WorldWideScience

Sample records for validation study electronic

  1. A magnetospheric specification model validation study: Geosynchronous electrons

    Science.gov (United States)

    Hilmer, R. V.; Ginet, G. P.

    2000-09-01

    The Rice University Magnetospheric Specification Model (MSM) is an operational space environment model of the inner and middle magnetosphere designed to specify charged particle fluxes up to 100keV. Validation test data taken between January 1996 and June 1998 consist of electron fluxes measured by a charge control system (CCS) on a defense satellite communications system (DSCS) spacecraft. The CCS includes both electrostatic analyzers to measure the particle environment and surface potential monitors to track differential charging between various materials and vehicle ground. While typical RMS error analysis methods provide a sense of the models overall abilities, they do not specifically address physical situations critical to operations, i.e., how well does the model specify when a high differential charging state is probable. In this validation study, differential charging states observed by DSCS are used to determine several threshold fluxes for the associated 20-50keV electrons and joint probability distributions are constructed to determine Hit, Miss, and False Alarm rates for the models. An MSM run covering the two and one-half year interval is performed using the minimum required input parameter set, consisting of only the magnetic activity index Kp, in order to statistically examine the model's seasonal and yearly performance. In addition, the relative merits of the input parameter, i.e., Kp, Dst, the equatorward boundary of diffuse aurora at midnight, cross-polar cap potential, solar wind density and velocity, and interplanetary magnetic field values, are evaluated as drivers of shorter model runs of 100 d each. In an effort to develop operational tools that can address spacecraft charging issues, we also identify temporal features in the model output that can be directly linked to input parameter variations and model boundary conditions. All model output is interpreted using the full three-dimensional, dipole tilt-dependent algorithms currently in

  2. Validation of fragility fractures in primary care electronic medical records: A population-based study.

    Science.gov (United States)

    Martinez-Laguna, Daniel; Soria-Castro, Alberto; Carbonell-Abella, Cristina; Orozco-López, Pilar; Estrada-Laza, Pilar; Nogues, Xavier; Díez-Perez, Adolfo; Prieto-Alhambra, Daniel

    2017-11-28

    Electronic medical records databases use pre-specified lists of diagnostic codes to identify fractures. These codes, however, are not specific enough to disentangle traumatic from fragility-related fractures. We report on the proportion of fragility fractures identified in a random sample of coded fractures in SIDIAP. Patients≥50 years old with any fracture recorded in 2012 (as per pre-specified ICD-10 codes) and alive at the time of recruitment were eligible for this retrospective observational study in 6 primary care centres contributing to the SIDIAP database (www.sidiap.org). Those with previous fracture/s, non-responders, and those with dementia or a serious psychiatric disease were excluded. Data on fracture type (traumatic vs fragility), skeletal site, and basic patient characteristics were collected. Of 491/616 (79.7%) patients with a registered fracture in 2012 who were contacted, 331 (349 fractures) were included. The most common fractures were forearm (82), ribs (38), and humerus (32), and 225/349 (64.5%) were fragility fractures, with higher proportions for classic osteoporotic sites: hip, 91.7%; spine, 87.7%; and major fractures, 80.5%. This proportion was higher in women, the elderly, and patients with a previously coded diagnosis of osteoporosis. More than 4 in 5 major fractures recorded in SIDIAP are due to fragility (non-traumatic), with higher proportions for hip (92%) and vertebral (88%) fracture, and a lower proportion for fractures other than major ones. Our data support the validity of SIDIAP for the study of the epidemiology of osteoporotic fractures. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  3. Dual-Material Electron Beam Selective Melting: Hardware Development and Validation Studies

    Directory of Open Access Journals (Sweden)

    Chao Guo

    2015-03-01

    Full Text Available Electron beam selective melting (EBSM is an additive manufacturing technique that directly fabricates three-dimensional parts in a layerwise fashion by using an electron beam to scan and melt metal powder. In recent years, EBSM has been successfully used in the additive manufacturing of a variety of materials. Previous research focused on the EBSM process of a single material. In this study, a novel EBSM process capable of building a gradient structure with dual metal materials was developed, and a powder-supplying method based on vibration was put forward. Two different powders can be supplied individually and then mixed. Two materials were used in this study: Ti6Al4V powder and Ti47Al2Cr2Nb powder. Ti6Al4V has excellent strength and plasticity at room temperature, while Ti47Al2Cr2Nb has excellent performance at high temperature, but is very brittle. A Ti6Al4V/Ti47Al2Cr2Nb gradient material was successfully fabricated by the developed system. The microstructures and chemical compositions were characterized by optical microscopy, scanning microscopy, and electron microprobe analysis. Results showed that the interface thickness was about 300 μm. The interface was free of cracks, and the chemical compositions exhibited a staircase-like change within the interface.

  4. Validation of cell-free culture using scanning electron microscopy (SEM) and gene expression studies.

    Science.gov (United States)

    Yang, R; Elankumaran, Y; Hijjawi, N; Ryan, U

    2015-06-01

    A cell-free culture system for Cryptosporidium parvum was analysed using scanning electron microscopy (SEM) to characterise life cycle stages and compare gene expression in cell-free culture and cell culture using HCT-8 cells. Cryptosporidium parvum samples were harvested at 2 h, 8 h, 14 h, 26 h, 50 h, 74 h, 98 h, 122 h and 170 h, chemically fixed and specimens were observed using a Zeiss 1555 scanning electron microscope. The presence of sporozoites, trophozoites and type I merozoites were identified by SEM. Gene expression in cell culture and cell-free culture was studied using reverse transcriptase quantitative PCR (RT-qPCR) of the sporozoite surface antigen protein (cp15), the glycoprotein 900 (gp900), the Cryptosporidium oocyst wall protein (COWP) and 18S ribosomal RNA (rRNA) genes in both cell free and conventional cell culture. In cell culture, cp15 expression peaked at 74 h, gp900 expression peaked at 74 h and 98 h and COWP expression peaked at 50 h. In cell-free culture, CP15 expression peaked at 98 h, gp900 expression peaked at 74 h and COWP expression peaked at 122 h. The present study is the first to compare gene expression of C. parvum in cell culture and cell-free culture and to characterise life cycle stages of C. parvum in cell-free culture using SEM. Findings from this study showed that gene expression patterns in cell culture and cell-free culture were similar but in cell-free culture, gene expression was delayed for CP15 and COWP in cell free culture compared with the cell culture system and was lower. Although three life cycle stageswere conclusively identified, improvements in SEM methodology should lead to the detection of more life cycle stages. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. The validity of Cloze Oriented System (COS: a correlation study with an electronic comprehension test and a reading attitude survey

    Directory of Open Access Journals (Sweden)

    Maria Cristina Rodrigues Azevedo Joly

    Full Text Available This study aimed to analyze the efficiency of the Cloze Oriented System (COS considering its relation with reading attitude and its validity. The Electronic Program Comprehension (EPC for students from K1 to K4 based on the COS parts of stories from the Brazilian Children's literature was applied in eighteen class-hours. The 40 subjects, ten in each grade, of both genders aged 7 to 11 years, were evaluated before and after the EPC with a Cloze test. They answered the Elementary Reading Attitude Survey too, in a printed protocol adapted to Portuguese, to evaluate the reading attitude of the students and the influence of the EPC in the academic and recreational reading. The results showed that the performance in reading comprehension of all the subjects was higher after taking part in the EPC, and also had significant differences in reading attitude, according to the results of the T of Wilcoxon statistic test. A correlation between comprehension performance before and after the EPC and the reading attitude was verified. There was significant difference for academic reading attitude in the post-test between proficient readers and the one's that has low skill.

  6. Electronic unit for fotovoltaic solar panelling validation

    International Nuclear Information System (INIS)

    Vazquez, J.; Valverde, J.; Garcia, J.M.

    1988-01-01

    A low cost and easy to use electronic system for photovoltaic solar panelling validation is described. It measures, with a certain periodicity, voltage and current given by the panel, determines the supplied power, and every so often, its maximum valves. The unit is fitted with a data storage system which allows data recording for later analysis. (Author)

  7. study of the effects of ionization on medicinal plants and validation of an analysis method adapted by electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Ben Khedim, Meriem

    2011-01-01

    The results of EPR and UV-Vis Spectroscopy studies on dry medicinal herbs of fenugreek, fennel, pollen and marjoram; before and after Gamma irradiation by Cobalt 60 source at doses from 3 to 50 kGy are reported and expressed as DPPH radical scavenging ability of each Herb's extract and as EPR intensity signal of each Herb's powder. Before irradiation, all samples exhibit one weak singlet EPR line with a g-factor at 2.004 2 .005 attributed to a quinone radical. Irradiation induced a significant increase in signal intensity relative to the free radicals without any change in spectral pattern. This increase is proportional to the absorbed dose and to the content of free radicals. Up to the optimal dose (19kGy); decay is shown with exceptions for 30, 35 or 40 kGy according the studied herb. The stability of the obtained EPR signal of irradiated samples was studied over a storage period of 90 days after radiation process and the results showed a significant decrease of free radicals signal intensity until their stability. All the EPR measurements were performed after the analytical method by EPR spectroscopy's validation.

  8. Study, development and validation of a dead-timeless electronic architecture concept for highly sensitive PET (Positron Emission Tomograph)

    International Nuclear Information System (INIS)

    Vert, P.E.

    2007-03-01

    Positron emission tomographs (PET) are fitted with highly capable reading electronics, which owns qualities and drawbacks. Highly accused at first as an explanation of the poor sensitivity of these imagers, the present study points out that the dead-times shared along the chains contribute to only 16 % in the data losses at a typical activity of 10 μCi/ml. The gross acquisition rates could thus be raised by 20 % through a suppression of these saturations. Looking in details at the philosophy of the acquisition procedure, a property appears to circumscribe the sensitivity even more: the timing resolution. The latter conditions, to the first order, the rejection capabilities of random events, part of the scattered ones and hence noise which is finally rated to the true coincidences the signal is made up of. Minimizing the resolving time goes through the suppression of the unneeded actors along with the adoption of a well adapted time-stamping method (optimal filtering). In doing so, the intrinsic channel resolution appears to be possibly lowered by a factor 7, reducing to 350 ps. The bottom value of the coincidence window may be narrowed as a consequence, leading to an increase of the NECR (noise equivalent count rate) by 50 per cent. At this stage, a time of flight (TOF) algorithms can be implemented. As an opportunist, it promises a reduction of the noise variance by 430 %, a gain that echoes on the NECR figure. Finally merging all these ideas allows to expect an improvement close to an order of magnitude on the NECR, with the hope of routine exams shortened by the same amount. In this context, it appeared logical to imagine a new electronics acquisition synoptic dedicated to fully pixelized PET. The number of channels blows up by the way when compared to the existing, this statement being partially balanced by the decision to fully integrate the electronics. The measures of the energy and time are planned to be performed with a single channel, with a continuous

  9. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    OpenAIRE

    Daniel D. Reidpath; Mei Lee Ling; Shajahan Yasin; Kanason Rajagobal; Pascale Allotey

    2012-01-01

    Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers usin...

  10. From patient care to research: a validation study examining the factors contributing to data quality in a primary care electronic medical record database.

    Science.gov (United States)

    Coleman, Nathan; Halas, Gayle; Peeler, William; Casaclang, Natalie; Williamson, Tyler; Katz, Alan

    2015-02-05

    Electronic Medical Records (EMRs) are increasingly used in the provision of primary care and have been compiled into databases which can be utilized for surveillance, research and informing practice. The primary purpose of these records is for the provision of individual patient care; validation and examination of underlying limitations is crucial for use for research and data quality improvement. This study examines and describes the validity of chronic disease case definition algorithms and factors affecting data quality in a primary care EMR database. A retrospective chart audit of an age stratified random sample was used to validate and examine diagnostic algorithms applied to EMR data from the Manitoba Primary Care Research Network (MaPCReN), part of the Canadian Primary Care Sentinel Surveillance Network (CPCSSN). The presence of diabetes, hypertension, depression, osteoarthritis and chronic obstructive pulmonary disease (COPD) was determined by review of the medical record and compared to algorithm identified cases to identify discrepancies and describe the underlying contributing factors. The algorithm for diabetes had high sensitivity, specificity and positive predictive value (PPV) with all scores being over 90%. Specificities of the algorithms were greater than 90% for all conditions except for hypertension at 79.2%. The largest deficits in algorithm performance included poor PPV for COPD at 36.7% and limited sensitivity for COPD, depression and osteoarthritis at 72.0%, 73.3% and 63.2% respectively. Main sources of discrepancy included missing coding, alternative coding, inappropriate diagnosis detection based on medications used for alternate indications, inappropriate exclusion due to comorbidity and loss of data. Comparison to medical chart review shows that at MaPCReN the CPCSSN case finding algorithms are valid with a few limitations. This study provides the basis for the validated data to be utilized for research and informs users of its

  11. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  12. Online Prediction of Health Care Utilization in the Next Six Months Based on Electronic Health Record Information: A Cohort and Validation Study.

    Science.gov (United States)

    Hu, Zhongkai; Hao, Shiying; Jin, Bo; Shin, Andrew Young; Zhu, Chunqing; Huang, Min; Wang, Yue; Zheng, Le; Dai, Dorothy; Culver, Devore S; Alfreds, Shaun T; Rogow, Todd; Stearns, Frank; Sylvester, Karl G; Widen, Eric; Ling, Xuefeng

    2015-09-22

    The increasing rate of health care expenditures in the United States has placed a significant burden on the nation's economy. Predicting future health care utilization of patients can provide useful information to better understand and manage overall health care deliveries and clinical resource allocation. This study developed an electronic medical record (EMR)-based online risk model predictive of resource utilization for patients in Maine in the next 6 months across all payers, all diseases, and all demographic groups. In the HealthInfoNet, Maine's health information exchange (HIE), a retrospective cohort of 1,273,114 patients was constructed with the preceding 12-month EMR. Each patient's next 6-month (between January 1, 2013 and June 30, 2013) health care resource utilization was retrospectively scored ranging from 0 to 100 and a decision tree-based predictive model was developed. Our model was later integrated in the Maine HIE population exploration system to allow a prospective validation analysis of 1,358,153 patients by forecasting their next 6-month risk of resource utilization between July 1, 2013 and December 31, 2013. Prospectively predicted risks, on either an individual level or a population (per 1000 patients) level, were consistent with the next 6-month resource utilization distributions and the clinical patterns at the population level. Results demonstrated the strong correlation between its care resource utilization and our risk scores, supporting the effectiveness of our model. With the online population risk monitoring enterprise dashboards, the effectiveness of the predictive algorithm has been validated by clinicians and caregivers in the State of Maine. The model and associated online applications were designed for tracking the evolving nature of total population risk, in a longitudinal manner, for health care resource utilization. It will enable more effective care management strategies driving improved patient outcomes.

  13. Challenges in validating radiation sterilization with low energy electron irradiation

    International Nuclear Information System (INIS)

    Miller, A.; Helt-Hansen, J.

    2011-01-01

    Complete text of publication follows. Low energy electron irradiation (80-300 keV) is used increasingly for sterilization or decontamination in connection with isolators for aseptic filling lines in the pharmaceutical industry. It is not defined how validation for this process shall be carried out. A method can be derived from the medical device standard for radiation sterilization, ISO 11137, because the principles described in this standard can be applied to almost any industrial irradiation process. The validations elements are: Process definition, concerning specification of the dose required for the process and the maximum acceptable dose for the product. Installation qualification, concerning acceptance the irradiation facility. Operational qualification, concerning characterization of the facility. Performance qualification, concerning setting up the process. Process control, concerning routine monitoring. The limited penetration of the low energy electrons leads to problems with respect to executing these validation steps. This paper discusses these problems, and shows with examples how they can be solved.

  14. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1990-01-01

    Our laboratory has made significant progress this year in devising improved electron-optical systems, in studying invertebrate hemoglobins with the STEM, and in achieving a workable sub-angstrom STEM. Our goal in electron optics is to improve resolution by producing spherical and chromatic aberration coefficients with signs opposite those of magnetic lenses. We have progressed toward this goal through calculations that explore the addition of electrodes to electron mirrors to reduce these two geometric aberrations and by devising a beam separation system that won't introduce asymmetrical aberrations. Some promising new designs of magnetic lenses for SEM applications have also been investigated. We have continued our exploration of the quaternary structure of the invertebrate hemoglobins and are now among the top laboratories in this area of expertise. In addition, we have overcome many of our electronic difficulties on the sub-angstrom STEM and have made significant progress toward achieving an operational system. The addition of an IBM RISC-6000 workstation to our lab has significantly increased our image processing capabilities

  15. Validation of an electronic surveillance system for acute lung injury.

    Science.gov (United States)

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D; Gajic, Ognjen

    2009-06-01

    Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Using a near-real time copy of the electronic medical records, we developed and validated a custom ALI electronic alert (ALI "sniffer") based on the European-American Consensus Conference Definition and compared its performance against provider-derived documentation. A total of 3,795 consecutive critically ill patients admitted to nine multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution were included. ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs. 8.0 ml/kg predicted body weight, P sniffer" demonstrated excellent sensitivity of 96% (95% CI 94-98) and moderate specificity of 89% (95% CI 88-90) with a positive predictive value ranging from 24% (95% CI 13-40) in the heart-lung transplant ICU to 64% (95% CI 55-71) in the medical ICU. The computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research.

  16. Basic Conditions of Validity of Electronic Contracts in Iran and UNCITRAL Model Law

    Directory of Open Access Journals (Sweden)

    Abbas Karimi

    2017-02-01

    Full Text Available Diverse activities such as electronic exchange of goods and services, instant digital content delivery, electronic funds transfer, electronic stock exchange, electronic bill of lading, commercial projects, common engineering and design, sourcing, government purchase, direct marketing and post-sales services included in e-commerce field.  Due to the increasing spread of the electronic world in all aspects, electronic contracts, in turn, was of great importance and made significant contributions in business contracts. The present study aims to investigate the concept, fundamentals and history of electronic contracts referring to UNCITRAL Model Law on Electronic Commerce and Electronic Commerce Act (1996. The results indicate that in terms of the conclusion and obligations of the parties, contract in cyberspace in general is similar to the contract in the real world and in this respect, there is no major difference between these two contexts. Potential electronic contracts considered as written ones and Electronic signatures recognized as valid as the basis of the validity of the will in electronic trading.

  17. Validation of asthma recording in electronic health records: a systematic review

    Directory of Open Access Journals (Sweden)

    Nissen F

    2017-12-01

    Full Text Available Francis Nissen,1 Jennifer K Quint,2 Samantha Wilkinson,1 Hana Mullerova,3 Liam Smeeth,1 Ian J Douglas1 1Department of Non-Communicable Disease Epidemiology, London School of Hygiene and Tropical Medicine, London, UK; 2National Heart and Lung Institute, Imperial College, London, UK; 3RWD & Epidemiology, GSK R&D, Uxbridge, UK Objective: To describe the methods used to validate asthma diagnoses in electronic health records and summarize the results of the validation studies. Background: Electronic health records are increasingly being used for research on asthma to inform health services and health policy. Validation of the recording of asthma diagnoses in electronic health records is essential to use these databases for credible epidemiological asthma research.Methods: We searched EMBASE and MEDLINE databases for studies that validated asthma diagnoses detected in electronic health records up to October 2016. Two reviewers independently assessed the full text against the predetermined inclusion criteria. Key data including author, year, data source, case definitions, reference standard, and validation statistics (including sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV] were summarized in two tables.Results: Thirteen studies met the inclusion criteria. Most studies demonstrated a high validity using at least one case definition (PPV >80%. Ten studies used a manual validation as the reference standard; each had at least one case definition with a PPV of at least 63%, up to 100%. We also found two studies using a second independent database to validate asthma diagnoses. The PPVs of the best performing case definitions ranged from 46% to 58%. We found one study which used a questionnaire as the reference standard to validate a database case definition; the PPV of the case definition algorithm in this study was 89%. Conclusion: Attaining high PPVs (>80% is possible using each of the discussed validation

  18. Validation Test of Geant4 Simulation of Electron Backscattering

    CERN Document Server

    Kim, Sung Hun; Basaglia, Tullio; Han, Min Cheol; Hoff, Gabriela; Kim, Chan Hyeong; Saracco, Paolo

    2015-01-01

    Backscattering is a sensitive probe of the accuracy of electron scattering algorithms implemented in Monte Carlo codes. The capability of the Geant4 toolkit to describe realistically the fraction of electrons backscattered from a target volume is extensively and quantitatively evaluated in comparison with experimental data retrieved from the literature. The validation test covers the energy range between approximately 100 eV and 20 MeV, and concerns a wide set of target elements. Multiple and single electron scattering models implemented in Geant4, as well as preassembled selections of physics models distributed within Geant4, are analyzed with statistical methods. The evaluations concern Geant4 versions from 9.1 to 10.1. Significant evolutions are observed over the range of Geant4 versions, not always in the direction of better compatibility with experiment. Goodness-of-fit tests complemented by categorical analysis tests identify a configuration based on Geant4 Urban multiple scattering model in Geant4 vers...

  19. CTF Void Drift Validation Study

    Energy Technology Data Exchange (ETDEWEB)

    Salko, Robert K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gosdin, Chris [Pennsylvania State Univ., University Park, PA (United States); Avramova, Maria N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gergar, Marcus [Pennsylvania State Univ., University Park, PA (United States)

    2015-10-26

    This milestone report is a summary of work performed in support of expansion of the validation and verification (V&V) matrix for the thermal-hydraulic subchannel code, CTF. The focus of this study is on validating the void drift modeling capabilities of CTF and verifying the supporting models that impact the void drift phenomenon. CTF uses a simple turbulent-diffusion approximation to model lateral cross-flow due to turbulent mixing and void drift. The void drift component of the model is based on the Lahey and Moody model. The models are a function of two-phase mass, momentum, and energy distribution in the system; therefore, it is necessary to correctly model the ow distribution in rod bundle geometry as a first step to correctly calculating the void distribution due to void drift.

  20. Electronics Industry Study Report

    National Research Council Canada - National Science Library

    Belt, David; Fellows, John R; Kameru, Philip; Nazaroff, Boris-Frank A; Pauroso, Anthony; Schulz, Frederick; Ballew, Bob; Bond, Thomas; Demers, Stephy; Kirkpatrick, Steve

    2005-01-01

    This paper provides a national strategy for the US electronics industry. Electronics is one of the largest industries in the US and plays a critical role in almost every aspect of national security...

  1. Validation of asthma recording in electronic health records: protocol for a systematic review.

    Science.gov (United States)

    Nissen, Francis; Quint, Jennifer K; Wilkinson, Samantha; Mullerova, Hana; Smeeth, Liam; Douglas, Ian J

    2017-05-29

    Asthma is a common, heterogeneous disease with significant morbidity and mortality worldwide. It can be difficult to define in epidemiological studies using electronic health records as the diagnosis is based on non-specific respiratory symptoms and spirometry, neither of which are routinely registered. Electronic health records can nonetheless be valuable to study the epidemiology, management, healthcare use and control of asthma. For health databases to be useful sources of information, asthma diagnoses should ideally be validated. The primary objectives are to provide an overview of the methods used to validate asthma diagnoses in electronic health records and summarise the results of the validation studies. EMBASE and MEDLINE will be systematically searched for appropriate search terms. The searches will cover all studies in these databases up to October 2016 with no start date and will yield studies that have validated algorithms or codes for the diagnosis of asthma in electronic health records. At least one test validation measure (sensitivity, specificity, positive predictive value, negative predictive value or other) is necessary for inclusion. In addition, we require the validated algorithms to be compared with an external golden standard, such as a manual review, a questionnaire or an independent second database. We will summarise key data including author, year of publication, country, time period, date, data source, population, case characteristics, clinical events, algorithms, gold standard and validation statistics in a uniform table. This study is a synthesis of previously published studies and, therefore, no ethical approval is required. The results will be submitted to a peer-reviewed journal for publication. Results from this systematic review can be used to study outcome research on asthma and can be used to identify case definitions for asthma. CRD42016041798. © Article author(s) (or their employer(s) unless otherwise stated in the text of the

  2. Development and validation of electronic surveillance tool for acute kidney injury: A retrospective analysis.

    Science.gov (United States)

    Ahmed, Adil; Vairavan, Srinivasan; Akhoundi, Abbasali; Wilson, Gregory; Chiofolo, Caitlyn; Chbat, Nicolas; Cartin-Ceba, Rodrigo; Li, Guangxi; Kashani, Kianoush

    2015-10-01

    Timely detection of acute kidney injury (AKI) facilitates prevention of its progress and potentially therapeutic interventions. The study objective is to develop and validate an electronic surveillance tool (AKI sniffer) to detect AKI in 2 independent retrospective cohorts of intensive care unit (ICU) patients. The primary aim is to compare the sensitivity, specificity, and positive and negative predictive values of AKI sniffer performance against a reference standard. This study is conducted in the ICUs of a tertiary care center. The derivation cohort study subjects were Olmsted County, MN, residents admitted to all Mayo Clinic ICUs from July 1, 2010, through December 31, 2010, and the validation cohort study subjects were all patients admitted to a Mayo Clinic, Rochester, campus medical/surgical ICU on January 12, 2010, through March 23, 2010. All included records were reviewed by 2 independent investigators who adjudicated AKI using the Acute Kidney Injury Network criteria; disagreements were resolved by a third reviewer. This constituted the reference standard. An electronic algorithm was developed; its precision and reliability were assessed in comparison with the reference standard in 2 separate cohorts, derivation and validation. Of 1466 screened patients, a total of 944 patients were included in the study: 482 for derivation and 462 for validation. Compared with the reference standard in the validation cohort, the sensitivity and specificity of the AKI sniffer were 88% and 96%, respectively. The Cohen κ (95% confidence interval) agreement between the electronic and the reference standard was 0.84 (0.78-0.89) and 0.85 (0.80-0.90) in the derivation and validation cohorts. Acute kidney injury can reliably and accurately be detected electronically in ICU patients. The presented method is applicable for both clinical (decision support) and research (enrollment for clinical trials) settings. Prospective validation is required. Copyright © 2015 Elsevier Inc. All

  3. Using linked electronic data to validate algorithms for health outcomes in administrative databases.

    Science.gov (United States)

    Lee, Wan-Ju; Lee, Todd A; Pickard, Alan Simon; Shoaibi, Azadeh; Schumock, Glen T

    2015-08-01

    The validity of algorithms used to identify health outcomes in claims-based and administrative data is critical to the reliability of findings from observational studies. The traditional approach to algorithm validation, using medical charts, is expensive and time-consuming. An alternative method is to link the claims data to an external, electronic data source that contains information allowing confirmation of the event of interest. In this paper, we describe this external linkage validation method and delineate important considerations to assess the feasibility and appropriateness of validating health outcomes using this approach. This framework can help investigators decide whether to pursue an external linkage validation method for identifying health outcomes in administrative/claims data.

  4. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1991-01-01

    This year our laboratory has continued to make progress in the design of electron-optical systems, in the study of structure-function relationships of large multi-subunit proteins, in the development of new image processing software and in achieving a workable sub-angstrom STEM. We present an algebraic approach to the symmetrical Einzel (unipotential) lens wherein we simplify the analysis by specifying a field shape that meets some preferred set of boundary or other conditions and then calculate the fields. In a second study we generalize this approach to study of three element electrostatic lenses of which the symmetrical Einzel lens is a particular form. The purpose is to develop a method for assisting in the design of a lens for a particular purpose. In our biological work we study a stable and functional dodecameric complex of globin chains from the hemoglobin of Lumbricus terrestris. This is a complex lacking the ''linker'' subunit first imaged in this lab and required for maintenance of the native structure. In addition, we do a complete work-up on the hemoglobin of the marine polychaete Eudistylia vancouverii demonstrating the presence of a hierarchy of globin complexes. We demonstrate stable field-emission in the sub-angstrom STEM and the preliminary alignment of the beam. We continue our exploration of a algorithms for alignment of sequences of protein and DNA. Our computer facilities now include four second generation RISC workstations and we continue to take increasing advantage of the floating-point and graphical performance of these devices

  5. Social Studies by Electronic Mail.

    Science.gov (United States)

    Barr, Hugh

    1994-01-01

    Asserts that electronic mail provides opportunities to engage students actively in cross-cultural contact with students in other nations. Discusses advantages and problems with using electronic mail in the social studies classroom. Describes electronic mail projects that link students in New Zealand, England, and the United States. (CFR)

  6. Experimental validation of a radio frequency photogun as external electron

    NARCIS (Netherlands)

    Stragier, X.F.D.; Luiten, O.J.; Geer, van der S.B.; Wiel, van der M.J.

    2011-01-01

    A purpose-built RF-photogun as external electron injector for a laser wakefield accelerator has been thoroughly tested. Different properties of the RF-photogun have been measured such as energy, energy spread and transverse emittance. The focus of this study is the investigation of the smallest

  7. Molecular studies by electron spectroscopy

    International Nuclear Information System (INIS)

    Hansteen, J.M.

    1977-01-01

    Experience gained in experimental nuclear physics has played a large role in the development of electron spectroscopy as a powerful tool for studying chemical systems. The use of ESCA (Electron Spectroscopy for Chemical Analysis) for the mapping of molecular properties connected with inner as well as outer electron shells is reviewed, mainly from a phenomological point of view. Molecular Auger electron spectroscopy is described as a means of gaining information on details in molecular structure, simultaneously being extensively applied for surface studies. Future highly promising research areas for molecular electron spectroscopy are suggested to be (e,2e) processes as well as continued exploitation of synchrotron radiation from high energy nuclear devices. (Auth.)

  8. Development and validation of a Hospital Frailty Risk Score focusing on older people in acute care settings using electronic hospital records: an observational study.

    Science.gov (United States)

    Gilbert, Thomas; Neuburger, Jenny; Kraindler, Joshua; Keeble, Eilis; Smith, Paul; Ariti, Cono; Arora, Sandeepa; Street, Andrew; Parker, Stuart; Roberts, Helen C; Bardsley, Martin; Conroy, Simon

    2018-05-05

    Older people are increasing users of health care globally. We aimed to establish whether older people with characteristics of frailty and who are at risk of adverse health-care outcomes could be identified using routinely collected data. A three-step approach was used to develop and validate a Hospital Frailty Risk Score from International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) diagnostic codes. First, we carried out a cluster analysis to identify a group of older people (≥75 years) admitted to hospital who had high resource use and diagnoses associated with frailty. Second, we created a Hospital Frailty Risk Score based on ICD-10 codes that characterised this group. Third, in separate cohorts, we tested how well the score predicted adverse outcomes and whether it identified similar groups as other frailty tools. In the development cohort (n=22 139), older people with frailty diagnoses formed a distinct group and had higher non-elective hospital use (33·6 bed-days over 2 years compared with 23·0 bed-days for the group with the next highest number of bed-days). In the national validation cohort (n=1 013 590), compared with the 429 762 (42·4%) patients with the lowest risk scores, the 202 718 (20·0%) patients with the highest Hospital Frailty Risk Scores had increased odds of 30-day mortality (odds ratio 1·71, 95% CI 1·68-1·75), long hospital stay (6·03, 5·92-6·10), and 30-day readmission (1·48, 1·46-1·50). The c statistics (ie, model discrimination) between individuals for these three outcomes were 0·60, 0·68, and 0·56, respectively. The Hospital Frailty Risk Score showed fair overlap with dichotomised Fried and Rockwood scales (kappa scores 0·22, 95% CI 0·15-0·30 and 0·30, 0·22-0·38, respectively) and moderate agreement with the Rockwood Frailty Index (Pearson's correlation coefficient 0·41, 95% CI 0·38-0·47). The Hospital Frailty Risk Score provides hospitals and health

  9. 2001 Industry Studies: Electronics

    Science.gov (United States)

    2001-01-01

    Center, Dallas, TX Northrop Grumman Corp, Electronic Sensors & Systems, Baltimore, MD International Acer Incorporated, Hsin Chu, Taiwan Aerospace...manufacturing. Many of the large-scale fabrication foundries are offshore in such countries as Taiwan, Singapore and Malaysia .5 - 5 - The largest market for...done in the US. However, more of the actual mass manufacturing of the chips are done in Taiwan, Singapore, and Malaysia . A new semiconductor facility

  10. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1992-01-01

    This is a report covering the research performed in the Crewe laboratory between 1964 and 1992. Because of limitations of space we have provided relatively brief summaries of the major research directions of the facility during these years. A complete bibliography has been included and we have referenced groups of pertinent publications at the beginning of each section. This report summarizes our efforts to develop better electron microscopes and chronicles many of the experimental programs, in materials science and biology, that acted both as a stimulus to better microscope design and also as a testing ground for many instrumental innovations

  11. Electron microscope studies

    Energy Technology Data Exchange (ETDEWEB)

    Crewe, A.V.; Kapp, O.H.

    1992-07-01

    This is a report covering the research performed in the Crewe laboratory between 1964 and 1992. Because of limitations of space we have provided relatively brief summaries of the major research directions of the facility during these years. A complete bibliography has been included and we have referenced groups of pertinent publications at the beginning of each section. This report summarizes our efforts to develop better electron microscopes and chronicles many of the experimental programs, in materials science and biology, that acted both as a stimulus to better microscope design and also as a testing ground for many instrumental innovations.

  12. NVN 5694 intra laboratory validation. Feasibility study for interlaboratory- validation

    International Nuclear Information System (INIS)

    Voors, P.I.; Baard, J.H.

    1998-11-01

    Within the project NORMSTAR 2 a number of Dutch prenormative protocols have been defined for radioactivity measurements. Some of these protocols, e.g. the Dutch prenormative protocol NVN 5694, titled Methods for radiochemical determination of polonium-210 and lead-210, have not been validated, neither by intralaboratory nor interlaboratory studies. Validation studies are conducted within the framework of the programme 'Normalisatie and Validatie van Milieumethoden 1993-1997' (Standardization and Validation of test methods for environmental parameters) of the Dutch Ministry of Housing, Physical Planning and the Environment (VROM). The aims of this study were (a) a critical evaluation of the protocol, (b) investigation on the feasibility of an interlaboratory study, and (c) the interlaboratory validation of NVN 5694. The evaluation of the protocol resulted in a list of deficiencies varying from missing references to incorrect formulae. From the survey by interview it appeared that for each type of material, there are 4 to 7 laboratories willing to participate in a interlaboratory validation study. This reflects the situation in 1997. Consequently, if 4 or 6 (the minimal number) laboratories are participating and each laboratory analyses 3 subsamples, the uncertainty in the repeatability standard deviation is 49 or 40 %, respectively. If the ratio of reproducibility standard deviation to the repeatability standard deviation is equal to 1 or 2, then the uncertainty in the reproducibility standard deviation increases from 42 to 67 % and from 34 to 52 % for 4 or 6 laboratories, respectively. The intralaboratory validation was established on four different types of materials. Three types of materials (milkpowder condensate and filter) were prepared in the laboratory using the raw material and certified Pb-210 solutions, and one (sediment) was obtained from the IAEA. The ECN-prepared reference materials were used after testing on homogeneity. The pre-normative protocol can

  13. Cable SGEMP Code Validation Study

    Energy Technology Data Exchange (ETDEWEB)

    Ballard, William Parker [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Center for CA Weapons Systems Engineering

    2013-05-01

    This report compared data taken on the Modular Bremsstrahlung Simulator using copper jacketed (cujac) cables with calculations using the RHSD-RA Cable SGEMP analysis tool. The tool relies on CEPXS/ONBFP to perform radiation transport in a series of 1D slices through the cable, and then uses a Green function technique to evaluate the expected current drive on the center conductor. The data were obtained in 2003 as part of a Cabana verification and validation experiment using 1-D geometries, but were not evaluated until now. The agreement between data and model is not adequate unless gaps between the dielectric and outer conductor (ground) are assumed, and these gaps are large compared with what is believed to be in the actual cable.

  14. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  15. Study of the violation of the T and CP symmetries in the reactions Λb0 → Λ0 + a vector meson. Validation of the Front-end electronics for the PreShower detector of the LHCb experiment

    International Nuclear Information System (INIS)

    Conte, E.

    2007-11-01

    This thesis probes the beauty baryon physics in the framework of the LHCb experiment. The present study deals with the Λ b 0 → Λ 0 V decays where V is a vector meson such as J/Ψ(μ + μ - ), φ(K + K - ), ω(π + π - π0) or the ρ 0 - ω 0 (π + π - ) mixing. These processes allow to test independently the CP symmetry, which violation has not been observed yet in the baryonic sector, and the T symmetry, which experimental proofs are limited. Among the possible perspectives, a precise measurement of the Λ b 0 lifetime could contribute to the resolution of the raising theoretical-experimental puzzle. A phenomenological model of the Λ b 0 → Λ 0 V decays has been performed, from which branching ratios and angular distributions have been estimated. An advanced study of the reconstruction and the selection of these reactions by the LHCb apparatus shows that the channel Λ b 0 → Λ 0 J/Ψ is the dominant channel on both statistics and purity aspects. The Λ b 0 lifetime measure is the most imminent result; the constrains on asymmetries due to CP and T violation require several data taking years. Besides, an instrumental work has been achieved on the read-out electronics, called Front-End, of the experiment pre-shower. This contribution takes into account the validation of the prototype boards and the development of tools required by the qualification of the 100 production boards. (author)

  16. Validation studies of nursing diagnoses in neonatology

    Directory of Open Access Journals (Sweden)

    Pavlína Rabasová

    2016-03-01

    Full Text Available Aim: The objective of the review was the analysis of Czech and foreign literature sources and professional periodicals to obtain a relevant comprehensive overview of validation studies of nursing diagnoses in neonatology. Design: Review. Methods: The selection criterion was studies concerning the validation of nursing diagnoses in neonatology. To obtain data from relevant sources, the licensed professional databases EBSCO, Web of Science and Scopus were utilized. The search criteria were: date of publication - unlimited; academic periodicals - full text; peer-reviewed periodicals; search language - English, Czech and Slovak. Results: A total of 788 studies were found. Only 5 studies were eligible for content analysis, dealing specifically with validation of nursing diagnoses in neonatology. The analysis of the retrieved studies suggests that authors are most often concerned with identifying the defining characteristics of nursing diagnoses applicable to both the mother (parents and the newborn. The diagnoses were validated in the domains Role Relationship; Coping/Stress tolerance; Activity/Rest, and Elimination and Exchange. Diagnoses represented were from the field of dysfunctional physical needs as well as the field of psychosocial and spiritual needs. The diagnoses were as follows: Parental role conflict (00064; Impaired parenting (00056; Grieving (00136; Ineffective breathing pattern (00032; Impaired gas exchange (00030; and Impaired spontaneous ventilation (00033. Conclusion: Validation studies enable effective planning of interventions with measurable results and support clinical nursing practice.

  17. Materials of the Regional Training Course on Validation and Process Control for Electron Beam Radiation Processing

    International Nuclear Information System (INIS)

    Kaluska, I.; Gluszewski, W.

    2007-01-01

    Irradiation with electron beams is used in the polymer industry, food, pharmaceutical and medical device industries for sterilization of surfaces. About 20 lectures presented during the Course were devoted to all aspects of control and validation of low energy electron beam processes. They should help the product manufacturers better understand the application of the ANSI/AAMI/ISO 11137 norm, which defines the requirements and standard practices for validation of the irradiation process and the process controls required during routine processing

  18. Experimental studies of electron capture

    International Nuclear Information System (INIS)

    Pedersen, E.H.

    1983-01-01

    This thesis discusses the main results of recent experimental studies of electron capture in asymmetric collisions. Most of the results have been published, but the thesis also contains yet unpublished data, or data presented only in unrefereed conference proceedings. The thesis aims at giving a coherent discussion of the understanding of the experimental results, based first on simple qualitative considerations and subsequently on quantitative comparisons with the best theoretical calculations currently available. (Auth.)

  19. Validating the Technology Acceptance Model in the Context of the Laboratory Information System-Electronic Health Record Interface System

    Science.gov (United States)

    Aquino, Cesar A.

    2014-01-01

    This study represents a research validating the efficacy of Davis' Technology Acceptance Model (TAM) by pairing it with the Organizational Change Readiness Theory (OCRT) to develop another extension to the TAM, using the medical Laboratory Information Systems (LIS)--Electronic Health Records (EHR) interface as the medium. The TAM posits that it is…

  20. BIOMOVS: an international model validation study

    International Nuclear Information System (INIS)

    Haegg, C.; Johansson, G.

    1988-01-01

    BIOMOVS (BIOspheric MOdel Validation Study) is an international study where models used for describing the distribution of radioactive and nonradioactive trace substances in terrestrial and aquatic environments are compared and tested. The main objectives of the study are to compare and test the accuracy of predictions between such models, explain differences in these predictions, recommend priorities for future research concerning the improvement of the accuracy of model predictions and act as a forum for the exchange of ideas, experience and information. (author)

  1. BIOMOVS: An international model validation study

    International Nuclear Information System (INIS)

    Haegg, C.; Johansson, G.

    1987-01-01

    BIOMOVS (BIOspheric MOdel Validation Study) is an international study where models used for describing the distribution of radioactive and nonradioactive trace substances in terrestrial and aquatic environments are compared and tested. The main objectives of the study are to compare and test the accuracy of predictions between such models, explain differences in these predictions, recommend priorities for future research concerning the improvement of the accuracy of model predictions and act as a forum for the exchange of ideas, experience and information. (orig.)

  2. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ming, W.Q.; Chen, J.H., E-mail: jhchen123@hnu.edu.cn

    2013-11-15

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations.

  3. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    International Nuclear Information System (INIS)

    Ming, W.Q.; Chen, J.H.

    2013-01-01

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations

  4. [Support of the nursing process through electronic nursing documentation systems (UEPD) – Initial validation of an instrument].

    Science.gov (United States)

    Hediger, Hannele; Müller-Staub, Maria; Petry, Heidi

    2016-01-01

    Electronic nursing documentation systems, with standardized nursing terminology, are IT-based systems for recording the nursing processes. These systems have the potential to improve the documentation of the nursing process and to support nurses in care delivery. This article describes the development and initial validation of an instrument (known by its German acronym UEPD) to measure the subjectively-perceived benefits of an electronic nursing documentation system in care delivery. The validity of the UEPD was examined by means of an evaluation study carried out in an acute care hospital (n = 94 nurses) in German-speaking Switzerland. Construct validity was analyzed by principal components analysis. Initial references of validity of the UEPD could be verified. The analysis showed a stable four factor model (FS = 0.89) scoring in 25 items. All factors loaded ≥ 0.50 and the scales demonstrated high internal consistency (Cronbach's α = 0.73 – 0.90). Principal component analysis revealed four dimensions of support: establishing nursing diagnosis and goals; recording a case history/an assessment and documenting the nursing process; implementation and evaluation as well as information exchange. Further testing with larger control samples and with different electronic documentation systems are needed. Another potential direction would be to employ the UEPD in a comparison of various electronic documentation systems.

  5. Study of single-electron excitations by electron microscopy

    International Nuclear Information System (INIS)

    Craven, A.J.; Gibson, J.M.; Howie, A.; Spalding, D.R.

    1978-01-01

    The inelastic scattering of fast electrons by the excitation of L-shell electrons at a stacking fault in silicon has been studied with a scanning transmission electron microscope. It was found that the bright-field stacking fault contrast is preserved in the filtered L-shell-loss signal at 100 eV. This result is discussed in terms of the delocalization of the excitation mechanism. It is concluded that localization effects will typically become significant only for energy transfers greater than 1 keV from a fast electron of energy 80 keV. (author)

  6. Validation of multisource electronic health record data: an application to blood transfusion data.

    Science.gov (United States)

    Hoeven, Loan R van; Bruijne, Martine C de; Kemper, Peter F; Koopman, Maria M W; Rondeel, Jan M M; Leyte, Anja; Koffijberg, Hendrik; Janssen, Mart P; Roes, Kit C B

    2017-07-14

    Although data from electronic health records (EHR) are often used for research purposes, systematic validation of these data prior to their use is not standard practice. Existing validation frameworks discuss validity concepts without translating these into practical implementation steps or addressing the potential influence of linking multiple sources. Therefore we developed a practical approach for validating routinely collected data from multiple sources and to apply it to a blood transfusion data warehouse to evaluate the usability in practice. The approach consists of identifying existing validation frameworks for EHR data or linked data, selecting validity concepts from these frameworks and establishing quantifiable validity outcomes for each concept. The approach distinguishes external validation concepts (e.g. concordance with external reports, previous literature and expert feedback) and internal consistency concepts which use expected associations within the dataset itself (e.g. completeness, uniformity and plausibility). In an example case, the selected concepts were applied to a transfusion dataset and specified in more detail. Application of the approach to a transfusion dataset resulted in a structured overview of data validity aspects. This allowed improvement of these aspects through further processing of the data and in some cases adjustment of the data extraction. For example, the proportion of transfused products that could not be linked to the corresponding issued products initially was 2.2% but could be improved by adjusting data extraction criteria to 0.17%. This stepwise approach for validating linked multisource data provides a basis for evaluating data quality and enhancing interpretation. When the process of data validation is adopted more broadly, this contributes to increased transparency and greater reliability of research based on routinely collected electronic health records.

  7. The validity of the density scaling method in primary electron transport for photon and electron beams

    International Nuclear Information System (INIS)

    Woo, M.K.; Cunningham, J.R.

    1990-01-01

    In the convolution/superposition method of photon beam dose calculations, inhomogeneities are usually handled by using some form of scaling involving the relative electron densities of the inhomogeneities. In this paper the accuracy of density scaling as applied to primary electrons generated in photon interactions is examined. Monte Carlo calculations are compared with density scaling calculations for air and cork slab inhomogeneities. For individual primary photon kernels as well as for photon interactions restricted to a thin layer, the results can differ significantly, by up to 50%, between the two calculations. However, for realistic photon beams where interactions occur throughout the whole irradiated volume, the discrepancies are much less severe. The discrepancies for the kernel calculation are attributed to the scattering characteristics of the electrons and the consequent oversimplified modeling used in the density scaling method. A technique called the kernel integration technique is developed to analyze the general effects of air and cork inhomogeneities. It is shown that the discrepancies become significant only under rather extreme conditions, such as immediately beyond the surface after a large air gap. In electron beams all the primary electrons originate from the surface of the phantom and the errors caused by simple density scaling can be much more significant. Various aspects relating to the accuracy of density scaling for air and cork slab inhomogeneities are discussed

  8. Feasibility study for mega-electron-volt electron beam tomography.

    Science.gov (United States)

    Hampel, U; Bärtling, Y; Hoppe, D; Kuksanov, N; Fadeev, S; Salimov, R

    2012-09-01

    Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

  9. Online crowdsourcing for efficient rating of speech: a validation study.

    Science.gov (United States)

    McAllister Byun, Tara; Halpin, Peter F; Szeredi, Daniel

    2015-01-01

    Blinded listener ratings are essential for valid assessment of interventions for speech disorders, but collecting these ratings can be time-intensive and costly. This study evaluated the validity of speech ratings obtained through online crowdsourcing, a potentially more efficient approach. 100 words from children with /r/ misarticulation were electronically presented for binary rating by 35 phonetically trained listeners and 205 naïve listeners recruited through the Amazon Mechanical Turk (AMT) crowdsourcing platform. Bootstrapping was used to compare different-sized samples of AMT listeners against a "gold standard" (mode across all trained listeners) and an "industry standard" (mode across bootstrapped samples of three trained listeners). There was strong overall agreement between trained and AMT listeners. The "industry standard" level of performance was matched by bootstrapped samples with n = 9 AMT listeners. These results support the hypothesis that valid ratings of speech data can be obtained in an efficient manner through AMT. Researchers in communication disorders could benefit from increased awareness of this method. Readers will be able to (a) discuss advantages and disadvantages of data collection through the crowdsourcing platform Amazon Mechanical Turk (AMT), (b) describe the results of a validity study comparing samples of AMT listeners versus phonetically trained listeners in a speech-rating task. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Validation of a Delirium Risk Assessment Using Electronic Medical Record Information.

    Science.gov (United States)

    Rudolph, James L; Doherty, Kelly; Kelly, Brittany; Driver, Jane A; Archambault, Elizabeth

    2016-03-01

    Identifying patients at risk for delirium allows prompt application of prevention, diagnostic, and treatment strategies; but is rarely done. Once delirium develops, patients are more likely to need posthospitalization skilled care. This study developed an a priori electronic prediction rule using independent risk factors identified in a National Center of Clinical Excellence meta-analysis and validated the ability to predict delirium in 2 cohorts. Retrospective analysis followed by prospective validation. Tertiary VA Hospital in New England. A total of 27,625 medical records of hospitalized patients and 246 prospectively enrolled patients admitted to the hospital. The electronic delirium risk prediction rule was created using data obtained from the patient electronic medical record (EMR). The primary outcome, delirium, was identified 2 ways: (1) from the EMR (retrospective cohort) and (2) clinical assessment on enrollment and daily thereafter (prospective participants). We assessed discrimination of the delirium prediction rule with the C-statistic. Secondary outcomes were length of stay and discharge to rehabilitation. Retrospectively, delirium was identified in 8% of medical records (n = 2343); prospectively, delirium during hospitalization was present in 26% of participants (n = 64). In the retrospective cohort, medical record delirium was identified in 2%, 3%, 11%, and 38% of the low, intermediate, high, and very high-risk groups, respectively (C-statistic = 0.81; 95% confidence interval 0.80-0.82). Prospectively, the electronic prediction rule identified delirium in 15%, 18%, 31%, and 55% of these groups (C-statistic = 0.69; 95% confidence interval 0.61-0.77). Compared with low-risk patients, those at high- or very high delirium risk had increased length of stay (5.7 ± 5.6 vs 3.7 ± 2.7 days; P = .001) and higher rates of discharge to rehabilitation (8.9% vs 20.8%; P = .02). Automatic calculation of delirium risk using an EMR algorithm identifies patients at

  11. Studying electron-PAG interactions using electron-induced fluorescence

    Science.gov (United States)

    Narasimhan, Amrit; Grzeskowiak, Steven; Ostrander, Jonathan; Schad, Jonathon; Rebeyev, Eliran; Neisser, Mark; Ocola, Leonidas E.; Denbeaux, Gregory; Brainard, Robert L.

    2016-03-01

    In extreme ultraviolet (EUV) lithography, 92 eV photons are used to expose photoresists. Typical EUV resists are organic-based and chemically amplified using photoacid generators (PAGs). Upon exposure, PAGs produce acids which catalyze reactions that result in changes in solubility. In EUV lithography, photo- and secondary electrons (energies of 10- 80 eV) play a large role in PAG acid-production. Several mechanisms for electron-PAG interactions (e.g. electron trapping, and hole-initiated chemistry) have been proposed. The aim of this study is to explore another mechanism - internal excitation - in which a bound PAG electron can be excited by receiving energy from another energetic electron, causing a reaction that produces acid. This paper explores the mechanism of internal excitation through the analogous process of electron-induced fluorescence, in which an electron loses energy by transferring that energy to a molecule and that molecule emits a photon rather than decomposing. We will show and quantify electron-induced fluorescence of several fluorophores in polymer films to mimic resist materials, and use this information to refine our proposed mechanism. Relationships between the molecular structure of fluorophores and fluorescent quantum yield may aid in the development of novel PAGs for EUV lithography.

  12. Oblique electron cyclotron emission for electron distribution studies (invited)

    International Nuclear Information System (INIS)

    Preische, S.; Efthimion, P.C.; Kaye, S.M.

    1997-01-01

    Electron cyclotron emission (ECE) at an oblique angle to the magnetic field provides a means of probing the electron distribution function both in energy and physical space through changes in and constraints on the relativistic electron cyclotron resonance condition. Diagnostics based on this Doppler shifted resonance are able to study a variety of electron distributions through changes in the location of the resonance in physical or energy space accomplished by changes in the viewing angle and frequency, and the magnetic field. For the case of observation across a changing magnetic field, such as across the tokamak midplane, the constraint on the resonance condition for real solutions to the dispersion relation can constrain the physical location of optically thin emission. A new Oblique ECE diagnostic was installed and operated on the PBX-M tokamak for the study of energetic electrons during lower hybrid current drive. It has a view 33 degree with respect to perpendicular in the tokamak midplane, receives second harmonic X-mode emission, and is constrained to receive single pass emission by SiC viewing dumps on the tokamak walls. Spatial localization of optically thin emission from superthermal electrons (50 endash 100 keV) was obtained by observation of emission upshifted from a thermal cyclotron harmonic. The localized measurements of the electron energy distribution and the superthermal density profile made by this diagnostic demonstrate its potential to study the spatial transport of energetic electrons on fast magnetohydrodynamic time scales or anomalous diffusion time scales. Oblique ECE can also be used to study electron distributions that may have a slight deviation from a Maxwellian by localizing the emission in energy space. (Abstract Truncated)

  13. Validation of honey-bee smelling profile by using a commercial electronic nose

    Directory of Open Access Journals (Sweden)

    Ana R. Correa

    2017-09-01

    Full Text Available Honey is a natural sweetener and its quality labels are associated to its botanical or geographical origin, which is being established by palynological and sensorial analysis. The use of fast and non-invasive techniques such as an electronic nose can become an alternative for honey classification. In this study, the operational parameters of a commercial electronic nose were validated to determine the honey odor profile. A central composite design with five factors, three levels and 28 assays was used, varying sample amounts (1, 2 and 3 g, incubation temperature (30, 40 and 50 °C, incubation time 30 min, gas flow (50, 150 and 250 mL/min and injection time (100, 200 and 300 s. The commercial nose had ten sensors. Repeatability was evaluated with a coefficient of variation of 10 %. The response surface methodology was used and the optimal operating conditions were: 3 g of sample, incubation at 50 °C for 17 min, gas flow of 100 mL/min and sampling time of 150 s. Finally, these parameters were used to analyze 19 samples of honey, which were classified according to their odor profiles, showing that it can be a useful tool to classify honey.

  14. Electronic study books and learning style

    NARCIS (Netherlands)

    de Diana, I.P.F.; van der Heiden, G.

    1994-01-01

    Attention has been drawn to the concepts of Electronic Books and Electronic Study Books. Several publications have discussed some main ideas (paradigms) for both concepts. For the Electronic Study Book as a learning environment, it is essential to consider individual modes of learning, usually

  15. Discriminant validity study of Achilles enthesis ultrasound.

    Science.gov (United States)

    Expósito Molinero, María Rosa; de Miguel Mendieta, Eugenio

    2016-01-01

    We want to know if the ultrasound examination of the Achilles tendon in spondyloarthritis is different compared to other rheumatic diseases. We studied 97 patients divided into five groups: rheumatoid arthritis, spondyloarthritis, gout, chondrocalcinosis and osteoarthritis, exploring six elementary lesions in 194 Achilles entheses examined. In our study the total index ultrasonographic Achilles is higher in spondyloarthritis with significant differences. The worst elementary spondyloarthritis lesions for discriminations against other pathologies were calcification. This study aims to demonstrate the discriminant validity of Achilles enthesitis observed by ultrasound in spondyloarthritis compared with other rheumatic diseases that may also have ultrasound abnormalities such enthesis level. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  16. Semantic validation of standard-based electronic health record documents with W3C XML schema.

    Science.gov (United States)

    Rinner, C; Janzek-Hawlat, S; Sibinovic, S; Duftschmid, G

    2010-01-01

    The goal of this article is to examine whether W3C XML Schema provides a practicable solution for the semantic validation of standard-based electronic health record (EHR) documents. With semantic validation we mean that the EHR documents are checked for conformance with the underlying archetypes and reference model. We describe an approach that allows XML Schemas to be derived from archetypes based on a specific naming convention. The archetype constraints are augmented with additional components of the reference model within the XML Schema representation. A copy of the EHR document that is transformed according to the before-mentioned naming convention is used for the actual validation against the XML Schema. We tested our approach by semantically validating EHR documents conformant to three different ISO/EN 13606 archetypes respective to three sections of the CDA implementation guide "Continuity of Care Document (CCD)" and an implementation guide for diabetes therapy data. We further developed a tool to automate the different steps of our semantic validation approach. For two particular kinds of archetype prescriptions, individual transformations are required for the corresponding EHR documents. Otherwise, a fully generic validation is possible. In general, we consider W3C XML Schema as a practicable solution for the semantic validation of standard-based EHR documents.

  17. Studies of electron cyclotron emission on text

    International Nuclear Information System (INIS)

    Gandy, R.F.

    1990-07-01

    The Auburn University electron cyclotron emission (ECE) system has made many significant contributions to the TEXT experimental program during the past five years. Contributions include electron temperature information used in the following areas of study: electron cyclotron heating (ECH), pellet injection, and impurity/energy transport. Details of the role which the Auburn ECE system has played will now be discussed

  18. Validation of exhaled volatile organic compounds analysis using electronic nose as index of COPD severity

    Directory of Open Access Journals (Sweden)

    Finamore P

    2018-05-01

    Full Text Available Panaiotis Finamore,1 Claudio Pedone,1 Simone Scarlata,1 Alessandra Di Paolo,1 Simone Grasso,2 Marco Santonico,2 Giorgio Pennazza,2 Raffaele Antonelli Incalzi1 1Unit of Geriatrics, Campus Bio-Medico di Roma University, Rome, Italy; 2Unit of Electronics for Sensor Systems, Campus Bio-Medico di Roma University, Rome, Italy Aim: Six-minute walking test distance (6MWD and body mass index, obstruction, dyspnea and exercise (BODE index are measures of functional status in COPD patients, but require space, time and patient’s compliance. Exhaled volatile organic compounds (VOCs analysis via electronic nose is a quick and easy method that has already been used to discriminate COPD phenotypes. The aim of this study is to evaluate whether VOCs analysis can predict functional status and its variation over time in COPD patients.Methods: A monocentric prospective study with 1 year of follow-up was carried out. All patients underwent pulmonary function tests, arterial gas analysis, bioimpedance analysis, 6-minute walking test, and VOCs collection. Exhaled breath was collected with Pneumopipe® and analyzed using BIONOTE electronic nose. Outcomes prediction was performed by k-fold cross-validated partial least square discriminant analysis: accuracy, sensitivity and specificity as well as Cohen’s kappa for agreement were calculated.Results: We enrolled 63 patients, 60.3% men, with a mean age of 71 (SD: 8 years, median BODE index of 1 (interquartile range: 0–3 and mean 6MWD normalized by squared height (n6MWD of 133.5 (SD: 42 m/m2. The BIONOTE predicted baseline BODE score (dichotomized as BODE score <3 or ≥3 with an accuracy of 86% and quartiles of n6MWD with an accuracy of 79%. n6MWD decline more than the median value after 1 year was predicted with an accuracy of 86% by BIONOTE, 52% by Global Initiative for Chronic Obstructive Lung Disease (GOLD class and 78% by combined BIONOTE and GOLD class.Conclusion: Exhaled VOCs analysis identifies classes of BODE

  19. Standardisation And Validation Study Of A New Study Skills ...

    African Journals Online (AJOL)

    Concerns have also been raised by various researchers about the latent constructs of existing western scales to assess study skills. The objective of this study was to develop, standardize and validate a culturally sensitive study skills questionnaire (SSQ). Methods: a stratified random sample of secondary school students (n ...

  20. Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients

    Directory of Open Access Journals (Sweden)

    Steiger Jürg

    2008-02-01

    Full Text Available Abstract Background Electronic monitoring (EM is used increasingly to measure medication non-adherence. Unbiased EM assessment requires fulfillment of assumptions. The purpose of this study was to determine assumptions needed for internal and external validity of EM measurement. To test internal validity, we examined if (1 EM equipment functioned correctly, (2 if all EM bottle openings corresponded to actual drug intake, and (3 if EM did not influence a patient's normal adherence behavior. To assess external validity, we examined if there were indications that using EM affected the sample representativeness. Methods We used data from the Supporting Medication Adherence in Renal Transplantation (SMART study, which included 250 adult renal transplant patients whose adherence to immunosuppressive drugs was measured during 3 months with the Medication Event Monitoring System (MEMS. Internal validity was determined by assessing the prevalence of nonfunctioning EM systems, the prevalence of patient-reported discrepancies between cap openings and actual intakes (using contemporaneous notes and interview at the end of the study, and by exploring whether adherence was initially uncharacteristically high and decreased over time (an indication of a possible EM intervention effect. Sample representativeness was examined by screening for differences between participants and non-participants or drop outs on non-adherence. Results Our analysis revealed that some assumptions were not fulfilled: 1 one cap malfunctioned (0.4%, 2 self-reported mismatches between bottle openings and actual drug intake occurred in 62% of the patients (n = 155, and 3 adherence decreased over the first 5 weeks of the monitoring, indicating that EM had a waning intervention effect. Conclusion The validity assumptions presented in this article should be checked in future studies using EM as a measure of medication non-adherence.

  1. Validating Smoking Data From the Veteran’s Affairs Health Factors Dataset, an Electronic Data Source

    Science.gov (United States)

    Brandt, Cynthia A.; Skanderson, Melissa; Justice, Amy C.; Shahrir, Shahida; Butt, Adeel A.; Brown, Sheldon T.; Freiberg, Matthew S.; Gibert, Cynthia L.; Goetz, Matthew Bidwell; Kim, Joon Woo; Pisani, Margaret A.; Rimland, David; Rodriguez-Barradas, Maria C.; Sico, Jason J.; Tindle, Hilary A.; Crothers, Kristina

    2011-01-01

    Introduction: We assessed smoking data from the Veterans Health Administration (VHA) electronic medical record (EMR) Health Factors dataset. Methods: To assess the validity of the EMR Health Factors smoking data, we first created an algorithm to convert text entries into a 3-category smoking variable (never, former, and current). We compared this EMR smoking variable to 2 different sources of patient self-reported smoking survey data: (a) 6,816 HIV-infected and -uninfected participants in the 8-site Veterans Aging Cohort Study (VACS-8) and (b) a subset of 13,689 participants from the national VACS Virtual Cohort (VACS-VC), who also completed the 1999 Large Health Study (LHS) survey. Sensitivity, specificity, and kappa statistics were used to evaluate agreement of EMR Health Factors smoking data with self-report smoking data. Results: For the EMR Health Factors and VACS-8 comparison of current, former, and never smoking categories, the kappa statistic was .66. For EMR Health Factors and VACS-VC/LHS comparison of smoking, the kappa statistic was .61. Conclusions: Based on kappa statistics, agreement between the EMR Health Factors and survey sources is substantial. Identification of current smokers nationally within the VHA can be used in future studies to track smoking status over time, to evaluate smoking interventions, and to adjust for smoking status in research. Our methodology may provide insights for other organizations seeking to use EMR data for accurate determination of smoking status. PMID:21911825

  2. Derivation and validation of the automated search algorithms to identify cognitive impairment and dementia in electronic health records.

    Science.gov (United States)

    Amra, Sakusic; O'Horo, John C; Singh, Tarun D; Wilson, Gregory A; Kashyap, Rahul; Petersen, Ronald; Roberts, Rosebud O; Fryer, John D; Rabinstein, Alejandro A; Gajic, Ognjen

    2017-02-01

    Long-term cognitive impairment is a common and important problem in survivors of critical illness. We developed electronic search algorithms to identify cognitive impairment and dementia from the electronic medical records (EMRs) that provide opportunity for big data analysis. Eligible patients met 2 criteria. First, they had a formal cognitive evaluation by The Mayo Clinic Study of Aging. Second, they were hospitalized in intensive care unit at our institution between 2006 and 2014. The "criterion standard" for diagnosis was formal cognitive evaluation supplemented by input from an expert neurologist. Using all available EMR data, we developed and improved our algorithms in the derivation cohort and validated them in the independent validation cohort. Of 993 participants who underwent formal cognitive testing and were hospitalized in intensive care unit, we selected 151 participants at random to form the derivation and validation cohorts. The automated electronic search algorithm for cognitive impairment was 94.3% sensitive and 93.0% specific. The search algorithms for dementia achieved respective sensitivity and specificity of 97% and 99%. EMR search algorithms significantly outperformed International Classification of Diseases codes. Automated EMR data extractions for cognitive impairment and dementia are reliable and accurate and can serve as acceptable and efficient alternatives to time-consuming manual data review. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Transmission electron microscope studies of extraterrestrial materials

    Science.gov (United States)

    Keller, Lindsay P.

    1995-01-01

    Transmission Electron Microscopy, X-Ray spectrometry and electron-energy-loss spectroscopy are used to analyse carbon in interplanetary dust particles. Optical micrographs are shown depicting cross sections of the dust particles embedded in sulphur. Selected-area electron diffraction patterns are shown. Transmission Electron Microscope specimens of lunar soil were prepared using two methods: ion-milling and ultramicrotomy. A combination of high resolution TEM imaging and electron diffraction is used to characterize the opaque assemblages. The opaque assemblages analyzed in this study are dominated by ilmenite with lesser rutile and spinel exsolutions, and traces of Fe metal.

  4. Study and impact of fast electrons diagnosed by electron cyclotron radiation on Tore-Supra tokamak

    International Nuclear Information System (INIS)

    Gomez, P.

    1999-12-01

    This thesis aims at characterizing the dynamics of fast electrons generated by the Landau absorption of the hybrid wave and studying their effects on electron cyclotron radiation. The different processes involved in the propagation and resonant absorption of the hybrid wave in plasmas are described. A method such as ray-tracing allows the characterization of the dynamics of heating but this method relies on the hypothesis of geometrical optics. Whenever absorption rate is low as it is in Tore-Supra, the hybrid wave undergoes a series of successive reflections on the edge of the plasma before being completely absorbed. These reflections generate an electromagnetic chaos in which geometrical optics hypothesis are no longer valid. A statistical treatment of the Fokker-Planck equation allows the calculation of the mean distribution function of electrons in the plasma submitted to hybrid wave. The electron cyclotron radiation is then deduced and by assuming that plasma behaves like a black body, a theoretical radiative temperature is calculated. The confrontation of this theoretical temperature profile with experimental values allows the validation of this modeling and the estimation of the effects of fast electrons on temperature measurements. (A.C.)

  5. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  6. Molecular dynamics-based refinement and validation for sub-5 Å cryo-electron microscopy maps.

    Science.gov (United States)

    Singharoy, Abhishek; Teo, Ivan; McGreevy, Ryan; Stone, John E; Zhao, Jianhua; Schulten, Klaus

    2016-07-07

    Two structure determination methods, based on the molecular dynamics flexible fitting (MDFF) paradigm, are presented that resolve sub-5 Å cryo-electron microscopy (EM) maps with either single structures or ensembles of such structures. The methods, denoted cascade MDFF and resolution exchange MDFF, sequentially re-refine a search model against a series of maps of progressively higher resolutions, which ends with the original experimental resolution. Application of sequential re-refinement enables MDFF to achieve a radius of convergence of ~25 Å demonstrated with the accurate modeling of β-galactosidase and TRPV1 proteins at 3.2 Å and 3.4 Å resolution, respectively. The MDFF refinements uniquely offer map-model validation and B-factor determination criteria based on the inherent dynamics of the macromolecules studied, captured by means of local root mean square fluctuations. The MDFF tools described are available to researchers through an easy-to-use and cost-effective cloud computing resource on Amazon Web Services.

  7. Training and Validating a Portable Electronic Nose for Lung Cancer Screening.

    Science.gov (United States)

    van de Goor, Rens; van Hooren, Michel; Dingemans, Anne-Marie; Kremer, Bernd; Kross, Kenneth

    2018-05-01

    Profiling volatile organic compounds in exhaled breath enables the diagnosis of several types of cancer. In this study we investigated whether a portable point-of-care version of an electronic nose (e-nose) (Aeonose, [eNose Company, Zutphen, the Netherlands]) is able to discriminate between patients with lung cancer and healthy controls on the basis of their volatile organic compound pattern. In this study, we used five e-nose devices to collect breath samples from patients with lung cancer and healthy controls. A total of 60 patients with lung cancer and 107 controls exhaled through an e-nose for 5 minutes. Patients were assigned either to a training group for building an artificial neural network model or to a blinded control group for validating this model. For differentiating patients with lung cancer from healthy controls, the results showed a diagnostic accuracy of 83% with a sensitivity of 83%, specificity of 84%, and area under the curve of 0.84. Results for the blinded group showed comparable results, with a sensitivity of 88%, specificity of 86%, and diagnostic accuracy of 86%. This feasibility study showed that this portable e-nose can properly differentiate between patients with lung cancer and healthy controls. This result could have important implications for future lung cancer screening. Further studies with larger cohorts, including also more participants with early-stage tumors, should be performed to increase the robustness of this noninvasive diagnostic tool and to determine its added value in the diagnostic chain for lung cancer. Copyright © 2018 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  8. Electron Temperature Fluctuation Measurements and Transport Model Validation at Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    White, Anne [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2017-06-22

    The tokamak is a type of toroidal device used to confine a fusion plasma using large magnetic fields. Tokamaks and stellarators the leading devices for confining plasmas for fusion, and the capability to predict performance in these magnetically confined plasmas is essential for developing a sustainable fusion energy source. The magnetic configuration of tokamaks and stellarators does not exist in Nature, yet, the fundamental processes governing transport in fusion plasmas are universal – turbulence and instabilities, driven by inhomogeneity and asymmetry in the plasma, conspire to transport heat and particles across magnetic field lines and can play critical roles in impurity confinement and generation of intrinsic rotation. Turbulence exists in all plasmas, and in neutral fluids as well. The study of turbulence is essential to developing a fundamental understanding of the nature of the fourth state of matter, plasmas. Experimental studies of turbulence in tokamaks date back to early scattering observations from the late 1970s. Since that time, great advances in turbulence diagnostics have been made, all of which have significantly enhanced our knowledge and understanding of turbulence in tokamaks. Through comparisons with advanced gyrokinetic theory and turbulent-transport models a great deal of evidence exists to implicate turbulent-driven transport as an important mechanism determining transport in all channels: heat, particle and momentum However, prediction and control of turbulent-driven transport remains elusive. Key to development of predictive transport models for magnetically confined fusion plasmas is validation of the nonlinear gyrokinetic transport model, which describes transport due to turbulence. Validation of gyrokinetic codes must include detailed and quantitative comparisons with measured turbulence characteristics, in addition to comparisons with inferred transport levels and equilibrium profiles. For this reason, advanced plasma diagnostics

  9. Card - Electronic Money. Comparative Study

    Directory of Open Access Journals (Sweden)

    Mariana Rodica TIRLEA

    2012-11-01

    Full Text Available This type of coin and appeared as a result of the needs for a proper management of the financial resources available in the market, but also to improve the payments system in our country. The card is an alternative to the conventional instruments of payment is a payment instrument with and without cash by means of which the holder disposes of the current account. It is a standardized, secure information and individualized, through which you can perform operations of cash withdrawal, payment for the goods or services purchased, payment obligations by the public administration authorities and funds transfers between accounts, other than those ordered and executed by financial institutions, carried out through the electronic payment instrument.

  10. A kinetic study of solar wind electrons

    International Nuclear Information System (INIS)

    Lie-Svendsen, Oeystein; Leer, Egil

    1996-01-01

    The evolution of the distribution function for a test population of electrons in an isothermal electron-proton corona has been studied using a Fokker-Planck description. The aim is to investigate whether a suprathermal tail forms due to the energy dependence of the Coulomb cross section. We find that a Maxwellian test population, injected into this background close to the coronal base with a temperature equal to that of the background electrons, maintains its shape throughout the transition from collision-dominated to collisionless flow. No significant suprathermal tail in the electron distribution function is seen in the outer corona

  11. Electronic and optical properties of Fe, Pd, and Ti studied by reflection electron energy loss spectroscopy

    International Nuclear Information System (INIS)

    Tahir, Dahlang; Kraaer, Jens; Tougaard, Sven

    2014-01-01

    We have studied the electronic and optical properties of Fe, Pd, and Ti by reflection electron energy-loss spectroscopy (REELS). REELS spectra recorded for primary energies in the range from 300 eV to 10 keV were corrected for multiple inelastically scattered electrons to determine the effective inelastic-scattering cross section. The dielectric functions and optical properties were determined by comparing the experimental inelastic-electron scattering cross section with a simulated cross section calculated within the semi-classical dielectric response model in which the only input is Im(−1/ε) by using the QUEELS-ε(k,ω)-REELS software package. The complex dielectric functions ε(k,ω), in the 0–100 eV energy range, for Fe, Pd, and Ti were determined from the derived Im(−1/ε) by Kramers-Kronig transformation and then the refractive index n and extinction coefficient k. The validity of the applied model was previously tested and found to give consistent results when applied to REELS spectra at energies between 300 and 1000 eV taken at widely different experimental geometries. In the present paper, we provide, for the first time, a further test on its validity and find that the model also gives consistent results when applied to REELS spectra in the full range of primary electron energies from 300 eV to 10000 eV. This gives confidence in the validity of the applied method.

  12. Student Off-Task Electronic Multitasking Predictors: Scale Development and Validation

    Science.gov (United States)

    Qian, Yuxia; Li, Li

    2017-01-01

    In an attempt to better understand factors contributing to students' off-task electronic multitasking behavior in class, the research included two studies that developed a scale of students' off-task electronic multitasking predictors (the SOTEMP scale), and explored relationships between the scale and various classroom communication processes and…

  13. Validation of an Improved Computer-Assisted Technique for Mining Free-Text Electronic Medical Records.

    Science.gov (United States)

    Duz, Marco; Marshall, John F; Parkin, Tim

    2017-06-29

    The use of electronic medical records (EMRs) offers opportunity for clinical epidemiological research. With large EMR databases, automated analysis processes are necessary but require thorough validation before they can be routinely used. The aim of this study was to validate a computer-assisted technique using commercially available content analysis software (SimStat-WordStat v.6 (SS/WS), Provalis Research) for mining free-text EMRs. The dataset used for the validation process included life-long EMRs from 335 patients (17,563 rows of data), selected at random from a larger dataset (141,543 patients, ~2.6 million rows of data) and obtained from 10 equine veterinary practices in the United Kingdom. The ability of the computer-assisted technique to detect rows of data (cases) of colic, renal failure, right dorsal colitis, and non-steroidal anti-inflammatory drug (NSAID) use in the population was compared with manual classification. The first step of the computer-assisted analysis process was the definition of inclusion dictionaries to identify cases, including terms identifying a condition of interest. Words in inclusion dictionaries were selected from the list of all words in the dataset obtained in SS/WS. The second step consisted of defining an exclusion dictionary, including combinations of words to remove cases erroneously classified by the inclusion dictionary alone. The third step was the definition of a reinclusion dictionary to reinclude cases that had been erroneously classified by the exclusion dictionary. Finally, cases obtained by the exclusion dictionary were removed from cases obtained by the inclusion dictionary, and cases from the reinclusion dictionary were subsequently reincluded using Rv3.0.2 (R Foundation for Statistical Computing, Vienna, Austria). Manual analysis was performed as a separate process by a single experienced clinician reading through the dataset once and classifying each row of data based on the interpretation of the free

  14. Valid Probabilistic Predictions for Ginseng with Venn Machines Using Electronic Nose

    Directory of Open Access Journals (Sweden)

    You Wang

    2016-07-01

    Full Text Available In the application of electronic noses (E-noses, probabilistic prediction is a good way to estimate how confident we are about our prediction. In this work, a homemade E-nose system embedded with 16 metal-oxide semi-conductive gas sensors was used to discriminate nine kinds of ginsengs of different species or production places. A flexible machine learning framework, Venn machine (VM was introduced to make probabilistic predictions for each prediction. Three Venn predictors were developed based on three classical probabilistic prediction methods (Platt’s method, Softmax regression and Naive Bayes. Three Venn predictors and three classical probabilistic prediction methods were compared in aspect of classification rate and especially the validity of estimated probability. A best classification rate of 88.57% was achieved with Platt’s method in offline mode, and the classification rate of VM-SVM (Venn machine based on Support Vector Machine was 86.35%, just 2.22% lower. The validity of Venn predictors performed better than that of corresponding classical probabilistic prediction methods. The validity of VM-SVM was superior to the other methods. The results demonstrated that Venn machine is a flexible tool to make precise and valid probabilistic prediction in the application of E-nose, and VM-SVM achieved the best performance for the probabilistic prediction of ginseng samples.

  15. Italian version of Dyspnoea-12: cultural-linguistic validation, quantitative and qualitative content validity study.

    Science.gov (United States)

    Caruso, Rosario; Arrigoni, Cristina; Groppelli, Katia; Magon, Arianna; Dellafiore, Federica; Pittella, Francesco; Grugnetti, Anna Maria; Chessa, Massimo; Yorke, Janelle

    2018-01-16

    Dyspnoea-12 is a valid and reliable scale to assess dyspneic symptom, considering its severity, physical and emotional components. However, it is not available in Italian version due to it was not yet translated and validated. For this reason, the aim of this study was to develop an Italian version Dyspnoea-12, providing a cultural and linguistic validation, supported by the quantitative and qualitative content validity. This was a methodological study, divided into two phases: phase one is related to the cultural and linguistic validation, phase two is related to test the quantitative and qualitative content validity. Linguistic validation followed a standardized translation process. Quantitative content validity was assessed computing content validity ratio (CVR) and index (I-CVIs and S-CVI) from expert panellists response. Qualitative content validity was assessed by the narrative analysis on the answers of three open-ended questions to the expert panellists, aimed to investigate the clarity and the pertinence of the Italian items. The translation process found a good agreement in considering clear the items in both the six involved bilingual expert translators and among the ten voluntary involved patients. CVR, I-CVIs and S-CVI were satisfactory for all the translated items. This study has represented a pivotal step to use Dyspnoea-12 amongst Italian patients. Future researches are needed to deeply investigate the Italian version of  Dyspnoea-12 construct validity and its reliability, and to describe how dyspnoea components (i.e. physical and emotional) impact the life of patients with cardiorespiratory diseases.

  16. The measurement, control, and validation of critical parameters in an electron beam sterilization facility

    International Nuclear Information System (INIS)

    Burns, P.; Drewell, N.H.; McKeown, J.

    1996-01-01

    The delivery and validation of a specified dose to a medical device are key concerns of operators of electron beam irradiation facilities. In an IMPELA-based irradiator, four of the parameters that directly influence the absorbed dose distribution in the product are controllable in real time - the electron energy, average beam current, scanned area, and the product exposure time. The 10 MeV accelerator operates at 50 kW with a stream of 200 μs wide, 100 mA pulses at a repetition rate of 250 Hz. The combination of short-term intra-pulse regulation with long-term pulse-to-pulse stability makes the IMPELA output attractive for the sterilization of medical products. The measurement and closed-loop control techniques used in the IMPELA design will be described with reference to facilitating compliance with medical sterilization standards. (orig.)

  17. Electronic self-monitoring of mood using IT platforms in adult patients with bipolar disorder: A systematic review of the validity and evidence.

    Science.gov (United States)

    Faurholt-Jepsen, Maria; Munkholm, Klaus; Frost, Mads; Bardram, Jakob E; Kessing, Lars Vedel

    2016-01-15

    Various paper-based mood charting instruments are used in the monitoring of symptoms in bipolar disorder. During recent years an increasing number of electronic self-monitoring tools have been developed. The objectives of this systematic review were 1) to evaluate the validity of electronic self-monitoring tools as a method of evaluating mood compared to clinical rating scales for depression and mania and 2) to investigate the effect of electronic self-monitoring tools on clinically relevant outcomes in bipolar disorder. A systematic review of the scientific literature, reported according to the Preferred Reporting items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines was conducted. MEDLINE, Embase, PsycINFO and The Cochrane Library were searched and supplemented by hand search of reference lists. Databases were searched for 1) studies on electronic self-monitoring tools in patients with bipolar disorder reporting on validity of electronically self-reported mood ratings compared to clinical rating scales for depression and mania and 2) randomized controlled trials (RCT) evaluating electronic mood self-monitoring tools in patients with bipolar disorder. A total of 13 published articles were included. Seven articles were RCTs and six were longitudinal studies. Electronic self-monitoring of mood was considered valid compared to clinical rating scales for depression in six out of six studies, and in two out of seven studies compared to clinical rating scales for mania. The included RCTs primarily investigated the effect of heterogeneous electronically delivered interventions; none of the RCTs investigated the sole effect of electronic mood self-monitoring tools. Methodological issues with risk of bias at different levels limited the evidence in the majority of studies. Electronic self-monitoring of mood in depression appears to be a valid measure of mood in contrast to self-monitoring of mood in mania. There are yet few studies on the effect of electronic

  18. Validating an electronic health literacy scale in an older hispanic population.

    Science.gov (United States)

    Aponte, Judith; Nokes, Kathleen M

    2017-09-01

    To examine the validity of the Spanish version of an instrument used to measure electronic health literacy (eHEALS) with an older Hispanic population from a number of Spanish-language countries living in New York City in the United States (US). Although the Internet is available globally, complex skills are needed to use this source of valuable health-related information effectively. Electronic health literacy is a multifactorial concept that includes health literacy but also requires technology skills. Cross-sectional. Recruitment occurred at a Senior Organization located in a largely Hispanic neighbourhood in New York City (N = 100). Participants completed eHEALS and selected items from the Health Information National Trends Survey (HINTS) which assesses how adults use different communication channels, including the Internet, to obtain vital health information. Data from the US HINTS sample (N = 162) were matched to the Senior Organization sample on age range and Hispanic ethnicity. The average Senior Organization participant was 68 years old, female, born in one of six different Spanish-language countries, and completed high school while the average HINTS participant was 67 years old, female and had high school or less education. Although there was no relationship with the two HINTS subscales and electronic health literacy, there were significant relationships between electronic health literacy and health status and confidence in self-care. Inadequate electronic health literacy is a barrier to positive health outcomes. The Spanish version of eHEALS could be used as a screening instrument to identify gaps and tailored interventions could be developed to increase consumer confidence in using the Internet for reliable health-related information. Knowledge in self-management is related to positive health outcomes; all persons irrespective of their electronic health literacy should be able to use all sources of health information to enhance their self-care.

  19. Non-local electron transport validation using 2D DRACO simulations

    Science.gov (United States)

    Cao, Duc; Chenhall, Jeff; Moll, Eli; Prochaska, Alex; Moses, Gregory; Delettrez, Jacques; Collins, Tim

    2012-10-01

    Comparison of 2D DRACO simulations, using a modified versionfootnotetextprivate communications with M. Marinak and G. Zimmerman, LLNL. of the Schurtz, Nicolai and Busquet (SNB) algorithmfootnotetextSchurtz, Nicolai and Busquet, ``A nonlocal electron conduction model for multidimensional radiation hydrodynamics codes,'' Phys. Plasmas 7, 4238(2000). for non-local electron transport, with direct drive shock timing experimentsfootnotetextT. Boehly, et. al., ``Multiple spherically converging shock waves in liquid deuterium,'' Phys. Plasmas 18, 092706(2011). and with the Goncharov non-local modelfootnotetextV. Goncharov, et. al., ``Early stage of implosion in inertial confinement fusion: Shock timing and perturbation evolution,'' Phys. Plasmas 13, 012702(2006). in 1D LILAC will be presented. Addition of an improved SNB non-local electron transport algorithm in DRACO allows direct drive simulations with no need for an electron conduction flux limiter. Validation with shock timing experiments that mimic the laser pulse profile of direct drive ignition targets gives a higher confidence level in the predictive capability of the DRACO code. This research was supported by the University of Rochester Laboratory for Laser Energetics.

  20. New pediatric vision screener, part II: electronics, software, signal processing and validation.

    Science.gov (United States)

    Gramatikov, Boris I; Irsch, Kristina; Wu, Yi-Kai; Guyton, David L

    2016-02-04

    We have developed an improved pediatric vision screener (PVS) that can reliably detect central fixation, eye alignment and focus. The instrument identifies risk factors for amblyopia, namely eye misalignment and defocus. The device uses the birefringence of the human fovea (the most sensitive part of the retina). The optics have been reported in more detail previously. The present article focuses on the electronics and the analysis algorithms used. The objective of this study was to optimize the analog design, data acquisition, noise suppression techniques, the classification algorithms and the decision making thresholds, as well as to validate the performance of the research instrument on an initial group of young test subjects-18 patients with known vision abnormalities (eight male and 10 female), ages 4-25 (only one above 18) and 19 controls with proven lack of vision issues. Four statistical methods were used to derive decision making thresholds that would best separate patients with abnormalities from controls. Sensitivity and specificity were calculated for each method, and the most suitable one was selected. Both the central fixation and the focus detection criteria worked robustly and allowed reliable separation between normal test subjects and symptomatic subjects. The sensitivity of the instrument was 100 % for both central fixation and focus detection. The specificity was 100 % for central fixation and 89.5 % for focus detection. The overall sensitivity was 100 % and the overall specificity was 94.7 %. Despite the relatively small initial sample size, we believe that the PVS instrument design, the analysis methods employed, and the device as a whole, will prove valuable for mass screening of children.

  1. Electron impact study of potassium hydroxide

    International Nuclear Information System (INIS)

    Vuskovic, L.; Trajmar, S.

    1979-01-01

    An ''elastic'' scattering study for low impact energies (5--20 ev) is reported for electron impact excitation of KOH. The ''elastic'' scattering is regarded as the sum of elastic rotational and vibrational contributions to the scattering

  2. ClinicalCodes: an online clinical codes repository to improve the validity and reproducibility of research using electronic medical records.

    Science.gov (United States)

    Springate, David A; Kontopantelis, Evangelos; Ashcroft, Darren M; Olier, Ivan; Parisi, Rosa; Chamapiwa, Edmore; Reeves, David

    2014-01-01

    Lists of clinical codes are the foundation for research undertaken using electronic medical records (EMRs). If clinical code lists are not available, reviewers are unable to determine the validity of research, full study replication is impossible, researchers are unable to make effective comparisons between studies, and the construction of new code lists is subject to much duplication of effort. Despite this, the publication of clinical codes is rarely if ever a requirement for obtaining grants, validating protocols, or publishing research. In a representative sample of 450 EMR primary research articles indexed on PubMed, we found that only 19 (5.1%) were accompanied by a full set of published clinical codes and 32 (8.6%) stated that code lists were available on request. To help address these problems, we have built an online repository where researchers using EMRs can upload and download lists of clinical codes. The repository will enable clinical researchers to better validate EMR studies, build on previous code lists and compare disease definitions across studies. It will also assist health informaticians in replicating database studies, tracking changes in disease definitions or clinical coding practice through time and sharing clinical code information across platforms and data sources as research objects.

  3. NATO Advanced Study Institute on Electron Crystallography

    CERN Document Server

    Weirich, Thomas E; Zou, Xiaodong

    2006-01-01

    During the last decade we have been witness to several exciting achievements in electron crystallography. This includes structural and charge density studies on organic molecules complicated inorganic and metallic materials in the amorphous, nano-, meso- and quasi-crystalline state and also development of new software, tailor-made for the special needs of electron crystallography. Moreover, these developments have been accompanied by a now available new generation of computer controlled electron microscopes equipped with high-coherent field-emission sources, cryo-specimen holders, ultra-fast CCD cameras, imaging plates, energy filters and even correctors for electron optical distortions. Thus, a fast and semi-automatic data acquisition from small sample areas, similar to what we today know from imaging plates diffraction systems in X-ray crystallography, can be envisioned for the very near future. This progress clearly shows that the contribution of electron crystallography is quite unique, as it enables to r...

  4. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    Science.gov (United States)

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; Ppreferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  5. CFD Validation Studies for Hypersonic Flow Prediction

    Science.gov (United States)

    Gnoffo, Peter A.

    2001-01-01

    A series of experiments to measure pressure and heating for code validation involving hypersonic, laminar, separated flows was conducted at the Calspan-University at Buffalo Research Center (CUBRC) in the Large Energy National Shock (LENS) tunnel. The experimental data serves as a focus for a code validation session but are not available to the authors until the conclusion of this session. The first set of experiments considered here involve Mach 9.5 and Mach 11.3 N2 flow over a hollow cylinder-flare with 30 degree flare angle at several Reynolds numbers sustaining laminar, separated flow. Truncated and extended flare configurations are considered. The second set of experiments, at similar conditions, involves flow over a sharp, double cone with fore-cone angle of 25 degrees and aft-cone angle of 55 degrees. Both sets of experiments involve 30 degree compressions. Location of the separation point in the numerical simulation is extremely sensitive to the level of grid refinement in the numerical predictions. The numerical simulations also show a significant influence of Reynolds number on extent of separation. Flow unsteadiness was easily introduced into the double cone simulations using aggressive relaxation parameters that normally promote convergence.

  6. Validation of Using Fitness Center Attendance Electronic Records to Assess the Frequency of Moderate/Vigorous Leisure-Time Physical Activity among Adults

    Science.gov (United States)

    Amireault, Steve; Godin, Gaston

    2014-01-01

    The purpose of this study was to provide three construct validity evidence for using fitness center attendance electronic records to objectively assess the frequency of leisure-time physical activity among adults. One hundred members of a fitness center (45 women and 55 men; aged 18 to 64 years) completed a self-report leisure-time physical…

  7. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis.

    Science.gov (United States)

    de Vries, R; Brinkman, P; van der Schee, M P; Fens, N; Dijkers, E; Bootsma, S K; de Jongh, F H C; Sterk, P J

    2015-10-15

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We aimed to determine and optimize the technical performance and diagnostic accuracy of exhaled breath analysis linked to routine spirometry. Exhaled breath was collected in triplicate in healthy subjects by an eNose (SpiroNose) based on five identical metal oxide semiconductor sensor arrays (three arrays monitoring exhaled breath and two reference arrays monitoring ambient air) at the rear end of a pneumotachograph. First, the influence of flow, volume, humidity, temperature, environment, etc, was assessed. Secondly, a two-centre case-control study was performed using diagnostic and monitoring visits in day-to-day clinical care in patients with a (differential) diagnosis of asthma, chronic obstructive pulmonary disease (COPD) or lung cancer. Breathprint analysis involved signal processing, environment correction based on alveolar gradients and statistics based on principal component (PC) analysis, followed by discriminant analysis (Matlab2014/SPSS20). Expiratory flow showed a significant linear correlation with raw sensor deflections (R(2)  =  0.84) in 60 healthy subjects (age 43  ±  11 years). No correlation was found between sensor readings and exhaled volume, humidity and temperature. Exhaled data after environment correction were highly reproducible for each sensor array (Cohen's Kappa 0.81-0.94). Thirty-seven asthmatics (41  ±  14.2 years), 31 COPD patients (66  ±  8.4 years), 31 lung cancer patients (63  ±  10.8 years) and 45 healthy controls (41  ±  12.5 years) entered the cross-sectional study. SpiroNose could adequately distinguish between controls, asthma, COPD and lung cancer patients with cross-validation values

  8. Electronic implementation of a novel surveillance paradigm for ventilator-associated events. Feasibility and validation

    NARCIS (Netherlands)

    Klein Klouwenberg, Peter M. C.; van Mourik, Maaike S. M.; Ong, David S. Y.; Horn, Janneke; Schultz, Marcus J.; Cremer, Olaf L.; Bonten, Marc J. M.

    2014-01-01

    Accurate surveillance of ventilator-associated pneumonia (VAP) is hampered by subjective diagnostic criteria. A novel surveillance paradigm for ventilator-associated events (VAEs) was introduced. To determine the validity of surveillance using the new VAE algorithm. Prospective cohort study in two

  9. Study, development and validation of a dead-timeless electronic architecture concept for highly sensitive PET (Positron Emission Tomograph); Etude, developpement et validation d'un concept d'architecture electronique sans temps mort pour TEP de haute sensibilite

    Energy Technology Data Exchange (ETDEWEB)

    Vert, P.E

    2007-03-15

    Positron emission tomographs (PET) are fitted with highly capable reading electronics, which owns qualities and drawbacks. Highly accused at first as an explanation of the poor sensitivity of these imagers, the present study points out that the dead-times shared along the chains contribute to only 16 % in the data losses at a typical activity of 10 {mu}Ci/ml. The gross acquisition rates could thus be raised by 20 % through a suppression of these saturations. Looking in details at the philosophy of the acquisition procedure, a property appears to circumscribe the sensitivity even more: the timing resolution. The latter conditions, to the first order, the rejection capabilities of random events, part of the scattered ones and hence noise which is finally rated to the true coincidences the signal is made up of. Minimizing the resolving time goes through the suppression of the unneeded actors along with the adoption of a well adapted time-stamping method (optimal filtering). In doing so, the intrinsic channel resolution appears to be possibly lowered by a factor 7, reducing to 350 ps. The bottom value of the coincidence window may be narrowed as a consequence, leading to an increase of the NECR (noise equivalent count rate) by 50 per cent. At this stage, a time of flight (TOF) algorithms can be implemented. As an opportunist, it promises a reduction of the noise variance by 430 %, a gain that echoes on the NECR figure. Finally merging all these ideas allows to expect an improvement close to an order of magnitude on the NECR, with the hope of routine exams shortened by the same amount. In this context, it appeared logical to imagine a new electronics acquisition synoptic dedicated to fully pixelized PET. The number of channels blows up by the way when compared to the existing, this statement being partially balanced by the decision to fully integrate the electronics. The measures of the energy and time are planned to be performed with a single channel, with a continuous

  10. Using wound care algorithms: a content validation study.

    Science.gov (United States)

    Beitz, J M; van Rijswijk, L

    1999-09-01

    Valid and reliable heuristic devices facilitating optimal wound care are lacking. The objectives of this study were to establish content validation data for a set of wound care algorithms, to identify their associated strengths and weaknesses, and to gain insight into the wound care decision-making process. Forty-four registered nurse wound care experts were surveyed and interviewed at national and regional educational meetings. Using a cross-sectional study design and an 83-item, 4-point Likert-type scale, this purposive sample was asked to quantify the degree of validity of the algorithms' decisions and components. Participants' comments were tape-recorded, transcribed, and themes were derived. On a scale of 1 to 4, the mean score of the entire instrument was 3.47 (SD +/- 0.87), the instrument's Content Validity Index was 0.86, and the individual Content Validity Index of 34 of 44 participants was > 0.8. Item scores were lower for those related to packing deep wounds (P valid and reliable definitions. The wound care algorithms studied proved valid. However, the lack of valid and reliable wound assessment and care definitions hinders optimal use of these instruments. Further research documenting their clinical use is warranted. Research-based practice recommendations should direct the development of future valid and reliable algorithms designed to help nurses provide optimal wound care.

  11. Dissociative electron attachment studies on acetone

    International Nuclear Information System (INIS)

    Prabhudesai, Vaibhav S.; Tadsare, Vishvesh; Ghosh, Sanat; Gope, Krishnendu; Davis, Daly; Krishnakumar, E.

    2014-01-01

    Dissociative electron attachment (DEA) to acetone is studied in terms of the absolute cross section for various fragment channels in the electron energy range of 0–20 eV. H − is found to be the most dominant fragment followed by O − and OH − with only one resonance peak between 8 and 9 eV. The DEA dynamics is studied by measuring the angular distribution and kinetic energy distribution of fragment anions using Velocity Slice Imaging technique. The kinetic energy and angular distribution of H − and O − fragments suggest a many body break-up for the lone resonance observed. The ab initio calculations show that electron is captured in the multi-centered anti-bonding molecular orbital which would lead to a many body break-up of the resonance

  12. Dissociative electron attachment studies on acetone

    Energy Technology Data Exchange (ETDEWEB)

    Prabhudesai, Vaibhav S., E-mail: vaibhav@tifr.res.in; Tadsare, Vishvesh; Ghosh, Sanat; Gope, Krishnendu; Davis, Daly; Krishnakumar, E. [Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2014-10-28

    Dissociative electron attachment (DEA) to acetone is studied in terms of the absolute cross section for various fragment channels in the electron energy range of 0–20 eV. H{sup −} is found to be the most dominant fragment followed by O{sup −} and OH{sup −} with only one resonance peak between 8 and 9 eV. The DEA dynamics is studied by measuring the angular distribution and kinetic energy distribution of fragment anions using Velocity Slice Imaging technique. The kinetic energy and angular distribution of H{sup −} and O{sup −} fragments suggest a many body break-up for the lone resonance observed. The ab initio calculations show that electron is captured in the multi-centered anti-bonding molecular orbital which would lead to a many body break-up of the resonance.

  13. ZnO sublimation using a polyenergetic pulsed electron beam source: numerical simulation and validation

    Energy Technology Data Exchange (ETDEWEB)

    Tricot, S; Semmar, N; Lebbah, L; Boulmer-Leborgne, C, E-mail: sylvain.tricot@univ-orleans.f [GREMI, UMR 6606-CNRS/Universite d' Orleans, 14 rue d' Issoudun, BP 6744, 45067 Orleans cedex 2 (France)

    2010-02-17

    This paper details the electro-thermal study of the sublimation phase on a zinc oxide surface. This thermodynamic process occurs when a ZnO target is bombarded by a pulsed electron beam source composed of polyenergetic electrons. The source delivers short pulses of 180 ns of electrons with energies up to 16 keV. The beam total current reaches 800 A and is focused onto a spot area 2 mm in diameter. The Monte Carlo CASINO program is used to study the first stage of the interaction and to define the heat source space distribution inside the ZnO target. Simulation of the second stage of interaction is developed in a COMSOL multiphysics project. The simulated thermal field induced by space and time heat conduction is presented. Typically for a pulsed electron beam 2 mm in diameter of electrons having energies up to 16 keV, the surface temperature reaches a maximum of 7000 K. The calculations are supported by SEM pictures of the target irradiated by various beam energies and numbers of pulses.

  14. ZnO sublimation using a polyenergetic pulsed electron beam source: numerical simulation and validation

    International Nuclear Information System (INIS)

    Tricot, S; Semmar, N; Lebbah, L; Boulmer-Leborgne, C

    2010-01-01

    This paper details the electro-thermal study of the sublimation phase on a zinc oxide surface. This thermodynamic process occurs when a ZnO target is bombarded by a pulsed electron beam source composed of polyenergetic electrons. The source delivers short pulses of 180 ns of electrons with energies up to 16 keV. The beam total current reaches 800 A and is focused onto a spot area 2 mm in diameter. The Monte Carlo CASINO program is used to study the first stage of the interaction and to define the heat source space distribution inside the ZnO target. Simulation of the second stage of interaction is developed in a COMSOL multiphysics project. The simulated thermal field induced by space and time heat conduction is presented. Typically for a pulsed electron beam 2 mm in diameter of electrons having energies up to 16 keV, the surface temperature reaches a maximum of 7000 K. The calculations are supported by SEM pictures of the target irradiated by various beam energies and numbers of pulses.

  15. Validity of the independent-processes approximation for resonance structures in electron-ion scattering cross sections

    International Nuclear Information System (INIS)

    Badnell, N.R.; Pindzola, M.S.; Griffin, D.C.

    1991-01-01

    The total inelastic cross section for electron-ion scattering may be found in the independent-processes approximation by adding the resonant cross section to the nonresonant background cross section. We study the validity of this approximation for electron excitation of multiply charged ions. The resonant-excitation cross section is calculated independently using distorted waves for various Li-like and Na-like ions using (N+1)-electron atomic-structure methods previously developed for the calculation of dielectronic-recombination cross sections. To check the effects of interference between the two scattering processes, we also carry out detailed close-coupling calculations for the same atomic ions using the R-matrix method. For low ionization stages, interference effects manifest themselves sometimes as strong window features in the close-coupling cross section, which are not present in the independent-processes cross section. For higher ionization stages, however, the resonance features found in the independent-processes approximation are found to be in good agreement with the close-coupling results

  16. Study of Scanning Tunneling Microscope control electronics

    International Nuclear Information System (INIS)

    Oliva, A.J.; Pancarobo, M.; Denisenko, N.; Aguilar, M.; Rejon, V.; Pena, J.L.

    1994-01-01

    A theoretical study of Scanning Tunneling Microscope control electronics is made. The knowledge of its behaviour allows us to determine accurately the region where the unstable operation could effect the measurements, and also to set the optimal working parameters. Each feedback circuitry compound is discussed as well as their mutual interaction. Different working conditions analysis and results are presented. (Author) 12 refs

  17. Runaway-electron-materials interaction studies

    International Nuclear Information System (INIS)

    Bolt, H.; Miyahara, A.

    1990-03-01

    During the operation of magnetic fusion devices it has been frequently observed that runaway electrons can cause severe damage to plasma facing components. The energy of the runaway electrons could possibly reach several 100 MeV in a next generation device with an energy content in the plasma in the order of 100 MJ. In this study effects of high energy electron - materials interaction were determined by laboratory experiments using particle beam facilities, i.e. the Electron Linear Accelerator of the Institute of Scientific and Industrial Research of Osaka University and the 10 MW Neutral Beam Injection Test Stand of the National Institute for Fusion Science. The experiments and further analyses lead to a first assessment of the damage thresholds of plasma facing materials and components under runaway electron impact. It was found that metals (stainless steel, molybdenum, tungsten) showed grain growth, crack formation and/or melting already below the threshold for crack initiation on graphite (14-33 MJ/m 2 ). Strong erosion of carbon materials would occur above 100 MJ/m 2 . Damage to metal coolant channels can occur already below an energy deposition of 100 MJ/m 2 . The energy deposited in the metal coolant channels depends on the thickness of the plasma facing carbon material D, with the shielding efficiency S of carbon approximately as S∼D 1.15 . (author) 304 refs. 12 tabs. 59 figs

  18. Electron cloud buildup studies for the LHC

    CERN Document Server

    AUTHOR|(CDS)2160803; Boine-Frankenheim, Oliver

    Electron clouds can develop in accelerators operating with positively charged particles. The con- sequences of e-cloud related effects are very important for the operation of the Large Hadron Collider (LHC) at CERN, and for the design of future accelerators including the LHC luminosity upgrade (HL-LHC). High electron densities are generated by an interaction between the beam and the confining chamber. Primary electrons, that can be generated through various mecha- nisms, are accelerated by the beam and impinge on the chamber walls, thereby extracting more electrons from the material. Furthermore they also deposit their kinetic energy in the process, which has to be compensated by the cooling system. Especially in cryogenic environments, as it is the case for a large part of the LHC, high heat loads can pose a serious problem. In order to improve the understanding of the electron cloud, simulation studies are performed with the code PyECLOUD, developed at CERN. The work of the first half of the project is desc...

  19. Penning ionization processes studied by electron spectroscopy

    International Nuclear Information System (INIS)

    Yencha, A.J.

    1978-01-01

    The technique of measuring the kinetic energy of electrons ejected from atomic or molecular species as a result of collisional energy transfer between a metastable excited rare gas atom and an atom or molecule is known as Penning ionization spectroscopy. Like the analogous photoionization process of photoelectron spectroscopy, a considerable amount of information has been gained about the ionization potentials of numerous molecular systems. It is, in fact, through the combined analyses of photoelectron and Penning electron spectra that affords a probe of the particle-particle interactions that occur in the Penning process. In this paper a short survey of the phenomenon of Penning ionization, as studied by electron spectroscopy, will be presented as it pertains to the ionization processes of simple molecules by metastable excited atoms. (author)

  20. Electronic self-monitoring of mood using IT platforms in adult patients with bipolar disorder: A systematic review of the validity and evidence

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Munkholm, Klaus; Frost, Mads

    2016-01-01

    -monitoring is limited by methodological issues and by a lack of RCTs. Although the idea of electronic self-monitoring of mood seems appealing, studies using rigorous methodology investigating the beneficial as well as possible harmful effects of electronic self-monitoring are needed.......Background: Various paper-based mood charting instruments are used in the monitoring of symptoms in bipolar disorder. During recent years an increasing number of electronic self-monitoring tools have been developed. The objectives of this systematic review were 1) to evaluate the validity...... of electronic self-monitoring tools as a method of evaluating mood compared to clinical rating scales for depression and mania and 2) to investigate the effect of electronic self-monitoring tools on clinically relevant outcomes in bipolar disorder. Methods: A systematic review of the scientific literature...

  1. Simulation Based Studies in Software Engineering: A Matter of Validity

    Directory of Open Access Journals (Sweden)

    Breno Bernard Nicolau de França

    2015-04-01

    Full Text Available Despite the possible lack of validity when compared with other science areas, Simulation-Based Studies (SBS in Software Engineering (SE have supported the achievement of some results in the field. However, as it happens with any other sort of experimental study, it is important to identify and deal with threats to validity aiming at increasing their strength and reinforcing results confidence. OBJECTIVE: To identify potential threats to SBS validity in SE and suggest ways to mitigate them. METHOD: To apply qualitative analysis in a dataset resulted from the aggregation of data from a quasi-systematic literature review combined with ad-hoc surveyed information regarding other science areas. RESULTS: The analysis of data extracted from 15 technical papers allowed the identification and classification of 28 different threats to validity concerned with SBS in SE according Cook and Campbell’s categories. Besides, 12 verification and validation procedures applicable to SBS were also analyzed and organized due to their ability to detect these threats to validity. These results were used to make available an improved set of guidelines regarding the planning and reporting of SBS in SE. CONCLUSIONS: Simulation based studies add different threats to validity when compared with traditional studies. They are not well observed and therefore, it is not easy to identify and mitigate all of them without explicit guidance, as the one depicted in this paper.

  2. School Alienation: A Construct Validation Study

    Science.gov (United States)

    Morinaj, Julia; Scharf, Jan; Grecu, Alyssa; Hadjar, Andreas; Hascher, Tina; Marcin, Kaja

    2017-01-01

    Early identification of school alienation is of great importance for students' educational outcomes and successful participation in society. This study examined the psychometric characteristics of a newly developed assessment instrument, the School Alienation Scale (SALS), to measure school alienation among primary and secondary school students.…

  3. 29 CFR 1607.5 - General standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ...) (hereinafter “A.P.A. Standards”) and standard textbooks and journals in the field of personnel selection. D... market and the job should be considered in the determination of when a validity study is outdated. ...

  4. GPM GROUND VALIDATION GCPEX SNOW MICROPHYSICS CASE STUDY V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation GCPEX Snow Microphysics Case Study characterizes the 3-D microphysical evolution and distribution of snow in context of the thermodynamic...

  5. Positron lifetime studies of electron irradiated copper

    International Nuclear Information System (INIS)

    Hadnagy, T.D.

    1976-01-01

    Single-crystal copper was irradiated with 4.5-MeV electrons producing simple Frenkel defects as well as a significant concentration of divacancies. Mean positron lifetime characteristics, which are sensitive to the presence of vacancies and multivacancies in copper, was monitored after isochronal anneals between 80 and 800 0 K to determine the relative change of characteristic mean lifetimes and their associated intensities. Also a study of the dependence of the mean positron lifetime on the total electron fluence was made and compared with existing theories relating these lifetimes to vacancy or multivacancy concentrations. Numerical data from curve fitting procedures using a conventional trapping model for defect-induced changes in positron lifetimes indicate that upon irradiation with 4.5-MeV electrons at 80 0 K, about 8 percent of the defects produced are divacancy units. Divacancy units appear to be several times more effective in trapping positrons than are monovacancies. Further, the experimental data suggest that the stage III annealing processes in electron-irradiated copper most probably involve the motion and removal of both monovacancies and divacancies. A conglomerate (multivacancy) unit appears to exist as a stable entity even after annealing procedures are carried out at temperatures slightly above the stage III region. Such a stable unit could serve as a nucleation center for the appearance of voids

  6. Development and validation of an ex vivo electron paramagnetic resonance fingernail bio-dosimetric method

    International Nuclear Information System (INIS)

    He, Xiaoming; Swarts, Steven G.; Marsh, Stephen D.; Demidenko, Eugene; Flood, Ann B.; Grinberg, Oleg; Gui, Jiang; Mariani, Michael; Ruuge, Andres E.; Tipikin, Dmitry; Swartz, Harold M.; Sidabras, Jason W.; Wilcox, Dean E.

    2014-01-01

    from 15 donors was used to validate the sample handling and spectral analysis methods that have been developed but without the interference of a native background signal. Good consistency has been obtained between the actual RIS and the estimated RIS computed from spectral analysis. In addition to the success in RIS estimation, a linear dose response has also been achieved for all individuals in this study, where the radiation dose ranges from 0 to 6 Gy. A second 16-donor nail set with 96 nail samples was used to test the spectral fitting model where the background signal was included during the fitting of the clipped nail spectra data. Although the dose response for the estimated and actual RIS calculated in both donor nail sets was similar, there was an increased variability in the RIS values that was likely due to the variability in the background signal between donors. Although the current methods of sample handling and spectral analysis show good potential for estimating the RIS in the EPR spectra of nail clippings, there is a remaining degree of variability in the RIS estimate that needs to be addressed; this should be achieved by identifying and accounting for demographic sources of variability in the background nail signal and the composition of the nail matrix. (authors)

  7. NATO Advanced Study Institute on Superconducting Electronics

    CERN Document Server

    Nisenhoff, Martin; Superconducting Electronics

    1989-01-01

    The genesis of the NATO Advanced Study Institute (ASI) upon which this volume is based, occurred during the summer of 1986 when we came to the realization that there had been significant progress during the early 1980's in the field of superconducting electronics and in applications of this technology. Despite this progress, there was a perception among many engineers and scientists that, with the possible exception of a limited number of esoteric fundamental studies and applications (e.g., the Josephson voltage standard or the SQUID magnetometer), there was no significant future for electronic systems incorporating superconducting elements. One of the major reasons for this perception was the aversion to handling liquid helium or including a closed-cycle helium liquefier. In addition, many critics felt that IBM's cancellation of its superconducting computer project in 1983 was "proof" that superconductors could not possibly compete with semiconductors in high-speed signal processing. From our persp...

  8. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  9. Test of Creative Imagination: Validity and Reliability Study

    Science.gov (United States)

    Gundogan, Aysun; Ari, Meziyet; Gonen, Mubeccel

    2013-01-01

    The purpose of this study was to investigate validity and reliability of the test of creative imagination. This study was conducted with the participation of 1000 children, aged between 9-14 and were studying in six primary schools in the city center of Denizli Province, chosen by cluster ratio sampling. In the study, it was revealed that the…

  10. Studying the electronic customer relationship management and its ...

    African Journals Online (AJOL)

    Studying the electronic customer relationship management and its effect on bank quality outcomes. ... Journal of Fundamental and Applied Sciences ... Keywords: Electronic Banking, Service Quality, Customer Satisfaction, Management of

  11. Generation and study of relativistic electron beam

    International Nuclear Information System (INIS)

    Iyyengar, S.K.; Ron, P.H.; Mittal, K.C.; Goel, A.K.; Ramaswamy, V.; Rohatgi, V.K.

    1977-01-01

    Pulsed Electron Beam (REB) technology has progressed rapidly in recent years because of applications in various fields like radiation sources, high power laser development, plasma heating and fusion research. The REB development programme at the Plasma Physics Section of Bhabha Atomic Research Centre, Bombay, has been described. The design features of the 375 KV, 3500 A, 75 Joule REB generator are discussed. The diagnostic equipment developed for the studies is described. The present experimental studies and some preliminary results on beam characterisation are presented. (author)

  12. The validity of the 4-Skills Scan: A double validation study.

    Science.gov (United States)

    van Kernebeek, W G; de Kroon, M L A; Savelsbergh, G J P; Toussaint, H M

    2018-06-01

    Adequate gross motor skills are an essential aspect of a child's healthy development. Where physical education (PE) is part of the primary school curriculum, a strong curriculum-based emphasis on evaluation and support of motor skill development in PE is apparent. Monitoring motor development is then a task for the PE teacher. In order to fulfil this task, teachers need adequate tools. The 4-Skills Scan is a quick and easily manageable gross motor skill instrument; however, its validity has never been assessed. Therefore, the purpose of this study is to assess the construct and concurrent validity of both 4-Skills Scans (version 2007 and version 2015). A total of 212 primary school children (6 - 12 years old), was requested to participate in both versions of the 4-Skills Scan. For assessing construct validity, children covered an obstacle course with video recordings for observation by an expert panel. For concurrent validity, a comparison was made with the MABC-2, by calculating Pearson correlations. Multivariable linear regression analyses were performed to determine the contribution of each subscale to the construct of gross motor skills, according to the MABC-2 and the expert panel. Correlations between the 4-Skills Scans and expert valuations were moderate, with coefficients of .47 (version 2007) and .46 (version 2015). Correlations between the 4-Skills Scans and the MABC-2 (gross) were moderate (.56) for version 2007 and high (.64) for version 2015. It is concluded that both versions of the 4-Skills Scans are satisfactory valid instruments for assessing gross motor skills during PE lessons. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Monte Carlo study of electron relaxation in graphene with spin polarized, degenerate electron gas in presence of electron-electron scattering

    Science.gov (United States)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-12-01

    The Monte Carlo simulation method is applied to study the relaxation of excited electrons in monolayer graphene. The presence of spin polarized background electrons population, with density corresponding to highly degenerate conditions is assumed. Formulas of electron-electron scattering rates, which properly account for electrons presence in two energetically degenerate, inequivalent valleys in this material are presented. The electron relaxation process can be divided into two phases: thermalization and cooling, which can be clearly distinguished when examining the standard deviation of electron energy distribution. The influence of the exchange effect in interactions between electrons with parallel spins is shown to be important only in transient conditions, especially during the thermalization phase.

  14. The Jackson Career Explorer: Two Further Validity Studies

    Science.gov (United States)

    Schermer, Julie Aitken

    2012-01-01

    The present report consists of two further validity studies using the Jackson Career Explorer (JCE), a short form and continuous version of the Jackson Vocational Interest Survey, measuring 34 interests. The first study examined the relationships between the JCE and five personality factors, from a sample of 528 individuals. The correlations found…

  15. Basic School Skills Inventory-3: Validity and Reliability Study

    Science.gov (United States)

    Yildiz, F. Ülkü; Çagdas, Aysel; Kayili, Gökhan

    2017-01-01

    The purpose of this study is to perform the validity-reliability analysis of the three subtests of Basic School Skills Inventory 3--Mathematics, Classroom Behavior and Daily Life skills--and do its adaptation for four to six year-old Turkish children. The sample of the study included 595 four to six year-old Turkish children attending public and…

  16. A Validation Study of the Adolescent Dissociative Experiences Scale

    Science.gov (United States)

    Keck Seeley, Susan. M.; Perosa, Sandra, L.; Perosa, Linda, M.

    2004-01-01

    Objective: The purpose of this study was to further the validation process of the Adolescent Dissociative Experiences Scale (A-DES). In this study, a 6-item Likert response format with descriptors was used when responding to the A-DES rather than the 11-item response format used in the original A-DES. Method: The internal reliability and construct…

  17. California Diploma Project Technical Report III: Validity Study--Validity Study of the Health Sciences and Medical Technology Standards

    Science.gov (United States)

    McGaughy, Charis; Bryck, Rick; de Gonzalez, Alicia

    2012-01-01

    This study is a validity study of the recently revised version of the Health Science Standards. The purpose of this study is to understand how the Health Science Standards relate to college and career readiness, as represented by survey ratings submitted by entry-level college instructors of health science courses and industry representatives. For…

  18. Cooperative learning benefits scale: construction and validation studies

    Directory of Open Access Journals (Sweden)

    José Lopes

    2014-07-01

    Full Text Available The aim of this study was to develop and validate a scale of benefits of the Cooperative Learning (SBCL given the exiguity of instruments that evaluate these outputs of the method. The study resorted to a convenience sample comprised of 162 students, males and females, aged between 11 and 18 years. The final instrument has 23 items in a two-dimensional factor structure: psychological and academic benefits and social benefits. The results indicate that the SBCL present good psychometric properties (construct and discriminant validity and reliability. The results are discussed in light of the model of cooperative learning.

  19. Discomfort Intolerance Scale: A Study of Reliability and Validity

    Directory of Open Access Journals (Sweden)

    Kadir ÖZDEL

    2012-03-01

    Full Text Available Objective: Discomfort Intolerance Scale was developed by Norman B. Schmidt et al. to assess the individual differences of capacity to withstand physical perturbations or uncomfortable bodily states (2006. The aim of this study is to investigate the validity and reliability of Discomfort Intolerance Scale-Turkish Version (RDÖ. Method: From two different universities, total of 225 students (male=167, female=58 were participated in this study. In order to determine the criterion validity, Beck Anxiety Inventory (BAI and State-Trait Anxiety Inventory (STAI were used. Construct validity was evaluated by factor analysis after the Kaiser-Meyer-Olkin (KMO and Barlett test had been performed. To assess the test-retest reliability the scale was re-applied to 54 participants 6 weeks later. Results: To assess construct validity of DIS, factor analyses were performed using varimax principal components analysis with varimax rotation. The factor analysis resulted in two factors named “discomfort (in tolerance” and “discomfort avoidance”. The Cronbach’s alpha coefficient for the entire scale, discomfort-(intolerance subscale, discomfortavoidance subscale were, .592, .670, .600 respectively. Correlations between two factors of DIS, discomfort intolerance and discomfort avoidance, and Trait Anxiety Inventory of STAI (State-Trait Anxiety Inventory were statistically significant at the level of 0.05. Test-retest reliability was statistically significant at the level of 0.01. Conclusion: Analysis demonstrated that DIS had a satisfactory level of reliability and validity in Turkish university students.

  20. Limitations in accurate electron density studies

    International Nuclear Information System (INIS)

    Wal, R. van der.

    1982-01-01

    Most of X-ray diffraction studies are devoted to the determination of three-dimensional crystal structures from the electron density distributions. In these cases the density distributions are described by the independent atom model (IAM model), which consists of a superposition of spherically averaged free atom densities, which are smeared by thermal vibrations. During the last few decades studies have been made into the deviations of the density distribution from the IAM model, which enables a study of the chemical binding between atoms. The total density can be described using pseudo-atom multipole models as a superposition of aspherical pseudo-atom densities. A fundamental problem is that the separation of this density into an IAM and a deformation part is not unique. This thesis considers the problem and besides deformation densities from X-ray diffraction also considers the corresponding deformation electric field and deformation potential. (C.F.)

  1. Auger electron spectroscopy studies of boron carbide

    International Nuclear Information System (INIS)

    Madden, H.H.; Nelson, G.C.; Wallace, W.O.

    1986-01-01

    Auger electron spectroscopy has been used to probe the electronic structure of ion bombardment (IB) cleaned surfaces of B 9 C and B 4 C samples. The shapes of the B-KVV and C-KVV Auger lines were found to be relatively insensitive to the bulk stoichiometry of the samples. This indicates that the local chemical environments surrounding B and C atoms, respectively, on the surfaces of the IB cleaned samples do not change appreciably in going from B 9 C to B 4 C. Fracturing the sample in situ is a way of producing a clean representative internal surface to compare with the IB surfaces. Microbeam techniques have been used to study a fracture surface of the B 9 C material with greater spatial resolution than in our studies of IB surfaces. The B 9 C fracture surface was not homogeneous and contained both C-rich and B-rich regions. The C-KVV line for the C-rich regions was graphitic in shape. Much of the C-rich regions was found by IB to be less than 100 nm in thickness. The C-KVV line from the B-rich regions was carbidic and did not differ appreciably in shape from those recorded for the IB cleaned surfaces

  2. External Validity of Electronic Sniffers for Automated Recognition of Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    McKown, Andrew C; Brown, Ryan M; Ware, Lorraine B; Wanderer, Jonathan P

    2017-01-01

    Automated electronic sniffers may be useful for early detection of acute respiratory distress syndrome (ARDS) for institution of treatment or clinical trial screening. In a prospective cohort of 2929 critically ill patients, we retrospectively applied published sniffer algorithms for automated detection of acute lung injury to assess their utility in diagnosis of ARDS in the first 4 ICU days. Radiographic full-text reports were searched for "edema" OR ("bilateral" AND "infiltrate") and a more detailed algorithm for descriptions consistent with ARDS. Patients were flagged as possible ARDS if a radiograph met search criteria and had a PaO 2 /FiO 2 or SpO 2 /FiO 2 of 300 or 315, respectively. Test characteristics of the electronic sniffers and clinical suspicion of ARDS were compared to a gold standard of 2-physician adjudicated ARDS. Thirty percent of 2841 patients included in the analysis had gold standard diagnosis of ARDS. The simpler algorithm had sensitivity for ARDS of 78.9%, specificity of 52%, positive predictive value (PPV) of 41%, and negative predictive value (NPV) of 85.3% over the 4-day study period. The more detailed algorithm had sensitivity of 88.2%, specificity of 55.4%, PPV of 45.6%, and NPV of 91.7%. Both algorithms were more sensitive but less specific than clinician suspicion, which had sensitivity of 40.7%, specificity of 94.8%, PPV of 78.2%, and NPV of 77.7%. Published electronic sniffer algorithms for ARDS may be useful automated screening tools for ARDS and improve on clinical recognition, but they are limited to screening rather than diagnosis because their specificity is poor.

  3. Electronic transport study in PAMAM dendrimers

    International Nuclear Information System (INIS)

    Vieira, Nirton C.S.; Soares, Demetrio A.W.; Fernandes, Edson G.R.; Queiroz, Alvaro A.A. de

    2005-01-01

    Dendrimers are nanomaterials that have many potential applications in medicine, including diagnosis and therapeutic procedures. Dendrimers are isomolecular polymers, with a very well controlled architecture and a thousand times smaller than cells. Dendrimers containing biocatalysts are of great interest for clinical applications in biosensors because of the way in which their chemical and electric conduction mechanism can be tailored. In this work, the polyamidoamine dendrimer (PAMAM) of generation 4 was synthesized by divergent route and characterized by NMR spectroscopy. The electronic transport properties of PAMAM in a metal-polymer type heterojunction were studied. The electrical conduction mechanism of PAMAM studied in the temperature range of 291-323 K indicates a conduction mechanism thermally activated. (author)

  4. Development and validation of stability indicating studies of ...

    African Journals Online (AJOL)

    Development and validation of stability indicating studies of paliperidone ... A simple and sensitive stability indicating HPLC method is developed for the ... The developed method was proved adequate for quantitative determination of ... Browse By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  5. Teachers' Engagement at Work: An International Validation Study

    Science.gov (United States)

    Klassen, Robert M.; Aldhafri, Said; Mansfield, Caroline F.; Purwanto, Edy; Siu, Angela F. Y.; Wong, Marina W.; Woods-McConney, Amanda

    2012-01-01

    This study explored the validity of the Utrecht Work Engagement Scale in a sample of 853 practicing teachers from Australia, Canada, China (Hong Kong), Indonesia, and Oman. The authors used multigroup confirmatory factor analysis to test the factor structure and measurement invariance across settings, after which they examined the relationships…

  6. 29 CFR 1607.14 - Technical standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ..., if the behavior results in work product(s), an analysis of the work product(s). Any job analysis.... This job analysis should show the work behavior(s) required for successful performance of the job, or... 29 Labor 4 2010-07-01 2010-07-01 false Technical standards for validity studies. 1607.14 Section...

  7. Validation Study of the Abbreviated Math Anxiety Scale: Spanish Adaptation

    Science.gov (United States)

    Brown, Jennifer L.; Sifuentes, Lucía Macías

    2016-01-01

    With growing numbers of Hispanic students enrolling in post-secondary school, there is a need to increase retention and graduation rates. The purpose of this study was to validate the Spanish adaptation of the Abbreviated Math Anxiety Scale (AMAS). The AMAS was translated and administered to 804 freshman students at a post-secondary institution in…

  8. A Validation Study of Maslow's Hierarchy of Needs Theory.

    Science.gov (United States)

    Clay, Rex J.

    A study was conducted to expand the body of research that tests the validity of Abraham Maslow's hierarchy of needs theory in a work context where it often serves as a guide for the supervisor's relationships with his subordinates. Data was gathered by questionnaire which tested for a hierarchy of needs among instructors at four community colleges…

  9. A validation study of the Brief Irrational Thoughts Inventory

    NARCIS (Netherlands)

    Hoogsteder, L.M.; Wissink, I.B.; Stams, G.J.J.M.; van Horn, J.E.; Hendriks, J.

    2014-01-01

    This study examines the reliability and validity of the "Brief Irrational Thoughts Inventory" (BITI) in a sample of 256 justice-involved youths. The BITI is a questionnaire used to determine the nature and severity of irrational thoughts related to aggressive (externalizing), sub-assertive

  10. Model validation studies of solar systems, Phase III. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Lantz, L.J.; Winn, C.B.

    1978-12-01

    Results obtained from a validation study of the TRNSYS, SIMSHAC, and SOLCOST solar system simulation and design are presented. Also included are comparisons between the FCHART and SOLCOST solar system design programs and some changes that were made to the SOLCOST program. Finally, results obtained from the analysis of several solar radiation models are presented. Separate abstracts were prepared for ten papers.

  11. A Validity Study of the Self-Esteem Inventory.

    Science.gov (United States)

    Landis, H. John

    Results of this validation study of a slightly modified version of the Coppersmith Self-Esteem Inventory substantiate its use with seventh graders to assess Goal I (concerning self-understanding and appreciation of self-worth) of the Educational Quality Assessment Program in Pennsylvania. Appendixes include the definition and rationale for Goal I,…

  12. Turkish Metalinguistic Awareness Scale: A Validity and Reliability Study

    Science.gov (United States)

    Varisoglu, Behice

    2018-01-01

    The aim of this study is to develop a useful, valid and reliable measurement tool that will help teacher candidates determine their Turkish metalinguistic awareness. During the development of the scale, a pool of items was created by scanning the relevant literature and examining other awareness scales. The materials prepared were re-examined…

  13. A Validation Study of the Student Oral Proficiency Assessment (SOPA).

    Science.gov (United States)

    Thompson, Lynn E.; Kenyon, Dorry M.; Rhodes, Nancy C.

    This study validated the Student Oral Proficiency Assessment (SOPA), an oral proficiency instrument designed for students in elementary foreign language programs. Elementary students who were tested with the SOPA were also administered other instruments designed to measure proficiency. These instruments included the Stanford Foreign Language Oral…

  14. Assessing validity of observational intervention studies - the Benchmarking Controlled Trials.

    Science.gov (United States)

    Malmivaara, Antti

    2016-09-01

    Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. To create and pilot test a checklist for appraising methodological validity of a BCT. The checklist was created by extracting the most essential elements from the comprehensive set of criteria in the previous paper on BCTs. Also checklists and scientific papers on observational studies and respective systematic reviews were utilized. Ten BCTs published in the Lancet and in the New England Journal of Medicine were used to assess feasibility of the created checklist. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. However, the piloted checklist should be validated in further studies. Key messages Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. This paper presents a checklist for appraising methodological validity of BCTs and pilot-tests the checklist with ten BCTs published in leading medical journals. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies.

  15. Reliability and validity of the foot and ankle outcome score: a validation study from Iran.

    Science.gov (United States)

    Negahban, Hossein; Mazaheri, Masood; Salavati, Mahyar; Sohani, Soheil Mansour; Askari, Marjan; Fanian, Hossein; Parnianpour, Mohamad

    2010-05-01

    The aims of this study were to culturally adapt and validate the Persian version of Foot and Ankle Outcome Score (FAOS) and present data on its psychometric properties for patients with different foot and ankle problems. The Persian version of FAOS was developed after a standard forward-backward translation and cultural adaptation process. The sample included 93 patients with foot and ankle disorders who were asked to complete two questionnaires: FAOS and Short-Form 36 Health Survey (SF-36). To determine test-retest reliability, 60 randomly chosen patients completed the FAOS again 2 to 6 days after the first administration. Test-retest reliability and internal consistency were assessed using intraclass correlation coefficient (ICC) and Cronbach's alpha, respectively. To evaluate convergent and divergent validity of FAOS compared to similar and dissimilar concepts of SF-36, the Spearman's rank correlation was used. Dimensionality was determined by assessing item-subscale correlation corrected for overlap. The results of test-retest reliability show that all the FAOS subscales have a very high ICC, ranging from 0.92 to 0.96. The minimum Cronbach's alpha level of 0.70 was exceeded by most subscales. The Spearman's correlation coefficient for convergent construct validity fell within 0.32 to 0.58 for the main hypotheses presented a priori between FAOS and SF-36 subscales. For dimensionality, the minimum Spearman's correlation coefficient of 0.40 was exceeded by most items. In conclusion, the results of our study show that the Persian version of FAOS seems to be suitable for Iranian patients with various foot and ankle problems especially lateral ankle sprain. Future studies are needed to establish stronger psychometric properties for patients with different foot and ankle problems.

  16. Development and validation study of the Smartphone Overuse Screening Questionnaire.

    Science.gov (United States)

    Lee, Han-Kyeong; Kim, Ji-Hae; Fava, Maurizio; Mischoulon, David; Park, Jae-Hyun; Shim, Eun-Jung; Lee, Eun-Ho; Lee, Ji Hyeon; Jeon, Hong Jin

    2017-11-01

    The aim of this study was to develop a screening questionnaire that could distinguish individuals at high risk of smartphone overuse from casual users. The reliability, validity, and diagnostic ability of the Smartphone Overuse Screening Questionnaire (SOS-Q) were evaluated. Preliminary items were assessed by 50 addiction experts on-line, and 28 questions were selected. A total of 158 subjects recruited from six community centers for internet addiction participated in this study. The SOS-Q, Young's internet addiction scale, Korean scale for internet addiction, and Smartphone Scale for Smartphone Addiction (S-Scale) were used to assess the concurrent validity. Construct validity was supported by a six-factor model using an exploratory factor analysis. The internal consistency and the item-total correlations were favorable (α = 0.95, r = 0.35-0.81). The test-retest reliability was moderate (r = 0.70). The SOS-Q showed superior concurrent validity with the highest correlation between the S-Scale (r = 0.76). Receiver operating characteristic curve analysis revealed an area under the curve of 0.877. A cut-off point of 49 effectively categorized addiction high-risk group with a sensitivity of 0.81 and specificity of 0.86. Overall, the current study supports the use of SOS-Q as both a primary and supplementary measurement tool in a variety of settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Method validation for chemical composition determination by electron microprobe with wavelength dispersive spectrometer

    Science.gov (United States)

    Herrera-Basurto, R.; Mercader-Trejo, F.; Muñoz-Madrigal, N.; Juárez-García, J. M.; Rodriguez-López, A.; Manzano-Ramírez, A.

    2016-07-01

    The main goal of method validation is to demonstrate that the method is suitable for its intended purpose. One of the advantages of analytical method validation is translated into a level of confidence about the measurement results reported to satisfy a specific objective. Elemental composition determination by wavelength dispersive spectrometer (WDS) microanalysis has been used over extremely wide areas, mainly in the field of materials science, impurity determinations in geological, biological and food samples. However, little information is reported about the validation of the applied methods. Herein, results of the in-house method validation for elemental composition determination by WDS are shown. SRM 482, a binary alloy Cu-Au of different compositions, was used during the validation protocol following the recommendations for method validation proposed by Eurachem. This paper can be taken as a reference for the evaluation of the validation parameters more frequently requested to get the accreditation under the requirements of the ISO/IEC 17025 standard: selectivity, limit of detection, linear interval, sensitivity, precision, trueness and uncertainty. A model for uncertainty estimation was proposed including systematic and random errors. In addition, parameters evaluated during the validation process were also considered as part of the uncertainty model.

  18. Validity of the use of the neutron reduction factor in assessing displacement damage to electronics in armoured vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, T.; Jamieson, T.J.

    1990-01-01

    To predict the degree of protection afforded to electronics by armoured vehicles exposed to neutron irradiation, the ratio of outside to inside tissue kermas has often been used as an approximation. This report examines the validity of this approximation by using the computer code VPF2 to generate neutron fields to be expected in a number of battlefield scenarios. The performance of 2 neutron dosimeters in these fields is also examined.

  19. Analytical electron microscope study of eight ataxites

    Science.gov (United States)

    Novotny, P. M.; Goldstein, J. I.; Williams, D. B.

    1982-01-01

    Optical and electron optical (SEM, TEM, AEM) techniques were employed to investigate the fine structure of eight ataxite-iron meteorites. Structural studies indicated that the ataxites can be divided into two groups: a Widmanstaetten decomposition group and a martensite decomposition group. The Widmanstaetten decomposition group has a Type I plessite microstructure and the central taenite regions contain highly dislocated lath martensite. The steep M shaped Ni gradients in the taenite are consistent with the fast cooling rates, of not less than 500 C/my, observed for this group. The martensite decomposition group has a Type III plessite microstructure and contains all the chemical group IVB ataxites. The maximum taenite Ni contents vary from 47.5 to 52.7 wt % and are consistent with slow cooling to low temperatures of not greater than 350 C at cooling rates of not greater than 25 C/my.

  20. Optimization and validation of the protocol used to analyze the taste of traditional Chinese medicines using an electronic tongue.

    Science.gov (United States)

    Li, Xuelin; Gao, Xiaojie; Liu, Ruixin; Wang, Junming; Wu, Zidan; Zhang, Lu; Li, Huiling; Gui, Xinjing; Kang, Bingya; Shi, Junhan

    2016-11-01

    Tools to define the active ingredients and flavors of Traditional Chinese Medicines (TCMs) are limited by long analysis times, complex sample preparation and a lack of multiplexed analysis. The aim of the present study was to optimize and validate an electronic tongue (E-tongue) methodology to analyze the bitterness of TCMs. To test the protocol, 35 different TCM concoctions were measured using an E-tongue, and seven replicate measurements of each sample were taken to evaluate reproducibility and precision. E-tongue sensor information was identified and classified using analysis approaches including least squares support vector machine (LS-SVM), support vector machine (SVM), discriminant analysis (DA) and partial least squares (PLS). A benefit of this analytical protocol was that the analysis of a single sample took <15 min for all seven sensors. The results identified that the LS-SVM approach provided the best bitterness classification accuracy (binary classification accuracy, 100%; ternary classification accuracy, 89.66%). The E-tongue protocol developed showed good reproducibility and high precision within a 6 h measurement cycle. To the best of our knowledge, this is the first study of an E-tongue being applied to assay the bitterness of TCMs. This approach could be applied in the classification of the taste of TCMs, and serve important roles in other fields, including foods and beverages.

  1. Study of electron-positron interactions

    International Nuclear Information System (INIS)

    Abashian, A.; Gotow, K.; Philonen, L.

    1990-01-01

    For the past seven years, this group has been interested in the study of tests of the Standard Model of Electroweak interactions. The program has centered about the AMY experiment which examines the nature of the final state products in electron-positron collisions in the center of mass energy range near 60 GeV. Results of these measurements have shown a remarkable consistency with the predictions of the minimal model of 3 quark and lepton generations and single charged and neutral intermediate bosons. No new particles or excited states have been observed nor has any evidence for departures in cross sections or angular asymmetries from expectations been observed. These conclusions have been even more firmly established by the higher energy results from the LEP and SLC colliders at center of mass energies of about 90 GeV. Our focus is shifting to the neutrino as a probe to electroweak interactions. The relative merit of attempting to observe neutrinos from point sources versus observing neutrinos generally is not easy to predict. The improved ability to interpret is offset by the probably episodic nature of the emission and irreproducibility of the results. In this phase of development, it is best to be sensitive to both sources of neutrinos. As a second phase of our program at Virginia Tech, we are studying the feasibility of detecting cosmic ray neutrinos in a proposed experiment which we have called NOVA. the results of the test setup will be instrumental in developing an optimum design. A third program we are involved in is the MEGA experiment at Los Alamos, an experiment to place a limit on the rate of muon decay to electron plus photon which is forbidden by the Standard Model

  2. Electronic structure studies of fullerites and fullerides

    International Nuclear Information System (INIS)

    Merkel, M.; Sohmen, E.; Masaki, A.; Romberg, H.; Alexander, M.; Knupfer, M.; Golden, M.S.; Adelmann, P.; Renker, B.; Fink, J.

    1993-01-01

    The electronic structure of fullerites and fullerides has been investigated by high-resolution photoemission and by high-energy electron energy-loss spectroscopy in transmission. Information on the occupied Π and σ bands, on the unoccupied Π * and σ * bands, and on the joint density of states has been obtained. In particular, we report on the changes of the electronic structure of fullerides as a function of dopant concentration. (orig.)

  3. External validity of post-stroke interventional gait rehabilitation studies.

    Science.gov (United States)

    Kafri, Michal; Dickstein, Ruth

    2017-01-01

    Gait rehabilitation is a major component of stroke rehabilitation, and is supported by extensive research. The objective of this review was to examine the external validity of intervention studies aimed at improving gait in individuals post-stroke. To that end, two aspects of these studies were assessed: subjects' exclusion criteria and the ecological validity of the intervention, as manifested by the intervention's technological complexity and delivery setting. Additionally, we examined whether the target population as inferred from the titles/abstracts is broader than the population actually represented by the reported samples. We systematically researched PubMed for intervention studies to improve gait post-stroke, working backwards from the beginning of 2014. Exclusion criteria, the technological complexity of the intervention (defined as either elaborate or simple), setting, and description of the target population in the titles/abstracts were recorded. Fifty-two studies were reviewed. The samples were exclusive, with recurrent stroke, co-morbidities, cognitive status, walking level, and residency being major reasons for exclusion. In one half of the studies, the intervention was elaborate. Descriptions of participants in the title/abstract in almost one half of the studies included only the diagnosis (stroke or comparable terms) and its stage (acute, subacute, and chronic). The external validity of a substantial number of intervention studies about rehabilitation of gait post-stroke appears to be limited by exclusivity of the samples as well as by deficiencies in ecological validity of the interventions. These limitations are not accurately reflected in the titles or abstracts of the studies.

  4. Distress Tolerance Scale: A Study of Reliability and Validity

    Directory of Open Access Journals (Sweden)

    Ahmet Emre SARGIN

    2012-11-01

    Full Text Available Objective: Distress Tolerance Scale (DTS is developed by Simons and Gaher in order to measure individual differences in the capacity of distress tolerance.The aim of this study is to assess the reliability and validity of the Turkish version of DTS. Method: One hundred and sixty seven university students (male=66, female=101 participated in this study. Beck Anxiety Inventory (BAI, State-trait Anxiety Inventory (STAI and Discomfort Intolerance Scale (DIS were used to determine the criterion validity. Construct validity was evaluated with factor analysis after the Kaiser-Meyer-Olkin (KMO and Barlett test had been performed. To assess the test-retest reliability, the scale was re-applied to 79 participants six weeks later. Results: To assess construct validity, factor analyses were performed using varimax principal components analysis with varimax rotation. While there were factors in the original study, our factor analysis resulted in three factors. Cronbach’s alpha coefficients for the entire scale and tolerance, regulation, self-efficacy subscales were .89, .90, .80 and .64 respectively. There were correlations at the level of 0.01 between the Trait Anxiety Inventory of STAI and BAI, and all the subscales of DTS and also between the State Anxiety Inventory and regulation subscale. Both of the subscales of DIS were correlated with the entire subscale and all the subscales except regulation at the level of 0.05.Test-retest reliability was statistically significant at the level of 0.01. Conclusion: Analysis demonstrated that DTS had a satisfactory level of reliability and validity in Turkish university students.

  5. Zeolites - a high resolution electron microscopy study

    International Nuclear Information System (INIS)

    Alfredsson, V.

    1994-10-01

    High resolution transmission electron microscopy (HRTEM) has been used to investigate a number of zeolites (EMT, FAU, LTL, MFI and MOR) and a member of the mesoporous M41S family. The electron optical artefact, manifested as a dark spot in the projected centre of the large zeolite channels, caused by insufficient transfer of certain reflections in the objective lens has been explained. The artefact severely hinders observation of materials confined in the zeolite channels and cavities. It is shown how to circumvent the artefact problem and how to image confined materials in spite of disturbance caused by the artefact. Image processing by means of a Wiener filter has been applied for removal of the artefact. The detailed surface structure of FAU has been investigated. Comparison of experimental micrographs with images simulated using different surface models indicates that the surface can be terminated in different ways depending on synthesis methods. The dealuminated form of FAU (USY) is covered by an amorphous region. Platinum incorporated in FAU has a preponderance to aggregate in the (111) twin planes, probably due to a local difference in cage structure with more spacious cages. It is shown that platinum is intra-zeolitic as opposed to being located on the external surface of the zeolite crystal. This could be deduced from tomography of ultra-thin sections among observations. HRTEM studies of the mesoporous MCM-41 show that the pores have a hexagonal shape and also supports the mechanistic model proposed which involves a cooperative formation of a mesophase including the silicate species as well as the surfactant. 66 refs, 24 figs

  6. Validity of Basic Electronic 1 Module Integrated Character Value Based on Conceptual Change Teaching Model to Increase Students Physics Competency in STKIP PGRI West Sumatera

    Science.gov (United States)

    Hidayati, A.; Rahmi, A.; Yohandri; Ratnawulan

    2018-04-01

    The importance of teaching materials in accordance with the characteristics of students became the main reason for the development of basic electronics I module integrated character values based on conceptual change teaching model. The module development in this research follows the development procedure of Plomp which includes preliminary research, prototyping phase and assessment phase. In the first year of this research, the module is validated. Content validity is seen from the conformity of the module with the development theory in accordance with the demands of learning model characteristics. The validity of the construct is seen from the linkage and consistency of each module component developed with the characteristic of the integrated learning model of character values obtained through validator assessment. The average validation value assessed by the validator belongs to a very valid category. Based on the validator assessment then revised the basic electronics I module integrated character values based on conceptual change teaching model.

  7. Dental Wear: A Scanning Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Luca Levrini

    2014-01-01

    Full Text Available Dental wear can be differentiated into different types on the basis of morphological and etiological factors. The present research was carried out on twelve extracted human teeth with dental wear (three teeth showing each type of wear: erosion, attrition, abrasion, and abfraction studied by scanning electron microscopy (SEM. The study aimed, through analysis of the macro- and micromorphological features of the lesions (considering the enamel, dentin, enamel prisms, dentinal tubules, and pulp, to clarify the different clinical and diagnostic presentations of dental wear and their possible significance. Our results, which confirm current knowledge, provide a complete overview of the distinctive morphology of each lesion type. It is important to identify the type of dental wear lesion in order to recognize the contributing etiological factors and, consequently, identify other more complex, nondental disorders (such as gastroesophageal reflux, eating disorders. It is clear that each type of lesion has a specific morphology and mechanism, and further clinical studies are needed to clarify the etiological processes, particularly those underlying the onset of abfraction.

  8. A Study on Guide Sign Validity in Driving Simulator

    Directory of Open Access Journals (Sweden)

    Wei Zhonghua

    2011-12-01

    Full Text Available The role of guide sign to inform road user about the information of network is important. How to design and locate guide sign to increase traffic operation efficiency is a key point for traffic engineers. Driving simulator is useful devised to study guide sign in the process and system control. For the purpose of studying guide signs using the tool of driving simulator, guide sign's validity in driving simulator was studied. Results of this experiment are the foundation of further study on guide sign. Simulator calibration procedure for guide sign was set up in this study. Legibility distance as measure of performance was used to evaluate the validity of guide sign in driving simulator. Thirty two participants were recruited. Results indicated legibility distance and speed were inversely related with the method of data mining. Legibility distance and text height of guide sign were positive related. When speed is 20km/h, 30km/h, 40km/h, magnifying power of text height is 4.3, 4.1, 3.8, while guide signs are absolute validity in driving simulator.

  9. Sounding rocket study of auroral electron precipitation

    International Nuclear Information System (INIS)

    McFadden, J.P.

    1985-01-01

    Measurement of energetic electrons in the auroral zone have proved to be one of the most useful tools in investigating the phenomena of auroral arc formation. This dissertation presents a detailed analysis of the electron data from two sounding rocket campaigns and interprets the measurements in terms of existing auroral models. The Polar Cusp campaign consisted of a single rocket launched from Cape Parry, Canada into the afternoon auroral zone at 1:31:13 UT on January 21, 1982. The results include the measurement of a narrow, magnetic field aligned electron flux at the edge of an arc. This electron precipitation was found to have a remarkably constant 1.2 eV temperature perpendicular to the magnetic field over a 200 to 900 eV energy range. The payload also made simultaneous measurements of both energetic electrons and 3-MHz plasma waves in an auroral arc. Analysis has shown that the waves are propagating in the upper hybrid band and should be generated by a positive slope in the parallel electron distribution. A correlation was found between the 3-MHz waves and small positive slopes in the parallel electron distribution but experimental uncertainties in the electron measurement were large enough to influence the analysis. The BIDARCA campaign consisted of two sounding rockets launched from Poker Flat and Fort Yukon, Alaska at 9:09:00 UT and 9:10:40 UT on February 7, 1984

  10. Development and Validation of an ICP-MS Method for Simultaneous Determination of Selected Metals in Electronic Cigarette Aerosol

    Directory of Open Access Journals (Sweden)

    Ohashi Shintaro

    2018-04-01

    Full Text Available Safety and quality standards for electronic cigarettes (e-cigarettes have been introduced regionally. In 2016, the U.S. Food and Drug Administration (FDA issued a rule to regulate e-cigarettes, requiring to report harmful and potentially harmful constituents (HPHCs. In the United Kingdom, the British Standards Institution (BSI specified the metals to be monitored for e-cigarettes. In this study, a method was developed and validated for the simultaneous determination of 13 metals (Be, Al, Cr, Fe, Co, Ni, Cu, As, Se, Ag, Cd, Sn and Pb in e-cigarette aerosol. Furthermore, matrix effects of major constituents in the aerosol were investigated using glycerol or 1,2-propylene glycol solutions. E-cigarette aerosol was generated by a rotary smoking machine according to CORESTA Recommended Method N° 81 and collected by an electrostatic precipitator coupled to an impinger containing nitric acid. The collected aerosol was dissolved in nitric acid and an aliquot of this solution was analyzed by inductively coupled plasma mass spectrometry (ICP-MS equipped with a collision/reaction cell.

  11. Electronic Dietary Intake Assessment (e-DIA): relative validity of a mobile phone application to measure intake of food groups.

    Science.gov (United States)

    Rangan, Anna M; Tieleman, Laurissa; Louie, Jimmy C Y; Tang, Lie Ming; Hebden, Lana; Roy, Rajshri; Kay, Judy; Allman-Farinelli, Margaret

    2016-06-01

    Automation of dietary assessment can reduce limitations of established methodologies, by alleviating participant and researcher burden. Designed as a research tool, the electronic Dietary Intake Assessment (e-DIA) is a food record in mobile phone application format. The present study aimed to examine the relative validity of the e-DIA with the 24-h recall method to estimate intake of food groups. A sample of eighty university students aged 19-24 years recorded 5 d of e-DIA and 3 d of recall within this 5-d period. The three matching days of dietary data were used for analysis. Food intake data were disaggregated and apportioned to one of eight food groups. Median intakes of food groups were similar between the methods, and strong correlations were found (mean: 0·79, range: 0·69-0·88). Cross-classification by tertiles produced a high level of exact agreement (mean: 71 %, range: 65-75 %), and weighted κ values were moderate to good (range: 0·54-0·71). Although mean differences (e-DIA-recall) were small (range: -13 to 23 g), limits of agreement (LOA) were relatively large (e.g. for vegetables, mean difference: -4 g, LOA: -159 to 151 g). The Bland-Altman plots showed robust agreement, with minimum bias. This analysis supports the use of e-DIA as an alternative to the repeated 24-h recall method for ranking individuals' food group intake.

  12. Electron spectroscopy studies in heavy fermions

    International Nuclear Information System (INIS)

    Arko, A.J.

    1986-02-01

    Photoemission experiments (whereby an electron absorbs a packet of light energy and is able to escape from the host material due to its increased energy) can measure directly the energy distribution of electrons in various materials. Our measurements on a recently-discovered class of metallic materials called ''heavy fermions'' show that the electrons that actually carry the electric current in these metals exist only within an extremely narrow range of energies. This range, which we will call the bandwidth, is narrower than that found in ordinary metals like copper by at least a factor of 10. Indeed it is surprising that they can carry electric current at all since such narrow energy ranges (or band widths) are characteristic of electrons confined to their host atoms, as in a non-metal, rather than of electrons that are free to wander through a metal. 8 refs

  13. The validity of vignettes in cross country health studies

    DEFF Research Database (Denmark)

    Pozzoli, Dario; Gupta, Nabanita Datta; Kristensen, Nicolai

    Cross-country comparisons of subjective assessments may be ham-pered by sub-population speci.c response style. To correct for this, the use of vignettes has become increasingly popular - notably within cross-country health studies. However, the validity of vignettes as a means to re-scale across ...... that the assumption of RC is not innocous and that our extended model improves the fit and significantly changes the cross-country rankings of health vis-á-vis the standard Chopit model.......Cross-country comparisons of subjective assessments may be ham-pered by sub-population speci.c response style. To correct for this, the use of vignettes has become increasingly popular - notably within cross-country health studies. However, the validity of vignettes as a means to re-scale across...

  14. Content validity and electronic PRO (ePRO) usability of the Lung Cancer Symptom Scale-Mesothelioma (LCSS-Meso) in mesothelioma patients.

    Science.gov (United States)

    Gelhorn, Heather L; Skalicky, Anne M; Balantac, Zaneta; Eremenco, Sonya; Cimms, Tricia; Halling, Katarina; Hollen, Patricia J; Gralla, Richard J; Mahoney, Martin C; Sexton, Chris

    2018-02-01

    Obtaining qualitative data directly from the patient perspective enhances the content validity of patient-reported outcome (PRO) instruments. The objective of this qualitative study was to evaluate the content validity of the Lung Cancer Symptom Scale for Mesothelioma (LCSS-Meso) and its usability on an electronic device. A cross-sectional methodological study, using a qualitative approach, was conducted among patients recruited from four clinical sites. The primary target population included patients with pleural mesothelioma; data were also collected from patients with peritoneal mesothelioma on an exploratory basis. Semi-structured interviews were conducted consisting of concept elicitation, cognitive interviewing, and evaluation of electronic patient-reported outcome (ePRO) usability. Participants (n = 21) were interviewed in person (n = 9) or by telephone (n = 12); 71% were male with a mean age of 69 years (SD = 14). The most common signs and symptoms experienced by participants with pleural mesothelioma (n = 18) were shortness of breath, fluid build-up, pain, fatigue, coughing, and appetite loss. The most commonly described symptoms for those with peritoneal mesothelioma (n = 4) were bloating, changes in appetite, fatigue, fluid build-up, shortness of breath, and pain. Participants with pleural mesothelioma commonly described symptoms assessed by the LCSS-Meso in language consistent with the questionnaire and a majority understood and easily completed each of the items. The ePRO version was easy to use, and there was no evidence that the electronic formatting changed the way participants responded to the questions. Results support the content validity of the LCSS-Meso and the usability of the electronic format for use in assessing symptoms among patients with pleural mesothelioma.

  15. The birth satisfaction scale: Turkish adaptation, validation and reliability study

    Science.gov (United States)

    Cetin, Fatma Cosar; Sezer, Ayse; Merih, Yeliz Dogan

    2015-01-01

    OBJECTIVE: The objective of this study is to investigate the validity and the reliability of Birth Satisfaction Scale (BSS) and to adapt it into the Turkish language. This scale is used for measuring maternal satisfaction with birth in order to evaluate women’s birth perceptions. METHODS: In this study there were 150 women who attended to inpatient postpartum clinic. The participants filled in an information form and the BSS questionnaire forms. The properties of the scale were tested by conducting reliability and validation analyses. RESULTS: BSS entails 30 Likert-type questions. It was developed by Hollins Martin and Fleming. Total scale scores ranged between 30–150 points. Higher scores from the scale mean increases in birth satisfaction. Three overarching themes were identified in Scale: service provision (home assessment, birth environment, support, relationships with health care professionals); personal attributes (ability to cope during labour, feeling in control, childbirth preparation, relationship with baby); and stress experienced during labour (distress, obstetric injuries, receiving sufficient medical care, obstetric intervention, pain, prolonged labour and baby’s health). Cronbach’s alfa coefficient was 0.62. CONCLUSION: According to the present study, BSS entails 30 Likert-type questions and evaluates women’s birth perceptions. The Turkish version of BSS has been proven to be a valid and a reliable scale. PMID:28058355

  16. Videoconference-based mini mental state examination: a validation study.

    Science.gov (United States)

    Timpano, Francesca; Pirrotta, Fabio; Bonanno, Lilla; Marino, Silvia; Marra, Angela; Bramanti, Placido; Lanzafame, Pietro

    2013-12-01

    Neuropsychological testing is a prime criterion of good practice to document cognitive deficits in a rapidly aging population. Telecommunication technologies may overcome limitations related to test administration. We compared performance of the Italian videoconference-based version of the Mini Mental State Examination (VMMSE) with performance of the standard MMSE administered face-to-face (F2F), to validate the Italian version of the 28-item VMMSE. To validate the Italian version of the VMMSE, we compared its performance with standard F2F. The sample (n=342) was administered three VMMSEs within 6 weeks after F2F testing. We identified the optimal cutoff through the receiver operating characteristic curve, as well as the VMMSE consistency through inter- and intrarater reliability (Inter/RR and Intra/RR) analysis. We found high levels of sensitivity and specificity for the optimal VMMSE cutoff identification and an accuracy of 0.96 (95% confidence interval 0.94-0.98). Intra/RR and inter/RR were highly significant. This study demonstrates that VMMSE is a valid instrument in clinical and research screening and monitoring of subjects affected by cognitive disorders. This study shows a significant correlation between videoconference assessment and the F2F one, providing an important impetus to expand studies and the knowledge about the usefulness of tele-assistance services. Our findings have important implications for both longitudinal assistance and clinical care of demented patients.

  17. Titanium pigmentation. An electron probe microanalysis study

    International Nuclear Information System (INIS)

    Dupre, A.; Touron, P.; Daste, J.; Lassere, J.; Bonafe, J.L.; Viraben, R.

    1985-01-01

    A patient had an unusual pigmentary disease induced by titanium dioxide. The use of a topical cream containing titanium dioxide caused a xanthomalike appearance on the patient's penis. Electron probe microanalysis was valuable in establishing the cause of this balanitis

  18. Study of electron and neutrino interactions

    International Nuclear Information System (INIS)

    Abashian, A.

    1997-01-01

    This is the final report for the DOE-sponsored experimental particle physics program at Virginia Tech to study the properties of the Standard Model of strong and electroweak interactions. This contract (DE-AS05-80ER10713) covers the period from August 1, 1980 to January 31, 1993. Task B of this contract, headed by Professor Alexander Abashian, is described in this final report. This program has been pursued on many fronts by the researchers-in a search for axions at SLAC, in electron-positron collisions in the AMY experiment at the TRISTAN collider in Japan, in measurements of muon decay properties in the MEGA and RHO experiments at the LAMPF accelerator, in a detailed analysis of scattering effects in the purported observation of a 17 keV neutrino at Oxford, in a search for a disoriented chiral condensate with the MiniMax experiment at Fermilab, and in an R ampersand D program on resistive plate counters that could find use in low-cost high-quality charged particle detection at low rates

  19. Methods of defining hypertension in electronic medical records: validation against national survey data.

    Science.gov (United States)

    Peng, Mingkai; Chen, Guanmin; Kaplan, Gilaad G; Lix, Lisa M; Drummond, Neil; Lucyk, Kelsey; Garies, Stephanie; Lowerison, Mark; Weibe, Samuel; Quan, Hude

    2016-09-01

    Electronic medical records (EMR) can be a cost-effective source for hypertension surveillance. However, diagnosis of hypertension in EMR is commonly under-coded and warrants the needs to review blood pressure and antihypertensive drugs for hypertension case identification. We included all the patients actively registered in The Health Improvement Network (THIN) database, UK, on 31 December 2011. Three case definitions using diagnosis code, antihypertensive drug prescriptions and abnormal blood pressure, respectively, were used to identify hypertension patients. We compared the prevalence and treatment rate of hypertension in THIN with results from Health Survey for England (HSE) in 2011. Compared with prevalence reported by HSE (29.7%), the use of diagnosis code alone (14.0%) underestimated hypertension prevalence. The use of any of the definitions (38.4%) or combination of antihypertensive drug prescriptions and abnormal blood pressure (38.4%) had higher prevalence than HSE. The use of diagnosis code or two abnormal blood pressure records with a 2-year period (31.1%) had similar prevalence and treatment rate of hypertension with HSE. Different definitions should be used for different study purposes. The definition of 'diagnosis code or two abnormal blood pressure records with a 2-year period' could be used for hypertension surveillance in THIN. © The Author 2015. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Using clinician text notes in electronic medical record data to validate transgender-related diagnosis codes.

    Science.gov (United States)

    Blosnich, John R; Cashy, John; Gordon, Adam J; Shipherd, Jillian C; Kauth, Michael R; Brown, George R; Fine, Michael J

    2018-04-04

    Transgender individuals are vulnerable to negative health risks and outcomes, but research remains limited because data sources, such as electronic medical records (EMRs), lack standardized collection of gender identity information. Most EMR do not include the gold standard of self-identified gender identity, but International Classification of Diseases (ICDs) includes diagnostic codes indicating transgender-related clinical services. However, it is unclear if these codes can indicate transgender status. The objective of this study was to determine the extent to which patients' clinician notes in EMR contained transgender-related terms that could corroborate ICD-coded transgender identity. Data are from the US Department of Veterans Affairs Corporate Data Warehouse. Transgender patients were defined by the presence of ICD9 and ICD10 codes associated with transgender-related clinical services, and a 3:1 comparison group of nontransgender patients was drawn. Patients' clinician text notes were extracted and searched for transgender-related words and phrases. Among 7560 patients defined as transgender based on ICD codes, the search algorithm identified 6753 (89.3%) with transgender-related terms. Among 22 072 patients defined as nontransgender without ICD codes, 246 (1.1%) had transgender-related terms; after review, 11 patients were identified as transgender, suggesting a 0.05% false negative rate. Using ICD-defined transgender status can facilitate health services research when self-identified gender identity data are not available in EMR.

  1. A GLOBAL TWO-TEMPERATURE CORONA AND INNER HELIOSPHERE MODEL: A COMPREHENSIVE VALIDATION STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Jin, M.; Manchester, W. B.; Van der Holst, B.; Gruesbeck, J. R.; Frazin, R. A.; Landi, E.; Toth, G.; Gombosi, T. I. [Atmospheric Oceanic and Space Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Vasquez, A. M. [Instituto de Astronomia y Fisica del Espacio (CONICET-UBA) and FCEN (UBA), CC 67, Suc 28, Ciudad de Buenos Aires (Argentina); Lamy, P. L.; Llebaria, A.; Fedorov, A., E-mail: jinmeng@umich.edu [Laboratoire d' Astrophysique de Marseille, Universite de Provence, Marseille (France)

    2012-01-20

    The recent solar minimum with very low activity provides us a unique opportunity for validating solar wind models. During CR2077 (2008 November 20 through December 17), the number of sunspots was near the absolute minimum of solar cycle 23. For this solar rotation, we perform a multi-spacecraft validation study for the recently developed three-dimensional, two-temperature, Alfven-wave-driven global solar wind model (a component within the Space Weather Modeling Framework). By using in situ observations from the Solar Terrestrial Relations Observatory (STEREO) A and B, Advanced Composition Explorer (ACE), and Venus Express, we compare the observed proton state (density, temperature, and velocity) and magnetic field of the heliosphere with that predicted by the model. Near the Sun, we validate the numerical model with the electron density obtained from the solar rotational tomography of Solar and Heliospheric Observatory/Large Angle and Spectrometric Coronagraph C2 data in the range of 2.4 to 6 solar radii. Electron temperature and density are determined from differential emission measure tomography (DEMT) of STEREO A and B Extreme Ultraviolet Imager data in the range of 1.035 to 1.225 solar radii. The electron density and temperature derived from the Hinode/Extreme Ultraviolet Imaging Spectrometer data are also used to compare with the DEMT as well as the model output. Moreover, for the first time, we compare ionic charge states of carbon, oxygen, silicon, and iron observed in situ with the ACE/Solar Wind Ion Composition Spectrometer with those predicted by our model. The validation results suggest that most of the model outputs for CR2077 can fit the observations very well. Based on this encouraging result, we therefore expect great improvement for the future modeling of coronal mass ejections (CMEs) and CME-driven shocks.

  2. Intent inferencing by an intelligent operator's associate - A validation study

    Science.gov (United States)

    Jones, Patricia M.

    1988-01-01

    In the supervisory control of a complex, dynamic system, one potential form of aiding for the human operator is a computer-based operator's associate. The design philosophy of the operator's associate is that of 'amplifying' rather than automating human skills. In particular, the associate possesses understanding and control properties. Understanding allows it to infer operator intentions and thus form the basis for context-dependent advice and reminders; control properties allow the human operator to dynamically delegate individual tasks or subfunctions to the associate. This paper focuses on the design, implementation, and validation of the intent inferencing function. Two validation studies are described which empirically demonstrate the viability of the proposed approach to intent inferencing.

  3. Robustness study in SSNTD method validation: indoor radon quality

    International Nuclear Information System (INIS)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L.

    2017-01-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  4. Robustness study in SSNTD method validation: indoor radon quality

    Energy Technology Data Exchange (ETDEWEB)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L., E-mail: danilacdias@gmail.com [Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2017-07-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  5. Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media

    International Nuclear Information System (INIS)

    Chetty, Indrin J.; Moran, Jean M.; Nurushev, Teamor S.; McShan, Daniel L.; Fraass, Benedick A.; Wilderman, Scott J.; Bielajew, Alex F.

    2002-01-01

    A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racetrack microtron. Source distributions for the Monte Carlo calculations were reconstructed from in-air ion chamber scans and then benchmarked against measurements in a homogeneous water phantom. The in-air spatial distributions were found to have FWHM of 4.7 cm and 1.3 cm, at 100 cm from the source, for the 10 MeV and 50 MeV beams respectively. Energy spectra for the electron beams were determined by simulating the components of the microtron treatment head using the code MCNP4B. Profile measurements were made using an ion chamber in a water phantom with slabs of lung or bone-equivalent materials submerged at various depths. DPM calculations are, on average, within 2% agreement with measurement for all geometries except for the 50 MeV incident on a 6 cm lung-equivalent slab. Measurements using approximately monoenergetic, 50 MeV, 'pencil-beam'-type electrons in heterogeneous media provide conditions for maximum electronic disequilibrium and hence present a stringent test of the code's electron transport physics; the agreement noted between calculation and measurement illustrates that the DPM code is capable of accurate dose calculation even under such conditions. (author)

  6. DEVELOPING VISUAL PRESENTATION ATTITUDE RUBRIC: VALIDITY AND RELIABILITY STUDY

    OpenAIRE

    ATEŞ, Hatice KADIOĞLU; ADA, Sefer; BAYSAL, Z. Nurdan

    2015-01-01

    Abstract The aim of this study is to develop visual presentation attitude rubric which is valid and reliable for the 4th grade students. 218 students took part in this study from Engin Can Güre which located in Istanbul, Esenler. While preparing this assessment tool with 34 criterias , 6 university lecturers view have been taken who are experts in their field. The answer key sheet has 4 (likert )type options. The rubric has been first tested by Kaiser-Meyer Olkin and Bartletts tests an...

  7. Electron Cloud Parameterization Studies in the LHC

    CERN Document Server

    Dominguez, O; Baglin, V; Bregliozzi, G; Jimenez, J M; Metral, E; Rumolo, G; Schulte, D; Zimmermann, F

    2011-01-01

    During LHC beam commissioning with 150, 75 and 50-ns bunch spacing, important electron-cloud effects, like pressure rise, cryogenic heat load, beam instabilities or emittance growth, were observed. The main strategy to combat the LHC electron cloud, defined about ten years ago, relies on the surface conditioning arising from the chamber-surface bombardment with cloud electrons. In a standard model, the conditioning state of the beam-pipe surface is characterized by three parameters: 1. most importantly, the secondary emission yield δmax; 2. the incident electron energy at which the yield is maximum, ε_max; and 3. the probability of elastic reflection of low-energy primary electrons hitting the chamber wall, R. Since at the LHC no in-situ secondary-yield measurements are available, we compare the relative local pressure-rise measurements taken for different beam configurations against simulations in which surface parameters are scanned. This benchmarking of measurements and simulations is used to infer the s...

  8. Validation of physical activity instruments: Black Women's Health Study.

    Science.gov (United States)

    Carter-Nolan, Pamela L; Adams-Campbell, Lucile L; Makambi, Kepher; Lewis, Shantell; Palmer, Julie R; Rosenberg, Lynn

    2006-01-01

    Few studies have reported on the validity of physical activity measures in African Americans. The present study was designed to determine the validity of a self-administered physical activity questionnaire (PAQ) that was used in a large prospective study of African American women in the United States against an accelerometer (actigraph), an objective assessment of movement, and a seven-day activity diary. The study was conducted among 101 women enrolled in the Black Women's Health Study (BWHS) cohort who resided in the Washington, DC, metropolitan area, representing 11.2% (101/900) of this sample. Physical activity levels were obtained from the parent BWHS PAQ (eg, 1997 and 1999) and repeated in the present study. This information entailed hours per week of participation in walking for exercise, hours per week of moderate activity (eg, housework, gardening, and bowling), and hours per week of strenuous activity (eg, basketball, swimming, running, and aerobics) during the previous year. The participants were required to wear actigraphs for seven days and then record their physical activities in their diaries (seven-day physical activity diary) during this time. The diaries were used to record the amount and pattern of daily energy expenditure. Significant positive correlations were seen between the BWHS PAQ and the actigraph for total activity, r=.28; walking, r=.26; and vigorous activity, r=.40, PPAQ also demonstrated significant correlations for total (r=0.42, PPAQ is a useful measure of physical activity in the BWHS cohort and thus has utility in prospective epidemiologic research.

  9. Study of nuclei by electron scattering

    International Nuclear Information System (INIS)

    Torizuka, Yoshiharu; Saito, Teijiro; Ito, Kohei; Terasawa, Tatsuo; Hosoyama, Kenji.

    1974-01-01

    It is urgently required to clarify the physical meaning of the quasi-elastic scattering associated with the background, in order to develop rapidly the study of giant resonance. The experimental works performed in the present term aimed at the synthetic understanding of both giant resonance and quasi-elastic scattering, and presented the possibility of the separability of giant resonance from quasi-elastic scattering. The object of this experiment was to measure higher order multi-pole moment of 51 V by using relatively high energy electron beam. Targets of chemically pure 51 V had thickness of 68.2 or 100.5 mg/cm 2 . The measurement was made at the position where scattering angle was 155 0 . The state of M7 can be well explained by the model with (fsub(7/2)) 3 coordination. This may be because the nuclei with stretched configuration such as 51 V do not have any contribution of orbital motion, but have the contribution of eigen magnetic moment to the highest multiplicity. States of M3 and M5 are a little complicated. Since in the experimental equipment used, the contribution of charge distribution was so large, that it was difficult to make the precision measurement of M3 and M5. In 51 V, however, it can be considered that M3 and M5 decreased by the contribution of 2Psub(3/2) and 1fsub(5/2). On the other hand, there is no contribution from these energy states to M7. (Tai, I.)

  10. Electron microscopy studies of ion implanted silicon

    International Nuclear Information System (INIS)

    Seshan, K.

    1975-11-01

    The nature of defects resulting from the implantation of phosphorous ions into doped silicon and a model of how they form are reported. This involved an electron microscope study of the crystallographic defects (in the 300A size range in concentration of 10 15 /cm 3 ) that form upon annealing. Images formed by these crystallographic defects are complex and that nonconventional imaging techniques are required for their characterization. The images of these small defects (about 300A) are sensitive to various parameters, such as foil thickness, their position in the foil, and diffracting conditions. The defects were found to be mostly interstitial hexagonal Frank loops lying on the four [111] planes and a few perfect interstitial loops; these loops occurred in concentrations of about 10 16 /cm 3 . In addition, ''rod like'' linear defects that are shown to be interstitial are also found in concentrations of 10 13 /cm 3 . It was found that the linear defects require boron for their formation. A model is proposed to account for the interstitial defects. The number of point defects that make up the defects is of the same order as the number of implanted ions. The model predicts that only interstitial loops ought to be observed in agreement with several recent investigations. Dislocation models of the loops are examined and it is shown that phosphorous ions could segregate to the Frank loops, changing their displacement vectors to a/x[111]. (x greater than 3) thus explaining the contrast effects observed. It would also explain the relative electrical inactivity of P + ion implants

  11. Electron impact study of potassium hydroxide

    Science.gov (United States)

    Vuskovic, L.; Trajmar, S.

    1979-01-01

    An attempt is made to measure the sum of the elastic, rotational and vibrational scattering of electrons by KOH at low impact energies (5 to 20 eV) at angles from 10 to 120 deg. Energy loss spectra taken in the 0 to 18 eV range using an electron impact spectrometer are used to identify the species contributing to electric scattering. At temperatures between 300 and 500 C, only inelastic spectral features belonging to water are detected, while at temperatures from 500 to 800 C strong atomic K lines, indicative of molecular dissociation, and H2 energy loss features become prominent. No features attributable to KOH, the KOH dimer, O2 or potassium oxides were observed, due to the effects of the dissociation products, and it is concluded that another technique will have to be developed in order to measure electron scattering by KOH.

  12. Validity of the use of the neutron-reduction factor in assessing displacement damage to electronics in armoured vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, T.; Jamieson, T.J.

    1990-02-01

    The degree of protection from neutron irradiation afforded to electronics by armoured vehicles is most currently defined by the outside-to-inside ratio of the 1 MeV equivalent neutron fluence for Silicon. It has been proposed that this factor may be approximated by an experimentally measurable parameter - the neutron (tissue kerma) reduction factor. This report examines the validity of this assumption for a variety of realistic nuclear battlefield scenarios, calculated using the computer code VPF2. In addition the response of two neutron dosimeters in the calculated fields is examined.

  13. Theoretical study of the electron paramagnetic resonance ...

    Indian Academy of Sciences (India)

    conveniently investigated by means of electron paramagnetic resonance (EPR). In ... ion Ir2+ can experience the Jahn–Teller effect by means of vibration interaction, ... Similarly, k. (and k ) are the orbital reduction factors arising from the anisotropic interactions of the orbital angular momentum operator. From the cluster ...

  14. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis

    NARCIS (Netherlands)

    de Vries, R.; Brinkman, P.; van der Schee, M. P.; Fens, N.; Dijkers, E.; Bootsma, S. K.; de Jongh, F. H. C.; Sterk, P. J.

    2015-01-01

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We

  15. Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model.

    Science.gov (United States)

    Abid, Abubakar; O'Brien, Jonathan M; Bensel, Taylor; Cleveland, Cody; Booth, Lucas; Smith, Brian R; Langer, Robert; Traverso, Giovanni

    2017-04-27

    Electronic devices placed in the gastrointestinal (GI) tract for prolonged periods have the potential to transform clinical evaluation and treatment. One challenge to the deployment of such gastroresident electronics is the difficulty in powering millimeter-sized electronics devices without using batteries, which compromise biocompatibility and long-term residence. We examined the feasibility of leveraging mid-field wireless powering to transfer power from outside of the body to electronics at various locations along the GI tract. Using simulations and ex vivo measurements, we designed mid-field antennas capable of operating efficiently in tissue at 1.2 GHz. These antennas were then characterized in vivo in five anesthetized pigs, by placing one antenna outside the body, and the other antenna inside the body endoscopically, at the esophagus, stomach, and colon. Across the animals tested, mean transmission efficiencies of -41.2, -36.1, and -34.6 dB were achieved in vivo while coupling power from outside the body to the esophagus, stomach, and colon, respectively. This corresponds to power levels of 37.5 μW, 123 μW and 173 μW received by antennas in the respective locations, while keeping radiation exposure levels below safety thresholds. These power levels are sufficient to wirelessly power a range of medical devices from outside of the body.

  16. Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model

    Science.gov (United States)

    Abid, Abubakar; O'Brien, Jonathan M.; Bensel, Taylor; Cleveland, Cody; Booth, Lucas; Smith, Brian R.; Langer, Robert; Traverso, Giovanni

    2017-04-01

    Electronic devices placed in the gastrointestinal (GI) tract for prolonged periods have the potential to transform clinical evaluation and treatment. One challenge to the deployment of such gastroresident electronics is the difficulty in powering millimeter-sized electronics devices without using batteries, which compromise biocompatibility and long-term residence. We examined the feasibility of leveraging mid-field wireless powering to transfer power from outside of the body to electronics at various locations along the GI tract. Using simulations and ex vivo measurements, we designed mid-field antennas capable of operating efficiently in tissue at 1.2 GHz. These antennas were then characterized in vivo in five anesthetized pigs, by placing one antenna outside the body, and the other antenna inside the body endoscopically, at the esophagus, stomach, and colon. Across the animals tested, mean transmission efficiencies of -41.2, -36.1, and -34.6 dB were achieved in vivo while coupling power from outside the body to the esophagus, stomach, and colon, respectively. This corresponds to power levels of 37.5 μW, 123 μW and 173 μW received by antennas in the respective locations, while keeping radiation exposure levels below safety thresholds. These power levels are sufficient to wirelessly power a range of medical devices from outside of the body.

  17. Validation of holistic nursing competencies: role-delineation study, 2012.

    Science.gov (United States)

    Erickson, Helen Lorraine; Erickson, Margaret Elizabeth; Campbell, Joan A; Brekke, Mary E; Sandor, M Kay

    2013-12-01

    The American Holistic Nurses Credentialing Corporation (AHNCC), certifying body for nurses practicing within the precepts of holistic nursing, uses a systematic process to guide program development. A previous publication described their early work that distinguished basic and advanced holistic nursing and development of related examinations. A more recent publication described the work of AHNCC from 2004 to 2012, including a role-delineation study (RDS) that was undertaken to identify and validate competencies currently used by holistic nurses. A final report describes the RDS design, methods, and raw data information. This article discusses AHNCC's goals for undertaking the 2012 Holistic Nursing RDS and the implications for the certification programs.

  18. Studies in the electronic structure of matter

    International Nuclear Information System (INIS)

    Miller, D.L.

    1979-01-01

    KLL Auger transition rates for helium are computed using simple atomic orbital wavefunctions which take into account the difference in average electron--electron repulsion of initial and final states. The results are consistent with transition rates computed by other authors using a variety of many-electron techniques. It is suggested that wavefunctions determined in the manner described provide a useful representation of the autoionizing state within the first Bohr radius. A method for extracting atomic pseudopotentials from photoelectron angular distributions is described and applied photoionization of the outermost p shells of Ar, Kr, and Xe and to the 4d shell of Xe. The pseudopotentials obtained reproduce the data, and also predict accurate cross sections and phase shifts for photoelectron energies up to 100 eV. It is suggested that the pseudopotentials aptly mimic the effects of intrashell electron--electron correlations in the photoionization process. The extended Hueckel theory is applied to the nitrogen trap in GaAs and GaP. Perfect crystal band structures are computed and are shown to be in reasonable agreement with those computed with empirical pseudopotentials. Nitrogen impurity levels in GaAs and GaP are computed using an extended Hueckel cluster model. In each case the model predicts two states within the band gap, in contrast to experiment which detects one impurity state in GaP and none in GaAs. It is suggested that the choice of cluster used unrealistically concentrates states near the conduction band edge on the central atom

  19. Studies in the electronic structure of matter

    International Nuclear Information System (INIS)

    Miller, D.L.

    1979-01-01

    KLL Auger transition rates for helium are computed using simple atomic orbital wavefunctions which take into account the difference in average electron-electron repulsion of initial and final states. The results are consistent with transition rates computed by other authors using a variety of many-electron techniques. It is suggested that wavefunctions determined in the manner described provide a useful representation of the autoionizing state within the first Bohr radius. A method for extracting atomic psuedopotentials from photoelectron angular distributions is described and applied photoionization of the outermost p shells of Ar, Kr, and Xe and to the 4d shell of Xe. The pseudopotentials obtained reproduce the data, and also predict accurate cross sections and phase shifts for photoelectron energies up to 100 eV. It is suggested that the pseudopotentials aptly mimic the effects of intrashell electron-electron correlations in the photoionization process. The extended Hueckel theory is applied to the nitrogen trap in GaAs and GaP. Perfect crystal band structures are computed and are shown to be in reasonable agreement with those computed with empirical psuedopotentials. Nitrogen impurity levles in GaAs and GaP are computed using an extended Hueckel cluster model. In each case the model predicts two states within the band gap, in contrast to experiment which detects one impurity state in GaP and none in GaAs. It is suggested that the choice of cluster used unrealistically concentrates states near the conduction band edge on the central atom

  20. Study of distribution of electron density in heteropolymolybdates by method of X-ray electron spectroscopy

    International Nuclear Information System (INIS)

    Molchanov, V.N.; Kazanskij, L.P.; Torchenkova, E.A.; Spitsyn, V.I.

    1978-01-01

    X-ray electron spectra of some iso- and heteropolymolybdates relating to different structure types are investigated to study electron structure of complex polyoxyion-heteropolyanions. Binding energies of Modsub(5/2) and 01s-electrons in iso- and heteropolycompounds line are measured and their interdependence is detected. The effective charge of oxygen and molybdenum atoms in heteropolymolybdates increases with decreasing a number of external sphere cations per an oxygen atom and a number of Mo=0 multiple bonds

  1. Validation of gyrokinetic simulations with measurements of electron temperature fluctuations and density-temperature phase angles on ASDEX Upgrade

    Science.gov (United States)

    Freethy, S. J.; Görler, T.; Creely, A. J.; Conway, G. D.; Denk, S. S.; Happel, T.; Koenen, C.; Hennequin, P.; White, A. E.; ASDEX Upgrade Team

    2018-05-01

    Measurements of turbulent electron temperature fluctuation amplitudes, δTe ⊥/Te , frequency spectra, and radial correlation lengths, Lr(Te ⊥) , have been performed at ASDEX Upgrade using a newly upgraded Correlation ECE diagnostic in the range of scales k⊥scale non-linear gyrokinetic turbulence simulations of the outer core (ρtor = 0.75) of a low density, electron heated L-mode plasma, performed using the gyrokinetic simulation code, GENE. The ion and electron temperature gradients were scanned within uncertainties. It is found that gyrokinetic simulations are able to match simultaneously the electron and ion heat flux at this radius within the experimental uncertainties. The simulations were performed based on a reference discharge for which δTe ⊥/Te measurements were available, and Lr(Te ⊥) and αnT were then predicted using synthetic diagnostics prior to measurements in a repeat discharge. While temperature fluctuation amplitudes are overestimated by >50% for all simulations within the sensitivity scans performed, good quantitative agreement is found for Lr(Te ⊥) and αnT. A validation metric is used to quantify the level of agreement of individual simulations with experimental measurements, and the best agreement is found close to the experimental gradient values.

  2. Electron Tunneling in Lithium Ammonia Solutions Probed by Frequency-Dependent Electron-Spin Relaxation Studies

    Science.gov (United States)

    Maeda, Kiminori; Lodge, Matthew T.J.; Harmer, Jeffrey; Freed, Jack H.; Edwards, Peter P.

    2012-01-01

    Electron transfer or quantum tunneling dynamics for excess or solvated electrons in dilute lithium-ammonia solutions have been studied by pulse electron paramagnetic resonance (EPR) spectroscopy at both X- (9.7 GHz) and W-band (94 GHz) frequencies. The electron spin-lattice (T1) and spin-spin (T2) relaxation data indicate an extremely fast transfer or quantum tunneling rate of the solvated electron in these solutions which serves to modulate the hyperfine (Fermi-contact) interaction with nitrogen nuclei in the solvation shells of ammonia molecules surrounding the localized, solvated electron. The donor and acceptor states of the solvated electron in these solutions are the initial and final electron solvation sites found before, and after, the transfer or tunneling process. To interpret and model our electron spin relaxation data from the two observation EPR frequencies requires a consideration of a multi-exponential correlation function. The electron transfer or tunneling process that we monitor through the correlation time of the nitrogen Fermi-contact interaction has a time scale of (1–10)×10−12 s over a temperature range 230–290K in our most dilute solution of lithium in ammonia. Two types of electron-solvent interaction mechanisms are proposed to account for our experimental findings. The dominant electron spin relaxation mechanism results from an electron tunneling process characterized by a variable donor-acceptor distance or range (consistent with such a rapidly fluctuating liquid structure) in which the solvent shell that ultimately accepts the transferring electron is formed from random, thermal fluctuations of the liquid structure in, and around, a natural hole or Bjerrum-like defect vacancy in the liquid. Following transfer and capture of the tunneling electron, further solvent-cage relaxation with a timescale of ca. 10−13 s results in a minor contribution to the electron spin relaxation times. This investigation illustrates the great potential

  3. Electron tunneling in lithium-ammonia solutions probed by frequency-dependent electron spin relaxation studies.

    Science.gov (United States)

    Maeda, Kiminori; Lodge, Matthew T J; Harmer, Jeffrey; Freed, Jack H; Edwards, Peter P

    2012-06-06

    Electron transfer or quantum tunneling dynamics for excess or solvated electrons in dilute lithium-ammonia solutions have been studied by pulse electron paramagnetic resonance (EPR) spectroscopy at both X- (9.7 GHz) and W-band (94 GHz) frequencies. The electron spin-lattice (T(1)) and spin-spin (T(2)) relaxation data indicate an extremely fast transfer or quantum tunneling rate of the solvated electron in these solutions which serves to modulate the hyperfine (Fermi-contact) interaction with nitrogen nuclei in the solvation shells of ammonia molecules surrounding the localized, solvated electron. The donor and acceptor states of the solvated electron in these solutions are the initial and final electron solvation sites found before, and after, the transfer or tunneling process. To interpret and model our electron spin relaxation data from the two observation EPR frequencies requires a consideration of a multiexponential correlation function. The electron transfer or tunneling process that we monitor through the correlation time of the nitrogen Fermi-contact interaction has a time scale of (1-10) × 10(-12) s over a temperature range 230-290 K in our most dilute solution of lithium in ammonia. Two types of electron-solvent interaction mechanisms are proposed to account for our experimental findings. The dominant electron spin relaxation mechanism results from an electron tunneling process characterized by a variable donor-acceptor distance or range (consistent with such a rapidly fluctuating liquid structure) in which the solvent shell that ultimately accepts the transferring electron is formed from random, thermal fluctuations of the liquid structure in, and around, a natural hole or Bjerrum-like defect vacancy in the liquid. Following transfer and capture of the tunneling electron, further solvent-cage relaxation with a time scale of ∼10(-13) s results in a minor contribution to the electron spin relaxation times. This investigation illustrates the great

  4. Validation of radioisotopic labelling techniques in gastric emptying studies

    International Nuclear Information System (INIS)

    Corinaldesi, R.; Stanghellini, V.; Raiti, C.; Calamelli, R.; Salgemini, R.; Barbara, L.; Zarabini, G.E.

    1987-01-01

    Several techniques are currently employed to label solid and liquid foods with gamma-emitting radioisotopes in order to carry out gamma-camera gastric emptying studies. The present study describes an in vitro technique for evaluating the labelling stability of some of the most commonly employed radiomarkers of both the solid and liquid phases. Technetium-99m-sulphur colloid ( 99m Tc-SC) in vivo and in vitro labelled liver of chickens and other animal species appears to be almost ideal marker of the solid phase (97% of radioactivity still bound to the solid phase after incubation in gastric juice for 90 minutes). On the contrary, 51 CrCl 3 -beef ground meat (81%) and 99m Tc-SC egg white (69%) are unsatisfactory markers of the solid phase. Likewise, 99m Tc-DTPA and 111 In-DTPA cannot be considered satisfactory fluid-phase agents, because of the high proportion of radioactivity that leaves the liquid phase to become bound to the solid phase (respectively 76% and 49% after 90 minutes of incubation). This validation technique appears to be simple, feasible and reprodicible, and can be applied in any Nuclear Medicine Department to evaluate the validity of the labelling procedures, in order to improve the accuracy of the results of radioisotopic gastric emptying studies

  5. Recent validation studies for two NRPB environmental transfer models

    International Nuclear Information System (INIS)

    Brown, J.; Simmonds, J.R.

    1991-01-01

    The National Radiological Protection Board (NRPB) developed a dynamic model for the transfer of radionuclides through terrestrial food chains some years ago. This model, now called FARMLAND, predicts both instantaneous and time integrals of concentration of radionuclides in a variety of foods. The model can be used to assess the consequences of both accidental and routine releases of radioactivity to the environment; and results can be obtained as a function of time. A number of validation studies have been carried out on FARMLAND. In these the model predictions have been compared with a variety of sets of environmental measurement data. Some of these studies will be outlined in the paper. A model to predict external radiation exposure from radioactivity deposited on different surfaces in the environment has also been developed at NRPB. This model, called EXPURT (EXPosure from Urban Radionuclide Transfer), can be used to predict radiation doses as a function of time following deposition in a variety of environments, ranging from rural to inner-city areas. This paper outlines validation studies and future extensions to be carried out on EXPURT. (12 refs., 4 figs.)

  6. Secondary mineralization in carious lesions of human dentin. Electron-probe, electron microscope, and electron diffraction studies

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, H [Tokyo Dental Coll. (Japan)

    1975-02-01

    Dentinal carious lesions having a remineralized surface layer were studied by means electron-probe microanalysis, electron microscopy, electron diffraction. As the results of electron-probe study, F, Mg, and Na were found to be distributed mainly in the remineralized surface layer and S in the decalcified region where decreases in Ca, P, and Mg concentration were usually observed. The decrease in Mg concentration always started earlier than that of Ca and P concentration. Electron microscope and electron diffraction studies revealed that apatic crystals in the remineralized surface layer were much larger than those in the intact dentin. Although they were less conspicuous, crystals in the decalcified region also were larger than those in the intact region. Dentinal tubules, occluded by many crystals, were frequently seen during the observations. Crystals in the tubules varied in morphology, showing granular, needle, rhomboid, and tabular shapes. By means of electron diffraction, the granular- or needle-shaped crystals were identified as apatite and the rhomboid-shaped crystals as whitlockite. Some of the tabular-shaped crystals appeared to be cotacalcium phosphate.

  7. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Directory of Open Access Journals (Sweden)

    Munmun Koley

    2014-10-01

    Full Text Available A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H, Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items and patient care indicators (5 items. Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791. The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlations – Pearson's r from 0.58 (95% CI: 0.52-0.65 to 0.74 (95% CI: 0.69-0.78. The patient care indicators, except item 2, showed acceptable correlations – Pearson's r from 0.40 (95% CI: 0.31-0.48 to 0.82 (95% CI: 0.78-0.85. The instrument also showed high discriminant validity (prescribing indicators P<0.0001 and patient care indicators P<0.0001. Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development.

  8. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Science.gov (United States)

    Koley, Munmun; Saha, Subhranil; Ghosh, Shubhamoy; Nag, Goutam; Kundu, Monojit; Mondal, Ramkumar; Purkait, Rajib; Patra, Supratim

    2014-01-01

    A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H), Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items) and patient care indicators (5 items). Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791). The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlations – Pearson's r from 0.58 (95% CI: 0.52-0.65) to 0.74 (95% CI: 0.69-0.78). The patient care indicators, except item 2, showed acceptable correlations – Pearson's r from 0.40 (95% CI: 0.31-0.48) to 0.82 (95% CI: 0.78-0.85). The instrument also showed high discriminant validity (prescribing indicators P < 0.0001 and patient care indicators P < 0.0001). Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development. PMID:25379474

  9. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  10. Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron-electron interactions, application to graphene

    Science.gov (United States)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-07-01

    Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron-electron (e-e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e-e interactions. This required adapting the treatment of e-e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

  11. Poor replication validity of biomedical association studies reported by newspapers.

    Science.gov (United States)

    Dumas-Mallet, Estelle; Smith, Andy; Boraud, Thomas; Gonon, François

    2017-01-01

    To investigate the replication validity of biomedical association studies covered by newspapers. We used a database of 4723 primary studies included in 306 meta-analysis articles. These studies associated a risk factor with a disease in three biomedical domains, psychiatry, neurology and four somatic diseases. They were classified into a lifestyle category (e.g. smoking) and a non-lifestyle category (e.g. genetic risk). Using the database Dow Jones Factiva, we investigated the newspaper coverage of each study. Their replication validity was assessed using a comparison with their corresponding meta-analyses. Among the 5029 articles of our database, 156 primary studies (of which 63 were lifestyle studies) and 5 meta-analysis articles were reported in 1561 newspaper articles. The percentage of covered studies and the number of newspaper articles per study strongly increased with the impact factor of the journal that published each scientific study. Newspapers almost equally covered initial (5/39 12.8%) and subsequent (58/600 9.7%) lifestyle studies. In contrast, initial non-lifestyle studies were covered more often (48/366 13.1%) than subsequent ones (45/3718 1.2%). Newspapers never covered initial studies reporting null findings and rarely reported subsequent null observations. Only 48.7% of the 156 studies reported by newspapers were confirmed by the corresponding meta-analyses. Initial non-lifestyle studies were less often confirmed (16/48) than subsequent ones (29/45) and than lifestyle studies (31/63). Psychiatric studies covered by newspapers were less often confirmed (10/38) than the neurological (26/41) or somatic (40/77) ones. This is correlated to an even larger coverage of initial studies in psychiatry. Whereas 234 newspaper articles covered the 35 initial studies that were later disconfirmed, only four press articles covered a subsequent null finding and mentioned the refutation of an initial claim. Journalists preferentially cover initial findings

  12. Poor replication validity of biomedical association studies reported by newspapers.

    Directory of Open Access Journals (Sweden)

    Estelle Dumas-Mallet

    Full Text Available To investigate the replication validity of biomedical association studies covered by newspapers.We used a database of 4723 primary studies included in 306 meta-analysis articles. These studies associated a risk factor with a disease in three biomedical domains, psychiatry, neurology and four somatic diseases. They were classified into a lifestyle category (e.g. smoking and a non-lifestyle category (e.g. genetic risk. Using the database Dow Jones Factiva, we investigated the newspaper coverage of each study. Their replication validity was assessed using a comparison with their corresponding meta-analyses.Among the 5029 articles of our database, 156 primary studies (of which 63 were lifestyle studies and 5 meta-analysis articles were reported in 1561 newspaper articles. The percentage of covered studies and the number of newspaper articles per study strongly increased with the impact factor of the journal that published each scientific study. Newspapers almost equally covered initial (5/39 12.8% and subsequent (58/600 9.7% lifestyle studies. In contrast, initial non-lifestyle studies were covered more often (48/366 13.1% than subsequent ones (45/3718 1.2%. Newspapers never covered initial studies reporting null findings and rarely reported subsequent null observations. Only 48.7% of the 156 studies reported by newspapers were confirmed by the corresponding meta-analyses. Initial non-lifestyle studies were less often confirmed (16/48 than subsequent ones (29/45 and than lifestyle studies (31/63. Psychiatric studies covered by newspapers were less often confirmed (10/38 than the neurological (26/41 or somatic (40/77 ones. This is correlated to an even larger coverage of initial studies in psychiatry. Whereas 234 newspaper articles covered the 35 initial studies that were later disconfirmed, only four press articles covered a subsequent null finding and mentioned the refutation of an initial claim.Journalists preferentially cover initial findings

  13. Poor replication validity of biomedical association studies reported by newspapers

    Science.gov (United States)

    Smith, Andy; Boraud, Thomas; Gonon, François

    2017-01-01

    Objective To investigate the replication validity of biomedical association studies covered by newspapers. Methods We used a database of 4723 primary studies included in 306 meta-analysis articles. These studies associated a risk factor with a disease in three biomedical domains, psychiatry, neurology and four somatic diseases. They were classified into a lifestyle category (e.g. smoking) and a non-lifestyle category (e.g. genetic risk). Using the database Dow Jones Factiva, we investigated the newspaper coverage of each study. Their replication validity was assessed using a comparison with their corresponding meta-analyses. Results Among the 5029 articles of our database, 156 primary studies (of which 63 were lifestyle studies) and 5 meta-analysis articles were reported in 1561 newspaper articles. The percentage of covered studies and the number of newspaper articles per study strongly increased with the impact factor of the journal that published each scientific study. Newspapers almost equally covered initial (5/39 12.8%) and subsequent (58/600 9.7%) lifestyle studies. In contrast, initial non-lifestyle studies were covered more often (48/366 13.1%) than subsequent ones (45/3718 1.2%). Newspapers never covered initial studies reporting null findings and rarely reported subsequent null observations. Only 48.7% of the 156 studies reported by newspapers were confirmed by the corresponding meta-analyses. Initial non-lifestyle studies were less often confirmed (16/48) than subsequent ones (29/45) and than lifestyle studies (31/63). Psychiatric studies covered by newspapers were less often confirmed (10/38) than the neurological (26/41) or somatic (40/77) ones. This is correlated to an even larger coverage of initial studies in psychiatry. Whereas 234 newspaper articles covered the 35 initial studies that were later disconfirmed, only four press articles covered a subsequent null finding and mentioned the refutation of an initial claim. Conclusion Journalists

  14. Feasability Study of Electronic Load Sensing Concept

    DEFF Research Database (Denmark)

    Hansen, Michael Rygaard; Andersen, Torben O.; Pedersen, Henrik C.

    2006-01-01

    to traditional LS-systems, in terms of better control and system utilization possibilities, combined with the increased acceptance and use of electronic sensors in mobile hydraulic machinery. The current work is to evaluate the suitability of an ELS concepts applied to a Sauer Danfoss Series 45 H-frame open...... circuit axial piston pump. Emphasis is on performance robustness with respect to both variations in internal physical parameters of the pump as well as the type of application dependant load that the pump is expected to drive.The research reflect mechatronics as an integrated design process, while...... a synergistic combination of mechanical engineering, electronic engineering, and control engineering are needed in order to get a successful ELS design....

  15. Studies in the electronic structure of matter

    International Nuclear Information System (INIS)

    Swarts, C.A.

    1979-01-01

    The results of various theories for the angular distribution of electrons photoemitted from the outermost p-shell of rare gas atoms are compared. The theories compared are the local density theories of Slater (X/sub α/) and of Hohenberg, Kohn and Sham, the pseudopotential method, Hartree-Fock theory as evaluated by Kennedy and Manson, and Amusia's random phase approximation with exchange (RPAE). Extended Huekel theory is applied to GaAs, GaP, and to the nitrogen isoelectronic trap in GaAs and GaP. The computer perfect crystal band structures are found to be in reasonable agreement with those computed with empirical pseudopotentials. Nitrogen impurity levels in GaAs and GaP are calculated using a cluster model. By means of model calculations for an independent electron metal, exact lineshapes are obtained for the photon absorption, emission and photoemission spectra of deep core states. 97 references

  16. Design and validation of an accelerator for an ultracold electron source

    Directory of Open Access Journals (Sweden)

    G. Taban

    2008-05-01

    Full Text Available We describe here a specially designed accelerator structure and a pulsed power supply that are essential parts of a high brightness cold atoms-based electron source. The accelerator structure allows a magneto-optical atom trap to be operated inside of it, and also transmits subnanosecond electric field pulses. The power supply produces high voltage pulses up to 30 kV, with a rise time of up to 30 ns. The resulting electric field inside the structure is characterized with an electro-optic measurement and with an ion time-of-flight experiment. Simulations predict that 100 fC electron bunches, generated from trapped atoms inside the structure, reach an emittance of 0.04 mm mrad and a bunch length of 80 ps.

  17. Parametric validations of analytical lifetime estimates for radiation belt electron diffusion by whistler waves

    Directory of Open Access Journals (Sweden)

    A. V. Artemyev

    2013-04-01

    Full Text Available The lifetimes of electrons trapped in Earth's radiation belts can be calculated from quasi-linear pitch-angle diffusion by whistler-mode waves, provided that their frequency spectrum is broad enough and/or their average amplitude is not too large. Extensive comparisons between improved analytical lifetime estimates and full numerical calculations have been performed in a broad parameter range representative of a large part of the magnetosphere from L ~ 2 to 6. The effects of observed very oblique whistler waves are taken into account in both numerical and analytical calculations. Analytical lifetimes (and pitch-angle diffusion coefficients are found to be in good agreement with full numerical calculations based on CRRES and Cluster hiss and lightning-generated wave measurements inside the plasmasphere and Cluster lower-band chorus waves measurements in the outer belt for electron energies ranging from 100 keV to 5 MeV. Comparisons with lifetimes recently obtained from electron flux measurements on SAMPEX, SCATHA, SAC-C and DEMETER also show reasonable agreement.

  18. Electronics: Mott Transistor: Fundamental Studies and Device Operation Mechanisms

    Science.gov (United States)

    2016-03-21

    display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. Harvard University Office for Sponsored Programs...including journal references , in the following categories: (b) Papers published in non-peer-reviewed journals (N/A for none) 03/21/2016 03/21/2016 03...limited kinetics of electron doping in correlated oxides, Applied Physics Letters (07 2015) TOTAL: 1 Books Number of Manuscripts: Patents Submitted

  19. Readout electronics validation and target detector assessment for the Neutrinos Angra experiment

    International Nuclear Information System (INIS)

    Alvarenga, T.A.; Anjos, J.C.; Azzi, G.; Cerqueira, A.S.; Chimenti, P.; Costa, J.A.; Dornelas, T.I.; Farias, P.C.M.A.; Guedes, G.P.; Gonzalez, L.F.G.; Kemp, E.; Lima, H.P.; Machado, R.; Nóbrega, R.A.; Pepe, I.M.; Ribeiro, D.B.S.; Simas Filho, E.F.; Valdiviesso, G.A.; Wagner, S.

    2016-01-01

    A compact surface detector designed to identify the inverse beta decay interaction produced by anti-neutrinos coming from near operating nuclear reactors is being developed by the Neutrinos Angra Collaboration. In this document we describe and test the detector and its readout system by means of cosmic rays acquisition. In this measurement campaign, the target detector has been equipped with 16 8-in PMTs and two scintillator paddles have been used to trigger cosmic ray events. The achieved results disclosed the main operational characteristics of the Neutrinos Angra system and have been used to assess the detector and to validate its readout system.

  20. The theoretical study of the optical klystron free electron laser

    International Nuclear Information System (INIS)

    Yang Zhenhua

    2001-01-01

    The work of the theoretical study and numerical simulation of optical klystron free electron laser is supported by National 863 Research Development Program and National Science Foundation of China. The object of studying UV band free electron laser (FEL) is to understand the physical law of optical klystron FEL and to gain experience for design. A three-dimensional code OPFEL are made and it is approved that the code is correct completely. The magnetic field of the optical klystron, the energy modulation of the electron beam, the density modulation of the electron beam, spontaneous emission of the electron beam in optical klystron, the harmonic super-radiation of the electron beam, and the effects of the undulator magnetic field error on modulation of the electron beam energy are simulated. These results are useful for the future experiments

  1. Transmission Electron Microscopy Studies of Electron-Selective Titanium Oxide Contacts in Silicon Solar Cells

    KAUST Repository

    Ali, Haider; Yang, Xinbo; Weber, Klaus; Schoenfeld, Winston V.; Davis, Kristopher O.

    2017-01-01

    In this study, the cross-section of electron-selective titanium oxide (TiO2) contacts for n-type crystalline silicon solar cells were investigated by transmission electron microscopy. It was revealed that the excellent cell efficiency of 21

  2. Library usage patterns in the electronic information environment. Electronic journals, Use studies, Libraries, Medical libraries

    Directory of Open Access Journals (Sweden)

    B. Franklin

    2004-01-01

    Full Text Available This paper examines the methodology and results from Web-based surveys of more than 15,000 networked electronic services users in the United States between July 1998 and June 2003 at four academic health sciences libraries and two large main campus libraries serving a variety of disciplines. A statistically valid methodology for administering simultaneous Web-based and print-based surveys using the random moments sampling technique is discussed and implemented. Results from the Web-based surveys showed that at the four academic health sciences libraries, there were approximately four remote networked electronic services users for each in-house user. This ratio was even higher for faculty, staff, and research fellows at the academic health sciences libraries, where more than five remote users for each in-house user were recorded. At the two main libraries, there were approximately 1.3 remote users for each in-house user of electronic information. Sponsored research (grant funded research accounted for approximately 32% of the networked electronic services activity at the health sciences libraries and 16% at the main campus libraries. Sponsored researchers at the health sciences libraries appeared to use networked electronic services most intensively from on-campus, but not from in the library. The purpose of use for networked electronic resources by patrons within the library is different from the purpose of use of those resources by patrons using the resources remotely. The implications of these results on how librarians reach decisions about networked electronic resources and services are discussed.

  3. Chlorine-36 validation Study at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    J. Paces

    2006-01-01

    The amount, spatial distribution, and velocity of water percolating through the unsaturated zone (UZ) at Yucca Mountain, Nevada, are important issues for assessing the performance of the proposed deep geologic repository for spent nuclear fuel and high-level radioactive waste. To help characterize the nature and history of UZ flow, isotopic studies were initiated in 1995, using rock samples collected from the Miocene ash-flow tuffs in the Exploratory Studies Facility (ESF), an 8-km-long tunnel constructed along the north-south extent of the repository block, and the Enhanced Characterization of the Repository Block (ECRB) Cross Drift, a 2.5-km-long tunnel constructed across the repository block (Figure 1-1, Sources: Modified from DOE 2002 [Figure 1-14] and USBR 1996). Scientists from Los Alamos National Laboratory (LANL) analyzed for chlorine-36 ( 36 Cl) in salts leached from whole-rock samples collected from tunnel walls and subsurface boreholes, and scientists from the U.S. Geological Survey (USGS) analyzed for isotopes of oxygen, carbon, uranium, lead, thorium, and strontium in secondary minerals collected from subsurface fractures and lithophysal cavities. Elevated values for ratios of 36 Cl to total chloride ( 36 Cl/CL) at the level of the proposed repository indicated that small amounts of water carrying bomb-pulse 36 Cl (i.e., 36 Cl/Cl ratios greater than 1250 x 10 -15 resulting from 36 Cl produced by atmospheric testing of nuclear devices during the 1950s and early 1960s) had percolated through welded and nonwelded tuffs to depths of 200 to 300 meters (m) beneath the land surface over the past 50 years. Because of the implications of short travel times to the performance of the proposed repository, the U.S. Department of Energy (DOE)/Office of Civilian Radioactive Waste Management (OCRWM), Office of Repository Development (ORD), decided to verify the 36 Cl/Cl data with an independent validation study. DOE asked the USGS to design and implement a validation

  4. A Validity Study of the MWEP Scale in Hong Kong

    Directory of Open Access Journals (Sweden)

    Tsun-Lok Kwong

    2017-10-01

    Full Text Available This article examines the validity of the Multidimensional Work Ethic Profile, MWEP, in the Hong Kong setting. Purposive quota sampling is adopted to solicit data from a total of 140 respondents with equal gender distribution across seven age groups in Hong Kong. Factor analysis reveals that similarity exists between factor loadings in original MWEP model of Miller, Woehr, and Hudspeth (2002 and the model in the current study with Hong Kong samples. However, the MWEP items in the current study does not map exactly into the seven dimensions proposed by Miller, Woehr, and Hudspeth. The leisure and the morality/ethics dimensions match with the original scale respectively with good and poor reliabilities, but the hard work and wasted time dimensions have intertwined and appeared to be inseparable.

  5. Electron scattering studies of nitrogen dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Dhanoj; Naghma, Rahla [Department of Applied Physics, Indian School of Mines, Dhanbad 826004, Jharkhand (India); Vinodkumar, Minaxi [V. P. and R. P. T. P. Science College, Vallabh Vidyanagar 388120, Gujarat (India); Antony, Bobby, E-mail: bka.ism@gmail.com [Department of Applied Physics, Indian School of Mines, Dhanbad 826004, Jharkhand (India)

    2013-12-15

    Highlights: •Two quantum mechanical models used to find TCS for e-NO{sub 2} from 0.5 to 2000 eV. •R-matrix method at low energies (<15 eV) and SCOP at high energies (16 to 2000 eV). •Besides CS, R-matrix method predicts resonances and possibility of DEA formation. •SCOP formalism is used to find total inelastic and elastic CS at high energies. •Resonances detected at 1.33, 3 and 8.41 eV is associated with O{sup −} anion formation by DEA. -- Abstract: Present work reports total cross sections for e-NO{sub 2} scattering over an extensive range of impact energy from 0.5 eV to 2000 eV, through a composite formalism. The ab initio R-matrix method is employed for calculations up to 15 eV while the spherical complex optical potential formalism is used beyond that energy. The electronic excitation cross sections are computed from ground state X{sup 2}A{sub 1} to seven electronically allowed excited states {sup 2}B{sub 1}, {sup 2}B{sub 2}, {sup 2}A{sub 2}, {sup 4}A{sub 2}, {sup 4}B{sub 2}, {sup 4}A{sub 1}, {sup 4}A{sub 1} and {sup 4}B{sub 1}. The eigenphase diagrams presented here reproduces the resonances identified earlier. The structures detected at 1.33, 3 and 8.41 eV can be associated with the observed O{sup −} anion formation through dissociative electron attachment process.

  6. Validation study of core analysis methods for full MOX BWR

    International Nuclear Information System (INIS)

    2013-01-01

    JNES has been developing a technical database used in reviewing validation of core analysis methods of LWRs in the coming occasions: (1) confirming the core safety parameters of the initial core (one-third MOX core) through a full MOX core in Oma Nuclear Power Plant, which is under the construction, (2) licensing high-burnup MOX cores in the future and (3) reviewing topical reports on core analysis codes for safety design and evaluation. Based on the technical database, JNES will issue a guide of reviewing the core analysis methods used for safety design and evaluation of LWRs. The database will be also used for validation and improving of core analysis codes developed by JNES. JNES has progressed with the projects: (1) improving a Doppler reactivity analysis model in a Monte Carlo calculation code MVP, (2) sensitivity study of nuclear cross section date on reactivity calculation of experimental cores composed of UO 2 and MOX fuel rods, (3) analysis of isotopic composition data for UO 2 and MOX fuels and (4) the guide of reviewing the core analysis codes and others. (author)

  7. Validation study of core analysis methods for full MOX BWR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    JNES has been developing a technical database used in reviewing validation of core analysis methods of LWRs in the coming occasions: (1) confirming the core safety parameters of the initial core (one-third MOX core) through a full MOX core in Oma Nuclear Power Plant, which is under the construction, (2) licensing high-burnup MOX cores in the future and (3) reviewing topical reports on core analysis codes for safety design and evaluation. Based on the technical database, JNES will issue a guide of reviewing the core analysis methods used for safety design and evaluation of LWRs. The database will be also used for validation and improving of core analysis codes developed by JNES. JNES has progressed with the projects: (1) improving a Doppler reactivity analysis model in a Monte Carlo calculation code MVP, (2) sensitivity study of nuclear cross section date on reactivity calculation of experimental cores composed of UO{sub 2} and MOX fuel rods, (3) analysis of isotopic composition data for UO{sub 2} and MOX fuels and (4) the guide of reviewing the core analysis codes and others. (author)

  8. Electron microscope studies on nuclear track filters

    International Nuclear Information System (INIS)

    Roell, I.; Siegmon, W.

    1982-01-01

    Nuclear track filters became more and more important in various fields of application. The filtration process can be described by a set of suitable parameters. For some applications it may be necessary to know the structure of the surface and the pores themselves. In most cases the etching process yields surfaces and pore geometries that are quite different from ideal planes and cylinders. In the presented work the production of different filter types will be described. The resulting surfaces and pore structures have been investigated by means of a scanning electron microscope. (author)

  9. Copenhagen Psychosocial Questionnaire - A validation study using the Job Demand-Resources model.

    Directory of Open Access Journals (Sweden)

    Hanne Berthelsen

    Full Text Available This study aims at investigating the nomological validity of the Copenhagen Psychosocial Questionnaire (COPSOQ II by using an extension of the Job Demands-Resources (JD-R model with aspects of work ability as outcome.The study design is cross-sectional. All staff working at public dental organizations in four regions of Sweden were invited to complete an electronic questionnaire (75% response rate, n = 1345. The questionnaire was based on COPSOQ II scales, the Utrecht Work Engagement scale, and the one-item Work Ability Score in combination with a proprietary item. The data was analysed by Structural Equation Modelling.This study contributed to the literature by showing that: A The scale characteristics were satisfactory and the construct validity of COPSOQ instrument could be integrated in the JD-R framework; B Job resources arising from leadership may be a driver of the two processes included in the JD-R model; and C Both the health impairment and motivational processes were associated with WA, and the results suggested that leadership may impact WA, in particularly by securing task resources.In conclusion, the nomological validity of COPSOQ was supported as the JD-R model-can be operationalized by the instrument. This may be helpful for transferral of complex survey results and work life theories to practitioners in the field.

  10. Copenhagen Psychosocial Questionnaire - A validation study using the Job Demand-Resources model.

    Science.gov (United States)

    Berthelsen, Hanne; Hakanen, Jari J; Westerlund, Hugo

    2018-01-01

    This study aims at investigating the nomological validity of the Copenhagen Psychosocial Questionnaire (COPSOQ II) by using an extension of the Job Demands-Resources (JD-R) model with aspects of work ability as outcome. The study design is cross-sectional. All staff working at public dental organizations in four regions of Sweden were invited to complete an electronic questionnaire (75% response rate, n = 1345). The questionnaire was based on COPSOQ II scales, the Utrecht Work Engagement scale, and the one-item Work Ability Score in combination with a proprietary item. The data was analysed by Structural Equation Modelling. This study contributed to the literature by showing that: A) The scale characteristics were satisfactory and the construct validity of COPSOQ instrument could be integrated in the JD-R framework; B) Job resources arising from leadership may be a driver of the two processes included in the JD-R model; and C) Both the health impairment and motivational processes were associated with WA, and the results suggested that leadership may impact WA, in particularly by securing task resources. In conclusion, the nomological validity of COPSOQ was supported as the JD-R model-can be operationalized by the instrument. This may be helpful for transferral of complex survey results and work life theories to practitioners in the field.

  11. Physical methods for studying minerals and solid materials: X-ray, electron and neutron diffraction; scanning and transmission electron microscopy; X-ray, electron and ion spectrometry

    International Nuclear Information System (INIS)

    Eberhart, J.-P.

    1976-01-01

    The following topics are discussed: theoretical aspects of radiation-matter interactions; production and measurement of radiations (X rays, electrons, neutrons); applications of radiation interactions to the study of crystalline materials. The following techniques are presented: X-ray and neutron diffraction, electron microscopy, electron diffraction, X-ray fluorescence analysis, electron probe microanalysis, surface analysis by electron emission spectrometry (ESCA and Auger electrons), scanning electron microscopy, secondary ion emission analysis [fr

  12. The UK Biobank sample handling and storage validation studies.

    Science.gov (United States)

    Peakman, Tim C; Elliott, Paul

    2008-04-01

    and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.

  13. Study of electron transmission through thin metallic films by the electron moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Babikova, Yu.F.; Vakar, O.M.; Gruzin, O.M.; Petrikin, Yu.V.

    1983-01-01

    Results of the experimental study of the transmission of conversion electrons through aluminium, iron, tin and gold films are presented. Absorption of resonance electrons of the Moessbauer nuclide 57 Fe, formed during target irradiation with γ-quanta of 57 Co source in chromium matrix has been studied. It is asserted that absorption of conversion electrons in films of different elements is similar; at that, like in the case of β-particles, the law of absorption of resonance electrons, emitted from the flat layer, is exponential For conversion electrons of the Moessbauer nuclide 57 Fe the absorption coefficient is (0.025+-0.002) cm 2 /μg, which in the case of iron absorbing film corresponds to (20.0+-1.0)x10 4 cm -1

  14. Simulation study of secondary electron images in scanning ion microscopy

    CERN Document Server

    Ohya, K

    2003-01-01

    The target atomic number, Z sub 2 , dependence of secondary electron yield is simulated by applying a Monte Carlo code for 17 species of metals bombarded by Ga ions and electrons in order to study the contrast difference between scanning ion microscopes (SIM) and scanning electron microscopes (SEM). In addition to the remarkable reversal of the Z sub 2 dependence between the Ga ion and electron bombardment, a fine structure, which is correlated to the density of the conduction band electrons in the metal, is calculated for both. The brightness changes of the secondary electron images in SIM and SEM are simulated using Au and Al surfaces adjacent to each other. The results indicate that the image contrast in SIM is much more sensitive to the material species and is clearer than that for SEM. The origin of the difference between SIM and SEM comes from the difference in the lateral distribution of secondary electrons excited within the escape depth.

  15. Contribution of scanning Auger microscopy to electron beam damage study

    International Nuclear Information System (INIS)

    Fontaine, J.M.

    1983-04-01

    Electron bombardment can produce surface modifications of the analysed sample. The electron beam effects on solid surfaces which have been discussed in the published literature can be classified into the following four categories: (1) heating and its consequent effects, (2) charge accumulation in insulators and its consequent effects, (3) electron stimulated adsorption (ESA), and (4) electron stimulated desorption and/or decomposition (ESD). In order to understand the physico-chemical processes which take place under electron irradiation in an Al-O system, we have carried out experiments in which, effects, such as heating, charging and gas contamination, were absent. Our results point out the role of an enhanced surface diffusion of oxygen during electron bombardment of an Al (111) sample. The importance of this phenomenon and the contribution of near-elastic scattering of the primary electrons (5 keV) to the increase of the oxidation degree observed on Al (111) are discussed, compared to the generally studied effects

  16. Electron gun design study for the IUCF beam cooling system

    International Nuclear Information System (INIS)

    Friesel, D.L.; Ellison, T.; Jones, W.P.

    1985-01-01

    The design of a low temperature electron beam cooling system for the Indiana University electron-cooled storage ring is in progress. The storage ring, which will accept the light ion beams from the existing k=200, multi-stage cyclotron facility, requires an electron beam variable in energy from about 7 to 275 keV. The electron beam system consists of a high perveance electron gun with Pierce geometry and a flat cathode. The gun and a 28 element accelerating column are immersed in a uniform longitudinal magnetic guide field. A computer modeling study of the system was conducted to determine electron beam density and transverse temperature variations as a function of anode region and accelerator column design parameters. Transverse electron beam temperatures (E /SUB t/ = mc 2 β 2 γ(/theta/ /SUB H/ +/theta/ /SUB v/ )) of less than a few tenths of an electron volt at a maximum current density of 0.4 A/cm 2 are desired over the full energy range. This was achieved in the calculations without the use of resonant focusing for a 2 Amp, 275 keV electron beam. Some systematics of the electron beam temperature variations with system design parameters are presented. A short discussion of the mechanical design of the proposed electron beam system is also given

  17. Monte Carlo Simulations Validation Study: Vascular Brachytherapy Beta Sources

    International Nuclear Information System (INIS)

    Orion, I.; Koren, K.

    2004-01-01

    During the last decade many versions of angioplasty irradiation treatments have been proposed. The purpose of this unique brachytherapy is to administer a sufficient radiation dose into the vein walls in order to prevent restonosis, a clinical sequel to balloon angioplasty. The most suitable sources for this vascular brachytherapy are the β - emitters such as Re-188, P-32, and Sr-90/Y-90, with a maximum energy range of up to 2.1 MeV [1,2,3]. The radioactive catheters configurations offered for these treatments can be a simple wire [4], a fluid filled balloon or a coated stent. Each source is differently positioned inside the blood vessel, and the emitted electrons ranges therefore vary. Many types of sources and configurations were studied either experimentally or with the use of the Monte Carlo calculation technique, while most of the Monte Carlo simulations were carried out using EGS4 [5] or MCNP [6]. In this study we compared the beta-source absorbed-dose versus radial-distance of two treatment configurations using MCNP and EGS4 simulations. This comparison was aimed to discover the differences between the MCNP and the EGS4 simulation code systems in intermediate energies electron transport

  18. Method validation and stability study of quercetin in topical emulsions

    Directory of Open Access Journals (Sweden)

    Rúbia Casagrande

    2009-01-01

    Full Text Available This study validated a high performance liquid chromatography (HPLC method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.

  19. World Workshop on Oral Medicine VI: an international validation study of clinical competencies for advanced training in oral medicine.

    Science.gov (United States)

    Steele, John C; Clark, Hadleigh J; Hong, Catherine H L; Jurge, Sabine; Muthukrishnan, Arvind; Kerr, A Ross; Wray, David; Prescott-Clements, Linda; Felix, David H; Sollecito, Thomas P

    2015-08-01

    To explore international consensus for the validation of clinical competencies for advanced training in Oral Medicine. An electronic survey of clinical competencies was designed. The survey was sent to and completed by identified international stakeholders during a 10-week period. To be validated, an individual competency had to achieve 90% or greater consensus to keep it in its current format. Stakeholders from 31 countries responded. High consensus agreement was achieved with 93 of 101 (92%) competencies exceeding the benchmark for agreement. Only 8 warranted further attention and were reviewed by a focus group. No additional competencies were suggested. This is the first international validated study of clinical competencies for advanced training in Oral Medicine. These validated clinical competencies could provide a model for countries developing an advanced training curriculum for Oral Medicine and also inform review of existing curricula. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Studies on electron transfer reactions of Keggin-type mixed ...

    Indian Academy of Sciences (India)

    Administrator

    (PV2) in aqueous phosphate buffer of pH 6 at ambient temperature. Electrochemical and optical studies show that the stoichiometry of the reaction is 1: 2 (NADH : HPA). EPR and optical studies show that HPA act as one electron acceptor and the products of electron transfer reactions are one elec- tron reduced heteropoly ...

  1. Electron microscope study of Sarcocystis sp

    Science.gov (United States)

    Zeve, V.H.; Price, D.L.; Herman, C.M.

    1966-01-01

    Sarcocystis sp. obtained from wild populations of grackles, Quiscalus quiscula (Linn.), were examined to clarify the effect of the parasite on the host. Electron micrographs are presented to show areas of muscle destruction adjacent to the parasite which appear to be mechanically produced by the parasite. The microtubules within the villus-like projections of the cyst suggest that their possible function is absorptive and/or conductive with regard to the production of a toxin or the conveyance of nutritive material to the developing cells. The proposed function of submembranous filaments and their relation to the conoid is discussed. Similarities in the ultrastructure to Toxoplasma and other protozoa tend to negate the relegation of Sarcocystis to the fungi and further emphasize its protozoan nature.

  2. Studies in the electronic structure of matter

    International Nuclear Information System (INIS)

    Swarts, C.A.

    1979-01-01

    Chapter I: Here the results of various theories for the angular distribution of electrons photoemitted from the outermost p-shell of rare gas atoms are compared. The theories compared are (I) the local density theories of Slater (X/sub α/) and of Hohenberg, Kohn and Sham, (II) the pseudopotential method, (III) Hartree-Fock theory as evaluated by Kennedy and Manson, and (IV) Amusia's Random Phase Approximation with Exchange (RPAE). It is shown that the local density theories, although simple, generally fail to produce reliable cross section; the more complicated Hartree-Fock method is no more reliable; the a priori RPAE method is most reliable, but tedious; and the phenomenological pseudopotential method offers a good combination of reliability and simplicity. The muffin-tin approximation, widely used in molecular and condensed matter physics, is examined and found to be adequate. Chapter II: Extended Hueckel theory is applied to GaAs, GaP and to the nitrogen isoelectronic trap in GaAs and GaP. The computed perfect crystal band structures are found to be in reasonable agreement with those computed with empirical pseudopotentials. Nitrogen impurity levels in GaAs and GaP are calculated using a cluster model. Chapter III: By means of model calculations for an independent electron metal, we obtain exact lineshapes for the photon absorption, emission and photoemission spectra of deep core states. We find in each case an X-ray edge anomaly as pedicted by Nozieres and De Dominicis. Sumrules are used as a general check on the calculations and to explain the deviations of the exact theory from the exciton theory away from threshold

  3. External Validation of the HERNIAscore: An Observational Study.

    Science.gov (United States)

    Cherla, Deepa V; Moses, Maya L; Mueck, Krislynn M; Hannon, Craig; Ko, Tien C; Kao, Lillian S; Liang, Mike K

    2017-09-01

    The HERNIAscore is a ventral incisional hernia (VIH) risk assessment tool that uses only preoperative variables and predictable intraoperative variables. The aim of this study was to validate and modify, if needed, the HERNIAscore in an external dataset. This was a retrospective observational study of all patients undergoing resection for gastrointestinal malignancy from 2011 through 2015 at a safety-net hospital. The primary end point was clinical postoperative VIH. Patients were stratified into low-risk, medium-risk, and high-risk groups based on HERNIAscore. A revised HERNIAscore was calculated with the addition of earlier abdominal operation as a categorical variable. Cox regression of incisional hernia with stratification by risk class was performed. Incidence rates of clinical VIH formation within each risk class were also calculated. Two hundred and forty-seven patents were enrolled. On Cox regression, in addition to the 3 variables of the HERNIAscore (BMI, COPD, and incision length), earlier abdominal operation was also predictive of VIH. The revised HERNIAscore demonstrated improved predictive accuracy for clinical VIH. Although the original HERNIAscore effectively stratified the risk of an incisional radiographic VIH developing, the revised HERNIAscore provided a statistically significant stratification for both clinical and radiographic VIHs in this patient cohort. We have externally validated and improved the HERNIAscore. The revised HERNIAscore uses BMI, incision length, COPD, and earlier abdominal operation to predict risk of postoperative incisional hernia. Future research should assess methods to prevent incisional hernias in moderate-to-high risk patients. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  4. RhinAsthma patient perspective: A Rasch validation study.

    Science.gov (United States)

    Molinengo, Giorgia; Baiardini, Ilaria; Braido, Fulvio; Loera, Barbara

    2018-02-01

    In daily practice, Health-Related Quality of Life (HRQoL) tools are useful for supplementing clinical data with the patient's perspective. To encourage their use by clinicians, the availability of tools that can quickly provide valid results is crucial. A new HRQoL tool has been proposed for patients with asthma and rhinitis: the RhinAsthma Patient Perspective-RAPP. The aim of this study was to evaluate the psychometric robustness of the RAPP using the Item Response Theory (IRT) approach, to evaluate the scalability of items and test whether or not patients use the items response scale correctly. 155 patients (53.5% women, mean age 39.1, range 16-76) were recruited during a multicenter study. RAPP metric properties were investigated using IRT models. Differential item functioning (DIF) was used for gender, age, and asthma control test (ACT). The RAPP adequately fitted the Rating Scale model, demonstrating the equality of the rating scale structure for all items. All statistics on items were satisfactory. The RAPP had adequate internal reliability and showed good ability to discriminate among different groups of participants. DIF analysis indicated that there were no differential item functioning issues for gender. One item showed a DIF by age and four items by ACT. The psychometric evaluation performed using IRT models demonstrated that the RAPP met all the criteria to be considered a reliable and valid method of measurement. From a clinical perspective, this will allow physicians to confidently interpret scores as good indicators of Quality of Life of patients with asthma.

  5. Development techniques and electron optical studies of high voltage, high current electron guns

    International Nuclear Information System (INIS)

    Rangarajan, L.M.; Mahadevan, S.; Ramamurthi, S.S.

    1992-01-01

    The progress of the electron gun design, limiting to axially symmetric geometries is discussed here with a view to utilise such guns for electron accelerators. The mechanical design features leading to the physical configuration of the gun with stringent tolerances are outlined. Vacuum processing is done at pressures of 1.3x10 -5 Pa. The gun employs W-filament emitter or a cathode pellet with bombarder service. A water cooled compact faraday cup is used to measure the electron current. Electron gun geometries have been studied using the computer programme. The preveance of the gun is 0.7x10 -7 A/Vsup(1.5) at 80 kV. Developmental techniques of such pulsed electron guns are described. (author). 7 refs., 5 figs

  6. Spin dynamics of electrons in strong fields studied via bremsstrahlung from a polarized electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Tashenov, Stanislav [Royal Institute of Technology, Stockholm (Sweden); Stockholm University (Sweden); Physikalisches Institut, Universitaet Heidelberg (Germany); Baeck, Torbjoern; Cederwall, Bo; Khaplanov, Anton; Schaessburger, Kai-Uwe [Royal Institute of Technology, Stockholm (Sweden); Barday, Roman; Enders, Joachim; Poltoratska, Yuliya [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Surzhykov, Andrey [Physikalisches Institut, Universitaet Heidelberg (Germany); GSI, Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2011-07-01

    Linear polarization of the photons emitted in the process of the atomic field electron bremsstrahlung has been studied at the newly developed 100 keV polarized electron source of TU Darmstadt. A correlation between the initial orientation of the electron spin and the degree and the angle of photon linear polarization has been measured for the first time. For this purpose a hard x-ray Compton polarimeter consisting of a segmented high purity germanium detector and an external passive photon scattering target have been applied. Linear polarization sensitive Compton and Rayleigh photon scattering distributions have been sampled by the segmented detector. The observed polarization correlation reveals a precession of the electron spin as it moves in the field of the nucleus. The full-relativistic calculations for the case of radiative recombination into a Rydberg series limit have been corroborated by the measurement. The results of this experiment suggest a new method for electron beam polarimetry.

  7. A Delphi Study and Initial Validation of Counselor Supervision Competencies

    Science.gov (United States)

    Neuer Colburn, Anita A.; Grothaus, Tim; Hays, Danica G.; Milliken, Tammi

    2016-01-01

    The authors addressed the lack of supervision training standards for doctoral counseling graduates by developing and validating an initial list of supervision competencies. They used content analysis, Delphi polling, and content validity methods to generate a list, vetted by 2 different panels of supervision experts, of 33 competencies grouped…

  8. The Coopersmith Self-Esteem Inventory: A Construct Validation Study.

    Science.gov (United States)

    Johnson, Brian W.

    1983-01-01

    Regression analyses indicated that the Coopersmith Self-Esteem Inventory has convergent validity with regard to the Piers-Harris Children's Self-Concept Scale and the Coopersmith Behavioral Academic Assessment Scale, has discriminant validity with regard to the Children's Social Desirability Scale, is sensitive to differences in achievement level,…

  9. Electron tomography study of isolated human centrioles.

    Science.gov (United States)

    Ibrahim, Rana; Messaoudi, Cédric; Chichon, Francisco Javier; Celati, Claude; Marco, Sergio

    2009-01-01

    Centrioles are components of the centrosome, which is present in most eukaryotic cells (from protozoa to mammals). They organize the microtubule skeleton during interphase and the mitotic spindle during cell division. In ciliate cells, centrioles form basal bodies that are involved in cellular motility. Despite their important roles in biology, the detailed structure of centrioles remains obscure. This work contributes to a more complete model of centriole structure. The authors used electron tomography of isolated centrosomes from the human lymphoblast KE37 to explore the details of subdistal appendages and centriole lumen organization in mother centrioles. Their results reveal that each of the nine subdistal appendages is composed of two halves (20 nm diameter each) fused in a 40 nm tip that extends 100 nm from where it anchors to microtubules. The centriole lumen is filled at the distal domain by a 45 nm periodic stack of rings. Each ring has a 30 nm diameter, is 15 nm thick, and appears to be tilted at 53 degrees perpendicular to the centriole axis. The rings are anchored to microtubules by arms. Based on their results, the authors propose a model of the mother centriole distal structure. Copyright 2008 Wiley-Liss, Inc.

  10. Electronic Library of Embrapa Cerrados: user study

    Directory of Open Access Journals (Sweden)

    Maria Elisabeth Salviati

    2015-09-01

    Full Text Available Introduction: This paper presents the results of research conducted with Electronic Library users – website, created in 2004 by Embrapa Cerrados, that organizes, stores, and provides full text of the technical scientific production published by the Institution. Objective: To explore the user profile and to make an accurate assessment of the website. Methodology: Data collection of demographic aspects; habits; and search features: navigation, loading time of pages, help, layout and terminology by an online survey. Analysis by SPSS software - Statistical Package for the Social Sciences. Results: The main users are students and agronomists, young people up to 30 years old, coming from the Federal District, belonging to universities and high schools wishing to update knowledge. After, appear the users of public agencies; private companies; Embrapa; agribusiness; federal government; schools; associations and non-governmental organizations; rural extension; cooperatives and syndicates. These users have no difficulties to use the service. Conclusions: The service works well, but some suggestions are useful to improve it. In addition, little demand coming from farms, ranches, rural extension services, cooperatives and syndicates indicates the need to design new products and services oriented to such public.

  11. Scanning electron microscopic studies on bone tumors

    International Nuclear Information System (INIS)

    Itoh, Motoya

    1978-01-01

    Surface morphological observations of benign and malinant bone tumors were made by the use of scanning electron microscopy. Tumor materials were obtained directly from patients of osteogenic sarcomas, chondrosarcomas, enchondromas, giant cell tumors and Paget's sarcoma. To compare with these human tumors, the following experimental materials were also observed: P 32 -induced rat osteogenic sarcomas with their pulmonary metastatic lesions, Sr 89 -induced transplantable mouse osteogenic sarcomas and osteoid tissues arising after artificial fractures in mice. One of the most outstanding findings was a lot of granular substances seen on cell surfaces and their intercellular spaces in osteoid or chondroid forming tissues. These substances were considered to do some parts in collaborating extracellular matrix formation. Protrusions on cell surface, such as mucrovilli were more or less fashioned by these granular substances. Additional experiments revealed these substances to be soluble in sodium cloride solution. Benign osteoid forming cells, such as osteoblasts and osteoblastic osteosarcoma cells had granular substances on their surfaces and their intercellular spaces. On the other hand, undifferentiated transplantable osteosarcoma which formed on osteoid or chondroid matrix had none of these granular substances. Consequently, the difference of surface morphology between osteosarcoma cells and osteoblasts was yet to be especially concluded. (author)

  12. Electron scattering studies by means of various nuclear models

    International Nuclear Information System (INIS)

    Essaniyazov, Sh.; Juraev, Sh.; Ismatov, E.I.

    2006-01-01

    Full text: Let us consider a general case of various interaction processes of electrons with nuclei. The study of the scattering o electrons of nuclei is the source of information on the structure of nuclei. At collision of fast electrons with nuclei, both elastic and inelastic scattering can be observed. Elastic scattering gives information on the sizes of nuclei, whereas the electrons inelastic scattering processes give important information on the dynamical properties of nuclei. In the first case, the characteristics of excited states, energy levels, their widths and others, and in the second case, momentum distribution of nucleons and other particles in nuclei are studied. Let us denote the momentum and the energy of the incident electron before and after the scattering as k and ε, and k' and ε', respectively. The angle between the vectors k and k' is denoted as θ. The scattering process is characterized by three parameters: k, k' and θ. However, it is convenient to introduce three other parameters instead of the indicated above. They are: energy ω ε - ε' and momentum q = k - k', transferred by electron at scattering, and the scattering angle θ. It is worth of mentioning the two reasons why the study of electron scattering is very effective tool to study the nuclear structure. First of all, the character of electron interaction with nucleus is a well-known electromagnetic interaction of electron with current and charge in nucleus. Secondly, this interaction is relatively weak (e 2 /ℎc) 2 = ω 2 is possible (since the photon mass is zero). In case of electrons, at fixed energy transfer ω various momentum transfer are possible. Therefore, at electron scattering study one can establish the dependence of the matrix elements of q, which are the Fourier-representations of the charge and current densities. Thus, it is possible to determine directly the spatial distribution of charge and current in nucleus. The inelastic scattering is accompanied by

  13. Modeling and Experimental Validation of the Electron Beam Selective Melting Process

    Directory of Open Access Journals (Sweden)

    Wentao Yan

    2017-10-01

    Full Text Available Electron beam selective melting (EBSM is a promising additive manufacturing (AM technology. The EBSM process consists of three major procedures: ① spreading a powder layer, ② preheating to slightly sinter the powder, and ③ selectively melting the powder bed. The highly transient multi-physics phenomena involved in these procedures pose a significant challenge for in situ experimental observation and measurement. To advance the understanding of the physical mechanisms in each procedure, we leverage high-fidelity modeling and post-process experiments. The models resemble the actual fabrication procedures, including ① a powder-spreading model using the discrete element method (DEM, ② a phase field (PF model of powder sintering (solid-state sintering, and ③ a powder-melting (liquid-state sintering model using the finite volume method (FVM. Comprehensive insights into all the major procedures are provided, which have rarely been reported. Preliminary simulation results (including powder particle packing within the powder bed, sintering neck formation between particles, and single-track defects agree qualitatively with experiments, demonstrating the ability to understand the mechanisms and to guide the design and optimization of the experimental setup and manufacturing process.

  14. The DQ and DQΦ electronic structure diabatization methods: Validation for general applications

    Energy Technology Data Exchange (ETDEWEB)

    Hoyer, Chad E.; Parker, Kelsey; Gagliardi, Laura, E-mail: gagliard@umn.edu, E-mail: truhlar@umn.edu; Truhlar, Donald G., E-mail: gagliard@umn.edu, E-mail: truhlar@umn.edu [Department of Chemistry, Chemical Theory Center, and Minnesota Supercomputing Institute, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455-0431 (United States)

    2016-05-21

    We recently proposed the dipole-quadrupole (DQ) method for transforming adiabatic electronic states to diabatic states by using matrix elements of the dipole and quadrupole operators, and we applied the method to 3-state diabatizations of LiH and phenol. Here we extend the method to also include the electrostatic potential, and we call the resulting method the DQΦ method, which denotes the dipole–quadrupole–electrostatic-potential diabatization method. The electrostatic potential provides extra flexibility, and the goal of the present work is to test and illustrate the robustness of the methods for producing diabatic potential energy curves that tend to the adiabatic curves away from crossings and avoided crossings and are smooth in regions of crossings and avoided crossings. We illustrate the generality of the methods by an application to LiH with four states and by two-state diabatizations of HCl, (H{sub 2}){sub 2}, O{sub 3}, and the reaction Li + HF → LiF + H. We find that—if enough states are included—the DQ method does not have a significant dependence on the parameter weighting the quadrupole moment, and a geometry-independent value of 10 a{sub 0}{sup −2} is adequate in all cases tested. We also find that the addition of the electrostatic potential improves the diabatic potentials in some cases and provides an additional property useful for increasing the generality of the method for diabatization.

  15. Theoretical Studies of TE-Wave Propagation as a Diagnostic for Electron Cloud

    International Nuclear Information System (INIS)

    Penn, Gregory E.; Vay, Jean-Luc

    2010-01-01

    The propagation of TE waves is sensitive to the presence of an electron cloud primarily through phase shifts generated by the altered dielectric function, but can also lead to polarization changes and other effects, especially in the presence of magnetic fields. These effects are studied theoretically and also through simulations using WARP. Examples are shown related to CesrTA parameters, and used to observe different regimes of operation as well as to validate estimates of the phase shift.

  16. First principles studies of electron tunneling in proteins

    Science.gov (United States)

    Hayashi, Tomoyuki; Stuchebrukhov, Alexei A.

    2014-01-01

    A first principles study of electronic tunneling along the chain of seven Fe/S clusters in respiratory complex I, a key enzyme in the respiratory electron transport chain, is described. The broken-symmetry states of the Fe/S metal clusters calculated at both DFT and semi-empirical ZINDO levels were utilized to examine both the extremely weak electronic couplings between Fe/S clusters and the tunneling pathways, which provide a detailed atomistic-level description of the charge transfer process in the protein. One-electron tunneling approximation was found to hold within a reasonable accuracy, with only a moderate induced polarization of the core electrons. The method is demonstrated to be able to calculate accurately the coupling matrix elements as small as 10−4 cm−1. A distinct signature of the wave properties of electrons is observed as quantum interferences of multiple tunneling pathways. PMID:25383312

  17. Theoretical study of lithium clusters by electronic stress tensor

    International Nuclear Information System (INIS)

    Ichikawa, Kazuhide; Nozaki, Hiroo; Komazawa, Naoya; Tachibana, Akitomo

    2012-01-01

    We study the electronic structure of small lithium clusters Li_n (n = 2 ∼ 8) using the electronic stress tensor. We find that the three eigenvalues of the electronic stress tensor of the Li clusters are negative and degenerate, just like the stress tensor of liquid. This leads us to propose that we may characterize a metallic bond in terms of the electronic stress tensor. Our proposal is that in addition to the negativity of the three eigenvalues of the electronic stress tensor, their degeneracy characterizes some aspects of the metallic nature of chemical bonding. To quantify the degree of degeneracy, we use the differential eigenvalues of the electronic stress tensor. By comparing the Li clusters and hydrocarbon molecules, we show that the sign of the largest eigenvalue and the differential eigenvalues could be useful indices to evaluate the metallicity or covalency of a chemical bond.

  18. Portuguese validation of the Internet Addiction Test: An empirical study.

    Science.gov (United States)

    Pontes, Halley M; Patrão, Ivone M; Griffiths, Mark D

    2014-06-01

    Research into Internet addiction (IA) has increased greatly over the last decade. Despite its various definitions and general lack of consensus regarding its conceptualisation amongst researchers, instruments for measuring this phenomenon have proliferated in a number of countries. There has been little research on IA in Portugal and this may be partly due to the absence of standardised measurement tools for assessing IA. This study attempted to address this issue by adapting a Portuguese version of the Internet Addiction Test (IAT) via a translation-back translation process and Confirmatory Factor Analysis in a sample of 593 Portuguese students that completed a Portuguese version of the IAT along with questions related to socio-demographic variables. The findings suggested that the IAT appears to be a valid and reliable instrument for measuring IA among Portuguese young adults as demonstrated by its satisfactory psychometric properties. However, the present findings also suggest the need to reword and update some of the IAT's items. Prevalence of IA found in the sample was 1.2% and is discussed alongside findings relating to socio-demographic correlates. Limitations and implications of the present study are also discussed. The present study calls for a reflection of the IAT while also contributing to a better understanding of the basic aspects of IA in the Portuguese community since many health practitioners are starting to realise that Internet use may pose a risk for some individuals.

  19. Contribution to the study of electron paramagnetic resonance and relaxation

    International Nuclear Information System (INIS)

    Theobald, Jean-Gerard

    1962-01-01

    This research thesis reports an experimental work which comprises the development of a very practical and very sensitive electron paramagnetic resonance spectrometer, and the use of this equipment for the study of irradiated substances and carbons. By studying electronic resonance signals by fast modulation of the magnetic field, the author studied phenomena of quick passage in electronic resonance, and showed that the study of these phenomena requires observation systems with a particularly large bandwidth. He reports the measurement of the line width of packs of spins of inhomogeneous lines by two different methods [fr

  20. Study of electron beam production by a plasma focus

    International Nuclear Information System (INIS)

    Smith, J.R.; Luo, C.M.; Rhee, M.J.; Schneider, R.F.

    1983-01-01

    A preliminary investigation of the electron beam produced by a plasma focus device using a current charged transmission line is described. Electron beam currents as high as 10 kA were measured. Interaction of the extracted beam and the filling gas was studied using open shutter photography

  1. Study of heliumlike neon using an electron beam ion trap

    International Nuclear Information System (INIS)

    Wargelin, B.J.; Kahn, S.M.; Beiersdorfer, P.

    1992-01-01

    The 2-to-1 spectra of several astrophysically abundant He-like ions are being studied using the Electron Beam Ion Trap (EBIT) at Lawrence Livermore National Laboratory. Spectra are recorded for a broad range of plasma parameters, including electron density, energy, and ionization balance. We describe the experimental equipment and procedure and present some typical data

  2. An Empirical Study of Logistics Organization, Electronic Linkage, and Performance

    Science.gov (United States)

    1993-01-01

    Anvari, M., "Electronic Data Interchange and Inventories," International Journal of Production Economics , 26, 1-3 (1992), 135-143. Baker, R. H., EDI: What...Electronic Data Interchange -- A Study of Norwegian Freight Forwarders Using EDI," International Journal of Production Economics , 24 (1991), 91-101. Henry, G

  3. Comparative study of electron conduction in azulene and naphthalene

    Indian Academy of Sciences (India)

    Wintec

    tional or electronic devices. Recent advances in experi- mental techniques have allowed ... stimulates us to study the electronic conduction in azulene molecule and to compare that with its isomer, naphthalene. ..... ernment of India, for funding and (SD) acknowledges CSIR,. Government of India, for a research fellowship.

  4. Ultrafast electron diffraction studies of optically excited thin bismuth films

    International Nuclear Information System (INIS)

    Rajkovic, Ivan

    2008-01-01

    This thesis contains work on the design and the realization of an experimental setup capable of providing sub-picosecond electron pulses for ultrafast electron diffraction experiments, and performing the study of ultrafast dynamics in bismuth after optical excitation using this setup. (orig.)

  5. Ultrafast electron diffraction studies of optically excited thin bismuth films

    Energy Technology Data Exchange (ETDEWEB)

    Rajkovic, Ivan

    2008-10-21

    This thesis contains work on the design and the realization of an experimental setup capable of providing sub-picosecond electron pulses for ultrafast electron diffraction experiments, and performing the study of ultrafast dynamics in bismuth after optical excitation using this setup. (orig.)

  6. Moral judgment reloaded: a moral dilemma validation study

    Science.gov (United States)

    Christensen, Julia F.; Flexas, Albert; Calabrese, Margareta; Gut, Nadine K.; Gomila, Antoni

    2014-01-01

    We propose a revised set of moral dilemmas for studies on moral judgment. We selected a total of 46 moral dilemmas available in the literature and fine-tuned them in terms of four conceptual factors (Personal Force, Benefit Recipient, Evitability, and Intention) and methodological aspects of the dilemma formulation (word count, expression style, question formats) that have been shown to influence moral judgment. Second, we obtained normative codings of arousal and valence for each dilemma showing that emotional arousal in response to moral dilemmas depends crucially on the factors Personal Force, Benefit Recipient, and Intentionality. Third, we validated the dilemma set confirming that people's moral judgment is sensitive to all four conceptual factors, and to their interactions. Results are discussed in the context of this field of research, outlining also the relevance of our RT effects for the Dual Process account of moral judgment. Finally, we suggest tentative theoretical avenues for future testing, particularly stressing the importance of the factor Intentionality in moral judgment. Additionally, due to the importance of cross-cultural studies in the quest for universals in human moral cognition, we provide the new set dilemmas in six languages (English, French, German, Spanish, Catalan, and Danish). The norming values provided here refer to the Spanish dilemma set. PMID:25071621

  7. Moral Judgment Reloaded: A Moral Dilemma validation study

    Directory of Open Access Journals (Sweden)

    Julia F. Christensen

    2014-07-01

    Full Text Available We propose a revised set of moral dilemmas for studies on moral judgment. We selected a total of 46 moral dilemmas available in the literature and fine-tuned them in terms of four conceptual factors (Personal Force, Benefit Recipient, Evitability and Intention and methodological aspects of the dilemma formulation (word count, expression style, question formats that have been shown to influence moral judgment. Second, we obtained normative codings of arousal and valence for each dilemma showing that emotional arousal in response to moral dilemmas depends crucially on the factors Personal Force, Benefit Recipient, and Intentionality. Third, we validated the dilemma set confirming that people's moral judgment is sensitive to all four conceptual factors, and to their interactions. Results are discussed in the context of this field of research, outlining also the relevance of our RT effects for the Dual Process account of moral judgment. Finally, we suggest tentative theoretical avenues for future testing, particularly stressing the importance of the factor Intentionality in moral judgment. Additionally, due to the importance of cross-cultural studies in the quest for universals in human moral cognition, we provide the new set dilemmas in six languages (English, French, German, Spanish, Catalan and Danish. The norming values provided here refer to the Spanish dilemma set.

  8. Identifying Primary Spontaneous Pneumothorax from Administrative Databases: A Validation Study

    Directory of Open Access Journals (Sweden)

    Eric Frechette

    2016-01-01

    Full Text Available Introduction. Primary spontaneous pneumothorax (PSP is a disorder commonly encountered in healthy young individuals. There is no differentiation between PSP and secondary pneumothorax (SP in the current version of the International Classification of Diseases (ICD-10. This complicates the conduct of epidemiological studies on the subject. Objective. To validate the accuracy of an algorithm that identifies cases of PSP from administrative databases. Methods. The charts of 150 patients who consulted the emergency room (ER with a recorded main diagnosis of pneumothorax were reviewed to define the type of pneumothorax that occurred. The corresponding hospital administrative data collected during previous hospitalizations and ER visits were processed through the proposed algorithm. The results were compared over two different age groups. Results. There were 144 cases of pneumothorax correctly coded (96%. The results obtained from the PSP algorithm demonstrated a significantly higher sensitivity (97% versus 81%, p=0.038 and positive predictive value (87% versus 46%, p<0.001 in patients under 40 years of age than in older patients. Conclusions. The proposed algorithm is adequate to identify cases of PSP from administrative databases in the age group classically associated with the disease. This makes possible its utilization in large population-based studies.

  9. Cultural Responsive Teaching Readiness Scale Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Kasım KARATAŞ

    2017-12-01

    Full Text Available The aim of this research is to develop a measurement instrument that will determine the cultural responsive teaching readiness level of teacher candidates. The study group consisted of a total of 231 candidate teachers, of which 83 were males and 148 were females, who were attending their final year of class teacher education programs at various Turkish universities during the 2016-2017 education year. In the first phase, a 33-item draft form was presented to experts to be reviewed. Based on the feedback received, revisions were made and the final scale was applied to a group of 231 candidate teachers. In the analysis of the data obtained as the result of the application, Exploratory Factor Analysis (EFA was performed. The EFA produced 21 items within a two-factor structure as, “Personal Readiness” and “Professional Readiness.” It was observed that the sub-factors were components of the “cultural responsive teaching readiness” dimension, and that the goodness of fit measures obtained as a result of the First and Second Level Confirmatory Factor Analyzes (CFA were high. In addition, reliability coefficients were found to be high as a result of reliability measurements. With the help of these findings, this study concludes that the Cultural Responsive Teaching Readiness scale is both valid and reliable.

  10. Simulation studies on stability of hot electron plasma

    International Nuclear Information System (INIS)

    Ohsawa, Yukiharu

    1985-01-01

    Stability of a hot electron plasma in an NBT(EBT)-like geometry is studied by using a 2-1/2 dimensional relativistic, electromagnetic particle code. For the low-frequency hot electron interchange mode, comparison of the simulation results with the analytical predictions of linear stability theory show fairly good agreement with the magnitude of the growth rates calculated without hot electron finite Larmor radius effects. Strong stabilizing effects by finite Larmor radius of the hot electrons are observed for short wavelength modes. As for the high-frequency hot electron interchange mode, there is a discrepancy between the simulation results and the theory. The high-frequency instability is not observed though a parameter regime is chosen in which the high-frequency hot electron interchange mode is theoretically predicted to grow. Strong cross-field diffusion in a poloidal direction of the hot electrons might explain the stability. Each particle has a magnetic drift velocity, and the speed of the magnetic drift is proportional to the kinetic energy of each particle. Hence, if the particles have high temperature, the spread of the magnetic drift velocity is large. This causes a strong cross-field diffusion of the hot electrons. In the simulation for this interchange mode, an enhanced temperature relaxation is observed between the hot and cold electrons although the theoretically predicted high frequency modes are stable. (Nogami, K.)

  11. A coincidence study between photo- and Auger electrons

    International Nuclear Information System (INIS)

    Ricz, S.; Koever, A.; Varga, D.; Molnar, J.; Aksela, S.; Jurvansuu, M.

    2000-01-01

    Complete text of publication follows. The investigation of double differential cross sections of photon induced Auger electrons provides very sensitive method for studying the rearrangement process, especially when the angular correlation between photo- and Auger electrons is also studied. Such type of measurements could reveal a new aspect in studying the electron-electron, hole-electron and photoelectron - Auger electron interactions. It enables one to separate the overlapping Auger lines belonging to different initial holes. The traditional coincidence measurement is very time consuming and causes serious calibration problems. In order to overcome these experimental difficulties a new electron-spectrometer (ESA-22) was developed in ATOMKI, Debrecen in cooperation with the Electron spectroscopy group of University of Oulu, Finland. The analyzer consists of a spherical and a cylindrical part. It is very similar to the ESA-21 analyzer. The main differences is that the focal ring can be set different diameters thus either a series of channel detectors can be used to detect the electrons at different angles or a position sensitive channel plate can be applied for simultaneous angular recording of electrons. Furthermore the outer sphere and cylinder are cut into two parts so the spectrometer is capable to analyze two independent angularly resolved electron spectra (in the 0 deg - 180 deg region) at different energy regions, simultaneously. A special electronic control and data handling electronics and software was worked out to control the analyzer. The first results were presented in. In the last year the ESA-22 electron-spectrometer was transported to the I411 beam line of MAX-II synchrotron in Lund, Sweden. The advanced properties of the spectrometer was investigated by measuring coincidences between the photoelectrons originated from the Ar L 3 subshell and the Ar Auger electrons in the 203-207 eV energy region. Fig. 1 shows the single and the coincidence spectra

  12. Extended histopathology in immunotoxicity testing: Interlaboratory validation studies

    NARCIS (Netherlands)

    Germolec, D.R.; Nyska, A.; Kashon, M.; Kuper, C.F.; Portier, C.; Kommineni, C.; Johnson, K.A.; Luster, M.I.

    2004-01-01

    There has been considerable interest in the use of expanded histopathology as a primary screen for immunotoxicity assessment. To determine the utility of a semiquantitative histopathology approach for examining specific structural and architectural changes in lymphoid tissues, a validation effort

  13. AFSC/REFM: Bomb-produced age validation study

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish age validation with bomb-produced radiocarbon (14C) requires a known-age Delta14C reference chronology spanning the era of a marine increase in bomb-produced...

  14. Laser-induced electron--ion recombination used to study enhanced spontaneous recombination during electron cooling

    International Nuclear Information System (INIS)

    Schramm, U.; Wolf, A.; Schuess ler, T.; Habs, D.; Schwalm, D.; Uwira, O.; Linkemann, J.; Mueller, A.

    1997-01-01

    Spontaneous recombination of highly charged ions with free electrons in merged velocity matched electron and ion beams has been observed in earlier experiments to occur at rates significantly higher than predicted by theoretical estimates. To study this enhanced spontaneous recombination, laser induced recombination spectra were measured both in velocity matched beams and in beams with well defined relative velocities, corresponding to relative electron-ion detuning energies ranging from 1 meV up to 6.5 meV where the spontaneous recombination enhancement was found to be strongly reduced. Based on a comparison with simplified calculations, the development of the recombination spectra for decreasing detuning energies indicates additional contributions at matched velocities which could be related to the energy distribution of electrons causing the spontaneous recombination rate enhancement

  15. Biomedical Studies with the Free Electron Laser

    Science.gov (United States)

    1989-05-15

    and Berns. Mi. W. User pitotora- 26. Kestel. D.. And Chou. T. C. Tumer -localizing components of the ptirph% rin diation therapy of cancer following... cancer , (2) laser tissue interactions for the study of atherosclerosis, (3) pulsed laser effects on the eye, (4) laser application in genetic...these studies. Please refer to the appropriate article/abstract for further detail. 1. Dye plus laser photosensitization of cancer . Significant

  16. Published diagnostic models safely excluded colorectal cancer in an independent primary care validation study

    NARCIS (Netherlands)

    Elias, Sjoerd G; Kok, Liselotte; Witteman, Ben J M; Goedhard, Jelle G; Romberg-Camps, Mariëlle J L; Muris, Jean W M; de Wit, Niek J; Moons, Karel G M

    OBJECTIVE: To validate published diagnostic models for their ability to safely reduce unnecessary endoscopy referrals in primary care patients suspected of significant colorectal disease. STUDY DESIGN AND SETTING: Following a systematic literature search, we independently validated the identified

  17. Cyber Victim and Bullying Scale: A Study of Validity and Reliability

    Science.gov (United States)

    Cetin, Bayram; Yaman, Erkan; Peker, Adem

    2011-01-01

    The purpose of this study is to develop a reliable and valid scale, which determines cyber victimization and bullying behaviors of high school students. Research group consisted of 404 students (250 male, 154 male) in Sakarya, in 2009-2010 academic years. In the study sample, mean age is 16.68. Content validity and face validity of the scale was…

  18. A Validation Study of the Impression Replica Technique.

    Science.gov (United States)

    Segerström, Sofia; Wiking-Lima de Faria, Johanna; Braian, Michael; Ameri, Arman; Ahlgren, Camilla

    2018-04-17

    To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry. © 2018 by the American College of Prosthodontists.

  19. Validation study of the Questionnaire on School Maladjustment Problems (QSMP).

    Science.gov (United States)

    de la Fuente Arias, Jesús; Peralta Sánchez, Francisco Javier; Sánchez Roda, María Dolores; Trianes Torres, María Victoria

    2012-05-01

    The aim of this study was to analyze the exploratory and confirmatory structure, as well as other psychometric properties, of the Cuestionario de Problemas de Convivencia Escolar (CPCE; in Spanish, the Questionnaire on School Maladjustment Problems [QSMP]), using a sample of Spanish adolescents. The instrument was administered to 60 secondary education teachers (53.4% females and 46.6% males) between the ages of 28 and 54 years (M= 41.2, SD= 11.5), who evaluated a total of 857 adolescent students. The first-order exploratory factor analysis identified 7 factors, explaining a total variance of 62%. A second-order factor analysis yielded three dimensions that explain 84% of the variance. A confirmatory factor analysis was subsequently performed in order to reduce the number of factors obtained in the exploratory analysis as well as the number of items. Lastly, we present the results of reliability, internal consistency, and validity indices. These results and their implications for future research and for the practice of educational guidance and intervention are discussed in the conclusions.

  20. Some recent studies of electron swarms in gases

    International Nuclear Information System (INIS)

    Tagashira, H.

    1992-01-01

    Some recent studies of electron swarms in gases under the action of an electric field are introduced. The studies include a new type of continuity equation for electrons having a form in which the partial derivative of the electron density with respect to position and to time are interchanged, a method to deduce the time-of-flight and arrival-time-spectrum swarm parameters based on a Fourier-transformed Boltzmann equation, an examination of the correspondence between experimental and theoretical electron drift velocities, and an automatic technique to deduce the electron-gas molecule collision cross section from electron drift velocity data. A method for the deduction of electron collision cross sections with gas molecules having vibrational excitation cross sections greater than the elastic momentum transfer cross section by using a gas mixture technique, an integral type of method for solution of the Boltzmann equation with salient numerical stability, a quantitative analysis of the effect of Penning ionisation, and the behaviour of electron swarms under radio frequency electric fields, are also briefly discussed. 28 refs., 3 figs

  1. Electron microscope study of irradiated beryllium oxide

    International Nuclear Information System (INIS)

    Bisson, A.A.

    1965-06-01

    The beryllium oxide is studied first by fractography, before and after irradiation, using sintered samples. The fractures are examined under different aspects. The higher density sintered samples, with transgranular fractures are the most interesting for a microscopic study. It is possible to mark the difference between the 'pores' left by the sintering process and the 'bubbles' of gases that can be produced by former thermal treatments. After irradiation, the grain boundaries are very much weakened. By annealing, it is possible to observe the evolution of the gases produced by the reaction (n, 2n) and (n. α) and gathered on the grain boundaries. The irradiated beryllium oxide is afterwards studied by transmission. For that, a simple method has been used: little chips of the crushed material are examined. Clusters of point defects produced by neutrons are thus detected in crystals irradiated at the three following doses: 6 x 10 19 , 9 x 10 19 and 2 x 10 20 n f cm -2 at a temperature below 100 deg. C. For the irradiation at 6 x 10 19 n f cm -2 , the defects are merely visible, but at 2 x l0 20 n f cm -2 the crystals an crowded with clusters and the Kikuchi lines have disappeared from the micro-diffraction diagrams. The evolution of the clusters into dislocation loops is studied by a series of annealings. The activation energy (0,37 eV) calculated from the annealing curves suggests that it must be interstitials that condense into dislocation loops. Samples irradiated at high temperatures (650, 900 and 1100 deg. C) are also studied. In those specimens the size of the loops is not the same as the equilibrium size obtained after out of pile annealing at the same temperature. Those former loops are more specifically studied and their Burgers vector is determined by micro-diffraction. (author) [fr

  2. Efficacy and External Validity of Electronic and Mobile Phone-Based Interventions Promoting Vegetable Intake in Young Adults: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Nour, Monica; Chen, Juliana; Allman-Farinelli, Margaret

    2016-04-08

    Young adults (18-35 years) remain among the lowest vegetable consumers in many western countries. The digital era offers opportunities to engage this age group in interventions in new and appealing ways. This systematic review evaluated the efficacy and external validity of electronic (eHealth) and mobile phone (mHealth) -based interventions that promote vegetable intake in young adults. We searched several electronic databases for studies published between 1990 and 2015, and 2 independent authors reviewed the quality and risk of bias of the eligible papers and extracted data for analyses. The primary outcome of interest was the change in vegetable intake postintervention. Where possible, we calculated effect sizes (Cohen d and 95% CIs) for comparison. A random effects model was applied to the data for meta-analysis. Reach and representativeness of participants, intervention implementation, and program maintenance were assessed to establish external validity. Published validation studies were consulted to determine the validity of tools used to measure intake. We applied the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system to evaluate the overall quality of the body of evidence. Of the 14 studies that met the selection criteria, we included 12 in the meta-analysis. In the meta-analysis, 7 studies found positive effects postintervention for fruit and vegetable intake, Cohen d 0.14-0.56 (pooled effect size 0.22, 95% CI 0.11-0.33, I(2)=68.5%, P=.002), and 4 recorded positive effects on vegetable intake alone, Cohen d 0.11-0.40 (pooled effect size 0.15, 95% CI 0.04-0.28, I(2)=31.4%, P=.2). These findings should be interpreted with caution due to variability in intervention design and outcome measures. With the majority of outcomes documented as a change in combined fruit and vegetable intake, it was difficult to determine intervention effects on vegetable consumption specifically. Measurement of intake was most commonly by self

  3. Studies of electron drift velocity in nitrogen and isobutane

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Pontificia Univ. Catolica de Sao Paulo (PUC/SP), SP (Brazil); Vivaldini, Tulio C.; Lima, Iara B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ridenti, Marco A.; Pascholati, Paulo R. [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Fisica. Lab. do Acelerador Linear; Fonte, Paulo; Mangiarotti, Alessio [Universidade de Coimbra (Portugal). Dept. de fisica. Lab. de Instrumentacao e Fisica Experimental de Particulas

    2009-07-01

    Full text: The electron drift velocity is one of the most important transport parameters used to describe the physical behaviour of gas discharges and the development of avalanches in gaseous detectors, mainly when temporal information is significant, as in drift chambers and in the recent Resistive Plate Chambers (RPCs). Although many filling gases, isobutane is frequently used in RPCs, due to its excellent timing properties, but at high electric fields conditions there are insufficient data available in literature. In the present work we report the preliminary results related to the dependence of the electron drift velocity for isobutane as function of the reduced electric field E/N, in the range of 100 Td up to 216 Td. There are different methods to determine electron drift velocity in a gas, and our measurements were based on the Pulsed Townsend technique, which consists of extracting electrons from a metallic cathode and accelerates them toward the anode by a uniform electric field. Once the drift distance and the transit time are known, the drift velocities can be determined. In our system, the incidence of a nitrogen laser beam (LTB MNL200-LD) liberates electron from the cathode made of aluminium (40mm diameter). By means of a high voltage supply (Bertan, 225-30), these electrons are accelerated toward the anode (made of a high resistivity glass - 2:10{sup 12}{omega} cm) and this movement produces a fast electric signal in the anode, which is digitalized in an oscilloscope (LeCroy WavePro 7000) with 1 GHz bandwidth and 10 GS/s. The values obtained were compared to that ones of a Bolsig+ simulation code. In order to validate the technique and to analyze non-uniformity effects, results for nitrogen are also presented. (author)

  4. Studies of electron drift velocity in nitrogen and isobutane

    International Nuclear Information System (INIS)

    Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B.; Vivaldini, Tulio C.; Lima, Iara B.; Ridenti, Marco A.; Pascholati, Paulo R.; Fonte, Paulo; Mangiarotti, Alessio

    2009-01-01

    Full text: The electron drift velocity is one of the most important transport parameters used to describe the physical behaviour of gas discharges and the development of avalanches in gaseous detectors, mainly when temporal information is significant, as in drift chambers and in the recent Resistive Plate Chambers (RPCs). Although many filling gases, isobutane is frequently used in RPCs, due to its excellent timing properties, but at high electric fields conditions there are insufficient data available in literature. In the present work we report the preliminary results related to the dependence of the electron drift velocity for isobutane as function of the reduced electric field E/N, in the range of 100 Td up to 216 Td. There are different methods to determine electron drift velocity in a gas, and our measurements were based on the Pulsed Townsend technique, which consists of extracting electrons from a metallic cathode and accelerates them toward the anode by a uniform electric field. Once the drift distance and the transit time are known, the drift velocities can be determined. In our system, the incidence of a nitrogen laser beam (LTB MNL200-LD) liberates electron from the cathode made of aluminium (40mm diameter). By means of a high voltage supply (Bertan, 225-30), these electrons are accelerated toward the anode (made of a high resistivity glass - 2:10 12 Ω cm) and this movement produces a fast electric signal in the anode, which is digitalized in an oscilloscope (LeCroy WavePro 7000) with 1 GHz bandwidth and 10 GS/s. The values obtained were compared to that ones of a Bolsig+ simulation code. In order to validate the technique and to analyze non-uniformity effects, results for nitrogen are also presented. (author)

  5. Electronic Freight Management Case Studies : a Summary of Results

    Science.gov (United States)

    2012-04-01

    The Electronic Freight Management (EFM) initiative is a USDOT-sponsored project that applies Web technologies that improve data and message transmissions between supply chain partners. The EFM implementation case studies contained in this document ex...

  6. A study on the Electronic SAMG Framework

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. H.; Ahn, K. I; Jin, Y. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    Since the Fukushima accident, unexpected accidents or extreme damages have become a concern. Therefore, a rapid and exact confrontation such as a computerized attempt in SAMG has been tried. To contribute to a rapid and accurate processing for a severe accident, based on the study of SAMG functional modules, the e-SAMG framework has been studied and developed. This paper describes a study on the e-SAMG framework. Through the eSAMG development, a rapid and accurate decision can be expected, and the burden of operator during a severe accident can also be reduced. In a qualitative view, eSAMG can be used to promote work skills in the field, and manage rapid work. It can also secure the efficiency and safety through an assistant system compared with severe accidents at all times. In addition, it can maximize the operator's ability through training using the eSAMG system. In a quantitative view, eSAMG can reduce the following damage through an improvement of accuracy and processing speed for a severe accident. It can also secure the PR (public relation) effect of safety and improvement of NPP perception. Moreover, it can execute systematic training against a severe accident and reduce the training cost. This system will be implemented extendedly into the entire SAMG for perfection of the complete eSAMG.

  7. Electron-ion recombination study in argon at atmospheric pressure

    International Nuclear Information System (INIS)

    Kafrouni, Hanna.

    1979-01-01

    This study deals with a wall-stabilized arc burning in argon at atmospheric pressure. A transient mode is obtained using a fast thyristor connected to the electrodes, which short-circuits the discharge. By means of two wavelengths laser interferometry and spectroscopy measurements we have determined the temporal changes of the electron density, ground state atom density and excited atom density. We have shown that, when the electric field is suppressed, the electron temperature rapidly decreases to the gas temperature before changing electron and atom densities. This phenomenon is applied to determine the gas temperature and to evaluate the role played by ionization in electron density balance. The coefficients of ambipolar diffusion, ionization and recombination and an apparent recombination coefficient are determined versus electron temperature and compared with theoretical values [fr

  8. Study of the electrons elastic scattering by atoms through pseudopotentials

    International Nuclear Information System (INIS)

    Bettega, M.H.F.

    1990-01-01

    Pseudopotentials allow an extraordinary simplification in the calculation of the electronic structure of atoms, molecules and crystals. Though they have been used extensively for electronic structure calculations, little is known of their applicability to scattering. A study of the pseudopotentials of Bachelet, Hamann and Schuter in the electron scattering by atoms was made, calculating phase-shifts and cross sections for angular momenta 1=0,1 and 2 and energy up to 5 R y. The results for the pseudopotential were compared all-electron calculations. The agreement is very good in a broad energy band. A simplification of the calculation of scattering by complex molecules where an all-electron calculation is impossible is aimed. (author)

  9. Study of relativistic electron beams generated by a foilless diode

    International Nuclear Information System (INIS)

    Jones, M.E.; Thode, L.E.

    1979-01-01

    Preliminary results of a numerical and analytical study of foilless diodes are presented. The work produced an electron emission algorithm for the particle-in-cell simulation code CCUBE. Diode performance was studied as a function of applied magnetic field strength and simple geometry changes. Annular electron beams with an energy of 5 MeV appear obtainable with densities exceeding 10 14 cm -3 . 8 figures

  10. Fast electron transport study for inertial confinement fusion

    International Nuclear Information System (INIS)

    Touati, Michael

    2015-01-01

    A new hybrid reduced model for relativistic electron beam transport in solids and dense plasmas is presented. It is based on the two first angular moments of the relativistic kinetic equation completed with the Minerbo maximum angular entropy closure. It takes into account collective effects with the self-generated electromagnetic fields as well as collisional effects with the slowing down of the electrons in collisions with plasmons, bound and free electrons and their angular scattering on both ions and electrons. This model allows for fast computations of relativistic electron beam transport while describing the kinetic distribution function evolution. Despite the loss of information concerning the angular distribution of the electron beam, the model reproduces analytical estimates in the academic case of a collimated and monoenergetic electron beam propagating through a warm and dense Hydrogen plasma and hybrid PIC simulation results in a realistic laser-generated electron beam transport in a solid target. The model is applied to the study of the emission of Kα photons in laser-solid experiments and to the generation of shock waves. (author) [fr

  11. Study the Precipitation of Radiation Belt Electrons during the Rapid Dropout Events

    Science.gov (United States)

    Tu, W.; Cunningham, G.; Li, X.; Chen, Y.

    2015-12-01

    During the main phase of storms, the relativistic electron flux in the radiation belt can drop by orders of magnitude on timescales of a few hours. Where do the electrons go? This is one of the most important outstanding questions in radiation belt studies. Radiation belt electrons can be lost either by transport across the magnetopause into interplanetary space or by precipitation into the atmosphere. In this work we first conduct a survey of the MeV electron dropouts using the Van Allen Probes data in conjunction with the low-altitude measurements of precipitating electrons by 6 NOAA/POES satellites. The dropout events are categorized into three types: precipitation-loss dominant, outward radial diffusion dominant, or with contributions from both mechanisms. The survey results suggest the relative importance of precipitation and outward radial diffusion to the fast dropouts of radiation belt electrons, and their extent in L-shell and electron energy. Then, for specific events identified as dominated by precipitation loss, we use the Drift-Diffusion model, which includes the effects of azimuthal drift and pitch angle diffusion, to simulate both the electron dropout observed by Van Allen Probes and the distributions of drift-loss-cone electrons observed by multiple low-earth-orbit satellites (6 POES and the Colorado Student Space Weather Experiment). The model quantifies the electron precipitation loss and pitch angle diffusion coefficient, Dxx, with high temporal and spatial resolution. Finally, by comparing the Dxx derived from the model with those estimated from the quasi-linear theory using wave data from Van Allen Probes and other event-specific wave models, we are able to test the validity of quasi-linear theory and seek direct evidence of the wave-particle interactions during the dropouts.

  12. Alaska North Slope Tundra Travel Model and Validation Study

    Energy Technology Data Exchange (ETDEWEB)

    Harry R. Bader; Jacynthe Guimond

    2006-03-01

    lack of variability in snow depth cover throughout the period of field experimentation. The amount of change in disturbance indicators was greater in the tundra communities of the Foothills than in those of the Coastal Plain. However the overall level of change in both community types was less than expected. In Coastal Plain communities, ground hardness and snow slab thickness were found to play an important role in change in active layer depth and soil moisture as a result of treatment. In the Foothills communities, snow cover had the most influence on active layer depth and soil moisture as a result of treatment. Once certain minimum thresholds for ground hardness, snow slab thickness, and snow depth were attained, it appeared that little or no additive effect was realized regarding increased resistance to disturbance in the tundra communities studied. DNR used the results of this modeling project to set a standard for maximum permissible disturbance of cross-country tundra travel, with the threshold set below the widely accepted standard of Low Disturbance levels (as determined by the U.S. Fish and Wildlife Service). DNR followed the modeling project with a validation study, which seemed to support the field trial conclusions and indicated that the standard set for maximum permissible disturbance exhibits a conservative bias in favor of environmental protection. Finally DNR established a quick and efficient tool for visual estimations of disturbance to determine when investment in field measurements is warranted. This Visual Assessment System (VAS) seemed to support the plot disturbance measurements taking during the modeling and validation phases of this project.

  13. Physics validation studies for muon collider detector background simulations

    International Nuclear Information System (INIS)

    Morris, Aaron Owen

    2011-01-01

    Within the broad discipline of physics, the study of the fundamental forces of nature and the most basic constituents of the universe belongs to the field of particle physics. While frequently referred to as 'high-energy physics,' or by the acronym 'HEP,' particle physics is not driven just by the quest for ever-greater energies in particle accelerators. Rather, particle physics is seen as having three distinct areas of focus: the cosmic, intensity, and energy frontiers. These three frontiers all provide different, but complementary, views of the basic building blocks of the universe. Currently, the energy frontier is the realm of hadron colliders like the Tevatron at Fermi National Accelerator Laboratory (Fermilab) or the Large Hadron Collider (LHC) at CERN. While the LHC is expected to be adequate for explorations up to 14 TeV for the next decade, the long development lead time for modern colliders necessitates research and development efforts in the present for the next generation of colliders. This paper focuses on one such next-generation machine: a muon collider. Specifically, this paper focuses on Monte Carlo simulations of beam-induced backgrounds vis-a-vis detector region contamination. Initial validation studies of a few muon collider physics background processes using G4beamline have been undertaken and results presented. While these investigations have revealed a number of hurdles to getting G4beamline up to the level of more established simulation suites, such as MARS, the close communication between us, as users, and the G4beamline developer, Tom Roberts, has allowed for rapid implementation of user-desired features. The main example of user-desired feature implementation, as it applies to this project, is Bethe-Heitler muon production. Regarding the neutron interaction issues, we continue to study the specifics of how GEANT4 implements nuclear interactions. The GEANT4 collaboration has been contacted regarding the minor discrepancies in the neutron

  14. Status of the physics validation studies using Geant4 in ATLAS

    CERN Document Server

    AUTHOR|(CDS)2108477

    2003-01-01

    The new simulation for the ATLAS detector at LHC is performed using Geant4 in a complete OO/C++ environment. In this framework the simulation of the various test beams for the different ATLAS subdetectors offers an excellent opportunity to perform physics validation studies over a wide range of physics domains: the electromagnetic processes, the individual hadronic interactions, the electromagnetic and hadronic signals in calorimeters. The simulation is implemented by paying special attention to all details of the experimental layout and by testing all possible physics processes which may be of relevance to the specific detector under test: the resulting simulation programs are often more detailed than the corresponding Geant3-based simulation suites. In this paper we present relevant features of muon, electron and pion signals in various ATLAS detectors. All remaining discrepancies between Geant4 and test-beam data are currently being addressed and progress is continuous. This work shows that Geant4 is becom...

  15. Validation and computing and performance studies for the ATLAS simulation

    CERN Document Server

    Marshall, Z; The ATLAS collaboration

    2009-01-01

    We present the validation of the ATLAS simulation software pro ject. Software development is controlled by nightly builds and several levels of automatic tests to ensure stability. Computing validation, including CPU time, memory, and disk space required per event, is benchmarked for all software releases. Several different physics processes and event types are checked to thoroughly test all aspects of the detector simulation. The robustness of the simulation software is demonstrated by the production of 500 million events on the World-wide LHC Computing Grid in the last year.

  16. Study of cerenkov radiation. Production of {gamma} rays by electron accelerators; Etude du rayonnement de freinage. Production de rayons {gamma} par des accelerateurs d'electrons

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This study is a critical comparison of the theories of Bremsstrahlung. Experimental results obtained by the production of {gamma} radiation with electron accelerators are compared to the theoretical results in order to estimate the extent to which the various theories are valid. (author) [French] Cette etude est une synthese des theories du rayonnement de freinage. Des resultats experimentaux, obtenus par la production de rayonnements {gamma} avec des accelerateurs d'electrons, sont compares aux resultats theoriques afin d'evaluer les domaines de validite des diverses theories. (auteur)

  17. Novel Automated Morphometric and Kinematic Handwriting Assessment: A Validity Study in Children with ASD and ADHD

    Science.gov (United States)

    Dirlikov, Benjamin; Younes, Laurent; Nebel, Mary Beth; Martinelli, Mary Katherine; Tiedemann, Alyssa Nicole; Koch, Carolyn A.; Fiorilli, Diana; Bastian, Amy J.; Denckla, Martha Bridge; Miller, Michael I.; Mostofsky, Stewart H.

    2017-01-01

    This study presents construct validity for a novel automated morphometric and kinematic handwriting assessment, including (1) convergent validity, establishing reliability of automated measures with traditional manual-derived Minnesota Handwriting Assessment (MHA), and (2) discriminant validity, establishing that the automated methods distinguish…

  18. Runaway electron transport studies in the HL-1M tokamak

    International Nuclear Information System (INIS)

    Zheng Yongzhen; Qi Changwei; Ding Xuantong; Li Wenzhong

    2002-01-01

    The transport of runaway electrons in a hot plasma has been studied in four experiments, which provide the runaway diffusivity D r The first experiment obtained runaway electrons using a steady state approach for values of the runaway confinement time τ r , deduced from hard X-ray bremsstrahlung spectra. In the second experiment, diffusion has been interpreted in terms of the magnetic fluctuation, from which a electron thermal diffusivity can be deduced. Runaway electro diffusion coefficient is determined by intrinsic magnetic fluctuations, rather than electrostatic fluctuations because of the high energy involved. The results presented here demonstrate the efficiency of using runaway transport techniques for determining intrinsic magnetic fluctuations

  19. Optical studies of polarized-electron-noble-gas collisions

    International Nuclear Information System (INIS)

    Gay, T.I.; Furst, J.E.; Geesmann, H.; Khakoo, M.A.; Madison, D.H.; Wijayaratna, W.M.K.P.; Bartschat, K.

    1992-01-01

    We have measured the Stoke's parameters of light emitted following impact excitation of He and Xe by transversely-polarized electrons. For He, the 2 3 S-3 3 P, 389 nm transition was studied in an effort to systematically develop a highly accurate optical electron polarimeter. The 6 3 P 2 -6 3 D 3 , 882 nm transition in Xe was used to assess the importance of spin-dependent forces on the continuum electron for this target. We attempted (and failed) to made the first optical observations of Mott scattering. (Author)

  20. Design studies on high current and grid control electron gun

    International Nuclear Information System (INIS)

    Wang Jinnan; Lu Kun; Chi Yunlong; Zhou Zusheng

    2011-01-01

    Electron gun, the source of electrons, is a kind of ultrahigh vacuum device and plays an important role in different kind of accelerators. With the irradiation accelerator demands, describes the design studies on beam optics optimization. The simulation result shows that the beam current is above 5 A with cathode voltage of 80 kV and beam emittance, gun electric field and beam waist radius meet the accelerator needs. The electron gun manufactured and installed in the test stand, the conditioning and test will be done in the near future. (authors)

  1. Study on tamper-indicating technology in electronic seals system

    International Nuclear Information System (INIS)

    Xu Xiong; Han Feng; Zuo Guangxia; Zhao Xin; Zhang Quanhu; Di Yuming

    2009-01-01

    To strengthen our national arms control verification technical storage and deepen electronic seals' research, this paper mainly introduces seals' characteristics, functions and work principle, studies on tamper-indicating technology which is a key technology in electronic seals, designs some hardware circuit such as optical transceiver, temperature detection circuit, move detection circuit, re-prized circuit and so on, also designs a software program which is used for recording the destroying or tampering events' information. Experimental results show that electronic seals system can record the destroying or tampering events' information accurately and quickly, and give corresponding tamper-indication. (authors)

  2. Role of hot electron transport in scintillators: A theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huihui [SZU-NUS Collaborative Innovation Center for Optoelectronic Science and Technology, Key Lab. of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen Univ. (China); Li, Qi [Physical Sciences Division, IBM TJ Watson Research Center, Yorktown Heights, NY (United States); Department of Computer Science, University of Illinois at Urbana-Champaign, Urbana, IL (United States); Lu, Xinfu; Williams, R.T. [Department of Physics, Wake Forest University, Winston Salem, NC (United States); Qian, Yiyang [College of Engineering and Applied Science, Nanjing University (China); Wu, Yuntao [Scintillation Materials Research Center, University of Tennessee, Knoxville, TN (United States)

    2016-10-15

    Despite recent intensive study on scintillators, several fundamental questions on scintillator properties are still unknown. In this work, we use ab-initio calculations to determine the energy dependent group velocity of the hot electrons from the electronic structures of several typical scintillators. Based on the calculated group velocities and optical phonon frequencies, a Monte-Carlo simulation of hot electron transport in scintillators is carried out to calculate the thermalization time and diffusion range in selected scintillators. Our simulations provide physical insights on a recent trend of improved proportionality and light yield from mixed halide scintillators. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Overview of the Exploration Exercise Device Validation Study Plans

    Science.gov (United States)

    DeWitt, J. K.; Swan, B. G.

    2018-01-01

    The NASA has determined that a multi-functional exercise device will be developed for use as an exercise device during exploration missions. The device will allow for full body resistance and metabolic exercise necessary to minimize physiological losses during space flight and to maintain fitness necessary to perform critical mission tasks. Prior to implementation as an exercise device on an Exploration vehicle, there will be verification and validation testing completed to determine device efficacy at providing the necessary training stimuli to achieve desired goals. Because the exploration device will be new device that has yet be specified, specific Verification and Validation (V&V) protocols have yet to be developed. Upon delivery of an exploration exercise device training unit, stakeholders throughout NASA will develop V&V plans that include ground-based testing and testing on the International Space Station (ISS). Stakeholders will develop test protocols that include success criterion for the device. Ground tests will occur at NASA Johnson Space Station prior to flight testing. The intents of the ground tests are to allow crew, spaceflight medicine, science, engineering, Astronaut Strength, Conditioning, and Reconditioning staff, and others to gain experience in the best utilization of the device. The goal is to obtain an evidence base for recommending use of the device on the ISS. The developed protocol will be created to achieve multiple objectives, including determining if the device provides an adequate training stimulus for 5th - 95th percentile males and females, allows for exercise modalities that protect functional capability, and is robust and can withstand extensive human use. Although protocols are yet to be determined, current expectations include use of the device by test subjects and current crew in order to obtain quantitative and qualitative feedback. Information obtained during the ground tests may be used to influence device modifications

  4. Polarization Studies for the eRHIC Electron Storage Ring

    Energy Technology Data Exchange (ETDEWEB)

    Gianfelice-Wendt, Eliana [Fermilab; Tepikian, S. [Brookhaven

    2018-04-01

    A hadron/lepton collider with polarized beams has been under consideration by the scientific community since some years, in the U.S. and Europe. Among the various proposals, those by JLAB and BNL with polarized electron and proton beams are currently under closer study in the U.S. Experimenters call for the simultaneous storage of electron bunches with both spin helicity. In the BNL based Ring-Ring design, electrons are stored at top energy in a ring to be accommodated in the existing RHIC tunnel. The transversely polarized electron beam is injected into the storage ring at variable energies, between 5 and 18 GeV. Polarization is brought into the longitudinal direction at the IP by a couple of spin rotators. In this paper results of first studies of the attainable beam polarization level and lifetime in the storage ring at 18 GeV are presented.

  5. Electron microscopy methods in studies of cultural heritage sites

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A. L., E-mail: a.vasiliev56@gmail.com; Kovalchuk, M. V.; Yatsishina, E. B. [National Research Centre “Kurchatov Institute” (Russian Federation)

    2016-11-15

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient “nanotechnologies”; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  6. Electron microscopy methods in studies of cultural heritage sites

    Science.gov (United States)

    Vasiliev, A. L.; Kovalchuk, M. V.; Yatsishina, E. B.

    2016-11-01

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient "nanotechnologies"; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  7. Electron microscopy methods in studies of cultural heritage sites

    International Nuclear Information System (INIS)

    Vasiliev, A. L.; Kovalchuk, M. V.; Yatsishina, E. B.

    2016-01-01

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient “nanotechnologies”; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  8. Ecological Validity in Eye-Tracking: An Empirical Study

    Science.gov (United States)

    Spinner, Patti; Gass, Susan M.; Behney, Jennifer

    2013-01-01

    Eye-trackers are becoming increasingly widespread as a tool to investigate second language (L2) acquisition. Unfortunately, clear standards for methodology--including font size, font type, and placement of interest areas--are not yet available. Although many researchers stress the need for ecological validity--that is, the simulation of natural…

  9. Studies on cleaning validation for a cream and ointment ...

    African Journals Online (AJOL)

    Validation methods included the visual inspection of the machine surface, swab sampling, microbial bioburden determination and testing the final rinse for conductivity, pH and total organic carbon (TOC) limits. Acceptance limit calculations depended on the figure tip unit (FTU). Results: No visual residue or chemical residue ...

  10. Validation of Case Finding Algorithms for Hepatocellular Cancer From Administrative Data and Electronic Health Records Using Natural Language Processing.

    Science.gov (United States)

    Sada, Yvonne; Hou, Jason; Richardson, Peter; El-Serag, Hashem; Davila, Jessica

    2016-02-01

    Accurate identification of hepatocellular cancer (HCC) cases from automated data is needed for efficient and valid quality improvement initiatives and research. We validated HCC International Classification of Diseases, 9th Revision (ICD-9) codes, and evaluated whether natural language processing by the Automated Retrieval Console (ARC) for document classification improves HCC identification. We identified a cohort of patients with ICD-9 codes for HCC during 2005-2010 from Veterans Affairs administrative data. Pathology and radiology reports were reviewed to confirm HCC. The positive predictive value (PPV), sensitivity, and specificity of ICD-9 codes were calculated. A split validation study of pathology and radiology reports was performed to develop and validate ARC algorithms. Reports were manually classified as diagnostic of HCC or not. ARC generated document classification algorithms using the Clinical Text Analysis and Knowledge Extraction System. ARC performance was compared with manual classification. PPV, sensitivity, and specificity of ARC were calculated. A total of 1138 patients with HCC were identified by ICD-9 codes. On the basis of manual review, 773 had HCC. The HCC ICD-9 code algorithm had a PPV of 0.67, sensitivity of 0.95, and specificity of 0.93. For a random subset of 619 patients, we identified 471 pathology reports for 323 patients and 943 radiology reports for 557 patients. The pathology ARC algorithm had PPV of 0.96, sensitivity of 0.96, and specificity of 0.97. The radiology ARC algorithm had PPV of 0.75, sensitivity of 0.94, and specificity of 0.68. A combined approach of ICD-9 codes and natural language processing of pathology and radiology reports improves HCC case identification in automated data.

  11. Can We Study Autonomous Driving Comfort in Moving-Base Driving Simulators? A Validation Study.

    Science.gov (United States)

    Bellem, Hanna; Klüver, Malte; Schrauf, Michael; Schöner, Hans-Peter; Hecht, Heiko; Krems, Josef F

    2017-05-01

    To lay the basis of studying autonomous driving comfort using driving simulators, we assessed the behavioral validity of two moving-base simulator configurations by contrasting them with a test-track setting. With increasing level of automation, driving comfort becomes increasingly important. Simulators provide a safe environment to study perceived comfort in autonomous driving. To date, however, no studies were conducted in relation to comfort in autonomous driving to determine the extent to which results from simulator studies can be transferred to on-road driving conditions. Participants ( N = 72) experienced six differently parameterized lane-change and deceleration maneuvers and subsequently rated the comfort of each scenario. One group of participants experienced the maneuvers on a test-track setting, whereas two other groups experienced them in one of two moving-base simulator configurations. We could demonstrate relative and absolute validity for one of the two simulator configurations. Subsequent analyses revealed that the validity of the simulator highly depends on the parameterization of the motion system. Moving-base simulation can be a useful research tool to study driving comfort in autonomous vehicles. However, our results point at a preference for subunity scaling factors for both lateral and longitudinal motion cues, which might be explained by an underestimation of speed in virtual environments. In line with previous studies, we recommend lateral- and longitudinal-motion scaling factors of approximately 50% to 60% in order to obtain valid results for both active and passive driving tasks.

  12. Social Studies Oriented Achievement Goal Scale (SOAGS: Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Melehat GEZER

    2016-12-01

    Full Text Available This study aims to develop a valid and reliable instrument for measuring students' social studies achievement goal. The research was conducted on a study group consisted of 374 middle school students studying in the central district of Diyarbakır in 2014-2015 school year fall semester. Expert opinion was consulted with regard to the scale's content and face validity. Exploratory Factor Analysis (EFA and Confirmatory Factor Analysis (CFA were performed in order to measure the scale's construct validity. As a result of EFA, a 29-item and a six-factor structure model which explains 50.82% of the total variance was obtained. The emerging factors were called as a self-approach, task-approach, other-approach, task-avoidance, other-avoidance and self-avoidance respectively. The findings acquired CFA indicated that the 29-item and six-factor structure related to social studies oriented achievement goal scale have acceptable goodness of fit indices. The scale's reliability coefficients were calculated by means of internal consistency method. As a result of reliability analysis, it was determined that the reliability coefficients were within admissible limits. The finding of the item correlation and 27% of upper and lower group comparisons demonstrated that all of the items in the scale should remain. In light of these results, it could be argued that the scale is reliable and valid instrument and can be used in order to test students' social studies achievement goals.

  13. Study of the niobium dehydrogenation process by transmission electron microscopy

    International Nuclear Information System (INIS)

    Bulhoes, I.A.M.; Akune, K.

    1983-01-01

    The evolution of the micro-structure of Nb-H, during the dehydrogenation process through thermal treatment, has been studied by Transmission Electron Microscopy. The results are used in order to interpret the variation of the line resolution of Electron Channeling Pattern (ECP) of Nb-H as a function of isochronous annealing temperature. It is concluded that the improvement of the ECP line resolution is enhanced of β hydrate in Nb. (Author) [pt

  14. Ab initio study of hot electrons in GaAs

    OpenAIRE

    Bernardi, Marco; Vigil-Fowler, Derek; Ong, Chin Shen; Neaton, Jeffrey B.; Louie, Steven G.

    2015-01-01

    Hot carrier dynamics critically impacts the performance of electronic, optoelectronic, photovoltaic, and plasmonic devices. Hot carriers lose energy over nanometer lengths and picosecond timescales and thus are challenging to study experimentally, whereas calculations of hot carrier dynamics are cumbersome and dominated by empirical approaches. In this work, we present ab initio calculations of hot electrons in gallium arsenide (GaAs) using density functional theory and many-body perturbation...

  15. Electronic structure of a striped nickelate studied by the exact exchange for correlated electrons (EECE) approach

    KAUST Repository

    Schwingenschlö gl, Udo; Schuster, Cosima B.; Fré sard, Raymond

    2009-01-01

    Motivated by a RIXS study of Wakimoto, et al.(Phys. Rev. Lett., 102 (2009) 157001) we use density functional theory to analyze the magnetic order in the nickelate La5/3Sr1/3NiO4 and the details of its crystal and electronic structure. We compare

  16. Electronic structure of a striped nickelate studied by the exact exchange for correlated electrons (EECE) approach

    KAUST Repository

    Schwingenschlögl, Udo

    2009-12-01

    Motivated by a RIXS study of Wakimoto, et al.(Phys. Rev. Lett., 102 (2009) 157001) we use density functional theory to analyze the magnetic order in the nickelate La5/3Sr1/3NiO4 and the details of its crystal and electronic structure. We compare the generalized gradient approximation to the hybrid functional approach of exact exchange for correlated electrons (EECE). In contrast to the former, the latter reproduces the insulating state of the compound and the midgap states. The EECE approach, in general, appears to be appropriate for describing stripe phases in systems with orbital degrees of freedom. Copyright © EPLA, 2009.

  17. Electron Dropout Echoes Induced by Interplanetary Shock: A Statistical Study

    Science.gov (United States)

    Liu, Z.; Zong, Q.; Hao, Y.; Zhou, X.; Ma, X.; Liu, Y.

    2017-12-01

    "Electron dropout echo" as indicated by repeated moderate dropout and recovery signatures of the flux of energetic electron in the out radiation belt region has been investigated systematically. The electron dropout and its echoes are usually found for higher energy (> 300 keV) channels fluxes, whereas the flux enhancements are obvious for lower energy electrons simultaneously after the interplanetary shock arrives at the Earth's geosynchronous orbit. 104 dropout echo events have been found from 215 interplanetary shock events from 1998 to 2007 based on LANL satellite data. In analogy to substorm injections, these 104 events could be naturally divided into two categories: dispersionless (49 events) or dispersive (55 events) according to the energy dispersion of the initial dropout. It is found that locations of dispersionless events are distributed mainly in the duskside magnetosphere. Further, the obtained locations derived from dispersive events with the time-of-flight technique of the initial dropout regions are mainly located at the duskside as well. Statistical studies have shown that the effect of shock normal, interplanetary magnetic field Bz and solar wind dynamic pressure may be insignificant to these electron dropout events. We suggest that the electric field impulse induced by the IP shock produces a more pronounced inward migration of electrons at the dusk side, resulting in the observed dusk-side moderate dropout of electron flux and its consequent echoes.

  18. The global status of freshwater fish age validation studies and a prioritization framework for future research

    Science.gov (United States)

    Pope, Kevin L.; Hamel, Martin J.; Pegg, Mark A.; Spurgeon, Jonathan J.

    2016-01-01

    Age information derived from calcified structures is commonly used to estimate recruitment, growth, and mortality for fish populations. Validation of daily or annual marks on age structures is often assumed, presumably due to a lack of general knowledge concerning the status of age validation studies. Therefore, the current status of freshwater fish age validation studies was summarized to show where additional effort is needed, and increase the accessibility of validation studies to researchers. In total, 1351 original peer-reviewed articles were reviewed from freshwater systems that studied age in fish. Periodicity and age validation studies were found for 88 freshwater species comprising 21 fish families. The number of age validation studies has increased over the last 30 years following previous calls for more research; however, few species have validated structures spanning all life stages. In addition, few fishes of conservation concern have validated ageing structures. A prioritization framework, using a combination of eight characteristics, is offered to direct future age validation studies and close the validation information gap. Additional study, using the offered prioritization framework, and increased availability of published studies that incorporate uncertainty when presenting research results dealing with age information are needed.

  19. Study of γ-irradiated lithographic polymers by electron spin resonance and electron nuclear double resonance

    International Nuclear Information System (INIS)

    Schlick, S.; Kevan, L.

    1982-01-01

    The room temperature gamma irradiation degradation of the lithographic polymers, poly(methylmethacrylate) (PMMA), poly(methyl-α-chloroacrylate) (PMCA), poly(methyl-α-fluoroacrylate) (PMFA), and poly(methylacrylonitrile) (PMCN), have been studied by electron spin resonance and electron nuclear double resonance (ENDOR) to assess their molecular degradation processes of relevance to electron beam lithography. Two classes of radicals are found, chain radicals and chain scission radicals. PMMA and PMCA mainly form chain scission radicals consistent with degradation while for PMCN the resolution is poorer, and this is only probable. PMFA forms mainly chain radicals consistent with predominant crosslinking. The total radical yield is greatest in PMCA and PMCN. ENDOR is used to assess the compactness of the radiation degradation region for PMMA and PMCA and hence the potential resolution of the resist; this appears to be about the same for these methacrylate polymers

  20. Study of optical and electronic properties of nickel from reflection electron energy loss spectra

    Science.gov (United States)

    Xu, H.; Yang, L. H.; Da, B.; Tóth, J.; Tőkési, K.; Ding, Z. J.

    2017-09-01

    We use the classical Monte Carlo transport model of electrons moving near the surface and inside solids to reproduce the measured reflection electron energy-loss spectroscopy (REELS) spectra. With the combination of the classical transport model and the Markov chain Monte Carlo (MCMC) sampling of oscillator parameters the so-called reverse Monte Carlo (RMC) method was developed, and used to obtain optical constants of Ni in this work. A systematic study of the electronic and optical properties of Ni has been performed in an energy loss range of 0-200 eV from the measured REELS spectra at primary energies of 1000 eV, 2000 eV and 3000 eV. The reliability of our method was tested by comparing our results with the previous data. Moreover, the accuracy of our optical data has been confirmed by applying oscillator strength-sum rule and perfect-screening-sum rule.

  1. Progress in Fast Ignition Studies with Electrons and Protons

    Science.gov (United States)

    MacKinnon, A. J.; Akli, K. U.; Bartal, T.; Beg, F. N.; Chawla, S.; Chen, C. D.; Chen, H.; Chen, S.; Chowdhury, E.; Fedosejevs, R.; Freeman, R. R.; Hey, D.; Higginson, D.; Key, M. H.; King, J. A.; Link, A.; Ma, T.; MacPhee, A. G.; Offermann, D.; Ovchinnikov, V.; Pasley, J.; Patel, P. K.; Ping, Y.; Schumacher, D. W.; Stephens, R. B.; Tsui, Y. Y.; Wei, M. S.; Van Woerkom, L. D.

    2009-09-01

    Isochoric heating of inertially confined fusion plasmas by laser driven MeV electrons or protons is an area of great topical interest in the inertial confinement fusion community, particularly with respect to the fast ignition (FI) concept for initiating burn in a fusion capsule. In order to investigate critical aspects needed for a FI point design, experiments were performed to study 1) laser-to-electrons or protons conversion issues and 2) laser-cone interactions including prepulse effects. A large suite of diagnostics was utilized to study these important parameters. Using cone—wire surrogate targets it is found that pre-pulse levels on medium scale lasers such as Titan at Lawrence Livermore National Laboratory produce long scale length plasmas that strongly effect coupling of the laser to FI relevant electrons inside cones. The cone wall thickness also affects coupling to the wire. Conversion efficiency to protons has also been measured and modeled as a function of target thickness, material. Conclusions from the proton and electron source experiments will be presented. Recent advances in modeling electron transport and innovative target designs for reducing igniter energy and increasing gain curves will also be discussed. In conclusion, a program of study will be presented based on understanding the fundamental physics of the electron or proton source relevant to FI.

  2. Electron cloud studies for the LHC and future proton colliders

    CERN Document Server

    Domínguez Sánchez de la Blanca, César Octavio; Zimmermann, Frank

    2014-01-01

    The Large Hadron Collider (LHC) is the world’s largest and most powerful particle collider. Its main objectives are to explore the validity of the standard model of particle physics and to look for new physics beyond it, at unprecedented collision energies and rates. A good luminosity performance is imperative to attain these goals. In the last stage of the LHC commissioning (2011-2012), the limiting factor to achieving the design bunch spacing of 25 ns has been the electron cloud effects. The electron cloud is also expected to be the most important luminosity limitation after the first Long Shut-Down of the LHC (LS1), when the machine should be operated at higher energy and with 25-ns spacing, as well as for the planned luminosity upgrade (HL-LHC) and future high energy proton colliders (HE-LHC and VHE-LHC). This thesis contributes to the understanding of the electron cloud observations during the first run of the LHC (2010-2012), presents the first beam dynamics analysis for the next generation of high en...

  3. DEVELOPING OF INDIVIDUAL INSTRUMENT PERFORMANCE ANXIETY SCALE: VALIDITY - RELIABILITY STUDY

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2014-07-01

    Full Text Available The purpose of this study is to develop a scale unique to our culture, concerning  individual instrument performance anxiety of the students  who are getting instrument training  in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students  who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a one-dimensional structure consisting of 14 items was obtained. Also, t-scores and  the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.Extended AbstractsIntroductionAnxiety is a universal phenomenon which people experience once or a few times during lives. It was accepted as concern for the future or as an unpleasant emotional experience regarding probable hitches of the events (Di Tomasso & Gosch, 2002.In general, the occasions on which negative feelings are experienced cause anxiety to arise (Baltaş and Baltaş, 2000. People also feel anxious in dangerous situations. Anxiety may lead a person to be creative, while it may have hindering characteristics. Anxiety is that an individual considers him

  4. Development of a multi-institutional cohort to facilitate cardiovascular disease biomarker validation using existing biorepository samples linked to electronic health records.

    Science.gov (United States)

    Cross, Deanna S; McCarty, Catherine A; Steinhubl, Steven R; Carey, David J; Erlich, Porat M

    2013-08-01

    Emerging biomarkers for acute myocardial infarction (AMI) may enhance conventional risk-prediction algorithms if they are informative and associated with risk independently of established predictors. In this study, we constructed a cohort for testing emerging biomarkers for AMI in managed-care populations using existing biospecimen repositories linked to electronic health records (EHR). Electronic health record-based biorepositories collected by healthcare systems can be federated to provide large, methodologically sound testing sets for biomarker validation. Subjects ages 40 to 80 years were selected from 2 existing population-based biospecimen repositories. Incident AMI status and covariates were ascertained from the EHR. An ad hoc model for AMI risk was parameterized and validated. Simulation was used to test incremental gains in performance due to the inclusion of biomarkers in this model. Gains in performance were assessed in terms of area under the receiver operating characteristic curve (ROC-AUC) and case reclassification. A total of 18 329 individuals (57% female) contributed 108 400 person-years of EHR follow-up. The crude AMI incidence was 10.8 and 5.0 per 1000 person-years among males and females, respectively. Compared with the model with risk factors alone, inclusion of a simulated biomarker yielded substantial gains in sensitivity without loss of specificity. Furthermore, a net ROC-AUC gain of 13.3% was observed, as well as correct reclassification of 9.8% of incident cases (79 of 806) that were otherwise not considered statin-indicated at baseline under the National Cholesterol Education Program Adult Treatment Panel III criteria. More research is needed to assess incremental contribution of emerging biomarkers for AMI prediction in managed-care populations. © 2013 Wiley Periodicals, Inc.

  5. Environmental education curriculum evaluation questionnaire: A reliability and validity study

    Science.gov (United States)

    Minner, Daphne Diane

    The intention of this research project was to bridge the gap between social science research and application to the environmental domain through the development of a theoretically derived instrument designed to give educators a template by which to evaluate environmental education curricula. The theoretical base for instrument development was provided by several developmental theories such as Piaget's theory of cognitive development, Developmental Systems Theory, Life-span Perspective, as well as curriculum research within the area of environmental education. This theoretical base fueled the generation of a list of components which were then translated into a questionnaire with specific questions relevant to the environmental education domain. The specific research question for this project is: Can a valid assessment instrument based largely on human development and education theory be developed that reliably discriminates high, moderate, and low quality in environmental education curricula? The types of analyses conducted to answer this question were interrater reliability (percent agreement, Cohen's Kappa coefficient, Pearson's Product-Moment correlation coefficient), test-retest reliability (percent agreement, correlation), and criterion-related validity (correlation). Face validity and content validity were also assessed through thorough reviews. Overall results indicate that 29% of the questions on the questionnaire demonstrated a high level of interrater reliability and 43% of the questions demonstrated a moderate level of interrater reliability. Seventy-one percent of the questions demonstrated a high test-retest reliability and 5% a moderate level. Fifty-five percent of the questions on the questionnaire were reliable (high or moderate) both across time and raters. Only eight questions (8%) did not show either interrater or test-retest reliability. The global overall rating of high, medium, or low quality was reliable across both coders and time, indicating

  6. Study of the hollow cathode plasma electron-gun

    International Nuclear Information System (INIS)

    Zhang Yonghui; Jiang Jinsheng; Chang Anbi

    2003-01-01

    For developing a novel high-current, long pulse width electron source, the theoretics and mechanism of the hollow cathode plasma electron-gun are analyzed in detail in this paper, the structure and the physical process of hollow cathode plasma electron-gun are also studied. This gun overcomes the limitations of most high-power microwave tubes, which employ either thermionic cathodes that produce low current-density beams because of the limitation of the space charge, or field-emission cathodes that offer high current density but provide only short pulse width because of plasma closure of the accelerating gap. In the theories studying on hollow cathode plasma electron-gun, the characteristic of the hollow-cathode discharge is introduced, the action during the forming of plasma of the stimulating electrode and the modulating anode are discussed, the movement of electrons and ions and the primary parameters are analyzed, and the formulas of the electric field, beam current density and the stabilization conditions of the beam current are also presented in this paper. The numerical simulation is carried out based on Poisson's equation, and the equations of current continuity and movement. And the optimized result is reported. On this basis, we have designed a hollow-cathode-plasma electron-gun, whose output pulse current is 2 kA, and pulse width is 1 microsecond

  7. Electron acceleration by an obliquely propagating electromagnetic wave in the regime of validity of the Fokker-Planck-Kolmogorov approach

    Science.gov (United States)

    Hizanidis, Kyriakos; Vlahos, L.; Polymilis, C.

    1989-01-01

    The relativistic motion of an ensemble of electrons in an intense monochromatic electromagnetic wave propagating obliquely in a uniform external magnetic field is studied. The problem is formulated from the viewpoint of Hamiltonian theory and the Fokker-Planck-Kolmogorov approach analyzed by Hizanidis (1989), leading to a one-dimensional diffusive acceleration along paths of constant zeroth-order generalized Hamiltonian. For values of the wave amplitude and the propagating angle inside the analytically predicted stochastic region, the numerical results suggest that the diffusion probes proceeds in stages. In the first stage, the electrons are accelerated to relatively high energies by sampling the first few overlapping resonances one by one. During that stage, the ensemble-average square deviation of the variable involved scales quadratically with time. During the second stage, they scale linearly with time. For much longer times, deviation from linear scaling slowly sets in.

  8. Validation of Internet Application: Study, Analysis and Evaluation

    OpenAIRE

    Dinesh Kumar

    2012-01-01

    Today, testing applications for Internet (web sites and other applications) is being verified using proprietary test solutions. The Internet Security became a very important and complex field of researches in our present time, especially if we apply this to the discussion of Internet protocols as basic interfaces for exchanging sensitive data over the Internet and finding appropriate and trustworthy algorithms for their validation. Test Competence Centre at Ericsson AB has expertise on tes...

  9. 100 Area excavation treatability study data validation report

    International Nuclear Information System (INIS)

    Frain, J.M.

    1994-01-01

    This report presents the results of sampling and chemical analyses at Hanford Reservation. The samples were analyzed by Thermo-Analytic Laboratories and Roy F. Weston Laboratories using US Environmental Protection Agency CLP protocols. Sample analyses included: volatile organics; semivolatile organics; inorganics; and general chemical parameters. The data from the chemical analyses were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site

  10. Study of the violation of the T and CP symmetries in the reactions {lambda}{sub b}{sup 0} {yields} {lambda}{sup 0} + a vector meson. Validation of the Front-end electronics for the PreShower detector of the LHCb experiment; Recherche de la violation des symetries CP et T dans les reactions {lambda}{sub b}{sup 0} {yields} {lambda}{sup 0} + un meson vecteur. Validation de l'architecture de lecteur des canaux du detecteur de pied de gerbe de l'experience LHCb

    Energy Technology Data Exchange (ETDEWEB)

    Conte, E

    2007-11-15

    This thesis probes the beauty baryon physics in the framework of the LHCb experiment. The present study deals with the {lambda}{sub b}{sup 0} {yields} {lambda}{sup 0}V decays where V is a vector meson such as J/{psi}({mu}{sup +}{mu}{sup -}), {phi}(K{sup +}K{sup -}), {omega}({pi}{sup +}{pi}{sup -}{pi}0) or the {rho}{sup 0} - {omega}{sup 0}({pi}{sup +}{pi}{sup -}) mixing. These processes allow to test independently the CP symmetry, which violation has not been observed yet in the baryonic sector, and the T symmetry, which experimental proofs are limited. Among the possible perspectives, a precise measurement of the {lambda}{sub b}{sup 0} lifetime could contribute to the resolution of the raising theoretical-experimental puzzle. A phenomenological model of the {lambda}{sub b}{sup 0} {yields} {lambda}{sup 0}V decays has been performed, from which branching ratios and angular distributions have been estimated. An advanced study of the reconstruction and the selection of these reactions by the LHCb apparatus shows that the channel {lambda}{sub b}{sup 0} {yields} {lambda}{sup 0}J/{psi} is the dominant channel on both statistics and purity aspects. The {lambda}{sub b}{sup 0} lifetime measure is the most imminent result; the constrains on asymmetries due to CP and T violation require several data taking years. Besides, an instrumental work has been achieved on the read-out electronics, called Front-End, of the experiment pre-shower. This contribution takes into account the validation of the prototype boards and the development of tools required by the qualification of the 100 production boards. (author)

  11. Fabrication and electronic transport studies of single nanocrystal systems

    Energy Technology Data Exchange (ETDEWEB)

    Klein, David Louis [Univ. of California, Berkeley, CA (United States). Dept. of Physics

    1997-05-01

    Semiconductor and metallic nanocrystals exhibit interesting electronic transport behavior as a result of electrostatic and quantum mechanical confinement effects. These effects can be studied to learn about the nature of electronic states in these systems. This thesis describes several techniques for the electronic study of nanocrystals. The primary focus is the development of novel methods to attach leads to prefabricated nanocrystals. This is because, while nanocrystals can be readily synthesized from a variety of materials with excellent size control, means to make electrical contact to these nanocrystals are limited. The first approach that will be described uses scanning probe microscopy to first image and then electrically probe surfaces. It is found that electronic investigations of nanocrystals by this technique are complicated by tip-sample interactions and environmental factors such as salvation and capillary forces. Next, an atomic force microscope technique for the catalytic patterning of the surface of a self assembled monolayer is described. In principle, this nano-fabrication technique can be used to create electronic devices which are based upon complex arrangements of nanocrystals. Finally, the fabrication and electrical characterization of a nanocrystal-based single electron transistor is presented. This device is fabricated using a hybrid scheme which combines electron beam lithography and wet chemistry to bind single nanocrystals in tunneling contact between closely spaced metallic leads. In these devices, both Au and CdSe nanocrystals show Coulomb blockade effects with characteristic energies of several tens of meV. Additional structure is seen the transport behavior of CdSe nanocrystals as a result of its electronic structure.

  12. Implementation of the validation testing in MPPG 5.a "Commissioning and QA of treatment planning dose calculations-megavoltage photon and electron beams".

    Science.gov (United States)

    Jacqmin, Dustin J; Bredfeldt, Jeremy S; Frigo, Sean P; Smilowitz, Jennifer B

    2017-01-01

    The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analysis tools to deliver and analyze the validation tests. This included the development of a novel, open-source software tool to compare scanning water tank measurements to 3D DICOM-RT Dose distributions. Dose calculation algorithms in both Pinnacle and Eclipse were tested with MPPG 5.a to validate the modeling of Varian TrueBeam linear accelerators. The validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (TPS). Overall, the validation testing recommended in MPPG 5.a took approximately 79 person-hours for a machine with four photon and five electron energies for a single TPS. Of the 79 person-hours, 26 person-hours required time on the machine, and the remainder involved preparation and analysis. The basic photon, electron, and heterogeneity correction tests were evaluated with the tolerances in MPPG 5.a, and the tolerances were met for all tests. The MPPG 5.a evaluation criteria were used to assess the small field and IMRT/VMAT validation tests. Both institutions found the use of MPPG 5.a to be a valuable resource during the commissioning process. The validation testing in MPPG 5.a showed the strengths and limitations of the TPS models. In addition, the data collected during the validation testing is useful for routine QA of the TPS, validation of software upgrades, and commissioning of new algorithms. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of

  13. Review article: what makes a good healthcare quality indicator? A systematic review and validation study.

    Science.gov (United States)

    Jones, Peter; Shepherd, Michael; Wells, Susan; Le Fevre, James; Ameratunga, Shanthi

    2014-04-01

    Indicators measuring aspects of performance to assess quality of care are often chosen arbitrarily. The present study aimed to determine what should be considered when selecting healthcare quality indicators, particularly focusing on the application to emergency medicine. Structured searches of electronic databases were supplemented by website searches of quality of care and benchmarking organisations, citation searches and discussions with experts. Candidate attributes of 'good' healthcare indicators were extracted independently by two authors. The validity of each attribute was independently assessed by 16 experts in quality of care and emergency medicine. Valid and reliable attributes were included in a critical appraisal tool for healthcare quality indicators, which was piloted by emergency medicine specialists. Twenty-three attributes were identified, and all were rated moderate to extremely important by an expert panel. The reliability was high: alpha = 0.98. Twelve existing tools explicitly stated a median (range) of 14 (8-17) attributes. A critical appraisal tool incorporating all the attributes was developed. This was piloted by four emergency medicine specialists who were asked to appraise and rank a set of six candidate indicators. Although using the tool took more time than implicit gestalt decision making: median (interquartile range) 190 (43-352) min versus 17.5 (3-34) min, their rankings changed after using the tool. To inform the appraisal of quality improvement indicators for emergency medicine, a comprehensive list of indicator attributes was identified, validated, developed into a tool and piloted. Although expert consensus is still required, this tool provides an explicit basis for discussions around indicator selection. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  14. Early studies of placental ultrastructure by electron microscopy

    DEFF Research Database (Denmark)

    Carter, A M; Enders, A C

    2016-01-01

    many other scientists to Washington University in St. Louis. Work on human placental ultrastructure was initiated at Cambridge and Kyoto whilst domestic animals were initially studied by Björkman in Stockholm and electron micrographs of bat placenta were published by Wimsatt of Cornell University......BACKGROUND: Transmission electron microscopy (TEM) was first applied to study placental ultrastructure in the 1950's. We review those early studies and mention the scientists that employed or encouraged the use of TEM. FINDINGS: Among the pioneers Edward W. Dempsey was a key figure who attracted...

  15. Radiology Reporting System Data Exchange With the Electronic Health Record System: A Case Study in Iran.

    Science.gov (United States)

    Ahmadi, Maryam; Ghazisaeidi, Marjan; Bashiri, Azadeh

    2015-03-18

    In order to better designing of electronic health record system in Iran, integration of health information systems based on a common language must be done to interpret and exchange this information with this system is required. This study provides a conceptual model of radiology reporting system using unified modeling language. The proposed model can solve the problem of integration this information system with the electronic health record system. By using this model and design its service based, easily connect to electronic health record in Iran and facilitate transfer radiology report data. This is a cross-sectional study that was conducted in 2013. The study population was 22 experts that working at the Imaging Center in Imam Khomeini Hospital in Tehran and the sample was accorded with the community. Research tool was a questionnaire that prepared by the researcher to determine the information requirements. Content validity and test-retest method was used to measure validity and reliability of questioner respectively. Data analyzed with average index, using SPSS. Also Visual Paradigm software was used to design a conceptual model. Based on the requirements assessment of experts and related texts, administrative, demographic and clinical data and radiological examination results and if the anesthesia procedure performed, anesthesia data suggested as minimum data set for radiology report and based it class diagram designed. Also by identifying radiology reporting system process, use case was drawn. According to the application of radiology reports in electronic health record system for diagnosing and managing of clinical problem of the patient, with providing the conceptual Model for radiology reporting system; in order to systematically design it, the problem of data sharing between these systems and electronic health records system would eliminate.

  16. Electronic journals and scholarly communication: a citation and reference study

    Directory of Open Access Journals (Sweden)

    Stephen P. Harter

    1996-01-01

    Full Text Available The journal is fundamental to formal scholarly communication. This research reports highlights and preliminary findings from an empirical study of scholarly electronic journals. The purpose of the research is to assess the impact of electronic journals (e-journals on scholarly communication, by measuring the extent to which they are being cited in the literature, both print and electronic. The intent is to provide a snapshot of the impact e-journals were having on scholarly communication at a given point in time, roughly the end of 1995. This study provides one measure of that impact, specifically on the formal, as opposed to informal, communication process. The study also examines the forms in which scholars cite e-journals, the accuracy and completeness of citations to e-journals, and practical difficulties faced by scholars and researchers who wish to retrieve e-journals through the networks.

  17. On the use of Gafchromic EBT3 films for validating a commercial electron Monte Carlo dose calculation algorithm.

    Science.gov (United States)

    Chan, EuJin; Lydon, Jenny; Kron, Tomas

    2015-03-07

    This study aims to investigate the effects of oblique incidence, small field size and inhomogeneous media on the electron dose distribution, and to compare calculated (Elekta/CMS XiO) and measured results. All comparisons were done in terms of absolute dose. A new measuring method was developed for high resolution, absolute dose measurement of non-standard beams using Gafchromic® EBT3 film. A portable U-shaped holder was designed and constructed to hold EBT3 films vertically in a reproducible setup submerged in a water phantom. The experimental film method was verified with ionisation chamber measurements and agreed to within 2% or 1 mm. Agreement between XiO electron Monte Carlo (eMC) and EBT3 was within 2% or 2 mm for most standard fields and 3% or 3 mm for the non-standard fields. Larger differences were seen in the build-up region where XiO eMC overestimates dose by up to 10% for obliquely incident fields and underestimates the dose for small circular fields by up to 5% when compared to measurement. Calculations with inhomogeneous media mimicking ribs, lung and skull tissue placed at the side of the film in water agreed with measurement to within 3% or 3 mm. Gafchromic film in water proved to be a convenient high spatial resolution method to verify dose distributions from electrons in non-standard conditions including irradiation in inhomogeneous media.

  18. Experimental study of fast electron transport in dense plasmas

    International Nuclear Information System (INIS)

    Vaisseau, Xavier

    2014-01-01

    The framework of this PhD thesis is the inertial confinement fusion for energy production, in the context of the electron fast ignition scheme. The work consists in a characterization of the transport mechanisms of fast electrons, driven by intense laser pulses (10 19 - 10 20 W/cm 2 ) in both cold-solid and warm-dense matter. The first goal was to study the propagation of a fast electron beam, characterized by a current density ≥ 10 11 A/cm 2 , in aluminum targets initially heated close to the Fermi temperature by a counter-propagative planar shock. The planar compression geometry allowed us to discriminate the energy losses due to the resistive mechanisms from collisional ones by comparing solid and compressed targets of the same initial areal densities. We observed for the first time a significant increase of resistive energy losses in heated aluminum samples. The confrontation of the experimental data with the simulations, including a complete characterization of the electron source, of the target compression and of the fast electron transport, allowed us to study the time-evolution of the material resistivity. The estimated resistive electron stopping power in a warm-compressed target is of the same order as the collisional one. We studied the transport of the fast electrons generated in the interaction of a high-contrast laser pulse with a hollow copper cone, buried into a carbon layer, compressed by a counter-propagative planar shock. A X-ray imaging system allowed us to visualize the coupling of the laser pulse with the cone at different moments of the compression. This diagnostic, giving access to the fast electron spatial distribution, showed a fast electron generation in the entire volume of the cone for late times of compression, after shock breakout from the inner cone tip. For earlier times, the interaction at a high-contrast ensured that the source was contained within the cone tip, and the fast electron beam was collimated into the target depth by

  19. Studies of runaway electrons via Cherenkov effect in tokamaks

    Science.gov (United States)

    Zebrowski, J.; Jakubowski, L.; Rabinski, M.; Sadowski, M. J.; Jakubowski, M. J.; Kwiatkowski, R.; Malinowski, K.; Mirowski, R.; Mlynar, J.; Ficker, O.; Weinzettl, V.; Causa, F.; COMPASS; FTU Teams

    2018-01-01

    The paper concerns measurements of runaway electrons (REs) which are generated during discharges in tokamaks. The control of REs is an important task in experimental studies within the ITER-physics program. The NCBJ team proposed to study REs by means of Cherenkov-type detectors several years ago. The Cherenkov radiation, induced by REs in appropriate radiators, makes it possible to identify fast electron beams and to determine their spatial- and temporal-characteristics. The results of recent experimental studies of REs, performed in two tokamaks - COMPASS in Prague and FTU in Frascati, are summarized and discussed in this paper. Examples of the electron-induced signals, as recorded at different experimental conditions and scenarios, are presented. Measurements performed with a three-channel Cherenkov-probe in COMPASS showed that the first fast electron peaks can be observed already during the current ramp-up phase. A strong dependence of RE-signals on the radial position of the Cherenkov probe was observed. The most distinct electron peaks were recorded during the plasma disruption. The Cherenkov signals confirmed the appearance of post-disruptive RE beams in circular-plasma discharges with massive Ar-puffing. During experiments at FTU a clear correlation between the Cherenkov detector signals and the rotation of magnetic islands was identified.

  20. Validation study of safety assessment model for radioactive waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Munakata, Masahiro; Takeda, Seiji; Kimura, Hideo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-12-01

    The JAERI-AECL collaboration research program has been conducted to validate a groundwater flow and radionuclide transport models for safety assessment. JAERI have developed a geostatistical model for radionuclide transport through a heterogeneous geological media and verify using experimental results of field tracer tests. The simulated tracer plumes explain favorably the experimental tracer plumes. A regional groundwater flow and transport model using site-scale parameter obtained from tracer tests have been verified by comparing simulation results with observation ones of natural environmental tracer. (author)

  1. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  2. Study of absorbed dose distribution to high energy electron beams

    International Nuclear Information System (INIS)

    Cecatti, E.R.

    1983-01-01

    The depth absorbed dose distribution by electron beams was studied. The influence of the beam energy, the energy spread, field size and design characteristics of the accelerator was relieved. Three accelerators with different scattering and collimation systems were studied leading todifferent depth dose distributions. A theoretical model was constructed in order to explain the increase in the depth dose in the build-up region with the increase of the energy. The model utilizes a three-dimensional formalism based on the Fermi-Eyges multiple scattering theory, with the introduction of modifications that takes into account the criation of secondary electrons. (Author) [pt

  3. 40 CFR 152.93 - Citation of a previously submitted valid study.

    Science.gov (United States)

    2010-07-01

    ... Data Submitters' Rights § 152.93 Citation of a previously submitted valid study. An applicant may demonstrate compliance for a data requirement by citing a valid study previously submitted to the Agency. The... the original data submitter, the applicant may cite the study only in accordance with paragraphs (b...

  4. Instrument for assessing mobile technology acceptability in diabetes self-management: a validation and reliability study.

    Science.gov (United States)

    Frandes, Mirela; Deiac, Anca V; Timar, Bogdan; Lungeanu, Diana

    2017-01-01

    Nowadays, mobile technologies are part of everyday life, but the lack of instruments to assess their acceptability for the management of chronic diseases makes their actual adoption for this purpose slow. The objective of this study was to develop a survey instrument for assessing patients' attitude toward and intention to use mobile technology for diabetes mellitus (DM) self-management, as well as to identify sociodemographic characteristics and quality of life factors that affect them. We first conducted the documentation and instrument design phases, which were subsequently followed by the pilot study and instrument validation. Afterward, the instrument was administered 103 patients (median age: 37 years; range: 18-65 years) diagnosed with type 1 or type 2 DM, who accepted to participate in the study. The reliability and construct validity were assessed by computing Cronbach's alpha and using factor analysis, respectively. The instrument included statements about the actual use of electronic devices for DM management, interaction between patient and physician, attitude toward using mobile technology, and quality of life evaluation. Cronbach's alpha was 0.9 for attitude toward using mobile technology and 0.97 for attitude toward using mobile device applications for DM self-management. Younger patients (Spearman's ρ =-0.429; P higher education level (Kendall's τ =0.51; P mobile assistive applications for DM control. Moreover, patients with a higher quality of life presented a significantly more positive attitude toward using modern technology (Spearman's ρ =0.466; P mobile technology for DM self-management. Additionally, we found that even if most of the patients showed positive attitude toward mobile applications, only a moderate level of intention to indeed use them was observed. Moreover, the study indicated that barriers were truthfulness and easiness to use.

  5. Electron holography study on the microstructure of magnetic tunnelling junctions

    International Nuclear Information System (INIS)

    Xu, Q.Y.; Wang, Y.G.; You, B.; Du, J.; Hu, A.; Zhang, Z.

    2004-01-01

    Electron holography was applied to study the microstructure evolution of magnetic tunnelling junctions (MTJs) CoFe/AlO x /Co annealed at different temperatures. A mean inner potential barrier was observed in the as-deposited MTJ sample, while it was changed to a potential well after a 200 deg. C or a 400 deg. C annealing. It is suggested that the oxygen atoms were redistributed during the annealing, which left metallic atoms acting as acceptors to confine the electrons, leading to the decrease of the potential of the AlO x barrier layer. The results suggest that the electron holography may be a useful tool for the study of the microstructure of amorphous materials

  6. High-pressure electron-resonance studies of electronic, magnetic, and structural phase transitions. Progress report

    International Nuclear Information System (INIS)

    Pifer, J.H.; Croft, M.C.

    1983-01-01

    Research is described in development of a high-pressure electron-resonance probe capable of operating down to 1.5 0 K temperatures. The apparatus has been used to measure the EPR of a sample of DPPH at room temperature and zero pressure. EPR has been used to measure valence field instabilities in alloy systems. Studies have been done on metal-insulator transitions at high pressure, and are briefly described

  7. NMR studies of transmembrane electron transport in human erythrocytes

    International Nuclear Information System (INIS)

    Kennett, E.C.; Bubb, W.A.; Kuchel, P.W.

    2002-01-01

    Full text: Electron transport systems exist in the plasma membranes of all cells. These systems appear to play a role in cell growth and proliferation, intracellular signalling, hormone responses, apoptotic events, cell defence and perhaps most importantly they enable the cell to respond to changes in the redox state of both the intra- and extracellular environments. Previously, 13 C NMR has been used to study transmembrane electron transport in human erythrocytes, specifically the reduction of extracellular 13 C-ferricyanide. NMR is a particularly useful tool for studying such systems as changes in the metabolic state of the cell can be observed concomitantly with extracellular reductase activity. We investigated the oxidation of extracellular NADH by human erythrocytes using 1 H and 31 P NMR spectroscopy. Recent results for glucose-starved human erythrocytes indicate that, under these conditions, extracellular NADH can be oxidised at the plasma membrane with the electron transfer across the membrane resulting in reduction of intracellular NAD + . The activity is inhibited by known trans-plasma membrane electron transport inhibitors (capsaicin and atebrin) and is unaffected by inhibition of the erythrocyte Band 3 anion transporter. These results suggest that electron import from extracellular NADH allows the cell to re-establish a reducing environment after the normal redox balance is disturbed

  8. Experimental study on generation of large area uniform electron beam

    International Nuclear Information System (INIS)

    Tang Ying; Yi Aiping; Liu Jingru; Qian Hang; Huang Xin; Yu Li; Su Jiancang; Ding Zhenjie; Ding Yongzhong; Yu Jianguo

    2007-01-01

    In the experiment of gas laser pumped by electron beam, large area uniform electron beam is important to generate high efficiency laser output. The experimental study on generation of large area uniform electron beam with SPG-200 pulsed power generator is introduced. SPG-200 is an all-solid-state components pulsed power generator based on SOS, and its open voltage is more than 350 kV. The cathode have the area of 24 mm x 294 mm, and the anode-cathode(A-C)gap spacing is adjustable from 0 to 49 mm. The electron beam of cathode emission is transported to the laser chamber through the diode pressure foil, which sepa-rates the vacuum chamber from the laser chamber. Velvet and graphite cathodes are studied, each generates large area electron beam. The diode parameters are presented, and the uniformity of e-beam is diagnosed. The experimental results show that the diode voltage of the graphite cathode is 240-280 kV, and the diode current is 0.7-1.8 kA. The diode voltage of the velvet cathode is 200-250 kV, and the diode current is 1.5-1.7 kA. The uniformity of the velvet cathode emission is better than that of the graphite cathode. (authors)

  9. Dynamic electron arc radiotherapy (DEAR): a feasibility study

    International Nuclear Information System (INIS)

    Rodrigues, Anna; Yin, Fang-Fang; Wu, Qiuwen

    2014-01-01

    Compared to other radiation therapy modalities, clinical electron beam therapy has remained practically unchanged for the past few decades even though electron beams with multiple energies are widely available on most linacs. In this paper, we present the concept of dynamic electron arc radiotherapy (DEAR), a new conformal electron therapy technique with synchronized couch motion. DEAR utilizes combination of gantry rotation, couch motion, and dose rate modulation to achieve desirable dose distributions in patient. The electron applicator is kept to minimize scatter and maintain narrow penumbra. The couch motion is synchronized with the gantry rotation to avoid collision between patient and the electron cone. In this study, we investigate the feasibility of DEAR delivery and demonstrate the potential of DEAR to improve dose distributions on simple cylindrical phantoms. DEAR was delivered on Varian's TrueBeam linac in Research Mode. In conjunction with the recorded trajectory log files, mechanical motion accuracies and dose rate modulation precision were analyzed. Experimental and calculated dose distributions were investigated for different energies (6 and 9 MeV) and cut-out sizes (1×10 cm 2  and 3×10 cm 2  for a 15×15 cm 2  applicator). Our findings show that DEAR delivery is feasible and has the potential to deliver radiation dose with high accuracy (root mean square error, or RMSE of <0.1 MU, <0.1° gantry, and <0.1 cm couch positions) and good dose rate precision (1.6 MU min −1 ). Dose homogeneity within ±2% in large and curved targets can be achieved while maintaining penumbra comparable to a standard electron beam on a flat surface. Further, DEAR does not require fabrication of patient-specific shields. These benefits make DEAR a promising technique for conformal radiotherapy of superficial tumors. (paper)

  10. Study of fast electrons from hard-X radiation

    International Nuclear Information System (INIS)

    Arslanbekov, R.

    1995-01-01

    The goal of this thesis is the study of fast electron dynamics by means of the hard X-ray diagnosis installed in TORE SUPRA and numerical simulations. Fast electrons are generated in the plasma in the presence of the injected lower hybrid (LH) waves. Two aspects are studied in detail: the lower hybrid wave propagation and absorption in a periodically perturbed media and 2-D Fokker-Planck modelling of the fast electron dynamics in the presence of the LH power. Ripple effects on lower hybrid wave propagation and absorption are investigated using the ray tracing technique. A cylindrical equilibrium is first studied and a strong modification of the ray dynamics is predicted. Calculations are carried out in a real toroidal geometry corresponding to TORE SUPRA. It is shown that the lack of toroidal axisymmetry of the magnetic field may result in a modification of the ray evolution even if the global ray evolution is governed by the larger poloidal inhomogeneity. Simulation of LH experiments are performed for TORE SUPRA tokamak which has a large magnetic ripple (7% at the plasma edge). By considering ripple perturbation in LH current drive simulations, a better agreement is found with experimental results, in particular with the hard-X spectra and the current density profiles. In the second part of the thesis, a 2-D modeling of the fast electron dynamics in the velocity phase space is considered, based on the 2-D relativistic electron Fokker-Planck equation. Electron distribution functions obtained are used to calculate non-thermal Bremsstrahlung emission for different TORE SUPRA shots in a wide range of experimental conditions. (J.S.). 168 refs., 93 figs., 1 tab., 3 appendix

  11. Workplace Bullying Scale: The Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Nizamettin Doğar

    2015-01-01

    Full Text Available The aim of this research is to adapt the Workplace Bullying Scale (Tınaz, Gök & Karatuna, 2013 to Albanian language and to examine its psychometric properties. The research was conducted on 386 person from different sectors of Albania. Results of exploratory and confirmatory factor analysis demonstrated that Albanian scale yielded 2 factors different from original form because of cultural differences. Internal consistency coefficients are,890 -,801 and split-half test reliability coefficients, 864 -,808. Comfirmatory Factor Analysis results change from,40 to,73. Corrected item-total correlations ranged,339 to,672 and according to t-test results differences between each item’s means of upper 27% and lower 27% points were significant. Thus Workplace Bullying Scale can be use as a valid and reliable instrument in social sciences in Albania.

  12. Large Scale Simulation Platform for NODES Validation Study

    Energy Technology Data Exchange (ETDEWEB)

    Sotorrio, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Qin, Y. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Min, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-27

    This report summarizes the Large Scale (LS) simulation platform created for the Eaton NODES project. The simulation environment consists of both wholesale market simulator and distribution simulator and includes the CAISO wholesale market model and a PG&E footprint of 25-75 feeders to validate the scalability under a scenario of 33% RPS in California with additional 17% of DERS coming from distribution and customers. The simulator can generate hourly unit commitment, 5-minute economic dispatch, and 4-second AGC regulation signals. The simulator is also capable of simulating greater than 10k individual controllable devices. Simulated DERs include water heaters, EVs, residential and light commercial HVAC/buildings, and residential-level battery storage. Feeder-level voltage regulators and capacitor banks are also simulated for feeder-level real and reactive power management and Vol/Var control.

  13. Comparative calculations and validation studies with atmospheric dispersion models

    International Nuclear Information System (INIS)

    Paesler-Sauer, J.

    1986-11-01

    This report presents the results of an intercomparison of different mesoscale dispersion models and measured data of tracer experiments. The types of models taking part in the intercomparison are Gaussian-type, numerical Eulerian, and Lagrangian dispersion models. They are suited for the calculation of the atmospherical transport of radionuclides released from a nuclear installation. For the model intercomparison artificial meteorological situations were defined and corresponding arithmetical problems were formulated. For the purpose of model validation real dispersion situations of tracer experiments were used as input data for model calculations; in these cases calculated and measured time-integrated concentrations close to the ground are compared. Finally a valuation of the models concerning their efficiency in solving the problems is carried out by the aid of objective methods. (orig./HP) [de

  14. Quantum mechanics concept assessment: Development and validation study

    Directory of Open Access Journals (Sweden)

    Homeyra R. Sadaghiani

    2015-03-01

    Full Text Available As part of an ongoing investigation of students’ learning in first semester upper-division quantum mechanics, we needed a high-quality conceptual assessment instrument for comparing outcomes of different curricular approaches. The process of developing such a tool started with converting a preliminary version of a 14-item open-ended quantum mechanics assessment tool (QMAT to a multiple-choice (MC format. Further question refinement, development of effective distractors, adding new questions, and robust statistical analysis has led to a 31-item quantum mechanics concept assessment (QMCA test. The QMCA is used as post-test only to assess students’ knowledge about five main topics of quantum measurement: the time-independent Schrödinger equation, wave functions and boundary conditions, time evolution, and probability density. During two years of testing and refinement, the QMCA has been given in alpha (N=61 and beta versions (N=263 to students in upper division quantum mechanics courses at 11 different institutions with an average post-test score of 54%. By allowing for comparisons of student learning across different populations and institutions, the QMCA provides instructors and researchers a more standard measure of effectiveness of different curricula or teaching strategies on student conceptual understanding of quantum mechanics. In this paper, we discuss the construction of effective distractors and the use of student interviews and expert feedback to revise and validate both questions and distractors. We include the results of common statistical tests of reliability and validity, which suggest the instrument is presently in a stable, usable, and promising form.

  15. Study of an integrated electronic monitor for neutron beams

    International Nuclear Information System (INIS)

    Barelaud, B.; Nexon-Mokhtari, F.; Barrau, C.; Decossac, J.L.; Vareille, J.C.; Sarrabayrouse, G.

    1994-01-01

    Many neutron beams monitors in 10 keV - 50 keV range are perturbed by gamma radiation impact. This new monitor uses two silicon (junction) diodes operating coincidence detection, combined with an electronic threshold to eliminate gamma background noise. The results and analyses presented here only concern feasibility studies. (D.L.)

  16. The structure of spinach Photosystem I studied by electron microscopy

    NARCIS (Netherlands)

    Boekema, Egbert J.; Wynn, R. Max; Malkin, Richard

    1990-01-01

    The structure of three types of Photosystem I (PS I) complex isolated from spinach chloroplasts was studied by electron microscopy and computer image analysis. Molecular projections (top views and side views) of a native PS I complex (PSI-200), an antenna-depleted PS I complex (PSI-100) and the PS I

  17. [Scanning electron microscope study of chemically disinfected endodontic files].

    Science.gov (United States)

    Navarro, G; Mateos, M; Navarro, J L; Canalda, C

    1991-01-01

    Forty stainless steel endodontic files were observed at scanning electron microscopy after being subjected to ten disinfection cycles of 10 minutes each one, immersed in different chemical disinfectants. Corrosion was not observed on the surface of the files in circumstances that this study was made.

  18. Electron microscopy studies on MoS2 nanocrystals

    DEFF Research Database (Denmark)

    Hansen, Lars Pilsgaard

    Industrial-style MoS2-based hydrotreating catalysts are studied using electron microscopy. The MoS2 nanostructures are imaged with single-atom sensitivity to reveal the catalytically important edge structures. Furthermore, the in-situ formation of MoS2 crystals is imaged for the first time....

  19. A Comparative Study of Electronic Performance Support Systems

    Science.gov (United States)

    Nguyen, Frank; Klein, James D.; Sullivan, Howard

    2005-01-01

    Electronic performance support systems (EPSS) deliver relevant support information to users while they are performing tasks. The present study examined the effect of different types of EPSS on user performance, attitudes, system use and time on task. Employees at a manufacturing company were asked to complete a procedural software task and…

  20. Inventory Control: A Small Electronic Device for Studying Chemical Kinetics.

    Science.gov (United States)

    Perez-Rodriguez, A. L.; Calvo-Aguilar, J. L.

    1984-01-01

    Shows how the rate of reaction can be studied using a simple electronic device that overcomes the difficulty students encounter in solving the differential equations describing chemical equilibrium. The device, used in conjunction with an oscilloscope, supplies the voltages that represent the chemical variables that take part in the equilibrium.…

  1. Study of an integrated electronic monitor for neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Barelaud, B.; Nexon-Mokhtari, F.; Barrau, C.; Decossac, J.L.; Vareille, J.C. [Limoges Univ., 87 (France); Sarrabayrouse, G. [Centre National de la Recherche Scientifique (CNRS), 31 - Toulouse (France). Lab. d`Automatique et d`Analyse des Systemes

    1994-12-31

    Many neutron beams monitors in 10 keV - 50 keV range are perturbed by gamma radiation impact. This new monitor uses two silicon (junction) diodes operating coincidence detection, combined with an electronic threshold to eliminate gamma background noise. The results and analyses presented here only concern feasibility studies. (D.L.). 11 refs.

  2. Experimental study of intensive electron beam scattering in melting channel

    International Nuclear Information System (INIS)

    Balagura, V.S.; Kurilko, V.I.; Safronov, B.G.

    1988-01-01

    Multiple scattering of an intensive electron beam at 28 keV energy passing through a melting channel in iron targets is experimentally studied. The dependence of scattering on the melting current value is established. The material density in the channel on the basis of the binary collision method is evaluated. It is shown that these density values are of three orders less than the estimations made on the basis of the data on energy losses of electrons in the channel. 6 refs.; 4 figs

  3. Surface study of liquid 3He using surface state electrons

    International Nuclear Information System (INIS)

    Shirahama, K.; Ito, S.; Suto, H.; Kono, K.

    1995-01-01

    We have measured the mobility of surface state electrons (SSE) on liquid 3 He, μ 3 , aiming to study the elementary surface excitations of the Fermi liquid. A gradual increase of μ 3 below 300 mK is attributed to the scattering of electrons by ripplons. Ripplons do exist in 3 He down to 100 mK. We observe an abrupt decrease of μ 3 , due to the transition to the Wigner solid (WS). The dependences of the WS conductivity and mobility on temperature and magnetic field differ from the SSE behavior on liquid 4 He

  4. Study and realization of an electron linear accelerator. Dynamics of accelerated electrons

    International Nuclear Information System (INIS)

    Bernard, J.

    1966-12-01

    The theoretical characteristics of the electron linear accelerator are: 30 MeV for the energy W S and 250 mA for the peak current I c . The main utilization is the intense production of fast neutrons by the reactions (γ,n) and (γ,f) induced in a target of natural uranium by the accelerated electrons. In the first part of the thesis, relative to the study and the realization of the accelerator, a new equation of dispersion is established analytically when the guide is loaded with round-edged irises. The relation is compared with the equation established by CHU and Hansen, WALKINSHAW, KVASIL in the case of a guide loaded with flat-edged irises. The experimental and theoretical curves of dispersion are compared. The accuracy of every relation of dispersion is estimated. The second part of the thesis is relative to the theoretical study of the electrons dynamics in the guide; it allows the derivation of the parameters of the beam: dispersion of phase, energy, dispersion of energy and the relation W S = f (I c ). The results relative to the first experiments are given and compared with the theoretical expectations. (author) [fr

  5. Study of Compton broadening due to electron-photon scattering

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao M.

    2010-01-01

    Full Text Available We have investigated the effects of Compton broadening due to electron-photon scattering in hot stellar atmospheres. A purely electron-photon scattering media is assumed to have plane parallel geometry with an input radia­tion field localized on one side of the slab. The method is based on the discrete space theory of radiative transfer for the intensity of emitted radiation. The solution is developed to study the importance of scattering of radiation by free electrons in high temperature stellar atmospheres which produces a brodening and shift in spectral lines because of the Compton effect and the Doppler effect arising from mass and thermal motions of scattering electrons. It is noticed that the Comptonized spectrum depends on three parameters: the optical depth of the medium, the temperature of the thermal electrons and the viewing angle. We also showed that the Compton effect produces red shift and asymmetry in the line. These two effects increase as the optical depth increases. It is also noticed that the emergent specific intensities become completely asymmetric for higher optical depths.

  6. Study of Compton Broadening Due to Electron-Photon Scattering

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao, M.

    2010-06-01

    Full Text Available We have investigated the effects of Compton broadening due to electron-photon scattering in hot stellar atmospheres. A purely electron-photon scattering media is assumed to have plane parallel geometry with an input radiation field localized on one side of the slab. The method is based on the discrete space theory of radiative transfer for the intensity of emitted radiation.The solution is developed to study the importance of scattering of radiation by free electrons in high temperature stellar atmospheres which produces a brodening and shift in spectral lines because of the Compton effect and the Doppler effect arising from mass and thermal motions of scattering electrons.It is noticed that the Comptonized spectrum depends on three parameters: the optical depth of the medium, the temperature of the thermal electrons and the viewing angle.We also showed that the Compton effect produces red shift and asymmetry in the line. These two effects increase as the optical depth increases. It is also noticed that the emergent specific intensities become completely asymmetric for higher optical depths.

  7. Dosimetry study for electron beam irradiation in radiation processing

    International Nuclear Information System (INIS)

    Sunaga, Hiromi; Haruyama, Yasuyuki; Takizawa, Haruki; Kojima, Takuji; Yotsumoto, Keiichi

    1995-01-01

    For certain critical applications such as medical device sterilization and food irradiation, accurate calibration of electron energy and absorbed dose is required to assure the quality of irradiated products. To meet this requirement, TRCRE, JAERI has carried out research and development on high dose radiation dosimetry for electron beams in the energy range used in radiation processing (0.15 - 3.0 MeV). JAERI has developed a simultaneous electron beam energy and dosimeter calibration system that consist of a total absorption calorimeter, an electron current density meter, and a stacked thin-film dosimeter set. For low energy electrons, where it is important to measure the depth-dose profile in materials with high depth resolution, we studied the feasibility of a method using Gafchromic film dosimeters. This film, which has an 8-μm thick sensitive layer, is combined with a stepped array of absorber films of the same thickness to produce a high-resolution depth-dose profile on the Gafchromic film. The depth-dose profile obtained in this manner has about five times greater resolution than conventional radiochromic film dosimetry. (author)

  8. Preliminary Design Study of the Hollow Electron Lens for LHC

    CERN Document Server

    Perini, Diego; CERN. Geneva. ATS Department

    2017-01-01

    A Hollow Electron Lens (HEL) has been proposed in order to improve performance of halo control and collimation in the Large Hadron Collider in view of its High Luminosity upgrade (HL-LHC). The concept is based on a beam of electrons that travels around the protons for a few meters. The electron beam is produced by a cathode and then guided by a strong magnetic field generated by a set of superconducting solenoids. The first step of the design is the definition of the magnetic fields that drive the electron trajectories. The estimation of such trajectories by means of a dedicated MATLAB® tool is presented. The influence of the main geometrical and electrical parameters are analysed and discussed. Then, the main mechanical design choices for the solenoids, cryostats gun and collector are described. The aim of this paper is to provide an overview of the preliminary design of the Electron Lens for LHC. The methods used in this study also serve as examples for future mechanical and integration designs of similar ...

  9. Test beam studies for the atlas tile calorimeter readout electronics

    CERN Document Server

    Rodriguez Perez, Andrea; The ATLAS collaboration

    2018-01-01

    The Large Hadron Collider (LHC) Phase II upgrade aims to increase the accelerator luminosity by a factor of 5-10. Due to the expected higher radiation levels and the aging of the current electronics, a new readout system for the Tile hadronic calorimeter (TileCal) of the ATLAS experiment is needed. A prototype of the upgrade TileCal electronics has been tested using the beam from the Super Proton Synchrotron (SPS) accelerator at CERN. Data were collected with beams of muons, electrons and hadrons at various incident energies and impact angles. The muon data allow to study the response dependence on the incident point and angle in a cell and inter-calibration of the response between cells. The electron data are used to determine the linearity of the electron energy measurement. The hadron data allow to determined the calorimeter response to pions, kaons and protons and tune the calorimeter simulation to that data. The results of the ongoing data analyses are discussed in the presentation.

  10. Study of runaway electron generation during major disruptions in JET

    International Nuclear Information System (INIS)

    Plyusnin, V.V.; Riccardo, V.; Jaspers, R.; Alper, B.; Kiptily, V.G.; Mlynar, J.; Popovichev, S.; Luna, E. de La; Andersson, F.

    2006-01-01

    Extensive analysis of disruptions in JET has helped advance the understanding of trends of disruption-generated runaway electrons. Tomographic reconstruction of the soft x-ray emission has made possible a detailed observation of the magnetic flux geometry evolution during disruptions. With the aid of soft and hard x-ray diagnostics runaway electrons have been detected at the very beginning of disruptions. A study of runaway electron parameters has shown that an approximate upper bound for the conversion efficiency of pre-disruptive plasma currents into runaways is about 60% over a wide range of plasma currents in JET. Runaway generation has been simulated with a test particle model in order to verify the results of experimental data analysis and to obtain the background for extrapolation of the existing results onto larger devices such as ITER. It was found that close agreement between the modelling results and experimental data could be achieved if in the calculations the post-disruption plasma electron temperature was assumed equal to 10 eV and if the plasma column geometry evolution is taken into account in calculations. The experimental trends and numerical simulations show that runaway electrons are a critical issue for ITER and, therefore, the development of mitigation methods, which suppress runaway generation, is an essential task

  11. Proteomic signatures of infertile men with clinical varicocele and their validation studies reveal mitochondrial dysfunction leading to infertility

    Directory of Open Access Journals (Sweden)

    Ashok Agarwal

    2016-01-01

    Full Text Available To study the major differences in the distribution of spermatozoa proteins in infertile men with varicocele by comparative proteomics and validation of their level of expression. The study-specific estimates for each varicocele outcome were combined to identify the proteins involved in varicocele-associated infertility in men irrespective of stage and laterality of their clinical varicocele. Expression levels of 5 key proteins (PKAR1A, AK7, CCT6B, HSPA2, and ODF2 involved in stress response and sperm function including molecular chaperones were validated by Western blotting. Ninety-nine proteins were differentially expressed in the varicocele group. Over 87% of the DEP involved in major energy metabolism and key sperm functions were underexpressed in the varicocele group. Key protein functions affected in the varicocele group were spermatogenesis, sperm motility, and mitochondrial dysfunction, which were further validated by Western blotting, corroborating the proteomics analysis. Varicocele is essentially a state of energy deprivation, hypoxia, and hyperthermia due to impaired blood supply, which is corroborated by down-regulation of lipid metabolism, mitochondrial electron transport chain, and Krebs cycle enzymes. To corroborate the proteomic analysis, expression of the 5 identified proteins of interest was validated by Western blotting. This study contributes toward establishing a biomarker "fingerprint" to assess sperm quality on the basis of molecular parameters.

  12. A design study of non-adiabatic electron guns

    International Nuclear Information System (INIS)

    Barroso, J.J.; Stellati, C.

    1994-01-01

    The design of a non-adiabatic gun capable of producing a 10 A, 50 KeV high-quality laminar electron beam is reported. In contrast to the magnetron injection gun with a conical cathode, where the beam is generated initially with a transverse velocity component, in the non-adiabatic gun electrons are extracted in a direction parallel to the axial guide magnetic field. The beam electrons acquire cyclotron motion as result of non-adiabatic processes in a strong non uniform electric field across the modulation anode. Such an extraction method gives rise to favourable features that are explored throughout the work. An extensive numerical simulation study has also been done to minimize velocity and energy spreads. (author). 3 refs, 5 figs, 1 tab

  13. Study of polysilane mainchain electronic structure by picosecond pulse radiolysis

    International Nuclear Information System (INIS)

    Habara, H.; Saeki, A.; Kunimi, Y.; Seki, S.; Kozawa, T.; Yoshida, Y.; Tagawa, S.

    2000-01-01

    The electronic structure of a charged polysilane molecle is studied. The transient absorption spectroscopy was carried out for charged radicals of poly (methylphenylsilane): PMPS by pico-second and nanosecond pulse radiolysis technique. It was observed that the peak of the transient absorption spectra shifted to longer wavelength region within a few nsec, and an increase was observed in the optical density at 370 nm, which had been already assigned to the radical anions of PMPS. It is ascribed to inter-segment electron transfer (intra-molecular transfer) through polymer chain. The nanosecond pulse radiolysis experiments gave similar kinetic traces in near-UV and IR region. This suggests the presence of an interband level, that is, a polaron level occupied by an excess electron or a hole. (author)

  14. Development of Creative Behavior Observation Form: A Study on Validity and Reliability

    Science.gov (United States)

    Dere, Zeynep; Ömeroglu, Esra

    2018-01-01

    This study, Creative Behavior Observation Form was developed to assess creativity of the children. While the study group on the reliability and validity of Creative Behavior Observation Form was being developed, 257 children in total who were at the ages of 5-6 were used as samples with stratified sampling method. Content Validity Index (CVI) and…

  15. Turkish Adaptation of the Mentorship Effectiveness Scale: A Validity and Reliability Study

    Science.gov (United States)

    Yirci, Ramazan; Karakose, Turgut; Uygun, Harun; Ozdemir, Tuncay Yavuz

    2016-01-01

    The purpose of this study is to adapt the Mentoring Relationship Effectiveness Scale to Turkish, and to conduct validity and reliability tests regarding the scale. The study group consisted of 156 university science students receiving graduate education. Construct validity and factor structure of the scale was analyzed first through exploratory…

  16. Turkish Version of Kolcaba's Immobilization Comfort Questionnaire: A Validity and Reliability Study.

    Science.gov (United States)

    Tosun, Betül; Aslan, Özlem; Tunay, Servet; Akyüz, Aygül; Özkan, Hüseyin; Bek, Doğan; Açıksöz, Semra

    2015-12-01

    The purpose of this study was to determine the validity and reliability of the Turkish version of the Immobilization Comfort Questionnaire (ICQ). The sample used in this methodological study consisted of 121 patients undergoing lower extremity arthroscopy in a training and research hospital. The validity study of the questionnaire assessed language validity, structural validity and criterion validity. Structural validity was evaluated via exploratory factor analysis. Criterion validity was evaluated by assessing the correlation between the visual analog scale (VAS) scores (i.e., the comfort and pain VAS scores) and the ICQ scores using Spearman's correlation test. The Kaiser-Meyer-Olkin coefficient and Bartlett's test of sphericity were used to determine the suitability of the data for factor analysis. Internal consistency was evaluated to determine reliability. The data were analyzed with SPSS version 15.00 for Windows. Descriptive statistics were presented as frequencies, percentages, means and standard deviations. A p value ≤ .05 was considered statistically significant. A moderate positive correlation was found between the ICQ scores and the VAS comfort scores; a moderate negative correlation was found between the ICQ and the VAS pain measures in the criterion validity analysis. Cronbach α values of .75 and .82 were found for the first and second measurements, respectively. The findings of this study reveal that the ICQ is a valid and reliable tool for assessing the comfort of patients in Turkey who are immobilized because of lower extremity orthopedic problems. Copyright © 2015. Published by Elsevier B.V.

  17. Electronics

    Science.gov (United States)

    2001-01-01

    International Acer Incorporated, Hsin Chu, Taiwan Aerospace Industrial Development Corporation, Taichung, Taiwan American Institute of Taiwan, Taipei, Taiwan...Singapore and Malaysia .5 - 4 - The largest market for semiconductor products is the high technology consumer electronics industry that consumes up...Singapore, and Malaysia . A new semiconductor facility costs around $3 billion to build and takes about two years to become operational

  18. Experimental study of fast electron transport in the framework of fast ignition for inertial fusion

    International Nuclear Information System (INIS)

    Vauzour, B.

    2012-01-01

    The framework of this PhD thesis is the validation of the fast ignition scheme for the nuclear fusion by inertial confinement. It consists in the experimental study of the various processes involved in fast electron beams propagation, produced by intense laser pulses (10 19 W.cm -2 ), through dense matter either solid or compressed. In this work we present the results of three experiments carried out on different laser facilities in order to generate fast electron beams in various conditions and study their propagation in different states of matter, from the cold solid to the warm and dense plasma.The first experiment was performed with a high intensity contrast on the UHI100 laser facility (CEA Saclay). The study of fast electron energy deposition inside thin aluminium targets highlights a strong target heating at shallow depths, where the collective effects are predominant, thus producing a steep temperature profile between front (300 eV) and rear (20 eV) sides over 20μm thickness. A numerical simulation of the experiment shows that this temperature gradient induces the formation of a shock wave, breaking through the rear side of the target and thus leading to increase the thermal emission. The experimental chronometry of the shock breakthrough allowed validating the model of the collective transport of electrons.Two other experiments were dedicated to the study of fast electron beam propagation inside compressed targets. In the first experiment on the LULI2000 laser facility, the plane compression geometry allowed to precisely dissociate the energy losses due to resistive effects from those due to the collisional ones. By comparing our experimental results with simulations, we observed a significative increase of the fast electron beam energy losses with the compression and the target heating to temperatures close to the Fermi temperature. The second experiment, performed in a cylindrical geometry, demonstrated a fast electron beam guiding phenomenon due to

  19. Neo-Institutional Approach to the Study of Electronic Government

    Directory of Open Access Journals (Sweden)

    Yan I. Vaslavskiy

    2016-01-01

    Full Text Available The article is devoted to the neo-institutional approach as a methodological basis in the study of electronic government. In this article substantiates the choice of neo-institutional approach to the study of the processes of implementation of information and communication technologies in the activity of state institutions, analyzes the differences of neoinstitutionalism from traditional institutional approach, considers the features of the different directions of neo-institutionalism, namely sociological, historical and rational choice theory. Attention is paid to the reasons for the renewed interest in political institutions in political science. The article emphasizes the importance of considering the electronic government as an institution, and the conditions for its implementation in the Russian political system as the institutional environment. The authors pay special attention to the variety of sociological neo-institutionalism, used, in addition to political science in sociology of organizations. The article substantiates the value of using sociological institutionalism to explore the electronic government based on a comparative analysis of e-government projects in Russia and abroad and explores its heuristic capabilities. It examines the impact of the system of norms and values of the institutional environment on the processes of formation and development of electronic government in Russia. The research capacity of this theory is due to the fact that it allows us to trace the reasons for copying and replication of inefficient practices and organizational and management schemes, to identify the factors impeding innovation use by the state of electronic interaction technologies. It is emphasized that the use of the theory of institutional isomorphism is useful in the sphere of implementation of electronic technologies, in which a key role play pluralism, horizontal managerial communication, inter-agency coordination.

  20. Psychometric validation of a new measurement instrument for time-oriented patient information in electronic medical records: A questionnaire survey of physicians.

    Science.gov (United States)

    Shibuya, Akiko; Misawa, Jimpei; Maeda, Yukihiro; Ichikawa, Rie; Kamata, Michiyo; Inoue, Ryusuke; Morimoto, Tetsuji; Nakayama, Masaharu; Hishiki, Teruyoshi; Kondo, Yoshiaki

    2017-12-01

    Time is an important element in medical data. Physicians record and store information about patients' disease progress and treatment response in electronic medical records (EMRs). Because EMRs use timestamps, physicians can identify patterns over time regarding a patient's disease and treatment (eg, laboratory values and medications). However, analyses of physicians' use and satisfaction with EMRs have focused on functionality, storage, and system operation rather than the use of time-oriented information. This study aimed to understand physicians' needs regarding time-oriented patient information in EMRs in clinical practice. The reliability and validity of the items in the questionnaire were evaluated in 87 physicians at a national university hospital. Internal consistency was satisfactory (Cronbach alpha coefficient, 0.87). Four dimensions were identified in exploratory factor analysis. Correlations between the 4 dimensions supported the construct validity of the items. Scores of time-oriented patients' medical history in the 4 dimensions showed a significant association with physician age. Based on confirmatory factor analysis, associations were significant and positive (P information in EMRs, both time-oriented treatment results followed by time-oriented team information had significant positive associations. Our study suggests that 4 specific time-oriented patient information factors in EMRs are needed by physicians. Exploring physicians' needs regarding patient-specific time-oriented information may provide a better understanding of the barriers facing the adoption and use of EMRs (eg, decision-making and practice safety concerns) and lead to better acceptance of EMRs in physicians' clinical practices. © 2017 John Wiley & Sons, Ltd.

  1. Efficacy and External Validity of Electronic and Mobile Phone-Based Interventions Promoting Vegetable Intake in Young Adults: A Systematic Review Protocol.

    Science.gov (United States)

    Nour, Monica Marina; Chen, Juliana; Allman-Farinelli, Margaret

    2015-07-28

    Despite social marketing campaigns and behavior change interventions, young adults remain among the lowest consumers of vegetables. The digital era offers potential new avenues for both social marketing and individually tailored programs, through texting, web, and mobile applications. The effectiveness and generalizability of such programs have not been well documented. The aim of this systematic review is to evaluate the efficacy and external validity of social marketing, electronic, and mobile phone-based (mHealth) interventions aimed at increasing vegetable intake in young adults. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) protocol will be used to conduct this systematic review. The search strategy will be executed across eleven electronic databases using combinations of the following search terms: "online intervention", "computer-assisted therapy", "internet", "website", "cell phones", "cyber", "telemedicine", "email", "social marketing", "social media", "mass media", "young adult", and "fruit and vegetables". The reference lists of included studies will also be searched for additional citations. Titles and abstracts will be screened against inclusion criteria and full texts of potentially eligible papers will be assessed by two independent reviewers. Data from eligible papers will be extracted. Quality and risk of bias will be assessed using the Effective Public Health Practice Project (EPHPP) Quality Assessment Tool for Quantitative Studies and The Cochrane Collaboration Risk of Bias assessment tool respectively. The external validity of the studies will be determined based on components such as reach, adoption, and representativeness of participants; intervention implementation and adaption; and program maintenance and institutionalization. Results will be reported quantitatively and qualitatively. Our research is in progress. A draft of the systematic review is currently being produced for publication by the end of 2015

  2. Study and realization of an electron linear accelerator. Dynamics of accelerated electrons; Etude et realisation d'un accelerateur lineaire d'electrons. Dynamique des electrons acceleres

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-04-01

    The theoretical characteristics of the electron linear accelerator are: 30 MeV for the energy W{sub S} and 250 mA for the peak current I{sub c}. The main utilization is the intense production of fast neutrons by the reactions ({gamma},n) and ({gamma},f) induced in a target of natural uranium by the accelerated electrons. In the first part of the thesis, relative to the study and the realization of the accelerator, a new equation of dispersion is established analytically when the guide is loaded with round-edged irises. The relation is compared with the equation established by CHU and Hansen, WALKINSHAW, KVASIL in the case of a guide loaded with flat-edged irises. The experimental and theoretical curves of dispersion are compared. The accuracy of every relation of dispersion is estimated. The second part of the thesis is relative to the theoretical study of the electrons dynamics in the guide; it allows the derivation of the parameters of the beam: dispersion of phase, energy, dispersion of energy and the relation W{sub S} = f (I{sub c}). The results relative to the first experiments are given and compared with the theoretical expectations. (author) [French] Les caracteristiques nominales theoriques de l'accelerateur lineaire d'electrons sont: 30 MeV pour l'energie W{sub S} et 250 mA pour le courant de crete I{sub c}. L'utilisation principale envisagee est la production de neutrons rapides par les reactions ({gamma},n) et ({gamma},f) induites dans une cible d'uranium naturel par les electrons acceleres. Dans la premiere partie de la these relative a l'elude et a la realisation de l'accelerateur, une nouvelle equation de dispersion (ou equation aux frequences) est etablie analytiquement pour un guide charge par des iris a bord rond. Cette relation est comparee a celles etablies par CHU et HANSEN, WALKINSHAW, KVASIL dans le cas du guide charge par des iris a bord plat. On compare les courbes de dispersion theoriques et experimentales et on evalue la precision de

  3. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  4. Perceived Stress Scale: Reliability and Validity Study in Greece

    Directory of Open Access Journals (Sweden)

    Eleni Andreou

    2011-08-01

    Full Text Available Objective: To translate the Perceived Stress Scale (versions PSS-4, -10 and -14 and to assess its psychometric properties in a sample of general Greek population. Methods: 941 individuals completed anonymously questionnaires comprising of PSS, the Depression Anxiety and Stress scale (DASS-21 version, and a list of stress-related symptoms. Psychometric properties of PSS were investigated by confirmatory factor analysis (construct validity, Cronbach’s alpha (reliability, and by investigating relations with the DASS-21 scores and the number of symptoms, across individuals’ characteristics. The two-factor structure of PSS-10 and PSS-14 was confirmed in our analysis. We found satisfactory Cronbach’s alpha values (0.82 for the full scale for PSS-14 and PSS-10 and marginal satisfactory values for PSS-4 (0.69. PSS score exhibited high correlation coefficients with DASS-21 subscales scores, meaning stress (r = 0.64, depression (r = 0.61, and anxiety (r = 0.54. Women reported significantly more stress compared to men and divorced or widows compared to married or singled only. A strong significant (p < 0.001 positive correlation between the stress score and the number of self-reported symptoms was also noted. Conclusions: The Greek versions of the PSS-14 and PSS-10 exhibited satisfactory psychometric properties and their use for research and health care practice is warranted.

  5. Perceived Stress Scale: reliability and validity study in Greece.

    Science.gov (United States)

    Andreou, Eleni; Alexopoulos, Evangelos C; Lionis, Christos; Varvogli, Liza; Gnardellis, Charalambos; Chrousos, George P; Darviri, Christina

    2011-08-01

    To translate the Perceived Stress Scale (versions PSS-4, -10 and -14) and to assess its psychometric properties in a sample of general Greek population. 941 individuals completed anonymously questionnaires comprising of PSS, the Depression Anxiety and Stress scale (DASS-21 version), and a list of stress-related symptoms. Psychometric properties of PSS were investigated by confirmatory factor analysis (construct validity), Cronbach's alpha (reliability), and by investigating relations with the DASS-21 scores and the number of symptoms, across individuals' characteristics. The two-factor structure of PSS-10 and PSS-14 was confirmed in our analysis. We found satisfactory Cronbach's alpha values (0.82 for the full scale) for PSS-14 and PSS-10 and marginal satisfactory values for PSS-4 (0.69). PSS score exhibited high correlation coefficients with DASS-21 subscales scores, meaning stress (r = 0.64), depression (r = 0.61), and anxiety (r = 0.54). Women reported significantly more stress compared to men and divorced or widows compared to married or singled only. A strong significant (p < 0.001) positive correlation between the stress score and the number of self-reported symptoms was also noted. The Greek versions of the PSS-14 and PSS-10 exhibited satisfactory psychometric properties and their use for research and health care practice is warranted.

  6. Validation Study on the MCC-based Technology

    International Nuclear Information System (INIS)

    Park, Sungkeun; Lee, Dowhan; Kang, Shincheul; Choi, Hyunwoo; Chai, Jangbom

    2006-01-01

    KEPRI and M and D Corporation has developed a methodology, called the NEST I (Non-intrusive Evaluation of Stem Thrust), for determining the stem thrust for a Motor Operated Valve (MOV) based on the motor torque and the stem displacement. The motor torque is determined using another method called NEET (Non-intrusive Evaluation of Electric Torque) which uses the voltage and current data from three phases to obtain the motor torque. The stem displacement is obtained from the voltage and current data along with the nameplate information of the motor, actuator and stem. The motor data (voltage, current and coil current) are measured using MOVIDS (Motor Operated Valve Intelligent Diagnostic System). The motor torque is determined using a NEET algorithm and the stem thrust is calculated using the NEST I method. The goal of this testing was to obtain data from operation of a MOV and to compare the actual measured thrust with the thrust calculated using the NEET / NEST I methods and therefore validate the NEET / NEST I methods

  7. A Finnish validation study of the SCL-90.

    Science.gov (United States)

    Holi, M M; Sammallahti, P R; Aalberg, V A

    1998-01-01

    The Symptom Check-List-90 (SCL-90) is a widely used psychiatric questionnaire which has not yet been validated in Finland. We investigated the utility of the translated version of the SCL-90 in the Finnish population, and set community norms for it. The internal consistency of the original subscales was checked and found to be good. Discriminant function analysis, based on the nine original subscales, showed that the power of the SCL-90 to discriminate between patients and the community is good. Factor analysis of the items of the questionnaire yielded a very strong unrotated first factor, suggesting that a general factor may be present. This together with the fact that high intercorrelations were found between the nine original subscales suggests that the instrument is not multidimensional. The SCL-90 may be useful in a research setting as an instrument for measuring the change in symptomatic distress, or as a screening instrument. The American community norms should be used with caution, as the Finnish community sample scored consistently higher on all subscales.

  8. Study of solute segregation at interfaces using Auger electron spectroscopy

    International Nuclear Information System (INIS)

    White, C.L.

    1984-01-01

    Interfacial segregation, often confined to within a few atomic distances of the interface, can strongly influence the processing and properties of metals and ceramics. The thinness of such solute-enriched regions can cause them to be particularly suitable for study using surface sensitive microanalytical techniques such as Auger electron spectroscopy (AES). The application of AES to studies of interfacial segregation in metals and ceramics is briefly reviewed, and several examples are presented. 43 references, 14 figures

  9. Positron lifetime study of electron-irradiated epoxy resins

    International Nuclear Information System (INIS)

    Suevegh, K.; Vertes, A.; Wojnarovits, L.; Foeldiak, G.; Liszkai, L.; Kajcsos, Zs.

    1990-01-01

    Two bisphenol-A type epoxy resins were irradiated by electron beam and studied afterwards by positron lifetime spectroscopy. An interesting result is that despite of the considerable amount of free-radicals, no inhibition of positronium formation was observed in the two epoxies. Nevertheless, several serious differences were detected between the studied polymers. The results suggest that the radiation-resistant properties of epoxies depend strongly on the amount of the curing agent. (author) 8 refs.; 2 figs

  10. Theoretical study of the interplay of electron-electron interaction and disorder

    International Nuclear Information System (INIS)

    Brezini, A.; Behilil, S.

    1988-10-01

    A disordered Hubbard model with diagonal disorder is used to investigate the electron localization effects associated with both disorder and electron-electron interaction. Extensive results are reported on the ground state properties and compared to other theories. Two regimes have been found: when the electron-electron interaction u is greater than the disorder parameter w and when u < w. (author). 18 refs, 4 figs

  11. Study of warm dense plasma electronic dynamics by optical interferometry

    International Nuclear Information System (INIS)

    Deneuville, F.

    2013-01-01

    The Warm Dense Matter (WDM) regime is characterised by a density close to the solid density and an electron temperature close to the Fermi temperature. In this work, the nonequilibrium Warm Dense Matter is studied during the solid to liquid phase transition induced by an ultra short laser interacting with a solid. A 30 femtosecond time resolution pump-probe experiment (FDI) is set up, yielding to the measurement of the heated sample complex reflectivity for both S and P polarisation. We have determined a criterion based on the measured reflectivities, which permits to control the interface shape of the probed matter. For pump laser fluences around 1 J/cm 2 , the hydrodynamics of the heated matter is studied and experimental results are compared to the two-temperatures code ESTHER. Furthermore, the evolution of the dielectric function at 800 nm and 400 nm is inferred from our measurements on a sub-picosecond time-scale. Within the Drude-Lorentz model for the conduction electrons, the dielectric function yields information such as ionisation state, electronic temperature and electron collision frequency. (author) [fr

  12. Silicon passivation study under low energy electron irradiation conditions

    International Nuclear Information System (INIS)

    Cluzel, R.

    2010-01-01

    Backside illuminated thinned CMOS (Complementary Metal Oxide Semiconductor) imaging system is a technology developed to increase the signal to noise ratio and the sensibility of such sensors. This configuration is adapted to the electrons detection from the energy range of [1 - 12 keV]. The impinging electron creates by multiplication several hundreds of secondary electrons close to the surface. A P ++ highly-doped passivation layer of the rear face is required to reduce the secondary electron surface recombination rate. Thanks to the potential barrier induced by the P ++ layer, the passivation layer increases the collected charges number and so the sensor collection gain. The goal of this study is to develop some experimental methods in order to determine the effect of six different passivation processes on the collection gain. Beforehand, the energy profile deposited by an incident electron is studied with the combination of Monte-Carlo simulations and some analytical calculations. The final collection gain model shows that the mirror effect from the passivation layer is a key factor at high energies whereas the passivation layer has to be as thin as possible at low energies. A first experimental setup which consists in irradiating P ++ /N large diodes allows to study the passivation process impacts on the surface recombinations. Thanks to a second setup based on a single event upset directly on thinned CMOS sensor, passivation techniques are discriminated in term of mirror effect and the implied spreading charges. The doping atoms activation laser annealing is turn out to be a multiplication gain inhomogeneity source impacting directly the matrix uniformity. (author)

  13. Study of the electronic structure of pure aluminium, aluminium oxide and nitride by spectroscopy of electrons excited under electronic and photonic bombardment (X and UV)

    International Nuclear Information System (INIS)

    Gautier-Soyer, Martine

    1985-01-01

    This research thesis reports the use of electron spectroscopy with electrons excited under electronic or photonic (X or UV) bombardment for the study of electronic state density of aluminium, aluminium oxide (Al 2 O 3 ) and aluminium nitride (AlN). The objective is to get an insight into phenomena related to technological problems of adherence, wear, lubrication, corrosion or breakdown met in metals, insulators and semiconductors. The author highlighted the presence of occupied surface states on Al(111) and Al(100), and electronic levels localised in the forbidden band of Al 2 O 3 and AlN, induced by structural defects which promote surface reactivity [fr

  14. Electrochemical impedance spectroscopy for study of electronic structure in disordered organic semiconductors—Possibilities and limitations

    Science.gov (United States)

    Schauer, F.; Nádaždy, V.; Gmucová, K.

    2018-04-01

    There is potential in applying conjugated polymers in novel organic optoelectronic devices, where a comprehensive understanding of the fundamental processes and energetics involved during transport and recombination is still lacking, limiting further device optimization. The electronic transport modeling and its optimization need the energy distribution of transport and defect states, expressed by the energy distribution of the Density of States (DOS) function, as input/comparative parameters. We present the Energy Resolved-Electrochemical Impedance Spectroscopy (ER-EIS) method for the study of transport and defect electronic states in organic materials. The method allows mapping over unprecedentedly wide energy and DOS ranges. The ER-EIS spectroscopic method is based on the small signal interaction between the surface of the organic film and the liquid electrolyte containing reduction-oxidation (redox) species, which is similar to the extraction of an electron by an acceptor and capture of an electron by a donor at a semiconductor surface. The desired DOS of electronic transport and defect states can be derived directly from the measured redox response signal to the small voltage perturbation at the instantaneous position of the Fermi energy, given by the externally applied voltage. The theory of the ER-EIS method and conditions for its validity for solid polymers are presented in detail. We choose four case studies on poly(3-hexylthiophene-2,5-diyl) and poly[methyl(phenyl)silane] to show the possibilities of the method to investigate the electronic structure expressed by DOS of polymers with a high resolution of about 6 orders of magnitude and in a wide energy range of 6 eV.

  15. Reporting to Improve Reproducibility and Facilitate Validity Assessment for Healthcare Database Studies V1.0

    NARCIS (Netherlands)

    Wang, Shirley V.; Schneeweiss, Sebastian; Berger, Marc L.; Brown, Jeffrey; de Vries, Frank; Douglas, Ian; Gagne, Joshua J.; Gini, Rosa; Klungel, Olaf; Mullins, C. Daniel; Nguyen, Michael D.; Rassen, Jeremy A.; Smeeth, Liam; Sturkenboom, Miriam C J M

    2017-01-01

    Purpose: Defining a study population and creating an analytic dataset from longitudinal healthcare databases involves many decisions. Our objective was to catalogue scientific decisions underpinning study execution that should be reported to facilitate replication and enable assessment of validity

  16. Reporting to Improve Reproducibility and Facilitate Validity Assessment for Healthcare Database Studies V1.0

    NARCIS (Netherlands)

    Wang, Shirley V.; Schneeweiss, Sebastian; Berger, Marc L.; Brown, Jeffrey; de Vries, Frank|info:eu-repo/dai/nl/303546670; Douglas, Ian; Gagne, Joshua J.; Gini, Rosa; Klungel, Olaf|info:eu-repo/dai/nl/181447649; Mullins, C. Daniel; Nguyen, Michael D.; Rassen, Jeremy A.; Smeeth, Liam; Sturkenboom, Miriam C J M

    2017-01-01

    Purpose Defining a study population and creating an analytic dataset from longitudinal healthcare databases involves many decisions. Our objective was to catalogue scientific decisions underpinning study execution that should be reported to facilitate replication and enable assessment of validity of

  17. Electron and photon impact studies of CF3I

    International Nuclear Information System (INIS)

    Mason, N.J.; Eden, S.; Limao Vieire, P.; Kendall, P.; Pathak, S.; Dawes, A.; Tegeder, P.; Kitajima, M.; Okamoto, M.; Tanaka, H.; Samukawa, S.; Cho, H.; Hoffmann, S.

    2002-01-01

    The manufacture of ultra-large-scale-integrated circuits, requires a well collimated, specially uniform, high density plasma source operating under low pressure conditions. The main feed gases used are perfluorocarbons, however these are also strong greenhouse gases, therefore must be replaced by alternative compounds with low global warming potentials. CF 3 I is one possible replacement, due to its high photolysis rate, is expected to have a very short lifetime in the atmosphere. It is also predicted to be able to produced high yields of CF 3 radicals in any etching plasma, since its weak C - I bond should be possible to break by direct electron impact. Prior adapting existing industrial plasma reactors to use CF 3 I, it is necessary to run simulations of the reactant plasma, requiring a detailed database of the electron interactions with the feed gases, however such CF 3 I data does not exist. Thus an exhaustive series of experiments to measure elastic and inelastic scattering from CF 3 I including a study of its electronic state spectroscopy using photon absorption and electron scattering techniques were performed. Electron energy loss spectroscopy (EELS) and photo-absorption spectroscopy were employed. A comprehensive set of differential cross sections for the elastic scattering CF 3 I over the impact energy region from 1.5 to 60 eV for scattering angles between 20 and 130 were compiled. The photo-absorption spectrum is characterized by three regions, the first is a very weak continuum around centered about 4.7 eV; the second consists of four prominent band structures observed around 7.4, 8.1, 9.0 and 9.8 eV, respectively, containing vibrational structure from 7 to 10 eV; the third (above the ionization potentials) could only be studied by using EELS and additional broad peaks were observed. (nevyjel)

  18. Evaluating the Social Validity of the Early Start Denver Model: A Convergent Mixed Methods Study

    Science.gov (United States)

    Ogilvie, Emily; McCrudden, Matthew T.

    2017-01-01

    An intervention has social validity to the extent that it is socially acceptable to participants and stakeholders. This pilot convergent mixed methods study evaluated parents' perceptions of the social validity of the Early Start Denver Model (ESDM), a naturalistic behavioral intervention for children with autism. It focused on whether the parents…

  19. Measuring Students' Writing Ability on a Computer-Analytic Developmental Scale: An Exploratory Validity Study

    Science.gov (United States)

    Burdick, Hal; Swartz, Carl W.; Stenner, A. Jackson; Fitzgerald, Jill; Burdick, Don; Hanlon, Sean T.

    2013-01-01

    The purpose of the study was to explore the validity of a novel computer-analytic developmental scale, the Writing Ability Developmental Scale. On the whole, collective results supported the validity of the scale. It was sensitive to writing ability differences across grades and sensitive to within-grade variability as compared to human-rated…

  20. QUOTAC: QUestionnaire On day and night Time respiratory symptoms in Asthmatic Children -- a validity study

    NARCIS (Netherlands)

    van Zaane, B.; Droog, R. P.; Stouthard, M. E. A.; van Aalderen, W. M. C.

    2007-01-01

    The aim of this study was to validate the QUOTAC, a questionnaire on day and night time respiratory symptoms in asthmatic children. Validity was examined by measuring agreement between the QUOTAC and a self-report diary in children aged 6 to 16 years, divided in an asthma group and a control group.

  1. Clinical prediction models for bronchopulmonary dysplasia: a systematic review and external validation study

    NARCIS (Netherlands)

    Onland, Wes; Debray, Thomas P.; Laughon, Matthew M.; Miedema, Martijn; Cools, Filip; Askie, Lisa M.; Asselin, Jeanette M.; Calvert, Sandra A.; Courtney, Sherry E.; Dani, Carlo; Durand, David J.; Marlow, Neil; Peacock, Janet L.; Pillow, J. Jane; Soll, Roger F.; Thome, Ulrich H.; Truffert, Patrick; Schreiber, Michael D.; van Reempts, Patrick; Vendettuoli, Valentina; Vento, Giovanni; van Kaam, Anton H.; Moons, Karel G.; Offringa, Martin

    2013-01-01

    Bronchopulmonary dysplasia (BPD) is a common complication of preterm birth. Very different models using clinical parameters at an early postnatal age to predict BPD have been developed with little extensive quantitative validation. The objective of this study is to review and validate clinical

  2. A Cross-Validation Study of Police Recruit Performance as Predicted by the IPI and MMPI.

    Science.gov (United States)

    Shusman, Elizabeth J.; And Others

    Validation and cross-validation studies were conducted using the Minnesota Multiphasic Personality Inventory (MMPI) and Inwald Personality Inventory (IPI) to predict job performance for 698 urban male police officers who completed a six-month training academy. Job performance criteria evaluated included absence, lateness, derelictions, negative…

  3. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-12-01

    Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population. [JCBPR 2013; 2(3.000: 156-161

  4. Validating the Center for Epidemiological Studies Depression Scale for Children in Rwanda

    Science.gov (United States)

    Betancourt, Theresa; Scorza, Pamela; Meyers-Ohki, Sarah; Mushashi, Christina; Kayiteshonga, Yvonne; Binagwaho, Agnes; Stulac, Sara; Beardslee, William R.

    2012-01-01

    Objective: We assessed the validity of the Center for Epidemiological Studies Depression Scale for Children (CES-DC) as a screen for depression in Rwandan children and adolescents. Although the CES-DC is widely used for depression screening in high-income countries, its validity in low-income and culturally diverse settings, including sub-Saharan…

  5. Validation of Spherically Symmetric Inversion by Use of a Tomographically Reconstructed Three-Dimensional Electron Density of the Solar Corona

    Science.gov (United States)

    Wang, Tongjiang; Davila, Joseph M.

    2014-01-01

    Determining the coronal electron density by the inversion of white-light polarized brightness (pB) measurements by coronagraphs is a classic problem in solar physics. An inversion technique based on the spherically symmetric geometry (spherically symmetric inversion, SSI) was developed in the 1950s and has been widely applied to interpret various observations. However, to date there is no study of the uncertainty estimation of this method. We here present the detailed assessment of this method using a three-dimensional (3D) electron density in the corona from 1.5 to 4 solar radius as a model, which is reconstructed by a tomography method from STEREO/COR1 observations during the solar minimum in February 2008 (Carrington Rotation, CR 2066).We first show in theory and observation that the spherically symmetric polynomial approximation (SSPA) method and the Van de Hulst inversion technique are equivalent. Then we assess the SSPA method using synthesized pB images from the 3D density model, and find that the SSPA density values are close to the model inputs for the streamer core near the plane of the sky (POS) with differences generally smaller than about a factor of two; the former has the lower peak but extends more in both longitudinal and latitudinal directions than the latter. We estimate that the SSPA method may resolve the coronal density structure near the POS with angular resolution in longitude of about 50 deg. Our results confirm the suggestion that the SSI method is applicable to the solar minimum streamer (belt), as stated in some previous studies. In addition, we demonstrate that the SSPA method can be used to reconstruct the 3D coronal density, roughly in agreement with the reconstruction by tomography for a period of low solar activity (CR 2066). We suggest that the SSI method is complementary to the 3D tomographic technique in some cases, given that the development of the latter is still an ongoing research effort.

  6. ELECTRONIC RETAILING IN MACEDONIA-CASE STUDY OF OHRID REGION

    Directory of Open Access Journals (Sweden)

    MARGARITA JANESKA

    2017-04-01

    Full Text Available With electronic retailing that offers the possibility of direct sales, is no longer need expensive business premises, or paying high rents, or employing a number of vendors. There is also the possibility of selling to final consumers in any geographical region in different countries of the world by establishing instant communication, through presenting an interactive multimedia catalog that can offer numerous information то the customers. However, on the other hand, sales through the Internet can appear certain problems. Many potential buyers in the world still do not use the Internet, others don't have fast connections, others do not speak good English, also it requires the existence of trust between both parties, buyer and seller, as well as security in the execution of transactions. The aim of this paper is to treat electronic retailing in Macedonia which is becoming more popular as worldwide, especially in developed parts of the world like the US and Europe. Macedonian companies are increasingly applying electronic method of sale and communication with customers. The number of Internet users and on-line purchase is rapidly expanding what undoubtedly indicates that there is potential for advancement in this field. Also in this paper will be presented a case study where will be analyzed the current state for development of electronic retailing in Macedonia, especially region of Ohrid.

  7. HOSPITAL INFORMATION SYSTEMS: A STUDY OF ELECTRONIC PATIENT RECORDS

    Directory of Open Access Journals (Sweden)

    Pedro Luiz Cortês

    2011-05-01

    Full Text Available The importance of patient records, also known as medical records, is related to different needs and objectives, as they constitute permanent documents on the health of patients. With the advancement of information technologies and systems, patient records can be stored in databases, resulting in a positive impact on patient care. Based on these considerations, a research question that arises is “what are the benefits and problems that can be seen with the use of electronic versions of medical records?” This question leads to the formulation of the following hypothesis: although problems can be identified during the process of using electronic record systems, the benefits outweigh the difficulties, thereby justifying their use. To respond to the question and test the presented hypothesis, a research study was developed with users of the same electronic record system, consisting of doctors, nurses, and administrative personnel in three hospitals located in the city of São Paulo, Brazil. The results show that, despite some problems in their usage, the benefits of electronic patient records outweigh possible disadvantages.

  8. Studies of electron and proton isochoric heating for fast ignition

    International Nuclear Information System (INIS)

    Mackinnon, A; Key, M; Akli, K; Beg, F; Clarke, R; Clarke, D; Chen, M; Chung, H; Chen, S; Freeman, R; Green, J; Gu, P; Gregori, G; Highbarger, K; Habara, H; Hatchett, S; Hey, D; Heathcote, R; Hill, J; King, J; Kodama, R; Koch, J; Lancaster, K; Langdon, B; Murphy, C; Norreys, P; Neely, D; Nakatsutsumi, M; Nakamura, H; Patel, N; Patel, P; Pasley, J; Snavley, R; Stephens, R; Stoeckl, C; Foord, M; Tabak, M; Theobald, W; Storm, M; Tanaka, K; Tempo, M; Toley, M; Town, R; Wilks, S; VanWoerkom, L; Weber, R; Yabuuchi, T; Zhang, B

    2006-01-01

    Isochoric heating of inertially confined fusion plasmas by laser driven MeV electrons or protons is an area of great topical interest in the inertial confinement fusion community, particularly with respect to the fast ignition (FI) proposal to use this technique to initiate burn in a fusion capsule. Experiments designed to investigate electron isochoric heating have measured heating in two limiting cases of interest to fast ignition, small planar foils and hollow cones. Data from Cu Kα fluorescence, crystal x-ray spectroscopy of Cu K shell emission, and XUV imaging at 68eV and 256 eV are used to test PIC and Hybrid PIC modeling of the interaction. Isochoric heating by focused proton beams generated at the concave inside surface of a hemi-shell and from a sub hemi-shell inside a cone have been studied with the same diagnostic methods plus imaging of proton induced Kα. Conversion efficiency to protons has also been measured and modeled. Conclusions from the proton and electron heating experiments will be presented. Recent advances in modeling electron transport and innovative target designs for reducing igniter energy and increasing gain curves will also be discussed

  9. A Complete Reporting of MCNP6 Validation Results for Electron Energy Deposition in Single-Layer Extended Media for Source Energies <= 1-MeV

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hughes, Henry Grady [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-04

    In this paper, we expand on previous validation work by Dixon and Hughes. That is, we present a more complete suite of validation results with respect to to the well-known Lockwood energy deposition experiment. Lockwood et al. measured energy deposition in materials including beryllium, carbon, aluminum, iron, copper, molybdenum, tantalum, and uranium, for both single- and multi-layer 1-D geometries. Source configurations included mono-energetic, mono-directional electron beams with energies of 0.05-MeV, 0.1-MeV, 0.3- MeV, 0.5-MeV, and 1-MeV, in both normal and off-normal angles of incidence. These experiments are particularly valuable for validating electron transport codes, because they are closely represented by simulating pencil beams incident on 1-D semi-infinite slabs with and without material interfaces. Herein, we include total energy deposition and energy deposition profiles for the single-layer experiments reported by Lockwood et al. (a more complete multi-layer validation will follow in another report).

  10. Study of the mass of the electron neutrino in Japan

    International Nuclear Information System (INIS)

    Yasumi, Shinjiro; Maezawa, Hideki

    1996-02-01

    This report describes a study of the mass of the electron neutrino using electron capture in 163 Ho in Japan for the period from 1981 to 1994. This monograph has two purposes, one is to supplement the papers on the mass of the electron neutrino already published by us and another is to make a record on some details of our experiments for future. Electron capture in a nucleus takes place in a rather small space inside an atom, where atomic physics, nuclear physics and particle physics work closely together. Therefore, this study needed an intimate collaboration of atomic physicists, nuclear physicists and particle physicists. In addition, it was necessary for this study to use various fine techniques, including metallurgy, production of 163 Ho activity, micro-analysis by wet chemistry, isotope-dilution mass spectrometry, undulator radiation source technology, the soft X-ray monochromator technology, a counting technique for very intense soft X-rays and so on. As a result, our collaboration consisted of many researchers from various fields as follows; M. Ando, H. Arai, M. Fujioka, N. Hashimoto, H. Ikeda, Y. Inagaki, K. Ishii, K. Itoh, G. Izawa, O. Kawakami, S. Kishimoto, H. Kitamura, H. Maezawa, M. Maruyama, A. Masuda, K. Masumoto, A. Mikuni, T. Mizogawa, T. Mukoyama, F. Ochiai, T. Ohta, T. Omori, G. Rajasekaran, K. Sera, K. Shima, T. Shinozuka, P.M. Stefan, I. Sugai, H. Taketani, M. Yagi, and S. Yasumi. Without such an excellent collaboration, this study would not have been completed. We would like to express our sincere gratitude to Professor T. Sasaki for supporting this study and recommending the undulator beam line of 2.5 GeV Photon Factory Storage Ring as a light source to be used in the experiment. We also would like to thank Dr. A. Yagishita and Dr. Y. Kitajima who are responsible for the BL-2 beamline. Finally we are grateful to Ms. M. Noji for her patient typewriting of manuscripts written by hand. (author)

  11. Electron microscopy studies of materials used for hydrogen storage

    Energy Technology Data Exchange (ETDEWEB)

    Andrei, Carmen M.

    2004-07-01

    Concerns over global warming and air pollution have stimulated the concept of the ''Hydrogen Economy'' and the potential extensive use of hydrogen as an energy carrier. Hydrogen storage in a solid matrix has become one of the promising solutions for vehicular applications. In this study, several transmission electron microscopy (TEM) techniques such as high resolution (HR), electron diffraction, energy dispersive X-ray spectroscopy (EDS), electron energy loss spectroscopy (EELS) and energy-filtered transmission electron microscopy (EFT EM) as well as scanning electron microscopy (SEM) have been used to study the microstructure of materials related to hydrogen storage applications. Some of the results are compared with powder X-ray diffraction (PXD) data. A TbNiAl compound processed by the hydrogenation-disproportionation-desorption-recombination (HDDR) route has been studied using a combination of SEM, TEM and PXD. Information about the variations in the composition and surface topography in both disproportionation and recombination stages is given by the SEM backscattered electrons and secondary electrons images. The crystallites that have undergone the recombination process were found smaller in size. The sodium alanate, NaAIH4 is one of the most promising candidate materials for hydrogen storage. Ti additives are effective at reducing the reaction temperatures and improving the efficiency of the kinetics. The microstructure of NaAlH4 with TiF3 additive has been examined after the initial ball milling and after 15 cycles, using TEM, SEM and EDS. The effect of the additive on particle morphology, grain size and distribution of the phases has been studied. The additive has uneven distribution in the sample after initial ball milling. After 15 cycles, EDS maps show some combination of Ti with the alanate phase. No significant change in grain size of the Na/Al rich particles between the ball milled and 15 cycled sample was observed. The LiAlD4

  12. Electron spectroscopic study of electronic and morphological modifications of the WSe{sub 2} surface induced by Rb adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Jens

    2010-07-20

    The rubidium-covered surface of the semiconducting transition metal dichalcogenide tungsten diselenide (WSe{sub 2}) is examined using photoelectron spectroscopy (PES) and photoemission electron microscopy (PEEM). Adsorbed Rb is known to induce a variety of effects in this system concerning electronic, structural, and mechanical properties. In this work, the surface potential created by charge transfer upon Rb deposition is examined in thermal equilibrium (band bending) and stationary non-equilibrium (surface photovoltage (SPV) effect), which is induced by the absorption of light. It is shown that combined measurements and numerical simulations of the SPV effect as a function of the photon flux can be exploited for the estimation of many material parameters of the system, especially of the unoccupied adsorbate state. Issues of extending a conventional photoelectron spectrometer setup by a secondary light source will be discussed in the context of simulations and calibration measurements. The customization of an existing theoretical model of the SPV effect for the WSe{sub 2}: Rb system is introduced, and a comprehensive validation of the obtained predictions is given in the context of experimental data. In addition, the self-organized formation of Rb domains at room temperature was examined by application of spatially resolved XPS spectroscopy using the PEEM setup at the end station of beamline UE49/PGMa at the BESSY II synchrotron facility. From the obtained results, the arrangement of Rb in surface lattices can be concluded. Furthermore, an X-Ray absorption study of self-organized nanostructure networks, aiming at the chemical characterization, is presented. Based on the interpretation of the examined structures as tension-induced cracks, a statistical approach to analyzing large-scale features was pursued. First accordance with the predictions made by a primitive, mechanical model of crack creation developed here gives gives some evidence for the validity of the

  13. Electron spectroscopic study of electronic and morphological modifications of the WSe2 surface induced by Rb adsorption

    International Nuclear Information System (INIS)

    Buck, Jens

    2010-01-01

    The rubidium-covered surface of the semiconducting transition metal dichalcogenide tungsten diselenide (WSe 2 ) is examined using photoelectron spectroscopy (PES) and photoemission electron microscopy (PEEM). Adsorbed Rb is known to induce a variety of effects in this system concerning electronic, structural, and mechanical properties. In this work, the surface potential created by charge transfer upon Rb deposition is examined in thermal equilibrium (band bending) and stationary non-equilibrium (surface photovoltage (SPV) effect), which is induced by the absorption of light. It is shown that combined measurements and numerical simulations of the SPV effect as a function of the photon flux can be exploited for the estimation of many material parameters of the system, especially of the unoccupied adsorbate state. Issues of extending a conventional photoelectron spectrometer setup by a secondary light source will be discussed in the context of simulations and calibration measurements. The customization of an existing theoretical model of the SPV effect for the WSe 2 : Rb system is introduced, and a comprehensive validation of the obtained predictions is given in the context of experimental data. In addition, the self-organized formation of Rb domains at room temperature was examined by application of spatially resolved XPS spectroscopy using the PEEM setup at the end station of beamline UE49/PGMa at the BESSY II synchrotron facility. From the obtained results, the arrangement of Rb in surface lattices can be concluded. Furthermore, an X-Ray absorption study of self-organized nanostructure networks, aiming at the chemical characterization, is presented. Based on the interpretation of the examined structures as tension-induced cracks, a statistical approach to analyzing large-scale features was pursued. First accordance with the predictions made by a primitive, mechanical model of crack creation developed here gives gives some evidence for the validity of the proposed

  14. Toddler physical activity study: laboratory and community studies to evaluate accelerometer validity and correlates

    Directory of Open Access Journals (Sweden)

    Erin R. Hager

    2016-09-01

    Full Text Available Abstract Background Toddlerhood is an important age for physical activity (PA promotion to prevent obesity and support a physically active lifestyle throughout childhood. Accurate assessment of PA is needed to determine trends/correlates of PA, time spent in sedentary, light, or moderate-vigorous PA (MVPA, and the effectiveness of PA promotion programs. Due to the limited availability of objective measures that have been validated and evaluated for feasibility in community studies, it is unclear which subgroups of toddlers are at the highest risk for inactivity. Using Actical ankle accelerometry, the objectives of this study are to develop valid thresholds, examine feasibility, and examine demographic/ anthropometric PA correlates of MVPA among toddlers from low-income families. Methods Two studies were conducted with toddlers (12–36 months. Laboratory Study (n = 24- Two Actical accelerometers were placed on the ankle. PA was observed using the Child Activity Rating Scale (CARS, prescribed activities. Analyses included device equivalence reliability (correlation: activity counts of two Acticals, criterion-related validity (correlation: activity counts and CARS ratings, and sensitivity/specificity for thresholds. Community Study (n = 277, low-income mother-toddler dyads recruited- An Actical was worn on the ankle for > 7 days (goal >5, 24-h days. Height/weight was measured. Mothers reported demographics. Analyses included frequencies (feasibility and stepwise multiple linear regression (sMLR. Results Laboratory Study- Acticals demonstrated reliability (r = 0.980 and validity (r = 0.75. Thresholds demonstrated sensitivity (86 % and specificity (88 %. Community Study- 86 % wore accelerometer, 69 % had valid data (mean = 5.2 days. Primary reasons for missing/invalid data: refusal (14 % and wear-time ≤2 days (11 %. The MVPA threshold (>2200 cpm yielded 54 min/day. In sMLR, MVPA was associated with age (older

  15. Validation study of a drift-wave turbulence model for CSDX linear plasma device

    Science.gov (United States)

    Vaezi, P.; Holland, C.; Thakur, S. C.; Tynan, G. R.

    2017-09-01

    A validation study of self-regulating drift-wave turbulence/zonal flow dynamics in the Controlled Shear Decorrelation Experiment linear plasma device using Langmuir probe synthetic diagnostics is presented in this paper. We use a set of nonlocal 3D equations, which evolve density, vorticity, and electron temperature fluctuations, and include proper sheath boundary conditions. Nonlinear simulations of these equations are carried out using BOUndary Turbulence (BOUT++) framework. To identify the dominant parametric dependencies of the model, a linear growth rate sensitivity analysis is performed using input parameter uncertainties, which are taken from the experimental measurements. For the direct comparison of nonlinear simulation results to experiment, we use synthetic Langmuir probe diagnostics to generate a set of synthetic ion saturation current and floating potential fluctuations. In addition, comparisons of azimuthal velocities determined via time-delay estimation, and nonlinear energy transfer are shown. We observe a significant improvement of model-experiment agreement relative to the previous 2D simulations. An essential component of this improved agreement is found to be the effect of electron temperature fluctuations on floating potential measurements, which introduces clear amplitude and phase shifts relative to the plasma potential fluctuations in synthetically measured quantities, where the simulations capture the experimental measurements in the core of plasma. However, the simulations overpredict the fluctuation levels at larger radii. Moreover, systematic simulation scans show that the self-generated E × B zonal flows profile is very sensitive to the steepening of density equilibrium profile. This suggests that evolving both fluctuations and equilibrium profiles, along with the inclusion of modest axial variation of radial profiles in the model are needed for further improvement of simulation results against the experimental measurements.

  16. Postponed variety creation: case study in consumer electronics retail

    DEFF Research Database (Denmark)

    Appelqvist, Patrik; Gubi, Ebbe

    2005-01-01

    Purpose – Postponement is known as a way to reduce risk and inventories while still providing high product variety and acceptable response times. The paper is a case study that uses simulation for quantifying these benefits for a consumer electronics company. Design/methodology/approach – Improve...... modular product architecture can be utilised to improve operational supply chain performance.......Purpose – Postponement is known as a way to reduce risk and inventories while still providing high product variety and acceptable response times. The paper is a case study that uses simulation for quantifying these benefits for a consumer electronics company. Design....../methodology/approach – Improvement potential is first evaluated qualitatively through interviews with dealers of the case company. Next, the benefit of postponement is evaluated quantitatively using discrete-event simulation with data from operational ERP systems. The conclusions identify conditions under which postponement...

  17. Measurements of sin2 θ/sub w/ from studies of the elastic scattering of neutrinos by protons and electrons

    International Nuclear Information System (INIS)

    Mann, A.K.

    1986-01-01

    This talk is intended as a brief report on studies of the elastic scattering of neutrinos by protons and electrons. Measurements of the ratios of muon antineutrino and muon neutrino elastic scattering on protons, and the corresponding ratio for elastic scattering on electrons minimize systematic experimental errors, and lead directly to values of the fundamental parameter of the electroweak interaction, the Weinberg Angle, with minimal ambiguity. Accordingly, the principal motivation in carrying out these studies was the desire to obtain and compare precise values of the Weinberg Angle from both the semileptonic and leptonic reactions as still another test of the basic validity of the standard electroweak theory. 10 refs., 11 figs

  18. Study of electronic field emission from large surfaces under static operating conditions and hyper-frequency

    International Nuclear Information System (INIS)

    Luong, M.

    1997-09-01

    The enhanced electronic field emission from large area metallic surfaces lowers performances of industrial devices that have to sustain high electric field under vacuum. Despite of numerous investigations in the past, the mechanisms of such an emission have never been well clarified. Recently, research in our laboratory has pointed out the importance played by conducting sites (particles and protrusions). A refined geometrical model, called superposed protrusions model has been proposed to explain the enhanced emission by local field enhancement. As a logical continuation, the present work aims at testing this model and, in the same time, investigating the means to suppress the emission where it is undesirable. Thus, we have showed: the cause of current fluctuations in a continuous field regime (DC), the identity of emission characteristics (β, A e ) in both radiofrequency (RF) and DC regimes, the effectiveness of a thermal treatment by extern high density electronic bombardment, the effectiveness of a mechanical treatment by high pressure rinsing with ultra pure water, the mechanisms and limits of an in situ RF processing. Furthermore, the electronic emission from insulating particles has also been studied concurrently with a spectral analysis of the associated luminous emission. Finally, the refined geometrical model for conducting sites is reinforced while another model is proposed for some insulating sites. Several emission suppressing treatments has been explored and validated. At last, the characteristic of a RF pulsed field emitted electron beam has been checked for the first time as a possible application of such a field emission. (author)

  19. A study of vibrational relaxation of electronically-excited molecules

    International Nuclear Information System (INIS)

    Datsyuk, V.V.; Izmailov, I.A.; Kochelap, V.A.

    1992-09-01

    The time kinetics of the vibrational relaxation of excimers is studied in the diffusional approximation. Simple formulae for functions of nonstationary vibrational distribution are found for the electronically excited molecules. Some spectral-kinetic dependencies of the excimer luminescence are explained in a new way. The possibilities of the determination of excimer parameters are discussed. The dependence of energetical characteristics of excimer lasers on these parameters is particularly emphasized. (author). 22 refs, 5 figs

  20. Studies of collision dynamics in electron capture processes

    International Nuclear Information System (INIS)

    Hansen, J.P.

    1990-12-01

    This thesis presents some recent development in time-dependent coupled channel methods for one- and two-electron systems. The methods have been applied to detailed studies on several different aspects of charge transfer processes in ion-atom collisions at intermediate to low energies. Measurable quantities, such as partial and total cross sections, partial cross sections in projectile energy gain, orientation and alignment fractions, have been calculated. Confrontation with experiments has in general given good agreement. 29 refs

  1. Studies of collision dynamics in electron capture processes

    International Nuclear Information System (INIS)

    Hansen, J.P.

    1989-12-01

    The thesis presents some recent development in time-dependent coupled channel methods for one- and two-electron systems. The methods have been applied to detailed studies on several different aspects of charge transfer processes in ion-atom collisions at intermediate to low energies. Measurable quantities, such as partial and total cross sections, partial cross sections in projectile energy gain, orientation and alignment fractions, have been calculated. Confrontation with experiments has in general given good agreement. 14 refs., 2 figs

  2. Structural studies of glasses by transmission electron microscopy and electron diffraction

    International Nuclear Information System (INIS)

    Kashchieva, E.P.

    1997-01-01

    The purpose of this work is to present information about the applications of transmission electron microscopy (TEM) and electron diffraction (ED) for structural investigations of glasses. TEM investigations have been carried out on some binary and on a large number of ternary borate-telluride systems where glass-forming oxides, oxides of transitional elements and modified oxides of elements from I, II and III groups in the periodic table, are used as third component. The large experimental data given by TEM method allows the fine classification of the micro-heterogeneities. A special case of micro-heterogeneous structure with technological origin occurs near the boundary between the 2 immiscible liquids obtained at macro-phase separation. TEM was also used for the direct observation of the glass structure and we have studied the nano-scale structure of borate glasses obtained at slow and fast cooling of the melts. The ED possesses advantages for analysis of amorphous thin films or micro-pastilles and it is a very useful technique for study in materials containing simultaneously light and heavy elements. A comparison between the possibilities of the 3 diffraction techniques (X-ray diffraction, neutron diffraction and ED) is presented

  3. How valid are claims for synergy in published clinical studies?

    Science.gov (United States)

    Ocana, A; Amir, E; Yeung, C; Seruga, B; Tannock, I F

    2012-08-01

    Clinical trials evaluating drug combinations are often stimulated by claims of synergistic interactions in preclinical models. Overuse or misuse of the term synergy could lead to poorly designed clinical studies. We searched PubMed using the terms 'synergy' or 'synergistic' and 'cancer' to select articles published between 2006 and 2010. Eligible studies were those that referred to synergy in preclinical studies to justify a drug combination evaluated in a clinical trial. Eighty-six clinical articles met eligibility criteria and 132 preclinical articles were cited in them. Most of the clinical studies were phase I (43%) or phase II trials (56%). Appropriate methods to evaluate synergy in preclinical studies included isobologram analysis in 18 studies (13.6%) and median effect in 10 studies (7.6%). Only 26 studies using animal models (39%) attempted to evaluate therapeutic index. There was no association between the result of the clinical trial and the use of an appropriate method to evaluate synergy (P=0.25, chi-squared test). Synergy is cited frequently in phase I and phase II studies to justify the evaluation of a specific drug combination. Inappropriate methods for evaluation of synergy and poor assessment of therapeutic index have been used in most preclinical articles.

  4. Electronic conductivity studies on oxyhalide glasses containing TMO

    Energy Technology Data Exchange (ETDEWEB)

    Vijayatha, D. [R& D Center, Bharatiar University, Coimbatore, Tamil Nadu (India); Department of Physics, Gurunanak Institute of Technology, Hyderabad -040 (India); Viswanatha, R. [Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560012 (India); Sujatha, B. [Department of Electronics and Communcation, MSRIT, Bangalore 560054 (India); Narayana Reddy, C., E-mail: nivetejareddy@gmail.com [Department of Physics, Sree Siddaganga College of Arts, Science and Commerce, Tumkur 572102 (India)

    2016-05-06

    Microwave-assisted synthesis is cleaner, more economical and much faster than conventional methods. The development of new routes for the synthesis of solid materials is an integral part of material science and technology. The electronic conductivity studies on xPbCl{sub 2} – 60 PbO – (40-x) V{sub 2}O{sub 5} (1 ≥ x ≤ 10) glass system has been carried out over a wide range of composition and temperature (300 K to 423 K). X-ray diffraction study confirms the amorphous nature of the samples. The Scanning electron microscopic studies reveal the formation of cluster like morphology in PbCl{sub 2} containing glasses. The d.c conductivity exhibits Arrhenius behaviour and increases with V{sub 2}O{sub 5} concentration. Analysis of the results is interpreted in view Austin-Mott’s small polaron model of electron transport. Activation energies calculated using regression analysis exhibit composition dependent trend and the variation is explained in view of the structure of lead-vanadate glass.

  5. Digital technique for the study of narrow structure in electron-atom and electron-molecule scattering

    International Nuclear Information System (INIS)

    Paske, W.C.; Shadfar, S.; Lorentz, S.R.; Steph, N.C.; Golden, D.E.

    1981-01-01

    A digital technique has been developed which allows the study of narrow structure in total electron-atom and electron-molecule scattering cross sections without requiring a highly monoenergetic electron beam, modulation of the electron gun, or phase sensitive detection. The electron current transmitted through a gas cell is digitized as the electron energy is stepped by ΔE through the energy range of interest. A transmitted electron difference signal is then obtained using a computer. As examples of this technique, the difference spectra are presented for He near 19.35 eV and for N 2 for the energy range from 10.3 to 15.0 eV. In the present case an instrumental resolution of 30 meV FWHM has been obtained

  6. Design and Implementation Content Validity Study: Development of an instrument for measuring Patient-Centered Communication

    Directory of Open Access Journals (Sweden)

    Vahid Zamanzadeh

    2015-06-01

    Full Text Available ABSTRACT Introduction: The importance of content validity in the instrument psychometric and its relevance with reliability, have made it an essential step in the instrument development. This article attempts to give an overview of the content validity process and to explain the complexity of this process by introducing an example. Methods: We carried out a methodological study conducted to examine the content validity of the patient-centered communication instrument through a two-step process (development and judgment. At the first step, domain determination, sampling (item generation and instrument formation and at the second step, content validity ratio, content validity index and modified kappa statistic was performed. Suggestions of expert panel and item impact scores are used to examine the instrument face validity. Results: From a set of 188 items, content validity process identified seven dimensions includes trust building (eight items, informational support (seven items, emotional support (five items, problem solving (seven items, patient activation (10 items, intimacy/friendship (six items and spirituality strengthening (14 items. Content validity study revealed that this instrument enjoys an appropriate level of content validity. The overall content validity index of the instrument using universal agreement approach was low; however, it can be advocated with respect to the high number of content experts that makes consensus difficult and high value of the S-CVI with the average approach, which was equal to 0.93. Conclusion: This article illustrates acceptable quantities indices for content validity a new instrument and outlines them during design and psychometrics of patient-centered communication measuring instrument.

  7. Electron and impurity transport studies in the TCV Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, D.

    2013-05-15

    In this thesis electron and impurity transport are studied in the Tokamak à Configuration Variable (TCV) located at CRPP-EPFL in Lausanne. Understanding particle transport is primordial for future nuclear fusion power plants. Modeling of experiments in many specific plasma scenarios can help to understand the common elements of the physics at play and to interpret apparently contradictory experiments on the same machine and across different machines. The first part of this thesis deals with electron transport in TCV high confinement mode plasmas. It was observed that the electron density profile in these plasmas flatten when intense electron heating is applied, in contrast to observations on other machines where the increase of the profile peakedness was reported. It is shown with quasi-linear gyrokinetic simulations that this effect, usually interpreted as collisionality dependence, stems from the combined effect of many plasma parameters. The influence of the collisionality, electron to ion temperature ratio, the ratio of temperature gradients, and the Ware-pinch are studied with detailed parameter scans. It is shown that the complex interdependence of the various plasma parameters is greatly simplified when the simulation results are interpreted as a function of the average frequency of the main modes contributing to radial transport. In this way the model is able to explain the experimental results. It was also shown that the same basic understanding is at play in L-modes, H-modes and electron internal transport barriers. The second part of the thesis is devoted to impurity transport. A multi-purpose gas injection system is developed, commissioned and calibrated. It is shown that the system is capable of massive gas injections to provoke disruptions and delivering small puffs of gaseous impurities for perturbative transport experiments. This flexible tool is exploited in a series of impurity transport measurements with argon and neon injections. The impurities

  8. Electron and impurity transport studies in the TCV Tokamak

    International Nuclear Information System (INIS)

    Wagner, D.

    2013-05-01

    In this thesis electron and impurity transport are studied in the Tokamak à Configuration Variable (TCV) located at CRPP-EPFL in Lausanne. Understanding particle transport is primordial for future nuclear fusion power plants. Modeling of experiments in many specific plasma scenarios can help to understand the common elements of the physics at play and to interpret apparently contradictory experiments on the same machine and across different machines. The first part of this thesis deals with electron transport in TCV high confinement mode plasmas. It was observed that the electron density profile in these plasmas flatten when intense electron heating is applied, in contrast to observations on other machines where the increase of the profile peakedness was reported. It is shown with quasi-linear gyrokinetic simulations that this effect, usually interpreted as collisionality dependence, stems from the combined effect of many plasma parameters. The influence of the collisionality, electron to ion temperature ratio, the ratio of temperature gradients, and the Ware-pinch are studied with detailed parameter scans. It is shown that the complex interdependence of the various plasma parameters is greatly simplified when the simulation results are interpreted as a function of the average frequency of the main modes contributing to radial transport. In this way the model is able to explain the experimental results. It was also shown that the same basic understanding is at play in L-modes, H-modes and electron internal transport barriers. The second part of the thesis is devoted to impurity transport. A multi-purpose gas injection system is developed, commissioned and calibrated. It is shown that the system is capable of massive gas injections to provoke disruptions and delivering small puffs of gaseous impurities for perturbative transport experiments. This flexible tool is exploited in a series of impurity transport measurements with argon and neon injections. The impurities

  9. Electron paramagnetic resonance study on n-type electron-irradiated 3C-SiC

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, P; Rabia, K; Son, N T; Janzen, E [Department of Physics, Chemistry and Biology, Linkoeping University, SE-581 83 Linkoeping (Sweden); Ohshima, T; Morishita, N; Itoh, H [Japan Atomic Energy Research Institute, Takasaki 370-1292 (Japan); Isoya, J [University of Tsukuba, Tsukuba 305-8550 (Japan)], E-mail: paca@ifm.liu.se

    2008-03-15

    Electron Paramagnetic Resonance (EPR) was used to study defects in n-type 3C-SiC films irradiated by 3-MeV electrons at room temperature with a dose of 2x10{sup 18} cm{sup -2}. After electron irradiation, two new EPR spectra with an effective spin S = 1, labeled L5 and L6, were observed. The L5 center has C{sub 3v} symmetry with g = 2.004 and a fine-structure parameter D = 436.5x10{sup -4} cm{sup -1}. The L5 spectrum was only detected under light illumination and it could not be detected after annealing at {approx}550{sup 0}C. The principal z-axis of the D tensor is parallel to the <111>-directions, indicating the location of spins along the Si-C bonds. Judging from the symmetry and the fact that the signal was detected under illumination in n-type material, the L5 center may be related to the divacancy in the neutral charge state. The L6 center has a C{sub 2v}-symmetry with an isotropic g-value of g = 2.003 and the fine structure parameters D = 547.7x10{sup -4} cm{sup -1} and E = 56.2x10{sup -4} cm{sup -1}. The L6 center disappeared after annealing at a rather low temperature ({approx}200 deg. C), which is substantially lower than the known annealing temperatures for vacancy-related defects in 3C-SiC. This highly mobile defect may be related to carbon interstitials.

  10. C library for topological study of the electronic charge density.

    Science.gov (United States)

    Vega, David; Aray, Yosslen; Rodríguez, Jesús

    2012-12-05

    The topological study of the electronic charge density is useful to obtain information about the kinds of bonds (ionic or covalent) and the atom charges on a molecule or crystal. For this study, it is necessary to calculate, at every space point, the electronic density and its electronic density derivatives values up to second order. In this work, a grid-based method for these calculations is described. The library, implemented for three dimensions, is based on a multidimensional Lagrange interpolation in a regular grid; by differentiating the resulting polynomial, the gradient vector, the Hessian matrix and the Laplacian formulas were obtained for every space point. More complex functions such as the Newton-Raphson method (to find the critical points, where the gradient is null) and the Cash-Karp Runge-Kutta method (used to make the gradient paths) were programmed. As in some crystals, the unit cell has angles different from 90°, the described library includes linear transformations to correct the gradient and Hessian when the grid is distorted (inclined). Functions were also developed to handle grid containing files (grd from DMol® program, CUBE from Gaussian® program and CHGCAR from VASP® program). Each one of these files contains the data for a molecular or crystal electronic property (such as charge density, spin density, electrostatic potential, and others) in a three-dimensional (3D) grid. The library can be adapted to make the topological study in any regular 3D grid by modifying the code of these functions. Copyright © 2012 Wiley Periodicals, Inc.

  11. Measuring Nutrition Literacy in Spanish-Speaking Latinos: An Exploratory Validation Study.

    Science.gov (United States)

    Gibbs, Heather D; Camargo, Juliana M T B; Owens, Sarah; Gajewski, Byron; Cupertino, Ana Paula

    2017-11-21

    Nutrition is important for preventing and treating chronic diseases highly prevalent among Latinos, yet no tool exists for measuring nutrition literacy among Spanish speakers. This study aimed to adapt the validated Nutrition Literacy Assessment Instrument for Spanish-speaking Latinos. This study was developed in two phases: adaptation and validity testing. Adaptation included translation, expert item content review, and interviews with Spanish speakers. For validity testing, 51 participants completed the Short Assessment of Health Literacy-Spanish (SAHL-S), the Nutrition Literacy Assessment Instrument in Spanish (NLit-S), and socio-demographic questionnaire. Validity and reliability statistics were analyzed. Content validity was confirmed with a Scale Content Validity Index of 0.96. Validity testing demonstrated NLit-S scores were strongly correlated with SAHL-S scores (r = 0.52, p internal consistency was excellent (Cronbach's α = 0.92). The NLit-S demonstrates validity and reliability for measuring nutrition literacy among Spanish-speakers.

  12. Validation of a zero-dimensional model for prediction of NOx and engine performance for electronically controlled marine two-stroke diesel engines

    International Nuclear Information System (INIS)

    Scappin, Fabio; Stefansson, Sigurður H.; Haglind, Fredrik; Andreasen, Anders; Larsen, Ulrik

    2012-01-01

    The aim of this paper is to derive a methodology suitable for energy system analysis for predicting the performance and NO x emissions of marine low speed diesel engines. The paper describes a zero-dimensional model, evaluating the engine performance by means of an energy balance and a two zone combustion model using ideal gas law equations over a complete crank cycle. The combustion process is divided into intervals, and the product composition and flame temperature are calculated in each interval. The NO x emissions are predicted using the extended Zeldovich mechanism. The model is validated using experimental data from two MAN B and W engines; one case being data subject to engine parameter changes corresponding to simulating an electronically controlled engine; the second case providing data covering almost all model input and output parameters. The first case of validation suggests that the model can predict specific fuel oil consumption and NO x emissions within the 95% confidence intervals given by the experimental measurements. The second validation confirms the capability of the model to match measured engine output parameters based on measured engine input parameters with a maximum 5% deviation. - Highlights: ► A fast realistic model of a marine two-stroke low speed diesel engine was derived. ► The model is fast and accurate enough for future complex energy systems analysis. ► The effects of engine tuning were validated with experimental tests. ► The model was validated while constrained by experimental input and output data.

  13. Electronic Document Management: A Human Resource Management Case Study

    Directory of Open Access Journals (Sweden)

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  14. Study of SPM tolerances of electronically compensated DML based systems.

    Science.gov (United States)

    Papagiannakis, I; Klonidis, D; Birbas, Alexios N; Kikidis, J; Tomkos, I

    2009-05-25

    This paper experimentally investigates the effectiveness of electronic dispersion compensation (EDC) for signals limited by self phase modulation (SPM) and various dispersion levels. The sources considered are low-cost conventional directly modulated lasers (DMLs), fabricated for operation at 2.5 Gb/s but modulated at 10 Gb/s. Performance improvement is achieved by means of electronic feed-forward and decision-feedback equalization (FFE/DFE) at the receiver end. Experimental studies consider both transient and adiabatic chirp dominated DMLs sources. The improvement is evaluated in terms of required optical signal-to-noise ratio (ROSNR) for bit-error-rate (BER) values of 10(-3) versus launch power over uncompensated links of standard single mode fiber (SSMF).

  15. Microscopical Studies of Structural and Electronic Properties of Semiconductors

    CERN Multimedia

    2002-01-01

    The electronic and structural properties of point defects in semiconductors, e.g. radiation defects, impurities or passivating defects can excellently be studied by the hyperfine technique of Perturbed Angular Correlation (PAC). The serious limitation of this method, the small number of chemically different radioactive PAC probe atoms can be widely overcome by means of ISOLDE. Providing shortliving isotopes, which represent common dopants as well as suitable PAC probe atoms, the ISOLDE facility enables a much broader application of PAC to problems in semiconductor physics.\\\\ Using the probe atom $^{111m}$ Cd , the whole class of III-V compounds becomes accessible for PAC investigations. First successful experiments in GaAs, InP and GaP have been performed, concerning impurity complex formation and plasma induced defects. In Si and Ge, the electronic properties~-~especially their influence on acceptor-donor interaction~-~could be exemplarily st...

  16. High Pressure X-ray Absorption Studies on Correlated-Electron Systems

    International Nuclear Information System (INIS)

    Cornelius, Andrew L.

    2016-01-01

    This project used high pressure to alter the electron-electron and electron-lattice interactions in rare earth and actinide compounds. Knowledge of these properties is the starting points for a first-principles understanding of electronic and electronically related macroscopic properties. The research focused on a systematic study of x-ray absorption measurements on rare earth and actinide compounds.

  17. Transmission Electron Microscopy Studies of Electron-Selective Titanium Oxide Contacts in Silicon Solar Cells

    KAUST Repository

    Ali, Haider

    2017-08-15

    In this study, the cross-section of electron-selective titanium oxide (TiO2) contacts for n-type crystalline silicon solar cells were investigated by transmission electron microscopy. It was revealed that the excellent cell efficiency of 21.6% obtained on n-type cells, featuring SiO2/TiO2/Al rear contacts and after forming gas annealing (FGA) at 350°C, is due to strong surface passivation of SiO2/TiO2 stack as well as low contact resistivity at the Si/SiO2/TiO2 heterojunction. This can be attributed to the transformation of amorphous TiO2 to a conducting TiO2-x phase. Conversely, the low efficiency (9.8%) obtained on cells featuring an a-Si:H/TiO2/Al rear contact is due to severe degradation of passivation of the a-Si:H upon FGA.

  18. Theoretical study of electronic and dynamic properties of simple metal clusters in jellium model

    International Nuclear Information System (INIS)

    El-Amine Madjet, M.

    1994-01-01

    We have studied the electronic properties of alkali-metal clusters in various theoretical approximations and in the framework of the spherical jellium model. We have investigated the ground state properties of alkali clusters both in the LDA (local density approximation) and in HF (Hartree-Fock) theory. We have compared the LDA predictions of the ground state properties to predictions obtained within the HF theory. Such a comparison permitted us to check the validity of the local density functional theory in describing the ground state of a finite fermion system. For the study of collective dipolar excitations in clusters, we have considered an electromagnetic excitation. We have investigated the collective modes in the following approximations: random phase approximation (RPA), time-dependent local-density approximation (TDLDA) and the sum-rules approach. An assessment of the approximation for the continuum state within the RPA is made by comparing with TDLDA calculations for the static and dynamic electronic properties. The comparative study that we have done on the exchange-correlation effects on the electronic and optical properties have shown that the discrepancies with measured data are due mostly to the jellium approximation for the ionic background. (author). 69 refs., 30 figs., 18 tabs

  19. Head-facial hemangiomas studied with scanning electron microscopy.

    Science.gov (United States)

    Cavallotti, Carlo; Cavallotti, Chiara; Giovannetti, Filippo; Iannetti, Giorgio

    2009-11-01

    Hemangiomas of the head or face are a frequent vascular pathology, consisting in an embryonic dysplasia that involves the cranial-facial vascular network. Hemangiomas show clinical, morphological, developmental, and structural changes during their course. Morphological, structural, ultrastructural, and clinical characteristics of head-facial hemangiomas were studied in 28 patients admitted in our hospital. Nineteen of these patients underwent surgery for the removal of the hemangiomas, whereas 9 patients were not operated on. All the removed tissues were transferred in our laboratories for the morphological staining. Light microscopy, transmission electron microscopy, and scanning electron microscopy techniques were used for the observation of all microanatomical details. All patients were studied for a clinical diagnosis, and many were subjected to surgical therapy. The morphological results revealed numerous microanatomical characteristics of the hemangiomatous vessels. The observation by light microscopy shows the afferent and the efferent vessels for every microhemangioma. All the layers of the arterial wall are uneven. The lumen of the arteriole is entirely used by a blood clot. The observation by transmission electron microscopy shows that it was impossible to see the limits of the different layers (endothelium, medial layer, and adventitia) in the whole wall of the vessels. Moreover, both the muscular and elastic components are disarranged and replaced with connective tissue. The observation by scanning electron microscopy shows that the corrosion cast of the hemangioma offers 3 periods of filling: initially with partial filling of the arteriolar and of the whole cast, intermediate with the entire filling of the whole cast (including arteriole and venule), and a last period with a partial emptying of the arteriolar and whole cast while the venule remains totally injected with resin. Our morphological results can be useful to clinicians for a precise

  20. Electron emission relevant to inner-shell photoionization of condensed water studied by multi-electron coincidence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hikosaka, Y., E-mail: hikosaka@las.u-toyama.ac.jp [Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama 930-0194 (Japan); Mashiko, R.; Konosu, Y.; Soejima, K. [Department of Environmental Science, Niigata University, Niigata 950-2181 (Japan); Shigemasa, E. [UVSOR Facility, Institute for Molecular Science, Okazaki 444-8585 (Japan); SOKENDAI, Okazaki 444-8585 (Japan)

    2016-11-15

    Highlights: • Multi-electron coincidence spectroscopy is applied to the study of electron emissions from condensed H2O molecules. • Coincidence Auger spectra are obtained for different photoelectron energies. • The energy distribution of the slow electrons ejected in the Auger decay is deduced from three-fold coincidences. - Abstract: Multi-electron coincidence spectroscopy using a magnetic-bottle electron spectrometer has been applied to the study of the Auger decay following O1s photoionization of condensed H{sub 2}O molecules. Coincidence Auger spectra are obtained for three different photoelectron energy ranges. In addition, the energy distribution of the slow electrons ejected in the Auger decay of the O1s core hole is deduced from three-fold coincidences.

  1. Digital Reading Disposition Scale: A Study of Validity and Reliability

    Science.gov (United States)

    Bulut, Berker; Karasakaloglu, Nuri

    2018-01-01

    In this study, "a Digital Reading Disposition Scale" was developed to determine undergraduate pre-service teacher students' dispositions towards digital reading, opposed to a preference for printed reading material. Initially, a 20-items trial version of the scale was administered to a total sample of N = 301 undergraduate pre-service…

  2. A Validity Study: Attitudes towards Statistics among Japanese College Students

    Science.gov (United States)

    Satake, Eike

    2015-01-01

    This cross-cultural study investigated the relationship between attitudes toward statistics (ATS) and course achievement (CA) among Japanese college students. The sample consisted of 135 male and 134 female students from the first two-year liberal arts program of a four-year college in Tokyo, Japan. Attitudes about statistics were measured using…

  3. Validity of the Rosenfeld relationship: A comparative study of the ...

    Indian Academy of Sciences (India)

    ATREYEE BANERJEE

    we find that the NTW model has mixed characteristics of simple liquids and ionic melts. Our study further ... and the value of the Rosenfeld exponents are differ- ent from that found for ..... Lennard-Jones chains J. Chem. Phys. 129 164904. 4.

  4. Evaluating the Reliability, Validity, and Usefulness of Education Cost Studies

    Science.gov (United States)

    Baker, Bruce D.

    2006-01-01

    Recent studies that purport to estimate the costs of constitutionally adequate education have been described as either a "gold standard" that should guide legislative school finance policy design and judicial evaluation, or as pure "alchemy." Methods for estimating the cost of constitutionally adequate education can be roughly…

  5. Perceived Coach Attitudes and Behaviors Scale: Development and Validation Study

    Science.gov (United States)

    Üzüm, Hanifi; Karli, Ünal; Yildiz, Nuh Osman

    2018-01-01

    The purpose of the study was to develop a scale, which will serve to determine how attitudes and behaviors of the coaches are perceived by the athletes. The scale, named as "Perceived Coach Attitudes and Behaviors Scale" (PCABS) was developed through various processes including exploratory and confirmatory factor analysis. Following the…

  6. Unmasking the Capability of Strategic Learning: A Validation Study

    Science.gov (United States)

    Siren, Charlotta A.

    2012-01-01

    Purpose: The strategic learning perspective has attracted increased interest among strategic management scholars, yet the operationalisation of this concept is still in its infancy. The aim of this study is to develop a multidimensional understanding of the strategic learning process and to build an instrument to measure this concept.…

  7. Concept study and validation of Antartic telescope tower

    NARCIS (Netherlands)

    Lanford, E.; Swain, M.; Meyers, C.; Muramatsu, T.; Nielson, G.; Olson, V.; Ronsse, S.; Vinding Nyden, E.; Hammerschlag, R.H.; Little, P.

    2006-01-01

    Studies by Mark Swain and a colleague at the Max Planck Institut für Astronomie, coupled with results from past and ongoing projects at Harvey Mudd College, strongly suggest that it may be possible to achieve imaging performance comparable to the Hubble Space Telescope at relatively low cost using

  8. Secondary electron emission studied by secondary electron energy loss coincidence spectroscopy (SE2ELCS)

    International Nuclear Information System (INIS)

    Khalid, R.

    2013-01-01

    Emission of secondary electrons is of importance in many branches of fundamental and applied science. It is widely applied in the electron microscope for the investigation of the structure and electronic state of solid surfaces and particle detection in electron multiplier devices, and generally it is related to the energy dissipation of energetic particles moving inside a solid. The process of secondary electron emission is a complex physical phenomenon, difficult to measure experimentally and treat theoretically with satisfactory accuracy. The secondary electron spectrum measured with single electron spectroscopy does not provide detailed information of the energy loss processes responsible for the emission of secondary electrons. This information can be accessed when two correlated electron pairs are measured in coincidence and the pair consists of a backscattered electron after a given energy loss and a resulting emitted secondary electron. To investigate the mechanisms responsible for the emission of secondary electrons, a reflection (e,2e) coincidence spectrometer named Secondary Electron Electron Energy Loss Coincidence Spectrometer (SE2ELCS) has been developed in the framework of this thesis which allows one to uncover the relation between the features in the spectra which are due to energy losses and true secondary electron emission structures. The correlated electron pairs are measured with a hemispherical mirror analyzer (HMA) and a time of flight analyzer (TOF) by employing a continuous electron beam. An effort has been made to increase the coincidence count rate by increasing the effective solid angle of the TOF analyzer and optimizing the experimental parameters to get optimum energy resolution. Double differential coincidence spectra for a number of materials namely, nearly free electron metals (Al, Si), noble metals (Ag, Au, Cu, W) and highly oriented pyrolytic graphite (HOPG) have been measured using this coincidence spectrometer. The

  9. Development and validation of outcome prediction models for aneurysmal subarachnoid haemorrhage : The SAHIT multinational cohort study

    NARCIS (Netherlands)

    Jaja, Blessing N R; Saposnik, Gustavo; Lingsma, Hester F.; Macdonald, Erin; Thorpe, Kevin E.; Mamdani, Muhammed; Steyerberg, Ewout W.; Molyneux, Andrew; Manoel, Airton Leonardo De Oliveira; Schatlo, Bawarjan; Hanggi, Daniel; Hasan, David M.; Wong, George K C; Etminan, Nima; Fukuda, Hitoshi; Torner, James C.; Schaller, Karl L.; Suarez, Jose I.; Stienen, Martin N.; Vergouwen, Mervyn D.I.; Rinkel, Gabriel J.E.; Spears, Julian; Cusimano, Michael D.; Todd, Michael; Le Roux, Peter; Kirkpatrick, Peter J.; Pickard, John; Van Den Bergh, Walter M.; Murray, Gordon D; Johnston, S. Claiborne; Yamagata, Sen; Mayer, Stephan A.; Schweizer, Tom A.; Macdonald, R. Loch

    2018-01-01

    Objective To develop and validate a set of practical prediction tools that reliably estimate the outcome of subarachnoid haemorrhage from ruptured intracranial aneurysms (SAH). Design Cohort study with logistic regression analysis to combine predictors and treatment modality. Setting Subarachnoid

  10. Attitude Patterns and the Production of Original Verbal Images: A Study in Construct Validity

    Science.gov (United States)

    Khatena, Joe; Torrance, E. Paul

    1971-01-01

    The Runner Studies of Attitude Patterns, a personality inventory, was used as the criterion to determine construct validity of Sounds and Images and Onomatopoeia and Images, two tests of verbal originality. (KW)

  11. Determination of maduramicin in feedingstuffs and premixtures by liquid chromatography : development, validation and interlaboratory study

    NARCIS (Netherlands)

    Jong, de J.; Stoisser, B.; Wagner, K.; Tomassen, M.J.H.; Driessen, J.J.M.; Hofman, P.; Putzka, H.A.

    2004-01-01

    A reversed-phase liquid chromatography method for determination of maduramicin in feedingstuffs and premixtures was developed, validated, and interlaboratory studied. The extraction solvent was methanol. Maduramicin was detected at 520 nm after postcolumn derivatization with vanillin. Recovery was

  12. Turkish Version of Kolcaba's Immobilization Comfort Questionnaire: A Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Betül Tosun, RN, PhD

    2015-12-01

    Conclusions: The findings of this study reveal that the ICQ is a valid and reliable tool for assessing the comfort of patients in Turkey who are immobilized because of lower extremity orthopedic problems.

  13. A study on the secondary electrons in a clinical electron beam

    International Nuclear Information System (INIS)

    Krithivas, G.; Rao, S.N.

    1989-01-01

    The central axis dose of a 12 MeV clinical electron beam is investigated in terms of an axial component due to primary electrons in the central ray and a lateral component due to secondary electrons originating from multiple scattering of electrons in the off-axis rays. To this effect secondary electron fluence measurements in a polystyrene medium irradiated with a collimated beam are made with a sensitive diode detector. This leads to a construction of secondary electron depth-dose profiles for beam sizes of diameters ranging from 1.7 to 17.4 cm. The results indicate that the lateral electrons account for 25% of the dose in the therapeutic region. For these electrons, the depth of dose maximum is correlated with diffusion depth and maximum lateral excursion in the medium. Dose component due to backscatter electrons at depths is also investigated using a thin-window parallel-plate ion chamber. The role of lateral and backscatter electrons in characterising central axis per cent depth-dose is discussed. (author)

  14. Study of porous silicon morphologies for electron transport

    International Nuclear Information System (INIS)

    Pang, Y.; Demroff, H.P.; Elliott, T.S.; Lee, B.; Lu, J.; Madduri, V.B.; Mazumdar, T.K.; McIntyre, P.M.; Smith, D.D.; Trost, H.J.

    1993-01-01

    Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous silicon is still a single crystal. In addition, a Scanning Tunnelling Microscope (STM) and an Atomic Force Microscope (AFM) were successfully applied to image the 40 angstrom gold film structure which was coated upon a cooled porous silicon layer. By associating the morphology study with the measured emitting current density of the Oxidized Porous Silicon Field Emission Triode (OPSFET), techniques for the surface treatment of porous silicon will be optimized

  15. Resiliency Scale (RS): Scale Development, Reliability and Validity Study

    OpenAIRE

    GÜRGAN, Uğur

    2003-01-01

    The purpose of this study was to develop a new Resiliency Scale (RS) for Turkish samples. Various items from some major resiliency scales, most of them with some partial change, were collected and a pool of 228 items containing almost all possible resilience areas were obtained. This item-pool was administered to a college sample of 419. Resulting of analysis 50 item RS were obtained and administered to a new college sample of 112 participants. This second sample has also received the Rosenba...

  16. Validation of protein carbonyl measurement: A multi-centre study

    Directory of Open Access Journals (Sweden)

    Edyta Augustyniak

    2015-04-01

    Full Text Available Protein carbonyls are widely analysed as a measure of protein oxidation. Several different methods exist for their determination. A previous study had described orders of magnitude variance that existed when protein carbonyls were analysed in a single laboratory by ELISA using different commercial kits. We have further explored the potential causes of variance in carbonyl analysis in a ring study. A soluble protein fraction was prepared from rat liver and exposed to 0, 5 and 15 min of UV irradiation. Lyophilised preparations were distributed to six different laboratories that routinely undertook protein carbonyl analysis across Europe. ELISA and Western blotting techniques detected an increase in protein carbonyl formation between 0 and 5 min of UV irradiation irrespective of method used. After irradiation for 15 min, less oxidation was detected by half of the laboratories than after 5 min irradiation. Three of the four ELISA carbonyl results fell within 95% confidence intervals. Likely errors in calculating absolute carbonyl values may be attributed to differences in standardisation. Out of up to 88 proteins identified as containing carbonyl groups after tryptic cleavage of irradiated and control liver proteins, only seven were common in all three liver preparations. Lysine and arginine residues modified by carbonyls are likely to be resistant to tryptic proteolysis. Use of a cocktail of proteases may increase the recovery of oxidised peptides. In conclusion, standardisation is critical for carbonyl analysis and heavily oxidised proteins may not be effectively analysed by any existing technique.

  17. MUNU: study of the neutrino-electron scattering; MUNU: etude de la diffusion neutrino-electron

    Energy Technology Data Exchange (ETDEWEB)

    Cerna, C

    2000-11-01

    MUNU is an experiment dedicated to electron-neutrino scattering studies and in particular to neutrino magnetic moment search at a nuclear power plant in Bugey (France). MUNU is based on a gaseous time projection chamber (TPC) immersed in 8 tons of liquid scintillator acting as an active anti-Compton shielding. A preliminary analysis of the first results of this experiment corresponding to about 24 days of data collecting draws a line on the value of the neutrino magnetic moment: {mu}{sub {nu}}-bar{sub {sub e}} {<=} 1.97 10{sup -10} {mu}{sub B} (68% confidence level). All along this work, it is shown that the combined use of a TPC and of a light detection system is valuable for discriminating particles and for discarding signals from background noise.

  18. Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron–electron interactions, application to graphene

    International Nuclear Information System (INIS)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-01-01

    Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron–electron (e–e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e–e interactions. This required adapting the treatment of e–e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

  19. Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron–electron interactions, application to graphene

    Energy Technology Data Exchange (ETDEWEB)

    Borowik, Piotr, E-mail: pborow@poczta.onet.pl [Warsaw University of Technology, Faculty of Physics, ul. Koszykowa 75, 00-662 Warszawa (Poland); Thobel, Jean-Luc, E-mail: jean-luc.thobel@iemn.univ-lille1.fr [Institut d' Electronique, de Microélectronique et de Nanotechnologies, UMR CNRS 8520, Université Lille 1, Avenue Poincaré, CS 60069, 59652 Villeneuve d' Ascq Cédex (France); Adamowicz, Leszek, E-mail: adamo@if.pw.edu.pl [Warsaw University of Technology, Faculty of Physics, ul. Koszykowa 75, 00-662 Warszawa (Poland)

    2017-07-15

    Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron–electron (e–e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e–e interactions. This required adapting the treatment of e–e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

  20. Validity of self reported male balding patterns in epidemiological studies

    Directory of Open Access Journals (Sweden)

    Leavy Justine E

    2004-12-01

    Full Text Available Abstract Background Several studies have investigated the association between male pattern baldness and disease such as prostate cancer and cardiovascular disease. Limitations in the lack of standardized instruments to measure male pattern baldness have resulted in researchers measuring balding patterns in a variety of ways. This paper examines the accuracy and reliability of assessment of balding patterns by both trained observers and men themselves, using the Hamilton-Norwood classification system. Methods An observational study was carried out in Western Australia with 105 male volunteers aged between 30 and 70 years. Participants completed a short questionnaire and selected a picture that best represented their balding pattern. Two trained data collectors also independently assessed the participant's balding pattern using the same system and the men's self assessment was compared with the trained observer's assessment. In a substudy, observers assessed the balding pattern in a photo of the man aged 35 years while the man independently rated his balding at that age. Results Observers were very reliable in their assessment of balding pattern (85% exact agreement, κ = 0.83. Compared to trained observers, men were moderately accurate in their self-assessment of their balding status (48–55% exact agreement, κ = 0.39–0.46. For the substudy the exact agreement between the men and the observers was 67% and the agreement within balding groups was 87%. Conclusions We recommend that male balding patterns be assessed by trained personnel using the Hamilton-Norwood classification system. Where the use of trained personnel is not feasible, men's self assessment both currently and retrospectively has been shown to be adequate.

  1. A study on the validity of strategic classification processes

    International Nuclear Information System (INIS)

    Tae, Jae Woong; Shin, Dong Hun

    2013-01-01

    The commodity classification is to identify strategic commodity. The export license is to verify that exports have met the conditions required by the international export control system. NSSC (Nuclear Safety and Security Commission) operates the NEPS (Nuclear Export Promotion Service) for export control of nuclear items. NEPS contributed to reduce process time related to submission of documents, issuing certificates and licenses, etc. Nonetheless, it became necessary to enhance capacity to implement export control precisely and efficiently as development of Korean nuclear industry led to sharp increase of export. To provide more efficient ways, development of the advanced export control system, IXCS (Intelligent eXport Control System) was suggested. To build IXCS successfully, export control experts have analyzed Korean export control system. Two classification processes of items and technology were derived as a result of the research. However, it may reflect real cases insufficiently because it is derived by experts' discussion. This study evaluated how well the process explains real cases. Although the derived processes explained real cases well, some recommendations for improvement were found through this study. These evaluation results will help to make classification flow charts more compatible to the current export system. Most classification reports on equipment and material deliberated specification and functions while related systems were not considered. If a 'specification review' stage is added to the current process and delete unnecessary stages, this will improve accuracy of the flow chart. In the classification of nuclear technology, detailed process to identify specific information and data need to be specified to decrease subjectivity. Whether they are imitations or not is an unnecessary factor in both processes. The successful development of IXCS needs accurate export control processes as well as IT technology. If these classification processes are

  2. Development of a quality-assessment tool for experimental bruxism studies: reliability and validity.

    Science.gov (United States)

    Dawson, Andreas; Raphael, Karen G; Glaros, Alan; Axelsson, Susanna; Arima, Taro; Ernberg, Malin; Farella, Mauro; Lobbezoo, Frank; Manfredini, Daniele; Michelotti, Ambra; Svensson, Peter; List, Thomas

    2013-01-01

    To combine empirical evidence and expert opinion in a formal consensus method in order to develop a quality-assessment tool for experimental bruxism studies in systematic reviews. Tool development comprised five steps: (1) preliminary decisions, (2) item generation, (3) face-validity assessment, (4) reliability and discriminitive validity assessment, and (5) instrument refinement. The kappa value and phi-coefficient were calculated to assess inter-observer reliability and discriminative ability, respectively. Following preliminary decisions and a literature review, a list of 52 items to be considered for inclusion in the tool was compiled. Eleven experts were invited to join a Delphi panel and 10 accepted. Four Delphi rounds reduced the preliminary tool-Quality-Assessment Tool for Experimental Bruxism Studies (Qu-ATEBS)- to 8 items: study aim, study sample, control condition or group, study design, experimental bruxism task, statistics, interpretation of results, and conflict of interest statement. Consensus among the Delphi panelists yielded good face validity. Inter-observer reliability was acceptable (k = 0.77). Discriminative validity was excellent (phi coefficient 1.0; P reviews of experimental bruxism studies, exhibits face validity, excellent discriminative validity, and acceptable inter-observer reliability. Development of quality assessment tools for many other topics in the orofacial pain literature is needed and may follow the described procedure.

  3. Development of caries risk assessment tool for Iranian preschoolers: A primary validation study

    Directory of Open Access Journals (Sweden)

    Shiva Mortazavi

    2017-01-01

    Full Text Available Background: The aim of the present study was to develop a dental caries risk assessment tool for Iranian preschoolers. Methods: In a validation and cross-sectional study, a random sample of 150 preschool children was involved. This study was conducted in three phases: questionnaire design (expert panel and peer evaluation, questionnaire testing (pilot evaluation and field testing, and validation study. The initial assessments include interview, dental examination, and laboratory investigations. Validity and reliability indices, content validity index (CVI, content validity ratio (CVR, impact score, and test-retest and Cronbach's alpha were measured. Decayed, missing, filled teeth (dmft scores were calculated according to the WHO guidelines. Results: The Iranian version of caries risk assessment (CRA questionnaire contained 17 items. Cronbach's alpha coefficient (0.86 indicated a suitable internal consistency. The mean scores for the CVI and the CVR were 0.87 and 0.78, respectively. The prevalence rate of dental caries in the study group was 69.3%, and the mean dmft was 4.57 (range 0–19. Conclusions: The Persian version of CRA questionnaire was adapted to the Iranian population. The findings demonstrated overall acceptable validity and also reliability in the application of test-retest. The results of the present study provide initial evidence that the designed CRA form could be a useful tool for CRA in the Iranian preschoolers.

  4. Study on the compensation of electron beam space charge in facilittes with electron cooling

    International Nuclear Information System (INIS)

    Dikanskij, N.S.; Kudelajnen, V.I.; Parkhomchuk, V.V.; Pestrikov, D.V.

    1981-01-01

    The results of experimental investigations of a compensated electron beam on the NAP-M facility are presented. The electron beam is compensated by electrostatic plugs preventing ion leakage along the beam. Cut-off electrodes have the shape of cutted cylinders encircling the electron beam. To eliminate electron accumulation around the plugs one of the electrodes has a zero potential, which results in formation of an transverse electric field causing ionization electron drift in the transverse direction to the electric and magnetic fields. The effect of wave damping, in the compensated beam is observed, that demonstrates the possibility of gaining great current densities in long compensated beams necessary for antiproton storage. For the NAP-M at the 10 10 cm/s electron velocity, 300 cm length of ion column, and 1 kOe field intensity the threshold beam current density is 0.96 A/cm 2 [ru

  5. An environment-dependent semi-empirical tight binding model suitable for electron transport in bulk metals, metal alloys, metallic interfaces, and metallic nanostructures. I. Model and validation

    Energy Technology Data Exchange (ETDEWEB)

    Hegde, Ganesh, E-mail: ghegde@purdue.edu; Povolotskyi, Michael; Kubis, Tillmann; Klimeck, Gerhard, E-mail: gekco@purdue.edu [Network for Computational Nanotechnology (NCN), Department of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Boykin, Timothy [Department of Electrical and Computer Engineering, University of Alabama, Huntsville, Alabama (United States)

    2014-03-28

    Semi-empirical Tight Binding (TB) is known to be a scalable and accurate atomistic representation for electron transport for realistically extended nano-scaled semiconductor devices that might contain millions of atoms. In this paper, an environment-aware and transferable TB model suitable for electronic structure and transport simulations in technologically relevant metals, metallic alloys, metal nanostructures, and metallic interface systems are described. Part I of this paper describes the development and validation of the new TB model. The new model incorporates intra-atomic diagonal and off-diagonal elements for implicit self-consistency and greater transferability across bonding environments. The dependence of the on-site energies on strain has been obtained by appealing to the Moments Theorem that links closed electron paths in the system to energy moments of angular momentum resolved local density of states obtained ab initio. The model matches self-consistent density functional theory electronic structure results for bulk face centered cubic metals with and without strain, metallic alloys, metallic interfaces, and metallic nanostructures with high accuracy and can be used in predictive electronic structure and transport problems in metallic systems at realistically extended length scales.

  6. An environment-dependent semi-empirical tight binding model suitable for electron transport in bulk metals, metal alloys, metallic interfaces, and metallic nanostructures. I. Model and validation

    International Nuclear Information System (INIS)

    Hegde, Ganesh; Povolotskyi, Michael; Kubis, Tillmann; Klimeck, Gerhard; Boykin, Timothy

    2014-01-01

    Semi-empirical Tight Binding (TB) is known to be a scalable and accurate atomistic representation for electron transport for realistically extended nano-scaled semiconductor devices that might contain millions of atoms. In this paper, an environment-aware and transferable TB model suitable for electronic structure and transport simulations in technologically relevant metals, metallic alloys, metal nanostructures, and metallic interface systems are described. Part I of this paper describes the development and validation of the new TB model. The new model incorporates intra-atomic diagonal and off-diagonal elements for implicit self-consistency and greater transferability across bonding environments. The dependence of the on-site energies on strain has been obtained by appealing to the Moments Theorem that links closed electron paths in the system to energy moments of angular momentum resolved local density of states obtained ab initio. The model matches self-consistent density functional theory electronic structure results for bulk face centered cubic metals with and without strain, metallic alloys, metallic interfaces, and metallic nanostructures with high accuracy and can be used in predictive electronic structure and transport problems in metallic systems at realistically extended length scales

  7. An environment-dependent semi-empirical tight binding model suitable for electron transport in bulk metals, metal alloys, metallic interfaces, and metallic nanostructures. I. Model and validation

    Science.gov (United States)

    Hegde, Ganesh; Povolotskyi, Michael; Kubis, Tillmann; Boykin, Timothy; Klimeck, Gerhard

    2014-03-01

    Semi-empirical Tight Binding (TB) is known to be a scalable and accurate atomistic representation for electron transport for realistically extended nano-scaled semiconductor devices that might contain millions of atoms. In this paper, an environment-aware and transferable TB model suitable for electronic structure and transport simulations in technologically relevant metals, metallic alloys, metal nanostructures, and metallic interface systems are described. Part I of this paper describes the development and validation of the new TB model. The new model incorporates intra-atomic diagonal and off-diagonal elements for implicit self-consistency and greater transferability across bonding environments. The dependence of the on-site energies on strain has been obtained by appealing to the Moments Theorem that links closed electron paths in the system to energy moments of angular momentum resolved local density of states obtained ab initio. The model matches self-consistent density functional theory electronic structure results for bulk face centered cubic metals with and without strain, metallic alloys, metallic interfaces, and metallic nanostructures with high accuracy and can be used in predictive electronic structure and transport problems in metallic systems at realistically extended length scales.

  8. Study of experimental validation for combustion analysis of GOTHIC code

    International Nuclear Information System (INIS)

    Lee, J. Y.; Yang, S. Y.; Park, K. C.; Jeong, S. H.

    2001-01-01

    In this study, present lumped and subdivided GOTHIC6 code analyses of the premixed hydrogen combustion experiment at the Seoul National University and comparison with the experiment results. The experimental facility has 16367 cc free volume and rectangular shape. And the test was performed with unit equivalence ratio of the hydrogen and air, and with various location of igniter position. Using the lumped and mechanistic combustion model in GOTHIC6 code, the experiments were simulated with the same conditions. In the comparison between experiment and calculated results, the GOTHIC6 prediction of the combustion response does not compare well with the experiment results. In the point of combustion time, the lumped combustion model of GOTHIC6 code does not simulate the physical phenomena of combustion appropriately. In the case of mechanistic combustion model, the combustion time is predicted well, but the induction time of calculation data is longer than the experiment data remarkably. Also, the laminar combustion model of GOTHIC6 has deficiency to simulate combustion phenomena unless control the user defined value appropriately. And the pressure is not a proper variable that characterize the three dimensional effect of combustion

  9. Human immunotoxicologic markers of chemical exposures: preliminary validation studies.

    Science.gov (United States)

    Wartenberg, D; Laskin, D; Kipen, H

    1993-01-01

    The circulating cells of the immune system are sensitive to environmental contaminants, and effects are often manifested as changes in the cell surface differentiation antigens of affected populations of cells, particularly lymphocytes. In this investigation, we explore the likelihood that variation in the expression of the surface markers of immune cells can be used as an index of exposure to toxic chemicals. We recruited 38 healthy New Jersey men to study pesticides effects: 19 orchard farmers (high exposure); 13 berry farmers (low exposure); and 6 hardware store owners (no exposure). Immunophenotyping was performed assaying the following cell surface antigens: CD2, CD4, CD8, CD14, CD20, CD26, CD29, CD45R, CD56, and PMN. Data were analyzed using univariate and multivariate methods. There were no significant differences among the groups with respect to routine medical histories, physical examinations, or routine laboratory parameters. No striking differences between groups were seen in univariate tests. Multivariate tests suggested some differences among groups and limited ability to correctly classify individuals based on immunophenotyping results. Immunophenotyping represents a fruitful area of research for improved exposure classification. Work is needed both on mechanistic understanding of the patterns observed and on the statistical interpretation of these patterns.

  10. Study of the mass of the electron neutrino in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Yasumi, Shinjiro; Maezawa, Hideki [eds.

    1996-02-01

    This report describes a study of the mass of the electron neutrino using electron capture in {sup 163}Ho in Japan for the period from 1981 to 1994. This monograph has two purposes, one is to supplement the papers on the mass of the electron neutrino already published by us and another is to make a record on some details of our experiments for future. Electron capture in a nucleus takes place in a rather small space inside an atom, where atomic physics, nuclear physics and particle physics work closely together. Therefore, this study needed an intimate collaboration of atomic physicists, nuclear physicists and particle physicists. In addition, it was necessary for this study to use various fine techniques, including metallurgy, production of {sup 163}Ho activity, micro-analysis by wet chemistry, isotope-dilution mass spectrometry, undulator radiation source technology, the soft X-ray monochromator technology, a counting technique for very intense soft X-rays and so on. As a result, our collaboration consisted of many researchers from various fields as follows; M. Ando, H. Arai, M. Fujioka, N. Hashimoto, H. Ikeda, Y. Inagaki, K. Ishii, K. Itoh, G. Izawa, O. Kawakami, S. Kishimoto, H. Kitamura, H. Maezawa, M. Maruyama, A. Masuda, K. Masumoto, A. Mikuni, T. Mizogawa, T. Mukoyama, F. Ochiai, T. Ohta, T. Omori, G. Rajasekaran, K. Sera, K. Shima, T. Shinozuka, P.M. Stefan, I. Sugai, H. Taketani, M. Yagi, and S. Yasumi. Without such an excellent collaboration, this study would not have been completed. We would like to express our sincere gratitude to Professor T. Sasaki for supporting this study and recommending the undulator beam line of 2.5 GeV Photon Factory Storage Ring as a light source to be used in the experiment. We also would like to thank Dr. A. Yagishita and Dr. Y. Kitajima who are responsible for the BL-2 beamline. Finally we are grateful to Ms. M. Noji for her patient typewriting of manuscripts written by hand. (author).

  11. Color formation study of irradiated polymers by electron beam

    International Nuclear Information System (INIS)

    Nardi, Daniela Teves

    2004-01-01

    Color formation on national and commercial polymers (polymethyl methacrylate, polystyrene and polycarbonate) irradiated by electrons beam was investigated by colorimetry (CIELab), electron spectroscopy resonance (ESR), photoacoustic infrared spectroscopy (FTIR-PAS) and differential exploratory calorimetry (DSC). The heat effect on colorimetric properties was investigated after heating (110 deg C for 1 hour) of irradiated polymers at 150 kGy. The rule of oxygen in colorimetric properties of irradiated polycarbonate was investigated in the air presence and absence (p = 10 -3 mmHg). The visual aspect did not agree with colorimetric parameters only for polycarbonate. Yellow color and darkness were induced by radiation for all studied polymers varying only the intensity and behavior in function of post-irradiation time and heating. Polymethyl methacrylate and polystyrene ESR spectra showed that radicals could be responsible by yellow color centers. Wherever, in polycarbonate, color centers were not due radical species. The nature of color centers for any studied polymer was not study by FTIR-PAS because there were no changes in FTIR-PAS spectra neither in function of dose nor heating. Polycarbonate was the most radiosensible and polystyrene was the most radioresistant of all studied polymers in concern of colorimetric properties. (author)

  12. Postponed variety creation: case study in consumer electronics retail

    DEFF Research Database (Denmark)

    Appelqvist, Patrik; Gubi, Ebbe

    2004-01-01

    Purpose – Postponement is known as a way to reduce risk and inventories while still providing high product variety and acceptable response times. The paper is a case study that uses simulation for quantifying these benefits for a consumer electronics company. Design/methodology/approach – Improve......Purpose – Postponement is known as a way to reduce risk and inventories while still providing high product variety and acceptable response times. The paper is a case study that uses simulation for quantifying these benefits for a consumer electronics company. Design...... is beneficial in retail. Findings – In the case company, shop inventory is necessary for high-volume and low-variety products. Postponing variety creation to shops has the potential to decrease inventories for these products by 40-80 per cent. The benefits of postponement depend on delivery speed requirement......, product value, product variety and shop size. Research limitations/implications – Many contributions on postponement have been conceptual. This study contains a quantitative test. The study considers both the spatial dimension (where) and the temporal dimension (when) of postponement. Practical...

  13. Postponed variety creation: case study in consumer electronics retail

    DEFF Research Database (Denmark)

    Appelqvist, Patrik; Gubi, Ebbe

    2005-01-01

    Purpose – Postponement is known as a way to reduce risk and inventories while still providing high product variety and acceptable response times. The paper is a case study that uses simulation for quantifying these benefits for a consumer electronics company. Design/methodology/approach – Improve......Purpose – Postponement is known as a way to reduce risk and inventories while still providing high product variety and acceptable response times. The paper is a case study that uses simulation for quantifying these benefits for a consumer electronics company. Design...... is beneficial in retail. Findings – In the case company, shop inventory is necessary for high-volume and low-variety products. Postponing variety creation to shops has the potential to decrease inventories for these products by 40-80 per cent. The benefits of postponement depend on delivery speed requirement......, product value, product variety and shop size. Research limitations/implications – Many contributions on postponement have been conceptual. This study contains a quantitative test. The study considers both the spatial dimension (where) and the temporal dimension (when) of postponement. Practical...

  14. A comparative study of electronic stethoscopes for cardiac auscultation.

    Science.gov (United States)

    Pinto, C; Pereira, D; Ferreira-Coimbra, J; Portugues, J; Gama, V; Coimbra, M

    2017-07-01

    There are several electronic stethoscopes available on the market today, with a very high potential for healthcare namely telemedicine, assisted decision and education. However, there are no recent comparatives studies published about the recording quality of auscultation sounds. In this study we aim to: a) define a ranking, according to experts opinion of 6 of the most relevant electronic stethoscopes on the market today; b) verify if there are any relations between a stethoscope's performance and the type of pathology present; c) analyze if some pathologies are more easily identified than others when using electronic auscultation. Our methodology consisted in creating two study groups: the first group included 18 cardiologists and cardiology house officers, acting as the gold standard of this work. The second included 30 medical students. Using a database of heart sounds recorded in real hospital environments, we applied questionnaires to observers from each group. The first group listened to 60 cardiac auscultations recorded by the 6 stethoscopes, and each one was asked to identify the pathological sound present: aortic stenosis, mitral regurgitation or normal. The second group was asked to choose, between two auscultation recordings, using as criteria the best sound quality for the identification of pathological sounds. Results include a total of 1080 evaluations, in which 72% of cases were correctly diagnosed. A detailed breakdown of these results is presented in this paper. As conclusions, results showed that the impact of the differences between stethoscopes is very small, given that we did not find statistically significant differences between all pairs of stethoscopes. Normal sounds showed to be easier to identify than pathological sounds, but we did not find differences between stethoscopes in this identification.

  15. International validation study for interim PET in ABVD-treated, advanced-stage hodgkin lymphoma

    DEFF Research Database (Denmark)

    Biggi, Alberto; Gallamini, Andrea; Chauvie, Stephane

    2013-01-01

    At present, there are no standard criteria that have been validated for interim PET reporting in lymphoma. In 2009, an international workshop attended by hematologists and nuclear medicine experts in Deauville, France, proposed to develop simple and reproducible rules for interim PET reporting...... in lymphoma. Accordingly, an international validation study was undertaken with the primary aim of validating the prognostic role of interim PET using the Deauville 5-point score to evaluate images and with the secondary aim of measuring concordance rates among reviewers using the same 5-point score...

  16. Uranyl soaps - thermal, electronic and infrared spectral study

    International Nuclear Information System (INIS)

    Solanki, A.K.; Bhandari, A.M.

    1981-01-01

    The electronic and infrared spectra and TGA thermogram of uranyl soaps (laurate, mystrate, palmitate and stearate) have been studied. The environment about the UO 2+ 2 ion would comprise two 'short bite' bidentate carboxylate groups and oxygen atoms bridging from adjacent carboxylic molecules. The uranyl soaps have UO 2+ 2 vibronic absorption (approx. equal to 22730 cm -1 ) in the range found for eight coordinate uranyl complexes. The greater resistance to thermal degradation (approx. equal to 300 0 C) of these soaps and their stepwise thermal degradation infer strong metal-ligand interaction. (orig.) [de

  17. Transmission electron microscopic study of reduced Ca2UO5

    International Nuclear Information System (INIS)

    Krasevec, V.; Prodan, A.; Holc, J.; Kolar, D.

    1983-01-01

    Structural changes of Ca 2 UO 5 during reduction in hydrogen were studied by transmission electron microscopy. It was shown that monoclinic Ca 2 UO 5 changes into triclinic Ca 4 U 2 O 9 . They are related, respectively, to the fluorite and the bixbyite (C-M 2 O 3 ) structures, so that the product is a superstructure of the latter. Reduction occurs along the (100)/sub t/ planes originating from the (006)/sub m/ planes of the parent structure by diminishing the coordination number of the Ca cation from 7 to 6. 5 figures

  18. Development and validation of an automated delirium risk assessment system (Auto-DelRAS) implemented in the electronic health record system.

    Science.gov (United States)

    Moon, Kyoung-Ja; Jin, Yinji; Jin, Taixian; Lee, Sun-Mi

    2018-01-01

    A key component of the delirium management is prevention and early detection. To develop an automated delirium risk assessment system (Auto-DelRAS) that automatically alerts health care providers of an intensive care unit (ICU) patient's delirium risk based only on data collected in an electronic health record (EHR) system, and to evaluate the clinical validity of this system. Cohort and system development designs were used. Medical and surgical ICUs in two university hospitals in Seoul, Korea. A total of 3284 patients for the development of Auto-DelRAS, 325 for external validation, 694 for validation after clinical applications. The 4211 data items were extracted from the EHR system and delirium was measured using CAM-ICU (Confusion Assessment Method for Intensive Care Unit). The potential predictors were selected and a logistic regression model was established to create a delirium risk scoring algorithm to construct the Auto-DelRAS. The Auto-DelRAS was evaluated at three months and one year after its application to clinical practice to establish the predictive validity of the system. Eleven predictors were finally included in the logistic regression model. The results of the Auto-DelRAS risk assessment were shown as high/moderate/low risk on a Kardex screen. The predictive validity, analyzed after the clinical application of Auto-DelRAS after one year, showed a sensitivity of 0.88, specificity of 0.72, positive predictive value of 0.53, negative predictive value of 0.94, and a Youden index of 0.59. A relatively high level of predictive validity was maintained with the Auto-DelRAS system, even one year after it was applied to clinical practice. Copyright © 2017. Published by Elsevier Ltd.

  19. The Validity of Graduate Management Admission Test Scores: A Summary of Studies Conducted from 1997 to 2004

    Science.gov (United States)

    Talento-Miller, Eileen; Rudner, Lawrence M.

    2008-01-01

    The validity of Graduate Management Admission Test (GMAT) scores is examined by summarizing 273 studies conducted between 1997 and 2004. Each of the studies was conducted through the Validity Study Service of the test sponsor and contained identical variables and statistical methods. Validity coefficients from each of the studies were corrected…

  20. Studies of the longitudinal instability with an electron beam

    International Nuclear Information System (INIS)

    1993-01-01

    Goals for our first-year period are as follows: To study the evolution of a small perturbation in the current pulse (introduced via the grid voltage on the electron gun) when the beam propagates through our 5-m long periodic solenoid channel. Specifically, to see if the perturbation is reflected from the rear end of the pulse. So far these objectives have been met without any delays. We were able to launch different perturbations on the beam resulting in either a slow space-charge wave or a fast wave or both waves. The relative strength of each wave was found to depend on the electron emission temperature of the cathode. The propagation of these waves on an initially rectangular longitudinal beam profile was measured with fast current monitors and the kinetic energy was measured with sensitive energy analyzers at various positions along the 5-m long solenoidal focusing channel. We have also begun to study the behavior of the waves when they reach the respective edge of the beam. But this work is still of a preliminary nature, and we need to refine the beam conditions and measurements in future studies to reach any firm conclusions. Preparations for the resistive-wall instability experiment are in progress

  1. Studies of electron correlation in the photoionization process

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Richard Allen [Univ. of California, Berkeley, CA (United States)

    1979-03-01

    Electron correlation is a result of the interaction of two or more electrons confined in a region of space, and may conveniently be treated under the formalism of configuration interaction (CI). Photoionization provides a rather direct experimental method for studying configuration interaction. The types of CI involved in the photoionization process can be divided into three categories: initial state configuration interaction (ISCI), final ionic state configuration interaction (FISCI), and continuum state configuration interaction (CSCI). This thesis deals with experimental studies which reveal how the various types of CI may become manifested in photoionization. The experimental methods utilized in this work are photoelectron spectroscopy (PES), electron impact spectroscopy (EIS), and time-resolved fluorescence spectroscopy. The EIS was carried out following the discovery that the UV lamp on a Perkin-Elmer photoelectron spectrometer could be utilized as a source of low energy electrons. The time-resolved fluorescence work utilized both the tunability and the time structure of the radiation available at the Stanford Synchrotron Radiation Laboratory (SSRL). A commercial photoelectron spectrometer equipped with a conventional UV lamp (Hei, Nei) was employed for some of the PES studies, and a novel time-of-flight photoelectron spectrometer was developed for the PES work performed using synchrotron radiation. The PES of Ba, Sm, Eu, and Yb was studied using both Hei (22.22 eV) and Nei (16.85 eV) radiation. Satellite structure observed in these spectra using Nei (and for Yb, Hei also) radiation could be satisfactorily explained by ISCI alone. The Hei spectra of Sm, Eu, and, in particular, Ba showed dramatic changes in the satellite population which could only be explained by a new mechanism, autoionization, which is a special form of CSCI. The detailed nature of this mechanism was explored in Ba using synchrotron radiation. It was found that the autoionizing level decays

  2. The present status of the study on the validity of concurrent verbalization

    International Nuclear Information System (INIS)

    Watanabe, Megumi; Takahashi, Hideaki.

    1993-09-01

    We reviewed study on the validity of the method of verbal reports. The method of verbal reports gives us detailed information about human cognitive process as compared with observing a sequence of actions, while it is subjected to criticism for the validity as data. Ericsson and Simon proposed a model of verbalization and investigated conditions to keep verbal reports valid. Although a lot of studies quote their model as a base of adopting the method of verbal reports, verification the validity of verbal reports is incomplete because effects of verbalization is not clear. We pointed out that it is necessary to take into consideration kinds of task strategies, effects of trial repetition, effects of task difficulty to examine precisely effects of verbalization. (author)

  3. The Prediction of Training Proficiency in Firefighters: A Study of Predictive Validity in Spain

    Directory of Open Access Journals (Sweden)

    Alfredo Berges

    2018-02-01

    Full Text Available The present study provides results of criterion validity in the selection of firefighters in Spain. The predictors were cognitive skills, job knowledge, and physical aptitudes, and the criterion was training proficiency. The process involves 639 candidates, but only 44 complete successfully the selection process. Our results support previous evidence showing that general cognitive ability is the best predictor of training proficiency, with an operational validity of .57. With respect to the other predictors, job knowledge presented an operational validity of .55 and physical tests of .49. In addition, multiple regression analysis showed that cognitive aptitude explains 33% of the variance, but when physical aptitudes are included the explained variance increases to 50%. If we also add job knowledge, explained variance increases to 55%. Our study offers recent results of criterion validity in a barely investigated job, gathered in a country other than the one where prior research had been carried out.

  4. Validation study of genetic biomarkers of response to TNF inhibitors in rheumatoid arthritis.

    Directory of Open Access Journals (Sweden)

    Rosario Lopez-Rodriguez

    Full Text Available Genetic biomarkers are sought to personalize treatment of patients with rheumatoid arthritis (RA, given their variable response to TNF inhibitors (TNFi. However, no genetic biomaker is yet sufficiently validated. Here, we report a validation study of 18 previously reported genetic biomarkers, including 11 from GWAS of response to TNFi. The validation was attempted in 581 patients with RA that had not been treated with biologic antirheumatic drugs previously. Their response to TNFi was evaluated at 3, 6 and 12 months in two ways: change in the DAS28 measure of disease activity, and according to the EULAR criteria for response to antirheumatic drugs. Association of these parameters with the genotypes, obtained by PCR amplification followed by single-base extension, was tested with regression analysis. These analyses were adjusted for baseline DAS28, sex, and the specific TNFi. However, none of the proposed biomarkers was validated, as none showed association with response to TNFi in our study, even at the time of assessment and with the outcome that showed the most significant result in previous studies. These negative results are notable because this was the first independent validation study for 12 of the biomarkers, and because they indicate that prudence is needed in the interpretation of the proposed biomarkers of response to TNFi even when they are supported by very low p values. The results also emphasize the requirement of independent replication for validation, and the need to search protocols that could increase reproducibility of the biomarkers of response to TNFi.

  5. Electron-electron luminosity in the Next Linear Collider -- a preliminary study

    International Nuclear Information System (INIS)

    Zimmermann, F.; Thompson, K.A.; Helm, R.H.

    1997-11-01

    In this paper, the authors discuss some operational aspects of electron-electron collisions at the Next Linear Collider (NLC) and estimate the luminosity attainable in such a machine. They also consider the use of two future technologies which could simplify the operation and improve the luminosity in an e - e - collider: polarized rf guns and plasma lenses

  6. Validity and Reliability of the Clinical Competency Evaluation Instrument for Use among Physiotherapy Students: Pilot study.

    Science.gov (United States)

    Muhamad, Zailani; Ramli, Ayiesah; Amat, Salleh

    2015-05-01

    The aim of this study was to determine the content validity, internal consistency, test-retest reliability and inter-rater reliability of the Clinical Competency Evaluation Instrument (CCEVI) in assessing the clinical performance of physiotherapy students. This study was carried out between June and September 2013 at University Kebangsaan Malaysia (UKM), Kuala Lumpur, Malaysia. A panel of 10 experts were identified to establish content validity by evaluating and rating each of the items used in the CCEVI with regards to their relevance in measuring students' clinical competency. A total of 50 UKM undergraduate physiotherapy students were assessed throughout their clinical placement to determine the construct validity of these items. The instrument's reliability was determined through a cross-sectional study involving a clinical performance assessment of 14 final-year undergraduate physiotherapy students. The content validity index of the entire CCEVI was 0.91, while the proportion of agreement on the content validity indices ranged from 0.83-1.00. The CCEVI construct validity was established with factor loading of ≥0.6, while internal consistency (Cronbach's alpha) overall was 0.97. Test-retest reliability of the CCEVI was confirmed with a Pearson's correlation range of 0.91-0.97 and an intraclass coefficient correlation range of 0.95-0.98. Inter-rater reliability of the CCEVI domains ranged from 0.59 to 0.97 on initial and subsequent assessments. This pilot study confirmed the content validity of the CCEVI. It showed high internal consistency, thereby providing evidence that the CCEVI has moderate to excellent inter-rater reliability. However, additional refinement in the wording of the CCEVI items, particularly in the domains of safety and documentation, is recommended to further improve the validity and reliability of the instrument.

  7. Assessment of bachelor's theses in a nursing degree with a rubrics system: Development and validation study.

    Science.gov (United States)

    González-Chordá, Víctor M; Mena-Tudela, Desirée; Salas-Medina, Pablo; Cervera-Gasch, Agueda; Orts-Cortés, Isabel; Maciá-Soler, Loreto

    2016-02-01

    Writing a bachelor thesis (BT) is the last step to obtain a nursing degree. In order to perform an effective assessment of a nursing BT, certain reliable and valid tools are required. To develop and validate a 3-rubric system (drafting process, dissertation, and viva) to assess final year nursing students' BT. A multi-disciplinary study of content validity and psychometric properties. The study was carried out between December 2014 and July 2015. Nursing Degree at Universitat Jaume I. Spain. Eleven experts (9 nursing professors and 2 education professors from 6 different universities) took part in the development and content validity stages. Fifty-two theses presented during the 2014-2015 academic year were included by consecutive sampling of cases in order to study the psychometric properties. First, a group of experts was created to validate the content of the assessment system based on three rubrics (drafting process, dissertation, and viva). Subsequently, a reliability and validity study of the rubrics was carried out on the 52 theses presented during the 2014-2015 academic year. The BT drafting process rubric has 8 criteria (S-CVI=0.93; α=0.837; ICC=0.614), the dissertation rubric has 7 criteria (S-CVI=0.9; α=0.893; ICC=0.74), and the viva rubric has 4 criteria (S-CVI=0.86; α=8.16; ICC=0.895). A nursing BT assessment system based on three rubrics (drafting process, dissertation, and viva) has been validated. This system may be transferred to other nursing degrees or degrees from other academic areas. It is necessary to continue with the validation process taking into account factors that may affect the results obtained. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. THE ADAPTATION TO TURKISH OF THE WRITING ATTITUDE SCALE (WAS): THE STUDY OF VALIDITY AND RELIABILITY

    OpenAIRE

    GÖÇER, Ali

    2016-01-01

    The purpose of this study is to make Turkish adaptation the Writing Attitude Scale (WAS) that In order to measure writing anxiety developed by Marcia et al (1984). For this purpose was carried out the Validation of a Writing Attitude Scale and to examine its reliability and validity. Writing Attitude Scale (WAS) was first translated into Turkish and, equivalence analysis of forms English / Turkish language of the scale were carried out by the reading of three English teachers / lecturers. The...

  9. A Derivation and Validation Study of an Early Blood Transfusion Needs Score for Severe Trauma Patients

    OpenAIRE

    Wang, Hao; Umejiego, Johnbosco; Robinson, Richard D.; Schrader, Chet D.; Leuck, JoAnna; Barra, Michael; Buca, Stefan; Shedd, Andrew; Bui, Andrew; Zenarosa, Nestor R.

    2016-01-01

    Background There is no existing adequate blood transfusion needs determination tool that Emergency Medical Services (EMS) personnel can use for prehospital blood transfusion initiation. In this study, a simple and pragmatic prehospital blood transfusion needs scoring system was derived and validated. Methods Local trauma registry data were reviewed retrospectively from 2004 through 2013. Patients were randomly assigned to derivation and validation cohorts. Multivariate logistic regression was...

  10. Can Electron-Rich Oxygen (O2-) Withdraw Electrons from Metal Centers? A DFT Study on Oxoanion-Caged Polyoxometalates.

    Science.gov (United States)

    Takazaki, Aki; Eda, Kazuo; Osakai, Toshiyuki; Nakajima, Takahito

    2017-10-12

    The answer to the question "Can electron-rich oxygen (O 2- ) withdraw electrons from metal centers?" is seemingly simple, but how the electron population on the M atom behaves when the O-M distance changes is a matter of controversy. A case study has been conducted for Keggin-type polyoxometalate (POM) complexes, and the first-principles electronic structure calculations were carried out not only for real POM species but also for "hypothetical" ones whose heteroatom was replaced with a point charge. From the results of natural population analysis, it was proven that even an electron-rich O 2- , owing to its larger electronegativity as a neutral atom, withdraws electrons when electron redistribution occurs by the change of the bond length. In the case where O 2- coexists with a cation having a large positive charge (e.g., P 5+ (O 2- ) 4 = [PO 4 ] 3- ), the gross electron population (GEP) on the M atom seemingly increases as the O atom comes closer, but this increment in GEP is not due to the role of the O atom but due to a Coulombic effect of the positive charge located on the cation. Furthermore, it was suggested that not GEP but net electron population (NEP) should be responsible for the redox properties.

  11. A method to study electron heating during ICRH

    International Nuclear Information System (INIS)

    Eriksson, L.G.; Hellsten, T.

    1989-01-01

    Collisionless absorption of ICRF waves occurs either by ion cyclotron absorption or by electron Landau (ELD) and transit damping (TTMP). Both ion cyclotron absorption, and direct electron absorption results in electron heating. Electron heating by minority ions occurs after a high energy tail of the resonating ions has been formed i.e. typically after 0.2-1s in present JET experiments. Electron heating through ELD, and TTMP, takes place on the timescale given by electron-electron collisions which is typically of the order of ms. This difference in the timescales can be used to separate the two damping mechanisms. This can be done by measuring the time derivatives of the electron temperature after sawtooth crashes during ramp-up and ramp-down of the RF-power. (author) 4 refs., 4 figs

  12. Studies of electron correlation in the photoionization process

    International Nuclear Information System (INIS)

    Rosenberg, R.A.

    1979-03-01

    Electron correlation is a result of the interaction of two or more electrons confined in a region of space, and may conveniently be treated under the formalism of configuration interaction (CI). Photoionization provides a rather direct experimental method for studying CI. The types of CI involved in the photoionization process can be divided into three categories: initial-state configuration interaction (ISCI), final-ionic-state configuration interaction (FISCI), and continuum-state configuration interaction (CSCI). The photoelecton spectroscopy of Ba, Sm, Eu, and Yb was studied using both HeI (22.22 eV) and NeI (16.85 eV) radiation. Satellite structure observed in these spectra using NeI (and for Yb, HeI also) radiation could be satisfactorily explained by ISCI alone. The HeI spectra of Sm, Eu, and, in particular, Ba showed dramatic changes in the satellite population which could only be explained by autoionization, a special form of CSCI. The detailed nature of this mechanism was explored in Ba with synchrotron radiation. It was found that the autoionizing level decays preferentially via an Auger-type mechanism. Further insight into autoionization was gained in the electron impact/ejected electron spectra of Ba (5p 6 6s 2 ) and Yb (5p 6 4f 14 6s 2 ). Autoionizing levels excited above the first (5p) -1 threshold decayed primarily in a two-step Auger process, leading to a relatively large number of doubly charged ions. For autoionizing states below the (5p) -1 limit, decay appears to go to ground and excited states of the singly charged ion. The first experimental determination of the lifetime of the XeII 5s5p 6 2 S/sub 1/2/ state yielded a value of 34.4(6) ns. Reasonable agreement with theory could only be reached by including both FISCI and relativistic effects in calculating the lifetime. 173 references, 43 figures, 10 tables

  13. Validation of a zero-dimensional model for prediction of NOx and engine performance for electronically controlled marine two-stroke diesel engines

    DEFF Research Database (Denmark)

    Scappin, Fabio; Stefansson, Sigurður H.; Haglind, Fredrik

    2012-01-01

    The aim of this paper is to derive a methodology suitable for energy system analysis for predicting the performance and NOx emissions of marine low speed diesel engines. The paper describes a zero-dimensional model, evaluating the engine performance by means of an energy balance and a two zone...... experimental data from two MAN B&W engines; one case being data subject to engine parameter changes corresponding to simulating an electronically controlled engine; the second case providing data covering almost all model input and output parameters. The first case of validation suggests that the model can...

  14. Design studies for the electron storage ring EUTERPE

    International Nuclear Information System (INIS)

    Xi Boling.

    1995-01-01

    The 400 MeV electron storage ring EUTERPE is under construction at Eindhoven University of Technology. The ring is to be used as an experimental tool for accelerator physics studies and synchroton radiation applications. The main task of the current research work is the electron optical design of the ring. Lattice design is a basis for machine design as a whole. Design aspects regarding the basic lattice, based on single particle dynamics, include determination of the equilibrium beam size and bunch length, design of achromatic bending sections, selection of tune values, correction of chromaticity, and minimization of the natural emittance in the ring. The basic lattice designed for the EUTERPE ring has a high flexibility so that different electron optical modes can be realized easily. In low energy storage rings with a high beam current, collective effects can cause a significant change in the bunch length, the transverse emittance and the beam lifetime. In order to ensure a good optical performance for the ring, the choice of suitable parameters concerning the vacuum and RF system are essential as far as collective effects are concerned. An estimation of the collective effects in the ring is given. The injector for EUTERPE is a 75 MeV racetrack microtron which is injected from a 10 MeV linac. In order to get sufficient beam current in the ring, a special procedure of continuous injection with an adjustable locally shifted closed orbit has been presented. Details of the injection procedure and numerical simulations are given. (orig./HSI)

  15. Electrical and Electronical Waste Generation in Turkey: Bursa Case Study

    Directory of Open Access Journals (Sweden)

    Güray SALİHOĞLU

    2016-10-01

    Full Text Available Electrical and electronical equipment that gradually take more place in our daily life, spend their service life in short times and become an e-waste problem to be solved.  Because of the hazardous components they contain, e-waste can cause environmental and human health threats if they are not properly managed. If they are managed properly, they can be a valuable raw material source, since they contain valuable metals such as copper, silver, gold, palladium and recyclable components such as plastics and metals. According to a research conducted in 2014, the global e-waste amount accounts to a source worth 52 billion $; however, only 16% of this source has been properly recycled. It is important to know the potential e-waste amount and the behaviors of people in the production of e-waste to realize a proper e-waste management in our country. The amount and property of electrical and electronic equipment and e-waste generation potential per person in Bursa was investigated in this study. A questionnaire was prepared and applied to a group of people including 31 families (100 person. The questions were to investigate the behaviors in the use, replacement, and management of electrical and electronical equipment. The findings showed that usage of lamps (fluorescent and others were higher than the other equipment, and usage of mobile phones were found to be highest in terms of devices. It was also found that when the mobiles become e-waste since the owners do not want to use them, they are not just thrown away and kept at homes instead. E-waste generation potential of a person from the families investigated was estimated to be 8.14 kg/year.

  16. Design studies for the electron storage ring EUTERPE

    Energy Technology Data Exchange (ETDEWEB)

    Boling, Xi

    1995-05-18

    The 400 MeV electron storage ring EUTERPE is under construction at Eindhoven University of Technology. The ring is to be used as an experimental tool for accelerator physics studies and synchroton radiation applications. The main task of the current research work is the electron optical design of the ring. Lattice design is a basis for machine design as a whole. Design aspects regarding the basic lattice, based on single particle dynamics, include determination of the equilibrium beam size and bunch length, design of achromatic bending sections, selection of tune values, correction of chromaticity, and minimization of the natural emittance in the ring. The basic lattice designed for the EUTERPE ring has a high flexibility so that different electron optical modes can be realized easily. In low energy storage rings with a high beam current, collective effects can cause a significant change in the bunch length, the transverse emittance and the beam lifetime. In order to ensure a good optical performance for the ring, the choice of suitable parameters concerning the vacuum and RF system are essential as far as collective effects are concerned. An estimation of the collective effects in the ring is given. The injector for EUTERPE is a 75 MeV racetrack microtron which is injected from a 10 MeV linac. In order to get sufficient beam current in the ring, a special procedure of continuous injection with an adjustable locally shifted closed orbit has been presented. Details of the injection procedure and numerical simulations are given. (orig./HSI).

  17. Principal and experimental study of source of polarized electrons

    International Nuclear Information System (INIS)

    Shang Rencheng; Gao Junfang; Xiao Yuan; Pang Wenning; Deng Jingkang

    1999-01-01

    The getting of polarized electrons was briefly introduced, that is the source of polarized electrons. The measurement of polarization in future, the application of polarized electrons in atomic and molecular physics, condensed physics, biological physics, nuclear and particle physics were discussed

  18. Study and realization of an electron gun at low energy

    International Nuclear Information System (INIS)

    Camus, P.

    1977-01-01

    This work presents the theoretical concepts and experimental design of an electron gun. This gun is working in the weak energy range and the focus position is independant of electron energy measurements and analysis methods of the electron beam are described [fr

  19. Validation of tracker alignment using electrons, and search for long-lived particles in the electron-muon channel, in the CMS experiment at LHC

    International Nuclear Information System (INIS)

    Goetzmann, Christophe

    2014-01-01

    The first part of my work concerns the development of an algorithm using CMS data to automatically detect the presence of particular deformations than can occur in the CMS tracker. The method takes advantage of the bias that such deformations induce in the measurement of electron impulsion. The reliability of the method has been proved using Monte-Carlo simulation. The algorithm was then used to certify that none of the considered deformations affected the data recorded in 2012. The second part of my work consists of a statistical analysis of the data recorded by CMS, in order to look for evidence of the presence of exotic long-lived particles. The latter could manifest themselves through their decay to an electron and a muon. Such an observation would provide a strong clue of the existence of new physics. In the absence of any observation statistically significant, a Bayesian method is used to interpret this result in term of constraints on a supersymmetric model (MSSM). (author)

  20. Validity of electronic diet recording nutrient estimates compared to dietitian analysis of diet records: A randomized controlled trial

    Science.gov (United States)

    Background: Dietary intake assessment with diet records (DR) is a standard research and practice tool in nutrition. Manual entry and analysis of DR is time-consuming and expensive. New electronic tools for diet entry by clients and research participants may reduce the cost and effort of nutrient int...

  1. Validation of the Read Out Electronics for the CMS Muon Drift Chambers at Tests Beam in CERN/GIF

    CERN Document Server

    Fernández, C; Fouz-Iglesias, M C; Marin, J; Oller, J C; Willmott, C

    2002-01-01

    Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs.

  2. Phd study of reliability and validity: One step closer to a standardized music therapy assessment model

    DEFF Research Database (Denmark)

    Jacobsen, Stine Lindahl

    The paper will present a phd study concerning reliability and validity of music therapy assessment model “Assessment of Parenting Competences” (APC) in the area of families with emotionally neglected children. This study had a multiple strategy design with a philosophical base of critical realism...... and pragmatism. The fixed design for this study was a between and within groups design in testing the APCs reliability and validity. The two different groups were parents with neglected children and parents with non-neglected children. The flexible design had a multiple case study strategy specifically...

  3. Development of a Digital Citizenship Scale for Youth: A Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Zafer KUŞ

    2017-12-01

    Full Text Available The main objective of this study is to develop a valid and reliable scale for identifying digital citizenship perceptions of young people in the most common age groups. The study was conducted as a survey study. The study group of this study is composed of 438 people in Turkey who are among 16-24 age group with the highest rate of internet use in Turkey. An exploratory factor analysis was performed to determine the validity of the scale and the item discrimination powers were calculated. The total variance of the scale was determined that the scale had 8-factor structure and was found to be 49,70%. The internal consistency level was also calculated to determine the reliability of the scale. As a result, it can be said that this scale is a valid and reliable scale that can be used to determine the digital citizenship perceptions of young people.

  4. SU-F-T-74: Experimental Validation of Monaco Electron Monte Carlo Dose Calculation for Small Fields

    International Nuclear Information System (INIS)

    Varadhan; Way, S; Arentsen, L; Gerbi, B

    2016-01-01

    Purpose: To verify experimentally the accuracy of Monaco (Elekta) electron Monte Carlo (eMC) algorithm to calculate small field size depth doses, monitor units and isodose distributions. Methods: Beam modeling of eMC algorithm was performed for electron energies of 6, 9, 12 15 and 18 Mev for a Elekta Infinity Linac and all available ( 6, 10, 14 20 and 25 cone) applicator sizes. Electron cutouts of incrementally smaller field sizes (20, 40, 60 and 80% blocked from open cone) were fabricated. Dose calculation was performed using a grid size smaller than one-tenth of the R_8_0_–_2_0 electron distal falloff distance and number of particle histories was set at 500,000 per cm"2. Percent depth dose scans and beam profiles at dmax, d_9_0 and d_8_0 depths were measured for each cutout and energy with Wellhoffer (IBA) Blue Phantom"2 scanning system and compared against eMC calculated doses. Results: The measured dose and output factors of incrementally reduced cutout sizes (to 3cm diameter) agreed with eMC calculated doses within ± 2.5%. The profile comparisons at dmax, d_9_0 and d_8_0 depths and percent depth doses at reduced field sizes agreed within 2.5% or 2mm. Conclusion: Our results indicate that the Monaco eMC algorithm can accurately predict depth doses, isodose distributions, and monitor units in homogeneous water phantom for field sizes as small as 3.0 cm diameter for energies in the 6 to 18 MeV range at 100 cm SSD. Consequently, the old rule of thumb to approximate limiting cutout size for an electron field determined by the lateral scatter equilibrium (E (MeV)/2.5 in centimeters of water) does not apply to Monaco eMC algorithm.

  5. SU-F-T-74: Experimental Validation of Monaco Electron Monte Carlo Dose Calculation for Small Fields

    Energy Technology Data Exchange (ETDEWEB)

    Varadhan [Minneapolis Radiation Oncology, Fridley, MN (United States); Way, S [Minneapolis Radiation Oncology, Robbinsdale, MN (United States); Arentsen, L; Gerbi, B [University of Minnesota, Minneapolis, MN (United States)

    2016-06-15

    Purpose: To verify experimentally the accuracy of Monaco (Elekta) electron Monte Carlo (eMC) algorithm to calculate small field size depth doses, monitor units and isodose distributions. Methods: Beam modeling of eMC algorithm was performed for electron energies of 6, 9, 12 15 and 18 Mev for a Elekta Infinity Linac and all available ( 6, 10, 14 20 and 25 cone) applicator sizes. Electron cutouts of incrementally smaller field sizes (20, 40, 60 and 80% blocked from open cone) were fabricated. Dose calculation was performed using a grid size smaller than one-tenth of the R{sub 80–20} electron distal falloff distance and number of particle histories was set at 500,000 per cm{sup 2}. Percent depth dose scans and beam profiles at dmax, d{sub 90} and d{sub 80} depths were measured for each cutout and energy with Wellhoffer (IBA) Blue Phantom{sup 2} scanning system and compared against eMC calculated doses. Results: The measured dose and output factors of incrementally reduced cutout sizes (to 3cm diameter) agreed with eMC calculated doses within ± 2.5%. The profile comparisons at dmax, d{sub 90} and d{sub 80} depths and percent depth doses at reduced field sizes agreed within 2.5% or 2mm. Conclusion: Our results indicate that the Monaco eMC algorithm can accurately predict depth doses, isodose distributions, and monitor units in homogeneous water phantom for field sizes as small as 3.0 cm diameter for energies in the 6 to 18 MeV range at 100 cm SSD. Consequently, the old rule of thumb to approximate limiting cutout size for an electron field determined by the lateral scatter equilibrium (E (MeV)/2.5 in centimeters of water) does not apply to Monaco eMC algorithm.

  6. Electron spin resonance intercomparison studies on irradiated foodstuffs

    International Nuclear Information System (INIS)

    Raffi, J.

    1992-01-01

    The results of intercomparison studies organized by the Community Bureau of Reference on the use of electron spin resonance spectroscopy for the identification of irradiated food are presented. A qualitative intercomparison was carried out using beef and trout bones, sardine scales, pistachio nut shells, dried grapes and papaya. A quantitative intercomparison involving the use of poultry bones was also organized. There was no difficulty in identifying meat bones, dried grapes and papaya. In the case of fish bones there is a need for further kinetic studies using different fish species. The identification of pistachio nut shells is more complicated and further research is needed prior to the organization of a further intercomparison. Laboratories were able to distinguish between chicken bones irradiated in the range 1 to 3 KGy or 7 to 10 KGy although there was a partial overlap between the results from different laboratories

  7. Electron spin resonance intercomparison studies on irradiated foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Raffi, J [CEA Centre d` Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (FR)

    1992-07-01

    The results of intercomparison studies organized by the Community Bureau of Reference on the use of electron spin resonance spectroscopy for the identification of irradiated food are presented. A qualitative intercomparison was carried out using beef and trout bones, sardine scales, pistachio nut shells, dried grapes and papaya. A quantitative intercomparison involving the use of poultry bones was also organized. There was no difficulty in identifying meat bones, dried grapes and papaya. In the case of fish bones there is a need for further kinetic studies using different fish species. The identification of pistachio nut shells is more complicated and further research is needed prior to the organization of a further intercomparison. Laboratories were able to distinguish between chicken bones irradiated in the range 1 to 3 KGy or 7 to 10 KGy although there was a partial overlap between the results from different laboratories.

  8. Perceptions of Organizational Politics Scale (POPS Questionnaire into Turkish: A Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Evrim EROL

    2016-07-01

    Full Text Available In this study it was aimed to make the studies of the translation of Perception of Organizational Politics Scale into Turkish and the validity and reliability of the scale. Perceptions of Organizational Politics Scale’s (POPS validities has been tested in terms of view, content and structure. The application is designed as a two-stage process. In the first stage, face and content validity was tested. In the second stage, it was sought evidences for the construct validity of the scale by making exploratory factor analysis (EFA and then the confirmatory factor analysis (CFA to the data obtained. In determining the reliability of the scale item-total score correlations and Cronbach alpha coefficient was used. The application made for the validity and reliability of the scale was conducted on the data collected from 277 faculty members working in universities’ education faculties. As a method of achieving those faculty members "Simple randomized (random sampling" is used. The psychometric properties of the Turkish version of Perception of Organizational Politics Scale showed that the scale has a satisfactory level of reliability and validity for the Turkish employee sample.

  9. Construction and Validation of a Questionnaire to Study Future Teachers' Beliefs about Cultural Diversity

    Science.gov (United States)

    López López, M. Carmen; Hinojosa Pareja, Eva F.

    2016-01-01

    The article presents the construction and validation process of a questionnaire designed to study student teachers' beliefs about cultural diversity. The study, beyond highlighting the complexity involved in the study of beliefs, emphasises their relevance in implementing inclusive educational processes that guarantee the right to a good education…

  10. Validation of traffic-related air pollution exposure estimates for long-term studies

    NARCIS (Netherlands)

    Van Roosbroeck, S.

    2007-01-01

    This thesis describes a series of studies that investigate the validity of using outdoor concentrations and/or traffic-related indicator exposure variables as a measure for exposure assessment in epidemiological studies on the long-term effect of traffic-related air pollution. A pilot study was

  11. Simulation study on avoiding runaway electron generation by magnetic perturbations

    International Nuclear Information System (INIS)

    Tokuda, S.; Yoshino, R.; Matsumoto, T.; Hudson, S.R.; Kawano, Y.; Takizuka, T.

    2001-01-01

    Simulations have demonstrated that magnetic islands having the widths expected on the major disruption cause the collisionless loss of the relativistic electrons, and that the resultant loss rate is high enough to avoid or to suppress the runaway generation. It is because, for the magnetic fluctuations in the disruption, the loss of the electron confinement due to the breakdown of the toroidal momentum conservation overwhelms the runaway electron confinement due to the phase-averaging effect of relativistic electrons. Simulation results agree closely with recent experiments on fast plasma shutdown, showing that it is possible to prevent the generation of runaway electrons. (author)

  12. Volumetric Studies of Earth's Electron Foreshock Using PEACE Data

    Science.gov (United States)

    Goldstein, Melvyn L.; Gurgiolo, Chris; Fazakersley, Andrew

    2010-01-01

    We describe the methodology used to set up and compute spatial derivatives of the electron moments using data acquired by the Plasma Electron And Current Experiment (PEACE) electron data from the four Cluster spacecraft. The results are used to investigate electron vorticity in the foreshock. What is found is that much of the measured vorticity, under nominal conditions, appears to be caused by changes in the flow direction of the return (either reflected or leakage from the magnetosheath) and strahl electron populations as they couple to changes in the magnetic field orientation. This in turn results in deflections in the total bulk velocity.

  13. Electron Spin Resonance (ESR) studies of returned comet nucleus samples

    International Nuclear Information System (INIS)

    Tsay, Fundow; Kim, S.S.; Liang, R.H.

    1989-01-01

    The most important objective of the Comet Nucleus Sample Returm Mission is to return samples which could reflect formation conditions and evolutionary processes in the early solar nebula. It is expected that the returned samples will consist of fine-grained silicate materials mixed with ices composed of simple molecules such as H 2 O, NH 3 , CH 4 as well as organics and/or more complex compounds. Because of the exposure to ionizing radiation from cosmic-ray, gamma-ray, and solar wind protons at low temperature, free radicals are expected to be formed and trapped in the solid ice matrices. The kind of trapped radical species together with their concentration and thermal stability can be used as a dosimeter as well as a geothermometer to determine thermal and radiation histories as well as outgassing and other possible alternation effects since the nucleus material was formed. Since free radicals that are known to contain unpaired electrons are all paramagnetic in nature, they can be readily detected and characterized in their native form by the Electron Spin Resonance (ESR) method. In fact, ESR has been shown to be a non-destructive, highly sensitive tool for the detection and characterization of paramagnetic, ferromagnetic, and radiation damage centers in terrestrial and extraterrestrial geological samples. The potential use of ESR as an effective method in the study of returned comet nucleus samples, in particular, in the analysis of fine-grained solid state icy samples is discussed

  14. Study of an integrated electronic monitor for neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Barelaud, B.; Nexon-Mokhtari, F.; Barrau, C.; Decossas, J.L.; Vareille, J.C. [Limoges Univ., 87 (France); Sarrabayrouse, G.J. [CNRS, 31 - Toulouse (France)

    1995-12-31

    The majority of the individual neutron monitors measure incorrectly in a certain energy range (10 keV-500 keV). For electronic devices, this problem is due to their high {gamma} sensitivity. To solve this problem a microelectronic detector design for neutron spectrometry is now being studied at LEPOFI. It is based on the measurement of the total energy which is deposited by {sup 6}Li (n, {alpha}) {sup 3}H or {sup 10}B (n {alpha}) {sup 7}Li reactions in silicon detectors. A new electronic sensor - for example a boron or lithium sandwich device -has been developed in collaboration with LAAS. Specific techniques for silicon sensor coating with boron have been developed and are briefly presented. The response of the detector has been computed using a model and a code developed at LEPOFI. Several parameters have been taken into account in the calculations: the type of layer, its thickness, the characteristics of the detector. The results of these simulations are discussed and calculated pulse height distributions for various designs are presented. The present status of the investigation only concerns thermal neutrons. (author).

  15. Statistical studies of energetic electrons in the outer radiation belt

    Energy Technology Data Exchange (ETDEWEB)

    Johnstone, A.D.; Rodgers, D.J.; Jones, G.H. E-mail: g.h.jones@ic.ac.uk

    1999-10-01

    The medium electron A (MEA) instrument aboard the CRRES spacecraft provided data on terrestrial radiation belt electrons in the energy range from 153 to 1582 keV, during 1990-91. These data have previously been used to produce an empirical model of the radiation belts from L=1.1 to 8.9, ordered according to 17 energy bands, 18 pitch angle bins, and 5 Kp ranges. Empirical models such as this are very valuable, but are prone to statistical fluctuations and gaps in coverage. In this study, in order to smooth the data and make it more easy to interpolate within data gaps, the pitch angle distribution at each energy in the model was fitted with a Bessel function. This provided a way to characterize the pitch angle in terms of only two parameters for each energy. It was not possible to model fluxes reliably within the loss cone because of poor statistics. The fitted distributions give an indication of the way in which pitch angle diffusion varies in the outer radiation belts. The two parameters of the Bessel function were found to vary systematically with L value, energy and Kp. Through the fitting of a simple function to these systematic variations, the number of parameters required to describe the model could be reduced drastically.

  16. Electronic device for endosurgical skills training (EDEST): study of reliability.

    Science.gov (United States)

    Pagador, J B; Uson, J; Sánchez, M A; Moyano, J L; Moreno, J; Bustos, P; Mateos, J; Sánchez-Margallo, F M

    2011-05-01

    Minimally Invasive Surgery procedures are commonly used in many surgical practices, but surgeons need specific training models and devices due to its difficulty and complexity. In this paper, an innovative electronic device for endosurgical skills training (EDEST) is presented. A study on reliability for this device was performed. Different electronic components were used to compose this new training device. The EDEST was focused on two basic laparoscopic tasks: triangulation and coordination manoeuvres. A configuration and statistical software was developed to complement the functionality of the device. A calibration method was used to assure the proper work of the device. A total of 35 subjects (8 experts and 27 novices) were used to check the reliability of the system using the MTBF analysis. Configuration values for triangulation and coordination exercises were calculated as 0.5 s limit threshold and 800-11,000 lux range of light intensity, respectively. Zero errors in 1,050 executions (0%) for triangulation and 21 errors in 5,670 executions (0.37%) for coordination were obtained. A MTBF of 2.97 h was obtained. The results show that the reliability of the EDEST device is acceptable when used under previously defined light conditions. These results along with previous work could demonstrate that the EDEST device can help surgeons during first training stages.

  17. Positron annihilation and electron spin resonance studies of defects in electron-irradiated 3C-SiC

    International Nuclear Information System (INIS)

    Itoh, Hisayoshi; Yoshikawa, Masahito; Tanigawa, Shoichiro; Nashiyama, Isamu; Misawa, Shunji; Okumura, Hajime; Yoshida, Sadafumi.

    1992-01-01

    Defects induced by 1 MeV electron-irradiation in cubic silicon carbide (3C-SiC) epitaxially grown by chemical vapor deposition have been studied with positron annihilation and electron spin resonance (ESR). Doppler broadened energy spectra of annihilation γ-rays obtained by using variable-energy positron beams showed the formation of vacancy-type defects in 3C-SiC by the electron-irradiation. An ESR spectrum labeled Tl, which has an isotropic g-value of 2.0029 ± 0.001, was observed in electron-irradiated 3C-SiC. The Tl spectrum is interpreted by hyperfine interactions of paramagnetic electrons with 13 C at four carbon sites and 29 Si at twelve silicon sites, indicating that the Tl center arises from a point defect at a silicon site. Both the results can be accounted for by the introduction of isolated Si vacancies by the irradiation. (author)

  18. Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC-shaped fields

    International Nuclear Information System (INIS)

    Lloyd, Samantha A. M.; Gagne, Isabelle M.; Zavgorodni, Sergei; Bazalova-Carter, Magdalena

    2016-01-01

    Purpose: This work evaluates Varian’s electron phase–space sources for Monte Carlo simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined, modulated photon and electron radiation therapy (MPERT) where fields are shaped by the photon multileaf collimator (MLC) and delivered at 70 cm SSD. Methods: Monte Carlo simulations performed with EGSnrc-based BEAMnrc/DOSXYZnrc and PENELOPE-based PRIMO are compared against diode measurements for 5 × 5, 10 × 10, and 20 × 20 cm 2 MLC-shaped fields delivered with 6, 12, and 20 MeV electrons at 70 cm SSD (jaws set to 40 × 40 cm 2 ). Depth dose curves and profiles are examined. In addition, EGSnrc-based simulations of relative output as a function of MLC-field size and jaw-position are compared against ion chamber measurements for MLC-shaped fields between 3 × 3 and 25 × 25 cm 2 and jaw positions that range from the MLC-field size to 40 × 40 cm 2 . Results: Percent depth dose curves generated by BEAMnrc/DOSXYZnrc and PRIMO agree with measurement within 2%, 2 mm except for PRIMO’s 12 MeV, 20 × 20 cm 2 field where 90% of dose points agree within 2%, 2 mm. Without the distance to agreement, differences between measurement and simulation are as large as 7.3%. Characterization of simulated dose parameters such as FWHM, penumbra width and depths of 90%, 80%, 50%, and 20% dose agree within 2 mm of measurement for all fields except for the FWHM of the 6 MeV, 20 × 20 cm 2 field which falls within 2 mm distance to agreement. Differences between simulation and measurement exist in the profile shoulders and penumbra tails, in particular for 10 × 10 and 20 × 20 cm 2 fields of 20 MeV electrons, where both sets of simulated data fall short of measurement by as much as 3.5%. BEAMnrc/DOSXYZnrc simulated outputs agree with measurement within 2.3% except for 6 MeV MLC-shaped fields. Discrepancies here are as great as 5.5%. Conclusions: TrueBeam electron phase–spaces available from Varian have been

  19. Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC-shaped fields

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd, Samantha A. M. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8P 3P6 5C2 (Canada); Gagne, Isabelle M., E-mail: imgagne@bccancer.bc.ca; Zavgorodni, Sergei [Department of Medical Physics, BC Cancer Agency–Vancouver Island Centre, Victoria, British Columbia V8R 6V5, Canada and Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 3P6 5C2 (Canada); Bazalova-Carter, Magdalena [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 3P6 5C2 (Canada)

    2016-06-15

    Purpose: This work evaluates Varian’s electron phase–space sources for Monte Carlo simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined, modulated photon and electron radiation therapy (MPERT) where fields are shaped by the photon multileaf collimator (MLC) and delivered at 70 cm SSD. Methods: Monte Carlo simulations performed with EGSnrc-based BEAMnrc/DOSXYZnrc and PENELOPE-based PRIMO are compared against diode measurements for 5 × 5, 10 × 10, and 20 × 20 cm{sup 2} MLC-shaped fields delivered with 6, 12, and 20 MeV electrons at 70 cm SSD (jaws set to 40 × 40 cm{sup 2}). Depth dose curves and profiles are examined. In addition, EGSnrc-based simulations of relative output as a function of MLC-field size and jaw-position are compared against ion chamber measurements for MLC-shaped fields between 3 × 3 and 25 × 25 cm{sup 2} and jaw positions that range from the MLC-field size to 40 × 40 cm{sup 2}. Results: Percent depth dose curves generated by BEAMnrc/DOSXYZnrc and PRIMO agree with measurement within 2%, 2 mm except for PRIMO’s 12 MeV, 20 × 20 cm{sup 2} field where 90% of dose points agree within 2%, 2 mm. Without the distance to agreement, differences between measurement and simulation are as large as 7.3%. Characterization of simulated dose parameters such as FWHM, penumbra width and depths of 90%, 80%, 50%, and 20% dose agree within 2 mm of measurement for all fields except for the FWHM of the 6 MeV, 20 × 20 cm{sup 2} field which falls within 2 mm distance to agreement. Differences between simulation and measurement exist in the profile shoulders and penumbra tails, in particular for 10 × 10 and 20 × 20 cm{sup 2} fields of 20 MeV electrons, where both sets of simulated data fall short of measurement by as much as 3.5%. BEAMnrc/DOSXYZnrc simulated outputs agree with measurement within 2.3% except for 6 MeV MLC-shaped fields. Discrepancies here are as great as 5.5%. Conclusions: TrueBeam electron phase

  20. Electron beam interactions with CO on W[100] studied by Auger electron spectroscopy

    International Nuclear Information System (INIS)

    Housley, M.; King, D.A.

    1977-01-01

    The interaction of 2500 eV electrons with carbon monoxide chemisorbed on tungsten [100] was investigated by rapid-scan Auger electron spectroscopy. When no α state was present the O and C signals from the β state of CO were invariant during electron bombardment, giving an upper limit estimate for the electron stimulated desorption cross section, Qsub(β), of 2 x 10 -21 cm 2 . With the crystal at room temperature and saturated with CO, however, electron-beam induced accumulation of carbon was observed and characterised, the rate of the process being independent of CO pressure at pressures above 2 x 10 -8 Torr. At 450 K the rate was found to be pressure dependent up to at least 6 x 10 -7 Torr. A model is proposed for the accumulation process, which is based on electron beam dissociation of α 2 -CO to form adsorbed carbon and gaseous O and the creation of new sites for further α 2 -CO adsorption; it is in quantitative agreement with the results and yields a cross section for ESD of α 2 -CO (Qsub(α 2 )=1.55 X 10 -18 cm 2 ) in clo 2 e agreement with direct measurements. (Auth.)