxes comply with experimental findings for W7-AS. For TJ-II, compliance in the core region is found for the particle transport and the electron energy transport. For the specific LHD discharges, the core energy transport complied with NC theory except for the electron energy transport in the inward-shifted magnetic configuration. The NC radial electric field tends to agree with experimental results for all devices but is measured to be more negative in the core of both LHD and TJ-II. As a general observation, the energy confinement time approaches the gyro-Bohm-type confinement scaling ISS04 (Yamada et al 2005 Nucl. Fusion 45 1684). This work is carried out within the International Stellarator-Heliotron Profile Database (www.ipp.mpg.de/ISS and http://ishpdb.nifs.ac.jp/index.html). (paper)

  18. First principles studies of electron tunneling in proteins

    Science.gov (United States)

    Hayashi, Tomoyuki; Stuchebrukhov, Alexei A.

    2014-01-01

    A first principles study of electronic tunneling along the chain of seven Fe/S clusters in respiratory complex I, a key enzyme in the respiratory electron transport chain, is described. The broken-symmetry states of the Fe/S metal clusters calculated at both DFT and semi-empirical ZINDO levels were utilized to examine both the extremely weak electronic couplings between Fe/S clusters and the tunneling pathways, which provide a detailed atomistic-level description of the charge transfer process in the protein. One-electron tunneling approximation was found to hold within a reasonable accuracy, with only a moderate induced polarization of the core electrons. The method is demonstrated to be able to calculate accurately the coupling matrix elements as small as 10−4 cm−1. A distinct signature of the wave properties of electrons is observed as quantum interferences of multiple tunneling pathways. PMID:25383312

  19. Sci-Thur AM: YIS – 04: Stopping power-to-Cherenkov power ratios and beam quality specification for clinical Cherenkov emission dosimetry of electrons: beam-specific effects and experimental validation

    International Nuclear Information System (INIS)

    Zlateva, Yana; Seuntjens, Jan; El Naqa, Issam

    2016-01-01

    Purpose: To advance towards clinical Cherenkov emission (CE)-based dosimetry by investigating beam-specific effects on Monte Carlo-calculated electron-beam stopping power-to-CE power ratios (SCRs), addressing electron beam quality specification in terms of CE, and validating simulations with measurements. Methods: The EGSnrc user code SPRRZnrc, used to calculate Spencer-Attix stopping-power ratios, was modified to instead calculate SCRs. SCRs were calculated for 6- to 22-MeV clinical electron beams from Varian TrueBeam, Clinac 21EX, and Clinac 2100C/D accelerators. Experiments were performed with a 20-MeV electron beam from a Varian TrueBeam accelerator, using a diffraction grating spectrometer with optical fiber input and a cooled back-illuminated CCD. A fluorophore was dissolved in the water to remove CE signal anisotropy. Results: It was found that angular spread of the incident beam has little effect on the SCR (≤ 0.3% at d max ), while both the electron spectrum and photon contamination increase the SCR at shallow depths and decrease it at large depths. A universal data fit of R 50 in terms of C 50 (50% CE depth) revealed a strong linear dependence (R 2 > 0.9999). The SCR was fit with a Burns-type equation (R 2 = 0.9974, NRMSD = 0.5%). Below-threshold incident radiation was found to have minimal effect on beam quality specification (< 0.1%). Experiments and simulations were in good agreement. Conclusions: Our findings confirm the feasibility of the proposed CE dosimetry method, contingent on computation of SCRs from additional accelerators and on further experimental validation. This work constitutes an important step towards clinical high-resolution out-of-beam CE dosimetry.

  20. An atomic model of brome mosaic virus using direct electron detection and real-space optimization

    Science.gov (United States)

    Wang, Zhao; Hryc, Corey F.; Bammes, Benjamin; Afonine, Pavel V.; Jakana, Joanita; Chen, Dong-Hua; Liu, Xiangan; Baker, Matthew L.; Kao, Cheng; Ludtke, Steven J.; Schmid, Michael F.; Adams, Paul D.; Chiu, Wah

    2014-09-01

    Advances in electron cryo-microscopy have enabled structure determination of macromolecules at near-atomic resolution. However, structure determination, even using de novo methods, remains susceptible to model bias and overfitting. Here we describe a complete workflow for data acquisition, image processing, all-atom modelling and validation of brome mosaic virus, an RNA virus. Data were collected with a direct electron detector in integrating mode and an exposure beyond the traditional radiation damage limit. The final density map has a resolution of 3.8 Å as assessed by two independent data sets and maps. We used the map to derive an all-atom model with a newly implemented real-space optimization protocol. The validity of the model was verified by its match with the density map and a previous model from X-ray crystallography, as well as the internal consistency of models from independent maps. This study demonstrates a practical approach to obtain a rigorously validated atomic resolution electron cryo-microscopy structure.

  1. Quadrupole moments as measures of electron correlation in two-electron atoms

    International Nuclear Information System (INIS)

    Ceraulo, S.C.; Berry, R.S.

    1991-01-01

    We have calculated quadrupole moments, Q zz , of helium in several of its doubly excited states and in two of its singly excited Rydberg states, and of the alkaline-earth atoms Be, Mg, Ca, Sr, and Ba in their ground and low-lying excited states. The calculations use well-converged, frozen-core configuration-interaction (CI) wave functions and, for interpretive purposes, Hartree-Fock (HF) atomic wave functions and single-term, optimized, molecular rotor-vibrator (RV) wave functions. The quadrupole moments calculated using RV wave functions serve as a test of the validity of the correlated, moleculelike model, which has been used to describe the effects of electron correlation in these two-electron and pseudo-two-electron atoms. Likewise, the quadrupole moments calculated with HF wave functions test the validity of the independent-particle model. In addition to their predictive use and their application to testing simple models, the quadrupole moments calculated with CI wave functions reveal previously unavailable information about the electronic structure of these atoms. Experimental methods by which these quadrupole moments might be measured are also discussed. The quadrupole moments computed from CI wave functions are presented as predictions; measurements of Q zz have been made for only two singly excited Rydberg states of He, and a value of Q zz has been computed previously for only one of the states reported here. We present these results in the hope of stimulating others to measure some of these quadrupole moments

  2. High Pressure X-ray Absorption Studies on Correlated-Electron Systems

    International Nuclear Information System (INIS)

    Cornelius, Andrew L.

    2016-01-01

    This project used high pressure to alter the electron-electron and electron-lattice interactions in rare earth and actinide compounds. Knowledge of these properties is the starting points for a first-principles understanding of electronic and electronically related macroscopic properties. The research focused on a systematic study of x-ray absorption measurements on rare earth and actinide compounds.

  3. Assessing validity of observational intervention studies - the Benchmarking Controlled Trials.

    Science.gov (United States)

    Malmivaara, Antti

    2016-09-01

    Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. To create and pilot test a checklist for appraising methodological validity of a BCT. The checklist was created by extracting the most essential elements from the comprehensive set of criteria in the previous paper on BCTs. Also checklists and scientific papers on observational studies and respective systematic reviews were utilized. Ten BCTs published in the Lancet and in the New England Journal of Medicine were used to assess feasibility of the created checklist. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. However, the piloted checklist should be validated in further studies. Key messages Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. This paper presents a checklist for appraising methodological validity of BCTs and pilot-tests the checklist with ten BCTs published in leading medical journals. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies.

  4. Electron Beam Charge Diagnostics for Laser Plasma Accelerators

    International Nuclear Information System (INIS)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Smith, Alan; Rodgers, David; Donahue, Rich; Byrne, Warren; Leemans, Wim

    2011-01-01

    A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). First, a scintillating screen (Lanex) was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT) for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160 pC/mm 2 and 0.4 pC/(ps mm 2 ), respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within ±8%, showing that they all can provide accurate charge measurements for LPAs.

  5. Electron beam charge diagnostics for laser plasma accelerators

    Directory of Open Access Journals (Sweden)

    K. Nakamura

    2011-06-01

    Full Text Available A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs. First, a scintillating screen (Lanex was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160  pC/mm^{2} and 0.4  pC/(ps  mm^{2}, respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within ±8%, showing that they all can provide accurate charge measurements for LPAs.

  6. NASAwide electronic publishing system: Electronic printing and duplicating, stage-2 evaluation report (GSFC)

    Science.gov (United States)

    Tuey, Richard C.; Lane, Robert; Hart, Susan V.

    1995-01-01

    The NASA Scientific and Technical Information Office was assigned the responsibility to continue with the expansion of the NASAwide networked electronic duplicating effort by including the Goddard Space Flight Center (GSFC) as an additional node to the existing configuration of networked electronic duplicating systems within NASA. The subject of this report is the evaluation of a networked electronic duplicating system which meets the duplicating requirements and expands electronic publishing capabilities without increasing current operating costs. This report continues the evaluation reported in 'NASA Electronic Publishing System - Electronic Printing and Duplicating Evaluation Report' (NASA TM-106242) and 'NASA Electronic Publishing System - Stage 1 Evaluation Report' (NASA TM-106510). This report differs from the previous reports through the inclusion of an external networked desktop editing, archival, and publishing functionality which did not exist with the previous networked electronic duplicating system. Additionally, a two-phase approach to the evaluation was undertaken; the first was a paper study justifying a 90-day, on-site evaluation, and the second phase was to validate, during the 90-day evaluation, the cost benefits and productivity increases that could be achieved in an operational mode. A benchmark of the functionality of the networked electronic publishing system and external networked desktop editing, archival, and publishing system was performed under a simulated daily production environment. This report can be used to guide others in determining the most cost effective duplicating/publishing alternative through the use of cost/benefit analysis and return on investment techniques. A treatise on the use of these techniques can be found by referring to 'NASA Electronic Publishing System -Cost/Benefit Methodology' (NASA TM-106662).

  7. A coordinated two-satellite study of energetic electron precipitation events

    International Nuclear Information System (INIS)

    Imhof, W.L.; Nakano, G.H.; Gaines, E.E.; Reagan, J.B.

    1975-01-01

    A new technique for studying the spatial/temporal variations of energetic electron precipitation events is investigated. Data are presented in which precipitating electrons were measured simultaneously on two coordinated polar-orbiting satellites and the bremsstrahlung produced by the electrons precipitating into the atmosphere was observed from one of the satellites. Two electron spectrometers measuring the intensities and energy spectra of electrons of >130 keV were located on the oriented satellite 1971-089A (altitude, approx. =800 km), whereas a single similar spectrometer measuring electrons of >160 keV was located on the spinning low-altitude (approx.750 km) satellite 1972-076B. The X rays of >50 keV were measured with a 50-cm 3 germanium spectrometer placed on the 1972-076B satellite. With the coordinated data a study is made of events in which large fluctuations were observed in the precipitating energetic electron intensities. In the examples presented the satellite X ray data alone demonstrate that the spatially integrated electron influx was constant in time, and when the X ray data are combined with the direct electron measurements from the two satellites, the resulting data suggest that the major features in the flux profiles were primarily spatial in nature. The combination of X ray and electron measurements from two satellites is shown to provide an important method for studying and attempting to resolve spatial and temporal effects

  8. Theoretical study of the interplay of electron-electron interaction and disorder

    International Nuclear Information System (INIS)

    Brezini, A.; Behilil, S.

    1988-10-01

    A disordered Hubbard model with diagonal disorder is used to investigate the electron localization effects associated with both disorder and electron-electron interaction. Extensive results are reported on the ground state properties and compared to other theories. Two regimes have been found: when the electron-electron interaction u is greater than the disorder parameter w and when u < w. (author). 18 refs, 4 figs

  9. Reliability and validity of the foot and ankle outcome score: a validation study from Iran.

    Science.gov (United States)

    Negahban, Hossein; Mazaheri, Masood; Salavati, Mahyar; Sohani, Soheil Mansour; Askari, Marjan; Fanian, Hossein; Parnianpour, Mohamad

    2010-05-01

    The aims of this study were to culturally adapt and validate the Persian version of Foot and Ankle Outcome Score (FAOS) and present data on its psychometric properties for patients with different foot and ankle problems. The Persian version of FAOS was developed after a standard forward-backward translation and cultural adaptation process. The sample included 93 patients with foot and ankle disorders who were asked to complete two questionnaires: FAOS and Short-Form 36 Health Survey (SF-36). To determine test-retest reliability, 60 randomly chosen patients completed the FAOS again 2 to 6 days after the first administration. Test-retest reliability and internal consistency were assessed using intraclass correlation coefficient (ICC) and Cronbach's alpha, respectively. To evaluate convergent and divergent validity of FAOS compared to similar and dissimilar concepts of SF-36, the Spearman's rank correlation was used. Dimensionality was determined by assessing item-subscale correlation corrected for overlap. The results of test-retest reliability show that all the FAOS subscales have a very high ICC, ranging from 0.92 to 0.96. The minimum Cronbach's alpha level of 0.70 was exceeded by most subscales. The Spearman's correlation coefficient for convergent construct validity fell within 0.32 to 0.58 for the main hypotheses presented a priori between FAOS and SF-36 subscales. For dimensionality, the minimum Spearman's correlation coefficient of 0.40 was exceeded by most items. In conclusion, the results of our study show that the Persian version of FAOS seems to be suitable for Iranian patients with various foot and ankle problems especially lateral ankle sprain. Future studies are needed to establish stronger psychometric properties for patients with different foot and ankle problems.

  10. Laser-induced electron--ion recombination used to study enhanced spontaneous recombination during electron cooling

    International Nuclear Information System (INIS)

    Schramm, U.; Wolf, A.; Schuess ler, T.; Habs, D.; Schwalm, D.; Uwira, O.; Linkemann, J.; Mueller, A.

    1997-01-01

    Spontaneous recombination of highly charged ions with free electrons in merged velocity matched electron and ion beams has been observed in earlier experiments to occur at rates significantly higher than predicted by theoretical estimates. To study this enhanced spontaneous recombination, laser induced recombination spectra were measured both in velocity matched beams and in beams with well defined relative velocities, corresponding to relative electron-ion detuning energies ranging from 1 meV up to 6.5 meV where the spontaneous recombination enhancement was found to be strongly reduced. Based on a comparison with simplified calculations, the development of the recombination spectra for decreasing detuning energies indicates additional contributions at matched velocities which could be related to the energy distribution of electrons causing the spontaneous recombination rate enhancement

  11. Development of Creative Behavior Observation Form: A Study on Validity and Reliability

    Science.gov (United States)

    Dere, Zeynep; Ömeroglu, Esra

    2018-01-01

    This study, Creative Behavior Observation Form was developed to assess creativity of the children. While the study group on the reliability and validity of Creative Behavior Observation Form was being developed, 257 children in total who were at the ages of 5-6 were used as samples with stratified sampling method. Content Validity Index (CVI) and…

  12. Development and validation of stability indicating studies of ...

    African Journals Online (AJOL)

    Development and validation of stability indicating studies of paliperidone ... A simple and sensitive stability indicating HPLC method is developed for the ... The developed method was proved adequate for quantitative determination of ... Browse By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  13. Videoconference-based mini mental state examination: a validation study.

    Science.gov (United States)

    Timpano, Francesca; Pirrotta, Fabio; Bonanno, Lilla; Marino, Silvia; Marra, Angela; Bramanti, Placido; Lanzafame, Pietro

    2013-12-01

    Neuropsychological testing is a prime criterion of good practice to document cognitive deficits in a rapidly aging population. Telecommunication technologies may overcome limitations related to test administration. We compared performance of the Italian videoconference-based version of the Mini Mental State Examination (VMMSE) with performance of the standard MMSE administered face-to-face (F2F), to validate the Italian version of the 28-item VMMSE. To validate the Italian version of the VMMSE, we compared its performance with standard F2F. The sample (n=342) was administered three VMMSEs within 6 weeks after F2F testing. We identified the optimal cutoff through the receiver operating characteristic curve, as well as the VMMSE consistency through inter- and intrarater reliability (Inter/RR and Intra/RR) analysis. We found high levels of sensitivity and specificity for the optimal VMMSE cutoff identification and an accuracy of 0.96 (95% confidence interval 0.94-0.98). Intra/RR and inter/RR were highly significant. This study demonstrates that VMMSE is a valid instrument in clinical and research screening and monitoring of subjects affected by cognitive disorders. This study shows a significant correlation between videoconference assessment and the F2F one, providing an important impetus to expand studies and the knowledge about the usefulness of tele-assistance services. Our findings have important implications for both longitudinal assistance and clinical care of demented patients.

  14. Electronic astronomical information handling and flexible publishing.

    Science.gov (United States)

    Heck, A.

    The current dramatic evolution in information technology is bringing major modifications in the way scientists work and communicate. The concept of electronic information handling encompasses the diverse types of information, the different media, as well as the various communication methodologies and technologies. It ranges from the very collection of data until the final publication of results and sharing of knowledge. New problems and challenges result also from the new information culture, especially on legal, ethical, and educational grounds. Electronic publishing will have to diverge from an electronic version of contributions on paper and will be part of a more general flexible-publishing policy. The benefits of private publishing are questioned. The procedures for validating published material and for evaluating scientific activities will have to be adjusted too. Provision of electronic refereed information independently from commercial publishers in now feasible. Scientists and scientific institutions have now the possibility to run an efficient information server with validated (refereed) material without the help of a commercial publishers.

  15. Review article: what makes a good healthcare quality indicator? A systematic review and validation study.

    Science.gov (United States)

    Jones, Peter; Shepherd, Michael; Wells, Susan; Le Fevre, James; Ameratunga, Shanthi

    2014-04-01

    Indicators measuring aspects of performance to assess quality of care are often chosen arbitrarily. The present study aimed to determine what should be considered when selecting healthcare quality indicators, particularly focusing on the application to emergency medicine. Structured searches of electronic databases were supplemented by website searches of quality of care and benchmarking organisations, citation searches and discussions with experts. Candidate attributes of 'good' healthcare indicators were extracted independently by two authors. The validity of each attribute was independently assessed by 16 experts in quality of care and emergency medicine. Valid and reliable attributes were included in a critical appraisal tool for healthcare quality indicators, which was piloted by emergency medicine specialists. Twenty-three attributes were identified, and all were rated moderate to extremely important by an expert panel. The reliability was high: alpha = 0.98. Twelve existing tools explicitly stated a median (range) of 14 (8-17) attributes. A critical appraisal tool incorporating all the attributes was developed. This was piloted by four emergency medicine specialists who were asked to appraise and rank a set of six candidate indicators. Although using the tool took more time than implicit gestalt decision making: median (interquartile range) 190 (43-352) min versus 17.5 (3-34) min, their rankings changed after using the tool. To inform the appraisal of quality improvement indicators for emergency medicine, a comprehensive list of indicator attributes was identified, validated, developed into a tool and piloted. Although expert consensus is still required, this tool provides an explicit basis for discussions around indicator selection. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  16. Consideration of Relativistic Dynamics in High-Energy Electron Coolers

    CERN Document Server

    Bruhwiler, David L

    2005-01-01

    A proposed electron cooler for RHIC would use ~55 MeV electrons to cool fully-ionized 100 GeV/nucleon gold ions.* At two locations in the collider ring, the electrons and ions will co-propagate for ~13 m, with velocities close to c and gamma>100. To lowest-order, one can Lorentz transform all physical quantities into the beam frame and calculate the dynamical friction forces assuming a nonrelativisitc, electrostatic plasma. However, we show that nonlinear space charge forces of the bunched electron beam on the ions must be calculated relativistically, because an electrostatic beam-frame calculation is not valid for such short interaction times. The validity of nonrelativistic friction force calculations must also be considered. Further, the transverse thermal velocities of the high-charge (~20 nC) electron bunch are large enough that some electrons have marginally relativistic velocities, even in the beam frame. Hence, we consider relativistic binary collisions – treating the model problem of ...

  17. A Systematic Review on the Validity of Teledentistry.

    Science.gov (United States)

    Alabdullah, Jafar H; Daniel, Susan J

    2018-01-05

    The aim of this systematic review was to evaluate the validity of using teledentistry in oral care examination and diagnosis. In June 2016, a systematic search of the literature was conducted without time restrictions in three electronic databases (Ebscohost, Pubmed, and Scopus). Two reviewers screened the retrieved articles first by title and then by abstract to determine relevant articles for full text review. Studies included were as follows: (1) related to teledentistry, (2) available in full text and English, (3) compared teledentistry application to a gold standard, and (4) provided clear statistical tests for validity. The methodological quality of studies was determined using the "Quality Assessment of Studies of Diagnostic Accuracy (QUADAS)." Seventy-nine studies met the initial search criteria. Following removal of duplicate articles, only 58 were remaining and reviewed by title and abstract, yielding 14 full-text articles. Nine of the full-text articles met the inclusion criteria. Results of the QUADAS assessment varied from 9 to 13 out of 14 items; therefore, studies demonstrated high quality (>60%). Validity of teledentistry varied and is reported by range for the following statistics: sensitivity (n = 8, 25-100%), specificity (n = 7, 68-100%), positive predictive value (n = 5, 57-100%), and negative predictive value (n = 5, 50-100%). Kappa statistics were also reported for evaluation of reliability between gold standard and teledentistry examination (n = 6, 46-93%). Teledentistry could be comparable to face-to-face for oral screening, especially in school-based programs, rural areas and areas with limited access to care, and long-term care facilities. Identification of oral diseases, referrals, and teleconsultations are possible and valid. The need for methodologically designed studies with appropriate statistical tests to determine the validity of teledentistry exists.

  18. An investigation on the role of brand equity on electronic acceptance

    Directory of Open Access Journals (Sweden)

    Hosseinali Aziziha

    2014-03-01

    Full Text Available This paper presents an empirical study to investigate the effect of brand equity on customer’s adoption of electronic banking. The proposed study uses a standard questionnaire for measuring brand equity, which consists of five items including brand associate, brand awareness, quality perception and brand loyalty. The study also uses another questionnaire, which measures electronic acceptance and both questionnaires are designed in Likert scale. Cronbach alphas for brand equity and electronic acceptance are measured as 0.83 and 0.75, which are above the acceptance level of 0.70. Therefore, we can confirm the validity of both questionnaires. The study is implemented among 384 regular customers of one of Iranian banks, randomly and using Spearman correlation ratio as well as stepwise regression techniques, the study has detected a positive and meaningful relationship between brand equity and customer’s adoption on electronic banking.

  19. The theoretical study of the optical klystron free electron laser

    International Nuclear Information System (INIS)

    Yang Zhenhua

    2001-01-01

    The work of the theoretical study and numerical simulation of optical klystron free electron laser is supported by National 863 Research Development Program and National Science Foundation of China. The object of studying UV band free electron laser (FEL) is to understand the physical law of optical klystron FEL and to gain experience for design. A three-dimensional code OPFEL are made and it is approved that the code is correct completely. The magnetic field of the optical klystron, the energy modulation of the electron beam, the density modulation of the electron beam, spontaneous emission of the electron beam in optical klystron, the harmonic super-radiation of the electron beam, and the effects of the undulator magnetic field error on modulation of the electron beam energy are simulated. These results are useful for the future experiments

  20. Negative atomic halogens incident on argon and molecular nitrogen: electron detachment studies

    International Nuclear Information System (INIS)

    Jalbert, G; Medina, A; Magalhaes, S D; Wolff, W; Barros, A L F de; Carrilho, P; Rocha, A B; Faria, N V de Castro

    2007-01-01

    During the last years we have measured total detachment cross sections of atomic and cluster anions colliding with gases in the velocity range of 0.2 to 1.8 a.u. In particular, we measured negative atomic halogens incident on argon and molecular nitrogen. These last data are for the first time analyzed using the simple semi-classical model that we have developed. For that purpose, the values of elastic plus inelastic cross sections for impact of free electrons on Ar and N 2 , the latter showing a shape resonance, convoluted with the anion's outermost electron momentum distribution yielded the overall shape of the anion cross sections. Inclusion of a velocity independent additive term, interpreted as an effective area of the collision region, led to accurate absolute cross section values. The high affinity of the halogens and the existence of a not well described resonance in the e-N 2 collision, are characteristics that may be used to delimit the scope and validity of the model

  1. Nonlocal electron heat relaxation in a plasma shock at arbitrary ionization number

    International Nuclear Information System (INIS)

    Ramirez, J.; Sanmartin, J.R.; Fernandez-Feria, R.

    1993-01-01

    A recently obtained nonlocal expression for the electron heat flux valid for arbitrary ionization numbers Z is used to study the structure of a plane shock wave in a fully ionized plasma. Nonlocal effects are only important in the foot of the electronic preheating region, where the electron temperature gradient is the steepest. The results are quantified as a function of a characteristic Knudsen number of that region. This work also generalizes to arbitrary values of Z previous results on plasma shock wave structure

  2. Electron microscopy methods in studies of cultural heritage sites

    Science.gov (United States)

    Vasiliev, A. L.; Kovalchuk, M. V.; Yatsishina, E. B.

    2016-11-01

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient "nanotechnologies"; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  3. Study of the hollow cathode plasma electron-gun

    International Nuclear Information System (INIS)

    Zhang Yonghui; Jiang Jinsheng; Chang Anbi

    2003-01-01

    For developing a novel high-current, long pulse width electron source, the theoretics and mechanism of the hollow cathode plasma electron-gun are analyzed in detail in this paper, the structure and the physical process of hollow cathode plasma electron-gun are also studied. This gun overcomes the limitations of most high-power microwave tubes, which employ either thermionic cathodes that produce low current-density beams because of the limitation of the space charge, or field-emission cathodes that offer high current density but provide only short pulse width because of plasma closure of the accelerating gap. In the theories studying on hollow cathode plasma electron-gun, the characteristic of the hollow-cathode discharge is introduced, the action during the forming of plasma of the stimulating electrode and the modulating anode are discussed, the movement of electrons and ions and the primary parameters are analyzed, and the formulas of the electric field, beam current density and the stabilization conditions of the beam current are also presented in this paper. The numerical simulation is carried out based on Poisson's equation, and the equations of current continuity and movement. And the optimized result is reported. On this basis, we have designed a hollow-cathode-plasma electron-gun, whose output pulse current is 2 kA, and pulse width is 1 microsecond

  4. A new theoretical model for scattering of electrons by molecules. 1

    International Nuclear Information System (INIS)

    Peixoto, E.M.A.; Mu-tao, L.; Nogueira, J.C.

    1975-01-01

    A new theoretical model for electron-molecule scattering is suggested. The e-H 2 scattering is studied and the superiority of the new model over the commonly used Independent Atom Model (IAM) is demonstrated. Comparing theoretical and experimental data for 40keV electrons scattered by H 2 utilizing the new model, its validity is proved, while Partial Wave and First Born calculations, employing the Independent Atom Model, strongly deviated from the experiment [pt

  5. Topside electron density at low latitudes

    International Nuclear Information System (INIS)

    Ezquer, R.G.; Cabrera, M.A.; Flores, R.F.; Mosert, M.

    2002-01-01

    The validity of IRI to predict the electron density at the topside electron density profile over the low latitude region is checked. The comparison with measurements obtained with the Taiyo satellite during low solar activity shows that, the disagreement between prediction and measurement is lower than 40% for 70% of considered cases. These IRI predictions are better than those obtained in a previous work at the southern peak of the equatorial anomaly for high solar activity. Additional studies for low solar activity, using ionosonde data as input parameters in the model, are needed in order to check if the observed deviations are due to the predicted peak characteristics or to the predicted shape of the topside profile. (author)

  6. Teachers' Engagement at Work: An International Validation Study

    Science.gov (United States)

    Klassen, Robert M.; Aldhafri, Said; Mansfield, Caroline F.; Purwanto, Edy; Siu, Angela F. Y.; Wong, Marina W.; Woods-McConney, Amanda

    2012-01-01

    This study explored the validity of the Utrecht Work Engagement Scale in a sample of 853 practicing teachers from Australia, Canada, China (Hong Kong), Indonesia, and Oman. The authors used multigroup confirmatory factor analysis to test the factor structure and measurement invariance across settings, after which they examined the relationships…

  7. Hazing DEOCS 4.1 Construct Validity Summary

    Science.gov (United States)

    2017-08-01

    Hazing DEOCS 4.1 Construct Validity Summary DEFENSE EQUAL OPPORTUNITY MANAGEMENT INSTITUTE DIRECTORATE OF...water; and the forced consumption of food , alcohol, drugs, or any other substance. Hazing can be conducted through the use of electronic devices or

  8. Study of electronic field emission from large surfaces under static operating conditions and hyper-frequency

    International Nuclear Information System (INIS)

    Luong, M.

    1997-09-01

    The enhanced electronic field emission from large area metallic surfaces lowers performances of industrial devices that have to sustain high electric field under vacuum. Despite of numerous investigations in the past, the mechanisms of such an emission have never been well clarified. Recently, research in our laboratory has pointed out the importance played by conducting sites (particles and protrusions). A refined geometrical model, called superposed protrusions model has been proposed to explain the enhanced emission by local field enhancement. As a logical continuation, the present work aims at testing this model and, in the same time, investigating the means to suppress the emission where it is undesirable. Thus, we have showed: the cause of current fluctuations in a continuous field regime (DC), the identity of emission characteristics (β, A e ) in both radiofrequency (RF) and DC regimes, the effectiveness of a thermal treatment by extern high density electronic bombardment, the effectiveness of a mechanical treatment by high pressure rinsing with ultra pure water, the mechanisms and limits of an in situ RF processing. Furthermore, the electronic emission from insulating particles has also been studied concurrently with a spectral analysis of the associated luminous emission. Finally, the refined geometrical model for conducting sites is reinforced while another model is proposed for some insulating sites. Several emission suppressing treatments has been explored and validated. At last, the characteristic of a RF pulsed field emitted electron beam has been checked for the first time as a possible application of such a field emission. (author)

  9. Study and realization of an electron linear accelerator. Dynamics of accelerated electrons

    International Nuclear Information System (INIS)

    Bernard, J.

    1966-12-01

    The theoretical characteristics of the electron linear accelerator are: 30 MeV for the energy W S and 250 mA for the peak current I c . The main utilization is the intense production of fast neutrons by the reactions (γ,n) and (γ,f) induced in a target of natural uranium by the accelerated electrons. In the first part of the thesis, relative to the study and the realization of the accelerator, a new equation of dispersion is established analytically when the guide is loaded with round-edged irises. The relation is compared with the equation established by CHU and Hansen, WALKINSHAW, KVASIL in the case of a guide loaded with flat-edged irises. The experimental and theoretical curves of dispersion are compared. The accuracy of every relation of dispersion is estimated. The second part of the thesis is relative to the theoretical study of the electrons dynamics in the guide; it allows the derivation of the parameters of the beam: dispersion of phase, energy, dispersion of energy and the relation W S = f (I c ). The results relative to the first experiments are given and compared with the theoretical expectations. (author) [fr

  10. Progress in Fast Ignition Studies with Electrons and Protons

    Science.gov (United States)

    MacKinnon, A. J.; Akli, K. U.; Bartal, T.; Beg, F. N.; Chawla, S.; Chen, C. D.; Chen, H.; Chen, S.; Chowdhury, E.; Fedosejevs, R.; Freeman, R. R.; Hey, D.; Higginson, D.; Key, M. H.; King, J. A.; Link, A.; Ma, T.; MacPhee, A. G.; Offermann, D.; Ovchinnikov, V.; Pasley, J.; Patel, P. K.; Ping, Y.; Schumacher, D. W.; Stephens, R. B.; Tsui, Y. Y.; Wei, M. S.; Van Woerkom, L. D.

    2009-09-01

    Isochoric heating of inertially confined fusion plasmas by laser driven MeV electrons or protons is an area of great topical interest in the inertial confinement fusion community, particularly with respect to the fast ignition (FI) concept for initiating burn in a fusion capsule. In order to investigate critical aspects needed for a FI point design, experiments were performed to study 1) laser-to-electrons or protons conversion issues and 2) laser-cone interactions including prepulse effects. A large suite of diagnostics was utilized to study these important parameters. Using cone—wire surrogate targets it is found that pre-pulse levels on medium scale lasers such as Titan at Lawrence Livermore National Laboratory produce long scale length plasmas that strongly effect coupling of the laser to FI relevant electrons inside cones. The cone wall thickness also affects coupling to the wire. Conversion efficiency to protons has also been measured and modeled as a function of target thickness, material. Conclusions from the proton and electron source experiments will be presented. Recent advances in modeling electron transport and innovative target designs for reducing igniter energy and increasing gain curves will also be discussed. In conclusion, a program of study will be presented based on understanding the fundamental physics of the electron or proton source relevant to FI.

  11. Study of distribution of electron density in heteropolymolybdates by method of X-ray electron spectroscopy

    International Nuclear Information System (INIS)

    Molchanov, V.N.; Kazanskij, L.P.; Torchenkova, E.A.; Spitsyn, V.I.

    1978-01-01

    X-ray electron spectra of some iso- and heteropolymolybdates relating to different structure types are investigated to study electron structure of complex polyoxyion-heteropolyanions. Binding energies of Modsub(5/2) and 01s-electrons in iso- and heteropolycompounds line are measured and their interdependence is detected. The effective charge of oxygen and molybdenum atoms in heteropolymolybdates increases with decreasing a number of external sphere cations per an oxygen atom and a number of Mo=0 multiple bonds

  12. Electronic Structure Approach to Tunable Electronic Properties of Hybrid Organic-Inorganic Perovskites

    Science.gov (United States)

    Liu, Garnett; Huhn, William; Mitzi, David B.; Kanai, Yosuke; Blum, Volker

    We present a study of the electronic structure of layered hybrid organic-inorganic perovskite (HOIP) materials using all-electron density-functional theory. Varying the nature of the organic and inorganic layers should enable systematically fine-tuning the carrier properties of each component. Using the HSE06 hybrid density functional including spin-orbit coupling (SOC), we validate the principle of tuning subsystem-specific parts of the electron band structures and densities of states in CH3NH3PbX3 (X=Cl, Br, I) compared to a modified organic component in layered (C6H5C2H4NH3) 2PbX4 (X=Cl, Br, I) and C20H22S4N2PbX4 (X=Cl, Br, I). We show that tunable shifts of electronic levels indeed arise by varying Cl, Br, I as the inorganic components, and CH3NH3+ , C6H5C2H4NH3+ , C20H22S4N22 + as the organic components. SOC is found to play an important role in splitting the conduction bands of the HOIP compounds investigated here. The frontier orbitals of the halide shift, increasing the gap, when Cl is substituted for Br and I.

  13. Simulation studies on stability of hot electron plasma

    International Nuclear Information System (INIS)

    Ohsawa, Yukiharu

    1985-01-01

    Stability of a hot electron plasma in an NBT(EBT)-like geometry is studied by using a 2-1/2 dimensional relativistic, electromagnetic particle code. For the low-frequency hot electron interchange mode, comparison of the simulation results with the analytical predictions of linear stability theory show fairly good agreement with the magnitude of the growth rates calculated without hot electron finite Larmor radius effects. Strong stabilizing effects by finite Larmor radius of the hot electrons are observed for short wavelength modes. As for the high-frequency hot electron interchange mode, there is a discrepancy between the simulation results and the theory. The high-frequency instability is not observed though a parameter regime is chosen in which the high-frequency hot electron interchange mode is theoretically predicted to grow. Strong cross-field diffusion in a poloidal direction of the hot electrons might explain the stability. Each particle has a magnetic drift velocity, and the speed of the magnetic drift is proportional to the kinetic energy of each particle. Hence, if the particles have high temperature, the spread of the magnetic drift velocity is large. This causes a strong cross-field diffusion of the hot electrons. In the simulation for this interchange mode, an enhanced temperature relaxation is observed between the hot and cold electrons although the theoretically predicted high frequency modes are stable. (Nogami, K.)

  14. 29 CFR 1607.5 - General standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ...) (hereinafter “A.P.A. Standards”) and standard textbooks and journals in the field of personnel selection. D... market and the job should be considered in the determination of when a validity study is outdated. ...

  15. Superconductivity on the border of itinerant-electron ferromagnetism in UGe2

    NARCIS (Netherlands)

    Saxena, SS; Ahilan, K; Grosche, FM; Haselwimmer, RKW; Steiner, MJ; Pugh, E; Walker, IR; Julian, [No Value; Monthoux, P; Lonzarich, GG; Huxley, A; Sheikin, [No Value; Braithwaite, D; Flouquet, J

    2000-01-01

    The absence of simple examples of superconductivity adjoining itinerant-electron ferromagnetism in the phase diagram has for many years cast doubt on the validity of conventional models of magnetically mediated superconductivity. On closer examination, however, very few systems have been studied in

  16. Electron impact study of potassium hydroxide

    International Nuclear Information System (INIS)

    Vuskovic, L.; Trajmar, S.

    1979-01-01

    An ''elastic'' scattering study for low impact energies (5--20 ev) is reported for electron impact excitation of KOH. The ''elastic'' scattering is regarded as the sum of elastic rotational and vibrational contributions to the scattering

  17. Weak localization and electron-electron interaction in modulation doped GaAs/AlGaAs heterostructures

    International Nuclear Information System (INIS)

    Taboryski, R.; Lindelof, P.E.

    1990-01-01

    The first heterostructure wafer only had one electronic subband at the GaAs/AlGaAs interface populated. Weak localization magnetoresistance was interpreted by a theory valid to relatively high magnetic fields and also valid for electrons with a long mean free path. The adjustable parameter in fitting the magnetoresistance was in each case the phasebreaking relaxation time, which could then subsequently be plotted as a function of temperature. The temperature dependence of the phasebreaking rate could be interpreted on the basic of existing theories, but the residual relaxation rate at the lowest temperature remains so far unexplained. Already at low magnetic fields the weak localization magnetoresistance saturates, indicating a complete quench of weak localization. We find that the value of saturation (i.e. the total weak localization at the appropriate temperature) was smaller than predicted by the existing theories. At magnetic fields of the order of the inverse electron mobility, a quadratic magnetoresistance show up in our experiments. This quadratic magnetoresistance corresponds to corrections to the conductivity of the order of e 2 /h. Whereas we find that the temperature dependence of this conductivity correction is well in agreement with predicted effects of electron-electron interaction, the dependence on mobility, which we can measure via our ion implantation, is larger than any existing theory predicts, yet still in the ballpark of the conductance quantum. (orig./BHO)

  18. Being an Informed Consumer of Health Information and Assessment of Electronic Health Literacy in a National Sample of Internet Users: Validity and Reliability of the e-HLS Instrument.

    Science.gov (United States)

    Seçkin, Gül; Yeatts, Dale; Hughes, Susan; Hudson, Cassie; Bell, Valarie

    2016-07-11

    The Internet, with its capacity to provide information that transcends time and space barriers, continues to transform how people find and apply information to their own lives. With the current explosion in electronic sources of health information, including thousands of websites and hundreds of mobile phone health apps, electronic health literacy is gaining an increasing prominence in health and medical research. An important dimension of electronic health literacy is the ability to appraise the quality of information that will facilitate everyday health care decisions. Health information seekers explore their care options by gathering information from health websites, blogs, Web-based forums, social networking websites, and advertisements, despite the fact that information quality on the Internet varies greatly. Nonetheless, research has lagged behind in establishing multidimensional instruments, in part due to the evolving construct of health literacy itself. The purpose of this study was to examine psychometric properties of a new electronic health literacy (ehealth literacy) measure in a national sample of Internet users with specific attention to older users. Our paper is motivated by the fact that ehealth literacy is an underinvestigated area of inquiry. Our sample was drawn from a panel of more than 55,000 participants maintained by Knowledge Networks, the largest national probability-based research panel for Web-based surveys. We examined the factor structure of a 19-item electronic Health Literacy Scale (e-HLS) through exploratory factor analysis (EFA) and confirmatory factor analysis, internal consistency reliability, and construct validity on sample of adults (n=710) and a subsample of older adults (n=194). The AMOS graphics program 21.0 was used to construct a measurement model, linking latent factors obtained from EFA with 19 indicators to determine whether this factor structure achieved a good fit with our entire sample and the subsample (age ≥ 60

  19. Study of fast electrons from hard-X radiation

    International Nuclear Information System (INIS)

    Arslanbekov, R.

    1995-01-01

    The goal of this thesis is the study of fast electron dynamics by means of the hard X-ray diagnosis installed in TORE SUPRA and numerical simulations. Fast electrons are generated in the plasma in the presence of the injected lower hybrid (LH) waves. Two aspects are studied in detail: the lower hybrid wave propagation and absorption in a periodically perturbed media and 2-D Fokker-Planck modelling of the fast electron dynamics in the presence of the LH power. Ripple effects on lower hybrid wave propagation and absorption are investigated using the ray tracing technique. A cylindrical equilibrium is first studied and a strong modification of the ray dynamics is predicted. Calculations are carried out in a real toroidal geometry corresponding to TORE SUPRA. It is shown that the lack of toroidal axisymmetry of the magnetic field may result in a modification of the ray evolution even if the global ray evolution is governed by the larger poloidal inhomogeneity. Simulation of LH experiments are performed for TORE SUPRA tokamak which has a large magnetic ripple (7% at the plasma edge). By considering ripple perturbation in LH current drive simulations, a better agreement is found with experimental results, in particular with the hard-X spectra and the current density profiles. In the second part of the thesis, a 2-D modeling of the fast electron dynamics in the velocity phase space is considered, based on the 2-D relativistic electron Fokker-Planck equation. Electron distribution functions obtained are used to calculate non-thermal Bremsstrahlung emission for different TORE SUPRA shots in a wide range of experimental conditions. (J.S.). 168 refs., 93 figs., 1 tab., 3 appendix

  20. A Validity Study of the Self-Esteem Inventory.

    Science.gov (United States)

    Landis, H. John

    Results of this validation study of a slightly modified version of the Coppersmith Self-Esteem Inventory substantiate its use with seventh graders to assess Goal I (concerning self-understanding and appreciation of self-worth) of the Educational Quality Assessment Program in Pennsylvania. Appendixes include the definition and rationale for Goal I,…

  1. The accuracy and efficiency of electronic screening for recruitment into a clinical trial on COPD.

    Science.gov (United States)

    Schmickl, Christopher N; Li, Man; Li, Guangxi; Wetzstein, Marnie M; Herasevich, Vitaly; Gajic, Ognjen; Benzo, Roberto P

    2011-10-01

    Participant recruitment is an important process in successful conduct of randomized controlled trials. To facilitate enrollment into a National Institutes of Health-sponsored clinical trial involving patients with chronic obstructive pulmonary disease (COPD), we developed and prospectively validated an automated electronic screening tool based on boolean free-text search of admission notes in electronic medical records. During a 2-week validation period, all patients admitted to prespecified general medical services were screened for eligibility by both the electronic screening tool and a COPD nurse. Group discussion was the gold standard for confirmation of true-positive results. Compared with the gold standard, electronic screening yielded 100% sensitivity, 92% specificity, 100% negative predictive value, and 72% positive predictive value. Compared with traditional manual screening, electronic screening demonstrated time-saving potential of 76%. Thus, the electronic screening tool accurately identifies potential study subjects and improves efficiency of patient accrual for a clinical trial on COPD. This method may be expanded into other institutional and clinical settings. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Comparison study of in vivo dose response to laser-driven versus conventional electron beam.

    Science.gov (United States)

    Oppelt, Melanie; Baumann, Michael; Bergmann, Ralf; Beyreuther, Elke; Brüchner, Kerstin; Hartmann, Josefin; Karsch, Leonhard; Krause, Mechthild; Laschinsky, Lydia; Leßmann, Elisabeth; Nicolai, Maria; Reuter, Maria; Richter, Christian; Sävert, Alexander; Schnell, Michael; Schürer, Michael; Woithe, Julia; Kaluza, Malte; Pawelke, Jörg

    2015-05-01

    The long-term goal to integrate laser-based particle accelerators into radiotherapy clinics not only requires technological development of high-intensity lasers and new techniques for beam detection and dose delivery, but also characterization of the biological consequences of this new particle beam quality, i.e. ultra-short, ultra-intense pulses. In the present work, we describe successful in vivo experiments with laser-driven electron pulses by utilization of a small tumour model on the mouse ear for the human squamous cell carcinoma model FaDu. The already established in vitro irradiation technology at the laser system JETI was further enhanced for 3D tumour irradiation in vivo in terms of beam transport, beam monitoring, dose delivery and dosimetry in order to precisely apply a prescribed dose to each tumour in full-scale radiobiological experiments. Tumour growth delay was determined after irradiation with doses of 3 and 6 Gy by laser-accelerated electrons. Reference irradiation was performed with continuous electron beams at a clinical linear accelerator in order to both validate the dedicated dosimetry employed for laser-accelerated JETI electrons and above all review the biological results. No significant difference in radiation-induced tumour growth delay was revealed for the two investigated electron beams. These data provide evidence that the ultra-high dose rate generated by laser acceleration does not impact the biological effectiveness of the particles.

  3. Electron microscopy methods in studies of cultural heritage sites

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A. L., E-mail: a.vasiliev56@gmail.com; Kovalchuk, M. V.; Yatsishina, E. B. [National Research Centre “Kurchatov Institute” (Russian Federation)

    2016-11-15

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient “nanotechnologies”; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  4. Electron microscopy methods in studies of cultural heritage sites

    International Nuclear Information System (INIS)

    Vasiliev, A. L.; Kovalchuk, M. V.; Yatsishina, E. B.

    2016-01-01

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient “nanotechnologies”; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  5. Worldwide Protein Data Bank validation information: usage and trends.

    Science.gov (United States)

    Smart, Oliver S; Horský, Vladimír; Gore, Swanand; Svobodová Vařeková, Radka; Bendová, Veronika; Kleywegt, Gerard J; Velankar, Sameer

    2018-03-01

    Realising the importance of assessing the quality of the biomolecular structures deposited in the Protein Data Bank (PDB), the Worldwide Protein Data Bank (wwPDB) partners established Validation Task Forces to obtain advice on the methods and standards to be used to validate structures determined by X-ray crystallography, nuclear magnetic resonance spectroscopy and three-dimensional electron cryo-microscopy. The resulting wwPDB validation pipeline is an integral part of the wwPDB OneDep deposition, biocuration and validation system. The wwPDB Validation Service webserver (https://validate.wwpdb.org) can be used to perform checks prior to deposition. Here, it is shown how validation metrics can be combined to produce an overall score that allows the ranking of macromolecular structures and domains in search results. The ValTrends DB database provides users with a convenient way to access and analyse validation information and other properties of X-ray crystal structures in the PDB, including investigating trends in and correlations between different structure properties and validation metrics.

  6. Optimization and validation of the protocol used to analyze the taste of traditional Chinese medicines using an electronic tongue.

    Science.gov (United States)

    Li, Xuelin; Gao, Xiaojie; Liu, Ruixin; Wang, Junming; Wu, Zidan; Zhang, Lu; Li, Huiling; Gui, Xinjing; Kang, Bingya; Shi, Junhan

    2016-11-01

    Tools to define the active ingredients and flavors of Traditional Chinese Medicines (TCMs) are limited by long analysis times, complex sample preparation and a lack of multiplexed analysis. The aim of the present study was to optimize and validate an electronic tongue (E-tongue) methodology to analyze the bitterness of TCMs. To test the protocol, 35 different TCM concoctions were measured using an E-tongue, and seven replicate measurements of each sample were taken to evaluate reproducibility and precision. E-tongue sensor information was identified and classified using analysis approaches including least squares support vector machine (LS-SVM), support vector machine (SVM), discriminant analysis (DA) and partial least squares (PLS). A benefit of this analytical protocol was that the analysis of a single sample took <15 min for all seven sensors. The results identified that the LS-SVM approach provided the best bitterness classification accuracy (binary classification accuracy, 100%; ternary classification accuracy, 89.66%). The E-tongue protocol developed showed good reproducibility and high precision within a 6 h measurement cycle. To the best of our knowledge, this is the first study of an E-tongue being applied to assay the bitterness of TCMs. This approach could be applied in the classification of the taste of TCMs, and serve important roles in other fields, including foods and beverages.

  7. Early studies of placental ultrastructure by electron microscopy

    DEFF Research Database (Denmark)

    Carter, A M; Enders, A C

    2016-01-01

    many other scientists to Washington University in St. Louis. Work on human placental ultrastructure was initiated at Cambridge and Kyoto whilst domestic animals were initially studied by Björkman in Stockholm and electron micrographs of bat placenta were published by Wimsatt of Cornell University......BACKGROUND: Transmission electron microscopy (TEM) was first applied to study placental ultrastructure in the 1950's. We review those early studies and mention the scientists that employed or encouraged the use of TEM. FINDINGS: Among the pioneers Edward W. Dempsey was a key figure who attracted...

  8. Studies on keV and eV electrons in solids

    International Nuclear Information System (INIS)

    Schou, J.

    1979-10-01

    The interaction between keV or eV electrons and solids was studied. The results presented mostly concern problems in connection with electron irradiation of solids, but to some extent they also include ion-induced secondary electron emission. The experiments were mainly performed on solidified gases using 1 - 3 keV electrons. The projected range of electrons was determined in solid hydrogen, deuterium and nitrogen. The true secondary electron emission coefficient and the electron reflection coefficient of solid hydrogen, deuterium and nitrogen were measured. The escape depth of the true secondary electrons in nitrogen was determined. The angular dependence of both the reflection coefficient and the true secondary electron emission coefficient of solid hydrogen and deuterium was investigated. Both ion- and electron-induced secondary electron emission were treated theoretically on the basis of ionization cascade theory. (Auth.)

  9. Sci-Thur AM: YIS – 04: Stopping power-to-Cherenkov power ratios and beam quality specification for clinical Cherenkov emission dosimetry of electrons: beam-specific effects and experimental validation

    Energy Technology Data Exchange (ETDEWEB)

    Zlateva, Yana; Seuntjens, Jan; El Naqa, Issam [McGill University, Cedars Cancer Centre, University of Michigan (United States)

    2016-08-15

    Purpose: To advance towards clinical Cherenkov emission (CE)-based dosimetry by investigating beam-specific effects on Monte Carlo-calculated electron-beam stopping power-to-CE power ratios (SCRs), addressing electron beam quality specification in terms of CE, and validating simulations with measurements. Methods: The EGSnrc user code SPRRZnrc, used to calculate Spencer-Attix stopping-power ratios, was modified to instead calculate SCRs. SCRs were calculated for 6- to 22-MeV clinical electron beams from Varian TrueBeam, Clinac 21EX, and Clinac 2100C/D accelerators. Experiments were performed with a 20-MeV electron beam from a Varian TrueBeam accelerator, using a diffraction grating spectrometer with optical fiber input and a cooled back-illuminated CCD. A fluorophore was dissolved in the water to remove CE signal anisotropy. Results: It was found that angular spread of the incident beam has little effect on the SCR (≤ 0.3% at d{sub max}), while both the electron spectrum and photon contamination increase the SCR at shallow depths and decrease it at large depths. A universal data fit of R{sub 50} in terms of C{sub 50} (50% CE depth) revealed a strong linear dependence (R{sup 2} > 0.9999). The SCR was fit with a Burns-type equation (R{sup 2} = 0.9974, NRMSD = 0.5%). Below-threshold incident radiation was found to have minimal effect on beam quality specification (< 0.1%). Experiments and simulations were in good agreement. Conclusions: Our findings confirm the feasibility of the proposed CE dosimetry method, contingent on computation of SCRs from additional accelerators and on further experimental validation. This work constitutes an important step towards clinical high-resolution out-of-beam CE dosimetry.

  10. A Validation Study of the Impression Replica Technique.

    Science.gov (United States)

    Segerström, Sofia; Wiking-Lima de Faria, Johanna; Braian, Michael; Ameri, Arman; Ahlgren, Camilla

    2018-04-17

    To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry. © 2018 by the American College of Prosthodontists.

  11. Contribution to the study of electron paramagnetic resonance and relaxation

    International Nuclear Information System (INIS)

    Theobald, Jean-Gerard

    1962-01-01

    This research thesis reports an experimental work which comprises the development of a very practical and very sensitive electron paramagnetic resonance spectrometer, and the use of this equipment for the study of irradiated substances and carbons. By studying electronic resonance signals by fast modulation of the magnetic field, the author studied phenomena of quick passage in electronic resonance, and showed that the study of these phenomena requires observation systems with a particularly large bandwidth. He reports the measurement of the line width of packs of spins of inhomogeneous lines by two different methods [fr

  12. Electron spectroscopic study of electronic and morphological modifications of the WSe2 surface induced by Rb adsorption

    International Nuclear Information System (INIS)

    Buck, Jens

    2010-01-01

    The rubidium-covered surface of the semiconducting transition metal dichalcogenide tungsten diselenide (WSe 2 ) is examined using photoelectron spectroscopy (PES) and photoemission electron microscopy (PEEM). Adsorbed Rb is known to induce a variety of effects in this system concerning electronic, structural, and mechanical properties. In this work, the surface potential created by charge transfer upon Rb deposition is examined in thermal equilibrium (band bending) and stationary non-equilibrium (surface photovoltage (SPV) effect), which is induced by the absorption of light. It is shown that combined measurements and numerical simulations of the SPV effect as a function of the photon flux can be exploited for the estimation of many material parameters of the system, especially of the unoccupied adsorbate state. Issues of extending a conventional photoelectron spectrometer setup by a secondary light source will be discussed in the context of simulations and calibration measurements. The customization of an existing theoretical model of the SPV effect for the WSe 2 : Rb system is introduced, and a comprehensive validation of the obtained predictions is given in the context of experimental data. In addition, the self-organized formation of Rb domains at room temperature was examined by application of spatially resolved XPS spectroscopy using the PEEM setup at the end station of beamline UE49/PGMa at the BESSY II synchrotron facility. From the obtained results, the arrangement of Rb in surface lattices can be concluded. Furthermore, an X-Ray absorption study of self-organized nanostructure networks, aiming at the chemical characterization, is presented. Based on the interpretation of the examined structures as tension-induced cracks, a statistical approach to analyzing large-scale features was pursued. First accordance with the predictions made by a primitive, mechanical model of crack creation developed here gives gives some evidence for the validity of the proposed

  13. Trade-related Electronic Commerce Issues in the OECD

    Directory of Open Access Journals (Sweden)

    Chang-In Yoon

    1998-12-01

    Full Text Available The trade committee of Organization for Economic Cooperation and Development (OECD has begun the study of the trade related to electronic commerce since 1997. The scale of the study on one hand has avoided the fact of copy and duplication of WTO and its organizational principles, on the other hand it has played a supplementary and supportive function. At present, digital-related product, such as computers, software and travel is the key point to the trade which resorts to electronic commerce. It is predicted that this trend will go on. The study on electronic commerce could be summed up into three main components: First, according to the phase of the trade, it could be divided into advertisement, purchase, delivery and payment. Second, issues on electronic commerce in the international trade; such as the issue that leads to the unfairness and non-neutrality of the searching engine in international service trade. Besides, domain name, trademarks and the issue of middleman which exist at the moment in the electronic commerce are activated and will also be discussed. Third, issues of the trade policy related to the electronic commerce. For instance, the kernel principles which support the multi-trade regulation, including transparency, indiscrimination, anti-dumping, flexible trade, government arrangement, tariff and competition policy and so on. Under this background, we should explore way in formulating hypotheses with preconceived issues, validating the electronic commerce trade on the spot, actualizing the study on the application of electronic commerce coming with the GATS regulation, seeking the countermeasure in the future trade policy, such as benefit policy to the electronic commerce department and electronic commerce strategy approach of certain enterprises, etc.

  14. Attainment of Electron Beam Suitable for Medium Energy Electron Cooling

    International Nuclear Information System (INIS)

    Seletskiy, Sergey M.; Rochester U.

    2005-01-01

    Electron cooling of charged particle beams is a well-established technique at electron energies of up to 300 keV. However, up to the present time the advance of electron cooling to the MeV-range energies has remained a purely theoretical possibility. The electron cooling project at Fermilab has recently demonstrated the first cooling of 8.9 GeV/c antiprotons in the Recycler ring, and therefore, has proved the validity of the idea of relativistic electron cooling. The Recycler Electron Cooler (REC) is the key component of the Tevatron Run II luminosity upgrade project. Its performance depends critically on the quality of electron beam. A stable electron beam of 4.3 MeV carrying 0.5 A of DC current is required. The beam suitable for the Recycler Electron Cooler must have an angular spread not exceeding 200 (micro)rad. The full-scale prototype of the REC was designed, built and tested at Fermilab in the Wideband laboratory to study the feasibility of attaining the high-quality electron beam. In this thesis I describe various aspects of development of the Fermilab electron cooling system, and the techniques used to obtain the electron beam suitable for the cooling process. In particular I emphasize those aspects of the work for which I was principally responsible. Chapter 1 is an introduction where I describe briefly the theory and the history of electron cooling, and derive the requirements to the quality of electron beam and requirements to the basic parameters of the Recycler Electron Cooler. Chapter 2 is devoted to the theoretical consideration of the motion of electrons in the cooling section, description of the cooling section and of the measurement of the magnetic fields. In Chapter 3 I consider different factors that increase the effective electron angle in the cooling section and suggest certain algorithms for the suppression of parasitic angles. Chapter 4 is devoted to the measurements of the energy of the electron beam. In the concluding Chapter 5 I review

  15. Optical studies of polarized-electron-noble-gas collisions

    International Nuclear Information System (INIS)

    Gay, T.I.; Furst, J.E.; Geesmann, H.; Khakoo, M.A.; Madison, D.H.; Wijayaratna, W.M.K.P.; Bartschat, K.

    1992-01-01

    We have measured the Stoke's parameters of light emitted following impact excitation of He and Xe by transversely-polarized electrons. For He, the 2 3 S-3 3 P, 389 nm transition was studied in an effort to systematically develop a highly accurate optical electron polarimeter. The 6 3 P 2 -6 3 D 3 , 882 nm transition in Xe was used to assess the importance of spin-dependent forces on the continuum electron for this target. We attempted (and failed) to made the first optical observations of Mott scattering. (Author)

  16. High energy electron multibeam diffraction and imaging

    International Nuclear Information System (INIS)

    Bourret, Alain.

    1980-04-01

    The different theories of dynamical scattering of electrons are firstly reviewed with special reference to their basis and the validity of the different approximations. Then after a short description of the different experimental set ups, structural analysis and the investigation of the optical potential by means of high energy electrons will be surveyed

  17. An Italian multicentre validation study of the coma recovery scale-revised.

    Science.gov (United States)

    Estraneo, A; Moretta, P; De Tanti, A; Gatta, G; Giacino, J T; Trojano, L

    2015-10-01

    Rate of misdiagnosis of disorders of consciousness (DoC) can be reduced by employing validated clinical diagnostic tools, such as the Coma Recovery Scale-Revised (CRS-R). An Italian version of the CRS-R has been recently developed, but its applicability across different clinical settings, and its concurrent validity and diagnostic sensitivity have not been estimated yet. To perform a multicentre validation study of the Italian version of the Coma Recovery Scale-Revised (CRS-R). Analysis of inter-rater reliability, concurrent validity and diagnostic sensitivity of the scale. One Intensive Care Unit, 8 Post-acute rehabilitation centres and 2 Long-term facilities Twenty-seven professionals (physicians, N.=11; psychologists, N.=5; physiotherapists, N.=3; speech therapists, N.=6; nurses, N.=2) from 11 Italian Centres. CRS-R and Disability Rating Scale (DRS) applied to 122 patients with clinical diagnosis of Vegetative State (VS) or Minimally Conscious State (MCS). CRS-R has good-to-excellent inter-rater reliability for all subscales, particularly for the communication subscale. The Italian version of the CRS-R showed a high sensitivity and specificity in detecting MCS with reference to clinical consensus diagnosis. The CRS-R showed good concurrent validity with the Disability Rating Scale, which had very low specificity with reference to clinical consensus diagnosis. The Italian version of the CRS-R is a valid scale for use from the sub-acute to chronic stages of DoC. It can be administered reliably by all members of the rehabilitation team with different specialties, levels of experience and settings. The present study promote use of the Italian version of the CRS-R to improve diagnosis of DoC patients, and plan tailored rehabilitation treatment.

  18. Secondary electrons monitor for continuous electron energy measurements in UHF linac

    International Nuclear Information System (INIS)

    Zimek, Zbigniew; Bulka, Sylwester; Mirkowski, Jacek; Roman, Karol

    2001-01-01

    Continuous energy measurements have now became obligatory in accelerator facilities devoted to radiation sterilization process. This is one of several accelerator parameters like dose rate, beam current, bean scan parameters, conveyer speed which must be recorded as it is a required condition of accelerator validation procedure. Electron energy measurements are rather simple in direct DC accelerator, where the applied DC voltage is directly related to electron energy. High frequency linacs are not offering such opportunity in electron energy measurements. The analyzing electromagnet is applied in some accelerators but that method can be used only in off line mode before or after irradiation process. The typical solution is to apply the non direct method related to control and measurements certain accelerator parameters like beam current and microwave energy pulse power. The continuous evaluation of electron energy can be performed on the base of calculation and result comparison with calibration curve

  19. Studies on electron transfer reactions of Keggin-type mixed ...

    Indian Academy of Sciences (India)

    Administrator

    (PV2) in aqueous phosphate buffer of pH 6 at ambient temperature. Electrochemical and optical studies show that the stoichiometry of the reaction is 1: 2 (NADH : HPA). EPR and optical studies show that HPA act as one electron acceptor and the products of electron transfer reactions are one elec- tron reduced heteropoly ...

  20. Can relaxation interventions reduce anxiety in patients receiving radiotherapy? outcomes and study validity

    International Nuclear Information System (INIS)

    Elith, C.A.; Perkins, B.A.; Johnson, L.S.; Skelly, M.H.; Dempsey, S.

    2001-01-01

    This study piloted the use of three relaxation interventions in an attempt to reduce levels of anxiety in patients who are immobilised for radiotherapy treatment of head and neck cancers, as well as trying to validate the study methodology. In addition to receiving normal radiation therapy treatment, 14 patients were assigned to either a control group not receiving the relaxation intervention or one of three validated relaxation intervention techniques; music therapy, aromatherapy or guided imagery. Patients in the intervention groups underwent the relaxation technique daily for the first seven days of treatment. On days 1, 3, 5 and 7 of treatment patients were required to complete the State Anxiety Inventory survey. While caution should be taken in accepting the results due to the small numbers of patients involved in the study and the non-randomised assignment of patients within the study, the results of the study demonstrate a clinically significant reduction in anxiety levels in each of the three relaxation interventions compared to the control group. The study demonstrated good study validity due to the ease of implementation, the unambiguous results generated, and the use of already validated anxiety intersections and measurement tools. Copyright (2001) Australian Institute of Radiography

  1. Instrument for assessing mobile technology acceptability in diabetes self-management: a validation and reliability study.

    Science.gov (United States)

    Frandes, Mirela; Deiac, Anca V; Timar, Bogdan; Lungeanu, Diana

    2017-01-01

    Nowadays, mobile technologies are part of everyday life, but the lack of instruments to assess their acceptability for the management of chronic diseases makes their actual adoption for this purpose slow. The objective of this study was to develop a survey instrument for assessing patients' attitude toward and intention to use mobile technology for diabetes mellitus (DM) self-management, as well as to identify sociodemographic characteristics and quality of life factors that affect them. We first conducted the documentation and instrument design phases, which were subsequently followed by the pilot study and instrument validation. Afterward, the instrument was administered 103 patients (median age: 37 years; range: 18-65 years) diagnosed with type 1 or type 2 DM, who accepted to participate in the study. The reliability and construct validity were assessed by computing Cronbach's alpha and using factor analysis, respectively. The instrument included statements about the actual use of electronic devices for DM management, interaction between patient and physician, attitude toward using mobile technology, and quality of life evaluation. Cronbach's alpha was 0.9 for attitude toward using mobile technology and 0.97 for attitude toward using mobile device applications for DM self-management. Younger patients (Spearman's ρ =-0.429; P higher education level (Kendall's τ =0.51; P mobile assistive applications for DM control. Moreover, patients with a higher quality of life presented a significantly more positive attitude toward using modern technology (Spearman's ρ =0.466; P mobile technology for DM self-management. Additionally, we found that even if most of the patients showed positive attitude toward mobile applications, only a moderate level of intention to indeed use them was observed. Moreover, the study indicated that barriers were truthfulness and easiness to use.

  2. The electron-atom ionization problem

    International Nuclear Information System (INIS)

    McCarthy, I.E.

    1995-02-01

    Methods of calculating electron-atom ionization as a three-body problem with Coulomb boundary conditions are considered. In the absence of a fully-valid computational method for a time-independent experiment the approximation is made that the incident electron experiences a screened potential. Approximations involving a final state that obeys the three-body Coulomb boundary condition are compared with the distorted-wave Born approximation and the convergent close-coupling method. 24 refs., 6 figs

  3. Basic School Skills Inventory-3: Validity and Reliability Study

    Science.gov (United States)

    Yildiz, F. Ülkü; Çagdas, Aysel; Kayili, Gökhan

    2017-01-01

    The purpose of this study is to perform the validity-reliability analysis of the three subtests of Basic School Skills Inventory 3--Mathematics, Classroom Behavior and Daily Life skills--and do its adaptation for four to six year-old Turkish children. The sample of the study included 595 four to six year-old Turkish children attending public and…

  4. A Validation Study of the Adolescent Dissociative Experiences Scale

    Science.gov (United States)

    Keck Seeley, Susan. M.; Perosa, Sandra, L.; Perosa, Linda, M.

    2004-01-01

    Objective: The purpose of this study was to further the validation process of the Adolescent Dissociative Experiences Scale (A-DES). In this study, a 6-item Likert response format with descriptors was used when responding to the A-DES rather than the 11-item response format used in the original A-DES. Method: The internal reliability and construct…

  5. Validity and Reliability of Accelerometers in Patients With COPD: A SYSTEMATIC REVIEW.

    Science.gov (United States)

    Gore, Shweta; Blackwood, Jennifer; Guyette, Mary; Alsalaheen, Bara

    2018-05-01

    Reduced physical activity is associated with poor prognosis in chronic obstructive pulmonary disease (COPD). Accelerometers have greatly improved quantification of physical activity by providing information on step counts, body positions, energy expenditure, and magnitude of force. The purpose of this systematic review was to compare the validity and reliability of accelerometers used in patients with COPD. An electronic database search of MEDLINE and CINAHL was performed. Study quality was assessed with the Strengthening the Reporting of Observational Studies in Epidemiology checklist while methodological quality was assessed using the modified Quality Appraisal Tool for Reliability Studies. The search yielded 5392 studies; 25 met inclusion criteria. The SenseWear Pro armband reported high criterion validity under controlled conditions (r = 0.75-0.93) and high reliability (ICC = 0.84-0.86) for step counts. The DynaPort MiniMod demonstrated highest concurrent validity for step count using both video and manual methods. Validity of the SenseWear Pro armband varied between studies especially in free-living conditions, slower walking speeds, and with addition of weights during gait. A high degree of variability was found in the outcomes used and statistical analyses performed between studies, indicating a need for further studies to measure reliability and validity of accelerometers in COPD. The SenseWear Pro armband is the most commonly used accelerometer in COPD, but measurement properties are limited by gait speed variability and assistive device use. DynaPort MiniMod and Stepwatch accelerometers demonstrated high validity in patients with COPD but lack reliability data.

  6. Injection Drug Use Quality of Life scale (IDUQOL: A validation study

    Directory of Open Access Journals (Sweden)

    Palepu Anita

    2005-07-01

    Full Text Available Abstract Background Existing measures of injection drug users' quality of life have focused primarily on health and health-related factors. Clearly, however, quality of life among injection drug users is impacted by a range of unique cultural, socioeconomic, medical, and geographic factors that must also be considered in any measure. The Injection Drug User Quality of Life (IDUQOL scale was designed to capture the unique and individual circumstances that determine quality of life among injection drug users. The overall purpose of the present study was to examine the validity of inferences made from the IDUQOL by examining the (a dimensionality, (b reliability of scores, (c criterion-related validity evidence, and (d both convergent and discriminant validity evidence. Methods An exploratory factor analysis using principal axis factoring in SPSS 12.0 was conducted to determine whether the use of a total score on the IDUQOL was advisable. Reliability of scores from the IDUQOL was obtained using internal consistency and one-week test-retest reliability estimates. Criterion-related validity evidence was gathered using variables such as stability of housing, sex trade involvement, high-risk injection behaviours, involvement in treatment programs, emergency treatment or overdose over the previous six months, hospitalization and emergency treatment over the subsequent six month period post data collection. Convergent and discriminant validity evidence was gathered using measures of life satisfaction, self-esteem, and social desirability. Results The sample consisted of 241 injection drug users ranging in age from 19 to 61 years. Factor analysis supports the use of a total score. Both internal consistency (alpha = .88 and one-week test-retest reliability (r = .78 for IDUQOL total scores were good. Criterion-related, convergent, and discriminant validity evidence supports the interpretation of IDUQOL total scores as measuring a construct consistent with

  7. Method validation for strobilurin fungicides in cereals and fruit

    DEFF Research Database (Denmark)

    Christensen, Hanne Bjerre; Granby, Kit

    2001-01-01

    Strobilurins are a new class of fungicides that are active against a broad spectrum of fungi. In the present work a GC method for analysis of strobilurin fungicides was validated. The method was based on extraction with ethyl acetate/cyclohexane, clean-up by gel permeation chromatography (GPC......) and determination of the content by gas chromatography (GC) with electron capture (EC-), nitrogen/phosphorous (NP-), and mass spectrometric (MS-) detection. Three strobilurins, azoxystrobin, kresoxim-methyl and trifloxystrobin were validated on three matrices, wheat, apple and grapes. The validation was based...

  8. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    Science.gov (United States)

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. study of the effects of ionization on medicinal plants and validation of an analysis method adapted by electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Ben Khedim, Meriem

    2011-01-01

    The results of EPR and UV-Vis Spectroscopy studies on dry medicinal herbs of fenugreek, fennel, pollen and marjoram; before and after Gamma irradiation by Cobalt 60 source at doses from 3 to 50 kGy are reported and expressed as DPPH radical scavenging ability of each Herb's extract and as EPR intensity signal of each Herb's powder. Before irradiation, all samples exhibit one weak singlet EPR line with a g-factor at 2.004 2 .005 attributed to a quinone radical. Irradiation induced a significant increase in signal intensity relative to the free radicals without any change in spectral pattern. This increase is proportional to the absorbed dose and to the content of free radicals. Up to the optimal dose (19kGy); decay is shown with exceptions for 30, 35 or 40 kGy according the studied herb. The stability of the obtained EPR signal of irradiated samples was studied over a storage period of 90 days after radiation process and the results showed a significant decrease of free radicals signal intensity until their stability. All the EPR measurements were performed after the analytical method by EPR spectroscopy's validation.

  10. Electronic Versus Manual Data Processing: Evaluating the Use of Electronic Health Records in Out-of-Hospital Clinical Research

    Science.gov (United States)

    Newgard, Craig D.; Zive, Dana; Jui, Jonathan; Weathers, Cody; Daya, Mohamud

    2011-01-01

    Objectives To compare case ascertainment, agreement, validity, and missing values for clinical research data obtained, processed, and linked electronically from electronic health records (EHR), compared to “manual” data processing and record abstraction in a cohort of out-ofhospital trauma patients. Methods This was a secondary analysis of two sets of data collected for a prospective, population-based, out-of-hospital trauma cohort evaluated by 10 emergency medical services (EMS) agencies transporting to 16 hospitals, from January 1, 2006 through October 2, 2007. Eighteen clinical, operational, procedural, and outcome variables were collected and processed separately and independently using two parallel data processing strategies, by personnel blinded to patients in the other group. The electronic approach included electronic health record data exports from EMS agencies, reformatting and probabilistic linkage to outcomes from local trauma registries and state discharge databases. The manual data processing approach included chart matching, data abstraction, and data entry by a trained abstractor. Descriptive statistics, measures of agreement, and validity were used to compare the two approaches to data processing. Results During the 21-month period, 418 patients underwent both data processing methods and formed the primary cohort. Agreement was good to excellent (kappa 0.76 to 0.97; intraclass correlation coefficient 0.49 to 0.97), with exact agreement in 67% to 99% of cases, and a median difference of zero for all continuous and ordinal variables. The proportions of missing out-of-hospital values were similar between the two approaches, although electronic processing generated more missing outcomes (87 out of 418, 21%, 95% CI = 17% to 25%) than the manual approach (11 out of 418, 3%, 95% CI = 1% to 5%). Case ascertainment of eligible injured patients was greater using electronic methods (n = 3,008) compared to manual methods (n = 629). Conclusions In this

  11. A validation study of the Brief Irrational Thoughts Inventory

    NARCIS (Netherlands)

    Hoogsteder, L.M.; Wissink, I.B.; Stams, G.J.J.M.; van Horn, J.E.; Hendriks, J.

    2014-01-01

    This study examines the reliability and validity of the "Brief Irrational Thoughts Inventory" (BITI) in a sample of 256 justice-involved youths. The BITI is a questionnaire used to determine the nature and severity of irrational thoughts related to aggressive (externalizing), sub-assertive

  12. Protection of electronic circuits from overvoltages

    CERN Document Server

    Standler, Ronald B

    1989-01-01

    Practical rules and strategies designed to protect electronic systems from damage by transient overvoltages include symptoms and threats, remedies, protective devices and their applications, and validation of protective measures. 1989 edition.

  13. Penning ionization processes studied by electron spectroscopy

    International Nuclear Information System (INIS)

    Yencha, A.J.

    1978-01-01

    The technique of measuring the kinetic energy of electrons ejected from atomic or molecular species as a result of collisional energy transfer between a metastable excited rare gas atom and an atom or molecule is known as Penning ionization spectroscopy. Like the analogous photoionization process of photoelectron spectroscopy, a considerable amount of information has been gained about the ionization potentials of numerous molecular systems. It is, in fact, through the combined analyses of photoelectron and Penning electron spectra that affords a probe of the particle-particle interactions that occur in the Penning process. In this paper a short survey of the phenomenon of Penning ionization, as studied by electron spectroscopy, will be presented as it pertains to the ionization processes of simple molecules by metastable excited atoms. (author)

  14. Designing Interactive Electronic Module in Chemistry Lessons

    Science.gov (United States)

    Irwansyah, F. S.; Lubab, I.; Farida, I.; Ramdhani, M. A.

    2017-09-01

    This research aims to design electronic module (e-module) oriented to the development of students’ chemical literacy on the solution colligative properties material. This research undergoes some stages including concept analysis, discourse analysis, storyboard design, design development, product packaging, validation, and feasibility test. Overall, this research undertakes three main stages, namely, Define (in the form of preliminary studies); Design (designing e-module); Develop (including validation and model trial). The concept presentation and visualization used in this e-module is oriented to chemical literacy skills. The presentation order carries aspects of scientific context, process, content, and attitude. Chemists and multi media experts have done the validation to test the initial quality of the products and give a feedback for the product improvement. The feasibility test results stated that the content presentation and display are valid and feasible to be used with the value of 85.77% and 87.94%. These values indicate that this e-module oriented to students’ chemical literacy skills for the solution colligative properties material is feasible to be used.

  15. The Clinical Impression of Severity Index for Parkinson's Disease: international validation study.

    Science.gov (United States)

    Martínez-Martín, Pablo; Rodríguez-Blázquez, Carmen; Forjaz, Maria João; de Pedro, Jesús

    2009-01-30

    This study sought to provide further information about the psychometric properties of the Clinical Impression of Severity Index for Parkinson's Disease (CISI-PD), in a large, international, cross-culturally diverse sample. Six hundred and fourteen patients with PD participated in the study. Apart from the CISI-PD, assessments were based on Hoehn & Yahr (HY) staging, the Scales for Outcomes in PD-Motor (SCOPA-M), -Cognition (SCOPA-COG) and -Psychosocial (SCOPA-PS), the Cumulative Illness Rating Scale-Geriatrics, and the Hospital Anxiety and Depression Scale. The total CISI-PD score displayed no floor or ceiling effects. Internal consistency was 0.81, the test-retest intraclass correlation coefficient was 0.84, and item homogeneity was 0.52. Exploratory and confirmatory factor analysis (CFI = 0.99, RMSEA = 0.07) confirmed CISI-PD's unifactorial structure. The CISI-PD showed adequate convergent validity with SCOPA-COG and SCOPA-M (r(S) = 0.46-0.85, respectively) and discriminative validity for HY stages and disease duration (P validation study, thus showing that the CISI-PD is a valid instrument to measure clinical impression of severity in PD. Its simplicity and easy application make it an attractive and useful tool for clinical practice and research.

  16. Spin dynamics of electrons in strong fields studied via bremsstrahlung from a polarized electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Tashenov, Stanislav [Royal Institute of Technology, Stockholm (Sweden); Stockholm University (Sweden); Physikalisches Institut, Universitaet Heidelberg (Germany); Baeck, Torbjoern; Cederwall, Bo; Khaplanov, Anton; Schaessburger, Kai-Uwe [Royal Institute of Technology, Stockholm (Sweden); Barday, Roman; Enders, Joachim; Poltoratska, Yuliya [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Surzhykov, Andrey [Physikalisches Institut, Universitaet Heidelberg (Germany); GSI, Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2011-07-01

    Linear polarization of the photons emitted in the process of the atomic field electron bremsstrahlung has been studied at the newly developed 100 keV polarized electron source of TU Darmstadt. A correlation between the initial orientation of the electron spin and the degree and the angle of photon linear polarization has been measured for the first time. For this purpose a hard x-ray Compton polarimeter consisting of a segmented high purity germanium detector and an external passive photon scattering target have been applied. Linear polarization sensitive Compton and Rayleigh photon scattering distributions have been sampled by the segmented detector. The observed polarization correlation reveals a precession of the electron spin as it moves in the field of the nucleus. The full-relativistic calculations for the case of radiative recombination into a Rydberg series limit have been corroborated by the measurement. The results of this experiment suggest a new method for electron beam polarimetry.

  17. Fabrication and electronic transport studies of single nanocrystal systems

    Energy Technology Data Exchange (ETDEWEB)

    Klein, David Louis [Univ. of California, Berkeley, CA (United States). Dept. of Physics

    1997-05-01

    Semiconductor and metallic nanocrystals exhibit interesting electronic transport behavior as a result of electrostatic and quantum mechanical confinement effects. These effects can be studied to learn about the nature of electronic states in these systems. This thesis describes several techniques for the electronic study of nanocrystals. The primary focus is the development of novel methods to attach leads to prefabricated nanocrystals. This is because, while nanocrystals can be readily synthesized from a variety of materials with excellent size control, means to make electrical contact to these nanocrystals are limited. The first approach that will be described uses scanning probe microscopy to first image and then electrically probe surfaces. It is found that electronic investigations of nanocrystals by this technique are complicated by tip-sample interactions and environmental factors such as salvation and capillary forces. Next, an atomic force microscope technique for the catalytic patterning of the surface of a self assembled monolayer is described. In principle, this nano-fabrication technique can be used to create electronic devices which are based upon complex arrangements of nanocrystals. Finally, the fabrication and electrical characterization of a nanocrystal-based single electron transistor is presented. This device is fabricated using a hybrid scheme which combines electron beam lithography and wet chemistry to bind single nanocrystals in tunneling contact between closely spaced metallic leads. In these devices, both Au and CdSe nanocrystals show Coulomb blockade effects with characteristic energies of several tens of meV. Additional structure is seen the transport behavior of CdSe nanocrystals as a result of its electronic structure.

  18. Validation study of genetic biomarkers of response to TNF inhibitors in rheumatoid arthritis.

    Directory of Open Access Journals (Sweden)

    Rosario Lopez-Rodriguez

    Full Text Available Genetic biomarkers are sought to personalize treatment of patients with rheumatoid arthritis (RA, given their variable response to TNF inhibitors (TNFi. However, no genetic biomaker is yet sufficiently validated. Here, we report a validation study of 18 previously reported genetic biomarkers, including 11 from GWAS of response to TNFi. The validation was attempted in 581 patients with RA that had not been treated with biologic antirheumatic drugs previously. Their response to TNFi was evaluated at 3, 6 and 12 months in two ways: change in the DAS28 measure of disease activity, and according to the EULAR criteria for response to antirheumatic drugs. Association of these parameters with the genotypes, obtained by PCR amplification followed by single-base extension, was tested with regression analysis. These analyses were adjusted for baseline DAS28, sex, and the specific TNFi. However, none of the proposed biomarkers was validated, as none showed association with response to TNFi in our study, even at the time of assessment and with the outcome that showed the most significant result in previous studies. These negative results are notable because this was the first independent validation study for 12 of the biomarkers, and because they indicate that prudence is needed in the interpretation of the proposed biomarkers of response to TNFi even when they are supported by very low p values. The results also emphasize the requirement of independent replication for validation, and the need to search protocols that could increase reproducibility of the biomarkers of response to TNFi.

  19. Studies of runaway electrons via Cherenkov effect in tokamaks

    Science.gov (United States)

    Zebrowski, J.; Jakubowski, L.; Rabinski, M.; Sadowski, M. J.; Jakubowski, M. J.; Kwiatkowski, R.; Malinowski, K.; Mirowski, R.; Mlynar, J.; Ficker, O.; Weinzettl, V.; Causa, F.; COMPASS; FTU Teams

    2018-01-01

    The paper concerns measurements of runaway electrons (REs) which are generated during discharges in tokamaks. The control of REs is an important task in experimental studies within the ITER-physics program. The NCBJ team proposed to study REs by means of Cherenkov-type detectors several years ago. The Cherenkov radiation, induced by REs in appropriate radiators, makes it possible to identify fast electron beams and to determine their spatial- and temporal-characteristics. The results of recent experimental studies of REs, performed in two tokamaks - COMPASS in Prague and FTU in Frascati, are summarized and discussed in this paper. Examples of the electron-induced signals, as recorded at different experimental conditions and scenarios, are presented. Measurements performed with a three-channel Cherenkov-probe in COMPASS showed that the first fast electron peaks can be observed already during the current ramp-up phase. A strong dependence of RE-signals on the radial position of the Cherenkov probe was observed. The most distinct electron peaks were recorded during the plasma disruption. The Cherenkov signals confirmed the appearance of post-disruptive RE beams in circular-plasma discharges with massive Ar-puffing. During experiments at FTU a clear correlation between the Cherenkov detector signals and the rotation of magnetic islands was identified.

  20. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-11-01

    Full Text Available Reasoning with Inductive Argument Test:A Study of Validity and Reliability Objective: The aim of our study is to research reliability and validity and to evaluate the usability of Turkish version of Reasoning with Inductive Argument Test (RIAT in Turkish healty population. Method: 51 healty volunteers who work in Ankara Dıskapi Yildirim Beyazit Research and Training Hospital participated in this study. Reasoning with Inductive Argument Test (RIAT was translated into Turkish by three clinical good knowledge of English. Participants were given a sociodemographic data form, and RIAT were performed by clinicians. To test the reliability of the Turkish version of RIAT, Cronbach’s alpha coefficient was calculated and the halving method was used for the test. Results: The internal consistency of the Reasoning with Inductive Argument Test (RIAT items, Cronbach’s alpha internal consistency coefficient measurements of 0.73 was found to be statistically significant. Spearman-Brown coefficient that determines the reliability of the whole test r=0.74 was found. Kurtosis values of all the items was below 1.5 and the percentages in the second evaluation were mainly lower. At the same time, both change in belief between self produced RIAT options and given RIAT options (p=0.02, z=-2296 as well as changes in beliefs between related and unrelated items for Obsessive Compulsive Disorder (OCD difference (p=0.03, z=-2.199 were significant. Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population.

  1. Study of real space wave functions with electron energy loss spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Löffler, S.

    2013-07-01

    In this work, new methods to study the real space wave functions of electrons in a solid using transmission electron microscopy (TEM) and electron energy loss spectrometry (EELS) are presented. To this end, the theory of both elastic and inelastic electron scattering is treated in a density-matrix formalism. In the process, the central quantities of inelastic electron scattering - the mixed dynamic form factor (MDFF) and the double differential scattering cross section (DDSCS) - are introduced. In addition to the formal theory, several approximations and simplifications, as well as their respective validities, are discussed. Furthermore, a method for diagonalizing the mixed dynamic form factor is described, which allows calculating high resolution energy filtered TEM images with unprecedented accuracy. Subsequently, several applications of the aforementioned theory to real-world examples are presented. On the one hand, the example of Silicon serves to demonstrate how the radial wave functions in the bulk can be measured; the agreement with the theoretical predictions proves to be very good. On the other hand, the determination of the wave functions' azimuthal dependence is derived. It turns out that the symmetry of the system under investigation is crucial to the success of this endeavor. With the new techniques presented here, it will be possible to measure electronic properties with atomic resolution, which can be of great importance, particularly in material science. (author) [German] In der vorliegenden Arbeit werden neue Methoden vorgestellt, mit deren Hilfe Elektronenwellenfunktionen in Festkörpern mittels Transmissionselektronenmikroskopie (TEM) und Elektronenenergieverlustspektrometrie (EELS) direkt im Realraum vermessen werden können. Zu diesem Zweck wird sowohl die Theorie der elastischen Elektronenbeugung als auch die der inelastischen Elektronenstreuung im Dichtematrixformalismus dargestellt. Dabei werden die zentralen Größen der inelastischen

  2. Lumbar segmental instability: a criterion-related validity study of manual therapy assessment

    Directory of Open Access Journals (Sweden)

    Chapple Cathy

    2005-11-01

    Full Text Available Abstract Background Musculoskeletal physiotherapists routinely assess lumbar segmental motion during the clinical examination of a patient with low back pain. The validity of manual assessment of segmental motion has not, however, been adequately investigated. Methods In this prospective, multi-centre, pragmatic, diagnostic validity study, 138 consecutive patients with recurrent or chronic low back pain (R/CLBP were recruited. Physiotherapists with post-graduate training in manual therapy performed passive accessory intervertebral motion tests (PAIVMs and passive physiological intervertebral motion tests (PPIVMs. Consenting patients were referred for flexion-extension radiographs. Sagittal angular rotation and sagittal translation of each lumbar spinal motion segment was measured from these radiographs, and compared to a reference range derived from a study of 30 asymptomatic volunteers. Motion beyond two standard deviations from the reference mean was considered diagnostic of rotational lumbar segmental instability (LSI and translational LSI. Accuracy and validity of the clinical assessments were expressed using sensitivity, specificity, and likelihood ratio statistics with 95% confidence intervals (CI. Results Only translation LSI was found to be significantly associated with R/CLBP (p Conclusion This study provides the first evidence reporting the concurrent validity of manual tests for the detection of abnormal sagittal planar motion. PAIVMs and PPIVMs are highly specific, but not sensitive, for the detection of translation LSI. Likelihood ratios resulting from positive test results were only moderate. This research indicates that manual clinical examination procedures have moderate validity for detecting segmental motion abnormality.

  3. Electron-phonon interactions in correlated systems

    International Nuclear Information System (INIS)

    Wysokinski, K.I.

    1996-01-01

    There exist attempts to describe the superconducting mechanism operating in HTS as based on antiferromagnetic fluctuations. It is not our intention to dwell on the superconducting mechanism, even though this is very a important issue. The main aim is to discuss the problem of interplay between electron-phonon and electron-electron interactions in correlated systems. We believe such analysis can be of importance for various materials and not only HTS'S. We shall however mainly refer to experiments on this last class of superconductors. Severe complications are to be expected by studying the problem. As is well known electron correlations are very important in narrow band systems, where the relevant electronic scale E F is quite small. In those circumstances, the phonon energy scale ω D is of comparable magnitude, with the ratio ω D /E F of order 1 signalling a possible break down of the Migdal - Eliashberg description of the electron-phonon interaction in metals. Here we shall assume the validity of the Migdal-Eliashberg approximation and concentrate on the mutual influence of electron and phonon subsystems. In the next section we shall discuss experimental motivation for and theoretical work related to the present problem. Section 3 contains a brief discussion of our theory. It is a self-consistent theory a la Migdal with strong correlations treated with an auxiliary boson technique. We conclude with results and their discussion. (orig.)

  4. Modeling of Jupiter's electron an ion radiation belts

    International Nuclear Information System (INIS)

    Sicard, Angelica

    2004-01-01

    In the Fifties, James Van Allen showed the existence of regions of the terrestrial magnetosphere consisted of energetic particles, trapped by the magnetic field: the radiation belts. The radiation belts of the Earth were the subject of many modeling works and are studied since several years at the Departement Environnement Spatial (DESP) of ONERA. In 1998, the DESP decided to adapt the radiation belts model of the Earth, Salammbo, to radiation environment of Jupiter. A first thesis was thus carried out on the subject and a first radiation belts model of electrons of Jupiter was developed [Santos-Costa, 2001]. The aim of this second thesis is to develop a radiation belts model for protons and heavy ions. In order to validate the developed model, the comparisons between Salammbo results and observations are essential. However, the validation is difficult in the case of protons and heavy ions because in-situ measurements of the probes are very few and most of the time contaminated by very energetic electrons. To solve this problem, a very good model of electrons radiation belts is essential to confirm or cancel the contamination of protons and heavy ions measurements. Thus, in parallel to the development of the protons and heavy ions radiation belts model, the electrons models, already existing, has been improved. Then Salammbo results have been compared to the different observations available (in-situ measurements, radio-astronomical observations). The different comparisons show a very good agreement between Salammbo results and observations. (author) [fr

  5. GPM GROUND VALIDATION GCPEX SNOW MICROPHYSICS CASE STUDY V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation GCPEX Snow Microphysics Case Study characterizes the 3-D microphysical evolution and distribution of snow in context of the thermodynamic...

  6. Electron bremsstrahlung spectrum, 1--500 keV

    International Nuclear Information System (INIS)

    Lee, C.M.; Kissel, L.; Pratt, R.H.; Tseng, H.K.

    1976-01-01

    Numerical data are obtained for the electron bremsstrahlung energy spectrum resulting from incident electrons of kinetic energy 1--500 keV, under the assumption that the process is described as a single-electron transition in a relativistic self-consistent screened potential, using partial-wave expansions. Comparisons with simpler analytical approximations show that these are at best of qualitative validity in this energy range. Our data are used to construct more complete tables of the spectrum by interpolation

  7. Validating the Center for Epidemiological Studies Depression Scale for Children in Rwanda

    Science.gov (United States)

    Betancourt, Theresa; Scorza, Pamela; Meyers-Ohki, Sarah; Mushashi, Christina; Kayiteshonga, Yvonne; Binagwaho, Agnes; Stulac, Sara; Beardslee, William R.

    2012-01-01

    Objective: We assessed the validity of the Center for Epidemiological Studies Depression Scale for Children (CES-DC) as a screen for depression in Rwandan children and adolescents. Although the CES-DC is widely used for depression screening in high-income countries, its validity in low-income and culturally diverse settings, including sub-Saharan…

  8. Inter-professional electronic documents and child health: a study of persisting non-electronic communication in the use of electronic documents.

    Science.gov (United States)

    Saario, Sirpa; Hall, Christopher; Peckover, Sue

    2012-12-01

    Information and communication technologies are widely used in health and social care settings to replace previous means of record keeping, assessment and communication. Commentary on the strengths and weaknesses of such systems abound, thus it is useful to examine how they are used in practice. This article draws on findings from two separate studies, conducted between 2005 and 2007, which examined how child health and welfare professionals use electronic documents in Finland and England. Known respectively as Miranda and CAF, these systems are different in terms of structure and function but in their everyday use common features are identified, notably the continued use of and reliance on non-electronic means of communication. Based on interviews with professionals, three forms of non-electronic communication are described: alternative records, phone calls and letters, which facilitate the sharing of the electronic record. Finally, the electronic documents are further analysed as potential boundary objects which aim to create common understanding between sites and professionals. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Developments in quantitative electron probe microanalysis

    International Nuclear Information System (INIS)

    Tixier, R.

    1977-01-01

    A study of the range of validity of the formulae for corrections used with massive specimen analysis is made. The method used is original; we have shown that it was possible to use a property of invariability of corrected intensity ratios for standards. This invariance property provides a test for the self consistency of the theory. The theoretical and experimental conditions required for quantitative electron probe microanalysis of thin transmission electron microscope specimens are examined. The correction formulae for atomic number, absorption and fluorescence effects are calculated. Several examples of experimental results are given, relative to the quantitative analysis of intermetallic precipitates and carbides in steels. Advances in applications of electron probe instruments related to the use of computer and the present development of fully automated instruments are reviewed. The necessary statistics for measurements of X ray count data are studied. Estimation procedure and tests are developed. These methods are used to perform a statistical check of electron probe microanalysis measurements and to reject rogue values. An estimator of the confidence interval of the apparent concentration is derived. Formulae were also obtained to optimize the counting time in order to obtain the best precision in a minimum amount of time [fr

  10. Dislocation-mediated strain hardening in tungsten: Thermo-mechanical plasticity theory and experimental validation

    Science.gov (United States)

    Terentyev, Dmitry; Xiao, Xiazi; Dubinko, A.; Bakaeva, A.; Duan, Huiling

    2015-12-01

    A self-consistent thermo-mechanical model to study the strain-hardening behavior of polycrystalline tungsten was developed and validated by a dedicated experimental route. Dislocation-dislocation multiplication and storage, as well dislocation-grain boundary (GB) pinning were the major mechanisms underlying the evolution of plastic deformation, thus providing a link between the strain hardening behavior and material's microstructure. The microstructure of the polycrystalline tungsten samples has been thoroughly investigated by scanning and electron microscopy. The model was applied to compute stress-strain loading curves of commercial tungsten grades, in the as-received and as-annealed states, in the temperature range of 500-1000 °C. Fitting the model to the independent experimental results obtained using a single crystal and as-received polycrystalline tungsten, the model demonstrated its capability to predict the deformation behavior of as-annealed samples in a wide temperature range and applied strain. The relevance of the dislocation-mediated plasticity mechanisms used in the model have been validated using transmission electron microscopy examination of the samples deformed up to different amounts of strain. On the basis of the experimental validation, the limitations of the model are determined and discussed.

  11. Ion and electron swarm studies of relevance to plasma processing: positive ion-molecule and electron-molecule studies of SF6 and derivatives

    International Nuclear Information System (INIS)

    Atterbury, C.; Kennedy, R.A.; Critchley, A.D.J.; Mayhew, C.A.

    2002-01-01

    Many sequential and parallel chemical reactions involving charged species occur in a plasma. Data needed to model plasma's chemical and physical environment includes cross-section, rate coefficients, and product ion distribution of electron-molecule and ion-molecule processes. Such reactions are studied by our group away from the complexity of the plasma environment, with experimental techniques that allow us to concentrate on a single process, where usually only one or two species are involved. A molecule commonly used in plasma etching applications is SF 6 1,2 . We have performed a series of positive ion-molecule and electron attachment studies on SF 6 and related molecules, including SeF 6 , TeF 6 (i.e. XF 6 molecules), SF 5 CF 3 and SF 5 Cl (i.e. SF 5 X molecules) 3- (. The studies of ion reactions with and electron attachment to SF 6 and physically similar molecules are of value when seeking to understand the ion and electron chemistry occurring in SF 6 containing plasma. The result of these studies are presented in this poster. Ion-molecule reactions. Rate coefficients and ion product branching ratios have been determined with the Selected Ion Flow Tube (SIFT) at room temperature (300 K) for reactions of SF 5 X with the following twenty-two cations; Ne + , F + , Ar + , N 2 + , N + , CO + , CO 2 + , O + , N 2 O + , O 2 + , SF 4 + , CF 2 + , SF + , SF 2 + , NO 2 + , SF 5 + , NO + , CF + , CF 3 + , SF 3 + , and H 3 O + (listed in order of decreasing recombination energy). SF 2 + , NO 2 + , NO + , SF 3 + , and H 3 O + are found to be unreacted with both SF 5 CF 3 and SF 5 Cl. The majority of the other reactions proceed with rate coefficients that are close to the capture value. Those found to occur at rates significantly less than the capture mechanism value re the reactions of O 2 + , SF + , SF 5 + , and CF 3 + with SF 5 CF 3 , and SF 4 + and SF 5 + with SF 5 Cl. Several distinction processes are observed among the large number of reactions studied, including

  12. Theoretical study of lithium clusters by electronic stress tensor

    International Nuclear Information System (INIS)

    Ichikawa, Kazuhide; Nozaki, Hiroo; Komazawa, Naoya; Tachibana, Akitomo

    2012-01-01

    We study the electronic structure of small lithium clusters Li_n (n = 2 ∼ 8) using the electronic stress tensor. We find that the three eigenvalues of the electronic stress tensor of the Li clusters are negative and degenerate, just like the stress tensor of liquid. This leads us to propose that we may characterize a metallic bond in terms of the electronic stress tensor. Our proposal is that in addition to the negativity of the three eigenvalues of the electronic stress tensor, their degeneracy characterizes some aspects of the metallic nature of chemical bonding. To quantify the degree of degeneracy, we use the differential eigenvalues of the electronic stress tensor. By comparing the Li clusters and hydrocarbon molecules, we show that the sign of the largest eigenvalue and the differential eigenvalues could be useful indices to evaluate the metallicity or covalency of a chemical bond.

  13. External Validation Study of First Trimester Obstetric Prediction Models (Expect Study I): Research Protocol and Population Characteristics.

    Science.gov (United States)

    Meertens, Linda Jacqueline Elisabeth; Scheepers, Hubertina Cj; De Vries, Raymond G; Dirksen, Carmen D; Korstjens, Irene; Mulder, Antonius Lm; Nieuwenhuijze, Marianne J; Nijhuis, Jan G; Spaanderman, Marc Ea; Smits, Luc Jm

    2017-10-26

    A number of first-trimester prediction models addressing important obstetric outcomes have been published. However, most models have not been externally validated. External validation is essential before implementing a prediction model in clinical practice. The objective of this paper is to describe the design of a study to externally validate existing first trimester obstetric prediction models, based upon maternal characteristics and standard measurements (eg, blood pressure), for the risk of pre-eclampsia (PE), gestational diabetes mellitus (GDM), spontaneous preterm birth (PTB), small-for-gestational-age (SGA) infants, and large-for-gestational-age (LGA) infants among Dutch pregnant women (Expect Study I). The results of a pilot study on the feasibility and acceptability of the recruitment process and the comprehensibility of the Pregnancy Questionnaire 1 are also reported. A multicenter prospective cohort study was performed in The Netherlands between July 1, 2013 and December 31, 2015. First trimester obstetric prediction models were systematically selected from the literature. Predictor variables were measured by the Web-based Pregnancy Questionnaire 1 and pregnancy outcomes were established using the Postpartum Questionnaire 1 and medical records. Information about maternal health-related quality of life, costs, and satisfaction with Dutch obstetric care was collected from a subsample of women. A pilot study was carried out before the official start of inclusion. External validity of the models will be evaluated by assessing discrimination and calibration. Based on the pilot study, minor improvements were made to the recruitment process and online Pregnancy Questionnaire 1. The validation cohort consists of 2614 women. Data analysis of the external validation study is in progress. This study will offer insight into the generalizability of existing, non-invasive first trimester prediction models for various obstetric outcomes in a Dutch obstetric population

  14. Electron cloud studies for SIS-18 and for the FAIR synchrotrons

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Fedor; Weiland, Thomas [Technische Universitaet Darmstadt, Institut fuer Theorie Elektromagnetischer Felder (TEMF), Darmstadt (Germany); Boine-Frankenheim, Oliver [Gesellschaft fuer Schwerionenforschung (GSI) GmbH, Darmstadt (Germany)

    2010-07-01

    Electron clouds generated by residual gas ionization pose a potential threat to the stability of the circulating heavy ion beams in the existing SIS-18 synchrotron and in the projected SIS-100. The electrons can potentially accumulate in the space charge potential of the long bunches. As an extreme case we study the accumulation of electrons in a coasting beam under conditions relevant in the SIS-18. Previous studies of electron clouds in coasting beams used particle-in-cell (PIC) codes to describe the generation of the cloud and the interaction with the ion beam. PIC beams exhibit much larger fluctuation amplitudes than real beams. The fluctuations heat the electrons. Therefore the obtained neutralization degree is strongly reduced, relative to a real beam. In our simulation model we add a Langevin term to the electron equation of motion in order to account for the heating process. The effect of natural beam fluctuations on the neutralization degree is studied. The modification of the beam response function as well as the stability limits in the presence of the electrons is discussed.

  15. Polarization Studies for the eRHIC Electron Storage Ring

    Energy Technology Data Exchange (ETDEWEB)

    Gianfelice-Wendt, Eliana [Fermilab; Tepikian, S. [Brookhaven

    2018-04-01

    A hadron/lepton collider with polarized beams has been under consideration by the scientific community since some years, in the U.S. and Europe. Among the various proposals, those by JLAB and BNL with polarized electron and proton beams are currently under closer study in the U.S. Experimenters call for the simultaneous storage of electron bunches with both spin helicity. In the BNL based Ring-Ring design, electrons are stored at top energy in a ring to be accommodated in the existing RHIC tunnel. The transversely polarized electron beam is injected into the storage ring at variable energies, between 5 and 18 GeV. Polarization is brought into the longitudinal direction at the IP by a couple of spin rotators. In this paper results of first studies of the attainable beam polarization level and lifetime in the storage ring at 18 GeV are presented.

  16. Advanced Electron Holography Applied to Electromagnetic Field Study in Materials Science.

    Science.gov (United States)

    Shindo, Daisuke; Tanigaki, Toshiaki; Park, Hyun Soon

    2017-07-01

    Advances and applications of electron holography to the study of electromagnetic fields in various functional materials are presented. In particular, the development of split-illumination electron holography, which introduces a biprism in the illumination system of a holography electron microscope, enables highly accurate observations of electromagnetic fields and the expansion of the observable area. First, the charge distributions on insulating materials were studied by using split-illumination electron holography and including a mask in the illumination system. Second, the three-dimensional spin configurations of skyrmion lattices in a helimagnet were visualized by using a high-voltage holography electron microscope. Third, the pinning of the magnetic flux lines in a high-temperature superconductor YBa 2 Cu 3 O 7-y was analyzed by combining electron holography and scanning ion microscopy. Finally, the dynamic accumulation and collective motions of electrons around insulating biomaterial surfaces were observed by utilizing the amplitude reconstruction processes of electron holography. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Validation study of the Japanese version of the Obsessive-Compulsive Drinking Scale.

    Science.gov (United States)

    Tatsuzawa, Yasutaka; Yoshimasu, Haruo; Moriyama, Yasushi; Furusawa, Teruyuki; Yoshino, Aihide

    2002-02-01

    The Obsessive-Compulsive Drinking Scale (OCDS) is a self-rating questionnaire that measures cognitive and behavioral aspects of craving for alcohol. The OCDS consists of two subscales: the obsessive thoughts of drinking subscale (OS) and the compulsive drinking subscale (CS). This study aims to validate the Japanese version of the OCDS. First, internal consistency and discriminant validity were evaluated. Second, a prospective longitudinal 3-month outcome study of 67 patients with alcohol dependence who participated in a relapse prevention program was designed to assess the concurrent and predictive validity of the OCDS. The OCDS demonstrated high internal consistency. The OS had high discriminant validity, while the CS did not. Twenty-three patients (34.3%) dropped out of treatment. These patients had significantly higher OS scores than those who completed the program. At 3 months, the relapse group had significantly higher OCDS scores than the no relapse group. Also, the OCDS score was higher in subjects who had early-onset alcohol dependence than late-onset dependence. The OCDS is useful for evaluating cognitive aspect of craving and predicts dropout and relapse.

  18. Investigating the role of electronic insurance on decreasing exporting charges risks

    Directory of Open Access Journals (Sweden)

    Farideh MosallaiZade

    2014-07-01

    Full Text Available Nowadays, the electronic insurance (EI is one the electronic services, which is used in most countries, and that is one effective factor in developing the exporting products and services. On the other hand, the incurrence industry and very especially EI represent their importance both domestically and internationally. One of the ways for transferring the exporting risks is to transfer the risks to the insurer. This paper examines the characteristics of EI and the effects of decreasing the exporting risk charges. The proposed study designs a questionnaire in the form of Likert scale, the validity of the questionnaire is validated by some the experts' viewpoints and the Cronbach' alpha is measure as 0.794. The results of applying Freedman test have disclosed that facilitating export activities was the most important factor followed by access to target export market information.

  19. Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron–electron interactions, application to graphene

    International Nuclear Information System (INIS)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-01-01

    Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron–electron (e–e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e–e interactions. This required adapting the treatment of e–e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

  20. Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron–electron interactions, application to graphene

    Energy Technology Data Exchange (ETDEWEB)

    Borowik, Piotr, E-mail: pborow@poczta.onet.pl [Warsaw University of Technology, Faculty of Physics, ul. Koszykowa 75, 00-662 Warszawa (Poland); Thobel, Jean-Luc, E-mail: jean-luc.thobel@iemn.univ-lille1.fr [Institut d' Electronique, de Microélectronique et de Nanotechnologies, UMR CNRS 8520, Université Lille 1, Avenue Poincaré, CS 60069, 59652 Villeneuve d' Ascq Cédex (France); Adamowicz, Leszek, E-mail: adamo@if.pw.edu.pl [Warsaw University of Technology, Faculty of Physics, ul. Koszykowa 75, 00-662 Warszawa (Poland)

    2017-07-15

    Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron–electron (e–e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e–e interactions. This required adapting the treatment of e–e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

  1. Electron emission and plasma generation in a modulator electron gun using ferroelectric cathode

    International Nuclear Information System (INIS)

    Chen Shutao; Zheng Shuxin; Zhu Ziqiu; Dong Xianlin; Tang Chuanxiang

    2006-01-01

    Strong electron emission and dense plasma generation have been observed in a modulator electron gun with a Ba 0.67 Sr 0.33 TiO 3 ferroelectric cathode. Parameter of the modulator electron gun and lifetime of the ferroelectric cathode were investigated. It was shown that electron emission from Ba 0.67 Sr 0.33 TiO 3 cathode with a positive triggering pulse is a sort of plasma emission. Electrons were emitted by the co-effect of surface plasma and non-compensated negative polarization charges at the surface of the ferroelectric. The element analyses of the graphite collector after emission process was performed to show the ingredient of the plasma consist of Ba, Ti and Cu heavy cations of the ceramic compound and electrode. It was demonstrated the validity of the Child-Langmuir law by introducing the decrease of vacuum gap and increase of emission area caused by the expansion of the surface plasma

  2. The birth satisfaction scale: Turkish adaptation, validation and reliability study

    Science.gov (United States)

    Cetin, Fatma Cosar; Sezer, Ayse; Merih, Yeliz Dogan

    2015-01-01

    OBJECTIVE: The objective of this study is to investigate the validity and the reliability of Birth Satisfaction Scale (BSS) and to adapt it into the Turkish language. This scale is used for measuring maternal satisfaction with birth in order to evaluate women’s birth perceptions. METHODS: In this study there were 150 women who attended to inpatient postpartum clinic. The participants filled in an information form and the BSS questionnaire forms. The properties of the scale were tested by conducting reliability and validation analyses. RESULTS: BSS entails 30 Likert-type questions. It was developed by Hollins Martin and Fleming. Total scale scores ranged between 30–150 points. Higher scores from the scale mean increases in birth satisfaction. Three overarching themes were identified in Scale: service provision (home assessment, birth environment, support, relationships with health care professionals); personal attributes (ability to cope during labour, feeling in control, childbirth preparation, relationship with baby); and stress experienced during labour (distress, obstetric injuries, receiving sufficient medical care, obstetric intervention, pain, prolonged labour and baby’s health). Cronbach’s alfa coefficient was 0.62. CONCLUSION: According to the present study, BSS entails 30 Likert-type questions and evaluates women’s birth perceptions. The Turkish version of BSS has been proven to be a valid and a reliable scale. PMID:28058355

  3. Electron spectroscopic study of electronic and morphological modifications of the WSe{sub 2} surface induced by Rb adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Jens

    2010-07-20

    The rubidium-covered surface of the semiconducting transition metal dichalcogenide tungsten diselenide (WSe{sub 2}) is examined using photoelectron spectroscopy (PES) and photoemission electron microscopy (PEEM). Adsorbed Rb is known to induce a variety of effects in this system concerning electronic, structural, and mechanical properties. In this work, the surface potential created by charge transfer upon Rb deposition is examined in thermal equilibrium (band bending) and stationary non-equilibrium (surface photovoltage (SPV) effect), which is induced by the absorption of light. It is shown that combined measurements and numerical simulations of the SPV effect as a function of the photon flux can be exploited for the estimation of many material parameters of the system, especially of the unoccupied adsorbate state. Issues of extending a conventional photoelectron spectrometer setup by a secondary light source will be discussed in the context of simulations and calibration measurements. The customization of an existing theoretical model of the SPV effect for the WSe{sub 2}: Rb system is introduced, and a comprehensive validation of the obtained predictions is given in the context of experimental data. In addition, the self-organized formation of Rb domains at room temperature was examined by application of spatially resolved XPS spectroscopy using the PEEM setup at the end station of beamline UE49/PGMa at the BESSY II synchrotron facility. From the obtained results, the arrangement of Rb in surface lattices can be concluded. Furthermore, an X-Ray absorption study of self-organized nanostructure networks, aiming at the chemical characterization, is presented. Based on the interpretation of the examined structures as tension-induced cracks, a statistical approach to analyzing large-scale features was pursued. First accordance with the predictions made by a primitive, mechanical model of crack creation developed here gives gives some evidence for the validity of the

  4. Electron-ion recombination study in argon at atmospheric pressure

    International Nuclear Information System (INIS)

    Kafrouni, Hanna.

    1979-01-01

    This study deals with a wall-stabilized arc burning in argon at atmospheric pressure. A transient mode is obtained using a fast thyristor connected to the electrodes, which short-circuits the discharge. By means of two wavelengths laser interferometry and spectroscopy measurements we have determined the temporal changes of the electron density, ground state atom density and excited atom density. We have shown that, when the electric field is suppressed, the electron temperature rapidly decreases to the gas temperature before changing electron and atom densities. This phenomenon is applied to determine the gas temperature and to evaluate the role played by ionization in electron density balance. The coefficients of ambipolar diffusion, ionization and recombination and an apparent recombination coefficient are determined versus electron temperature and compared with theoretical values [fr

  5. Experimental study of fast electron transport in dense plasmas

    International Nuclear Information System (INIS)

    Vaisseau, Xavier

    2014-01-01

    The framework of this PhD thesis is the inertial confinement fusion for energy production, in the context of the electron fast ignition scheme. The work consists in a characterization of the transport mechanisms of fast electrons, driven by intense laser pulses (10 19 - 10 20 W/cm 2 ) in both cold-solid and warm-dense matter. The first goal was to study the propagation of a fast electron beam, characterized by a current density ≥ 10 11 A/cm 2 , in aluminum targets initially heated close to the Fermi temperature by a counter-propagative planar shock. The planar compression geometry allowed us to discriminate the energy losses due to the resistive mechanisms from collisional ones by comparing solid and compressed targets of the same initial areal densities. We observed for the first time a significant increase of resistive energy losses in heated aluminum samples. The confrontation of the experimental data with the simulations, including a complete characterization of the electron source, of the target compression and of the fast electron transport, allowed us to study the time-evolution of the material resistivity. The estimated resistive electron stopping power in a warm-compressed target is of the same order as the collisional one. We studied the transport of the fast electrons generated in the interaction of a high-contrast laser pulse with a hollow copper cone, buried into a carbon layer, compressed by a counter-propagative planar shock. A X-ray imaging system allowed us to visualize the coupling of the laser pulse with the cone at different moments of the compression. This diagnostic, giving access to the fast electron spatial distribution, showed a fast electron generation in the entire volume of the cone for late times of compression, after shock breakout from the inner cone tip. For earlier times, the interaction at a high-contrast ensured that the source was contained within the cone tip, and the fast electron beam was collimated into the target depth by

  6. Organic High Electron Mobility Transistors Realized by 2D Electron Gas.

    Science.gov (United States)

    Zhang, Panlong; Wang, Haibo; Yan, Donghang

    2017-09-01

    A key breakthrough in inorganic modern electronics is the energy-band engineering that plays important role to improve device performance or develop novel functional devices. A typical application is high electron mobility transistors (HEMTs), which utilizes 2D electron gas (2DEG) as transport channel and exhibits very high electron mobility over traditional field-effect transistors (FETs). Recently, organic electronics have made very rapid progress and the band transport model is demonstrated to be more suitable for explaining carrier behavior in high-mobility crystalline organic materials. Therefore, there emerges a chance for applying energy-band engineering in organic semiconductors to tailor their optoelectronic properties. Here, the idea of energy-band engineering is introduced and a novel device configuration is constructed, i.e., using quantum well structures as active layers in organic FETs, to realize organic 2DEG. Under the control of gate voltage, electron carriers are accumulated and confined at quantized energy levels, and show efficient 2D transport. The electron mobility is up to 10 cm 2 V -1 s -1 , and the operation mechanisms of organic HEMTs are also argued. Our results demonstrate the validity of tailoring optoelectronic properties of organic semiconductors by energy-band engineering, offering a promising way for the step forward of organic electronics. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Visualizing and Validating Metadata Traceability within the CDISC Standards.

    Science.gov (United States)

    Hume, Sam; Sarnikar, Surendra; Becnel, Lauren; Bennett, Dorine

    2017-01-01

    The Food & Drug Administration has begun requiring that electronic submissions of regulated clinical studies utilize the Clinical Data Information Standards Consortium data standards. Within regulated clinical research, traceability is a requirement and indicates that the analysis results can be traced back to the original source data. Current solutions for clinical research data traceability are limited in terms of querying, validation and visualization capabilities. This paper describes (1) the development of metadata models to support computable traceability and traceability visualizations that are compatible with industry data standards for the regulated clinical research domain, (2) adaptation of graph traversal algorithms to make them capable of identifying traceability gaps and validating traceability across the clinical research data lifecycle, and (3) development of a traceability query capability for retrieval and visualization of traceability information.

  8. Electronic conductivity studies on oxyhalide glasses containing TMO

    Energy Technology Data Exchange (ETDEWEB)

    Vijayatha, D. [R& D Center, Bharatiar University, Coimbatore, Tamil Nadu (India); Department of Physics, Gurunanak Institute of Technology, Hyderabad -040 (India); Viswanatha, R. [Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560012 (India); Sujatha, B. [Department of Electronics and Communcation, MSRIT, Bangalore 560054 (India); Narayana Reddy, C., E-mail: nivetejareddy@gmail.com [Department of Physics, Sree Siddaganga College of Arts, Science and Commerce, Tumkur 572102 (India)

    2016-05-06

    Microwave-assisted synthesis is cleaner, more economical and much faster than conventional methods. The development of new routes for the synthesis of solid materials is an integral part of material science and technology. The electronic conductivity studies on xPbCl{sub 2} – 60 PbO – (40-x) V{sub 2}O{sub 5} (1 ≥ x ≤ 10) glass system has been carried out over a wide range of composition and temperature (300 K to 423 K). X-ray diffraction study confirms the amorphous nature of the samples. The Scanning electron microscopic studies reveal the formation of cluster like morphology in PbCl{sub 2} containing glasses. The d.c conductivity exhibits Arrhenius behaviour and increases with V{sub 2}O{sub 5} concentration. Analysis of the results is interpreted in view Austin-Mott’s small polaron model of electron transport. Activation energies calculated using regression analysis exhibit composition dependent trend and the variation is explained in view of the structure of lead-vanadate glass.

  9. Electronic nicotine delivery system (electronic cigarette) awareness, use, reactions and beliefs: a systematic review

    Science.gov (United States)

    Pepper, Jessica K; Brewer, Noel T

    2015-01-01

    Objective We sought to systematically review the literature on electronic nicotine delivery systems (ENDS, also called electronic cigarettes) awareness, use, reactions and beliefs. Data sources We searched five databases for articles published between 2006 and 1 July 2013 that contained variations of the phrases ‘electronic cigarette’, ‘e-cigarette’ and ‘electronic nicotine delivery’. Study selection Of the 244 abstracts identified, we excluded articles not published in English, articles unrelated to ENDS, dissertation abstracts and articles without original data on prespecified outcomes. Data extraction Two reviewers coded each article for ENDS awareness, use, reactions and beliefs. Data synthesis 49 studies met inclusion criteria. ENDS awareness increased from 16% to 58% from 2009 to 2011, and use increased from 1% to 6%. The majority of users were current or former smokers. Many users found ENDS satisfying, and some engaged in dual use of ENDS and other tobacco. No longitudinal studies examined whether ENDS serve as ‘gateways’ to future tobacco use. Common reasons for using ENDS were quitting smoking and using a product that is healthier than cigarettes. Self-reported survey data and prospective trials suggest that ENDS might help cigarette smokers quit, but no randomised controlled trials with probability samples compared ENDS with other cessation tools. Some individuals used ENDS to avoid smoking restrictions. Conclusions ENDS use is expanding rapidly despite experts’ concerns about safety, dual use and possible ‘gateway’ effects. More research is needed on effective public health messages, perceived health risks, validity of self-reports of smoking cessation and the use of different kinds of ENDS. PMID:24259045

  10. Robustness study in SSNTD method validation: indoor radon quality

    Energy Technology Data Exchange (ETDEWEB)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L., E-mail: danilacdias@gmail.com [Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2017-07-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  11. Robustness study in SSNTD method validation: indoor radon quality

    International Nuclear Information System (INIS)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L.

    2017-01-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  12. Experimental studies of electron capture

    International Nuclear Information System (INIS)

    Pedersen, E.H.

    1983-01-01

    This thesis discusses the main results of recent experimental studies of electron capture in asymmetric collisions. Most of the results have been published, but the thesis also contains yet unpublished data, or data presented only in unrefereed conference proceedings. The thesis aims at giving a coherent discussion of the understanding of the experimental results, based first on simple qualitative considerations and subsequently on quantitative comparisons with the best theoretical calculations currently available. (Auth.)

  13. Density functional theory of electron transfer beyond the Born-Oppenheimer approximation: Case study of LiF

    Science.gov (United States)

    Li, Chen; Requist, Ryan; Gross, E. K. U.

    2018-02-01

    We perform model calculations for a stretched LiF molecule, demonstrating that nonadiabatic charge transfer effects can be accurately and seamlessly described within a density functional framework. In alkali halides like LiF, there is an abrupt change in the ground state electronic distribution due to an electron transfer at a critical bond length R = Rc, where an avoided crossing of the lowest adiabatic potential energy surfaces calls the validity of the Born-Oppenheimer approximation into doubt. Modeling the R-dependent electronic structure of LiF within a two-site Hubbard model, we find that nonadiabatic electron-nuclear coupling produces a sizable elongation of the critical Rc by 0.5 bohr. This effect is very accurately captured by a simple and rigorously derived correction, with an M-1 prefactor, to the exchange-correlation potential in density functional theory, M = reduced nuclear mass. Since this nonadiabatic term depends on gradients of the nuclear wave function and conditional electronic density, ∇Rχ(R) and ∇Rn(r, R), it couples the Kohn-Sham equations at neighboring R points. Motivated by an observed localization of nonadiabatic effects in nuclear configuration space, we propose a local conditional density approximation—an approximation that reduces the search for nonadiabatic density functionals to the search for a single function y(n).

  14. Theoretical and experimental studies of runaway electrons in the TEXTOR tokamak

    International Nuclear Information System (INIS)

    Abdullaev, S.S.; Finken, K.H.; Wongrach, K.; Willi, O.

    2016-01-01

    Theoretical and experimental studies of runaway electrons in tokamaks and their mitigations, particularly the recent studies performed by a group of the Heinrich-Heine University Duesseldorf in collaboration with the Institute of Energy and Climate Research of the Research Centre (Forschungszentrum) of Juelich are reviewed. The main topics focus on (i) runaway generation mechanisms, (ii) runaway orbits in equilibrium plasma, (iii) transport in stochastic magnetic fields, (iv) diagnostics and investigations of transport of runaway electron and their losses in low density discharges (v) runaway electrons during plasma disruptions, and (vi) runaway mitigation methods. The development of runaway diagnostics enables the measurement of runaway electrons in both the centre and edge of the plasma. The diagnostics provide an absolute runaway energy resolved measurement, the radial decay length of runaway electrons and, the structure and dynamics of runaway electron beams. The new mechanism of runaway electron formation during plasma disruptions is discussed.

  15. Theoretical and experimental studies of runaway electrons in the TEXTOR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Abdullaev, S.S.; Finken, K.H.; Wongrach, K.; Willi, O.

    2016-07-01

    Theoretical and experimental studies of runaway electrons in tokamaks and their mitigations, particularly the recent studies performed by a group of the Heinrich-Heine University Duesseldorf in collaboration with the Institute of Energy and Climate Research of the Research Centre (Forschungszentrum) of Juelich are reviewed. The main topics focus on (i) runaway generation mechanisms, (ii) runaway orbits in equilibrium plasma, (iii) transport in stochastic magnetic fields, (iv) diagnostics and investigations of transport of runaway electron and their losses in low density discharges (v) runaway electrons during plasma disruptions, and (vi) runaway mitigation methods. The development of runaway diagnostics enables the measurement of runaway electrons in both the centre and edge of the plasma. The diagnostics provide an absolute runaway energy resolved measurement, the radial decay length of runaway electrons and, the structure and dynamics of runaway electron beams. The new mechanism of runaway electron formation during plasma disruptions is discussed.

  16. Validation study of a drift-wave turbulence model for CSDX linear plasma device

    Science.gov (United States)

    Vaezi, P.; Holland, C.; Thakur, S. C.; Tynan, G. R.

    2017-09-01

    A validation study of self-regulating drift-wave turbulence/zonal flow dynamics in the Controlled Shear Decorrelation Experiment linear plasma device using Langmuir probe synthetic diagnostics is presented in this paper. We use a set of nonlocal 3D equations, which evolve density, vorticity, and electron temperature fluctuations, and include proper sheath boundary conditions. Nonlinear simulations of these equations are carried out using BOUndary Turbulence (BOUT++) framework. To identify the dominant parametric dependencies of the model, a linear growth rate sensitivity analysis is performed using input parameter uncertainties, which are taken from the experimental measurements. For the direct comparison of nonlinear simulation results to experiment, we use synthetic Langmuir probe diagnostics to generate a set of synthetic ion saturation current and floating potential fluctuations. In addition, comparisons of azimuthal velocities determined via time-delay estimation, and nonlinear energy transfer are shown. We observe a significant improvement of model-experiment agreement relative to the previous 2D simulations. An essential component of this improved agreement is found to be the effect of electron temperature fluctuations on floating potential measurements, which introduces clear amplitude and phase shifts relative to the plasma potential fluctuations in synthetically measured quantities, where the simulations capture the experimental measurements in the core of plasma. However, the simulations overpredict the fluctuation levels at larger radii. Moreover, systematic simulation scans show that the self-generated E × B zonal flows profile is very sensitive to the steepening of density equilibrium profile. This suggests that evolving both fluctuations and equilibrium profiles, along with the inclusion of modest axial variation of radial profiles in the model are needed for further improvement of simulation results against the experimental measurements.

  17. Validation of general job satisfaction in the Korean Labor and Income Panel Study.

    Science.gov (United States)

    Park, Shin Goo; Hwang, Sang Hee

    2017-01-01

    The purpose of this study is to assess the validity and reliability of general job satisfaction (JS) in the Korean Labor and Income Panel Study (KLIPS). We used the data from the 17th wave (2014) of the nationwide KLIPS, which selected a representative panel sample of Korean households and individuals aged 15 or older residing in urban areas. We included in this study 7679 employed subjects (4529 males and 3150 females). The general JS instrument consisted of five items rated on a scale from 1 (strongly disagree) to 5 (strongly agree). The general JS reliability was assessed using the corrected item-total correlation and Cronbach's alpha coefficient. The validity of general JS was assessed using confirmatory factor analysis (CFA) and Pearson's correlation. The corrected item-total correlations ranged from 0.736 to 0.837. Therefore, no items were removed. Cronbach's alpha for general JS was 0.925, indicating excellent internal consistency. The CFA of the general JS model showed a good fit. Pearson's correlation coefficients for convergent validity showed moderate or strong correlations. The results obtained in our study confirm the validity and reliability of general JS.

  18. Study of electron beam production by a plasma focus

    International Nuclear Information System (INIS)

    Smith, J.R.; Luo, C.M.; Rhee, M.J.; Schneider, R.F.

    1983-01-01

    A preliminary investigation of the electron beam produced by a plasma focus device using a current charged transmission line is described. Electron beam currents as high as 10 kA were measured. Interaction of the extracted beam and the filling gas was studied using open shutter photography

  19. Comparative study of electron conduction in azulene and naphthalene

    Indian Academy of Sciences (India)

    Wintec

    tional or electronic devices. Recent advances in experi- mental techniques have allowed ... stimulates us to study the electronic conduction in azulene molecule and to compare that with its isomer, naphthalene. ..... ernment of India, for funding and (SD) acknowledges CSIR,. Government of India, for a research fellowship.

  20. Parkinsons Disease-related Circulating microRNA Biomarkers——a Validation Study

    Directory of Open Access Journals (Sweden)

    David Petillo

    2015-02-01

    Full Text Available Parkinson's disease (PD is the second most common neurodegenerative disease. One of the major challenges in studying this progressive neurological disorder is to identify and develop biomarkers for early detection. Recently, several blood-based microRNA (miRNA biomarkers for PD have been reported. However, follow-up studies with new, independent cohorts have been rare. Previously, we identified a panel of four circulating miRNA biomarkers for PD (miR-1826, miR-450b-3p, miR-505, and miR-626 with biomarker performance of 91% sensitivity and 100% specificity. However, the expression of miR-450b-3p could not be detected in a new, independent validation set. In our current study, we improved the detection power by including a non-biased pre-amplification step in quantitative real-time PCR (qRT-PCR and reevaluated the biomarker performance. We found the panel of four PD-related miRNAs achieved the predictive power of 83% sensitivity and 75% specificity in our validation set. This is the first biomarker validation study of PD which showed reproducibility and robustness of plasma-based circulating miRNAs as molecular biomarkers and qRT-PCR as potential diagnostic assay.

  1. Sample size determination for disease prevalence studies with partially validated data.

    Science.gov (United States)

    Qiu, Shi-Fang; Poon, Wai-Yin; Tang, Man-Lai

    2016-02-01

    Disease prevalence is an important topic in medical research, and its study is based on data that are obtained by classifying subjects according to whether a disease has been contracted. Classification can be conducted with high-cost gold standard tests or low-cost screening tests, but the latter are subject to the misclassification of subjects. As a compromise between the two, many research studies use partially validated datasets in which all data points are classified by fallible tests, and some of the data points are validated in the sense that they are also classified by the completely accurate gold-standard test. In this article, we investigate the determination of sample sizes for disease prevalence studies with partially validated data. We use two approaches. The first is to find sample sizes that can achieve a pre-specified power of a statistical test at a chosen significance level, and the second is to find sample sizes that can control the width of a confidence interval with a pre-specified confidence level. Empirical studies have been conducted to demonstrate the performance of various testing procedures with the proposed sample sizes. The applicability of the proposed methods are illustrated by a real-data example. © The Author(s) 2012.

  2. Clinical prediction models for bronchopulmonary dysplasia: a systematic review and external validation study

    NARCIS (Netherlands)

    Onland, Wes; Debray, Thomas P.; Laughon, Matthew M.; Miedema, Martijn; Cools, Filip; Askie, Lisa M.; Asselin, Jeanette M.; Calvert, Sandra A.; Courtney, Sherry E.; Dani, Carlo; Durand, David J.; Marlow, Neil; Peacock, Janet L.; Pillow, J. Jane; Soll, Roger F.; Thome, Ulrich H.; Truffert, Patrick; Schreiber, Michael D.; van Reempts, Patrick; Vendettuoli, Valentina; Vento, Giovanni; van Kaam, Anton H.; Moons, Karel G.; Offringa, Martin

    2013-01-01

    Bronchopulmonary dysplasia (BPD) is a common complication of preterm birth. Very different models using clinical parameters at an early postnatal age to predict BPD have been developed with little extensive quantitative validation. The objective of this study is to review and validate clinical

  3. Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study

    Directory of Open Access Journals (Sweden)

    van de Water Tanja

    2017-01-01

    Full Text Available Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT, fifteen elite (25 ± 4 years and nine non-elite (24 ± 4 years Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6% and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%. Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p 0.05. Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p 0.05. In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players’ performance.

  4. Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study.

    Science.gov (United States)

    van de Water, Tanja; Huijgen, Barbara; Faber, Irene; Elferink-Gemser, Marije

    2017-01-01

    Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT), fifteen elite (25 ± 4 years) and nine non-elite (24 ± 4 years) Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6%) and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%). Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p 0.05). Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p badminton-specific reaction time, nor both components of inhibitory control (p > 0.05). In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players' performance.

  5. Assessing validity of observational intervention studies – the Benchmarking Controlled Trials

    Science.gov (United States)

    Malmivaara, Antti

    2016-01-01

    Abstract Background: Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. Aims: To create and pilot test a checklist for appraising methodological validity of a BCT. Methods: The checklist was created by extracting the most essential elements from the comprehensive set of criteria in the previous paper on BCTs. Also checklists and scientific papers on observational studies and respective systematic reviews were utilized. Ten BCTs published in the Lancet and in the New England Journal of Medicine were used to assess feasibility of the created checklist. Results: The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. Conclusions: The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. However, the piloted checklist should be validated in further studies.Key messagesBenchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations.This paper presents a checklist for appraising methodological validity of BCTs and pilot-tests the checklist with ten BCTs published in leading medical journals. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies.The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. PMID:27238631

  6. Positron annihilation and electron spin resonance studies of defects in electron-irradiated 3C-SiC

    International Nuclear Information System (INIS)

    Itoh, Hisayoshi; Yoshikawa, Masahito; Tanigawa, Shoichiro; Nashiyama, Isamu; Misawa, Shunji; Okumura, Hajime; Yoshida, Sadafumi.

    1992-01-01

    Defects induced by 1 MeV electron-irradiation in cubic silicon carbide (3C-SiC) epitaxially grown by chemical vapor deposition have been studied with positron annihilation and electron spin resonance (ESR). Doppler broadened energy spectra of annihilation γ-rays obtained by using variable-energy positron beams showed the formation of vacancy-type defects in 3C-SiC by the electron-irradiation. An ESR spectrum labeled Tl, which has an isotropic g-value of 2.0029 ± 0.001, was observed in electron-irradiated 3C-SiC. The Tl spectrum is interpreted by hyperfine interactions of paramagnetic electrons with 13 C at four carbon sites and 29 Si at twelve silicon sites, indicating that the Tl center arises from a point defect at a silicon site. Both the results can be accounted for by the introduction of isolated Si vacancies by the irradiation. (author)

  7. The validity of the diagnosis of inflammatory arthritis in a large population-based primary care database.

    NARCIS (Netherlands)

    Nielen, M.M.J.; Ursum, J.; Schellevis, F.G.; Korevaar, J.C.

    2013-01-01

    Background: Large population-based databases based on electronic medical records (EMRs) of patients in primary care are a useful data source to investigate morbidity and health care utilization. Diagnoses recorded in EMRs are doctor-defined, but their validity can be disputed. In this study we

  8. Worst-case study for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagents: Methodology validation of total organic carbon

    International Nuclear Information System (INIS)

    Porto, Luciana Valeria Ferrari Machado

    2015-01-01

    Radiopharmaceuticals are defined as pharmaceutical preparations containing a radionuclide in their composition, mostly intravenously administered, and therefore compliance with the principles of Good Manufacturing Practices (GMP) is essential and indispensable. Cleaning validation is a requirement of the current GMP, and consists of documented evidence, which demonstrates that the cleaning procedures are able to remove residues to pre-determined acceptance levels, ensuring that no cross contamination occurs. A simplification of cleaning processes validation is accepted, and consists in choosing a product, called 'worst case', to represent the cleaning processes of all equipment of the same production area. One of the steps of cleaning validation is the establishment and validation of the analytical method to quantify the residue. The aim of this study was to establish the worst case for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagent (LR) for labeling with 99m Tc, evaluate the use of Total Organic Carbon (TOC) content as indicator of equipment cleaning used in the LR manufacture, validate the method of Non-Purgeable Organic Carbon (NPOC), and perform recovery tests with the product chosen as worst case. Worst case product's choice was based on the calculation of an index called 'Worst Case Index' (WCI), using information about drug solubility, difficulty of cleaning the equipment and occupancy rate of the products in line production. The products indicated 'worst case' was the LR MIBI-TEC. The method validation assays were performed using carbon analyser model TOC-Vwp coupled to an autosampler model ASI-V, both from Shimadzu®, controlled by TOC Control-V software. It was used the direct method for NPOC quantification. The parameters evaluated in the validation method were: system suitability, robustness, linearity, detection limit (DL) and quantification limit (QL), precision

  9. Discriminant validity study of Achilles enthesis ultrasound.

    Science.gov (United States)

    Expósito Molinero, María Rosa; de Miguel Mendieta, Eugenio

    2016-01-01

    We want to know if the ultrasound examination of the Achilles tendon in spondyloarthritis is different compared to other rheumatic diseases. We studied 97 patients divided into five groups: rheumatoid arthritis, spondyloarthritis, gout, chondrocalcinosis and osteoarthritis, exploring six elementary lesions in 194 Achilles entheses examined. In our study the total index ultrasonographic Achilles is higher in spondyloarthritis with significant differences. The worst elementary spondyloarthritis lesions for discriminations against other pathologies were calcification. This study aims to demonstrate the discriminant validity of Achilles enthesitis observed by ultrasound in spondyloarthritis compared with other rheumatic diseases that may also have ultrasound abnormalities such enthesis level. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  10. Validity and Reliability of the Iranian Version of eHealth Literacy Scale

    Directory of Open Access Journals (Sweden)

    Soheila Bazm

    2016-06-01

    Full Text Available Abstract: Introduction:  The eHEALS is an 8-item measure of eHealth literacy developed to measure consumers’ combined knowledge, comfort, and perceived skills at finding, evaluating, and applying electronic health information to health problems. The current study aims to measure validity and reliability of the Iranian version of eHEALS questionnaire in a population context. Materials & Methods: A cross-sectional study was done on 525 youths people who has been chosen randomly in Iran, Yazd. We determined content validity, construct validity and predictive validity of the translated questionnaire. Principal components factor analysis was used to determine the theoretical fit of the measures with the data. The internal consistency of the translated questionnaire was evaluated using Cronbach α coefficient. The results were analyzed in SPSSv16. Results: The principal component analysis (PCA produced a single factor solution (70.48% of variance with factor loading ranging from 0.723 to 0.862. The internal consistency of the scale was sufficient (alpha=0.88 , P<0.001 and the test-retest coefficients for the items were reliable (r= 0.96, P<0.001. Discussion: The results of the study showed that the items in the translated questionnaire were equivalent to the original scale .The version of the eHEALS questionnaire showed both good reliability and validity for the screening of eHealth literacy of Iranian people.

  11. Electron Impact Excitation-Ionization of Molecules

    Science.gov (United States)

    Ali, Esam Abobakr A.

    In the last few decades, the study of atomic collisions by electron-impact has made significant advances. The most difficult case to study is electron impact ionization of molecules for which many approximations have to be made and the validity of these approximations can only be checked by comparing with experiment. In this thesis, I have examined the Molecular three-body distorted wave (M3DW) or Molecular four-body distorted wave (M4DW) approximations for electron-impact ionization. These models use a fully quantum mechanical approach where all particles are treated quantum mechanically and the post collision interaction (PCI) is treated to all orders of perturbation. These electron impact ionization collisions play central roles in the physics and chemistry of upper atmosphere, biofuel, the operation of discharges and lasers, radiation induced damage in biological material like damage to DNA by secondary electrons, and plasma etching processes. For the M3DW model, I will present results for electron impact single ionization of small molecules such as Water, Ethane, and Carbon Dioxide and the much larger molecules Tetrahydrofuran, phenol, furfural, 1-4 Benzoquinone. I will also present results for the four-body problem in which there are two target electrons involved in the collision. M4DW results will be presented for dissociative excitation-ionization of orientated D2. I will show that M4DW calculations using a variational wave function for the ground state that included s- and p- orbital states give better agreement to the experimental measurements than a ground state approximated as a product of two 1s-type Dyson orbitals.

  12. The Validity of Graduate Management Admission Test Scores: A Summary of Studies Conducted from 1997 to 2004

    Science.gov (United States)

    Talento-Miller, Eileen; Rudner, Lawrence M.

    2008-01-01

    The validity of Graduate Management Admission Test (GMAT) scores is examined by summarizing 273 studies conducted between 1997 and 2004. Each of the studies was conducted through the Validity Study Service of the test sponsor and contained identical variables and statistical methods. Validity coefficients from each of the studies were corrected…

  13. A study on construction, validation and determination of normalization of adolescents depression scale

    Directory of Open Access Journals (Sweden)

    Khadijeh Babakhani

    2014-01-01

    Full Text Available This paper presents an empirical investigation to construct, to validate and to determine normalization factors associated with adolescents depression scale. The study is performed among 750 randomly selected guided and high school students, 364 male and 386 female, who live in city of Zanjan, Iran. Validity of Beck Depression Inventory (BDI, Validity of Simpson-Angus Scale (SAS and divergence validity of the Coopersmith self- esteem coefficients are 0.72, 0.37 and -0.71, respectively. Result suggests that adolescents’ depression test is a reliable and valid tool for assessing depression, with utility in both research and clinical settings, counseling centers. In addition, the results of correlation test indicate there are some meaningful differences between depression levels of female and male students. In fact, our survey indicates that female students have more depression than male students do (F-value = 33.06, Sig. = 0.000. In addition, there are some meaningful differences between depression levels in various educational levels (F-value = 8.59, Sig. = 0.000. However, the study does not find sufficient evidence to believe there is any meaningful correlation between educational backgrounds and gender.

  14. Design and Construction of Experiment for Direct Electron Irradiation of Uranyl Sulfate Solution: Bubble Formation and Thermal Hydraulics Studies

    Energy Technology Data Exchange (ETDEWEB)

    Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, Roman [Argonne National Lab. (ANL), Argonne, IL (United States); Makarashvili, Vakho [Argonne National Lab. (ANL), Argonne, IL (United States); Heltemes, Thad [Argonne National Lab. (ANL), Argonne, IL (United States); Sun, Zaijing [Argonne National Lab. (ANL), Argonne, IL (United States); Wardle, Kent E. [Argonne National Lab. (ANL), Argonne, IL (United States); Bailey, James [Argonne National Lab. (ANL), Argonne, IL (United States); Quigley, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States); Stepinski, Dominique [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-10-01

    Argonne is assisting SHINE Medical Technologies in developing SHINE, a system for producing fission-product 99Mo using a D/T-accelerator to produce fission in a non-critical target solution of aqueous uranyl sulfate. We have developed an experimental setup for studying thermal-hydraulics and bubble formation in the uranyl sulfate solution to simulate conditions expected in the SHINE target solution during irradiation. A direct electron beam from the linac accelerator will be used to irradiate a 20 L solution (sector of the solution vessel). Because the solution will undergo radiolytic decomposition, we will be able to study bubble formation and dynamics and effects of convection and temperature on bubble behavior. These experiments will serve as a verification/ validation tool for the thermal-hydraulic model. Utilization of the direct electron beam for irradiation allows homogeneous heating of a large solution volume and simplifies observation of the bubble dynamics simultaneously with thermal-hydraulic data collection, which will complement data collected during operation of the miniSHINE experiment. Irradiation will be conducted using a 30-40 MeV electron beam from the high-power linac accelerator. The total electron-beam power will be 20 kW, which will yield a power density on the order of 1 kW/L. The solution volume will be cooled on the front and back surfaces and central tube to mimic the geometry of the proposed SHINE solution vessel. Also, multiple thermocouples will be inserted into the solution vessel to map thermal profiles. The experimental design is now complete, and installation and testing are in progress.

  15. Structural studies of glasses by transmission electron microscopy and electron diffraction

    International Nuclear Information System (INIS)

    Kashchieva, E.P.

    1997-01-01

    The purpose of this work is to present information about the applications of transmission electron microscopy (TEM) and electron diffraction (ED) for structural investigations of glasses. TEM investigations have been carried out on some binary and on a large number of ternary borate-telluride systems where glass-forming oxides, oxides of transitional elements and modified oxides of elements from I, II and III groups in the periodic table, are used as third component. The large experimental data given by TEM method allows the fine classification of the micro-heterogeneities. A special case of micro-heterogeneous structure with technological origin occurs near the boundary between the 2 immiscible liquids obtained at macro-phase separation. TEM was also used for the direct observation of the glass structure and we have studied the nano-scale structure of borate glasses obtained at slow and fast cooling of the melts. The ED possesses advantages for analysis of amorphous thin films or micro-pastilles and it is a very useful technique for study in materials containing simultaneously light and heavy elements. A comparison between the possibilities of the 3 diffraction techniques (X-ray diffraction, neutron diffraction and ED) is presented

  16. Validation studies of the DOE-2 Building Energy Simulation Program. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, R.; Winkelmann, F.

    1998-06-01

    This report documents many of the validation studies (Table 1) of the DOE-2 building energy analysis simulation program that have taken place since 1981. Results for several versions of the program are presented with the most recent study conducted in 1996 on version DOE-2.1E and the most distant study conducted in 1981 on version DOE-1.3. This work is part of an effort related to continued development of DOE-2, particularly in its use as a simulation engine for new specialized versions of the program such as the recently released RESFEN 3.1. RESFEN 3.1 is a program specifically dealing with analyzing the energy performance of windows in residential buildings. The intent in providing the results of these validation studies is to give potential users of the program a high degree of confidence in the calculated results. Validation studies in which calculated simulation data is compared to measured data have been conducted throughout the development of the DOE-2 program. Discrepancies discovered during the course of such work has resulted in improvements in the simulation algorithms. Table 2 provides a listing of additions and modifications that have been made to various versions of the program since version DOE-2.1A. One of the most significant recent changes in the program occurred with version DOE-2.1E. An improved algorithm for calculating the outside surface film coefficient was implemented. In addition, integration of the WINDOW 4 program was accomplished resulting in improved ability in analyzing window energy performance. Validation and verification of a program as sophisticated as DOE-2 must necessarily be limited because of the approximations inherent in the program. For example, the most accurate model of the heat transfer processes in a building would include a three-dimensional analysis. To justify such detailed algorithmic procedures would correspondingly require detailed information describing the building and/or HVAC system and energy plant parameters

  17. Recent validation studies for two NRPB environmental transfer models

    International Nuclear Information System (INIS)

    Brown, J.; Simmonds, J.R.

    1991-01-01

    The National Radiological Protection Board (NRPB) developed a dynamic model for the transfer of radionuclides through terrestrial food chains some years ago. This model, now called FARMLAND, predicts both instantaneous and time integrals of concentration of radionuclides in a variety of foods. The model can be used to assess the consequences of both accidental and routine releases of radioactivity to the environment; and results can be obtained as a function of time. A number of validation studies have been carried out on FARMLAND. In these the model predictions have been compared with a variety of sets of environmental measurement data. Some of these studies will be outlined in the paper. A model to predict external radiation exposure from radioactivity deposited on different surfaces in the environment has also been developed at NRPB. This model, called EXPURT (EXPosure from Urban Radionuclide Transfer), can be used to predict radiation doses as a function of time following deposition in a variety of environments, ranging from rural to inner-city areas. This paper outlines validation studies and future extensions to be carried out on EXPURT. (12 refs., 4 figs.)

  18. Quench detection electronics testing protocol for SST-1 magnets

    International Nuclear Information System (INIS)

    Banaudha, Moni; Varmora, Pankaj; Parghi, Bhadresh; Prasad, Upendra

    2017-01-01

    Quench Detection (QD) system consisting 204 signal channels has been successfully installed and working well during plasma experiment of SST-1 Tokamak. QD system requires testing, validation and maintenance in every SST-1 campaign for better reliability and maintainability of the system. Standalone test of each channel of the system is essential for hard-ware validation. The standard Testing Protocol follow in every campaign which validate each section of QD electronics as well as voltage tap signal cables which are routed inside the cryostat and then extended outside of the SST-1 machine up-to the magnet control room. Fiber link for Quench signal transmission to the SST-1 magnet power supply is also test and validate before every plasma campaign. Precise instrument used as a dummy source of quench signal and for manual quench generation to test the each channel and Master Quench Logic. Each signal Integrated with the magnet DAQ system, signal observed at 1Hz and 50Hz configuration to validate the logging data, compare with actual and previous test data. This paper describes the testing protocol follow in every campaign to validate functionality of QD electronics, limitation of testing, test results and overall integration of the quench detection system for SST-1 magnet. (author)

  19. The EORTC information questionnaire, EORTC QLQ-INFO25. Validation study for Spanish patients.

    Science.gov (United States)

    Arraras, Juan Ignacio; Manterola, Ana; Hernández, Berta; Arias de la Vega, Fernando; Martínez, Maite; Vila, Meritxell; Eito, Clara; Vera, Ruth; Domínguez, Miguel Ángel

    2011-06-01

    The EORTC QLQ-INFO25 evaluates the information received by cancer patients. This study assesses the psychometric properties of the QLQ-INFO25 when applied to a sample of Spanish patients. A total of 169 patients with different cancers and stages of disease completed the EORTC QLQINFO25, the EORTC QLQ-C30 and the information scales of the inpatient satisfaction module EORTC IN-PATSAT32 on two occasions during the patients' treatment and follow- up period. Psychometric evaluation of the structure, reliability, validity and responsiveness to changes was conducted. Patient acceptability was assessed with a debriefing questionnaire. Multi-trait scaling confirmed the 4 multi-item scales (information about disease, medical tests, treatment and other services) and eight single items. All items met the standards for convergent validity and all except one met the standards of item discriminant validity. Internal consistency for all scales (α>0.70) and the whole questionnaire (α>0.90) was adequate in the three measurements, except information about the disease (0.67) and other services (0.68) in the first measurement, as was test-retest reliability (intraclass correlations >0.70). Correlations with related areas of IN-PATSAT32 (r>0.40) supported convergent validity. Divergent validity was confirmed through low correlations with EORTC QLQ-C30 scales (rinformation and satisfaction. One scale and an item showed changes over time. The EORTC QLQ-INFO 25 is a reliable and valid instrument when applied to a sample of Spanish cancer patients. These results are in line with those of the EORTC validation study.

  20. A new hybrid code (CHIEF) implementing the inertial electron fluid equation without approximation

    Science.gov (United States)

    Muñoz, P. A.; Jain, N.; Kilian, P.; Büchner, J.

    2018-03-01

    We present a new hybrid algorithm implemented in the code CHIEF (Code Hybrid with Inertial Electron Fluid) for simulations of electron-ion plasmas. The algorithm treats the ions kinetically, modeled by the Particle-in-Cell (PiC) method, and electrons as an inertial fluid, modeled by electron fluid equations without any of the approximations used in most of the other hybrid codes with an inertial electron fluid. This kind of code is appropriate to model a large variety of quasineutral plasma phenomena where the electron inertia and/or ion kinetic effects are relevant. We present here the governing equations of the model, how these are discretized and implemented numerically, as well as six test problems to validate our numerical approach. Our chosen test problems, where the electron inertia and ion kinetic effects play the essential role, are: 0) Excitation of parallel eigenmodes to check numerical convergence and stability, 1) parallel (to a background magnetic field) propagating electromagnetic waves, 2) perpendicular propagating electrostatic waves (ion Bernstein modes), 3) ion beam right-hand instability (resonant and non-resonant), 4) ion Landau damping, 5) ion firehose instability, and 6) 2D oblique ion firehose instability. Our results reproduce successfully the predictions of linear and non-linear theory for all these problems, validating our code. All properties of this hybrid code make it ideal to study multi-scale phenomena between electron and ion scales such as collisionless shocks, magnetic reconnection and kinetic plasma turbulence in the dissipation range above the electron scales.

  1. 29 CFR 1607.14 - Technical standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ..., if the behavior results in work product(s), an analysis of the work product(s). Any job analysis.... This job analysis should show the work behavior(s) required for successful performance of the job, or... 29 Labor 4 2010-07-01 2010-07-01 false Technical standards for validity studies. 1607.14 Section...

  2. Turkish Metalinguistic Awareness Scale: A Validity and Reliability Study

    Science.gov (United States)

    Varisoglu, Behice

    2018-01-01

    The aim of this study is to develop a useful, valid and reliable measurement tool that will help teacher candidates determine their Turkish metalinguistic awareness. During the development of the scale, a pool of items was created by scanning the relevant literature and examining other awareness scales. The materials prepared were re-examined…

  3. Development of a Digital Citizenship Scale for Youth: A Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Zafer KUŞ

    2017-12-01

    Full Text Available The main objective of this study is to develop a valid and reliable scale for identifying digital citizenship perceptions of young people in the most common age groups. The study was conducted as a survey study. The study group of this study is composed of 438 people in Turkey who are among 16-24 age group with the highest rate of internet use in Turkey. An exploratory factor analysis was performed to determine the validity of the scale and the item discrimination powers were calculated. The total variance of the scale was determined that the scale had 8-factor structure and was found to be 49,70%. The internal consistency level was also calculated to determine the reliability of the scale. As a result, it can be said that this scale is a valid and reliable scale that can be used to determine the digital citizenship perceptions of young people.

  4. Improving the Assessment of Pediatric Chronic Pain: Harnessing the Potential of Electronic Diaries

    Directory of Open Access Journals (Sweden)

    Jennifer N Stinson

    2009-01-01

    Full Text Available Current methods for evaluating chronic pain in children suffer from methodological problems. Real-time data capture approaches using electronic diaries have been proposed as a new standard for pain measurement. However, there is limited information available regarding the development, feasibility and validity of these approaches in children. The present paper reviews problems with current measures; rationale for developing real-time data capture approaches using electronic diaries; mechanics of developing electronic pain diaries; current evidence regarding their usability, feasibility and validity; and discusses future directions for research in this area.

  5. Study of the electromagnetic form factors of Helium-3 and Tritium nuclei by electron scattering

    International Nuclear Information System (INIS)

    Amroun, A.

    1989-01-01

    Accurate measurements of the tritium electromagnetic form factor demonstrated that, when the exchange currents are included, the theoretical and the experimental data are in agreement. Similar calculations carried out on helium-3 were not satisfactory. In this investigation, a new electromagnetic form factor of helium-3 is measured. The transfer zone of the diffraction spectra concerning the first minimum and the second maximum is considered. The aim of the study is to test on both nuclei the validity and the uncertainties of the models. The scattering of electrons on helium-3 is analyzed. The experiment was performed in the Saclay linear accelerator. The isoscalar and isovector form factors could be differentiated. By comparing the theoretical and the experimental data, it is demonstrated that the use of three body forces in the calculations has no effect on the form factor results [fr

  6. Electron gun design study for the IUCF beam cooling system

    International Nuclear Information System (INIS)

    Friesel, D.L.; Ellison, T.; Jones, W.P.

    1985-01-01

    The design of a low temperature electron beam cooling system for the Indiana University electron-cooled storage ring is in progress. The storage ring, which will accept the light ion beams from the existing k=200, multi-stage cyclotron facility, requires an electron beam variable in energy from about 7 to 275 keV. The electron beam system consists of a high perveance electron gun with Pierce geometry and a flat cathode. The gun and a 28 element accelerating column are immersed in a uniform longitudinal magnetic guide field. A computer modeling study of the system was conducted to determine electron beam density and transverse temperature variations as a function of anode region and accelerator column design parameters. Transverse electron beam temperatures (E /SUB t/ = mc 2 β 2 γ(/theta/ /SUB H/ +/theta/ /SUB v/ )) of less than a few tenths of an electron volt at a maximum current density of 0.4 A/cm 2 are desired over the full energy range. This was achieved in the calculations without the use of resonant focusing for a 2 Amp, 275 keV electron beam. Some systematics of the electron beam temperature variations with system design parameters are presented. A short discussion of the mechanical design of the proposed electron beam system is also given

  7. Adhesion-governed buckling of thin-film electronics on soft tissues

    Directory of Open Access Journals (Sweden)

    Bo Wang

    2016-01-01

    Full Text Available Stretchable/flexible electronics has attracted great interest and attention due to its potentially broad applications in bio-compatible systems. One class of these ultra-thin electronic systems has found promising and important utilities in bio-integrated monitoring and therapeutic devices. These devices can conform to the surfaces of soft bio-tissues such as the epidermis, the epicardium, and the brain to provide portable healthcare functionalities. Upon contractions of the soft tissues, the electronics undergoes compression and buckles into various modes, depending on the stiffness of the tissue and the strength of the interfacial adhesion. These buckling modes result in different kinds of interfacial delamination and shapes of the deformed electronics, which are very important to the proper functioning of the bio-electronic devices. In this paper, detailed buckling mechanics of these thin-film electronics on elastomeric substrates is studied. The analytical results, validated by experiments, provide a very convenient tool for predicting peak strain in the electronics and the intactness of the interface under various conditions.

  8. Perceptions of Organizational Politics Scale (POPS Questionnaire into Turkish: A Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Evrim EROL

    2016-07-01

    Full Text Available In this study it was aimed to make the studies of the translation of Perception of Organizational Politics Scale into Turkish and the validity and reliability of the scale. Perceptions of Organizational Politics Scale’s (POPS validities has been tested in terms of view, content and structure. The application is designed as a two-stage process. In the first stage, face and content validity was tested. In the second stage, it was sought evidences for the construct validity of the scale by making exploratory factor analysis (EFA and then the confirmatory factor analysis (CFA to the data obtained. In determining the reliability of the scale item-total score correlations and Cronbach alpha coefficient was used. The application made for the validity and reliability of the scale was conducted on the data collected from 277 faculty members working in universities’ education faculties. As a method of achieving those faculty members "Simple randomized (random sampling" is used. The psychometric properties of the Turkish version of Perception of Organizational Politics Scale showed that the scale has a satisfactory level of reliability and validity for the Turkish employee sample.

  9. NMR studies of transmembrane electron transport in human erythrocytes

    International Nuclear Information System (INIS)

    Kennett, E.C.; Bubb, W.A.; Kuchel, P.W.

    2002-01-01

    Full text: Electron transport systems exist in the plasma membranes of all cells. These systems appear to play a role in cell growth and proliferation, intracellular signalling, hormone responses, apoptotic events, cell defence and perhaps most importantly they enable the cell to respond to changes in the redox state of both the intra- and extracellular environments. Previously, 13 C NMR has been used to study transmembrane electron transport in human erythrocytes, specifically the reduction of extracellular 13 C-ferricyanide. NMR is a particularly useful tool for studying such systems as changes in the metabolic state of the cell can be observed concomitantly with extracellular reductase activity. We investigated the oxidation of extracellular NADH by human erythrocytes using 1 H and 31 P NMR spectroscopy. Recent results for glucose-starved human erythrocytes indicate that, under these conditions, extracellular NADH can be oxidised at the plasma membrane with the electron transfer across the membrane resulting in reduction of intracellular NAD + . The activity is inhibited by known trans-plasma membrane electron transport inhibitors (capsaicin and atebrin) and is unaffected by inhibition of the erythrocyte Band 3 anion transporter. These results suggest that electron import from extracellular NADH allows the cell to re-establish a reducing environment after the normal redox balance is disturbed

  10. Stress Reactivity to an Electronic Version of the Trier Social Stress Test: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Sage E Hawn

    2015-05-01

    Full Text Available Social stressors that rely on the inclusion of confederates (i.e., Trier Social Stress Test; TSST are often used in clinical laboratory research paradigms to elicit a measurable stress response in participants. Although effective, the TSST is labor intensive and may introduce error variance as a function of confederate race, gender, and/or response characteristics. The present study aimed to develop and validate an electronic version of the TSST (e-TSST. The primary aim was to compare the e-TSST to an e-neutral control condition; the exploratory aim was to compare the magnitude of stress response elicited by the e-TSST to that elicited by the traditional TSST. Forty-three healthy adults were randomized to the e-TSST or e-neutral condition. Subjective (participant-rated distress and objective (cortisol, heart rate and blood pressure indices of stress were collected prior to, and multiple times following, the stressor. Using archival data collected from 19 healthy participants exposed to the traditional TSST in a prior study, stress reactivity was compared between the electronic and traditional versions of the TSST. The e-TSST elicited significant increases in all measures of stress reactivity compared to the e-neutral condition, with the exception of heart rate (HR. Results showed that the magnitude of subjective distress, BP, and HR responses elicited by the e-TSST did not differ significantly from that elicited by the traditional TSST. The traditional TSST elicited significantly higher cortisol than the e-TSST. Although these findings provide initial support for the development of electronic versions of the TSST, further refinement of the e-TSST is warranted prior to broad adoption of this technology. A refined, reliable e-TSST could allow for increased utilization of the TSST by enhancing convenience, reducing labor costs, and limiting potential error variance introduced by human confederates.

  11. Optimization of power output and study of electron beam energy spread in a Free Electron Laser oscillator

    CERN Document Server

    Abramovich, A; Efimov, S; Gover, A; Pinhasi, Y; Yahalom, A

    2001-01-01

    Design of a multi-stage depressed collector for efficient operation of a Free Electron Laser (FEL) oscillator requires knowledge of the electron beam energy distribution. This knowledge is necessary to determine the voltages of the depressed collector electrodes that optimize the collection efficiency and overall energy conversion efficiency of the FEL. The energy spread in the electron beam is due to interaction in the wiggler region, as electrons enter the interaction region at different phases relative to the EM wave. This interaction can be simulated well by a three-dimensional simulation code such as FEL3D. The main adjustable parameters that determine the electron beam energy spread after interaction are the e-beam current, the initial beam energy, and the quality factor of the resonator out-coupling coefficient. Using FEL3D, we study the influence of these parameters on the available radiation power and on the electron beam energy distribution at the undulator exit. Simulations performed for I=1.5 A, E...

  12. Auroral electron acceleration

    International Nuclear Information System (INIS)

    Bryant, D.A.

    1989-10-01

    Two theories of auroral electron acceleration are discussed. Part 1 examines the currently widely held view that the acceleration is an ordered process in a quasi-static electric field. It is suggested that, although there are many factors seeming to support this theory, the major qualifications and uncertainties that have been identified combine to cast serious doubt over its validity. Part 2 is devoted to a relatively new interpretation in terms of stochastic acceleration in turbulent electric fields. This second theory, which appears to account readily for most known features of the electron distribution function, is considered to provide a more promising approach to this central question in magnetospheric plasma physics. (author)

  13. Design and Implementation Content Validity Study: Development of an instrument for measuring Patient-Centered Communication

    Directory of Open Access Journals (Sweden)

    Vahid Zamanzadeh

    2015-06-01

    Full Text Available ABSTRACT Introduction: The importance of content validity in the instrument psychometric and its relevance with reliability, have made it an essential step in the instrument development. This article attempts to give an overview of the content validity process and to explain the complexity of this process by introducing an example. Methods: We carried out a methodological study conducted to examine the content validity of the patient-centered communication instrument through a two-step process (development and judgment. At the first step, domain determination, sampling (item generation and instrument formation and at the second step, content validity ratio, content validity index and modified kappa statistic was performed. Suggestions of expert panel and item impact scores are used to examine the instrument face validity. Results: From a set of 188 items, content validity process identified seven dimensions includes trust building (eight items, informational support (seven items, emotional support (five items, problem solving (seven items, patient activation (10 items, intimacy/friendship (six items and spirituality strengthening (14 items. Content validity study revealed that this instrument enjoys an appropriate level of content validity. The overall content validity index of the instrument using universal agreement approach was low; however, it can be advocated with respect to the high number of content experts that makes consensus difficult and high value of the S-CVI with the average approach, which was equal to 0.93. Conclusion: This article illustrates acceptable quantities indices for content validity a new instrument and outlines them during design and psychometrics of patient-centered communication measuring instrument.

  14. Introduction of a new instrument to measure motivation for gaming: the electronic gaming motives questionnaire.

    Science.gov (United States)

    Myrseth, Helga; Notelaers, Guy; Strand, Leif Åge; Borud, Einar Kristian; Olsen, Olav Kjellevold

    2017-09-01

    To adapt the four-dimensional Gambling Motives Questionnaire-Revised (GMQ-R) to measure the motivation for engaging in electronic gaming, and to validate the internal structure and investigate the criterion validity of the new Electronic Gaming Motives Questionnaire (EGMQ). The GMQ-R was adapted to measure motivation for playing video games and the new instrument was tested on a sample of Norwegian conscripts selected randomly from the pool of conscripts who started their military service between 2013 and 2015. The questionnaire was administered to all those who had played video games during the last 6 months and consisted of 853 gamers (86.8% men, mean age = 19.4 years). All participants completed the EGMQ, as well as other measures of gaming behaviour, gaming problems, boredom, loneliness and depression. The confirmatory factor analyses showed that the proposed EGMQ (measuring enhancement, coping, social and self-gratification motives) displayed satisfactory fit and internal consistency. Hierarchical regression analyses showed that gender emerged as a significant predictor (P motivational dimensions explained an additional 5.8-38.8% of the variance. Coping and self-gratification predicted gaming problems (P motivational dimensions were also predicted differentially by indicators of psychosocial wellbeing, indicating divergent validity of the four motives. The four-dimensional Electronic Gaming Motives Questionnaire is a valid instrument for measuring motives for gaming. © 2017 Society for the Study of Addiction.

  15. Electron collision cross section sets of TMS and TEOS vapours

    Science.gov (United States)

    Kawaguchi, S.; Takahashi, K.; Satoh, K.; Itoh, H.

    2017-05-01

    Reliable and detailed sets of electron collision cross sections for tetramethylsilane [TMS, Si(CH3)4] and tetraethoxysilane [TEOS, Si(OC2H5)4] vapours are proposed. The cross section sets of TMS and TEOS vapours include 16 and 20 kinds of partial ionization cross sections, respectively. Electron transport coefficients, such as electron drift velocity, ionization coefficient, and longitudinal diffusion coefficient, in those vapours are calculated by Monte Carlo simulations using the proposed cross section sets, and the validity of the sets is confirmed by comparing the calculated values of those transport coefficients with measured data. Furthermore, the calculated values of the ionization coefficient in TEOS/O2 mixtures are compared with measured data to confirm the validity of the proposed cross section set.

  16. Validation of self-reported cannabis dose and potency: an ecological study

    NARCIS (Netherlands)

    van der Pol, P.; Liebregts, N.; de Graaf, R.; Korf, D.J.; van den Brink, W.; van Laar, M.

    2013-01-01

    Aims To assess the reliability and validity of self-reported cannabis dose and potency measures. Design Cross-sectional study comparing self-reports with objective measures of amount of cannabis and delta-9-tetrahydrocannabinol (THC) concentration. Setting Ecological study with assessments at

  17. Density-dependent electron transport and precise modeling of GaN high electron mobility transistors

    Energy Technology Data Exchange (ETDEWEB)

    Bajaj, Sanyam, E-mail: bajaj.10@osu.edu; Shoron, Omor F.; Park, Pil Sung; Krishnamoorthy, Sriram; Akyol, Fatih; Hung, Ting-Hsiang [Department of Electrical and Computer Engineering, The Ohio State University, Columbus, Ohio 43210 (United States); Reza, Shahed; Chumbes, Eduardo M. [Raytheon Integrated Defense Systems, Andover, Massachusetts 01810 (United States); Khurgin, Jacob [Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Rajan, Siddharth [Department of Electrical and Computer Engineering, The Ohio State University, Columbus, Ohio 43210 (United States); Department of Material Science and Engineering, The Ohio State University, Columbus, Ohio 43210 (United States)

    2015-10-12

    We report on the direct measurement of two-dimensional sheet charge density dependence of electron transport in AlGaN/GaN high electron mobility transistors (HEMTs). Pulsed IV measurements established increasing electron velocities with decreasing sheet charge densities, resulting in saturation velocity of 1.9 × 10{sup 7 }cm/s at a low sheet charge density of 7.8 × 10{sup 11 }cm{sup −2}. An optical phonon emission-based electron velocity model for GaN is also presented. It accommodates stimulated longitudinal optical (LO) phonon emission which clamps the electron velocity with strong electron-phonon interaction and long LO phonon lifetime in GaN. A comparison with the measured density-dependent saturation velocity shows that it captures the dependence rather well. Finally, the experimental result is applied in TCAD-based device simulator to predict DC and small signal characteristics of a reported GaN HEMT. Good agreement between the simulated and reported experimental results validated the measurement presented in this report and established accurate modeling of GaN HEMTs.

  18. Density-dependent electron transport and precise modeling of GaN high electron mobility transistors

    International Nuclear Information System (INIS)

    Bajaj, Sanyam; Shoron, Omor F.; Park, Pil Sung; Krishnamoorthy, Sriram; Akyol, Fatih; Hung, Ting-Hsiang; Reza, Shahed; Chumbes, Eduardo M.; Khurgin, Jacob; Rajan, Siddharth

    2015-01-01

    We report on the direct measurement of two-dimensional sheet charge density dependence of electron transport in AlGaN/GaN high electron mobility transistors (HEMTs). Pulsed IV measurements established increasing electron velocities with decreasing sheet charge densities, resulting in saturation velocity of 1.9 × 10 7  cm/s at a low sheet charge density of 7.8 × 10 11  cm −2 . An optical phonon emission-based electron velocity model for GaN is also presented. It accommodates stimulated longitudinal optical (LO) phonon emission which clamps the electron velocity with strong electron-phonon interaction and long LO phonon lifetime in GaN. A comparison with the measured density-dependent saturation velocity shows that it captures the dependence rather well. Finally, the experimental result is applied in TCAD-based device simulator to predict DC and small signal characteristics of a reported GaN HEMT. Good agreement between the simulated and reported experimental results validated the measurement presented in this report and established accurate modeling of GaN HEMTs

  19. A design study of non-adiabatic electron guns

    International Nuclear Information System (INIS)

    Barroso, J.J.; Stellati, C.

    1994-01-01

    The design of a non-adiabatic gun capable of producing a 10 A, 50 KeV high-quality laminar electron beam is reported. In contrast to the magnetron injection gun with a conical cathode, where the beam is generated initially with a transverse velocity component, in the non-adiabatic gun electrons are extracted in a direction parallel to the axial guide magnetic field. The beam electrons acquire cyclotron motion as result of non-adiabatic processes in a strong non uniform electric field across the modulation anode. Such an extraction method gives rise to favourable features that are explored throughout the work. An extensive numerical simulation study has also been done to minimize velocity and energy spreads. (author). 3 refs, 5 figs, 1 tab

  20. Screening for cognitive impairment in older individuals. Validation study of a computer-based test.

    Science.gov (United States)

    Green, R C; Green, J; Harrison, J M; Kutner, M H

    1994-08-01

    This study examined the validity of a computer-based cognitive test that was recently designed to screen the elderly for cognitive impairment. Criterion-related validity was examined by comparing test scores of impaired patients and normal control subjects. Construct-related validity was computed through correlations between computer-based subtests and related conventional neuropsychological subtests. University center for memory disorders. Fifty-two patients with mild cognitive impairment by strict clinical criteria and 50 unimpaired, age- and education-matched control subjects. Control subjects were rigorously screened by neurological, neuropsychological, imaging, and electrophysiological criteria to identify and exclude individuals with occult abnormalities. Using a cut-off total score of 126, this computer-based instrument had a sensitivity of 0.83 and a specificity of 0.96. Using a prevalence estimate of 10%, predictive values, positive and negative, were 0.70 and 0.96, respectively. Computer-based subtests correlated significantly with conventional neuropsychological tests measuring similar cognitive domains. Thirteen (17.8%) of 73 volunteers with normal medical histories were excluded from the control group, with unsuspected abnormalities on standard neuropsychological tests, electroencephalograms, or magnetic resonance imaging scans. Computer-based testing is a valid screening methodology for the detection of mild cognitive impairment in the elderly, although this particular test has important limitations. Broader applications of computer-based testing will require extensive population-based validation. Future studies should recognize that normal control subjects without a history of disease who are typically used in validation studies may have a high incidence of unsuspected abnormalities on neurodiagnostic studies.

  1. Study of the electronic structure of pure aluminium, aluminium oxide and nitride by spectroscopy of electrons excited under electronic and photonic bombardment (X and UV)

    International Nuclear Information System (INIS)

    Gautier-Soyer, Martine

    1985-01-01

    This research thesis reports the use of electron spectroscopy with electrons excited under electronic or photonic (X or UV) bombardment for the study of electronic state density of aluminium, aluminium oxide (Al 2 O 3 ) and aluminium nitride (AlN). The objective is to get an insight into phenomena related to technological problems of adherence, wear, lubrication, corrosion or breakdown met in metals, insulators and semiconductors. The author highlighted the presence of occupied surface states on Al(111) and Al(100), and electronic levels localised in the forbidden band of Al 2 O 3 and AlN, induced by structural defects which promote surface reactivity [fr

  2. Study of the electrons elastic scattering by atoms through pseudopotentials

    International Nuclear Information System (INIS)

    Bettega, M.H.F.

    1990-01-01

    Pseudopotentials allow an extraordinary simplification in the calculation of the electronic structure of atoms, molecules and crystals. Though they have been used extensively for electronic structure calculations, little is known of their applicability to scattering. A study of the pseudopotentials of Bachelet, Hamann and Schuter in the electron scattering by atoms was made, calculating phase-shifts and cross sections for angular momenta 1=0,1 and 2 and energy up to 5 R y. The results for the pseudopotential were compared all-electron calculations. The agreement is very good in a broad energy band. A simplification of the calculation of scattering by complex molecules where an all-electron calculation is impossible is aimed. (author)

  3. Nonquasineutral electron vortices in nonuniform plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Angus, J. R.; Richardson, A. S.; Swanekamp, S. B.; Schumer, J. W. [Plasma Physics Division, Naval Research Laboratory, Washington, District of Columbia 20375 (United States); Ottinger, P. F. [Engility Corporation, Chantilly, Virginia 20151 (United States)

    2014-11-15

    Electron vortices are observed in the numerical simulation of current carrying plasmas on fast time scales where the ion motion can be ignored. In plasmas with nonuniform density n, vortices drift in the B × ∇n direction with a speed that is on the order of the Hall speed. This provides a mechanism for magnetic field penetration into a plasma. Here, we consider strong vortices with rotation speeds V{sub ϕ} close to the speed of light c where the vortex size δ is on the order of the magnetic Debye length λ{sub B}=|B|/4πen and the vortex is thus nonquasineutral. Drifting vortices are typically studied using the electron magnetohydrodynamic model (EMHD), which ignores the displacement current and assumes quasineutrality. However, these assumptions are not strictly valid for drifting vortices when δ ≈ λ{sub B}. In this paper, 2D electron vortices in nonuniform plasmas are studied for the first time using a fully electromagnetic, collisionless fluid code. Relatively large amplitude oscillations with periods that correspond to high frequency extraordinary modes are observed in the average drift speed. The drift speed W is calculated by averaging the electron velocity field over the vorticity. Interestingly, the time-averaged W from these simulations matches very well with W from the much simpler EMHD simulations even for strong vortices with order unity charge density separation.

  4. Defining asthma and assessing asthma outcomes using electronic health record data: a systematic scoping review.

    Science.gov (United States)

    Al Sallakh, Mohammad A; Vasileiou, Eleftheria; Rodgers, Sarah E; Lyons, Ronan A; Sheikh, Aziz; Davies, Gwyneth A

    2017-06-01

    There is currently no consensus on approaches to defining asthma or assessing asthma outcomes using electronic health record-derived data. We explored these approaches in the recent literature and examined the clarity of reporting.We systematically searched for asthma-related articles published between January 1, 2014 and December 31, 2015, extracted the algorithms used to identify asthma patients and assess severity, control and exacerbations, and examined how the validity of these outcomes was justified.From 113 eligible articles, we found significant heterogeneity in the algorithms used to define asthma (n=66 different algorithms), severity (n=18), control (n=9) and exacerbations (n=24). For the majority of algorithms (n=106), validity was not justified. In the remaining cases, approaches ranged from using algorithms validated in the same databases to using nonvalidated algorithms that were based on clinical judgement or clinical guidelines. The implementation of these algorithms was suboptimally described overall.Although electronic health record-derived data are now widely used to study asthma, the approaches being used are significantly varied and are often underdescribed, rendering it difficult to assess the validity of studies and compare their findings. Given the substantial growth in this body of literature, it is crucial that scientific consensus is reached on the underlying definitions and algorithms. Copyright ©ERS 2017.

  5. A Validation Study of Maslow's Hierarchy of Needs Theory.

    Science.gov (United States)

    Clay, Rex J.

    A study was conducted to expand the body of research that tests the validity of Abraham Maslow's hierarchy of needs theory in a work context where it often serves as a guide for the supervisor's relationships with his subordinates. Data was gathered by questionnaire which tested for a hierarchy of needs among instructors at four community colleges…

  6. Simulation study of secondary electron images in scanning ion microscopy

    CERN Document Server

    Ohya, K

    2003-01-01

    The target atomic number, Z sub 2 , dependence of secondary electron yield is simulated by applying a Monte Carlo code for 17 species of metals bombarded by Ga ions and electrons in order to study the contrast difference between scanning ion microscopes (SIM) and scanning electron microscopes (SEM). In addition to the remarkable reversal of the Z sub 2 dependence between the Ga ion and electron bombardment, a fine structure, which is correlated to the density of the conduction band electrons in the metal, is calculated for both. The brightness changes of the secondary electron images in SIM and SEM are simulated using Au and Al surfaces adjacent to each other. The results indicate that the image contrast in SIM is much more sensitive to the material species and is clearer than that for SEM. The origin of the difference between SIM and SEM comes from the difference in the lateral distribution of secondary electrons excited within the escape depth.

  7. Contribution of scanning Auger microscopy to electron beam damage study

    International Nuclear Information System (INIS)

    Fontaine, J.M.

    1983-04-01

    Electron bombardment can produce surface modifications of the analysed sample. The electron beam effects on solid surfaces which have been discussed in the published literature can be classified into the following four categories: (1) heating and its consequent effects, (2) charge accumulation in insulators and its consequent effects, (3) electron stimulated adsorption (ESA), and (4) electron stimulated desorption and/or decomposition (ESD). In order to understand the physico-chemical processes which take place under electron irradiation in an Al-O system, we have carried out experiments in which, effects, such as heating, charging and gas contamination, were absent. Our results point out the role of an enhanced surface diffusion of oxygen during electron bombardment of an Al (111) sample. The importance of this phenomenon and the contribution of near-elastic scattering of the primary electrons (5 keV) to the increase of the oxidation degree observed on Al (111) are discussed, compared to the generally studied effects

  8. Validation of the openEHR archetype library by using OWL reasoning.

    Science.gov (United States)

    Menárguez-Tortosa, Marcos; Fernández-Breis, Jesualdo Tomás

    2011-01-01

    Electronic Health Record architectures based on the dual model architecture use archetypes for representing clinical knowledge. Therefore, ensuring their correctness and consistency is a fundamental research goal. In this work, we explore how an approach based on OWL technologies can be used for such purpose. This method has been applied to the openEHR archetype repository, which is the largest available one nowadays. The results of this validation are also reported in this study.

  9. Validity of Saha's equation of thermal ionization for negatively charged spherical particles in complex plasmas in thermal equilibrium

    International Nuclear Information System (INIS)

    Sodha, M. S.; Mishra, S. K.

    2011-01-01

    The authors have discussed the validity of Saha's equation for the charging of negatively charged spherical particles in a complex plasma in thermal equilibrium, even when the tunneling of the electrons, through the potential energy barrier surrounding the particle is considered. It is seen that the validity requires the probability of tunneling of an electron through the potential energy barrier surrounding the particle to be independent of the direction (inside to outside and vice versa) or in other words the Born's approximation should be valid.

  10. Implementation and validation of the condensation model for containment hydrogen distribution studies

    International Nuclear Information System (INIS)

    Ravva, Srinivasa Rao; Iyer, Kannan N.; Gupta, S.K.; Gaikwad, Avinash J.

    2014-01-01

    Highlights: • A condensation model based on diffusion was implemented in FLUENT. • Validation of a condensation model for the H 2 distribution studies was performed. • Multi-component diffusion is used in the present work. • Appropriate grid and turbulence model were identified. - Abstract: This paper aims at the implementation details of a condensation model in the CFD code FLUENT and its validation so that it can be used in performing the containment hydrogen distribution studies. In such studies, computational fluid dynamics simulations are necessary for obtaining accurate predictions. While steam condensation plays an important role, commercial CFD codes such as FLUENT do not have an in-built condensation model. Therefore, a condensation model was developed and implemented in the FLUENT code through user defined functions (UDFs) for the sink terms in the mass, momentum, energy and species balance equations together with associated turbulence quantities viz., kinetic energy and dissipation rate. The implemented model was validated against the ISP-47 test of TOSQAN facility using the standard wall functions and enhanced wall treatment approaches. The best suitable grid size and the turbulence model for the low density gas (He) distribution studies are brought out in this paper

  11. Study of electron temperature evolution during sawtoothing and pellet injection using thermal electron cyclotron emission in the Alcator C tokamak

    International Nuclear Information System (INIS)

    Gomez, C.C.

    1986-05-01

    A study of the electron temperature evolution has been performed using thermal electron cyclotron emission. A six channel far infrared polychromator was used to monitor the radiation eminating from six radial locations. The time resolution was <3 μs. Three events were studied, the sawtooth disruption, propagation of the sawtooth generated heatpulse and the electron temperature response to pellet injection. The sawtooth disruption in Alcator takes place in 20 to 50 μs, the energy mixing radius is approx. 8 cm or a/2. It is shown that this is inconsistent with single resonant surface Kadomtsev reconnection. Various forms of scalings for the sawtooth period and amplitude were compared. The electron heatpulse propagation has been used to estimate chi e(the electron thermal diffusivity). The fast temperature relaxation observed during pellet injection has also been studied. Electron temperature profile reconstructions have shown that the profile shape can recover to its pre-injection form in a time scale of 200 μs to 3 ms depending on pellet size

  12. Validation of self-reported cannabis dose and potency: an ecological study

    NARCIS (Netherlands)

    van der Pol, Peggy; Liebregts, Nienke; de Graaf, Ron; Korf, Dirk J.; van den Brink, Wim; van Laar, Margriet

    2013-01-01

    To assess the reliability and validity of self-reported cannabis dose and potency measures. Cross-sectional study comparing self-reports with objective measures of amount of cannabis and delta-9-tetrahydrocannabinol (THC) concentration. Ecological study with assessments at participants' homes or in

  13. International validation study for interim PET in ABVD-treated, advanced-stage hodgkin lymphoma

    DEFF Research Database (Denmark)

    Biggi, Alberto; Gallamini, Andrea; Chauvie, Stephane

    2013-01-01

    At present, there are no standard criteria that have been validated for interim PET reporting in lymphoma. In 2009, an international workshop attended by hematologists and nuclear medicine experts in Deauville, France, proposed to develop simple and reproducible rules for interim PET reporting...... in lymphoma. Accordingly, an international validation study was undertaken with the primary aim of validating the prognostic role of interim PET using the Deauville 5-point score to evaluate images and with the secondary aim of measuring concordance rates among reviewers using the same 5-point score...

  14. Silicon passivation study under low energy electron irradiation conditions

    International Nuclear Information System (INIS)

    Cluzel, R.

    2010-01-01

    Backside illuminated thinned CMOS (Complementary Metal Oxide Semiconductor) imaging system is a technology developed to increase the signal to noise ratio and the sensibility of such sensors. This configuration is adapted to the electrons detection from the energy range of [1 - 12 keV]. The impinging electron creates by multiplication several hundreds of secondary electrons close to the surface. A P ++ highly-doped passivation layer of the rear face is required to reduce the secondary electron surface recombination rate. Thanks to the potential barrier induced by the P ++ layer, the passivation layer increases the collected charges number and so the sensor collection gain. The goal of this study is to develop some experimental methods in order to determine the effect of six different passivation processes on the collection gain. Beforehand, the energy profile deposited by an incident electron is studied with the combination of Monte-Carlo simulations and some analytical calculations. The final collection gain model shows that the mirror effect from the passivation layer is a key factor at high energies whereas the passivation layer has to be as thin as possible at low energies. A first experimental setup which consists in irradiating P ++ /N large diodes allows to study the passivation process impacts on the surface recombinations. Thanks to a second setup based on a single event upset directly on thinned CMOS sensor, passivation techniques are discriminated in term of mirror effect and the implied spreading charges. The doping atoms activation laser annealing is turn out to be a multiplication gain inhomogeneity source impacting directly the matrix uniformity. (author)

  15. Harmony in Life Scale - Turkish version: Studies of validity and reliability

    Directory of Open Access Journals (Sweden)

    Seydi Ahmet Satici

    2017-11-01

    Full Text Available Abstract This article presents the adaptation and psychometric evaluation of the Turkish version of Harmony in Life Scale (Turkish-HiL. The present paper investigates (study 1; N 1 = 253 confirmatory factor analysis, measurement invariance; (study 2; N 2 = 231 concurrent validity; (study 3; N 3 = 260 convergent and known-group validities; (study 4; N t − t = 50 test-retest, Cronbach alpha, and composite reliabilities of the Turkish-HiL. In study 1, based on a confirmatory factor analysis, results confirmed that unidimensional-factor structure. The results suggested that the model demonstrated a configural and metric invariance across the gender groups. In study 2, Turkish-HiL significantly correlated with measures of satisfaction with life, subjective happiness, positive affect, and negative affect. In study 3, Turkish-HiL was predicted positively by flourishing, conversely, negatively predicted by depression, anxiety, and stress. Finally, in study 4, alpha, composite and test-retest reliabilities are acceptable. Overall, the scale presented here may prove useful for satisfactorily assessing, in Turkish, the harmony in life of the university students.

  16. Published diagnostic models safely excluded colorectal cancer in an independent primary care validation study

    NARCIS (Netherlands)

    Elias, Sjoerd G; Kok, Liselotte; Witteman, Ben J M; Goedhard, Jelle G; Romberg-Camps, Mariëlle J L; Muris, Jean W M; de Wit, Niek J; Moons, Karel G M

    OBJECTIVE: To validate published diagnostic models for their ability to safely reduce unnecessary endoscopy referrals in primary care patients suspected of significant colorectal disease. STUDY DESIGN AND SETTING: Following a systematic literature search, we independently validated the identified

  17. Design and validation of an accelerator for an ultracold electron source

    Directory of Open Access Journals (Sweden)

    G. Taban

    2008-05-01

    Full Text Available We describe here a specially designed accelerator structure and a pulsed power supply that are essential parts of a high brightness cold atoms-based electron source. The accelerator structure allows a magneto-optical atom trap to be operated inside of it, and also transmits subnanosecond electric field pulses. The power supply produces high voltage pulses up to 30 kV, with a rise time of up to 30 ns. The resulting electric field inside the structure is characterized with an electro-optic measurement and with an ion time-of-flight experiment. Simulations predict that 100 fC electron bunches, generated from trapped atoms inside the structure, reach an emittance of 0.04 mm mrad and a bunch length of 80 ps.

  18. Desorption of hydrogen from magnesium hydride: in-situ electron diffraction study

    International Nuclear Information System (INIS)

    Paik, B.; Jones, I.P.; Walton, A.; Mann, V.; Book, D.; Harris, I.R.

    2009-01-01

    The dynamics of a phase change has been studied where electron beam in Transmission Electron Microscope (TEM) has been used to transform MgH 2 into magnesium. A combination of in-situ Electron Diffraction (ED) and an in-situ Electron Energy Loss Spectroscopy (EELS) study under ED mode describes the phase transformation in terms of, respectively, change in the crystal structure and Plasmon energy shift. The orientation relation [001] MgH2 //[-2110] Mg and (-110) MgH2 //(0001) Mg , obtained from the ED study, has been used to propose a model for the movements of magnesium atoms in the structural change to describe the dynamics of the process. The in-situ EELS study has been compared with the existing H-desorption model. The study aims to describe the sorption dynamics of hydrogen in MgH 2 which is a base material for a number of promising hydrogen storage systems. (author)

  19. Study of optical and electronic properties of nickel from reflection electron energy loss spectra

    Science.gov (United States)

    Xu, H.; Yang, L. H.; Da, B.; Tóth, J.; Tőkési, K.; Ding, Z. J.

    2017-09-01

    We use the classical Monte Carlo transport model of electrons moving near the surface and inside solids to reproduce the measured reflection electron energy-loss spectroscopy (REELS) spectra. With the combination of the classical transport model and the Markov chain Monte Carlo (MCMC) sampling of oscillator parameters the so-called reverse Monte Carlo (RMC) method was developed, and used to obtain optical constants of Ni in this work. A systematic study of the electronic and optical properties of Ni has been performed in an energy loss range of 0-200 eV from the measured REELS spectra at primary energies of 1000 eV, 2000 eV and 3000 eV. The reliability of our method was tested by comparing our results with the previous data. Moreover, the accuracy of our optical data has been confirmed by applying oscillator strength-sum rule and perfect-screening-sum rule.

  20. Intent inferencing by an intelligent operator's associate - A validation study

    Science.gov (United States)

    Jones, Patricia M.

    1988-01-01

    In the supervisory control of a complex, dynamic system, one potential form of aiding for the human operator is a computer-based operator's associate. The design philosophy of the operator's associate is that of 'amplifying' rather than automating human skills. In particular, the associate possesses understanding and control properties. Understanding allows it to infer operator intentions and thus form the basis for context-dependent advice and reminders; control properties allow the human operator to dynamically delegate individual tasks or subfunctions to the associate. This paper focuses on the design, implementation, and validation of the intent inferencing function. Two validation studies are described which empirically demonstrate the viability of the proposed approach to intent inferencing.

  1. Study on tamper-indicating technology in electronic seals system

    International Nuclear Information System (INIS)

    Xu Xiong; Han Feng; Zuo Guangxia; Zhao Xin; Zhang Quanhu; Di Yuming

    2009-01-01

    To strengthen our national arms control verification technical storage and deepen electronic seals' research, this paper mainly introduces seals' characteristics, functions and work principle, studies on tamper-indicating technology which is a key technology in electronic seals, designs some hardware circuit such as optical transceiver, temperature detection circuit, move detection circuit, re-prized circuit and so on, also designs a software program which is used for recording the destroying or tampering events' information. Experimental results show that electronic seals system can record the destroying or tampering events' information accurately and quickly, and give corresponding tamper-indication. (authors)

  2. External Validity of Electronic Sniffers for Automated Recognition of Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    McKown, Andrew C; Brown, Ryan M; Ware, Lorraine B; Wanderer, Jonathan P

    2017-01-01

    Automated electronic sniffers may be useful for early detection of acute respiratory distress syndrome (ARDS) for institution of treatment or clinical trial screening. In a prospective cohort of 2929 critically ill patients, we retrospectively applied published sniffer algorithms for automated detection of acute lung injury to assess their utility in diagnosis of ARDS in the first 4 ICU days. Radiographic full-text reports were searched for "edema" OR ("bilateral" AND "infiltrate") and a more detailed algorithm for descriptions consistent with ARDS. Patients were flagged as possible ARDS if a radiograph met search criteria and had a PaO 2 /FiO 2 or SpO 2 /FiO 2 of 300 or 315, respectively. Test characteristics of the electronic sniffers and clinical suspicion of ARDS were compared to a gold standard of 2-physician adjudicated ARDS. Thirty percent of 2841 patients included in the analysis had gold standard diagnosis of ARDS. The simpler algorithm had sensitivity for ARDS of 78.9%, specificity of 52%, positive predictive value (PPV) of 41%, and negative predictive value (NPV) of 85.3% over the 4-day study period. The more detailed algorithm had sensitivity of 88.2%, specificity of 55.4%, PPV of 45.6%, and NPV of 91.7%. Both algorithms were more sensitive but less specific than clinician suspicion, which had sensitivity of 40.7%, specificity of 94.8%, PPV of 78.2%, and NPV of 77.7%. Published electronic sniffer algorithms for ARDS may be useful automated screening tools for ARDS and improve on clinical recognition, but they are limited to screening rather than diagnosis because their specificity is poor.

  3. Electron spectroscopy studies in heavy fermions

    International Nuclear Information System (INIS)

    Arko, A.J.

    1986-02-01

    Photoemission experiments (whereby an electron absorbs a packet of light energy and is able to escape from the host material due to its increased energy) can measure directly the energy distribution of electrons in various materials. Our measurements on a recently-discovered class of metallic materials called ''heavy fermions'' show that the electrons that actually carry the electric current in these metals exist only within an extremely narrow range of energies. This range, which we will call the bandwidth, is narrower than that found in ordinary metals like copper by at least a factor of 10. Indeed it is surprising that they can carry electric current at all since such narrow energy ranges (or band widths) are characteristic of electrons confined to their host atoms, as in a non-metal, rather than of electrons that are free to wander through a metal. 8 refs

  4. A systematic review of reliability and objective criterion-related validity of physical activity questionnaires

    Directory of Open Access Journals (Sweden)

    Helmerhorst Hendrik JF

    2012-08-01

    Full Text Available Abstract Physical inactivity is one of the four leading risk factors for global mortality. Accurate measurement of physical activity (PA and in particular by physical activity questionnaires (PAQs remains a challenge. The aim of this paper is to provide an updated systematic review of the reliability and validity characteristics of existing and more recently developed PAQs and to quantitatively compare the performance between existing and newly developed PAQs. A literature search of electronic databases was performed for studies assessing reliability and validity data of PAQs using an objective criterion measurement of PA between January 1997 and December 2011. Articles meeting the inclusion criteria were screened and data were extracted to provide a systematic overview of measurement properties. Due to differences in reported outcomes and criterion methods a quantitative meta-analysis was not possible. In total, 31 studies testing 34 newly developed PAQs, and 65 studies examining 96 existing PAQs were included. Very few PAQs showed good results on both reliability and validity. Median reliability correlation coefficients were 0.62–0.71 for existing, and 0.74–0.76 for new PAQs. Median validity coefficients ranged from 0.30–0.39 for existing, and from 0.25–0.41 for new PAQs. Although the majority of PAQs appear to have acceptable reliability, the validity is moderate at best. Newly developed PAQs do not appear to perform substantially better than existing PAQs in terms of reliability and validity. Future PAQ studies should include measures of absolute validity and the error structure of the instrument.

  5. A systematic review of reliability and objective criterion-related validity of physical activity questionnaires

    Science.gov (United States)

    2012-01-01

    Physical inactivity is one of the four leading risk factors for global mortality. Accurate measurement of physical activity (PA) and in particular by physical activity questionnaires (PAQs) remains a challenge. The aim of this paper is to provide an updated systematic review of the reliability and validity characteristics of existing and more recently developed PAQs and to quantitatively compare the performance between existing and newly developed PAQs. A literature search of electronic databases was performed for studies assessing reliability and validity data of PAQs using an objective criterion measurement of PA between January 1997 and December 2011. Articles meeting the inclusion criteria were screened and data were extracted to provide a systematic overview of measurement properties. Due to differences in reported outcomes and criterion methods a quantitative meta-analysis was not possible. In total, 31 studies testing 34 newly developed PAQs, and 65 studies examining 96 existing PAQs were included. Very few PAQs showed good results on both reliability and validity. Median reliability correlation coefficients were 0.62–0.71 for existing, and 0.74–0.76 for new PAQs. Median validity coefficients ranged from 0.30–0.39 for existing, and from 0.25–0.41 for new PAQs. Although the majority of PAQs appear to have acceptable reliability, the validity is moderate at best. Newly developed PAQs do not appear to perform substantially better than existing PAQs in terms of reliability and validity. Future PAQ studies should include measures of absolute validity and the error structure of the instrument. PMID:22938557

  6. Validation of radioisotopic labelling techniques in gastric emptying studies

    International Nuclear Information System (INIS)

    Corinaldesi, R.; Stanghellini, V.; Raiti, C.; Calamelli, R.; Salgemini, R.; Barbara, L.; Zarabini, G.E.

    1987-01-01

    Several techniques are currently employed to label solid and liquid foods with gamma-emitting radioisotopes in order to carry out gamma-camera gastric emptying studies. The present study describes an in vitro technique for evaluating the labelling stability of some of the most commonly employed radiomarkers of both the solid and liquid phases. Technetium-99m-sulphur colloid ( 99m Tc-SC) in vivo and in vitro labelled liver of chickens and other animal species appears to be almost ideal marker of the solid phase (97% of radioactivity still bound to the solid phase after incubation in gastric juice for 90 minutes). On the contrary, 51 CrCl 3 -beef ground meat (81%) and 99m Tc-SC egg white (69%) are unsatisfactory markers of the solid phase. Likewise, 99m Tc-DTPA and 111 In-DTPA cannot be considered satisfactory fluid-phase agents, because of the high proportion of radioactivity that leaves the liquid phase to become bound to the solid phase (respectively 76% and 49% after 90 minutes of incubation). This validation technique appears to be simple, feasible and reprodicible, and can be applied in any Nuclear Medicine Department to evaluate the validity of the labelling procedures, in order to improve the accuracy of the results of radioisotopic gastric emptying studies

  7. Sexual behavioral abstine HIV/AIDS questionnaire: Validation study of an Iranian questionnaire.

    Science.gov (United States)

    Najarkolaei, Fatemeh Rahmati; Niknami, Shamsaddin; Shokravi, Farkhondeh Amin; Tavafian, Sedigheh Sadat; Fesharaki, Mohammad Gholami; Jafari, Mohammad Reza

    2014-01-01

    This study was designed to assess the validity and reliability of the designed sexual, behavioral abstinence, and avoidance of high-risk situation questionnaire (SBAHAQ), with an aim to construct an appropriate development tool in the Iranian population. A descriptive-analytic study was conducted among female undergraduate students of Tehran University, who were selected through cluster random sampling. After reviewing the questionnaires and investigating face and content validity, internal consistency of the questionnaire was assessed by Cronbach's alpha. Explanatory and confirmatory factor analysis was conducted using SPSS and AMOS 16 Software, respectively. The sample consisted of 348 female university students with a mean age of 20.69 ± 1.63 years. The content validity ratio (CVR) coefficient was 0.85 and the reliability of each section of the questionnaire was as follows: Perceived benefit (PB; 0.87), behavioral intention (BI; 0.77), and self-efficacy (SE; 0.85) (Cronbach's alpha totally was 0.83). Explanatory factor analysis showed three factors, including SE, PB, and BI, with the total variance of 61% and Kaiser-Meyer-Olkin (KMO) index of 88%. These factors were also confirmed by confirmatory factor analysis [adjusted goodness of fitness index (AGFI) = 0.939, root mean square error of approximation (RMSEA) = 0.039]. This study showed the designed questionnaire provided adequate construct validity and reliability, and could be adequately used to measure sexual abstinence and avoidance of high-risk situations among female students.

  8. Positron lifetime studies of electron irradiated copper

    International Nuclear Information System (INIS)

    Hadnagy, T.D.

    1976-01-01

    Single-crystal copper was irradiated with 4.5-MeV electrons producing simple Frenkel defects as well as a significant concentration of divacancies. Mean positron lifetime characteristics, which are sensitive to the presence of vacancies and multivacancies in copper, was monitored after isochronal anneals between 80 and 800 0 K to determine the relative change of characteristic mean lifetimes and their associated intensities. Also a study of the dependence of the mean positron lifetime on the total electron fluence was made and compared with existing theories relating these lifetimes to vacancy or multivacancy concentrations. Numerical data from curve fitting procedures using a conventional trapping model for defect-induced changes in positron lifetimes indicate that upon irradiation with 4.5-MeV electrons at 80 0 K, about 8 percent of the defects produced are divacancy units. Divacancy units appear to be several times more effective in trapping positrons than are monovacancies. Further, the experimental data suggest that the stage III annealing processes in electron-irradiated copper most probably involve the motion and removal of both monovacancies and divacancies. A conglomerate (multivacancy) unit appears to exist as a stable entity even after annealing procedures are carried out at temperatures slightly above the stage III region. Such a stable unit could serve as a nucleation center for the appearance of voids

  9. Monte Carlo application based on GEANT4 toolkit to simulate a laser–plasma electron beam line for radiobiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Lamia, D., E-mail: debora.lamia@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology IBFM CNR – LATO, Cefalù (Italy); Russo, G., E-mail: giorgio.russo@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology IBFM CNR – LATO, Cefalù (Italy); Casarino, C.; Gagliano, L.; Candiano, G.C. [Institute of Molecular Bioimaging and Physiology IBFM CNR – LATO, Cefalù (Italy); Labate, L. [Intense Laser Irradiation Laboratory (ILIL) – National Institute of Optics INO CNR, Pisa (Italy); National Institute for Nuclear Physics INFN, Pisa Section and Frascati National Laboratories LNF (Italy); Baffigi, F.; Fulgentini, L.; Giulietti, A.; Koester, P.; Palla, D. [Intense Laser Irradiation Laboratory (ILIL) – National Institute of Optics INO CNR, Pisa (Italy); Gizzi, L.A. [Intense Laser Irradiation Laboratory (ILIL) – National Institute of Optics INO CNR, Pisa (Italy); National Institute for Nuclear Physics INFN, Pisa Section and Frascati National Laboratories LNF (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology IBFM CNR, Segrate (Italy); University of Milano-Bicocca, Milano (Italy)

    2015-06-21

    We report on the development of a Monte Carlo application, based on the GEANT4 toolkit, for the characterization and optimization of electron beams for clinical applications produced by a laser-driven plasma source. The GEANT4 application is conceived so as to represent in the most general way the physical and geometrical features of a typical laser-driven accelerator. It is designed to provide standard dosimetric figures such as percentage dose depth curves, two-dimensional dose distributions and 3D dose profiles at different positions both inside and outside the interaction chamber. The application was validated by comparing its predictions to experimental measurements carried out on a real laser-driven accelerator. The work is aimed at optimizing the source, by using this novel application, for radiobiological studies and, in perspective, for medical applications. - Highlights: • Development of a Monte Carlo application based on GEANT4 toolkit. • Experimental measurements carried out with a laser-driven acceleration system. • Validation of Geant4 application comparing experimental data with the simulated ones. • Dosimetric characterization of the acceleration system.

  10. Translation of the Leisure Satisfaction Scale into French: a validation study.

    Science.gov (United States)

    Lysyk, Mary; Brown, G Ted; Rodrigues, Erika; McNally, Julie; Loo, Kim

    2002-01-01

    Few standardized instruments are available for clients who speak languages other than English. The purpose of the study was to present and describe the process of translating an English standardized assessment into another language. Using the translation/validation methodologies described by Haccoun (1987) and Vallerand (1989), the Leisure Satisfaction Scale (LSS) was translated into French and then statistically validated. All correlations between both language versions of the LSS were found to be significant at the 0.01 level. Confirmatory factor analysis results were positive. Study findings indicate that the Haccoun (1987) and Vallerand (1989) methodologies provide clinicians with another option for ensuring culturally sensitive and relevant evaluations. Further research is needed to globally assess the measurement properties of the French version of this instrument.

  11. Convergent validity test, construct validity test and external validity test of the David Liberman algorithm

    Directory of Open Access Journals (Sweden)

    David Maldavsky

    2013-08-01

    Full Text Available The author first exposes a complement of a previous test about convergent validity, then a construct validity test and finally an external validity test of the David Liberman algorithm.  The first part of the paper focused on a complementary aspect, the differential sensitivity of the DLA 1 in an external comparison (to other methods, and 2 in an internal comparison (between two ways of using the same method, the DLA.  The construct validity test exposes the concepts underlined to DLA, their operationalization and some corrections emerging from several empirical studies we carried out.  The external validity test examines the possibility of using the investigation of a single case and its relation with the investigation of a more extended sample.

  12. Electron microscopy studies of materials used for hydrogen storage

    Energy Technology Data Exchange (ETDEWEB)

    Andrei, Carmen M.

    2004-07-01

    Concerns over global warming and air pollution have stimulated the concept of the ''Hydrogen Economy'' and the potential extensive use of hydrogen as an energy carrier. Hydrogen storage in a solid matrix has become one of the promising solutions for vehicular applications. In this study, several transmission electron microscopy (TEM) techniques such as high resolution (HR), electron diffraction, energy dispersive X-ray spectroscopy (EDS), electron energy loss spectroscopy (EELS) and energy-filtered transmission electron microscopy (EFT EM) as well as scanning electron microscopy (SEM) have been used to study the microstructure of materials related to hydrogen storage applications. Some of the results are compared with powder X-ray diffraction (PXD) data. A TbNiAl compound processed by the hydrogenation-disproportionation-desorption-recombination (HDDR) route has been studied using a combination of SEM, TEM and PXD. Information about the variations in the composition and surface topography in both disproportionation and recombination stages is given by the SEM backscattered electrons and secondary electrons images. The crystallites that have undergone the recombination process were found smaller in size. The sodium alanate, NaAIH4 is one of the most promising candidate materials for hydrogen storage. Ti additives are effective at reducing the reaction temperatures and improving the efficiency of the kinetics. The microstructure of NaAlH4 with TiF3 additive has been examined after the initial ball milling and after 15 cycles, using TEM, SEM and EDS. The effect of the additive on particle morphology, grain size and distribution of the phases has been studied. The additive has uneven distribution in the sample after initial ball milling. After 15 cycles, EDS maps show some combination of Ti with the alanate phase. No significant change in grain size of the Na/Al rich particles between the ball milled and 15 cycled sample was observed. The LiAlD4

  13. Validation of verbal autopsy methods using hospital medical records: a case study in Vietnam.

    Science.gov (United States)

    Tran, Hong Thi; Nguyen, Hoa Phuong; Walker, Sue M; Hill, Peter S; Rao, Chalapati

    2018-05-18

    Information on causes of death (COD) is crucial for measuring the health outcomes of populations and progress towards the Sustainable Development Goals. In many countries such as Vietnam where the civil registration and vital statistics (CRVS) system is dysfunctional, information on vital events will continue to rely on verbal autopsy (VA) methods. This study assesses the validity of VA methods used in Vietnam, and provides recommendations on methods for implementing VA validation studies in Vietnam. This validation study was conducted on a sample of 670 deaths from a recent VA study in Quang Ninh province. The study covered 116 cases from this sample, which met three inclusion criteria: a) the death occurred within 30 days of discharge after last hospitalisation, and b) medical records (MRs) for the deceased were available from respective hospitals, and c) the medical record mentioned that the patient was terminally ill at discharge. For each death, the underlying cause of death (UCOD) identified from MRs was compared to the UCOD from VA. The validity of VA diagnoses for major causes of death was measured using sensitivity, specificity and positive predictive value (PPV). The sensitivity of VA was at least 75% in identifying some leading CODs such as stroke, road traffic accidents and several site-specific cancers. However, sensitivity was less than 50% for other important causes including ischemic heart disease, chronic obstructive pulmonary diseases, and diabetes. Overall, there was 57% agreement between UCOD from VA and MR, which increased to 76% when multiple causes from VA were compared to UCOD from MR. Our findings suggest that VA is a valid method to ascertain UCOD in contexts such as Vietnam. Furthermore, within cultural contexts in which patients prefer to die at home instead of a healthcare facility, using the available MRs as the gold standard may be meaningful to the extent that recall bias from the interval between last hospital discharge and death

  14. The electronic pressure in dense plasmas

    International Nuclear Information System (INIS)

    Pozwolski, A.E.

    1982-01-01

    A thermodynamic calculation of the electronic pressure in a dense plasma is given. Approximations involved by the use of the Debye length are avoided, so the above theory remains valid even if the Debye length is smaller than the interionic distance. (author)

  15. Monte Carlo study of electron irradiation effect on YBCO dpa profiles

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Van Espen, P.

    2011-01-01

    The Monte Carlo assisted Classical Method (MCCM) consists on a calculation procedure for determining the displacements per atom (dpa) distribution in solid materials. This algorithm allows studying the gamma and electron irradiation damage in different materials. It is based on the electrons elastic scattering classic theories and the use of Monte Carlo simulation for the physical processes involved. The present study deals with the Monte Carlo simulation of electron irradiation effects on YBa 2 Cu 3 O 7-x (YBCO) slabs using the MCNPX code system. Displacements per atom distributions are obtained through the MCCM for electron irradiation up to 10 MeV. In-depth dpa profiles for electrons and positrons are obtained and analyzed. Also, for each atomic species in the material, the dpa distributions are calculated. All the results are discussed in the present contribution. (Author)

  16. Secondary electron emission studied by secondary electron energy loss coincidence spectroscopy (SE2ELCS)

    International Nuclear Information System (INIS)

    Khalid, R.

    2013-01-01

    Emission of secondary electrons is of importance in many branches of fundamental and applied science. It is widely applied in the electron microscope for the investigation of the structure and electronic state of solid surfaces and particle detection in electron multiplier devices, and generally it is related to the energy dissipation of energetic particles moving inside a solid. The process of secondary electron emission is a complex physical phenomenon, difficult to measure experimentally and treat theoretically with satisfactory accuracy. The secondary electron spectrum measured with single electron spectroscopy does not provide detailed information of the energy loss processes responsible for the emission of secondary electrons. This information can be accessed when two correlated electron pairs are measured in coincidence and the pair consists of a backscattered electron after a given energy loss and a resulting emitted secondary electron. To investigate the mechanisms responsible for the emission of secondary electrons, a reflection (e,2e) coincidence spectrometer named Secondary Electron Electron Energy Loss Coincidence Spectrometer (SE2ELCS) has been developed in the framework of this thesis which allows one to uncover the relation between the features in the spectra which are due to energy losses and true secondary electron emission structures. The correlated electron pairs are measured with a hemispherical mirror analyzer (HMA) and a time of flight analyzer (TOF) by employing a continuous electron beam. An effort has been made to increase the coincidence count rate by increasing the effective solid angle of the TOF analyzer and optimizing the experimental parameters to get optimum energy resolution. Double differential coincidence spectra for a number of materials namely, nearly free electron metals (Al, Si), noble metals (Ag, Au, Cu, W) and highly oriented pyrolytic graphite (HOPG) have been measured using this coincidence spectrometer. The

  17. Measuring coverage in MNCH: a validation study linking population survey derived coverage to maternal, newborn, and child health care records in rural China.

    Directory of Open Access Journals (Sweden)

    Li Liu

    Full Text Available Accurate data on coverage of key maternal, newborn, and child health (MNCH interventions are crucial for monitoring progress toward the Millennium Development Goals 4 and 5. Coverage estimates are primarily obtained from routine population surveys through self-reporting, the validity of which is not well understood. We aimed to examine the validity of the coverage of selected MNCH interventions in Gongcheng County, China.We conducted a validation study by comparing women's self-reported coverage of MNCH interventions relating to antenatal and postnatal care, mode of delivery, and child vaccinations in a community survey with their paper- and electronic-based health care records, treating the health care records as the reference standard. Of 936 women recruited, 914 (97.6% completed the survey. Results show that self-reported coverage of these interventions had moderate to high sensitivity (0.57 [95% confidence interval (CI: 0.50-0.63] to 0.99 [95% CI: 0.98-1.00] and low to high specificity (0 to 0.83 [95% CI: 0.80-0.86]. Despite varying overall validity, with the area under the receiver operating characteristic curve (AUC ranging between 0.49 [95% CI: 0.39-0.57] and 0.90 [95% CI: 0.88-0.92], bias in the coverage estimates at the population level was small to moderate, with the test to actual positive (TAP ratio ranging between 0.8 and 1.5 for 24 of the 28 indicators examined. Our ability to accurately estimate validity was affected by several caveats associated with the reference standard. Caution should be exercised when generalizing the results to other settings.The overall validity of self-reported coverage was moderate across selected MNCH indicators. However, at the population level, self-reported coverage appears to have small to moderate degree of bias. Accuracy of the coverage was particularly high for indicators with high recorded coverage or low recorded coverage but high specificity. The study provides insights into the accuracy of

  18. Environmental dose rate heterogeneity of beta radiation and its implications for luminescence dating: Monte Carlo modelling and experimental validation

    DEFF Research Database (Denmark)

    Nathan, R.P.; Thomas, P.J.; Jain, M.

    2003-01-01

    and identify the likely size of these effects on D-e distributions. The study employs the MCNP 4C Monte Carlo electron/photon transport model, supported by an experimental validation of the code in several case studies. We find good agreement between the experimental measurements and the Monte Carlo...

  19. Study of relativistic electron beams generated by a foilless diode

    International Nuclear Information System (INIS)

    Jones, M.E.; Thode, L.E.

    1979-01-01

    Preliminary results of a numerical and analytical study of foilless diodes are presented. The work produced an electron emission algorithm for the particle-in-cell simulation code CCUBE. Diode performance was studied as a function of applied magnetic field strength and simple geometry changes. Annular electron beams with an energy of 5 MeV appear obtainable with densities exceeding 10 14 cm -3 . 8 figures

  20. Ultrafast electron diffraction studies of optically excited thin bismuth films

    International Nuclear Information System (INIS)

    Rajkovic, Ivan

    2008-01-01

    This thesis contains work on the design and the realization of an experimental setup capable of providing sub-picosecond electron pulses for ultrafast electron diffraction experiments, and performing the study of ultrafast dynamics in bismuth after optical excitation using this setup. (orig.)

  1. Ultrafast electron diffraction studies of optically excited thin bismuth films

    Energy Technology Data Exchange (ETDEWEB)

    Rajkovic, Ivan

    2008-10-21

    This thesis contains work on the design and the realization of an experimental setup capable of providing sub-picosecond electron pulses for ultrafast electron diffraction experiments, and performing the study of ultrafast dynamics in bismuth after optical excitation using this setup. (orig.)

  2. Monitoring dietary intake and physical activity electronically: feasibility, usability, and ecological validity of a mobile-based Ecological Momentary Assessment tool.

    Science.gov (United States)

    Spook, Jorinde Eline; Paulussen, Theo; Kok, Gerjo; Van Empelen, Pepijn

    2013-09-24

    Despite the growing body of research on complex lifestyle behaviors (eg, Dietary Intake [DI] and Physical Activity [PA]), monitoring of these behaviors has been hampered by a lack of suitable methods. A possible solution to this deficiency is mobile-based Ecological Momentary Assessment (mEMA), which enables researchers to collect data on participants' states in real-time by means of a smartphone application. However, feasibility, usability, and ecological validity need to be anticipated and managed in order to enhance the validity of mEMA. To examine the feasibility, usability, and ecological validity of a mEMA application (app) with regard to DI and PA among Dutch vocational education students. The students (n=30) participated in the mEMA study for seven consecutive days. They downloaded the mEMA app on their smartphone. Feasibility and usability of the mEMA app were evaluated by completing an online evaluation after seven days of participation. Ecological validity was measured by assessing the degree to which the content of the mEMA app approximated the real-world setting that was being examined, through several multiple-choice questions. Compliance rates, as registered by the mEMA app, declined 46% over a seven-day period, while self-reported compliance, as measured with an online evaluation questionnaire afterwards, indicated a smaller decrease in compliance (29%). The students evaluated the mEMA app as feasible and usable. Ecological validity analyses showed that all DI and almost all PA multiple-choice options were covered with the compound response categories. The mEMA app offers the opportunity to assess complex health behaviors (eg, DI and PA) in real-time settings, in which specifically routinized behaviors are involved. However, the mEMA app faced several challenges that needed to be overcome in order to improve its validity. Overall, the present study showed that the mEMA app is a usable and ecologically valid tool to measure DI and PA behaviors among

  3. Novel Automated Morphometric and Kinematic Handwriting Assessment: A Validity Study in Children with ASD and ADHD

    Science.gov (United States)

    Dirlikov, Benjamin; Younes, Laurent; Nebel, Mary Beth; Martinelli, Mary Katherine; Tiedemann, Alyssa Nicole; Koch, Carolyn A.; Fiorilli, Diana; Bastian, Amy J.; Denckla, Martha Bridge; Miller, Michael I.; Mostofsky, Stewart H.

    2017-01-01

    This study presents construct validity for a novel automated morphometric and kinematic handwriting assessment, including (1) convergent validity, establishing reliability of automated measures with traditional manual-derived Minnesota Handwriting Assessment (MHA), and (2) discriminant validity, establishing that the automated methods distinguish…

  4. Chlorine-36 validation Study at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    J. Paces

    2006-01-01

    The amount, spatial distribution, and velocity of water percolating through the unsaturated zone (UZ) at Yucca Mountain, Nevada, are important issues for assessing the performance of the proposed deep geologic repository for spent nuclear fuel and high-level radioactive waste. To help characterize the nature and history of UZ flow, isotopic studies were initiated in 1995, using rock samples collected from the Miocene ash-flow tuffs in the Exploratory Studies Facility (ESF), an 8-km-long tunnel constructed along the north-south extent of the repository block, and the Enhanced Characterization of the Repository Block (ECRB) Cross Drift, a 2.5-km-long tunnel constructed across the repository block (Figure 1-1, Sources: Modified from DOE 2002 [Figure 1-14] and USBR 1996). Scientists from Los Alamos National Laboratory (LANL) analyzed for chlorine-36 ( 36 Cl) in salts leached from whole-rock samples collected from tunnel walls and subsurface boreholes, and scientists from the U.S. Geological Survey (USGS) analyzed for isotopes of oxygen, carbon, uranium, lead, thorium, and strontium in secondary minerals collected from subsurface fractures and lithophysal cavities. Elevated values for ratios of 36 Cl to total chloride ( 36 Cl/CL) at the level of the proposed repository indicated that small amounts of water carrying bomb-pulse 36 Cl (i.e., 36 Cl/Cl ratios greater than 1250 x 10 -15 resulting from 36 Cl produced by atmospheric testing of nuclear devices during the 1950s and early 1960s) had percolated through welded and nonwelded tuffs to depths of 200 to 300 meters (m) beneath the land surface over the past 50 years. Because of the implications of short travel times to the performance of the proposed repository, the U.S. Department of Energy (DOE)/Office of Civilian Radioactive Waste Management (OCRWM), Office of Repository Development (ORD), decided to verify the 36 Cl/Cl data with an independent validation study. DOE asked the USGS to design and implement a validation

  5. Validation of search filters for identifying pediatric studies in PubMed

    NARCIS (Netherlands)

    Leclercq, Edith; Leeflang, Mariska M. G.; van Dalen, Elvira C.; Kremer, Leontien C. M.

    2013-01-01

    To identify and validate PubMed search filters for retrieving studies including children and to develop a new pediatric search filter for PubMed. We developed 2 different datasets of studies to evaluate the performance of the identified pediatric search filters, expressed in terms of sensitivity,

  6. Can Electron-Rich Oxygen (O2-) Withdraw Electrons from Metal Centers? A DFT Study on Oxoanion-Caged Polyoxometalates.

    Science.gov (United States)

    Takazaki, Aki; Eda, Kazuo; Osakai, Toshiyuki; Nakajima, Takahito

    2017-10-12

    The answer to the question "Can electron-rich oxygen (O 2- ) withdraw electrons from metal centers?" is seemingly simple, but how the electron population on the M atom behaves when the O-M distance changes is a matter of controversy. A case study has been conducted for Keggin-type polyoxometalate (POM) complexes, and the first-principles electronic structure calculations were carried out not only for real POM species but also for "hypothetical" ones whose heteroatom was replaced with a point charge. From the results of natural population analysis, it was proven that even an electron-rich O 2- , owing to its larger electronegativity as a neutral atom, withdraws electrons when electron redistribution occurs by the change of the bond length. In the case where O 2- coexists with a cation having a large positive charge (e.g., P 5+ (O 2- ) 4 = [PO 4 ] 3- ), the gross electron population (GEP) on the M atom seemingly increases as the O atom comes closer, but this increment in GEP is not due to the role of the O atom but due to a Coulombic effect of the positive charge located on the cation. Furthermore, it was suggested that not GEP but net electron population (NEP) should be responsible for the redox properties.

  7. Dynamic electron arc radiotherapy (DEAR): a feasibility study

    International Nuclear Information System (INIS)

    Rodrigues, Anna; Yin, Fang-Fang; Wu, Qiuwen

    2014-01-01

    Compared to other radiation therapy modalities, clinical electron beam therapy has remained practically unchanged for the past few decades even though electron beams with multiple energies are widely available on most linacs. In this paper, we present the concept of dynamic electron arc radiotherapy (DEAR), a new conformal electron therapy technique with synchronized couch motion. DEAR utilizes combination of gantry rotation, couch motion, and dose rate modulation to achieve desirable dose distributions in patient. The electron applicator is kept to minimize scatter and maintain narrow penumbra. The couch motion is synchronized with the gantry rotation to avoid collision between patient and the electron cone. In this study, we investigate the feasibility of DEAR delivery and demonstrate the potential of DEAR to improve dose distributions on simple cylindrical phantoms. DEAR was delivered on Varian's TrueBeam linac in Research Mode. In conjunction with the recorded trajectory log files, mechanical motion accuracies and dose rate modulation precision were analyzed. Experimental and calculated dose distributions were investigated for different energies (6 and 9 MeV) and cut-out sizes (1×10 cm 2  and 3×10 cm 2  for a 15×15 cm 2  applicator). Our findings show that DEAR delivery is feasible and has the potential to deliver radiation dose with high accuracy (root mean square error, or RMSE of <0.1 MU, <0.1° gantry, and <0.1 cm couch positions) and good dose rate precision (1.6 MU min −1 ). Dose homogeneity within ±2% in large and curved targets can be achieved while maintaining penumbra comparable to a standard electron beam on a flat surface. Further, DEAR does not require fabrication of patient-specific shields. These benefits make DEAR a promising technique for conformal radiotherapy of superficial tumors. (paper)

  8. Sleep quality, the neglected outcome variable in clinical studies focusing on locomotor system; a construct validation study

    Directory of Open Access Journals (Sweden)

    Röder Christoph

    2010-09-01

    Full Text Available Abstract Background In addition to general health and pain, sleep is highly relevant to judging the well-being of an individual. Of these three important outcome variables, however, sleep is neglected in most outcome studies. Sleep is a very important resource for recovery from daily stresses and strains, and any alteration of sleep will likely affect mental and physical health, especially during disease. Sleep assessment therefore should be standard in all population-based or clinical studies focusing on the locomotor system. Yet current sleep assessment tools are either too long or too specific for general use. Methods Based on a literature review and subsequent patient-based rating of items, an expert panel designed a four-item questionnaire about sleep. Construct validation of the questionnaire in a random sample of the German-speaking Swiss population was performed in 2003. Reliability, correlation, and tests for internal consistency and validity were analyzed. Results Overall, 16,634 (70% out of 23,763 eligible individuals participated in the study. Test-retest reliability coefficients ranged from 0.72 to 0.87, and a Cronbach's alpha of 0.83 indicates good internal consistency. Results show a moderate to good correlation between sleep disturbances and health perception, and between sleep disturbances and overall pain. Conclusions The Sleep Standard Evaluation Questionnaire (SEQ-Sleep is a reliable and short tool with confirmed construct validity for sleep assessment in population-based observational studies. It is easy to administer and therefore suitable for postal surveys of the general population. Criterion validity remains to be determined.

  9. About the close collisions of the fast positrons and electrons with the string atoms

    International Nuclear Information System (INIS)

    Kudrin, V.V.; Vorobiev, S.A.

    1975-01-01

    The penetration behaviour of 20 MeV electron in MgO single crystal was studied. In the calculations the early described version of the binary collision model based on the classical mechanics was used. The classical theory has been shown to be valid for the scattering of the fast electrons in the crystal lattice. For the comparison with the behaviour of the positive particles the scattering of 20MeV positrons under the same conditions was simulated

  10. An empirical study on critical success factors for electronic commerce in the Chinese publishing industry

    Institute of Scientific and Technical Information of China (English)

    HUANG Jinghua; ZHAO Chunjun; LI Jingting

    2007-01-01

    Critical success factors for electronic commerce (e-commerce) have been a hot topic in both the academe and industry. This paper puts forward hypotheses on success factors for e-commerce of traditional companies first. Then, it conducts an empirical study on the Chinese publishing industry in order to verify the hypotheses. After testing the validity and reliability of the data, this paper verifies the hypotheses with regression analyses, and finally identifies factors impacting e-commerce success such as leadership, strategy, organization, management, IT, customers, comprehensive functions of website and customer- oriented functions. In addition, customers, strategy, IT and comprehensive functions of website are identified as the critical factors impacting e-commerce success. This research not only stimulates e-commerce research in China, but also has an instructional effect on the implementation of e-commerce so that Chinese publishing enterprises can increase the success rate of their e-commerce objectives.

  11. Irradiation-related amorphization and crystallization: In situ transmission electron microscope studies

    International Nuclear Information System (INIS)

    Allen, C.W.

    1994-01-01

    Interfacing an ion accelerator to a transmission electron microscope (TEM) allows the analytical functions of TEM imaging and diffraction to be employed during ion-irradiation effects studies. At present there are twelve such installations in Japan, one in France and one in the US. This paper treats several aspects of in situ studies involving electron and ion beam induced and enhanced phase transformations and presents results of several in situ experiments to illustrate the dynamics of this approach in the materials science of irradiation effects. The paper describes the ion- and electron-induced amorphization of CuTi; the ion-irradiation-enhanced transformation of TiCr 2 ; and the ion- and electron-irradiation-enhanced crystallization of CoSi 2

  12. Improving the Weizsäcker-Williams approximation in electron-proton collisions

    CERN Document Server

    Frixione, Stefano; Nason, P; Ridolfi, G

    1993-01-01

    We critically examine the validity of the Weizs\\"acker-Williams approximation in electron-hadron collisions. We show that in its commonly used form it can lead to large errors, and we show how to improve it in order to get accurate results. In particular, we present an improved form that is valid beyond the leading logarithmic approximation in the case when a small-angle cut is applied to the scattered electron. Furthermore we include comparisons of the approximate expressions with the exact electroproduction calculation in the case of heavy-quark production.

  13. A Validation Study of the Student Oral Proficiency Assessment (SOPA).

    Science.gov (United States)

    Thompson, Lynn E.; Kenyon, Dorry M.; Rhodes, Nancy C.

    This study validated the Student Oral Proficiency Assessment (SOPA), an oral proficiency instrument designed for students in elementary foreign language programs. Elementary students who were tested with the SOPA were also administered other instruments designed to measure proficiency. These instruments included the Stanford Foreign Language Oral…

  14. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1991-01-01

    This year our laboratory has continued to make progress in the design of electron-optical systems, in the study of structure-function relationships of large multi-subunit proteins, in the development of new image processing software and in achieving a workable sub-angstrom STEM. We present an algebraic approach to the symmetrical Einzel (unipotential) lens wherein we simplify the analysis by specifying a field shape that meets some preferred set of boundary or other conditions and then calculate the fields. In a second study we generalize this approach to study of three element electrostatic lenses of which the symmetrical Einzel lens is a particular form. The purpose is to develop a method for assisting in the design of a lens for a particular purpose. In our biological work we study a stable and functional dodecameric complex of globin chains from the hemoglobin of Lumbricus terrestris. This is a complex lacking the ''linker'' subunit first imaged in this lab and required for maintenance of the native structure. In addition, we do a complete work-up on the hemoglobin of the marine polychaete Eudistylia vancouverii demonstrating the presence of a hierarchy of globin complexes. We demonstrate stable field-emission in the sub-angstrom STEM and the preliminary alignment of the beam. We continue our exploration of a algorithms for alignment of sequences of protein and DNA. Our computer facilities now include four second generation RISC workstations and we continue to take increasing advantage of the floating-point and graphical performance of these devices

  15. A study of core electron binding energies in technetium-99m complexes by internal conversion electron spectroscopy

    International Nuclear Information System (INIS)

    Burke, J.F.; Archer, C.M.; Wei Chiu, K.; Latham, I.A.; Egdell, R.G.

    1991-01-01

    Core electron binding energies in a series of 99m Tc complexes have been studied by internal conversion electron spectroscopy (ICES) in a conventional x-ray photoelectron spectrometer. In both 3d and 3p regions, a chemical shift of about 1 eV is observed per unit increase in oxidation state. The role of ICES in characterizing radiopharmaceutical agents is illustrated with studies of some novel 99m Tc-phosphine complexes that have been developed for myocardial perfusion imaging. (author)

  16. Study of Compton broadening due to electron-photon scattering

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao M.

    2010-01-01

    Full Text Available We have investigated the effects of Compton broadening due to electron-photon scattering in hot stellar atmospheres. A purely electron-photon scattering media is assumed to have plane parallel geometry with an input radia­tion field localized on one side of the slab. The method is based on the discrete space theory of radiative transfer for the intensity of emitted radiation. The solution is developed to study the importance of scattering of radiation by free electrons in high temperature stellar atmospheres which produces a brodening and shift in spectral lines because of the Compton effect and the Doppler effect arising from mass and thermal motions of scattering electrons. It is noticed that the Comptonized spectrum depends on three parameters: the optical depth of the medium, the temperature of the thermal electrons and the viewing angle. We also showed that the Compton effect produces red shift and asymmetry in the line. These two effects increase as the optical depth increases. It is also noticed that the emergent specific intensities become completely asymmetric for higher optical depths.

  17. Study of Compton Broadening Due to Electron-Photon Scattering

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao, M.

    2010-06-01

    Full Text Available We have investigated the effects of Compton broadening due to electron-photon scattering in hot stellar atmospheres. A purely electron-photon scattering media is assumed to have plane parallel geometry with an input radiation field localized on one side of the slab. The method is based on the discrete space theory of radiative transfer for the intensity of emitted radiation.The solution is developed to study the importance of scattering of radiation by free electrons in high temperature stellar atmospheres which produces a brodening and shift in spectral lines because of the Compton effect and the Doppler effect arising from mass and thermal motions of scattering electrons.It is noticed that the Comptonized spectrum depends on three parameters: the optical depth of the medium, the temperature of the thermal electrons and the viewing angle.We also showed that the Compton effect produces red shift and asymmetry in the line. These two effects increase as the optical depth increases. It is also noticed that the emergent specific intensities become completely asymmetric for higher optical depths.

  18. Dosimetry study for electron beam irradiation in radiation processing

    International Nuclear Information System (INIS)

    Sunaga, Hiromi; Haruyama, Yasuyuki; Takizawa, Haruki; Kojima, Takuji; Yotsumoto, Keiichi

    1995-01-01

    For certain critical applications such as medical device sterilization and food irradiation, accurate calibration of electron energy and absorbed dose is required to assure the quality of irradiated products. To meet this requirement, TRCRE, JAERI has carried out research and development on high dose radiation dosimetry for electron beams in the energy range used in radiation processing (0.15 - 3.0 MeV). JAERI has developed a simultaneous electron beam energy and dosimeter calibration system that consist of a total absorption calorimeter, an electron current density meter, and a stacked thin-film dosimeter set. For low energy electrons, where it is important to measure the depth-dose profile in materials with high depth resolution, we studied the feasibility of a method using Gafchromic film dosimeters. This film, which has an 8-μm thick sensitive layer, is combined with a stepped array of absorber films of the same thickness to produce a high-resolution depth-dose profile on the Gafchromic film. The depth-dose profile obtained in this manner has about five times greater resolution than conventional radiochromic film dosimetry. (author)

  19. Spin dynamics of electron beams in circular accelerators

    International Nuclear Information System (INIS)

    Boldt, Oliver

    2014-04-01

    Experiments using high energy beams of spin polarized, charged particles still prove to be very helpful in disclosing a deeper understanding of the fundamental structure of matter. An important aspect is to control the beam properties, such as brilliance, intensity, energy, and degree of spin polarization. In this context, the present studies show various numerical calculations of the spin dynamics of high energy electron beams in circular accelerators. Special attention has to be paid to the emission of synchrotron radiation, that occurs when deflecting charged particles on circular orbits. In the presence of the fluctuation of the kinetic energy due to the photon emission, each electron spin moves non-deterministically. This stochastic effect commonly slows down the speed of all numeric estimations. However, the shown simulations cover - using appropriate approximations - trackings for the motion of thousands of electron spins for up to thousands of turns. Those calculations are validated and complemented by empirical investigations at the electron stretcher facility ELSA of the University of Bonn. They can largely be extended to other boundary conditions and thus, can be consulted for new accelerator layouts.

  20. Electron spectroscopy studies of argon K-shell excitation and vacancy cascades

    International Nuclear Information System (INIS)

    Southworth, S.H.; MacDonald, M.A.; LeBrun, T.; Azuma, Y.; Cooper, J.W.

    1995-01-01

    Electron spectroscopy combined with tunable synchrotron radiation has been used for studies of Ar K-shell excitation and vacancy decay processes. In addition, electrons and fluorescent X-rays have been recorded in coincidence to select subsets of the ejected electron spectra. Examples are presented for Ar 1s photoelectrons and KLL and LMM Auger spectra

  1. Development and validation of the brief esophageal dysphagia questionnaire.

    Science.gov (United States)

    Taft, T H; Riehl, M; Sodikoff, J B; Kahrilas, P J; Keefer, L; Doerfler, B; Pandolfino, J E

    2016-12-01

    Esophageal dysphagia is common in gastroenterology practice and has multiple etiologies. A complication for some patients with dysphagia is food impaction. A valid and reliable questionnaire to rapidly evaluate esophageal dysphagia and impaction symptoms can aid the gastroenterologist in gathering information to inform treatment approach and further evaluation, including endoscopy. 1638 patients participated over two study phases. 744 participants completed the Brief Esophageal Dysphagia Questionnaire (BEDQ) for phase 1; 869 completed the BEDQ, Visceral Sensitivity Index, Gastroesophageal Reflux Disease Questionnaire, and Hospital Anxiety and Depression Scale for phase 2. Demographic and clinical data were obtained via the electronic medical record. The BEDQ was evaluated for internal consistency, split-half reliability, ceiling and floor effects, and construct validity. The BEDQ demonstrated excellent internal consistency, reliability, and construct validity. The symptom frequency and severity scales scored above the standard acceptable cutoffs for reliability while the impaction subscale yielded poor internal consistency and split-half reliability; thus the impaction items were deemed qualifiers only and removed from the total score. No significant ceiling or floor effects were found with the exception of 1 item, and inter-item correlations fell within accepted ranges. Construct validity was supported by moderate yet significant correlations with other measures. The predictive ability of the BEDQ was small but significant. The BEDQ represents a rapid, reliable, and valid assessment tool for esophageal dysphagia with food impaction for clinical practice that differentiates between patients with major motor dysfunction and mechanical obstruction. © 2016 John Wiley & Sons Ltd.

  2. Distorted wave calculations for electron loss process induced by bare ion impact on biological targets

    International Nuclear Information System (INIS)

    Monti, J.M.; Tachino, C.A.; Hanssen, J.; Fojón, O.A.; Galassi, M.E.; Champion, C.; Rivarola, R.D.

    2014-01-01

    Distorted wave models are employed to investigate the electron loss process induced by bare ions on biological targets. The two main reactions which contribute to this process, namely, the single electron ionization as well as the single electron capture are here studied. In order to further assess the validity of the theoretical descriptions used, the influence of particular mechanisms are studied, like dynamic screening for the case of electron ionization and energy deposition on the target by the impacting projectile for the electron capture one. Results are compared with existing experimental data. - Highlights: ► Distorted wave models are used to investigate ion-molecule collisions. ► Differential and total cross-sections for capture and ionization are evaluated. ► The influence of dynamic screening is determined. ► Capture reaction dominates the mean energy deposited by the projectile on the target

  3. The electronic structure of VO in its ground and electronically excited states: A combined matrix isolation and quantum chemical (MRCI) study

    International Nuclear Information System (INIS)

    Hübner, Olaf; Hornung, Julius; Himmel, Hans-Jörg

    2015-01-01

    The electronic ground and excited states of the vanadium monoxide (VO) molecule were studied in detail. Electronic absorption spectra for the molecule isolated in Ne matrices complement the previous gas-phase spectra. A thorough quantum chemical (multi-reference configuration interaction) study essentially confirms the assignment and characterization of the electronic excitations observed for VO in the gas-phase and in Ne matrices and allows the clarification of open issues. It provides a complete overview over the electronically excited states up to about 3 eV of this archetypical compound

  4. New pbysical methods used in the study of composition, electronic properties and surface phenomena of solid substances. I. Electronic spectroscopies

    International Nuclear Information System (INIS)

    Toderean, A; Ilonca, Gh.

    1981-01-01

    The discovery of different kinds of interactions between solids and fotonic, respectively electronic and ionic beams, leads to the development of many new, very sensitive, physical methods for the study of solids. This monograph tries to present some of these methods, useful in compositional analysis, in the study of electronic properties and of the surface processes of solid substances. This is done from the point of view both of physical phenomena underlying them and of the information obtainable with such methods. But the whole monograph is limited only to the methods based on the electronic properties of the elements existing in the solid probes studied and this paper presents only those of them in which the detected beam is an electronic one, like: ELS, DAPS, ILS, AES, AEAPS, INS, TSS, XPS and UPS. (authors)

  5. The Sydney Triage to Admission Risk Tool (START): A prospective validation study.

    Science.gov (United States)

    Ebker-White, Anja A; Bein, Kendall J; Dinh, Michael M

    2018-02-08

    The present study aims to prospectively validate the Sydney Triage to Admission Risk Tool (START) to predict ED disposition. This was a prospective validation study at two metropolitan EDs in Sydney, Australia. Consecutive triage encounters were observed by a trained researcher and START scores calculated. The primary outcome was patient disposition (discharge or inpatient admission) from the ED. Multivariable logistic regression was used to estimate area under curve of receiver operator characteristic (AUC ROC) for START scores as well as START score in combination with other variables such as frailty, general practitioner referral, overcrowding and major medical comorbidities. There were 894 patients analysed during the study period. The START score when applied to the data had AUC ROC of 0.80 (95% CI 0.77-0.83). The inclusion of other clinical variables identified at triage did not improve the overall performance of the model with an AUC ROC of 0.81 (95% CI 0.78-0.84) in the present study. The overall performance of the START tool with respect to model discrimination and accuracy has been prospectively validated. Further clinical trials are required to test the clinical effectiveness of the tool in improving patient flow and overall ED performance. © 2018 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  6. NATO Advanced Study Institute on Superconducting Electronics

    CERN Document Server

    Nisenhoff, Martin; Superconducting Electronics

    1989-01-01

    The genesis of the NATO Advanced Study Institute (ASI) upon which this volume is based, occurred during the summer of 1986 when we came to the realization that there had been significant progress during the early 1980's in the field of superconducting electronics and in applications of this technology. Despite this progress, there was a perception among many engineers and scientists that, with the possible exception of a limited number of esoteric fundamental studies and applications (e.g., the Josephson voltage standard or the SQUID magnetometer), there was no significant future for electronic systems incorporating superconducting elements. One of the major reasons for this perception was the aversion to handling liquid helium or including a closed-cycle helium liquefier. In addition, many critics felt that IBM's cancellation of its superconducting computer project in 1983 was "proof" that superconductors could not possibly compete with semiconductors in high-speed signal processing. From our persp...

  7. Validation of physical activity instruments: Black Women's Health Study.

    Science.gov (United States)

    Carter-Nolan, Pamela L; Adams-Campbell, Lucile L; Makambi, Kepher; Lewis, Shantell; Palmer, Julie R; Rosenberg, Lynn

    2006-01-01

    Few studies have reported on the validity of physical activity measures in African Americans. The present study was designed to determine the validity of a self-administered physical activity questionnaire (PAQ) that was used in a large prospective study of African American women in the United States against an accelerometer (actigraph), an objective assessment of movement, and a seven-day activity diary. The study was conducted among 101 women enrolled in the Black Women's Health Study (BWHS) cohort who resided in the Washington, DC, metropolitan area, representing 11.2% (101/900) of this sample. Physical activity levels were obtained from the parent BWHS PAQ (eg, 1997 and 1999) and repeated in the present study. This information entailed hours per week of participation in walking for exercise, hours per week of moderate activity (eg, housework, gardening, and bowling), and hours per week of strenuous activity (eg, basketball, swimming, running, and aerobics) during the previous year. The participants were required to wear actigraphs for seven days and then record their physical activities in their diaries (seven-day physical activity diary) during this time. The diaries were used to record the amount and pattern of daily energy expenditure. Significant positive correlations were seen between the BWHS PAQ and the actigraph for total activity, r=.28; walking, r=.26; and vigorous activity, r=.40, PPAQ also demonstrated significant correlations for total (r=0.42, PPAQ is a useful measure of physical activity in the BWHS cohort and thus has utility in prospective epidemiologic research.

  8. Electron holography study on the microstructure of magnetic tunnelling junctions

    International Nuclear Information System (INIS)

    Xu, Q.Y.; Wang, Y.G.; You, B.; Du, J.; Hu, A.; Zhang, Z.

    2004-01-01

    Electron holography was applied to study the microstructure evolution of magnetic tunnelling junctions (MTJs) CoFe/AlO x /Co annealed at different temperatures. A mean inner potential barrier was observed in the as-deposited MTJ sample, while it was changed to a potential well after a 200 deg. C or a 400 deg. C annealing. It is suggested that the oxygen atoms were redistributed during the annealing, which left metallic atoms acting as acceptors to confine the electrons, leading to the decrease of the potential of the AlO x barrier layer. The results suggest that the electron holography may be a useful tool for the study of the microstructure of amorphous materials

  9. A self-heating study on multi-finger AlGaN/GaN high electron mobility transistors

    International Nuclear Information System (INIS)

    Yang Liyuan; Ai Shan; Chen Yonghe; Cao Mengyi; Zhang Kai; Ma Xiaohua; Hao Yue

    2013-01-01

    Self-heating in multi-finger AlGaN/GaN high-electron-mobility transistors (HEMTs) is investigated by measurements and modeling of device junction temperature under steady-state operation. Measurements are carried out using micro-Raman scattering to obtain the detailed and accurate temperature distribution of the device. The device peak temperature corresponds to the high field region at the drain side of gate edge. The channel temperature of the device is modeled using a combined electro-thermal model considering 2DEG transport characteristics and the Joule heating power distribution. The results reveal excellent correlation to the micro-Raman measurements, validating our model for the design of better cooled structures. Furthermore, the influence of layout design on the channel temperature of multi-finger AlGaN/GaN HEMTs is studied using the proposed electro-thermal model, allowing for device optimization. (semiconductor devices)

  10. DEVELOPING VISUAL PRESENTATION ATTITUDE RUBRIC: VALIDITY AND RELIABILITY STUDY

    OpenAIRE

    ATEŞ, Hatice KADIOĞLU; ADA, Sefer; BAYSAL, Z. Nurdan

    2015-01-01

    Abstract The aim of this study is to develop visual presentation attitude rubric which is valid and reliable for the 4th grade students. 218 students took part in this study from Engin Can Güre which located in Istanbul, Esenler. While preparing this assessment tool with 34 criterias , 6 university lecturers view have been taken who are experts in their field. The answer key sheet has 4 (likert )type options. The rubric has been first tested by Kaiser-Meyer Olkin and Bartletts tests an...

  11. Estimating morbidity rates from electronic medical records in general practice: evaluation of a grouping system.

    NARCIS (Netherlands)

    Biermans, M.C.J.; Verheij, R.A.; Bakker, D.H. de; Zielhuis, G.A.; Vries Robbé, P.F. de

    2008-01-01

    Objectives: In this study, we evaluated the internal validity of EPICON, an application for grouping ICPCcoded diagnoses from electronic medical records into episodes of care. These episodes are used to estimate morbidity rates in general practice. Methods: Morbidity rates based on EPICON were

  12. Progress on electron cloud effects calculations for the FNAL main injector

    International Nuclear Information System (INIS)

    Furman, Miguel A; Sonnad, Kiran G.; Furman, Miguel A.; Vay, Jean-Luc

    2008-01-01

    We have studied the response of the beam to an electron cloud for the Fermilab Main Injector using the Quasistatic Model [1] implemented into the particle-in-cell code Warp [2]. Specifically, we have addressed the effects due to varying the beam intensity, electron cloud density and chromaticity. In addition, we have estimated the contribution to emittance evolution due to beam space-charge effects. We have carried out a comparison between how the beam responds at injection energy and at top energy. We also present some results on the validation of the computational model, and report on progress towards improving the computational model

  13. Studying Validity of Single-Fluid Model in Inertial Confinement Fusion

    International Nuclear Information System (INIS)

    Gu Jian-Fa; Fan Zheng-Feng; Dai Zhen-Sheng; Ye Wen-Hua; Pei Wen-Bing; Zhu Shao-Ping

    2014-01-01

    The validity of single-fluid model in inertial confinement fusion simulations is studied by comparing the results of the multi- and single-fluid models. The multi-fluid model includes the effects of collision and interpenetration between fluid species. By simulating the collision of fluid species, steady-state shock propagation into the thin DT gas and expansion of hohlraum Au wall heated by lasers, the results show that the validity of single-fluid model is strongly dependent on the ratio of the characteristic length of the simulated system to the particle mean free path. When the characteristic length L is one order larger than the mean free path λ, the single-fluid model's results are found to be in good agreement with the multi-fluid model's simulations, and the modeling of single-fluid remains valid. If the value of L/λ is lower than 10, the interpenetration between fluid species is significant, and the single-fluid simulations show some unphysical results; while the multi-fluid model can describe well the interpenetration and mix phenomena, and give more reasonable results. (physics of gases, plasmas, and electric discharges)

  14. Multiprofissional electronic protocol in ophtalmology with enfasis in strabismus.

    Science.gov (United States)

    Ribeiro, Christie Graf; Moreira, Ana Tereza Ramos; Pinto, José Simão DE Paula; Malafaia, Osvaldo

    2016-01-01

    to create and validate an electronic database in ophthalmology focused on strabismus, to computerize this database in the form of a systematic data collection software named Electronic Protocol, and to incorporate this protocol into the Integrated System of Electronic Protocols (SINPE(c)). this is a descriptive study, with the methodology divided into three phases: (1) development of a theoretical ophthalmologic database with emphasis on strabismus; (2) computerization of this theoretical ophthalmologic database using SINPE(c) and (3) interpretation of the information with demonstration of results to validate the protocol. We inputed data from the charts of fifty patients with known strabismus through the Electronic Protocol for testing and validation. the new electronic protocol was able to store information regarding patient history, physical examination, laboratory exams, imaging results, diagnosis and treatment of patients with ophthalmologic diseases, with emphasis on strabismus. We included 2,141 items in this master protocol and created 20 new specific electronic protocols for strabismus, each with its own specifics. Validation was achieved through correlation and corroboration of the symptoms and confirmed diagnoses of the fifty included patients with the diagnostic criteria for the twenty new strabismus protocols. a new, validated electronic database focusing on ophthalmology, with emphasis on strabismus, was successfully created through the standardized collection of information, and computerization of the database using proprietary software. This protocol is ready for deployment to facilitate data collection, sorting and application for practitioners and researchers in numerous specialties. criar uma base eletrônica de dados em oftalmologia com ênfase em estrabismo através da coleta padronizada de informações. Informatizar esta base sob a forma de software para a coleta sistemática de dados chamado "Protocolo Eletrônico" e incorporar este

  15. The validated sun exposure questionnaire

    DEFF Research Database (Denmark)

    Køster, B; Søndergaard, J; Nielsen, J B

    2017-01-01

    Few questionnaires used in monitoring sun-related behavior have been tested for validity. We established criteria validity of a developed questionnaire for monitoring population sun-related behavior. During May-August 2013, 664 Danes wore a personal electronic UV-dosimeter for one week...... that measured the outdoor time and dose of erythemal UVR exposure. In the following week, they answered a questionnaire on their sun-related behavior in the measurement week. Outdoor time measured by dosimetry correlated strongly with both outdoor time and the developed exposure scale measured...... in the questionnaire. Exposure measured in SED by dosimetry correlated strongly with the exposure scale. In a linear regression model of UVR (SED) received, 41 percent of the variation was explained by skin type, age, week of participation and the exposure scale, with the exposure scale as the main contributor...

  16. Optimization of power output and study of electron beam energy spread in a Free Electron Laser oscillator

    International Nuclear Information System (INIS)

    Abramovich, A.; Pinhasi, Y.; Yahalom, A.; Bar-Lev, D.; Efimov, S.; Gover, A.

    2001-01-01

    Design of a multi-stage depressed collector for efficient operation of a Free Electron Laser (FEL) oscillator requires knowledge of the electron beam energy distribution. This knowledge is necessary to determine the voltages of the depressed collector electrodes that optimize the collection efficiency and overall energy conversion efficiency of the FEL. The energy spread in the electron beam is due to interaction in the wiggler region, as electrons enter the interaction region at different phases relative to the EM wave. This interaction can be simulated well by a three-dimensional simulation code such as FEL3D. The main adjustable parameters that determine the electron beam energy spread after interaction are the e-beam current, the initial beam energy, and the quality factor of the resonator out-coupling coefficient. Using FEL3D, we study the influence of these parameters on the available radiation power and on the electron beam energy distribution at the undulator exit. Simulations performed for I=1.5 A, E=1.4 MeV, L=20% (Internal loss factor) showed that the highest radiated output power and smallest energy spread are attained for an output coupler transmission coefficient T m congruent with 30%

  17. Guiding-center equations for electrons in ultraintense laser fields

    International Nuclear Information System (INIS)

    Moore, J.E.; Fisch, N.J.

    1994-01-01

    The guiding-center equations are derived for electrons in arbitrarily intense laser fields also subject to external fields and ponderomotive forces. Exhibiting the relativistic mass increase of the oscillating electrons, a simple frame-invariant equation is shown to govern the behavior of the electrons for sufficiently weak background fields and ponderomotive forces. The parameter regime for which such a formulation is valid is made precise, and some predictions of the equation are checked by numerical simulation

  18. A Cross-Validation Study of the School Attitude Assessment Survey (SAAS).

    Science.gov (United States)

    McCoach, D. Betsy

    Factors commonly associated with underachievement in the research literature include low self-concept, low self-motivation/self-regulation, negative attitude toward school, and negative peer influence. This study attempts to isolate these four factors within a secondary school population. The purpose of the study was to design a valid and reliable…

  19. Social Media Addiction Scale-Student Form: The Reliability and Validity Study

    Science.gov (United States)

    Sahin, Cengiz

    2018-01-01

    The purpose of this study is to develop a valid and reliable measurement tool to determine the social media addictions of secondary school, high school and university students. 998 students participated in the study. 476 students from secondary schools, high schools and universities participated in the first application during which the…

  20. An analysis of electronic document management in oncology care.

    Science.gov (United States)

    Poulter, Thomas; Gannon, Brian; Bath, Peter A

    2012-06-01

    In this research in progress, a reference model for the use of electronic patient record (EPR) systems in oncology is described. The model, termed CICERO, comprises technical and functional components, and emphasises usability, clinical safety and user acceptance. One of the functional components of the model-an electronic document and records management (EDRM) system-is monitored in the course of its deployment at a leading oncology centre in the UK. Specifically, the user requirements and design of the EDRM solution are described.The study is interpretative and forms part a wider research programme to define and validate the CICERO model. Preliminary conclusions confirm the importance of a socio-technical perspective in Onco-EPR system design.

  1. The Prediction of Training Proficiency in Firefighters: A Study of Predictive Validity in Spain

    Directory of Open Access Journals (Sweden)

    Alfredo Berges

    2018-02-01

    Full Text Available The present study provides results of criterion validity in the selection of firefighters in Spain. The predictors were cognitive skills, job knowledge, and physical aptitudes, and the criterion was training proficiency. The process involves 639 candidates, but only 44 complete successfully the selection process. Our results support previous evidence showing that general cognitive ability is the best predictor of training proficiency, with an operational validity of .57. With respect to the other predictors, job knowledge presented an operational validity of .55 and physical tests of .49. In addition, multiple regression analysis showed that cognitive aptitude explains 33% of the variance, but when physical aptitudes are included the explained variance increases to 50%. If we also add job knowledge, explained variance increases to 55%. Our study offers recent results of criterion validity in a barely investigated job, gathered in a country other than the one where prior research had been carried out.

  2. Electronic transport coefficients from ab initio simulations and application to dense liquid hydrogen

    International Nuclear Information System (INIS)

    Holst, Bastian; French, Martin; Redmer, Ronald

    2011-01-01

    Using Kubo's linear response theory, we derive expressions for the frequency-dependent electrical conductivity (Kubo-Greenwood formula), thermopower, and thermal conductivity in a strongly correlated electron system. These are evaluated within ab initio molecular dynamics simulations in order to study the thermoelectric transport coefficients in dense liquid hydrogen, especially near the nonmetal-to-metal transition region. We also observe significant deviations from the widely used Wiedemann-Franz law, which is strictly valid only for degenerate systems, and give an estimate for its valid scope of application toward lower densities.

  3. Study of γ-irradiated lithographic polymers by electron spin resonance and electron nuclear double resonance

    International Nuclear Information System (INIS)

    Schlick, S.; Kevan, L.

    1982-01-01

    The room temperature gamma irradiation degradation of the lithographic polymers, poly(methylmethacrylate) (PMMA), poly(methyl-α-chloroacrylate) (PMCA), poly(methyl-α-fluoroacrylate) (PMFA), and poly(methylacrylonitrile) (PMCN), have been studied by electron spin resonance and electron nuclear double resonance (ENDOR) to assess their molecular degradation processes of relevance to electron beam lithography. Two classes of radicals are found, chain radicals and chain scission radicals. PMMA and PMCA mainly form chain scission radicals consistent with degradation while for PMCN the resolution is poorer, and this is only probable. PMFA forms mainly chain radicals consistent with predominant crosslinking. The total radical yield is greatest in PMCA and PMCN. ENDOR is used to assess the compactness of the radiation degradation region for PMMA and PMCA and hence the potential resolution of the resist; this appears to be about the same for these methacrylate polymers

  4. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  5. An Empirical Study of Logistics Organization, Electronic Linkage, and Performance

    Science.gov (United States)

    1993-01-01

    Anvari, M., "Electronic Data Interchange and Inventories," International Journal of Production Economics , 26, 1-3 (1992), 135-143. Baker, R. H., EDI: What...Electronic Data Interchange -- A Study of Norwegian Freight Forwarders Using EDI," International Journal of Production Economics , 24 (1991), 91-101. Henry, G

  6. Electron-beam generated porous dextran gels: experimental and quantum chemical studies.

    Science.gov (United States)

    Naumov, Sergej; Knolle, Wolfgang; Becher, Jana; Schnabelrauch, Matthias; Reichelt, Senta

    2014-06-01

    The aim of this work was to investigate the reaction mechanism of electron-beam generated macroporous dextran cryogels by quantum chemical calculation and electron paramagnetic resonance measurements. Electron-beam radiation was used to initiate the cross-linking reaction of methacrylated dextran in semifrozen aqueous solutions. The pore morphology of the resulting cryogels was visualized by scanning electron microscopy. Quantum chemical calculations and electron paramagnetic resonance studies provided information on the most probable reaction pathway and the chain growth radicals. The most probable reaction pathway was a ring opening reaction and the addition of a C-atom to the double-bond of the methacrylated dextran molecule. First detailed quantum chemical calculation on the reaction mechanism of electron-beam initiated cross-linking reaction of methacrylated dextran are presented.

  7. Ab initio study of hot electrons in GaAs

    OpenAIRE

    Bernardi, Marco; Vigil-Fowler, Derek; Ong, Chin Shen; Neaton, Jeffrey B.; Louie, Steven G.

    2015-01-01

    Hot carrier dynamics critically impacts the performance of electronic, optoelectronic, photovoltaic, and plasmonic devices. Hot carriers lose energy over nanometer lengths and picosecond timescales and thus are challenging to study experimentally, whereas calculations of hot carrier dynamics are cumbersome and dominated by empirical approaches. In this work, we present ab initio calculations of hot electrons in gallium arsenide (GaAs) using density functional theory and many-body perturbation...

  8. Experimental study of parametric dependence of electron-scale turbulence in a spherical tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Y.; Guttenfelder, W.; Kaye, S. M.; Mazzucato, E.; Bell, R. E.; Diallo, A.; LeBlanc, B. P. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Domier, C. W.; Lee, K. C. [University of California at Davis, Davis, California 95616 (United States); Smith, D. R. [University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States); Yuh, H. [Nova Photonics, Inc., Princeton, New Jersey 08540 (United States)

    2012-05-15

    Electron-scale turbulence is predicted to drive anomalous electron thermal transport. However, experimental study of its relation with transport is still in its early stage. On the National Spherical Tokamak Experiment (NSTX), electron-scale density fluctuations are studied with a novel tangential microwave scattering system with high radial resolution of {+-}2 cm. Here, we report a study of parametric dependence of electron-scale turbulence in NSTX H-mode plasmas. The dependence on density gradient is studied through the observation of a large density gradient variation in the core induced by an edge localized mode (ELM) event, where we found the first clear experimental evidence of density gradient stabilization of electron-gyro scale turbulence in a fusion plasma. This observation, coupled with linear gyro-kinetic calculations, leads to the identification of the observed instability as toroidal electron temperature gradient (ETG) modes. It is observed that longer wavelength ETG modes, k{sub Up-Tack }{rho}{sub s} Less-Than-Or-Equivalent-To 10 ({rho}{sub s} is the ion gyroradius at electron temperature and k{sub Up-Tack} is the wavenumber perpendicular to local equilibrium magnetic field), are most stabilized by density gradient, and the stabilization is accompanied by about a factor of two decrease in electron thermal diffusivity. Comparisons with nonlinear ETG gyrokinetic simulations show ETG turbulence may be able to explain the experimental electron heat flux observed before the ELM event. The collisionality dependence of electron-scale turbulence is also studied by systematically varying plasma current and toroidal field, so that electron gyroradius ({rho}{sub e}), electron beta ({beta}{sub e}), and safety factor (q{sub 95}) are kept approximately constant. More than a factor of two change in electron collisionality, {nu}{sub e}{sup *}, was achieved, and we found that the spectral power of electron-scale turbulence appears to increase as {nu}{sub e}{sup *} is

  9. Monte Carlo simulations of secondary electron emission due to ion beam milling

    Energy Technology Data Exchange (ETDEWEB)

    Mahady, Kyle [Univ. of Tennessee, Knoxville, TN (United States); Tan, Shida [Intel Corp., Santa Clara, CA (United States); Greenzweig, Yuval [Intel Israel Ltd., Haifa (Israel); Livengood, Richard [Intel Corp., Santa Clara, CA (United States); Raveh, Amir [Intel Israel Ltd., Haifa (Israel); Fowlkes, Jason D. [Univ. of Tennessee, Knoxville, TN (United States); Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rack, Philip [Univ. of Tennessee, Knoxville, TN (United States); Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-07-01

    We present a Monte Carlo simulation study of secondary electron emission resulting from focused ion beam milling of a copper target. The basis of this study is a simulation code which simulates ion induced excitation and emission of secondary electrons, in addition to simulating focused ion beam sputtering and milling. This combination of features permits the simulation of the interaction between secondary electron emission, and the evolving target geometry as the ion beam sputters material. Previous ion induced SE Monte Carlo simulation methods have been restricted to predefined target geometries, while the dynamic target in the presented simulations makes this study relevant to image formation in ion microscopy, and chemically assisted ion beam etching, where the relationship between sputtering, and its effects on secondary electron emission, is important. We focus on a copper target, and validate our simulation against experimental data for a range of: noble gas ions, ion energies, ion/substrate angles and the energy distribution of the secondary electrons. We then provide a detailed account of the emission of secondary electrons resulting from ion beam milling; we quantify both the evolution of the yield as high aspect ratio valleys are milled, as well as the emission of electrons within these valleys that do not escape the target, but which are important to the secondary electron contribution to chemically assisted ion induced etching.

  10. Validation of traffic-related air pollution exposure estimates for long-term studies

    NARCIS (Netherlands)

    Van Roosbroeck, S.

    2007-01-01

    This thesis describes a series of studies that investigate the validity of using outdoor concentrations and/or traffic-related indicator exposure variables as a measure for exposure assessment in epidemiological studies on the long-term effect of traffic-related air pollution. A pilot study was

  11. Study of fast electrons from hard-X radiation; Etude des electrons rapides a partir du rayonnement X-dur

    Energy Technology Data Exchange (ETDEWEB)

    Arslanbekov, R.

    1995-12-19

    The goal of this thesis is the study of fast electron dynamics by means of the hard X-ray diagnosis installed in TORE SUPRA and numerical simulations. Fast electrons are generated in the plasma in the presence of the injected lower hybrid (LH) waves. Two aspects are studied in detail: the lower hybrid wave propagation and absorption in a periodically perturbed media and 2-D Fokker-Planck modelling of the fast electron dynamics in the presence of the LH power. Ripple effects on lower hybrid wave propagation and absorption are investigated using the ray tracing technique. A cylindrical equilibrium is first studied and a strong modification of the ray dynamics is predicted. Calculations are carried out in a real toroidal geometry corresponding to TORE SUPRA. It is shown that the lack of toroidal axisymmetry of the magnetic field may result in a modification of the ray evolution even if the global ray evolution is governed by the larger poloidal inhomogeneity. Simulation of LH experiments are performed for TORE SUPRA tokamak which has a large magnetic ripple (7% at the plasma edge). By considering ripple perturbation in LH current drive simulations, a better agreement is found with experimental results, in particular with the hard-X spectra and the current density profiles. In the second part of the thesis, a 2-D modeling of the fast electron dynamics in the velocity phase space is considered, based on the 2-D relativistic electron Fokker-Planck equation. Electron distribution functions obtained are used to calculate non-thermal Bremsstrahlung emission for different TORE SUPRA shots in a wide range of experimental conditions. (J.S.). 168 refs., 93 figs., 1 tab., 3 appendix.

  12. Correlated electronic structure of CeN

    Energy Technology Data Exchange (ETDEWEB)

    Panda, S.K., E-mail: swarup.panda@physics.uu.se [Department of Physics and Astronomy, Uppsala University, P.O. Box 516, SE-751 20 Uppsala (Sweden); Di Marco, I. [Department of Physics and Astronomy, Uppsala University, P.O. Box 516, SE-751 20 Uppsala (Sweden); Delin, A. [Department of Physics and Astronomy, Uppsala University, P.O. Box 516, SE-751 20 Uppsala (Sweden); KTH Royal Institute of Technology, School of Information and Communication Technology, Department of Materials and Nano Physics, Electrum 229, SE-164 40 Kista (Sweden); KTH Royal Institute of Technology, Swedish e-Science Research Center (SeRC), SE-100 44 Stockholm (Sweden); Eriksson, O., E-mail: olle.eriksson@physics.uu.se [Department of Physics and Astronomy, Uppsala University, P.O. Box 516, SE-751 20 Uppsala (Sweden)

    2016-04-15

    Highlights: • The electronic structure of CeN is studied within the GGA+DMFT approach using SPTF and Hubbard I approximation. • 4f spectral functions from SPTF and Hubbard I are coupled to explain the various spectroscopic manifestations of CeN. • The calculated XPS and BIS spectra show good agreement with the corresponding experimental spectra. • The contribution of the various l-states and the importance of cross-sections for the photoemission process are analyzed. - Abstract: We have studied in detail the electronic structure of CeN including spin orbit coupling (SOC) and electron–electron interaction, within the dynamical mean-field theory combined with density-functional theory in generalized gradient approximation (GGA+DMFT). The effective impurity problem has been solved through the spin-polarized T-matrix fluctuation-exchange (SPTF) solver and the Hubbard I approximation (HIA). The calculated l-projected atomic partial densities of states and the converged potential were used to obtain the X-ray-photoemission-spectra (XPS) and Bremstrahlung Isochromat spectra (BIS). Following the spirit of Gunnarsson–Schonhammer model, we have coupled the SPTF and HIA 4f spectral functions to explain the various spectroscopic manifestations of CeN. Our computed spectra in such a coupled scheme explain the experimental data remarkably well, establishing the validity of our theoretical model in analyzing the electronic structure of CeN. The contribution of the various l-states in the total spectra and the importance of cross sections are also analyzed in detail.

  13. Neo-Institutional Approach to the Study of Electronic Government

    Directory of Open Access Journals (Sweden)

    Yan I. Vaslavskiy

    2016-01-01

    Full Text Available The article is devoted to the neo-institutional approach as a methodological basis in the study of electronic government. In this article substantiates the choice of neo-institutional approach to the study of the processes of implementation of information and communication technologies in the activity of state institutions, analyzes the differences of neoinstitutionalism from traditional institutional approach, considers the features of the different directions of neo-institutionalism, namely sociological, historical and rational choice theory. Attention is paid to the reasons for the renewed interest in political institutions in political science. The article emphasizes the importance of considering the electronic government as an institution, and the conditions for its implementation in the Russian political system as the institutional environment. The authors pay special attention to the variety of sociological neo-institutionalism, used, in addition to political science in sociology of organizations. The article substantiates the value of using sociological institutionalism to explore the electronic government based on a comparative analysis of e-government projects in Russia and abroad and explores its heuristic capabilities. It examines the impact of the system of norms and values of the institutional environment on the processes of formation and development of electronic government in Russia. The research capacity of this theory is due to the fact that it allows us to trace the reasons for copying and replication of inefficient practices and organizational and management schemes, to identify the factors impeding innovation use by the state of electronic interaction technologies. It is emphasized that the use of the theory of institutional isomorphism is useful in the sphere of implementation of electronic technologies, in which a key role play pluralism, horizontal managerial communication, inter-agency coordination.

  14. Design for low-power and reliable flexible electronics

    Science.gov (United States)

    Huang, Tsung-Ching (Jim)

    Flexible electronics are emerging as an alternative to conventional Si electronics for large-area low-cost applications such as e-paper, smart sensors, and disposable RFID tags. By utilizing inexpensive manufacturing methods such as ink-jet printing and roll-to-roll imprinting, flexible electronics can be made on low-cost plastics just like printing a newspaper. However, the key elements of exible electronics, thin-film transistors (TFTs), have slower operating speeds and less reliability than their Si electronics counterparts. Furthermore, depending on the material property, TFTs are usually mono-type -- either p- or n-type -- devices. Making air-stable complementary TFT circuits is very challenging and not applicable to most TFT technologies. Existing design methodologies for Si electronics, therefore, cannot be directly applied to exible electronics. Other inhibiting factors such as high supply voltage, large process variation, and lack of trustworthy device modeling also make designing larger-scale and robust TFT circuits a significant challenge. The major goal of this dissertation is to provide a viable solution for robust circuit design in exible electronics. I will first introduce a reliability simulation framework that can predict the degraded TFT circuits' performance under bias-stress. This framework has been validated using the amorphous-silicon (a-Si) TFT scan driver for TFT-LCD displays. To reuse the existing CMOS design ow for exible electronics, I propose a Pseudo-CMOS cell library that can make TFT circuits operable under low supply voltage and which has post-fabrication tunability for reliability and performance enhancement. This cell library has been validated using 2V self-assembly-monolayer (SAM) organic TFTs with a low-cost shadow-mask deposition process. I will also demonstrate a 3-bit 1.25KS/s Flash ADC in a-Si TFTs, which is based on the proposed Pseudo-CMOS cell library, and explore more possibilities in display, energy, and sensing

  15. Studies of electron correlation in the photoionization process

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Richard Allen [Univ. of California, Berkeley, CA (United States)

    1979-03-01

    Electron correlation is a result of the interaction of two or more electrons confined in a region of space, and may conveniently be treated under the formalism of configuration interaction (CI). Photoionization provides a rather direct experimental method for studying configuration interaction. The types of CI involved in the photoionization process can be divided into three categories: initial state configuration interaction (ISCI), final ionic state configuration interaction (FISCI), and continuum state configuration interaction (CSCI). This thesis deals with experimental studies which reveal how the various types of CI may become manifested in photoionization. The experimental methods utilized in this work are photoelectron spectroscopy (PES), electron impact spectroscopy (EIS), and time-resolved fluorescence spectroscopy. The EIS was carried out following the discovery that the UV lamp on a Perkin-Elmer photoelectron spectrometer could be utilized as a source of low energy electrons. The time-resolved fluorescence work utilized both the tunability and the time structure of the radiation available at the Stanford Synchrotron Radiation Laboratory (SSRL). A commercial photoelectron spectrometer equipped with a conventional UV lamp (Hei, Nei) was employed for some of the PES studies, and a novel time-of-flight photoelectron spectrometer was developed for the PES work performed using synchrotron radiation. The PES of Ba, Sm, Eu, and Yb was studied using both Hei (22.22 eV) and Nei (16.85 eV) radiation. Satellite structure observed in these spectra using Nei (and for Yb, Hei also) radiation could be satisfactorily explained by ISCI alone. The Hei spectra of Sm, Eu, and, in particular, Ba showed dramatic changes in the satellite population which could only be explained by a new mechanism, autoionization, which is a special form of CSCI. The detailed nature of this mechanism was explored in Ba using synchrotron radiation. It was found that the autoionizing level decays

  16. Practical calculation of amplitudes for electron-impact ionization

    International Nuclear Information System (INIS)

    McCurdy, C. William; Horner, Daniel A.; Rescigno, Thomas N.

    2001-01-01

    An integral expression that is formally valid only for short-range potentials is applied to the problem of calculating the amplitude for electron-impact ionization. It is found that this expression provides a practical and accurate path to the calculation of singly differential cross sections for electron-impact ionization. Calculations are presented for the Temkin-Poet and collinear models for ionization of hydrogen by electron impact. An extension of the finite-element approach using the discrete-variable representation, appropriate for potentials with discontinuous derivatives like the Temkin-Poet interaction, is also presented

  17. The child-Langmuir limit for semiconductors: a numerical validation

    International Nuclear Information System (INIS)

    Caceres, M.J.; Carrillo, J.A.; Degond, P.

    2002-01-01

    The Boltzmann-Poisson system modeling the electron flow in semiconductors is used to discuss the validity of the Child-Langmuir asymptotics. The scattering kernel is approximated by a simple relaxation time operator. The Child-Langmuir limit gives an approximation of the current-voltage characteristic curves by means of a scaling procedure in which the ballistic velocity is much larger that the thermal one. We discuss the validity of the Child-Langmuir regime by performing detailed numerical comparisons between the simulation of the Boltzmann-Poisson system and the Child-Langmuir equations in test problems. (authors)

  18. Electronic Dietary Intake Assessment (e-DIA): relative validity of a mobile phone application to measure intake of food groups.

    Science.gov (United States)

    Rangan, Anna M; Tieleman, Laurissa; Louie, Jimmy C Y; Tang, Lie Ming; Hebden, Lana; Roy, Rajshri; Kay, Judy; Allman-Farinelli, Margaret

    2016-06-01

    Automation of dietary assessment can reduce limitations of established methodologies, by alleviating participant and researcher burden. Designed as a research tool, the electronic Dietary Intake Assessment (e-DIA) is a food record in mobile phone application format. The present study aimed to examine the relative validity of the e-DIA with the 24-h recall method to estimate intake of food groups. A sample of eighty university students aged 19-24 years recorded 5 d of e-DIA and 3 d of recall within this 5-d period. The three matching days of dietary data were used for analysis. Food intake data were disaggregated and apportioned to one of eight food groups. Median intakes of food groups were similar between the methods, and strong correlations were found (mean: 0·79, range: 0·69-0·88). Cross-classification by tertiles produced a high level of exact agreement (mean: 71 %, range: 65-75 %), and weighted κ values were moderate to good (range: 0·54-0·71). Although mean differences (e-DIA-recall) were small (range: -13 to 23 g), limits of agreement (LOA) were relatively large (e.g. for vegetables, mean difference: -4 g, LOA: -159 to 151 g). The Bland-Altman plots showed robust agreement, with minimum bias. This analysis supports the use of e-DIA as an alternative to the repeated 24-h recall method for ranking individuals' food group intake.

  19. Design and dosimetry of a few leaf electron collimator for energy modulated electron therapy

    International Nuclear Information System (INIS)

    Al-Yahya, Khalid; Verhaegen, Frank; Seuntjens, Jan

    2007-01-01

    Despite the capability of energy modulated electron therapy (EMET) to achieve highly conformal dose distributions in superficial targets it has not been widely implemented due to problems inherent in electron beam radiotherapy such as planning dosimetry accuracy, and verification as well as a lack of systems for automated delivery. In previous work we proposed a novel technique to deliver EMET using an automated 'few leaf electron collimator' (FLEC) that consists of four motor-driven leaves fit in a standard clinical electron beam applicator. Integrated with a Monte Carlo based optimization algorithm that utilizes patient-specific dose kernels, a treatment delivery was incorporated within the linear accelerator operation. The FLEC was envisioned to work as an accessory tool added to the clinical accelerator. In this article the design and construction of the FLEC prototype that match our compact design goals are presented. It is controlled using an in-house developed EMET controller. The structure of the software and the hardware characteristics of the EMET controller are demonstrated. Using a parallel plate ionization chamber, output measurements were obtained to validate the Monte Carlo calculations for a range of fields with different energies and sizes. Further verifications were also performed for comparing 1-D and 2-D dose distributions using energy independent radiochromic films. Comparisons between Monte Carlo calculations and measurements of complex intensity map deliveries show an overall agreement to within ±3%. This work confirms our design objectives of the FLEC that allow for automated delivery of EMET. Furthermore, the Monte Carlo dose calculation engine required for EMET planning was validated. The result supports the potential of the prototype FLEC for the planning and delivery of EMET

  20. Installation and validation of MCNP-4A

    International Nuclear Information System (INIS)

    Marks, N.A.

    1997-01-01

    MCNP-4A is a multi-purpose Monte Carlo program suitable for the modelling of neutron, photon, and electron transport problems. It is a particularly useful technique when studying systems containing irregular shapes. MCNP has been developed over the last 25 years by Los Alamos, and is distributed internationally via RSIC at Oak Ridge. This document describes the installation of MCNP-4A (henceforth referred to as MCNP) on the Silicon Graphics workstation (bluey.ansto.gov.au). A limited number of benchmarks pertaining to fast and thermal systems were performed to check the installation and validate the code. The results are compared to deterministic calculations performed using the AUS neutronics code system developed at ANSTO. (author)

  1. Electronic nicotine delivery system (electronic cigarette) awareness, use, reactions and beliefs: a systematic review.

    Science.gov (United States)

    Pepper, Jessica K; Brewer, Noel T

    2014-09-01

    We sought to systematically review the literature on electronic nicotine delivery systems (ENDS, also called electronic cigarettes) awareness, use, reactions and beliefs. We searched five databases for articles published between 2006 and 1 July 2013 that contained variations of the phrases 'electronic cigarette', 'e-cigarette' and 'electronic nicotine delivery'. Of the 244 abstracts identified, we excluded articles not published in English, articles unrelated to ENDS, dissertation abstracts and articles without original data on prespecified outcomes. Two reviewers coded each article for ENDS awareness, use, reactions and beliefs. 49 studies met inclusion criteria. ENDS awareness increased from 16% to 58% from 2009 to 2011, and use increased from 1% to 6%. The majority of users were current or former smokers. Many users found ENDS satisfying, and some engaged in dual use of ENDS and other tobacco. No longitudinal studies examined whether ENDS serve as 'gateways' to future tobacco use. Common reasons for using ENDS were quitting smoking and using a product that is healthier than cigarettes. Self-reported survey data and prospective trials suggest that ENDS might help cigarette smokers quit, but no randomised controlled trials with probability samples compared ENDS with other cessation tools. Some individuals used ENDS to avoid smoking restrictions. ENDS use is expanding rapidly despite experts' concerns about safety, dual use and possible 'gateway' effects. More research is needed on effective public health messages, perceived health risks, validity of self-reports of smoking cessation and the use of different kinds of ENDS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Experimental study on generation of large area uniform electron beam

    International Nuclear Information System (INIS)

    Tang Ying; Yi Aiping; Liu Jingru; Qian Hang; Huang Xin; Yu Li; Su Jiancang; Ding Zhenjie; Ding Yongzhong; Yu Jianguo

    2007-01-01

    In the experiment of gas laser pumped by electron beam, large area uniform electron beam is important to generate high efficiency laser output. The experimental study on generation of large area uniform electron beam with SPG-200 pulsed power generator is introduced. SPG-200 is an all-solid-state components pulsed power generator based on SOS, and its open voltage is more than 350 kV. The cathode have the area of 24 mm x 294 mm, and the anode-cathode(A-C)gap spacing is adjustable from 0 to 49 mm. The electron beam of cathode emission is transported to the laser chamber through the diode pressure foil, which sepa-rates the vacuum chamber from the laser chamber. Velvet and graphite cathodes are studied, each generates large area electron beam. The diode parameters are presented, and the uniformity of e-beam is diagnosed. The experimental results show that the diode voltage of the graphite cathode is 240-280 kV, and the diode current is 0.7-1.8 kA. The diode voltage of the velvet cathode is 200-250 kV, and the diode current is 1.5-1.7 kA. The uniformity of the velvet cathode emission is better than that of the graphite cathode. (authors)

  3. Changes in electron precipitation inferred from spectra deduced from D region electron densities during a post--magnetic storm effect

    International Nuclear Information System (INIS)

    Montbriand, L.E.; Belrose, J.S.

    1976-01-01

    The occurrence of enhanced ionization after geomagnetic storms, commonly referred to as storm aftereffect, is investigated on the hypothesis that the enhancement is due to a 'drizzle' of energetic electrons from the radiation belts. The study utilized electron density-height profiles obtained from the partial reflection experiment at Ottawa and available information on the height profile of the steady state loss coefficient for energetic electron events in combination with the ion pair production treatments of Ress (1963) and Berger et al. (1974) to deduce two-component differential energy spectra of the electron drizzle. The period studied, December 13--20, 1970, was unique for examining poststorm effects in that the geomagnetic storm on December 14--15 was intense and brief, and it was preceded and followed by periods of geomagnetic calm. The results indicate that the drizzle deduced was minimal before the storm and on the storm day and maximized 2--3 days after the peak of the storm at a time when geomagnetic activity had returned to calm. The results also suggest that the spectrum was hardest shortly after the drizzle maximized. No satisfactory source for the enhanced ionization during the poststorm other than particle drizzle could be found that would produce both the magnitude and the diurnal variation of the effect observed, a conclusion which establishes the validity of the hypothesis made

  4. Electronic journals and scholarly communication: a citation and reference study

    Directory of Open Access Journals (Sweden)

    Stephen P. Harter

    1996-01-01

    Full Text Available The journal is fundamental to formal scholarly communication. This research reports highlights and preliminary findings from an empirical study of scholarly electronic journals. The purpose of the research is to assess the impact of electronic journals (e-journals on scholarly communication, by measuring the extent to which they are being cited in the literature, both print and electronic. The intent is to provide a snapshot of the impact e-journals were having on scholarly communication at a given point in time, roughly the end of 1995. This study provides one measure of that impact, specifically on the formal, as opposed to informal, communication process. The study also examines the forms in which scholars cite e-journals, the accuracy and completeness of citations to e-journals, and practical difficulties faced by scholars and researchers who wish to retrieve e-journals through the networks.

  5. Validation study of a web-based assessment of functional recovery after radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Vickers Andrew J

    2010-08-01

    Full Text Available Abstract Background Good clinical care of prostate cancer patients after radical prostatectomy depends on careful assessment of post-operative morbidities, yet physicians do not always judge patient symptoms accurately. Logistical problems associated with using paper questionnaire limit their use in the clinic. We have implemented a web-interface ("STAR" for patient-reported outcomes after radical prostatectomy. Methods We analyzed data on the first 9 months of clinical implementation to evaluate the validity of the STAR questionnaire to assess functional outcomes following radical prostatectomy. We assessed response rate, internal consistency within domains, and the association between survey responses and known predictors of sexual and urinary function, including age, time from surgery, nerve sparing status and co-morbidities. Results Of 1581 men sent an invitation to complete the instrument online, 1235 responded for a response rate of 78%. Cronbach's alpha was 0.84, 0.86 and 0.97 for bowel, urinary and sexual function respectively. All known predictors of sexual and urinary function were significantly associated with survey responses in the hypothesized direction. Conclusions We have found that web-based assessment of functional recovery after radical prostatectomy is practical and feasible. The instrument demonstrated excellent psychometric properties, suggested that validity is maintained when questions are transferred from paper to electronic format and when patients give responses that they know will be seen by their doctor and added to their clinic record. As such, our system allows ready implementation of patient-reported outcomes into routine clinical practice.

  6. Diagnosing viral and bacterial respiratory infections in acute COPD exacerbations by an electronic nose: a pilot study.

    Science.gov (United States)

    van Geffen, Wouter H; Bruins, Marcel; Kerstjens, Huib A M

    2016-06-16

    Respiratory infections, viral or bacterial, are a common cause of acute exacerbations of chronic obstructive pulmonary disease (AECOPD). A rapid, point-of-care, and easy-to-use tool distinguishing viral and bacterial from other causes would be valuable in routine clinical care. An electronic nose (e-nose) could fit this profile but has never been tested in this setting before. In a single-center registered trial (NTR 4601) patients admitted with AECOPD were tested with the Aeonose(®) electronic nose, and a diagnosis of viral or bacterial infection was obtained by bacterial culture on sputa and viral PCR on nose swabs. A neural network with leave-10%-out cross-validation was used to assess the e-nose data. Forty three patients were included. In the bacterial infection model, 22 positive cases were tested versus the negatives; and similarly 18 positive cases were tested in the viral infection model. The Aeonose was able to distinguish between COPD-subjects suffering from a viral infection and COPD patients without infection, showing an area under the curve (AUC) of 0.74. Similarly, for bacterial infections, an AUC of 0.72 was obtained. The Aeonose e-nose yields promising results in 'smelling' the presence or absence of a viral or bacterial respiratory infection during an acute exacerbation of COPD. Validation of these results using a new and large cohort is required before introduction into clinical practice.

  7. 78 FR 18353 - Guidance for Industry: Blood Establishment Computer System Validation in the User's Facility...

    Science.gov (United States)

    2013-03-26

    ... SUPPLEMENTARY INFORMATION section for electronic access to the guidance document. Submit electronic comments on... document entitled ``Guidance for Industry: Blood Establishment Computer System Validation in the User's... document to http://www.regulations.gov or written comments to the Division of Dockets Management (see...

  8. Study and realization of an electron linear accelerator. Dynamics of accelerated electrons; Etude et realisation d'un accelerateur lineaire d'electrons. Dynamique des electrons acceleres

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-04-01

    The theoretical characteristics of the electron linear accelerator are: 30 MeV for the energy W{sub S} and 250 mA for the peak current I{sub c}. The main utilization is the intense production of fast neutrons by the reactions ({gamma},n) and ({gamma},f) induced in a target of natural uranium by the accelerated electrons. In the first part of the thesis, relative to the study and the realization of the accelerator, a new equation of dispersion is established analytically when the guide is loaded with round-edged irises. The relation is compared with the equation established by CHU and Hansen, WALKINSHAW, KVASIL in the case of a guide loaded with flat-edged irises. The experimental and theoretical curves of dispersion are compared. The accuracy of every relation of dispersion is estimated. The second part of the thesis is relative to the theoretical study of the electrons dynamics in the guide; it allows the derivation of the parameters of the beam: dispersion of phase, energy, dispersion of energy and the relation W{sub S} = f (I{sub c}). The results relative to the first experiments are given and compared with the theoretical expectations. (author) [French] Les caracteristiques nominales theoriques de l'accelerateur lineaire d'electrons sont: 30 MeV pour l'energie W{sub S} et 250 mA pour le courant de crete I{sub c}. L'utilisation principale envisagee est la production de neutrons rapides par les reactions ({gamma},n) et ({gamma},f) induites dans une cible d'uranium naturel par les electrons acceleres. Dans la premiere partie de la these relative a l'elude et a la realisation de l'accelerateur, une nouvelle equation de dispersion (ou equation aux frequences) est etablie analytiquement pour un guide charge par des iris a bord rond. Cette relation est comparee a celles etablies par CHU et HANSEN, WALKINSHAW, KVASIL dans le cas du guide charge par des iris a bord plat. On compare les courbes de dispersion theoriques et experimentales et on evalue la precision de

  9. Design studies on high current and grid control electron gun

    International Nuclear Information System (INIS)

    Wang Jinnan; Lu Kun; Chi Yunlong; Zhou Zusheng

    2011-01-01

    Electron gun, the source of electrons, is a kind of ultrahigh vacuum device and plays an important role in different kind of accelerators. With the irradiation accelerator demands, describes the design studies on beam optics optimization. The simulation result shows that the beam current is above 5 A with cathode voltage of 80 kV and beam emittance, gun electric field and beam waist radius meet the accelerator needs. The electron gun manufactured and installed in the test stand, the conditioning and test will be done in the near future. (authors)

  10. 78 FR 5816 - Electronic Study Data Submission; Data Standard Support End Date

    Science.gov (United States)

    2013-01-28

    ...] Electronic Study Data Submission; Data Standard Support End Date AGENCY: Food and Drug Administration, HHS... Safety and Innovation Act (FDASIA) (Public Law 112- 144), requires electronic submission of drug and... comment, will specify the format required for such electronic submissions. The action announced in this...

  11. The role of low-energy electrons in focused electron beam induced deposition: four case studies of representative precursors

    Directory of Open Access Journals (Sweden)

    Rachel M. Thorman

    2015-09-01

    Full Text Available Focused electron beam induced deposition (FEBID is a single-step, direct-write nanofabrication technique capable of writing three-dimensional metal-containing nanoscale structures on surfaces using electron-induced reactions of organometallic precursors. Currently FEBID is, however, limited in resolution due to deposition outside the area of the primary electron beam and in metal purity due to incomplete precursor decomposition. Both limitations are likely in part caused by reactions of precursor molecules with low-energy (3, Pt(PF34, Co(CO3NO, and W(CO6. Through these case studies, it is evident that this combination of studies can provide valuable insight into potential mechanisms governing deposit formation in FEBID. Although further experiments and new approaches are needed, these studies are an important stepping-stone toward better understanding the fundamental physics behind the deposition process and establishing design criteria for optimized FEBID precursors.

  12. Electron beam collimation with a photon MLC for standard electron treatments

    Science.gov (United States)

    Mueller, S.; Fix, M. K.; Henzen, D.; Frei, D.; Frauchiger, D.; Loessl, K.; Stampanoni, M. F. M.; Manser, P.

    2018-01-01

    Standard electron treatments are currently still performed using standard or molded patient-specific cut-outs placed in the electron applicator. Replacing cut-outs and electron applicators with a photon multileaf collimator (pMLC) for electron beam collimation would make standard electron treatments more efficient and would facilitate advanced treatment techniques like modulated electron radiotherapy (MERT) and mixed beam radiotherapy (MBRT). In this work, a multiple source Monte Carlo beam model for pMLC shaped electron beams commissioned at a source-to-surface distance (SSD) of 70 cm is extended for SSDs of up to 100 cm and validated for several Varian treatment units with field sizes typically used for standard electron treatments. Measurements and dose calculations agree generally within 3% of the maximal dose or 2 mm distance to agreement. To evaluate the dosimetric consequences of using pMLC collimated electron beams for standard electron treatments, pMLC-based and cut-out-based treatment plans are created for a left and a right breast boost, a sternum, a testis and a parotid gland case. The treatment plans consist of a single electron field, either alone (1E) or in combination with two 3D conformal tangential photon fields (1E2X). For each case, a pMLC plan with similar treatment plan quality in terms of dose homogeneity to the target and absolute mean dose values to the organs at risk (OARs) compared to a cut-out plan is found. The absolute mean dose to an OAR is slightly increased for pMLC-based compared to cut-out-based 1E plans if the OAR is located laterally close to the target with respect to beam direction, or if a 6 MeV electron beam is used at an extended SSD. In conclusion, treatment plans using cut-out collimation can be replaced by plans of similar treatment plan quality using pMLC collimation with accurately calculated dose distributions.

  13. Assessment of bachelor's theses in a nursing degree with a rubrics system: Development and validation study.

    Science.gov (United States)

    González-Chordá, Víctor M; Mena-Tudela, Desirée; Salas-Medina, Pablo; Cervera-Gasch, Agueda; Orts-Cortés, Isabel; Maciá-Soler, Loreto

    2016-02-01

    Writing a bachelor thesis (BT) is the last step to obtain a nursing degree. In order to perform an effective assessment of a nursing BT, certain reliable and valid tools are required. To develop and validate a 3-rubric system (drafting process, dissertation, and viva) to assess final year nursing students' BT. A multi-disciplinary study of content validity and psychometric properties. The study was carried out between December 2014 and July 2015. Nursing Degree at Universitat Jaume I. Spain. Eleven experts (9 nursing professors and 2 education professors from 6 different universities) took part in the development and content validity stages. Fifty-two theses presented during the 2014-2015 academic year were included by consecutive sampling of cases in order to study the psychometric properties. First, a group of experts was created to validate the content of the assessment system based on three rubrics (drafting process, dissertation, and viva). Subsequently, a reliability and validity study of the rubrics was carried out on the 52 theses presented during the 2014-2015 academic year. The BT drafting process rubric has 8 criteria (S-CVI=0.93; α=0.837; ICC=0.614), the dissertation rubric has 7 criteria (S-CVI=0.9; α=0.893; ICC=0.74), and the viva rubric has 4 criteria (S-CVI=0.86; α=8.16; ICC=0.895). A nursing BT assessment system based on three rubrics (drafting process, dissertation, and viva) has been validated. This system may be transferred to other nursing degrees or degrees from other academic areas. It is necessary to continue with the validation process taking into account factors that may affect the results obtained. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Validity and Reliability of the Clinical Competency Evaluation Instrument for Use among Physiotherapy Students: Pilot study.

    Science.gov (United States)

    Muhamad, Zailani; Ramli, Ayiesah; Amat, Salleh

    2015-05-01

    The aim of this study was to determine the content validity, internal consistency, test-retest reliability and inter-rater reliability of the Clinical Competency Evaluation Instrument (CCEVI) in assessing the clinical performance of physiotherapy students. This study was carried out between June and September 2013 at University Kebangsaan Malaysia (UKM), Kuala Lumpur, Malaysia. A panel of 10 experts were identified to establish content validity by evaluating and rating each of the items used in the CCEVI with regards to their relevance in measuring students' clinical competency. A total of 50 UKM undergraduate physiotherapy students were assessed throughout their clinical placement to determine the construct validity of these items. The instrument's reliability was determined through a cross-sectional study involving a clinical performance assessment of 14 final-year undergraduate physiotherapy students. The content validity index of the entire CCEVI was 0.91, while the proportion of agreement on the content validity indices ranged from 0.83-1.00. The CCEVI construct validity was established with factor loading of ≥0.6, while internal consistency (Cronbach's alpha) overall was 0.97. Test-retest reliability of the CCEVI was confirmed with a Pearson's correlation range of 0.91-0.97 and an intraclass coefficient correlation range of 0.95-0.98. Inter-rater reliability of the CCEVI domains ranged from 0.59 to 0.97 on initial and subsequent assessments. This pilot study confirmed the content validity of the CCEVI. It showed high internal consistency, thereby providing evidence that the CCEVI has moderate to excellent inter-rater reliability. However, additional refinement in the wording of the CCEVI items, particularly in the domains of safety and documentation, is recommended to further improve the validity and reliability of the instrument.

  15. Measuring Students' Writing Ability on a Computer-Analytic Developmental Scale: An Exploratory Validity Study

    Science.gov (United States)

    Burdick, Hal; Swartz, Carl W.; Stenner, A. Jackson; Fitzgerald, Jill; Burdick, Don; Hanlon, Sean T.

    2013-01-01

    The purpose of the study was to explore the validity of a novel computer-analytic developmental scale, the Writing Ability Developmental Scale. On the whole, collective results supported the validity of the scale. It was sensitive to writing ability differences across grades and sensitive to within-grade variability as compared to human-rated…

  16. Electron-electron luminosity in the Next Linear Collider -- a preliminary study

    International Nuclear Information System (INIS)

    Zimmermann, F.; Thompson, K.A.; Helm, R.H.

    1997-11-01

    In this paper, the authors discuss some operational aspects of electron-electron collisions at the Next Linear Collider (NLC) and estimate the luminosity attainable in such a machine. They also consider the use of two future technologies which could simplify the operation and improve the luminosity in an e - e - collider: polarized rf guns and plasma lenses

  17. Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model.

    Science.gov (United States)

    Abid, Abubakar; O'Brien, Jonathan M; Bensel, Taylor; Cleveland, Cody; Booth, Lucas; Smith, Brian R; Langer, Robert; Traverso, Giovanni

    2017-04-27

    Electronic devices placed in the gastrointestinal (GI) tract for prolonged periods have the potential to transform clinical evaluation and treatment. One challenge to the deployment of such gastroresident electronics is the difficulty in powering millimeter-sized electronics devices without using batteries, which compromise biocompatibility and long-term residence. We examined the feasibility of leveraging mid-field wireless powering to transfer power from outside of the body to electronics at various locations along the GI tract. Using simulations and ex vivo measurements, we designed mid-field antennas capable of operating efficiently in tissue at 1.2 GHz. These antennas were then characterized in vivo in five anesthetized pigs, by placing one antenna outside the body, and the other antenna inside the body endoscopically, at the esophagus, stomach, and colon. Across the animals tested, mean transmission efficiencies of -41.2, -36.1, and -34.6 dB were achieved in vivo while coupling power from outside the body to the esophagus, stomach, and colon, respectively. This corresponds to power levels of 37.5 μW, 123 μW and 173 μW received by antennas in the respective locations, while keeping radiation exposure levels below safety thresholds. These power levels are sufficient to wirelessly power a range of medical devices from outside of the body.

  18. Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model

    Science.gov (United States)

    Abid, Abubakar; O'Brien, Jonathan M.; Bensel, Taylor; Cleveland, Cody; Booth, Lucas; Smith, Brian R.; Langer, Robert; Traverso, Giovanni

    2017-04-01

    Electronic devices placed in the gastrointestinal (GI) tract for prolonged periods have the potential to transform clinical evaluation and treatment. One challenge to the deployment of such gastroresident electronics is the difficulty in powering millimeter-sized electronics devices without using batteries, which compromise biocompatibility and long-term residence. We examined the feasibility of leveraging mid-field wireless powering to transfer power from outside of the body to electronics at various locations along the GI tract. Using simulations and ex vivo measurements, we designed mid-field antennas capable of operating efficiently in tissue at 1.2 GHz. These antennas were then characterized in vivo in five anesthetized pigs, by placing one antenna outside the body, and the other antenna inside the body endoscopically, at the esophagus, stomach, and colon. Across the animals tested, mean transmission efficiencies of -41.2, -36.1, and -34.6 dB were achieved in vivo while coupling power from outside the body to the esophagus, stomach, and colon, respectively. This corresponds to power levels of 37.5 μW, 123 μW and 173 μW received by antennas in the respective locations, while keeping radiation exposure levels below safety thresholds. These power levels are sufficient to wirelessly power a range of medical devices from outside of the body.

  19. Value-Eroding Teacher Behaviors Scale: A Validity and Reliability Study

    Science.gov (United States)

    Arseven, Zeynep; Kiliç, Abdurrahman; Sahin, Seyma

    2016-01-01

    In the present study, it is aimed to develop a valid and reliable scale for determining value-eroding behaviors of teachers, hence their values of judgment. The items of the "Value-eroding Teacher Behaviors Scale" were designed in the form of 5-point likert type rating scale. The exploratory factor analysis (EFA) was conducted to…

  20. Validation Study of the Abbreviated Math Anxiety Scale: Spanish Adaptation

    Science.gov (United States)

    Brown, Jennifer L.; Sifuentes, Lucía Macías

    2016-01-01

    With growing numbers of Hispanic students enrolling in post-secondary school, there is a need to increase retention and graduation rates. The purpose of this study was to validate the Spanish adaptation of the Abbreviated Math Anxiety Scale (AMAS). The AMAS was translated and administered to 804 freshman students at a post-secondary institution in…