WorldWideScience

Sample records for validation framework 2d

  1. A framework for automatic creation of gold-standard rigid 3D-2D registration datasets.

    Science.gov (United States)

    Madan, Hennadii; Pernuš, Franjo; Likar, Boštjan; Špiclin, Žiga

    2017-02-01

    Advanced image-guided medical procedures incorporate 2D intra-interventional information into pre-interventional 3D image and plan of the procedure through 3D/2D image registration (32R). To enter clinical use, and even for publication purposes, novel and existing 32R methods have to be rigorously validated. The performance of a 32R method can be estimated by comparing it to an accurate reference or gold standard method (usually based on fiducial markers) on the same set of images (gold standard dataset). Objective validation and comparison of methods are possible only if evaluation methodology is standardized, and the gold standard  dataset is made publicly available. Currently, very few such datasets exist and only one contains images of multiple patients acquired during a procedure. To encourage the creation of gold standard 32R datasets, we propose an automatic framework. The framework is based on rigid registration of fiducial markers. The main novelty is spatial grouping of fiducial markers on the carrier device, which enables automatic marker localization and identification across the 3D and 2D images. The proposed framework was demonstrated on clinical angiograms of 20 patients. Rigid 32R computed by the framework was more accurate than that obtained manually, with the respective target registration error below 0.027 mm compared to 0.040 mm. The framework is applicable for gold standard setup on any rigid anatomy, provided that the acquired images contain spatially grouped fiducial markers. The gold standard datasets and software will be made publicly available.

  2. Half-metallicity in 2D organometallic honeycomb frameworks

    Science.gov (United States)

    Sun, Hao; Li, Bin; Zhao, Jin

    2016-10-01

    Half-metallic materials with a high Curie temperature (T C) have many potential applications in spintronics. Magnetic metal free two-dimensional (2D) half-metallic materials with a honeycomb structure contain graphene-like Dirac bands with π orbitals and show excellent aspects in transport properties. In this article, by investigating a series of 2D organometallic frameworks with a honeycomb structure using first principles calculations, we study the origin of forming half-metallicity in this kind of 2D organometallic framework. Our analysis shows that charge transfer and covalent bonding are two crucial factors in the formation of half-metallicity in organometallic frameworks. (i) Sufficient charge transfer from metal atoms to the molecules is essential to form the magnetic centers. (ii) These magnetic centers need to be connected through covalent bonding, which guarantee the strong ferromagnetic (FM) coupling. As examples, the organometallic frameworks composed by (1,3,5)-benzenetricarbonitrile (TCB) molecules with noble metals (Au, Ag, Cu) show half-metallic properties with T C as high as 325 K. In these organometallic frameworks, the strong electronegative cyano-groups (CN groups) drive the charge transfer from metal atoms to the TCB molecules, forming the local magnetic centers. These magnetic centers experience strong FM coupling through the d-p covalent bonding. We propose that most of the 2D organometallic frameworks composed by molecule—CN—noble metal honeycomb structures contain similar half metallicity. This is verified by replacing TCB molecules with other organic molecules. Although the TCB-noble metal organometallic framework has not yet been synthesized, we believe the development of synthesizing techniques and facility will enable the realization of them. Our study provides new insight into the 2D half-metallic material design for the potential applications in nanotechnology.

  3. Half-metallicity in 2D organometallic honeycomb frameworks

    International Nuclear Information System (INIS)

    Sun, Hao; Li, Bin; Zhao, Jin

    2016-01-01

    Half-metallic materials with a high Curie temperature (T C ) have many potential applications in spintronics. Magnetic metal free two-dimensional (2D) half-metallic materials with a honeycomb structure contain graphene-like Dirac bands with π orbitals and show excellent aspects in transport properties. In this article, by investigating a series of 2D organometallic frameworks with a honeycomb structure using first principles calculations, we study the origin of forming half-metallicity in this kind of 2D organometallic framework. Our analysis shows that charge transfer and covalent bonding are two crucial factors in the formation of half-metallicity in organometallic frameworks. (i) Sufficient charge transfer from metal atoms to the molecules is essential to form the magnetic centers. (ii) These magnetic centers need to be connected through covalent bonding, which guarantee the strong ferromagnetic (FM) coupling. As examples, the organometallic frameworks composed by (1,3,5)-benzenetricarbonitrile (TCB) molecules with noble metals (Au, Ag, Cu) show half-metallic properties with T C as high as 325 K. In these organometallic frameworks, the strong electronegative cyano-groups (CN groups) drive the charge transfer from metal atoms to the TCB molecules, forming the local magnetic centers. These magnetic centers experience strong FM coupling through the d – p covalent bonding. We propose that most of the 2D organometallic frameworks composed by molecule—CN—noble metal honeycomb structures contain similar half metallicity. This is verified by replacing TCB molecules with other organic molecules. Although the TCB-noble metal organometallic framework has not yet been synthesized, we believe the development of synthesizing techniques and facility will enable the realization of them. Our study provides new insight into the 2D half-metallic material design for the potential applications in nanotechnology. (paper)

  4. Research on verification and validation strategy of detonation fluid dynamics code of LAD2D

    Science.gov (United States)

    Wang, R. L.; Liang, X.; Liu, X. Z.

    2017-07-01

    The verification and validation (V&V) is an important approach in the software quality assurance of code in complex engineering application. Reasonable and efficient V&V strategy can achieve twice the result with half the effort. This article introduces the software-Lagrangian adaptive hydrodynamics code in 2D space (LAD2D), which is self-developed software in detonation CFD with plastic-elastic structure. The V&V strategy of this detonation CFD code is presented based on the foundation of V&V methodology for scientific software. The basic framework of the module verification and the function validation is proposed, composing the detonation fluid dynamics model V&V strategy of LAD2D.

  5. Validation of DYSTOOL for unsteady aerodynamic modeling of 2D airfoils

    Science.gov (United States)

    González, A.; Gomez-Iradi, S.; Munduate, X.

    2014-06-01

    From the point of view of wind turbine modeling, an important group of tools is based on blade element momentum (BEM) theory using 2D aerodynamic calculations on the blade elements. Due to the importance of this sectional computation of the blades, the National Renewable Wind Energy Center of Spain (CENER) developed DYSTOOL, an aerodynamic code for 2D airfoil modeling based on the Beddoes-Leishman model. The main focus here is related to the model parameters, whose values depend on the airfoil or the operating conditions. In this work, the values of the parameters are adjusted using available experimental or CFD data. The present document is mainly related to the validation of the results of DYSTOOL for 2D airfoils. The results of the computations have been compared with unsteady experimental data of the S809 and NACA0015 profiles. Some of the cases have also been modeled using the CFD code WMB (Wind Multi Block), within the framework of a collaboration with ACCIONA Windpower. The validation has been performed using pitch oscillations with different reduced frequencies, Reynolds numbers, amplitudes and mean angles of attack. The results have shown a good agreement using the methodology of adjustment for the value of the parameters. DYSTOOL have demonstrated to be a promising tool for 2D airfoil unsteady aerodynamic modeling.

  6. Validation of DYSTOOL for unsteady aerodynamic modeling of 2D airfoils

    International Nuclear Information System (INIS)

    González, A; Gomez-Iradi, S; Munduate, X

    2014-01-01

    From the point of view of wind turbine modeling, an important group of tools is based on blade element momentum (BEM) theory using 2D aerodynamic calculations on the blade elements. Due to the importance of this sectional computation of the blades, the National Renewable Wind Energy Center of Spain (CENER) developed DYSTOOL, an aerodynamic code for 2D airfoil modeling based on the Beddoes-Leishman model. The main focus here is related to the model parameters, whose values depend on the airfoil or the operating conditions. In this work, the values of the parameters are adjusted using available experimental or CFD data. The present document is mainly related to the validation of the results of DYSTOOL for 2D airfoils. The results of the computations have been compared with unsteady experimental data of the S809 and NACA0015 profiles. Some of the cases have also been modeled using the CFD code WMB (Wind Multi Block), within the framework of a collaboration with ACCIONA Windpower. The validation has been performed using pitch oscillations with different reduced frequencies, Reynolds numbers, amplitudes and mean angles of attack. The results have shown a good agreement using the methodology of adjustment for the value of the parameters. DYSTOOL have demonstrated to be a promising tool for 2D airfoil unsteady aerodynamic modeling

  7. Driver. D530.2 – Tools for the Lessons Learned Framework

    NARCIS (Netherlands)

    Schaik, M.G. van; et al

    2016-01-01

    In this deliverable D530.2 “Tools for the Lessons Learned Framework” the overall lessons learned framework will be clarified based on the delivery D53.1 “Lessons Learned Framework Concept” and aligned with the deliverable D52.1 “Harmonized competence framework”. The Tools for the Lessons Learned

  8. 2D→3D polycatenated and 3D→3D interpenetrated metal–organic frameworks constructed from thiophene-2,5-dicarboxylate and rigid bis(imidazole) ligands

    Energy Technology Data Exchange (ETDEWEB)

    Erer, Hakan [Department of Chemistry, Faculty of Arts and Sciences, Eskişehir Osmangazi University, 26480 Eskişehir (Turkey); Yeşilel, Okan Zafer, E-mail: yesilel@ogu.edu.tr [Department of Chemistry, Faculty of Arts and Sciences, Eskişehir Osmangazi University, 26480 Eskişehir (Turkey); Arıcı, Mürsel [Department of Chemistry, Faculty of Arts and Sciences, Eskişehir Osmangazi University, 26480 Eskişehir (Turkey); Keskin, Seda [Department of Chemical and Biological Engineering, Koç University, İstanbul (Turkey); Büyükgüngör, Orhan [Department of Physics, Faculty of Arts and Sciences, Ondokuz Mayıs University, 55139 Samsun (Turkey)

    2014-02-15

    Hydrothermal reactions of rigid 1,4-bis(imidazol-1-yl)benzene (dib) and 1,4-bis(imidazol-1-yl)-2,5-dimethylbenzene (dimb) with deprotonated thiophene-2,5-dicarboxylic acid (H{sub 2}tdc) in the presence of Zn(II) and Cd(II) salts in H{sub 2}O produced three new metal–organic frameworks, namely, [Zn(µ-tdc)(H{sub 2}O)(µ-dib)]{sub n} (1), [Cd(µ-tdc)(H{sub 2}O)(µ-dib)]{sub n} (2), and ([Cd{sub 2}(µ{sub 3}-tdc){sub 2}(µ-dimb){sub 2}]·(H{sub 2}O)){sub n}(3). These MOFs were characterized by FT-IR spectroscopy, elemental, thermal (TG, DTA, DTG and DSC), and single-crystal X-ray diffraction analyses. Isomorphous complexes 1 and 2 reveal polycatenated 2D+2D→3D framework based on an undulated (4,4)-sql layer. Complex 3 exhibits a new 4-fold interpenetrating 3D framework with the point symbol of 6{sup 6}. Molecular simulations were used to assess the potentials of the complexes for H{sub 2} storage application. Moreover, these coordination polymers exhibit blue fluorescent emission bands in the solid state at room temperature. - Graphical abstract: In this study, hydrothermal reactions of rigid 1,4-bis(imidazol-1-yl)benzene (dib) and 1,4-bis(imidazol-1-yl)-2,5-dimethylbenzene (dimb) with deprotonated thiophene-2,5-dicarboxylic acid (H{sub 2}tdc) in the presence of Zn(II) and Cd(II) salts in H{sub 2}O produced three new metal–organic frameworks. Isomorphous complexes 1 and 2 reveal polycatenated 2D+2D→3D framework based on an undulated (4,4)-sql layer. Complex 3 exhibits a new 4-fold interpenetrating 3D framework with the point symbol of 6{sup 6}. Molecular simulations were used to assess the potentials of the complexes for H{sub 2} storage application. These coordination polymers exhibit blue fluorescent emission bands in the solid state at room temperature. Display Omitted - Highlights: • Complexes 1 and 2 display polycatenated 2D+2D→3D framework. • Complex 3 exhibits a new 4-fold interpenetrating 3D framework. • Complex 1 adsorbs the highest amount of

  9. Production process validation of 2-[18F]-fluoro-2-deoxy-D-glucose

    International Nuclear Information System (INIS)

    Cantero, Miguel; Iglesias, Rocio; Aguilar, Juan; Sau, Pablo; Tardio, Evaristo; Narrillos, Marcos

    2003-01-01

    The main of validation of production process of 2-[18F]-fluoro-2-deoxi-D-glucose (FDG) was to check: A) equipment's and services implicated in the production process were correctly installed, well documented, and worked properly, and B) production of FDG was done in a repetitive way according to predefined parameters. The main document was the Validation Master Plan, and steps were: installation qualification, operation qualification, process qualification and validation report. After finalization of all tests established in qualification steps without deviations, we concluded that the production process was validated because is done in a repetitive way according predefined parameters (Au)

  10. Production process validation of 2-[18F]-fluoro-2-deoxy-D-glucose

    International Nuclear Information System (INIS)

    Cantero, Miguel; Iglesias, Rocio; Aguilar, Juan; Sau, Pablo; Tardio, Evaristo; Narrillos, Marcos

    2003-01-01

    The aim of production process validation of 2-[18F]-fluoro-2-deoxi-D-glucose (FDG) was to check: A) equipments and services implicated in the production process were correctly installed, well documented, and worked properly, and B) production of FDG was done in a repetitive way according to predefined parameters. The main document was the Validation Master Plan, and steps were: installation qualification, operational qualification, performance qualification and validation final report. After finalization of all tests established in qualification steps without deviations, we concluded that the production process was validated because consistently produced FDG meeting its pre-determined specifications and quality characteristics (Au)

  11. DESCQA: Synthetic Sky Catalog Validation Framework

    Science.gov (United States)

    Mao, Yao-Yuan; Uram, Thomas D.; Zhou, Rongpu; Kovacs, Eve; Ricker, Paul M.; Kalmbach, J. Bryce; Padilla, Nelson; Lanusse, François; Zu, Ying; Tenneti, Ananth; Vikraman, Vinu; DeRose, Joseph

    2018-04-01

    The DESCQA framework provides rigorous validation protocols for assessing the quality of high-quality simulated sky catalogs in a straightforward and comprehensive way. DESCQA enables the inspection, validation, and comparison of an inhomogeneous set of synthetic catalogs via the provision of a common interface within an automated framework. An interactive web interface is also available at portal.nersc.gov/project/lsst/descqa.

  12. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    International Nuclear Information System (INIS)

    Spiegel, M; Hornegger, J; Redel, T; Struffert, T; Doerfler, A

    2011-01-01

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  13. Concept, production and validation of a 3D-printed coil frame for the UST2 modular stellarator

    International Nuclear Information System (INIS)

    Queral, V.

    2014-01-01

    Highlights: •A construction method for stellarator modular coils is developed and validated. •3D printed truss structure filled and moulded with a material able to solidify. •The structure capability for forces in small stellarators has been estimated. •A light bare truss frame and a covered rigid double hull frame have been tested. -- Abstract: Geometric complexity of stellarators hampers a straightforward production of conceived optimised magnetic configurations. Integration of the engineering design with new fabrication methods may reduce the production cost and accelerate the production process. A fast cycle production of experimental fusion devices also might result in a faster advance in fusion plasma science. Several different stellarators could be used to test configurations for improved turbulent transport or to validate new divertor configurations. In this framework, and based on the results from the previously built UST 1 stellarator, the present work try to study and validate the feasibility of 3D printing methods (additive manufacturing) for small experimental stellarators. The paper summarises the engineering development, fabrication and validation of a coil frame test sector for the UST 2 stellarator. The definition of the Last Closed Flux Surface and winding surface for the test sector is based on an optimised quasi-isodynamic poloidal stellarator, modified for enhanced in-vessel remote handling manipulation and wide space for divertors. A Filled-sparse coil frame concept is developed to still keep low the cost in spite of the present expensive 3D printing materials and printers

  14. The Validity of a New Low-Dose Stereoradiography System to Perform 2D and 3D Knee Prosthetic Alignment Measurements

    OpenAIRE

    Meijer, Marrigje F.; Velleman, Ton; Boerboom, Alexander L.; Bulstra, Sjoerd K.; Otten, Egbert; Stevens, Martin; Reininga, Inge H. F.

    2016-01-01

    Introduction The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D. Methods EOS images were made of a lower limb phantom containing a knee prosthesis, while varying VV angle from 15 degrees varus to 15 degrees valgus and flexion a...

  15. 3D vs 2D laparoscopic systems: Development of a performance quantitative validation model.

    Science.gov (United States)

    Ghedi, Andrea; Donarini, Erica; Lamera, Roberta; Sgroi, Giovanni; Turati, Luca; Ercole, Cesare

    2015-01-01

    The new technology ensures 3D laparoscopic vision by adding depth to the traditional two dimensions. This realistic vision gives the surgeon the feeling of operating in real space. Hospital of Treviglio-Caravaggio isn't an university or scientific institution; in 2014 a new 3D laparoscopic technology was acquired therefore it led to evaluation of the of the appropriateness in term of patient outcome and safety. The project aims at achieving the development of a quantitative validation model that would ensure low cost and a reliable measure of the performance of 3D technology versus 2D mode. In addition, it aims at demonstrating how new technologies, such as open source hardware and software and 3D printing, could help research with no significant cost increase. For these reasons, in order to define criteria of appropriateness in the use of 3D technologies, it was decided to perform a study to technically validate the use of the best technology in terms of effectiveness, efficiency and safety in the use of a system between laparoscopic vision in 3D and the traditional 2D. 30 surgeons were enrolled in order to perform an exercise through the use of laparoscopic forceps inside a trainer. The exercise consisted of having surgeons with different level of seniority, grouped by type of specialization (eg. surgery, urology, gynecology), exercising videolaparoscopy with two technologies (2D and 3D) through the use of a anthropometric phantom. The target assigned to the surgeon was that to pass "needle and thread" without touching the metal part in the shortest time possible. The rings selected for the exercise had each a coefficient of difficulty determined by depth, diameter, angle from the positioning and from the point of view. The analysis of the data collected from the above exercise has mathematically confirmed that the 3D technique ensures a learning curve lower in novice and greater accuracy in the performance of the task with respect to 2D.

  16. Toward a Unified Validation Framework in Mixed Methods Research

    Science.gov (United States)

    Dellinger, Amy B.; Leech, Nancy L.

    2007-01-01

    The primary purpose of this article is to further discussions of validity in mixed methods research by introducing a validation framework to guide thinking about validity in this area. To justify the use of this framework, the authors discuss traditional terminology and validity criteria for quantitative and qualitative research, as well as…

  17. Anion-induced structural transformation of a sulfate-incorporated 2D Cd(II)–organic framework

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Li-Wei [Institute of Chemistry, Academia Sinica, Taipei 115, Taiwan (China); Institute of Materials Science and Engineering, National Central University, Taoyuan 320, Taiwan (China); Luo, Tzuoo-Tsair [Institute of Chemistry, Academia Sinica, Taipei 115, Taiwan (China); Wang, Chih-Min [Department of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung 202, Taiwan (China); Lee, Gene-Hsiang; Peng, Shie-Ming [Department of Chemistry, National Taiwan University, Taipei 107, Taiwan (China); Liu, Yen-Hsiang [Department of Chemistry, Fu Jen Catholic University, New Taipei City 242, Taiwan (China); Lee, Sheng-Long [Institute of Materials Science and Engineering, National Central University, Taoyuan 320, Taiwan (China); Lu, Kuang-Lieh [Institute of Chemistry, Academia Sinica, Taipei 115, Taiwan (China)

    2016-07-15

    A Cd(II)–organic framework {[Cd_2(tpim)_4(SO_4)(H_2O)_2]·(SO_4)·21H_2O}{sub n} (1) was synthesized by reacting CdSO{sub 4}·8/3H{sub 2}O and 2,4,5-tri(4-pyridyl)imidazole (tpim) under hydrothermal conditions. A structural analysis showed that compound 1 adopts a layered structure in which the [Cd(tpim){sub 2}]{sub n} chains are linked by sulfate anions. These 2D layers are further packed into a 3D supramolecular framework via π–π interactions. The structure contains two types of SO{sub 4}{sup 2−} anions, i.e., bridging SO{sub 4}{sup 2−} and free SO{sub 4}{sup 2−} anions, the latter of which are included in the large channels of the framework. Compound 1 exhibits interesting anion exchange behavior. In the presence of SCN{sup −} anions, both the bridging and free SO{sub 4}{sup 2−} anions in 1 were completely exchanged by SCN{sup −} ligands to form a 1D species [Cd(tpim){sub 2}(SCN){sub 2}] (1A), in which the SCN{sup –} moieties function as a monodentate ligand. On the other hand, when compound 1 was ion exchanged with N{sub 3}{sup −} anions in aqueous solution, the bridging SO{sub 4}{sup 2−} moieties remained intact, and only the free guest SO{sub 4}{sup 2−} were replaced by N{sub 3}{sup −} anions. The gas adsorption behavior of the activated compound 1 was also investigated. - Highlights: • An interesting anion-induced structural transformation of a sulfate-incorporated 2D Cd(II)–organic framework is reported. • The sulfate-incorporated 2D layer compound exhibits very different anion exchange behavior with respect to SCN{sup −} and N{sub 3}{sup −}. • Both the bridging and free SO{sub 4}{sup 2−} anions in the 2D structure were completely exchanged by SCN{sup −} ligands, resulting in the formation of a 1D species. However, in the case of N{sub 3}{sup −} anions, only the free guest SO{sub 4}{sup 2−} in the structure was replaced.

  18. New coordination polymers from 1D chain, 2D layer to 3D framework constructed from 1,2-phenylenediacetic acid and 1,3-bis(4-pyridyl)propane flexible ligands

    International Nuclear Information System (INIS)

    Xin Lingyun; Liu Guangzhen; Wang Liya

    2011-01-01

    The hydrothermal reactions of Cd, Zn, or Cu(II) acetate salts with H 2 PHDA and BPP flexible ligands afford three new coordination polymers, including [Cd(PHDA)(BPP)(H 2 O)] n (1), [Zn(PHDA)(BPP)] n (2), and [Cu 2 (PHDA) 2 (BPP)] n (3) (H 2 PHDA=1,2-phenylenediacetic acid, BPP=1,3-bis(4-pyridyl)propane). The single-crystal X-ray diffractions reveal that all three complexes feature various metal carboxylate subunits extended further by the BPP ligands to form a diverse range of structures, displaying a remarked structural sensitivity to metal(II) cation. Complex 1 containing PHDA-bridged binuclear cadmium generates 1D double-stranded chain, complex 2 results in 2D→2D interpenetrated (4,4) grids, and complex 3 displays a 3D self-penetrated framework with 4 8 6 6 8 rob topology. In addition, fluorescent analyses show that both 1 and 2 exhibit intense blue-violet photoluminescence in the solid state. - Graphical Abstract: We show diverse supramolecular frameworks based on the same ligands (PHDA and BPP) and different metal acetate salts including 1D double-stranded chain, 2D2D twofold interpenetrated layer, and 3D self-penetration networks. Highlights: → Three metal(II = 2 /* ROMAN ) coordination polymers were synthesized using H 2 PHDA and BPP. → The diversity of structures show a remarked sensitivity to metal(II) center. → Complexes show the enhancement of fluorescence compared to that of free ligand.

  19. Concept, production and validation of a 3D-printed coil frame for the UST{sub 2} modular stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Queral, V., E-mail: vicentemanuel.queral@ciemat.es

    2014-10-15

    Highlights: •A construction method for stellarator modular coils is developed and validated. •3D printed truss structure filled and moulded with a material able to solidify. •The structure capability for forces in small stellarators has been estimated. •A light bare truss frame and a covered rigid double hull frame have been tested. -- Abstract: Geometric complexity of stellarators hampers a straightforward production of conceived optimised magnetic configurations. Integration of the engineering design with new fabrication methods may reduce the production cost and accelerate the production process. A fast cycle production of experimental fusion devices also might result in a faster advance in fusion plasma science. Several different stellarators could be used to test configurations for improved turbulent transport or to validate new divertor configurations. In this framework, and based on the results from the previously built UST{sub 1} stellarator, the present work try to study and validate the feasibility of 3D printing methods (additive manufacturing) for small experimental stellarators. The paper summarises the engineering development, fabrication and validation of a coil frame test sector for the UST{sub 2} stellarator. The definition of the Last Closed Flux Surface and winding surface for the test sector is based on an optimised quasi-isodynamic poloidal stellarator, modified for enhanced in-vessel remote handling manipulation and wide space for divertors. A Filled-sparse coil frame concept is developed to still keep low the cost in spite of the present expensive 3D printing materials and printers.

  20. The Validity of a New Low-Dose Stereoradiography System to Perform 2D and 3D Knee Prosthetic Alignment Measurements.

    Science.gov (United States)

    Meijer, Marrigje F; Velleman, Ton; Boerboom, Alexander L; Bulstra, Sjoerd K; Otten, Egbert; Stevens, Martin; Reininga, Inge H F

    2016-01-01

    The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D. EOS images were made of a lower limb phantom containing a knee prosthesis, while varying VV angle from 15° varus to 15° valgus and flexion angle from 0° to 20°, and changing rotation from 20° internal to 20° external rotation. Differences between the actual VV position of the lower limb phantom and its position as measured on EOS 2D and 3D images were investigated. Rotation, flexion or VV angle alone had no major impact on VV2D or VV3D. Combination of VV angle and rotation with full extension did not show major differences in VV2D measurements either. Combination of flexion and rotation with a neutral VV angle showed variation of up to 7.4° for VV2D; maximum variation for VV3D was only 1.5°. A combination of the three variables showed an even greater distortion of VV2D, while VV3D stayed relatively constant. Maximum measurement difference between preset VV angle and VV2D was 9.8°, while the difference with VV3D was only 1.9°. The largest differences between the preset VV angle and VV2D were found when installing the leg in extreme angles, for example 15° valgus, 20° flexion and 20° internal rotation. After TKA, EOS VV3D were more valid than VV2D, indicating that 3D measurements compensate for malpositioning during acquisition. Caution is warranted when measuring VV angle on a conventional radiograph of a knee with a flexion contracture, varus or valgus angle and/or rotation of the knee joint during acquisition.

  1. Nature-Inspired 2D-Mosaic 3D-Gradient Mesoporous Framework: Bimetal Oxide Dual-Composite Strategy toward Ultrastable and High-Capacity Lithium Storage.

    Science.gov (United States)

    Yu, Jia; Wang, Yanlei; Mou, Lihui; Fang, Daliang; Chen, Shimou; Zhang, Suojiang

    2018-02-27

    In allusion to traditional transition-metal oxide (TMO) anodes for lithium-ion batteries, which face severe volume variation and poor conductivity, herein a bimetal oxide dual-composite strategy based on two-dimensional (2D)-mosaic three-dimensional (3D)-gradient design is proposed. Inspired by natural mosaic dominance phenomena, Zn 1-x Co x O/ZnCo 2 O 4 2D-mosaic-hybrid mesoporous ultrathin nanosheets serve as building blocks to assemble into a 3D Zn-Co hierarchical framework. Moreover, a series of derivative frameworks with high evolution are controllably synthesized, based on which a facile one-pot synthesis process can be developed. From a component-composite perspective, both Zn 1-x Co x O and ZnCo 2 O 4 provide superior conductivity due to bimetal doping effect, which is verified by density functional theory calculations. From a structure-composite perspective, 2D-mosaic-hybrid mode gives rise to ladder-type buffering and electrochemical synergistic effect, thus realizing mutual stabilization and activation between the mosaic pair, especially for Zn 1-x Co x O with higher capacity yet higher expansion. Moreover, the inside-out Zn-Co concentration gradient in 3D framework and rich oxygen vacancies further greatly enhance Li storage capability and stability. As a result, a high reversible capacity (1010 mA h g -1 ) and areal capacity (1.48 mA h cm -2 ) are attained, while ultrastable cyclability is obtained during high-rate and long-term cycles, rending great potential of our 2D-mosaic 3D-gradient design together with facile synthesis.

  2. A conceptual framework for homeostasis: development and validation

    Science.gov (United States)

    Wenderoth, Mary Pat; Michael, Joel; Cliff, William; Wright, Ann; Modell, Harold

    2016-01-01

    We have developed and validated a conceptual framework for understanding and teaching organismal homeostasis at the undergraduate level. The resulting homeostasis conceptual framework details critical components and constituent ideas underlying the concept of homeostasis. It has been validated by a broad range of physiology faculty members from community colleges, primarily undergraduate institutions, research universities, and medical schools. In online surveys, faculty members confirmed the relevance of each item in the framework for undergraduate physiology and rated the importance and difficulty of each. The homeostasis conceptual framework was constructed as a guide for teaching and learning of this critical core concept in physiology, and it also paves the way for the development of a concept inventory for homeostasis. PMID:27105740

  3. 3D-printed fusion components concepts and validation for the UST-2 stellarator

    International Nuclear Information System (INIS)

    Queral, V.

    2015-01-01

    Highlights: • A fabrication method for fusion components is developed and validated. • Synergies obtained from additive manufacturing and non-metal casting. • 3D-printed polyamide hollow truss structure and casting of acrylic resin tested. • UST- 2 stellarator coil frame fabricated to validate the method performance. - Abstract: The geometric complexity and high accuracy simultaneously required in magnetic fusion devices, particularly stellarators and tokamaks, hampers the production of fusion components and devices. Rapid manufacturing construction methods, particularly enhanced for fusion, may contribute to a faster cycle and lower cost production of certain components for tokamaks and stellarators. Casting, cutting, forming, welding and mechanising are conventional production techniques for major fusion components, i.e. coil casings, coil frames, vacuum vessels and blankets. Synergies may emerge by combination of additive manufacturing (3D printing) with conventional manufacturing methods. 3D printing combined with resin moulding is tested by construction of the coil frame and the vacuum vessel of a small stellarator, UST-2. Satisfactory coil frames have been obtained by moulding acrylic resin in a special 3D printed polyamide hollow three-dimensional structure. The conceptual engineering design, construction process and validation of the components are described. The presented manufacturing method might contribute to advance the future 3D printing of larger metallic components for fusion.

  4. 3D-printed fusion components concepts and validation for the UST-2 stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Queral, V., E-mail: vicentemanuel.queral@ciemat.es

    2015-10-15

    Highlights: • A fabrication method for fusion components is developed and validated. • Synergies obtained from additive manufacturing and non-metal casting. • 3D-printed polyamide hollow truss structure and casting of acrylic resin tested. • UST- 2 stellarator coil frame fabricated to validate the method performance. - Abstract: The geometric complexity and high accuracy simultaneously required in magnetic fusion devices, particularly stellarators and tokamaks, hampers the production of fusion components and devices. Rapid manufacturing construction methods, particularly enhanced for fusion, may contribute to a faster cycle and lower cost production of certain components for tokamaks and stellarators. Casting, cutting, forming, welding and mechanising are conventional production techniques for major fusion components, i.e. coil casings, coil frames, vacuum vessels and blankets. Synergies may emerge by combination of additive manufacturing (3D printing) with conventional manufacturing methods. 3D printing combined with resin moulding is tested by construction of the coil frame and the vacuum vessel of a small stellarator, UST-2. Satisfactory coil frames have been obtained by moulding acrylic resin in a special 3D printed polyamide hollow three-dimensional structure. The conceptual engineering design, construction process and validation of the components are described. The presented manufacturing method might contribute to advance the future 3D printing of larger metallic components for fusion.

  5. The Validity of a New Low-Dose Stereoradiography System to Perform 2D and 3D Knee Prosthetic Alignment Measurements.

    Directory of Open Access Journals (Sweden)

    Marrigje F Meijer

    Full Text Available The EOS stereoradiography system has shown to provide reliable varus/valgus (VV measurements of the lower limb in 2D (VV2D and 3D (VV3D after total knee arthroplasty (TKA. Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D.EOS images were made of a lower limb phantom containing a knee prosthesis, while varying VV angle from 15° varus to 15° valgus and flexion angle from 0° to 20°, and changing rotation from 20° internal to 20° external rotation. Differences between the actual VV position of the lower limb phantom and its position as measured on EOS 2D and 3D images were investigated.Rotation, flexion or VV angle alone had no major impact on VV2D or VV3D. Combination of VV angle and rotation with full extension did not show major differences in VV2D measurements either. Combination of flexion and rotation with a neutral VV angle showed variation of up to 7.4° for VV2D; maximum variation for VV3D was only 1.5°. A combination of the three variables showed an even greater distortion of VV2D, while VV3D stayed relatively constant. Maximum measurement difference between preset VV angle and VV2D was 9.8°, while the difference with VV3D was only 1.9°. The largest differences between the preset VV angle and VV2D were found when installing the leg in extreme angles, for example 15° valgus, 20° flexion and 20° internal rotation.After TKA, EOS VV3D were more valid than VV2D, indicating that 3D measurements compensate for malpositioning during acquisition. Caution is warranted when measuring VV angle on a conventional radiograph of a knee with a flexion contracture, varus or valgus angle and/or rotation of the knee joint during acquisition.

  6. The Validity of a New Low-Dose Stereoradiography System to Perform 2D and 3D Knee Prosthetic Alignment Measurements

    NARCIS (Netherlands)

    Meijer, Marrigje F.; Velleman, Ton; Boerboom, Alexander L.; Bulstra, Sjoerd K.; Otten, Egbert; Stevens, Martin; Reininga, Inge H. F.

    2016-01-01

    Introduction The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to

  7. A conceptual framework for homeostasis: development and validation.

    Science.gov (United States)

    McFarland, Jenny; Wenderoth, Mary Pat; Michael, Joel; Cliff, William; Wright, Ann; Modell, Harold

    2016-06-01

    We have developed and validated a conceptual framework for understanding and teaching organismal homeostasis at the undergraduate level. The resulting homeostasis conceptual framework details critical components and constituent ideas underlying the concept of homeostasis. It has been validated by a broad range of physiology faculty members from community colleges, primarily undergraduate institutions, research universities, and medical schools. In online surveys, faculty members confirmed the relevance of each item in the framework for undergraduate physiology and rated the importance and difficulty of each. The homeostasis conceptual framework was constructed as a guide for teaching and learning of this critical core concept in physiology, and it also paves the way for the development of a concept inventory for homeostasis. Copyright © 2016 The American Physiological Society.

  8. Multi-Objective Resource Allocation Scheme for D2D Multicast with QoS Guarantees in Cellular Networks

    Directory of Open Access Journals (Sweden)

    Fangmin Li

    2016-09-01

    Full Text Available Device-to-device (D2D multicast communication can greatly improve the spectrum utilization in a content delivery scenario. However, the co-channel interference and power consumption brought by D2D bring new challenges. All the D2D multicast groups expect to achieve a higher system capacity with less extra energy cost. In this paper, we investigate the uplink resource allocation issue when D2D multicast groups share the resources with other cellular uses (CUs, while guaranteeing a certain level of quality of service (QoS to CUs and D2D users. Firstly we address a flexible tradeoff framework in which the system power consumption and the system capacity (i.e., the number of admitted D2D links are assigned with different weight factors so that these two objectives are jointly considered. Then we propose an efficient resource optimization scheme, which comprises sub-channel allocation and signal-to-interference- plus-noise ratio (SINR assignment. Numerical results validate the effectiveness of the proposed framework, and demonstrate the advantages in dealing with the proposed multi-objective optimization problem.

  9. Synthesis and structure of a 2D → 3D framework with coexistence of hydrogen bonds and polythreading character

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ming-Dao, E-mail: matchlessjimmy@163.com; Zhuang, Qi-Fan; Xu, Jing; Cao, Hui, E-mail: yccaoh@hotmail.com [Nanjing University of Information Science & Technology, Jiangsu Key Laboratory of Atmospheric Environment Monitoring and Pollution Control, Collaborative Innovation Center for Atmospheric Environment & Equipment Technology, School of Environmental Science and Engineering (China)

    2015-12-15

    The title complex, ([Co(BPPA)(5-OH-bdc)] · (H{sub 2}O)){sub n} was prepared under hydrothermal conditions based on two ligands, namely, bis(4-(pyridin-4-yl)phenyl)amine (BPPA) and 5-hydroxyisophthalic acid (5-OH-H{sub 2}bdc). 5-OH-bdc{sup 2–} anions coordinated to Co atoms to give layers in crystal. BPPA ligands coordinate to Co atoms and thread into the adjacent layers. There are hydrogen bonds between adjacent layers, giving rise to a 2D → 3D framework.

  10. Validation of the entire 2D array Octavius by radiochromic films

    International Nuclear Information System (INIS)

    Iriondo Igerabide, U.; Former Forner, A.; Otal Palacin, A.; Martin Albina, M. L.; Lozares Cordero, S.; Maneru Camara, F.; Pellejero Pellejero, S.; Miquelez Alonso, S.; Soto Prados, P. M.; Rubio Arroniz, A.

    2011-01-01

    We have validated the 2D-array Octavius set for verification of IMRT plans complete, radiating with the same angles of incidence in the patient's actual plan. This has been taken as reference measurements with radiochromic films, since they are almost isotropic response, higher resolution and we already have experience with them.

  11. 1D helix, 2D brick-wall and herringbone, and 3D interpenetration d10 metal-organic framework structures assembled from pyridine-2,6-dicarboxylic acid N-oxide.

    Science.gov (United States)

    Wen, Li-Li; Dang, Dong-Bin; Duan, Chun-Ying; Li, Yi-Zhi; Tian, Zheng-Fang; Meng, Qing-Jin

    2005-10-03

    Five novel interesting d(10) metal coordination polymers, [Zn(PDCO)(H2O)2]n (PDCO = pyridine-2,6-dicarboxylic acid N-oxide) (1), [Zn2(PDCO)2(4,4'-bpy)2(H2O)2.3H2O]n (bpy = bipyridine) (2), [Zn(PDCO)(bix)]n (bix = 1,4-bis(imidazol-1-ylmethyl)benzene) (3), [Zn(PDCO)(bbi).0.5H2O]n (bbi = 1,1'-(1,4-butanediyl)bis(imidazole)) (4), and [Cd(PDCO)(bix)(1.5).1.5H2O]n (5), have been synthesized under hydrothermal conditions and structurally characterized. Polymer 1 possesses a one-dimensional (1D) helical chainlike structure with 4(1) helices running along the c-axis with a pitch of 10.090 Angstroms. Polymer 2 has an infinite chiral two-dimensional (2D) brick-wall-like layer structure in the ac plane built from achiral components, while both 3 and 4 exhibit an infinite 2D herringbone architecture, respectively extended in the ac and ab plane. Polymer 5 features a most remarkable and unique three-dimensional (3D) porous framework with 2-fold interpenetration related by symmetry, which contains channels in the b and c directions, both distributed in a rectangular grid fashion. Compounds 1-5, with systematic variation in dimensionality from 1D to 2D to 3D, are the first examples of d(10) metal coordination polymers into which pyridinedicarboxylic acid N-oxide has been introduced. In addition, polymers 1, 4, and 5 display strong blue fluorescent emissions in the solid state. Polymer 3 exhibits a strong SHG response, estimated to be approximately 0.9 times that of urea.

  12. Functional validation and comparison framework for EIT lung imaging.

    Science.gov (United States)

    Grychtol, Bartłomiej; Elke, Gunnar; Meybohm, Patrick; Weiler, Norbert; Frerichs, Inéz; Adler, Andy

    2014-01-01

    Electrical impedance tomography (EIT) is an emerging clinical tool for monitoring ventilation distribution in mechanically ventilated patients, for which many image reconstruction algorithms have been suggested. We propose an experimental framework to assess such algorithms with respect to their ability to correctly represent well-defined physiological changes. We defined a set of clinically relevant ventilation conditions and induced them experimentally in 8 pigs by controlling three ventilator settings (tidal volume, positive end-expiratory pressure and the fraction of inspired oxygen). In this way, large and discrete shifts in global and regional lung air content were elicited. We use the framework to compare twelve 2D EIT reconstruction algorithms, including backprojection (the original and still most frequently used algorithm), GREIT (a more recent consensus algorithm for lung imaging), truncated singular value decomposition (TSVD), several variants of the one-step Gauss-Newton approach and two iterative algorithms. We consider the effects of using a 3D finite element model, assuming non-uniform background conductivity, noise modeling, reconstructing for electrode movement, total variation (TV) reconstruction, robust error norms, smoothing priors, and using difference vs. normalized difference data. Our results indicate that, while variation in appearance of images reconstructed from the same data is not negligible, clinically relevant parameters do not vary considerably among the advanced algorithms. Among the analysed algorithms, several advanced algorithms perform well, while some others are significantly worse. Given its vintage and ad-hoc formulation backprojection works surprisingly well, supporting the validity of previous studies in lung EIT.

  13. Functional validation and comparison framework for EIT lung imaging.

    Directory of Open Access Journals (Sweden)

    Bartłomiej Grychtol

    Full Text Available INTRODUCTION: Electrical impedance tomography (EIT is an emerging clinical tool for monitoring ventilation distribution in mechanically ventilated patients, for which many image reconstruction algorithms have been suggested. We propose an experimental framework to assess such algorithms with respect to their ability to correctly represent well-defined physiological changes. We defined a set of clinically relevant ventilation conditions and induced them experimentally in 8 pigs by controlling three ventilator settings (tidal volume, positive end-expiratory pressure and the fraction of inspired oxygen. In this way, large and discrete shifts in global and regional lung air content were elicited. METHODS: We use the framework to compare twelve 2D EIT reconstruction algorithms, including backprojection (the original and still most frequently used algorithm, GREIT (a more recent consensus algorithm for lung imaging, truncated singular value decomposition (TSVD, several variants of the one-step Gauss-Newton approach and two iterative algorithms. We consider the effects of using a 3D finite element model, assuming non-uniform background conductivity, noise modeling, reconstructing for electrode movement, total variation (TV reconstruction, robust error norms, smoothing priors, and using difference vs. normalized difference data. RESULTS AND CONCLUSIONS: Our results indicate that, while variation in appearance of images reconstructed from the same data is not negligible, clinically relevant parameters do not vary considerably among the advanced algorithms. Among the analysed algorithms, several advanced algorithms perform well, while some others are significantly worse. Given its vintage and ad-hoc formulation backprojection works surprisingly well, supporting the validity of previous studies in lung EIT.

  14. Validation and testing of the VAM2D computer code

    International Nuclear Information System (INIS)

    Kool, J.B.; Wu, Y.S.

    1991-10-01

    This document describes two modeling studies conducted by HydroGeoLogic, Inc. for the US NRC under contract no. NRC-04089-090, entitled, ''Validation and Testing of the VAM2D Computer Code.'' VAM2D is a two-dimensional, variably saturated flow and transport code, with applications for performance assessment of nuclear waste disposal. The computer code itself is documented in a separate NUREG document (NUREG/CR-5352, 1989). The studies presented in this report involve application of the VAM2D code to two diverse subsurface modeling problems. The first one involves modeling of infiltration and redistribution of water and solutes in an initially dry, heterogeneous field soil. This application involves detailed modeling over a relatively short, 9-month time period. The second problem pertains to the application of VAM2D to the modeling of a waste disposal facility in a fractured clay, over much larger space and time scales and with particular emphasis on the applicability and reliability of using equivalent porous medium approach for simulating flow and transport in fractured geologic media. Reflecting the separate and distinct nature of the two problems studied, this report is organized in two separate parts. 61 refs., 31 figs., 9 tabs

  15. A proposed best practice model validation framework for banks

    Directory of Open Access Journals (Sweden)

    Pieter J. (Riaan de Jongh

    2017-06-01

    Full Text Available Background: With the increasing use of complex quantitative models in applications throughout the financial world, model risk has become a major concern. The credit crisis of 2008–2009 provoked added concern about the use of models in finance. Measuring and managing model risk has subsequently come under scrutiny from regulators, supervisors, banks and other financial institutions. Regulatory guidance indicates that meticulous monitoring of all phases of model development and implementation is required to mitigate this risk. Considerable resources must be mobilised for this purpose. The exercise must embrace model development, assembly, implementation, validation and effective governance. Setting: Model validation practices are generally patchy, disparate and sometimes contradictory, and although the Basel Accord and some regulatory authorities have attempted to establish guiding principles, no definite set of global standards exists. Aim: Assessing the available literature for the best validation practices. Methods: This comprehensive literature study provided a background to the complexities of effective model management and focussed on model validation as a component of model risk management. Results: We propose a coherent ‘best practice’ framework for model validation. Scorecard tools are also presented to evaluate if the proposed best practice model validation framework has been adequately assembled and implemented. Conclusion: The proposed best practice model validation framework is designed to assist firms in the construction of an effective, robust and fully compliant model validation programme and comprises three principal elements: model validation governance, policy and process.

  16. Synergy of the Developed 6D BIM Framework and Conception of the nD BIM Framework and nD BIM Process Ontology

    Science.gov (United States)

    O'Keeffe, Shawn Edward

    2013-01-01

    The author developed a unified nD framework and process ontology for Building Information Modeling (BIM). The research includes a framework developed for 6D BIM, nD BIM, and nD ontology that defines the domain and sub-domain constructs for future nD BIM dimensions. The nD ontology defines the relationships of kinds within any new proposed…

  17. Radiative heat transfer in 2D Dirac materials

    International Nuclear Information System (INIS)

    Rodriguez-López, Pablo; Tse, Wang-Kong; Dalvit, Diego A R

    2015-01-01

    We compute the radiative heat transfer between two sheets of 2D Dirac materials, including topological Chern insulators and graphene, within the framework of the local approximation for the optical response of these materials. In this approximation, which neglects spatial dispersion, we derive both numerically and analytically the short-distance asymptotic of the near-field heat transfer in these systems, and show that it scales as the inverse of the distance between the two sheets. Finally, we discuss the limitations to the validity of this scaling law imposed by spatial dispersion in 2D Dirac materials. (paper)

  18. Amine-controlled assembly of metal-sulfite architecture from 1D chains to 3D framework.

    Science.gov (United States)

    Austria, Cristina; Zhang, Jian; Valle, Henry; Zhang, Qichun; Chew, Emily; Nguyen, Dan-Tam; Gu, J Y; Feng, Pingyun; Bu, Xianhui

    2007-08-06

    Whereas open-framework materials have been made in a variety of chemical compositions, few are known in which 3-connected SO3(2)- anions serve as basic building units. Here, we report four new metal-sulfite polymeric structures, (ZnSO3)Py (1, py = pyridine), (ZnSO3)2(2,2'-bipy)H2O (2, 2,2'-bipy = 2,2'-bipyridine), (ZnSO3)2(TMDPy) (3, TMDPy = 4,4'-trimethylenedipyridine), and (MnSO3)2en (4, en = ethylenediamine) that have been synthesized hydrothermally and structurally characterized. In these compounds, low-dimensional 1D and 2D inorganic subunits are assembled into higher 2D or 3D covalent frameworks by organic ligands. In addition to the structure-directing effect of organic ligands, the flexible coordination chemistry of Zn2+ and SO3(2)- also contributes to the observed structural diversity. In compounds 1-3, Zn2+ sites alternate with trigonal pyramidal SO3(2)- anions to form three types of [ZnSO3]n chains, whereas in compound 4, a 2D-corrugated [MnSO3]n layer is present. Compound 1 features a rail-like chain with pendant pyridine rings. The pi-pi interaction between 2,2'-bipy ligands is found between adjacent chains in compound 2, resulting in 2D sheets that are further stacked through interlayer hydrogen bonds. Compound 3 exhibits a very interesting inorganic [(ZnSO3)2]n chain constructed from two chairlike subunits, and such chains are bridged by TMDPy ligands into a 2D sheet. In compound 4, side-by-side helical chains permeate through 2D-corrugated [MnSO3]n layers, which are pillared by neutral ethylenediamine molecules into a 3D framework that can be topologically represented as a (3,6)-connected net. The results presented here illustrate the rich structural chemistry of metal-sulfites and the potential of sulfite anions as a unique structural building block for the construction of novel open-framework materials, in particular, those containing polymeric inorganic subunits that may have interesting physical properties such as low-dimensional magnetism or

  19. A multimodal 3D framework for fire characteristics estimation

    Science.gov (United States)

    Toulouse, T.; Rossi, L.; Akhloufi, M. A.; Pieri, A.; Maldague, X.

    2018-02-01

    In the last decade we have witnessed an increasing interest in using computer vision and image processing in forest fire research. Image processing techniques have been successfully used in different fire analysis areas such as early detection, monitoring, modeling and fire front characteristics estimation. While the majority of the work deals with the use of 2D visible spectrum images, recent work has introduced the use of 3D vision in this field. This work proposes a new multimodal vision framework permitting the extraction of the three-dimensional geometrical characteristics of fires captured by multiple 3D vision systems. The 3D system is a multispectral stereo system operating in both the visible and near-infrared (NIR) spectral bands. The framework supports the use of multiple stereo pairs positioned so as to capture complementary views of the fire front during its propagation. Multimodal registration is conducted using the captured views in order to build a complete 3D model of the fire front. The registration process is achieved using multisensory fusion based on visual data (2D and NIR images), GPS positions and IMU inertial data. Experiments were conducted outdoors in order to show the performance of the proposed framework. The obtained results are promising and show the potential of using the proposed framework in operational scenarios for wildland fire research and as a decision management system in fighting.

  20. Power loss analysis of n-PASHA cells validated by 2D simulations

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, G.J.M.; Gutjahr, A.; Burgers, A.R.; Saynova, D.S.; Cesar, I.; Romijn, I.G.

    2013-10-15

    To reach >21% efficiency for the n-Pasha (passivated all sides H-pattern) cell of ECN, reliable power-loss analyses are essential. A power-loss analysis is presented that is based on experimental data but validated and completed by 2D simulations. The analysis is used to identify the key factors that will contribute most to achieving >21% efficiency.

  1. Validation of the entire 2D array Octavius by radiochromic films; Validacion del conjunto Octavius 2D array mediante peliculas radiocromicas

    Energy Technology Data Exchange (ETDEWEB)

    Iriondo Igerabide, U.; Former Forner, A.; Otal Palacin, A.; Martin Albina, M. L.; Lozares Cordero, S.; Maneru Camara, F.; Pellejero Pellejero, S.; Miquelez Alonso, S.; Soto Prados, P. M.; Rubio Arroniz, A.

    2011-07-01

    We have validated the 2D-array Octavius set for verification of IMRT plans complete, radiating with the same angles of incidence in the patient's actual plan. This has been taken as reference measurements with radiochromic films, since they are almost isotropic response, higher resolution and we already have experience with them.

  2. New coordination polymers from 1D chain, 2D layer to 3D framework constructed from 1,2-phenylenediacetic acid and 1,3-bis(4-pyridyl)propane flexible ligands

    Science.gov (United States)

    Xin, Ling-Yun; Liu, Guang-Zhen; Wang, Li-Ya

    2011-06-01

    The hydrothermal reactions of Cd, Zn, or Cu(II) acetate salts with H 2PHDA and BPP flexible ligands afford three new coordination polymers, including [Cd(PHDA)(BPP)(H 2O)] n(1), [Zn(PHDA)(BPP)] n(2), and [Cu 2(PHDA) 2(BPP)] n(3) (H 2PHDA=1,2-phenylenediacetic acid, BPP=1,3-bis(4-pyridyl)propane). The single-crystal X-ray diffractions reveal that all three complexes feature various metal carboxylate subunits extended further by the BPP ligands to form a diverse range of structures, displaying a remarked structural sensitivity to metal(II) cation. Complex 1 containing PHDA-bridged binuclear cadmium generates 1D double-stranded chain, complex 2 results in 2D→2D interpenetrated (4,4) grids, and complex 3 displays a 3D self-penetrated framework with 4 86 68 rob topology. In addition, fluorescent analyses show that both 1 and 2 exhibit intense blue-violet photoluminescence in the solid state.

  3. Adapforms: A framework for creating and validating adaptive forms

    DEFF Research Database (Denmark)

    Bohøj, Morten; Bouvin, Niels Olof; Gammelmark, Henrik

    2011-01-01

    AdapForms is a framework for adaptive forms, consisting of a form de nition language designating structure and constraints upon acceptable input, and a software architecture that continuously validates and adapts the form presented to the user. The validation is performed server-side, which enables...

  4. Morphable 3D-Mosaics: A Hybrid Framework for Photorealistic Walkthroughs of Large Natural Environments

    Directory of Open Access Journals (Sweden)

    Nikos Komodakis

    2008-01-01

    Full Text Available This paper presents a hybrid (geometry- & image-based framework suitable for providing photorealistic walkthroughs of large, complex outdoor scenes at interactive frame rates. To this end, based just on a sparse set of real stereoscopic views from the scene, a set of morphable 3D-mosaics is automatically constructed first, and then, during rendering, a continuous morphing between those 3D-mosaics that are nearby to the current viewpoint is taking place. The morphing is both photometric, as well as geometric, while we also ensure that it proceeds in a physically valid manner, thus remaining transparent to the user. The effectiveness of our framework has been demonstrated in the 3D visual reconstruction of the Samaria Gorge in Crete, which is one of the largest and most beautiful gorges in Europe.

  5. An R&D Management Framework for Eco-Technology

    Directory of Open Access Journals (Sweden)

    Kenji Sano

    2011-08-01

    Full Text Available Although research and development (R&D affects new value-added creation, including that related to environmental aspects, there is little literature dealing with the integration of R&D management and eco-value. Here, eco-value of technology is defined as the advantage of environmental competitiveness in the market. This paper proposes a framework of R&D management of eco-technology (RDMOET, consisting of: (1 future research for sustainability; (2 making an original eco-theme portfolio and roadmap; (3 gap analysis and implementation of new eco-themes; and (4 eco-value evaluation. (1 and (4 are new processes compared with conventional R&D management. Through practice at the Corporate R&D Center of Toshiba Corporation, the usefulness of the proposed framework is verified from the viewpoint of not only technological eco-innovation, but also that of organizational learning for environmental sustainability.

  6. Validation of digit-length ratio (2D:4D) assessments on the basis of DXA-derived hand scans

    International Nuclear Information System (INIS)

    Romann, Michael; Fuchslocher, Jörg

    2015-01-01

    The second-to-fourth digit-length ratio (2D:4D) may be a correlate of prenatal sex steroids, and it has been linked to sporting prowess. The aim of the study was to validate dual-energy X-ray-absorptiometry (DXA) as a technique to assess 2D:4D in soccer players under 15 years of age (U-15). Paired X-ray and DXA scans of the left hands of 63 male U-15 elite soccer players (age: 14.0 ± 0.3 years) were performed, and 2D:4D was then compared between the two techniques. The 2D:4D measurements were performed twice by two blinded raters. Intrarater and interrater reliability, as well as agreement between the X-ray and the DXA assessments, were tested. Intrarater reliabilities of both raters using X-ray with intraclass correlation coefficients (ICCs) of 0.97 and 0.90 were excellent. Using DXA, the ICCs were 0.90 and 0.91 thus also showing excellent reliability. Interrater reliabilities were excellent using both the X-ray (ICC of 0.94) and the DXA (ICC of 0.90), assessments respectively. Bland-Altman plots demonstrated that the 2D:4D ratios of the two raters did not differ significantly between the X-ray and the DXA assessments. The standard errors of estimate were 0.01 for both techniques. The 95% limits of agreement of ±0.018 (±2.0%) and ±0.023 (±2.6%), respectively, were within the acceptable tolerance of 5%, and showed very good agreement. DXA offered a replicable technique for assessing 2D:4D in youth soccer players. Therefore, the DXA technique seems to be an alternative method for evaluating 2D:4D in youth sports

  7. Construction concepts and validation of the 3D printed UST_2 modular stellarator

    Science.gov (United States)

    Queral, V.

    2015-03-01

    High accuracy, geometric complexity and thus high cost of stellarators tend to hinder the advance of stellarator research. Nowadays, new manufacturing methods might be developed for the production of small and middle-size stellarators. The methods should demonstrate advantages with respect common fabrication methods, like casting, cutting, forging and welding, for the construction of advanced highly convoluted modular stellarators. UST2 is a small modular three period quasi-isodynamic stellarator of major radius 0.26 m and plasma volume 10 litres being currently built to validate additive manufacturing (3D printing) for stellarator construction. The modular coils are wound in grooves defined on six 3D printed half period frames designed as light truss structures filled by a strong filler. A geometrically simple assembling configuration has been concocted for UST2 so as to try to lower the cost of the device while keeping the positioning accuracy of the different elements. The paper summarizes the construction and assembling concepts developed, the devised positioning methodology, the design of the coil frames and positioning elements and, an initial validation of the assembling of the components.

  8. Technical skills assessment toolbox: a review using the unitary framework of validity.

    Science.gov (United States)

    Ghaderi, Iman; Manji, Farouq; Park, Yoon Soo; Juul, Dorthea; Ott, Michael; Harris, Ilene; Farrell, Timothy M

    2015-02-01

    The purpose of this study was to create a technical skills assessment toolbox for 35 basic and advanced skills/procedures that comprise the American College of Surgeons (ACS)/Association of Program Directors in Surgery (APDS) surgical skills curriculum and to provide a critical appraisal of the included tools, using contemporary framework of validity. Competency-based training has become the predominant model in surgical education and assessment of performance is an essential component. Assessment methods must produce valid results to accurately determine the level of competency. A search was performed, using PubMed and Google Scholar, to identify tools that have been developed for assessment of the targeted technical skills. A total of 23 assessment tools for the 35 ACS/APDS skills modules were identified. Some tools, such as Operative Performance Rating System (OSATS) and Objective Structured Assessment of Technical Skill (OPRS), have been tested for more than 1 procedure. Therefore, 30 modules had at least 1 assessment tool, with some common surgical procedures being addressed by several tools. Five modules had none. Only 3 studies used Messick's framework to design their validity studies. The remaining studies used an outdated framework on the basis of "types of validity." When analyzed using the contemporary framework, few of these studies demonstrated validity for content, internal structure, and relationship to other variables. This study provides an assessment toolbox for common surgical skills/procedures. Our review shows that few authors have used the contemporary unitary concept of validity for development of their assessment tools. As we progress toward competency-based training, future studies should provide evidence for various sources of validity using the contemporary framework.

  9. A contemporary approach to validity arguments: a practical guide to Kane's framework.

    Science.gov (United States)

    Cook, David A; Brydges, Ryan; Ginsburg, Shiphra; Hatala, Rose

    2015-06-01

    Assessment is central to medical education and the validation of assessments is vital to their use. Earlier validity frameworks suffer from a multiplicity of types of validity or failure to prioritise among sources of validity evidence. Kane's framework addresses both concerns by emphasising key inferences as the assessment progresses from a single observation to a final decision. Evidence evaluating these inferences is planned and presented as a validity argument. We aim to offer a practical introduction to the key concepts of Kane's framework that educators will find accessible and applicable to a wide range of assessment tools and activities. All assessments are ultimately intended to facilitate a defensible decision about the person being assessed. Validation is the process of collecting and interpreting evidence to support that decision. Rigorous validation involves articulating the claims and assumptions associated with the proposed decision (the interpretation/use argument), empirically testing these assumptions, and organising evidence into a coherent validity argument. Kane identifies four inferences in the validity argument: Scoring (translating an observation into one or more scores); Generalisation (using the score[s] as a reflection of performance in a test setting); Extrapolation (using the score[s] as a reflection of real-world performance), and Implications (applying the score[s] to inform a decision or action). Evidence should be collected to support each of these inferences and should focus on the most questionable assumptions in the chain of inference. Key assumptions (and needed evidence) vary depending on the assessment's intended use or associated decision. Kane's framework applies to quantitative and qualitative assessments, and to individual tests and programmes of assessment. Validation focuses on evaluating the key claims, assumptions and inferences that link assessment scores with their intended interpretations and uses. The Implications

  10. Validating a Conceptual Framework for the Core Concept of "Cell-Cell Communication"

    Science.gov (United States)

    Michael, Joel; Martinkova, Patricia; McFarland, Jenny; Wright, Ann; Cliff, William; Modell, Harold; Wenderoth, Mary Pat

    2017-01-01

    We have created and validated a conceptual framework for the core physiology concept of "cell-cell communication." The conceptual framework is composed of 51 items arranged in a hierarchy that is, in some instances, four levels deep. We have validated it with input from faculty who teach at a wide variety of institutional types. All…

  11. A Game Theoretic Framework for Green HetNets Using D2D Traffic Offload and Renewable Energy Powered Base Stations

    KAUST Repository

    Yaacoub, Elias

    2015-08-26

    This chapter investigates the interplay between cooperative device-to-device (D2D) communications and green communications in LTE heterogeneous networks (HetNets). Two game theoretic concepts are studied and analyzed in order to perform dynamic HetNet base station (BS) on/off switching. The first approach is a coalition-based method whereas the second is based on the Nash bargaining solution. Afterwards, a method for coupling the BS on/off switching approach with D2D collaborative communications is presented and shown to lead to increased energy efficiency. The savings are additionally increased when a portion of the small cell BSs in a HetNet are powered by renewable energy sources. Different utility functions, modeling the game theoretic framework governing the energy consumption balance between the cellular network and the mobile terminals (MTs), are proposed and compared, and their impact on MT quality of service (QoS) is analyzed.

  12. A Game Theoretic Framework for Green HetNets Using D2D Traffic Offload and Renewable Energy Powered Base Stations

    KAUST Repository

    Yaacoub, Elias; Ghazzai, Hakim; Alouini, Mohamed-Slim

    2015-01-01

    This chapter investigates the interplay between cooperative device-to-device (D2D) communications and green communications in LTE heterogeneous networks (HetNets). Two game theoretic concepts are studied and analyzed in order to perform dynamic HetNet base station (BS) on/off switching. The first approach is a coalition-based method whereas the second is based on the Nash bargaining solution. Afterwards, a method for coupling the BS on/off switching approach with D2D collaborative communications is presented and shown to lead to increased energy efficiency. The savings are additionally increased when a portion of the small cell BSs in a HetNet are powered by renewable energy sources. Different utility functions, modeling the game theoretic framework governing the energy consumption balance between the cellular network and the mobile terminals (MTs), are proposed and compared, and their impact on MT quality of service (QoS) is analyzed.

  13. An R&D Management Framework for Eco-Technology

    OpenAIRE

    Hideki Kobayashi; Masahiro Kato; Yukishige Maezawa; Kenji Sano

    2011-01-01

    Although research and development (R&D) affects new value-added creation, including that related to environmental aspects, there is little literature dealing with the integration of R&D management and eco-value. Here, eco-value of technology is defined as the advantage of environmental competitiveness in the market. This paper proposes a framework of R&D management of eco-technology (RDMOET), consisting of: (1) future research for sustainability; (2) making an original eco-theme p...

  14. K2Ln2As2Se9 (Ln = Sm, Gd): the first quaternary rare-earth selenoarsenate compounds with a 3D framework containing chairlike As2Se4 units.

    Science.gov (United States)

    Wu, Yuandong; Bensch, Wolfgang

    2009-04-06

    The new compounds K(2)Ln(2)As(2)Se(9) (Ln = Sm, Gd) were obtained by applying the reactive flux method. The structure consists of a three-dimensional (3D) [Ln(2)As(2)Se(9)](2-) framework with K(+) ion-filling tunnels running along the b axis. The two unique Ln(3+) cations are coordinated by two Se(2)(2-) dumbbells, two AsSe(3)(3-) pyramids, and one chairlike As(2)Se(4)(2-) unit in a bicapped trigonal-prismatic geometry. The Ln(3+)-centered trigonal prisms share triangular faces with neighboring prisms, forming one-dimensional chains along the b axis. These chains are linked to each other to form layers by sharing Se(2-) anions on the capped sites of the trigonal prisms. The As(2)Se(4) units connect these layers to form the 3D framework.

  15. Construction concepts and validation of the 3D printed UST-2 modular stellarator

    International Nuclear Information System (INIS)

    Queral, V

    2015-01-01

    High accuracy, geometric complexity and thus high cost of stellarators tend to hinder the advance of stellarator research. Nowadays, new manufacturing methods might be developed for the production of small and middle-size stellarators. The methods should demonstrate advantages with respect common fabrication methods, like casting, cutting, forging and welding, for the construction of advanced highly convoluted modular stellarators. UST-2 is a small modular three period quasi-isodynamic stellarator of major radius 0.26 m and plasma volume 10 litres being currently built to validate additive manufacturing (3D printing) for stellarator construction. The modular coils are wound in grooves defined on six 3D printed half period frames designed as light truss structures filled by a strong filler. A geometrically simple assembling configuration has been concocted for UST-2 so as to try to lower the cost of the device while keeping the positioning accuracy of the different elements. The paper summarizes the construction and assembling concepts developed, the devised positioning methodology, the design of the coil frames and positioning elements and, an initial validation of the assembling of the components. (paper)

  16. Validity of computational hemodynamics in human arteries based on 3D time-of-flight MR angiography and 2D electrocardiogram gated phase contrast images

    Science.gov (United States)

    Yu, Huidan (Whitney); Chen, Xi; Chen, Rou; Wang, Zhiqiang; Lin, Chen; Kralik, Stephen; Zhao, Ye

    2015-11-01

    In this work, we demonstrate the validity of 4-D patient-specific computational hemodynamics (PSCH) based on 3-D time-of-flight (TOF) MR angiography (MRA) and 2-D electrocardiogram (ECG) gated phase contrast (PC) images. The mesoscale lattice Boltzmann method (LBM) is employed to segment morphological arterial geometry from TOF MRA, to extract velocity profiles from ECG PC images, and to simulate fluid dynamics on a unified GPU accelerated computational platform. Two healthy volunteers are recruited to participate in the study. For each volunteer, a 3-D high resolution TOF MRA image and 10 2-D ECG gated PC images are acquired to provide the morphological geometry and the time-varying flow velocity profiles for necessary inputs of the PSCH. Validation results will be presented through comparisons of LBM vs. 4D Flow Software for flow rates and LBM simulation vs. MRA measurement for blood flow velocity maps. Indiana University Health (IUH) Values Fund.

  17. 3D strata objectsregistration for Malaysia within the LADM framework

    NARCIS (Netherlands)

    Zulkifli, N.A.; Abdul Rahman, A.; Van Oosterom, P.J.M.

    2011-01-01

    This paper discusses 3D objects registration and modelling for cadastral objects within the Land Administration Domain Model (LADM) framework. A conceptual model as well as the associated technical model for the 2D and 3D objects have been proposed and developed for Malaysia. For both private and

  18. Rapid and Efficient Redox Processes within 2D Covalent Organic Framework Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    DeBlase, Catherine R. [Department of Chemistry and Chemical Biology, Cornell University, Baker Laboratory, Ithaca, New York 14853-1301, United States; Hernández-Burgos, Kenneth [Department of Chemistry and Chemical Biology, Cornell University, Baker Laboratory, Ithaca, New York 14853-1301, United States; Silberstein, Katharine E. [Department of Chemistry and Chemical Biology, Cornell University, Baker Laboratory, Ithaca, New York 14853-1301, United States; Rodríguez-Calero, Gabriel G. [Department of Chemistry and Chemical Biology, Cornell University, Baker Laboratory, Ithaca, New York 14853-1301, United States; Bisbey, Ryan P. [Department of Chemistry and Chemical Biology, Cornell University, Baker Laboratory, Ithaca, New York 14853-1301, United States; Abruña, Héctor D. [Department of Chemistry and Chemical Biology, Cornell University, Baker Laboratory, Ithaca, New York 14853-1301, United States; Dichtel, William R. [Department of Chemistry and Chemical Biology, Cornell University, Baker Laboratory, Ithaca, New York 14853-1301, United States

    2015-02-17

    Two-dimensional covalent organic frameworks (2D COFs) are ideally suited for organizing redox-active subunits into periodic, permanently porous polymer networks of interest for pseudocapacitive energy storage. Here we describe a method for synthesizing crystalline, oriented thin films of a redox-active 2D COF on Au working electrodes. The thickness of the COF film was controlled by varying the initial monomer concentration. A large percentage (80–99%) of the anthraquinone groups are electrochemically accessible in films thinner than 200 nm, an order of magnitude improvement over the same COF prepared as a randomly oriented microcrystalline powder. As a result, electrodes functionalized with oriented COF films exhibit a 400% increase in capacitance scaled to electrode area as compared to those functionalized with the randomly oriented COF powder. These results demonstrate the promise of redox-active COFs for electrical energy storage and highlight the importance of controlling morphology for optimal performance.

  19. Rapid and Efficient Redox Processes within 2D Covalent Organic Framework Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    DeBlase, Catherine R.; Hernández-Burgos, Kenneth; Silberstein, Katharine E.; Rodríguez-Calero, Gabriel G.; Bisbey, Ryan P.; Abruña, Héctor D.; Dichtel, William R.

    2015-03-24

    Two-dimensional covalent organic frameworks (2D COFs) are ideally suited for organizing redox-active subunits into periodic, permanently porous polymer networks of interest for pseudocapacitive energy storage. Here we describe a method for synthesizing crystalline, oriented thin films of a redox-active 2D COF on Au working electrodes. The thickness of the COF film was controlled by varying the initial monomer concentration. A large percentage (80–99%) of the anthraquinone groups are electrochemically accessible in films thinner than 200 nm, an order of magnitude improvement over the same COF prepared as a randomly oriented microcrystalline powder. As a result, electrodes functionalized with oriented COF films exhibit a 400% increase in capacitance scaled to electrode area as compared to those functionalized with the randomly oriented COF powder. These results demonstrate the promise of redox-active COFs for electrical energy storage and highlight the importance of controlling morphology for optimal performance.

  20. Preliminary Validation and Verification of TURBO{sub D}ESIGN for S-CO{sub 2} Axial Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Je Kyoung; Lee, Jeong Ik; Ahn, Yoon Han; Kim, Seong Gu [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Yoon, Ho Joon; Addad, Yacine [Khalifa University of Science, Technology and Research, Abu Dhabi (United Arab Emirates)

    2012-05-15

    To use the advantages of Supercritical CO{sub 2}(S-CO{sub 2}) Brayton cycle for nuclear power plant, KAIST-Khalifa University joint research team has been focusing on S-CO{sub 2} turbomachinery development. TURBO{sub D}ESIGN code is one of the products of our researches to design a turbomachinery. The major feature of TURBO{sub D}ESIGN is that the formulation is based on the real gas and none of the ideal gas assumption was applied to the code. Thus, TURBO{sub D}ESIGN has high flexibility regarding the type of gases. In this paper, preliminary code validation and verification of TURBO{sub D}ESIGN will be discussed for axial type compressor design

  1. Validation and uncertainty analysis of a pre-treatment 2D dose prediction model

    Science.gov (United States)

    Baeza, Jose A.; Wolfs, Cecile J. A.; Nijsten, Sebastiaan M. J. J. G.; Verhaegen, Frank

    2018-02-01

    Independent verification of complex treatment delivery with megavolt photon beam radiotherapy (RT) has been effectively used to detect and prevent errors. This work presents the validation and uncertainty analysis of a model that predicts 2D portal dose images (PDIs) without a patient or phantom in the beam. The prediction model is based on an exponential point dose model with separable primary and secondary photon fluence components. The model includes a scatter kernel, off-axis ratio map, transmission values and penumbra kernels for beam-delimiting components. These parameters were derived through a model fitting procedure supplied with point dose and dose profile measurements of radiation fields. The model was validated against a treatment planning system (TPS; Eclipse) and radiochromic film measurements for complex clinical scenarios, including volumetric modulated arc therapy (VMAT). Confidence limits on fitted model parameters were calculated based on simulated measurements. A sensitivity analysis was performed to evaluate the effect of the parameter uncertainties on the model output. For the maximum uncertainty, the maximum deviating measurement sets were propagated through the fitting procedure and the model. The overall uncertainty was assessed using all simulated measurements. The validation of the prediction model against the TPS and the film showed a good agreement, with on average 90.8% and 90.5% of pixels passing a (2%,2 mm) global gamma analysis respectively, with a low dose threshold of 10%. The maximum and overall uncertainty of the model is dependent on the type of clinical plan used as input. The results can be used to study the robustness of the model. A model for predicting accurate 2D pre-treatment PDIs in complex RT scenarios can be used clinically and its uncertainties can be taken into account.

  2. On QCD Q2-evolution of deuteron structure function F2D(xD, Q2) for xD>1

    International Nuclear Information System (INIS)

    Sidorov, A.V.; Tokarev, M.V.

    1995-01-01

    The deep-inelastic deuteron structure function (SF) F 2 D (x D ,Q 2 ) in the covariant approach in light-cone variables is considered. The x D and Q 2 -dependences of SF are calculated. The QCD analysis of generated data both for non-cumulative x D D >1 ranges was performed. It was shown that Q 2 -evolution of SF is valid for ranges 0.275 D D D -dependence of SF for the ranges is essentially different. 23 refs., 2 figs., 1 tab

  3. Non-local electron transport validation using 2D DRACO simulations

    Science.gov (United States)

    Cao, Duc; Chenhall, Jeff; Moll, Eli; Prochaska, Alex; Moses, Gregory; Delettrez, Jacques; Collins, Tim

    2012-10-01

    Comparison of 2D DRACO simulations, using a modified versionfootnotetextprivate communications with M. Marinak and G. Zimmerman, LLNL. of the Schurtz, Nicolai and Busquet (SNB) algorithmfootnotetextSchurtz, Nicolai and Busquet, ``A nonlocal electron conduction model for multidimensional radiation hydrodynamics codes,'' Phys. Plasmas 7, 4238(2000). for non-local electron transport, with direct drive shock timing experimentsfootnotetextT. Boehly, et. al., ``Multiple spherically converging shock waves in liquid deuterium,'' Phys. Plasmas 18, 092706(2011). and with the Goncharov non-local modelfootnotetextV. Goncharov, et. al., ``Early stage of implosion in inertial confinement fusion: Shock timing and perturbation evolution,'' Phys. Plasmas 13, 012702(2006). in 1D LILAC will be presented. Addition of an improved SNB non-local electron transport algorithm in DRACO allows direct drive simulations with no need for an electron conduction flux limiter. Validation with shock timing experiments that mimic the laser pulse profile of direct drive ignition targets gives a higher confidence level in the predictive capability of the DRACO code. This research was supported by the University of Rochester Laboratory for Laser Energetics.

  4. Development of a registration framework to validate MRI with histology for prostate focal therapy.

    Science.gov (United States)

    Reynolds, H M; Williams, S; Zhang, A; Chakravorty, R; Rawlinson, D; Ong, C S; Esteva, M; Mitchell, C; Parameswaran, B; Finnegan, M; Liney, G; Haworth, A

    2015-12-01

    Focal therapy has been proposed as an alternative method to whole-gland treatment for prostate cancer when aiming to reduce treatment side effects. The authors recently validated a radiobiological model which takes into account tumor location and tumor characteristics including tumor cell density, Gleason score, and hypoxia in order to plan optimal dose distributions for focal therapy. The authors propose that this model can be informed using multiparametric MRI (mpMRI) and in this study present a registration framework developed to map prostate mpMRI and histology data, where histology will provide the "ground truth" data regarding tumor location and biology. The authors aim to apply this framework to a growing database to develop a prostate biological atlas which will enable MRI based planning for prostate focal therapy treatment. Six patients scheduled for routine radical prostatectomy were used in this proof-of-concept study. Each patient underwent mpMRI scanning prior to surgery, after which the excised prostate specimen was formalin fixed and mounted in agarose gel in a custom designed sectioning box. T2-weighted MRI of the specimen in the sectioning box was acquired, after which 5 mm sections of the prostate were cut and histology sections were microtomed. A number of image processing and registration steps were used to register histology images with ex vivo MRI and deformable image registration (DIR) was applied to 3D T2w images to align the in vivo and ex vivo MRI data. Dice coefficient metrics and corresponding feature points from two independent annotators were selected in order to assess the DIR accuracy. Images from all six patients were registered, providing histology and in vivo MRI in the ex vivo MRI frame of reference for each patient. Results demonstrated that their DIR methodology to register in vivo and ex vivo 3D T2w MRI improved accuracy in comparison with an initial manual alignment for prostates containing features which were readily visible

  5. Automatic Depth Extraction from 2D Images Using a Cluster-Based Learning Framework.

    Science.gov (United States)

    Herrera, Jose L; Del-Blanco, Carlos R; Garcia, Narciso

    2018-07-01

    There has been a significant increase in the availability of 3D players and displays in the last years. Nonetheless, the amount of 3D content has not experimented an increment of such magnitude. To alleviate this problem, many algorithms for converting images and videos from 2D to 3D have been proposed. Here, we present an automatic learning-based 2D-3D image conversion approach, based on the key hypothesis that color images with similar structure likely present a similar depth structure. The presented algorithm estimates the depth of a color query image using the prior knowledge provided by a repository of color + depth images. The algorithm clusters this database attending to their structural similarity, and then creates a representative of each color-depth image cluster that will be used as prior depth map. The selection of the appropriate prior depth map corresponding to one given color query image is accomplished by comparing the structural similarity in the color domain between the query image and the database. The comparison is based on a K-Nearest Neighbor framework that uses a learning procedure to build an adaptive combination of image feature descriptors. The best correspondences determine the cluster, and in turn the associated prior depth map. Finally, this prior estimation is enhanced through a segmentation-guided filtering that obtains the final depth map estimation. This approach has been tested using two publicly available databases, and compared with several state-of-the-art algorithms in order to prove its efficiency.

  6. Solvothermal Synthesis, Crystal Structure, and Magnetic Properties of [Co3(SDA)3(DMF)2]: 2-D Layered Metal-organic Framework Derived from 4,4'-Stilbenedicarboxylic Acid (H2SDA)

    International Nuclear Information System (INIS)

    Park, Gyung Se; Kim, Hyun Uk; Kim, Ki Moon; Lee, Gang Ho; Park, Sang Kyu

    2006-01-01

    A new 2-D coordination polymer has been synthesized and characterized by using a novel 4,4'-stilbene dicarboxylic acid and Co(ClO 4 ) 2 ·6H 2 O. The title complex has an unique Co 3 pin-wheel cluster in which central Co has octahedral geometry and two surrounding Co have tetrahedral geometry. The Co 3 pin-wheel clusters, the building unit, are linked through carboxylate oxygens to generate a 2-D layered coordination polymer in ABCABC packing mode. Variable-temperature magnetic susceptibility data of the title compound confirms the high spin splitting of Co with S=3/2. Syntheses of MOF by using SDA and other transition metal ions, Zn, Cd, and Mn, are on progress in this lab. Metal-organic frameworks (MOF) have attracted much more attention in the past decade owing to their various intriguing framework topologies and potential applications as functional materials in gas storage, separation, and catalysis. Because high framework stability is fundamental and essential property for many practical applications, multi-dentate linkers such as carboxylates have been extensively investigated for the formation of more rigid frameworks due to their ability to aggregate metal ions into M-O-C clusters called secondary building units (SBUs) rather than N-bound organic linkers such as 4,4-bipyridine (bipy)

  7. 3D structure tensor analysis of light microscopy data for validating diffusion MRI.

    Science.gov (United States)

    Khan, Ahmad Raza; Cornea, Anda; Leigland, Lindsey A; Kohama, Steven G; Jespersen, Sune Nørhøj; Kroenke, Christopher D

    2015-05-01

    Diffusion magnetic resonance imaging (d-MRI) is a powerful non-invasive and non-destructive technique for characterizing brain tissue on the microscopic scale. However, the lack of validation of d-MRI by independent experimental means poses an obstacle to accurate interpretation of data acquired using this method. Recently, structure tensor analysis has been applied to light microscopy images, and this technique holds promise to be a powerful validation strategy for d-MRI. Advantages of this approach include its similarity to d-MRI in terms of averaging the effects of a large number of cellular structures, and its simplicity, which enables it to be implemented in a high-throughput manner. However, a drawback of previous implementations of this technique arises from it being restricted to 2D. As a result, structure tensor analyses have been limited to tissue sectioned in a direction orthogonal to the direction of interest. Here we describe the analytical framework for extending structure tensor analysis to 3D, and utilize the results to analyze serial image "stacks" acquired with confocal microscopy of rhesus macaque hippocampal tissue. Implementation of 3D structure tensor procedures requires removal of sources of anisotropy introduced in tissue preparation and confocal imaging. This is accomplished with image processing steps to mitigate the effects of anisotropic tissue shrinkage, and the effects of anisotropy in the point spread function (PSF). In order to address the latter confound, we describe procedures for measuring the dependence of PSF anisotropy on distance from the microscope objective within tissue. Prior to microscopy, ex vivo d-MRI measurements performed on the hippocampal tissue revealed three regions of tissue with mutually orthogonal directions of least restricted diffusion that correspond to CA1, alveus and inferior longitudinal fasciculus. We demonstrate the ability of 3D structure tensor analysis to identify structure tensor orientations that

  8. Validation of the theoretical domains framework for use in behaviour change and implementation research

    OpenAIRE

    Cane, James E.; O'Connor, Denise; Michie, Susan

    2012-01-01

    Abstract Background An integrative theoretical framework, developed for cross-disciplinary implementation and other behaviour change research, has been applied across a wide range of clinical situations. This study tests the validity of this framework. Methods Validity was investigated by behavioural experts sorting 112 unique theoretical constructs using closed and open sort tasks. The extent of replication was tested by Discriminant Content Validation and Fuzzy Cluster Analysis. Results The...

  9. Hybridized Plasmons in 2D Nanoslits: From Graphene to Anisotropic 2D Materials

    DEFF Research Database (Denmark)

    Gonçalves, P. A. D.; Xiao, Sanshui; Peres, N. M. R.

    2017-01-01

    of arbitrary width, and remains valid irrespective of the 2D conductive material (e.g., doped graphene, 2D transition metal dichalcogenides, or phosphorene). We derive the dispersion relation of the hybrid modes of a 2D nanoslit along with the corresponding induced potential and electric field distributions...

  10. A novel 3D framework indium phosphite-oxalate based on a pcu-type topology

    International Nuclear Information System (INIS)

    Zuo, Mengmeng; Zhou, Mingdong; Hu, Dianwen; Gao, Fan; Dong, Sijie; Huang, Liangliang

    2016-01-01

    A new inorganic–organic hybrid indium phosphite-oxalate, formulated as H[In 5 (HPO 3 ) 6 (H 2 PO 3 ) 2 (C 2 O 4 ) 2 ]·(C 4 N 2 H 11 ) 2 ·H 2 O 1 has been hydrothermally synthesized in the presence of piperazine acting as a structure directing agent (SDA). The single crystal X-ray diffraction reveals that compound 1 shows three-dimensional open-framework with intersecting 12-ring channels along the [010] and [001] directions, which is constructed from strictly alternating double 6-ring units (D6Rs), [C 2 O 4 ] 2− groups and [H 2 PO 3 ] − pseudo-pyramids. It is noted that the classical D6R SBU is firstly reported in main metal phosphite/phosphite-oxalate. By regarding D6R as the 6-connected nodes, the inorganic–organic hybrid framework is based on a pcu-type topology. The as-synthesized product was characterized by single-crystal X-ray diffraction, powder X-ray diffraction, IR spectroscopy, thermogravimetric analysis (TGA), ICP-AES and elemental analyses. - Graphical abstract: A 3D open-framework indium phosphite-oxalate has been synthesized under hydrothermal conditions. A classical SBU, D6R, is present in the structure. By regarding D6R as the 6-connected nodes, the inorganic–organic hybrid framework is based on a pcu-type topology. - Highlights: • A new indium phosphite-oxalate based on a pcu-type topology has been synthesized. • A classical SBU, D6R, is present in the structure. • The classical SBU is firstly reported in main metal phosphite/phosphite-oxalate.

  11. Clinical feasibility and validation of 3D principal strain analysis from cine MRI: comparison to 2D strain by MRI and 3D speckle tracking echocardiography.

    Science.gov (United States)

    Satriano, Alessandro; Heydari, Bobak; Narous, Mariam; Exner, Derek V; Mikami, Yoko; Attwood, Monica M; Tyberg, John V; Lydell, Carmen P; Howarth, Andrew G; Fine, Nowell M; White, James A

    2017-12-01

    Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37-80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83-0.97 and 0.83-0.98, respectively-p analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.

  12. 3-D silver(I)-lanthanide(III) heterometallic-organic frameworks constructed from 2,2'-bipyridine-3,3'-dicarboxylic acid: synthesis, structure, photoluminescence, and their remarkable thermostability.

    Science.gov (United States)

    Zhou, Yunshan; Li, Xiaomin; Zhang, Lijuan; Guo, Yan; Shi, Zonghai

    2014-04-07

    A new family of silver(I)-lanthanide(III) heterometallic-organic frameworks having the formula [AgLn(bpdc)2] (Ln = Eu (1), Tb (2), Sm (3), Dy (4), Y (5), Yb (6), Er (7), Ho (8); H2bpdc = 2,2'-bipyridine-3,3'-dicarboxylic acid), each of which crystallizes in the monoclinic space group C2/c with Z = 4, has been hydrothermally synthesized. The compounds were characterized by means of IR, elemental analysis, thermogravimetric-differential thermal analysis, and powder X-ray diffraction (XRD), wherein compounds 1, 2, and 4-8 were structurally characterized. The powder XRD and single-crystal structures of the title compounds indicate that all the compounds are isostructural and feature a three-dimensional (3-D) open framework. In the structures of the compounds, bpdc(2-) ligands link Ln(3+) through their carboxylic groups, resulting in the formation of a one-dimensional {Ln(bpdc)2}n infinite chain along the c direction. The adjacent chains are then connected to each other through the coordination interaction between Ag(+) and the pyridyl N atoms of bpdc(2-) ligands from the chains, resulting in a 3-D (2,4,6)-connected open framework with (4(11)·6(4))(4(3)·8(2)·10)(8)2 topology. The compounds show remarkable good thermally stability up to 370 °C because neither aquo ligands nor lattice water molecules exist in the composition of the compounds. The photoluminescent properties of compounds 1 and 2 were studied in detail. The energy level of the triplet states of the ligand H2bpdc 21,505 cm(-1) (465 nm) was determined based on the 77 K emission spectrum of the compound [Gd2(bpdc)3(phen)2(H2O)2]·6H2O 9. The (5)D0 and (5)D4 emission lifetimes (1.58 and 1.76 ms) and the overall quantum yields (21% and 22%) were determined for the compounds 1 and 2, respectively.

  13. Validation of the theoretical domains framework for use in behaviour change and implementation research.

    Science.gov (United States)

    Cane, James; O'Connor, Denise; Michie, Susan

    2012-04-24

    An integrative theoretical framework, developed for cross-disciplinary implementation and other behaviour change research, has been applied across a wide range of clinical situations. This study tests the validity of this framework. Validity was investigated by behavioural experts sorting 112 unique theoretical constructs using closed and open sort tasks. The extent of replication was tested by Discriminant Content Validation and Fuzzy Cluster Analysis. There was good support for a refinement of the framework comprising 14 domains of theoretical constructs (average silhouette value 0.29): 'Knowledge', 'Skills', 'Social/Professional Role and Identity', 'Beliefs about Capabilities', 'Optimism', 'Beliefs about Consequences', 'Reinforcement', 'Intentions', 'Goals', 'Memory, Attention and Decision Processes', 'Environmental Context and Resources', 'Social Influences', 'Emotions', and 'Behavioural Regulation'. The refined Theoretical Domains Framework has a strengthened empirical base and provides a method for theoretically assessing implementation problems, as well as professional and other health-related behaviours as a basis for intervention development.

  14. From 3 d duality to 2 d duality

    Science.gov (United States)

    Aharony, Ofer; Razamat, Shlomo S.; Willett, Brian

    2017-11-01

    In this paper we discuss 3 d N = 2 supersymmetric gauge theories and their IR dualities when they are compactified on a circle of radius r, and when we take the 2 d limit in which r → 0. The 2 d limit depends on how the mass parameters are scaled as r → 0, and often vacua become infinitely distant in the 2 d limit, leading to a direct sum of different 2 d theories. For generic mass parameters, when we take the same limit on both sides of a duality, we obtain 2 d dualities (between gauge theories and/or Landau-Ginzburg theories) that pass all the usual tests. However, when there are non-compact branches the discussion is subtle because the metric on the moduli space, which is not controlled by supersymmetry, plays an important role in the low-energy dynamics after compactification. Generally speaking, for IR dualities of gauge theories, we conjecture that dualities involving non-compact Higgs branches survive. On the other hand when there is a non-compact Coulomb branch on at least one side of the duality, the duality fails already when the 3 d theories are compactified on a circle. Using the valid reductions we reproduce many known 2 d IR dualities, giving further evidence for their validity, and we also find new 2 d dualities.

  15. Impact of a five-dimensional framework on R&D productivity at AstraZeneca.

    Science.gov (United States)

    Morgan, Paul; Brown, Dean G; Lennard, Simon; Anderton, Mark J; Barrett, J Carl; Eriksson, Ulf; Fidock, Mark; Hamrén, Bengt; Johnson, Anthony; March, Ruth E; Matcham, James; Mettetal, Jerome; Nicholls, David J; Platz, Stefan; Rees, Steve; Snowden, Michael A; Pangalos, Menelas N

    2018-03-01

    In 2011, AstraZeneca embarked on a major revision of its research and development (R&D) strategy with the aim of improving R&D productivity, which was below industry averages in 2005-2010. A cornerstone of the revised strategy was to focus decision-making on five technical determinants (the right target, right tissue, right safety, right patient and right commercial potential). In this article, we describe the progress made using this '5R framework' in the hope that our experience could be useful to other companies tackling R&D productivity issues. We focus on the evolution of our approach to target validation, hit and lead optimization, pharmacokinetic/pharmacodynamic modelling and drug safety testing, which have helped improve the quality of candidate drug nomination, as well as the development of the right culture, where 'truth seeking' is encouraged by more rigorous and quantitative decision-making. We also discuss where the approach has failed and the lessons learned. Overall, the continued evolution and application of the 5R framework are beginning to have an impact, with success rates from candidate drug nomination to phase III completion improving from 4% in 2005-2010 to 19% in 2012-2016.

  16. Fabrications of some kinds of 2-D frameworks consisting of nanosized polyoxomolybdate anion [Mo36O112(H2O)16]8- via condensation processes

    International Nuclear Information System (INIS)

    Eda, Kazuo; Iriki, Yuichi; Kawamura, Kenjiro; Ikuki, Takeshi; Hayashi, Masahiko

    2007-01-01

    We succeeded to prepare novel [Mo 36 O 112 (H 2 O) 16 ] 8- ({Mo 36 }) compounds by using 1,3-diamino-2-propanol (βOHC 3 -DA) and 1,3,5-tris(aminomethyl)benzene (MES-TA)+1,3-diaminopropane (C 3 -DA) as linkers, and determined their crystal structures. We have confirmed they have unique two-dimensional (2-D) molybdenum oxide frameworks, which are formed by condensation of {Mo 36 }s. Side-staggered arrays of {Mo 36 }s, connected in lying position by eight bridges per a {Mo 36 }, are formed in the compound with βOHC 3 -DA, while herringbone arrays of {Mo 36 }s, connected in standing position by four bridges per a {Mo 36 }, are built in the compound with MES-TA+C 3 -DA. The latter compound exhibited non-stoichiometric property, and its composition and cell parameters varied depending on the relative concentration of MES-TA in the mother solution. - Graphical abstract: The image shows a variety of 2-D molybdenum oxide frameworks consisting of nanosized polyoxometalate anion [Mo 36 O 112 (H 2 O) 16 ] 8- ({Mo 36 }), obtained by our fabrication techniques. The variations are expected to provide diversity in physical properties of the frameworks

  17. A qualitative examination of the content validity of the EQ-5D-5L in patients with type 2 diabetes.

    Science.gov (United States)

    Matza, Louis S; Boye, Kristina S; Stewart, Katie D; Curtis, Bradley H; Reaney, Matthew; Landrian, Amanda S

    2015-12-01

    The EQ-5D is frequently used to derive utilities for patients with type 2 diabetes (T2D). Despite widely available quantitative psychometric data on the EQ-5D, little is known about content validity in this population. Thus, the purpose of this qualitative study was to examine content validity of the EQ-5D in patients with T2D. Patients with T2D in the UK completed concept elicitation interviews, followed by administration of the EQ-5D-5L and cognitive interviewing focused on the instrument's relevance, clarity, and comprehensiveness. A total of 25 participants completed interviews (52.0 % male; mean age = 53.5 years). Approximately half (52 %) reported that the EQ-5D-5L was relevant to their experience with T2D. When asked if each individual item was relevant to their experience with T2D, responses varied widely (24.0 % said the self-care item was relevant; 68.0 % said the anxiety/depression item was relevant). Participants frequently said items were not relevant to themselves, but could be relevant to patients with more severe diabetes. Most participants (92.0 %) reported that T2D and/or its treatment/monitoring requirements had an impact on their quality of life that was not captured by the EQ-5D-5L. Common missing concepts included food awareness/restriction (n = 13, 52.0 %); activities (n = 11, 44.0 %); emotional functioning other than depression/anxiety (n = 8, 32.0 %); and social/relationship functioning (n = 8, 32.0 %). The results highlight strengths and potential limitations of the EQ-5D-5L, including missing content that could be important for some patients with T2D. Suggestions for addressing limitations are provided.

  18. A Framework for Performing Verification and Validation in Reuse Based Software Engineering

    Science.gov (United States)

    Addy, Edward A.

    1997-01-01

    Verification and Validation (V&V) is currently performed during application development for many systems, especially safety-critical and mission- critical systems. The V&V process is intended to discover errors, especially errors related to critical processing, as early as possible during the development process. The system application provides the context under which the software artifacts are validated. This paper describes a framework that extends V&V from an individual application system to a product line of systems that are developed within an architecture-based software engineering environment. This framework includes the activities of traditional application-level V&V, and extends these activities into domain engineering and into the transition between domain engineering and application engineering. The framework includes descriptions of the types of activities to be performed during each of the life-cycle phases, and provides motivation for the activities.

  19. Synthesis and characterization of a 2D covalent organic framework ...

    Indian Academy of Sciences (India)

    RAMEES P P

    2018-04-27

    Apr 27, 2018 ... framework (COF) of hexagonal topology using boronate linkages ... of Chemistry, Indian Institute of Science Education and Research Bhopal, Bhopal By-Pass Road, ..... value is reliable with the theoretical pore size (2.7.

  20. SU-E-J-52: Validation of 3D Structure Projection Onto 2D DRR in Commercial Treatment Planning Systems.

    Science.gov (United States)

    Zhang, L; Court, L; Balter, P; Dong, L

    2012-06-01

    The use of structure overlay on setup DRRs can aid the image alignment procedure for daily image-guided setup procedures. However, the accuracy of a 3D region-of-interest (ROI) projected on a 2D digitally reconstructed radiograph (DRR) has rarely been evaluated quantitatively. The goal of this study is to test the accuracy of two commercial treatment planning systems (TPS) in producing overlay structures on setup DRRs. We designed a novel method to identify landmarks which were on the boundary of the projected ROI on a DRR. The 3D ROIvolume is composed of a stack of 2D curves. We first mathematically project each 2D curve onto a beams-eye-view (BEV) plane. Next, we detectthe boundary points of the projected curves. Those boundary points serve aslandmarks. Finally, we project the binary mask of the 3D ROI volume using ray tracing method onto the BEV plane. This projected binary mask is used to exclude the false landmarks. Once those landmarks are detected, wecompute the distance between the landmarks and ROI outlines from the TPS. We applied our validation method to 13 ROIs from a lung patient and 4 simulated ROIs on 2 BEV DRRs for two different TPS (Eclipse and Pinnacle). Average distance between the landmarks and ROIoutlines was 0.5mm for both Eclipse and Pinnacle approaches, which is close to the pixel resolution of the DRR. The maximum distance andaverage maximum distance was 2mm and 1 mm, respectively, for both TPS.The maximum distance occurred at points where the ROI curve has a sharpchange between slices. The accuracy of Eclipse and Pinnacle ROI projection method seems to be acceptable to within 1mm althoughprojection error can be as large as 2mm when structure shape has a sharp variation from one slice to the next. © 2012 American Association of Physicists in Medicine.

  1. A type of 2D magnetic equivalent circuit framework of permanent magnet for magnetic system in AEMR

    Directory of Open Access Journals (Sweden)

    Huimin Liang

    2015-02-01

    Full Text Available Modeling of permanent magnet (PM is very important in the process of electromagnetic system calculation of aerospace electromagnetic relay (AEMR. In traditional analytical calculation, PM is often equivalent to a lumped parameter model of one magnetic resistance and one magnetic potential, but great error is often caused for the inner differences of PM; based on the conception of flux tube, a type of 2D magnetic equivalent circuit framework of permanent magnet model (2D MECF is established; the element is defined, the relationship between elements is deduced, and solution procedure as well as verification condition of this model is given; by a case study of the electromagnetic system of a certain type of AEMR, the electromagnetic system calculation model is established based on 2D MECF and the attractive force at different rotation angles is calculated; the proposed method is compared with the traditional lumped parameter model and finite element method (FEM; for some types of electromagnetic systems with symmetrical structure, 2D MECF proves to be of acceptable accuracy and high calculation speed which fit the requirement of robust design for AEMR.

  2. Thermally activated 3D to 2D structural transformation of [Ni2(en)2(H2O)6(pyr)]·4H2O flexible coordination polymer

    International Nuclear Information System (INIS)

    Begović, Nebojša N.; Blagojević, Vladimir A.; Ostojić, Sanja B.; Radulović, Aleksandra M.; Poleti, Dejan; Minić, Dragica M.

    2015-01-01

    Thermally activated 3D to 2D structural transformation of the binuclear [Ni 2 (en) 2 (H 2 O) 6 (pyr)]·4H 2 O complex was investigated using a combination of theoretical and experimental methods. Step-wise thermal degradation (dehydration followed by release of ethylene diamine) results in two layered flexible coordination polymer structures. Dehydration process around 365 K results in a conjugated 2D structure with weak interlayer connectivity. It was shown to be a reversible 3D to 2D framework transformation by a guest molecule, and rehydration of the dehydration product occurs at room temperature in saturated water vapor. Rehydrated complex exhibits lower dehydration temperature, due to decreased average crystalline size, with higher surface area resulting in easier release and diffusion of water during dehydration. Thermal degradation of dehydration around 570 K, results in loss of ethylene diamine, producing a related 2D layered polymer structure, without interconnectivity between individual polymer layers. - Highlights: • Reversible 3D to 2D framework topochemical transformation on dehydration around 365 K. • Resulting polymer exhibits 2D layered structure with weak interlayer connectivity. • Dehydration is fully reversible in saturated water vapor at room temperature. • Further degradation around 570 K yields 2D polymer without interlayer connectivity. • 2D polymer exhibits conjugated electronic system

  3. Innovative therapeutic strategies against chemo and radio-resistant cancers: hydrogenated nano-diamonds and metal organic frameworks. An in vitro study in 2D and 3D systems

    International Nuclear Information System (INIS)

    Grall, Romain

    2015-01-01

    The present work focuses on nanoparticles and their great skills for oncology therapies. Two kinds of nanoparticles have been studied in order to biologically validate and characterize their features. The use of hydrogenated Nano-diamonds (H-NDs) as radio sensitizer is based on a physic-chemical postulate where they act as oxidative stress generator through interaction with irradiation. Thus we validated this hypothesis in radio resistant kidney and breast cancer cell lines and identify senescence as the main pathway after co-treatment with H-NDs and irradiation. Metal organic frameworks are also of particular interest for drug delivery because of their very important loading capacities. Here we demonstrate the biocompatibility of the empty compounds in four lung and hepatic cancer cell lines, a main point before their involvement in drug delivery strategies. Finally, following international guidelines encouraging to make animal testing more ethic, we developed a new 3D cell culture mimicking mucinous lung adenocarcinoma. This well characterized model will be used for the study of cancer development and drug screening. (author) [fr

  4. Quinoline derivative containing monomeric and polymeric metal carboxylates: Synthesis, crystal structure and gas adsorption study over a 2D layered framework

    Science.gov (United States)

    Gayen, Saikat; Saha, Debraj; Koner, Subratanath

    2018-06-01

    A new supramolecular metal-carboxylate framework [Co(mqc)2]n (1), and another monomeric compound [Zn (mqc)2(H2O)] (2) (mqcH = 4-methoxy 2-quinolinecarboxylic acid) have been synthesized solvothermally and characterized by single crystal X-ray diffraction, elemental analysis, IR spectra, UV-vis spectra, powdered X-ray diffraction (PXRD) and thermogravimetric analysis. Compound 1 is a 2D coordination polymer, extended to a 3D porous supramolecular network having void space in between 2D layers. Compound 1 exhibits gas uptake capacity of N2, H2, CO2 and CH4 like small gas molecules in which moderately high uptake of H2 and CO2 takes place among the 2D MOFs. While the Zn variety, compound 2 features a one-dimensional chain like structure through strong intermolecular hydrogen-bonding.

  5. Simulating streamer discharges in 3D with the parallel adaptive Afivo framework

    NARCIS (Netherlands)

    H.J. Teunissen (Jannis); U. M. Ebert (Ute)

    2017-01-01

    htmlabstractWe present an open-source plasma fluid code for 2D, cylindrical and 3D simulations of streamer discharges, based on the Afivo framework that features adaptive mesh refinement, geometric multigrid methods for Poisson's equation, and OpenMP parallelism. We describe the numerical

  6. Validation of a motion-robust 2D sequential technique for quantification of hepatic proton density fat fraction during free breathing.

    Science.gov (United States)

    Pooler, B Dustin; Hernando, Diego; Ruby, Jeannine A; Ishii, Hiroshi; Shimakawa, Ann; Reeder, Scott B

    2018-04-17

    Current chemical-shift-encoded (CSE) MRI techniques for measuring hepatic proton density fat fraction (PDFF) are sensitive to motion artifacts. Initial validation of a motion-robust 2D-sequential CSE-MRI technique for quantification of hepatic PDFF. Phantom study and prospective in vivo cohort. Fifty adult patients (27 women, 23 men, mean age 57.2 years). 3D, 2D-interleaved, and 2D-sequential CSE-MRI acquisitions at 1.5T. Three CSE-MRI techniques (3D, 2D-interleaved, 2D-sequential) were performed in a PDFF phantom and in vivo. Reference standards were 3D CSE-MRI PDFF measurements for the phantom study and single-voxel MR spectroscopy hepatic PDFF measurements (MRS-PDFF) in vivo. In vivo hepatic MRI-PDFF measurements were performed during a single breath-hold (BH) and free breathing (FB), and were repeated by a second reader for the FB 2D-sequential sequence to assess interreader variability. Correlation plots to validate the 2D-sequential CSE-MRI against the phantom and in vivo reference standards. Bland-Altman analysis of FB versus BH CSE-MRI acquisitions to evaluate robustness to motion. Bland-Altman analysis to assess interreader variability. Phantom 2D-sequential CSE-MRI PDFF measurements demonstrated excellent agreement and correlation (R 2 > 0.99) with 3D CSE-MRI. In vivo, the mean (±SD) hepatic PDFF was 8.8 ± 8.7% (range 0.6-28.5%). Compared with BH acquisitions, FB hepatic PDFF measurements demonstrated bias of +0.15% for 2D-sequential compared with + 0.53% for 3D and +0.94% for 2D-interleaved. 95% limits of agreement (LOA) were narrower for 2D-sequential (±0.99%), compared with 3D (±3.72%) and 2D-interleaved (±3.10%). All CSE-MRI techniques had excellent correlation with MRS (R 2 > 0.97). The FB 2D-sequential acquisition demonstrated little interreader variability, with mean bias of +0.07% and 95% LOA of ± 1.53%. This motion-robust 2D-sequential CSE-MRI can accurately measure hepatic PDFF during free breathing in a patient population with

  7. AIMD - a validated, simplified framework of interventions to promote and integrate evidence into health practices, systems, and policies

    Directory of Open Access Journals (Sweden)

    Peter Bragge

    2017-03-01

    Full Text Available Abstract Background Proliferation of terms describing the science of effectively promoting and supporting the use of research evidence in healthcare policy and practice has hampered understanding and development of the field. To address this, an international Terminology Working Group developed and published a simplified framework of interventions to promote and integrate evidence into health practices, systems, and policies. This paper presents results of validation work and a second international workgroup meeting, culminating in the updated AIMD framework [Aims, Ingredients, Mechanism, Delivery]. Methods Framework validity was evaluated against terminology schemas (n = 51; primary studies (n = 37; and reporting guidelines (n = 10. Framework components were independently categorized as fully represented, partly represented, or absent by two researchers. Opportunities to refine the framework were systematically recorded. A meeting of the expanded international Terminology Working Group updated the framework by reviewing and deliberating upon validation findings and refinement proposals. Results There was variation in representativeness of the components across the three types of literature, in particular for the component ‘causal mechanisms’. Analysis of primary studies revealed that representativeness of this concept lowered from 92 to 68% if only explicit, rather than explicit and non-explicit references to causal mechanisms were included. All components were very well represented in reporting guidelines, however the level of description of these was lower than in other types of literature. Twelve opportunities were identified to improve the framework, 9 of which were operationalized at the meeting. The updated AIMD framework comprises four components: (1 Aims: what do you want your intervention to achieve and for whom? (2 Ingredients: what comprises the intervention? (3 Mechanisms: how do you propose the intervention will

  8. The reliability and criterion validity of 2D video assessment of single leg squat and hop landing.

    Science.gov (United States)

    Herrington, Lee; Alenezi, Faisal; Alzhrani, Msaad; Alrayani, Hasan; Jones, Richard

    2017-06-01

    The objective was to assess the intra-tester, within and between day reliability of measurement of hip adduction (HADD) and frontal plane projection angles (FPPA) during single leg squat (SLS) and single leg landing (SLL) using 2D video and the validity of these measurements against those found during 3D motion capture. 15 healthy subjects had their SLS and SLL assessed using 3D motion capture and video analysis. Inter-tester reliability for both SLS and SLL when measuring FPPA and HADD show excellent correlations (ICC 2,1 0.97-0.99). Within and between day assessment of SLS and SLL showed good to excellent correlations for both variables (ICC 3,1 0.72-91). 2D FPPA measures were found to have good correlation with knee abduction angle in 3-D (r=0.79, p=0.008) during SLS, and also to knee abduction moment (r=0.65, p=0.009). 2D HADD showed very good correlation with 3D HADD during SLS (r=0.81, p=0.001), and a good correlation during SLL (r=0.62, p=0.013). All other associations were weak (r<0.4). This study suggests that 2D video kinematics have a reasonable association to what is being measured with 3D motion capture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. 3D strata objectsregistration for Malaysia within the LADM framework

    OpenAIRE

    Zulkifli, N.A.; Abdul Rahman, A.; Van Oosterom, P.J.M.

    2011-01-01

    This paper discusses 3D objects registration and modelling for cadastral objects within the Land Administration Domain Model (LADM) framework. A conceptual model as well as the associated technical model for the 2D and 3D objects have been proposed and developed for Malaysia. For both private and public land, the main subdivision of land in Malaysia is based on lots. In many continental European countries, ‘lot’ would be called ‘parcel’, but ‘parcel’ has other meaning in Malaysian context. Th...

  10. Modeling Root Growth, Crop Growth and N Uptake of Winter Wheat Based on SWMS_2D: Model and Validation

    Directory of Open Access Journals (Sweden)

    Dejun Yang

    Full Text Available ABSTRACT Simulations for root growth, crop growth, and N uptake in agro-hydrological models are of significant concern to researchers. SWMS_2D is one of the most widely used physical hydrologically related models. This model solves equations that govern soil-water movement by the finite element method, and has a public access source code. Incorporating key agricultural components into the SWMS_2D model is of practical importance, especially for modeling some critical cereal crops such as winter wheat. We added root growth, crop growth, and N uptake modules into SWMS_2D. The root growth model had two sub-models, one for root penetration and the other for root length distribution. The crop growth model used was adapted from EU-ROTATE_N, linked to the N uptake model. Soil-water limitation, nitrogen limitation, and temperature effects were all considered in dry-weight modeling. Field experiments for winter wheat in Bouwing, the Netherlands, in 1983-1984 were selected for validation. Good agreements were achieved between simulations and measurements, including soil water content at different depths, normalized root length distribution, dry weight and nitrogen uptake. This indicated that the proposed new modules used in the SWMS_2D model are robust and reliable. In the future, more rigorous validation should be carried out, ideally under 2D situations, and attention should be paid to improve some modules, including the module simulating soil N mineralization.

  11. Examining students' views about validity of experiments: From introductory to Ph.D. students

    Science.gov (United States)

    Hu, Dehui; Zwickl, Benjamin M.

    2018-06-01

    We investigated physics students' epistemological views on measurements and validity of experimental results. The roles of experiments in physics have been underemphasized in previous research on students' personal epistemology, and there is a need for a broader view of personal epistemology that incorporates experiments. An epistemological framework incorporating the structure, methodology, and validity of scientific knowledge guided the development of an open-ended survey. The survey was administered to students in algebra-based and calculus-based introductory physics courses, upper-division physics labs, and physics Ph.D. students. Within our sample, we identified several differences in students' ideas about validity and uncertainty in measurement. The majority of introductory students justified the validity of results through agreement with theory or with results from others. Alternatively, Ph.D. students frequently justified the validity of results based on the quality of the experimental process and repeatability of results. When asked about the role of uncertainty analysis, introductory students tended to focus on the representational roles (e.g., describing imperfections, data variability, and human mistakes). However, advanced students focused on the inferential roles of uncertainty analysis (e.g., quantifying reliability, making comparisons, and guiding refinements). The findings suggest that lab courses could emphasize a variety of approaches to establish validity, such as by valuing documentation of the experimental process when evaluating the quality of student work. In order to emphasize the role of uncertainty in an authentic way, labs could provide opportunities to iterate, make repeated comparisons, and make decisions based on those comparisons.

  12. A proposed framework for computational fluid dynamics code calibration/validation

    International Nuclear Information System (INIS)

    Oberkampf, W.L.

    1993-01-01

    The paper reviews the terminology and methodology that have been introduced during the last several years for building confidence n the predictions from Computational Fluid Dynamics (CID) codes. Code validation terminology developed for nuclear reactor analyses and aerospace applications is reviewed and evaluated. Currently used terminology such as ''calibrated code,'' ''validated code,'' and a ''validation experiment'' is discussed along with the shortcomings and criticisms of these terms. A new framework is proposed for building confidence in CFD code predictions that overcomes some of the difficulties of past procedures and delineates the causes of uncertainty in CFD predictions. Building on previous work, new definitions of code verification and calibration are proposed. These definitions provide more specific requirements for the knowledge level of the flow physics involved and the solution accuracy of the given partial differential equations. As part of the proposed framework, categories are also proposed for flow physics research, flow modeling research, and the application of numerical predictions. The contributions of physical experiments, analytical solutions, and other numerical solutions are discussed, showing that each should be designed to achieve a distinctively separate purpose in building confidence in accuracy of CFD predictions. A number of examples are given for each approach to suggest methods for obtaining the highest value for CFD code quality assurance

  13. A structure-based approach to ligand discovery for 2C-methyl-D-erythritol-2,4-cyclodiphosphate synthase: a target for antimicrobial therapy.

    Science.gov (United States)

    Ramsden, Nicola L; Buetow, Lori; Dawson, Alice; Kemp, Lauris A; Ulaganathan, Venkatsubramanian; Brenk, Ruth; Klebe, Gerhard; Hunter, William N

    2009-04-23

    The nonmevalonate route to isoprenoid biosynthesis is essential in Gram-negative bacteria and apicomplexan parasites. The enzymes of this pathway are absent from mammals, contributing to their appeal as chemotherapeutic targets. One enzyme, 2C-methyl-d-erythritol-2,4-cyclodiphosphate synthase (IspF), has been validated as a target by genetic approaches in bacteria. Virtual screening against Escherichia coli IspF (EcIspF) was performed by combining a hierarchical filtering methodology with molecular docking. Docked compounds were inspected and 10 selected for experimental validation. A surface plasmon resonance assay was developed and two weak ligands identified. Crystal structures of EcIspF complexes were determined to support rational ligand development. Cytosine analogues and Zn(2+)-binding moieties were characterized. One of the putative Zn(2+)-binding compounds gave the lowest measured K(D) to date (1.92 +/- 0.18 muM). These data provide a framework for the development of IspF inhibitors to generate lead compounds of therapeutic potential against microbial pathogens.

  14. Developmental framework to validate future designs of ballistic neck protection.

    Science.gov (United States)

    Breeze, J; Midwinter, M J; Pope, D; Porter, K; Hepper, A E; Clasper, J

    2013-01-01

    The number of neck injuries has increased during the war in Afghanistan, and they have become an appreciable source of mortality and long-term morbidity for UK servicemen. A three-dimensional numerical model of the neck is necessary to allow simulation of penetrating injury from explosive fragments so that the design of body armour can be optimal, and a framework is required to validate and describe the individual components of this program. An interdisciplinary consensus group consisting of military maxillofacial surgeons, and biomedical, physical, and material scientists was convened to generate the components of the framework, and as a result it incorporates the following components: analysis of deaths and long-term morbidity, assessment of critical cervical structures for incorporation into the model, characterisation of explosive fragments, evaluation of the material of which the body armour is made, and mapping of the entry sites of fragments. The resulting numerical model will simulate the wound tract produced by fragments of differing masses and velocities, and illustrate the effects of temporary cavities on cervical neurovascular structures. Using this framework, a new shirt to be worn under body armour that incorporates ballistic cervical protection has been developed for use in Afghanistan. New designs of the collar validated by human factors and assessment of coverage are currently being incorporated into early versions of the numerical model. The aim of this paper is to describe this developmental framework and provide an update on the current progress of its individual components. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  15. Validity of Type D personality in Iceland

    DEFF Research Database (Denmark)

    Svansdottir, Erla; Karlsson, Hrobjartur D; Gudnason, Thorarinn

    2012-01-01

    was 26-29%, and assessment of Type D personality was not confounded by severity of underlying coronary artery disease. Regarding risk markers, Type D patients reported more psychopharmacological medication use and smoking, but frequency of previous mental problems was similar across groups. Type D......Type D personality has been associated with poor prognosis in cardiac patients. This study investigated the validity of the Type D construct in Iceland and its association with disease severity and health-related risk markers in cardiac patients. A sample of 1,452 cardiac patients completed...... the Type D scale (DS14), and a subgroup of 161 patients completed measurements for the five-factor model of personality, emotional control, anxiety, depression, stress and lifestyle factors. The Icelandic DS14 had good psychometric properties and its construct validity was confirmed. Prevalence of Type D...

  16. An Automated Defect Prediction Framework using Genetic Algorithms: A Validation of Empirical Studies

    Directory of Open Access Journals (Sweden)

    Juan Murillo-Morera

    2016-05-01

    Full Text Available Today, it is common for software projects to collect measurement data through development processes. With these data, defect prediction software can try to estimate the defect proneness of a software module, with the objective of assisting and guiding software practitioners. With timely and accurate defect predictions, practitioners can focus their limited testing resources on higher risk areas. This paper reports the results of three empirical studies that uses an automated genetic defect prediction framework. This framework generates and compares different learning schemes (preprocessing + attribute selection + learning algorithms and selects the best one using a genetic algorithm, with the objective to estimate the defect proneness of a software module. The first empirical study is a performance comparison of our framework with the most important framework of the literature. The second empirical study is a performance and runtime comparison between our framework and an exhaustive framework. The third empirical study is a sensitivity analysis. The last empirical study, is our main contribution in this paper. Performance of the software development defect prediction models (using AUC, Area Under the Curve was validated using NASA-MDP and PROMISE data sets. Seventeen data sets from NASA-MDP (13 and PROMISE (4 projects were analyzed running a NxM-fold cross-validation. A genetic algorithm was used to select the components of the learning schemes automatically, and to assess and report the results. Our results reported similar performance between frameworks. Our framework reported better runtime than exhaustive framework. Finally, we reported the best configuration according to sensitivity analysis.

  17. Novel metal-organic and supramolecular 3D frameworks constructed from flexible biphenyl-2,5,3‧-tricarboxylate blocks: Synthesis, structural features and properties

    Science.gov (United States)

    You, Ao; Li, Yu; Zhang, Ze-Min; Zou, Xun-Zhong; Gu, Jin-Zhong; Kirillov, Alexander M.; Chen, Jin-Wei; Chen, Yun-Bo

    2017-10-01

    Biphenyl-2,5,3‧-tricarboxylic acid (H3L) was selected as an unexplored tricarboxylate building block and applied for the hydrothermal synthesis of three novel coordination compounds, namely a 0D tetramer [Co4(HL)2(μ3-HL)2(phen)6(H2O)2]·3H2O (1) and two 3D metal-organic frameworks (MOFs) [Cd3(μ5-L)(μ6-L)(py)(μ-H2O)2(H2O)]n·H2O (2) and [Zn3(μ4-L)2(2,2‧-bpy)(μ-4,4‧-bpy)]n·2H2O (3). These products were easily generated in aqueous medium from the corresponding metal(II) chlorides, H3L, and various N-donor ancillary ligands, selected from 1,10-phenanthroline (phen), pyridine (py), 2,2‧-bipyridine (2,2‧-bpy), and 4,4‧-bipyridine (4,4‧-bpy). Compounds 1-3 were isolated as stable crystalline solids and were fully characterized by IR and UV-vis spectroscopy, elemental, thermogravimetric (TGA), powder (PXRD) and single-crystal X-ray diffraction analyses. Compound 1 possesses a discrete tetracobalt(II) structure, which is extended into a 3D H-bonded network with the pcu topology. In contrast, MOF 2 discloses a very complex trinodal 4,5,12-connected net with an undocumented topology, while MOF 3 features the nce/I topological framework. The magnetic (for 1) and luminescence (for 2 and 3) properties were also studied and discussed. The present study thus widens a still very limited family of metal-organic and supramolecular frameworks driven by flexible biphenyl-2,5,3‧-tricarboxylate building blocks.

  18. Validation of the turkish version of the centre for epidemiologic studies depression scale (ces-d in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Karşıdağ Kubilay

    2011-07-01

    Full Text Available Abstract Background Depression is a common co-morbid health problem in patients with diabetes that is underrecognised. Current international guidelines recommend screening for depression in patients with diabetes. Yet, few depression screening instruments have been validated for use in this particular group of patients. Aim of the present study was to investigate the psychometric properties of the Turkish version of the Centre for Epidemiologic Studies Depression Scale (CES-D in patients with type 2 diabetes. Methods A sample of 151 Turkish outpatients with type 2 diabetes completed the CES-D, the World Health Organization-Five Well-Being Index (WHO-5, and the Problem Areas in Diabetes scale (PAID. Explanatory factor analyses, various correlations and Cronbach's alpha were investigated to test the validity and reliability of the CES-D in Turkish diabetes outpatients. Results The original four-factor structure proposed by Radloff was not confirmed. Explanatory factor analyses revealed a two-factor structure representing two subscales: (1 depressed mood combined with somatic symptoms of depression and (2 positive affect. However, one item showed insufficient factor loadings. Cronbach's alpha of the total score was high (0.88, as were split-half coefficients (0.77-0.90. The correlation of the CES-D with the WHO-5 was the strongest (r = -0.70, and supported concurrent validity. Conclusion The CES-D appears to be a valid measure for the assessment of depression in Turkish diabetes patients. Future studies should investigate its sensitivity and specificity as well as test-retest reliability.

  19. 2D Metal-Organic Frameworks Derived Nanocarbon Arrays for Substrate Enhancement in Flexible Supercapacitors.

    Science.gov (United States)

    Liu, Ximeng; Guan, Cao; Hu, Yating; Zhang, Lei; Elshahawy, Abdelnaby M; Wang, John

    2017-10-27

    Direct assembling of active materials on carbon cloth (CC) is a promising way to achieve flexible electrodes for energy storage. However, the overall surface area and electrical conductivity of such electrodes are usually limited. Herein, 2D metal-organic framework derived nanocarbon nanowall (MOFC) arrays are successfully developed on carbon cloth by a facile solution + carbonization process. Upon growth of the MOFC arrays, the sites for growth of the active materials are greatly increased, and the equivalent series resistance is decreased, which contribute to the enhancement of the bare CC substrate. After decorating ultrathin flakes of MnO 2 and Bi 2 O 3 on the flexible CC/MOFC substrate, the hierarchical electrode materials show an abrupt improvement of areal capacitances by around 50% and 100%, respectively, compared to those of the active materials on pristine carbon cloth. A flexible supercapacitor can be further assembled using two hierarchical electrodes, which demonstrates an energy density of 124.8 µWh cm -2 at the power density of 2.55 mW cm -2 . © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Methods for Geometric Data Validation of 3d City Models

    Science.gov (United States)

    Wagner, D.; Alam, N.; Wewetzer, M.; Pries, M.; Coors, V.

    2015-12-01

    Geometric quality of 3D city models is crucial for data analysis and simulation tasks, which are part of modern applications of the data (e.g. potential heating energy consumption of city quarters, solar potential, etc.). Geometric quality in these contexts is however a different concept as it is for 2D maps. In the latter case, aspects such as positional or temporal accuracy and correctness represent typical quality metrics of the data. They are defined in ISO 19157 and should be mentioned as part of the metadata. 3D data has a far wider range of aspects which influence their quality, plus the idea of quality itself is application dependent. Thus, concepts for definition of quality are needed, including methods to validate these definitions. Quality on this sense means internal validation and detection of inconsistent or wrong geometry according to a predefined set of rules. A useful starting point would be to have correct geometry in accordance with ISO 19107. A valid solid should consist of planar faces which touch their neighbours exclusively in defined corner points and edges. No gaps between them are allowed, and the whole feature must be 2-manifold. In this paper, we present methods to validate common geometric requirements for building geometry. Different checks based on several algorithms have been implemented to validate a set of rules derived from the solid definition mentioned above (e.g. water tightness of the solid or planarity of its polygons), as they were developed for the software tool CityDoctor. The method of each check is specified, with a special focus on the discussion of tolerance values where they are necessary. The checks include polygon level checks to validate the correctness of each polygon, i.e. closeness of the bounding linear ring and planarity. On the solid level, which is only validated if the polygons have passed validation, correct polygon orientation is checked, after self-intersections outside of defined corner points and edges

  1. D1.5 WEKIT Framework and Training Methodology

    NARCIS (Netherlands)

    Limbu, Bibeg

    2017-01-01

    The document reports on the status of the WEKIT framework. Building up on the methodologies described in D1.3, it outlines the work done and progress made so far in the Task 1.3. The WEKIT framework was drafted to guide and support the development and implementation of the project. It aims to

  2. Establishing a framework to implement 4D XCAT Phantom for 4D radiotherapy research

    Directory of Open Access Journals (Sweden)

    Raj K Panta

    2012-01-01

    Conclusions: An integrated computer program has been developed to generate, review, analyse, process, and export the 4D XCAT images. A framework has been established to implement the 4D XCAT phantom for 4D RT research.

  3. 2D/ 3D Quantitative Ultrasound of the Breast

    Science.gov (United States)

    Nasief, Haidy Gerges

    Breast cancer is the second leading cause of cancer death of women in the United States, so breast cancer screening for early detection is common. The purpose of this dissertation is to optimize quantitative ultrasound (QUS) methods to improve the specificity and objectivity of breast ultrasound. To pursue this goal, the dissertation is divided into two parts: 1) to optimize 2D QUS, and 2) to introduce and validate 3D QUS. Previous studies had validated these methods in phantoms. Applying our QUS analysis on subcutaneous breast fat demonstrated that QUS parameter estimates for subcutaneous fat were consistent among different human subjects. This validated our in vivo data acquisition methods and supported the use of breast fat as a clinical reference tissue for ultrasound BI-RADSRTM assessments. Although current QUS methods perform well for straightforward cases when assumptions of stationarity and diffuse scattering are well-founded, these conditions often are not present due to the complicated nature of in vivo breast tissue. Key improvements in QUS algorithms to address these challenges were: 1) applying a "modified least squares method (MLSM)" to account for the heterogeneous tissue path between the transducer and the region of interest, ROI; 2) detecting anisotropy in acoustic parameters; and 3) detecting and removing the echo sources that depart from diffuse and stationary scattering conditions. The results showed that a Bayesian classifier combining three QUS parameters in a biased pool of high-quality breast ultrasound data successfully differentiated all fibroadenomas from all carcinomas. Given promising initial results in 2D, extension to 3D acquisitions in QUS provided a unique capability to test QUS for the entire breast volume. QUS parameter estimates using 3D data were consistent with those found in 2D for phantoms and in vivo data. Extensions of QUS technology from 2D to 3D can improve the specificity of breast ultrasound, and thus, could lead to

  4. Ensemble Kalman filter regularization using leave-one-out data cross-validation

    KAUST Repository

    Rayo Schiappacasse, Lautaro Jerónimo

    2012-09-19

    In this work, the classical leave-one-out cross-validation method for selecting a regularization parameter for the Tikhonov problem is implemented within the EnKF framework. Following the original concept, the regularization parameter is selected such that it minimizes the predictive error. Some ideas about the implementation, suitability and conceptual interest of the method are discussed. Finally, what will be called the data cross-validation regularized EnKF (dCVr-EnKF) is implemented in a 2D 2-phase synthetic oil reservoir experiment and the results analyzed.

  5. Validation of a Framework for Measuring Hospital Disaster Resilience Using Factor Analysis

    Directory of Open Access Journals (Sweden)

    Shuang Zhong

    2014-06-01

    Full Text Available Hospital disaster resilience can be defined as “the ability of hospitals to resist, absorb, and respond to the shock of disasters while maintaining and surging essential health services, and then to recover to its original state or adapt to a new one.” This article aims to provide a framework which can be used to comprehensively measure hospital disaster resilience. An evaluation framework for assessing hospital resilience was initially proposed through a systematic literature review and Modified-Delphi consultation. Eight key domains were identified: hospital safety, command, communication and cooperation system, disaster plan, resource stockpile, staff capability, disaster training and drills, emergency services and surge capability, and recovery and adaptation. The data for this study were collected from 41 tertiary hospitals in Shandong Province in China, using a specially designed questionnaire. Factor analysis was conducted to determine the underpinning structure of the framework. It identified a four-factor structure of hospital resilience, namely, emergency medical response capability (F1, disaster management mechanisms (F2, hospital infrastructural safety (F3, and disaster resources (F4. These factors displayed good internal consistency. The overall level of hospital disaster resilience (F was calculated using the scoring model: F = 0.615F1 + 0.202F2 + 0.103F3 + 0.080F4. This validated framework provides a new way to operationalise the concept of hospital resilience, and it is also a foundation for the further development of the measurement instrument in future studies.

  6. Validation of a 2-D semi-coupled numerical model for fluid-structure-seabed interaction

    Science.gov (United States)

    Ye, Jianhong; Jeng, Dongsheng; Wang, Ren; Zhu, Changqi

    2013-10-01

    A 2-D semi-coupled model PORO-WSSI 2D (also be referred as FSSI-CAS 2D) for the Fluid-Structure-Seabed Interaction (FSSI) has been developed by employing RANS equations for wave motion in fluid domain, VARANS equations for porous flow in porous structures; and taking the dynamic Biot's equations (known as "u - p" approximation) for soil as the governing equations. The finite difference two-step projection method and the forward time difference method are adopted to solve the RANS, VARANS equations; and the finite element method is adopted to solve the "u - p" approximation. A data exchange port is developed to couple the RANS, VARANS equations and the dynamic Biot's equations together. The analytical solution proposed by Hsu and Jeng (1994) and some experiments conducted in wave flume or geotechnical centrifuge in which various waves involved are used to validate the developed semi-coupled numerical model. The sandy bed involved in these experiments is poro-elastic or poro-elastoplastic. The inclusion of the interaction between fluid, marine structures and poro-elastoplastic seabed foundation is a special point and highlight in this paper, which is essentially different with other previous coupled models The excellent agreement between the numerical results and the experiment data indicates that the developed coupled model is highly reliablefor the FSSI problem.

  7. MARVEL analysis of the rotational-vibrational states of the molecular ions H2D+ and D2H+.

    Science.gov (United States)

    Furtenbacher, Tibor; Szidarovszky, Tamás; Fábri, Csaba; Császár, Attila G

    2013-07-07

    Critically evaluated rotational-vibrational line positions and energy levels, with associated critically reviewed labels and uncertainties, are reported for two deuterated isotopologues of the H3(+) molecular ion: H2D(+) and D2H(+). The procedure MARVEL, standing for Measured Active Rotational-Vibrational Energy Levels, is used to determine the validated levels and lines and their self-consistent uncertainties based on the experimentally available information. The spectral ranges covered for the isotopologues H2D(+) and D2H(+) are 5.2-7105.5 and 23.0-6581.1 cm(-1), respectively. The MARVEL energy levels of the ortho and para forms of the ions are checked against ones determined from accurate variational nuclear motion computations employing the best available adiabatic ab initio potential energy surfaces of these isotopologues. The number of critically evaluated, validated and recommended experimental (levels, lines) are (109, 185) and (104, 136) for H2D(+) and D2H(+), respectively. The lists of assigned MARVEL lines and levels and variational levels obtained for H2D(+) and D2H(+) as part of this study are deposited in the ESI to this paper.

  8. A new electrochemically responsive 2D π-conjugated covalent organic framework as a high performance supercapacitor

    KAUST Repository

    Das, Sabuj Kanti

    2018-03-02

    Covalent organic frameworks (COFs) build via periodic arrangement of organic building blocks are attracting increasing interest in recent times due to the huge scope in their synthesis through a wide range of structural motifs and diversity in their potential applications. Here we report the synthesis of a new porous extended network π-conjugated TFP-NDA-COF via solvothermal Schiff base condensation of 1,3,5-triformylphloroglucinol (TFP) with 1,5-diaminonaphthalene (NDA). The electrochemical study demonstrates that TFP-NDA-COF has the capability of energy storage up to 379 F g−1 at 2 mV s−1 scan rate, 348 F g−1 at 0.5 A g−1 and offer excellent specific capacitance retention of 75% after 8000 charge discharge cycles. High electrochemical performance could be attributed to the π-electronic conjugation along the polymeric 2D layered network and ion conduction inside the porous channel and permanent porosity of the framework. This indicates that the COF reported herein meets the key requirements like energy storage ability and electrochemical stability needed for developing an efficient energy storage device.

  9. A new electrochemically responsive 2D π-conjugated covalent organic framework as a high performance supercapacitor

    KAUST Repository

    Das, Sabuj Kanti; Bhunia, Kousik; Mallick, Arijit; Pradhan, Anirban; Pradhan, Debabrata; Bhaumik, Asim

    2018-01-01

    Covalent organic frameworks (COFs) build via periodic arrangement of organic building blocks are attracting increasing interest in recent times due to the huge scope in their synthesis through a wide range of structural motifs and diversity in their potential applications. Here we report the synthesis of a new porous extended network π-conjugated TFP-NDA-COF via solvothermal Schiff base condensation of 1,3,5-triformylphloroglucinol (TFP) with 1,5-diaminonaphthalene (NDA). The electrochemical study demonstrates that TFP-NDA-COF has the capability of energy storage up to 379 F g−1 at 2 mV s−1 scan rate, 348 F g−1 at 0.5 A g−1 and offer excellent specific capacitance retention of 75% after 8000 charge discharge cycles. High electrochemical performance could be attributed to the π-electronic conjugation along the polymeric 2D layered network and ion conduction inside the porous channel and permanent porosity of the framework. This indicates that the COF reported herein meets the key requirements like energy storage ability and electrochemical stability needed for developing an efficient energy storage device.

  10. Providing Fast Discovery in D2D Communication with Full Duplex Technology

    DEFF Research Database (Denmark)

    Gatnau, Marta; Berardinelli, Gilberto; Mahmood, Nurul Huda

    2016-01-01

    technology to provide D2D fast discovery. Such framework provides an algorithm to estimate the number of neighbor devices and to dynamically decide the transmission probability, for adapting to network changes and meeting the 10 milliseconds target. Finally, a signaling scheme is proposed to reduce......In Direct Device-to-Device (D2D), the device awareness procedure known as the discovery phase is required prior to the exchange of data. This work considers autonomous devices where the infrastructure is not involved in the discovery procedure. Commonly, the transmission of the discovery message...... the network interference. Results show that our framework performs better than a static approach, reducing the time it takes to complete the discovery phase. In addition, supporting full duplex allows to further reduce the discovery time compared to half duplex transmission mode....

  11. Development and Validation of a Quantitative Framework and Management Expectation Tool for the Selection of Bioremediation Approaches at Chlorinated Ethene Sites

    Science.gov (United States)

    2015-12-01

    FINAL REPORT Development and Validation of a Quantitative Framework and Management Expectation Tool for the Selection of Bioremediation ...TITLE AND SUBTITLE Development and Validation of a Quantitative Framework and Management Expectation Tool for the Selection of Bioremediation ...project ER-201129 was to develop and validate a framework used to make bioremediation decisions based on site-specific physical and biogeochemical

  12. Development, validation and application of NAFA 2D-CFD code

    International Nuclear Information System (INIS)

    Vaidya, A.M.; Maheshwari, N.K.; Vijayan, P.K.; Saha, D.

    2010-01-01

    A 2D axi-symmetric code named NAFA (Version 1.0) is developed for studying the pipe flow under various conditions. It can handle laminar/ turbulent flows, with or without heat transfer, under sub-critical/super-critical conditions. The code solves for momentum, energy equations with standard k-ε turbulence model (with standard wall functions). It solves pipe flow subjected to 'velocity inlet', 'wall', 'axis' and 'pressure outlet' boundary conditions. It is validated for several cases by comparing its results with experimental data/analytical solutions/correlations. The code has excellent convergence characteristics as verified from fall of equation residual in each case. It has proven capability of generating mesh independent results for laminar as well as turbulent flows. The code is applied to supercritical flows. For supercritical flows, the effect of mesh size on prediction of heat transfer coefficient is studied. With grid refinement, the Y + reduces and reaches the limiting value of 11.63. Hence the accuracy is found to increase with grid refinement. NAFA is able to qualitatively predict the effect of heat flux and operating pressure on heat transfer coefficient. The heat transfer coefficient matches well with experimental values under various conditions. (author)

  13. From 2D Silhouettes to 3D Object Retrieval: Contributions and Benchmarking

    Directory of Open Access Journals (Sweden)

    Napoléon Thibault

    2010-01-01

    Full Text Available 3D retrieval has recently emerged as an important boost for 2D search techniques. This is mainly due to its several complementary aspects, for instance, enriching views in 2D image datasets, overcoming occlusion and serving in many real-world applications such as photography, art, archeology, and geolocalization. In this paper, we introduce a complete "2D photography to 3D object" retrieval framework. Given a (collection of picture(s or sketch(es of the same scene or object, the method allows us to retrieve the underlying similar objects in a database of 3D models. The contribution of our method includes (i a generative approach for alignment able to find canonical views consistently through scenes/objects and (ii the application of an efficient but effective matching method used for ranking. The results are reported through the Princeton Shape Benchmark and the Shrec benchmarking consortium evaluated/compared by a third party. In the two gallery sets, our framework achieves very encouraging performance and outperforms the other runs.

  14. Estimating 3D Object Parameters from 2D Grey-Level Images

    NARCIS (Netherlands)

    Houkes, Z.

    2000-01-01

    This thesis describes a general framework for parameter estimation, which is suitable for computer vision applications. The approach described combines 3D modelling, animation and estimation tools to determine parameters of objects in a scene from 2D grey-level images. The animation tool predicts

  15. Validation of a clinical leadership qualities framework for managers in aged care: a Delphi study.

    Science.gov (United States)

    Jeon, Yun-Hee; Conway, Jane; Chenoweth, Lynn; Weise, Janelle; Thomas, Tamsin Ht; Williams, Anna

    2015-04-01

    To establish validity of a clinical leadership framework for aged care middle managers (The Aged care Clinical Leadership Qualities Framework). Middle managers in aged care have responsibility not only for organisational governance also and operational management but also quality service delivery. There is a need to better define clinical leadership abilities in aged care middle managers, in order to optimise their positional authority to lead others to achieve quality outcomes. A Delphi method. Sixty-nine experts in aged care were recruited, representing rural, remote and metropolitan community and residential aged care settings. Panellists were asked to rate the proposed framework in terms of the relevance and importance of each leadership quality using four-point Likert scales, and to provide comments. Three rounds of consultation were conducted. The number and corresponding percentage of the relevance and importance rating for each quality was calculated for each consultation round, as well as mean scores. Consensus was determined to be reached when a percentage score reached 70% or greater. Twenty-three panellists completed all three rounds of consultation. Following the three rounds of consultation, the acceptability and face validity of the framework was confirmed. The study confirmed the framework as useful in identifying leadership requirements for middle managers in Australian aged care settings. The framework is the first validated framework of clinical leadership attributes for middle managers in aged care and offers an initial step forward in clarifying the aged care middle manager role. The framework provides clarity in the breadth of role expectations for the middle managers and can be used to inform an aged care specific leadership program development, individuals' and organisations' performance and development processes; and policy and guidelines about the types of activities required of middle managers in aged care. © 2014 John Wiley & Sons Ltd.

  16. Thermally activated 3D to 2D structural transformation of [Ni{sub 2}(en){sub 2}(H{sub 2}O){sub 6}(pyr)]·4H{sub 2}O flexible coordination polymer

    Energy Technology Data Exchange (ETDEWEB)

    Begović, Nebojša N. [Faculty of Physical Chemistry, University of Belgrade (Serbia); Institute of General and Physical Chemistry, Belgrade (Serbia); Blagojević, Vladimir A. [Faculty of Physical Chemistry, University of Belgrade (Serbia); Ostojić, Sanja B.; Radulović, Aleksandra M. [Institute of General and Physical Chemistry, Belgrade (Serbia); Poleti, Dejan [Faculty of Technology and Metallurgy, University of Belgrade (Serbia); Minić, Dragica M., E-mail: dminic@ffh.bg.ac.rs [Faculty of Physical Chemistry, University of Belgrade (Serbia); Department of Biomedical Sciences, State University of Novi Pazar (Serbia)

    2015-01-15

    Thermally activated 3D to 2D structural transformation of the binuclear [Ni{sub 2}(en){sub 2}(H{sub 2}O){sub 6}(pyr)]·4H{sub 2}O complex was investigated using a combination of theoretical and experimental methods. Step-wise thermal degradation (dehydration followed by release of ethylene diamine) results in two layered flexible coordination polymer structures. Dehydration process around 365 K results in a conjugated 2D structure with weak interlayer connectivity. It was shown to be a reversible 3D to 2D framework transformation by a guest molecule, and rehydration of the dehydration product occurs at room temperature in saturated water vapor. Rehydrated complex exhibits lower dehydration temperature, due to decreased average crystalline size, with higher surface area resulting in easier release and diffusion of water during dehydration. Thermal degradation of dehydration around 570 K, results in loss of ethylene diamine, producing a related 2D layered polymer structure, without interconnectivity between individual polymer layers. - Highlights: • Reversible 3D to 2D framework topochemical transformation on dehydration around 365 K. • Resulting polymer exhibits 2D layered structure with weak interlayer connectivity. • Dehydration is fully reversible in saturated water vapor at room temperature. • Further degradation around 570 K yields 2D polymer without interlayer connectivity. • 2D polymer exhibits conjugated electronic system.

  17. Analytical modeling of mode selection and power control for underlay D2D communication in cellular networks

    KAUST Repository

    Elsawy, Hesham

    2014-11-01

    Device-to-device (D2D) communication enables the user equipments (UEs) located in close proximity to bypass the cellular base stations (BSs) and directly connect to each other, and thereby, offload traffic from the cellular infrastructure. D2D communication can improve spatial frequency reuse and energy efficiency in cellular networks. This paper presents a comprehensive and tractable analytical framework for D2D-enabled uplink cellular networks with a flexible mode selection scheme along with truncated channel inversion power control. The developed framework is used to analyze and understand how the underlaying D2D communication affects the cellular network performance. Through comprehensive numerical analysis, we investigate the expected performance gains and provide guidelines for selecting the network parameters.

  18. The global status of freshwater fish age validation studies and a prioritization framework for future research

    Science.gov (United States)

    Pope, Kevin L.; Hamel, Martin J.; Pegg, Mark A.; Spurgeon, Jonathan J.

    2016-01-01

    Age information derived from calcified structures is commonly used to estimate recruitment, growth, and mortality for fish populations. Validation of daily or annual marks on age structures is often assumed, presumably due to a lack of general knowledge concerning the status of age validation studies. Therefore, the current status of freshwater fish age validation studies was summarized to show where additional effort is needed, and increase the accessibility of validation studies to researchers. In total, 1351 original peer-reviewed articles were reviewed from freshwater systems that studied age in fish. Periodicity and age validation studies were found for 88 freshwater species comprising 21 fish families. The number of age validation studies has increased over the last 30 years following previous calls for more research; however, few species have validated structures spanning all life stages. In addition, few fishes of conservation concern have validated ageing structures. A prioritization framework, using a combination of eight characteristics, is offered to direct future age validation studies and close the validation information gap. Additional study, using the offered prioritization framework, and increased availability of published studies that incorporate uncertainty when presenting research results dealing with age information are needed.

  19. Validation of OPERA3D PCMI Analysis Code

    Energy Technology Data Exchange (ETDEWEB)

    Jeun, Ji Hoon; Choi, Jae Myung; Yoo, Jong Sung [KEPCO Nuclear Fuel Co., Daejeon (Korea, Republic of); Cheng, G.; Sim, K. S.; Chassie, Girma [Candu Energy INC.,Ontario (Canada)

    2013-10-15

    This report will describe introduction of validation of OPERA3D code, and validation results that are directly related with PCMI phenomena. OPERA3D was developed for the PCMI analysis and validated using the in-pile measurement data. Fuel centerline temperature and clad strain calculation results shows close expectations with measurement data. Moreover, 3D FEM fuel model of OPERA3D shows slight hour glassing behavior of fuel pellet in contact case. Further optimization will be conducted for future application of OPERA3D code. Nuclear power plant consists of many complicated systems, and one of the important objects of all the systems is maintaining nuclear fuel integrity. However, it is inevitable to experience PCMI (Pellet Cladding Mechanical Interaction) phenomena at current operating reactors and next generation reactors for advanced safety and economics as well. To evaluate PCMI behavior, many studies are on-going to develop 3-dimensional fuel performance evaluation codes. Moreover, these codes are essential to set the safety limits for the best estimated PCMI phenomena aimed for high burnup fuel.

  20. A 2.5D finite element and boundary element model for the ground vibration from trains in tunnels and validation using measurement data

    Science.gov (United States)

    Jin, Qiyun; Thompson, David J.; Lurcock, Daniel E. J.; Toward, Martin G. R.; Ntotsios, Evangelos

    2018-05-01

    A numerical model is presented for the ground-borne vibration produced by trains running in tunnels. The model makes use of the assumption that the geometry and material properties are invariant in the axial direction. It is based on the so-called two-and-a-half dimensional (2.5D) coupled Finite Element and Boundary Element methodology, in which a two-dimensional cross-section is discretised into finite elements and boundary elements and the third dimension is represented by a Fourier transform over wavenumbers. The model is applied to a particular case of a metro line built with a cast-iron tunnel lining. An equivalent continuous model of the tunnel is developed to allow it to be readily implemented in the 2.5D framework. The tunnel structure and the track are modelled using solid and beam finite elements while the ground is modelled using boundary elements. The 2.5D track-tunnel-ground model is coupled with a train consisting of several vehicles, which are represented by multi-body models. The response caused by the passage of a train is calculated as the sum of the dynamic component, excited by the combined rail and wheel roughness, and the quasi-static component, induced by the constant moving axle loads. Field measurements have been carried out to provide experimental validation of the model. These include measurements of the vibration of the rail, the tunnel invert and the tunnel wall. In addition, simultaneous measurements were made on the ground surface above the tunnel. Rail roughness and track characterisation measurements were also made. The prediction results are compared with measured vibration obtained during train passages, with good agreement.

  1. Development, validation and implementation of a quantitative food frequency questionnaire to assess habitual vitamin D intake.

    Science.gov (United States)

    Kiely, M; Collins, A; Lucey, A J; Andersen, R; Cashman, K D; Hennessy, Á

    2016-08-01

    A well-designed, validated quantitative food frequency questionnaire (FFQ) could offer an efficient and cost-effective method for assessing habitual vitamin D intake. The present study aimed to describe the development, validation and implementation of a vitamin D FFQ. National food consumption survey data obtained from Irish adults (18-64 years) were used to identify foods that contribute 95% of vitamin D intake. A winter-based validation study was carried out for the resulting FFQ in 120 females, including 98 women [mean (SD) 65.0 (7.3) years] and 22 girls [12.2 (0.8) years], using a 14-day diet history (DH) as a comparator. Serum 25(OH)D concentrations were analysed. Validity coefficients were calculated using the method of triads. Cross-classification and Bland-Altman analysis were also performed. Median (interquartile range) vitamin D intakes (including the contribution from nutritional supplements) were 5.4 (3.7) and 3.7 (5.9) μg day(-1) from the FFQ and DH, respectively and intakes of vitamin D from food sources were 3.6 (3.1) and 2.4 (2.2) μg day(-1) . The FFQ and DH classified 86% and 87% of individuals into the same and adjacent thirds of wintertime serum 25(OH)D status, respectively. There was a strong association (r = 0.71, P < 0.0001) and no significant systematic or proportional bias observed for the difference between estimates from the FFQ and DH. The validity coefficient for the FFQ was 0.92 (95% confidence interval = 0.80-0.97). Repeatability analysis (n = 56) performed 6-12 months later showed no significant difference in estimates of vitamin D between administrations. The data obtained in the present study indicate high validity and good reproducibility of a short, interviewer-administered FFQ for vitamin D. © 2016 The British Dietetic Association Ltd.

  2. “Stereoscopic” 2D super-microporous phosphazene-based covalent organic framework: Design, synthesis and selective sorption towards uranium at high acidic condition

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shuang; Zhao, Xiaosheng; Li, Bo; Bai, Chiyao; Li, Yang; Wang, Lei; Wen, Rui; Zhang, Meicheng; Ma, Lijian; Li, Shoujian, E-mail: sjli000616@scu.edu.cn

    2016-08-15

    Highlights: • Phosphorus element was first introduced into covalent organic frameworks (COFs). • Monomer in C{sub 3}-like spatial configuration was first used to construct COF materials. • A new 2D super-microporous phosphazene-based sorbent (MPCOF) was synthesized. • Separation of U (VI) by MPCOF at high acidic media (up to 1M HNO{sub 3}) was achieved. • Selectivity for U (VI) separation from multi-ion solution can reach unreported 92%. - Abstract: So far, only five primary elements (C, H, O, N and B) and two types of spatial configuration (C{sub 2}–C{sub 4}, C{sub 6} and T{sub d}) are reported to build the monomers for synthesis of covalent organic frameworks (COFs), which have partially limited the route selection for accessing COFs with new topological structure and novel properties. Here, we reported the design and synthesis of a new “stereoscopic” 2D super-microporous phosphazene-based covalent organic framework (MPCOF) by using hexachorocyclotriphosphazene (a P-containing monomer in a C{sub 3}-like spatial configuration) and p-phenylenediamine (a linker). The as-synthesized MPCOF shows high crystallinity, relatively high heat and acid stability and distinctive super-microporous structure with narrow pore-size distributions ranging from 1.0–2.1 nm. The results of batch sorption experiments with a multi-ion solution containing 12 co-existing cations show that in the pH range of 1–2.5, MPCOF exhibits excellent separation efficiency for uranium with adsorption capacity more than 71 mg/g and selectivity up to record-breaking 92%, and furthermore, an unreported sorption capacity (>50 mg/g) and selectivity (>60%) were obtained under strong acidic condition (1 M HNO{sub 3}). Studies on sorption mechanism indicate that the uranium separation by MPCOF in acidic solution is realized mainly through both intra-particle diffusion and size-sieving effect.

  3. Validating a Conceptual Framework for the Core Concept of ”Cell-cell Communication”

    Czech Academy of Sciences Publication Activity Database

    Michael, J.; Martinková, Patrícia; McFarland, J.L.; Wright, A.; Cliff, W.; Modell, H.; Wenderoth, M.P.

    2017-01-01

    Roč. 41, č. 2 (2017), s. 260-265 ISSN 1043-4046 R&D Projects: GA ČR GJ15-15856Y Institutional support: RVO:67985807 Keywords : conceptual framework * core concept * cell-cell communication * physiology Subject RIV: AM - Education OBOR OECD: Education , general; including training, pedagogy, didactics [and education systems] Impact factor: 1.755, year: 2016

  4. A Framework for Mixing Methods in Quantitative Measurement Development, Validation, and Revision: A Case Study

    Science.gov (United States)

    Luyt, Russell

    2012-01-01

    A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…

  5. Fit for purpose? Validation of a conceptual framework for personal recovery with current mental health consumers.

    Science.gov (United States)

    Bird, Victoria; Leamy, Mary; Tew, Jerry; Le Boutillier, Clair; Williams, Julie; Slade, Mike

    2014-07-01

    Mental health services in the UK, Australia and other Anglophone countries have moved towards supporting personal recovery as a primary orientation. To provide an empirically grounded foundation to identify and evaluate recovery-oriented interventions, we previously published a conceptual framework of personal recovery based on a systematic review and narrative synthesis of existing models. Our objective was to test the validity and relevance of this framework for people currently using mental health services. Seven focus groups were conducted with 48 current mental health consumers in three NHS trusts across England, as part of the REFOCUS Trial. Consumers were asked about the meaning and their experience of personal recovery. Deductive and inductive thematic analysis applying a constant comparison approach was used to analyse the data. The analysis aimed to explore the validity of the categories within the conceptual framework, and to highlight any areas of difference between the conceptual framework and the themes generated from new data collected from the focus groups. Both the inductive and deductive analysis broadly validated the conceptual framework, with the super-ordinate categories Connectedness, Hope and optimism, Identity, Meaning and purpose, and Empowerment (CHIME) evident in the analysis. Three areas of difference were, however, apparent in the inductive analysis. These included practical support; a greater emphasis on issues around diagnosis and medication; and scepticism surrounding recovery. This study suggests that the conceptual framework of personal recovery provides a defensible theoretical base for clinical and research purposes which is valid for use with current consumers. However, the three areas of difference further stress the individual nature of recovery and the need for an understanding of the population and context under investigation. © The Royal Australian and New Zealand College of Psychiatrists 2014.

  6. 2D to 3D conversion implemented in different hardware

    Science.gov (United States)

    Ramos-Diaz, Eduardo; Gonzalez-Huitron, Victor; Ponomaryov, Volodymyr I.; Hernandez-Fragoso, Araceli

    2015-02-01

    Conversion of available 2D data for release in 3D content is a hot topic for providers and for success of the 3D applications, in general. It naturally completely relies on virtual view synthesis of a second view given by original 2D video. Disparity map (DM) estimation is a central task in 3D generation but still follows a very difficult problem for rendering novel images precisely. There exist different approaches in DM reconstruction, among them manually and semiautomatic methods that can produce high quality DMs but they demonstrate hard time consuming and are computationally expensive. In this paper, several hardware implementations of designed frameworks for an automatic 3D color video generation based on 2D real video sequence are proposed. The novel framework includes simultaneous processing of stereo pairs using the following blocks: CIE L*a*b* color space conversions, stereo matching via pyramidal scheme, color segmentation by k-means on an a*b* color plane, and adaptive post-filtering, DM estimation using stereo matching between left and right images (or neighboring frames in a video), adaptive post-filtering, and finally, the anaglyph 3D scene generation. Novel technique has been implemented on DSP TMS320DM648, Matlab's Simulink module over a PC with Windows 7, and using graphic card (NVIDIA Quadro K2000) demonstrating that the proposed approach can be applied in real-time processing mode. The time values needed, mean Similarity Structural Index Measure (SSIM) and Bad Matching Pixels (B) values for different hardware implementations (GPU, Single CPU, and DSP) are exposed in this paper.

  7. Synchronized 2D/3D optical mapping for interactive exploration and real-time visualization of multi-function neurological images.

    Science.gov (United States)

    Zhang, Qi; Alexander, Murray; Ryner, Lawrence

    2013-01-01

    Efficient software with the ability to display multiple neurological image datasets simultaneously with full real-time interactivity is critical for brain disease diagnosis and image-guided planning. In this paper, we describe the creation and function of a new comprehensive software platform that integrates novel algorithms and functions for multiple medical image visualization, processing, and manipulation. We implement an opacity-adjustment algorithm to build 2D lookup tables for multiple slice image display and fusion, which achieves a better visual result than those of using VTK-based methods. We also develop a new real-time 2D and 3D data synchronization scheme for multi-function MR volume and slice image optical mapping and rendering simultaneously through using the same adjustment operation. All these methodologies are integrated into our software framework to provide users with an efficient tool for flexibly, intuitively, and rapidly exploring and analyzing the functional and anatomical MR neurological data. Finally, we validate our new techniques and software platform with visual analysis and task-specific user studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Validation of non-formal and informal learning from a European perspective – linking validation arrangements with national qualifications frameworks

    Directory of Open Access Journals (Sweden)

    Borut Mikulec

    2015-12-01

    Full Text Available The paper analyses European policy on the validation of non-formal and informal learning, which is presented as a “salvation narrative” that can improve the functioning of the labour market, provide a way out from unemployment and strengthen the competitiveness of the economy. Taking as our starting point recent findings in adult education theory on the validation of non-formal and informal learning, we aim to prove the thesis that what European validation policy promotes is above all economic purpose and that it establishes a “Credential/Credit-exchange” model of validation of non-formal and informal learning. We proceed to ecxamine the effect of European VNIL policy in selected European countries where validation arrangements are linked to the qualifications framework. We find that the “Credential/ Credit-exchange” validation model was first established in a few individual European countries and then transferred, as a “successful” model, to the level of common European VNIL policy.

  9. A framework for grand scale parallelization of the combined finite discrete element method in 2d

    Science.gov (United States)

    Lei, Z.; Rougier, E.; Knight, E. E.; Munjiza, A.

    2014-09-01

    Within the context of rock mechanics, the Combined Finite-Discrete Element Method (FDEM) has been applied to many complex industrial problems such as block caving, deep mining techniques (tunneling, pillar strength, etc.), rock blasting, seismic wave propagation, packing problems, dam stability, rock slope stability, rock mass strength characterization problems, etc. The reality is that most of these were accomplished in a 2D and/or single processor realm. In this work a hardware independent FDEM parallelization framework has been developed using the Virtual Parallel Machine for FDEM, (V-FDEM). With V-FDEM, a parallel FDEM software can be adapted to different parallel architecture systems ranging from just a few to thousands of cores.

  10. An end-to-end coupled model ROMS-N 2 P 2 Z 2 D 2 -OSMOSE of ...

    African Journals Online (AJOL)

    An end-to-end coupled model ROMS-N 2 P 2 Z 2 D 2 -OSMOSE of the southern Benguela foodweb: parameterisation, calibration and pattern-oriented validation. ... We also highlight the capacity of this model for tracking indicators at various hierarchical levels. Keywords: individual-based model, model validation, ...

  11. An interactive 3D framework for anatomical education

    OpenAIRE

    Vázquez Alcocer, Pere Pau; Götzelmann, Timo; Hartmann, Knut; Nürnberger, Andreas

    2008-01-01

    Object: This paper presents a 3D framework for Anatomy teaching. We are mainly concerned with the proper understanding of human anatomical 3D structures. Materials and methods: The main idea of our approach is taking an electronic book such as Henry Gray’s Anatomy of the human body, and a set of 3D models properly labeled, and constructing the correct linking that allows users to perform mutual searches between both media. Results: We implemented a system where learners can intera...

  12. Evaluating health inequity interventions: applying a contextual (external) validity framework to programs funded by the Canadian Health Services Research Foundation.

    Science.gov (United States)

    Phillips, Kaye; Müller-Clemm, Werner; Ysselstein, Margaretha; Sachs, Jonathan

    2013-02-01

    Including context in the measurement and evaluation of health in equity interventions is critical to understanding how events that occur in an intervention's environment might contribute to or impede its success. This study adapted and piloted a contextual validity assessment framework on a selection of health inequity-related programs funded by the Canadian Health Services Research Foundation (CHSRF) between 1998 and 2006. The two overarching objectives of this study were (1) to determine the relative amount and quality of attention given to conceptualizing, measuring and validating context within CHSRF funded research final reports related to health-inequity; and (2) to contribute evaluative evidence towards the incorporation of context into the assessment and measurement of health inequity interventions. The study found that of the 42/146 CHSRF programs and projects, judged to be related to health inequity 20 adequately reported on the conceptualization, measurement and validation of context. Amongst these health-inequity related project reports, greatest emphasis was placed on describing the socio-political and economical context over actually measuring and validating contextual evidence. Applying a contextual validity assessment framework was useful for distinguishing between the descriptive (conceptual) versus empirical (measurement and validation) inclusion of documented contextual evidence. Although contextual validity measurement frameworks needs further development, this study contributes insight into identifying funded research related to health inequities and preliminary criteria for assessing interventions targeted at specific populations and jurisdictions. This study also feeds a larger critical dialogue (albeit beyond the scope of this study) regarding the relevance and utility of using evaluative techniques for understanding how specific external conditions support or impede the successful implementation of health inequity interventions. Copyright

  13. Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation.

    Science.gov (United States)

    Mekkaoui, Choukri; Huang, Shuning; Chen, Howard H; Dai, Guangping; Reese, Timothy G; Kostis, William J; Thiagalingam, Aravinda; Maurovich-Horvat, Pal; Ruskin, Jeremy N; Hoffmann, Udo; Jackowski, Marcel P; Sosnovik, David E

    2012-10-12

    The study of myofiber reorganization in the remote zone after myocardial infarction has been performed in 2D. Microstructural reorganization in remodeled hearts, however, can only be fully appreciated by considering myofibers as continuous 3D entities. The aim of this study was therefore to develop a technique for quantitative 3D diffusion CMR tractography of the heart, and to apply this method to quantify fiber architecture in the remote zone of remodeled hearts. Diffusion Tensor CMR of normal human, sheep, and rat hearts, as well as infarcted sheep hearts was performed ex vivo. Fiber tracts were generated with a fourth-order Runge-Kutta integration technique and classified statistically by the median, mean, maximum, or minimum helix angle (HA) along the tract. An index of tract coherence was derived from the relationship between these HA statistics. Histological validation was performed using phase-contrast microscopy. In normal hearts, the subendocardial and subepicardial myofibers had a positive and negative HA, respectively, forming a symmetric distribution around the midmyocardium. However, in the remote zone of the infarcted hearts, a significant positive shift in HA was observed. The ratio between negative and positive HA variance was reduced from 0.96 ± 0.16 in normal hearts to 0.22 ± 0.08 in the remote zone of the remodeled hearts (p layers of the myocardium. Tractography-based quantification, performed here for the first time in remodeled hearts, may provide a framework for assessing regional changes in the left ventricle following infarction.

  14. The 2-D lattice theory of Flower Constellations

    Science.gov (United States)

    Avendaño, Martín E.; Davis, Jeremy J.; Mortari, Daniele

    2013-08-01

    The 2-D lattice theory of Flower Constellations, generalizing Harmonic Flower Constellations (the symmetric subset of Flower Constellations) as well as the Walker/ Mozhaev constellations, is presented here. This theory is a new general framework to design symmetric constellations using a 2× 2 lattice matrix of integers or by its minimal representation, the Hermite normal form. From a geometrical point of view, the phasing of satellites is represented by a regular pattern (lattice) on a two-Dimensional torus. The 2-D lattice theory of Flower Constellations does not require any compatibility condition and uses a minimum set of integer parameters whose meaning are explored throughout the paper. This general minimum-parametrization framework allows us to obtain all symmetric distribution of satellites. Due to the J_2 effect this design framework is meant for circular orbits and for elliptical orbits at critical inclination, or to design elliptical constellations for the unperturbed Keplerian case.

  15. [Adaptation and validation of the SMP-T2D questionnaire in Spanish for evaluating self-management of high blood pressure and type 2 diabetes: PAG-DT2+HTA].

    Science.gov (United States)

    Galván Flores, G M; Gallegos Carrillo, K; Palomo Piñon, S; Sánchez García, S; Cuadros Moreno, J; Martínez Olivares, M V; Cuevas Cancino, J J; Grijalva, I; Sánchez Arenas, R

    High blood pressure is one of the most common chronic conditions worldwide. It affects one in every 3 adults over 40, while one in 10 suffers from diabetes. For both diseases, adherence to pharmacological treatment is over 30%, and self-management, which takes into account diet and physical activity, is still unknown, as there is no tool available to measure self-management. Therefore, the object of this study was to adapt and validate the Spanish version of the self-management profile for type 2 diabetes (SMP-T2D) questionnaire in patients with type 2 diabetes and high blood pressure among users of first level care in the social security institution of Mexico. The SMP-T2D was adapted to Spanish by translation into Spanish, and being used only in patients with high blood pressure and type 2 diabetes-hypertension. A convergent and discriminatory validation was performed. Patients over 50 years old with high blood pressure were include. Those that did not complete the questionnaire or give informed consent were rejected. The Spanish version of the SMP-T2D was called PAG-DT2+HTA, and was applied to 145 people with hypertension: 54.4% with hypertension only, and 43.6% with hypertension and type 2 diabetes. Mean age was 66.14 years (SD=10.78), with 34.7% women and 65.3% men. Internal consistency by α-Cronbach for the questionnaire was 0.561 (P=.000). The correlation between the PAG-DT2+HTA and Morisky-Green was significant. The ability to discriminate between people with and without education and with and without economic means was obtained. The Spanish version of SMP-T2D (PAG-DT2+HTA) that measures self-management in type 2 diabetes, can be used to measure self-management in people with type 2 diabetes-hypertension. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Four new 3D metal-organic frameworks constructed by the asymmetrical pentacarboxylate: gas sorption behaviour and magnetic properties.

    Science.gov (United States)

    Yan, Yang-Tian; Zhang, Wen-Yan; Wu, Yun-Long; Li, Jiang; Xi, Zheng-Ping; Wang, Yao-Yu; Hou, Lei

    2016-10-04

    By using an asymmetrical rigid pentacarboxylic acid ligand, 2,4-di(3',5'-dicarboxylphenyl)benzoic acid (H 5 L), four new three-dimensional (3D) metal-organic frameworks (MOFs), namely {[Cu 2 (HL)(H 2 O) 22DMF·2H 2 O} n (1), {[Co 2 (L)(DMA)]·H 2 N(Me) 2 } n (2), {[Co 2 (L)(H 2 O)]·H 2 N(Me) 2 } n (3), {[Mn 2 (L)(DMF)(H 2 O)]·H 2 N(Me) 2 } n (4), were solvothermally synthesized. H 5 L in 1-4 shows different coordination modes and can easily form various metal clusters (secondary building units, SBUs) in the final structures. 1 is a 3D porous framework with a (4,4)-connected pts topology based on the [Cu 2 (COO) 4 ] paddlewheel SBU, wherein six SBUs are connected by twelve HL 4- to get an unprecedented Cu 12 hendecahedron nanocage. 2-4 possess similar dinuclear [M 2 (COO) 5 ] SBUs (M = Co, Mn), which are further extended by L 5- to give rise to 3D frameworks with the uncommon (5,5)-connected nia-5,5-P2 1 /c and bnn topologies. In addition, the desolvated framework of 1 contains polar channels decorated with uncoordinated carboxylate groups, leading to selective adsorption for CO 2 over CH 4 at 195, 273 and 298 K. Moreover, the magnetic properties of 1-4 show that there exist antiferromagnetic interactions between metal ions.

  17. 3D Oxidized Graphene Frameworks: An Efficient Adsorbent for Methylene Blue

    Science.gov (United States)

    Pandey, Abhishek; Deb, Madhurima; Tiwari, Shreya; Pawar, Pranav Bhagwan; Saxena, Sumit; Shukla, Shobha

    2018-04-01

    Extraordinary properties of graphene and its derivatives have found application in varied areas such as energy, electronics, optical devices and sensors, to name a few. Large surface area along with specialized functional groups make these materials attractive for removal of dye molecules in solution via adsorption. Industrial effluents contain large amounts of toxic chemicals resulting in pollution of water bodies, which pose environmental hazards in general. Here we report application of 3D oxidized graphene frameworks in the efficient removal of cationic dye molecules such as methylene blue via adsorption. Systematic parametric studies investigating the effect of the initial dye concentration, pH and contact time have been performed. Spectroscopic analysis of the filtrate suggests that tortuous paths in 3D oxidized graphene frameworks result in efficient removal of dye molecules due to enhanced interaction. The hydroxyl groups retained in these 3D oxidized graphene frameworks facilitate adsorption of the dye molecules while passing through the adsorbent. pH studies suggest that maximum removal efficiency for methylene blue was achieved at pH value of 9. The results suggest that these 3D oxidized graphene frameworks can be used for purification of large volumes of contaminated water from cationic dyes in waste water treatment plants.

  18. Solvent-free porous framework resulted from 3D entanglement of 1D zigzag coordination polymer

    KAUST Repository

    Kole, Goutam Kumar Umar; Cairns, Amy J.; Eddaoudi, Mohamed; Vittal, Jagadese J.

    2010-01-01

    A solvent-free porous metal organic framework is constructed by the 3D entanglement of 1D zigzag coordination polymeric chains. The role of solvents and the effect of reaction conditions on such unique entanglement are addressed. © 2010 The Royal

  19. An ice sheet model validation framework for the Greenland ice sheet

    Science.gov (United States)

    Price, Stephen F.; Hoffman, Matthew J.; Bonin, Jennifer A.; Howat, Ian M.; Neumann, Thomas; Saba, Jack; Tezaur, Irina; Guerber, Jeffrey; Chambers, Don P.; Evans, Katherine J.; Kennedy, Joseph H.; Lenaerts, Jan; Lipscomb, William H.; Perego, Mauro; Salinger, Andrew G.; Tuminaro, Raymond S.; van den Broeke, Michiel R.; Nowicki, Sophie M. J.

    2017-01-01

    We propose a new ice sheet model validation framework - the Cryospheric Model Comparison Tool (CmCt) - that takes advantage of ice sheet altimetry and gravimetry observations collected over the past several decades and is applied here to modeling of the Greenland ice sheet. We use realistic simulations performed with the Community Ice Sheet Model (CISM) along with two idealized, non-dynamic models to demonstrate the framework and its use. Dynamic simulations with CISM are forced from 1991 to 2013, using combinations of reanalysis-based surface mass balance and observations of outlet glacier flux change. We propose and demonstrate qualitative and quantitative metrics for use in evaluating the different model simulations against the observations. We find that the altimetry observations used here are largely ambiguous in terms of their ability to distinguish one simulation from another. Based on basin-scale and whole-ice-sheet-scale metrics, we find that simulations using both idealized conceptual models and dynamic, numerical models provide an equally reasonable representation of the ice sheet surface (mean elevation differences of framework demonstrates that our proposed metrics can distinguish relatively better from relatively worse simulations and that dynamic ice sheet models, when appropriately initialized and forced with the right boundary conditions, demonstrate a predictive skill with respect to observed dynamic changes that have occurred on Greenland over the past few decades. An extensible design will allow for continued use of the CmCt as future altimetry, gravimetry, and other remotely sensed data become available for use in ice sheet model validation.

  20. Vitamin D status assessed by a validated HPLC method: within and between variation in subjects supplemented with vitamin D3

    DEFF Research Database (Denmark)

    Jakobsen, Jette; Bysted, Anette; Andersen, Rikke

    2009-01-01

    Objective. The aim of this study was to develop and validate a high-pressure liquid chromatography (HPLC) method for assessing vitamin D status as 25-hydroxyvitamin D2 (S-25OHD2) and 25-hydroxyvitamin D3 (S-25OHD3) in serum. Material and methods. We assessed the within- and between-subject variat......Objective. The aim of this study was to develop and validate a high-pressure liquid chromatography (HPLC) method for assessing vitamin D status as 25-hydroxyvitamin D2 (S-25OHD2) and 25-hydroxyvitamin D3 (S-25OHD3) in serum. Material and methods. We assessed the within- and between......-subject variation of vitamin D status in serum samples from four different dietary intervention studies in which subjects (n=92) were supplemented with different doses of vitamin D3 (5-12 g/day) and for different durations (4-20 months). Results. The HPLC method was applicable for 4.0-200 nmol S-25OHD/L, while...... the within-day and between-days variations were 3.8 % and 5.7 %, respectively. There was a concentration-dependent difference between results obtained by a commercial radioimmunoassay and results from the HPLC method of -5 to 20 nmol 25OHD/L in the range 10-100 nmol 25OHD/L. The between-subject variation...

  1. A novel cryogenic magnetic refrigerant metal-organic framework based on 1D gadolinium(III) chain

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Qun; Li, Peng-Fei [Guangxi Key Laboratory of Electrochemical and Magneto-chemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, Guangxi 541004 (China); Zou, Zhi-Ming, E-mail: 2014005@glut.edu.cn [Guangxi Key Laboratory of Electrochemical and Magneto-chemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, Guangxi 541004 (China); Liu, Zheng [Guangxi Key Laboratory of Electrochemical and Magneto-chemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, Guangxi 541004 (China); Liu, Shu-Xia, E-mail: liusx@nenu.edu.cn [Key Laboratory of Polyoxometalate Science of Ministry of Education, College of Chemistry, Northeast Normal University, Changchun, Jilin 130024 (China)

    2017-02-15

    A metal-organic framework (MOF) based on gadolinium ion (Gd{sup 3+}) and tricarboxylate ligand, [Gd(BTPCA)(H{sub 2}O)]·2DMF·3H{sub 2}O (Gd-BTPCA) (H{sub 3}BTPCA =1,1′,1′-(benzene-1,3,5-triyl)tripiperidine-4-carboxylic acid; DMF=dimethylformamide), was synthesized and structurally characterized. The adjacent Gd{sup 3+} ions are intraconnected by the carboxylate groups of the BTPCA{sup 3-} ligands to form a 1D Gd{sup 3+} ion chain. The 1D Gd{sup 3+} ion chains are interconnected by the BTPCA{sup 3-} ligands, giving rise to a 3D framework with 1D open channel. The magnetic studies indicate that Gd-BTPCA exhibits weak ferromagnetic interactions, and acts as a cryogenic magnetic refrigerant having the magnetic entropy change (−ΔS{sub m}) of 20.40 J kg{sup −1} K{sup −1} for ΔH =7 T at 3 K. - Graphical abstract: A 1D gadolinium(III) chains-based metal-organic framework performed ferromagnetic coupling on the magnetic property. Magnetic investigation reveals that Gd-BTPCA exhibits the entropy change (−ΔS{sub m}) of 20.40 J kg{sup −1} K{sup −1} for ΔH =7 T at 3 K. - Highlights: • The MOF based on gadolinium ion and tricarboxylate ligand was synthesized. • This MOF is connected with 1D Gd{sup 3+} ions chain and the carboxylate groups of BTPCA{sup 3-} ligands. • The magnetic studies indicate that the MOF exhibits the weak ferromagnetic interactions. • Magnetic investigation reveals that the MOF exhibits the high entropy change.

  2. Validity of instruments to measure physical activity may be questionable due to a lack of conceptual frameworks: a systematic review

    Science.gov (United States)

    2011-01-01

    Background Guidance documents for the development and validation of patient-reported outcomes (PROs) advise the use of conceptual frameworks, which outline the structure of the concept that a PRO aims to measure. It is unknown whether currently available PROs are based on conceptual frameworks. This study, which was limited to a specific case, had the following aims: (i) to identify conceptual frameworks of physical activity in chronic respiratory patients or similar populations (chronic heart disease patients or the elderly) and (ii) to assess whether the development and validation of PROs to measure physical activity in these populations were based on a conceptual framework of physical activity. Methods Two systematic reviews were conducted through searches of the Medline, Embase, PsycINFO, and Cinahl databases prior to January 2010. Results In the first review, only 2 out of 581 references pertaining to physical activity in the defined populations provided a conceptual framework of physical activity in COPD patients. In the second review, out of 103 studies developing PROs to measure physical activity or related constructs, none were based on a conceptual framework of physical activity. Conclusions These findings raise concerns about how the large body of evidence from studies that use physical activity PRO instruments should be evaluated by health care providers, guideline developers, and regulatory agencies. PMID:21967887

  3. An MGF-based unified framework to determine the joint statistics of partial sums of ordered i.n.d. random variables

    KAUST Repository

    Nam, Sungsik

    2014-08-01

    The joint statistics of partial sums of ordered random variables (RVs) are often needed for the accurate performance characterization of a wide variety of wireless communication systems. A unified analytical framework to determine the joint statistics of partial sums of ordered independent and identically distributed (i.i.d.) random variables was recently presented. However, the identical distribution assumption may not be valid in several real-world applications. With this motivation in mind, we consider in this paper the more general case in which the random variables are independent but not necessarily identically distributed (i.n.d.). More specifically, we extend the previous analysis and introduce a new more general unified analytical framework to determine the joint statistics of partial sums of ordered i.n.d. RVs. Our mathematical formalism is illustrated with an application on the exact performance analysis of the capture probability of generalized selection combining (GSC)-based RAKE receivers operating over frequency-selective fading channels with a non-uniform power delay profile. © 1991-2012 IEEE.

  4. An unprecedented extended architecture constructed from a 2-D interpenetrating cationic coordination framework templated by SiW12O404- anion

    International Nuclear Information System (INIS)

    Wang Xiuli; Lin Hongyan; Bi Yanfeng; Chen Baokuan; Liu Guocheng

    2008-01-01

    A novel inorganic-organic hybrid compound based on polyoxometalates (POMs) and organic ligand formulated as [Cu 2 (bpp) 4 (H 2 O) 2 ](SiW 12 O 40 )∼6H 2 O (1) [bpp=1,3-bis(4-pyridyl)propane], was hydrothermally synthesized and structurally characterized by elemental analysis, single-crystal X-ray diffraction analysis, IR, TG, and cyclic voltammetry. Crystal data for 1: Orthorhombic, Pbcn, a=23.0085(19) A, b=14.6379(12) A, c=23.6226(19) A, V=7956.0(11) A 3 , Z=4, Dc=3.315 g cm -3 , and R(final)=0.0826. X-ray diffraction study reveals that compound 1 was the first interpenetrating network of 2-D metal-organic cationic coordination framework [Cu 2 (bpp) 4 (H 2 O) 2 ] n 4n+ , in which Keggin-type anions SiW 12 O 40 4- has been used as a non-coordinating anionic template. The electrochemical property of 1-bulk modified carbon paste electrode (1-CPE) has been studied, and the results indicate that 1-CPE has good electrocatalytic activities toward the reduction of nitrite in 1 M H 2 SO 4 aqueous solution. - Graphical abstract: Compound [Cu 2 (bpp) 4 (H 2 O) 2 ](SiW 12 O 40 )∼6H 2 O (1) represents the first 2-D interpenetrating cationic metal-organic frameworks (MOFs) templated by Keggin-type anions. These MOF layers are stacked together along the crystallographic c axis exactly to construct large cubic-like channels (with dimensions of 12.3x13.6 A) occupied by SiW 12 O 40 4- clusters

  5. Validation of an e-Learning 3.0 Critical Success Factors Framework: A Qualitative Research

    OpenAIRE

    Paula Miranda; Pedro Isaias; Carlos J Costa; Sara Pifano

    2017-01-01

    Aim/Purpose: As e-Learning 3.0 evolves from a theoretical construct into an actual solution for online learning, it becomes crucial to accompany this progress by scrutinising the elements that are at the origin of its success. Background: This paper outlines a framework of e-Learning 3.0’s critical success factors and its empirical validation. Methodology: The framework is the result of an extensive literature review and its empirical substantiation derives from semi-structured inte...

  6. 2D and 3D CT Radiomics Features Prognostic Performance Comparison in Non-Small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Chen Shen

    2017-12-01

    Full Text Available OBJECTIVE: To compare 2D and 3D radiomics features prognostic performance differences in CT images of non-small cell lung cancer (NSCLC. METHOD: We enrolled 588 NSCLC patients from three independent cohorts. Two sets of 463 patients from two different institutes were used as the training cohort. The remaining cohort with 125 patients was set as the validation cohort. A total of 1014 radiomics features (507 2D features and 507 3D features correspondingly were assessed. Based on the dichotomized survival data, 2D and 3D radiomics indicators were calculated for each patient by trained classifiers. We used the area under the receiver operating characteristic curve (AUC to assess the prediction performance of trained classifiers (the support vector machine and logistic regression. Kaplan–Meier and Cox hazard survival analyses were also employed. Harrell's concordance index (C-Index and Akaike's information criteria (AIC were applied to assess the trained models. RESULTS: Radiomics indicators were built and compared by AUCs. In the training cohort, 2D_AUC = 0.653, 3D_AUC = 0.671. In the validation cohort, 2D_AUC = 0.755, 3D_AUC = 0.663. Both 2D and 3D trained indicators achieved significant results (P < .05 in the Kaplan-Meier analysis and Cox regression. In the validation cohort, 2D Cox model had a C-Index = 0.683 and AIC = 789.047; 3D Cox model obtained a C-Index = 0.632 and AIC = 799.409. CONCLUSION: Both 2D and 3D CT radiomics features have a certain prognostic ability in NSCLC, but 2D features showed better performance in our tests. Considering the cost of the radiomics features calculation, 2D features are more recommended for use in the current study.

  7. A Framework for Low-Communication 1-D FFT

    Directory of Open Access Journals (Sweden)

    Ping Tak Peter Tang

    2013-01-01

    Full Text Available In high-performance computing on distributed-memory systems, communication often represents a significant part of the overall execution time. The relative cost of communication will certainly continue to rise as compute-density growth follows the current technology and industry trends. Design of lower-communication alternatives to fundamental computational algorithms has become an important field of research. For distributed 1-D FFT, communication cost has hitherto remained high as all industry-standard implementations perform three all-to-all internode data exchanges (also called global transposes. These communication steps indeed dominate execution time. In this paper, we present a mathematical framework from which many single-all-to-all and easy-to-implement 1-D FFT algorithms can be derived. For large-scale problems, our implementation can be twice as fast as leading FFT libraries on state-of-the-art computer clusters. Moreover, our framework allows tradeoff between accuracy and performance, further boosting performance if reduced accuracy is acceptable.

  8. A framework for an on-line diagnostic expert system with intelligent sensor validation

    International Nuclear Information System (INIS)

    Kim, Young Jin

    1997-01-01

    This paper outlines a framework for performing two different but inter-related functions in diagnosis, i.e. sensor validation and reasoning under uncertainty. Sensor validation plays a vital role in the ability of the overall system to correctly determine the state of a plant monitored by imperfect sensors (Sopocy, 1990). Two subsystems, Algorithmic(ASV) and Heuristic(HSV) Sensor Validation, separate activities according to the degree of plant knowledge required and represent Sensor Validation Expert System when combined. Uncertain information in sensory values is represented through probability assignments on three discrete states, High, Normal, and Low, and additional sensor confidence measures in ASV. HSV exploits deeper knowledge about parameter interaction within the plant to cull sensor faults from the data stream. Finally the modified probability distributions and validated data are used as input to the reasoning scheme which is the run-time version of the influence diagram. The influence diagram represents the backbone of reasoning under uncertainty in Influence Diagram Knowledge Base. (author)

  9. Validation of the Turkish version of the Centre for Epidemiologic Studies Depression Scale (CES-D) in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Lehmann, Vicky; Makine, Ceylan; Karşıdağ, Cagatay

    2011-01-01

    BACKGROUND: Depression is a common co-morbid health problem in patients with diabetes that is underrecognised. Current international guidelines recommend screening for depression in patients with diabetes. Yet, few depression screening instruments have been validated for use in this particular......-D, the World Health Organization-Five Well-Being Index (WHO-5), and the Problem Areas in Diabetes scale (PAID). Explanatory factor analyses, various correlations and Cronbach's alpha were investigated to test the validity and reliability of the CES-D in Turkish diabetes outpatients. RESULTS: The original four...... of the total score was high (0.88), as were split-half coefficients (0.77-0.90). The correlation of the CES-D with the WHO-5 was the strongest (r = -0.70), and supported concurrent validity. CONCLUSION: The CES-D appears to be a valid measure for the assessment of depression in Turkish diabetes patients...

  10. High nitrogen-containing cotton derived 3D porous carbon frameworks for high-performance supercapacitors

    Science.gov (United States)

    Fan, Li-Zhen; Chen, Tian-Tian; Song, Wei-Li; Li, Xiaogang; Zhang, Shichao

    2015-01-01

    Supercapacitors fabricated by 3D porous carbon frameworks, such as graphene- and carbon nanotube (CNT)-based aerogels, have been highly attractive due to their various advantages. However, their high cost along with insufficient yield has inhibited their large-scale applications. Here we have demonstrated a facile and easily scalable approach for large-scale preparing novel 3D nitrogen-containing porous carbon frameworks using ultralow-cost commercial cotton. Electrochemical performance suggests that the optimal nitrogen-containing cotton-derived carbon frameworks with a high nitrogen content (12.1 mol%) along with low surface area 285 m2 g−1 present high specific capacities of the 308 and 200 F g−1 in KOH electrolyte at current densities of 0.1 and 10 A g−1, respectively, with very limited capacitance loss upon 10,000 cycles in both aqueous and gel electrolytes. Moreover, the electrode exhibits the highest capacitance up to 220 F g−1 at 0.1 A g−1 and excellent flexibility (with negligible capacitance loss under different bending angles) in the polyvinyl alcohol/KOH gel electrolyte. The observed excellent performance competes well with that found in the electrodes of similar 3D frameworks formed by graphene or CNTs. Therefore, the ultralow-cost and simply strategy here demonstrates great potential for scalable producing high-performance carbon-based supercapacitors in the industry. PMID:26472144

  11. High nitrogen-containing cotton derived 3D porous carbon frameworks for high-performance supercapacitors

    Science.gov (United States)

    Fan, Li-Zhen; Chen, Tian-Tian; Song, Wei-Li; Li, Xiaogang; Zhang, Shichao

    2015-10-01

    Supercapacitors fabricated by 3D porous carbon frameworks, such as graphene- and carbon nanotube (CNT)-based aerogels, have been highly attractive due to their various advantages. However, their high cost along with insufficient yield has inhibited their large-scale applications. Here we have demonstrated a facile and easily scalable approach for large-scale preparing novel 3D nitrogen-containing porous carbon frameworks using ultralow-cost commercial cotton. Electrochemical performance suggests that the optimal nitrogen-containing cotton-derived carbon frameworks with a high nitrogen content (12.1 mol%) along with low surface area 285 m2 g-1 present high specific capacities of the 308 and 200 F g-1 in KOH electrolyte at current densities of 0.1 and 10 A g-1, respectively, with very limited capacitance loss upon 10,000 cycles in both aqueous and gel electrolytes. Moreover, the electrode exhibits the highest capacitance up to 220 F g-1 at 0.1 A g-1 and excellent flexibility (with negligible capacitance loss under different bending angles) in the polyvinyl alcohol/KOH gel electrolyte. The observed excellent performance competes well with that found in the electrodes of similar 3D frameworks formed by graphene or CNTs. Therefore, the ultralow-cost and simply strategy here demonstrates great potential for scalable producing high-performance carbon-based supercapacitors in the industry.

  12. Facile fabrication of a novel 3D graphene framework/Bi nanoparticle film for ultrasensitive electrochemical assays of heavy metal ions

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Lei [State Key Laboratory of Lake Science and Environment, Nanjing Institute of Geography and Limnology, Chinese Academy of Sciences, Nanjing 210008 (China); Li, Yangyang; Rong, Xiaojiao [School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Wang, Yan [State Key Laboratory of Lake Science and Environment, Nanjing Institute of Geography and Limnology, Chinese Academy of Sciences, Nanjing 210008 (China); Ding, Shiming, E-mail: smding@niglas.ac.cn [State Key Laboratory of Lake Science and Environment, Nanjing Institute of Geography and Limnology, Chinese Academy of Sciences, Nanjing 210008 (China)

    2017-05-22

    In this work, a novel 3D graphene framework/Bi nanoparticle (GF/BiNP) film was fabricated with a facile preparation route. 3D graphene framework with porous structures was electrochemically reduced and in situ assembled on the electrode, and BiNPs with tunable morphologies were highly dispersed on the framework by a chemical reduction. Newly-designed 3D GF/BiNP film possessed a significantly large active area, fast electron transfer ability, high mass transfer efficiency, and excellent structure stability and binding strength on electrode. To demonstrate its superior ability, electrochemical sensors for the assay of heavy metal ions were constructed. As a result, a simultaneous assay of Pb{sup 2+} and Cd{sup 2+} with ultralow detection limits (0.02 μg L{sup −1} of Pb{sup 2+} and 0.05 μg L{sup −1} of Cd{sup 2+}, S/N = 3) and a wide linear range from 1 to 120 μg L{sup −1} was achieved. Meanwhile, a separate analysis of Zn{sup 2+} was performed to get optimum responses, in which a low detection limit of 4.0 μg L{sup −1} (S/N = 3) with a linear range from 40 to 300 μg L{sup −1} was observed, confirming the versatility of the GF/BiNP film in the detection of heavy metal ions. Moreover, excellent repeatability, reproducibility and stability, and reliable assays in real water samples were realized with constructed sensors. Due to its convenient preparation, favorable structures and excellent properties, prepared 3D GF/BiNP film will find great potential for advanced applications in environment, biomedicine and energy systems. - Highlights: • A novel 3D graphene framework/Bi nanoparticle (GF/BiNP) film is prepared. • Porous graphene framework is in situ assembled on the electrode. • BiNPs with tunable morphologies are highly dispersed on the framework. • Newly-designed 3D GF/BiNP film possesses excellent properties. • Sensitive electrochemical sensors for Pb{sup 2+}, Cd{sup 2+} and Zn{sup 2+} are constructed.

  13. Validating the Type D personality construct in Chinese patients with coronary heart disease.

    Science.gov (United States)

    Yu, Doris S F; Thompson, David R; Yu, Cheuk Man; Pedersen, Susanne S; Denollet, Johan

    2010-08-01

    Type D personality predicts poor prognosis in coronary heart disease (CHD) but little is known about Type D in non-Western cultures. We examined the (a) validity of the Type D construct and its assessment with the DS14 scale in the Chinese culture, (b) prevalence of Type D, and (c) gender vs. Type D discrepancies in depression/anxiety, among Chinese patients with CHD. Patients with CHD (N=326) completed the Chinese version of the DS14. The NEO Five Factor Inventory (NEO-FFI), Hospital Anxiety and Depression Scale (HADS), and Stress Symptom Checklist (SSC) were administered to subsamples to establish construct and discriminant validity. Administration of the DS14, HADS, and SSC was repeated at 1 month after hospital discharge in 66 patients, and stability of the DS14 was examined in another subsample of 100 patients. The theoretical structure of the Type D construct in the Chinese culture was supported (chi(2)/df=2.89, root mean square error of approximation=0.08, normal fit index=0.91, non-normal fit index=0.91, comparative fit index=0.93). The Negative Affectivity (NA) and Social Inhibition (SI) subscales of the DS14 in the entire sample were internally consistent (Cronbach's alpha=0.89/0.81), measured stable traits (3-month test-retest ICC=0.76/0.74), and correlated significantly with the neuroticism (NA/neuroticism, r=0.78, Ppersonality was 31%. Type D was not related to transient emotional states. However, Chinese patients with a Type D personality were at increased concurrent risk of anxiety (P=.002) and depression (P=.016). Type D personality is a cross-culturally valid construct, is associated with an increased risk of anxiety and depression, and deserves prompt attention in estimating the prognostic risk of Chinese CHD patients. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Solvent-free porous framework resulted from 3D entanglement of 1D zigzag coordination polymer

    KAUST Repository

    Kole, Goutam Kumar Umar

    2010-01-01

    A solvent-free porous metal organic framework is constructed by the 3D entanglement of 1D zigzag coordination polymeric chains. The role of solvents and the effect of reaction conditions on such unique entanglement are addressed. © 2010 The Royal Society of Chemistry and the Centre National de la Recherche Scientifique.

  15. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, Mirabela, E-mail: mirabela.rusu@gmail.com; Wang, Haibo; Madabhushi, Anant [Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Golden, Thea; Gow, Andrew [Department of Pharmacology and Toxicology, Rutgers University, Piscataway, New Jersey 08854 (United States)

    2015-08-15

    inflammation in a mouse model. The authors’ evaluation considered three mice, two with an inflammation phenotype and one control. The authors’ iterative 3D histology reconstruction yielded a 70.1% ± 2.7% overlap with the ex vivo MRI volume. Across a total of 17 anatomic landmarks manually delineated at the division of airways, the target registration error between the ex vivo MRI and 3D histology reconstruction was 0.85 ± 0.44 mm, suggesting that a good alignment of the ex vivo 3D histology and ex vivo MRI had been achieved. The 3D histology-in vivo MRI coregistered volumes resulted in an overlap of 73.7% ± 0.9%. Preliminary computerized feature analysis was performed on an additional four control mice, for a total of seven mice considered in this study. Gabor texture filters appeared to best capture differences between the inflamed and noninflamed regions on MRI. Conclusions: The authors’ 3D histology reconstruction and multimodal registration framework were successfully employed to reconstruct the histology volume of the lung and fuse it with in vivo MRI to create a ground truth map for inflammation on in vivo MRI. The analytic platform presented here lays the framework for a rigorous validation of the identified imaging features for chronic lung inflammation on MRI in a large prospective cohort.

  16. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

    International Nuclear Information System (INIS)

    Rusu, Mirabela; Wang, Haibo; Madabhushi, Anant; Golden, Thea; Gow, Andrew

    2015-01-01

    inflammation in a mouse model. The authors’ evaluation considered three mice, two with an inflammation phenotype and one control. The authors’ iterative 3D histology reconstruction yielded a 70.1% ± 2.7% overlap with the ex vivo MRI volume. Across a total of 17 anatomic landmarks manually delineated at the division of airways, the target registration error between the ex vivo MRI and 3D histology reconstruction was 0.85 ± 0.44 mm, suggesting that a good alignment of the ex vivo 3D histology and ex vivo MRI had been achieved. The 3D histology-in vivo MRI coregistered volumes resulted in an overlap of 73.7% ± 0.9%. Preliminary computerized feature analysis was performed on an additional four control mice, for a total of seven mice considered in this study. Gabor texture filters appeared to best capture differences between the inflamed and noninflamed regions on MRI. Conclusions: The authors’ 3D histology reconstruction and multimodal registration framework were successfully employed to reconstruct the histology volume of the lung and fuse it with in vivo MRI to create a ground truth map for inflammation on in vivo MRI. The analytic platform presented here lays the framework for a rigorous validation of the identified imaging features for chronic lung inflammation on MRI in a large prospective cohort

  17. Ionothermal Synthesis of a Novel 3D Cobalt Coordination Polymer with a Uniquely Reported Framework: [BMI]2[Co2(BTC2(H2O2

    Directory of Open Access Journals (Sweden)

    Il-Ju Ko

    2017-01-01

    Full Text Available The framework of [RMI]2[Co2(BTC2(H2O2] (RMI = 1-alkyl-3-methylimidazolium, alkyl; ethyl (EMI; propyl (PMI; butyl (BMI, which has uniquely occurred in ionothermal reactions of metal salts and H3BTC (1,3,5-benzenetricarboxylic acid, an organic ligand, reappeared in this work. Ionothermal reaction of cobalt acetate and H3BTC with [BMI]Br ionic liquid as the reaction medium yielded the novel coordination polymer [BMI]2[Co2(BTC2(H2O2] (compound B2. Similar ionothermal reactions with different [EMI]Br and [PMI]Br as the reaction media have been previously reported to produce [EMI]2[Co3(BTC2(OAc2] (compound A1 and [PMI]2[Co2(BTC2(H2O2] (compound B1, respectively. In contrast with the trinuclear secondary building unit of A1, the framework structure of B1 and B2 consists of dinuclear secondary building units in common, but with subtle distinction posed by the different size of the incorporated cations. These structural differences amidst the frameworks showed interesting aspects, including guest and void volume, and were used to explain the chemical trend observed in the system. Moreover, the physicochemical properties of the newly synthesized compound have been briefly discussed.

  18. Validation of single-plane fluoroscopy and 2D/3D shape-matching for quantifying shoulder complex kinematics.

    Science.gov (United States)

    Lawrence, Rebekah L; Ellingson, Arin M; Ludewig, Paula M

    2018-02-01

    Fluoroscopy and 2D/3D shape-matching has emerged as the standard for non-invasively quantifying kinematics. However, its accuracy has not been well established for the shoulder complex when using single-plane fluoroscopy. The purpose of this study was to determine the accuracy of single-plane fluoroscopy and 2D/3D shape-matching for quantifying full shoulder complex kinematics. Tantalum markers were implanted into the clavicle, humerus, and scapula of four cadaveric shoulders. Biplane radiographs were obtained with the shoulder in five humerothoracic elevation positions (arm at the side, 30°, 60°, 90°, maximum). Images from both systems were used to perform marker tracking, while only those images acquired with the primary fluoroscopy system were used to perform 2D/3D shape-matching. Kinematics errors due to shape-matching were calculated as the difference between marker tracking and 2D/3D shape-matching and expressed as root mean square (RMS) error, bias, and precision. Overall RMS errors for the glenohumeral joint ranged from 0.7 to 3.3° and 1.2 to 4.2 mm, while errors for the acromioclavicular joint ranged from 1.7 to 3.4°. Errors associated with shape-matching individual bones ranged from 1.2 to 3.2° for the humerus, 0.5 to 1.6° for the scapula, and 0.4 to 3.7° for the clavicle. The results of the study demonstrate that single-plane fluoroscopy and 2D/3D shape-matching can accurately quantify full shoulder complex kinematics in static positions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Reversible Single-Crystal-to-Single-Crystal Structural Transformation in a Mixed-Ligand 2D Layered Metal-Organic Framework: Structural Characterization and Sorption Study

    Directory of Open Access Journals (Sweden)

    Chih-Chieh Wang

    2017-12-01

    Full Text Available A 3D supramolecular network, [Cd(bipy(C4O4(H2O2]·3H2O (1 (bipy = 4,4′-bipyridine and C4O42− = dianion of H2C4O4, constructed by mixed-ligand two-dimensional (2D metal-organic frameworks (MOFs has been reported and structurally determined by the single-crystal X-ray diffraction method and characterized by other physicochemical methods. In 1, the C4O42− and bipy both act as bridging ligands connecting the Cd(II ions to form a 2D layered MOF, which are then extended to a 3D supramolecular network via the mutually parallel and interpenetrating arrangements among the 2D-layered MOFs. Compound 1 shows a two-step dehydration process with weight losses of 11.0% and 7.3%, corresponding to the weight-loss of three guest and two coordinated water molecules, respectively, and exhibits an interesting reversible single-crystal-to-single-crystal (SCSC structural transformation upon de-hydration and re-hydration for guest water molecules. The SCSC structural transformation have been demonstrated and monitored by single-crystal and X-ray powder diffraction, and thermogravimetic analysis studies.

  20. Assessment of gridded observations used for climate model validation in the Mediterranean region: the HyMeX and MED-CORDEX framework

    International Nuclear Information System (INIS)

    Flaounas, Emmanouil; Drobinski, Philippe; Borga, Marco; Calvet, Jean-Christophe; Delrieu, Guy; Morin, Efrat; Tartari, Gianni; Toffolon, Roberta

    2012-01-01

    This letter assesses the quality of temperature and rainfall daily retrievals of the European Climate Assessment and Dataset (ECA and D) with respect to measurements collected locally in various parts of the Euro-Mediterranean region in the framework of the Hydrological Cycle in the Mediterranean Experiment (HyMeX), endorsed by the Global Energy and Water Cycle Experiment (GEWEX) of the World Climate Research Program (WCRP). The ECA and D, among other gridded datasets, is very often used as a reference for model calibration and evaluation. This is for instance the case in the context of the WCRP Coordinated Regional Downscaling Experiment (CORDEX) and its Mediterranean declination MED-CORDEX. This letter quantifies ECA and D dataset uncertainties associated with temperature and precipitation intra-seasonal variability, seasonal distribution and extremes. Our motivation is to help the interpretation of the results when validating or calibrating downscaling models by the ECA and D dataset in the context of regional climate research in the Euro-Mediterranean region. (letter)

  1. Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation

    Directory of Open Access Journals (Sweden)

    Mekkaoui Choukri

    2012-10-01

    Full Text Available Abstract Background The study of myofiber reorganization in the remote zone after myocardial infarction has been performed in 2D. Microstructural reorganization in remodeled hearts, however, can only be fully appreciated by considering myofibers as continuous 3D entities. The aim of this study was therefore to develop a technique for quantitative 3D diffusion CMR tractography of the heart, and to apply this method to quantify fiber architecture in the remote zone of remodeled hearts. Methods Diffusion Tensor CMR of normal human, sheep, and rat hearts, as well as infarcted sheep hearts was performed ex vivo. Fiber tracts were generated with a fourth-order Runge-Kutta integration technique and classified statistically by the median, mean, maximum, or minimum helix angle (HA along the tract. An index of tract coherence was derived from the relationship between these HA statistics. Histological validation was performed using phase-contrast microscopy. Results In normal hearts, the subendocardial and subepicardial myofibers had a positive and negative HA, respectively, forming a symmetric distribution around the midmyocardium. However, in the remote zone of the infarcted hearts, a significant positive shift in HA was observed. The ratio between negative and positive HA variance was reduced from 0.96 ± 0.16 in normal hearts to 0.22 ± 0.08 in the remote zone of the remodeled hearts (p Conclusions A significant reorganization of the 3D fiber continuum is observed in the remote zone of remodeled hearts. The positive (rightward shift in HA in the remote zone is greatest in the subepicardium, but involves all layers of the myocardium. Tractography-based quantification, performed here for the first time in remodeled hearts, may provide a framework for assessing regional changes in the left ventricle following infarction.

  2. Real-time 2-D Phased Array Vector Flow Imaging

    DEFF Research Database (Denmark)

    Holbek, Simon; Hansen, Kristoffer Lindskov; Fogh, Nikolaj

    2018-01-01

    Echocardiography examination of the blood flow is currently either restricted to 1-D techniques in real-time or experimental off-line 2-D methods. This paper presents an implementation of transverse oscillation for real-time 2-D vector flow imaging (VFI) on a commercial BK Ultrasound scanner....... A large field-of-view (FOV) sequence for studying flow dynamics at 11 frames per second (fps) and a sequence for studying peak systolic velocities (PSV) with a narrow FOV at 36 fps were validated. The VFI sequences were validated in a flow-rig with continuous laminar parabolic flow and in a pulsating flow...

  3. Cultural Orientations Framework (COF) Assessment Questionnaire in Cross-Cultural Coaching: A Cross-Validation with Wave Focus Styles

    OpenAIRE

    Rojon, C; McDowall, A

    2010-01-01

    This paper outlines a cross-validation of the Cultural Orientations Framework assessment questionnaire\\ud (COF, Rosinski, 2007; a new tool designed for cross-cultural coaching) with the Saville Consulting\\ud Wave Focus Styles questionnaire (Saville Consulting, 2006; an existing validated measure of\\ud occupational personality), using data from UK and German participants (N = 222). The convergent and\\ud divergent validity of the questionnaire was adequate. Contrary to previous findings which u...

  4. Small polarons in 2D perovskites

    KAUST Repository

    Cortecchia, Daniele; Yin, Jun; Birowosuto, Muhammad D.; Lo, Shu-Zee A.; Gurzadyan, Gagik G.; Bruno, Annalisa; Bredas, Jean-Luc; Soci, Cesare

    2017-01-01

    We demonstrate that white light luminescence in two-dimensional (2D) perovskites stems from photoinduced formation of small polarons confined at specific sites of the inorganic framework in the form of self-trapped electrons and holes. We discuss their application in white light emitting devices and X-ray scintillators.

  5. Small polarons in 2D perovskites

    KAUST Repository

    Cortecchia, Daniele

    2017-11-02

    We demonstrate that white light luminescence in two-dimensional (2D) perovskites stems from photoinduced formation of small polarons confined at specific sites of the inorganic framework in the form of self-trapped electrons and holes. We discuss their application in white light emitting devices and X-ray scintillators.

  6. Design, Fabrication, and Testing of Active Skin Antenna with 3D Printing Array Framework

    Directory of Open Access Journals (Sweden)

    Jinzhu Zhou

    2017-01-01

    Full Text Available An active skin antenna with structural load-bearing and electromagnetic functions is usually installed in the structural surface of mobile vehicles such as aircrafts, warships, and high-speed train. This paper presents the design, fabrication, and testing of a novel active skin antenna which consists of an encapsulation shell, antenna skin, and RF and beam control circuits. The antenna skin which consists of the facesheet, honeycomb, array framework, and microstrip antenna elements was designed by using Bayesian optimization, in order to improve the design efficiency. An active skin antenna prototype with 32 microstrip antenna elements was fabricated by using a hybrid manufacturing method. In this method, 3D printing technology was applied to fabricate the array framework, and the different layers were bonded to form the final antenna skin by using traditional composite process. Some experimental testing was conducted, and the testing results validate the feasibility the proposed antenna skin structure. The proposed design and fabrication technique is suitable for the development of conformal load-bearing antenna or smart skin antenna installed in the structural surface of aircraft, warships, and armored vehicles.

  7. Validation of MCNP and ORIGEN-S 3-D computational model for reactivity predictions during BR2 operation

    International Nuclear Information System (INIS)

    Kalcheva, S.; Koonen, E.; Ponsard, B.

    2005-01-01

    The Belgian Material Test Reactor (MTR) BR2 is strongly heterogeneous high flux engineering test reactor at SCK-CEN (Centre d'Etude de l'energie Nucleaire) in Mol at a thermal power 60 to 100 MW. It deploys highly enriched uranium, water cooled concentric plate fuel elements, positioned inside a beryllium reflector with complex hyperboloid arrangement of test holes. The objective of this paper is the validation of a MCNP and ORIGEN-S 3D model for reactivity predictions of the entire BR2 core during reactor operation. We employ the Monte Carlo code MCNP-4C for evaluating the effective multiplication factor k eff and 3D space dependent specific power distribution. The 1D code ORIGEN-S is used for calculation of isotopic fuel depletion versus burn up and preparation of a database (DB) with depleted fuel compositions. The approach taken is to evaluate the 3D power distribution at each time step and along with DB to evaluate the 3D isotopic fuel depletion at the next step and to deduce the corresponding shim rods positions of the reactor operation. The capabilities of the both codes are fully exploited without constraints on the number of involved isotope depletion chains or increase of the computational time. The reactor has a complex operation, with important shutdowns between cycles, and its reactivity is strongly influenced by poisons, mainly 3 He and 6 Li from the beryllium reflector, and burnable absorbers 149 Sm and 10 B in the fresh UAlx fuel. Our computational predictions for the shim rods position at various restarts are within 0.5$ (β eff =0.0072). (author)

  8. A New Open-framework Iron Borophosphate from Ionic Liquids: KFe[BP2O8(OH

    Directory of Open Access Journals (Sweden)

    Guangmei Wang

    2011-04-01

    Full Text Available A new open-framework iron borophosphate, KFe[BP2O8(OH], has been obtained by ionothermal synthesis from KH2PO4, FeCl3∙4H2O, H3BO3 and [C4mpyr]Br (1-butyl-1-methylpyrrolidinium bromide. Single-crystal X-ray diffraction analysis shows that KFe[BP2O8(OH] (monoclinic, P21/c, a = 9.372(2 Å , b = 8.146(2Å , c = 9.587(2 Å, β = 101.18(3°, V = 718.0(2Å3 and Z = 4 has a three-dimensional (3-D framework structure composed by {Fe(IIIO5(OH} octahedra as well as {BO3(OH} and {PO4} tetrahedra. As anionic structural sub-unit, KFe[BP2O8(OH], contains an infinite open-branched {[BP2O8(OH]4-} chain which is formed by alternating {BO3(OH} and {PO4} tetrahedra. {Fe(IIIO5(OH} octahedra share common O corners with five phosphate tetrahedra and the OH corner links to the hydrogen borate group to give a 3D framework. The negative charges of the inorganic framework are balanced by K+ ions.

  9. Benchmarking of FA2D/PARCS Code Package

    International Nuclear Information System (INIS)

    Grgic, D.; Jecmenica, R.; Pevec, D.

    2006-01-01

    FA2D/PARCS code package is used at Faculty of Electrical Engineering and Computing (FER), University of Zagreb, for static and dynamic reactor core analyses. It consists of two codes: FA2D and PARCS. FA2D is a multigroup two dimensional transport theory code for burn-up calculations based on collision probability method, developed at FER. It generates homogenised cross sections both of single pins and entire fuel assemblies. PARCS is an advanced nodal code developed at Purdue University for US NRC and it is based on neutron diffusion theory for three dimensional whole core static and dynamic calculations. It is modified at FER to enable internal 3D depletion calculation and usage of neutron cross section data in a format produced by FA2D and interface codes. The FA2D/PARCS code system has been validated on NPP Krsko operational data (Cycles 1 and 21). As we intend to use this code package for development of IRIS reactor loading patterns the first logical step was to validate the FA2D/PARCS code package on a set of IRIS benchmarks, starting from simple unit fuel cell, via fuel assembly, to full core benchmark. The IRIS 17x17 fuel with erbium burnable absorber was used in last full core benchmark. The results of modelling the IRIS full core benchmark using FA2D/PARCS code package have been compared with reference data showing the adequacy of FA2D/PARCS code package model for IRIS reactor core design.(author)

  10. A framework for simulating ultrasound imaging based on first order nonlinear pressure–velocity relations

    DEFF Research Database (Denmark)

    Du, Yigang; Fan, Rui; Li, Yong

    2016-01-01

    An ultrasound imaging framework modeled with the first order nonlinear pressure–velocity relations (NPVR) based simulation and implemented by a half-time staggered solution and pseudospectral method is presented in this paper. The framework is capable of simulating linear and nonlinear ultrasound...... propagation and reflections in a heterogeneous medium with different sound speeds and densities. It can be initialized with arbitrary focus, excitation and apodization for multiple individual channels in both 2D and 3D spatial fields. The simulated channel data can be generated using this framework......, and ultrasound image can be obtained by beamforming the simulated channel data. Various results simulated by different algorithms are illustrated for comparisons. The root mean square (RMS) errors for each compared pulses are calculated. The linear propagation is validated by an angular spectrum approach (ASA...

  11. Integrating a Trust Framework with a Distributed Certificate Validation Scheme for MANETs

    Directory of Open Access Journals (Sweden)

    Marias Giannis F

    2006-01-01

    Full Text Available Many trust establishment solutions in mobile ad hoc networks (MANETs rely on public key certificates. Therefore, they should be accompanied by an efficient mechanism for certificate revocation and validation. Ad hoc distributed OCSP for trust (ADOPT is a lightweight, distributed, on-demand scheme based on cached OCSP responses, which provides certificate status information to the nodes of a MANET. In this paper we discuss the ADOPT scheme and issues on its deployment over MANETs. We present some possible threats to ADOPT and suggest the use of a trust assessment and establishment framework, named ad hoc trust framework (ATF, to support ADOPT's robustness and efficiency. ADOPT is deployed as a trust-aware application that provides feedback to ATF, which calculates the trustworthiness of the peer nodes' functions and helps ADOPT to improve its performance by rapidly locating valid certificate status information. Moreover, we introduce the TrustSpan algorithm to reduce the overhead that ATF produces, and the TrustPath algorithm to identify and use trusted routes for propagating sensitive information, such as third parties' accusations. Simulation results show that ATF adds limited overhead compared to its efficiency in detecting and isolating malicious and selfish nodes. ADOPT's reliability is increased, since it can rapidly locate a legitimate response by using information provided by ATF.

  12. Validation of the EQ-5D in a general population sample in urban China.

    Science.gov (United States)

    Wang, Hong-Mei; Patrick, Donald L; Edwards, Todd C; Skalicky, Anne M; Zeng, Hai-Yan; Gu, Wen-Wen

    2012-02-01

    To evaluate the reliability and validity of the EQ-5D in a general population sample in urban China. Thousand and eight hundred respondents in 18 communities of Hangzhou, China were recruited by multi-stage stratified random sampling. Respondents self-administered a questionnaire including the EQ-5D, the SF-36, and demographic questions. Test-retest reliability at 2-week intervals was evaluated using Kappa coefficient, the intraclass correlation coefficient. The standard error of measurement (SEM) was used to indicate the absolute measurement error. Construct validity was established using convergent, discriminant, and known groups analyses. Complete data for all EQ-5D dimensions were available for 1,747 respondents (97%). Kappa values were from 0.35 to 1.0. The ICCs of test-retest reliability were 0.53 for the EQ-5D index score and 0.87 for the EQ VAS score. The SEM values were 0.13 (9.22% range) and 4.20 (4.20% range) for the EQ-5D index and EQ VAS scores, respectively. The Pearson's correlation coefficients between the EQ-5D and the SF-36 were stronger between comparable dimensions than those between less comparable dimensions, demonstrating convergent and discriminant evidence of construct validity. The Chinese EQ-5D distinguished well between known groups: respondents who reported poor general health and chronic diseases had worse HRQoL than those without. Older people, females, people widowed or divorced, and those with a lower socioeconomic status reported poorer HRQoL. Respondents reporting no problems on any EQ-5D dimension had better scores on the SF-36 summary scores than those reporting problems. The Chinese version of the EQ-5D demonstrated acceptable construct validity and fair to moderate levels of test-retest reliability in an urban general population in China.

  13. Reverse Flow Routing in a Bayesian Framework Using a GPU-accelerated 2D Shallow Water Model

    Science.gov (United States)

    D'Oria, M.; Ferrari, A.; Mignosa, P.; Tanda, M. G.; Vacondio, R.

    2017-12-01

    Knowledge of discharge hydrographs in specific sites of natural rivers is important for water resource management, flood frequency analysis, design of structures, etc. Many times, the flood hydrograph is needed in a river section upstream of a monitoring station; here the flood wave differs from the upstream one because of the effects of resistance, channel storage, lateral inflow, etc. Reverse flow routing is a method that allows obtaining hydrographs in upstream ungauged stations using information available at downstream monitored sites. In this study, we propose an inverse procedure, based on a Bayesian Geostatistical Approach, to solve the reverse problem. The upstream flow values over time (parameters) are considered as random variables and a-priori information about the parameters and observations (downstream discharge or water level values) are combined together in a Bayesian framework. The methodology needs a forward model of the considered open channel that includes the upstream ungauged station and the downstream gauged one and it is able to describe, with sufficient accuracy, the hydraulic routing processes. In many real cases, especially when large floodable areas are involved, a 1D hydraulic model is not able to capture the complex river hydrodynamic and a 2D model must be used. The inverse procedure requires a high number of flow model run to linearize the forward problem through multiple evaluations of a Jacobian matrix (sensitivity of each observation to each parameter) using a finite difference approach. For this reason, the computational efficiency of the forward model is a crucial element to reduce the overall computational costs. Therefore, in this work we used, in combination with the inverse procedure, a GPU-parallel numerical model for the solution of the 2D Shallow Water equations (implemented in CUDA/C++ code) that allows achieving ratio of physical to computational time of about 500-1000 (depending on the test case features). In addition

  14. Validation of the MC{sup 2}-3/DIF3D Code System for Control Rod Worth via the BFS-75-1 Reactor Physics Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Sunghwan; Kim, Sang Ji [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, control rod worths of the BFS-75-1 reactor physics experiments were examined using continuous energy MCNP models and deterministic MC2-3/DIF3D models based on the ENDF/B-VII.0 library. We can conclude that the ENDF/B-VII.0 library shows very good agreement in small-size metal uranium fuel loaded core which is surrounded by the depleted uranium blanket. However, the control rod heterogeneity effect reported by the reference is not significant in this problem because the tested control rod models were configured by single rod. Hence comparison with other control rod worth measurements data such as the BFS-109-2A reactor physics experiment is planned as a future study. The BFS-75-1 critical experiment was carried out in the BFS-1 facility of IPPE in Russia within the framework of validating an early phase of KALIMER- 150 design. The Monte-Carlo model of the BFS- 75-1 critical experiment had been developed. However, due to incomplete information for the BFS- 75-1 experiments, Monte-Carlo models had been generated for the reference criticality and sodium void reactivity measurements with disk-wise homogeneous model. Recently, KAERI performed another physics experiment, BFS-109-2A, by collaborating with Russian IPPE. During the review process of the experimental report of the BFS-109-2A critical experiments, valuable information for the BFS-1 facility which can also be used for the BFS-75-1 experiments was discovered.

  15. A JOINT FRAMEWORK FOR 4D SEGMENTATION AND ESTIMATION OF SMOOTH TEMPORAL APPEARANCE CHANGES.

    Science.gov (United States)

    Gao, Yang; Prastawa, Marcel; Styner, Martin; Piven, Joseph; Gerig, Guido

    2014-04-01

    Medical imaging studies increasingly use longitudinal images of individual subjects in order to follow-up changes due to development, degeneration, disease progression or efficacy of therapeutic intervention. Repeated image data of individuals are highly correlated, and the strong causality of information over time lead to the development of procedures for joint segmentation of the series of scans, called 4D segmentation. A main aim was improved consistency of quantitative analysis, most often solved via patient-specific atlases. Challenging open problems are contrast changes and occurance of subclasses within tissue as observed in multimodal MRI of infant development, neurodegeneration and disease. This paper proposes a new 4D segmentation framework that enforces continuous dynamic changes of tissue contrast patterns over time as observed in such data. Moreover, our model includes the capability to segment different contrast patterns within a specific tissue class, for example as seen in myelinated and unmyelinated white matter regions in early brain development. Proof of concept is shown with validation on synthetic image data and with 4D segmentation of longitudinal, multimodal pediatric MRI taken at 6, 12 and 24 months of age, but the methodology is generic w.r.t. different application domains using serial imaging.

  16. Non-reciprocal elastic wave propagation in 2D phononic membranes with spatiotemporally varying material properties

    Science.gov (United States)

    Attarzadeh, M. A.; Nouh, M.

    2018-05-01

    One-dimensional phononic materials with material fields traveling simultaneously in space and time have been shown to break elastodynamic reciprocity resulting in unique wave propagation features. In the present work, a comprehensive mathematical analysis is presented to characterize and fully predict the non-reciprocal wave dispersion in two-dimensional space. The analytical dispersion relations, in the presence of the spatiotemporal material variations, are validated numerically using finite 2D membranes with a prescribed number of cells. Using omnidirectional excitations at the membrane's center, wave propagations are shown to exhibit directional asymmetry that increases drastically in the direction of the material travel and vanishes in the direction perpendicular to it. The topological nature of the predicted dispersion in different propagation directions are evaluated using the computed Chern numbers. Finally, the degree of the 2D non-reciprocity is quantified using a non-reciprocity index (NRI) which confirms the theoretical dispersion predictions as well as the finite simulations. The presented framework can be extended to plate-type structures as well as 3D spatiotemporally modulated phononic crystals.

  17. Performance Prediction and Validation: Data, Frameworks, and Considerations

    Energy Technology Data Exchange (ETDEWEB)

    Tinnesand, Heidi

    2017-05-19

    Improving the predictability and reliability of wind power generation and operations will reduce costs and potentially establish a framework to attract new capital into the distributed wind sector, a key cost reduction requirement highlighted in results from the distributed wind future market assessment conducted with dWind. Quantifying and refining the accuracy of project performance estimates will also directly address several of the key challenges identified by industry stakeholders in 2015 as part of the distributed wind resource assessment workshop and be cross-cutting for several other facets of the distributed wind portfolio. This presentation covers the efforts undertaken in 2016 to address these topics.

  18. [Validity and reliability of the spanish EQ-5D-Y proxy version].

    Science.gov (United States)

    Gusi, N; Perez-Sousa, M A; Gozalo-Delgado, M; Olivares, P R

    2014-10-01

    A proxy version of the EQ-5D-Y, a questionnaire to evaluate the Health Related Quality of Life (HRQoL) in children and adolescents, has recently been developed. There are currently no data on the validity and reliability of this tool. The objective of this study was to analyze the validity and reliability of the EQ-5D-Y proxy version. A core set of self-report tools, including the Spanish version of the EQ-5D-Y were administered to a group of Spanish children and adolescents drawn from the general population. A similar core set of internationally standardized proxy tools, including the EQ-5D-Y proxy version were administered to their parents. Test-retest reliability was determined, and correlations with other generic measurements of HRQoL were calculated. Additionally, known group validity was examined by comparing groups with a priori expected differences in HRQoL. The agreement between the self-report and proxy version responses was also calculated. A total of 477 children and adolescents and their parents participated in the study. One week later, 158 participants completed the EQ-5D-Y/EQ-5D-Y proxy to facilitate reliability analysis. Agreement between the test-retest scores was higher than 88% for EQ-5D-Y self-report, and proxy version. Correlations with other health measurements showed similar convergent validity to that observed in the international EQ-5D-Y. Agreement between the self-report and proxy versions ranged from 72.9% to 97.1%. The results provide preliminary evidence of the reliability and validity of the EQ-5D-Y proxy version. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  19. Internet-based hardware/software co-design framework for embedded 3D graphics applications

    Directory of Open Access Journals (Sweden)

    Wong Weng-Fai

    2011-01-01

    Full Text Available Abstract Advances in technology are making it possible to run three-dimensional (3D graphics applications on embedded and handheld devices. In this article, we propose a hardware/software co-design environment for 3D graphics application development that includes the 3D graphics software, OpenGL ES application programming interface (API, device driver, and 3D graphics hardware simulators. We developed a 3D graphics system-on-a-chip (SoC accelerator using transaction-level modeling (TLM. This gives software designers early access to the hardware even before it is ready. On the other hand, hardware designers also stand to gain from the more complex test benches made available in the software for verification. A unique aspect of our framework is that it allows hardware and software designers from geographically dispersed areas to cooperate and work on the same framework. Designs can be entered and executed from anywhere in the world without full access to the entire framework, which may include proprietary components. This results in controlled and secure transparency and reproducibility, granting leveled access to users of various roles.

  20. Experimental Validation of Mathematical Framework for Fast Switching Valves used in Digital Hydraulic Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Roemer, Daniel Beck; Bech, Michael Møller

    2015-01-01

    of 10 kW during switching (mean of approximately 250 W) and a pressure loss below 0.5 bar at 600 l/min. The main goal of this article is validate parts of the mathematical framework based on a series of experiments. Furthermore, this article aims to document the experience gained from the experimental...

  1. [GRADE Evidence to Decision (EtD) frameworks: a systematic and transparent approach to making well informed healthcare choices. 2: Clinical practice guidelines].

    Science.gov (United States)

    Alonso-Coello, Pablo; Oxman, Andrew D; Moberg, Jenny; Brignardello-Petersen, Romina; Akl, Elie A; Davoli, Marina; Treweek, Shaun; Mustafa, Reem A; Vandvik, Per O; Meerpohl, Joerg; Guyatt, Gordon H; Schünemann, Holger J

    Clinicians do not have the time or resources to consider the underlying evidence for the myriad decisions they must make each day and, as a consequence, rely on recommendations from clinical practice guidelines. Guideline panels should consider all the relevant factors (criteria) that influence a decision or recommendation in a structured, explicit, and transparent way and provide clinicians with clear and actionable recommendations. In this article, we will describe the Evidence to Decision (EtD) frameworks for clinical practice recommendations. The general structure of the EtD framework for clinical recommendations is similar to EtD frameworks for other types of recommendations and decisions, and includes formulation of the question, an assessment of the different criteria, and conclusions. Clinical recommendations require considering criteria differently, depending on whether an individual patient or a population perspective is taken. For example, from an individual patient's perspective, out-of-pocket costs are an important consideration, whereas, from a population perspective, resource use (not only out-of-pocket costs) and cost effectiveness are important. From a population perspective, equity, acceptability, and feasibility are also important considerations, whereas the importance of these criteria is often limited from an individual patient perspective. Specific subgroups for which different recommendations may be required should be clearly identified and considered in relation to each criterion because judgments might vary across subgroups. This article is a translation of the original article published in the British Medical Journal. The EtD frameworks are currently used in the Clinical Practice Guideline Programme of the Spanish National Health System, co-ordinated by GuíaSalud. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Results of the AVATAR project for the validation of 2D aerodynamic models with experimental data of the DU95W180 airfoil with unsteady flap

    DEFF Research Database (Denmark)

    Ferreira, C.; Gonzalez, A.; Baldacchino, D.

    2016-01-01

    , for different angle of attack and flap settings, including unsteady oscillatory trailing-edge-flap motion, carried out within the framework of WP3: Models for Flow Devices and Flow Control, Task 3.1: CFD and Experimental Database. The aerodynamics codes are: AdaptFoil2D, Foil2W, FLOWer, MaPFlow, OpenFOAM, Q3UIC...

  3. A 3-D open-framework material with intrinsic chiral topology used as a stationary phase in gas chromatography.

    Science.gov (United States)

    Xie, Sheng-Ming; Zhang, Xin-Huan; Zhang, Ze-Jun; Zhang, Mei; Jia, Jia; Yuan, Li-Ming

    2013-04-01

    Compared with liquid chromatography and capillary electrophoresis, the diversity of gas chromatography chiral stationary phases is rather limited. Here, we report the fabrication of Co(D-Cam)1/2(bdc)1/2(tmdpy) (D-Cam = D-camphoric acid; bdc = 1,4-benzenedicarboxylate; tmdpy = 4,4'-trimethylenedipyridine)-coated open tubular columns for high-resolution gas chromatographic separation of compounds. The Co(D-Cam)1/2(bdc)1/2(tmdpy) compound possesses a 3-D framework containing enantiopure building blocks embedded in intrinsically chiral topological nets. In this study, two fused-silica open tubular columns with different inner diameters and lengths, including column A (30 m × 530 μm i.d.) and column B (2 m × 75 μm i.d.), were prepared by a dynamic coating method using Co-(D-Cam)1/2(bdc)1/2(tmdpy) as the stationary phase. The chromatographic properties of the two columns were investigated using n-dodecane as the test compound at 120 °C. The number of theoretical plates (plates/m) of the two metal-organic framework columns was 1,450 and 3,100, respectively. The separation properties were evaluated using racemates, isomers, alkanes, alcohols, and Grob's test mixture. The limit of detection and limit of quantification were found to be 0.125 and 0.417 ng for citronellal enantiomers, respectively. Repeatability (n = 6) showed lower than 0.25 % relative standard deviation (RSD) for retention times and lower than 2.2 % RSD for corrected peak areas. The experimental results showed that the stationary phase has excellent selectivity and also possesses good recognition ability toward these organic compounds, especially chiral compounds.

  4. 3D architecture constructed via the confined growth of MoS2 nanosheets in nanoporous carbon derived from metal-organic frameworks for efficient hydrogen production.

    Science.gov (United States)

    Liu, Yun; Zhou, Xiaoli; Ding, Tao; Wang, Chunde; Yang, Qing

    2015-11-21

    The design and synthesis of robust, high-performance and low-cost three-dimensional (3D) hierarchical structured materials for the electrochemical reduction of water to generate hydrogen is of great significance for practical water splitting applications. In this study, we develop an in situ space-confined method to synthesize an MoS2-based 3D hierarchical structure, in which the MoS2 nanosheets grow in the confined nanopores of metal-organic frameworks (MOFs)-derived 3D carbons as electrocatalysts for efficient hydrogen production. Benefiting from its unique structure, which has more exposed active sites and enhanced conductivity, the as-prepared MoS2/3D nanoporous carbon (3D-NPC) composite exhibits remarkable electrocatalytic activity for the hydrogen evolution reaction (HER) with a small onset overpotential of ∼0.16 V, large cathodic currents, small Tafel slope of 51 mV per decade and good durability. We anticipate that this in situ confined growth provides new insights into the construction of high performance catalysts for energy storage and conversion.

  5. Validation of an e-Learning 3.0 Critical Success Factors Framework: A Qualitative Research

    Science.gov (United States)

    Miranda, Paula; Isaias, Pedro; Costa, Carlos J.; Pifano, Sara

    2017-01-01

    Aim/Purpose: As e-Learning 3.0 evolves from a theoretical construct into an actual solution for online learning, it becomes crucial to accompany this progress by scrutinising the elements that are at the origin of its success. Background: This paper outlines a framework of e-Learning 3.0's critical success factors and its empirical validation.…

  6. A rod-packing microporous hydrogen-bonded organic framework for highly selective separation of C2H2/CO2at room temperature

    KAUST Repository

    Li, Peng

    2014-11-13

    Self-assembly of a trigonal building subunit with diaminotriazines (DAT) functional groups leads to a unique rod-packing 3D microporous hydrogen-bonded organic framework (HOF-3). This material shows permanent porosity and demonstrates highly selective separation of C2H2/CO2 at ambient temperature and pressure.

  7. A rod-packing microporous hydrogen-bonded organic framework for highly selective separation of C2H2/CO2at room temperature

    KAUST Repository

    Li, Peng; He, Yabing; Zhao, Yunfeng; Weng, Linhong; Wang, Hailong; Krishna, Rajamani A A; Wu, Hui; Zhou, Wei; O'Keeffe, Michael A.; Han, Yu; Chen, Banglin

    2014-01-01

    Self-assembly of a trigonal building subunit with diaminotriazines (DAT) functional groups leads to a unique rod-packing 3D microporous hydrogen-bonded organic framework (HOF-3). This material shows permanent porosity and demonstrates highly selective separation of C2H2/CO2 at ambient temperature and pressure.

  8. Design and Validation of In-Source Atmospheric Pressure Photoionization Hydrogen/Deuterium Exchange Mass Spectrometry with Continuous Feeding of D2O.

    Science.gov (United States)

    Acter, Thamina; Lee, Seulgidaun; Cho, Eunji; Jung, Maeng-Joon; Kim, Sunghwan

    2018-01-01

    In this study, continuous in-source hydrogen/deuterium exchange (HDX) atmospheric pressure photoionization (APPI) mass spectrometry (MS) with continuous feeding of D 2 O was developed and validated. D 2 O was continuously fed using a capillary line placed on the center of a metal plate positioned between the UV lamp and nebulizer. The proposed system overcomes the limitations of previously reported APPI HDX-MS approaches where deuterated solvents were premixed with sample solutions before ionization. This is particularly important for APPI because solvent composition can greatly influence ionization efficiency as well as the solubility of analytes. The experimental parameters for APPI HDX-MS with continuous feeding of D 2 O were optimized, and the optimized conditions were applied for the analysis of nitrogen-, oxygen-, and sulfur-containing compounds. The developed method was also applied for the analysis of the polar fraction of a petroleum sample. Thus, the data presented in this study clearly show that the proposed HDX approach can serve as an effective analytical tool for the structural analysis of complex mixtures. Graphical abstract ᅟ.

  9. Determination and validation of mTOR kinase-domain 3D structure by homology modeling

    Directory of Open Access Journals (Sweden)

    Lakhlili W

    2015-07-01

    Full Text Available Wiame Lakhlili,1 Gwénaël Chevé,2 Abdelaziz Yasri,2 Azeddine Ibrahimi1 1Laboratoire de Biotechnologie (MedBiotech, Faculté de Médecine et de Pharmacie de Rabat, Université Mohammed V de Rabat, Rabat, Morroco; 2OriBase Pharma, Cap Gamma, Parc Euromédecine, Montpellier, France Abstract: The AKT/mammalian target of rapamycin (mTOR pathway is considered as one of the commonly activated and deregulated signaling pathways in human cancer. mTOR is associated with other proteins in two molecular complexes: mTOR complex 1/Raptor and the mTOR complex 2/Rictor. Using the crystal structure of the related lipid kinase PI3Kγ, we built a model of the catalytic region of mTOR. The modeling of the three-dimensional (3D structure of the mTOR was performed by homology modeling program SWISS-MODEL. The quality and validation of the obtained model were performed using PROCHECK and PROVE softwares. The overall stereochemical property of the protein was assessed by the Ramachandran plot. The model validation was also done by docking of known inhibitors. In this paper, we describe and validate a 3D model for the mTOR catalytic site.Keywords: mTOR, homology modeling, mTOR kinase-domain, docking

  10. Data validation report for the 100-D Ponds Operable Unit: 100-D ponds sampling

    International Nuclear Information System (INIS)

    Stankovich, M.T.

    1994-01-01

    Westinghouse-Hanford has requested that 100 percent of the Sample Delivery Groups be validated for the 100-D Ponds Operable Unit Sampling Investigation. Therefore the data from the chemical analysis of all 30 samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site

  11. Syntheses, crystal structures and luminescent properties of two new 1D d 1 coordination polymers constructed from 2,2'-bibenzimidazole and 1,4-benzenedicarboxylate

    International Nuclear Information System (INIS)

    Wen Lili; Li Yizhi; Dang Dongbin; Tian Zhengfang; Ni Zhaoping; Meng Qingjin

    2005-01-01

    Two novel interesting d 1 metal coordination polymers, [Zn(H 2 bibzim)(BDC)] n (1) and [Cd(H 2 bibzim)(BDC)] n (2) [H 2 bibzim=2,2'-bibenzimidazole, BDC=1,4-benzenedicarboxylate] have been synthesized under solvothermal conditions and structurally characterized. Both 1 and 2 are constructed from infinite neutral zigzag-like one-dimensional (1D) chains. The π-π interactions and interchain hydrogen-bonding interactions further extend the 1D arrangement to generate a 3D supramolecular architecture for 1 and 2. Both complexes have high thermal stability and display strong blue fluorescent emissions in the solid state upon photo-excitation at 365 nm at room temperature. They are the first two examples that 2,2'-bibenzimidazole has been introduced into the d 1 coordination polymeric framework

  12. Construct validity of SF-6D health state utility values in an employed population.

    Science.gov (United States)

    Baxter, Siyan; Sanderson, Kristy; Venn, Alison; Otahal, Petr; Palmer, Andrew J

    2015-04-01

    Health utility values permit cost utility analysis in workplace health promotion; however, utility measures of working populations have not been validated. To investigate construct validity of SF-6D health utility in a public service workforce. SF-12v2 Health Survey was administered to 3,408 randomly selected public service employees in Australia in 2010. SF-12 scores were converted to SF-6D health utility values. Associations and correlates of SF-6D with health, socio-demographic and work characteristics [comorbidities, body mass index (BMI), Kessler-10 psychological distress (K10), education, salary, effort-reward imbalance (ERI), absenteeism] were explored. Ceiling effects were analysed. Nationally representative employee SF-6D values from the Household, Income and Labour Dynamics in Australia (HILDA) survey (n = 11,234) were compared. All analyses were stratified by sex. Mean (SE) age was 45.7 (0.35) males; 44.5 (0.22) females. Females represented 72 % of the sample. Mean (SE) health utility 0.792 (0.004); 0.771 (0.003) was higher in males. SF-6D demonstrated both a significant inverse association (p negative correlations (female; male) with K10 (r = -0.63; r = -0.66), comorbidity count (r = -0.40; r = -0.33), ERI (r = -0.37; r = -0.34) and absenteeism (p imbalance and absenteeism are negatively associated with employee health. SF-6D is a valid measure of perceived health states in working populations.

  13. Dynamics and Chemistry in Jovian Atmospheres: 2D Hydrodynamical Simulations

    Science.gov (United States)

    Bordwell, B. R.; Brown, B. P.; Oishi, J.

    2016-12-01

    A key component of our understanding of the formation and evolution of planetary systems is chemical composition. Problematically, however, in the atmospheres of cooler gas giants, dynamics on the same timescale as chemical reactions pull molecular abundances out of thermochemical equilibrium. These disequilibrium abundances are treated using what is known as the "quench" approximation, based upon the mixing length theory of convection. The validity of this approximation is questionable, though, as the atmospheres of gas giants encompass two distinct dynamic regimes: convective and radiative. To resolve this issue, we conduct 2D hydrodynamical simulations using the state-of-the-art pseudospectral simulation framework Dedalus. In these simulations, we solve the fully compressible equations of fluid motion in a local slab geometry that mimics the structure of a planetary atmosphere (convective zone underlying a radiative zone). Through the inclusion of passive tracers, we explore the transport properties of both regimes, and assess the validity of the classical eddy diffusion parameterization. With the addition of active tracers, we examine the interactions between dynamical and chemical processes, and generate prescriptions for the observational community. By providing insight into mixing and feedback mechanisms in Jovian atmospheres, this research lays a solid foundation for future global simulations and the construction of physically-sound models for current and future observations.

  14. BranchAnalysis2D/3D automates morphometry analyses of branching structures.

    Science.gov (United States)

    Srinivasan, Aditya; Muñoz-Estrada, Jesús; Bourgeois, Justin R; Nalwalk, Julia W; Pumiglia, Kevin M; Sheen, Volney L; Ferland, Russell J

    2018-01-15

    Morphometric analyses of biological features have become increasingly common in recent years with such analyses being subject to a large degree of observer bias, variability, and time consumption. While commercial software packages exist to perform these analyses, they are expensive, require extensive user training, and are usually dependent on the observer tracing the morphology. To address these issues, we have developed a broadly applicable, no-cost ImageJ plugin we call 'BranchAnalysis2D/3D', to perform morphometric analyses of structures with branching morphologies, such as neuronal dendritic spines, vascular morphology, and primary cilia. Our BranchAnalysis2D/3D algorithm allows for rapid quantification of the length and thickness of branching morphologies, independent of user tracing, in both 2D and 3D data sets. We validated the performance of BranchAnalysis2D/3D against pre-existing software packages using trained human observers and images from brain and retina. We found that the BranchAnalysis2D/3D algorithm outputs results similar to available software (i.e., Metamorph, AngioTool, Neurolucida), while allowing faster analysis times and unbiased quantification. BranchAnalysis2D/3D allows inexperienced observers to output results like a trained observer but more efficiently, thereby increasing the consistency, speed, and reliability of morphometric analyses. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Curvilinear 3-D Imaging Using Row--Column-Addressed 2-D Arrays with a Diverging Lens: Feasibility Study

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Beers, Christopher

    2017-01-01

    imaging. Extended FOV and low channel count of double-curved RCA 2-D arrays make 3-D imaging possible with equipment in the price range of conventional 2-D imaging. This study proposes a delay-and-sum beamformation scheme specific to double-curved RCA 2-D arrays and validates its focusing ability based...... of this study demonstrate that the proposed beamforming approach is accurate for achieving correct time-of-flight calculations, and hence avoids geometrical distortions....

  16. 3D hollow framework of GeOx with ultrathin shell for improved anode performance in lithium-ion batteries

    International Nuclear Information System (INIS)

    Fang, Zhen; Qiang, Tingting; Fang, Jiaxin; Song, Yixuan; Ma, Qiuyang; Ye, Ming; Qiang, Feiqiang; Geng, Baoyou

    2015-01-01

    Highlights: • 3D hollow framework of GeO x was synthesized using hydrothermal procedure. • The obtained GeO x 3D hollow framework has large surface area and porous thin shell. • The structure improved the cycle and rate performances. - Abstract: In this paper, 3D hollow framework of GeO x is synthesized using a bubble-template hydrothermal procedure. The as-obtained hollow structure exhibits excellent cycling performance and rate capability in comparison with GeO x nanoparticles when used as an anode material in lithium ion batteries. The GeO x 3D hollow framework shows a high capacity of up to 1480 mAh·g −1 and 1109 mAh·g −1 at 80 mA·g −1 and 1600 mA·g −1 current density, respectively. The excellent lithium storage performance can be attributed to the unique 3D hollow framework. The framework not only acts as the buffer layer to alleviate the strain during lithiation, but also facilitates the electron transfer during the charge/discharge processes

  17. A series of novel lanthanide carboxyphosphonates with a 3D framework structure: synthesis, structure, and luminescent and magnetic properties.

    Science.gov (United States)

    Chen, Kai; Dong, Da-Peng; Sun, Zhen-Gang; Jiao, Cheng-Qi; Li, Chao; Wang, Cheng-Lin; Zhu, Yan-Yu; Zhao, Yan; Zhu, Jiang; Sun, Shou-Hui; Zheng, Ming-Jing; Tian, Hui; Chu, Wei

    2012-08-28

    By introduction of 1,4-benzenedicarboxylic acid as the second organic ligand, a series of novel lanthanide carboxyphosphonates with a 3D framework structure, namely, [Ln(3)(H(2)L)(HL)(2)(bdc)(2)(H(2)O)]·7H(2)O (Ln = La (1), Ce (2), Pr (3), Nd (4), Sm (5), Eu (6), Gd (7), Tb (8); H(3)L = H(2)O(3)PCH(2)NC(5)H(9)COOH; H(2)bdc = HOOCC(6)H(4)COOH) have been synthesized under hydrothermal conditions. Compounds are isostructural and feature a 3D framework in which Ln(III) polyhedra are interconnected by bridging {CPO(3)} tetrahedra into 2D inorganic layers parallel to the ab plane. The organic groups of H(2)L(-) are grafted on the two sides of the layer. These layers are further cross-linked by the bdc(2-) ligands from one layer to the Ln atoms from the other into a pillared-layered architecture with one-dimensional channel system along the a axis. The thermal stability of compounds has been investigated. Luminescent properties of compounds , and the magnetic properties of compound have also been studied.

  18. Specification and Preliminary Validation of IAT (Integrated Analysis Techniques) Methods: Executive Summary.

    Science.gov (United States)

    1985-03-01

    conceptual framwork , and preliminary validation of IAT concepts. Planned work for FY85, including more extensive validation, is also described. 20...Developments: Required Capabilities .... ......... 10 2-1 IAT Conceptual Framework - FY85 (FEO) ..... ........... 11 2-2 Recursive Nature of Decomposition...approach: 1) Identify needs & requirements for IAT. 2) Develop IAT conceptual framework. 3) Validate IAT methods. 4) Develop applications materials. To

  19. Benchmarking Supplier Development: An Empirical Case Study of Validating a Framework to Improve Buyer-Supplier Relationship

    Directory of Open Access Journals (Sweden)

    Shahzad Khuram

    2016-03-01

    Full Text Available In today’s dynamic business environment, firms are required to utilize efficiently and effectively all the useful resources to gain competitive advantage. Supplier development has evolved as an important strategic instrument to improve buyer supplier relationships. For that reason, this study focuses on providing the strategic significance of supplier development approaches to improve business relationships. By using qualitative research method, an integrated framework of supplier development and buyer-supplier relationship development has been tested and validated in a Finnish case company to provide empirical evidence. It particularly investigates how supplier development approaches can develop buyer-supplier relationships. The study present a set of propositions that identify significant supplier development approaches critical for the development of buyer-supplier relationships and develop a theoretical framework that specifies how these different supplier development approaches support in order to strengthen the relationships. The results are produced from an in-depth case study by implementing the proposed research framework. The findings reveal that supplier development strategies i.e., supplier incentives and direct involvements strongly effect in developing buyer-supplier relationships. Further research may focus on considering in-depth investigation of trust and communication factors along with propositions developed in the study to find out general applicability in dynamic business environment. Proposed integrated framework along with propositions is a unique combination of useful solutions for tactical and strategic management’s decision making and also valid for academic researchers to develop supplier development theories.

  20. Vitamin D Dietary Intake Questionnaire Validation Conducted among Young Polish Women

    Science.gov (United States)

    Głąbska, Dominika; Guzek, Dominika; Sidor, Patrycja; Włodarek, Dariusz

    2016-01-01

    Due to inadequate intake of Vitamin D, identification of individuals characterised by the highest risk of deficiencies is one of the more crucial tasks for public health. The aim of the presented study was to assess the validity and reproducibility of the designed Vitamin D dietary intake questionnaire based on food frequency assessment—VIDEO-FFQ (VItamin D Estimation Only—Food Frequency Questionnaire) in a group of Polish women aged 20–30 years. Seventy-five participants kept a three-day dietary record and filled out the VIDEO-FFQ twice (immediately after the three-day dietary record and after six weeks). The assessment of validity and reproducibility was conducted by verifying standard errors of estimation, median differences, and percentages of individuals classified into tertiles, correlations and Bland-Altman plots. The Vitamin D intake for the majority of the surveyed women was inadequate as over 85% of them were characterised by values of intake lower than 5.0 μg per day. The results allowed concluding that a high accuracy of the VIDEO-FFQ was achieved. The required Bland-Altman index values lower than 5.0% were obtained, confirming satisfactory validity and reproducibility. The VIDEO-FFQ may be deemed a convenient practical tool for the estimation of Vitamin D intake in young women. PMID:26742070

  1. Validation of minor species of the MIPAS2D database

    Directory of Open Access Journals (Sweden)

    Enzo Papandrea

    2014-01-01

    Full Text Available The MIPAS2D [Dinelli et al., 2010] database has been developed applying the tomographic analysis technique GMTR [Carlotti et al., 2001] to measurements acquired in the nominal observation mode of the complete MIPAS (Michelson Interferometer for Passive Atmosphere Sounding [Fischer et al., 2008] mission. […

  2. Virtual Prototyping and Validation of Cpps within a New Software Framework

    Directory of Open Access Journals (Sweden)

    Sebastian Neumeyer

    2017-02-01

    Full Text Available As a result of the growing demand for highly customized and individual products, companies need to enable flexible and intelligent manufacturing. Cyber-physical production systems (CPPS will act autonomously in the future in an interlinked production and enable such flexibility. However, German mid-sized plant manufacturers rarely use virtual technologies for design and validation in order to design CPPS. The research project Virtual Commissioning with Smart Hybrid Prototyping (VIB-SHP investigated the usage of virtual technologies for manufacturing systems and CPPS design. Aspects of asynchronous communicating, intelligent- and autonomous-acting production equipment in an immersive validation environment, have been investigated. To enable manufacturing system designers to validate CPPS, a software framework for virtual prototyping has been developed. A mechatronic construction kit for production system design integrates discipline-specific models and manages them in a product lifecycle management (PLM solution. With this construction kit manufacturing designers are able to apply virtual technologies and the validation of communication processes with the help of behavior models. The presented approach resolves the sequential design process for the development of mechanical, electrical, and software elements and ensures the consistency of these models. With the help of a bill of material (BOM- and signal-based alignment of the discipline-specific models in an integrated mechatronic product model, the communication of the design status and changes are improved. The re-use of already-specified and -designed modules enable quick behavior modeling, code evaluation, as well as interaction with the virtualized assembly system in an immersive environment.

  3. Experimental validation of Villain's conjecture about magnetic ordering in quasi-1D helimagnets

    International Nuclear Information System (INIS)

    Cinti, F.; Rettori, A.; Pini, M.G.; Mariani, M.; Micotti, E.; Lascialfari, A.; Papinutto, N.; Amato, A.; Caneschi, A.; Gatteschi, D.; Affronte, M.

    2010-01-01

    Low-temperature magnetic susceptibility, zero-field muon spin resonance and specific heat measurements have been performed in the quasi-one-dimensional (1D) molecular helimagnetic compound Gd(hfac) 3 NITEt. The specific heat presents two anomalies at T 0 =2.19(2)K and T N =1.88(2)K, while susceptibility and zero-field muon spin resonance show anomalies only at T N =1.88(2)K. The results suggest an experimental validation of Villain's conjecture of a two-step magnetic ordering in quasi-1D XY helimagnets: the paramagnetic phase and the helical spin solid phases are separated by a chiral spin liquid, where translational invariance is broken without violation of rotational invariance.

  4. Enhancing the usability of seasonal to decadal (S2D) climate information - an evidence-based framework for the identification and assessment of sector-specific vulnerabilities

    Science.gov (United States)

    Funk, Daniel

    2016-04-01

    The successful provision of from seasonal to decadal (S2D) climate service products to sector-specific users is dependent on specific problem characteristics and individual user needs and decision-making processes. Climate information requires an impact on decision making to have any value (Rodwell and Doblas-Reyes, 2006). For that reason the knowledge of sector-specific vulnerabilities to S2D climate variability is very valuable information for both, climate service producers and users. In this context a concept for a vulnerability assessment framework was developed to (i) identify climate events (and especially their temporal scales) critical for sector-specific problems to assess the basic requirements for an appropriate climate-service product development; and to (ii) assess the potential impact or value of related climate information for decision-makers. The concept was developed within the EUPORIAS project (European Provision of Regional Impacts Assessments on Seasonal and Decadal Timescales) based on ten project-related case-studies from different sectors all over Europe. In the prevalent stage the framework may be useful as preliminary assessment or 'quick-scan' of the vulnerability of specific systems to climate variability in the context of S2D climate service provision. The assessment strategy of the framework is user-focused, using predominantly a bottom-up approach (vulnerability as state) but also a top-down approach (vulnerability as outcome) generally based on qualitative data (surveys, interviews, etc.) and literature research for system understanding. The starting point of analysis is a climate-sensitive 'critical situation' of the considered system which requires a decision and is defined by the user. From this basis the related 'critical climate conditions' are assessed and 'climate information needs' are derived. This mainly refers to the critical period of time of the climate event or sequence of events. The relevant period of time of problem

  5. 2D water layer enclathrated between Mn(II)-Ni(CN)4 coordination frameworks

    International Nuclear Information System (INIS)

    Ray, Ambarish; Bhowmick, Indrani; Sheldrick, William S.; Jana, Atish Dipankar; Ali, Mahammed

    2009-01-01

    A [Ni(CN) 4 ] 2- based two-dimensional Mn(II) coordination polymer {Mn(H 2 O) 2 [NiCN] 4 .4H 2 O}, in which the coordination layers are stacked on top of each other sandwiching 2D water layer of boat-shaped hexagonal water clusters has been synthesized. The complex exhibits high thermal decomposition temperature and reversible water absorption, which were clearly demonstrated by thermal and PXRD studies on the parent and rehydrated complex after dehydration. - Abstract: A coordination polymer, {Mn(H 2 O) 2 [NiCN] 4 .4H 2 O} n , showed that the coordination layers are stacked on top of each other sandwiching 2D ice layer of boat-shaped hexagonal water clusters . Display Omitted

  6. Achieving energy efficiency in LTE with joint D2D communications and green networking techniques

    KAUST Repository

    Yaacoub, Elias E.

    2013-07-01

    In this paper, the joint operation of cooperative device-to-device (D2D) communications and green cellular communications is investigated. An efficient approach for grouping mobile terminals (MTs) into cooperative clusters is described. In each cluster, MTs cooperate via D2D communications to share content of common interest. Furthermore, an energy-efficient technique for putting BSs in sleep mode in an LTE cellular network is presented. Finally, both methods are combined in order to ensure green communications for both the users\\' MTs and the operator\\'s BSs. The studied methods are investigated in the framework of OFDMA-based state-of-the-art LTE cellular networks, while taking into account intercell interference and resource allocation. © 2013 IEEE.

  7. GPU accelerated generation of digitally reconstructed radiographs for 2-D/3-D image registration.

    Science.gov (United States)

    Dorgham, Osama M; Laycock, Stephen D; Fisher, Mark H

    2012-09-01

    Recent advances in programming languages for graphics processing units (GPUs) provide developers with a convenient way of implementing applications which can be executed on the CPU and GPU interchangeably. GPUs are becoming relatively cheap, powerful, and widely available hardware components, which can be used to perform intensive calculations. The last decade of hardware performance developments shows that GPU-based computation is progressing significantly faster than CPU-based computation, particularly if one considers the execution of highly parallelisable algorithms. Future predictions illustrate that this trend is likely to continue. In this paper, we introduce a way of accelerating 2-D/3-D image registration by developing a hybrid system which executes on the CPU and utilizes the GPU for parallelizing the generation of digitally reconstructed radiographs (DRRs). Based on the advancements of the GPU over the CPU, it is timely to exploit the benefits of many-core GPU technology by developing algorithms for DRR generation. Although some previous work has investigated the rendering of DRRs using the GPU, this paper investigates approximations which reduce the computational overhead while still maintaining a quality consistent with that needed for 2-D/3-D registration with sufficient accuracy to be clinically acceptable in certain applications of radiation oncology. Furthermore, by comparing implementations of 2-D/3-D registration on the CPU and GPU, we investigate current performance and propose an optimal framework for PC implementations addressing the rigid registration problem. Using this framework, we are able to render DRR images from a 256×256×133 CT volume in ~24 ms using an NVidia GeForce 8800 GTX and in ~2 ms using NVidia GeForce GTX 580. In addition to applications requiring fast automatic patient setup, these levels of performance suggest image-guided radiation therapy at video frame rates is technically feasible using relatively low cost PC

  8. A Validation Study of an Interviewer-Administered Short Food Frequency Questionnaire in Assessing Dietary Vitamin D and Calcium Intake in Swedish Children.

    Science.gov (United States)

    Söderberg, Lotta; Lind, Torbjörn; Karlsland Åkeson, Pia; Sandström, Ann-Kristin; Hernell, Olle; Öhlund, Inger

    2017-06-30

    Vitamin D and calcium are essential nutrients with a range of biological effects of public health relevance. This study aimed to validate a short food frequency questionnaire (SFFQ) against a three-day food record (3D record), assessing the intake of vitamin D and calcium in Swedish children during wintertime. In a double-blinded, randomized food-based intervention study on the effect of feeding different daily doses of vitamin D supplement to 5-7-year-old children ( n = 85), 79 (93%) participants completed SFFQ1 at baseline and SFFQ2 after the intervention, and 72 were informed to fill in a 3D record. The 28 (39%) children who completed the 3D record were included in this validation study. The baseline level of serum-25 hydroxy vitamin D [S-25(OH)D] was used as a biomarker. The correlation between all three instruments were moderate to strong. SFFQ2 and the 3D record correlated moderately to S-25(OH)D. Bland-Altman analysis showed that SFFQ2 overestimated vitamin D intake by on average 0.6 μg/day, (limits of agreement (LOA) 5.7 and -4.6 μg/day), whereas the intake of calcium was underestimated by on average 29 mg/day, (LOA 808 and -865 mg/day). Finally, the validity coefficient calculated for vitamin D using the method of triad was high (0.75). In conclusion, this SFFQ, assessed by a dietician, is a valid tool to assess dietary vitamin D and calcium intake in groups of young children.

  9. Validation of a Culturally Appropriate Social Capital Framework to Explore Health Conditions in Canadian First Nations Communities

    Directory of Open Access Journals (Sweden)

    Brenda Elias

    2011-05-01

    Full Text Available An earlier study of our research group formulated a conceptual framework of social capital for First Nation communities and developed a culturally appropriate instrument for its measurement. We tested this instrument further with the Manitoba (Canada First Nations Regional Health Survey, 2003. Using data from this survey, we investigated the bonding dimension of the social capital conceptual framework, with a total sample of 2,765 First Nations individuals living in 24 Manitoba First Nations communities. Twenty seven Likert-scale survey questions measured aspects of bonding social capital, socially-invested resources, ethos,and networks. Validation analyses included an evaluation of internal consistency, factor analyses to explore how well the items clustered together into the components of the social capital framework, and the ability of the items to discriminate across the communities represented in the sample. Cronbach’s Alpha was computed on the 27 scale items, producing an Alpha of 0.84 indicating high internal consistency. The factor analyses produced five distinct factors with a total explained variance of 54.3%. Lastly, a one-way analysis of variancerun by community produced highly significant F-ratios between the groups on all twenty-seven bonding items. The culturally-sensitive items included in the social capital framework were found to be an appropriate tool to measure bonding aspects among Manitoba First Nations communities. Research and policy implications are discussed.

  10. Coordination Polymers and Metal Organic Frameworks Derived from 1,2,4-Triazole Amino Acid Linkers

    Directory of Open Access Journals (Sweden)

    Yann Garcia

    2011-10-01

    Full Text Available The perceptible appearance of biomolecules as prospective building blocks in the architecture of coordination polymers (CPs and metal-organic frameworks (MOFs are redolent of their inclusion in the synthon/tecton library of reticular chemistry. In this frame, for the first time a synthetic strategy has been established for amine derivatization in amino acids into 1,2,4-triazoles. A set of novel 1,2,4-triazole derivatized amino acids were introduced as superlative precursors in the design of 1D coordination polymers, 2D chiral helicates and 3D metal-organic frameworks. Applications associated with these compounds are diverse and include gas adsorption-porosity partitioning, soft sacrificial matrix for morphology and phase selective cadmium oxide synthesis, FeII spin crossover materials, zinc-b-lactamases inhibitors, logistics for generation of chiral/non-centrosymmetric networks; and thus led to a foundation of a new family of functional CPs and MOFs that are reviewed in this invited contribution.

  11. H-Ransac a Hybrid Point Cloud Segmentation Combining 2d and 3d Data

    Science.gov (United States)

    Adam, A.; Chatzilari, E.; Nikolopoulos, S.; Kompatsiaris, I.

    2018-05-01

    In this paper, we present a novel 3D segmentation approach operating on point clouds generated from overlapping images. The aim of the proposed hybrid approach is to effectively segment co-planar objects, by leveraging the structural information originating from the 3D point cloud and the visual information from the 2D images, without resorting to learning based procedures. More specifically, the proposed hybrid approach, H-RANSAC, is an extension of the well-known RANSAC plane-fitting algorithm, incorporating an additional consistency criterion based on the results of 2D segmentation. Our expectation that the integration of 2D data into 3D segmentation will achieve more accurate results, is validated experimentally in the domain of 3D city models. Results show that HRANSAC can successfully delineate building components like main facades and windows, and provide more accurate segmentation results compared to the typical RANSAC plane-fitting algorithm.

  12. HCI^2 Framework: A software framework for multimodal human-computer interaction systems

    NARCIS (Netherlands)

    Shen, Jie; Pantic, Maja

    2013-01-01

    This paper presents a novel software framework for the development and research in the area of multimodal human-computer interface (MHCI) systems. The proposed software framework, which is called the HCI∧2 Framework, is built upon publish/subscribe (P/S) architecture. It implements a

  13. Kalman Filter for Generalized 2-D Roesser Models

    Institute of Scientific and Technical Information of China (English)

    SHENG Mei; ZOU Yun

    2007-01-01

    The design problem of the state filter for the generalized stochastic 2-D Roesser models, which appears when both the state and measurement are simultaneously subjected to the interference from white noise, is discussed. The wellknown Kalman filter design is extended to the generalized 2-D Roesser models. Based on the method of "scanning line by line", the filtering problem of generalized 2-D Roesser models with mode-energy reconstruction is solved. The formula of the optimal filtering, which minimizes the variance of the estimation error of the state vectors, is derived. The validity of the designed filter is verified by the calculation steps and the examples are introduced.

  14. [Criterion Validity of the German Version of the CES-D in the General Population].

    Science.gov (United States)

    Jahn, Rebecca; Baumgartner, Josef S; van den Nest, Miriam; Friedrich, Fabian; Alexandrowicz, Rainer W; Wancata, Johannes

    2018-04-17

    The "Center of Epidemiologic Studies - Depression scale" (CES-D) is a well-known screening tool for depression. Until now the criterion validity of the German version of the CES-D was not investigated in a sample of the adult general population. 508 study participants of the Austrian general population completed the CES-D. ICD-10 diagnoses were established by using the Schedules for Clinical Assessment in Neuropsychiatry (SCAN). Receiver Operating Characteristics (ROC) analysis was conducted. Possible gender differences were explored. Overall discriminating performance of the CES-D was sufficient (ROC-AUC 0,836). Using the traditional cut-off values of 15/16 and 21/22 respectively the sensitivity was 43.2 % and 32.4 %, respectively. The cut-off value developed on the basis of our sample was 9/10 with a sensitivity of 81.1 % und a specificity of 74.3 %. There were no significant gender differences. This is the first study investigating the criterion validity of the German version of the CES-D in the general population. The optimal cut-off values yielded sufficient sensitivity and specificity, comparable to the values of other screening tools. © Georg Thieme Verlag KG Stuttgart · New York.

  15. A Unified 3D Mesh Segmentation Framework Based on Markov Random Field

    OpenAIRE

    Z.F. Shi; L.Y. Lu; D. Le; X.M. Niu

    2012-01-01

    3D Mesh segmentation has become an important research field in computer graphics during the past decades. Many geometry based and semantic oriented approaches for 3D mesh segmentation has been presented. In this paper, we present a definition of mesh segmentation according to labeling problem. Inspired by the Markov Random Field (MRF) based image segmentation, we propose a new framework of 3D mesh segmentation based on MRF and use graph cuts to solve it. Any features of 3D mesh can be integra...

  16. Automated image alignment for 2D gel electrophoresis in a high-throughput proteomics pipeline.

    Science.gov (United States)

    Dowsey, Andrew W; Dunn, Michael J; Yang, Guang-Zhong

    2008-04-01

    The quest for high-throughput proteomics has revealed a number of challenges in recent years. Whilst substantial improvements in automated protein separation with liquid chromatography and mass spectrometry (LC/MS), aka 'shotgun' proteomics, have been achieved, large-scale open initiatives such as the Human Proteome Organization (HUPO) Brain Proteome Project have shown that maximal proteome coverage is only possible when LC/MS is complemented by 2D gel electrophoresis (2-DE) studies. Moreover, both separation methods require automated alignment and differential analysis to relieve the bioinformatics bottleneck and so make high-throughput protein biomarker discovery a reality. The purpose of this article is to describe a fully automatic image alignment framework for the integration of 2-DE into a high-throughput differential expression proteomics pipeline. The proposed method is based on robust automated image normalization (RAIN) to circumvent the drawbacks of traditional approaches. These use symbolic representation at the very early stages of the analysis, which introduces persistent errors due to inaccuracies in modelling and alignment. In RAIN, a third-order volume-invariant B-spline model is incorporated into a multi-resolution schema to correct for geometric and expression inhomogeneity at multiple scales. The normalized images can then be compared directly in the image domain for quantitative differential analysis. Through evaluation against an existing state-of-the-art method on real and synthetically warped 2D gels, the proposed analysis framework demonstrates substantial improvements in matching accuracy and differential sensitivity. High-throughput analysis is established through an accelerated GPGPU (general purpose computation on graphics cards) implementation. Supplementary material, software and images used in the validation are available at http://www.proteomegrid.org/rain/.

  17. Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D-3D image registration.

    Science.gov (United States)

    de Bruin, P W; Kaptein, B L; Stoel, B C; Reiber, J H C; Rozing, P M; Valstar, E R

    2008-01-01

    Image-based Roentgen stereophotogrammetric analysis (IBRSA) integrates 2D-3D image registration and conventional RSA. Instead of radiopaque RSA bone markers, IBRSA uses 3D CT data, from which digitally reconstructed radiographs (DRRs) are generated. Using 2D-3D image registration, the 3D pose of the CT is iteratively adjusted such that the generated DRRs resemble the 2D RSA images as closely as possible, according to an image matching metric. Effectively, by registering all 2D follow-up moments to the same 3D CT, the CT volume functions as common ground. In two experiments, using RSA and using a micromanipulator as gold standard, IBRSA has been validated on cadaveric and sawbone scapula radiographs, and good matching results have been achieved. The accuracy was: |mu |RSA but higher than in vivo standard RSA. Because IBRSA does not require radiopaque markers, it adds functionality to the RSA method by opening new directions and possibilities for research, such as dynamic analyses using fluoroscopy on subjects without markers and computer navigation applications.

  18. Talk2Me: A Framework for Device–to–Device Augmented Reality Social Network

    DEFF Research Database (Denmark)

    Shu, Jiayu; Kosta, Sokol; Zheng, Rui

    2018-01-01

    , an augmented reality social network framework that enables users to disseminate information in a distributed way and view others’ information instantly. Talk2Me advertises users’ messages, together with their face–signature, to every nearby device in a Device–to–Device fashion. When a user looks at nearby...... persons through her camera–enabled wearable devices (e.g., Google Glass), the framework automatically extracts the face–signature of the person of interest, compares it with the previously captured signatures, and presents the information shared by this person to the user. We design and implement Talk2Me...... a novel face recognition algorithm for this specific scenario with a small number of face features and limited computing capability. Evaluation results of the prototype with real users and extensive simulations validate the performance and usability of our design, showing the potentials of the augmented...

  19. Self and transport diffusivity of CO2 in the metal-organic framework MIL-47(V) explored by quasi-elastic neutron scattering experiments and molecular dynamics simulations.

    Science.gov (United States)

    Salles, Fabrice; Jobic, Hervé; Devic, Thomas; Llewellyn, Philip L; Serre, Christian; Férey, Gérard; Maurin, Guillaume

    2010-01-26

    Quasi-elastic neutron scattering measurements are combined with molecular dynamics simulations to determine the self-diffusivity, corrected diffusivity, and transport diffusivity of CO(2) in the metal-organic framework MIL-47(V) (MIL = Materials Institut Lavoisier) over a wide range of loading. The force field used for describing the host/guest interactions is first validated on the thermodynamics of the MIL-47(V)/CO(2) system, prior to being transferred to the investigations of the dynamics. A decreasing profile is then deduced for D(s) and D(o) whereas D(t) presents a non monotonous evolution with a slight decrease at low loading followed by a sharp increase at higher loading. Such decrease of D(t) which has never been evidenced in any microporous systems comes from the atypical evolution of the thermodynamic correction factor that reaches values below 1 at low loading. This implies that, due to intermolecular interactions, the CO(2) molecules in MIL-47(V) do not behave like an ideal gas. Further, molecular simulations enabled us to elucidate unambiguously a 3D diffusion mechanism within the pores of MIL-47(V).

  20. A conservative scheme for 2D and 3D adaptive semi-Lagrangian advection

    OpenAIRE

    Behrens, Jörn; Mentrup, Lars

    2005-01-01

    This article describes a 2D and 3D adaptive and mass conservingsemi-Lagrangian advection scheme for atmospheric transport problems. Fromthe integral form of the conservation law we derive a semi-Lagrangian schemebased on conservation of mass along trajectories. The mapping of mass fromthe old (adaptively refined and possibly different) grid to the upstream controlvolume is performed by a mass packet based scheme, essentially consistingof a sub-grid discretization. We validate the new adaptive...

  1. Positional isomerism-driven two 3D pillar-layered metal-organic frameworks: Syntheses, topological structures and photoluminescence properties

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yayong; Zhao, Siwei; Ma, Haoran; Han, Yi; Liu, Kang; Wang, Lei, E-mail: inorchemwl@126.com

    2016-06-15

    Two novel three-dimensional (3D) pillar-layered metal-organic frameworks (MOFs), namely [Zn{sub 2}(μ{sub 2}-OH)(boaba)(1,4-bmimb)]{sub n} (1) and {[Zn_5K_2(μ_2-H_2O)_2(boaba)_4(1,2-bmimb)_2(H_2O)_2]·H_2O}{sub n} (2), were prepared by hydrothermal reactions (H{sub 3}boaba=3,5-bis-oxyacetate-benzoic acid; 1,4-bmimb=1,4-bis((2-methyl-1H-imidazol-1-yl)methyl)benzene; 1,2-bmimb =1,2-bis((2-methyl-1H-imidazol-1-yl)methyl)benzene). Notably, 1 exhibits a (3,5)-connected binodal (6{sup 3})(6{sup 9}·8)-gra net with binuclear [Zn{sub 2}(μ{sub 2}-OH)(COO)]{sup 2+} clusters, while 2 shows a novel (4,4,5,9)-connected 4-nodal net constructed from the unique Zn(II)-K(I) heterometal rod-like substructures. The results indicate that the disposition of the 2-methylimidazolyl groups of bis(imidazole) ligands have a significant effect on structural diversity. Moreover, the photoluminescence properties of 1 and 2 have been investigated. - Graphical abstract: Two novel 3D pillar-layered metal-organic coordination networks with aromatic multicarboxylate anion and bis(imidazole) ligands have been synthesized and structurally characterized. Display Omitted - Highlights: • It is rarely reported that metal-organic frameworks prepared with 3,5-bis-oxyacetate-benzoic acid. • Two metal-organic frameworks based on positional isomeric ligands were synthesized and structurally characterized. • Compond 1 displays unique (3,5)-connected binodal gra topology. • Compound 2 exhibits (4,4,5,9)-connected 4-nodal topology based on the Zn(II)-K(I) heterometal rod-like substructures. • The photoluminescence properties of compound 1 and 2 have been investigated.

  2. Analysis results from the Los Alamos 2D/3D program

    International Nuclear Information System (INIS)

    Boyack, B.E.; Cappiello, M.W.; Harmony, S.C.; Shire, P.R.; Siebe, D.A.

    1987-01-01

    Los Alamos National Laboratory is a participant in the 2D/3D program. Activities conducted at Los Alamos National Laboratory in support of 2D/3D program goals include analysis support of facility design, construction, and operation; provision of boundary and initial conditions for test-facility operations based on analysis of pressurized water reactors; performance of pretest and posttest predictions and analyses; and use of experimental results to validate and assess the single- and multi-dimensional, nonequilibrium features in the Transient Reactor Analysis Code (TRAC). During fiscal year 1987, Los Alamos conducted analytical assessment activities using data from the Slab Core Test Facility, The Cylindrical Core Test Facility, and the Upper Plenum Test Facility. Finally, Los Alamos continued work to provide TRAC improvements. In this paper, Los Alamos activities during fiscal year 1987 will be summarized; several significant accomplishments will be described in more detail to illustrate the work activities at Los Alamos

  3. Supersymmetric D2 anti-D2 Strings

    OpenAIRE

    Bak, Dongsu; Ohta, Nobuyoshi

    2001-01-01

    We consider the flat supersymmetric D2 and anti-D2 system, which follows from ordinary noncommutative D2 anti-D2 branes by turning on an appropriate worldvolume electric field describing dissolved fundamental strings. We study the strings stretched between D2 and anti-D2 branes and show explicitly that the would-be tachyonic states become massless. We compute the string spectrum and clarify the induced noncommutativity on the worldvolume. The results are compared with the matrix theory descri...

  4. Machinability of IPS Empress 2 framework ceramic.

    Science.gov (United States)

    Schmidt, C; Weigl, P

    2000-01-01

    Using ceramic materials for an automatic production of ceramic dentures by CAD/CAM is a challenge, because many technological, medical, and optical demands must be considered. The IPS Empress 2 framework ceramic meets most of them. This study shows the possibilities for machining this ceramic with economical parameters. The long life-time requirement for ceramic dentures requires a ductile machined surface to avoid the well-known subsurface damages of brittle materials caused by machining. Slow and rapid damage propagation begins at break outs and cracks, and limits life-time significantly. Therefore, ductile machined surfaces are an important demand for machine dental ceramics. The machining tests were performed with various parameters such as tool grain size and feed speed. Denture ceramics were machined by jig grinding on a 5-axis CNC milling machine (Maho HGF 500) with a high-speed spindle up to 120,000 rpm. The results of the wear test indicate low tool wear. With one tool, you can machine eight occlusal surfaces including roughing and finishing. One occlusal surface takes about 60 min machining time. Recommended parameters for roughing are middle diamond grain size (D107), cutting speed v(c) = 4.7 m/s, feed speed v(ft) = 1000 mm/min, depth of cut a(e) = 0.06 mm, width of contact a(p) = 0.8 mm, and for finishing ultra fine diamond grain size (D46), cutting speed v(c) = 4.7 m/s, feed speed v(ft) = 100 mm/min, depth of cut a(e) = 0.02 mm, width of contact a(p) = 0.8 mm. The results of the machining tests give a reference for using IPS Empress(R) 2 framework ceramic in CAD/CAM systems. Copyright 2000 John Wiley & Sons, Inc.

  5. Comparison of 2-D and 3-D estimates of placental volume in early pregnancy.

    Science.gov (United States)

    Aye, Christina Y L; Stevenson, Gordon N; Impey, Lawrence; Collins, Sally L

    2015-03-01

    Ultrasound estimation of placental volume (PlaV) between 11 and 13 wk has been proposed as part of a screening test for small-for-gestational-age babies. A semi-automated 3-D technique, validated against the gold standard of manual delineation, has been found at this stage of gestation to predict small-for-gestational-age at term. Recently, when used in the third trimester, an estimate obtained using a 2-D technique was found to correlate with placental weight at delivery. Given its greater simplicity, the 2-D technique might be more useful as part of an early screening test. We investigated if the two techniques produced similar results when used in the first trimester. The correlation between PlaV values calculated by the two different techniques was assessed in 139 first-trimester placentas. The agreement on PlaV and derived "standardized placental volume," a dimensionless index correcting for gestational age, was explored with the Mann-Whitney test and Bland-Altman plots. Placentas were categorized into five different shape subtypes, and a subgroup analysis was performed. Agreement was poor for both PlaV and standardized PlaV (p < 0.001 and p < 0.001), with the 2-D technique yielding larger estimates for both indices compared with the 3-D method. The mean difference in standardized PlaV values between the two methods was 0.007 (95% confidence interval: 0.006-0.009). The best agreement was found for regular rectangle-shaped placentas (p = 0.438 and p = 0.408). The poor correlation between the 2-D and 3-D techniques may result from the heterogeneity of placental morphology at this stage of gestation. In early gestation, the simpler 2-D estimates of PlaV do not correlate strongly with those obtained with the validated 3-D technique. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Assembly of tin oxide/graphene nanosheets into 3D hierarchical frameworks for high-performance lithium storage.

    Science.gov (United States)

    Huang, Yanshan; Wu, Dongqing; Han, Sheng; Li, Shuang; Xiao, Li; Zhang, Fan; Feng, Xinliang

    2013-08-01

    3D hierarchical tin oxide/graphene frameworks (SnO2 /GFs) were built up by the in situ synthesis of 2D SnO2 /graphene nanosheets followed by hydrothermal assembly. These SnO2 /GFs exhibited a 3D hierarchical porous architecture with mesopores (≈3 nm), macropores (3-6 μm), and a large surface area (244 m(2) g(-1) ), which not only effectively prevented the agglomeration of SnO2 nanoparticles, but also facilitated fast ion and electron transport in 3D pathways. As a consequence, the SnO2 /GFs exhibited a high capacity of 830 mAh g(-1) for up to 70 charge-discharge cycles at 100 mA g(-1) . Even at a high current density of 500 mA g(-1) , a reversible capacity of 621 mAh g(-1) could be maintained for SnO2 /GFs with excellent cycling stability. Such performance is superior to that of previously reported SnO2 /graphene and other SnO2 /carbon composites with similar weight contents of SnO2 . Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. A unique 3D ultramicroporous triptycene-based polyimide framework for efficient gas sorption applications

    KAUST Repository

    Ghanem, Bader

    2016-10-03

    A novel 3D ultramicroporous triptycene-based polyimide framework with high surface area (1050 m2 g−1) and thermal stability was synthesized. It exhibits relatively high CO2 (3.4 mmol g−1 at 273 K and 1 bar), H2 (7 mmol g−1 at 77 K and 1 bar), and olefin sorption capacity, good CO2/N2 (45) and CO2/CH4 (9.6) selectivity at 273 K and 1 bar, as well as promising C2H4/CH4 and C3H6/CH4 selectivities at 298 K, making it a potential candidate for CO2 capture, H2 storage, and hydrocarbon gas separation applications.

  8. A unique 3D ultramicroporous triptycene-based polyimide framework for efficient gas sorption applications

    KAUST Repository

    Ghanem, Bader; Belmabkhout, Youssef; Wang, Yingge; Zhao, Yunfeng; Han, Yu; Eddaoudi, Mohamed; Pinnau, Ingo

    2016-01-01

    A novel 3D ultramicroporous triptycene-based polyimide framework with high surface area (1050 m2 g−1) and thermal stability was synthesized. It exhibits relatively high CO2 (3.4 mmol g−1 at 273 K and 1 bar), H2 (7 mmol g−1 at 77 K and 1 bar), and olefin sorption capacity, good CO2/N2 (45) and CO2/CH4 (9.6) selectivity at 273 K and 1 bar, as well as promising C2H4/CH4 and C3H6/CH4 selectivities at 298 K, making it a potential candidate for CO2 capture, H2 storage, and hydrocarbon gas separation applications.

  9. Vital analysis: field validation of a framework for annotating biological signals of first responders in action.

    Science.gov (United States)

    Gomes, P; Lopes, B; Coimbra, M

    2012-01-01

    First responders are professionals that are exposed to extreme stress and fatigue during extended periods of time. That is why it is necessary to research and develop technological solutions based on wearable sensors that can continuously monitor the health of these professionals in action, namely their stress and fatigue levels. In this paper we present the Vital Analysis smartphone-based framework, integrated into the broader Vital Responder project, that allows the annotation and contextualization of the signals collected during real action. After a contextual study we have implemented and deployed this framework in a firefighter team with 5 elements, from where we have collected over 3300 hours of annotations during 174 days, covering 382 different events. Results are analysed and discussed, validating the framework as a useful and usable tool for annotating biological signals of first responders in action.

  10. The EQ-5D (Euroqol is a valid generic instrument for measuring quality of life in patients with dyspepsia

    Directory of Open Access Journals (Sweden)

    Goh Khean-Lee

    2009-03-01

    Full Text Available Abstract Background There is little information of the validity of generic instruments in measuring health-related quality of life (HRQOL in patients with dyspepsia. We aimed to assess the reliability and validity of the EQ-5D, a brief and simple instrument, in measuring HRQOL in adult patients with dyspepsia. Methods Consecutive adults with dyspepsia attending the Gastroenterology clinic in a tertiary referral center were interviewed with the EQ-5D (both English and Malay versions, the short-form Nepean Dyspepsia Index (SF-NDI, the SF-36 and Leeds Dyspepsia Questionnaire (LDQ. Known-groups and convergent construct validity were investigated by testing hypotheses at attribute and overall levels. A repeat telephone interview was conducted 2 weeks later to assess test-retest reliability. Results A total of 113 patients (mean (SD age: 53.7 (14 years; 49.5% male; 24.8% Malays, 37.2% Chinese; 70.8% functional dyspepsia were recruited. Response rate was 100% with nil missing data. Known-groups validation revealed 20/26 hypotheses fulfillment. Patients with more severe dyspepsia reported more problems with their usual activity (p = 0.07 and pain (p = 0.06 and demonstrated lower median VAS scores (60 vs 70, p = 0.002 and EQ-5D utility scores (0.72 vs 0.78, p = 0.002. Those reporting problems in various EQ-5D dimensions had significantly lower scores in relevant SF-36 and SF-NDI dimensions. The overall EQ-5D utility score also demonstrated good correlation with the SF-36 summary physical and mental scores and the SF-NDI total score. Intraclass correlation coefficient for test-retest reliability was 0.66 (95% CI = 0.55 – 0.76. Conclusion The EQ-5D is an acceptable, valid and reliable generic instrument for measuring HRQOL in adult patients with dyspepsia.

  11. The signaling pathway of dopamine D2 receptor (D2R) activation using normal mode analysis (NMA) and the construction of pharmacophore models for D2R ligands.

    Science.gov (United States)

    Salmas, Ramin Ekhteiari; Stein, Matthias; Yurtsever, Mine; Seeman, Philip; Erol, Ismail; Mestanoglu, Mert; Durdagi, Serdar

    2017-07-01

    G-protein-coupled receptors (GPCRs) are targets of more than 30% of marketed drugs. Investigation on the GPCRs may shed light on upcoming drug design studies. In the present study, we performed a combination of receptor- and ligand-based analysis targeting the dopamine D2 receptor (D2R). The signaling pathway of D2R activation and the construction of universal pharmacophore models for D2R ligands were also studied. The key amino acids, which contributed to the regular activation of the D2R, were in detail investigated by means of normal mode analysis (NMA). A derived cross-correlation matrix provided us an understanding of the degree of pair residue correlations. Although negative correlations were not observed in the case of the inactive D2R state, a high degree of correlation appeared between the residues in the active state. NMA results showed that the cytoplasmic side of the TM5 plays a significant role in promoting of residue-residue correlations in the active state of D2R. Tracing motions of the amino acids Arg219, Arg220, Val223, Asn224, Lys226, and Ser228 in the position of the TM5 are found to be critical in signal transduction. Complementing the receptor-based modeling, ligand-based modeling was also performed using known D2R ligands. The top-scored pharmacophore models were found as 5-sited (AADPR.671, AADRR.1398, AAPRR.3900, and ADHRR.2864) hypotheses from PHASE modeling from a pool consisting of more than 100 initial candidates. The constructed models using 38 D2R ligands (in the training set) were validated with 15 additional test set compounds. The resulting model correctly predicted the pIC 50 values of an additional test set compounds as true unknowns.

  12. Preliminary Validation of a Parent-Child Relational Framework for Teaching Developmental Assessment to Pediatric Residents.

    Science.gov (United States)

    Regalado, Michael; Schneiderman, Janet U; Duan, Lei; Ragusa, Gisele

    A parent-child relational framework was used as a method to train pediatric residents in basic knowledge and observation skills for the assessment of child development. Components of the training framework and its preliminary validation as an alternative to milestone-based approaches are described. Pediatric residents were trained during a 4-week clinical rotation to use a semistructured interview and observe parent-child behavior during health visits using clinical criteria for historical information and observed behavior that reflect developmental change in the parent-child relationship. Clinical impressions of concern versus no concern for developmental delay were derived from parent-child relational criteria and the physical examination. A chart review yielded 330 preterm infants evaluated using this methodology at 4 and 15 months corrected age who also had standardized developmental testing at 6 and 18 months corrected age. Sensitivities and specificities were computed to examine the validity of the clinical assessment compared with standardized testing. A subset of residents who completed 50 or more assessments during the rotation was timed at the end of 4 weeks. Parent-child behavioral markers elicited from the history and/or observed during the health visit correlated highly with standardized developmental assessment. Sensitivities and specificities were 0.72/0.98 and 0.87/0.96 at 4 to 6 and 15 to 18 months, respectively. Residents completed their assessments parent-child relational framework is a potentially efficient and effective approach to training residents in the clinical knowledge and skills of child development assessment. Copyright © 2016 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  13. Application of 2D and 3D image technologies to characterise morphological attributes of grapevine clusters.

    Science.gov (United States)

    Tello, Javier; Cubero, Sergio; Blasco, José; Tardaguila, Javier; Aleixos, Nuria; Ibáñez, Javier

    2016-10-01

    Grapevine cluster morphology influences the quality and commercial value of wine and table grapes. It is routinely evaluated by subjective and inaccurate methods that do not meet the requirements set by the food industry. Novel two-dimensional (2D) and three-dimensional (3D) machine vision technologies emerge as promising tools for its automatic and fast evaluation. The automatic evaluation of cluster length, width and elongation was successfully achieved by the analysis of 2D images, significant and strong correlations with the manual methods being found (r = 0.959, 0.861 and 0.852, respectively). The classification of clusters according to their shape can be achieved by evaluating their conicity in different sections of the cluster. The geometric reconstruction of the morphological volume of the cluster from 2D features worked better than the direct 3D laser scanning system, showing a high correlation (r = 0.956) with the manual approach (water displacement method). In addition, we constructed and validated a simple linear regression model for cluster compactness estimation. It showed a high predictive capacity for both the training and validation subsets of clusters (R(2)  = 84.5 and 71.1%, respectively). The methodologies proposed in this work provide continuous and accurate data for the fast and objective characterisation of cluster morphology. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  14. Validation and applicability of the 3D core kinetics and thermal hydraulics coupled code SPARKLE

    International Nuclear Information System (INIS)

    Miyata, Manabu; Maruyama, Manabu; Ogawa, Junto; Otake, Yukihiko; Miyake, Shuhei; Tabuse, Shigehiko; Tanaka, Hirohisa

    2009-01-01

    The SPARKLE code is a coupled code system based on three individual codes whose physical models have already been verified and validated. Mitsubishi Heavy Industries (MHI) confirmed the coupling calculation, including data transfer and the total reactor coolant system (RCS) behavior of the SPARKLE code. The confirmation uses the OECD/NEA MSLB benchmark problem, which is based on Three Mile Island Unit 1 (TMI-1) nuclear power plant data. This benchmark problem has been used to verify coupled codes developed and used by many organizations. Objectives of the benchmark program are as follows. Phase 1 is to compare the results of the system transient code using point kinetics. Phase 2 is to compare the results of the coupled three-dimensional (3D) core kinetics code and 3D core thermal-hydraulics (T/H) code, and Phase 3 is to compare the results of the combined coupled system transient code, 3D core kinetics code, and 3D core T/H code as a total validation of the coupled calculation. The calculation results of the SPARKLE code indicate good agreement with other benchmark participants' results. Therefore, the SPARKLE code is validated through these benchmark problems. In anticipation of applying the SPARKLE code to licensing analyses, MHI and Japanese PWR utilities have established a safety analysis method regarding the calculation conditions such as power distributions, reactivity coefficients, and event-specific features. (author)

  15. Selective 4D modelling framework for spatial-temporal land information management system

    Science.gov (United States)

    Doulamis, Anastasios; Soile, Sofia; Doulamis, Nikolaos; Chrisouli, Christina; Grammalidis, Nikos; Dimitropoulos, Kosmas; Manesis, Charalambos; Potsiou, Chryssy; Ioannidis, Charalabos

    2015-06-01

    This paper introduces a predictive (selective) 4D modelling framework where only the spatial 3D differences are modelled at the forthcoming time instances, while regions of no significant spatial-temporal alterations remain intact. To accomplish this, initially spatial-temporal analysis is applied between 3D digital models captured at different time instances. So, the creation of dynamic change history maps is made. Change history maps indicate spatial probabilities of regions needed further 3D modelling at forthcoming instances. Thus, change history maps are good examples for a predictive assessment, that is, to localize surfaces within the objects where a high accuracy reconstruction process needs to be activated at the forthcoming time instances. The proposed 4D Land Information Management System (LIMS) is implemented using open interoperable standards based on the CityGML framework. CityGML allows the description of the semantic metadata information and the rights of the land resources. Visualization aspects are also supported to allow easy manipulation, interaction and representation of the 4D LIMS digital parcels and the respective semantic information. The open source 3DCityDB incorporating a PostgreSQL geo-database is used to manage and manipulate 3D data and their semantics. An application is made to detect the change through time of a 3D block of plots in an urban area of Athens, Greece. Starting with an accurate 3D model of the buildings in 1983, a change history map is created using automated dense image matching on aerial photos of 2010. For both time instances meshes are created and through their comparison the changes are detected.

  16. CATHARE 2 V2.5 : a fully validated CATHARE version for various applications

    International Nuclear Information System (INIS)

    Robert, M.; Farvacque, M.; Parent, M.; Faydide, B.

    2003-01-01

    The CATHARE code is devoted to best estimate calculations of thermal-hydraulic transients in nuclear reactors. The code is based on a 2-fluid 6-equation model including non-condensable gases equations and additional equations for radio-chemical components transport. It allows the coolant circuits of any reactor to be represented by assembling 1D, 0D and 3D modules. The outcome of more than 20 years of joint development effort by CEA, EDF, FRAMATOME-ANP and IRSN, is the CATHARE 2 V2.5 version, to be released at the end of 2003. The development strategy of this version was to include in one single version the functionalities and the models needed for all the various applications the CATHARE partners have to deal with, in the scope of thermal-hydraulic nuclear safety analysis. Physical assessment is a highly time consuming activity for this kind of code. The 'single version' strategy results in putting together the validation efforts required for each application, thus significantly reducing the global validation effort. It also makes the maintenance process more efficient. The main objective of CATHARE 2 V2.5 is to perform safety analyses for Pressurized Water Reactors postulated accidents or other incidents, such as primary LOCAs, SGTR, loss of RHR, secondary breaks, loss of feed-water, etc. The 3D module of CATHARE has been developed in connection with the future safety methodologies based on the 3D modelling of the vessel. The main application is the large break LOCA where significant 3D effects take place, and in particular the phenomena related to the core radial temperature profile, the 3D core quenching pattern, the bypass of the accumulator water to the break and CCFL phenomena in the down-comer during the refill phase. These effects are exemplified with a PWR large break LOCA calculation using a 3D modeling of the vessel. Another major application of this version of CATHARE is to be used without modification in the SIPA French reactor simulator. This

  17. 3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements.

    Science.gov (United States)

    Pier, Danielle B; Gholipour, Ali; Afacan, Onur; Velasco-Annis, Clemente; Clancy, Sean; Kapur, Kush; Estroff, Judy A; Warfield, Simon K

    2016-09-01

    Current diagnosis of fetal posterior fossa anomalies by sonography and conventional MRI is limited by fetal position, motion, and by two-dimensional (2D), rather than three-dimensional (3D), representation. In this study, we aimed to validate the use of a novel magnetic resonance imaging (MRI) technique, 3D super-resolution motion-corrected MRI, to image the fetal posterior fossa. From a database of pregnant women who received fetal MRIs at our institution, images of 49 normal fetal brains were reconstructed. Six measurements of the cerebellum, vermis, and pons were obtained for all cases on 2D conventional and 3D reconstructed MRI, and the agreement between the two methods was determined using concordance correlation coefficients. Concordance of axial and coronal measurements of the transcerebellar diameter was also assessed within each method. Between the two methods, the concordance of measurements was high for all six structures (P fetal motion and orthogonal slice acquisition. This technique will facilitate further study of fetal abnormalities of the posterior fossa. Copyright © 2016 by the American Society of Neuroimaging.

  18. 3D Rare earth porous coordination frameworks with formamide generated in situ syntheses: Crystal structure and down- and up-conversion luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Xue [Department of Chemistry, Capital Normal University, Beijing 100048 (China); Tian, Jing [Department of Chemistry, Capital Normal University, Beijing 100048 (China); Experiment and Teaching Resource Management Centre, Yibin University, Yibin, 644000 (China); Yang, Hong-Y.; Zhao, Kai [Department of Chemistry, Capital Normal University, Beijing 100048 (China); Li, Xia, E-mail: xiali@mail.cnu.edu.cn [Department of Chemistry, Capital Normal University, Beijing 100048 (China)

    2013-05-01

    The reaction of RE(NO)₃·6H₂O and formamide yielded the coordination polymers, [RE(HCOO)₄]⁻[NH₂CHNH₂]⁺ (RE=Y 1, Eu 2, Gd 3, Tb 4, Dy 5, Er 6, and Yb 7). They possess 3D porous frameworks with the 1D rhombic channels occupied by [NH₂CHNH₂]⁺ cations. Complexes 2 and 4 display the characteristic down-conversion emissions corresponding to ⁵D₀→⁷FJ (J=1–4) transitions of Eu(III) ion and ⁵D₄→⁷FJ (J=6–3) transitions of Tb(III) ion, respectively. Longer lifetime values of 2.128±0.002 ms (⁵D₀) for 2 and 2.132±0.002 ms (⁵D₄) for 4 have been observed. The up-conversion spectra of the Y:Yb,Er and Gd:Yb,Er codoped complexes exhibit three emission bands around 410 (⁴H9/2→⁴I15/2, blue), 518–570 (⁴S3/2, ²H11/2→⁴I15/2, green), and 655 nm (⁴F9/2→⁴I15/2, red). - Graphical Abstract: The complexes [RE(HCOO)₄]⁻[NH₂CHNH₂]⁺ possess 3D porous frameworks. Eu(III) and Tb(III) complexes show characteristic emission of Ln(III) ions. The up-conversion emission of the Y:Yb,Er and Gd:Yb,Er codoped complexes was observed. Highlights: •The reaction of RE(NO)₃·6H₂O and formamide produced complexes [RE(HCOO)₄]⁻[NH₂CHNH₂]⁺. • The complexes possess 3D frameworks with the 1D channels occupied by [NH₂CHNH₂]+ cations. • Eu(III)/Tb(III) complexes display the characteristic down-conversion emission of Ln(III) ions. • The Y:Yb,Er and Gd:Yb,Er doped complexes exhibit the up-conversion emission.

  19. Flexible 2D layered material junctions

    Science.gov (United States)

    Balabai, R.; Solomenko, A.

    2018-03-01

    Within the framework of the methods of the electron density functional and the ab initio pseudopotential, we have obtained the valence electron density spatial distribution, the densities of electron states, the widths of band gaps, the charges on combined regions, and the Coulomb potentials for graphene-based flexible 2D layered junctions, using author program complex. It is determined that the bending of the 2D layered junctions on the angle α leads to changes in the electronic properties of these junctions. In the graphene/graphane junction, there is clear charge redistribution with different signs in the regions of junctions. The presence in the heterojunctions of charge regions with different signs leads to the formation of potential barriers. The greatest potential jump is in the graphene/fluorographene junction. The greatest value of the band gap width is in the graphene/graphane junction.

  20. On the relation between 2D:4D and sex-dimorphic personality traits.

    Science.gov (United States)

    Hampson, Elizabeth; Ellis, Connie L; Tenk, Christine M

    2008-02-01

    Several personality traits, including aggressiveness and sensation seeking, have been hypothesized to be influenced by prenatal androgen exposure, though evidence for this proposition is limited. We investigated whether individual differences in aggressiveness, sensation seeking, and several prosocial personality traits can be predicted from differences in the 2D:4D digit ratio, a putative marker of prenatal androgen activity. A total of 164 undergraduates (87 men, 77 women) completed self-report measures of physical and verbal aggression, as well as a standardized measure of sensation seeking, and five scales to assess empathy, nurturance, expressivity/femininity, instrumentality/masculinity, and assertiveness. Two sex-dimorphic tests of spatial ability also were included. Men had a lower 2D:4D ratio than women, confirming the typical sex difference in digit proportions. Significant sex differences were observed on 10 of the 11 personality scales purported to show sex differences and on both tests of spatial ability. The 2D:4D ratio was a significant predictor of scores on three of the four aggression subscales, total aggression, thrill and adventure seeking, and total sensation-seeking, in the sample as a whole and in women. In men, correlations with 2D:4D were significant only for total sensation-seeking and verbal aggression. In both sexes, lower 2D:4D ratios were associated with increased aggressiveness and sensation seeking. For the spatial tests, there was no evidence of any association with 2D:4D in either men or women. The 2D:4D digit ratio may be a valid, though weak, predictor of selective sex-dependent traits that are sensitive to testosterone.

  1. Validation of Dietary Vitamin D Intake from Two Food Frequency Questionnaires, Using Food Records and the Biomarker 25-Hydroxyvitamin D among Pregnant Women.

    Science.gov (United States)

    Bärebring, Linnea; Amberntsson, Anna; Winkvist, Anna; Augustin, Hanna

    2018-06-08

    Our objective was to validate vitamin D intake from a short vitamin D questionnaire (VDQ) and a longer online food frequency questionnaire (FFQ) against a food record and 25-hydroxyvitamin D (25OHD) as a biomarker of vitamin D status, among pregnant women in Sweden. The number of women included was 1125 with VDQ, FFQ and 25OHD, and of those, 64 also completed the food record. Median vitamin D intakes were 3.9 µg by VDQ ( p D intake from food record and VDQ (rho = 0.51, p D intake. However, only vitamin D intake from the VDQ was significantly associated with vitamin D status as assessed by 25OHD. The validation coefficient for the VDQ was 0.68 and 0.75 for the FFQ. In conclusion, assessing dietary vitamin D intake is challenging, regardless of the dietary assessment method. The VDQ, that includes only four food items, is a valid, simple and useful tool in assessing vitamin D intake of pregnant women in Sweden, while imposing a minimal burden on women and researchers.

  2. In vivo 3D modeling of the femoropopliteal artery in human subjects based on x-ray angiography: Methodology and validation

    International Nuclear Information System (INIS)

    Klein, Andrew J.; Casserly, Ivan P.; Messenger, John C.; Carroll, John D.; Chen, S.-Y. James

    2009-01-01

    Endovascular revascularization of the femoropopliteal (FP) artery has been limited by high rates of restenosis and stent fracture. The unique physical forces that are applied to the FP artery during leg movement have been implicated in these phenomena. The foundation for measuring the effects of physical forces on the FP artery in a clinically relevant environment is based on the ability to develop 3D models of this vessel in different leg positions in vivo in patients with peripheral arterial disease (PAD). By acquiring paired angiographic images of the FP artery, and using angiography-based 3D modeling algorithms previously validated in the coronary arteries, the authors generated 3D models of ten FP arteries in nine patients with PAD with the lower extremity in straight leg (SL) and crossed leg (CL) positions. Due to the length of the FP artery, overlapping paired angiographic images of the entire FP artery were required to image the entire vessel, which necessitated the development of a novel fusion process in order to generate a 3D model of the entire FP artery. The methodology of angiographic acquisition and 3D model generation of the FP artery is described. In a subset of patients, a third angiographic view (i.e., validation view) was acquired in addition to the standard paired views for the purpose of validating the 3D modeling process. The mean root-mean-square (rms) error of the point-to-point distances between the centerline of the main FP artery from the 2D validation view and the centerline from the 3D model placed in the validation view for the SL and CL positions were 0.93±0.19 mm and 1.12±0.25 mm, respectively. Similarly, the mean rms error of the same comparison for the main FP artery and sidebranches for the SL and CL positions were 1.09±0.38 mm and 1.21±0.25 mm, respectively. A separate validation of the novel fusion process was performed by comparing the 3D model of the FP artery derived from fusion of 3D models of adjacent FP segments with

  3. 3D Object Metamorphosis with Pseudo Metameshes

    Directory of Open Access Journals (Sweden)

    MOCANU, B.

    2015-02-01

    Full Text Available In this paper we introduce a novel framework for 3D object metamorphosis, represented by closed triangular meshes. The systems returns a high quality transition sequence, smooth and gradual, that is visual pleasant and consistent to both source and target topologies. The method starts by parameterizing both the source and the target model to a common domain (the unit sphere. Then, the features selected from the two models are aligned by applying the CTPS C2a radial basis functions. We demonstrate how the selected approach can create valid warping by deforming the models embedded into the parametric domain. In the final stage, we propose and validate a novel algorithm to construct a pseudo-supermesh able to approximate both, the source and target 3D objects. By using the pseudo-supermesh we developed a morphing transition consistent with respect to both geometry and topology of the 3D models.

  4. Validating computational predictions of night-time ventilation in Stanford's Y2E2 building

    Science.gov (United States)

    Chen, Chen; Lamberti, Giacomo; Gorle, Catherine

    2017-11-01

    Natural ventilation can significantly reduce building energy consumption, but robust design is a challenging task. We previously presented predictions of natural ventilation performance in Stanford's Y2E2 building using two models with different levels of fidelity, embedded in an uncertainty quantification framework to identify the dominant uncertain parameters and predict quantified confidence intervals. The results showed a slightly high cooling rate for the volume-averaged temperature, and the initial thermal mass temperature and window discharge coefficients were found to have an important influence on the results. To further investigate the potential role of these parameters on the observed discrepancies, the current study is performing additional measurements in the Y2E2 building. Wall temperatures are recorded throughout the nightflush using thermocouples; flow rates through windows are measured using hotwires; and spatial variability in the air temperature is explored. The measured wall temperatures are found the be within the range of our model assumptions, and the measured velocities agree reasonably well with our CFD predications. Considerable local variations in the indoor air temperature have been recorded, largely explaining the discrepancies in our earlier validation study. Future work will therefore focus on a local validation of the CFD results with the measurements. Center for Integrated Facility Engineering (CIFE).

  5. Evaluation and comparison of 3D intervertebral disc localization and segmentation methods for 3D T2 MR data: A grand challenge.

    Science.gov (United States)

    Zheng, Guoyan; Chu, Chengwen; Belavý, Daniel L; Ibragimov, Bulat; Korez, Robert; Vrtovec, Tomaž; Hutt, Hugo; Everson, Richard; Meakin, Judith; Andrade, Isabel Lŏpez; Glocker, Ben; Chen, Hao; Dou, Qi; Heng, Pheng-Ann; Wang, Chunliang; Forsberg, Daniel; Neubert, Aleš; Fripp, Jurgen; Urschler, Martin; Stern, Darko; Wimmer, Maria; Novikov, Alexey A; Cheng, Hui; Armbrecht, Gabriele; Felsenberg, Dieter; Li, Shuo

    2017-01-01

    The evaluation of changes in Intervertebral Discs (IVDs) with 3D Magnetic Resonance (MR) Imaging (MRI) can be of interest for many clinical applications. This paper presents the evaluation of both IVD localization and IVD segmentation methods submitted to the Automatic 3D MRI IVD Localization and Segmentation challenge, held at the 2015 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI2015) with an on-site competition. With the construction of a manually annotated reference data set composed of 25 3D T2-weighted MR images acquired from two different studies and the establishment of a standard validation framework, quantitative evaluation was performed to compare the results of methods submitted to the challenge. Experimental results show that overall the best localization method achieves a mean localization distance of 0.8 mm and the best segmentation method achieves a mean Dice of 91.8%, a mean average absolute distance of 1.1 mm and a mean Hausdorff distance of 4.3 mm, respectively. The strengths and drawbacks of each method are discussed, which provides insights into the performance of different IVD localization and segmentation methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. H?, D? and HD adsorption upon the metal-organic framework [Cu?Zn?(btc)?]? studied by pulsed ENDOR and HYSCORE spectroscopy

    Science.gov (United States)

    Jee, Bettina; Hartmann, Martin; Pöppl, Andreas

    2013-10-01

    The adsorption of hydrogen has become interesting in terms of gas separation as well as safe and reversible storage of hydrogen as an energy carrier. In this regard, metal-organic framework compounds are potential candidates. The metal-organic framework [Cu?Zn?(btc)?]? as a partially Zn-substituted analogue of the well known compound HKUST-1 is well suited for studying adsorption geometries at cupric ions by electron paramagnetic resonance (EPR) methods due to the formation of few mixed Cu/Zn paddle wheel units with isolated S = 1/2 electron spins. The adsorption of hydrogen (H2) as well as the deuterium (D2) and HD molecules were investigated by continuous wave EPR and pulsed ENDOR and HYSCORE spectroscopy. The principal values of the proton and deuterium hyperfine coupling tensors ? and ? were determined by spectral simulations as well as of the deuterium nuclear quadrupole tensor ? for adsorbed HD and D2. The results show a side-on coordination of HD and D2 with identical Cu-H and Cu-D distances rCuX = 2.8 Å with the tensors ? and ? aligned parallel to the C4 symmetry axis of the paddle wheel unit. A thermodynamic non-equilibrium state with J = 1, mJ = ±1 is indicated by the experimental data with ? and ? averaged by rotation around C4.

  7. Monitoring tumor motion by real time 2D/3D registration during radiotherapy.

    Science.gov (United States)

    Gendrin, Christelle; Furtado, Hugo; Weber, Christoph; Bloch, Christoph; Figl, Michael; Pawiro, Supriyanto Ardjo; Bergmann, Helmar; Stock, Markus; Fichtinger, Gabor; Georg, Dietmar; Birkfellner, Wolfgang

    2012-02-01

    In this paper, we investigate the possibility to use X-ray based real time 2D/3D registration for non-invasive tumor motion monitoring during radiotherapy. The 2D/3D registration scheme is implemented using general purpose computation on graphics hardware (GPGPU) programming techniques and several algorithmic refinements in the registration process. Validation is conducted off-line using a phantom and five clinical patient data sets. The registration is performed on a region of interest (ROI) centered around the planned target volume (PTV). The phantom motion is measured with an rms error of 2.56 mm. For the patient data sets, a sinusoidal movement that clearly correlates to the breathing cycle is shown. Videos show a good match between X-ray and digitally reconstructed radiographs (DRR) displacement. Mean registration time is 0.5 s. We have demonstrated that real-time organ motion monitoring using image based markerless registration is feasible. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Comparison and analysis of 1D/2D/3D neutronics modeling for a fusion reactor

    International Nuclear Information System (INIS)

    Li, J.; Zeng, Q.; Chen, M.; Jiang, J.; Wu, Y.

    2007-01-01

    During the course of analyzing the characteristics for fusion reactors, the refined calculations are needed to confirm that the nuclear design requirements are met. Since the long computational time is consumed, the refined three-dimensional (3D) representation has been used primarily for establishing the baseline reference values, analyzing problems which cannot be reduced by symmetry considerations to lower dimensions, or where a high level of accuracy is desired locally. The two-dimensional (2D) or one-dimensional (1D) description leads itself readily to resolve many problems, such as the studies for the material fraction optimization, or for the blanket size optimization. The purpose of this paper is to find out the differences among different geometric descriptions, which can guide the way to approximate and simplify the computational model. The fusion power reactor named FDS-II was designed as an advanced fusion power reactor to demonstrate and validate the commercialization of fusion power by Institute of Plasma Physics, Chinese Academy of Science. In this contribution, the dual-cooled lithium lead (DLL) blanket of FDS-II was used as a reference for neutronics comparisons and analyses. The geometric descriptions include 1D concentric sphere model, 1D, 2D and 3D cylinder models. The home-developed multi-functional neutronics analysis code system VisualBUS, the Monte Carlo transport code MCNP and nuclear data library HENDL have been used for these analyses. The neutron wall loading distribution, tritium breeding ratio (TBR) and nuclear heat were calculated to evaluate the nuclear performance. The 3D calculation has been used as a comparison reference because it has the least errors in the treatment of geometry. It is suggested that the value of TBR calculated by the 1D approach should be greater than 1.3 to satisfy the practical need of tritium self-sufficiency. The distribution of nuclear heat based on the 2D and 3D models were similar since they all consider

  9. Design for validation: An approach to systems validation

    Science.gov (United States)

    Carter, William C.; Dunham, Janet R.; Laprie, Jean-Claude; Williams, Thomas; Howden, William; Smith, Brian; Lewis, Carl M. (Editor)

    1989-01-01

    Every complex system built is validated in some manner. Computer validation begins with review of the system design. As systems became too complicated for one person to review, validation began to rely on the application of adhoc methods by many individuals. As the cost of the changes mounted and the expense of failure increased, more organized procedures became essential. Attempts at devising and carrying out those procedures showed that validation is indeed a difficult technical problem. The successful transformation of the validation process into a systematic series of formally sound, integrated steps is necessary if the liability inherent in the future digita-system-based avionic and space systems is to be minimized. A suggested framework and timetable for the transformtion are presented. Basic working definitions of two pivotal ideas (validation and system life-cyle) are provided and show how the two concepts interact. Many examples are given of past and present validation activities by NASA and others. A conceptual framework is presented for the validation process. Finally, important areas are listed for ongoing development of the validation process at NASA Langley Research Center.

  10. A 3d-4f complex constructed by the assembly of a cationic template, [Cu(en){sub 2}]{sup 2+}, and a 3D anionic coordination polymer, [Sm{sub 2}(C{sub 2}O{sub 4}){sub 3}(C{sub 5}O{sub 5})(H{sub 2}O){sub 2}]{sup 2-}

    Energy Technology Data Exchange (ETDEWEB)

    Ke, Szu-Yu; Yeh, Chang-Tsung; Wang, Chih-Chieh [Department of Chemistry, Soochow University, Taipei, Taiwan (China); Lee, Gene-Hsiang [Instrumentation Center, National Taiwan University, Taipei, Taiwan (China); Sheu, Hwo-Shuenn [National Synchrotron Radiation Research Center, Hsinchu, Taiwan (China)

    2017-05-18

    A three-dimensional (3D) 3d-4f complex, [Cu(en){sub 2}][Sm{sub 2}(C{sub 5}O{sub 5})(C{sub 2}O{sub 4}){sub 3}(H{sub 2}O){sub 2}].8H{sub 2}O (1) (en = ethylenediamine, C{sub 5}O{sub 5}{sup 2-} = dianion of 4,5-dihydroxycyclopent-4-ene-1,2,3-trione), were prepared via the in-situ ring-opening oxidation reaction of croconate in the presence of the template-directed complex, [Cu(en){sub 2}]{sup 2+} cation. The structural characterization determined by X-ray diffraction determination reveals that the 3D anionic coordination polymer of [Sm{sub 2}(C{sub 2}O{sub 4}){sub 3}(C{sub 5}O{sub 5})(H{sub 2}O){sub 2}]{sup 2-} in 1 can be describe in terms of in-plane 2D honeycomb-like [Sm{sub 2}(C{sub 2}O{sub 4}){sub 3}] layered frameworks bridged by oxalate with bis-chelating mode, being mutually interlinked via the bridge of μ{sub 1,2,3,4}-croconate ligands with bis-chelating coordination mode to complete the 3D open framework, which gives rise to 1D channels with pore size of 14.023 x 11.893 Aa (longest atom-atom contact distances) along the b axis. The structure-directing complex, [Cu(en){sub 2}]{sup 2+}, and solvated water molecules are resided into these honeycomb-type hexagonal channels. The thermal stability of 1 was further studied by TGA and in-situ powder X-ray diffraction measurement. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Solvothermal synthesis of a new 3-D mixed-metal sulfide framework, (H{sub 1.33}tren)[In{sub 2.67}Sb{sub 1.33}S{sub 8}]·tren

    Energy Technology Data Exchange (ETDEWEB)

    Lampkin, John D., E-mail: j.lampkin@pgr.rdg.ac.uk; Powell, Anthony V., E-mail: a.v.powell@rdg.ac.uk; Chippindale, Ann M., E-mail: a.m.chippindale@rdg.ac.uk

    2016-11-15

    A new indium(III) antimony(V) sulfide, (H{sub 1.33}tren)[In{sub 2.67}Sb{sub 1.33}S{sub 8}]·tren, has been prepared solvothermally at 433 K. The compound crystallises in the tetragonal space group I-42d (lattice parameters, a=12.6248(5) and c=19.4387(18) Å at 150 K) and contains adamantane-like T2 supertetrahedral units comprised of corner-sharing InS{sub 4}{sup 5−} and SbS{sub 4}{sup 3−} tetrahedra. The adamantane-like units are then linked through sulfur vertices to generate an open, 3-D framework structure containing large pores in which neutral, protonated tren (tris(2-aminoethylene)amine) molecules reside. The presence of the organic components was confirmed by solid-state {sup 13}C NMR (10 kHz), combustion and thermogravimetric analysis. The band gap, obtained from UV–vis diffuse reflectance measurements, is 2.7(2) eV. Stirring with either water or alkali-metal salt solution leads to removal of the neutral tren molecules and an ~9% reduction in unit-cell volume on formation of (H{sub 1.33}tren)[In{sub 2.67}Sb{sub 1.33}S{sub 8}]·(H{sub 2}O){sub 4}. - Graphical abstract: Linking of In(III)-Sb(V)-S adamantane units to form a 3-D open framework. - Highlights: • Preparation and structural characterisation of a new mixed-metal thiometallate. • The first mixed In(III)/Sb(V) supertetrahedron. • Optical band gap of 2.7(2) eV. • Soaking in aqueous alkali-metal solutions leads to removal of ca. 50% of the organic content.

  12. Quantifying frontal plane knee motion during single limb squats: reliability and validity of 2-dimensional measures.

    Science.gov (United States)

    Gwynne, Craig R; Curran, Sarah A

    2014-12-01

    Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.

  13. Validation of SCIAMACHY HDO/H2O measurements using the TCCON and NDACC-MUSICA networks

    Science.gov (United States)

    Scheepmaker, R. A.; Frankenberg, C.; Deutscher, N. M.; Schneider, M.; Barthlott, S.; Blumenstock, T.; Garcia, O. E.; Hase, F.; Jones, N.; Mahieu, E.; Notholt, J.; Velazco, V.; Landgraf, J.; Aben, I.

    2015-04-01

    Measurements of the atmospheric HDO/H2O ratio help us to better understand the hydrological cycle and improve models to correctly simulate tropospheric humidity and therefore climate change. We present an updated version of the column-averaged HDO/H2O ratio data set from the SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY). The data set is extended with 2 additional years, now covering 2003-2007, and is validated against co-located ground-based total column δD measurements from Fourier transform spectrometers (FTS) of the Total Carbon Column Observing Network (TCCON) and the Network for the Detection of Atmospheric Composition Change (NDACC, produced within the framework of the MUSICA project). Even though the time overlap among the available data is not yet ideal, we determined a mean negative bias in SCIAMACHY δD of -35 ± 30‰ compared to TCCON and -69 ± 15‰ compared to MUSICA (the uncertainty indicating the station-to-station standard deviation). The bias shows a latitudinal dependency, being largest (∼ -60 to -80‰) at the highest latitudes and smallest (∼ -20 to -30‰) at the lowest latitudes. We have tested the impact of an offset correction to the SCIAMACHY HDO and H2O columns. This correction leads to a humidity- and latitude-dependent shift in δD and an improvement of the bias by 27‰, although it does not lead to an improved correlation with the FTS measurements nor to a strong reduction of the latitudinal dependency of the bias. The correction might be an improvement for dry, high-altitude areas, such as the Tibetan Plateau and the Andes region. For these areas, however, validation is currently impossible due to a lack of ground stations. The mean standard deviation of single-sounding SCIAMACHY-FTS differences is ∼ 115‰, which is reduced by a factor ∼ 2 when we consider monthly means. When we relax the strict matching of individual measurements and focus on the mean seasonalities using all available

  14. Analysis results from the Los Alamos 2D/3D program

    International Nuclear Information System (INIS)

    Boyack, B.E.; Cappiello, M.W.; Stumpf, H.; Shire, P.; Gilbert, J.; Hedstrom, J.

    1986-01-01

    Los Alamos National Laboratory is a participant in the 2D/3D program. Activities conducted at Los Alamos National Laboratory in support of 2D/3D program goals include analysis support of facility design, construction, and operation; provision of boundary and initial conditions for test facility operations based on analysis of pressurized water reactors; performance of pretest and posttest predictions and analyses; and use of experimental results to validate and assess the single- and multidimensional nonequilibrium features in the Transient Reactor Analysis Code (TRAC). During Fiscal Year 1986, Los Alamos conducted analytical assessment activities using data from the Cylindrical Core Test Facility and the Slab Core Test Facility. Los Alamos also continued to provide support analysis for the planning of Upper Plenum Test Facility experiments. Finally, Los Alamos either completed or is currently working on three areas of TRAC modeling improvement. In this paper, Los Alamos activities during Fiscal Year 1986 are summarized; several significant accomplishments are described in more detail to illustrate the work activities at Los Alamos

  15. Translation of the 5D Itching Scale from English to Malay, and Its Validation among Patients with Chronic Kidney Disease in Malaysia

    Directory of Open Access Journals (Sweden)

    Inayat Ur Rehman

    2017-11-01

    Full Text Available IntroductionSeveral tools have been developed to assess the severity of pruritus. In Malaysia, no tool has been validated to assess pruritus in patients with chronic kidney disease (CKD. Therefore, the aim of our study was to validate the Malay 5D itching scale (M5D-IS among patients with CKD in Malaysia.MethodThe English version of the 5D-IS was translated into Malay according to International Guidelines. Face and content validity was determined by an expert panel and pilot tested in patients with end-stage renal disease (ESRD. The M5D-IS was then validated in a tertiary hospital in Malaysia from May to June 2016. We recruited patients with (i.e., patients with ESRD and without pruritus (i.e., patients with stage 1–3 CKD (to determine if the M5D-IS could discriminate between the two groups, and administered the M5D-IS at baseline and 2 weeks later. Exploratory factor analysis was used to examine the construct validity. Internal consistency was assessed using Cronbach’s alpha and intraclass correlation coefficient was calculated to assess the reliability of the instrument.ResultsA total of 70 participants were recruited (response rate = 100%. The majority were males (51.4% and Malay (67.1%. Exploratory factor analysis revealed that the 5D-IS had 2-factor loadings: “daily routine activity” and “pattern of itching,” which explained 77.7% of the variance. The overall score of the M5D-IS, as well as for each domain, was significantly worse in participants with pruritus (9.83 ± 0.35, compared to those without pruritus (5.51 ± 0.93, p < 0.001. The overall Cronbach’s alpha for the M5D-IS was (0.861, indicating adequate internal consistency. At test–retest, the intraclass correlation coefficient was significantly correlated.ConclusionThe M5D-IS was found to be a valid and reliable instrument to assess pruritus among patients with CKD in Malaysia.

  16. Photoluminescence properties of lanthanide-organic frameworks (LnOFs) with thiophene-2,5-dicarboxylate and acetate

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jing; Wei, Qing; Xie, Gang; Chen, Sanping [Key Lab. of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry and Materials Science, Northwest Univ., Xi' an, Shaanxi (China); Zhang, Sheng [Key Lab. of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry and Materials Science, Northwest Univ., Xi' an, Shaanxi (China); College of Chemistry and Chemical Engineering, Baoji Univ. of Arts and Science, Baoji, Shaanxi (China)

    2017-07-17

    S-heterocyclic dicarboxylic acid, thiophene-2,5-dicarboxylic acid (H{sub 2}TDC), was employed to construct a series of lanthanide-organic frameworks (LnOFs) with coligand acetate, formulated as [Ln(TDC)(OAc)(H{sub 2}O)]{sub n} [Ln = Eu (1), Tb (2), Gd (3), Dy (4), Sm (5)] under hydrothermal conditions. Structure analysis reveals that 1-5 have dinuclear 3D metal organic frameworks (MOFs), in which TDC{sup 2-} and OAc{sup -} display (κ{sup 1}-κ{sup 1})-(κ{sup 1}-κ{sup 1})-μ{sub 4} and (κ{sup 2}-κ{sup 1})-μ{sub 2} coordination fashions, respectively. The dehydrated products of all compounds show high thermal stability above 410 C. As for 1, 2, 4, and 5, the photoluminescence analyses exhibit characteristic luminescence emission bands of the corresponding lanthanide ions in the visible region. In particular, compound 2 displays bright green luminescence in the solid state with {sup 5}D{sub 4} lifetime of 0.510 ms and relative high overall quantum yield of 16 %, based on an ideal energy gap between the lowest triplet state energy level of H{sub 2}TDC ligand and the {sup 5}D{sub 4} state energy level of Tb{sup 3+}. The energy transfer mechanisms in compounds 1 and 2 were also discussed. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Using a 2D detector array for meaningful and efficient linear accelerator beam property validations.

    Science.gov (United States)

    Ritter, Timothy A; Gallagher, Ian; Roberson, Peter L

    2014-11-08

    Following linear accelerator commissioning, the qualified medical physicist is responsible for monitoring the machine's ongoing performance, detecting and investigating any changes in beam properties, and assessing the impact of unscheduled repairs. In support of these responsibilities, the authors developed a method of using a 2D ionization chamber array to efficiently test and validate important linear accelerator photon beam properties. A team of three physicists identified critical properties of the accelerator and developed constancy tests that were sensitive to each of the properties. The result was a 14-field test plan. The test plan includes large and small fields at varying depths, a reduced SSD field at shallow depth for sensitivity to extra focal photon and electron components, and analysis of flatness, symmetry, dose, dose profiles, and dose ratios. Constancy tests were repeated five times over a period of six weeks and used to set upper and lower investigation levels at ± 3 SDs. Deliberate variations in output, penumbra, and energy were tested to determine the suitability of the proposed method. Measurements were also performed on a similar, but distinct, machine to assess test sensitivity. The results demonstrated upper and lower investigation levels significantly smaller than the comparable TG-142 annual recommendations, with the exception of the surrogate used for output calibration, which still fell within the TG-142 monthly recommendation. Subtle changes in output, beam energy, and penumbra were swiftly identified for further investigation. The test set identified the distinct nature of the second accelerator. The beam properties of two photon energies can be validated in approximately 1.5 hrs using this method. The test suite can be used to evaluate the impact of minor repairs, detect changes in machine performance over time, and supplement other machine quality assurance testing.

  18. CYP2D7 sequence variation interferes with TaqMan CYP2D6*15 and *35 genotyping

    Directory of Open Access Journals (Sweden)

    Amanda K Riffel

    2016-01-01

    Full Text Available TaqMan™ genotyping assays are widely used to genotype CYP2D6, which encodes a major drug metabolizing enzyme. Assay design for CYP2D6 can be challenging owing to the presence of two pseudogenes, CYP2D7 and CYP2D8, structural and copy number variation and numerous single nucleotide polymorphisms (SNPs some of which reflect the wild-type sequence of the CYP2D7 pseudogene. The aim of this study was to identify the mechanism causing false positive CYP2D6*15 calls and remediate those by redesigning and validating alternative TaqMan genotype assays. Among 13,866 DNA samples genotyped by the CompanionDx® lab on the OpenArray platform, 70 samples were identified as heterozygotes for 137Tins, the key SNP of CYP2D6*15. However, only 15 samples were confirmed when tested with the Luminex xTAG CYP2D6 Kit and sequencing of CYP2D6-specific long range (XL-PCR products. Genotype and gene resequencing of CYP2D6 and CYP2D7-specific XL-PCR products revealed a CC>GT dinucleotide SNP in exon 1 of CYP2D7 that reverts the sequence to CYP2D6 and allows a TaqMan assay PCR primer to bind. Because CYP2D7 also carries a Tins, a false-positive mutation signal is generated. This CYP2D7 SNP was also responsible for generating false-positive signals for rs769258 (CYP2D6*35 which is also located in exon 1. Although alternative CYP2D6*15 and *35 assays resolved the issue, we discovered a novel CYP2D6*15 subvariant in one sample that carries additional SNPs preventing detection with the alternate assay. The frequency of CYP2D6*15 was 0.1% in this ethnically diverse U.S. population sample. In addition, we also discovered linkage between the CYP2D7 CC>GT dinucleotide SNP and the 77G>A (rs28371696 SNP of CYP2D6*43. The frequency of this tentatively functional allele was 0.2%. Taken together, these findings emphasize that regardless of how careful genotyping assays are designed and evaluated before being commercially marketed, rare or unknown SNPs underneath primer and/or probe

  19. Recent Developments in 2D Nanomaterials for Chemiresistive-Type Gas Sensors

    Science.gov (United States)

    Choi, Seon-Jin; Kim, Il-Doo

    2018-03-01

    Two-dimensional (2D) nanostructures are gaining tremendous interests due to the fascinating physical, chemical, electrical, and optical properties. Recent advances in 2D nanomaterials synthesis have contributed to optimization of various parameters such as physical dimension and chemical structure for specific applications. In particular, development of high performance gas sensors is gaining vast importance for real-time and on-site environmental monitoring by detection of hazardous chemical species. In this review, we comprehensively report recent achievements of 2D nanostructured materials for chemiresistive-type gas sensors. Firstly, the basic sensing mechanism is described based on charge transfer behavior between gas species and 2D nanomaterials. Secondly, diverse synthesis strategies and characteristic gas sensing properties of 2D nanostructures such as graphene, metal oxides, transition metal dichalcogenides (TMDs), metal organic frameworks (MOFs), phosphorus, and MXenes are presented. In addition, recent trends in synthesis of 2D heterostructures by integrating two different types of 2D nanomaterials and their gas sensing properties are discussed. Finally, this review provides perspectives and future research directions for gas sensor technology using various 2D nanomaterials.

  20. Recent Developments in 2D Nanomaterials for Chemiresistive-Type Gas Sensors

    Science.gov (United States)

    Choi, Seon-Jin; Kim, Il-Doo

    2018-05-01

    Two-dimensional (2D) nanostructures are gaining tremendous interests due to the fascinating physical, chemical, electrical, and optical properties. Recent advances in 2D nanomaterials synthesis have contributed to optimization of various parameters such as physical dimension and chemical structure for specific applications. In particular, development of high performance gas sensors is gaining vast importance for real-time and on-site environmental monitoring by detection of hazardous chemical species. In this review, we comprehensively report recent achievements of 2D nanostructured materials for chemiresistive-type gas sensors. Firstly, the basic sensing mechanism is described based on charge transfer behavior between gas species and 2D nanomaterials. Secondly, diverse synthesis strategies and characteristic gas sensing properties of 2D nanostructures such as graphene, metal oxides, transition metal dichalcogenides (TMDs), metal organic frameworks (MOFs), phosphorus, and MXenes are presented. In addition, recent trends in synthesis of 2D heterostructures by integrating two different types of 2D nanomaterials and their gas sensing properties are discussed. Finally, this review provides perspectives and future research directions for gas sensor technology using various 2D nanomaterials.

  1. Computer assisted determination of acetabular cup orientation using 2D-3D image registration

    International Nuclear Information System (INIS)

    Zheng, Guoyan; Zhang, Xuan

    2010-01-01

    2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations. A new formulation for determination of post-operative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips. Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 ± 0.7 (range from 0.1 to 2.0 ) for inclination and 1.7 ± 1.2 (range from 0.0 to 3.9 ) for anteversion, taking the measurements from post-operative CT images as ground truths. Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of post-operative cup orientation and measurement of pelvic tilt and rotation. (orig.)

  2. Reconstruction of incomplete cell paths through a 3D-2D level set segmentation

    Science.gov (United States)

    Hariri, Maia; Wan, Justin W. L.

    2012-02-01

    Segmentation of fluorescent cell images has been a popular technique for tracking live cells. One challenge of segmenting cells from fluorescence microscopy is that cells in fluorescent images frequently disappear. When the images are stacked together to form a 3D image volume, the disappearance of the cells leads to broken cell paths. In this paper, we present a segmentation method that can reconstruct incomplete cell paths. The key idea of this model is to perform 2D segmentation in a 3D framework. The 2D segmentation captures the cells that appear in the image slices while the 3D segmentation connects the broken cell paths. The formulation is similar to the Chan-Vese level set segmentation which detects edges by comparing the intensity value at each voxel with the mean intensity values inside and outside of the level set surface. Our model, however, performs the comparison on each 2D slice with the means calculated by the 2D projected contour. The resulting effect is to segment the cells on each image slice. Unlike segmentation on each image frame individually, these 2D contours together form the 3D level set function. By enforcing minimum mean curvature on the level set surface, our segmentation model is able to extend the cell contours right before (and after) the cell disappears (and reappears) into the gaps, eventually connecting the broken paths. We will present segmentation results of C2C12 cells in fluorescent images to illustrate the effectiveness of our model qualitatively and quantitatively by different numerical examples.

  3. 2D geometric morphometric analysis casts doubt on the validity of large tanged points as cultural markers in the European Final Palaeolithic

    DEFF Research Database (Denmark)

    Serwatka, Kamil; Riede, Felix

    2016-01-01

    directeurs, especially in northern Europe. The vast majority of these finds are from the surface or derive from less-than-secure contexts. Several recent papers have cast doubt on the validity of this artefact class as a taxonomically sensitive marker. Here, we further investigate this issue using 2D...... arch-backed points. Their presence in later assemblages and technocomplexes such as the Brommean cannot therefore be considered as a derived or diagnostic feature. We suggest that this artefact class should rather be linked to weapon systems function (dart-points) different from the coeval arch...

  4. Validating the Type D personality construct in Chinese patients with coronary heart disease

    DEFF Research Database (Denmark)

    Yu, Doris S F; Thompson, David R; Yu, Cheuk Man

    2010-01-01

    Type D personality predicts poor prognosis in coronary heart disease (CHD) but little is known about Type D in non-Western cultures. We examined the (a) validity of the Type D construct and its assessment with the DS14 scale in the Chinese culture, (b) prevalence of Type D, and (c) gender vs. Typ...

  5. Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction.

    Science.gov (United States)

    Song, Jiayu; Liu, Yanhui; Gewalt, Sally L; Cofer, Gary; Johnson, G Allan; Liu, Qing Huo

    2009-04-01

    Radially encoded MRI has gained increasing attention due to its motion insensitivity and reduced artifacts. However, because its samples are collected nonuniformly in the k-space, multidimensional (especially 3-D) radially sampled MRI image reconstruction is challenging. The objective of this paper is to develop a reconstruction technique in high dimensions with on-the-fly kernel calculation. It implements general multidimensional nonuniform fast Fourier transform (NUFFT) algorithms and incorporates them into a k-space image reconstruction framework. The method is then applied to reconstruct from the radially encoded k-space data, although the method is applicable to any non-Cartesian patterns. Performance comparisons are made against the conventional Kaiser-Bessel (KB) gridding method for 2-D and 3-D radially encoded computer-simulated phantoms and physically scanned phantoms. The results show that the NUFFT reconstruction method has better accuracy-efficiency tradeoff than the KB gridding method when the kernel weights are calculated on the fly. It is found that for a particular conventional kernel function, using its corresponding deapodization function as a scaling factor in the NUFFT framework has the potential to improve accuracy. In particular, when a cosine scaling factor is used, the NUFFT method is faster than KB gridding method since a closed-form solution is available and is less computationally expensive than the KB kernel (KB griding requires computation of Bessel functions). The NUFFT method has been successfully applied to 2-D and 3-D in vivo studies on small animals.

  6. German Translation and Validation of the Cognitive Style Questionnaire Short Form (CSQ-SF-D.

    Directory of Open Access Journals (Sweden)

    Quentin J M Huys

    Full Text Available The Cognitive Style Questionnaire is a valuable tool for the assessment of hopeless cognitive styles in depression research, with predictive power in longitudinal studies. However, it is very burdensome to administer. Even the short form is still long, and neither this nor the original version exist in validated German translations.The questionnaire was translated from English to German, back-translated and commented on by clinicians. The reliability, factor structure and external validity of an online form of the questionnaire were examined on 214 participants. External validity was measured on a subset of 90 subjects.The resulting CSQ-SF-D had good to excellent reliability, both across items and subscales, and similar external validity to the original English version. The internality subscale appeared less robust than other subscales. A detailed analysis of individual item performance suggests that stable results could be achieved with a very short form (CSQ-VSF-D including only 27 of the 72 items.The CSQ-SF-D is a validated and freely distributed translation of the CSQ-SF into German. This should make efficient assessment of cognitive style in German samples more accessible to researchers.

  7. Facade Reconstruction with Generalized 2.5d Grids

    Directory of Open Access Journals (Sweden)

    J. Demantke

    2013-10-01

    Full Text Available Reconstructing fine facade geometry from MMS lidar data remains a challenge: In addition to being inherently sparse, the point cloud provided by a single street point of view is necessarily incomplete. We propose a simple framework to estimate the facade surface with a deformable 2.5d grid. Computations are performed in a "sensor-oriented" coordinate system that maximizes consistency with the data. the algorithm allows to retrieve the facade geometry without priori knowledge. It can thus be automatically applied to a large amount of data in spite of the variability of encountered architectural forms. The 2.5d image structure of the output makes it compatible with storage and real-time constraints of immersive navigation.

  8. Character relations and replication identities in 2d Conformal Field Theory

    Energy Technology Data Exchange (ETDEWEB)

    Bantay, P. [Institute for Theoretical Physics, Eötvös Loránd University,H-1117 Budapest, Pázmány P.s. 1/A (Hungary)

    2016-10-05

    We study replication identities satisfied by conformal characters of a 2D CFT, providing a natural framework for a physics interpretation of the famous Hauptmodul property of Monstrous Moonshine, and illustrate the underlying ideas in simple cases.

  9. Validation of an e-Learning 3.0 Critical Success Factors Framework: A Qualitative Research

    Directory of Open Access Journals (Sweden)

    Paula Miranda

    2017-09-01

    Full Text Available Aim/Purpose: As e-Learning 3.0 evolves from a theoretical construct into an actual solution for online learning, it becomes crucial to accompany this progress by scrutinising the elements that are at the origin of its success. Background: This paper outlines a framework of e-Learning 3.0’s critical success factors and its empirical validation. Methodology: The framework is the result of an extensive literature review and its empirical substantiation derives from semi-structured interviews with e-Learning experts. Contribution: The viewpoints of the experts enable the confirmation and the refinement of the original framework and serve as a foundation for the prospective implementation of e-Learning 3.0. Findings: The analysis of the interviews demonstrates that e-Learning 3.0 remains in its early stages with a reticent dissemination. Nonetheless, the interviewees invoked factors related to technology, content and stakeholders as being critical for the success of this new phase of e-Learning. Recommendations for Practitioners: Practitioners can use the framework as a guide for promoting and implementing effective e-Learning 3.0 initiatives. Recommendation for Researchers: As a new phenomenon with uncharted potential, e-Learning 3.0 should be placed at the centre of educational research. Impact on Society: The understanding of what drives the success of e-Learning 3.0 is fundamental for its implementation and for the progress of online education in this new stage of its evolution. Future Research: Future research ventures can include the design of quantitative and self-administered data collection instruments that can provide further insight into the elements of the framework.

  10. [GRADE Evidence to Decision (EtD) frameworks: a systematic and transparent approach to making well informed healthcare choices. 1: Introduction].

    Science.gov (United States)

    Alonso-Coello, Pablo; Schünemann, Holger J; Moberg, Jenny; Brignardello-Petersen, Romina; Akl, Elie A; Davoli, Marina; Treweek, Shaun; Mustafa, Reem A; Rada, Gabriel; Rosenbaum, Sarah; Morelli, Angela; Guyatt, Gordon H; Oxman, Andrew D

    Clinicians, guideline developers, and policymakers sometimes neglect important criteria, give undue weight to criteria, and do not use the best available evidence to inform their judgments. Explicit and transparent systems for decision making can help to ensure that all important criteria are considered and that decisions are informed by the best available research evidence. The GRADE Working Group has developed Evidence to Decision (EtD) frameworks for the different type of recommendations or decisions. The purpose of EtD frameworks is to help people use evidence in a structured and transparent way to inform decisions in the context of clinical recommendations, coverage decisions, and health system or public health recommendations and decisions. EtD frameworks have a common structure that includes formulation of the question, an assessment of the evidence, and drawing conclusions, though there are some differences between frameworks for each type of decision. EtD frameworks inform users about the judgments that were made and the evidence supporting those judgments by making the basis for decisions transparent to target audiences. EtD frameworks also facilitate dissemination of recommendations and enable decision makers in other jurisdictions to adopt recommendations or decisions, or adapt them to their context. This article is a translation of the original article published in British Medical Journal. The EtD frameworks are currently used in the Clinical Practice Guideline Programme of the Spanish National Health System, co-ordinated by GuíaSalud. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Measuring the Value of New Drugs: Validity and Reliability of 4 Value Assessment Frameworks in the Oncology Setting.

    Science.gov (United States)

    Bentley, Tanya G K; Cohen, Joshua T; Elkin, Elena B; Huynh, Julie; Mukherjea, Arnab; Neville, Thanh H; Mei, Matthew; Copher, Ronda; Knoth, Russell; Popescu, Ioana; Lee, Jackie; Zambrano, Jenelle M; Broder, Michael S

    2017-06-01

    Several organizations have developed frameworks to systematically assess the value of new drugs. To evaluate the convergent validity and interrater reliability of 4 value frameworks to understand the extent to which these tools can facilitate value-based treatment decisions in oncology. Eight panelists used the American Society of Clinical Oncology (ASCO), European Society for Medical Oncology (ESMO), Institute for Clinical and Economic Review (ICER), and National Comprehensive Cancer Network (NCCN) frameworks to conduct value assessments of 15 drugs for advanced lung and breast cancers and castration-refractory prostate cancer. Panelists received instructions and published clinical data required to complete the assessments, assigning each drug a numeric or letter score. Kendall's Coefficient of Concordance for Ranks (Kendall's W) was used to measure convergent validity by cancer type among the 4 frameworks. Intraclass correlation coefficients (ICCs) were used to measure interrater reliability for each framework across cancers. Panelists were surveyed on their experiences. Kendall's W across all 4 frameworks for breast, lung, and prostate cancer drugs was 0.560 (P= 0.010), 0.562 (P = 0.010), and 0.920 (P fair to excellent, increasing with clinical benefit subdomain concordance and simplicity of drug trial data. Interrater reliability, highest for ASCO and ESMO, improved with clarity of instructions and specificity of score definitions. Continued use, analyses, and refinements of these frameworks will bring us closer to the ultimate goal of using value-based treatment decisions to improve patient care and outcomes. This work was funded by Eisai Inc. Copher and Knoth are employees of Eisai Inc. Bentley, Lee, Zambrano, and Broder are employees of Partnership for Health Analytic Research, a health services research company paid by Eisai Inc. to conduct this research. For this study, Cohen, Huynh, and Neville report fees from Partnership for Health Analytic Research

  12. A Computational Framework for Quantifying and Optimizing the Performance of Observational Networks in 4D-Var Data Assimilation

    Science.gov (United States)

    Cioaca, Alexandru

    A deep scientific understanding of complex physical systems, such as the atmosphere, can be achieved neither by direct measurements nor by numerical simulations alone. Data assimila- tion is a rigorous procedure to fuse information from a priori knowledge of the system state, the physical laws governing the evolution of the system, and real measurements, all with associated error statistics. Data assimilation produces best (a posteriori) estimates of model states and parameter values, and results in considerably improved computer simulations. The acquisition and use of observations in data assimilation raises several important scientific questions related to optimal sensor network design, quantification of data impact, pruning redundant data, and identifying the most beneficial additional observations. These questions originate in operational data assimilation practice, and have started to attract considerable interest in the recent past. This dissertation advances the state of knowledge in four dimensional variational (4D-Var) data assimilation by developing, implementing, and validating a novel computational framework for estimating observation impact and for optimizing sensor networks. The framework builds on the powerful methodologies of second-order adjoint modeling and the 4D-Var sensitivity equations. Efficient computational approaches for quantifying the observation impact include matrix free linear algebra algorithms and low-rank approximations of the sensitivities to observations. The sensor network configuration problem is formulated as a meta-optimization problem. Best values for parameters such as sensor location are obtained by optimizing a performance criterion, subject to the constraint posed by the 4D-Var optimization. Tractable computational solutions to this "optimization-constrained" optimization problem are provided. The results of this work can be directly applied to the deployment of intelligent sensors and adaptive observations, as well as

  13. Two-phase 1D+1D model of a DMFC: development and validation on extensive operating conditions range

    Energy Technology Data Exchange (ETDEWEB)

    Casalegno, A.; Marchesi, R.; Parenti, D. [Dipartimento di Energetica, Politecnico di Milano (Italy)

    2008-02-15

    A two-phase 1D+1D model of a direct methanol fuel cell (DMFC) is developed, considering overall mass balance, methanol transport in gas phase through anode diffusion layer, methanol and water crossover. The model is quantitatively validated on an extensive range of operating conditions, 24 polarisation curves. The model accurately reproduces DMFC performance in the validation range and, outside this, it is able to predict values under feasible operating conditions. Finally, the estimations of methanol crossover flux are qualitatively and quantitatively similar to experimental measures and the main local quantities' trends are coherent with results obtained with more complex models. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  14. dCache: implementing a high-end NFSv4.1 service using a Java NIO framework

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    dCache is a high performance scalable storage system widely used by HEP community. In addition to set of home grown protocols we also provide industry standard access mechanisms like WebDAV and NFSv4.1. This support places dCache as a direct competitor to commercial solutions. Nevertheless conforming to a protocol is not enough; our implementations must perform comparably or even better than commercial systems. To achieve this, dCache uses two high-end IO frameworks from well know application servers: GlassFish and JBoss. This presentation describes how we implemented an rfc1831 and rfc2203 compliant ONC RPC (Sun RPC) service based on the Grizzly NIO framework, part of the GlassFish application server. This ONC RPC service is the key component of dCache’s NFSv4.1 implementation, but is independent of dCache and available for other projects. We will also show some details of dCache NFS v4.1 implementations, describe some of the Java NIO techniques used and, finally, present details of our performance e...

  15. Validation of a food frequency questionnaire to determine vitamin D intakes using the method of triads.

    Science.gov (United States)

    Weir, R R; Carson, E L; Mulhern, M S; Laird, E; Healy, M; Pourshahidi, L K

    2016-04-01

    Dietary sources of vitamin D (both natural and fortified) are increasingly contributing to consumers' vitamin D intake and status. Therefore, the present study aimed to validate a vitamin D food frequency questionnaire (FFQ) for the assessment of habitual vitamin D intake. A total of 49 apparently healthy consenting adults (aged 18-64 years) from the local community were sampled at the end of winter. Dietary intakes were recorded using a 4-day weighed food record (4d-WFR) and a 17-item FFQ based on foods known to contribute to dietary vitamin D intake. Fasting vitamin D status was quantified by serum 25-hydroxyvitamin D [25(OH)D] using liquid chromatography tandem mass spectrometry. The method of triads was applied using these three measurements to determine the overall validity of the FFQ. Vitamin D intakes from 4d-WFR ranged between 0.42 and 31.65 μg day(-1), whereas intakes determined from the FFQ ranged from 1.03 to 36.08 μg day(-1). Serum 25(OH)D concentrations ranged between 12.89 and 279.00 nmol L(-1). The mean (SD) difference between the FFQ and 4d-WFR was +1.62 ( 3.86). There were strong correlations between the vitamin D intake estimated by the FFQ and that from the 4d-WFR (r = 0.562) and also with serum 25(OH)D concentrations (r = 0.567). Vitamin D intake estimated from the 4d-WFR was also strongly correlated with serum 25(OH)D concentrations (r = 0.411). The overall validity coefficient calculated using the method of triads was high (0.881). The vitamin D FFQ has been validated for use in future studies aiming to assess habitual vitamin D intake. © 2015 The British Dietetic Association Ltd.

  16. Exploring 3D non-interpenetrated metal-organic framework with malonate-bridged Co(II) coordination polymer: structural elucidation and theoretical study

    Science.gov (United States)

    Hossain, Anowar; Mandal, Tripti; Mitra, Monojit; Manna, Prankrishna; Bauzá, Antonio; Frontera, Antonio; Seth, Saikat Kumar; Mukhopadhyay, Subrata

    2017-12-01

    A Co(II)-based coordination polymer with tetranuclear cobalt(II)-malonate cluster has been easily generated by aqueous medium self-assembly from Cobalt(II) chloride hexahydrate and malonic acid. The structure exhibits a non-interpenetrating, highly undulating two-dimensional (2D) bi-layer network with (4,4) topology. The crystal structure is composed of infinite interdigitated 2D metal-organic bi-layers which extended to an intricate 3D framework through the interbilayer hydrogen bonds. We have studied energetically by means of Density Functional Theory (DFT) calculations the H-bonding interactions that connect the 2D metal-organic bi-layers. The finite theoretical models have been used to compute conventional O‒H•••O and unconventional C‒H•••O interactions which plays a key role to build 3D architecture.

  17. MSX-3D: a tool to validate 3D protein models using mass spectrometry.

    Science.gov (United States)

    Heymann, Michaël; Paramelle, David; Subra, Gilles; Forest, Eric; Martinez, Jean; Geourjon, Christophe; Deléage, Gilbert

    2008-12-01

    The technique of chemical cross-linking followed by mass spectrometry has proven to bring valuable information about the protein structure and interactions between proteic subunits. It is an effective and efficient way to experimentally investigate some aspects of a protein structure when NMR and X-ray crystallography data are lacking. We introduce MSX-3D, a tool specifically geared to validate protein models using mass spectrometry. In addition to classical peptides identifications, it allows an interactive 3D visualization of the distance constraints derived from a cross-linking experiment. Freely available at http://proteomics-pbil.ibcp.fr

  18. Model performance evaluation (validation and calibration) in model-based studies of therapeutic interventions for cardiovascular diseases : a review and suggested reporting framework.

    Science.gov (United States)

    Haji Ali Afzali, Hossein; Gray, Jodi; Karnon, Jonathan

    2013-04-01

    Decision analytic models play an increasingly important role in the economic evaluation of health technologies. Given uncertainties around the assumptions used to develop such models, several guidelines have been published to identify and assess 'best practice' in the model development process, including general modelling approach (e.g., time horizon), model structure, input data and model performance evaluation. This paper focuses on model performance evaluation. In the absence of a sufficient level of detail around model performance evaluation, concerns regarding the accuracy of model outputs, and hence the credibility of such models, are frequently raised. Following presentation of its components, a review of the application and reporting of model performance evaluation is presented. Taking cardiovascular disease as an illustrative example, the review investigates the use of face validity, internal validity, external validity, and cross model validity. As a part of the performance evaluation process, model calibration is also discussed and its use in applied studies investigated. The review found that the application and reporting of model performance evaluation across 81 studies of treatment for cardiovascular disease was variable. Cross-model validation was reported in 55 % of the reviewed studies, though the level of detail provided varied considerably. We found that very few studies documented other types of validity, and only 6 % of the reviewed articles reported a calibration process. Considering the above findings, we propose a comprehensive model performance evaluation framework (checklist), informed by a review of best-practice guidelines. This framework provides a basis for more accurate and consistent documentation of model performance evaluation. This will improve the peer review process and the comparability of modelling studies. Recognising the fundamental role of decision analytic models in informing public funding decisions, the proposed

  19. Development, validation and implementation of a quantitative food frequency questionnaire to assess habitual vitamin D intake

    DEFF Research Database (Denmark)

    Kiely, M.; Collins, A.; Lucey, A. J.

    2016-01-01

    Background A well-designed, validated quantitative food frequency questionnaire (FFQ) could offer an efficient and cost-effective method for assessing habitual vitamin D intake. The present study aimed to describe the development, validation and implementation of a vitamin D FFQ. Methods National...

  20. Extracting 3D Parametric Curves from 2D Images of Helical Objects.

    Science.gov (United States)

    Willcocks, Chris G; Jackson, Philip T G; Nelson, Carl J; Obara, Boguslaw

    2017-09-01

    Helical objects occur in medicine, biology, cosmetics, nanotechnology, and engineering. Extracting a 3D parametric curve from a 2D image of a helical object has many practical applications, in particular being able to extract metrics such as tortuosity, frequency, and pitch. We present a method that is able to straighten the image object and derive a robust 3D helical curve from peaks in the object boundary. The algorithm has a small number of stable parameters that require little tuning, and the curve is validated against both synthetic and real-world data. The results show that the extracted 3D curve comes within close Hausdorff distance to the ground truth, and has near identical tortuosity for helical objects with a circular profile. Parameter insensitivity and robustness against high levels of image noise are demonstrated thoroughly and quantitatively.

  1. A 3D complex containing novel 2D CuII-azido layers: Structure, magnetic properties and effects of “Non-innocent” reagent

    International Nuclear Information System (INIS)

    Gao, Xue-Miao; Guo, Qian; Zhao, Jiong-Peng; Liu, Fu-Chen

    2012-01-01

    A novel copper-azido coordination polymer, [Cu 2 (N 3 ) 3 (L)] n (1, HL=pyrazine-2-carboxylic acid), has been synthesized by hydrothermal reaction with “Non-innocent” reagent in the aqueous solution. In the reaction system, Cu II ions are avoided to reduce to Cu I ions due to the existence of Nd III . It is found that the complex is a 3D structure based on two double EO azido bridged trimmers and octahedron Cu II ions, in which the azide ligands take on EO and μ 1,1,3 mode to form Cu II -azido 2D layers, furthermore L ligands pillar 2D layers into an infinite 3D framework with the Schläfli symbol of {4;6 2 }4{4 2 ;6 12 ;8 10 ;10 4 }{4 2 ;6 4 }. Magnetic studies revealed that the interactions between the Cu II ions in the trimmer are ferromagnetic for the Cu–N–Cu angle nearly 98°, while the interactions between the trimmer and octahedron Cu II ion are antiferromgantic and result in an antiferromagnetic state. - Graphical abstract: A 3D complex containing novel 2D Cu II -azido layers, [Cu 2 (N 3 ) 3 (L)] n (HL=pyrazine-2-carboxylic acid), was synthesized by hydrothermal reaction and exhibit interesting structure and magnetic properties. Highlights: ► “Non-innocent” reagents plays a key role in the process of formation of this complex. ► 2D layer is formed only by Cu II ions and azido ligands. ► Pyrazine-2-carboxylate ligands reinforce 2D layers and pillar them into an infinite 3D framework. ► Magnetic study indicates that alternating FM–AF coupling exists in the complex.

  2. 2.5-D frequency-domain viscoelastic wave modelling using finite-element method

    Science.gov (United States)

    Zhao, Jian-guo; Huang, Xing-xing; Liu, Wei-fang; Zhao, Wei-jun; Song, Jian-yong; Xiong, Bin; Wang, Shang-xu

    2017-10-01

    2-D seismic modelling has notable dynamic information discrepancies with field data because of the implicit line-source assumption, whereas 3-D modelling suffers from a huge computational burden. The 2.5-D approach is able to overcome both of the aforementioned limitations. In general, the earth model is treated as an elastic material, but the real media is viscous. In this study, we develop an accurate and efficient frequency-domain finite-element method (FEM) for modelling 2.5-D viscoelastic wave propagation. To perform the 2.5-D approach, we assume that the 2-D viscoelastic media are based on the Kelvin-Voigt rheological model and a 3-D point source. The viscoelastic wave equation is temporally and spatially Fourier transformed into the frequency-wavenumber domain. Then, we systematically derive the weak form and its spatial discretization of 2.5-D viscoelastic wave equations in the frequency-wavenumber domain through the Galerkin weighted residual method for FEM. Fixing a frequency, the 2-D problem for each wavenumber is solved by FEM. Subsequently, a composite Simpson formula is adopted to estimate the inverse Fourier integration to obtain the 3-D wavefield. We implement the stiffness reduction method (SRM) to suppress artificial boundary reflections. The results show that this absorbing boundary condition is valid and efficient in the frequency-wavenumber domain. Finally, three numerical models, an unbounded homogeneous medium, a half-space layered medium and an undulating topography medium, are established. Numerical results validate the accuracy and stability of 2.5-D solutions and present the adaptability of finite-element method to complicated geographic conditions. The proposed 2.5-D modelling strategy has the potential to address modelling studies on wave propagation in real earth media in an accurate and efficient way.

  3. Development of a Quasi-3D Multiscale Modeling Framework: Motivation, basic algorithm and preliminary results

    Directory of Open Access Journals (Sweden)

    Joon-Hee Jung

    2010-11-01

    Full Text Available A new framework for modeling the atmosphere, which we call the quasi-3D (Q3D multi-scale modeling framework (MMF, is developed with the objective of including cloud-scale three-dimensional effects in a GCM without necessarily using a global cloud-resolving model (CRM. It combines a GCM with a Q3D CRM that has the horizontal domain consisting of two perpendicular sets of channels, each of which contains a locally 3D grid-point array. For computing efficiency, the widths of the channels are chosen to be narrow. Thus, it is crucial to select a proper lateral boundary condition to realistically simulate the statistics of cloud and cloud-associated processes. Among the various possibilities, a periodic lateral boundary condition is chosen for the deviations from background fields that are obtained by interpolations from the GCM grid points. Since the deviations tend to vanish as the GCM grid size approaches that of the CRM, the whole system of the Q3D MMF can converge to a fully 3D global CRM. Consequently, the horizontal resolution of the GCM can be freely chosen depending on the objective of application, without changing the formulation of model physics. To evaluate the newly developed Q3D CRM in an efficient way, idealized experiments have been performed using a small horizontal domain. In these tests, the Q3D CRM uses only one pair of perpendicular channels with only two grid points across each channel. Comparing the simulation results with those of a fully 3D CRM, it is concluded that the Q3D CRM can reproduce most of the important statistics of the 3D solutions, including the vertical distributions of cloud water and precipitants, vertical transports of potential temperature and water vapor, and the variances and covariances of dynamical variables. The main improvement from a corresponding 2D simulation appears in the surface fluxes and the vorticity transports that cause the mean wind to change. A comparison with a simulation using a coarse

  4. 2D-3D rigid registration to compensate for prostate motion during 3D TRUS-guided biopsy.

    Science.gov (United States)

    De Silva, Tharindu; Fenster, Aaron; Cool, Derek W; Gardi, Lori; Romagnoli, Cesare; Samarabandu, Jagath; Ward, Aaron D

    2013-02-01

    Three-dimensional (3D) transrectal ultrasound (TRUS)-guided systems have been developed to improve targeting accuracy during prostate biopsy. However, prostate motion during the procedure is a potential source of error that can cause target misalignments. The authors present an image-based registration technique to compensate for prostate motion by registering the live two-dimensional (2D) TRUS images acquired during the biopsy procedure to a preacquired 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. The authors implemented an intensity-based 2D-3D rigid registration algorithm optimizing the normalized cross-correlation (NCC) metric using Powell's method. The 2D TRUS images acquired during the procedure prior to biopsy gun firing were registered to the baseline 3D TRUS image acquired at the beginning of the procedure. The accuracy was measured by calculating the target registration error (TRE) using manually identified fiducials within the prostate; these fiducials were used for validation only and were not provided as inputs to the registration algorithm. They also evaluated the accuracy when the registrations were performed continuously throughout the biopsy by acquiring and registering live 2D TRUS images every second. This measured the improvement in accuracy resulting from performing the registration, continuously compensating for motion during the procedure. To further validate the method using a more challenging data set, registrations were performed using 3D TRUS images acquired by intentionally exerting different levels of ultrasound probe pressures in order to measure the performance of our algorithm when the prostate tissue was intentionally deformed. In this data set, biopsy scenarios were simulated by extracting 2D frames from the 3D TRUS images and registering them to the baseline 3D image. A graphics processing unit (GPU)-based implementation was used to improve the

  5. Validation for 2D/3D registration II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set

    International Nuclear Information System (INIS)

    Gendrin, Christelle; Markelj, Primoz; Pawiro, Supriyanto Ardjo; Spoerk, Jakob; Bloch, Christoph; Weber, Christoph; Figl, Michael; Bergmann, Helmar; Birkfellner, Wolfgang; Likar, Bostjan; Pernus, Franjo

    2011-01-01

    Purpose: A new gold standard data set for validation of 2D/3D registration based on a porcine cadaver head with attached fiducial markers was presented in the first part of this article. The advantage of this new phantom is the large amount of soft tissue, which simulates realistic conditions for registration. This article tests the performance of intensity- and gradient-based algorithms for 2D/3D registration using the new phantom data set. Methods: Intensity-based methods with four merit functions, namely, cross correlation, rank correlation, correlation ratio, and mutual information (MI), and two gradient-based algorithms, the backprojection gradient-based (BGB) registration method and the reconstruction gradient-based (RGB) registration method, were compared. Four volumes consisting of CBCT with two fields of view, 64 slice multidetector CT, and magnetic resonance-T1 weighted images were registered to a pair of kV x-ray images and a pair of MV images. A standardized evaluation methodology was employed. Targets were evenly spread over the volumes and 250 starting positions of the 3D volumes with initial displacements of up to 25 mm from the gold standard position were calculated. After the registration, the displacement from the gold standard was retrieved and the root mean square (RMS), mean, and standard deviation mean target registration errors (mTREs) over 250 registrations were derived. Additionally, the following merit properties were computed: Accuracy, capture range, number of minima, risk of nonconvergence, and distinctiveness of optimum for better comparison of the robustness of each merit. Results: Among the merit functions used for the intensity-based method, MI reached the best accuracy with an RMS mTRE down to 1.30 mm. Furthermore, it was the only merit function that could accurately register the CT to the kV x rays with the presence of tissue deformation. As for the gradient-based methods, BGB and RGB methods achieved subvoxel accuracy (RMS m

  6. A computational framework for automation of point defect calculations

    International Nuclear Information System (INIS)

    Goyal, Anuj; Gorai, Prashun; Peng, Haowei

    2017-01-01

    We have developed a complete and rigorously validated open-source Python framework to automate point defect calculations using density functional theory. Furthermore, the framework provides an effective and efficient method for defect structure generation, and creation of simple yet customizable workflows to analyze defect calculations. This package provides the capability to compute widely-accepted correction schemes to overcome finite-size effects, including (1) potential alignment, (2) image-charge correction, and (3) band filling correction to shallow defects. Using Si, ZnO and In2O3 as test examples, we demonstrate the package capabilities and validate the methodology.

  7. 3D hybrid-porous carbon derived from carbonization of metal organic frameworks for high performance supercapacitors

    Science.gov (United States)

    Bao, Weizhai; Mondal, Anjon Kumar; Xu, Jing; Wang, Chengyin; Su, Dawei; Wang, Guoxiu

    2016-09-01

    We report a rational design and synthesis of 3D hybrid-porous carbon with a hierarchical pore architecture for high performance supercapacitors. It contains micropores (<2 nm diameter) and mesopores (2-4 nm), derived from carbonization of unique porous metal organic frameworks (MOFs). Owning to the synergistic effect of micropores and mesopores, the hybrid-porous carbon has exceptionally high ion-accessible surface area and low ion diffusion resistance, which is desired for supercapacitor applications. When applied as electrode materials in supercapacitors, 3D hybrid-porous carbon demonstrates a specific capacitance of 332 F g-1 at a constant charge/discharge current of 500 mA g-1. The supercapacitors can endure more than 10,000 cycles without degradation of capacitance.

  8. Experimental validation of Villain's conjecture about magnetic ordering in quasi-1D helimagnets

    Energy Technology Data Exchange (ETDEWEB)

    Cinti, F., E-mail: fabio.cinti@fi.infn.i [CNISM and Department of Physics, University of Florence, 50019 Sesto Fiorentino (Italy); CNR-INFM S3 National Research Center, I-41100 Modena (Italy); Rettori, A. [CNISM and Department of Physics, University of Florence, 50019 Sesto Fiorentino (Italy); CNR-INFM S3 National Research Center, I-41100 Modena (Italy); Pini, M.G. [ISC-CNR, Via Madonna del Piano 10, I-50019 Sesto Fiorentino (Italy); Mariani, M.; Micotti, E. [Department of Physics A. Volta and CNR-INFM, University of Pavia, Via Bassi 6, I-27100 Pavia (Italy); Lascialfari, A. [Department of Physics A. Volta and CNR-INFM, University of Pavia, Via Bassi 6, I-27100 Pavia (Italy); Institute of General Physiology and Biological Chemistry, University of Milano, Via Trentacoste 2, I-20134 Milano (Italy); CNR-INFM S3 National Research Center, I-41100 Modena (Italy); Papinutto, N. [CIMeC, University of Trento, Via delle Regole, 101 38060 Mattarello (Italy); Department of Physics A. Volta and CNR-INFM, University of Pavia, Via Bassi 6, I-27100 Pavia (Italy); Amato, A. [Paul Scherrer Institute, CH-5232 Villingen PSI (Switzerland); Caneschi, A.; Gatteschi, D. [INSTM R.U. Firenze and Department of Chemistry, University of Florence, Via della Lastruccia 3, I-50019 Sesto Fiorentino (Italy); Affronte, M. [CNR-INFM S3 National Research Center, I-41100 Modena (Italy); Department of Physics, University of Modena and Reggio Emilia Via Campi 213/A, I-41100 Modena (Italy)

    2010-05-15

    Low-temperature magnetic susceptibility, zero-field muon spin resonance and specific heat measurements have been performed in the quasi-one-dimensional (1D) molecular helimagnetic compound Gd(hfac){sub 3}NITEt. The specific heat presents two anomalies at T{sub 0}=2.19(2)K and T{sub N}=1.88(2)K, while susceptibility and zero-field muon spin resonance show anomalies only at T{sub N}=1.88(2)K. The results suggest an experimental validation of Villain's conjecture of a two-step magnetic ordering in quasi-1D XY helimagnets: the paramagnetic phase and the helical spin solid phases are separated by a chiral spin liquid, where translational invariance is broken without violation of rotational invariance.

  9. Validation and comparison of EuroQoL-5 dimension (EQ-5D) and Short Form-6 dimension (SF-6D) among stable angina patients

    OpenAIRE

    Wu, Jing; Han, Yuerong; Zhao, Fei-Li; Zhou, Jin; Chen, Zhijun; Sun, He

    2014-01-01

    Objectives Several preference-based health-related quality of life (HRQoL) instruments have been published and widely used in different populations. However no consensus has emerged regarding the most appropriate instrument in therapeutic area of stable angina. This study compared and validated the psychometric properties of two generic preference-based instruments, the EQ-5D and SF-6D, among Chinese stable angina patients. Methods Convergent validity of the EQ-5D and SF-6D was examined with ...

  10. A validation analysis of two self-reported HAM-D6 versions

    DEFF Research Database (Denmark)

    Bech, P; Wilson, P; Wessel, T

    2009-01-01

    the unidimensionality of this administration form in patients with mild-to-moderate depression. METHOD: The item response theory analysis of Mokken was used to test the unidimensionality of both the Interactive Voice Recording System (IVRS) version of the HAM-D(6) and a paper-and-pencil self-reported version (S-HAM-D(6......OBJECTIVE: The six items of the clinician-administrated Hamilton Depression Scale (HAM-D(6)) cover the core items of depressive states reflecting the antidepressive effect of medication. In this study, the two self-reported versions of the HAM-D(6) have been psychometrically validated to ensure...

  11. Neutronics experimental validation of the Jules Horowitz reactor fuel by interpretation of the VALMONT experimental program-transposition of the uncertainties on the reactivity of JHR with JEF2.2 and JEFF3.1.1

    International Nuclear Information System (INIS)

    Leray, O.; Hudelot, J.P.; Doederlein, C.; Vaglio-Gaudard, C.; Antony, M.; Santamarina, A.; Bernard, D.

    2012-01-01

    The new European material testing Jules Horowitz Reactor (JHR), currently under construction in Cadarache center (CEA France), will use LEU (20% enrichment in 235 U) fuels (U 3 Si 2 for the start up and UMoAl in the future) which are quite different from the industrial oxide fuel, for which an extensive neutronics experimental validation database has been established. The HORUS3D/N neutronics calculation scheme, used for the design and safety studies of the JHR, is being developed within the framework of a rigorous verification-numerical validation-experimental validation methodology. In this framework, the experimental VALMONT (Validation of Aluminium Molybdenum uranium fuel for Neutronics) program has been performed in the MINERVE facility of CEA Cadarache (France), in order to qualify the capability of HORUS3D/N to accurately calculate the reactivity of the JHR reactor. The MINERVE facility using the oscillation technique provides accurate measurements of reactivity effect of samples. The VALMONT program includes oscillations of samples of UAl ∞ /Al and UMo/Al with enrichments ranging from 0.2% to 20% and Uranium densities from 2.2 to 8 g/cm 3 . The geometry of the samples and the pitch of the experimental lattice ensure maximum representativeness with the neutron spectrum expected for JHR. By comparing the effect of the sample with the one of a known fuel specimen, the reactivity effect can be measured in absolute terms and be compared to computational results. Special attention was paid to the rigorous determination and reduction of the experimental uncertainties. The calculational analysis of the VALMONT results was performed with the French deterministic code APOLLO2. A comparison of the impact of the different calculation methods, data libraries and energy meshes that were tested is presented. The interpretation of the VALMONT experimental program allowed the experimental validation of JHR fuel UMoAl8 (with an enrichment of 19.75% 235 U) by the Minerve

  12. 2D-3D registration for cranial radiation therapy using a 3D kV CBCT and a single limited field-of-view 2D kV radiograph.

    Science.gov (United States)

    Munbodh, Reshma; Knisely, Jonathan Ps; Jaffray, David A; Moseley, Douglas J

    2018-05-01

    We present and evaluate a fully automated 2D-3D intensity-based registration framework using a single limited field-of-view (FOV) 2D kV radiograph and a 3D kV CBCT for 3D estimation of patient setup errors during brain radiotherapy. We evaluated two similarity measures, the Pearson correlation coefficient on image intensity values (ICC) and maximum likelihood measure with Gaussian noise (MLG), derived from the statistics of transmission images. Pose determination experiments were conducted on 2D kV radiographs in the anterior-posterior (AP) and left lateral (LL) views and 3D kV CBCTs of an anthropomorphic head phantom. In order to minimize radiation exposure and exclude nonrigid structures from the registration, limited FOV 2D kV radiographs were employed. A spatial frequency band useful for the 2D-3D registration was identified from the bone-to-no-bone spectral ratio (BNBSR) of digitally reconstructed radiographs (DRRs) computed from the 3D kV planning CT of the phantom. The images being registered were filtered accordingly prior to computation of the similarity measures. We evaluated the registration accuracy achievable with a single 2D kV radiograph and with the registration results from the AP and LL views combined. We also compared the performance of the 2D-3D registration solutions proposed to that of a commercial 3D-3D registration algorithm, which used the entire skull for the registration. The ground truth was determined from markers affixed to the phantom and visible in the CBCT images. The accuracy of the 2D-3D registration solutions, as quantified by the root mean squared value of the target registration error (TRE) calculated over a radius of 3 cm for all poses tested, was ICC AP : 0.56 mm, MLG AP : 0.74 mm, ICC LL : 0.57 mm, MLG LL : 0.54 mm, ICC (AP and LL combined): 0.19 mm, and MLG (AP and LL combined): 0.21 mm. The accuracy of the 3D-3D registration algorithm was 0.27 mm. There was no significant difference in mean TRE for the 2D-3D registration

  13. Measurement of the hyperfine structure of the 4d2D3/2,5/2 levels and isotope shifts of the 4p2P3/2->4d2D3/2 and 4p2P3/2->4d2D5/2 transitions in gallium 69 and 71

    International Nuclear Information System (INIS)

    Rehse, Steven J.; Fairbank, William M.; Lee, Siu Au

    2001-01-01

    The hyperfine structure of the 4d 2 D 3/2,5/2 levels of 69,71 Ga is determined. The 4p 2 P 3/2 ->4d 2 D 3/2 (294.50-nm) and 4p 2 P 3/2 ->4d 2 D 5/2 (294.45-nm) transitions are studied by laser-induced fluorescence in an atomic Ga beam. The hyperfine A constant measured for the 4d 2 D 5/2 level is 77.3±0.9 MHz for 69 Ga and 97.9± 0.7 MHz for 71 Ga (3σ errors). The A constant measured for the 4d 2 D 3/2 level is -36.3±2.2 MHz for 69 Ga and -46.2±3.8 MHz for 71 Ga. These measurements correct sign errors in the previous determination of these constants. For 69 Ga the hyperfine B constants measured for the 4d 2 D 5/2 and the 4d 2 D 3/2 levels are 5.3±4.1 MHz and 4.6±4.2 MHz, respectively. The isotope shift is determined to be 114±8 MHz for the 4p 2 P 3/2 ->4d 2 D 3/2 transition and 115±7 MHz for the 4p 2 P 3/2 ->4d 2 D 5/2 transition. The lines of 71 Ga are shifted to the blue. This is in agreement with previous measurement. [copyright] 2001 Optical Society of America

  14. Experimental investigation of H2/D2 isotope separation by cryo-adsorption in metal-organic frameworks

    International Nuclear Information System (INIS)

    Teufel, Julia Sonja

    2012-01-01

    Light-gas isotopes differ in their adsorption behavior under cryogenic conditions in nanoporous materials due to their difference in zero-point energy. However, the applicability of these cryo-effects for the separation of isotope mixtures is still lacking an experimental proof. The current work describes the first experimentally obtained H 2 /D 2 selectivity values of nanoporous materials measured by applying isotope mixtures in low-temperature thermal desorption spectroscopy (TDS). The dissertation contains the following key points: 1) A proof of the experimental method, i.e. it is shown that TDS leads to reasonable selectivity values. 2) A series of small-pore MFU-4 derivatives (MOFs) is shown to separate isotope mixtures by quantum sieving, i.e. by the difference in the adsorption kinetics. The influence of the pore size on the selectivity is studied systematically for this series. 3) Two MOFs with pores much larger than the kinetic diameter of H 2 do not exhibit kinetic quantum sieving. However, if the MOFs are exposed to an isotope mixture, deuterium adsorbs preferentially at the adsorption sites with high heats of adsorption. According to the experimental results, these strong adsorption sites can be every selective for deuterium. On the basis of the experimentally obtained selectivity values, technical implementations for H 2 /D 2 light-gas isotope separation by cryo-adsorption are described.

  15. Improvement of 2D ERT measurements conducted along a small earth-filled dyke using 3D topographic data and 3D computation of geometric factors

    Science.gov (United States)

    Bièvre, Grégory; Oxarango, Laurent; Günther, Thomas; Goutaland, David; Massardi, Michael

    2018-06-01

    In the framework of earth-filled dykes characterization and monitoring, Electrical Resistivity Tomography (ERT) turns out to be a commonly used method. 2D sections are generally acquired along the dyke crest thus putting forward the question of 3D artefacts in the inversion process. This paper proposes a methodology based on 3D direct numerical simulations of the ERT acquisition using a realistic topography of the study site. It allows computing ad hoc geometrical factors which can be used for the inversion of experimental ERT data. The method is first evaluated on a set of synthetic dyke configurations. Then, it is applied to experimental static and time-lapse ERT data set acquired before and after repair works carried out on a leaking zone of an earth-filled canal dyke in the centre of France. The computed geometric factors are lower than the analytic geometric factors in a range between -8% and - 18% for measurements conducted on the crest of the dyke. They exhibit a maximum under-estimation for intermediate electrode spacings in the Wenner and Schlumberger configurations. In the same way, for measurements conducted on the mid-slope of the dyke, the computed geometric factors are higher for short electrode spacings (+18%) and lower for lower for large electrode spacings (-8%). The 2D inversion of the synthetic data with these computed geometric factors provides a significant improvement of the agreement with the original resistivity. Two experimental profiles conducted on the same portion of the dyke but at different elevations also reveal a better agreement using this methodology. The comparison with apparent resistivity from EM31 profiling along the stretch of the dyke also supports this evidence. In the same way, some spurious effects which affected the time-lapse data were removed and improved the global readability of the time-lapse resistivity sections. The benefit on the structural interpretation of ERT images remains moderate but allows a better

  16. Simultaneous Multiple MS Binding Assays Addressing D1 and D2 Dopamine Receptors.

    Science.gov (United States)

    Schuller, Marion; Höfner, Georg; Wanner, Klaus T

    2017-10-09

    MS Binding Assays are a label-free alternative to radioligand binding assays. They provide basically the same capabilities as the latter, but use a non-labeled reporter ligand instead of a radioligand. In contrast to radioligand binding assays, MS Binding Assays offer-owing to the selectivity of mass spectrometric detection-the opportunity to monitor the binding of different reporter ligands at different targets simultaneously. The present study shows a proof of concept for this strategy as exemplified for MS Binding Assays selectively addressing D 1 and D 2 dopamine receptors in a single binding experiment. A highly sensitive, rapid and robust LC-ESI-MS/MS quantification method capable of quantifying both SCH23390 and raclopride, selectively addressing D 1 and D 2 receptors, respectively, was established and validated for this purpose. Based thereon, simultaneous saturation and competition experiments with SCH23390 and raclopride in the presence of both D 1 and D 2 receptors were performed and analyzed by LC-MS/MS within a single chromatographic cycle. The present study thus demonstrates the feasibility of this strategy and the high versatility of MS Binding Assays that appears to surpass that common for conventional radioligand binding assays. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Shaheen, Eman, E-mail: eman.shaheen@uzleuven.be; De Keyzer, Frederik; Bosmans, Hilde; Ongeval, Chantal Van [Department of Radiology, University Hospitals Leuven, Herestraat 49, 3000 Leuven (Belgium); Dance, David R.; Young, Kenneth C. [National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2014-08-15

    Purpose: This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Methods: Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. Results: The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly

  18. The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis

    International Nuclear Information System (INIS)

    Shaheen, Eman; De Keyzer, Frederik; Bosmans, Hilde; Ongeval, Chantal Van; Dance, David R.; Young, Kenneth C.

    2014-01-01

    Purpose: This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Methods: Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. Results: The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly

  19. The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis.

    Science.gov (United States)

    Shaheen, Eman; De Keyzer, Frederik; Bosmans, Hilde; Dance, David R; Young, Kenneth C; Van Ongeval, Chantal

    2014-08-01

    This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly suggestive for malignancy (BIRADS 5

  20. Epimerisation of 2-[18F]-Fluoro-2-Deoxy-D-Glucose under alkaline conditions. A convenient method for the preparation of 2-[18F]-Fluoro-2-Deoxy-D-Mannose

    International Nuclear Information System (INIS)

    Varelis, P.

    1998-01-01

    Full text: The intended goal of our study into the epimerisation of 2-[ 18 F]- fluoro-2-deoxy-D-glucose ([ 18 F]-FDG) was to obtain 2-[ 18 F]-fluoro- 2-deoxy-D-mannose ([ 18 F]-FDM) for the purpose of both development and validation of our analytical methods used to determine the diastereoisomeric excess of [ 18 F]-FDG prepared in our facility. The epimerisation of [ 18 F]-FDG is smoothly effected by heating an aqueous solution of this radiochemical with 1 M aqueous sodium hydroxide at 50-60 deg C for 30 min, which provides an ∼ 1:1 mixture of [ 18 F]-FDG and [ 18 F]-FDM. In addition to the value of this mixture in analytical method development, we also found it useful for gauging the performance of the HPLC column used in the analysis of [ 18 F]-FDG. The aqueous sample matrix can be conveniently changed by azeotropic evaporation of the water with dry acetonitrile. In summary, the base catalysed epimerisation of 2-[ 18 F]-fluoro-2- deoxy-D-glucose provides a convenient and reliable procedure for the preparation 2-[ 18 F]-fluoro-2-deoxy-D-mannose, the stable analogue of which is not commercially available

  1. Validation of Dietary Vitamin D Intake from Two Food Frequency Questionnaires, Using Food Records and the Biomarker 25-Hydroxyvitamin D among Pregnant Women

    Directory of Open Access Journals (Sweden)

    Linnea Bärebring

    2018-06-01

    Full Text Available Our objective was to validate vitamin D intake from a short vitamin D questionnaire (VDQ and a longer online food frequency questionnaire (FFQ against a food record and 25-hydroxyvitamin D (25OHD as a biomarker of vitamin D status, among pregnant women in Sweden. The number of women included was 1125 with VDQ, FFQ and 25OHD, and of those, 64 also completed the food record. Median vitamin D intakes were 3.9 µg by VDQ (p < 0.001, and 5.3 µg by FFQ (p = 0.89, compared to 5.0 µg by food record. Correlations between vitamin D intake from food record and VDQ (rho = 0.51, p < 0.001 or FFQ (rho = 0.49, p < 0.001 were similar. The VDQ and FFQ also had a similar ability to rank the individuals according to vitamin D intake. However, only vitamin D intake from the VDQ was significantly associated with vitamin D status as assessed by 25OHD. The validation coefficient for the VDQ was 0.68 and 0.75 for the FFQ. In conclusion, assessing dietary vitamin D intake is challenging, regardless of the dietary assessment method. The VDQ, that includes only four food items, is a valid, simple and useful tool in assessing vitamin D intake of pregnant women in Sweden, while imposing a minimal burden on women and researchers.

  2. A new metal-organic framework for separation of C2H2/CH4 and CO2/CH4 at room temperature

    Science.gov (United States)

    Duan, Xing; Zhou, You; Lv, Ran; Yu, Ben; Chen, Haodong; Ji, Zhenguo; Cui, Yuanjing; Yang, Yu; Qian, Guodong

    2018-04-01

    A 3D microporous metal-organic framework with open Cu2+ sites and suitable pore space, [Cu2(L)(H2O)2]·(H2O)4(DMF)8 (ZJU-15, H4L = 5,5‧-(9H-carbazole-2,7-diyl)diisophthalic acid; DMF = N,N-dimethylformamide; ZJU = Zhejiang University), has been constructed and characterized. The activated ZJU-15a has three different types of cages and exhibits BET surface area of 1660 m2 g-1, and can separate gas mixture of C2H2/CH4 and CO2/CH4 at room temperature.

  3. Virtual Reality Training for Public Speaking—A QUEST-VR Framework Validation

    Directory of Open Access Journals (Sweden)

    Sandra Poeschl

    2017-06-01

    Full Text Available Good public speaking skills are essential in many professions as well as everyday life, but speech anxiety is a common problem. While it is established that public speaking training in virtual reality (VR is effective, comprehensive studies on the underlying factors that contribute to this success are rare. The “quality evaluation of user-system interaction in virtual reality” framework for evaluation of VR applications is presented that includes system features, user factors, and moderating variables. Based on this framework, variables that are postulated to influence the quality of a public speaking training application were selected for a first validation study. In a cross-sectional, repeated measures laboratory study [N = 36 undergraduate students; 36% men, 64% women, mean age = 26.42 years (SD = 3.42], the effects of task difficulty (independent variable, ability to concentrate, fear of public speaking, and social presence (covariates on public speaking performance (dependent variable in a virtual training scenario were analyzed, using stereoscopic visualization on a screen. The results indicate that the covariates moderate the effect of task difficulty on speech performance, turning it into a non-significant effect. Further interrelations are explored. The presenter’s reaction to the virtual agents in the audience shows a tendency of overlap of explained variance with task difficulty. This underlines the need for more studies dedicated to the interaction of contributing factors for determining the quality of VR public speaking applications.

  4. Zend framework 2.0 by example beginner's guide

    CERN Document Server

    Shasankar, Krishna

    2013-01-01

    Zend Framework 2.0 by Example: Beginner's Guide is a step-by-step guide that aims to empower you to build web applications packed with some really exciting features using Zend Framework 2.0.If you are a PHP Developer who is new to Zend Framework, but you want to get hands-on with the product quickly, this book is for you. Basic knowledge of object oriented programming with PHP is expected.

  5. Nanoporous materials for hydrogen storage and H2/D2 isotope separation

    International Nuclear Information System (INIS)

    Oh, Hyunchul

    2014-01-01

    uptake in Pt doped carbon over pristine carbon is observed indicating a limited role of the spillover effect for practical hydrogen storage. Secondly, the synthesis of a new organic-inorganic hybrid material ''metal doped covalent-organic framework (COF)'' via gas phase infiltration method is presented. In this way, COFs can be used as novel scaffolds for the stabilization of nanoparticles with a nearly mono-dispersed size and homogeneous distribution. At room temperature, the hydrogen storage capacity of Pd doped COFs is enhanced by a factor of 2∝3 compared to the pristine COFs. This significant enhancement of Pd doped COFs can be assigned to the catalytic hydrogenation of organic fragments such as bicyclopentadiene originating from the Pd precursor. Chapter 5 focuses on separation of hydrogen isotopes with nanoporous materials. Separating gaseous mixtures that consist of very similar particles (such as mixture of light gas isotopes or mixtures of noble gases) is one of the challenges in modern separation technology. Especially D 2 /H 2 separation is a difficult task since its size, shape and thermodynamic properties share each other. Recently, quantum sieving in confined space has received increased attention as an efficient method for hydrogen isotope separation. Despite many theoretical calculations, however, it has been difficult to identify a feasible microporous material up to now. Among various porous materials, the novel class of microporous framework materials (COFs, ZIFs and MOFs) is considered as the most promising approach for isotope sieving due to ultra-high porosity and uniform pore size which can be tailored in these materials. Hence, one focus is the investigation of the fundamental correlation between D 2 /H 2 molar ratio and pore size at optimized operating conditions by using different nanoporous frameworks. It reveals that the D 2 /H 2 molar ratio is strongly depending on pore size, pressure and temperature. The experiments indicate clearly that

  6. Developing R&D portfolio business validity simulation model and system.

    Science.gov (United States)

    Yeo, Hyun Jin; Im, Kwang Hyuk

    2015-01-01

    The R&D has been recognized as critical method to take competitiveness by not only companies but also nations with its value creation such as patent value and new product. Therefore, R&D has been a decision maker's burden in that it is hard to decide how much money to invest, how long time one should spend, and what technology to develop which means it accompanies resources such as budget, time, and manpower. Although there are diverse researches about R&D evaluation, business factors are not concerned enough because almost all previous studies are technology oriented evaluation with one R&D technology based. In that, we early proposed R&D business aspect evaluation model which consists of nine business model components. In this research, we develop a simulation model and system evaluating a company or industry's R&D portfolio with business model point of view and clarify default and control parameters to facilitate evaluator's business validity work in each evaluation module by integrate to one screen.

  7. Further Validation of the MMPI-2 And MMPI-2-RF Response Bias Scale: Findings from Disability and Criminal Forensic Settings

    Science.gov (United States)

    Wygant, Dustin B.; Sellbom, Martin; Gervais, Roger O.; Ben-Porath, Yossef S.; Stafford, Kathleen P.; Freeman, David B.; Heilbronner, Robert L.

    2010-01-01

    The present study extends the validation of the Minnesota Multiphasic Personality Inventory-2 (MMPI-2) and the Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF) Response Bias Scale (RBS; R. O. Gervais, Y. S. Ben-Porath, D. B. Wygant, & P. Green, 2007) in separate forensic samples composed of disability claimants and…

  8. QoE-Driven D2D Media Services Distribution Scheme in Cellular Networks

    Directory of Open Access Journals (Sweden)

    Mingkai Chen

    2017-01-01

    Full Text Available Device-to-device (D2D communication has been widely studied to improve network performance and considered as a potential technological component for the next generation communication. Considering the diverse users’ demand, Quality of Experience (QoE is recognized as a new degree of user’s satisfaction for media service transmissions in the wireless communication. Furthermore, we aim at promoting user’s Mean of Score (MOS value to quantify and analyze user’s QoE in the dynamic cellular networks. In this paper, we explore the heterogeneous media service distribution in D2D communications underlaying cellular networks to improve the total users’ QoE. We propose a novel media service scheme based on different QoE models that jointly solve the massive media content dissemination issue for cellular networks. Moreover, we also investigate the so-called Media Service Adaptive Update Scheme (MSAUS framework to maximize users’ QoE satisfaction and we derive the popularity and priority function of different media service QoE expression. Then, we further design Media Service Resource Allocation (MSRA algorithm to schedule limited cellular networks resource, which is based on the popularity function to optimize the total users’ QoE satisfaction and avoid D2D interference. In addition, numerical simulation results indicate that the proposed scheme is more effective in cellular network content delivery, which makes it suitable for various media service propagation.

  9. SU-E-T-231: Cross-Validation of 3D Gamma Comparison Tools

    International Nuclear Information System (INIS)

    Alexander, KM; Jechel, C; Pinter, C; Lasso, A; Fichtinger, G; Salomons, G; Schreiner, LJ

    2015-01-01

    Purpose: Moving the computational analysis for 3D gel dosimetry into the 3D Slicer (www.slicer.org) environment has made gel dosimetry more clinically accessible. To ensure accuracy, we cross-validate the 3D gamma comparison module in 3D Slicer with an independently developed algorithm using simulated and measured dose distributions. Methods: Two reference dose distributions were generated using the Varian Eclipse treatment planning system. The first distribution consisted of a four-field box irradiation delivered to a plastic water phantom and the second, a VMAT plan delivered to a gel dosimeter phantom. The first reference distribution was modified within Eclipse to create an evaluated dose distribution by spatially shifting one field by 3mm, increasing the monitor units of the second field, applying a dynamic wedge for the third field, and leaving the fourth field unchanged. The VMAT plan was delivered to a gel dosimeter and the evaluated dose in the gel was calculated from optical CT measurements. Results from the gamma comparison tool built into the SlicerRT toolbox were compared to results from our in-house gamma algorithm implemented in Matlab (via MatlabBridge in 3D Slicer). The effects of noise, resolution and the exchange of reference and evaluated designations on the gamma comparison were also examined. Results: Perfect agreement was found between the gamma results obtained using the SlicerRT tool and our Matlab implementation for both the four-field box and gel datasets. The behaviour of the SlicerRT comparison with respect to changes in noise, resolution and the role of the reference and evaluated dose distributions was consistent with previous findings. Conclusion: Two independently developed gamma comparison tools have been cross-validated and found to be identical. As we transition our gel dosimetry analysis from Matlab to 3D Slicer, this validation serves as an important test towards ensuring the consistency of dose comparisons using the 3D Slicer

  10. Color constancy in 3D-2D face recognition

    Science.gov (United States)

    Meyer, Manuel; Riess, Christian; Angelopoulou, Elli; Evangelopoulos, Georgios; Kakadiaris, Ioannis A.

    2013-05-01

    Face is one of the most popular biometric modalities. However, up to now, color is rarely actively used in face recognition. Yet, it is well-known that when a person recognizes a face, color cues can become as important as shape, especially when combined with the ability of people to identify the color of objects independent of illuminant color variations. In this paper, we examine the feasibility and effect of explicitly embedding illuminant color information in face recognition systems. We empirically examine the theoretical maximum gain of including known illuminant color to a 3D-2D face recognition system. We also investigate the impact of using computational color constancy methods for estimating the illuminant color, which is then incorporated into the face recognition framework. Our experiments show that under close-to-ideal illumination estimates, one can improve face recognition rates by 16%. When the illuminant color is algorithmically estimated, the improvement is approximately 5%. These results suggest that color constancy has a positive impact on face recognition, but the accuracy of the illuminant color estimate has a considerable effect on its benefits.

  11. Metal organic framework Cu9Cl2(cpa)6 as tunable molecular magnet

    Science.gov (United States)

    Hamilton, Heather S. C.; Farmer, William M.; Skinner, Samuel F.; ter Haar, Leonard W.

    2018-05-01

    Chemical modifications of the magnetic metal organic framework (MOF) Cu9X2(cpa)6.42H2O (X = F, Cl, Br; cpa = anion of 2-carboxypentonicacid) have been investigated as a means of modifying, in a tunable manner, the magnetism of this 2-D material best described as a triangles-in-triangles (TIT) or triangulated-Kagomé-latttice (TKL). Since numerous theoretical studies have already attempted to describe the enigmatic ground state of this Heisenberg lattice, tunable chemical modifications should provide an excellent opportunity to expand this class of materials for studies concerning fundamental physics of frustrated spins, and applications such as adiabatic demagnetization refrigeration (ADR) that depend on the magnetocaloric effect (MCE). The chemical modification investigated is the intercalation of d- and f-orbital ions into the voids of the framework (channels of nearly 20 Å diameter). Magnetic measurements in the temperature range 1.8 - 300 K confirm signature features of TKL magnetism in intercalated samples persist, specifically: i) large negative Weiss constant (θCW); ii) absence of a phase transition down to 1.8 K; iii) minimum in χMT; iv) low temperature χMT values increasingly divergent at low fields indicating net ferromagnetic correlations; and, v) increasing field dependence of magnetization at low temperatures suggestive of intermediate plateaus, or ferrimagnetism, not saturation.

  12. Reliability and validity of the EQ-5D-3L for Kashin-Beck disease in China.

    Science.gov (United States)

    Fang, Hua; Farooq, Umer; Wang, Dimiao; Yu, Fangfang; Younus, Mohammad Imran; Guo, Xiong

    2016-01-01

    Kashin-Beck Disease (KBD) is an endemic osteoarthropathy in areas which extend from the North-East to the South-West of China. Most of the patients with KBD suffer multiple dysfunctions in major joints causing decreased health status. However because of their low education level and unique living habits, it is hard to find tools to measure the health-related quality of life (HRQOL). European quality of life (EQ-5D-3L) patient-reported instrument is widely used to measure HRQOL. This study aimed to establish the validity and reliability of the Chinese version of the EQ-5D-3L for evaluating HRQOL of KBD individuals in rural area. 368 individuals who were suffering from KBD were recruited through stratified multistage random sampling from Shaanxi province, China. The EQ-5D-3L and the WHOQOL-BREF were administrated in each individual by face to face interview. Test-retest reliability was assessed at 10-14 days intervals. The test-retest reliability was measured by calculating the Kappa coefficients for EQ-5D-3L five dimensions. For the EQ VAS, the intraclass correlation coefficient (ICC) was computed. Convergent and divergent analysis, construct validity was established using Spearman's rank correlation between the EQ-5D-3L and the WHOQOL-BREF. Known groups' validity was examined by comparing groups with a priori expected differences in health-related quality of life (HRQOL). For 362 individuals (98%), comprehensive data of all the EQ-5D-3L dimensions were available. Kappa values of the EQ-5D-3L five items ranged from 0.324 to 0.554. ICC of the EQ VAS was 0.497. For convergent validity, the three items (self-care, usual activity, and mobility) of EQ-5D-3L, index scores, and VAS showed moderate correlations with the physical health domain of the WHOQOL-BREF (r absolute value ranged from 0.339 to 0.475). For divergent validity, the 5 items of EQ-5D-3L showed weak or no correlations with environment and social relationship domains of WHOQOL-BREF. The Chinese EQ-5D-3L

  13. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging

    International Nuclear Information System (INIS)

    Martin, Spencer; Rodrigues, George; Gaede, Stewart; Brophy, Mark; Barron, John L; Beauchemin, Steven S; Palma, David; Louie, Alexander V; Yu, Edward; Yaremko, Brian; Ahmad, Belal

    2015-01-01

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development. (paper)

  14. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging

    Science.gov (United States)

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart

    2015-02-01

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  15. Investigation on the neutron beam characteristics for boron neutron capture therapy with 3D and 2D transport calculations

    International Nuclear Information System (INIS)

    Kodeli, I.; Diop, C.M.; Nimal, J.C.

    1994-01-01

    In the framework of future Boron Neutron Capture Therapy (BNCT) experiments, where cells and animals irradiations are planned at the research reactor of Strasbourg University, the feasibility to obtain a suitable epithermal neutron beam is investigated. The neutron fluence and spectra calculations in the reactor are performed using the 3D Monte Carlo code TRIPOLI-3 and the 2D SN code TWODANT. The preliminary analysis of Al 2 O 3 and Al-Al 2 O 3 filters configurations are carried out in an attempt to optimize the flux characteristics in the beam tube facility. 7 figs., 7 refs

  16. Framework for Automated GD&T Inspection Using 3D Scanner

    Science.gov (United States)

    Pathak, Vimal Kumar; Singh, Amit Kumar; Sivadasan, M.; Singh, N. K.

    2018-04-01

    Geometric Dimensioning and Tolerancing (GD&T) is a typical dialect that helps designers, production faculty and quality monitors to convey design specifications in an effective and efficient manner. GD&T has been practiced since the start of machine component assembly but without overly naming it. However, in recent times industries have started increasingly emphasizing on it. One prominent area where most of the industries struggle with is quality inspection. Complete inspection process is mostly human intensive. Also, the use of conventional gauges and templates for inspection purpose highly depends on skill of workers and quality inspectors. In industries, the concept of 3D scanning is not new but is used only for creating 3D drawings or modelling of physical parts. However, the potential of 3D scanning as a powerful inspection tool is hardly explored. This study is centred on designing a procedure for automated inspection using 3D scanner. Linear, geometric and dimensional inspection of the most popular test bar-stepped bar, as a simple example was also carried out as per the new framework. The new generation engineering industries would definitely welcome this automated inspection procedure being quick and reliable with reduced human intervention.

  17. 24,25,28-Trihydroxyvitamin D2 and 24,25,26-trihydroxyvitamin D2: Novel metabolites of vitamin D2

    International Nuclear Information System (INIS)

    Reddy, G.S.; Tserng, K.

    1990-01-01

    Understanding of the inactivation pathways of 25-hydroxyvitamin D 2 and 24-hydroxyvitamin D 2 , the two physiologically significant monohydroxylated metabolites of vitamin D 2 , is of importance, especially during hypervitaminosis D 2 . At present, little information is available regarding the inactivation pathway of 25-hydroxyvitamin D 2 except its further metabolism into 24,25-dihydroxyvitamin D 2 . In our present study, the authors investigated the metabolic fate of 25-hydroxyvitamin D 2 in the isolated perfused rat kidney and demonstrated its conversion not only into 24,25-dihydroxyvitamin D 2 but also into two other new metabolites, namely, 24,25,28-trihydroxyvitamin D 2 and 24,25,26-trihydroxyvitamin D 2 . The structure identification of the new metabolites was established by the techniques of ultraviolet absorption spectrophotometry and mass spectrometry and by the characteristic nature of each new metabolite's susceptibility to sodium metaperiodate oxidation. In order to demonstrate the physiological significance of the two new trihydroxy metabolites of vitamin D 2 , induced hypervitaminosis D 2 in a rat using [3α- 3 H]vitamin D 2 and analyzed its plasma for the various [3α- 3 H]vitamin D 2 metabolites on two different high-pressure liquid chromatography systems. The results indicate that both 24,25,26-trihydroxyvitamin D 2 and 24,25,26-trihydroxyvitamin D 2 circulate in the vitamin D 2 intoxicated rat in significant amounts along with other previously identified monohydroxy and dihydroxy metabolites of vitamin D 2 , namely, 24-hydroxyvitamin D 2 , 25-hydroxyvitamin D 2 , and 24,25-dihydroxyvitamin D 2

  18. Validation of Rheological Models of Typical Structures : an Attempt to Work Out an Insurance-Quality Procedure Validation des modèles rhéologiques sur ouvrages types : une tentative de démarche d'assurance-qualité

    Directory of Open Access Journals (Sweden)

    Meimon Y.

    2006-11-01

    Grenoble (IMG, INSA Lyon, Laboratoire de Génie Civil de Lille (LML, Politecnico Milan, d'autre part de centres techniques et industriels (Électricité de France (EDF, Institut Français du Pétrole (IFP, Laboratoire Central des Ponts et Chaussées de Nantes et de Paris (LCPC, concernent : - un processus complet de validation, que l'on peut comprendre comme une démarche d'assurance-qualité, et qui a été élaboré, de la validation sur essais homogènes en laboratoire à la validation sur problèmes aux limites (fig. 1 ; - la mise en oeuvre de ce processus grâce à l'automatisation partielle de la validation en utilisant un environnement logiciel créé à cet effet (logiciels VALOIS/IFP et MICVAL/LML, et grâce à l'automatisation de la détermination des paramètres de modèles (ADELAP/IFP, PRESS'IDENT/ECL, TRIDENT/INSA Lyon (fig. 2 à 7 : - une reflexion sur la méthodologie de détermination des paramètres de modèles sophistiqués à partir d'essais in situ (le pressiomètre qui a été engagée et a abouti au logiciel PRESS'IDENT ; - une banque d'expérimentations d'enfoncement d'embases dans du sable en laboratoire et en centrifugeuse qui a été créée : essais dans l'appareil triaxial à de forts niveaux de contraintes dont l'originalité consiste dans la variété des chemins de sollicitation testés (LML (fig. 8 ; essais en cuve à faible niveau de contrainte qui ont permis d'analyser la fiabilité des mesures de contraintes dans un massif et le problème délicat de la répétabilité dans différents laboratoires (IMG, INSA Lyon (fig. 9 ; essais en centrifugeuse sur sable dense, lâche moyennement dense dont la répétabilité a été soigneusement étudiée ainsi que l'influence de la forme de l'embase (circulaire, filante . . . (LCPC Nantes (fig. 10. Ces études ont montré la difficulté à collecter des mesures fiables pour la validation des modèles, en particulier en ce qui concerne les mesures de contraintes dans le massif de fondation ; - une

  19. Strategy2D: Turn-based Strategy Video Game Engine for Mobile Devices

    OpenAIRE

    Calvo Villazón, Javier

    2014-01-01

    Multi-platform video game engine for the development of turn-based strategy games for mobile devices. Developed in C++ within the Cocos2d-x framework, It provides a scalable and configurable tool for the creation of this type of games.

  20. The first 3D malonate bridged copper [Cu(O2C–CH2–CO2H)2·2H2O]: Structure, properties and electronic structure

    International Nuclear Information System (INIS)

    Seguatni, A.; Fakhfakh, M.; Smiri, L.S.; Gressier, P.; Boucher, F.; Jouini, N.

    2012-01-01

    A new inorganic-organic compound [Cu(O 2 C–CH 2 –CO 2 H) 2 ·2H 2 O] ([Cumal]) was hydrothermally synthesized and characterized by IR spectroscopy, thermal analysis and single crystal X-ray diffraction. [Cumal] is the first three-dimensional compound existing in the system Cu(II)–malonic acid–H 2 O. Its framework is built up through carboxyl bridged copper where CuO 6 octahedra are elongated with an almost D 4h symmetry (4+2) due to the Jahn–Teller effect. The magnetic properties were studied by measuring its magnetic susceptibility in the temperature range of 2–300 K indicating the existence of weak ferromagnetic interactions. The electronic structure of [Cumal] was calculated within the density functional theory (DFT) framework. Structural features are well reproduced using DFT structural optimizations and the optical spectra, calculated within the dielectric formalism, explain very well the light blue colour of the compound. It is shown that a GGA+U approach with a U eff value of about 6 eV is necessary for a better correlation with the experiment. - Graphical abstract: [Cu(O 2 C–CH 2 –CO 2 H) 2 ·2H 2 O]: the first 3D hybrid organic–inorganic compound built up carboxyl groups. The network presents a diamond-like structure achieved via carboxyl. Highlights: ► A new organic–inorganic material with an unprecedented topology is synthesized. ► Crystallographic structure is determined using single crystal X-ray diffraction. ► Electronic structure is obtained from DFT, GGA+U calculation. ► Framework can be described as formed from CuC 4 tetrahedron sharing four corners. ► This structure can be classified as an extended diamond structure.

  1. A Bayesian framework for adaptive selection, calibration, and validation of coarse-grained models of atomistic systems

    Energy Technology Data Exchange (ETDEWEB)

    Farrell, Kathryn, E-mail: kfarrell@ices.utexas.edu; Oden, J. Tinsley, E-mail: oden@ices.utexas.edu; Faghihi, Danial, E-mail: danial@ices.utexas.edu

    2015-08-15

    A general adaptive modeling algorithm for selection and validation of coarse-grained models of atomistic systems is presented. A Bayesian framework is developed to address uncertainties in parameters, data, and model selection. Algorithms for computing output sensitivities to parameter variances, model evidence and posterior model plausibilities for given data, and for computing what are referred to as Occam Categories in reference to a rough measure of model simplicity, make up components of the overall approach. Computational results are provided for representative applications.

  2. A Bayesian framework for adaptive selection, calibration, and validation of coarse-grained models of atomistic systems

    Science.gov (United States)

    Farrell, Kathryn; Oden, J. Tinsley; Faghihi, Danial

    2015-08-01

    A general adaptive modeling algorithm for selection and validation of coarse-grained models of atomistic systems is presented. A Bayesian framework is developed to address uncertainties in parameters, data, and model selection. Algorithms for computing output sensitivities to parameter variances, model evidence and posterior model plausibilities for given data, and for computing what are referred to as Occam Categories in reference to a rough measure of model simplicity, make up components of the overall approach. Computational results are provided for representative applications.

  3. Risk-Based Tailoring of the Verification, Validation, and Accreditation/Acceptance Processes (Adaptation fondee sur le risque, des processus de verification, de validation, et d’accreditation/d’acceptation)

    Science.gov (United States)

    2012-04-01

    AGARD doivent comporter la dénomination « RTO » ou « AGARD » selon le cas, suivi du numéro de série. Des informations analogues, telles que le titre ...MSG-054 Risk-Based Tailoring of the Verification, Validation, and Accreditation/ Acceptance Processes (Adaptation fondée sur le risque, des...MSG-054 Risk-Based Tailoring of the Verification, Validation, and Accreditation/ Acceptance Processes (Adaptation fondée sur le risque, des

  4. ON SOFT D2-ALGEBRA AND SOFT D2-IDEALS

    OpenAIRE

    S. Subramanian; S. Seethalaksmi

    2018-01-01

    In this paper, we have studied some characterization of soft D2-algebra, kernel, intersection, image, quotient D2-algebra’s and relations ship between D2-algebra and D2-ideals with suitable examples.

  5. 3D dynamic pituitary MR imaging with CAIPIRINHA: Initial experience and comparison with 2D dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fushimi, Yasutaka, E-mail: yfushimi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Okada, Tomohisa; Kanagaki, Mitsunori; Yamamoto, Akira; Kanda, Yumiko; Sakamoto, Ryo [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Hojo, Masato; Takahashi, Jun C.; Miyamoto, Susumu [Department of Neurosurgery, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan)

    2014-10-15

    Objectives: To evaluate the validity of 3D dynamic pituitary MR imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), with special emphasis on demarcation of pituitary posterior lobe and stalk. Methods: Participants comprised 32 patients who underwent dynamic pituitary MR imaging due to pituitary or parasellar lesions. 3D dynamic MR with CAIPIRINHA was performed at 3 T with 20-s-interval, precontrast, 1st to 5th dynamic images. Normalized values and enhanced ratios (dynamic postcontrast image values divided by precontrast ones) were compared between 3D and 2D dynamic MR imaging for patients with visual identification of posterior lobe and stalk. Results: In 3D, stalk was identified in 29 patients and unidentified in 3, and posterior lobe was identified in 28 and unidentified in 4. In 2D, stalk was identified in 26 patients and unidentified in 6 patients, and posterior lobe was identified in 15 and unidentified in 17. Normalized values of pituitary posterior lobe and stalk were higher in 3D than 2D (P < 0.001). No significant difference in enhancement ratio was seen between 3D and 2D. Conclusions: 3D dynamic pituitary MR provided better identification and higher normalized values of pituitary posterior lobe and stalk than 2D.

  6. Detecting spatial patterns of rivermouth processes using a geostatistical framework for near-real-time analysis

    Science.gov (United States)

    Xu, Wenzhao; Collingsworth, Paris D.; Bailey, Barbara; Carlson Mazur, Martha L.; Schaeffer, Jeff; Minsker, Barbara

    2017-01-01

    This paper proposes a geospatial analysis framework and software to interpret water-quality sampling data from towed undulating vehicles in near-real time. The framework includes data quality assurance and quality control processes, automated kriging interpolation along undulating paths, and local hotspot and cluster analyses. These methods are implemented in an interactive Web application developed using the Shiny package in the R programming environment to support near-real time analysis along with 2- and 3-D visualizations. The approach is demonstrated using historical sampling data from an undulating vehicle deployed at three rivermouth sites in Lake Michigan during 2011. The normalized root-mean-square error (NRMSE) of the interpolation averages approximately 10% in 3-fold cross validation. The results show that the framework can be used to track river plume dynamics and provide insights on mixing, which could be related to wind and seiche events.

  7. BurnCase 3D software validation study: Burn size measurement accuracy and inter-rater reliability.

    Science.gov (United States)

    Parvizi, Daryousch; Giretzlehner, Michael; Wurzer, Paul; Klein, Limor Dinur; Shoham, Yaron; Bohanon, Fredrick J; Haller, Herbert L; Tuca, Alexandru; Branski, Ludwik K; Lumenta, David B; Herndon, David N; Kamolz, Lars-P

    2016-03-01

    The aim of this study was to compare the accuracy of burn size estimation using the computer-assisted software BurnCase 3D (RISC Software GmbH, Hagenberg, Austria) with that using a 2D scan, considered to be the actual burn size. Thirty artificial burn areas were pre planned and prepared on three mannequins (one child, one female, and one male). Five trained physicians (raters) were asked to assess the size of all wound areas using BurnCase 3D software. The results were then compared with the real wound areas, as determined by 2D planimetry imaging. To examine inter-rater reliability, we performed an intraclass correlation analysis with a 95% confidence interval. The mean wound area estimations of the five raters using BurnCase 3D were in total 20.7±0.9% for the child, 27.2±1.5% for the female and 16.5±0.1% for the male mannequin. Our analysis showed relative overestimations of 0.4%, 2.8% and 1.5% for the child, female and male mannequins respectively, compared to the 2D scan. The intraclass correlation between the single raters for mean percentage of the artificial burn areas was 98.6%. There was also a high intraclass correlation between the single raters and the 2D Scan visible. BurnCase 3D is a valid and reliable tool for the determination of total body surface area burned in standard models. Further clinical studies including different pediatric and overweight adult mannequins are warranted. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  8. Developing R&D Portfolio Business Validity Simulation Model and System

    Directory of Open Access Journals (Sweden)

    Hyun Jin Yeo

    2015-01-01

    Full Text Available The R&D has been recognized as critical method to take competitiveness by not only companies but also nations with its value creation such as patent value and new product. Therefore, R&D has been a decision maker’s burden in that it is hard to decide how much money to invest, how long time one should spend, and what technology to develop which means it accompanies resources such as budget, time, and manpower. Although there are diverse researches about R&D evaluation, business factors are not concerned enough because almost all previous studies are technology oriented evaluation with one R&D technology based. In that, we early proposed R&D business aspect evaluation model which consists of nine business model components. In this research, we develop a simulation model and system evaluating a company or industry’s R&D portfolio with business model point of view and clarify default and control parameters to facilitate evaluator’s business validity work in each evaluation module by integrate to one screen.

  9. Developing R&D Portfolio Business Validity Simulation Model and System

    Science.gov (United States)

    2015-01-01

    The R&D has been recognized as critical method to take competitiveness by not only companies but also nations with its value creation such as patent value and new product. Therefore, R&D has been a decision maker's burden in that it is hard to decide how much money to invest, how long time one should spend, and what technology to develop which means it accompanies resources such as budget, time, and manpower. Although there are diverse researches about R&D evaluation, business factors are not concerned enough because almost all previous studies are technology oriented evaluation with one R&D technology based. In that, we early proposed R&D business aspect evaluation model which consists of nine business model components. In this research, we develop a simulation model and system evaluating a company or industry's R&D portfolio with business model point of view and clarify default and control parameters to facilitate evaluator's business validity work in each evaluation module by integrate to one screen. PMID:25893209

  10. A Dynamic Multi-Projection-Contour Approximating Framework for the 3D Reconstruction of Buildings by Super-Generalized Optical Stereo-Pairs.

    Science.gov (United States)

    Yan, Yiming; Su, Nan; Zhao, Chunhui; Wang, Liguo

    2017-09-19

    In this paper, a novel framework of the 3D reconstruction of buildings is proposed, focusing on remote sensing super-generalized stereo-pairs (SGSPs). As we all know, 3D reconstruction cannot be well performed using nonstandard stereo pairs, since reliable stereo matching could not be achieved when the image-pairs are collected at a great difference of views, and we always failed to obtain dense 3D points for regions of buildings, and cannot do further 3D shape reconstruction. We defined SGSPs as two or more optical images collected in less constrained views but covering the same buildings. It is even more difficult to reconstruct the 3D shape of a building by SGSPs using traditional frameworks. As a result, a dynamic multi-projection-contour approximating (DMPCA) framework was introduced for SGSP-based 3D reconstruction. The key idea is that we do an optimization to find a group of parameters of a simulated 3D model and use a binary feature-image that minimizes the total differences between projection-contours of the building in the SGSPs and that in the simulated 3D model. Then, the simulated 3D model, defined by the group of parameters, could approximate the actual 3D shape of the building. Certain parameterized 3D basic-unit-models of typical buildings were designed, and a simulated projection system was established to obtain a simulated projection-contour in different views. Moreover, the artificial bee colony algorithm was employed to solve the optimization. With SGSPs collected by the satellite and our unmanned aerial vehicle, the DMPCA framework was verified by a group of experiments, which demonstrated the reliability and advantages of this work.

  11. Quasi 3D dosimetry (EPID, conventional 2D/3D detector matrices)

    International Nuclear Information System (INIS)

    Bäck, A

    2015-01-01

    Patient specific pretreatment measurement for IMRT and VMAT QA should preferably give information with a high resolution in 3D. The ability to distinguish complex treatment plans, i.e. treatment plans with a difference between measured and calculated dose distributions that exceeds a specified tolerance, puts high demands on the dosimetry system used for the pretreatment measurements and the results of the measurement evaluation needs a clinical interpretation. There are a number of commercial dosimetry systems designed for pretreatment IMRT QA measurements. 2D arrays such as MapCHECK ® (Sun Nuclear), MatriXX Evolution (IBA Dosimetry) and OCTAVIOUS ® 1500 (PTW), 3D phantoms such as OCTAVIUS ® 4D (PTW), ArcCHECK ® (Sun Nuclear) and Delta 4 (ScandiDos) and software for EPID dosimetry and 3D reconstruction of the dose in the patient geometry such as EPIDose TM (Sun Nuclear) and Dosimetry Check TM (Math Resolutions) are available. None of those dosimetry systems can measure the 3D dose distribution with a high resolution (full 3D dose distribution). Those systems can be called quasi 3D dosimetry systems. To be able to estimate the delivered dose in full 3D the user is dependent on a calculation algorithm in the software of the dosimetry system. All the vendors of the dosimetry systems mentioned above provide calculation algorithms to reconstruct a full 3D dose in the patient geometry. This enables analyzes of the difference between measured and calculated dose distributions in DVHs of the structures of clinical interest which facilitates the clinical interpretation and is a promising tool to be used for pretreatment IMRT QA measurements. However, independent validation studies on the accuracy of those algorithms are scarce. Pretreatment IMRT QA using the quasi 3D dosimetry systems mentioned above rely on both measurement uncertainty and accuracy of calculation algorithms. In this article, these quasi 3D dosimetry systems and their use in patient specific

  12. MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Juang, T. [Stanford Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  13. MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques

    International Nuclear Information System (INIS)

    Juang, T.

    2016-01-01

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  14. On mode selection and power control for uplink D2D communication in cellular networks

    KAUST Repository

    Ali, Konpal S.

    2015-06-08

    Device-to-device (D2D) communication enables users lying in close proximity to bypass the cellular base station (BS) and transmit to one another directly. This offloads traffic from the cellular network, improves spatial frequency reuse and energy efficiency in the network. We present a comprehensive and tractable analytical framework for D2D-enabled uplink cellular networks with two different flexible mode-selection schemes. The power-control cutoff thresholds of the two communication modes have been decoupled unlike past work on the subject. We find that for a given network, an optimal value exists not only for the biased mode selection criterion, but also for r, the ratio of the power-control cutoff thresholds of the two communication modes, which maximizes spatial spectral efficiency. Also, r turns out to be a more robust parameter for optimizing network performance. Further, it is shown that the second scheme, which prioritizes spatial frequency reuse over the per-user achievable performance compared to the first scheme, achieves almost the same overall network performance; thereby trading per user performance to serve a larger number of users.

  15. On mode selection and power control for uplink D2D communication in cellular networks

    KAUST Repository

    Ali, Konpal S.; Elsawy, Hesham; Alouini, Mohamed-Slim

    2015-01-01

    Device-to-device (D2D) communication enables users lying in close proximity to bypass the cellular base station (BS) and transmit to one another directly. This offloads traffic from the cellular network, improves spatial frequency reuse and energy efficiency in the network. We present a comprehensive and tractable analytical framework for D2D-enabled uplink cellular networks with two different flexible mode-selection schemes. The power-control cutoff thresholds of the two communication modes have been decoupled unlike past work on the subject. We find that for a given network, an optimal value exists not only for the biased mode selection criterion, but also for r, the ratio of the power-control cutoff thresholds of the two communication modes, which maximizes spatial spectral efficiency. Also, r turns out to be a more robust parameter for optimizing network performance. Further, it is shown that the second scheme, which prioritizes spatial frequency reuse over the per-user achievable performance compared to the first scheme, achieves almost the same overall network performance; thereby trading per user performance to serve a larger number of users.

  16. Concise and Accessible Representations for Multidimensional Datasets: Introducing a Framework Based on the nD-EVM and Kohonen Networks

    Directory of Open Access Journals (Sweden)

    Ricardo Pérez-Aguila

    2015-01-01

    Full Text Available A new framework intended for representing and segmenting multidimensional datasets resulting in low spatial complexity requirements and with appropriate access to their contained information is described. Two steps are going to be taken in account. The first step is to specify (n-1D hypervoxelizations, n≥2, as Orthogonal Polytopes whose nth dimension corresponds to color intensity. Then, the nD representation is concisely expressed via the Extreme Vertices Model in the n-Dimensional Space (nD-EVM. Some examples are presented, which, under our methodology, have storing requirements minor than those demanded by their original hypervoxelizations. In the second step, 1-Dimensional Kohonen Networks (1D-KNs are applied in order to segment datasets taking in account their geometrical and topological properties providing a non-supervised way to compact even more the proposed n-Dimensional representations. The application of our framework shares compression ratios, for our set of study cases, in the range 5.6496 to 32.4311. Summarizing, the contribution combines the power of the nD-EVM and 1D-KNs by producing very concise datasets’ representations. We argue that the new representations also provide appropriate segmentations by introducing some error functions such that our 1D-KNs classifications are compared against classifications based only in color intensities. Along the work, main properties and algorithms behind the nD-EVM are introduced for the purpose of interrogating the final representations in such a way that it efficiently obtains useful geometrical and topological information.

  17. Genotet: An Interactive Web-based Visual Exploration Framework to Support Validation of Gene Regulatory Networks.

    Science.gov (United States)

    Yu, Bowen; Doraiswamy, Harish; Chen, Xi; Miraldi, Emily; Arrieta-Ortiz, Mario Luis; Hafemeister, Christoph; Madar, Aviv; Bonneau, Richard; Silva, Cláudio T

    2014-12-01

    Elucidation of transcriptional regulatory networks (TRNs) is a fundamental goal in biology, and one of the most important components of TRNs are transcription factors (TFs), proteins that specifically bind to gene promoter and enhancer regions to alter target gene expression patterns. Advances in genomic technologies as well as advances in computational biology have led to multiple large regulatory network models (directed networks) each with a large corpus of supporting data and gene-annotation. There are multiple possible biological motivations for exploring large regulatory network models, including: validating TF-target gene relationships, figuring out co-regulation patterns, and exploring the coordination of cell processes in response to changes in cell state or environment. Here we focus on queries aimed at validating regulatory network models, and on coordinating visualization of primary data and directed weighted gene regulatory networks. The large size of both the network models and the primary data can make such coordinated queries cumbersome with existing tools and, in particular, inhibits the sharing of results between collaborators. In this work, we develop and demonstrate a web-based framework for coordinating visualization and exploration of expression data (RNA-seq, microarray), network models and gene-binding data (ChIP-seq). Using specialized data structures and multiple coordinated views, we design an efficient querying model to support interactive analysis of the data. Finally, we show the effectiveness of our framework through case studies for the mouse immune system (a dataset focused on a subset of key cellular functions) and a model bacteria (a small genome with high data-completeness).

  18. Developing a theoretical framework for complex community-based interventions.

    Science.gov (United States)

    Angeles, Ricardo N; Dolovich, Lisa; Kaczorowski, Janusz; Thabane, Lehana

    2014-01-01

    Applying existing theories to research, in the form of a theoretical framework, is necessary to advance knowledge from what is already known toward the next steps to be taken. This article proposes a guide on how to develop a theoretical framework for complex community-based interventions using the Cardiovascular Health Awareness Program as an example. Developing a theoretical framework starts with identifying the intervention's essential elements. Subsequent steps include the following: (a) identifying and defining the different variables (independent, dependent, mediating/intervening, moderating, and control); (b) postulating mechanisms how the independent variables will lead to the dependent variables; (c) identifying existing theoretical models supporting the theoretical framework under development; (d) scripting the theoretical framework into a figure or sets of statements as a series of hypotheses, if/then logic statements, or a visual model; (e) content and face validation of the theoretical framework; and (f) revising the theoretical framework. In our example, we combined the "diffusion of innovation theory" and the "health belief model" to develop our framework. Using the Cardiovascular Health Awareness Program as the model, we demonstrated a stepwise process of developing a theoretical framework. The challenges encountered are described, and an overview of the strategies employed to overcome these challenges is presented.

  19. Interactive Classification of Construction Materials: Feedback Driven Framework for Annotation and Analysis of 3d Point Clouds

    Science.gov (United States)

    Hess, M. R.; Petrovic, V.; Kuester, F.

    2017-08-01

    Digital documentation of cultural heritage structures is increasingly more common through the application of different imaging techniques. Many works have focused on the application of laser scanning and photogrammetry techniques for the acquisition of threedimensional (3D) geometry detailing cultural heritage sites and structures. With an abundance of these 3D data assets, there must be a digital environment where these data can be visualized and analyzed. Presented here is a feedback driven visualization framework that seamlessly enables interactive exploration and manipulation of massive point cloud data. The focus of this work is on the classification of different building materials with the goal of building more accurate as-built information models of historical structures. User defined functions have been tested within the interactive point cloud visualization framework to evaluate automated and semi-automated classification of 3D point data. These functions include decisions based on observed color, laser intensity, normal vector or local surface geometry. Multiple case studies are presented here to demonstrate the flexibility and utility of the presented point cloud visualization framework to achieve classification objectives.

  20. Lanthanide metal-organic frameworks

    International Nuclear Information System (INIS)

    Cheng, Peng

    2015-01-01

    This book contains the following nine chapters: lanthanide metal-organic frameworks: syntheses, properties, and potential applications (Stephen Fordham, Xuan Wang, Mathieu Bosch, Hong-Cai Zhou); 2. chiral lanthanide metal-organic frameworks (Weisheng Liu, Xiaoliang Tang); 3. Porous lanthanide metal-organic frameworks for gas storage and separation (Bin Li, Banglin Chen); 4. Luminescent lanthanide metal-organic frameworks (Xue-Zhi Song, Shu-Yan Song, Hong-Jie Zhang); 5. Metal-organic frameworks based on lanthanide clusters (Lian Chen, Feilong Jiang, Kang Zhou, Mingyan Wu, Maochun Hong); 6. metal-organic frameworks with d-f cyanide bridges: structural diversity, bonding regime, and magnetism (Marilena Ferbinteanu, Fanica Cimpoesu, Stefania Tanase); 7. transition-lanthanide heterometal-organic frameworks: synthesis, structures, and properties (Wei Shi, Ke Liu, Peng Cheng); 8: MOFs of uranium and the actinides (Juan Su, Jiesheng Chen); 9. Nanostructured and/or nanoscale lanthanide metal-organic frameworks (Zhonghao Zhang, Zhiping Zheng).

  1. Lanthanide metal-organic frameworks

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Peng (ed.) [Nankai Univ., Tianjin (China). Dept. of Chemistry

    2015-03-01

    This book contains the following nine chapters: lanthanide metal-organic frameworks: syntheses, properties, and potential applications (Stephen Fordham, Xuan Wang, Mathieu Bosch, Hong-Cai Zhou); 2. chiral lanthanide metal-organic frameworks (Weisheng Liu, Xiaoliang Tang); 3. Porous lanthanide metal-organic frameworks for gas storage and separation (Bin Li, Banglin Chen); 4. Luminescent lanthanide metal-organic frameworks (Xue-Zhi Song, Shu-Yan Song, Hong-Jie Zhang); 5. Metal-organic frameworks based on lanthanide clusters (Lian Chen, Feilong Jiang, Kang Zhou, Mingyan Wu, Maochun Hong); 6. metal-organic frameworks with d-f cyanide bridges: structural diversity, bonding regime, and magnetism (Marilena Ferbinteanu, Fanica Cimpoesu, Stefania Tanase); 7. transition-lanthanide heterometal-organic frameworks: synthesis, structures, and properties (Wei Shi, Ke Liu, Peng Cheng); 8: MOFs of uranium and the actinides (Juan Su, Jiesheng Chen); 9. Nanostructured and/or nanoscale lanthanide metal-organic frameworks (Zhonghao Zhang, Zhiping Zheng).

  2. Pathway and Cell-Specific Kappa-Opioid Receptor Modulation of Excitatory-Inhibitory Balance Differentially Gates D1 and D2 Accumbens Neuron Activity

    Science.gov (United States)

    Tejeda, Hugo A.; Wu, Jocelyn; Kornspun, Alana R.; Pignatelli, Marco; Kashtelyan, Vadim; Krashes, Michael J.; Lowell, Brad B.; Carlezon, William A.; Bonci, Antonello

    2018-01-01

    Endogenous dynorphin signaling via the kappa-opioid receptor (KOR) in the nucleus accumbens (NAcc) powerfully mediates negative affective states and stress reactivity. Excitatory inputs from the hippocampus and amygdala play a fundamental role in shaping the activity of both NAcc D1 and D2 MSNs, which encode positive and negative motivational valences, respectively. However, a circuit-based mechanism by which KOR modulation of excitation-inhibition balance modifies D1 and D2 MSN activity is lacking. Here, we provide a comprehensive synaptic framework wherein presynaptic KOR inhibition decreases excitatory drive of D1 MSN activity by the amygdala, but not hippocampus. Conversely, presynaptic inhibition by KORs of inhibitory synapses on D2 MSNs enhances integration of excitatory drive by the amygdala and hippocampus. In conclusion, we describe a circuit-based mechanism showing differential gating of afferent control of D1 and D2 MSN activity by KORs in a pathway specific manner. PMID:28056342

  3. A phylogenetic framework for root lesion nematodes of the genus Pratylenchus (Nematoda): Evidence from 18S and D2-D3 expansion segments of 28S ribosomal RNA genes and morphological characters.

    Science.gov (United States)

    Subbotin, Sergei A; Ragsdale, Erik J; Mullens, Teresa; Roberts, Philip A; Mundo-Ocampo, Manuel; Baldwin, James G

    2008-08-01

    The root lesion nematodes of the genus Pratylenchus Filipjev, 1936 are migratory endoparasites of plant roots, considered among the most widespread and important nematode parasites in a variety of crops. We obtained gene sequences from the D2 and D3 expansion segments of 28S rRNA partial and 18S rRNA from 31 populations belonging to 11 valid and two unidentified species of root lesion nematodes and five outgroup taxa. These datasets were analyzed using maximum parsimony and Bayesian inference. The alignments were generated using the secondary structure models for these molecules and analyzed with Bayesian inference under the standard models and the complex model, considering helices under the doublet model and loops and bulges under the general time reversible model. The phylogenetic informativeness of morphological characters is tested by reconstruction of their histories on rRNA based trees using parallel parsimony and Bayesian approaches. Phylogenetic and sequence analyses of the 28S D2-D3 dataset with 145 accessions for 28 species and 18S dataset with 68 accessions for 15 species confirmed among large numbers of geographical diverse isolates that most classical morphospecies are monophyletic. Phylogenetic analyses revealed at least six distinct major clades of examined Pratylenchus species and these clades are generally congruent with those defined by characters derived from lip patterns, numbers of lip annules, and spermatheca shape. Morphological results suggest the need for sophisticated character discovery and analysis for morphology based phylogenetics in nematodes.

  4. Anchoring Vignettes in EQ-5D-5L Questionnaire: Validation of a New Instrument.

    Science.gov (United States)

    Azzolina, Danila; Minto, Clara; Boschetto, Stefania; Martinato, Matteo; Bauce, Barbara; Iliceto, Sabino; Gregori, Dario

    2017-01-01

    Health Related Quality of Life (HRQoL) is an indicator of patient's physical, psychological and social life. HRQoL is influenced by experience, beliefs, perceptions and expectations, and measures subjective perspective of the patient himself. EQ-5D-5L and SF-12 questionnaires are validated instruments useful to measure HRQoL, increasingly administered in electronic formats. The main purpose is to evaluate the feasibility of anchoring vignettes for the EQ-5D-5L questionnaire, with the aim to improve intergroup comparability of responses among different subjects. A comparison with SF-12 questionnaire is carried out. This is a cross-sectional study conducted at the ambulatories of cardiology of the University Hospital of Padova, in Italy. Thirty-eight subjects with a diagnosis of cardiovascular disease or at risk of cardiovascular disease were enrolled. A factorial analysis has been performed to assess the convergent validity of EQ-5D-5L questionnaire compared to Sf-12. Moreover, a compound Hierarchical Ordered Probit (Chopit) model has been estimated to evaluate if the questionnaire form affects the subjective evaluation process in order to compare EQ-5D-5L with and without vignettes. Correlation and factor analysis demonstrate that EQ_5D questionnaire is coherent with SF-12 in paper format. Chopit model estimation shows that questionnaire format does not affect the subjective question interpretation. Moreover, in a parametric model including vignettes, education attainment, disease severity, and gender are predictors of HRQoL status. The EQ-5D including vignettes in electronic format seems to be a valid tool to measure HRQoL as compared to EQ-5D without vignettes in paper format and to SF-12 questionnaire.

  5. Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

    Science.gov (United States)

    Zhang, Guobin; Sun, Qiyuan; Jiang, Shan; Yang, Zhiyong; Ma, Xiaodong; Jiang, Haisong

    2017-11-01

    Postimplant validation is an indispensable part in the brachytherapy technique. It provides the necessary feedback to ensure the quality of operation. The ability to pick implanted seed relates directly to the accuracy of validation. To address it, an automatic approach is proposed for picking implanted brachytherapy seeds in 3D CT images. In order to pick seed configuration (location and orientation) efficiently, the approach starts with the segmentation of seed from CT images using a thresholding filter which based on gray-level histogram. Through the process of filtering and denoising, the touching seed and single seed are classified. The true novelty of this approach is found in the application of the canny edge detection and improved concave points matching algorithm to separate touching seeds. Through the computation of image moments, the seed configuration can be determined efficiently. Finally, two different experiments are designed to verify the performance of the proposed approach: (1) physical phantom with 60 model seeds, and (2) patient data with 16 cases. Through assessment of validated results by a medical physicist, the proposed method exhibited promising results. Experiment on phantom demonstrates that the error of seed location and orientation is within ([Formula: see text]) mm and ([Formula: see text])[Formula: see text], respectively. In addition, the most seed location and orientation error is controlled within 0.8 mm and 3.5[Formula: see text] in all cases, respectively. The average process time of seed picking is 8.7 s per 100 seeds. In this paper, an automatic, efficient and robust approach, performed on CT images, is proposed to determine the implanted seed location as well as orientation in a 3D workspace. Through the experiments with phantom and patient data, this approach also successfully exhibits good performance.

  6. Least Square NUFFT Methods Applied to 2D and 3D Radially Encoded MR Image Reconstruction

    Science.gov (United States)

    Song, Jiayu; Liu, Qing H.; Gewalt, Sally L.; Cofer, Gary; Johnson, G. Allan

    2009-01-01

    Radially encoded MR imaging (MRI) has gained increasing attention in applications such as hyperpolarized gas imaging, contrast-enhanced MR angiography, and dynamic imaging, due to its motion insensitivity and improved artifact properties. However, since the technique collects k-space samples nonuniformly, multidimensional (especially 3D) radially sampled MRI image reconstruction is challenging. The balance between reconstruction accuracy and speed becomes critical when a large data set is processed. Kaiser-Bessel gridding reconstruction has been widely used for non-Cartesian reconstruction. The objective of this work is to provide an alternative reconstruction option in high dimensions with on-the-fly kernels calculation. The work develops general multi-dimensional least square nonuniform fast Fourier transform (LS-NUFFT) algorithms and incorporates them into a k-space simulation and image reconstruction framework. The method is then applied to reconstruct the radially encoded k-space, although the method addresses general nonuniformity and is applicable to any non-Cartesian patterns. Performance assessments are made by comparing the LS-NUFFT based method with the conventional Kaiser-Bessel gridding method for 2D and 3D radially encoded computer simulated phantoms and physically scanned phantoms. The results show that the LS-NUFFT reconstruction method has better accuracy-speed efficiency than the Kaiser-Bessel gridding method when the kernel weights are calculated on the fly. The accuracy of the LS-NUFFT method depends on the choice of scaling factor, and it is found that for a particular conventional kernel function, using its corresponding deapodization function as scaling factor and utilizing it into the LS-NUFFT framework has the potential to improve accuracy. When a cosine scaling factor is used, in particular, the LS-NUFFT method is faster than Kaiser-Bessel gridding method because of a quasi closed-form solution. The method is successfully applied to 2D and

  7. Zend Framework 2 application development

    CERN Document Server

    Valles, Christopher

    2013-01-01

    The book is really pragmatic, focusing on the key aspects you usually need to create an application. We skip the boring theory and jump straight to the action. Also, the examples don't try to be perfect, they just show the topic in question or the tool/components we are using. Here the focus is on the framework itself not on how to architect applications. The book will spend a lot of time reviewing the examples and each chapter is created around the example used to explain the topics so the example is first, then the explanation.This book is great for you if you are new to Zend Framework 2 and

  8. Metal-Organic Frameworks with d-f Cyanide Bridges: Structural Diversity, Bonding Regime, and Magnetism

    NARCIS (Netherlands)

    Ferbinteanu, M.; Cimpoesu, F.; Tanase, S.; Cheng, P.

    2015-01-01

    We present a selection of metal-organic frameworks based on d-f and f-f linkages, discussing their structural features and properties from experimental and theoretical viewpoints. We give an overview of our own synthetic and modeling methodologies, highlighting the complexity of the

  9. Numerically robust and efficient nonlocal electron transport in 2D DRACO simulations

    Science.gov (United States)

    Cao, Duc; Chenhall, Jeff; Moses, Greg; Delettrez, Jacques; Collins, Tim

    2013-10-01

    An improved implicit algorithm based on Schurtz, Nicolai and Busquet (SNB) algorithm for nonlocal electron transport is presented. Validation with direct drive shock timing experiments and verification with the Goncharov nonlocal model in 1D LILAC simulations demonstrate the viability of this efficient algorithm for producing 2D lagrangian radiation hydrodynamics direct drive simulations. Additionally, simulations provide strong incentive to further modify key parameters within the SNB theory, namely the ``mean free path.'' An example 2D polar drive simulation to study 2D effects of the nonlocal flux as well as mean free path modifications will also be presented. This research was supported by the University of Rochester Laboratory for Laser Energetics.

  10. GPM GROUND VALIDATION DUAL-FREQUENCY DUAL-POLARIZED DOPPLER RADAR (D3R) IFLOODS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Dual-frequency Dual-polarized Doppler Radar (D3R) IFloodS data set contain radar reflectivity and doppler velocity measurements. The D3R...

  11. Insight into the local magnetic environments and deuteron mobility in jarosite (AFe3(SO4)2(OD)6, A = K, Na, D3O) and hydronium alunite ((D3O)Al3(SO4)2(OD,OD2)6), from variable temperature 2H MAS NMR spectroscopy

    DEFF Research Database (Denmark)

    Nielsen, Ulla Gro; Heinmaa, Ivo; Samoson, Ago

    2011-01-01

    to the different temperature dependence of their isotropic shifts. An activation energy of 6.3(4) kJ/mol is determined for the D3O+ motion in the isostructural compound D3OAl3(SO4)2(OD)6. Our NMR results support theories that ascribes the spin glass behavior of (H3O)Fe3(SO4)2(OD)6 is to disorder of the D3O+ ion...... and/or a less distorted Fe coordination environment. No sign of proton transfer reactions from the D3O+ ion to the framework is observed....

  12. Field-scale multi-phase LNAPL remediation: Validating a new computational framework against sequential field pilot trials.

    Science.gov (United States)

    Sookhak Lari, Kaveh; Johnston, Colin D; Rayner, John L; Davis, Greg B

    2018-03-05

    Remediation of subsurface systems, including groundwater, soil and soil gas, contaminated with light non-aqueous phase liquids (LNAPLs) is challenging. Field-scale pilot trials of multi-phase remediation were undertaken at a site to determine the effectiveness of recovery options. Sequential LNAPL skimming and vacuum-enhanced skimming, with and without water table drawdown were trialled over 78days; in total extracting over 5m 3 of LNAPL. For the first time, a multi-component simulation framework (including the multi-phase multi-component code TMVOC-MP and processing codes) was developed and applied to simulate the broad range of multi-phase remediation and recovery methods used in the field trials. This framework was validated against the sequential pilot trials by comparing predicted and measured LNAPL mass removal rates and compositional changes. The framework was tested on both a Cray supercomputer and a cluster. Simulations mimicked trends in LNAPL recovery rates (from 0.14 to 3mL/s) across all remediation techniques each operating over periods of 4-14days over the 78day trial. The code also approximated order of magnitude compositional changes of hazardous chemical concentrations in extracted gas during vacuum-enhanced recovery. The verified framework enables longer term prediction of the effectiveness of remediation approaches allowing better determination of remediation endpoints and long-term risks. Copyright © 2017 Commonwealth Scientific and Industrial Research Organisation. Published by Elsevier B.V. All rights reserved.

  13. When is a randomised controlled trial health equity relevant? Development and validation of a conceptual framework.

    Science.gov (United States)

    Jull, J; Whitehead, M; Petticrew, M; Kristjansson, E; Gough, D; Petkovic, J; Volmink, J; Weijer, C; Taljaard, M; Edwards, S; Mbuagbaw, L; Cookson, R; McGowan, J; Lyddiatt, A; Boyer, Y; Cuervo, L G; Armstrong, R; White, H; Yoganathan, M; Pantoja, T; Shea, B; Pottie, K; Norheim, O; Baird, S; Robberstad, B; Sommerfelt, H; Asada, Y; Wells, G; Tugwell, P; Welch, V

    2017-09-25

    Randomised controlled trials can provide evidence relevant to assessing the equity impact of an intervention, but such information is often poorly reported. We describe a conceptual framework to identify health equity-relevant randomised trials with the aim of improving the design and reporting of such trials. An interdisciplinary and international research team engaged in an iterative consensus building process to develop and refine the conceptual framework via face-to-face meetings, teleconferences and email correspondence, including findings from a validation exercise whereby two independent reviewers used the emerging framework to classify a sample of randomised trials. A randomised trial can usefully be classified as 'health equity relevant' if it assesses the effects of an intervention on the health or its determinants of either individuals or a population who experience ill health due to disadvantage defined across one or more social determinants of health. Health equity-relevant randomised trials can either exclusively focus on a single population or collect data potentially useful for assessing differential effects of the intervention across multiple populations experiencing different levels or types of social disadvantage. Trials that are not classified as 'health equity relevant' may nevertheless provide information that is indirectly relevant to assessing equity impact, including information about individual level variation unrelated to social disadvantage and potentially useful in secondary modelling studies. The conceptual framework may be used to design and report randomised trials. The framework could also be used for other study designs to contribute to the evidence base for improved health equity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Validation of Friction Models in MARS-MultiD Module with Two-Phase Cross Flow Experiment

    International Nuclear Information System (INIS)

    Choi, Chi-Jin; Yang, Jin-Hwa; Cho, Hyoung-Kyu; Park, Goon-Cher; Euh, Dong-Jin

    2015-01-01

    In the downcomer of Advanced Power Reactor 1400 (APR1400) which has direct vessel injection (DVI) lines as an emergency core cooling system, multidimensional two-phase flow may occur due to the Loss-of-Coolant-Accident (LOCA). The accurate prediction about that is high relevance to evaluation of the integrity of the reactor core. For this reason, Yang performed an experiment that was to investigate the two-dimensional film flow which simulated the two-phase cross flow in the upper downcomer, and obtained the local liquid film velocity and thickness data. From these data, it could be possible to validate the multidimensional modules of system analysis codes. In this study, MARS-MultiD was used to simulate the Yang's experiment, and obtained the local variables. Then, the friction models used in MARS-MultiD were validated by comparing the two-phase flow experimental results with the calculated local variables. In this study, the two-phase cross flow experiment was modeled by the MARS-MultiD. Compared with the experimental results, the calculated results by the code properly presented mass conservation which could be known from the relation between the liquid film velocity and thickness at the same flow rate. The magnitude and direction of the liquid film, however, did not follow well with experimental results. According to the results of Case-2, wall friction should be increased, and interfacial friction should be decreased in MARS-MultiD. These results show that it is needed to modify the friction models in the MARS-MultiD to simulate the two-phase cross flow

  15. IM-16: A new microporous germanosilicate with a novel framework topology containing d4r and mtw composite building units

    International Nuclear Information System (INIS)

    Lorgouilloux, Yannick; Dodin, Mathias; Paillaud, Jean-Louis; Caullet, Philippe; Michelin, Laure; Josien, Ludovic; Ersen, Ovidiu; Bats, Nicolas

    2009-01-01

    The synthesis and the structure of IM-16 a new germanosilicate with a novel zeolitic topology prepared hydrothermally with the ionic liquid 3-ethyl-1-methyl-3H-imidazol-1-ium as the organic structure-directing agent are reported. The structure of calcined and partially rehydrated IM-16 of chemical formula |(H 2 O) 0.16 |[Si 3.47 Ge 2.53 O 12 ] was solved from powder XRD data in space group Cmcm with a=15.0861(2) A, b=17.7719(3) A, c=19.9764(3) A, V=5355.84(12) A 3 (Z=16). This new zeolite framework type contains 10-MRs channels and may be described from the d4r and mtw composite building units. - Graphical abstract: The synthesis and the structure of IM-16 a new germanosilicate with a novel zeolitic topology prepared hydrothermally with the ionic liquid 3-ethyl-1-methyl-3H-imidazol-1-ium as the organic structure-directing agent are reported. This new zeolite framework type contains 10-MRs channels and may be described from the d4r and mtw composite building units

  16. Crystal Structure and Antiferromagnetic Ordering of Quasi-2D [Cu(HF2)(pyz)2]TaF6 (pyz=pyrazine)

    Science.gov (United States)

    Manson, J. L.; Schlueter, J. A.; McDonald, R. D.; Singleton, J.

    2010-04-01

    The crystal structure of the title compound was determined by X-ray diffraction at 90 and 295 K. Copper(II) ions are coordinated to four bridging pyz ligands to form square layers in the ab-plane. Bridging HF2- ligands join the layers together along the c-axis to afford a tetragonal, three-dimensional (3D) framework that contains TaF6- anions in every cavity. At 295 K, the pyz rings lie exactly perpendicular to the layers and cooling to 90 K induces a canting of those rings. Magnetically, the compound exhibits 2D antiferromagnetic correlations within the 2D layers with an exchange interaction of -13.1(1) K. Weak interlayer interactions, as mediated by Cu-F-H-F-Cu, leads to long-range magnetic order below 4.2 K. Pulsed-field magnetization data at 0.5 K show a concave curvature with increasing B and reveal a saturation magnetization at 35.4 T.

  17. Insight into the structural requirement of substituted quinazolinone biphenyl acylsulfonamides derivatives as Angiotensin II AT1 receptor antagonist: 2D and 3D QSAR approach

    Directory of Open Access Journals (Sweden)

    Mukesh C. Sharma

    2014-01-01

    Full Text Available A series of 19 molecules substituted quinazolinone biphenyl acylsulfonamides derivatives displaying variable inhibition of Angiotensin II receptor AT1 activity were selected to develop models for establishing 2D and 3D QSAR. The compounds in the selected series were characterized by spatial, molecular and electro topological descriptors using QSAR module of Molecular Design Suite (VLife MDS™ 3.5. The best 2D QSAR model was selected, having correlation coefficient r2 (0.8056 and cross validated squared correlation coefficient q2 (0.6742 with external predictive ability of pred_r2 0.7583 coefficient of correlation of predicted data set (pred_r2se 0.2165. The results obtained from QSAR studies could be used in designing better Ang II activity among the congeners in future. The optimum QSAR model showed that the parameters SsssCHE index, SddCE-index, T_2_Cl_4, and SssNHE-index contributed in the model. 3D QSAR analysis by kNN-molecular field analysis approach developed based on principles of the k-nearest neighbor method combined with Genetic algorithms, stepwise forward variable selection approach; a leave-one-out cross-validated correlation coefficient (q2 of 0.6516 and a non-cross-validated correlation coefficient (r2 of 0.8316 and pred_r2 0.6954 were obtained. Contour maps using this approach showed that steric, electrostatic, and hydrophobic field effects dominantly determine binding affinities. The information rendered by 3D QSAR models may lead to a better understanding of structural requirements of Angiotensin II receptor and can help in the design of novel potent antihypertensive molecules.

  18. 2D vs. 3D imaging in laparoscopic surgery-results of a prospective randomized trial.

    Science.gov (United States)

    Buia, Alexander; Stockhausen, Florian; Filmann, Natalie; Hanisch, Ernst

    2017-12-01

    3D imaging is an upcoming technology in laparoscopic surgery, and recent studies have shown that the modern 3D technique is superior in an experimental setting. However, the first randomized controlled clinical trial in this context dates back to 1998 and showed no significant difference between 2D and 3D visualization using the first 3D generation technique, which is now more than 15 years old. Positive results measured in an experimental setting considering 3D imaging on surgical performance led us to initiate a randomized controlled pragmatic clinical trial to validate our findings in daily clinical routine. Standard laparoscopic operations (cholecystectomy, appendectomy) were preoperatively randomized to a 2D or 3D imaging system. We used a surgical comfort scale (Likert scale) and the Raw NASA Workload TLX for the subjective assessment of 2D and 3D imaging; the duration of surgery was also measured. The results of 3D imaging were statistically significant better than 2D imaging concerning the parameters "own felt safety" and "task efficiency"; the difficulty level of the procedures in the 2D and 3D groups did not differ. Overall, the Raw NASA Workload TLX showed no significance between the groups. 3D imaging could be a possible advantage in laparoscopic surgery. The results of our clinical trial show increased personal felt safety and efficiency of the surgeon using a 3D imaging system. Overall of the procedures, the findings assessed using Likert scales in terms of own felt safety and task efficiency were statistically significant for 3D imaging. The individually perceived workload assessed with the Raw NASA TLX shows no difference. Although these findings are subjective impressions of the performing surgeons without a clear benefit for 3D technology in clinical outcome, we think that these results show the capability that 3D laparoscopy can have a positive impact while performing laparoscopic procedures.

  19. Generation and validation of the WIMS-D5 library based on JENDL-3.2

    International Nuclear Information System (INIS)

    Gil, Choong-Sup; Kim, Jung-Do

    2002-01-01

    A WIMS-D5 library based on JENDL-3.2 has been prepared and is being tested against benchmark problems. Several sensitivity calculations for stability confirmation of the library were carried out, such as fission spectrum dependency and the self-shielding effects of the elastic scattering cross sections and the self-shielding effects 240 Pu and 242 Pu capture cross sections below 4.0 eV. The results of benchmark calculations with the libraries based on JENDL-3.2, ENDF/B-VI.5, JEF-2.2, and the 1986 WIMS-D library were intercompared. The multiplication factors for the thermal lattices are slightly underpredicted by all libraries (up to 1% with ENDF/B-VI.5). The k eff values with the library based on JENDL-3.2 are slightly higher than those of ENDF/B-VI.5 and JEF-2.2. The spectral indices for the lattices with JENDL-3.2 agree with the measured quantities within the uncertainties of the experiments. The calculated amounts of some isotopes such as 149 Sm, 237 Np, 238 Pu, 242 Cm and 243 Cm show large differences from the measured or reference values. (author)

  20. Validation of quantitative brain dopamine D2 receptor imaging with a conventional single-head SPET camera

    International Nuclear Information System (INIS)

    Nikkinen, P.; Liewendahl, K.; Savolainen, S.; Launes, J.

    1993-01-01

    Phantom measurements were performed with a conventional single-head single-photon emission tomography (SPET) camera in order to validate the relevance of the basal ganglia/frontal cortex iodine-123 iodobenzamide (IBZM) uptake ratios measured in patients. Inside a cylindrical phantom (diameter 22 cm), two cylinders with a diameter of 3.3 cm were inserted. The activity concentrations of the cylinders ranged from 6.0 to 22.6 kBq/ml and the cylinder/background activity ratios varied from 1.4 to 3.8. From reconstructed SPET images the cylinder/background activity ratios were calculated using three different regions of interest (ROIs). A linear relationship between the measured activity ratio and the true activity ratio was obtained. In patient studies, basal ganglia/frontal cortex IBZM uptake ratios determined from the reconstructed slices using attentuation correction prior to reconstruction were 1.30 ±0.03 in idiopathic Parkinson's disease (n = 9), 1,33 ±0.09 in infantile and juvenile neuronal ceroid lipofuscinosis (n = 7) and 1.34 ±0.05 in narcolepsy (n = 8). Patients with Huntington's disease had significantly lower ratios (1.09 ±0.04, n = 5). The corrected basal ganglia/frontal cortex ratios, determined using linear regression, were about 80 % higher. The use of dual-window scatter correction increased the measured ratios by about 10 %. Although comprehensive correction methods can further improve the resolution in SPET images, the resolution of the SPET system used by us (1.5 - 2 cm) will determine what is achievable in basal ganglia D2 receptor imaging. (orig.)

  1. Validation of quantitative brain dopamine D2 receptor imaging with a conventional single-head SPET camera

    Energy Technology Data Exchange (ETDEWEB)

    Nikkinen, P [Helsinki Univ. (Finland). Dept. of Clinical Chemistry; Liewendahl, K [Helsinki Univ. (Finland). Dept. of Clinical Chemistry; Savolainen, S [Helsinki Univ. (Finland). Dept. of Physics; Launes, J [Helsinki Univ. (Finland). Dept. of Neurology

    1993-08-01

    Phantom measurements were performed with a conventional single-head single-photon emission tomography (SPET) camera in order to validate the relevance of the basal ganglia/frontal cortex iodine-123 iodobenzamide (IBZM) uptake ratios measured in patients. Inside a cylindrical phantom (diameter 22 cm), two cylinders with a diameter of 3.3 cm were inserted. The activity concentrations of the cylinders ranged from 6.0 to 22.6 kBq/ml and the cylinder/background activity ratios varied from 1.4 to 3.8. From reconstructed SPET images the cylinder/background activity ratios were calculated using three different regions of interest (ROIs). A linear relationship between the measured activity ratio and the true activity ratio was obtained. In patient studies, basal ganglia/frontal cortex IBZM uptake ratios determined from the reconstructed slices using attentuation correction prior to reconstruction were 1.30 [+-]0.03 in idiopathic Parkinson's disease (n = 9), 1,33 [+-]0.09 in infantile and juvenile neuronal ceroid lipofuscinosis (n = 7) and 1.34 [+-]0.05 in narcolepsy (n = 8). Patients with Huntington's disease had significantly lower ratios (1.09 [+-]0.04, n = 5). The corrected basal ganglia/frontal cortex ratios, determined using linear regression, were about 80 % higher. The use of dual-window scatter correction increased the measured ratios by about 10 %. Although comprehensive correction methods can further improve the resolution in SPET images, the resolution of the SPET system used by us (1.5 - 2 cm) will determine what is achievable in basal ganglia D2 receptor imaging. (orig.)

  2. Flexible metal-organic framework compounds: In situ studies for selective CO{sub 2} capture

    Energy Technology Data Exchange (ETDEWEB)

    Allen, A.J., E-mail: andrew.allen@nist.gov [Material Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899-8520 (United States); Espinal, L.; Wong-Ng, W. [Material Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899-8520 (United States); Queen, W.L. [NIST Center for Neutron Research, Gaithersburg, MD 20899-6102 (United States); The Molecular Foundry, Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA 94720 (United States); Brown, C.M. [NIST Center for Neutron Research, Gaithersburg, MD 20899-6102 (United States); Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716 (United States); Kline, S.R. [NIST Center for Neutron Research, Gaithersburg, MD 20899-6102 (United States); Kauffman, K.L. [National Energy Technology Laboratory (NETL), US Department of Energy, Pittsburgh, PA 15236 (United States); Culp, J.T. [National Energy Technology Laboratory (NETL), US Department of Energy, Pittsburgh, PA 15236 (United States); URS Corporation, South Park, PA 15219 (United States); Matranga, C. [National Energy Technology Laboratory (NETL), US Department of Energy, Pittsburgh, PA 15236 (United States)

    2015-10-25

    Results are presented that explore the dynamic structural changes occurring in two highly flexible nanocrystalline metal-organic framework (MOF) compounds during the adsorption and desorption of pure gases and binary mixtures. The Ni(1,2-bis(4-pyridyl)ethylene)[Ni(CN){sub 4}] and catena-bis(dibenzoylmethanato)-(4,4′-bipyridyl)nickel(II) chosen for this study are 3-D and 1-D porous coordination polymers (PCP) with a similar gate opening pressure response for CO{sub 2} isotherms at 303 K, but with differing degrees of flexibility for structural change to accommodate guest molecules. As such, they serve as a potential model system for evaluating the complex kinetics associated with dynamic structure changes occurring in response to gas adsorption in flexible MOF systems. Insights into the crystallographic changes occurring as the MOF pore structure expands and contracts in response to interactions with CO{sub 2}, N{sub 2}, and CO{sub 2}/N{sub 2} mixtures have been obtained from in situ small-angle neutron scattering and neutron diffraction, combined with ex situ X-ray diffraction structure measurements. The role of structure in carbon capture functionality is discussed with reference to the ongoing characterization challenges and a possible materials-by-design approach. - Graphical abstract: We present in situ small-angle neutron scattering results for two flexible metal-organic frameworks (MOFs). The figure shows that for one (NiBpene, high CO{sub 2} adsorption) the intensity of the Bragg peak for the expandable d-spacing most associated with CO{sub 2} adsorption varies approximately with the isotherm, while for the other (NiDBM-Bpy, high CO{sub 2} selectivity) the d-spacing, itself, varies with the isotherm. The cartoons show the proposed modes of structural change. - Highlights: • Dynamic structures of two flexible MOF CO{sub 2} sorbent compounds are compared in situ. • These porous solid sorbents serve as models for pure & dual gas adsorption. • Different

  3. From 2D to 3D turbulence through 2D3C configurations

    Science.gov (United States)

    Buzzicotti, Michele; Biferale, Luca; Linkmann, Moritz

    2017-11-01

    We study analytically and numerically the geometry of the nonlinear interactions and the resulting energy transfer directions of 2D3C flows. Through a set of suitably designed Direct Numerical Simulations we also study the coupling between several 2D3C flows, where we explore the transition between 2D and fully 3D turbulence. In particular, we find that the coupling of three 2D3C flows on mutually orthogonal planes subject to small-scale forcing leads to a stationary 3D out-of-equilibrium dynamics at the energy containing scales where the inverse cascade is directly balanced by a forward cascade carried by a different subsets of interactions. ERC AdG Grant No 339032 NewTURB.

  4. 2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) for postchemotherapy seminoma residual lesions

    DEFF Research Database (Denmark)

    Bachner, M; Loriot, Y; Gross-Goupil, M

    2012-01-01

    2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) has been recommended in international guidelines in the evaluation of postchemotherapy seminoma residuals. Our trial was designed to validate these recommendations in a larger group of patients.......2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) has been recommended in international guidelines in the evaluation of postchemotherapy seminoma residuals. Our trial was designed to validate these recommendations in a larger group of patients....

  5. Over 100 Validated and Candidate Planets Orbiting Bright Stars in K2 Campaigns 0-10

    Science.gov (United States)

    Mayo, Andrew; Vanderburg, Andrew; Latham, David; Bieryla, Allyson; Morton, Timothy

    2018-01-01

    Since 2014, NASA's K2 mission has observed large portions of the ecliptic plane in search of transiting planets and has detected hundreds of planet candidates. With observations planned until at least early 2018, K2 will continue to identify more planet candidates. We present here over 250 planet candidates observed during Campaigns 0-10 of the K2 mission that are orbiting stars brighter than 13th magnitude and for which we have obtained high-resolution spectra. We analyze these candidates using the VESPA package in order to calculate the false positive probability (FPP), and find that more than half are validated with a FPP less than 0.1%. We show that like the population of planets found during the original Kepler mission, large planets discovered by K2 tend to orbit metal-rich stars. We also show tentative evidence of a gap in the planet radius distribution. We compare our sample to the Kepler candidate sample investigated by Fulton and collaborators and conclude that more planets are required to confirm the gap. This work, in addition to increasing the population of validated K2 planets and providing new targets for follow-up observations, will also serve as a framework for validating candidates from upcoming K2 campaigns and the Transiting Exoplanet Survey Satellite (TESS), expected to launch in 2018.

  6. Validating (d,p gamma) as a Surrogate for Neutron Capture

    Energy Technology Data Exchange (ETDEWEB)

    Ratkiewicz, A. [Rutgers University; Cizewski, J. A. [Rutgers University; Pain, S. [Oak Ridge National Laboratory (ORNL); Adekola, A. S. [Rutgers University; Burke, J. T. [Lawrence Livermore National Laboratory (LLNL); Casperson, R.J. [Lawrence Livermore National Laboratory (LLNL); Fotiades, N. [Los Alamos National Laboratory (LANL); McCleskey, M. [Texas A& M University; Burcher, S. [Rutgers University; Shand, C. M. [Rutgers Univ./Univ. of Surrey, UK; Austin, R. A. E. [Saint Mary’s University, Halifa, Canada; Baugher, T. [Rutgers University; Carpenter, M. P. [Argonne National Laboratory (ANL); Devlin, M. [Los Alamos National Laboratory (LANL); Escher, J. E. [Lawrence Livermore National Laboratory (LLNL); Hardy, S. [Rutgers Univ./Univ. of Surrey, UK; Hatarik, R. [Lawrence Livermore National Laboratory (LLNL); Howard, M. [Rutgers University; Hughes, R. [University of Richmond, VA; Jones, K. L. [University of Tennessee, Knoxville (UTK); Kozub, R. L. [Tennessee Technological University (TTU); Lister, C. J. [University of Massachusetts, Lowell; Manning, B. [Rutgers University; O' Donnell, J. M. [Los Alamos National Laboratory (LANL); Peters, W. A. [Oak Ridge Associated Universities (ORAU); Ross, T.J. [University of Richmond, VA; Scielzo, N.D. [Lawrence Livermore National Laboratory (LLNL); Seweryniak, D. [Argonne National Laboratory (ANL); Zhu, S. [Argonne National Laboratory (ANL)

    2015-01-01

    The r-process is responsible for creating roughly half of the elements heavier than iron. It has recently become understood that the rates at which neutron capture reactions proceed at late times in the rprocess may dramatically affect the final abundance pattern. However, direct measurements of neutron capture reaction rates on exotic nuclei are exceptionally difficult, necessitating the development of indirect approaches such as the surrogate technique. The (d,py) reaction at low energies was identified as a promising surrogate for the (n,y) reaction, as both reactions share many characteristics. We report on a program to validate (d,py) as a surrogate for (n,y) using 95Mo as a target. The experimental campaign includes direct measurements of the y-ray intensities from the decay of excited states populated in the 95Mo(n,y) and 95Mo(d,py) reactions.

  7. Development and validation of an UFLC-MS/MS method for enantioselectivity determination of d,l-thero-methylphenidate, d,l-thero-ethylphenidate and d,l-thero-ritalinic acid in rat plasma and its application to pharmacokinetic study.

    Science.gov (United States)

    Zhang, Chenghao; Luo, Huafei; Wu, Yubo; Zhang, Junyun; Zhang, Furong; Lin, Guobei; Wang, Hao

    2016-02-01

    A chiral UFLC-MS/MS method was established and validated for quantifying d-threo-methylphenidate (d-threo-MPH), l-threo-methylphenidate (l-threo-MPH), d-threo-ethylphenidate (d-threo-EPH), l-threo-ethylphenidate (l-threo-EPH) and d,l-threo-ritalinic acid (d,l-threo-RA) in rat plasma over the linearity range of 1-500ng/mL. Chiral separation was performed on an Astec Chirobiotic V2 column (5μm, 250×2.1mm) with isocratic elution using methanol containing 0.003% ammonium acetate (w/v) and 0.003% trifluoroacetic acid (v/v) at a flow of 0.3mL/min. All analytes and IS were extracted from rat plasma by a one-step liquid-liquid extraction (LLE) method. The intra- and inter-run accuracies were within 85-115%, and the intra- and inter-run precision were <10% for all analytes. Extraction recoveries were 55-62% for d-threo-MPH, 54-60% for l-threo-MPH, 55-60% for d-threo-EPH, 53-57% for l-threo-EPH and 25-30% for d,l-threo-RA. The validated UFLC-MS/MS method successfully applied to the pharmacokinetic interaction study of oral d-threo-MPH and l-threo-MPH (alone or in combination) in female Sprague Dawley rats. The EPH was not detected in rat plasma following oral administrated MPH without EtOH. As far as it is known to the authors, this study is the first one step liquid-liquid extraction method to extract and UFLC-MS/MS method to quantify d-threo-MPH, l-threo-MPH, d-threo-EPH, l-threo-EPH and d,l-threo-RA simultaneously. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Validation of the Dutch Questionnaire on Emotional Labor (D-QEL) in Nurses and Teachers

    NARCIS (Netherlands)

    Näring, Gérard; Briët, Mariette; Brouwers, André

    2008-01-01

    This paper describes the validation of the Dutch Questionnaire on Emotional Labor (D-QEL) in a sample of 365 teachers and in a sample of 334 nurses. The D-QEL is a 13 item self-report questionnaire that measures surface acting, deep acting, suppression and emotional consonance. Confirmatory factor

  9. WE-AB-BRA-08: Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration

    International Nuclear Information System (INIS)

    Ouadah, S; Jacobson, M; Stayman, JW; Siewerdsen, JH; Ehtiati, T

    2016-01-01

    Purpose: Intraoperative C-arm cone-beam CT (CBCT) is subject to artifacts arising from patient motion during the fairly long (∼5–20 s) scan times. We present a fiducial free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in geometric calibration. Methods: A 3D-2D registration process was used to register each projection to DRRs computed from the 3D image by maximizing gradient orientation (GO) using the CMA-ES optimizer. The resulting rigid 6 DOF transforms were applied to the system projection matrices, and a 3D image was reconstructed via model-based image reconstruction (MBIR, which accommodates the resulting noncircular orbit). Experiments were conducted using a Zeego robotic C-arm (20 s, 200°, 496 projections) to image a head phantom undergoing various types of motion: 1) 5° lateral motion; 2) 15° lateral motion; and 3) 5° lateral motion with 10 mm periodic inferior-superior motion. Images were reconstructed using a penalized likelihood (PL) objective function, and structural similarity (SSIM) was measured for axial slices of the reconstructed images. A motion-free image was acquired using the same protocol for comparison. Results: There was significant improvement (p 0.99, indicating near identity to the motion-free reference. The point spread function (PSF) measured from a wire in the phantom was restored to that of the reference in each case. Conclusion: The 3D-2D registration method provides a robust framework for mitigation of motion artifacts and is expected to hold for applications in the head, pelvis, and extremities with reasonably constrained operative setup. Further improvement can be achieved by incorporating multiple rigid components and non-rigid deformation within the framework. The method is highly parallelizable and could in principle be run with every acquisition. Research supported by National Institutes of Health Grant No. R01-EB-017226 and academic

  10. Validation and comparison of EuroQoL-5 dimension (EQ-5D) and Short Form-6 dimension (SF-6D) among stable angina patients.

    Science.gov (United States)

    Wu, Jing; Han, Yuerong; Zhao, Fei-Li; Zhou, Jin; Chen, Zhijun; Sun, He

    2014-10-25

    Several preference-based health-related quality of life (HRQoL) instruments have been published and widely used in different populations. However no consensus has emerged regarding the most appropriate instrument in therapeutic area of stable angina. This study compared and validated the psychometric properties of two generic preference-based instruments, the EQ-5D and SF-6D, among Chinese stable angina patients. Convergent validity of the EQ-5D and SF-6D was examined with eight a priori hypotheses from stable angina patients in conjunction with Seattle Angina Questionnaire (SAQ). Responsiveness was compared using the effect size (ES), relative efficiency (RE) and receiver operating characteristic (ROC) curves. Agreement between the EQ-5D and SF-6D was tested using intra-class correlation coefficient (ICC) and Bland-Altman plot. Factors affecting utility difference were explored with multiple linear regression analysis. In 411 patients (mean age 68.08 ± 11.35), mean utility scores (SD) were 0.78 (0.15) for the EQ-5D and 0.68 (0.12) for the SF-6D. Validity was demonstrated by the moderate to strong correlation coefficients (Range: 0.368-0.594, Pstable-angina-specific health status than the EQ-5D (ES: 0.426 to 1.126). RE suggested that the SF-6D (RE: 44.8 to 177.8%) was more efficient than the EQ-5D except for physical function. Poor agreement between them was observed with ICC (0.448, Pstable angina patients. The SF-6D may be a more effective tool with lower ceiling effect and greater sensitivity. Further study is needed to compare other properties, such as reliability and longitudinal response.

  11. Partially Loaded Cavity Analysis by Using the 2-D FDTD Method

    International Nuclear Information System (INIS)

    Yao Bin; Zheng Qin-Hong; Peng Jin-Hui; Zhong Ru-Neng; Xiang Tai; Xu Wan-Song

    2011-01-01

    A compact two-dimensional (2-D) finite-difference time-domain (FDTD) method is proposed to calculate the resonant frequencies and quality factors of a partially loaded cavity that is uniform in the z-direction and has an arbitrary cross section in the x—y plane. With the description of z dependence by k z , the three-dimensional (3-D) problem can be transformed into a 2-D problem. Therefore, less memory and CPU time are required as compared to the conventional 3-D FDTD method. Three representative examples, a half-loaded rectangular cavity, an inhomogeneous cylindrical cavity and a cubic cavity loaded with dielectric post, are presented to validate the utility and efficiency of the proposed method. (cross-disciplinary physics and related areas of science and technology)

  12. Fusion of CT coronary angiography and whole-heart dynamic 3D cardiac MR perfusion: building a framework for comprehensive cardiac imaging.

    Science.gov (United States)

    von Spiczak, Jochen; Manka, Robert; Gotschy, Alexander; Oebel, Sabrina; Kozerke, Sebastian; Hamada, Sandra; Alkadhi, Hatem

    2018-04-01

    The purpose of this work was to develop a framework for 3D fusion of CT coronary angiography (CTCA) and whole-heart dynamic 3D cardiac magnetic resonance perfusion (3D-CMR-Perf) image data-correlating coronary artery stenoses to stress-induced myocardial perfusion deficits for the assessment of coronary artery disease (CAD). Twenty-three patients who underwent CTCA and 3D-CMR-Perf for various indications were included retrospectively. For CTCA, image quality and coronary diameter stenoses > 50% were documented. For 3D-CMR-Perf, image quality and stress-induced perfusion deficits were noted. A software framework was developed to allow for 3D image fusion of both datasets. Computation steps included: (1) fully automated segmentation of coronary arteries and heart contours from CT; (2) manual segmentation of the left ventricle in 3D-CMR-Perf images; (3) semi-automatic co-registration of CT/CMR datasets; (4) projection of the 3D-CMR-Perf values on the CT left ventricle. 3D fusion analysis was compared to separate inspection of CTCA and 3D-CMR-Perf data. CT and CMR scans resulted in an image quality being rated as good to excellent (mean scores 3.5 ± 0.5 and 3.7 ± 0.4, respectively, scale 1-4). 3D-fusion was feasible in all 23 patients, and perfusion deficits could be correlated to culprit coronary lesions in all but one case (22/23 = 96%). Compared to separate analysis of CT and CMR data, coronary supply territories of 3D-CMR-Perf perfusion deficits were refined in two cases (2/23 = 9%), and the relevance of stenoses in CTCA was re-judged in four cases (4/23 = 17%). In conclusion, 3D fusion of CTCA/3D-CMR-Perf facilitates anatomic correlation of coronary lesions and stress-induced myocardial perfusion deficits thereby helping to refine diagnostic assessment of CAD.

  13. Low band gap frequencies and multiplexing properties in 1D and 2D mass spring structures

    International Nuclear Information System (INIS)

    Aly, Arafa H; Mehaney, Ahmed

    2016-01-01

    This study reports on the propagation of elastic waves in 1D and 2D mass spring structures. An analytical and computation model is presented for the 1D and 2D mass spring systems with different examples. An enhancement in the band gap values was obtained by modeling the structures to obtain low frequency band gaps at small dimensions. Additionally, the evolution of the band gap as a function of mass value is discussed. Special attention is devoted to the local resonance property in frequency ranges within the gaps in the band structure for the corresponding infinite periodic lattice in the 1D and 2D mass spring system. A linear defect formed of a row of specific masses produces an elastic waveguide that transmits at the narrow pass band frequency. The frequency of the waveguides can be selected by adjusting the mass and stiffness coefficients of the materials constituting the waveguide. Moreover, we pay more attention to analyze the wave multiplexer and DE-multiplexer in the 2D mass spring system. We show that two of these tunable waveguides with alternating materials can be employed to filter and separate specific frequencies from a broad band input signal. The presented simulation data is validated through comparison with the published research, and can be extended in the development of resonators and MEMS verification. (paper)

  14. Projection-slice theorem based 2D-3D registration

    Science.gov (United States)

    van der Bom, M. J.; Pluim, J. P. W.; Homan, R.; Timmer, J.; Bartels, L. W.

    2007-03-01

    In X-ray guided procedures, the surgeon or interventionalist is dependent on his or her knowledge of the patient's specific anatomy and the projection images acquired during the procedure by a rotational X-ray source. Unfortunately, these X-ray projections fail to give information on the patient's anatomy in the dimension along the projection axis. It would be very profitable to provide the surgeon or interventionalist with a 3D insight of the patient's anatomy that is directly linked to the X-ray images acquired during the procedure. In this paper we present a new robust 2D-3D registration method based on the Projection-Slice Theorem. This theorem gives us a relation between the pre-operative 3D data set and the interventional projection images. Registration is performed by minimizing a translation invariant similarity measure that is applied to the Fourier transforms of the images. The method was tested by performing multiple exhaustive searches on phantom data of the Circle of Willis and on a post-mortem human skull. Validation was performed visually by comparing the test projections to the ones that corresponded to the minimal value of the similarity measure. The Projection-Slice Theorem Based method was shown to be very effective and robust, and provides capture ranges up to 62 degrees. Experiments have shown that the method is capable of retrieving similar results when translations are applied to the projection images.

  15. Activated sludge model No. 2d, ASM2d

    DEFF Research Database (Denmark)

    Henze, M.

    1999-01-01

    The Activated Sludge Model No. 2d (ASM2d) presents a model for biological phosphorus removal with simultaneous nitrification-denitrification in activated sludge systems. ASM2d is based on ASM2 and is expanded to include the denitrifying activity of the phosphorus accumulating organisms (PAOs......). This extension of ASM2 allows for improved modeling of the processes, especially with respect to the dynamics of nitrate and phosphate. (C) 1999 IAWQ Published by Elsevier Science Ltd. All rights reserved....

  16. Cross-Modality 2D-3D Face Recognition via Multiview Smooth Discriminant Analysis Based on ELM

    Directory of Open Access Journals (Sweden)

    Yi Jin

    2014-01-01

    Full Text Available In recent years, 3D face recognition has attracted increasing attention from worldwide researchers. Rather than homogeneous face data, more and more applications require flexible input face data nowadays. In this paper, we propose a new approach for cross-modality 2D-3D face recognition (FR, which is called Multiview Smooth Discriminant Analysis (MSDA based on Extreme Learning Machines (ELM. Adding the Laplacian penalty constrain for the multiview feature learning, the proposed MSDA is first proposed to extract the cross-modality 2D-3D face features. The MSDA aims at finding a multiview learning based common discriminative feature space and it can then fully utilize the underlying relationship of features from different views. To speed up the learning phase of the classifier, the recent popular algorithm named Extreme Learning Machine (ELM is adopted to train the single hidden layer feedforward neural networks (SLFNs. To evaluate the effectiveness of our proposed FR framework, experimental results on a benchmark face recognition dataset are presented. Simulations show that our new proposed method generally outperforms several recent approaches with a fast training speed.

  17. D.3.2 PLOT Persuasive Learning Design Framework

    DEFF Research Database (Denmark)

    Gram-Hansen, Sandra Burri; Schärfe, Henrik; Winther-Nielsen, Nicolai

    2011-01-01

    of the technological learning tools and products which are currently related to the PLOT project, namely the GLOMaker and the 3ET tool, and a selection of GLOs and learning exercises. The primary focus of the analysis is to explore how the theoretical perspectives presented in D.3.1 are represented in these tools...... as an: ‚Internal report for project use containing an empirically-based assessment of existing systems and their potential in terms of learning and persuasion. This will be used as a discussion document by the consortium.‛ To meet the requirements of this deliverable, this documents presents analysis......, in particular the notions of persuasive design and constructive alignment. Whilst the report provides a persuasive design perspective on the technologies related to Euro PLOT, it must be stressed that if the document is to function as a basis for further discussion within the consortium, the partners...

  18. Electrochemically active nanocomposites of Li4Ti5O12 2D nanosheets and SnO2 0D nanocrystals with improved electrode performance

    International Nuclear Information System (INIS)

    Han, Song Yi; Kim, In Young; Lee, Sang-Hyup; Hwang, Seong-Ju

    2012-01-01

    Electrochemically active nanocomposites consisting of Li 4 Ti 5 O 12 2D nanosheets and SnO 2 0D nanocrystals are synthesized by the crystal growth of tin dioxide on the surface of 2D nanostructured lithium titanate. According to powder X-ray diffraction and electron microscopic analyses, the rutile-structured SnO 2 nanocrystals are stabilized on the surface of spinel-structured Li 4 Ti 5 O 12 2D nanosheets. The homogeneous hybridization of tin dioxide with lithium titanate is confirmed by elemental mapping analysis. Ti K-edge X-ray absorption near-edge structure and Sn 3d X-ray photoelectron spectroscopy indicate the stabilization of tetravalent titanium ions in the spinel lattice of Li 4 Ti 5 O 12 and the formation of SnO 2 phase with tetravalent Sn oxidation state. The electrochemical measurements clearly demonstrate the promising functionality of the present nanocomposites as anode for lithium secondary batteries. The Li 4 Ti 5 O 12 –SnO 2 nanocomposites show larger discharge capacity and better cyclability than do the uncomposited Li 4 Ti 5 O 12 and SnO 2 phases, indicating the synergistic effect of nanocomposite formation on the electrode performance of Li 4 Ti 5 O 12 and SnO 2 . The present experimental findings underscore the validity of 2D nanostructured lithium titanate as a useful platform for the stabilization of nanocrystalline electrode materials and also for the improvement of their functionality.

  19. Isotropic three-dimensional T2 mapping of knee cartilage: Development and validation.

    Science.gov (United States)

    Colotti, Roberto; Omoumi, Patrick; Bonanno, Gabriele; Ledoux, Jean-Baptiste; van Heeswijk, Ruud B

    2018-02-01

    1) To implement a higher-resolution isotropic 3D T 2 mapping technique that uses sequential T 2 -prepared segmented gradient-recalled echo (Iso3DGRE) images for knee cartilage evaluation, and 2) to validate it both in vitro and in vivo in healthy volunteers and patients with knee osteoarthritis. The Iso3DGRE sequence with an isotropic 0.6 mm spatial resolution was developed on a clinical 3T MR scanner. Numerical simulations were performed to optimize the pulse sequence parameters. A phantom study was performed to validate the T 2 estimation accuracy. The repeatability of the sequence was assessed in healthy volunteers (n = 7). T 2 values were compared with those from a clinical standard 2D multislice multiecho (MSME) T 2 mapping sequence in knees of healthy volunteers (n = 13) and in patients with knee osteoarthritis (OA, n = 5). The numerical simulations resulted in 100 excitations per segment and an optimal radiofrequency (RF) excitation angle of 15°. The phantom study demonstrated a good correlation of the technique with the reference standard (slope 0.9 ± 0.05, intercept 0.2 ± 1.7 msec, R 2 ≥ 0.99). Repeated measurements of cartilage T 2 values in healthy volunteers showed a coefficient of variation of 5.6%. Both Iso3DGRE and MSME techniques found significantly higher cartilage T 2 values (P < 0.03) in OA patients. Iso3DGRE precision was equal to that of the MSME T 2 mapping in healthy volunteers, and significantly higher in OA (P = 0.01). This study successfully demonstrated that high-resolution isotropic 3D T 2 mapping for knee cartilage characterization is feasible, accurate, repeatable, and precise. The technique allows for multiplanar reformatting and thus T 2 quantification in any plane of interest. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:362-371. © 2017 International Society for Magnetic Resonance in Medicine.

  20. A Framework of Working Across Disciplines in Early Design and R&D of Large Complex Engineered Systems

    Science.gov (United States)

    McGowan, Anna-Maria Rivas; Papalambros, Panos Y.; Baker, Wayne E.

    2015-01-01

    This paper examines four primary methods of working across disciplines during R&D and early design of large-scale complex engineered systems such as aerospace systems. A conceptualized framework, called the Combining System Elements framework, is presented to delineate several aspects of cross-discipline and system integration practice. The framework is derived from a theoretical and empirical analysis of current work practices in actual operational settings and is informed by theories from organization science and engineering. The explanatory framework may be used by teams to clarify assumptions and associated work practices, which may reduce ambiguity in understanding diverse approaches to early systems research, development and design. The framework also highlights that very different engineering results may be obtained depending on work practices, even when the goals for the engineered system are the same.

  1. Type D (distressed) personality in primary care patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Nefs, Giesje; Pouwer, Francois; Pop, Victor J M

    2012-01-01

    D Scale-14 (DS14) in type 2 diabetes patients. METHODS: 1553 primary care patients with type 2 diabetes were assessed for demographic, clinical, lifestyle and psychological characteristics in 2007. A subgroup (n=1012) completed the DS14 again 1 year later. RESULTS: The two-factor model of the Type D...... or physiological risk factors, but Type D women had a more sedentary lifestyle (p=.003). Type D patients experienced less social support and more stressful life events, loneliness, and more depressed mood, anhedonia and anxiety (p0......OBJECTIVE: In cardiovascular research, Type D personality (high negative affectivity and social inhibition) has been associated with a more than 3-fold increased risk of adverse health outcomes. This study examined the validity and clinical correlates of the Type D construct as assessed by the Type...

  2. CryoSat-2: Post launch performance of SIRAL-2 and its calibration/validation

    Science.gov (United States)

    Cullen, Robert; Francis, Richard; Davidson, Malcolm; Wingham, Duncan

    2010-05-01

    the use of ocean calibration zones and radar transponders. 3. CRYOSAT-2 OVERALL PERFORMANCE & VALIDATION PLANNING Validating such retrievals derived from a phase coherent pulse-width limited polar observing radar altimeter, such as SIRAL, is not a simple one [4]. In order to fully understand all the respective error co-variances it is necessary to acquire many different types of in-situ measurements (GPR, neutron probe density profiles, drilled and electromagnetic derived sea-ice thicknesses, for example) in highly inhospitable regions of the cryosphere at key times of the year. In order to correlate retrievals from CryoSat with the in-situ data it was decided early in the CryoSat development that an aircraft borne radar altimeter with similar functionality to SIRAL would provide the necessary link, albeit on the smaller scale, and provide pre-launch incite into expected performances and issues. In 2001 ESA commenced the development of its own prototype radar altimeter that mimics the functionality of SIRAL. Similar to SIRAL, but with subtle functional differences, the airborne SAR/Interferometric Radar Altimeter System (ASIRAS) has now been the centre piece instrument for a number of large scale land and sea ice field campaigns in the Arctic during spring and autumn 2004, 2006 and 2008. Additional smaller science/test campaigns have taken place in March 2003 (Svalbard), March 2005 (Bay of Bothnia), March 2006 (Western Greenland) and April 2007 (CryoVEx 2007 in Svalbard). It is a credit to all parties that constitute the CryoSat Validation and Retrieval Team (CVRT) for the coordination, planning, acquisition of in-situ and airborne measurements and the subsequent processing and distributing of its data for analysis. CVRT has a robust infrastructure in place for validating its level 2 products derived from an operational CryoSat-2. 4. REFERENCES [1] http://www.esa.int/livingplanet/cryosat [2] Wingham, D. J., Francis, C. R., Baker, S., Bouzinac, C., Cullen, R., de

  3. Validating (d,pγ) as a surrogate for neutron capture

    International Nuclear Information System (INIS)

    Ratkiewicz, A.; Cizewski, J. A.; Pain, S. D.; Adekola, A. S.; Burke, J. T.; Casperson, R. J.; Fotiadis, Nikolaos; McCleskey, M.; Burcher, S.; Shand, C. M; Austin, R. A. E.; Baugher, T.; Carpenter, M. P.; Devlin, Matthew James; Escher, J. E.; Hardy, S.; Hatarik, R.; Howard, M. E.; Hughes, R. O.; Jones, K. L.; Kozub, R. L.; Lister, C. J.; Manning, B.; O'Donnell, John M.; Peters, W. A.; Ross, T. J.; Scielzo, N. D.; Seweryniak, D.; Zhu, S.

    2015-01-01

    The r-process is responsible for creating roughly half of the elements heavier than iron. It has recently become understood that the rates at which neutron capture reactions proceed at late times in the r-process may dramatically affect the final abundance pattern. However, direct measurements of neutron capture reaction rates on exotic nuclei are exceptionally difficult, necessitating the development of indirect approaches such as the surrogate technique. The (d,pγ) reaction at low energies was identified as a promising surrogate for the (n,γ) reaction, as both reactions share many characteristics. We report on a program to validate (d,pγ) as a surrogate for (n,γ) using 95Mo as a target. The experimental campaign includes direct measurements of the γ-ray intensities from the decay of excited states populated in the 95Mo(n,γ) and 95Mo(d,pγ) reactions.

  4. J2EE : frameworks de la capa de presentació

    OpenAIRE

    Vives Bernat, Melchor

    2011-01-01

    Estudi dels marcs de treball Java EE per la capa de presentació d'aplicacions web complexes. Estudio de los marcos de trabajo Java EE para la capa de presentación de aplicaciones web complejas. Study of the Java EE frameworks for the presentation layer of complex web applications.

  5. Examination of the MMPI-2 restructured form (MMPI-2-RF) validity scales in civil forensic settings: findings from simulation and known group samples.

    Science.gov (United States)

    Wygant, Dustin B; Ben-Porath, Yossef S; Arbisi, Paul A; Berry, David T R; Freeman, David B; Heilbronner, Robert L

    2009-11-01

    The current study examined the effectiveness of the MMPI-2 Restructured Form (MMPI-2-RF; Ben-Porath and Tellegen, 2008) over-reporting indicators in civil forensic settings. The MMPI-2-RF includes three revised MMPI-2 over-reporting validity scales and a new scale to detect over-reported somatic complaints. Participants dissimulated medical and neuropsychological complaints in two simulation samples, and a known-groups sample used symptom validity tests as a response bias criterion. Results indicated large effect sizes for the MMPI-2-RF validity scales, including a Cohen's d of .90 for Fs in a head injury simulation sample, 2.31 for FBS-r, 2.01 for F-r, and 1.97 for Fs in a medical simulation sample, and 1.45 for FBS-r and 1.30 for F-r in identifying poor effort on SVTs. Classification results indicated good sensitivity and specificity for the scales across the samples. This study indicates that the MMPI-2-RF over-reporting validity scales are effective at detecting symptom over-reporting in civil forensic settings.

  6. Sensitivity and uncertainty in flood inundation modelling – concept of an analysis framework

    Directory of Open Access Journals (Sweden)

    T. Weichel

    2007-01-01

    Full Text Available After the extreme flood event of the Elbe in 2002 the definition of flood risk areas by law and their simulation became more important in Germany. This paper describes a concept of an analysis framework to improve the localisation and duration of validity of flood inundation maps. The two-dimensional finite difference model TrimR2D is used and linked to a Monte-Carlo routine for parameter sampling as well as to selected performance measures. The purpose is the investigation of the impact of different spatial resolutions and the influence of changing land uses in the simulation of flood inundation areas. The technical assembling of the framework is realised and beside the model calibration, first tests with different parameter ranges were done. Preliminary results show good correlations with observed data, but the investigation of shifting land uses reflects only poor changes in the flood extension.

  7. Incremental validity of the MMPI-2-RF over-reporting scales and RBS in assessing the veracity of memory complaints.

    Science.gov (United States)

    Gervais, Roger O; Ben-Porath, Yossef S; Wygant, Dustin B; Sellbom, Martin

    2010-06-01

    The Response Bias Scale (RBS) has been found to be a better predictor of over-reported memory complaints than Minnesota Multiphasic Personality Inventory-2 (MMPI-2) F, Back Infrequency (Fb), Infrequency-Psychopathology (Fp), and FBS scales. The MMPI-2-Restructured Form (RF) validity scales were designed to meet or exceed the sensitivity of their MMPI-2 counterparts to symptom over-reporting. This study examined the incremental validity of MMPI-2-RF validity scales and RBS in assessing memory complaints. The MMPI-2-RF over-reporting validity scales were more strongly associated with mean Memory Complaints Inventory scores than their MMPI-2 counterparts (d = 0.22 to 0.49). RBS showed the strongest relationship with memory complaints. Regression analyses demonstrated the incremental validity of the MMPI-2-RF Infrequent Responses, Infrequent Psychopathology Responses, Infrequent Somatic Responses, and FBS-r scales relative to MMPI-2 F, Fp, and FBS in predicting memory complaints. This is consistent with the development objectives of the MMPI-2-RF validity scales as more efficient and sensitive measures of symptom over-reporting.

  8. A Flexible Framework for Magnetic Measurements

    CERN Document Server

    Inglese, V; Buzio, M

    2009-01-01

    The work presented in this Ph.D. thesis covers the specification, design, prototyping, and validation of a new version of a magnetic measurement control, acquisition, and data analysis software package: the Flexible Framework for Magnetic Measurements (FFMM). FFMM constitutes the software part of the new platform for magnetic measurements, including also new high-performance hardware, developed at the European Organization for Nuclear Research (CERN) in cooperation with the Department of Engineering of the University of Sannio. FFMM is conceived as a unified solution to drive all the existing and future park of measurement systems (mainly magnetic but also optical, mechanical, etc.). The effort for the series test of the LHC superconducting magnets highlighted limitations in the measurement control and acquisition programs, mainly associated with the relatively long time needed for a development iteration (the cycle of specification-programming-debugging-validation). Moreover, the software capabilities needed...

  9. A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

    International Nuclear Information System (INIS)

    Fu Dongshan; Kuduvalli, Gopinath

    2008-01-01

    The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33±0.16 mm (s.d.) in overall translation and 0.29 deg. ±0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34±0.16 mm (s.d.), 0.40±0.2 mm (s.d.), and 0.51±0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor

  10. Amphiphilic polymer promoted assembly of macroporous graphene/SnO2 frameworks with tunable porosity for high-performance lithium storage.

    Science.gov (United States)

    Huang, Yanshan; Wu, Dongqing; Wang, Jinzuan; Han, Sheng; Lv, Lu; Zhang, Fan; Feng, Xinliang

    2014-06-12

    3D macroporous graphene/SnO2 frameworks (MGTFs) are fabricated by amphiphilic polymer-promoted assembly method, which exhibit controllable macroporous structure and outstanding lithium storage performance. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Three new d10 transition metal selenites containing PO4 tetrahedron: Cd7(HPO4)2(PO4)2(SeO3)2, Cd6(PO4)1.34(SeO3)4.66 and Zn3(HPO4)(SeO3)2(H2O)

    Science.gov (United States)

    Ma, Yun-Xiang; Gong, Ya-Ping; Hu, Chun-li; Mao, Jiang-Gao; Kong, Fang

    2018-06-01

    Three new d10 transition metal selenites containing PO4 tetrahedron, namely, Cd7(HPO4)2(PO4)2(SeO3)2 (1), Cd6(PO4)1.34(SeO3)4.66 (2) and Zn3(HPO4)(SeO3)2(H2O) (3), have been synthesized by hydrothermal reaction. They feature three different structural types. Compound 1 exhibits a novel 3D network composed of 3D cadmium selenite open framework with phosphate groups filled in the 1D helical tunnels. The structure of compound 2 displays a new 3D framework consisted of 2D cadmium oxide layers bridged by SeO3 and PO4 groups. Compound 3 is isostructural with the reported solids of Co3(SeO3)3-x(PO3OH)x(H2O) when x is equal to 1.0. Its structure could be viewed as a 3D zinc oxide open skeleton with SeO3 and HPO4 polyhedra attached on the wall of the tunnels. They represent the only examples in metal selenite phosphates in addition to the above cobalt compounds. Optical diffuse reflectance spectra revealed that these solids are insulators, which are consistent with the results of band structure computations based on DFT algorithm.

  12. Syntheses, structures, and IR spectroscopic characterization of new uranyl sulfate/selenate 1D-chain, 2D-sheet and 3D-framework

    Energy Technology Data Exchange (ETDEWEB)

    Ling Jie; Sigmon, Ginger E.; Ward, Matthew; Roback, Nancy; Burns, Peter C. [Dept. of Civil Engineering and Geological Science, Univ. of Notre Dame, IN (United States)

    2010-07-01

    Three uranyl sulfates, (C{sub 6}H{sub 20}N{sub 4})[(UO{sub 2}){sub 2} . (SO{sub 4}){sub 4}(H{sub 2}O){sub 2}](H{sub 2}O){sub 6} (TETAUS), (C{sub 15}H{sub 14}N{sub 3})[(UO{sub 2}) . (SO{sub 4}){sub 2}](NO{sub 3})(H{sub 2}O){sub 2} (TPUS), and K{sub 2}[(UO{sub 2})(SO{sub 4}){sub 2}(H{sub 2}O)] . H{sub 2}O (KUS), and two uranyl selenates, K(H{sub 3}O)[(UO{sub 2}){sub 2} . (SeO{sub 4}){sub 3}(H{sub 2}O)](H{sub 2}O){sub 6} (KUSe) and (H{sub 3}O){sub 2}[(UO{sub 2}){sub 2}(SeO{sub 4}){sub 3} . (H{sub 2}O)] (USe), were synthesized by slow evaporation of aqueous solutions at room temperature. TETAUS crystallizes in space group P anti 1, a = 6.7186(5) A, b = 9.2625(7) A, c = 13.1078(9) A, {alpha} = 72.337(2) , {beta} = 89.198(2) , {gamma} = 70.037(1) , V = 726.89(9) A{sup 3}, Z = 1. TPUS is triclinic, P anti 1, a = 6.9732(7) A, b = 13.569(1) A, c = 13.641(1) A, {alpha} = 111.809(2) , {beta} = 102.386(2) , {gamma} = 93.833(2) , V = 1150.0(2) A{sup 3}, Z = 2. KUS is orthorhombic, Cmca, a = 12.171(2) A, b = 16.689(3) A, c = 10.997(2) A, V = 2233.8(6) A{sup 3}, Z = 8. These uranyl sulfates are built from infinite one-dimensional uranyl sulfate chains with different topologies. KUSe is monoclinic, P2{sub 1}/n, a = 14.715(1) A, b = 10.1557(7) A, c = 15.833(1) A, {beta} = 114.415(1) , V = 2154.5(3) A{sup 3}, Z = 4. Its structure is based on a two-dimensional uranyl selenate sheet. USe crystallizes in space group P2{sub 1}/c, a = 10.6124(2) A, b = 14.7717(3) A, c = 13.7139(3) A, {beta} = 96.989(1) , V = 2133.86(8) A{sup 3}, Z = 4, with a complex three-dimensional uranyl selenate framework containing channels extending in three directions. (orig.)

  13. Geologic Framework Model (GFM2000)

    International Nuclear Information System (INIS)

    T. Vogt

    2004-01-01

    the geologic framework model (200 feet [61 meters]), discussed in Section 6.4.2, limits the size of features that can be resolved by the model but is appropriate for the distribution of data available and its intended use. Uncertainty and limitations are discussed in Section 6.6 and model validation is discussed in Section 7

  14. Geologic Framework Model (GFM2000)

    Energy Technology Data Exchange (ETDEWEB)

    T. Vogt

    2004-08-26

    geologic framework model (200 feet [61 meters]), discussed in Section 6.4.2, limits the size of features that can be resolved by the model but is appropriate for the distribution of data available and its intended use. Uncertainty and limitations are discussed in Section 6.6 and model validation is discussed in Section 7.

  15. Colaborated Architechture Framework for Composition UML 2.0 in Zachman Framework

    Science.gov (United States)

    Hermawan; Hastarista, Fika

    2016-01-01

    Zachman Framework (ZF) is the framework of enterprise architechture that most widely adopted in the Enterprise Information System (EIS) development. In this study, has been developed Colaborated Architechture Framework (CAF) to collaborate ZF with Unified Modeling Language (UML) 2.0 modeling. The CAF provides the composition of ZF matrix that each cell is consist of the Model Driven architechture (MDA) from the various UML models and many Software Requirement Specification (SRS) documents. Implementation of this modeling is used to develops Enterprise Resource Planning (ERP). Because ERP have a coverage of applications in large numbers and complexly relations, it is necessary to use Agile Model Driven Design (AMDD) approach as an advanced method to transforms MDA into components of application modules with efficiently and accurately. Finally, through the using of the CAF, give good achievement in fullfilment the needs from all stakeholders that are involved in the overall process stage of Rational Unified Process (RUP), and also obtaining a high satisfaction to fullfiled the functionality features of the ERP software in PT. Iglas (Persero) Gresik.

  16. Cross-cultural adaptation and reliability and validity of the Dutch Patient-Rated Tennis Elbow Evaluation (PRTEE-D).

    Science.gov (United States)

    van Ark, Mathijs; Zwerver, Johannes; Diercks, Ronald L; van den Akker-Scheek, Inge

    2014-08-11

    Lateral Epicondylalgia (LE) is a common injury for which no reliable and valid measure exists to determine severity in the Dutch language. The Patient-Rated Tennis Elbow Evaluation (PRTEE) is the first questionnaire specifically designed for LE but in English. The aim of this study was to translate into Dutch and cross-culturally adapt the PRTEE and determine reliability and validity of the PRTEE-D (Dutch version). The PRTEE was cross-culturally adapted according to international guidelines. Participants (n = 122) were asked to fill out the PRTEE-D twice with a one week interval to assess test-retest reliability. Internal consistency of the PRTEE-D was determined by calculating Crohnbach's alphas for the questionnaire and subscales. Intraclass Correlation Coefficients (ICC) were calculated for the overall PRTEE-D score, pain and function subscale and individual questions to determine test-retest reliability. Additionally, the Disabilities for the Arm, Shoulder and Hand questionnaire (DASH) and Visual Analogue Scale (VAS) pain scores were obtained from 30 patients to assess construct validity; Spearman's correlation coefficients were calculated between the PRTEE-D (subscales) and DASH and VAS-pain scores. The PRTEE was successfully cross-culturally adapted into Dutch (PRTEE-D). Crohnbach's alpha for the first assessment of the PRTEE-D was 0.98; Crohnbach's alpha was 0.93 for the pain subscale and 0.97 for the function subscale. ICC for the PRTEE-D was 0.98; subscales also showed excellent ICC values (pain scale 0.97 and function scale 0.97). A significant moderate correlation exists between PRTEE-D and DASH (0.65) and PRTEE-D and VAS pain (0.68). The PRTEE was successfully cross-culturally adapted and this study showed that the PRTEE-D is reliable and valid to obtain an indication of severity of LE. An easy-to-use instrument for practitioners is now available and this facilitates comparing Dutch and international research data.

  17. Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function.

    Science.gov (United States)

    Liu, Jing; Feng, Li; Shen, Hsin-Wei; Zhu, Chengcheng; Wang, Yan; Mukai, Kanae; Brooks, Gabriel C; Ordovas, Karen; Saloner, David

    2017-08-01

    This work presents a highly-accelerated, self-gated, free-breathing 3D cardiac cine MRI method for cardiac function assessment. A golden-ratio profile based variable-density, pseudo-random, Cartesian undersampling scheme was implemented for continuous 3D data acquisition. Respiratory self-gating was achieved by deriving motion signal from the acquired MRI data. A multi-coil compressed sensing technique was employed to reconstruct 4D images (3D+time). 3D cardiac cine imaging with self-gating was compared to bellows gating and the clinical standard breath-held 2D cine imaging for evaluation of self-gating accuracy, image quality, and cardiac function in eight volunteers. Reproducibility of 3D imaging was assessed. Self-gated 3D imaging provided an image quality score of 3.4 ± 0.7 vs 4.0 ± 0 with the 2D method (p = 0.06). It determined left ventricular end-systolic volume as 42.4 ± 11.5 mL, end-diastolic volume as 111.1 ± 24.7 mL, and ejection fraction as 62.0 ± 3.1%, which were comparable to the 2D method, with bias ± 1.96 × SD of -0.8 ± 7.5 mL (p = 0.90), 2.6 ± 3.3 mL (p = 0.84) and 1.4 ± 6.4% (p = 0.45), respectively. The proposed 3D cardiac cine imaging method enables reliable respiratory self-gating performance with good reproducibility, and provides comparable image quality and functional measurements to 2D imaging, suggesting that self-gated, free-breathing 3D cardiac cine MRI framework is promising for improved patient comfort and cardiac MRI scan efficiency.

  18. Hydrothermal synthesis and characterization of a new three-dimensional hybrid zinc phosphate [Zn2(HPO4)2(4,4'-bipy)].3H2O with neutral porous framework

    International Nuclear Information System (INIS)

    Wang Lei; Yang Ming; Li Guanghua; Shi Zhan; Feng Shouhua

    2006-01-01

    Employing 4,4'-bipyridine as a bridged ligand, a new three-dimensional (3-D) hybrid zinc phosphate [Zn 2 (HPO 4 ) 2 (4,4'-bipy)].3H 2 O has been prepared under hydrothermal conditions and characterized by single crystal X-ray diffraction. This compound crystallizes in the monoclinic space group C2/c, with cell parameters, a=21.188(4)A, b=10.229(2)A, c=9.0656(18)A, β=90.21(3) o , V=1964.8(7)A 3 and Z=4. The connectivity of the ZnO 3 N and HPO 4 tetrahedra results in a 2-D neutral layer that with interesting 4,8 2 net along the bc plane. Furthermore, the 4,4'-bipyridine molecule links the 4,8 2 net into a 3-D structure. The water molecules sit in the middle of the channels and interact with the framework via hydrogen bonds. The compound exhibits intense photoluminescence at room temperature

  19. Computing K and D meson masses with Nf=2+1+1 twisted mass lattice QCD

    International Nuclear Information System (INIS)

    Baron, Remi; Blossier, Benoit; Boucaud, Philippe

    2010-05-01

    We discuss the computation of the mass of the K and D mesons within the framework of N f =2+1+1 twisted mass lattice QCD from a technical point of view. These quantities are essential, already at the level of generating gauge configurations, being obvious candidates to tune the strange and charm quark masses to their physical values. In particular, we address the problems related to the twisted mass flavor and parity symmetry breaking, which arise when considering a non-degenerate (c,s) doublet. We propose and verify the consistency of three methods to extract the K and D meson masses in this framework. (orig.)

  20. Elastic full waveform inversion based on the homogenization method: theoretical framework and 2-D numerical illustrations

    Science.gov (United States)

    Capdeville, Yann; Métivier, Ludovic

    2018-05-01

    Seismic imaging is an efficient tool to investigate the Earth interior. Many of the different imaging techniques currently used, including the so-called full waveform inversion (FWI), are based on limited frequency band data. Such data are not sensitive to the true earth model, but to a smooth version of it. This smooth version can be related to the true model by the homogenization technique. Homogenization for wave propagation in deterministic media with no scale separation, such as geological media, has been recently developed. With such an asymptotic theory, it is possible to compute an effective medium valid for a given frequency band such that effective waveforms and true waveforms are the same up to a controlled error. In this work we make the link between limited frequency band inversion, mainly FWI, and homogenization. We establish the relation between a true model and an FWI result model. This relation is important for a proper interpretation of FWI images. We numerically illustrate, in the 2-D case, that an FWI result is at best the homogenized version of the true model. Moreover, it appears that the homogenized FWI model is quite independent of the FWI parametrization, as long as it has enough degrees of freedom. In particular, inverting for the full elastic tensor is, in each of our tests, always a good choice. We show how the homogenization can help to understand FWI behaviour and help to improve its robustness and convergence by efficiently constraining the solution space of the inverse problem.

  1. Crossover from BCS to composite boson (local pair) superconductivity in quasi-2D systems

    International Nuclear Information System (INIS)

    Gorbar, E.V.; Loktev, V.M.; Sharapov, S.G.

    1995-01-01

    The crossover from cooperative Cooper pairing to independent bound state (composite bosons) formation and condensation in quasi-2 D systems is studied. It is shown that at low carrier density the critical superconducting temperature is equal to the temperature of Bose-condensation of ideal quasi-2 D Bose-gas with heavy dynamical mass, meanwhile at high densities the BCS result remains valid. 15 refs

  2. A general framework and review of scatter correction methods in cone beam CT. Part 2: Scatter estimation approaches

    International Nuclear Information System (INIS)

    Ruehrnschopf and, Ernst-Peter; Klingenbeck, Klaus

    2011-01-01

    The main components of scatter correction procedures are scatter estimation and a scatter compensation algorithm. This paper completes a previous paper where a general framework for scatter compensation was presented under the prerequisite that a scatter estimation method is already available. In the current paper, the authors give a systematic review of the variety of scatter estimation approaches. Scatter estimation methods are based on measurements, mathematical-physical models, or combinations of both. For completeness they present an overview of measurement-based methods, but the main topic is the theoretically more demanding models, as analytical, Monte-Carlo, and hybrid models. Further classifications are 3D image-based and 2D projection-based approaches. The authors present a system-theoretic framework, which allows to proceed top-down from a general 3D formulation, by successive approximations, to efficient 2D approaches. A widely useful method is the beam-scatter-kernel superposition approach. Together with the review of standard methods, the authors discuss their limitations and how to take into account the issues of object dependency, spatial variance, deformation of scatter kernels, external and internal absorbers. Open questions for further investigations are indicated. Finally, the authors refer on some special issues and applications, such as bow-tie filter, offset detector, truncated data, and dual-source CT.

  3. Rényi entropies and topological quantum numbers in 2D gapped Dirac materials

    International Nuclear Information System (INIS)

    Bolívar, Juan Carlos; Romera, Elvira

    2017-01-01

    New topological quantum numbers are introduced by analyzing complexity measures and relative Rényi entropies in silicene in the presence of perpendicular electric and magnetic fields. These topological quantum numbers characterize the topological insulator and band insulator phases in silicene. In addition, we have found that, these information measures reach extremum values at the charge neutrality points. These results are valid for other 2D gapped Dirac materials analogous to silicene with a buckled honeycomb structure and a significant spin-orbit coupling. - Highlights: • Topological quantum numbers (Chern-like numbers) by Rényi entropies in silicene. • These topological numbers characterize silicene topological and band insulator phases. • These information measures reach extremum values at the charge neutrality points. • These results are valid for other 2D gapped Dirac materials analogous to silicene.

  4. Modeling and protein engineering studies of active and inactive states of human dopamine D2 receptor (D2R) and investigation of drug/receptor interactions.

    Science.gov (United States)

    Salmas, Ramin Ekhteiari; Yurtsever, Mine; Stein, Matthias; Durdagi, Serdar

    2015-05-01

    Homology model structures of the dopamine D2 receptor (D2R) were generated starting from the active and inactive states of β2-adrenergic crystal structure templates. To the best of our knowledge, the active conformation of D2R was modeled for the first time in this study. The homology models are built and refined using MODELLER and ROSETTA programs. Top-ranked models have been validated with ligand docking simulations and in silico Alanine-scanning mutagenesis studies. The derived extra-cellular loop region of the protein models is directed toward the binding site cavity which is often involved in ligand binding. The binding sites of protein models were refined using induced fit docking to enable the side-chain refinement during ligand docking simulations. The derived models were then tested using molecular modeling techniques on several marketed drugs for schizophrenia. Alanine-scanning mutagenesis and molecular docking studies gave similar results for marketed drugs tested. We believe that these new D2 receptor models will be very useful for a better understanding of the mechanisms of action of drugs to be targeted to the binding sites of D2Rs and they will contribute significantly to drug design studies involving G-protein-coupled receptors in the future.

  5. Validation of the 10-item Centre for Epidemiological Studies Depression Scale (CES-D-10) in Zulu, Xhosa and Afrikaans populations in South Africa.

    Science.gov (United States)

    Baron, Emily Claire; Davies, Thandi; Lund, Crick

    2017-01-09

    The 10-item Centre for Epidemiological Studies Depression Scale (CES-D-10) is a depression screening tool that has been used in the South African National Income Dynamics Study (NIDS), a national household panel study. This screening tool has not yet been validated in South Africa. This study aimed to establish the reliability and validity of the CES-D-10 in Zulu, Xhosa and Afrikaans. The CES-D-10's psychometric properties were also compared to the Patient Health Questionnaire (PHQ-9), a depression screening tool already validated in South Africa. Stratified random samples of Xhosa, Afrikaans and Zulu-speaking participants aged 15 years or older (N = 944) were recruited from Cape Town Metro and Ethekwini districts. Face-to-face interviews included socio-demographic questions, the CES-D-10, Patient Health Questionnaire (PHQ-9), and WHO Disability Assessment Schedule 2.0 (WHODAS). Major depression was determined using the Mini International Neuropsychiatric Interview. All instruments were translated and back-translated to English. Construct validity was examined using exploratory factor analysis with varimax rotation. Receiver Operating Characteristics (ROC) curves were used to investigate the CES-D-10 and PHQ-9's criterion validity, and compared using the DeLong method. Overall, 6.6, 18.0 and 6.9% of the Zulu, Afrikaans and Xhosa samples were diagnosed with depression, respectively. The CES-D-10 had acceptable internal consistency across samples (α = 0.69-0.89), and adequate concurrent validity, when compared to the PHQ-9 and WHODAS. The CES-D-10 area under the Receiver Operator Characteristic curve was good to excellent: 0.81 (95% CI 0.71-0.90) for Zulu, 0.93 (95% CI 0.90-0.96) for Afrikaans, and 0.94 (95% CI 0.89-0.99) for Xhosa. A cut-off of 12, 11 and 13 for Zulu, Afrikaans and Xhosa, respectively, generated the most balanced sensitivity, specificity and positive predictive value (Zulu: 71.4, 72.6% and 16.1%; Afrikaans: 84.6%, 84.0%, 53.7%; Xhosa: 81

  6. WE-AB-BRA-07: Quantitative Evaluation of 2D-2D and 2D-3D Image Guided Radiation Therapy for Clinical Trial Credentialing, NRG Oncology/RTOG

    Energy Technology Data Exchange (ETDEWEB)

    Giaddui, T; Yu, J; Xiao, Y [Thomas Jefferson University, Philadelphia, PA (United States); Jacobs, P [MIM Software, Inc, Cleavland, Ohio (United States); Manfredi, D; Linnemann, N [IROC Philadelphia, RTQA Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: 2D-2D kV image guided radiation therapy (IGRT) credentialing evaluation for clinical trial qualification was historically qualitative through submitting screen captures of the fusion process. However, as quantitative DICOM 2D-2D and 2D-3D image registration tools are implemented in clinical practice for better precision, especially in centers that treat patients with protons, better IGRT credentialing techniques are needed. The aim of this work is to establish methodologies for quantitatively reviewing IGRT submissions based on DICOM 2D-2D and 2D-3D image registration and to test the methodologies in reviewing 2D-2D and 2D-3D IGRT submissions for RTOG/NRG Oncology clinical trials qualifications. Methods: DICOM 2D-2D and 2D-3D automated and manual image registration have been tested using the Harmony tool in MIM software. 2D kV orthogonal portal images are fused with the reference digital reconstructed radiographs (DRR) in the 2D-2D registration while the 2D portal images are fused with DICOM planning CT image in the 2D-3D registration. The Harmony tool allows alignment of the two images used in the registration process and also calculates the required shifts. Shifts calculated using MIM are compared with those submitted by institutions for IGRT credentialing. Reported shifts are considered to be acceptable if differences are less than 3mm. Results: Several tests have been performed on the 2D-2D and 2D-3D registration. The results indicated good agreement between submitted and calculated shifts. A workflow for reviewing these IGRT submissions has been developed and will eventually be used to review IGRT submissions. Conclusion: The IROC Philadelphia RTQA center has developed and tested a new workflow for reviewing DICOM 2D-2D and 2D-3D IGRT credentialing submissions made by different cancer clinical centers, especially proton centers. NRG Center for Innovation in Radiation Oncology (CIRO) and IROC RTQA center continue their collaborative efforts to enhance

  7. WE-AB-BRA-07: Quantitative Evaluation of 2D-2D and 2D-3D Image Guided Radiation Therapy for Clinical Trial Credentialing, NRG Oncology/RTOG

    International Nuclear Information System (INIS)

    Giaddui, T; Yu, J; Xiao, Y; Jacobs, P; Manfredi, D; Linnemann, N

    2015-01-01

    Purpose: 2D-2D kV image guided radiation therapy (IGRT) credentialing evaluation for clinical trial qualification was historically qualitative through submitting screen captures of the fusion process. However, as quantitative DICOM 2D-2D and 2D-3D image registration tools are implemented in clinical practice for better precision, especially in centers that treat patients with protons, better IGRT credentialing techniques are needed. The aim of this work is to establish methodologies for quantitatively reviewing IGRT submissions based on DICOM 2D-2D and 2D-3D image registration and to test the methodologies in reviewing 2D-2D and 2D-3D IGRT submissions for RTOG/NRG Oncology clinical trials qualifications. Methods: DICOM 2D-2D and 2D-3D automated and manual image registration have been tested using the Harmony tool in MIM software. 2D kV orthogonal portal images are fused with the reference digital reconstructed radiographs (DRR) in the 2D-2D registration while the 2D portal images are fused with DICOM planning CT image in the 2D-3D registration. The Harmony tool allows alignment of the two images used in the registration process and also calculates the required shifts. Shifts calculated using MIM are compared with those submitted by institutions for IGRT credentialing. Reported shifts are considered to be acceptable if differences are less than 3mm. Results: Several tests have been performed on the 2D-2D and 2D-3D registration. The results indicated good agreement between submitted and calculated shifts. A workflow for reviewing these IGRT submissions has been developed and will eventually be used to review IGRT submissions. Conclusion: The IROC Philadelphia RTQA center has developed and tested a new workflow for reviewing DICOM 2D-2D and 2D-3D IGRT credentialing submissions made by different cancer clinical centers, especially proton centers. NRG Center for Innovation in Radiation Oncology (CIRO) and IROC RTQA center continue their collaborative efforts to enhance

  8. Acute D2/D3 dopaminergic agonism but chronic D2/D3 antagonism prevents NMDA antagonist neurotoxicity.

    Science.gov (United States)

    Farber, Nuri B; Nemmers, Brian; Noguchi, Kevin K

    2006-09-15

    Antagonists of the N-methyl-D-aspartate (NMDA) glutamate receptor, most likely by producing disinhibtion in complex circuits, acutely produce psychosis and cognitive disturbances in humans, and neurotoxicity in rodents. Studies examining NMDA Receptor Hypofunction (NRHypo) neurotoxicity in animals, therefore, may provide insights into the pathophysiology of psychotic disorders. Dopaminergic D2 and/or D3 agents can modify psychosis over days to weeks, suggesting involvement of these transmitter system(s). We studied the ability of D2/D3 agonists and antagonists to modify NRHypo neurotoxicity both after a one-time acute exposure and after chronic daily exposure. Here we report that D2/D3 dopamine agonists, probably via D3 receptors, prevent NRHypo neurotoxicity when given acutely. The protective effect with D2/D3 agonists is not seen after chronic daily dosing. In contrast, the antipsychotic haloperidol does not affect NRHypo neurotoxicity when given acutely at D2/D3 doses. However, after chronic daily dosing of 1, 3, or 5 weeks, haloperidol does prevent NRHypo neurotoxicity with longer durations producing greater protection. Understanding the changes that occur in the NRHypo circuit after chronic exposure to dopaminergic agents could provide important clues into the pathophysiology of psychotic disorders.

  9. Simulating Dynamic Stall in a 2D VAWT: Modeling strategy, verification and validation with Particle Image Velocimetry data

    International Nuclear Information System (INIS)

    Ferreira, C J Simao; Bijl, H; Bussel, G van; Kuik, G van

    2007-01-01

    The implementation of wind energy conversion systems in the built environment renewed the interest and the research on Vertical Axis Wind Turbines (VAWT), which in this application present several advantages over Horizontal Axis Wind Turbines (HAWT). The VAWT has an inherent unsteady aerodynamic behavior due to the variation of angle of attack with the angle of rotation, perceived velocity and consequentially Reynolds number. The phenomenon of dynamic stall is then an intrinsic effect of the operation of a Vertical Axis Wind Turbine at low tip speed ratios, having a significant impact in both loads and power. The complexity of the unsteady aerodynamics of the VAWT makes it extremely attractive to be analyzed using Computational Fluid Dynamics (CFD) models, where an approximation of the continuity and momentum equations of the Navier-Stokes equations set is solved. The complexity of the problem and the need for new design approaches for VAWT for the built environment has driven the authors of this work to focus the research of CFD modeling of VAWT on: .comparing the results between commonly used turbulence models: URANS (Spalart-Allmaras and k-ε) and large eddy models (Large Eddy Simulation and Detached Eddy Simulation) .verifying the sensitivity of the model to its grid refinement (space and time), .evaluating the suitability of using Particle Image Velocimetry (PIV) experimental data for model validation. The 2D model created represents the middle section of a single bladed VAWT with infinite aspect ratio. The model simulates the experimental work of flow field measurement using Particle Image Velocimetry by Simao Ferreira et al for a single bladed VAWT. The results show the suitability of the PIV data for the validation of the model, the need for accurate simulation of the large eddies and the sensitivity of the model to grid refinement

  10. Systematic validation of predicted microRNAs for cyclin D1

    International Nuclear Information System (INIS)

    Jiang, Qiong; Feng, Ming-Guang; Mo, Yin-Yuan

    2009-01-01

    MicroRNAs are the endogenous small non-coding RNA molecules capable of silencing protein coding genes at the posttranscriptional level. Based on computer-aided predictions, a single microRNA could have over a hundred of targets. On the other hand, a single protein-coding gene could be targeted by many potential microRNAs. However, only a relatively small number of these predicted microRNA/mRNA interactions are experimentally validated, and no systematic validation has been carried out using a reporter system. In this study, we used luciferease reporter assays to validate microRNAs that can silence cyclin D1 (CCND1) because CCND1 is a well known proto-oncogene implicated in a variety of types of cancers. We chose miRanda (http://www.microRNA.org) as a primary prediction method. We then cloned 51 of 58 predicted microRNA precursors into pCDH-CMV-MCS-EF1-copGFP and tested for their effect on the luciferase reporter carrying the 3'-untranslated region (UTR) of CCND1 gene. Real-time PCR revealed the 45 of 51 cloned microRNA precursors expressed a relatively high level of the exogenous microRNAs which were used in our validation experiments. By an arbitrary cutoff of 35% reduction, we identified 7 microRNAs that were able to suppress Luc-CCND1-UTR activity. Among them, 4 of them were previously validated targets and the rest 3 microRNAs were validated to be positive in this study. Of interest, we found that miR-503 not only suppressed the luciferase activity, but also suppressed the endogenous CCND1 both at protein and mRNA levels. Furthermore, we showed that miR-503 was able to reduce S phase cell populations and caused cell growth inhibition, suggesting that miR-503 may be a putative tumor suppressor. This study provides a more comprehensive picture of microRNA/CCND1 interactions and it further demonstrates the importance of experimental target validation

  11. The first 3D malonate bridged copper [Cu(O{sub 2}C-CH{sub 2}-CO{sub 2}H){sub 2}{center_dot}2H{sub 2}O]: Structure, properties and electronic structure

    Energy Technology Data Exchange (ETDEWEB)

    Seguatni, A., E-mail: seguatni@gmail.com [LBPC-INSERM U 698, Institut Galilee, Universite Paris XIII, 99, avenue J. B. Clement 93430, Villetaneuse (France); Fakhfakh, M. [Unite de recherche UR 12-30, Synthese et Structure de Materiaux Inorganiques, Faculte des Sciences de Bizerte, 7021 Zarzouna (Tunisia); Departement de Chimie, Universite du Quebec a Montreal, C.P. 8888, Succ. Centre-ville, Montreal, Que., H3C 3P8 (Canada); Smiri, L.S. [Unite de recherche UR 12-30, Synthese et Structure de Materiaux Inorganiques, Faculte des Sciences de Bizerte, 7021 Zarzouna (Tunisia); Gressier, P.; Boucher, F. [Institut des Materiaux Jean Rouxel, Universite de Nantes, CNRS, 2 rue de la Houssiniere, BP 32229, 44322 Nantes Cedex 3 (France); Jouini, N. [Departement de Chimie, Universite du Quebec a Montreal, C.P. 8888, Succ. Centre-ville, Montreal, Que., H3C 3P8 (Canada)

    2012-03-15

    A new inorganic-organic compound [Cu(O{sub 2}C-CH{sub 2}-CO{sub 2}H){sub 2}{center_dot}2H{sub 2}O] ([Cumal]) was hydrothermally synthesized and characterized by IR spectroscopy, thermal analysis and single crystal X-ray diffraction. [Cumal] is the first three-dimensional compound existing in the system Cu(II)-malonic acid-H{sub 2}O. Its framework is built up through carboxyl bridged copper where CuO{sub 6} octahedra are elongated with an almost D{sub 4h} symmetry (4+2) due to the Jahn-Teller effect. The magnetic properties were studied by measuring its magnetic susceptibility in the temperature range of 2-300 K indicating the existence of weak ferromagnetic interactions. The electronic structure of [Cumal] was calculated within the density functional theory (DFT) framework. Structural features are well reproduced using DFT structural optimizations and the optical spectra, calculated within the dielectric formalism, explain very well the light blue colour of the compound. It is shown that a GGA+U approach with a U{sub eff} value of about 6 eV is necessary for a better correlation with the experiment. - Graphical abstract: [Cu(O{sub 2}C-CH{sub 2}-CO{sub 2}H){sub 2}{center_dot}2H{sub 2}O]: the first 3D hybrid organic-inorganic compound built up carboxyl groups. The network presents a diamond-like structure achieved via carboxyl. Highlights: Black-Right-Pointing-Pointer A new organic-inorganic material with an unprecedented topology is synthesized. Black-Right-Pointing-Pointer Crystallographic structure is determined using single crystal X-ray diffraction. Black-Right-Pointing-Pointer Electronic structure is obtained from DFT, GGA+U calculation. Black-Right-Pointing-Pointer Framework can be described as formed from CuC{sub 4} tetrahedron sharing four corners. Black-Right-Pointing-Pointer This structure can be classified as an extended diamond structure.

  12. Expansion and Validation of the PAPA Framework

    Science.gov (United States)

    Woodward, Belle; Martin, Nancy; Imboden, Thomas

    2011-01-01

    In recent years, ethics has drawn increased interest from information technology and computer science practitioners as well as from academicians. This article investigates the issues outlined in the PAPA framework in today's environment and explores the possibility that new issues have emerged. Findings indicate that the ethicality of property…

  13. Fast multi-core based multimodal registration of 2D cross-sections and 3D datasets.

    Science.gov (United States)

    Scharfe, Michael; Pielot, Rainer; Schreiber, Falk

    2010-01-11

    Solving bioinformatics tasks often requires extensive computational power. Recent trends in processor architecture combine multiple cores into a single chip to improve overall performance. The Cell Broadband Engine (CBE), a heterogeneous multi-core processor, provides power-efficient and cost-effective high-performance computing. One application area is image analysis and visualisation, in particular registration of 2D cross-sections into 3D image datasets. Such techniques can be used to put different image modalities into spatial correspondence, for example, 2D images of histological cuts into morphological 3D frameworks. We evaluate the CBE-driven PlayStation 3 as a high performance, cost-effective computing platform by adapting a multimodal alignment procedure to several characteristic hardware properties. The optimisations are based on partitioning, vectorisation, branch reducing and loop unrolling techniques with special attention to 32-bit multiplies and limited local storage on the computing units. We show how a typical image analysis and visualisation problem, the multimodal registration of 2D cross-sections and 3D datasets, benefits from the multi-core based implementation of the alignment algorithm. We discuss several CBE-based optimisation methods and compare our results to standard solutions. More information and the source code are available from http://cbe.ipk-gatersleben.de. The results demonstrate that the CBE processor in a PlayStation 3 accelerates computational intensive multimodal registration, which is of great importance in biological/medical image processing. The PlayStation 3 as a low cost CBE-based platform offers an efficient option to conventional hardware to solve computational problems in image processing and bioinformatics.

  14. A framework for the testing and validation of the I and C system based on a simulator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Jun; Kwon, Kee Choon; Lee, Jang Soo [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The I and C system for a nuclear power plant should be developed as a prototype or mock-up from the concept phase of the development process, and the function and performance of the computer system also have to be tested and validated. If possible, the developed prototype or mock-up could receive the signals of a normal or abnormal operation status of a nuclear power plant and generate the proper requirement output signal. Using these processes, it can be verified that the status of a plant is changed to the design state or the state needed by the plant operator. A simulation-based conformity evaluation platform is an environment that can automate the testing and validation actions. A traditional testing and validation method defines the static test requirements and extracts the input data from the defined requirement using IO signal generation devices. On the contrary, a simulation-based test method can generate the real calculated input data from a simulator and send the signals to the test devices directly. In this paper, we developed a framework that can conduct a conformity evaluation based on a simulator and implement the communication and monitoring program.

  15. CFD Validation Experiment of a Mach 2.5 Axisymmetric Shock-Wave/Boundary-Layer Interaction

    Science.gov (United States)

    Davis, David O.

    2015-01-01

    Experimental investigations of specific flow phenomena, e.g., Shock Wave Boundary-Layer Interactions (SWBLI), provide great insight to the flow behavior but often lack the necessary details to be useful as CFD validation experiments. Reasons include: 1.Undefined boundary conditions Inconsistent results 2.Undocumented 3D effects (CL only measurements) 3.Lack of uncertainty analysis While there are a number of good subsonic experimental investigations that are sufficiently documented to be considered test cases for CFD and turbulence model validation, the number of supersonic and hypersonic cases is much less. This was highlighted by Settles and Dodsons [1] comprehensive review of available supersonic and hypersonic experimental studies. In all, several hundred studies were considered for their database.Of these, over a hundred were subjected to rigorous acceptance criteria. Based on their criteria, only 19 (12 supersonic, 7 hypersonic) were considered of sufficient quality to be used for validation purposes. Aeschliman and Oberkampf [2] recognized the need to develop a specific methodology for experimental studies intended specifically for validation purposes.

  16. An LUR/BME framework to estimate PM2.5 explained by on road mobile and stationary sources.

    Science.gov (United States)

    Reyes, Jeanette M; Serre, Marc L

    2014-01-01

    Knowledge of particulate matter concentrations Bayesian Maximum Entropy (BME) framework to estimate PM2.5 across the United States from 1999 to 2009. A cross-validation was done to determine the improvement of the estimate due to the LUR incorporation into BME. These results were applied to known diseases to determine predicted mortality coming from total PM2.5 as well as PM2.5 explained by major contributing sources. This method showed a mean squared error reduction of over 21.89% oversimple kriging. PM2.5 explained by on road mobile emissions and stationary emissions contributed to nearly 568,090 and 306,316 deaths, respectively, across the United States from 1999 to 2007.

  17. M(II)-dipyridylamide-based coordination frameworks (M=Mn, Co, Ni): Structural transformation

    Energy Technology Data Exchange (ETDEWEB)

    Tzeng, Biing-Chiau; Selvam, TamilSelvi; Tsai, Miao-Hsin

    2016-11-15

    A series of 1-D double-zigzag (([M(papx){sub 2}(H{sub 2}O){sub 2}](ClO{sub 4}){sub 2}){sub n}; M=Mn, x=s (1), x=o (3); M=Co, x=s (4), x=o (5); M=Ni, x=s (6), x=o (7)) and 2-D polyrotaxane ([Mn(paps){sub 2}(ClO{sub 4}){sub 2}]{sub n} (2)) frameworks were synthesized by reactions of M(ClO{sub 4}){sub 2} (M=Mn, Co, and Ni) with papx (paps, N,N’-bis(pyridylcarbonyl)-4,4’-diaminodiphenylthioether; papo, N,N’-bis(pyridylcarbonyl)-4,4’-diaminodiphenyl ether), which have been isolated and structurally characterized by X-ray diffraction. Based on powder X-ray diffraction (PXRD) experiments, heating the double-zigzag frameworks underwent structural transformation to give the respective polyrotaxane ones. Moreover, grinding the solid samples of the respective polyrotaxanes in the presence of moisture also resulted in the total conversion to the original double-zigzag frameworks. In this study, we have successfully extended studies to Mn{sup II}, Co{sup II}, and Ni{sup II} frameworks from the previous Zn{sup II}, Cd{sup II}, and Cu{sup II} ones, and interestingly such structural transformation is able to be proven experimentally by powder and single-crystal X-ray diffraction studies as well. - Graphical abstract: 1-D double-zigzag and 2-D polyrotaxane frameworks of M(II)-papx (x=s, o; M=Mn, Co, Ni) frameworks can be interconverted by heating and grinding in the presence of moiture, and such structural transformation has be proven experimentally by powder and single-crystal X-ray diffraction studies.

  18. Network Coding for Backhaul Offloading in D2D Cooperative Fog Data Networks

    Directory of Open Access Journals (Sweden)

    Ben Quinton

    2018-01-01

    Full Text Available Future distributed data networks are expected to be assisted by users cooperation and coding schemes. Given the explosive increase in the end-users’ demand for download of the content from the servers, in this paper, the implementation of instantly decodable network coding (IDNC is considered in full-duplex device-to-device (D2D cooperative fog data networks. In particular, this paper is concerned with designing efficient transmission schemes to offload traffic from the expensive backhaul of network servers by employing IDNC and users cooperation. The generalized framework where users send request for multiple packets and the transmissions are subject to erasure is considered. The optimal problem formulation is presented using the stochastic shortest path (SSP technique over the IDNC graph with induced subgraphs. However, as the optimal solution suffers from the intractability of being NP-hard, it is not suitable for real-time communications. The complexity of the problem is addressed by presenting a greedy heuristic algorithm used over the proposed graph model. The paper shows that by implementing IDNC in a full-duplex cooperative D2D network model significant reduction in the number of downloads required from the servers can be achieved, which will result in offloading of the backhaul servers and thus saving valuable servers’ resources. It is also shown that the performance of the proposed heuristic algorithm is very close to the optimal solution with much lower computational complexity.

  19. Validating the BISON fuel performance code to integral LWR experiments

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, R.L., E-mail: Richard.Williamson@inl.gov [Fuel Modeling and Simulation, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Gamble, K.A., E-mail: Kyle.Gamble@inl.gov [Fuel Modeling and Simulation, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Perez, D.M., E-mail: Danielle.Perez@inl.gov [Fuel Modeling and Simulation, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Novascone, S.R., E-mail: Stephen.Novascone@inl.gov [Fuel Modeling and Simulation, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Pastore, G., E-mail: Giovanni.Pastore@inl.gov [Fuel Modeling and Simulation, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Gardner, R.J., E-mail: Russell.Gardner@inl.gov [Fuel Modeling and Simulation, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Hales, J.D., E-mail: Jason.Hales@inl.gov [Fuel Modeling and Simulation, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Liu, W., E-mail: Wenfeng.Liu@anatech.com [ANATECH Corporation, 5435 Oberlin Dr., San Diego, CA 92121 (United States); Mai, A., E-mail: Anh.Mai@anatech.com [ANATECH Corporation, 5435 Oberlin Dr., San Diego, CA 92121 (United States)

    2016-05-15

    Highlights: • The BISON multidimensional fuel performance code is being validated to integral LWR experiments. • Code and solution verification are necessary prerequisites to validation. • Fuel centerline temperature comparisons through all phases of fuel life are very reasonable. • Accuracy in predicting fission gas release is consistent with state-of-the-art modeling and the involved uncertainties. • Rod diameter comparisons are not satisfactory and further investigation is underway. - Abstract: BISON is a modern finite element-based nuclear fuel performance code that has been under development at Idaho National Laboratory (INL) since 2009. The code is applicable to both steady and transient fuel behavior and has been used to analyze a variety of fuel forms in 1D spherical, 2D axisymmetric, or 3D geometries. Code validation is underway and is the subject of this study. A brief overview of BISON's computational framework, governing equations, and general material and behavioral models is provided. BISON code and solution verification procedures are described, followed by a summary of the experimental data used to date for validation of Light Water Reactor (LWR) fuel. Validation comparisons focus on fuel centerline temperature, fission gas release, and rod diameter both before and following fuel-clad mechanical contact. Comparisons for 35 LWR rods are consolidated to provide an overall view of how the code is predicting physical behavior, with a few select validation cases discussed in greater detail. Results demonstrate that (1) fuel centerline temperature comparisons through all phases of fuel life are very reasonable with deviations between predictions and experimental data within ±10% for early life through high burnup fuel and only slightly out of these bounds for power ramp experiments, (2) accuracy in predicting fission gas release appears to be consistent with state-of-the-art modeling and with the involved uncertainties and (3) comparison

  20. WE-AB-BRA-08: Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration

    Energy Technology Data Exchange (ETDEWEB)

    Ouadah, S; Jacobson, M; Stayman, JW; Siewerdsen, JH [Johns Hopkins University, Baltimore, MD (United States); Ehtiati, T [Siemens Medical Solutions USA, Inc., Hoffman Estates, IL (United States)

    2016-06-15

    Purpose: Intraoperative C-arm cone-beam CT (CBCT) is subject to artifacts arising from patient motion during the fairly long (∼5–20 s) scan times. We present a fiducial free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in geometric calibration. Methods: A 3D-2D registration process was used to register each projection to DRRs computed from the 3D image by maximizing gradient orientation (GO) using the CMA-ES optimizer. The resulting rigid 6 DOF transforms were applied to the system projection matrices, and a 3D image was reconstructed via model-based image reconstruction (MBIR, which accommodates the resulting noncircular orbit). Experiments were conducted using a Zeego robotic C-arm (20 s, 200°, 496 projections) to image a head phantom undergoing various types of motion: 1) 5° lateral motion; 2) 15° lateral motion; and 3) 5° lateral motion with 10 mm periodic inferior-superior motion. Images were reconstructed using a penalized likelihood (PL) objective function, and structural similarity (SSIM) was measured for axial slices of the reconstructed images. A motion-free image was acquired using the same protocol for comparison. Results: There was significant improvement (p < 0.001) in the SSIM of the motion-corrected (MC) images compared to uncorrected images. The SSIM in MC-PL images was >0.99, indicating near identity to the motion-free reference. The point spread function (PSF) measured from a wire in the phantom was restored to that of the reference in each case. Conclusion: The 3D-2D registration method provides a robust framework for mitigation of motion artifacts and is expected to hold for applications in the head, pelvis, and extremities with reasonably constrained operative setup. Further improvement can be achieved by incorporating multiple rigid components and non-rigid deformation within the framework. The method is highly parallelizable and could in principle be run with every

  1. Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy.

    Science.gov (United States)

    Paganelli, Chiara; Lee, Danny; Kipritidis, John; Whelan, Brendan; Greer, Peter B; Baroni, Guido; Riboldi, Marco; Keall, Paul

    2018-02-11

    In-room MRI is a promising image guidance strategy in external beam radiotherapy to acquire volumetric information for moving targets. However, limitations in spatio-temporal resolution led several authors to use 2D orthogonal images for guidance. The aim of this work is to present a method to concurrently compensate for non-rigid tumour motion and provide an approach for 3D reconstruction from 2D orthogonal cine-MRI slices for MRI-guided treatments. Free-breathing sagittal/coronal interleaved 2D cine-MRI were acquired in addition to a pre-treatment 3D volume in two patients. We performed deformable image registration (DIR) between cine-MRI slices and corresponding slices in the pre-treatment 3D volume. Based on an extrapolation of the interleaved 2D motion fields, the 3D motion field was estimated and used to warp the pre-treatment volume. Due to the lack of a ground truth for patients, the method was validated on a digital 4D lung phantom. On the phantom, the 3D reconstruction method was able to compensate for tumour motion and compared favourably to the results of previously adopted strategies. The difference in the 3D motion fields between the phantom and the extrapolated motion was 0.4 ± 0.3 mm for tumour and 0.8 ± 1.5 mm for whole anatomy, demonstrating feasibility of performing a 3D volumetric reconstruction directly from 2D orthogonal cine-MRI slices. Application of the method to patient data confirmed the feasibility of utilizing this method in real world scenarios. Preliminary results on phantom and patient cases confirm the feasibility of the proposed approach in an MRI-guided scenario, especially for non-rigid tumour motion compensation. © 2018 The Royal Australian and New Zealand College of Radiologists.

  2. Intellect: a theoretical framework for personality traits related to intellectual achievements.

    Science.gov (United States)

    Mussel, Patrick

    2013-05-01

    The present article develops a theoretical framework for the structure of personality traits related to intellectual achievements. We postulate a 2-dimensional model, differentiating between 2 processes (Seek and Conquer) and 3 operations (Think, Learn, and Create). The framework was operationalized by a newly developed measure, which was validated based on 2 samples. Subsequently, in 3 studies (overall N = 1,478), the 2-dimensional structure of the Intellect framework was generally supported. Additionally, subdimensions of the Intellect framework specifically predicted conceptually related criteria, including scholastic performance, vocational interest, and leisure activities. Furthermore, results from multidimensional scaling and higher order confirmatory factor analyses show that the framework allows for the incorporation of several constructs that have been proposed on different theoretical backgrounds, such as need for cognition, typical intellectual engagement, curiosity, intrinsic motivation, goal orientation, and openness to ideas. It is concluded that based on the Intellect framework, these constructs, which have been researched separately in the literature, can be meaningfully integrated.

  3. 3D Graphene Functionalized by Covalent Organic Framework Thin Film as Capacitive Electrode in Alkaline Media.

    Science.gov (United States)

    Zha, Zeqi; Xu, Lirong; Wang, Zhikui; Li, Xiaoguang; Pan, Qinmin; Hu, Pingan; Lei, Shengbin

    2015-08-19

    To harness the electroactivity of anthraquinone as an electrode material, a great recent effort have been invested to composite anthraquinone with carbon materials to improve the conductivity. Here we report on a noncovalent way to modify three-dimensional graphene with anthraquinone moieties through on-surface synthesis of two-dimensional covalent organic frameworks. We incorporate 2,6-diamino-anthraquinone moieties into COF through Schiff-base reaction with benzene-1,3,5-tricarbaldehyde. The synthesized COF -graphene composite exhibits large specific capacitance of 31.7 mF/cm(2). Long-term galvanostatic charge/discharge cycling experiments revealed a decrease of capacitance, which was attributed to the loss of COF materials and electrostatic repulsion accumulated during charge-discharge circles which result in the poor electrical conductivity between 2D COF layers.

  4. A Machine Learning Framework for Plan Payment Risk Adjustment.

    Science.gov (United States)

    Rose, Sherri

    2016-12-01

    To introduce cross-validation and a nonparametric machine learning framework for plan payment risk adjustment and then assess whether they have the potential to improve risk adjustment. 2011-2012 Truven MarketScan database. We compare the performance of multiple statistical approaches within a broad machine learning framework for estimation of risk adjustment formulas. Total annual expenditure was predicted using age, sex, geography, inpatient diagnoses, and hierarchical condition category variables. The methods included regression, penalized regression, decision trees, neural networks, and an ensemble super learner, all in concert with screening algorithms that reduce the set of variables considered. The performance of these methods was compared based on cross-validated R 2 . Our results indicate that a simplified risk adjustment formula selected via this nonparametric framework maintains much of the efficiency of a traditional larger formula. The ensemble approach also outperformed classical regression and all other algorithms studied. The implementation of cross-validated machine learning techniques provides novel insight into risk adjustment estimation, possibly allowing for a simplified formula, thereby reducing incentives for increased coding intensity as well as the ability of insurers to "game" the system with aggressive diagnostic upcoding. © Health Research and Educational Trust.

  5. Structural exploration for the refinement of anticancer matrix metalloproteinase-2 inhibitor designing approaches through robust validated multi-QSARs

    Science.gov (United States)

    Adhikari, Nilanjan; Amin, Sk. Abdul; Saha, Achintya; Jha, Tarun

    2018-03-01

    Matrix metalloproteinase-2 (MMP-2) is a promising pharmacological target for designing potential anticancer drugs. MMP-2 plays critical functions in apoptosis by cleaving the DNA repair enzyme namely poly (ADP-ribose) polymerase (PARP). Moreover, MMP-2 expression triggers the vascular endothelial growth factor (VEGF) having a positive influence on tumor size, invasion, and angiogenesis. Therefore, it is an urgent need to develop potential MMP-2 inhibitors without any toxicity but better pharmacokinetic property. In this article, robust validated multi-quantitative structure-activity relationship (QSAR) modeling approaches were attempted on a dataset of 222 MMP-2 inhibitors to explore the important structural and pharmacophoric requirements for higher MMP-2 inhibition. Different validated regression and classification-based QSARs, pharmacophore mapping and 3D-QSAR techniques were performed. These results were challenged and subjected to further validation to explain 24 in house MMP-2 inhibitors to judge the reliability of these models further. All these models were individually validated internally as well as externally and were supported and validated by each other. These results were further justified by molecular docking analysis. Modeling techniques adopted here not only helps to explore the necessary structural and pharmacophoric requirements but also for the overall validation and refinement techniques for designing potential MMP-2 inhibitors.

  6. Framework for Assessing Biogenic CO2 Emissions from ...

    Science.gov (United States)

    This revision of the 2011 report, Accounting Framework for Biogenic CO2 Emissions from Stationary Sources, evaluates biogenic CO2 emissions from stationary sources, including a detailed study of the scientific and technical issues associated with assessing biogenic carbon dioxide emissions from stationary sources. EPA developed the revised report, Framework for Assessing Biogenic CO2 Emissions from Stationary Sources, to present a methodological framework for assessing the extent to which the production, processing, and use of biogenic material at stationary sources for energy production results in a net atmospheric contribution of biogenic CO2 emissions. Biogenic carbon dioxide emissions are defined as CO2 emissions related to the natural carbon cycle, as well as those resulting from the production, harvest, combustion, digestion, decomposition, and processing of biologically-based materials. The EPA is continuing to refine its technical assessment of biogenic CO2 emissions through another round of targeted peer review of the revised study with the EPA Science Advisory Board (SAB). This study was submitted to the SAB's Biogenic Carbon Emissions Panel in February 2015. http://yosemite.epa.gov/sab/sabproduct.nsf/0/3235dac747c16fe985257da90053f252!OpenDocument&TableRow=2.2#2 The revised report will inform efforts by policymakers, academics, and other stakeholders to evaluate the technical aspects related to assessments of biogenic feedstocks used for energy at s

  7. A Bayesian Framework of Uncertainties Integration in 3D Geological Model

    Science.gov (United States)

    Liang, D.; Liu, X.

    2017-12-01

    3D geological model can describe complicated geological phenomena in an intuitive way while its application may be limited by uncertain factors. Great progress has been made over the years, lots of studies decompose the uncertainties of geological model to analyze separately, while ignored the comprehensive impacts of multi-source uncertainties. Great progress has been made over the years, while lots of studies ignored the comprehensive impacts of multi-source uncertainties when analyzed them item by item from each source. To evaluate the synthetical uncertainty, we choose probability distribution to quantify uncertainty, and propose a bayesian framework of uncertainties integration. With this framework, we integrated data errors, spatial randomness, and cognitive information into posterior distribution to evaluate synthetical uncertainty of geological model. Uncertainties propagate and cumulate in modeling process, the gradual integration of multi-source uncertainty is a kind of simulation of the uncertainty propagation. Bayesian inference accomplishes uncertainty updating in modeling process. Maximum entropy principle makes a good effect on estimating prior probability distribution, which ensures the prior probability distribution subjecting to constraints supplied by the given information with minimum prejudice. In the end, we obtained a posterior distribution to evaluate synthetical uncertainty of geological model. This posterior distribution represents the synthetical impact of all the uncertain factors on the spatial structure of geological model. The framework provides a solution to evaluate synthetical impact on geological model of multi-source uncertainties and a thought to study uncertainty propagation mechanism in geological modeling.

  8. The CHT2 Project: Diachronic 3d Reconstruction of Historic Sites

    Science.gov (United States)

    Guidi, G.; Micoli, L.; Gonizzi Barsanti, S.; Malik, U.

    2017-08-01

    Digital modelling archaeological and architectural monuments in their current state and in their presumed past aspect has been recognized not only as a way for explaining to the public the genesis of a historical site, but also as an effective tool for research. The search for historical sources, their proper analysis and interdisciplinary relationship between technological disciplines and the humanities are fundamental for obtaining reliable hypothetical reconstructions. This paper presents an experimental activity defined by the project Cultural Heritage Through Time - CHT2 (http://cht2-project.eu), funded in the framework of the Joint Programming Initiative on Cultural Heritage (JPI-CH) of the European Commission. Its goal is to develop time-varying 3D products, from landscape to architectural scale, deals with the implementation of the methodology on one of the case studies: the late Roman circus of Milan, built in the era when the city was the capital of the Western Roman Empire (286-402 A.D). The work presented here covers one of the cases in which the physical evidences have now been almost entirely disappeared. The diachronic reconstruction is based on a proper mix of quantitative data originated by 3D surveys at present time, and historical sources like ancient maps, drawings, archaeological reports, archaeological restrictions decrees and old photographs. Such heterogeneous sources have been first georeferenced and then properly integrated according to the methodology defined in the framework of the CHT2 project, to hypothesize a reliable reconstruction of the area in different historical periods.

  9. V&V framework

    Energy Technology Data Exchange (ETDEWEB)

    Hills, Richard G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Maniaci, David Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Naughton, Jonathan W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    A Verification and Validation (V&V) framework is presented for the development and execution of coordinated modeling and experimental program s to assess the predictive capability of computational models of complex systems through focused, well structured, and formal processes.The elements of the framework are based on established V&V methodology developed by various organizations including the Department of Energy, National Aeronautics and Space Administration, the American Institute of Aeronautics and Astronautics, and the American Society of Mechanical Engineers. Four main topics are addressed: 1) Program planning based on expert elicitation of the modeling physics requirements, 2) experimental design for model assessment, 3) uncertainty quantification for experimental observations and computational model simulations, and 4) assessment of the model predictive capability. The audience for this document includes program planners, modelers, experimentalist, V &V specialist, and customers of the modeling results.

  10. Sensor Based Framework for Secure Multimedia Communication in VANET

    Science.gov (United States)

    Rahim, Aneel; Khan, Zeeshan Shafi; Bin Muhaya, Fahad T.; Sher, Muhammad; Kim, Tai-Hoon

    2010-01-01

    Secure multimedia communication enhances the safety of passengers by providing visual pictures of accidents and danger situations. In this paper we proposed a framework for secure multimedia communication in Vehicular Ad-Hoc Networks (VANETs). Our proposed framework is mainly divided into four components: redundant information, priority assignment, malicious data verification and malicious node verification. The proposed scheme jhas been validated with the help of the NS-2 network simulator and the Evalvid tool. PMID:22163462

  11. Infrared spectra and tunneling dynamics of the N2-D2O and OC-D2O complexes in the v2 bend region of D2O.

    Science.gov (United States)

    Zhu, Yu; Zheng, Rui; Li, Song; Yang, Yu; Duan, Chuanxi

    2013-12-07

    The rovibrational spectra of the N2-D2O and OC-D2O complexes in the v2 bend region of D2O have been measured in a supersonic slit jet expansion using a rapid-scan tunable diode laser spectrometer. Both a-type and b-type transitions were observed for these two complexes. All transitions are doubled, due to the heavy water tunneling within the complexes. Assuming the tunneling splittings are the same in K(a) = 0 and K(a) = 1, the band origins, all three rotational and several distortion constants of each tunneling state were determined for N2-D2O in the ground and excited vibrational states, and for OC-D2O in the excited vibrational state, respectively. The averaged band origin of OC-D2O is blueshifted by 2.241 cm(-1) from that of the v2 band of the D2O monomer, compared with 1.247 cm(-1) for N2-D2O. The tunneling splitting of N2-D2O in the ground state is 0.16359(28) cm(-1), which is about five times that of OC-D2O. The tunneling splittings decrease by about 26% for N2-D2O and 23% for OC-D2O, respectively, upon excitation of the D2O bending vibration, indicating an increase of the tunneling barrier in the excited vibrational state. The tunneling splittings are found to have a strong dependence on intramolecular vibrational excitation as well as a weak dependence on quantum number K(a).

  12. MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Ceberg, S. [Lund University (Sweden)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  13. MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden

    International Nuclear Information System (INIS)

    Ceberg, S.

    2016-01-01

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  14. An Upper Bound on the Entropy of Constrained 2d Fields

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Justesen, Jørn

    1998-01-01

    An upper bound on the entropy of constrained 2D fields is presented. The constraints have to be symmetric in (at least) one of the two directions. The bound generalizes (in a weaker form) the bound of Calkin and Wilf (see SIAM Journal of Discrete Mathematics, vol.11, p.54-60, 1998) which is valid...

  15. DynEarthSol2D: An efficient unstructured finite element method to study long-term tectonic deformation

    KAUST Repository

    Choi, E.; Tan, E.; Lavier, L. L.; Calo, Victor M.

    2013-01-01

    Many tectonic problems require to treat the lithosphere as a compressible elastic material, which can also flow viscously or break in a brittle fashion depending on the stress level applied and the temperature conditions. We present a flexible methodology to address the resulting complex material response, which imposes severe challenges on the discretization and rheological models used. This robust, adaptive, two-dimensional, finite element method solves the momentum balance and the heat equation in Lagrangian form using unstructured meshes. An implementation of this methodology is released to the public with the publication of this paper and is named DynEarthSol2D (available at http://bitbucket.org/tan2/dynearthsol2). The solver uses contingent mesh adaptivity in places where shear strain is focused (localization) and a conservative mapping assisted by marker particles to preserve phase and facies boundaries during remeshing. We detail the solver and verify it in a number of benchmark problems against analytic and numerical solutions from the literature. These results allow us to verify and validate our software framework and show its improved performance by an order of magnitude compared against an earlier implementation of the Fast Lagrangian Analysis of Continua algorithm.

  16. DynEarthSol2D: An efficient unstructured finite element method to study long-term tectonic deformation

    KAUST Repository

    Choi, E.

    2013-05-01

    Many tectonic problems require to treat the lithosphere as a compressible elastic material, which can also flow viscously or break in a brittle fashion depending on the stress level applied and the temperature conditions. We present a flexible methodology to address the resulting complex material response, which imposes severe challenges on the discretization and rheological models used. This robust, adaptive, two-dimensional, finite element method solves the momentum balance and the heat equation in Lagrangian form using unstructured meshes. An implementation of this methodology is released to the public with the publication of this paper and is named DynEarthSol2D (available at http://bitbucket.org/tan2/dynearthsol2). The solver uses contingent mesh adaptivity in places where shear strain is focused (localization) and a conservative mapping assisted by marker particles to preserve phase and facies boundaries during remeshing. We detail the solver and verify it in a number of benchmark problems against analytic and numerical solutions from the literature. These results allow us to verify and validate our software framework and show its improved performance by an order of magnitude compared against an earlier implementation of the Fast Lagrangian Analysis of Continua algorithm.

  17. Distributed 3D Source Localization from 2D DOA Measurements Using Multiple Linear Arrays

    Directory of Open Access Journals (Sweden)

    Antonio Canclini

    2017-01-01

    Full Text Available This manuscript addresses the problem of 3D source localization from direction of arrivals (DOAs in wireless acoustic sensor networks. In this context, multiple sensors measure the DOA of the source, and a central node combines the measurements to yield the source location estimate. Traditional approaches require 3D DOA measurements; that is, each sensor estimates the azimuth and elevation of the source by means of a microphone array, typically in a planar or spherical configuration. The proposed methodology aims at reducing the hardware and computational costs by combining measurements related to 2D DOAs estimated from linear arrays arbitrarily displaced in the 3D space. Each sensor measures the DOA in the plane containing the array and the source. Measurements are then translated into an equivalent planar geometry, in which a set of coplanar equivalent arrays observe the source preserving the original DOAs. This formulation is exploited to define a cost function, whose minimization leads to the source location estimation. An extensive simulation campaign validates the proposed approach and compares its accuracy with state-of-the-art methodologies.

  18. On the impact of D2D traffic offloading on energy efficiency in green LTE-A HetNets

    KAUST Repository

    Yaacoub, Elias E.

    2014-08-11

    In this paper, the interplay between cooperative device-to-device (D2D) communications and green cellular communications in the long term evolution (LTE) and LTE-advanced (LTE-A) cellular systems is investigated. An efficient approach for grouping mobile terminals (MTs) into cooperative clusters is described. In each cluster, MTs cooperate via D2D communications to share content of common interest. In addition, an energy-efficient approach for putting base stations in sleep mode in an LTE-A heterogeneous network is presented. Finally, both methods are combined in order to ensure green communications for both the users\\' MTs and the operator\\'s base stations. The presented techniques are investigated in the framework of orthogonal frequency division multiple access-based state-of-the-art LTE cellular networks, while taking resource allocation and intercell interference into account. Results show that the proposed approach leads to energy savings for both the operator and the MTs, while leading to enhanced quality of service for mobile users. Copyright © 2014 John Wiley & Sons, Ltd.

  19. A framework for m-health service development and success evaluation.

    Science.gov (United States)

    Sadegh, S Saeedeh; Khakshour Saadat, Parisa; Sepehri, Mohammad Mehdi; Assadi, Vahid

    2018-04-01

    The emergence of mobile technology has influenced many service industries including health care. Mobile health (m-Health) applications have been used widely, and many services have been developed that have changed delivery systems and have improved effectiveness of health care services. Stakeholders of m-Health services have various resources and rights that lends to a complexity in service delivery. In addition, abundance of different m-Health services makes it difficult to choose an appropriate service for these stakeholders that include customers, patients, users or even providers. Moreover, a comprehensive framework is not yet provided in the literature that would help manage and evaluate m-health services, considering various stakeholder's benefits. In this paper, a comprehensive literature review has been done on famous frameworks and models in the field of Information Technology and electronic health with the aim of finding different aspects of developing and managing m-health services. Using the results of literature review and conducting a stakeholder analysis, we have proposed an m-health evaluation framework which evaluates the success of a given m-health service through a three-stage life cycle: (1) Service Requirement Analysis, (2) Service Development, and (3) Service Delivery. Key factors of m-health evaluation in each step are introduced in the proposed framework considering m-health key stakeholder's benefits. The proposed framework is validated via expert interviews, and key factors in each evaluation step is validated using PLS model. Results show that path coefficients are higher than their threshold which supports the validity of proposed framework. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Robust ∞ Filtering of 2D Roesser Discrete Systems: A Polynomial Approach

    Directory of Open Access Journals (Sweden)

    Chakir El-Kasri

    2012-01-01

    procedure for generating conditions for the existence of a 2D discrete filter such that, for all admissible uncertainties, the error system is asymptotically stable, and the ∞ norm of the transfer function from the noise signal to the estimation error is below a prespecified level. These conditions are expressed as parameter-dependent linear matrix inequalities. Using homogeneous polynomially parameter-dependent filters of arbitrary degree on the uncertain parameters, the proposed method extends previous results in the quadratic framework and the linearly parameter-dependent framework, thus reducing its conservatism. Performance of the proposed method, in comparison with that of existing methods, is illustrated by two examples.

  1. GeoFramework: A Modeling Framework for Solid Earth Geophysics

    Science.gov (United States)

    Gurnis, M.; Aivazis, M.; Tromp, J.; Tan, E.; Thoutireddy, P.; Liu, Q.; Choi, E.; Dicaprio, C.; Chen, M.; Simons, M.; Quenette, S.; Appelbe, B.; Aagaard, B.; Williams, C.; Lavier, L.; Moresi, L.; Law, H.

    2003-12-01

    As data sets in geophysics become larger and of greater relevance to other earth science disciplines, and as earth science becomes more interdisciplinary in general, modeling tools are being driven in new directions. There is now a greater need to link modeling codes to one another, link modeling codes to multiple datasets, and to make modeling software available to non modeling specialists. Coupled with rapid progress in computer hardware (including the computational speed afforded by massively parallel computers), progress in numerical algorithms, and the introduction of software frameworks, these lofty goals of merging software in geophysics are now possible. The GeoFramework project, a collaboration between computer scientists and geoscientists, is a response to these needs and opportunities. GeoFramework is based on and extends Pyre, a Python-based modeling framework, recently developed to link solid (Lagrangian) and fluid (Eulerian) models, as well as mesh generators, visualization packages, and databases, with one another for engineering applications. The utility and generality of Pyre as a general purpose framework in science is now being recognized. Besides its use in engineering and geophysics, it is also being used in particle physics and astronomy. Geology and geophysics impose their own unique requirements on software frameworks which are not generally available in existing frameworks and so there is a need for research in this area. One of the special requirements is the way Lagrangian and Eulerian codes will need to be linked in time and space within a plate tectonics context. GeoFramework has grown beyond its initial goal of linking a limited number of exiting codes together. The following codes are now being reengineered within the context of Pyre: Tecton, 3-D FE Visco-elastic code for lithospheric relaxation; CitComS, a code for spherical mantle convection; SpecFEM3D, a SEM code for global and regional seismic waves; eqsim, a FE code for dynamic

  2. Comparison of 2D and 3D magnetic field analysis of single-phase shaded pole induction motors

    Directory of Open Access Journals (Sweden)

    Adem Dalcali

    2016-03-01

    Full Text Available There has always been doubt on the accuracy of 2D analysis of small electric machines. To investigate the validity of this doubt, in this present work a small uni-coil shaded-pole induction motor is analyzed in 2D and 3D and the results are compared. In order to maintain the paper size as compact, the analysis is limited to the air-gap flux density distribution, variation of the main winding inductance against current and the force acting on the rotor body; which are the important components of the motor performance. It is found that although 3D analysis consumes several times more computing time and storage space, improvement achieved in performance by use of 3D analysis is not very significant. % rms difference between the two cases is obtained as 0.76% for the main winding inductance and 0.59% for the force acting on the rotor body. Also the air-gap flux density distribution obtained from the two types of analysis is found to be very close to each other. Therefore it is concluded that despite more computing time, more storage requirements and more human effort in the case of 3D analysis, the degree of improvement is not proportionally rewarding, and hence, 2D analysis is sufficient for the analysis of small machines.

  3. Fast multi-core based multimodal registration of 2D cross-sections and 3D datasets

    Directory of Open Access Journals (Sweden)

    Pielot Rainer

    2010-01-01

    Full Text Available Abstract Background Solving bioinformatics tasks often requires extensive computational power. Recent trends in processor architecture combine multiple cores into a single chip to improve overall performance. The Cell Broadband Engine (CBE, a heterogeneous multi-core processor, provides power-efficient and cost-effective high-performance computing. One application area is image analysis and visualisation, in particular registration of 2D cross-sections into 3D image datasets. Such techniques can be used to put different image modalities into spatial correspondence, for example, 2D images of histological cuts into morphological 3D frameworks. Results We evaluate the CBE-driven PlayStation 3 as a high performance, cost-effective computing platform by adapting a multimodal alignment procedure to several characteristic hardware properties. The optimisations are based on partitioning, vectorisation, branch reducing and loop unrolling techniques with special attention to 32-bit multiplies and limited local storage on the computing units. We show how a typical image analysis and visualisation problem, the multimodal registration of 2D cross-sections and 3D datasets, benefits from the multi-core based implementation of the alignment algorithm. We discuss several CBE-based optimisation methods and compare our results to standard solutions. More information and the source code are available from http://cbe.ipk-gatersleben.de. Conclusions The results demonstrate that the CBE processor in a PlayStation 3 accelerates computational intensive multimodal registration, which is of great importance in biological/medical image processing. The PlayStation 3 as a low cost CBE-based platform offers an efficient option to conventional hardware to solve computational problems in image processing and bioinformatics.

  4. Validation of multisource electronic health record data: an application to blood transfusion data.

    Science.gov (United States)

    Hoeven, Loan R van; Bruijne, Martine C de; Kemper, Peter F; Koopman, Maria M W; Rondeel, Jan M M; Leyte, Anja; Koffijberg, Hendrik; Janssen, Mart P; Roes, Kit C B

    2017-07-14

    Although data from electronic health records (EHR) are often used for research purposes, systematic validation of these data prior to their use is not standard practice. Existing validation frameworks discuss validity concepts without translating these into practical implementation steps or addressing the potential influence of linking multiple sources. Therefore we developed a practical approach for validating routinely collected data from multiple sources and to apply it to a blood transfusion data warehouse to evaluate the usability in practice. The approach consists of identifying existing validation frameworks for EHR data or linked data, selecting validity concepts from these frameworks and establishing quantifiable validity outcomes for each concept. The approach distinguishes external validation concepts (e.g. concordance with external reports, previous literature and expert feedback) and internal consistency concepts which use expected associations within the dataset itself (e.g. completeness, uniformity and plausibility). In an example case, the selected concepts were applied to a transfusion dataset and specified in more detail. Application of the approach to a transfusion dataset resulted in a structured overview of data validity aspects. This allowed improvement of these aspects through further processing of the data and in some cases adjustment of the data extraction. For example, the proportion of transfused products that could not be linked to the corresponding issued products initially was 2.2% but could be improved by adjusting data extraction criteria to 0.17%. This stepwise approach for validating linked multisource data provides a basis for evaluating data quality and enhancing interpretation. When the process of data validation is adopted more broadly, this contributes to increased transparency and greater reliability of research based on routinely collected electronic health records.

  5. A collaborative computing framework of cloud network and WBSN applied to fall detection and 3-D motion reconstruction.

    Science.gov (United States)

    Lai, Chin-Feng; Chen, Min; Pan, Jeng-Shyang; Youn, Chan-Hyun; Chao, Han-Chieh

    2014-03-01

    As cloud computing and wireless body sensor network technologies become gradually developed, ubiquitous healthcare services prevent accidents instantly and effectively, as well as provides relevant information to reduce related processing time and cost. This study proposes a co-processing intermediary framework integrated cloud and wireless body sensor networks, which is mainly applied to fall detection and 3-D motion reconstruction. In this study, the main focuses includes distributed computing and resource allocation of processing sensing data over the computing architecture, network conditions and performance evaluation. Through this framework, the transmissions and computing time of sensing data are reduced to enhance overall performance for the services of fall events detection and 3-D motion reconstruction.

  6. Zend framework 2 cookbook

    CERN Document Server

    Callaars, Josephus

    2013-01-01

    This book is written in a practical, cookbook style with numerous examples and recipes. This style allows you to go both directly to your topic of interest or follow topics throughout a chapter to gain an in-depth knowledge of certain areas.'Zend Framework 2 Cookbook"" is for PHP developers who are fairly advanced in programming in PHP. It will also be useful for developers who have a keen interest in expanding their knowledge outside the boundaries of simply scripting pages together. As unit testing and MVC will be discussed, it is beneficial for the reader to know what these technologies are

  7. Accurate Angle Estimator for High-Frame-rate 2-D Vector Flow Imaging

    DEFF Research Database (Denmark)

    Villagómez Hoyos, Carlos Armando; Stuart, Matthias Bo; Lindskov Hansen, Kristoffer

    2016-01-01

    This paper presents a novel approach for estimating 2-D flow angles using a high-frame-rate ultrasound method. The angle estimator features high accuracy and low standard deviation (SD) over the full 360° range. The method is validated on Field II simulations and phantom measurements using...

  8. Characterization of separability and entanglement in (2xD)- and (3xD)-dimensional systems by single-qubit and single-qutrit unitary transformations

    International Nuclear Information System (INIS)

    Giampaolo, Salvatore M.; Illuminati, Fabrizio

    2007-01-01

    We investigate the geometric characterization of pure state bipartite entanglement of (2xD)- and (3xD)-dimensional composite quantum systems. To this aim, we analyze the relationship between states and their images under the action of particular classes of local unitary operations. We find that invariance of states under the action of single-qubit and single-qutrit transformations is a necessary and sufficient condition for separability. We demonstrate that in the (2xD)-dimensional case the von Neumann entropy of entanglement is a monotonic function of the minimum squared Euclidean distance between states and their images over the set of single qubit unitary transformations. Moreover, both in the (2xD)- and in the (3xD)-dimensional cases the minimum squared Euclidean distance exactly coincides with the linear entropy [and thus as well with the tangle measure of entanglement in the (2xD)-dimensional case]. These results provide a geometric characterization of entanglement measures originally established in informational frameworks. Consequences and applications of the formalism to quantum critical phenomena in spin systems are discussed

  9. Public administration and R&D localisation by pharmaceutical and biotech companies: a theoretical framework and the Italian case-study.

    Science.gov (United States)

    Jommi, Claudio; Paruzzolo, Silvia

    2007-04-01

    This article has two objectives. It firstly provides a general framework for variables that influence R&D (Research and Development) localisation by pharmaceutical and biotech companies. The analysis of R&D localization includes both in-house R&D and contracted R&D. Following a systematic literature search, these variables were classified into four distinct categories: regulatory environment, institutional framework, national systems of innovation and local development and specialisation. The authors highlight that some of these factors directly depend on the action of public administrations (e.g., patent protection, price regulation, public investments in research, and incentives to private companies); others are indirectly influenced by public policies (e.g., GDP growth rate, infrastructures). This theoretical framework was used to analyse the Italian case-study. Pros and cons of the Italian context were investigated from the point of view of multinational pharmaceutical companies and the Italian Association of Biotech Companies. Interviews were chosen as the most appropriate data gathering technique given the exploratory nature of the study of the Italian context. The paper is divided into five parts. A brief introduction provides figures showing that Europe has been loosing positions compared with other Continents and the same has occurred in Italy compared with other EU countries. The second one illustrates the methodology. The third one is focused on variables affecting R&D localisation. In the fourth section the Italian case-study is discussed. Theoretical and empirical findings are summarised and discussed in the conclusions.

  10. 5-Isopropylidene-1,3-dithiolo[4,5-d][1,3]dithiole-2-thione

    Directory of Open Access Journals (Sweden)

    Yoshiro Yamashita

    2009-05-01

    Full Text Available The title compound, C7H6S5, contains a 5-ylidene-1,3-dithiolo[4,5-d][1,3]dithiole-2-thione framework, which is an important synthetic precursor of multi-dimensional organic superconductors and conductors. The molecular framework is planar with an r.m.s. deviation of 0.012 Å for the non-H atoms. In the crystal structure, molecules are linked by short intermolecular S...S interactions [3.501 (5 and 3.581 (4 Å], constructing a zigzag molecular tape network along the c axis.

  11. Comparison of 2D and 3D modeled tumor motion estimation/prediction for dynamic tumor tracking during arc radiotherapy

    Science.gov (United States)

    Liu, Wu; Ma, Xiangyu; Yan, Huagang; Chen, Zhe; Nath, Ravinder; Li, Haiyun

    2017-05-01

    Many real-time imaging techniques have been developed to localize a target in 3D space or in a 2D beam’s eye view (BEV) plane for intrafraction motion tracking in radiation therapy. With tracking system latency, the 3D-modeled method is expected to be more accurate even in terms of 2D BEV tracking error. No quantitative analysis, however, has been reported. In this study, we simulated co-planar arc deliveries using respiratory motion data acquired from 42 patients to quantitatively compare the accuracy between 2D BEV and 3D-modeled tracking in arc therapy and to determine whether 3D information is needed for motion tracking. We used our previously developed low kV dose adaptive MV-kV imaging and motion compensation framework as a representative of 3D-modeled methods. It optimizes the balance between additional kV imaging dose and 3D tracking accuracy and solves the MLC blockage issue. With simulated Gaussian marker detection errors (zero mean and 0.39 mm standard deviation) and ~155/310/460 ms tracking system latencies, the mean percentage of time that the target moved  >2 mm from the predicted 2D BEV position are 1.1%/4.0%/7.8% and 1.3%/5.8%/11.6% for the 3D-modeled and 2D-only tracking, respectively. The corresponding average BEV RMS errors are 0.67/0.90/1.13 mm and 0.79/1.10/1.37 mm. Compared to the 2D method, the 3D method reduced the average RMS unresolved motion along the beam direction from ~3 mm to ~1 mm, resulting in on average only  <1% dosimetric advantage in the depth direction. Only for a small fraction of the patients, when tracking latency is long, the 3D-modeled method showed significant improvement of BEV tracking accuracy, indicating potential dosimetric advantage. However, if the tracking latency is short (~150 ms or less), those improvements are limited. Therefore, 2D BEV tracking has sufficient targeting accuracy for most clinical cases. The 3D technique is, however, still important in solving the MLC blockage problem

  12. A Framework for Developing the Structure of Public Health Economic Models.

    Science.gov (United States)

    Squires, Hazel; Chilcott, James; Akehurst, Ronald; Burr, Jennifer; Kelly, Michael P

    2016-01-01

    A conceptual modeling framework is a methodology that assists modelers through the process of developing a model structure. Public health interventions tend to operate in dynamically complex systems. Modeling public health interventions requires broader considerations than clinical ones. Inappropriately simple models may lead to poor validity and credibility, resulting in suboptimal allocation of resources. This article presents the first conceptual modeling framework for public health economic evaluation. The framework presented here was informed by literature reviews of the key challenges in public health economic modeling and existing conceptual modeling frameworks; qualitative research to understand the experiences of modelers when developing public health economic models; and piloting a draft version of the framework. The conceptual modeling framework comprises four key principles of good practice and a proposed methodology. The key principles are that 1) a systems approach to modeling should be taken; 2) a documented understanding of the problem is imperative before and alongside developing and justifying the model structure; 3) strong communication with stakeholders and members of the team throughout model development is essential; and 4) a systematic consideration of the determinants of health is central to identifying the key impacts of public health interventions. The methodology consists of four phases: phase A, aligning the framework with the decision-making process; phase B, identifying relevant stakeholders; phase C, understanding the problem; and phase D, developing and justifying the model structure. Key areas for further research involve evaluation of the framework in diverse case studies and the development of methods for modeling individual and social behavior. This approach could improve the quality of Public Health economic models, supporting efficient allocation of scarce resources. Copyright © 2016 International Society for Pharmacoeconomics

  13. Time resolved spectroscopic investigation of SiD2 + D2: kinetic study

    Science.gov (United States)

    Al-Rubaiey, Najem A.; Walsh, Robin

    2017-03-01

    Silylenes (silanediyls) have made an important impact on organosilicon chemistry even if it is of more recent foundation than carbenes in organic chemistry and much less complete. These species are highly reactive intermediates. They play a central role in the chemical vapour deposition (CVD) of various silicon-containing thin films which have a technological importance in microelectronics as well as in the dry etching processes of silicon wafers. Spectroscopic methods have been developed to observe these species, a necessary pre-requisite to their direct monitoring. In this work, deuterated phenylsilane precursor, PhSiD3 was chosen for SiD2 because its analogue phenylsilane, PhSiH3 proved to be a good precursor for SiH2 and the high quality decay signals observed revealed that SiD2 be readily detected from PhSiD3 and that if other decomposition pathways (e.g. PhSiD + D2) are occurring, they do not effect measurements of the rate constants for SiD2. The absorption spectrum of SiD2 formed from the flash photolysis of a mixture of PhSiD3 and SF6 at 193nm were found in the region 17384-17391 cm-1 with strong band at 17387.07 cm-1. This single rotational line of pQ1 was chosen to monitor SiD2 removal. Time-resolved studies of SiD2 have been carried out to obtain rate constants for its bimolecular reactions with D2. The reactions were studied over the pressure range 5-100 Torr (in SF6 bath gas) at four temperatures in the range 298-498K. Single decay from 10 photolysis laser shots were averaged and found to give reasonable first-order kinetics fits. Second order kinetics were obtained by pressure dependence of the pseudo first order decay constants and substance D2 pressures within experimental error. The reaction was found to be weakly pressure dependent at all temperatures, consistent with a third-body mediated association process. In addition, SiH2+ H2 reaction is approximately ca. 60% faster than SiD2+D2 reaction. Theoretical extrapolations (using Lindemann

  14. Time resolved spectroscopic investigation of SiD2 + D2: kinetic study

    Directory of Open Access Journals (Sweden)

    Al-Rubaiey Najem A.

    2017-01-01

    Full Text Available Silylenes (silanediyls have made an important impact on organosilicon chemistry even if it is of more recent foundation than carbenes in organic chemistry and much less complete. These species are highly reactive intermediates. They play a central role in the chemical vapour deposition (CVD of various silicon-containing thin films which have a technological importance in microelectronics as well as in the dry etching processes of silicon wafers. Spectroscopic methods have been developed to observe these species, a necessary pre-requisite to their direct monitoring. In this work, deuterated phenylsilane precursor, PhSiD3 was chosen for SiD2 because its analogue phenylsilane, PhSiH3 proved to be a good precursor for SiH2 and the high quality decay signals observed revealed that SiD2 be readily detected from PhSiD3 and that if other decomposition pathways (e.g. PhSiD + D2 are occurring, they do not effect measurements of the rate constants for SiD2. The absorption spectrum of SiD2 formed from the flash photolysis of a mixture of PhSiD3 and SF6 at 193nm were found in the region 17384-17391 cm-1 with strong band at 17387.07 cm-1. This single rotational line of pQ1 was chosen to monitor SiD2 removal. Time-resolved studies of SiD2 have been carried out to obtain rate constants for its bimolecular reactions with D2. The reactions were studied over the pressure range 5-100 Torr (in SF6 bath gas at four temperatures in the range 298-498K. Single decay from 10 photolysis laser shots were averaged and found to give reasonable first-order kinetics fits. Second order kinetics were obtained by pressure dependence of the pseudo first order decay constants and substance D2 pressures within experimental error. The reaction was found to be weakly pressure dependent at all temperatures, consistent with a third-body mediated association process. In addition, SiH2+ H2 reaction is approximately ca. 60% faster than SiD2+D2 reaction. Theoretical extrapolations (using

  15. Un procédé de validation des métamodèles par les métadonnées

    OpenAIRE

    Plantec , Alain; Ribaud , Vincent

    2005-01-01

    International audience; La norme STEP a pour objet de standardiser des modèles de données par métier. Ce standard a développé un procédé de validation de la conformité des modèles dans lequel l'instanciation est un composant essentiel : un modèle est valide si un ensemble d'instances conformes au modèle est jugé sémantiquement correct par un expert du domaine. Appliqué à la métamodélisation, cette approche permet de construire et de valider les métamodèles par ranements successifs. Cette méth...

  16. Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI

    International Nuclear Information System (INIS)

    Meckel, Stephan; Leitner, Lorenz; Schubert, Tilman; Bonati, Leo H.; Lyrer, Philippe; Santini, Francesco; Stalder, Aurelien F.; Markl, Michael; Wetzel, Stephan G.

    2013-01-01

    4D phase contrast MR imaging (4D PC MRI) has been introduced for spatiotemporal evaluation of intracranial hemodynamics in various cerebrovascular diseases. However, it still lacks validation with standards of reference. Our goal was to compare blood flow quantification derived from 4D PC MRI with transcranial ultrasound and 2D PC MRI. Velocity measurements within large intracranial arteries [internal carotid artery (ICA), basilar artery (BA), and middle cerebral artery (MCA)] were obtained in 20 young healthy volunteers with 4D and 2D PC MRI, transcranial Doppler sonography (TCD), and transcranial color-coded duplex sonography (TCCD). Maximum velocities at peak systole (PSV) and end diastole (EDV) were compared using regression analysis and Bland-Altman plots. Correlation of 4D PC MRI measured velocities was higher in comparison with TCD (r = 0.49-0.66) than with TCCD (0.35-0.44) and 2D PC MRI (0.52-0.60). In mid-BA and ICA C7 segment, a significant correlation was found with TCD (0.68-0.81 and 0.65-0.71, respectively). No significant correlation was found in carotid siphon. On average over all volunteers, PSVs and EDVs in MCA were minimally underestimated compared with TCD/TCCD. Minimal overestimation of velocities was found compared to TCD in mid-BA and ICA C7 segment. 4D PC MRI appears as valid alternative for intracranial velocity measurement consistent with previous reference standards, foremost with TCD. Spatiotemporal averaging effects might contribute to vessel size-dependent mild underestimation of velocities in smaller (MCA), and overestimation in larger-sized (BA and ICA) arteries, respectively. Complete spatiotemporal flow analysis may be advantageous in anatomically complex regions (e.g. carotid siphon) relative to restrictions of ultrasound techniques. (orig.)

  17. Cocaine-induced adaptation of dopamine D2S, but not D2L autoreceptors.

    Science.gov (United States)

    Robinson, Brooks G; Condon, Alec F; Radl, Daniela; Borrelli, Emiliana; Williams, John T; Neve, Kim A

    2017-11-20

    The dopamine D2 receptor has two splice variants, D2S (Short) and D2L (Long). In dopamine neurons, both variants can act as autoreceptors to regulate neuronal excitability and dopamine release, but the roles of each variant are incompletely characterized. In a previous study we used viral receptor expression in D2 receptor knockout mice to show distinct effects of calcium signaling on D2S and D2L autoreceptor function (Gantz et al., 2015). However, the cocaine-induced plasticity of D2 receptor desensitization observed in wild type mice was not recapitulated with this method of receptor expression. Here we use mice with genetic knockouts of either the D2S or D2L variant to investigate cocaine-induced plasticity in D2 receptor signaling. Following a single in vivo cocaine exposure, the desensitization of D2 receptors from neurons expressing only the D2S variant was reduced. This did not occur in D2L-expressing neurons, indicating differential drug-induced plasticity between the variants.

  18. Further Validation of the IDAS: Evidence of Convergent, Discriminant, Criterion, and Incremental Validity

    Science.gov (United States)

    Watson, David; O'Hara, Michael W.; Chmielewski, Michael; McDade-Montez, Elizabeth A.; Koffel, Erin; Naragon, Kristin; Stuart, Scott

    2008-01-01

    The authors explicated the validity of the Inventory of Depression and Anxiety Symptoms (IDAS; D. Watson et al., 2007) in 2 samples (306 college students and 605 psychiatric patients). The IDAS scales showed strong convergent validity in relation to parallel interview-based scores on the Clinician Rating version of the IDAS; the mean convergent…

  19. Fully-coupled hydro-mechanical modelling of the D-holes and validation drift inflow

    International Nuclear Information System (INIS)

    Monsen, K.; Barton, N.; Makurat, A.

    1992-02-01

    This report presents the results from fully-coupled hydro-mechanical modelling of the D-hole and drift inflows. Joints represented in Harwells stochastically generated 8m x 8m x 8m cubes were used to select two possible joint geometries for two-dimensional rock mechanics simulations of the 2.8 x 2.2m validation drift, and the rock mass response to its excavation. The joints intersecting the four end faces of these cubes were set up in distinct element UDEC-BB models and loaded with boundary stresses of 10 MPa vertically and 14 MPa horizontally. In numerical models 5 and 8, which were run first as mechanical response (M) models (TR 91-05), full H-M coupling was performed, with calculations of inflow. In general, response to excavation was a little stronger than in hte un-coupled mechanical response (M) modelling. In the D-hole simulations, however, channel development int he disturbed zone could not occur due to less displacement taking place in the rock mass. For this reason, the stress levels were also generally much more moderate, preventing the joints from closing as much as in the drift simulations. Consequently, the D-hole model had a much better radial connectivity. It was possible to observe that the radial inflow to the D-holes was significantly higher than the flow into the drift models. However, due to the extremely small joint apertures involved (<1μm), time steps and calculation times were very slow in the H-M models, and although mechanical behaviour appeared to have reached equilibrium, there was evidence of continued transients in some of the flow regions. The drift excavation caused nearly total closing of critical joints due to local normal stress inceases. Near-blockage of fluid transportation routes was demonstrated. (au)

  20. Sensor Based Framework for Secure Multimedia Communication in VANET

    Directory of Open Access Journals (Sweden)

    Tai-Hoon Kim

    2010-11-01

    Full Text Available Secure multimedia communication enhances the safety of passengers by providing visual pictures of accidents and danger situations. In this paper we proposed a framework for secure multimedia communication in Vehicular Ad-Hoc Networks (VANETs. Our proposed framework is mainly divided into four components: redundant information, priority assignment, malicious data verification and malicious node verification. The proposed scheme jhas been validated with the help of the NS-2 network simulator and the Evalvid tool.

  1. 4,2':6',4"- and 3,2':6',3"-Terpyridines: The Conflict between Well-Defined Vectorial Properties and Serendipity in the Assembly of 1D-, 2D- and 3D-Architectures.

    Science.gov (United States)

    Klein, Y Maximilian; Prescimone, Alessandro; Constable, Edwin C; Housecroft, Catherine E

    2017-06-30

    A comparative investigation of the coordination assemblies formed between Co(NCS)₂ and two monotopic 4,2':6',4''-terpyridine (4,2':6',4"-tpy) ligands or two related ditopic ligands is reported. Crystals were grown by layering MeOH solutions of Co(NCS)₂ over a CHCl₃ or 1,2-C₆H₄Cl₂ solution of the respective ligand at room temperature. With 4'-(2-methylpyrimidin-5-yl)-4,2':6',4"-terpyridine ( 6 ), the 1D-coordination polymer {[Co₂(NCS)₄(MeOH)₄( 6 )₂]∙2MeOH∙8H₂O} n assembles with 6 coordinating only through the outer N-donors of the 4,2':6',4"-tpy unit; coordination by the MeOH solvent blocks two cobalt coordination sites preventing propagation in a higher-dimensional network. A combination of Co(NCS)₂ and 1-(4,2':6',4"-terpyridin-4'-yl)ferrocene ( 7 ) leads to {[Co(NCS)₂( 7 )₂]∙4CHCl₃} n which contains a (4,4) net; the 2D-sheets associate through π-stacking interactions between ferrocenyl and pyridyl units. A 3D-framework is achieved through use of the ditopic ligand 1,4-bis( n propoxy)-2,5-bis(4,2':6',4"-terpyridin-4'-yl)benzene ( 8 ) which acts as a 4-connecting node in {[Co(NCS)₂( 8 )₂] . 2C₆H₄Cl₂} n ; the combination of metal and ligand planar 4-connecting nodes results in a {6⁵.8} cds net. For a comparison with the coordinating abilities of the previously reported 1,4-bis( n octoxy)-2,5-bis(4,2':6',4"-terpyridin-4'-yl)benzene ( 3 ), a more flexible analogue 9 was prepared. {[Co(NCS)₂( 9 )]∙2CHCl₃} n contains a (4,4) net defined by both metal and ligand planar 4-connecting nodes. The n octoxy tails of 9 protrude from each side of the (4,4) net and thread through adjacent sheets; the arene-attached n octoxy chains associate through a combination of van der Waals and C-H...π interactions.

  2. The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis

    International Nuclear Information System (INIS)

    Shaheen, Eman; Van Ongeval, Chantal; Zanca, Federica; Cockmartin, Lesley; Marshall, Nicholas; Jacobs, Jurgen; Young, Kenneth C.; Dance, David R.; Bosmans, Hilde

    2011-01-01

    Purpose: This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. Methods: A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstructed datasets were segmented to obtain 3D models of microcalcification clusters. These models were then adjusted for the x-ray spectrum used and for the system resolution and simulated into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. Six radiologists were asked to distinguish between 40 real and 40 simulated clusters of microcalcifications in two separate studies on 2D mammography and tomosynthesis datasets. Receiver operating characteristic (ROC) analysis was used to test the ability of each observer to distinguish between simulated and real microcalcification clusters. The kappa statistic was applied to assess how often the individual simulated and real microcalcification clusters had received similar scores (''agreement'') on their realistic appearance in both modalities. This analysis was performed for all readers and for the real and the simulated group of microcalcification clusters separately. ''Poor'' agreement would reflect radiologists' confusion between simulated and real clusters, i.e., lesions not systematically evaluated in both modalities as either simulated or real, and would therefore be interpreted as a success of the present models. Results: The area under the ROC curve, averaged over the observers, was 0.55 (95% confidence interval [0.44, 0.66]) for the 2D study, and 0.46 (95% confidence interval [0.29, 0.64]) for the tomosynthesis study, indicating no statistically significant difference between real and simulated

  3. A statistical framework for the validation of a population exposure model based on personal exposure data

    Science.gov (United States)

    Rodriguez, Delphy; Valari, Myrto; Markakis, Konstantinos; Payan, Sébastien

    2016-04-01

    Currently, ambient pollutant concentrations at monitoring sites are routinely measured by local networks, such as AIRPARIF in Paris, France. Pollutant concentration fields are also simulated with regional-scale chemistry transport models such as CHIMERE (http://www.lmd.polytechnique.fr/chimere) under air-quality forecasting platforms (e.g. Prev'Air http://www.prevair.org) or research projects. These data may be combined with more or less sophisticated techniques to provide a fairly good representation of pollutant concentration spatial gradients over urban areas. Here we focus on human exposure to atmospheric contaminants. Based on census data on population dynamics and demographics, modeled outdoor concentrations and infiltration of outdoor air-pollution indoors we have developed a population exposure model for ozone and PM2.5. A critical challenge in the field of population exposure modeling is model validation since personal exposure data are expensive and therefore, rare. However, recent research has made low cost mobile sensors fairly common and therefore personal exposure data should become more and more accessible. In view of planned cohort field-campaigns where such data will be available over the Paris region, we propose in the present study a statistical framework that makes the comparison between modeled and measured exposures meaningful. Our ultimate goal is to evaluate the exposure model by comparing modeled exposures to monitor data. The scientific question we address here is how to downscale modeled data that are estimated on the county population scale at the individual scale which is appropriate to the available measurements. To assess this question we developed a Bayesian hierarchical framework that assimilates actual individual data into population statistics and updates the probability estimate.

  4. Joint interference management and resource allocation for device-to-device (D2D) communications underlying downlink/uplink decoupled (DUDe) heterogeneous networks

    KAUST Repository

    Celik, Abdulkadir

    2017-07-31

    In this paper, resource allocation and co-tier/cross-tier interference management are investigated for D2D-enabled heterogeneous networks (HetNets) where tiers 1, 2, and 3 consist of macrocells, smallcells, and D2D pairs, respectively. We first propose a D2D-enabled fractional frequency reuse scheme for uplink (UL) HetNets where macrocell subregions are preassigned to different subbands (SBs) in order to mitigate the tier-1↔tier-1 interference. Nevertheless, cell-edge macrocell user equipments (MUEs) with high transmission powers still form dead-zones for nearby smallcell UEs (SUEs) and D2D UEs (DUEs). One of the simple but yet novel means of the dead-zone alleviation is associating the cell-edge MUEs with nearby smallcells, which is also known as downlink (DL)/UL decoupling (DUDe). Subject to quality of service (QoS) requirements and power constraints, we formulate a joint SB assignment and resource block (RB) allocation optimization as a mixed integer non-linear programming (MINLP) problem to maximize the D2D sum rate and minimize the co-tier/cross-tier interference. Based on tolerable interference limit, we propose a fast yet high-performance suboptimal solution to jointly assign available SBs and RBs to smallcells. A D2D mode selection and resource allocation framework is then developed for DUEs. As traditional DL/UL Coupled (DUCo) scheme generates significant interference proportional to cellular user density and user association bias factor, results obtained from the combination of proposed methods and developed algorithms reveal the potential of DUDe for co-tier/cross-tier interference mitigation which opens more room for spectrum reuse of DUEs.

  5. Band Alignment of 2D Transition Metal Dichalcogenide Heterojunctions

    KAUST Repository

    Chiu, Ming-Hui

    2016-09-20

    It is critically important to characterize the band alignment in semiconductor heterojunctions (HJs) because it controls the electronic and optical properties. However, the well-known Anderson\\'s model usually fails to predict the band alignment in bulk HJ systems due to the presence of charge transfer at the interfacial bonding. Atomically thin 2D transition metal dichalcogenide materials have attracted much attention recently since the ultrathin HJs and devices can be easily built and they are promising for future electronics. The vertical HJs based on 2D materials can be constructed via van der Waals stacking regardless of the lattice mismatch between two materials. Despite the defect-free characteristics of the junction interface, experimental evidence is still lacking on whether the simple Anderson rule can predict the band alignment of HJs. Here, the validity of Anderson\\'s model is verified for the 2D heterojunction systems and the success of Anderson\\'s model is attributed to the absence of dangling bonds (i.e., interface dipoles) at the van der Waal interface. The results from the work set a foundation allowing the use of powerful Anderson\\'s rule to determine the band alignments of 2D HJs, which is beneficial to future electronic, photonic, and optoelectronic devices. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. New family of lanthanide-based inorganic-organic hybrid frameworks: Ln2(OH)4[O3S(CH2)nSO3]·2H2O (Ln = La, Ce, Pr, Nd, Sm; n = 3, 4) and their derivatives.

    Science.gov (United States)

    Liang, Jianbo; Ma, Renzhi; Ebina, Yasuo; Geng, Fengxia; Sasaki, Takayoshi

    2013-02-18

    We report the synthesis and structure characterization of a new family of lanthanide-based inorganic-organic hybrid frameworks, Ln(2)(OH)(4)[O(3)S(CH(2))(n)SO(3)]·2H(2)O (Ln = La, Ce, Pr, Nd, Sm; n = 3, 4), and their oxide derivatives. Highly crystallized samples were synthesized by homogeneous precipitation of Ln(3+) ions from a solution containing α,ω-organodisulfonate salts promoted by slow hydrolysis of hexamethylenetetramine. The crystal structure solved from powder X-ray diffraction data revealed that this material comprises two-dimensional cationic lanthanide hydroxide {[Ln(OH)(2)(H(2)O)](+)}(∞) layers, which are cross-linked by α,ω-organodisulfonate ligands into a three-dimensional pillared framework. This hybrid framework can be regarded as a derivative of UCl(3)-type Ln(OH)(3) involving penetration of organic chains into two {LnO(9)} polyhedra. Substitutional modification of the lanthanide coordination promotes a 2D arrangement of the {LnO(9)} polyhedra. A new hybrid oxide, Ln(2)O(2)[O(3)S(CH(2))(n)SO(3)], which is supposed to consist of alternating {[Ln(2)O(2)](2+)}(∞) layers and α,ω-organodisulfonate ligands, can be derived from the hydroxide form upon dehydration/dehydroxylation. These hybrid frameworks provide new opportunities to engineer the interlayer chemistry of layered structures and achieve advanced functionalities coupled with the advantages of lanthanide elements.

  7. Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Mitrović, Uroš [Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana 1000, Slovenia and Cosylab, Control System Laboratory, Teslova ulica 30, Ljubljana 1000 (Slovenia); Pernuš, Franjo [Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana 1000 (Slovenia); Likar, Boštjan; Špiclin, Žiga, E-mail: ziga.spiclin@fe.uni-lj.si [Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana 1000, Slovenia and Sensum, Computer Vision Systems, Tehnološki Park 21, Ljubljana 1000 (Slovenia)

    2015-11-15

    Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3D image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and

  8. ELLIPT2D: A Flexible Finite Element Code Written Python

    International Nuclear Information System (INIS)

    Pletzer, A.; Mollis, J.C.

    2001-01-01

    The use of the Python scripting language for scientific applications and in particular to solve partial differential equations is explored. It is shown that Python's rich data structure and object-oriented features can be exploited to write programs that are not only significantly more concise than their counter parts written in Fortran, C or C++, but are also numerically efficient. To illustrate this, a two-dimensional finite element code (ELLIPT2D) has been written. ELLIPT2D provides a flexible and easy-to-use framework for solving a large class of second-order elliptic problems. The program allows for structured or unstructured meshes. All functions defining the elliptic operator are user supplied and so are the boundary conditions, which can be of Dirichlet, Neumann or Robbins type. ELLIPT2D makes extensive use of dictionaries (hash tables) as a way to represent sparse matrices.Other key features of the Python language that have been widely used include: operator over loading, error handling, array slicing, and the Tkinter module for building graphical use interfaces. As an example of the utility of ELLIPT2D, a nonlinear solution of the Grad-Shafranov equation is computed using a Newton iterative scheme. A second application focuses on a solution of the toroidal Laplace equation coupled to a magnetohydrodynamic stability code, a problem arising in the context of magnetic fusion research

  9. Validation of the Gatortail method for accurate sizing of pulmonary vessels from 3D medical images.

    Science.gov (United States)

    O'Dell, Walter G; Gormaley, Anne K; Prida, David A

    2017-12-01

    Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-user variability. Automatic methods of vessel sizing have been developed for two-dimensional images but a fully three-dimensional (3D) method suitable for vessel sizing from volumetric X-ray computed tomography (CT) or magnetic resonance imaging has heretofore not been demonstrated and validated robustly. In this paper, we refined and objectively validated Gatortail, a method that creates a mathematical geometric 3D model of each branch in a vascular tree, simulates the appearance of the virtual vascular tree in a 3D CT image, and uses the similarity of the simulated image to a patient's CT scan to drive the optimization of the model parameters, including vessel size, to match that of the patient. The method was validated with a 2-dimensional virtual tree structure under deformation, and with a realistic 3D-printed vascular phantom in which the diameter of 64 branches were manually measured 3 times each. The phantom was then scanned on a conventional clinical CT imaging system and the images processed with the in-house software to automatically segment and mathematically model the vascular tree, label each branch, and perform the Gatortail optimization of branch size and trajectory. Previously proposed methods of vessel sizing using matched Gaussian filters and tubularity metrics were also tested. The Gatortail method was then demonstrated on the pulmonary arterial tree segmented from a human volunteer's CT scan. The standard deviation of the difference between the manually measured and Gatortail-based radii in the 3D physical phantom was 0.074 mm (0.087 in-plane pixel units for image voxels of dimension 0.85 × 0.85 × 1.0 mm) over the 64 branches

  10. Validity of colour doppler ultrasonography with d-dimers in clinically suspected deep venous thrombosis of the lower limb

    International Nuclear Information System (INIS)

    Babar, T.H.; Nafees, M.N.; Sarwar, S.; Ashraf, N.

    2010-01-01

    Objective: This study was designed to evaluate the validity of colour Doppler ultrasonography with D-dimers in clinically suspected deep venous thrombosis of the lower limb. Study Design: Validation study Place and Duration of study: Radiology Department CMH/MH Rawalpindi Six months from 15 June 2006 to 31 December 2006. Subjects and Methods: Thirty cases of clinically suspected deep venous thrombosis of the lower limb were included in the study selected on non probability convenience sampling technique. Colour Doppler ultrasonography examination of the affected lower limb was carried out and results compared with D-dimers assays results. Results: Among 30 patients who underwent colour Doppler ultrasonography examination of the affected limb for diagnosis of deep venous thrombosis, 27 (90%) were diagnosed to have deep venous thrombosis, 3 (10%) were diagnosed not to have deep venous thrombosis. Amongst them 2 patients had raised D-dimers levels and repeat Doppler ultrasound advised. On revised ultrasound deep venous thrombosis in these patients was confirmed. This showed that colour Doppler ultrasonography examination has sensitivity of 93.1%, specificity 100%, positive predictive value 100%, negative predictive value 33.33% and overall accuracy of 93.33 %. Conclusion: Colour Doppler ultrasonography has a high diagnostic yield in cases of deep venous thrombosis of lower limb when used in conjunction with D-dimers assays. (author)

  11. Strategic framework for education and training in Quality by Design (QbD) and process analytical technology (PAT).

    Science.gov (United States)

    de Matas, Marcel; De Beer, Thomas; Folestad, Staffan; Ketolainen, Jarkko; Lindén, Hans; Lopes, João Almeida; Oostra, Wim; Weimer, Marco; Öhrngren, Per; Rantanen, Jukka

    2016-07-30

    The regulatory and technical landscape of the pharmaceutical field is rapidly evolving from one focused predominantly on development of small molecules, using well established manufacturing technologies towards an environment in which biologicals and complex modalities are being developed using advanced science and technology coupled with the application of modern Quality by Design (QbD) principles. In order that Europe keeps pace with these changes and sustains its position as major player in the development and commercialization of medicines, it is essential that measures are put in place to maintain a highly skilled workforce. A number of challenges however exist to equipping academic, industrial and health agency staff with the requisite knowledge, skills and experience to develop the next generation of medicines. In this regard, the EUFEPS QbD and PAT Sciences Network has proposed a structured framework for education, training and continued professional development, which comprises a number of pillars covering the fundamental principles of modern pharmaceutical development including the underpinning aspects of science, engineering and technology innovation. The framework is not prescriptive and is not aimed at describing specific course content in detail. It should however be used as a point of reference for those institutions delivering pharmaceutical based educational courses, to ensure that the necessary skills, knowledge and experience for successful pharmaceutical development are maintained. A positive start has been made and a number of examples of formal higher education courses and short training programs containing elements of this framework have been described. The ultimate vision for this framework however, is to see widespread adoption and proliferation of this curriculum with it forming the backbone of QbD and PAT science based skills development. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Reliability and validity of the German version of the Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty (D-OAR).

    Science.gov (United States)

    Spiekermann, Christoph; Rudack, Claudia; Stenner, Markus

    2017-11-01

    The outcome of aesthetic rhinoplasty is determined by the patient's subjective satisfaction with the nasal appearance which is difficult to assess. The Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty (OAR) is a brief and reliable instrument to assess the influence of the subjective nasal appearance on quality of life in patients undergoing aesthetic rhinoplasty. Preoperative application of this questionnaire reveals important aspects and possible disturbances of the body image which could be negative predictors concerning the result. On the other hand, it represents an appropriate tool to assess the postoperative outcome. The aim of this study was to determine the validity, reliability and responsiveness of the adapted German version of the OAR (D-OAR). The adaption of the OAR to German language was performed by a forward and backward translation process. Patients undergoing rhinoplasty were asked to complete the D-OAR preoperatively, 1, 3 and 12 months after procedure and healthy volunteers without any nasal complaints served as controls to test validity, reliability and responsiveness. An excellent internal consistency, a good test-retest reliability and good inter-item and item-total correlations demonstrated a good reliability of the D-OAR. The convincing validity of the adapted version was proven by an excellent discriminant and a sufficient content validity. Significant differences between pre- and postoperative D-OAR scores revealed a good responsiveness of the instrument. Hence, with a sufficient validity, reliability and sensitivity to changes, the D-OAR is a short and helpful instrument to assess the subjective perception of the nasal appearance in German patients.

  13. Synthesis of 2-acetamido-6-O-(5-acetamido-3,5-dideoxy-β-D-glycero-D-galacto-2-nonulo-pyranosylonic acid)-2-deoxy-D-glucose [2-acetamido-6-O-(N-acetyl-β-D-neuraminyl)-2-deoxy-D-glucose

    NARCIS (Netherlands)

    Vliegenthart, J.F.G.; Vleugel, D.J.M. van der; Zwikker, J.W.; Boeckel, S.A.A. van; Boom, J.H. van

    1982-01-01

    Silver triflate-promoted condensation of methyl 5-acetamido-4,7,8,9-tetra-O-acetyl-2-chloro-2,3,5-trideoxy-β-D-glycero-D-galacto -2-nonulopyranosonate (9) with benzyl-2-acetamido-2-deoxy-3,4-O-(1,1,3,3-tetraisopropyldisiloxane-1,3-diyl)-α-D-glucopyranoside, followed by removal of the

  14. D3-??????????????????????? ? ???? ?????????? ?2 ?????? ?????? ?????

    OpenAIRE

    ?????????, ????; ???????, ???????; ??????, ?????????; ?????????????, ????; ??????, ??????

    2011-01-01

    ????? ?????? ??????? ????? ????? ??????????? ?????? ?????? ????? ? ?????? ? ???????? ????? ?????????. ?????????? ???????????? ?????? ?? ?2 ?????? ?????? ????? ??????? ?? D3 ???????????????? ??????? ??????????? ?????? ????????? ????? ?????????? ??? ??? ??????????. ? ????? ????????????? ??????????? ??? ????????? ????????????? ?????????? ???? ?????????? ?????????? ????? ????????? ?????? ???????? ?? D3-????????????????? ???????.

  15. Assessing citation networks for dissemination and implementation research frameworks.

    Science.gov (United States)

    Skolarus, Ted A; Lehmann, Todd; Tabak, Rachel G; Harris, Jenine; Lecy, Jesse; Sales, Anne E

    2017-07-28

    A recent review of frameworks used in dissemination and implementation (D&I) science described 61 judged to be related either to dissemination, implementation, or both. The current use of these frameworks and their contributions to D&I science more broadly has yet to be reviewed. For these reasons, our objective was to determine the role of these frameworks in the development of D&I science. We used the Web of Science™ Core Collection and Google Scholar™ to conduct a citation network analysis for the key frameworks described in a recent systematic review of D&I frameworks (Am J Prev Med 43(3):337-350, 2012). From January to August 2016, we collected framework data including title, reference, publication year, and citations per year and conducted descriptive and main path network analyses to identify those most important in holding the current citation network for D&I frameworks together. The source article contained 119 cited references, with 50 published articles and 11 documents identified as a primary framework reference. The average citations per year for the 61 frameworks reviewed ranged from 0.7 to 103.3 among articles published from 1985 to 2012. Citation rates from all frameworks are reported with citation network analyses for the framework review article and ten highly cited framework seed articles. The main path for the D&I framework citation network is presented. We examined citation rates and the main paths through the citation network to delineate the current landscape of D&I framework research, and opportunities for advancing framework development and use. Dissemination and implementation researchers and practitioners may consider frequency of framework citation and our network findings when planning implementation efforts to build upon this foundation and promote systematic advances in D&I science.

  16. In vivo validation of a 3D ultrasound system for imaging the lateral ventricles of neonates

    Science.gov (United States)

    Kishimoto, J.; Fenster, A.; Chen, N.; Lee, D.; de Ribaupierre, S.

    2014-03-01

    Dilated lateral ventricles in neonates can be due to many different causes, such as brain loss, or congenital malformation; however, the main cause is hydrocephalus, which is the accumulation of fluid within the ventricular system. Hydrocephalus can raise intracranial pressure resulting in secondary brain damage, and up to 25% of patients with severely enlarged ventricles have epilepsy in later life. Ventricle enlargement is clinically monitored using 2D US through the fontanels. The sensitivity of 2D US to dilation is poor because it cannot provide accurate measurements of irregular volumes such as the ventricles, so most clinical evaluations are of a qualitative nature. We developed a 3D US system to image the cerebral ventricles of neonates within the confines of incubators that can be easily translated to more open environments. Ventricle volumes can be segmented from these images giving a quantitative volumetric measurement of ventricle enlargement without moving the patient into an imaging facility. In this paper, we report on in vivo validation studies: 1) comparing 3D US ventricle volumes before and after clinically necessary interventions removing CSF, and 2) comparing 3D US ventricle volumes to those from MRI. Post-intervention ventricle volumes were less than pre-intervention measurements for all patients and all interventions. We found high correlations (R = 0.97) between the difference in ventricle volume and the reported removed CSF with the slope not significantly different than 1 (p < 0.05). Comparisons between ventricle volumes from 3D US and MR images taken 4 (±3.8) days of each other did not show significant difference (p=0.44) between 3D US and MRI through paired t-test.

  17. Empirical validation and proof of added value of MUSICA's tropospheric δD remote sensing products

    Science.gov (United States)

    Schneider, M.; González, Y.; Dyroff, C.; Christner, E.; Wiegele, A.; Barthlott, S.; García, O. E.; Sepúlveda, E.; Hase, F.; Andrey, J.; Blumenstock, T.; Guirado, C.; Ramos, R.; Rodríguez, S.

    2015-01-01

    The project MUSICA (MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water) integrates tropospheric water vapour isotopologue remote sensing and in situ observations. This paper presents a first empirical validation of MUSICA's H2O and δD remote sensing products, generated from ground-based FTIR (Fourier transform infrared), spectrometer and space-based IASI (infrared atmospheric sounding interferometer) observation. The study is made in the area of the Canary Islands in the subtropical northern Atlantic. As reference we use well calibrated in situ measurements made aboard an aircraft (between 200 and 6800 m a.s.l.) by the dedicated ISOWAT instrument and on the island of Tenerife at two different altitudes (at Izaña, 2370 m a.s.l., and at Teide, 3550 m a.s.l.) by two commercial Picarro L2120-i water isotopologue analysers. The comparison to the ISOWAT profile measurements shows that the remote sensors can well capture the variations in the water vapour isotopologues, and the scatter with respect to the in situ references suggests a δD random uncertainty for the FTIR product of much better than 45‰ in the lower troposphere and of about 15‰ for the middle troposphere. For the middle tropospheric IASI δD product the study suggests a respective uncertainty of about 15‰. In both remote sensing data sets we find a positive δD bias of 30-70‰. Complementing H2O observations with δD data allows moisture transport studies that are not possible with H2O observations alone. We are able to qualitatively demonstrate the added value of the MUSICA δD remote sensing data. We document that the δD-H2O curves obtained from the different in situ and remote sensing data sets (ISOWAT, Picarro at Izaña and Teide, FTIR, and IASI) consistently identify two different moisture transport pathways to the subtropical north eastern Atlantic free troposphere.

  18. 2-D and 3-D CFD Investigation of NREL S826 Airfoil at Low Reynolds Numbers

    International Nuclear Information System (INIS)

    Cakmakcioglu, S C; Sert, I O; Tugluk, O; Sezer-Uzol, N

    2014-01-01

    In this study CFD investigation of flow over the NREL S826 airfoil is performed. NREL S826 airfoil was designed for HAWTs of 10-15 meter diameters. However, it is used in the NTNU wind turbine rotor model and low Reynolds number flow characteristics become important in the validations with the test cases of this rotor model. The airfoil CFD simulations are carried out in 2-D and 3-D computational domains. The k-rn SST turbulence model with Langtry-Menter (γ-Re θ ) transition prediction model for turbulence closure is used in the calculations. The Delayed DES is also performed in the stall region for comparisons. The results are compared with the available METUWIND experimental data, and are shown to be in fair agreement. It is observed that 3-D CFD analysis provides increased accuracy at increased computational cost

  19. Computing K and D meson masses with N{sub f}=2+1+1 twisted mass lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Baron, Remi [CEA, Centre de Saclay, 91 - Gif-sur-Yvette (France). IRFU/Service de Physique Nucleaire; Blossier, Benoit; Boucaud, Philippe [Paris XI Univ., 91 - Orsay (FR). Lab. de Physique Theorique] (and others)

    2010-05-15

    We discuss the computation of the mass of the K and D mesons within the framework of N{sub f}=2+1+1 twisted mass lattice QCD from a technical point of view. These quantities are essential, already at the level of generating gauge configurations, being obvious candidates to tune the strange and charm quark masses to their physical values. In particular, we address the problems related to the twisted mass flavor and parity symmetry breaking, which arise when considering a non-degenerate (c,s) doublet. We propose and verify the consistency of three methods to extract the K and D meson masses in this framework. (orig.)

  20. Development of the Korean framework for senior-friendly hospitals: a Delphi study.

    Science.gov (United States)

    Kim, Yoon-Sook; Han, Seol-Heui; Hwang, Jeong-Hae; Park, Jae-Min; Lee, Jongmin; Choi, Jaekyung; Moon, Yeonsil; Kim, Hee Joung; Shin, Grace Jung Eun; Lee, Ji-Sun; Choi, Ye Ji; Uhm, Kyeong Eun; Kim, In Ae; Nam, Ji-Won

    2017-08-04

    Aging is an inevitable part of life. One can maintain well-being and wellness even after discharge and/or transition if his or her functional decline is minimized, sudden decline is prevented, and functioning is promoted during hospitalization. Caring appropriately for elderly patients requires the systematic application of Senior-Friendly Hospital principles to all operating systems, including medical centres' organization and environment, as well as patient treatment processes. The Senior-Friendly Hospital framework is valid and important for patient safety and quality improvement. This study aimed to make recommendations regarding the development of the Korean Framework for Senior-Friendly Hospitals for older patients' care management, patient safety interventions, and health promotion, via a Delphi survey. Two rounds of Delphi surveying were conducted with 15 participants who had at least 3 years' experience in accreditation surveying and medical accreditation standards, survey methods, and accreditation investigator education. In each round, we calculated statistics describing each standard's validity and feasibility. The Korean Framework for Senior-Friendly Hospitals included 4 Chapters, 11 categories, and 67 standards through consensus of the Senior-Friendly Hospitals task force and experts' peer review. After the two rounds of Delphi surveying, validity evaluation led to no changes in standards of the Senior-Friendly Hospitals; however, the number of standards showing adequate validity decreased from 67 to 58. Regarding feasibility, no changes were necessary in the standards; however, the number of categories showing adequate feasibility decreased from 11 to 8 and from 67 to 30, respectively. The excluded categories were 3.2, 4.2, and 4.3 (service, transportation, and signage and identification). The highest feasibility values were given to standards 2.1.1, 4.1.4, and 4.1.6. The highest feasibility score was given to standard 2.4.2. The Korean Framework for

  1. Experimental validation of a 2D overland flow model using high resolution water depth and velocity data

    Science.gov (United States)

    Cea, L.; Legout, C.; Darboux, F.; Esteves, M.; Nord, G.

    2014-05-01

    This paper presents a validation of a two-dimensional overland flow model using empirical laboratory data. Unlike previous publications in which model performance is evaluated as the ability to predict an outlet hydrograph, we use high resolution 2D water depth and velocity data to analyze to what degree the model is able to reproduce the spatial distribution of these variables. Several overland flow conditions over two impervious surfaces of the order of one square meter with different micro and macro-roughness characteristics are studied. The first surface is a simplified representation of a sinusoidal terrain with three crests and furrows, while the second one is a mould of a real agricultural seedbed terrain. We analyze four different bed friction parameterizations and we show that the performance of formulations which consider the transition between laminar, smooth turbulent and rough turbulent flow do not improve the results obtained with Manning or Keulegan formulas for rough turbulent flow. The simulations performed show that using Keulegan formula with a physically-based definition of the bed roughness coefficient, a two-dimensional shallow water model is able to reproduce satisfactorily the flow hydrodynamics. It is shown that, even if the resolution of the topography data and numerical mesh are high enough to include all the small scale features of the bed surface, the roughness coefficient must account for the macro-roughness characteristics of the terrain in order to correctly reproduce the flow hydrodynamics.

  2. Comparison of PIV with 4D-Flow in a physiological accurate flow phantom

    Science.gov (United States)

    Sansom, Kurt; Balu, Niranjan; Liu, Haining; Aliseda, Alberto; Yuan, Chun; Canton, Maria De Gador

    2016-11-01

    Validation of 4D MRI flow sequences with planar particle image velocimetry (PIV) is performed in a physiologically-accurate flow phantom. A patient-specific phantom of a carotid artery is connected to a pulsatile flow loop to simulate the 3D unsteady flow in the cardiovascular anatomy. Cardiac-cycle synchronized MRI provides time-resolved 3D blood velocity measurements in clinical tool that is promising but lacks a robust validation framework. PIV at three different Reynolds numbers (540, 680, and 815, chosen based on +/- 20 % of the average velocity from the patient-specific CCA waveform) and four different Womersley numbers (3.30, 3.68, 4.03, and 4.35, chosen to reflect a physiological range of heart rates) are compared to 4D-MRI measurements. An accuracy assessment of raw velocity measurements and a comparison of estimated and measureable flow parameters such as wall shear stress, fluctuating velocity rms, and Lagrangian particle residence time, will be presented, with justification for their biomechanics relevance to the pathophysiology of arterial disease: atherosclerosis and intimal hyperplasia. Lastly, the framework is applied to a new 4D-Flow MRI sequence and post processing techniques to provide a quantitative assessment with the benchmarked data. Department of Education GAANN Fellowship.

  3. Multilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection.

    Science.gov (United States)

    Dou, Qi; Chen, Hao; Yu, Lequan; Qin, Jing; Heng, Pheng-Ann

    2017-07-01

    False positive reduction is one of the most crucial components in an automated pulmonary nodule detection system, which plays an important role in lung cancer diagnosis and early treatment. The objective of this paper is to effectively address the challenges in this task and therefore to accurately discriminate the true nodules from a large number of candidates. We propose a novel method employing three-dimensional (3-D) convolutional neural networks (CNNs) for false positive reduction in automated pulmonary nodule detection from volumetric computed tomography (CT) scans. Compared with its 2-D counterparts, the 3-D CNNs can encode richer spatial information and extract more representative features via their hierarchical architecture trained with 3-D samples. More importantly, we further propose a simple yet effective strategy to encode multilevel contextual information to meet the challenges coming with the large variations and hard mimics of pulmonary nodules. The proposed framework has been extensively validated in the LUNA16 challenge held in conjunction with ISBI 2016, where we achieved the highest competition performance metric (CPM) score in the false positive reduction track. Experimental results demonstrated the importance and effectiveness of integrating multilevel contextual information into 3-D CNN framework for automated pulmonary nodule detection in volumetric CT data. While our method is tailored for pulmonary nodule detection, the proposed framework is general and can be easily extended to many other 3-D object detection tasks from volumetric medical images, where the targeting objects have large variations and are accompanied by a number of hard mimics.

  4. Active Transportation Demand Management (ATDM) Trajectory Level Validation

    Data.gov (United States)

    Department of Transportation — The ATDM Trajectory Validation project developed a validation framework and a trajectory computational engine to compare and validate simulated and observed vehicle...

  5. GPS tomography. Validation of reconstructed 3-D humidity fields with radiosonde profiles

    Energy Technology Data Exchange (ETDEWEB)

    Shangguan, M.; Bender, M.; Ramatschi, M.; Dick, G.; Wickert, J. [Helmholtz Centre Potsdam, German Research Centre for Geosciences (GFZ), Potsdam (Germany); Raabe, A. [Leipzig Institute for Meteorology (LIM), Leipzig (Germany); Galas, R. [Technische Univ. Berlin (Germany). Dept. for Geodesy and Geoinformation Sciences

    2013-11-01

    Water vapor plays an important role in meteorological applications; GeoForschungsZentrum (GFZ) therefore developed a tomographic system to derive 3-D distributions of the tropospheric water vapor above Germany using GPS data from about 300 ground stations. Input data for the tomographic reconstructions are generated by the Earth Parameter and Orbit determination System (EPOS) software of the GFZ, which provides zenith total delay (ZTD), integrated water vapor (IWV) and slant total delay (STD) data operationally with a temporal resolution of 2.5 min (STD) and 15 min (ZTD, IWV). The water vapor distribution in the atmosphere is derived by tomographic reconstruction techniques. The quality of the solution is dependent on many factors such as the spatial coverage of the atmosphere with slant paths, the spatial distribution of their intersections and the accuracy of the input observations. Independent observations are required to validate the tomographic reconstructions and to get precise information on the accuracy of the derived 3-D water vapor fields. To determine the quality of the GPS tomography, more than 8000 vertical water vapor profiles at 13 German radiosonde stations were used for the comparison. The radiosondes were launched twice a day (at 00:00 UTC and 12:00 UTC) in 2007. In this paper, parameters of the entire profiles such as the wet refractivity, and the zenith wet delay have been compared. Before the validation the temporal and spatial distribution of the slant paths, serving as a basis for tomographic reconstruction, as well as their angular distribution were studied. The mean wet refractivity differences between tomography and radiosonde data for all points vary from -1.3 to 0.3, and the root mean square is within the range of 6.5-9. About 32% of 6803 profiles match well, 23% match badly and 45% are difficult to classify as they match only in parts.

  6. Good Practice Policy Framework for Energy Technology Research Development and Demonstration (RD and D)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    The transition to a low carbon economy clearly requires accelerating energy innovation and technology adoption. Governments have an important role in this context. They can help by establishing the enabling environment in which innovation can thrive, and within which effective and efficient policies can be identified, with the specific goal of advancing research, development, demonstration and, ultimately, deployment (RDD&D) of clean energy technologies. At the front end of the innovation process, significant increases in, and restructuring of, global RD&D efforts will be required, combined with well-targeted government RD&D policies. The development of a clear policy framework for energy technology RD&D, based on good practices, should include six elements: Coherent energy RD&D strategy and priorities; Adequate government RD&D funding and policy support; Co-ordinated energy RD&D governance; Strong collaborative approach, engaging industry through public private partnerships (PPPs); Effective RD&D monitoring and evaluation; and Strategic international collaboration. While countries have been favouring certain technologies over others, based on decisions on which areas are to receive funding, clear priorities are not always determined through structured analysis and documented processes. A review of stated energy RD&D priorities, based on announced technology programmes and strategies, and recent spending trends reveals some important deviations from stated priorities and actual RD&D funding.

  7. New metal-organic frameworks of [M(C6H5O7)(C6H6O7)(C6H7O7)(H2O)] . H2O (M=La, Ce) and [Ce2(C2O4)(C6H6O7)2] . 4H2O

    International Nuclear Information System (INIS)

    Weng Shengfeng; Wang, Yun-Hsin; Lee, Chi-Shen

    2012-01-01

    Two novel materials, [M(C 6 H 5 O 7 )(C 6 H 6 O 7 )(C 6 H 7 O 7 )(H 2 O)] . H 2 O (M=La(1a), Ce(1b)) and [Ce 2 (C 2 O 4 )(C 6 H 6 O 7 ) 2 ] . 4H 2 O (2), with a metal-organic framework (MOF) were prepared with hydrothermal reactions and characterized with photoluminescence, magnetic susceptibility, thermogravimetric analysis and X-ray powder diffraction in situ. The crystal structures were determined by single-crystal X-ray diffraction. Compound 1 crystallized in triclinic space group P1-bar (No. 2); compound 2 crystallized in monoclinic space group P2 1 /c (No. 14). The structure of 1 is built from a 1D MOF, composed of deprotonated citric ligands of three kinds. Compound 2 contains a 2D MOF structure consisting of citrate and oxalate ligands; the oxalate ligand arose from the decomposition in situ of citric acid in the presence of Cu II ions. Photoluminescence spectra of compounds 1b and 2 revealed transitions between the 5d 1 excited state and two levels of the 4f 1 ground state ( 2 F 5/2 and 2 F 7/2 ). Compounds 1b and 2 containing Ce III ion exhibit a paramagnetic property with weak antiferromagnetic interactions between the two adjacent magnetic centers. - Graphical Abstract: [M(C 6 H 5 O 7 )(C 6 H 6 O 7 )(C 6 H 7 O 7 )(H 2 O)] . H 2 O (M=La(1a), Ce(1b)) and [Ce 2 (C 2 O 4 )(C 6 H 6 O 7 ) 2 ] . 4H 2 O (2)—with 1D and 2D structures were synthesized and characterized. Highlights: ► Two MOF – [M(C 6 H 5 O 7 )(C 6 H 6 O 7 )(C 6 H 7 O 7 )(H 2 O)] . H 2 O (M=La(1a), Ce(1b)) and [Ce 2 (C 2 O 4 )(C 6 H 6 O 7 ) 2 ] . 4H 2 O (2) – with 1D and 2D structures. ► The adjacent chains of the 1D framework were correlated with each other through an oxalate ligand to form a 2D layer structure. ► The source of the oxalate ligand was the decomposition in situ of citric acid oxidized in the presence of Cu II ions.

  8. Highly stable [mambf6-n(o/h2o)n(ligand)2(solvent)x]n metal organic frameworks

    KAUST Repository

    Eddaoudi, Mohamed

    2016-10-13

    Provided herein are metal organic frameworks having high selectivity and stability in the present of gases and vapors including H2S, H2O, and CO2. Metal organic frameworks can comprise metal nodes and N-donor organic ligands. Further provided are methods of making metal organic frameworks.

  9. A novel 2.5D finite difference scheme for simulations of resistivity logging in anisotropic media

    Science.gov (United States)

    Zeng, Shubin; Chen, Fangzhou; Li, Dawei; Chen, Ji; Chen, Jiefu

    2018-03-01

    The objective of this study is to develop a method to model 3D resistivity well logging problems in 2D formation with anisotropy, known as 2.5D modeling. The traditional 1D forward modeling extensively used in practice lacks the capability of modeling 2D formation. A 2.5D finite difference method (FDM) solving all the electric and magnetic field components simultaneously is proposed. Compared to other previous 2.5D FDM schemes, this method is more straightforward in modeling fully anisotropic media and easy to be implemented. Fourier transform is essential to this FDM scheme, and by employing Gauss-Legendre (GL) quadrature rule the computational time of this step can be greatly reduced. In the numerical examples, we first demonstrate the validity of the FDM scheme with GL rule by comparing with 1D forward modeling for layered anisotropic problems, and then we model a complicated 2D formation case and find that the proposed 2.5D FD scheme is much more efficient than 3D numerical methods.

  10. Development and validation of real-time simulation of X-ray imaging with respiratory motion.

    Science.gov (United States)

    Vidal, Franck P; Villard, Pierre-Frédéric

    2016-04-01

    We present a framework that combines evolutionary optimisation, soft tissue modelling and ray tracing on GPU to simultaneously compute the respiratory motion and X-ray imaging in real-time. Our aim is to provide validated building blocks with high fidelity to closely match both the human physiology and the physics of X-rays. A CPU-based set of algorithms is presented to model organ behaviours during respiration. Soft tissue deformation is computed with an extension of the Chain Mail method. Rigid elements move according to kinematic laws. A GPU-based surface rendering method is proposed to compute the X-ray image using the Beer-Lambert law. It is provided as an open-source library. A quantitative validation study is provided to objectively assess the accuracy of both components: (i) the respiration against anatomical data, and (ii) the X-ray against the Beer-Lambert law and the results of Monte Carlo simulations. Our implementation can be used in various applications, such as interactive medical virtual environment to train percutaneous transhepatic cholangiography in interventional radiology, 2D/3D registration, computation of digitally reconstructed radiograph, simulation of 4D sinograms to test tomography reconstruction tools. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. The validation of an infrared simulation system

    CSIR Research Space (South Africa)

    De Waal, A

    2013-08-01

    Full Text Available theoretical validation framework. This paper briefly describes the procedure used to validate software models in an infrared system simulation, and provides application examples of this process. The discussion includes practical validation techniques...

  12. Model-based Systems Engineering: Creation and Implementation of Model Validation Rules for MOS 2.0

    Science.gov (United States)

    Schmidt, Conrad K.

    2013-01-01

    Model-based Systems Engineering (MBSE) is an emerging modeling application that is used to enhance the system development process. MBSE allows for the centralization of project and system information that would otherwise be stored in extraneous locations, yielding better communication, expedited document generation and increased knowledge capture. Based on MBSE concepts and the employment of the Systems Modeling Language (SysML), extremely large and complex systems can be modeled from conceptual design through all system lifecycles. The Operations Revitalization Initiative (OpsRev) seeks to leverage MBSE to modernize the aging Advanced Multi-Mission Operations Systems (AMMOS) into the Mission Operations System 2.0 (MOS 2.0). The MOS 2.0 will be delivered in a series of conceptual and design models and documents built using the modeling tool MagicDraw. To ensure model completeness and cohesiveness, it is imperative that the MOS 2.0 models adhere to the specifications, patterns and profiles of the Mission Service Architecture Framework, thus leading to the use of validation rules. This paper outlines the process by which validation rules are identified, designed, implemented and tested. Ultimately, these rules provide the ability to maintain model correctness and synchronization in a simple, quick and effective manner, thus allowing the continuation of project and system progress.

  13. 2D or Not 2D? Testing the Utility of 2D Vs. 3D Landmark Data in Geometric Morphometrics of the Sculpin Subfamily Oligocottinae (Pisces; Cottoidea).

    Science.gov (United States)

    Buser, Thaddaeus J; Sidlauskas, Brian L; Summers, Adam P

    2018-05-01

    We contrast 2D vs. 3D landmark-based geometric morphometrics in the fish subfamily Oligocottinae by using 3D landmarks from CT-generated models and comparing the morphospace of the 3D landmarks to one based on 2D landmarks from images. The 2D and 3D shape variables capture common patterns across taxa, such that the pairwise Procrustes distances among taxa correspond and the trends captured by principal component analysis are similar in the xy plane. We use the two sets of landmarks to test several ecomorphological hypotheses from the literature. Both 2D and 3D data reject the hypothesis that head shape correlates significantly with the depth at which a species is commonly found. However, in taxa where shape variation in the z-axis is high, the 2D shape variables show sufficiently strong distortion to influence the outcome of the hypothesis tests regarding the relationship between mouth size and feeding ecology. Only the 3D data support previous studies which showed that large mouth sizes correlate positively with high percentages of elusive prey in the diet. When used to test for morphological divergence, 3D data show no evidence of divergence, while 2D data show that one clade of oligocottines has diverged from all others. This clade shows the greatest degree of z-axis body depth within Oligocottinae, and we conclude that the inability of the 2D approach to capture this lateral body depth causes the incongruence between 2D and 3D analyses. Anat Rec, 301:806-818, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. A Framework of Mathematics Inductive Reasoning

    Science.gov (United States)

    Christou, Constantinos; Papageorgiou, Eleni

    2007-01-01

    Based on a synthesis of the literature in inductive reasoning, a framework for prescribing and assessing mathematics inductive reasoning of primary school students was formulated and validated. The major constructs incorporated in this framework were students' cognitive abilities of finding similarities and/or dissimilarities among attributes and…

  15. Yb5Ni4Sn10 and Yb7Ni4Sn13: New polar intermetallics with 3D framework structures

    International Nuclear Information System (INIS)

    Lei Xiaowu; Sun Zhongming; Li Longhua; Zhong Guohua; Hu Chunli; Mao Jianggao

    2010-01-01

    The title compounds have been obtained by solid state reactions of the corresponding pure elements at high temperature, and structurally characterized by single-crystal X-ray diffraction studies. Yb 5 Ni 4 Sn 10 adopts the Sc 5 Co 4 Si 10 structure type and crystallizes in the tetragonal space group P4/mbm (No. 127) with cell parameters of a=13.785(4) A, c=4.492 (2) A, V=853.7(5) A 3 , and Z=2. Yb 7 Ni 4 Sn 13 is isostructural with Yb 7 Co 4 InGe 12 and crystallizes in the tetragonal space group P4/m (No. 83) with cell parameters of a=11.1429(6) A, c=4.5318(4) A, V=562.69(7) A 3 , and Z=1. Both structures feature three-dimensional (3D) frameworks based on three different types of one-dimensional (1D) channels, which are occupied by the Yb atoms. Electronic structure calculations based on density functional theory (DFT) indicate that both compounds are metallic. These results are in agreement with those from temperature-dependent resistivity and magnetic susceptibility measurements. - Graphical abstract: Two new ytterbium nickel stannides, namely, Yb 5 Ni 4 Sn 10 and Yb 7 Ni 4 Sn 13 , have been synthesized and structurally characterized by single-crystal X-ray diffraction studies. Both their structures feature three-dimensional (3D) frameworks based on three different types of one-dimensional (1D) channels, which are situated by all the Yb atoms. Electronic structure calculations based on density functional theory (DFT) indicate that both compounds are metallic, which are in accordance with the results from temperature-dependent resistivity and magnetic susceptibility measurements.

  16. Lectures on 2D gravity and 2D string theory

    International Nuclear Information System (INIS)

    Ginsparg, P.; Moore, G.

    1992-01-01

    This report the following topics: loops and states in conformal field theory; brief review of the Liouville theory; 2D Euclidean quantum gravity I: path integral approach; 2D Euclidean quantum gravity II: canonical approach; states in 2D string theory; matrix model technology I: method of orthogonal polynomials; matrix model technology II: loops on the lattice; matrix model technology III: free fermions from the lattice; loops and states in matrix model quantum gravity; loops and states in the C=1 matrix model; 6V model fermi sea dynamics and collective field theory; and string scattering in two spacetime dimensions

  17. Has 4D transperineal ultrasound additional value over 2D transperineal ultrasound for diagnosing obstructed defaecation syndrome?

    Science.gov (United States)

    van Gruting, I M A; Kluivers, K; Sultan, A H; De Bin, R; Stankiewicz, A; Blake, H; Thakar, R

    2018-06-08

    To establish the diagnostic test accuracy of both two-dimensional (2D) and four-dimensional (4D) transperineal ultrasound, to assess if 4D ultrasound imaging provides additional value in the diagnosis of posterior pelvic floor disorders in women with obstructed defaecation syndrome. In this prospective cohort study, 121 consecutive women with obstructed defaecation syndrome were recruited. Symptoms of obstructed defaecation and signs of pelvic organ prolapse were assessed using validated methods. All women underwent both 2D transperineal ultrasound (Pro-focus, 8802 transducer, BK-medical) and 4D transperineal ultrasound (Voluson i, RAB4-8-RS transducer, GE). Imaging analysis was performed by two blinded observers. Pelvic floor disorders were dichotomised into presence or absence according pre-defined cut-off values. In the absence of a reference standard a composite reference standard was created from a combination of results of evacuation proctogram, magnetic resonance imaging and endovaginal ultrasound. Primary outcome measures were diagnostic test characteristics of 2D and 4D transperineal ultrasound for diagnosis or rectocele, enterocele, intussusception and anismus. Secondary outcome measures were interobserver agreement, agreement between the two techniques and correlation of signs and symptoms to imaging findings. For diagnosis of all four posterior pelvic floor disorders there was no difference in sensitivity and specificity between 2D and 4D TPUS (p= 0.131 - 1.000). A good agreement between 2D and 4D TPUS was found for the diagnosis of rectocele (ĸ 0.675) and a moderate agreement for diagnosis of enterocele, intussusception and anismus (ĸ 0.465 - 0.545). There was no difference in rectocele depth measurements between both TPUS techniques (19.9 mm vs 19.0 mm, p=0.802). Inter-observer agreement was comparable for both techniques, however 2D TPUS had an excellent interobserver agreement for diagnosis of enterocele and rectocele depth measurements. Diagnosis

  18. Frequency dependent polarizabilities for the ground state of H2, HD, and D2

    International Nuclear Information System (INIS)

    Rychlewski, J.

    1983-01-01

    A variation-perturbation method has been employed to calculate the dynamic dipole polarizability for the ground state of the hydrogen molecule. The explicit correlated electronic wave functions were used. The averaged values of α(#betta#) and #betta#(#betta#) for several vibration-rotation states of HD and D 2 are presented. Similar values for H 2 have also been calculated and were used to test the efficiency of the method and the validity of the assumption applied in the present calculation. The agreement of the present theoretical results with the existing experimental data is found to be satisfactory

  19. Synthesis and Crystal Structure of an Unprecedented Supramolecular Complex[Co(μ2-ClO4)2(H2O)22MA

    Institute of Scientific and Technical Information of China (English)

    XU,Jing; BAI,Zhengshuai; SUN,Weiyin

    2009-01-01

    A new supramolecular framework[Co(μ2-C104)2(H2O)22MA(1)[MA=melamine(C3H6N6)]has been syn-thesized by a hydrothermal method.Interestingly,there ale inorganic and organic building blocks with two different supramolecular synthons:(a)2D(4,4)network constructed by infinite inorganic 1D chains through interchain hy-drogen bonding interactions;(b)1D zigzag organic chains formed by hydrogen bonds, which further stack up through,ππ-interactions between the two adjacent MA molecules.The entire structure of 1 is a 3D supramolecular framework resulting from the presence of abundant hydrogen bonds between infinite[CO(μ2-C1O4)2(H2O)2]n chains and zigzag MA chains in different sheets.1 gives a nice example of supramolecular framework based on non-covalent interactions including hydrogen bonding and π-π interactions.

  20. 10Gbps 2D MGC OCDMA Code over FSO Communication System

    Science.gov (United States)

    Professor Urmila Bhanja, Associate, Dr.; Khuntia, Arpita; Alamasety Swati, (Student

    2017-08-01

    Currently, wide bandwidth signal dissemination along with low latency is a leading requisite in various applications. Free space optical wireless communication has introduced as a realistic technology for bridging the gap in present high data transmission fiber connectivity and as a provisional backbone for rapidly deployable wireless communication infrastructure. The manuscript highlights on the implementation of 10Gbps SAC-OCDMA FSO communications using modified two dimensional Golomb code (2D MGC) that possesses better auto correlation, minimum cross correlation and high cardinality. A comparison based on pseudo orthogonal (PSO) matrix code and modified two dimensional Golomb code (2D MGC) is developed in the proposed SAC OCDMA-FSO communication module taking different parameters into account. The simulative outcome signifies that the communication radius is bounded by the multiple access interference (MAI). In this work, a comparison is made in terms of bit error rate (BER), and quality factor (Q) based on modified two dimensional Golomb code (2D MGC) and PSO matrix code. It is observed that the 2D MGC yields better results compared to the PSO matrix code. The simulation results are validated using optisystem version 14.