WorldWideScience

Sample records for validating precision technologies

  1. The Space Technology-7 Disturbance Reduction System Precision Control Flight Validation Experiment Control System Design

    Science.gov (United States)

    O'Donnell, James R.; Hsu, Oscar C.; Maghami, Peirman G.; Markley, F. Landis

    2006-01-01

    As originally proposed, the Space Technology-7 Disturbance Reduction System (DRS) project, managed out of the Jet Propulsion Laboratory, was designed to validate technologies required for future missions such as the Laser Interferometer Space Antenna (LISA). The two technologies to be demonstrated by DRS were Gravitational Reference Sensors (GRSs) and Colloidal MicroNewton Thrusters (CMNTs). Control algorithms being designed by the Dynamic Control System (DCS) team at the Goddard Space Flight Center would control the spacecraft so that it flew about a freely-floating GRS test mass, keeping it centered within its housing. For programmatic reasons, the GRSs were descoped from DRS. The primary goals of the new mission are to validate the performance of the CMNTs and to demonstrate precise spacecraft position control. DRS will fly as a part of the European Space Agency (ESA) LISA Pathfinder (LPF) spacecraft along with a similar ESA experiment, the LISA Technology Package (LTP). With no GRS, the DCS attitude and drag-free control systems make use of the sensor being developed by ESA as a part of the LTP. The control system is designed to maintain the spacecraft s position with respect to the test mass, to within 10 nm/the square root of Hz over the DRS science frequency band of 1 to 30 mHz.

  2. Sensing technologies for precision irrigation

    CERN Document Server

    Ćulibrk, Dubravko; Minic, Vladan; Alonso Fernandez, Marta; Alvarez Osuna, Javier; Crnojevic, Vladimir

    2014-01-01

    This brief provides an overview of state-of-the-art sensing technologies relevant to the problem of precision irrigation, an emerging field within the domain of precision agriculture. Applications of wireless sensor networks, satellite data and geographic information systems in the domain are covered. This brief presents the basic concepts of the technologies and emphasizes the practical aspects that enable the implementation of intelligent irrigation systems. The authors target a broad audience interested in this theme and organize the content in five chapters, each concerned with a specific technology needed to address the problem of optimal crop irrigation. Professionals and researchers will find the text a thorough survey with practical applications.

  3. Precision validation of MIPAS-Envisat products

    Directory of Open Access Journals (Sweden)

    C. Piccolo

    2007-01-01

    Full Text Available This paper discusses the variation and validation of the precision, or estimated random error, associated with the ESA Level 2 products from the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS. This quantity represents the propagation of the radiometric noise from the spectra through the retrieval process into the Level 2 profile values. The noise itself varies with time, steadily rising between ice decontamination events, but the Level 2 precision has a greater variation due to the atmospheric temperature which controls the total radiance received. Hence, for all species, the precision varies latitudinally/seasonally with temperature, with a small superimposed temporal structure determined by the degree of ice contamination on the detectors. The precision validation involves comparing two MIPAS retrievals at the intersections of ascending/descending orbits. For 5 days per month of full resolution MIPAS operation, the standard deviation of the matching profile pairs is computed and compared with the precision given in the MIPAS Level 2 data, except for NO2 since it has a large diurnal variation between ascending/descending intersections. Even taking into account the propagation of the pressure-temperature retrieval errors into the VMR retrieval, the standard deviation of the matching pairs is usually a factor 1–2 larger than the precision. This is thought to be due to effects such as horizontal inhomogeneity of the atmosphere and instability of the retrieval.

  4. The Development of Precise Engineering Surveying Technology

    Directory of Open Access Journals (Sweden)

    LI Guangyun

    2017-10-01

    Full Text Available With the construction of big science projects in China, the precise engineering surveying technology developed rapidly in the 21th century. Firstly, the paper summarized up the current development situation for the precise engineering surveying instrument and theory. Then the three typical cases of the precise engineering surveying practice such as accelerator alignment, industry measurement and high-speed railway surveying technology are focused.

  5. Technology on precision measurement of mass

    International Nuclear Information System (INIS)

    2005-10-01

    This book mentions mass and scales about technology for precision measurement, which deal with how to measure mass with scale. So it describes the basic things of mass and scales. It includes translated book of international standard OIML with demand of measurement and technology and form for test report and international original standard OIML with metrological and technical requirements and test report format.

  6. Precision forging technology for aluminum alloy

    Science.gov (United States)

    Deng, Lei; Wang, Xinyun; Jin, Junsong; Xia, Juchen

    2018-03-01

    Aluminum alloy is a preferred metal material for lightweight part manufacturing in aerospace, automobile, and weapon industries due to its good physical properties, such as low density, high specific strength, and good corrosion resistance. However, during forging processes, underfilling, folding, broken streamline, crack, coarse grain, and other macro- or microdefects are easily generated because of the deformation characteristics of aluminum alloys, including narrow forgeable temperature region, fast heat dissipation to dies, strong adhesion, high strain rate sensitivity, and large flow resistance. Thus, it is seriously restricted for the forged part to obtain precision shape and enhanced property. In this paper, progresses in precision forging technologies of aluminum alloy parts were reviewed. Several advanced precision forging technologies have been developed, including closed die forging, isothermal die forging, local loading forging, metal flow forging with relief cavity, auxiliary force or vibration loading, casting-forging hybrid forming, and stamping-forging hybrid forming. High-precision aluminum alloy parts can be realized by controlling the forging processes and parameters or combining precision forging technologies with other forming technologies. The development of these technologies is beneficial to promote the application of aluminum alloys in manufacturing of lightweight parts.

  7. Soviet precision timekeeping research and technology

    Energy Technology Data Exchange (ETDEWEB)

    Vessot, R.F.C.; Allan, D.W.; Crampton, S.J.B.; Cutler, L.S.; Kern, R.H.; McCoubrey, A.O.; White, J.D.

    1991-08-01

    This report is the result of a study of Soviet progress in precision timekeeping research and timekeeping capability during the last two decades. The study was conducted by a panel of seven US scientists who have expertise in timekeeping, frequency control, time dissemination, and the direct applications of these disciplines to scientific investigation. The following topics are addressed in this report: generation of time by atomic clocks at the present level of their technology, new and emerging technologies related to atomic clocks, time and frequency transfer technology, statistical processes involving metrological applications of time and frequency, applications of precise time and frequency to scientific investigations, supporting timekeeping technology, and a comparison of Soviet research efforts with those of the United States and the West. The number of Soviet professionals working in this field is roughly 10 times that in the United States. The Soviet Union has facilities for large-scale production of frequency standards and has concentrated its efforts on developing and producing rubidium gas cell devices (relatively compact, low-cost frequency standards of modest accuracy and stability) and atomic hydrogen masers (relatively large, high-cost standards of modest accuracy and high stability). 203 refs., 45 figs., 9 tabs.

  8. Soviet precision timekeeping research and technology

    International Nuclear Information System (INIS)

    Vessot, R.F.C.; Allan, D.W.; Crampton, S.J.B.; Cutler, L.S.; Kern, R.H.; McCoubrey, A.O.; White, J.D.

    1991-08-01

    This report is the result of a study of Soviet progress in precision timekeeping research and timekeeping capability during the last two decades. The study was conducted by a panel of seven US scientists who have expertise in timekeeping, frequency control, time dissemination, and the direct applications of these disciplines to scientific investigation. The following topics are addressed in this report: generation of time by atomic clocks at the present level of their technology, new and emerging technologies related to atomic clocks, time and frequency transfer technology, statistical processes involving metrological applications of time and frequency, applications of precise time and frequency to scientific investigations, supporting timekeeping technology, and a comparison of Soviet research efforts with those of the United States and the West. The number of Soviet professionals working in this field is roughly 10 times that in the United States. The Soviet Union has facilities for large-scale production of frequency standards and has concentrated its efforts on developing and producing rubidium gas cell devices (relatively compact, low-cost frequency standards of modest accuracy and stability) and atomic hydrogen masers (relatively large, high-cost standards of modest accuracy and high stability). 203 refs., 45 figs., 9 tabs

  9. Validating precision--how many measurements do we need?

    Science.gov (United States)

    ÅSberg, Arne; Solem, Kristine Bodal; Mikkelsen, Gustav

    2015-10-01

    A quantitative analytical method should be sufficiently precise, i.e. the imprecision measured as a standard deviation should be less than the numerical definition of the acceptable standard deviation. We propose that the entire 90% confidence interval for the true standard deviation shall lie below the numerical definition of the acceptable standard deviation in order to assure that the analytical method is sufficiently precise. We also present power function curves to ease the decision on the number of measurements to make. Computer simulation was used to calculate the probability that the upper limit of the 90% confidence interval for the true standard deviation was equal to or exceeded the acceptable standard deviation. Power function curves were constructed for different scenarios. The probability of failure to assure that the method is sufficiently precise increases with decreasing number of measurements and with increasing standard deviation when the true standard deviation is well below the acceptable standard deviation. For instance, the probability of failure is 42% for a precision experiment of 40 repeated measurements in one analytical run and 7% for 100 repeated measurements, when the true standard deviation is 80% of the acceptable standard deviation. Compared to the CLSI guidelines, validating precision according to the proposed principle is more reliable, but demands considerably more measurements. Using power function curves may help when planning studies to validate precision.

  10. Laser technology for high precision satellite tracking

    Science.gov (United States)

    Plotkin, H. H.

    1974-01-01

    Fixed and mobile laser ranging stations have been developed to track satellites equipped with retro-reflector arrays. These have operated consistently at data rates of once per second with range precision better than 50 cm, using Q-switched ruby lasers with pulse durations of 20 to 40 nanoseconds. Improvements are being incorporated to improve the precision to 10 cm, and to permit ranging to more distant satellites. These include improved reflector array designs, processing and analysis of the received reflection pulses, and use of sub-nanosecond pulse duration lasers.

  11. Integrated aerospace technologies in precision agriculture support

    International Nuclear Information System (INIS)

    Borfecchia, F.; De Cecco, L.; Martini, S.; Giordano, L.; Trotta, C.; Masci, D.; Di Gioia, V.; Pignatelli, V.; Micheli, C.; Moreno, A.; Taraglio, S.; Nanni, V.; Moriconi, Cl.; Mancini, S.; Pizzuti, A.; Picciucco, P.

    2015-01-01

    In a scenery where agriculture plays a more and more 'decisive and strategic role, the spread, in that sector, of aerospace and advanced robotic technology, more and more' accessible, meets the needs of basing decisions on integrated information, not only for increase production, but also to ensure food quality 'to the world population, minimizing the environmental impacts and climatic problems, and enhancing biodiversity'. [it

  12. Alternative Solvents and Technologies for Precision Cleaning of Aerospace Components

    Science.gov (United States)

    Grandelli, Heather; Maloney, Phillip; DeVor, Robert; Hintze, Paul

    2014-01-01

    Precision cleaning solvents for aerospace components and oxygen fuel systems, including currently used Vertrel-MCA, have a negative environmental legacy, high global warming potential, and have polluted cleaning sites. Thus, alternative solvents and technologies are being investigated with the aim of achieving precision contamination levels of less than 1 mg/sq ft. The technologies being evaluated are ultrasonic bath cleaning, plasma cleaning and supercritical carbon dioxide cleaning.

  13. Recent Advances in Precision Machinery and Manufacturing Technology

    DEFF Research Database (Denmark)

    Liu, Chien-Hung; Hsieh, Wen-Hsiang; Chang, Zong-Yu

    2014-01-01

    Precision machinery and manufacturing technology are be- coming more important in current and future technologies. New knowledge in this field will aid in the advancement of various technologies that are needed to gain industrial competitiveness. To this end, the special issue aims to disseminate...... the latest advancements of relevant fundamental and applied research works of high quality to the inter- national community. The topics of the accepted articles in the special issue include precision manufacturing pro- cesses, measurements and control, robotics and automation, machine tools, advanced...

  14. Technology in precision viticulture: a state of the art review

    Directory of Open Access Journals (Sweden)

    Matese A

    2015-05-01

    Full Text Available Alessandro Matese,1 Salvatore Filippo Di Gennaro1,2 1Institute of Biometeorology, National Research Council (IBIMET-CNR, Florence, Italy; 2Department of Agricultural, Food and Environmental Sciences, University of Perugia, Perugia, Italy Abstract: Precision viticulture aims to maximize the oenological potential of vineyards. This is especially true in regions where the high quality standards of wine production justify the adoption of site-specific management practices to simultaneously increase both quality and yield. The introduction of new technologies for supporting vineyard management allows the efficiency and quality of production to be improved and, at the same time, reduces the environmental impact. The rapid evolution of information communication technologies and geographical science offers enormous potential for the development of optimized solutions for distributed information for precision viticulture. Recent technological developments have allowed useful tools to be elaborated that help in the monitoring and control of many aspects of vine growth. Precision viticulture thus seeks to exploit the widest range of available observations to describe the vineyard spatial variability with high resolution, and provide recommendations to improve management efficiency in terms of quality, production, and sustainability. This review presents a brief outline of state of the art of technologies in precision viticulture. It is divided in two sections, the first focusing on monitoring technologies such as geolocating and remote and proximal sensing; the second focuses on variable-rate technologies and the new agricultural robots. Keywords: remote sensing, proximal sensing, variable-rate technology, robot 

  15. Advances in precision machining and moulding technology bring design opportunities.

    Science.gov (United States)

    Glendening, Paul

    2008-09-01

    Machining of materials for medical applications has moved to a new level of precision. In parallel with this, moulding technology has improved through the increased use of sensors in moulds, enhanced design simulation and processes such as micromoulding. This article examines the opportunities offered by these developments and includes examples of mass produced parts that demonstrate the new capabilities useful to product designers.

  16. Precise stacking and bonding technology for RDDS structure

    International Nuclear Information System (INIS)

    Higo, T; Toge, N.; Suzuki, T.

    2000-01-01

    The X-band accelerating structures called RDDS1 (Rounded Dumped Detuned Structure) for the linear collider have been developed. The main body of RDDS1 was successfully fabricated in Japan (KEK, IHI). We established basic fabrication techniques through the development of prototype structures including RDDS1. The precise stacking and bonding technologies for RDDS structure are presented in this paper. (author)

  17. Technological advances in precision medicine and drug development.

    Science.gov (United States)

    Maggi, Elaine; Patterson, Nicole E; Montagna, Cristina

    New technologies are rapidly becoming available to expand the arsenal of tools accessible for precision medicine and to support the development of new therapeutics. Advances in liquid biopsies, which analyze cells, DNA, RNA, proteins, or vesicles isolated from the blood, have gained particular interest for their uses in acquiring information reflecting the biology of tumors and metastatic tissues. Through advancements in DNA sequencing that have merged unprecedented accuracy with affordable cost, personalized treatments based on genetic variations are becoming a real possibility. Extraordinary progress has been achieved in the development of biological therapies aimed to even further advance personalized treatments. We provide a summary of current and future applications of blood based liquid biopsies and how new technologies are utilized for the development of biological therapeutic treatments. We discuss current and future sequencing methods with an emphasis on how technological advances will support the progress in the field of precision medicine.

  18. Precision Spectroscopy, Diode Lasers, and Optical Frequency Measurement Technology

    Science.gov (United States)

    Hollberg, Leo (Editor); Fox, Richard (Editor); Waltman, Steve (Editor); Robinson, Hugh

    1998-01-01

    This compilation is a selected set of reprints from the Optical Frequency Measurement Group of the Time and Frequency Division of the National Institute of Standards and Technology, and consists of work published between 1987 and 1997. The two main programs represented here are (1) development of tunable diode-laser technology for scientific applications and precision measurements, and (2) research toward the goal of realizing optical-frequency measurements and synthesis. The papers are organized chronologically in five, somewhat arbitrarily chosen categories: Diode Laser Technology, Tunable Laser Systems, Laser Spectroscopy, Optical Synthesis and Extended Wavelength Coverage, and Multi-Photon Interactions and Optical Coherences.

  19. Applications of Laser Precisely Processing Technology in Solar Cells

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    According to the design method of laser resonator cavity, we optimized the primary parameters of resonator and utilized LD arrays symmetrically pumping manner to implementing output of the high-brightness laser in our laser cutter, then which was applied to precisely cutting the conductive film of CuInSe2 solar cells, the buried contact silicon solar cells' electrode groove, and perforating in wafer which is used to the emitter wrap through silicon solar cells. Laser processing precision was less than 40μm, the results have met solar cell's fabrication technology, and made finally the buried cells' conversion efficiency be improved from 18% to 21% .

  20. Application of high precision temperature control technology in infrared testing

    Science.gov (United States)

    Cao, Haiyuan; Cheng, Yong; Zhu, Mengzhen; Chu, Hua; Li, Wei

    2017-11-01

    In allusion to the demand of infrared system test, the principle of Infrared target simulator and the function of the temperature control are presented. The key technology of High precision temperature control is discussed, which include temperature gathering, PID control and power drive. The design scheme of temperature gathering is put forward. In order to reduce the measure error, discontinuously current and four-wire connection for the platinum thermal resistance are adopted. A 24-bits AD chip is used to improve the acquisition precision. Fuzzy PID controller is designed because of the large time constant and continuous disturbance of the environment temperature, which result in little overshoot, rapid response, high steady-state accuracy. Double power operational amplifiers are used to drive the TEC. Experiments show that the key performances such as temperature control precision and response speed meet the requirements.

  1. Cold rolling precision forming of shaft parts theory and technologies

    CERN Document Server

    Song, Jianli; Li, Yongtang

    2017-01-01

    This book presents in detail the theory, processes and equipment involved in cold rolling precision forming technologies, focusing on spline and thread shaft parts. The main topics discussed include the status quo of research on cold rolling precision forming technologies; the design and calculation of process parameters; the numerical simulation of cold rolling forming processes; and the equipment used in cold rolling forming. The mechanism of cold rolling forming is extremely complex, and research on the processes, theory and mechanical analysis of spline cold rolling forming has remained very limited to date. In practice, the forming processes and production methods used are mainly chosen on the basis of individual experience. As such, there is a marked lack of both systematic, theory-based guidelines, and of specialized books covering theoretical analysis, numerical simulation, experiments and equipment used in spline cold rolling forming processes – all key points that are included in this book and ill...

  2. Application of precise MPD & pressure balance cementing technology

    Directory of Open Access Journals (Sweden)

    Yong Ma

    2018-03-01

    Full Text Available The precise managed pressure drilling (MPD technology is mainly used to deal with the difficulties encountered when oil and gas open hole sections with multiple pressure systems and the strata with narrow safety density window are drilled through. If its liner cementing is carried out according to the conventional method, lost circulation is inevitable in the process of cementing while the displacement efficiency of small-clearance liner cementing is satisfied. If the positive and inverse injection technology is adopted, the cementing quality cannot meet the requirements of later well test engineering of ultradeep wells. In this paper, the cementing operation of Ø114.3 mm liner in Well Longgang 70 which was drilled in the Jiange structure of the Sichuan Basin was taken as an example to explore the application of the cementing technology based on the precise MPD and pressure balancing method to the cementing of long open-hole sections (as long as 859 m with both high and low pressures running through multiple reservoirs. On the one hand, the technical measures were taken specifically to ensure the annulus filling efficiency of slurry and the pressure balance in the whole process of cementing. And on the other hand, the annulus pressure balance was precisely controlled by virtue of precise MPD devices and by injecting heavy weight drilling fluids through central pipes, and thus the wellbore pressure was kept steady in the whole process of cementing in the strata with narrow safety density window. It is indicated that Ø114.3 mm liner cementing in this well is good with qualified pressure tests and no channeling emerges at a funnel during the staged density reduction. It is concluded that this method can enhance the liner cementing quality of complex ultradeep gas wells and improve the wellbore conditions for the later safe well tests of high-pressure gas wells. Keywords: Ultradeep well, Liner cementing, Narrow safety density window, Precise

  3. Innovations in precision seed drilling technology: successes or failures?

    Directory of Open Access Journals (Sweden)

    Johannes Benninger

    2016-06-01

    Full Text Available In view of the development of various technological alternatives in precision seed drilling, it has become a matter of research whether there are clear criteria for the success or failure of technological innovations. Around the turn to the 20th century, two very different precision seed drill methods were developed almost at the same time. Band seeding made it possible to achieve nearly perfect single grain sowing. For this purpose, individual, equally spaced seeds were embedded into bands of paper or cotton. In the field, these seed tapes were then unreeled from large drums. The pneumatic system proposed in 1897, by contrast, introduced grain singling using a vacuum for the first time. Although band seeding presented a satisfactory technological solution, it was never widely applied. Pneumatic systems, on the other hand, took long to catch on and only started to be successful in the late 1960s. Up to then, these innovative systems had to be considered as failures. Changing the period under review, however, may completely reverse the assessment of whether an innovation is a success or a failure.

  4. Precision gravity measurement utilizing Accelerex vibrating beam accelerometer technology

    Science.gov (United States)

    Norling, Brian L.

    Tests run using Sundstrand vibrating beam accelerometers to sense microgravity are described. Lunar-solar tidal effects were used as a highly predictable signal which varies by approximately 200 billionths of the full-scale gravitation level. Test runs of 48-h duration were used to evaluate stability, resolution, and noise. Test results on the Accelerex accelerometer show accuracies suitable for precision applications such as gravity mapping and gravity density logging. The test results indicate that Accelerex technology, even with an instrument design and signal processing approach not optimized for microgravity measurement, can achieve 48-nano-g (1 sigma) or better accuracy over a 48-h period. This value includes contributions from instrument noise and random walk, combined bias and scale factor drift, and thermal modeling errors as well as external contributions from sampling noise, test equipment inaccuracies, electrical noise, and cultural noise induced acceleration.

  5. Present situation and trend of precision guidance technology and its intelligence

    Science.gov (United States)

    Shang, Zhengguo; Liu, Tiandong

    2017-11-01

    This paper first introduces the basic concepts of precision guidance technology and artificial intelligence technology. Then gives a brief introduction of intelligent precision guidance technology, and with the help of development of intelligent weapon based on deep learning project in foreign: LRASM missile project, TRACE project, and BLADE project, this paper gives an overview of the current foreign precision guidance technology. Finally, the future development trend of intelligent precision guidance technology is summarized, mainly concentrated in the multi objectives, intelligent classification, weak target detection and recognition, intelligent between complex environment intelligent jamming and multi-source, multi missile cooperative fighting and other aspects.

  6. Measuring Constructs in Family Science: How Can Item Response Theory Improve Precision and Validity?

    Science.gov (United States)

    Gordon, Rachel A.

    2015-01-01

    This article provides family scientists with an understanding of contemporary measurement perspectives and the ways in which item response theory (IRT) can be used to develop measures with desired evidence of precision and validity for research uses. The article offers a nontechnical introduction to some key features of IRT, including its…

  7. Statistical inference for the within-device precision of quantitative measurements in assay validation.

    Science.gov (United States)

    Liu, Jen-Pei; Lu, Li-Tien; Liao, C T

    2009-09-01

    Intermediate precision is one of the most important characteristics for evaluation of precision in assay validation. The current methods for evaluation of within-device precision recommended by the Clinical Laboratory Standard Institute (CLSI) guideline EP5-A2 are based on the point estimator. On the other hand, in addition to point estimators, confidence intervals can provide a range for the within-device precision with a probability statement. Therefore, we suggest a confidence interval approach for assessment of the within-device precision. Furthermore, under the two-stage nested random-effects model recommended by the approved CLSI guideline EP5-A2, in addition to the current Satterthwaite's approximation and the modified large sample (MLS) methods, we apply the technique of generalized pivotal quantities (GPQ) to derive the confidence interval for the within-device precision. The data from the approved CLSI guideline EP5-A2 illustrate the applications of the confidence interval approach and comparison of results between the three methods. Results of a simulation study on the coverage probability and expected length of the three methods are reported. The proposed method of the GPQ-based confidence intervals is also extended to consider the between-laboratories variation for precision assessment.

  8. High precision 3D coordinates location technology for pellet

    International Nuclear Information System (INIS)

    Fan Yong; Zhang Jiacheng; Zhou Jingbin; Tang Jun; Xiao Decheng; Wang Chuanke; Dong Jianjun

    2010-01-01

    In inertial confinement fusion (ICF) system, manual way has been used to collimate the pellet traditionally, which is time-consuming and low-level automated. A new method based on Binocular Vision is proposed, which can place the prospecting apparatus on the public diagnosis platform to reach relevant engineering target and uses the high precision two dimension calibration board. Iterative method is adopted to satisfy 0.1 pixel for corner extraction precision. Furthermore, SVD decomposition is used to remove the singularity corners and advanced Zhang's calibration method is applied to promote camera calibration precision. Experiments indicate that the RMS of three dimension coordinate measurement precision is 25 μm, and the max system RMS of distance measurement is better than 100 μm, satisfying the system index requirement. (authors)

  9. Fuel Cell and Hydrogen Technology Validation | Hydrogen and Fuel Cells |

    Science.gov (United States)

    NREL Fuel Cell and Hydrogen Technology Validation Fuel Cell and Hydrogen Technology Validation The NREL technology validation team works on validating hydrogen fuel cell electric vehicles; hydrogen fueling infrastructure; hydrogen system components; and fuel cell use in early market applications such as

  10. Discovery Mondays "State-of-the-art technologies for precision"

    CERN Multimedia

    2007-01-01

    Ceramic plate drilled with high precision in CERN’s workshop. The diameter of each hole is only 0.02 millimetres, comparable to the diameter of a hair.Scientists have to be infinitely precise to study the infinitely small. Thus, even though the LHC is the world’s largest accelerator, it has to be aligned to within a tenth of a millimetre. The detectors weigh several thousand tonnes but are capable of detecting the tiniest vibration of the Earth. Join us at the next Discovery Monday to find out about CERN’s state-of-the-art tools for achieving the degrees of resolution required in the field of particle physics. Don’t miss this opportunity to discover the world of precision! The event will be conducted in FrenchCome along to the Microcosm (Reception Building 33, Meyrin site) on Monday 5 November from 7.30 p.m. to 9.00 p.m. Entrance Free http://www.cern.ch/LundisDecouverte/

  11. EDITORIAL: Precision Measurement Technology at the 56th International Scientific Colloquium in Ilmenau Precision Measurement Technology at the 56th International Scientific Colloquium in Ilmenau

    Science.gov (United States)

    Manske, E.; Froehlich, T.

    2012-07-01

    The 56th International Scientific Colloquium was held from 12th to 16th September 2011 at the Ilmenau University of Technology in Germany. This event was organized by the Faculty of Mechanical Engineering under the title: 'Innovation in Mechanical Engineering—Shaping the Future' and was intended to reflect the entire scope of modern mechanical engineering. In three main topics many research areas, all involving innovative mechanical engineering, were addressed, especially in the fields of Precision Engineering and Precision Measurement Technology, Mechatronics and Ambient-Assisted Living and Systems Technology. The participants were scientists from 21 countries, and 166 presentations were given. This special issue of Measurement Science and Technology presents selected contributions on 'Precision Engineering and Precision Measurement Technology'. Over three days the conference participants discussed novel scientific results in two sessions. The main topics of these sessions were: Measurement and Sensor Technology Process measurement Laser measurement Force measurement Weighing technology Temperature measurement Measurement dynamics and Nanopositioning and Nanomeasuring Technology Nanopositioning and nanomeasuring machines Nanometrology Probes and tools Mechanical design Signal processing Control and visualization in NPM devices Significant research results from the Collaborative Research Centre SFB 622 'Nanopositioning and Nanomeasuring Machines' funded by the German Research Foundation (DFG) were presented as part of this topic. As the Chairmen, our special thanks are due to the International Programme Committee, the Organization Committee and the conference speakers as well as colleagues from the Institute of Process Measurement and Sensor Technology who helped make the conference a success. We would like to thank all the authors for their contributions, the referees for their time spent reviewing the contributions and their valuable comments, and the whole

  12. Transactions on the Precision and Electronic Technology. Vol. 4

    International Nuclear Information System (INIS)

    1999-01-01

    The conference covers most important subjects connected with application of electronic technologies for resistors, sensors, radiation detectors and other microelectronic structures. The investigations of physical properties (electrical and magnetic properties, crystal structure etc.) of interest materials have been also presented

  13. Validation of precision powder injection molding process simulations using a spiral test geometry

    DEFF Research Database (Denmark)

    Marhöfer, Maximilian; Müller, Tobias; Tosello, Guido

    2015-01-01

    Like in many other areas of engineering, process simulations find application in precision injection molding to assist and optimize the quality and design of precise products and the molding process. Injection molding comprises mainly the manufacturing of plastic components. However, the variant ....... The necessary data and the implementation procedure of the new material models are outlined. In order to validate the simulation studies and evaluate their accuracy, the simulation results are compared with experiments performed using a spiral test geometry...... for powder injection molding. This characterization includes measurements of rheological, thermal, and pvT behavior of the powder-binder-mixes. The acquired material data was used to generate new material models for the database of the commercially available Autodesk Moldflow® simulation software...

  14. Innovation, productivity, and pricing: Capturing value from precision medicine technology in Canada.

    Science.gov (United States)

    Emery, J C Herbert; Zwicker, Jennifer D

    2017-07-01

    For new technology and innovation such as precision medicine to become part of the solution for the fiscal sustainability of Canadian Medicare, decision-makers need to change how services are priced rather than trying to restrain emerging technologies like precision medicine for short-term cost savings. If provincial public payers shift their thinking to be public purchasers, value considerations would direct reform of the reimbursement system to have prices that adjust with technologically driven productivity gains. This strategic shift in thinking is necessary if Canadians are to benefit from the promised benefits of innovations like precision medicine.

  15. Precision medicine, an approach for development of the future medicine technologies

    Directory of Open Access Journals (Sweden)

    Iraj Nabipour

    2016-04-01

    Full Text Available Precision medicine is an approach in medicine that takes into account individual differences in people's genes, environments, and lifestyle. This field of medicine redefines our understanding of disease onset and progression, treatment response, and health outcomes through the more precise measurement of molecular, environmental, and behavioral factors that contribute to health and disease. Undoubtedly, the advances in omics technologies including genomics, data collection and storage, computational analysis, and mobile health applications over the last decade produced significant progress for precision medicine. In fact, precision medicine is a platform for the growth of personalized medicine, wearable biosensors, mobile health, computational sciences, genomic singularity, and other omics technologies. In the pathway of precision medicine, mathematics and computational sciences will be revolutionized to overcome the challenges in Big Data. By the birth of precision medicine, novel therapeutic strategies for chronic complex diseases such as cardiovascular disease and cancers would be designed in Systems Medicine.

  16. Validation of the Information/Communications Technology Literacy Test

    Science.gov (United States)

    2016-10-01

    Technical Report 1360 Validation of the Information /Communications Technology Literacy Test D. Matthew Trippe Human Resources Research...TITLE AND SUBTITLE Validation of the Information /Communications Technology Literacy Test 5a. CONTRACT OR GRANT NUMBER W91WAS-09-D-0013 5b...validate a measure of cyber aptitude, the Information /Communications Technology Literacy Test (ICTL), in predicting trainee performance in Information

  17. Old and new technologies provide dynamic precise positioning

    International Nuclear Information System (INIS)

    Dano, P.K.

    1987-01-01

    Vehicle's coordinates are available for both reporting and operator use utilizing passive survey techniques and equipments with excellent results thus freeing up and protecting the vehicle reporting transmitters. Use of spread spectrum radiolocation offers real-time extraction and correction of system biases eliminating fixed timing errors. An unlimited number of users may receive differential signals as well as system description data in such a manner as to facilitate complete ''blind'' entry into the system while attaining full operational capability. Utilizing a proprietary technique, the passive user obtains additional lines of position as well as calibration information while using the traditional number of reference stations. A single frequency could be used world-wide since ''networks'' are identified by code. Adjacent networks can be indicated to the receiver using the system description data thus facilitating network to network operation without operator intervention. Although the system accuracy is excellent for survey, the automation of dynamic precise positioning is most advantageous in vehicle location

  18. NDE reliability and advanced NDE technology validation

    International Nuclear Information System (INIS)

    Doctor, S.R.; Deffenbaugh, J.D.; Good, M.S.; Green, E.R.; Heasler, P.G.; Hutton, P.H.; Reid, L.D.; Simonen, F.A.; Spanner, J.C.; Vo, T.V.

    1989-01-01

    This paper reports on progress for three programs: (1) evaluation and improvement in nondestructive examination reliability for inservice inspection of light water reactors (LWR) (NDE Reliability Program), (2) field validation acceptance, and training for advanced NDE technology, and (3) evaluation of computer-based NDE techniques and regional support of inspection activities. The NDE Reliability Program objectives are to quantify the reliability of inservice inspection techniques for LWR primary system components through independent research and establish means for obtaining improvements in the reliability of inservice inspections. The areas of significant progress will be described concerning ASME Code activities, re-analysis of the PISC-II data, the equipment interaction matrix study, new inspection criteria, and PISC-III. The objectives of the second program are to develop field procedures for the AE and SAFT-UT techniques, perform field validation testing of these techniques, provide training in the techniques for NRC headquarters and regional staff, and work with the ASME Code for the use of these advanced technologies. The final program's objective is to evaluate the reliability and accuracy of interpretation of results from computer-based ultrasonic inservice inspection systems, and to develop guidelines for NRC staff to monitor and evaluate the effectiveness of inservice inspections conducted on nuclear power reactors. This program started in the last quarter of FY89, and the extent of the program was to prepare a work plan for presentation to and approval from a technical advisory group of NRC staff

  19. Precision Airdrop Technology Conference and Demonstration (4th) 2007

    Science.gov (United States)

    2008-02-01

    items such as towplates, CDS buffer stop assemblies/center vertical restrain systems , C-17 Dual Row Airdrop System platforms, and outrigger ...specialized areas such as control systems , launcher structures , instruments, solar arrays, real-time simulation software, and parachute systems . Dutch...expertise range from advanced materials, structural composites, electronics, informatics, and portable power systems . TSI technologies are used in

  20. Precision Membrane Optical Shell (PMOS) Technology for Lightweight LIDAR Apertures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Precision membrane optical shell (PMOS) technology is an innovative combination of 1) ultra lightweight optically smooth membrane thin films, 2) advanced mold based...

  1. Development of technology on natural flaw fabrication and precise diagnosis for the major components in NPPs

    International Nuclear Information System (INIS)

    Han, Jung Ho; Choi, Myung Sik; Lee, Doek Hyun; Hur, Do Haeng

    2002-01-01

    The objective of this research is to develop a fabrication technology of natural flaw specimen of major components in NPPs and a technology of precise diagnosis for failure and degradation of components using natural flaw specimen. 1) Successful development of the natural flaw fabrication technology of SG tube 2) Evaluation of ECT signal and development of precise diagnosis using natural flaws. - Determination of length, depth, width, and multiplicity of fabricated natural flaws. - Informations about detectability and accuracy of ECT evaluation on various kinds of defects are collected when the combination of probe and frequency is changed. - An advanced technology for precise ECT evaluation is established. 3) Application of precise ECT diagnosis to failure analysis of SG tube in operation. - Fretting wear of KSNP SG. - ODSCC at tube expanded region of KSNP SG. - Determination of through/non-through wall of axial crack

  2. integrated aerospace technologies in support of precision agriculture

    International Nuclear Information System (INIS)

    Borfecchia, Flavio; De Cecco, Luigi; Martini, Sandro

    2015-01-01

    In a scenario where agriculture plays a role increasingly important and strategic, dissemination, in this field, these space technologies and advanced robotic, more and more accessible, responds We need to base decisions on information integrated, not only to increase the production, but also to ensure quality food to the people World, minimizing environmental impacts and climate, and enhancing biodiversity. In this context, applications based on these technologies are proving increasingly central role in tackling the challenges of productivity increase in agriculture required by the global market, with a view Environmental sustainability also focused on diffusion of green economy and circular, in which refer some of the experimental applications and on April conducted in ENEA. [it

  3. Intelligent technologies in process of highly-precise products manufacturing

    Science.gov (United States)

    Vakhidova, K. L.; Khakimov, Z. L.; Isaeva, M. R.; Shukhin, V. V.; Labazanov, M. A.; Ignatiev, S. A.

    2017-10-01

    One of the main control methods of the surface layer of bearing parts is the eddy current testing method. Surface layer defects of bearing parts, like burns, cracks and some others, are reflected in the results of the rolling surfaces scan. The previously developed method for detecting defects from the image of the raceway was quite effective, but the processing algorithm is complicated and lasts for about 12 ... 16 s. The real non-stationary signals from an eddy current transducer (ECT) consist of short-time high-frequency and long-time low-frequency components, therefore a transformation is used for their analysis, which provides different windows for different frequencies. The wavelet transform meets these conditions. Based on aforesaid, a methodology for automatically detecting and recognizing local defects in bearing parts surface layer has been developed on the basis of wavelet analysis using integral estimates. Some of the defects are recognized by the amplitude component, otherwise an automatic transition to recognition by the phase component of information signals (IS) is carried out. The use of intelligent technologies in the manufacture of bearing parts will, firstly, significantly improve the quality of bearings, and secondly, significantly improve production efficiency by reducing (eliminating) rejections in the manufacture of products, increasing the period of normal operation of the technological equipment (inter-adjustment period), the implementation of the system of Flexible facilities maintenance, as well as reducing production costs.

  4. Validated biomarkers: The key to precision treatment in patients with breast cancer.

    Science.gov (United States)

    Duffy, Michael J; O'Donovan, Norma; McDermott, Enda; Crown, John

    2016-10-01

    Recent DNA sequencing and gene expression studies have shown that at a molecular level, almost every case of breast cancer is unique and different from other breast cancers. For optimum management therefore, every patient should receive treatment that is guided by the molecular composition of their tumor, i.e., precision treatment. While such a scenario is still some distance into the future, biomarkers are beginning to play an important role in preparing the way for precision treatment. In particular, biomarkers are increasingly being used for predicting patient outcome and informing as to the most appropriate type of systemic therapy to be administered. Mandatory biomarkers for every newly diagnosed case of breast cancer are estrogen receptors and progesterone receptors in selecting patients for endocrine treatment and HER2 for identifying patients likely to benefit from anti-HER2 therapy. Amongst the best validated prognostic biomarker tests are uPA/PAI-1, MammaPrint and Oncotype DX. Although currently, there are no biomarkers available for predicting response to specific forms of chemotherapy, uPA/PAI-1 and Oncotype DX can aid the identification of lymph node-negative patients that are most likely to benefit from adjuvant chemotherapy, in general. In order to accelerate progress towards precision treatment for women with breast cancer, we need additional predictive biomarkers, especially for enhancing the positive predictive value for endocrine and anti-HER2 therapies, as well as biomarkers for predicting response to specific forms of chemotherapy. The ultimate biomarker test for achieving the goal of precision treatment for patients with breast cancer will likely require a combination of gene sequencing and transcriptomic analysis of every patient's tumor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. TECHNICAL AND TECHNOLOGICAL ASPECTS IN PLANT PROTECTION IN THE PRECISION FARMING SYSTEM

    Directory of Open Access Journals (Sweden)

    Mladen Jurišić

    2015-06-01

    Full Text Available The basic premise of precision farming as a larger amount of information is its availability to the farmer in making decision. Direct comparison of perennial parameters obtained from the plot results in purposefully, argumentative and optimal use of resources for work (while keeping in mind the ecological impact. Today, the development of satellite navigation technology and monitoring of agricultural machinery, and reducing the cost of these devices again revived the question of the precision agriculture application. Advanced farmers in developed agricultural countries already regularly apply some of the technological possibilities of precision farming. Precision agriculture and plant protection allow the farmer realizing high incomes while keeping safe natural resources. Using modern GIS technology machines collect data directly from the plot using sensors and integrate themselves into the data processing system. Processed information is used by a farmer taking GreenStar system for the new planned operation and achieving significant time and money spare. Precision agriculture offers the possibility of optimal care of each plant, not just the average, or the entire field. Low risk investments are one of the main factors of choice precise plant protection. The use of pilotless aircrafts remote sensing allow fast and economical obtaining data and sufficient precision information. Using modern technology such as Variable Rate Application (applying a variable volume and GreenStar software package it is possible to regulate the amount of care and protection.

  6. Dairy farmers with larger herd sizes adopt more precision dairy technologies.

    Science.gov (United States)

    Gargiulo, J I; Eastwood, C R; Garcia, S C; Lyons, N A

    2018-06-01

    An increase in the average herd size on Australian dairy farms has also increased the labor and animal management pressure on farmers, thus potentially encouraging the adoption of precision technologies for enhanced management control. A survey was undertaken in 2015 in Australia to identify the relationship between herd size, current precision technology adoption, and perception of the future of precision technologies. Additionally, differences between farmers and service providers in relation to perception of future precision technology adoption were also investigated. Responses from 199 dairy farmers, and 102 service providers, were collected between May and August 2015 via an anonymous Internet-based questionnaire. Of the 199 dairy farmer responses, 10.4% corresponded to farms that had fewer than 150 cows, 37.7% had 151 to 300 cows, 35.5% had 301 to 500 cows; 6.0% had 501 to 700 cows, and 10.4% had more than 701 cows. The results showed that farmers with more than 500 cows adopted between 2 and 5 times more specific precision technologies, such as automatic cup removers, automatic milk plant wash systems, electronic cow identification systems and herd management software, when compared with smaller farms. Only minor differences were detected in perception of the future of precision technologies between either herd size or farmers and service providers. In particular, service providers expected a higher adoption of automatic milking and walk over weighing systems than farmers. Currently, the adoption of precision technology has mostly been of the type that reduces labor needs; however, respondents indicated that by 2025 adoption of data capturing technology for monitoring farm system parameters would be increased. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Precise Geolocation Of Persistent Scatterers Aided And Validated By Lidar DSM

    Science.gov (United States)

    Chang, Ling; Dheenathayalan, Prabu; Hanessen, Ramon

    2013-12-01

    Persistent Scatterers (PS) interferometry results in the de- formation history of time-coherent scatterers. Although several applications focus on smooth, spatially correlated signals, we aim for the detection, identification and analysis of single anomalies. These targets can be indicative of, e.g., strain in structures, potentially leading to the failure of such structures. For the identification and analysis it is of the greatest importance to know the exact position of the effective scattering center, to avoid an improper interpretation of the driving mechanism. Here we present an approach to optimize the geolocation of important scatterers, when necessary aided by an a priori Lidar-derived DSM (AHN-1 data) with 15cm and 5m resolution in vertical and horizontal directions, respectively. The DSM is also used to validate the geocoding. We implement our approach on a near-collapse event of a shopping mall in Heerlen, the Netherlands, to generate the precise geolocation of local PS points.

  8. Research on the high-precision non-contact optical detection technology for banknotes

    Science.gov (United States)

    Jin, Xiaofeng; Liang, Tiancai; Luo, Pengfeng; Sun, Jianfeng

    2015-09-01

    The technology of high-precision laser interferometry was introduced for optical measurement of the banknotes in this paper. Taking advantage of laser short wavelength and high sensitivity, information of adhesive tape and cavity about the banknotes could be checked efficiently. Compared with current measurement devices, including mechanical wheel measurement device, Infrared measurement device, ultrasonic measurement device, the laser interferometry measurement has higher precision and reliability. This will improve the ability of banknotes feature information in financial electronic equipment.

  9. Precision linac and laser technologies for nuclear photonics gamma-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F.; Hartemann, F. V.; Anderson, S. G.; Cross, R. R.; Gibson, D. J.; Hall, J.; Marsh, R. A.; Messerly, M.; Wu, S. S.; Siders, C. W.; Barty, C. P. J. [Lawrence Livermore National Laboratory, NIF and Photon Science, 7000 East Avenue, Livermore, California 94550 (United States)

    2012-05-15

    Tunable, high precision gamma-ray sources are under development to enable nuclear photonics, an emerging field of research. This paper focuses on the technological and theoretical challenges related to precision Compton scattering gamma-ray sources. In this scheme, incident laser photons are scattered and Doppler upshifted by a high brightness electron beam to generate tunable and highly collimated gamma-ray pulses. The electron and laser beam parameters can be optimized to achieve the spectral brightness and narrow bandwidth required by nuclear photonics applications. A description of the design of the next generation precision gamma-ray source currently under construction at Lawrence Livermore National Laboratory is presented, along with the underlying motivations. Within this context, high-gradient X-band technology, used in conjunction with fiber-based photocathode drive laser and diode pumped solid-state interaction laser technologies, will be shown to offer optimal performance for high gamma-ray spectral flux, narrow bandwidth applications.

  10. Precision farming - Technology assessment of site-specific input application in cereals

    DEFF Research Database (Denmark)

    Pedersen, Søren Marcus

    economic and socio-economic analysis. The current status of precision farming in Denmark is as follows: • The technology is primarily applicable for large farm holdings • Economic viability depends on site-specific yield variation • So far, the business economic benefits from most PF-practices are modest...... but it seems possible to obtain a socio-economic benefits from lime, variable rate herbicide and possibly nitrogen application • The technology may improve farm logistics, planning and crop quality (e.g. protein content) - but • The costs of implementing PF-practices are high and • Technical functionality...... several years before the next generation of precision farming systems will be available in practice. Meanwhile, those farmers who already have invested in yield monitors and soil analysis for precision farming should be able to use the current technology in the best possible way....

  11. Deterministic ion beam material adding technology for high-precision optical surfaces.

    Science.gov (United States)

    Liao, Wenlin; Dai, Yifan; Xie, Xuhui; Zhou, Lin

    2013-02-20

    Although ion beam figuring (IBF) provides a highly deterministic method for the precision figuring of optical components, several problems still need to be addressed, such as the limited correcting capability for mid-to-high spatial frequency surface errors and low machining efficiency for pit defects on surfaces. We propose a figuring method named deterministic ion beam material adding (IBA) technology to solve those problems in IBF. The current deterministic optical figuring mechanism, which is dedicated to removing local protuberances on optical surfaces, is enriched and developed by the IBA technology. Compared with IBF, this method can realize the uniform convergence of surface errors, where the particle transferring effect generated in the IBA process can effectively correct the mid-to-high spatial frequency errors. In addition, IBA can rapidly correct the pit defects on the surface and greatly improve the machining efficiency of the figuring process. The verification experiments are accomplished on our experimental installation to validate the feasibility of the IBA method. First, a fused silica sample with a rectangular pit defect is figured by using IBA. Through two iterations within only 47.5 min, this highly steep pit is effectively corrected, and the surface error is improved from the original 24.69 nm root mean square (RMS) to the final 3.68 nm RMS. Then another experiment is carried out to demonstrate the correcting capability of IBA for mid-to-high spatial frequency surface errors, and the final results indicate that the surface accuracy and surface quality can be simultaneously improved.

  12. How Developments in Psychology and Technology Challenge Validity Argumentation

    Science.gov (United States)

    Mislevy, Robert J.

    2016-01-01

    Validity is the sine qua non of properties of educational assessment. While a theory of validity and a practical framework for validation has emerged over the past decades, most of the discussion has addressed familiar forms of assessment and psychological framings. Advances in digital technologies and in cognitive and social psychology have…

  13. 77 FR 1708 - Cooperative Research and Development Agreement: Technology To Provide Wireless Precise Time...

    Science.gov (United States)

    2012-01-11

    ... Systems (GPS) as a means of providing precise time. The alternative under consideration is a wireless... authorized by the Federal Technology Transfer Act of 1986 (Pub. L. 99- 502, codified at 15 U.S.C. 3710(a)). A..., and document at least one alternative to Global Positioning Systems (GPS) as a means of providing...

  14. Real-time GPS seismology using a single receiver: method comparison, error analysis and precision validation

    Science.gov (United States)

    Li, Xingxing

    2014-05-01

    displacements is accompanied by a drift due to the potential uncompensated errors. Li et al. (2013) presented a temporal point positioning (TPP) method to quickly capture coseismic displacements with a single GPS receiver in real-time. The TPP approach can overcome the convergence problem of precise point positioning (PPP), and also avoids the integration and de-trending process of the variometric approach. The performance of TPP is demonstrated to be at few centimeters level of displacement accuracy for even twenty minutes interval with real-time precise orbit and clock products. In this study, we firstly present and compare the observation models and processing strategies of the current existing single-receiver methods for real-time GPS seismology. Furthermore, we propose several refinements to the variometric approach in order to eliminate the drift trend in the integrated coseismic displacements. The mathematical relationship between these methods is discussed in detail and their equivalence is also proved. The impact of error components such as satellite ephemeris, ionospheric delay, tropospheric delay, and geometry change on the retrieved displacements are carefully analyzed and investigated. Finally, the performance of these single-receiver approaches for real-time GPS seismology is validated using 1 Hz GPS data collected during the Tohoku-Oki earthquake (Mw 9.0, March 11, 2011) in Japan. It is shown that few centimeters accuracy of coseismic displacements is achievable. Keywords: High-rate GPS; real-time GPS seismology; a single receiver; PPP; variometric approach; temporal point positioning; error analysis; coseismic displacement; fault slip inversion;

  15. Building Technologies Program Multi-Year Program Plan Technology Validation and Market Introduction 2008

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2008-01-01

    Building Technologies Program Multi-Year Program Plan 2008 for technology validation and market introduction, including ENERGY STAR, building energy codes, technology transfer application centers, commercial lighting initiative, EnergySmart Schools, EnergySmar

  16. Using laser technological unit ALTI "Karavella" for precision components of IEP production

    Science.gov (United States)

    Labin, N. A.; Chursin, A. D.; Paramonov, V. S.; Klimenko, V. I.; Paramonova, G. M.; Kolokolov, I. S.; Vinogradov, K. Y.; Betina, L. L.; Bulychev, N. A.; Dyakov, Yu. A.; Zakharyan, R. A.; Kazaryan, M. A.; Koshelev, K. K.; Kosheleva, O. K.; Grigoryants, A. G.; Shiganov, I. N.; Krasovskii, V. I.; Sachkov, V. I.; Plyaka, P. S.; Feofanov, I. N.; Chen, C.

    2015-12-01

    The paper revealed the using of industrial production equipment ALTI "Karavella-1", "Karavella-1M", "Karavella-2" and "Karavella-2M" precision components of IEP production [1-4]. The basis for the ALTI using in the IEP have become the positive results of research and development of technologies of foil (0.01-0.2 mm) and thin sheets (0.3-1 mm) materials micromachining by pulsed radiation CVL [5, 6]. To assess the micromachining quality and precision the measuring optical microscope (UHL VMM200), projection microscope (Mitutoyo PV5100) and Carl Zeiss microscope were used.

  17. Precision and linearity targets for validation of an IFNγ ELISPOT, cytokine flow cytometry, and tetramer assay using CMV peptides

    Directory of Open Access Journals (Sweden)

    Lyerly Herbert K

    2008-03-01

    Full Text Available Abstract Background Single-cell assays of immune function are increasingly used to monitor T cell responses in immunotherapy clinical trials. Standardization and validation of such assays are therefore important to interpretation of the clinical trial data. Here we assess the levels of intra-assay, inter-assay, and inter-operator precision, as well as linearity, of CD8+ T cell IFNγ-based ELISPOT and cytokine flow cytometry (CFC, as well as tetramer assays. Results Precision was measured in cryopreserved PBMC with a low, medium, or high response level to a CMV pp65 peptide or peptide mixture. Intra-assay precision was assessed using 6 replicates per assay; inter-assay precision was assessed by performing 8 assays on different days; and inter-operator precision was assessed using 3 different operators working on the same day. Percent CV values ranged from 4% to 133% depending upon the assay and response level. Linearity was measured by diluting PBMC from a high responder into PBMC from a non-responder, and yielded R2 values from 0.85 to 0.99 depending upon the assay and antigen. Conclusion These data provide target values for precision and linearity of single-cell assays for those wishing to validate these assays in their own laboratories. They also allow for comparison of the precision and linearity of ELISPOT, CFC, and tetramer across a range of response levels. There was a trend toward tetramer assays showing the highest precision, followed closely by CFC, and then ELISPOT; while all three assays had similar linearity. These findings are contingent upon the use of optimized protocols for each assay.

  18. Impacts of the precision agricultural technologies in Iran: An analysis experts' perception & their determinants

    Directory of Open Access Journals (Sweden)

    Somayeh Tohidyan Far

    2018-03-01

    Full Text Available Nowadays agricultural methods developments that are productively, economically, environmentally and socially sustainable are required immediately. The concept of precision agriculture is becoming an attractive idea for managing natural resources and realizing modern sustainable agricultural development. The purpose of this study was to investigate factors influencing impacts of precision agriculture from the viewpoints of Boushehr Province experts. The research method was a cross sectional survey and multi-stage random sampling was used to collect data from 115 experts in Boushehr province. According to the results, experts found underground and surface waters conservation, rural areas development, increase of productivity and increasing income as the most important impacts of precision agricultural technologies. Experts’ attitudes indicate their positive view toward these kinds of impacts. Also behavioral attitude has the most effect on impacts.

  19. Precision Agriculture Technologies Positively Contributing to GHG Emissions Mitigation, Farm Productivity and Economics

    Directory of Open Access Journals (Sweden)

    Athanasios Balafoutis

    2017-07-01

    Full Text Available Agriculture is one of the economic sectors that affect climate change contributing to greenhouse gas emissions directly and indirectly. There is a trend of agricultural greenhouse gas emissions reduction, but any practice in this direction should not affect negatively farm productivity and economics because this would limit its implementation, due to the high global food and feed demand and the competitive environment in this sector. Precision agriculture practices using high-tech equipment has the ability to reduce agricultural inputs by site-specific applications, as it better target inputs to spatial and temporal needs of the fields, which can result in lower greenhouse gas emissions. Precision agriculture can also have a positive impact on farm productivity and economics, as it provides higher or equal yields with lower production cost than conventional practices. In this work, precision agriculture technologies that have the potential to mitigate greenhouse gas emissions are presented providing a short description of the technology and the impacts that have been reported in literature on greenhouse gases reduction and the associated impacts on farm productivity and economics. The technologies presented span all agricultural practices, including variable rate sowing/planting, fertilizing, spraying, weeding and irrigation.

  20. Precise orbit determination for quad-constellation satellites at Wuhan University: strategy, result validation, and comparison

    Science.gov (United States)

    Guo, Jing; Xu, Xiaolong; Zhao, Qile; Liu, Jingnan

    2016-02-01

    This contribution summarizes the strategy used by Wuhan University (WHU) to determine precise orbit and clock products for Multi-GNSS Experiment (MGEX) of the International GNSS Service (IGS). In particular, the satellite attitude, phase center corrections, solar radiation pressure model developed and used for BDS satellites are addressed. In addition, this contribution analyzes the orbit and clock quality of the quad-constellation products from MGEX Analysis Centers (ACs) for a common time period of 1 year (2014). With IGS final GPS and GLONASS products as the reference, Multi-GNSS products of WHU (indicated by WUM) show the best agreement among these products from all MGEX ACs in both accuracy and stability. 3D Day Boundary Discontinuities (DBDs) range from 8 to 27 cm for Galileo-IOV satellites among all ACs' products, whereas WUM ones are the largest (about 26.2 cm). Among three types of BDS satellites, MEOs show the smallest DBDs from 10 to 27 cm, whereas the DBDs for all ACs products are at decimeter to meter level for GEOs and one to three decimeter for IGSOs, respectively. As to the satellite laser ranging (SLR) validation for Galileo-IOV satellites, the accuracy evaluated by SLR residuals is at the one decimeter level with the well-known systematic bias of about -5 cm for all ACs. For BDS satellites, the accuracy could reach decimeter level, one decimeter level, and centimeter level for GEOs, IGSOs, and MEOs, respectively. However, there is a noticeable bias in GEO SLR residuals. In addition, systematic errors dependent on orbit angle related to mismodeled solar radiation pressure (SRP) are present for BDS GEOs and IGSOs. The results of Multi-GNSS combined kinematic PPP demonstrate that the best accuracy of position and fastest convergence speed have been achieved using WUM products, particularly in the Up direction. Furthermore, the accuracy of static BDS only PPP degrades when the BDS IGSO and MEO satellites switches to orbit-normal orientation

  1. Validating Advanced Supply-Chain Technology (VAST)

    Science.gov (United States)

    2004-06-01

    Use philosophy that is so important in today’s procurement environment. Electronic Data Interchange (EDI) and eCommerce is proving to be a major...the STEPwise methodology are particularly encouraging. These new EDI and eCommerce technologies are becoming more important with the customers who...critical assumption is based upon the 55 fact that eCommerce is growing throughout the commercial and military sector and those who are not

  2. Validating a Technology Enhanced Student-Centered Learning Model

    Science.gov (United States)

    Kang, Myunghee; Hahn, Jungsun; Chung, Warren

    2015-01-01

    The Technology Enhanced Student Centered Learning (TESCL) Model in this study presents the core factors that ensure the quality of learning in a technology-supported environment. Although the model was conceptually constructed using a student-centered learning framework and drawing upon previous studies, it should be validated through real-world…

  3. Advanced Energy Validated Photovoltaic Inverter Technology at NREL | Energy

    Science.gov (United States)

    Inverter Technology at NREL Advanced Energy Industries-NREL's first partner at the Energy Systems Integration Facility (ESIF)-validated its advanced photovoltaic (PV) inverter technology using the ESIF's computer screen in a laboratory, with power inverter hardware in the background Photo by Dennis Schroeder

  4. Precision manufacturing

    CERN Document Server

    Dornfeld, David

    2008-01-01

    Today there is a high demand for high-precision products. The manufacturing processes are now highly sophisticated and derive from a specialized genre called precision engineering. Precision Manufacturing provides an introduction to precision engineering and manufacturing with an emphasis on the design and performance of precision machines and machine tools, metrology, tooling elements, machine structures, sources of error, precision machining processes and precision process planning. As well as discussing the critical role precision machine design for manufacturing has had in technological developments over the last few hundred years. In addition, the influence of sustainable manufacturing requirements in precision processes is introduced. Drawing upon years of practical experience and using numerous examples and illustrative applications, David Dornfeld and Dae-Eun Lee cover precision manufacturing as it applies to: The importance of measurement and metrology in the context of Precision Manufacturing. Th...

  5. Research of precise pulse plasma arc powder welding technology of thin-walled inner hole parts

    Institute of Scientific and Technical Information of China (English)

    Li Zhanming; Du Xiaokun; Sun Xiaofeng; Song Wei

    2017-01-01

    The inner hole parts played an oriented or supporting role in engineering machinery and equipment,which are prone to appear surface damages such as wear,strain and corrosion.The precise pulse plasma arc powder welding method is used for surface damage repairing of inner hole parts in this paper.The working principle and process of the technology are illustrated,and the microstructure and property of repairing layer by precise pulse plasma powder welding and CO2 gas shielded welding are tested and observed by microscope,micro hardness tester and X-ray residual stress tester etc.Results showed that the substrate deformation of thin-walled inner hole parts samples by precise pulse plasma powder welding is relatively small.The repair layer and substrate is metallurgical bonding,the transition zones (including fusion zone and heat affected zone) are relatively narrow and the welding quality is good.h showed that the thin-walled inner hole parts can be repaired by this technology and equipment.

  6. Evaluation of Different Estimation Methods for Accuracy and Precision in Biological Assay Validation.

    Science.gov (United States)

    Yu, Binbing; Yang, Harry

    2017-01-01

    Biological assays ( bioassays ) are procedures to estimate the potency of a substance by studying its effects on living organisms, tissues, and cells. Bioassays are essential tools for gaining insight into biologic systems and processes including, for example, the development of new drugs and monitoring environmental pollutants. Two of the most important parameters of bioassay performance are relative accuracy (bias) and precision. Although general strategies and formulas are provided in USP, a comprehensive understanding of the definitions of bias and precision remain elusive. Additionally, whether there is a beneficial use of data transformation in estimating intermediate precision remains unclear. Finally, there are various statistical estimation methods available that often pose a dilemma for the analyst who must choose the most appropriate method. To address these issues, we provide both a rigorous definition of bias and precision as well as three alternative methods for calculating relative standard deviation (RSD). All methods perform similarly when the RSD ≤10%. However, the USP estimates result in larger bias and root-mean-square error (RMSE) compared to the three proposed methods when the actual variation was large. Therefore, the USP method should not be used for routine analysis. For data with moderate skewness and deviation from normality, the estimates based on the original scale perform well. The original scale method is preferred, and the method based on log-transformation may be used for noticeably skewed data. LAY ABSTRACT: Biological assays, or bioassays, are essential in the development and manufacture of biopharmaceutical products for potency testing and quality monitoring. Two important parameters of assay performance are relative accuracy (bias) and precision. The definitions of bias and precision in USP 〈1033〉 are elusive and confusing. Another complicating issue is whether log-transformation should be used for calculating the

  7. Sensing Technologies for Precision Phenotyping in Vegetable Crops: Current Status and Future Challenges

    Directory of Open Access Journals (Sweden)

    Pasquale Tripodi

    2018-04-01

    Full Text Available Increasing the ability to investigate plant functions and structure through non-invasive methods with high accuracy has become a major target in plant breeding and precision agriculture. Emerging approaches in plant phenotyping play a key role in unraveling quantitative traits responsible for growth, production, quality, and resistance to various stresses. Beyond fully automatic phenotyping systems, several promising technologies can help accurately characterize a wide range of plant traits at affordable costs and with high-throughput. In this review, we revisit the principles of proximal and remote sensing, describing the application of non-invasive devices for precision phenotyping applied to the protected horticulture. Potentiality and constraints of big data management and integration with “omics” disciplines will also be discussed.

  8. Understanding Student Teachers' Behavioural Intention to Use Technology: Technology Acceptance Model (TAM) Validation and Testing

    Science.gov (United States)

    Wong, Kung-Teck; Osman, Rosma bt; Goh, Pauline Swee Choo; Rahmat, Mohd Khairezan

    2013-01-01

    This study sets out to validate and test the Technology Acceptance Model (TAM) in the context of Malaysian student teachers' integration of their technology in teaching and learning. To establish factorial validity, data collected from 302 respondents were tested against the TAM using confirmatory factor analysis (CFA), and structural equation…

  9. Application of Multimodality Imaging Fusion Technology in Diagnosis and Treatment of Malignant Tumors under the Precision Medicine Plan.

    Science.gov (United States)

    Wang, Shun-Yi; Chen, Xian-Xia; Li, Yi; Zhang, Yu-Ying

    2016-12-20

    The arrival of precision medicine plan brings new opportunities and challenges for patients undergoing precision diagnosis and treatment of malignant tumors. With the development of medical imaging, information on different modality imaging can be integrated and comprehensively analyzed by imaging fusion system. This review aimed to update the application of multimodality imaging fusion technology in the precise diagnosis and treatment of malignant tumors under the precision medicine plan. We introduced several multimodality imaging fusion technologies and their application to the diagnosis and treatment of malignant tumors in clinical practice. The data cited in this review were obtained mainly from the PubMed database from 1996 to 2016, using the keywords of "precision medicine", "fusion imaging", "multimodality", and "tumor diagnosis and treatment". Original articles, clinical practice, reviews, and other relevant literatures published in English were reviewed. Papers focusing on precision medicine, fusion imaging, multimodality, and tumor diagnosis and treatment were selected. Duplicated papers were excluded. Multimodality imaging fusion technology plays an important role in tumor diagnosis and treatment under the precision medicine plan, such as accurate location, qualitative diagnosis, tumor staging, treatment plan design, and real-time intraoperative monitoring. Multimodality imaging fusion systems could provide more imaging information of tumors from different dimensions and angles, thereby offing strong technical support for the implementation of precision oncology. Under the precision medicine plan, personalized treatment of tumors is a distinct possibility. We believe that multimodality imaging fusion technology will find an increasingly wide application in clinical practice.

  10. Interior LED Lighting Technology. Navy Energy Technology Validation (Techval) Program

    Science.gov (United States)

    2015-09-01

    usually on most of the time. • Consider replacing existing CFL, high-intensity discharge (HID), or halogen lamp light fixtures/ lamps with LED fixtures... lamps . What is the Technology? An LED is a semiconductor-diode that emits light when power is applied. A driver is used, much as a ballast, to...available in integrated luminaires that can be used to replace existing luminaires. LEDs are also available as direct replacement lamps for many

  11. Precision Glass Molding: Validation of an FE Model for Thermo-Mechanical Simulation

    DEFF Research Database (Denmark)

    Sarhadi, Ali; Hattel, Jesper Henri; Hansen, Hans Nørgaard

    2014-01-01

    glass molding process including heating, pressing, and cooling stages. Temperature- dependent viscoelastic and structural relaxation behavior of the glass material are implemented through a FORTRAN material subroutine (UMAT) into the commercial FEM program ABAQUS, and the FE model is validated...

  12. Bias determination and precision validation of ozone profiles from MIPAS-Envisat retrieved with the IMK-IAA processor

    Directory of Open Access Journals (Sweden)

    T. Steck

    2007-07-01

    Full Text Available This paper characterizes vertical ozone profiles retrieved with the IMK-IAA (Institute for Meteorology and Climate Research, Karlsruhe – Instituto de Astrofisica de Andalucia science-oriented processor from high spectral resolution data (until March 2004 measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS aboard the environmental satellite Envisat. Bias determination and precision validation is performed on the basis of correlative measurements by ground-based lidars, Fourier transform infrared spectrometers, and microwave radiometers as well as balloon-borne ozonesondes, the balloon-borne version of MIPAS, and two satellite instruments (Halogen Occultation Experiment and Polar Ozone and Aerosol Measurement III. Percentage mean differences between MIPAS and the comparison instruments for stratospheric ozone are generally within ±10%. The precision in this altitude region is estimated at values between 5 and 10% which gives an accuracy of 15 to 20%. Below 18 km, the spread of the percentage mean differences is larger and the precision degrades to values of more than 20% depending on altitude and latitude. The main reason for the degraded precision at low altitudes is attributed to undetected thin clouds which affect MIPAS retrievals, and to the influence of uncertainties in the water vapor concentration.

  13. Validation of the Automated Method VIENA: An Accurate, Precise, and Robust Measure of Ventricular Enlargement

    NARCIS (Netherlands)

    Vrenken, H.; Vos, E.K.; van der Flier, W.M.; Sluimer, I.C.; Cover, K.S.; Knol, D.L.; Barkhof, F.

    2014-01-01

    Background: In many retrospective studies and large clinical trials, high-resolution, good-contrast 3DT1 images are unavailable, hampering detailed analysis of brain atrophy. Ventricular enlargement then provides a sensitive indirect measure of ongoing central brain atrophy. Validated automated

  14. Study on the high-precision laser welding technology of nuclear fuel elements processing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Sung; Yang, M. S.; Kim, W. K.; Lee, D. Y

    2001-01-01

    The proper welding method for appendage of bearing pads and spacers of PHWR nuclear fuel elements is considered important in respect to the soundness of weldments and the improvement of the performance of nuclear fuels during the operation in reactor. The probability of welding defects of the appendage parts is mostly apt to occur and it is connected directly with the safty and life prediction of the nuclear reactor in operation. Recently there has been studied all over the world to develope welding technology by laser in nuclear fuel processing, and the appendage of bearing pads and spacers of PHWR nuclear fuel elements. Therefore, the purpose of this study is to investigate the characteristics of the laser welded specimens and make some samples for the appendage of bearing pads of PHWR nuclear fuel elements. This study will be also provide the basic data for the fabrications of the appendage of bearing pads and spacers. Especially the laser welding is supposed to be used in the practical application such as precise materials manufacturing fields. In this respect this technology is not only a basic advanced technology with wide applications but also likely to be used for the development of directly applicable technologies for industries, with high potential benefits derived in the view point of economy and industry.

  15. Study on the high-precision laser welding technology of nuclear fuel elements processing

    International Nuclear Information System (INIS)

    Kim, Soo Sung; Yang, M. S.; Kim, W. K.; Lee, D. Y.

    2001-01-01

    The proper welding method for appendage of bearing pads and spacers of PHWR nuclear fuel elements is considered important in respect to the soundness of weldments and the improvement of the performance of nuclear fuels during the operation in reactor. The probability of welding defects of the appendage parts is mostly apt to occur and it is connected directly with the safty and life prediction of the nuclear reactor in operation. Recently there has been studied all over the world to develope welding technology by laser in nuclear fuel processing, and the appendage of bearing pads and spacers of PHWR nuclear fuel elements. Therefore, the purpose of this study is to investigate the characteristics of the laser welded specimens and make some samples for the appendage of bearing pads of PHWR nuclear fuel elements. This study will be also provide the basic data for the fabrications of the appendage of bearing pads and spacers. Especially the laser welding is supposed to be used in the practical application such as precise materials manufacturing fields. In this respect this technology is not only a basic advanced technology with wide applications but also likely to be used for the development of directly applicable technologies for industries, with high potential benefits derived in the view point of economy and industry

  16. High-precision analog circuit technology for power supply integrated circuits; Dengen IC yo koseido anarogu kairo gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nakamori, A.; Suzuki, T.; Mizoe, K. [Fuji Electric Corporate Research and Development,Ltd., Kanagawa (Japan)

    2000-08-10

    With the recent rapid spread of portable electronic appliances, specification requirements such as compact power supply and long operation with batteries have become severer. Power supply ICs (integrated circuits) are required to reduce power consumption in the circuit and perform high-precision control. To meet these requirements, Fuji Electric develops high-precision CMOS (complementary metal-oxide semiconductor) analog technology. This paper describes three analog circuit technologies of a voltage reference, an operational amplifier and a comparator as circuit components particularly important for the precision of power supply ICs. (author)

  17. Cheating Admission Self Report Scale: Evidence of Factorial Validity and Precision

    Directory of Open Access Journals (Sweden)

    Valdiney Veloso Gouveia

    2018-01-01

    Full Text Available This study aimed to adapt the Cheating Admission Self Report Scale (CASRSto the Brazilian context and collect evi-dence on factorial validity and internal consistency. 441 students participated (M=16 years, 54.6% females, randomly divided in two groups. All responded to CASRS and to demographic questions. The analysis of the main components demonstrated a bifactor structure, whose factors presented Cronbach’s alphas (α greater than .80 (G1. This structure was corroborated by means of confirmatory factor analysis (for example, CFI=.87 and RMSEA=.08. The scale was shown to be psychometrically adequate and there was evidence of factorial validity and internal consistency; the scale can be used to measure plagiarism in the academic context.

  18. Towards precision prevention: Technologies for identifying healthy individuals with high risk of disease.

    Science.gov (United States)

    Nagel, Zachary D; Engelward, Bevin P; Brenner, David J; Begley, Thomas J; Sobol, Robert W; Bielas, Jason H; Stambrook, Peter J; Wei, Qingyi; Hu, Jennifer J; Terry, Mary Beth; Dilworth, Caroline; McAllister, Kimberly A; Reinlib, Les; Worth, Leroy; Shaughnessy, Daniel T

    2017-08-01

    The rise of advanced technologies for characterizing human populations at the molecular level, from sequence to function, is shifting disease prevention paradigms toward personalized strategies. Because minimization of adverse outcomes is a key driver for treatment decisions for diseased populations, developing personalized therapy strategies represent an important dimension of both precision medicine and personalized prevention. In this commentary, we highlight recently developed enabling technologies in the field of DNA damage, DNA repair, and mutagenesis. We propose that omics approaches and functional assays can be integrated into population studies that fuse basic, translational and clinical research with commercial expertise in order to accelerate personalized prevention and treatment of cancer and other diseases linked to aberrant responses to DNA damage. This collaborative approach is generally applicable to efforts to develop data-driven, individualized prevention and treatment strategies for other diseases. We also recommend strategies for maximizing the use of biological samples for epidemiological studies, and for applying emerging technologies to clinical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Validation and Assessment of Multi-GNSS Real-Time Precise Point Positioning in Simulated Kinematic Mode Using IGS Real-Time Service

    Directory of Open Access Journals (Sweden)

    Liang Wang

    2018-02-01

    Full Text Available Precise Point Positioning (PPP is a popular technology for precise applications based on the Global Navigation Satellite System (GNSS. Multi-GNSS combined PPP has become a hot topic in recent years with the development of multiple GNSSs. Meanwhile, with the operation of the real-time service (RTS of the International GNSS Service (IGS agency that provides satellite orbit and clock corrections to broadcast ephemeris, it is possible to obtain the real-time precise products of satellite orbits and clocks and to conduct real-time PPP. In this contribution, the real-time multi-GNSS orbit and clock corrections of the CLK93 product are applied for real-time multi-GNSS PPP processing, and its orbit and clock qualities are investigated, first with a seven-day experiment by comparing them with the final multi-GNSS precise product ‘GBM’ from GFZ. Then, an experiment involving real-time PPP processing for three stations in the Multi-GNSS Experiment (MGEX network with a testing period of two weeks is conducted in order to evaluate the convergence performance of real-time PPP in a simulated kinematic mode. The experimental result shows that real-time PPP can achieve a convergence performance of less than 15 min for an accuracy level of 20 cm. Finally, the real-time data streams from 12 globally distributed IGS/MGEX stations for one month are used to assess and validate the positioning accuracy of real-time multi-GNSS PPP. The results show that the simulated kinematic positioning accuracy achieved by real-time PPP on different stations is about 3.0 to 4.0 cm for the horizontal direction and 5.0 to 7.0 cm for the three-dimensional (3D direction.

  20. The use of a cubesat to validate technological bricks in space

    Science.gov (United States)

    Rakotonimbahy, E.; Vives, S.; Dohlen, K.; Savini, G.; Iafolla, V.

    2017-11-01

    In the framework of the FP7 program FISICA (Far Infrared Space Interferometer Critical Assessment), we are developing a cubesat platform which will be used for the validation in space of two technological bricks relevant for FIRI. The first brick is a high-precision accelerometer which could be used in a future space mission as fundamental element for the dynamic control loop of the interferometer. The second brick is a miniaturized version of an imaging multi-aperture telescope. Ultimately, such an instrument could be composed of numerous space-born mirror segments flying in precise formation on baselines of hundreds or thousands of meters, providing high-resolution glimpses of distant worlds. We are proposing to build a very first space-born demonstrator of such an instrument which will fit into the limited resources of one cubesat. In this paper, we will describe the detailed design of the cubesat hosting the two payloads.

  1. Validating an infrared thermal switch as a novel access technology

    Directory of Open Access Journals (Sweden)

    Memarian Negar

    2010-08-01

    Full Text Available Abstract Background Recently, a novel single-switch access technology based on infrared thermography was proposed. The technology exploits the temperature differences between the inside and surrounding areas of the mouth as a switch trigger, thereby allowing voluntary switch activation upon mouth opening. However, for this technology to be clinically viable, it must be validated against a gold standard switch, such as a chin switch, that taps into the same voluntary motion. Methods In this study, we report an experiment designed to gauge the concurrent validity of the infrared thermal switch. Ten able-bodied adults participated in a series of 3 test sessions where they simultaneously used both an infrared thermal and conventional chin switch to perform multiple trials of a number identification task with visual, auditory and audiovisual stimuli. Participants also provided qualitative feedback about switch use. User performance with the two switches was quantified using an efficiency measure based on mutual information. Results User performance (p = 0.16 and response time (p = 0.25 with the infrared thermal switch were comparable to those of the gold standard. Users reported preference for the infrared thermal switch given its non-contact nature and robustness to changes in user posture. Conclusions Thermal infrared access technology appears to be a valid single switch alternative for individuals with disabilities who retain voluntary mouth opening and closing.

  2. Accounting for failures may improve precision: evidence supporting improved validity of self-reported condom use.

    Science.gov (United States)

    Crosby, Richard; Salazar, Laura F; DiClemente, Ralph J; Yarber, William L; Caliendo, Angela M; Staples-Horne, Michelle

    2005-08-01

    To determine whether a measure of unprotected vaginal sex that is adjusted for condom failures would produce improved accuracy in predicting biologically confirmed STDs (chlamydia and gonorrhea) among female teens. Self-reported measures were collected using audio-computer-assisted self-interviewing. DNA amplification for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae was conducted. The unadjusted measure of unprotected vaginal sex was not significantly associated with biologically confirmed prevalence of STDs (prevalence ratio [PR] = 1.51; 95% CI = 0.71-3.21; P = 0.28). Alternatively, the adjusted measure achieved significance (PR = 3.59; 95% CI = 1.13-11.38; P = 0.014). More than one quarter (25.6%) of teens using condoms inconsistently and/or incorrectly tested positive for an STD compared to 7.1% among those reporting the consistent and correct use of condoms. Findings demonstrate that studies of condom effectiveness should use an adjusted measure of condom use to achieve precision and rigor.

  3. Calibration and Validation of the Precision Nitrogen Management Tool for Artificially Drained Fields Under Maize

    Science.gov (United States)

    Marjerison, R.; Hutson, J.; Melkonian, J.; van Es, H.; Sela, S.

    2015-12-01

    Organic and inorganic fertilizer additions to agricultural fields can lead to soil nitrogen (N) levels in excess of those required for optimal crop growth. The primary loss pathways for this excess N are leaching and denitrification. Nitrate leaching from agricultural sources contributes to the formation of hypoxic zones in critical estuarine systems including the Chesapeake Bay and Gulf of Mexico. Denitrification can lead to the production of nitrous oxide (N2O), a potent greenhouse gas. Agricultural practices such as controlling the timing and location of fertilizer application can help reduce these losses. The Precision Nitrogen Management (PNM) model was developed to simulate water transport, nitrogen transformations and transport, and crop growth and nutrient uptake from agricultural fields. The PNM model allows for the prediction of N losses under a variety of crop and management scenarios. Recent improvements to the model include the option to simulate artificially drained fields. The model performs well in simulating drainage and nitrate leaching when compared to measured data from field studies in artificially drained soils in New York and Minnesota. A simulated N budget was compared to available data. The improved model will be used to assess different management options for reducing N losses in maize production under different climate projections for key maize production locations/systems in the U.S.

  4. Importance of Computer Model Validation in Pyroprocessing Technology Development

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y. E.; Li, Hui; Yim, M. S. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    In this research, we developed a plan for experimental validation of one of the computer models developed for ER process modeling, i. e., the ERAD code. Several candidate surrogate materials are selected for the experiment considering the chemical and physical properties. Molten salt-based pyroprocessing technology is being examined internationally as an alternative to treat spent nuclear fuel over aqueous technology. The central process in pyroprocessing is electrorefining(ER) which separates uranium from transuranic elements and fission products present in spent nuclear fuel. ER is a widely used process in the minerals industry to purify impure metals. Studies of ER by using actual spent nuclear fuel materials are problematic for both technical and political reasons. Therefore, the initial effort for ER process optimization is made by using computer models. A number of models have been developed for this purpose. But as validation of these models is incomplete and often times problematic, the simulation results from these models are inherently uncertain.

  5. On the validity of the effective field theory approach to SM precision tests

    Energy Technology Data Exchange (ETDEWEB)

    Contino, Roberto [EPFL, Lausanne (Switzerland). Inst. de Theorie des Phenomenes Physiques; CERN, Geneva (Switzerland). Theoretical Physics Dept.; Falkowski, Adam [Paris-11 Univ., 91 - Orsay (France). Lab. de Physique Theorique; Goertz, Florian; Riva, Francesco [CERN, Geneva (Switzerland). Theoretical Physics Dept.; Grojean, Christophe [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2016-09-15

    We discuss the conditions for an effective field theory (EFT) to give an adequate low-energy description of an underlying physics beyond the Standard Model (SM). Starting from the EFT where the SM is extended by dimension-6 operators, experimental data can be used without further assumptions to measure (or set limits on) the EFT parameters. The interpretation of these results requires instead a set of broad assumptions (e.g. power counting rules) on the UV dynamics. This allows one to establish, in a bottom-up approach, the validity range of the EFT description, and to assess the error associated with the truncation of the EFT series. We give a practical prescription on how experimental results could be reported, so that they admit a maximally broad range of theoretical interpretations. Namely, the experimental constraints on dimension-6 operators should be reported as functions of the kinematic variables that set the relevant energy scale of the studied process. This is especially important for hadron collider experiments where collisions probe a wide range of energy scales.

  6. Micro injection moulding process validation for high precision manufacture of thermoplastic elastomer micro suspension rings

    DEFF Research Database (Denmark)

    Calaon, M.; Tosello, G.; Elsborg Hansen, R.

    Micro injection moulding (μIM) is one of the most suitable micro manufacturing processes for flexible mass-production of multi-material functional micro components. The technology was employed in this research used to produce thermoplastic elastomer (TPE) micro suspension rings identified...... main μIM process parameters (melt temperature, injection speed, packing pressure) using the Design of Experiment statistical technique. Measurements results demonstrated the importance of calibrating mould´s master geometries to ensure correct part production and effective quality conformance...... on the frequency in order to improve the signal quality and assure acoustic reproduction fidelity. Production quality of the TPE rings drastically influence the product functionality. In the present study, a procedure for μIM TPE micro rings production optimization has been established. The procedure entail using...

  7. Development and Validation of Protein Microarray Technology for Simultaneous Inflammatory Mediator Detection in Human Sera

    Directory of Open Access Journals (Sweden)

    Senthooran Selvarajah

    2014-01-01

    Full Text Available Biomarkers, including cytokines, can help in the diagnosis, prognosis, and prediction of treatment response across a wide range of disease settings. Consequently, the recent emergence of protein microarray technology, which is able to quantify a range of inflammatory mediators in a large number of samples simultaneously, has become highly desirable. However, the cost of commercial systems remains somewhat prohibitive. Here we show the development, validation, and implementation of an in-house microarray platform which enables the simultaneous quantitative analysis of multiple protein biomarkers. The accuracy and precision of the in-house microarray system were investigated according to the Food and Drug Administration (FDA guidelines for pharmacokinetic assay validation. The assay fell within these limits for all but the very low-abundant cytokines, such as interleukin- (IL- 10. Additionally, there were no significant differences between cytokine detection using our microarray system and the “gold standard” ELISA format. Crucially, future biomarker detection need not be limited to the 16 cytokines shown here but could be expanded as required. In conclusion, we detail a bespoke protein microarray system, utilizing well-validated ELISA reagents, that allows accurate, precise, and reproducible multiplexed biomarker quantification, comparable with commercial ELISA, and allowing customization beyond that of similar commercial microarrays.

  8. Preparation and Integration of ALHAT Precision Landing Technology for Morpheus Flight Testing

    Science.gov (United States)

    Carson, John M., III; Robertson, Edward A.; Pierrottet, Diego F.; Roback, Vincent E.; Trawny, Nikolas; Devolites, Jennifer L.; Hart, Jeremy J.; Estes, Jay N.; Gaddis, Gregory S.

    2014-01-01

    The Autonomous precision Landing and Hazard Avoidance Technology (ALHAT) project has developed a suite of prototype sensors for enabling autonomous and safe precision land- ing of robotic or crewed vehicles on solid solar bodies under varying terrain lighting condi- tions. The sensors include a Lidar-based Hazard Detection System (HDS), a multipurpose Navigation Doppler Lidar (NDL), and a long-range Laser Altimeter (LAlt). Preparation for terrestrial ight testing of ALHAT onboard the Morpheus free- ying, rocket-propelled ight test vehicle has been in progress since 2012, with ight tests over a lunar-like ter- rain eld occurring in Spring 2014. Signi cant work e orts within both the ALHAT and Morpheus projects has been required in the preparation of the sensors, vehicle, and test facilities for interfacing, integrating and verifying overall system performance to ensure readiness for ight testing. The ALHAT sensors have undergone numerous stand-alone sensor tests, simulations, and calibrations, along with integrated-system tests in special- ized gantries, trucks, helicopters and xed-wing aircraft. A lunar-like terrain environment was constructed for ALHAT system testing during Morpheus ights, and vibration and thermal testing of the ALHAT sensors was performed based on Morpheus ights prior to ALHAT integration. High- delity simulations were implemented to gain insight into integrated ALHAT sensors and Morpheus GN&C system performance, and command and telemetry interfacing and functional testing was conducted once the ALHAT sensors and electronics were integrated onto Morpheus. This paper captures some of the details and lessons learned in the planning, preparation and integration of the individual ALHAT sen- sors, the vehicle, and the test environment that led up to the joint ight tests.

  9. Label-free screening of single biomolecules through resistive pulse sensing technology for precision medicine applications

    Science.gov (United States)

    Harrer, S.; Kim, S. C.; Schieber, C.; Kannam, S.; Gunn, N.; Moore, S.; Scott, D.; Bathgate, R.; Skafidas, S.; Wagner, J. M.

    2015-05-01

    Employing integrated nano- and microfluidic circuits for detecting and characterizing biological compounds through resistive pulse sensing technology is a vibrant area of research at the interface of biotechnology and nanotechnology. Resistive pulse sensing platforms can be customized to study virtually any particle of choice which can be threaded through a fluidic channel and enable label-free single-particle interrogation with the primary read-out signal being an electric current fingerprint. The ability to perform label-free molecular screening with single-molecule and even single binding site resolution makes resistive pulse sensing technology a powerful tool for analyzing the smallest units of biological systems and how they interact with each other on a molecular level. This task is at the core of experimental systems biology and in particular ‘omics research which in combination with next-generation DNA-sequencing and next-generation drug discovery and design forms the foundation of a novel disruptive medical paradigm commonly referred to as personalized medicine or precision medicine. DNA-sequencing has approached the 1000-Dollar-Genome milestone allowing for decoding a complete human genome with unmatched speed and at low cost. Increased sequencing efficiency yields massive amounts of genomic data. Analyzing this data in combination with medical and biometric health data eventually enables understanding the pathways from individual genes to physiological functions. Access to this information triggers fundamental questions for doctors and patients alike: what are the chances of an outbreak for a specific disease? Can individual risks be managed and if so how? Which drugs are available and how should they be applied? Could a new drug be tailored to an individual’s genetic predisposition fast and in an affordable way? In order to provide answers and real-life value to patients, the rapid evolvement of novel computing approaches for analyzing big data in

  10. Label-free screening of single biomolecules through resistive pulse sensing technology for precision medicine applications.

    Science.gov (United States)

    Harrer, S; Kim, S C; Schieber, C; Kannam, S; Gunn, N; Moore, S; Scott, D; Bathgate, R; Skafidas, S; Wagner, J M

    2015-05-08

    Employing integrated nano- and microfluidic circuits for detecting and characterizing biological compounds through resistive pulse sensing technology is a vibrant area of research at the interface of biotechnology and nanotechnology. Resistive pulse sensing platforms can be customized to study virtually any particle of choice which can be threaded through a fluidic channel and enable label-free single-particle interrogation with the primary read-out signal being an electric current fingerprint. The ability to perform label-free molecular screening with single-molecule and even single binding site resolution makes resistive pulse sensing technology a powerful tool for analyzing the smallest units of biological systems and how they interact with each other on a molecular level. This task is at the core of experimental systems biology and in particular 'omics research which in combination with next-generation DNA-sequencing and next-generation drug discovery and design forms the foundation of a novel disruptive medical paradigm commonly referred to as personalized medicine or precision medicine. DNA-sequencing has approached the 1000-Dollar-Genome milestone allowing for decoding a complete human genome with unmatched speed and at low cost. Increased sequencing efficiency yields massive amounts of genomic data. Analyzing this data in combination with medical and biometric health data eventually enables understanding the pathways from individual genes to physiological functions. Access to this information triggers fundamental questions for doctors and patients alike: what are the chances of an outbreak for a specific disease? Can individual risks be managed and if so how? Which drugs are available and how should they be applied? Could a new drug be tailored to an individual's genetic predisposition fast and in an affordable way? In order to provide answers and real-life value to patients, the rapid evolvement of novel computing approaches for analyzing big data in

  11. Seismic monitoring of small alpine rockfalls – validity, precision and limitations

    Directory of Open Access Journals (Sweden)

    M. Dietze

    2017-10-01

    processing: 2175 initially picked potential events reduced to 511 potential events after applying automatic rejection criteria. The 511 events needed to be inspected manually to reveal 19 short earthquakes and 37 potential rockfalls, including the 10 TLS-detected events. Rockfall volume does not show a relationship with released seismic energy or peak amplitude at this spatial scale due to the dominance of other, process-inherent factors, such as fall height, degree of fragmentation, and subsequent talus slope activity. The combination of TLS and environmental seismology provides, despite the significant amount of manual data processing, a detailed validation of seismic detection of small volume rockfalls, and revealed unprecedented temporal, spatial and geometric details about rockfalls in steep mountainous terrain.

  12. Vehicle modeling and duty cycle analysis to validate technology feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Castonguay, S. [National Centre for Advanced Transportation, Saint-Jerome, PQ (Canada)

    2010-07-01

    The National Centre for Advanced Transportation (CNTA) is a non-profit organization with a board consisting of representatives from the transportation industry, public service and public transit organizations, research and teaching institutions, and from municipal and economic development organizations. The objectives of the CNTA are to accelerate the introduction of electric and hybrid vehicles; act as a catalyst in projects; assist in increasing Canadian technology assets; initiate and support electric vehicle conversion projects; increase Canadian business for electric vehicles, hybrid vehicles, and plug-in electric vehicles; and provide a cost-effective solution and aggressive payback for road/off-road vehicles. This presentation provided an overview of the objectives and services of the CNTA. It discussed various road and off-road vehicles, duty cycle and technology of electric vehicles. Specific topics related to the technology were discussed, including configuration; controls and interface; efficiency maps; models and simulation; validation; and support. figs.

  13. Development and validation of educational technology for venous ulcer care.

    Science.gov (United States)

    Benevides, Jéssica Lima; Coutinho, Janaina Fonseca Victor; Pascoal, Liliane Chagas; Joventino, Emanuella Silva; Martins, Mariana Cavalcante; Gubert, Fabiane do Amaral; Alves, Allana Mirella

    2016-04-01

    To develop and validate an educational technology venous ulcers care. Methodological study conducted in five steps: Situational diagnosis; literature review; development of texts, illustrations and layout; apparent and content validity by the Content Validity Index, assessment of Flesch Readability Index; and pilot testing. The developed technology was a type of booklet entitled Booklet for Venous Ulcers Care, consisting of seven topics: Diet and food intake, walking and light exercise, resting with elevated leg, bandage care, compression therapy, family support, and keeping healthy habits. The apparent validity revealed minimal agreement of 85.7% in the clarity and comprehensibility. The total content validity index was 0.97, the Flesch Readability Index was 75%, corresponding to the reading "fairly easy". The pilot test showed that 100% of people with venous ulcers evaluated the text and the illustrations as understandable, as appropriate. The educational technology proved to be valid for the appearance and content with potential for use in clinical practice. Construir e validar uma tecnologia educativa para cuidados com úlcera venosa. Estudo metodológico realizado em cinco fases: diagnóstico situacional; revisão da literatura; desenvolvimento de textos, ilustrações e diagramação; validade de aparência e de conteúdo pelo Índice de Validade de Conteúdo, avaliação do Índice de Legibilidade de Flesch; e teste piloto. A tecnologia desenvolvida foi do tipo cartilha intitulada Cartilha para cuidados com úlcera venosa, constituída de sete tópicos: Alimentação, Caminhadas e exercícios leves, Repouso com a perna elevada, Cuidados com o curativo, Terapia compressiva, Apoio familiar, e manter hábitos saudáveis. A validade aparente revelou concordância mínima de 85,7% na clareza e compreensibilidade. O Índice de Validade de Conteúdo total foi de 0,97, o Índice de legibilidade de Flesch foi de 75%, o que correspondeu à leitura "razoavelmente f

  14. Replacement Technologies for Precision Cleaning of Aerospace Hardware for Propellant Service

    Science.gov (United States)

    Beeson, Harold; Kirsch, Mike; Hornung, Steven; Biesinger, Paul

    1997-01-01

    The NASA White Sands Test Facility (WSTF) is developing cleaning and verification processes to replace currently used chlorofluorocarbon-l13- (CFC-113-) based processes. The processes being evaluated include both aqueous- and solvent-based techniques. Replacement technologies are being investigated for aerospace hardware and for gauges and instrumentation. This paper includes the findings of investigations of aqueous cleaning and verification of aerospace hardware using known contaminants, such as hydraulic fluid and commonly used oils. The results correlate nonvolatile residue with CFC 113. The studies also include enhancements to aqueous sampling for organic and particulate contamination. Although aqueous alternatives have been identified for several processes, a need still exists for nonaqueous solvent cleaning, such as the cleaning and cleanliness verification of gauges used for oxygen service. The cleaning effectiveness of tetrachloroethylene (PCE), trichloroethylene (TCE), ethanol, hydrochlorofluorocarbon 225 (HCFC 225), HCFC 141b, HFE 7100(R), and Vertrel MCA(R) was evaluated using aerospace gauges and precision instruments and then compared to the cleaning effectiveness of CFC 113. Solvents considered for use in oxygen systems were also tested for oxygen compatibility using high-pressure oxygen autogenous ignition and liquid oxygen mechanical impact testing.

  15. Codon-Precise, Synthetic, Antibody Fragment Libraries Built Using Automated Hexamer Codon Additions and Validated through Next Generation Sequencing

    Directory of Open Access Journals (Sweden)

    Laura Frigotto

    2015-05-01

    Full Text Available We have previously described ProxiMAX, a technology that enables the fabrication of precise, combinatorial gene libraries via codon-by-codon saturation mutagenesis. ProxiMAX was originally performed using manual, enzymatic transfer of codons via blunt-end ligation. Here we present Colibra™: an automated, proprietary version of ProxiMAX used specifically for antibody library generation, in which double-codon hexamers are transferred during the saturation cycling process. The reduction in process complexity, resulting library quality and an unprecedented saturation of up to 24 contiguous codons are described. Utility of the method is demonstrated via fabrication of complementarity determining regions (CDR in antibody fragment libraries and next generation sequencing (NGS analysis of their quality and diversity.

  16. Understanding Student Teachers’ Behavioural Intention to Use Technology: Technology Acceptance Model (TAM Validation and Testing

    Directory of Open Access Journals (Sweden)

    Kung-Teck, Wong

    2013-01-01

    Full Text Available This study sets out to validate and test the Technology Acceptance Model (TAM in the context of Malaysian student teachers’ integration of their technology in teaching and learning. To establish factorial validity, data collected from 302 respondents were tested against the TAM using confirmatory factor analysis (CFA, and structural equation modelling (SEM was used for model comparison and hypotheses testing. The goodness-of-fit test of the analysis shows partial support of the applicability of the TAM in a Malaysian context. Overall, the TAM accounted for 37.3% of the variance in intention to use technology among student teachers and of the five hypotheses formulated, four are supported. Perceived usefulness is a significant influence on attitude towards computer use and behavioural intention. Perceived ease of use significantly influences perceived usefulness, and finally, behavioural intention is found to be influenced by attitude towards computer use. The findings of this research contribute to the literature by validating the TAM in the Malaysian context and provide several prominent implications for the research and practice of technology integration development.

  17. High precision NC lathe feeding system rigid-flexible coupling model reduction technology

    Science.gov (United States)

    Xuan, He; Hua, Qingsong; Cheng, Lianjun; Zhang, Hongxin; Zhao, Qinghai; Mao, Xinkai

    2017-08-01

    This paper proposes the use of dynamic substructure method of reduction of order to achieve effective reduction of feed system for high precision NC lathe feeding system rigid-flexible coupling model, namely the use of ADAMS to establish the rigid flexible coupling simulation model of high precision NC lathe, and then the vibration simulation of the period by using the FD 3D damper is very effective for feed system of bolt connection reduction of multi degree of freedom model. The vibration simulation calculation is more accurate, more quickly.

  18. Technologies for micro- and precision machining applications: Presentation held at International Specialized Exhibition Metalloobrabotka, 23.-27.05.2016, Moscow

    OpenAIRE

    Kugler, Till; Blau, Peter; Edelmann, Jan; Eckert, Udo; Koriath, Hans-Joachim; Bogachev, Yuri P.; Sakharova, Olga P.

    2016-01-01

    The use of microstructures or functional surfaces in powertrain components or molds and dies has attained increasing significance. Also the relevance of micro parts for various applications is still growing worldwide. Technologies for micro and precision machining applications are also becoming increasingly important in batch production. Main applications are primarily in the micro-analysis, automotive, medical engineering and watch-making industries. Customers are increasingly demanding equi...

  19. Development of millimeter-wave accelerating structures using precision metal forming technology

    Energy Technology Data Exchange (ETDEWEB)

    None

    2003-06-03

    High gradients in radio-frequency (RF) driven accelerators require short wavelengths that have the concomitant requirements of small feature size and high tolerances, 1-2 {micro}m for millimeter wavelengths. Precision metal-forming stampling has the promise of meeting those tolerances with high production rates. This STI will evaluate that promise.

  20. Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine. Part 3: Technical Validation of Immunohistochemistry (IHC) Assays in Clinical IHC Laboratories.

    Science.gov (United States)

    Torlakovic, Emina E; Cheung, Carol C; D'Arrigo, Corrado; Dietel, Manfred; Francis, Glenn D; Gilks, C Blake; Hall, Jacqueline A; Hornick, Jason L; Ibrahim, Merdol; Marchetti, Antonio; Miller, Keith; van Krieken, J Han; Nielsen, Soren; Swanson, Paul E; Vyberg, Mogens; Zhou, Xiaoge; Taylor, Clive R

    2017-03-01

    Validation of immunohistochemistry (IHC) assays is a subject that is of great importance to clinical practice as well as basic research and clinical trials. When applied to clinical practice and focused on patient safety, validation of IHC assays creates objective evidence that IHC assays used for patient care are "fit-for-purpose." Validation of IHC assays needs to be properly informed by and modeled to assess the purpose of the IHC assay, which will further determine what sphere of validation is required, as well as the scope, type, and tier of technical validation. These concepts will be defined in this review, part 3 of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."

  1. Linear accelerator based stereotactic radiosurgery with micro multi-leaf collimator : technological advancement in precision radiotherapy

    International Nuclear Information System (INIS)

    Dayananda, S.; Kinhikar, R.A.; Saju, Sherley; Deshpande, D.D.; Jalali, R.; Sarin, R.; Shrivastava, S.K.; Dinshaw, K.A.

    2003-01-01

    Stereotactic Radiosurgery (SRS) is an advancement on precision radiotherapy, in which stereo tactically guided localized high dose is delivered to the lesion (target) in a single fraction, while sparing the surrounding normal tissue. Radiosurgery has been used to treat variety of benign and malignant lesions as well as functional disorders in brain such as arteriovenous malformation (AVM), acoustic neuroma, solitary primary brain tumor, single metastasis, pituitary adenoma etc

  2. Precise focusing and diagnosis technology for laser beams in ICF target chamber

    International Nuclear Information System (INIS)

    Zhu Qixiang

    1999-01-01

    The precise focusing and diagnosis experimental system for laser beams in ICF target chamber is introduced. The system is controlled by computer. In process of focusing a series data of displacement in axial direction and relative area of focus spots are acquired. According to the functional curvature the accurate position of focal plane is determined. The construction of the system is simple, the system is controlled conveniently and runs quickly

  3. Development and Validation of a Precise and Stability Indicating LC Method for the Determination of Benzalkonium Chloride in Pharmaceutical Formulation Using an Experimental Design

    Directory of Open Access Journals (Sweden)

    Harshal K. Trivedi

    2010-01-01

    Full Text Available A simple, precise, shorter runtime and stability indicating reverse-phase high performance liquid chromatographic method has been developed and validated for the quantification of benzalkonium chloride (BKC preservative in pharmaceutical formulation of sparfloxacin eye drop. The method was successfully applied for determination of benzalkonium chloride in various ophthalmic formulations like latanoprost, timolol, dexametasone, gatifloxacin, norfloxacin, combination of moxifloxacin and dexamethasone, combination of nepthazoline HCl, zinc sulphate and chlorpheniramine maleate, combination of tobaramycin and dexamethasone, combination of phenylephrine HCl, naphazoline HCl, menthol and camphor. The RP-LC separation was achieved on an Purospher Star RP-18e 75 mm × 4.0 mm, 3.0 μ in the isocratic mode using buffer: acetonitrile (35: 65, v/v, as the mobile phase at a flow rate of 1.8 mL/min. The methods were performed at 215 nm; in LC method, quantification was achieved with PDA detection over the concentration range of 50 to 150 μg/mL. The method is effective to separate four homologs with good resolution in presence of excipients, sparfloxacin and degradable compound due to sparfloxacin and BKC within five minutes. The method was validated and the results were compared statistically. They were found to be simple, accurate, precise and specific. The proposed method was validated in terms of specificity, precision, recovery, solution stability, linearity and range. All the validation parameters were within the acceptance range and concordant to ICH guidelines.

  4. A high performance, high precision, low cost rapid prototyping and manufacturing technology

    OpenAIRE

    Viacheslav R. Shulunov

    2014-01-01

    A novel roll powder sintering (RPS) technology is proposed for processing real plastic, ceramic, metal and other 3-D objects 1m³ (or more) in volume directly from a CAD model within several hours. The breakthrough advantages of the technology are compared to the dominant rapid prototyping and manufacturing (RP&M) processes that are currently on the market.

  5. Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.

    Science.gov (United States)

    Chang, David F; Mamalis, Nick; Werner, Liliana

    2016-02-01

    To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Human cadaver eyes and New Zealand white rabbits. Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy discharge to produce a perfectly round anterior capsulotomy instantaneously and simultaneously along all 360°. Capsulotomies are performed using a disposable handpiece with a soft collapsible tip and circular nitinol cutting element. Miyake-Apple imaging and scanning electron microscopy (SEM) of PPC were conducted in human cadaver eyes. Surgical, postoperative slit-lamp, and histopathologic assessments of PPC were performed in 20 live rabbits and were compared with manual continuous curvilinear capsulorrhexis (CCC) in the fellow eye. Anterior chamber (AC) thermocouple temperature measurements were evaluated in a subset of rabbit eyes. Capsulotomy edge circularity, SEM morphologic features and zonular movement with PPC in human cadaver eyes. Anterior chamber temperature during PPC and grading of ocular inflammation, corneal endothelial damage, anterior capsular opacification (ACO), and posterior capsular opacification (PCO). Miyake-Apple imaging showed minimal zonular stress, and thermocouple measurements demonstrated negligible AC temperature changes during PPC. Precision pulse capsulotomy produced round, complete capsulotomies in all 20 rabbit eyes, leading to successful in-the-bag intraocular lens (IOL) implantation. Slit-lamp examinations at 3 days and 1, 2, and 4 weeks after surgery showed no significant differences between PPC and CCC in corneal edema, AC inflammatory reaction, capsular fibrosis, ACO, and PCO. Postmortem studies showed no difference in the corneal endothelium between PPC and CCC eyes. All IOLs were well centered in PPC eyes, and histopathologic analysis showed no greater inflammatory

  6. Precision Membrane Optical Shell (PMOS) Technology for RF/Microwave to Lightweight LIDAR Apertures, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Membrane Optical Shell Technology (MOST) is an innovative combination of 1) very low areal density (40 to 200g/m2) optically smooth (<20 nm rms), metallic coated...

  7. Precision farming solution in Egypt using the wireless sensor network technology

    Directory of Open Access Journals (Sweden)

    Sherine M. Abd El-kader

    2013-11-01

    Full Text Available This paper gives an overview of the wireless sensor network, studies its application in precision farming, and its importance for improving the agriculture in Egypt. An example for using wireless sensor network in cultivating the potato crop in Egypt is given, and it is shown that the cost of the system with respect to the yearly benefit from exporting potato crop after recovering the loss from its export preventing (this loss is estimated to be 2 billion pounds which is the value of the potato export to Russia annually, after the expected consequence of increasing the yield size and quality, after the expected savings in the resources used in cultivation such as the fertilizer and irrigation water, and after recovering the monetary loss results from the harms caused by excessive use of pesticides, is acceptable, and it can be said that this cost can be recovered in one year. It is concluded that the APTEEN protocol is the most suitable routing strategy to precision farming and its network lifetime can reach 6.5 month which is a period more than the maximum value of the potato crop lifetime that estimated to be 120 day, but it is greater than the yearly cultivation period of potato in Egypt which reaches 6 month.

  8. Improving livestock for agriculture - technological progress from random transgenesis to precision genome editing heralds a new era.

    Science.gov (United States)

    Laible, Götz; Wei, Jingwei; Wagner, Stefan

    2015-01-01

    Humans have a long history in shaping the genetic makeup of livestock to optimize production and meet growing human demands for food and other animal products. Until recently, this has only been possible through traditional breeding and selection, which is a painstakingly slow process of accumulating incremental gains over a long period. The development of transgenic livestock technology offers a more direct approach with the possibility for making genetic improvements with greater impact and within a single generation. However, initially the technology was hampered by technical difficulties and limitations, which have now largely been overcome by progressive improvements over the past 30 years. Particularly, the advent of genome editing in combination with homologous recombination has added a new level of efficiency and precision that holds much promise for the genetic improvement of livestock using the increasing knowledge of the phenotypic impact of genetic sequence variants. So far not a single line of transgenic livestock has gained approval for commercialization. The step change to genome-edited livestock with precise sequence changes may accelerate the path to market, provided applications of this new technology for agriculture can deliver, in addition to economic incentives for producers, also compelling benefits for animals, consumers, and the environment. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

    Science.gov (United States)

    Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C

    2018-06-01

    An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as

  10. Development and Validation of Information Technology Mentor Teacher Attitude Scale: A Pilot Study

    Science.gov (United States)

    Saltan, Fatih

    2015-01-01

    The aim of this study development and validation of a teacher attitude scale toward Information Technology Mentor Teachers (ITMT). ITMTs give technological support to other teachers for integration of technology in their lessons. In the literature, many instruments have been developed to measure teachers' attitudes towards the technological tools…

  11. Supporting precision Agriculture by Technology Intergration on an Inter and Intra Enterprise level

    NARCIS (Netherlands)

    Kruize, J.W.; Wolfert, J.; Scholten, H.; Beulens, A.J.M.

    2011-01-01

    Dutch agri-food supply chain network actors can use technologies, (web) services and tools to increase sustainable production and chain transparency in agriculture. Adoption of these (web) services and tools in arable farming is still low. Therefore, the Dutch ministry of agriculture started a

  12. Supporting Precision Agriculture by Technology Integration on a Inter and Intra Enterprise Level

    NARCIS (Netherlands)

    Kruize, J.W.; Wolfert, J.; Scholten, H.; Beulens, A.J.M.

    2011-01-01

    Dutch agri-food supply chain network actors can use technologies, (web) services and tools to increase sustainable production and chain transparency in agriculture. Adoption of these (web) services and tools in arable farming is still low. Therefore, the Dutch ministry of agriculture started a

  13. FY07 LDRD Final Report Precision, Split Beam, Chirped-Pulse, Seed Laser Technology

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, J W; Messerly, M J; Phan, H H; Crane, J K; Beach, R J; Siders, C W; Barty, C J

    2009-11-12

    The goal of this LDRD ER was to develop a robust and reliable technology to seed high-energy laser systems with chirped pulses that can be amplified to kilo-Joule energies and recompressed to sub-picosecond pulse widths creating extremely high peak powers suitable for petawatt class physics experiments. This LDRD project focused on the development of optical fiber laser technologies compatible with the current long pulse National Ignition Facility (NIF) seed laser. New technologies developed under this project include, high stability mode-locked fiber lasers, fiber based techniques for reduction of compressed pulse pedestals and prepulses, new compact stretchers based on chirped fiber Bragg gratings (CFBGs), new techniques for manipulation of chirped pulses prior to amplification and new high-energy fiber amplifiers. This project was highly successful and met virtually all of its goals. The National Ignition Campaign has found the results of this work to be very helpful. The LDRD developed system is being employed in experiments to engineer the Advanced Radiographic Capability (ARC) front end and the fully engineered version of the ARC Front End will employ much of the technology and techniques developed here.

  14. The Validity and Precision of the Comparative Interrupted Time-Series Design: Three Within-Study Comparisons

    Science.gov (United States)

    St. Clair, Travis; Hallberg, Kelly; Cook, Thomas D.

    2016-01-01

    We explore the conditions under which short, comparative interrupted time-series (CITS) designs represent valid alternatives to randomized experiments in educational evaluations. To do so, we conduct three within-study comparisons, each of which uses a unique data set to test the validity of the CITS design by comparing its causal estimates to…

  15. Multi Scale Micro and Nano Metrology for Advanced Precision Moulding Technologies

    DEFF Research Database (Denmark)

    Quagliotti, Danilo

    dimensions of the novel micro and nano production. Nowadays, design methodologies and concurrent tolerance guidelines are not yet available for advanced micro manufacture. Moreover, there are no shared methodologies that deals with the uncertainty evaluation of feature of size in the sub-millimetre scale......The technological revolution that has deeply influenced the manufacturing industry over the past two decades opened up new possibilities for the realisation of advanced micro and nano systems but, at the same time, traditional techniques for quality assurance became not adequate any longer......, as the technology progressed. The gap between the needs of the manufacturing industry and the well-organized structure of the dimensional and geometrical metrology appeared, above all, related to the methodologies and, also, to the instrumentation used to deal with the incessant scaling down of the critical...

  16. Research on precision grinding technology of large scale and ultra thin optics

    Science.gov (United States)

    Zhou, Lian; Wei, Qiancai; Li, Jie; Chen, Xianhua; Zhang, Qinghua

    2018-03-01

    The flatness and parallelism error of large scale and ultra thin optics have an important influence on the subsequent polishing efficiency and accuracy. In order to realize the high precision grinding of those ductile elements, the low deformation vacuum chuck was designed first, which was used for clamping the optics with high supporting rigidity in the full aperture. Then the optics was planar grinded under vacuum adsorption. After machining, the vacuum system was turned off. The form error of optics was on-machine measured using displacement sensor after elastic restitution. The flatness would be convergenced with high accuracy by compensation machining, whose trajectories were integrated with the measurement result. For purpose of getting high parallelism, the optics was turned over and compensation grinded using the form error of vacuum chuck. Finally, the grinding experiment of large scale and ultra thin fused silica optics with aperture of 430mm×430mm×10mm was performed. The best P-V flatness of optics was below 3 μm, and parallelism was below 3 ″. This machining technique has applied in batch grinding of large scale and ultra thin optics.

  17. A Vision of Quantitative Imaging Technology for Validation of Advanced Flight Technologies

    Science.gov (United States)

    Horvath, Thomas J.; Kerns, Robert V.; Jones, Kenneth M.; Grinstead, Jay H.; Schwartz, Richard J.; Gibson, David M.; Taylor, Jeff C.; Tack, Steve; Dantowitz, Ronald F.

    2011-01-01

    Flight-testing is traditionally an expensive but critical element in the development and ultimate validation and certification of technologies destined for future operational capabilities. Measurements obtained in relevant flight environments also provide unique opportunities to observe flow phenomenon that are often beyond the capabilities of ground testing facilities and computational tools to simulate or duplicate. However, the challenges of minimizing vehicle weight and internal complexity as well as instrumentation bandwidth limitations often restrict the ability to make high-density, in-situ measurements with discrete sensors. Remote imaging offers a potential opportunity to noninvasively obtain such flight data in a complementary fashion. The NASA Hypersonic Thermodynamic Infrared Measurements Project has demonstrated such a capability to obtain calibrated thermal imagery on a hypersonic vehicle in flight. Through the application of existing and accessible technologies, the acreage surface temperature of the Shuttle lower surface was measured during reentry. Future hypersonic cruise vehicles, launcher configurations and reentry vehicles will, however, challenge current remote imaging capability. As NASA embarks on the design and deployment of a new Space Launch System architecture for access beyond earth orbit (and the commercial sector focused on low earth orbit), an opportunity exists to implement an imagery system and its supporting infrastructure that provides sufficient flexibility to incorporate changing technology to address the future needs of the flight test community. A long term vision is offered that supports the application of advanced multi-waveband sensing technology to aid in the development of future aerospace systems and critical technologies to enable highly responsive vehicle operations across the aerospace continuum, spanning launch, reusable space access and global reach. Motivations for development of an Agency level imagery

  18. Ella-V and technology usage technology usage in an english language and literacy acquisition validation randomized controlled trial study

    OpenAIRE

    Roisin P. Corcoran; Steven M. Ross; Beverly J. Irby; Fuhui Tong; Rafael Lara-Alecio; Cindy Guerrero

    2014-01-01

    This paper describes the use of technology to provide virtual professional development (VPD) for teachers and to conduct classroom observations in a study of English Language Learner (ELL) instruction in grades K–3. The technology applications were part of a cluster randomized control trial (RCT) design for a federally funded longitudinal validation study of a particular program, English Language and Literacy Acquisition-Validation, ELLA- V, to determine its degree of impact on English oral l...

  19. Development and application of high-precision laser welding technology for manufacturing Ti alloy frames of glasses

    International Nuclear Information System (INIS)

    Kim, S. S.; Yang, M. S.; Kim, W. K.; Lee, D. Y.; Kim, J. M.; Leem, B. C.; Shin, J. S.; Lee, D. H.

    1999-12-01

    The research and development efforts of the high precision laser welding technology for manufacturing titanium alloy frames of glasses. For this purpose, laser welding device with the high beam quality is designed and fabricated, which consists of a optical fiber transmission part, a welding monitoring part and a welding controller. The welding nozzle and holding fixtures for manufacturing titanium and shape memory alloy frames of glasses. Titanium and shape memory alloy frames of glasses to be developed were experimentally manufactured by utilizing the laser welding using the optical fiber of GI 400 μm. As a result, the seam welding with the bead width of 0.3 mm or less and the weld penetration of 0.3-0.4mm could be accomplished. The fundamental technology was established through design of welding jigs with a variety of configurations and adequate welding conditions. Also, for the purpose to enable the companies participating in this project to commercialize the developed technology acceleratedly, a training program for the engineers belonging to such companies was conducted along with the technology transfer through joint experiments with the engineers. (author)

  20. An optimisation technology for more precise determination of a source for modelling radioactive releases to the atmosphere

    International Nuclear Information System (INIS)

    Golubenkov, A.V.; Borodin, R.V.

    1993-01-01

    This paper deals with refining meteorological parameters and source term characteristics required for models of atmospheric dispersion and deposition of radioactivity in the area adjacent to facilities affected by a nuclear accident. The proposed methodology involves the minimisation of an objective function that is the sum of weighted norms of deviations between measured and model values. The measured values are spatially interpolated and the weights determined by the type of measurement and the precision of interpolation. Consideration is given to a technique of initial approximation based on calculating regression functions for the parameters to be refined using measured radioactivity. Coefficients for these functions are calculated by analysis of a multitude of simulated situations. Also discussed is a heuristic method, using multiple random perturbations on the data, for assessing the validity of the solution. Based on these calculations confidence intervals are determined for the refined model parameters. (author)

  1. Application of dynamic compaction technology for high performance and precision powder products

    International Nuclear Information System (INIS)

    Lee, Chang Kyu; Lee, Jung Gu; Lee, Min Ku; Uhm, Young Rang; Park, Jin Ju; Lee, Gyeong Ja; Hong, Soon Jik

    2011-06-01

    The automation technology of magnetic pulsed compaction (MPC) has been developed for mass production of high performance powder products by dynamic compaction method. The pulse power equipment in MPC system has been modified for improved lifetime and productivity, so the modified one can produce high-density compacts at a rate of 10 times/min with semipermanent lifetime. Using this modified pulse power equipment, two types of automated MPC apparatus were constructed, which are operated by mechanical and hydraulic driving systems, respectively. By repeated compaction operations at a rate of 5 times/min, durability and productivity of these automated apparatus have been proven to be suitable for mass production. In addition, the lifetime of mold and punch for MPC has been improved by optimizing design and material as well as employing new lubrication system. By applying such automated MPC apparatus, detailed mass production technologies have been developed for several powder products such as diamond drilling segments, ceramic targets for optical coating, silver coins for water disinfection and small powder products for automobile. The developed powder products showed improved performance as compared to commercial ones, so they will be mass-produced industrially before long

  2. High-precision pose measurement method in wind tunnels based on laser-aided vision technology

    Directory of Open Access Journals (Sweden)

    Liu Wei

    2015-08-01

    Full Text Available The measurement of position and attitude parameters for the isolated target from a high-speed aircraft is a great challenge in the field of wind tunnel simulation technology. In this paper, firstly, an image acquisition method for small high-speed targets with multi-dimensional movement in wind tunnel environment is proposed based on laser-aided vision technology. Combining with the trajectory simulation of the isolated model, the reasonably distributed laser stripes and self-luminous markers are utilized to capture clear images of the object. Then, after image processing, feature extraction, stereo correspondence and reconstruction, three-dimensional information of laser stripes and self-luminous markers are calculated. Besides, a pose solution method based on projected laser stripes and self-luminous markers is proposed. Finally, simulation experiments on measuring the position and attitude of high-speed rolling targets are conducted, as well as accuracy verification experiments. Experimental results indicate that the proposed method is feasible and efficient for measuring the pose parameters of rolling targets in wind tunnels.

  3. Validation of an Instrument to Measure Students' Motivation and Self-Regulation towards Technology Learning

    Science.gov (United States)

    Liou, Pey-Yan; Kuo, Pei-Jung

    2014-01-01

    Background: Few studies have examined students' attitudinal perceptions of technology. There is no appropriate instrument to measure senior high school students' motivation and self-regulation toward technology learning among the current existing instruments in the field of technology education. Purpose: The present study is to validate an…

  4. Development and Validation of a Precise Method for Determination of Benzalkonium Chloride (BKC Preservative, in Pharmaceutical Formulation of Latanoprost Eye Drops

    Directory of Open Access Journals (Sweden)

    J. Mehta

    2010-01-01

    Full Text Available A simple and precise reversed phase high performance liquid chromatographic method has been developed and validated for the quantification of benzalkonium chloride (BKC preservative in pharmaceutical formulation of latanoprost eye drops. The analyte was chromatographed on a Waters Spherisorb CN, (4.6×250 mm column packed with particles of 5 μm. The mobile phase, optimized through an experimental design, was a 40:60 (v/v mixture of potassium dihydrogen orthophosphate buffer (pH 5.5 and acetonitrile, pumped at a flow rate of 1.0 mL/min at maintaining column temperature at 30 °C. Maximum UV detection was achieved at 210 nm. The method was validated in terms of linearity, repeatability, intermediate precision and method accuracy. The method was shown to be robust, resisting to small deliberate changes in pH, flow rate and composition (organic ratio of the mobile phase. The method was successfully applied for the determination of BKC in a pharmaceutical formulation of latanoprost ophthalmic solution without any interference from common excipients and drug substance. All the validation parameters were within the acceptance range, concordant to ICH guidelines.

  5. Semantic technologies improving the recall and precision of the Mercury metadata search engine

    Science.gov (United States)

    Pouchard, L. C.; Cook, R. B.; Green, J.; Palanisamy, G.; Noy, N.

    2011-12-01

    using the BioPortal REST API by passing a search parameter to BioPortal that may return domain context, parameter attribute, or entity annotations depending on the entity's associated ontological relationships. As Mercury's facetted search is popular with users, the results are displayed as facets. Unlike a facetted search however, the ontology-based solution implements both restrictions (improving precision) and expansions (improving recall) on the results of the initial search. For instance, "carbon" acquires a scientific context and additional key terms or phrases for discovering domain-specific datasets. A limitation of our solution is that the user must perform an additional step. Another limitation is that the quality of the newly discovered metadata is contingent upon the quality of the ontologies we use. Our solution leverages Mercury's federated capabilities to collect records from heterogeneous domains, and BioPortal's storage, curation and access capabilities for ontology entities. With minimal additional development, our approach builds on two mature systems for finding relevant datasets for interdisciplinary inquiries. We thus indicate a path forward for linking environmental, ecological and biological sciences. References: [1] Devarakonda, R., Palanisamy, G., Wilson, B. E., & Green, J. M. (2010). Mercury: reusable metadata management, data discovery and access system. Earth Science Informatics, 3(1-2), 87-94.

  6. Cellular Reprogramming, Genome Editing, and Alternative CRISPR Cas9 Technologies for Precise Gene Therapy of Duchenne Muscular Dystrophy

    Science.gov (United States)

    Xu, Huaigeng

    2017-01-01

    In the past decade, the development of two innovative technologies, namely, induced pluripotent stem cells (iPSCs) and the CRISPR Cas9 system, has enabled researchers to model diseases derived from patient cells and precisely edit DNA sequences of interest, respectively. In particular, Duchenne muscular dystrophy (DMD) has been an exemplary monogenic disease model for combining these technologies to demonstrate that genome editing can correct genetic mutations in DMD patient-derived iPSCs. DMD is an X-linked genetic disorder caused by mutations that disrupt the open reading frame of the dystrophin gene, which plays a critical role in stabilizing muscle cells during contraction and relaxation. The CRISPR Cas9 system has been shown to be capable of targeting the dystrophin gene and rescuing its expression in in vitro patient-derived iPSCs and in vivo DMD mouse models. In this review, we highlight recent advances made using the CRISPR Cas9 system to correct genetic mutations and discuss how emerging CRISPR technologies and iPSCs in a combined platform can play a role in bringing a therapy for DMD closer to the clinic. PMID:28607562

  7. Cellular Reprogramming, Genome Editing, and Alternative CRISPR Cas9 Technologies for Precise Gene Therapy of Duchenne Muscular Dystrophy

    Directory of Open Access Journals (Sweden)

    Peter Gee

    2017-01-01

    Full Text Available In the past decade, the development of two innovative technologies, namely, induced pluripotent stem cells (iPSCs and the CRISPR Cas9 system, has enabled researchers to model diseases derived from patient cells and precisely edit DNA sequences of interest, respectively. In particular, Duchenne muscular dystrophy (DMD has been an exemplary monogenic disease model for combining these technologies to demonstrate that genome editing can correct genetic mutations in DMD patient-derived iPSCs. DMD is an X-linked genetic disorder caused by mutations that disrupt the open reading frame of the dystrophin gene, which plays a critical role in stabilizing muscle cells during contraction and relaxation. The CRISPR Cas9 system has been shown to be capable of targeting the dystrophin gene and rescuing its expression in in vitro patient-derived iPSCs and in vivo DMD mouse models. In this review, we highlight recent advances made using the CRISPR Cas9 system to correct genetic mutations and discuss how emerging CRISPR technologies and iPSCs in a combined platform can play a role in bringing a therapy for DMD closer to the clinic.

  8. Vacuum decay container/closure integrity testing technology. Part 1. ASTM F2338-09 precision and bias studies.

    Science.gov (United States)

    Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Godorov, Phillip; Guazzo, Dana Morton

    2009-01-01

    ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method is applicable for leak-testing rigid and semi-rigid non-lidded trays; trays or cups sealed with porous barrier lidding materials; rigid, nonporous packages; and flexible, nonporous packages. Part 1 of this series describes the precision and bias studies performed in 2008 to expand this method's scope to include rigid, nonporous packages completely or partially filled with liquid. Round robin tests using three VeriPac 325/LV vacuum decay leak testers (Packaging Technologies & Inspection, LLC, Tuckahoe, NY) were performed at three test sites. Test packages were 1-mL glass syringes. Positive controls had laser-drilled holes in the barrel ranging from about 5 to 15 microm in nominal diameter. Two different leak tests methods were performed at each site: a "gas leak test" performed at 250 mbar (absolute) and a "liquid leak test" performed at about 1 mbar (absolute). The gas leak test was used to test empty, air-filled syringes. All defects with holes > or = 5.0 microm and all no-defect controls were correctly identified. The only false negative result was attributed to a single syringe with a ASTM F2338-09 test method and the precision and bias study report are available by contacting ASTM International in West Conshohocken, PA, USA (www.astm.org).

  9. Examining the Internal Validity and Statistical Precision of the Comparative Interrupted Time Series Design by Comparison with a Randomized Experiment

    Science.gov (United States)

    St.Clair, Travis; Cook, Thomas D.; Hallberg, Kelly

    2014-01-01

    Although evaluators often use an interrupted time series (ITS) design to test hypotheses about program effects, there are few empirical tests of the design's validity. We take a randomized experiment on an educational topic and compare its effects to those from a comparative ITS (CITS) design that uses the same treatment group as the experiment…

  10. Precise turnaround time measurement of laboratory processes using radiofrequency identification technology.

    Science.gov (United States)

    Mayer, Horst; Brümmer, Jens; Brinkmann, Thomas

    2011-01-01

    To implement Lean Six Sigma in our central laboratory we conducted a project to measure single pre-analytical steps influencing turnaround time (TAT) of emergency department (ED) serum samples. The traditional approach of extracting data from the Laboratory Information System (LIS) for a retrospective calculation of a mean TAT is not suitable. Therefore, we used radiofrequency identification (RFID) chips for real time tracking of individual samples at any pre-analytical step. 1,200 serum tubes were labelled with RFID chips and were provided to the emergency department. 3 RFID receivers were installed in the laboratory: at the outlet of the pneumatic tube system, at the centrifuge, and in the analyser area. In addition, time stamps of sample entry at the automated sample distributor and communication of results from the analyser were collected from LIS. 1,023 labelled serum tubes arrived at our laboratory. 899 RFID tags were used for TAT calculation. The following transfer times were determined (median 95th percentile in min:sec): pneumatic tube system --> centrifuge (01:25/04:48), centrifuge --> sample distributor (14:06/5:33), sample distributor --> analysis system zone (02:39/15:07), analysis system zone --> result communication (12:42/22:21). Total TAT was calculated at 33:19/57:40 min:sec. Manual processes around centrifugation were identified as a major part of TAT with 44%/60% (median/95th percentile). RFID is a robust, easy to use, and error-free technology and not susceptible to interferences in the laboratory environment. With this study design we were able to measure significant variations in a single manual sample transfer process. We showed that TAT is mainly influenced by manual steps around the centrifugation process and we concluded that centrifugation should be integrated in solutions for total laboratory automation.

  11. Health Information Technology Usability Evaluation Scale (Health-ITUES) for Usability Assessment of Mobile Health Technology: Validation Study.

    Science.gov (United States)

    Schnall, Rebecca; Cho, Hwayoung; Liu, Jianfang

    2018-01-05

    Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. ©Rebecca Schnall, Hwayoung Cho, Jianfang Liu. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 05.01.2018.

  12. Electrically Driven Thermal Management: Flight Validation, Experiment Development, Future Technologies

    Science.gov (United States)

    Didion, Jeffrey R.

    2018-01-01

    Electrically Driven Thermal Management is an active research and technology development initiative incorporating ISS technology flight demonstrations (STP-H5), development of Microgravity Science Glovebox (MSG) flight experiment, and laboratory-based investigations of electrically based thermal management techniques. The program targets integrated thermal management for future generations of RF electronics and power electronic devices. This presentation reviews four program elements: i.) results from the Electrohydrodynamic (EHD) Long Term Flight Demonstration launched in February 2017 ii.) development of the Electrically Driven Liquid Film Boiling Experiment iii.) two University based research efforts iv.) development of Oscillating Heat Pipe evaluation at Goddard Space Flight Center.

  13. The Sandia MEMS Passive Shock Sensor : FY08 testing for functionality, model validation, and technology readiness.

    Energy Technology Data Exchange (ETDEWEB)

    Walraven, Jeremy Allen; Blecke, Jill; Baker, Michael Sean; Clemens, Rebecca C.; Mitchell, John Anthony; Brake, Matthew Robert; Epp, David S.; Wittwer, Jonathan W.

    2008-10-01

    This report summarizes the functional, model validation, and technology readiness testing of the Sandia MEMS Passive Shock Sensor in FY08. Functional testing of a large number of revision 4 parts showed robust and consistent performance. Model validation testing helped tune the models to match data well and identified several areas for future investigation related to high frequency sensitivity and thermal effects. Finally, technology readiness testing demonstrated the integrated elements of the sensor under realistic environments.

  14. Trimodal nanoelectrode array for precise deep brain stimulation: prospects of a new technology based on carbon nanofiber arrays.

    Science.gov (United States)

    Li, J; Andrews, R J

    2007-01-01

    Although deep brain stimulation (DBS) has recently been shown to be effective for neurological disorders such as Parkinson's disease, there are many limitations of the current technology: the large size of current microelectrodes (approximately 1 mm diameter); the lack of monitoring of local brain electrical activity and neurotransmitters (e.g. dopamine in Parkinson's disease); the open-loop nature of the stimulation (i.e. not guided by brain electrochemical activity). Reducing the size of the monitoring and stimulating electrodes by orders of magnitude (to the size of neural elements) allows remarkable improvements in both monitoring (spatial resolution, temporal resolution, and sensitivity) and stimulation. Carbon nanofiber nanoelectrode technology offers the possibility of trimodal arrays (monitoring electrical activity, monitoring neurotransmitter levels, precise stimulation). DBS can then be guided by changes in brain electrical activity and/or neurotransmitter levels (i.e. closed-loop DBS). Here, we describe the basic manufacture and electrical characteristics of a prototype nanoelectrode array for DBS, as well as preliminary studies with electroconductive polymers necessary to optimize DBS in vivo. An approach such as the nanoelectrode array described here may offer a generic electrical-neural interface for use in various neural prostheses.

  15. Validation of an analytical method for simultaneous high-precision measurements of greenhouse gas emissions from wastewater treatment plants using a gas chromatography-barrier discharge detector system.

    Science.gov (United States)

    Pascale, Raffaella; Caivano, Marianna; Buchicchio, Alessandro; Mancini, Ignazio M; Bianco, Giuliana; Caniani, Donatella

    2017-01-13

    Wastewater treatment plants (WWTPs) emit CO 2 and N 2 O, which may lead to climate change and global warming. Over the last few years, awareness of greenhouse gas (GHG) emissions from WWTPs has increased. Moreover, the development of valid, reliable, and high-throughput analytical methods for simultaneous gas analysis is an essential requirement for environmental applications. In the present study, an analytical method based on a gas chromatograph (GC) equipped with a barrier ionization discharge (BID) detector was developed for the first time. This new method simultaneously analyses CO 2 and N 2 O and has a precision, measured in terms of relative standard of variation RSD%, equal to or less than 6.6% and 5.1%, respectively. The method's detection limits are 5.3ppm v for CO 2 and 62.0ppb v for N 2 O. The method's selectivity, linearity, accuracy, repeatability, intermediate precision, limit of detection and limit of quantification were good at trace concentration levels. After validation, the method was applied to a real case of N 2 O and CO 2 emissions from a WWTP, confirming its suitability as a standard procedure for simultaneous GHG analysis in environmental samples containing CO 2 levels less than 12,000mg/L. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Helicopter Flight Test of 3-D Imaging Flash LIDAR Technology for Safe, Autonomous, and Precise Planetary Landing

    Science.gov (United States)

    Roback, Vincent; Bulyshev, Alexander; Amzajerdian, Farzin; Reisse, Robert

    2013-01-01

    Two flash lidars, integrated from a number of cutting-edge components from industry and NASA, are lab characterized and flight tested for determination of maximum operational range under the Autonomous Landing and Hazard Avoidance Technology (ALHAT) project (in its fourth development and field test cycle) which is seeking to develop a guidance, navigation, and control (GN&C) and sensing system based on lidar technology capable of enabling safe, precise crewed or robotic landings in challenging terrain on planetary bodies under any ambient lighting conditions. The flash lidars incorporate pioneering 3-D imaging cameras based on Indium-Gallium-Arsenide Avalanche Photo Diode (InGaAs APD) and novel micro-electronic technology for a 128 x 128 pixel array operating at 30 Hz, high pulse-energy 1.06 micrometer Nd:YAG lasers, and high performance transmitter and receiver fixed and zoom optics. The two flash lidars are characterized on the NASA-Langley Research Center (LaRC) Sensor Test Range, integrated with other portions of the ALHAT GN&C system from partner organizations into an instrument pod at NASA-JPL, integrated onto an Erickson Aircrane Helicopter at NASA-Dryden, and flight tested at the Edwards AFB Rogers dry lakebed over a field of human-made geometric hazards during the summer of 2010. Results show that the maximum operational range goal of 1 km is met and exceeded up to a value of 1.2 km. In addition, calibrated 3-D images of several hazards are acquired in real-time for later reconstruction into Digital Elevation Maps (DEM's).

  17. Fiscal 1994 technological survey report. Research study on polymer materials by precision polymerization; 1994 nendo seimitsu jugo kobunshi zairyo ni kansuru chosa kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    In the paradigm that propelled polymer chemistry, there are involved the establishment of polymer concept, engineering plastics, regulation of higher ordered structure, and precision polymerization. The first two produced the polymer chemistry era in the 20th century. The regulation of higher ordered structure and the precision polymerization are the fundamental technologies supporting the polymer chemistry of the 21st century. The precision polymerization is a technology for regulating the stereospecificity, sequential structure, and molecular weight of polymers by regulating atoms and molecules and is referred to the following important techniques to be concrete. In the precision addition polymerization, stereospecific regulation and purification of active site to give living polymers are required while, in the precision condensation polymerization, regulation of condensation probability process to be secondary Marcov chain is necessary, as is the establishment of non-defect condensation condition avoiding high temperature deterioration and the like. In the biomimetic precision polymerization, key issues are the method of incorporating molecular recognition control and sequential structure control by living organs into an industrial process. If the higher ordered structure can be regulated by the precision polymerization, it is possible to obtain numerous high performance/high functional materials such as superconductors. (NEDO)

  18. SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

    Energy Technology Data Exchange (ETDEWEB)

    Wood, R; Iacobucci, G; Khobragade, P; Ying, L; Snyder, K; Wack, D; Rudin, S; Ionita, C [University at Buffalo, Buffalo, NY (United States)

    2014-06-15

    Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

  19. SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

    International Nuclear Information System (INIS)

    Wood, R; Iacobucci, G; Khobragade, P; Ying, L; Snyder, K; Wack, D; Rudin, S; Ionita, C

    2014-01-01

    Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation

  20. VATE: VAlidation of high TEchnology based on large database analysis by learning machine

    NARCIS (Netherlands)

    Meldolesi, E; Van Soest, J; Alitto, A R; Autorino, R; Dinapoli, N; Dekker, A; Gambacorta, M A; Gatta, R; Tagliaferri, L; Damiani, A; Valentini, V

    2014-01-01

    The interaction between implementation of new technologies and different outcomes can allow a broad range of researches to be expanded. The purpose of this paper is to introduce the VAlidation of high TEchnology based on large database analysis by learning machine (VATE) project that aims to combine

  1. Validation Study on the MCC-based Technology

    International Nuclear Information System (INIS)

    Park, Sungkeun; Lee, Dowhan; Kang, Shincheul; Choi, Hyunwoo; Chai, Jangbom

    2006-01-01

    KEPRI and M and D Corporation has developed a methodology, called the NEST I (Non-intrusive Evaluation of Stem Thrust), for determining the stem thrust for a Motor Operated Valve (MOV) based on the motor torque and the stem displacement. The motor torque is determined using another method called NEET (Non-intrusive Evaluation of Electric Torque) which uses the voltage and current data from three phases to obtain the motor torque. The stem displacement is obtained from the voltage and current data along with the nameplate information of the motor, actuator and stem. The motor data (voltage, current and coil current) are measured using MOVIDS (Motor Operated Valve Intelligent Diagnostic System). The motor torque is determined using a NEET algorithm and the stem thrust is calculated using the NEST I method. The goal of this testing was to obtain data from operation of a MOV and to compare the actual measured thrust with the thrust calculated using the NEET / NEST I methods and therefore validate the NEET / NEST I methods

  2. Investigation of CMOS pixel sensor with 0.18 μm CMOS technology for high-precision tracking detector

    International Nuclear Information System (INIS)

    Zhang, L.; Wang, M.; Fu, M.; Zhang, Y.; Yan, W.

    2017-01-01

    The Circular Electron Positron Collider (CEPC) proposed by the Chinese high energy physics community is aiming to measure Higgs particles and their interactions precisely. The tracking detector including Silicon Inner Tracker (SIT) and Forward Tracking Disks (FTD) has driven stringent requirements on sensor technologies in term of spatial resolution, power consumption and readout speed. CMOS Pixel Sensor (CPS) is a promising candidate to approach these requirements. This paper presents the preliminary studies on the sensor optimization for tracking detector to achieve high collection efficiency while keeping necessary spatial resolution. Detailed studies have been performed on the charge collection using a 0.18 μm CMOS image sensor process. This process allows high resistivity epitaxial layer, leading to a significant improvement on the charge collection and therefore improving the radiation tolerance. Together with the simulation results, the first exploratory prototype has bee designed and fabricated. The prototype includes 9 different pixel arrays, which vary in terms of pixel pitch, diode size and geometry. The total area of the prototype amounts to 2 × 7.88 mm 2 .

  3. Laser technology to manage periodontal disease: a valid concept?

    Science.gov (United States)

    Low, Samuel B; Mott, Angie

    2014-06-01

    Present day dental lasers can create oral environments conducive for periodontal repair. With the bacterial etiology of periodontitis and the resulting host inflammatory reaction, clinicians continue to search for therapeutic modalities to assist in the non-surgical management of periodontal disease. Traditional chairside therapies consist of mechanical debridement with manual and/or ultrasonic instrumentation with the objective of removing calculus, biofilm, and endotoxin from tooth root surfaces. Decreasing the microbial stimuli and associated end products decreases the inflammatory reaction and allows the host an opportunity to regenerate tissue through wound healing. The purpose of this article is to examine whether dental lasers, which have been in use for the past 3 decades, may augment traditional non-surgical periodontal therapy. Review of research publications related to lasers and non-surgical periodontics with attention focused on systematic studies. Studies utilizing laser technology may demonstrate positive effects on 1) selectively decreasing the biofilm environment, 2) removing calculus deposits and neutralizing endotoxin, 3) removing sulcular epithelium to assist in reattachment and decreased pocket depth, and 4) biostimulation for enhanced wound healing. Comparisons of studies to determine the difference between lasers and their respective effects on the periodontium are difficult to assess due to a wide variation of laser protocols. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Validation of morphing wing methodologies on an unmanned aerial system and a wind tunnel technology demonstrator

    Science.gov (United States)

    Gabor, Oliviu Sugar

    To increase the aerodynamic efficiency of aircraft, in order to reduce the fuel consumption, a novel morphing wing concept has been developed. It consists in replacing a part of the wing upper and lower surfaces with a flexible skin whose shape can be modified using an actuation system placed inside the wing structure. Numerical studies in two and three dimensions were performed in order to determine the gains the morphing system achieves for the case of an Unmanned Aerial System and for a morphing technology demonstrator based on the wing tip of a transport aircraft. To obtain the optimal wing skin shapes in function of the flight condition, different global optimization algorithms were implemented, such as the Genetic Algorithm and the Artificial Bee Colony Algorithm. To reduce calculation times, a hybrid method was created by coupling the population-based algorithm with a fast, gradient-based local search method. Validations were performed with commercial state-of-the-art optimization tools and demonstrated the efficiency of the proposed methods. For accurately determining the aerodynamic characteristics of the morphing wing, two new methods were developed, a nonlinear lifting line method and a nonlinear vortex lattice method. Both use strip analysis of the span-wise wing section to account for the airfoil shape modifications induced by the flexible skin, and can provide accurate results for the wing drag coefficient. The methods do not require the generation of a complex mesh around the wing and are suitable for coupling with optimization algorithms due to the computational time several orders of magnitude smaller than traditional three-dimensional Computational Fluid Dynamics methods. Two-dimensional and three-dimensional optimizations of the Unmanned Aerial System wing equipped with the morphing skin were performed, with the objective of improving its performances for an extended range of flight conditions. The chordwise positions of the internal actuators

  5. Validation of an instrument to measure students' motivation and self-regulation towards technology learning

    Science.gov (United States)

    Liou, Pey-Yan; Kuo, Pei-Jung

    2014-05-01

    Background:Few studies have examined students' attitudinal perceptions of technology. There is no appropriate instrument to measure senior high school students' motivation and self-regulation toward technology learning among the current existing instruments in the field of technology education. Purpose:The present study is to validate an instrument for assessing senior high school students' motivation and self-regulation towards technology learning. Sample:A total of 1822 Taiwanese senior high school students (1020 males and 802 females) responded to the newly developed instrument. Design and method:The Motivation and Self-regulation towards Technology Learning (MSRTL) instrument was developed based on the previous instruments measuring students' motivation and self-regulation towards science learning. Exploratory and confirmatory factor analyses were utilized to investigate the structure of the items. Cronbach's alpha was applied for measuring the internal consistency of each scale. Furthermore, multivariate analysis of variance was used to examine gender differences. Results:Seven scales, including 'Technology learning self-efficacy,' 'Technology learning value,' 'Technology active learning strategies,' 'Technology learning environment stimulation,' 'Technology learning goal-orientation,' 'Technology learning self-regulation-triggering,' and 'Technology learning self-regulation-implementing' were confirmed for the MSRTL instrument. Moreover, the results also showed that male and female students did not present the same degree of preference in all of the scales. Conclusions:The MSRTL instrument composed of seven scales corresponding to 39 items was shown to be valid based on validity and reliability analyses. While male students tended to express more positive and active performance in the motivation scales, no gender differences were found in the self-regulation scales.

  6. High Technology Development and Creation of Experimental Industrial Area of High-Performance Precision Diamond Dress Tool Production for Engineering Needs and Import Substitution in Ukraine

    Directory of Open Access Journals (Sweden)

    N. Novikov

    2013-09-01

    Full Text Available Manufacturing design of high-precision diamond tool for special applications carried out at V. M Bakul Institute for Superhard Materials of NAS of Ukraine is described. Presented developments open up scientific and technological capabilities of special dress diamond tool production for mechanical engineering and substitution of imported tools at Ukrainian enterprises by home-produced.

  7. Validation of the Impact of Health Information Technology (I-HIT) Scale: an international collaborative.

    Science.gov (United States)

    Dykes, Patricia C; Hurley, Ann C; Brown, Suzanne; Carr, Robyn; Cashen, Margaret; Collins, Rita; Cook, Robyn; Currie, Leanne; Docherty, Charles; Ensio, Anneli; Foster, Joanne; Hardiker, Nicholas R; Honey, Michelle L L; Killalea, Rosaleen; Murphy, Judy; Saranto, Kaija; Sensmeier, Joyce; Weaver, Charlotte

    2009-01-01

    In 2005, the Healthcare Information Management Systems Society (HIMSS) Nursing Informatics Community developed a survey to measure the impact of health information technology (HIT), the I-HIT Scale, on the role of nurses and interdisciplinary communication in hospital settings. In 2007, nursing informatics colleagues from Australia, England, Finland, Ireland, New Zealand, Scotland and the United States formed a research collaborative to validate the I-HIT across countries. All teams have completed construct and face validation in their countries. Five out of six teams have initiated reliability testing by practicing nurses. This paper reports the international collaborative's validation of the I-HIT Scale completed to date.

  8. Ultra-Precision Manufacturing Technology for Miniature & Complex-Form Integrated Opto-Mechanical Structures for Sensors Payloads, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate ultra precision manufacturing of components for NASA payloads, specifically for electro-optical and infrared sensors that are used in...

  9. Precision Joining Center

    Science.gov (United States)

    Powell, J. W.; Westphal, D. A.

    1991-08-01

    A workshop to obtain input from industry on the establishment of the Precision Joining Center (PJC) was held on July 10-12, 1991. The PJC is a center for training Joining Technologists in advanced joining techniques and concepts in order to promote the competitiveness of U.S. industry. The center will be established as part of the DOE Defense Programs Technology Commercialization Initiative, and operated by EG&G Rocky Flats in cooperation with the American Welding Society and the Colorado School of Mines Center for Welding and Joining Research. The overall objectives of the workshop were to validate the need for a Joining Technologists to fill the gap between the welding operator and the welding engineer, and to assure that the PJC will train individuals to satisfy that need. The consensus of the workshop participants was that the Joining Technologist is a necessary position in industry, and is currently used, with some variation, by many companies. It was agreed that the PJC core curriculum, as presented, would produce a Joining Technologist of value to industries that use precision joining techniques. The advantage of the PJC would be to train the Joining Technologist much more quickly and more completely. The proposed emphasis of the PJC curriculum on equipment intensive and hands-on training was judged to be essential.

  10. Validation of the Domains of Creativity Scale for Nigerian Preservice Science, Technology, and Mathematics Teachers

    Science.gov (United States)

    Awofala, Adeneye O. A.; Fatade, Alfred O.

    2015-01-01

    Introduction: Investigation into the factor structure of Domains of Creativity Scale has been on for sometimes now. The purpose of this study was to test the validity of the Kaufman Domains of Creativity Scale on Nigerian preservice science, technology, and mathematics teachers. Method: Exploratory and confirmatory factor analyses were performed…

  11. Assistive technology for visually impaired women for use of the female condom: a validation study

    Directory of Open Access Journals (Sweden)

    Luana Duarte Wanderley Cavalcante

    2015-02-01

    Full Text Available OBJECTIVE To validate assistive technology for visually impaired women to learn how to use the female condom. METHOD a methodological development study conducted on a web page, with data collection between May and October 2012. Participants were 14 judges; seven judges in sexual and reproductive health (1st stage and seven in special education (2nd stage. RESULTS All items have reached the adopted parameter of 70% agreement. In Stage 1 new materials were added to represent the cervix, and instructions that must be heard twice were included in the 2nd stage. CONCLUSION The technology has been validated and is appropriate for its objectives, structure / presentation and relevance. It is an innovative, low cost and valid instrument for promoting health and one which may help women with visual disabilities to use the female condom.

  12. Ella-V and technology usage technology usage in an english language and literacy acquisition validation randomized controlled trial study

    Directory of Open Access Journals (Sweden)

    Roisin P. Corcoran

    2014-12-01

    Full Text Available This paper describes the use of technology to provide virtual professional development (VPD for teachers and to conduct classroom observations in a study of English Language Learner (ELL instruction in grades K–3. The technology applications were part of a cluster randomized control trial (RCT design for a federally funded longitudinal validation study of a particular program, English Language and Literacy Acquisition-Validation, ELLA- V, to determine its degree of impact on English oral language/literacy, reading, and science across 63 randomly assigned urban, suburban, and rural schools (first year of implementation. ELLA-V also examines the impact of bimonthly VPD for treatment teachers compared to comparison group teachers on pedagogical skills, measured by sound observation instruments, and on student achievement, measured by state/national English language/literacy/reading tests and a national science test. This study features extensive technology use via virtual observations, bimonthly VPD, and randomly assigned treatment and control schools with students served in English as second language (ESL instructional time. The study design and methodology are discussed relativeto the specialized uses of technology and issues involving the evaluation of technology’s contribution to the intervention of interest and of the efficient, cost-effective execution of the study.

  13. Development and Validation of a Precise, Single HPLC Method for the Determination of Tolperisone Impurities in API and Pharmaceutical Dosage Forms.

    Science.gov (United States)

    Raju, Thummala Veera Raghava; Seshadri, Raja Kumar; Arutla, Srinivas; Mohan, Tharlapu Satya Sankarsana Jagan; Rao, Ivaturi Mrutyunjaya; Nittala, Someswara Rao

    2013-01-01

    A novel, sensitive, stability-indicating HPLC method has been developed for the quantitative estimation of Tolperisone-related impurities in both bulk drugs and pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with a simple mobile phase combination delivered in a simple gradient programme, and quantitation was by ultraviolet detection at 254 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 1.0 ml/min. The buffer consisted of 0.01 M potassium dihydrogen phosphate with the pH adjusted to 8.0 by using diethylamine. In the developed HPLC method, the resolution between Tolperisone and its four potential impurities was found to be greater than 2.0. Regression analysis showed an R value (correlation coefficient) of greater than 0.999 for the Tolperisone impurities. This method was capable of detecting all four impurities of Tolperisone at a level of 0.19 μg/mL with respect to the test concentration of 1000 μg/mL for a 10 µl injection volume. The tablets were subjected to the stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation. Considerable degradation was found to occur in base hydrolysis, water hydrolysis, and oxidation. The stress samples were assayed against a qualified reference standard and the mass balance was found to be close to 100%. The established method was validated and found to be linear, accurate, precise, specific, robust, and rugged.

  14. Laser precision microfabrication

    CERN Document Server

    Sugioka, Koji; Pique, Alberto

    2010-01-01

    Miniaturization and high precision are rapidly becoming a requirement for many industrial processes and products. As a result, there is greater interest in the use of laser microfabrication technology to achieve these goals. This book composed of 16 chapters covers all the topics of laser precision processing from fundamental aspects to industrial applications to both inorganic and biological materials. It reviews the sate of the art of research and technological development in the area of laser processing.

  15. A Process Analytical Technology (PAT) approach to control a new API manufacturing process: development, validation and implementation.

    Science.gov (United States)

    Schaefer, Cédric; Clicq, David; Lecomte, Clémence; Merschaert, Alain; Norrant, Edith; Fotiadu, Frédéric

    2014-03-01

    Pharmaceutical companies are progressively adopting and introducing Process Analytical Technology (PAT) and Quality-by-Design (QbD) concepts promoted by the regulatory agencies, aiming the building of the quality directly into the product by combining thorough scientific understanding and quality risk management. An analytical method based on near infrared (NIR) spectroscopy was developed as a PAT tool to control on-line an API (active pharmaceutical ingredient) manufacturing crystallization step during which the API and residual solvent contents need to be precisely determined to reach the predefined seeding point. An original methodology based on the QbD principles was designed to conduct the development and validation of the NIR method and to ensure that it is fitted for its intended use. On this basis, Partial least squares (PLS) models were developed and optimized using chemometrics methods. The method was fully validated according to the ICH Q2(R1) guideline and using the accuracy profile approach. The dosing ranges were evaluated to 9.0-12.0% w/w for the API and 0.18-1.50% w/w for the residual methanol. As by nature the variability of the sampling method and the reference method are included in the variability obtained for the NIR method during the validation phase, a real-time process monitoring exercise was performed to prove its fit for purpose. The implementation of this in-process control (IPC) method on the industrial plant from the launch of the new API synthesis process will enable automatic control of the final crystallization step in order to ensure a predefined quality level of the API. In addition, several valuable benefits are expected including reduction of the process time, suppression of a rather difficult sampling and tedious off-line analyses. © 2013 Published by Elsevier B.V.

  16. From technological advances to biological understanding: The main steps toward high-precision RT in breast cancer.

    Science.gov (United States)

    Leonardi, Maria Cristina; Ricotti, Rosalinda; Dicuonzo, Samantha; Cattani, Federica; Morra, Anna; Dell'Acqua, Veronica; Orecchia, Roberto; Jereczek-Fossa, Barbara Alicja

    2016-10-01

    Radiotherapy improves local control in breast cancer (BC) patients which increases overall survival in the long term. Improvements in treatment planning and delivery and a greater understanding of BC behaviour have laid the groundwork for high-precision radiotherapy, which is bound to further improve the therapeutic index. Precise identification of target volumes, better coverage and dose homogeneity have had a positive impact on toxicity and local control. The conformity of treatment dose due to three-dimensional radiotherapy and new techniques such as intensity modulated radiotherapy makes it possible to spare surrounding normal tissue. The widespread use of dose-volume constraints and histograms have increased awareness of toxicity. Real time image guidance has improved geometric precision and accuracy, together with the implementation of quality assurance programs. Advances in the precision of radiotherapy is also based on the choice of the appropriate fractionation and approach. Adaptive radiotherapy is not only a technical concept, but is also a biological concept based on the knowledge that different types of BC have distinctive patterns of locoregional spread. A greater understanding of cancer biology helps in choosing the treatment best suited to a particular situation. Biomarkers predictive of response play a crucial role. The combination of radiotherapy with molecular targeted therapies may enhance radiosensitivity, thus increasing the cytotoxic effects and improving treatment response. The appropriateness of an alternative fractionation, partial breast irradiation, dose escalating/de-escalating approaches, the extent of nodal irradiation have been examined for all the BC subtypes. The broadened concept of adaptive radiotherapy is vital to high-precision treatments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Precision machining commercialization

    International Nuclear Information System (INIS)

    1978-01-01

    To accelerate precision machining development so as to realize more of the potential savings within the next few years of known Department of Defense (DOD) part procurement, the Air Force Materials Laboratory (AFML) is sponsoring the Precision Machining Commercialization Project (PMC). PMC is part of the Tri-Service Precision Machine Tool Program of the DOD Manufacturing Technology Five-Year Plan. The technical resources supporting PMC are provided under sponsorship of the Department of Energy (DOE). The goal of PMC is to minimize precision machining development time and cost risk for interested vendors. PMC will do this by making available the high precision machining technology as developed in two DOE contractor facilities, the Lawrence Livermore Laboratory of the University of California and the Union Carbide Corporation, Nuclear Division, Y-12 Plant, at Oak Ridge, Tennessee

  18. Advanced testing and validation centre gets electric vehicle technology to market faster

    Energy Technology Data Exchange (ETDEWEB)

    Astil, T.; Girard, F. [National Research Council of Canada, Vancouver, BC (Canada). Inst. for Fuel Cell Innovation

    2010-07-01

    The National Research Council (NRC) Institute for Fuel Cell Innovation is advancing Canada's clean energy advantage through NRC's technology cluster initiatives, which help Canadian small and medium enterprises achieve commercialization breakthroughs in key sectors. This presentation discussed the technology evaluation program (TEP) offered by the NRC Institute for Fuel Cell Innovation. The presentation discussed the TEPs mission, advanced testing and validation centre (ATVC), previous ATVC clients, environmental chamber, dynamometer, vibration table, electrochemical battery testing, and electrochemical testing laboratory. The ATVC is a specialized and safe environment for objective, reliable and accurate standardized testing applications of electric vehicle technologies. It offers independent test services to external organizations, making it easier to prove that electric vehicle technologies will perform under specific operating conditions. figs.

  19. [Care with the child's health and validation of an educational technology for riverside families].

    Science.gov (United States)

    Teixeira, Elizabeth; de Almeida Siqueira, Aldo; da Silva, Joselice Pereira; Lavor, Lília Cunha

    2011-01-01

    This study aimed to assess the knowledge and ways of caring for the child health 0-5 years between riverine (Phase 1), and to validate an educational technology (Phase 2). It was carried out a descriptive qualitative study. With the mothers, focus groups and content analysis were used, and with judges-specialists and target-public-applied, forms. The study revealed that the concern with the care of a child between the riverine families permeates the adversity daily, with dedication and commitment of these families in maintaining the health of their children. The sensitivity listening of mothers indicated the need for a closer relationship between nursing professionals and family. The validation of the educational technology was convergent, within the parameters considered adequate.

  20. Validation of innovative technologies and strategies for regulatory safety assessment methods: challenges and opportunities.

    Science.gov (United States)

    Stokes, William S; Wind, Marilyn

    2010-01-01

    Advances in science and innovative technologies are providing new opportunities to develop test methods and strategies that may improve safety assessments and reduce animal use for safety testing. These include high throughput screening and other approaches that can rapidly measure or predict various molecular, genetic, and cellular perturbations caused by test substances. Integrated testing and decision strategies that consider multiple types of information and data are also being developed. Prior to their use for regulatory decision-making, new methods and strategies must undergo appropriate validation studies to determine the extent that their use can provide equivalent or improved protection compared to existing methods and to determine the extent that reproducible results can be obtained in different laboratories. Comprehensive and optimal validation study designs are expected to expedite the validation and regulatory acceptance of new test methods and strategies that will support improved safety assessments and reduced animal use for regulatory testing.

  1. Validation study in four health-care databases: upper gastrointestinal bleeding misclassification affects precision but not magnitude of drug-related upper gastrointestinal bleeding risk.

    Science.gov (United States)

    Valkhoff, Vera E; Coloma, Preciosa M; Masclee, Gwen M C; Gini, Rosa; Innocenti, Francesco; Lapi, Francesco; Molokhia, Mariam; Mosseveld, Mees; Nielsson, Malene Schou; Schuemie, Martijn; Thiessard, Frantz; van der Lei, Johan; Sturkenboom, Miriam C J M; Trifirò, Gianluca

    2014-08-01

    To evaluate the accuracy of disease codes and free text in identifying upper gastrointestinal bleeding (UGIB) from electronic health-care records (EHRs). We conducted a validation study in four European electronic health-care record (EHR) databases such as Integrated Primary Care Information (IPCI), Health Search/CSD Patient Database (HSD), ARS, and Aarhus, in which we identified UGIB cases using free text or disease codes: (1) International Classification of Disease (ICD)-9 (HSD, ARS); (2) ICD-10 (Aarhus); and (3) International Classification of Primary Care (ICPC) (IPCI). From each database, we randomly selected and manually reviewed 200 cases to calculate positive predictive values (PPVs). We employed different case definitions to assess the effect of outcome misclassification on estimation of risk of drug-related UGIB. PPV was 22% [95% confidence interval (CI): 16, 28] and 21% (95% CI: 16, 28) in IPCI for free text and ICPC codes, respectively. PPV was 91% (95% CI: 86, 95) for ICD-9 codes and 47% (95% CI: 35, 59) for free text in HSD. PPV for ICD-9 codes in ARS was 72% (95% CI: 65, 78) and 77% (95% CI: 69, 83) for ICD-10 codes (Aarhus). More specific definitions did not have significant impact on risk estimation of drug-related UGIB, except for wider CIs. ICD-9-CM and ICD-10 disease codes have good PPV in identifying UGIB from EHR; less granular terminology (ICPC) may require additional strategies. Use of more specific UGIB definitions affects precision, but not magnitude, of risk estimates. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. High-speed scanning stroboscopic fringe-pattern projection technology for three-dimensional shape precision measurement.

    Science.gov (United States)

    Yang, Guowei; Sun, Changku; Wang, Peng; Xu, Yixin

    2014-01-10

    A high-speed scanning stroboscopic fringe-pattern projection system is designed. A high-speed rotating polygon mirror and a line-structured laser cooperate to produce stable and unambiguous stroboscopic fringe patterns. The system combines the rapidity of the grating projection with the high accuracy of the line-structured laser light source. The fringe patterns have fast frame rate, great density, high precision, and high brightness, with convenience and accuracy in adjusting brightness, frequency, linewidth, and the amount of phase shift. The characteristics and the stability of this system are verified by experiments. Experimental results show that the finest linewidth can reach 40 μm and that the minimum fringe cycle is 80 μm. Circuit modulation makes the light source system flexibly adjustable, easy to control in real time, and convenient to project various fringe patterns. Combined with different light intensity adjustment algorithms and 3D computation models, the 3D topography with high accuracy can be obtained for objects measured under different environments or objects with different sizes, morphologies, and optical properties. The proposed system shows a broad application prospect for fast 3D shape precision measurements, particularly in the industrial field of 3D online detection for precision devices.

  3. Why precision?

    Energy Technology Data Exchange (ETDEWEB)

    Bluemlein, Johannes

    2012-05-15

    Precision measurements together with exact theoretical calculations have led to steady progress in fundamental physics. A brief survey is given on recent developments and current achievements in the field of perturbative precision calculations in the Standard Model of the Elementary Particles and their application in current high energy collider data analyses.

  4. Why precision?

    International Nuclear Information System (INIS)

    Bluemlein, Johannes

    2012-05-01

    Precision measurements together with exact theoretical calculations have led to steady progress in fundamental physics. A brief survey is given on recent developments and current achievements in the field of perturbative precision calculations in the Standard Model of the Elementary Particles and their application in current high energy collider data analyses.

  5. A goal-based approach for qualification of new technologies: Foundations, tool support, and industrial validation

    International Nuclear Information System (INIS)

    Sabetzadeh, Mehrdad; Falessi, Davide; Briand, Lionel; Di Alesio, Stefano

    2013-01-01

    New technologies typically involve innovative aspects that are not addressed by the existing normative standards and hence are not assessable through common certification procedures. To ensure that new technologies can be implemented in a safe and reliable manner, a specific kind of assessment is performed, which in many industries, e.g., the energy sector, is known as Technology Qualification (TQ). TQ aims at demonstrating with an acceptable level of confidence that a new technology will function within specified limits. Expert opinion plays an important role in TQ, both to identify the safety and reliability evidence that needs to be developed and to interpret the evidence provided. Since there are often multiple experts involved in TQ, it is crucial to apply a structured process for eliciting expert opinions, and to use this information systematically when analyzing the satisfaction of the technology's safety and reliability objectives. In this paper, we present a goal-based approach for TQ. Our approach enables analysts to quantitatively reason about the satisfaction of the technology's overall goals and further to identify the aspects that must be improved to increase goal satisfaction. The approach is founded on three main components: goal models, expert elicitation, and probabilistic simulation. We describe a tool, named Modus, that we have developed in support of our approach. We provide an extensive empirical validation of our approach through two industrial case studies and a survey

  6. Instrument for assessing mobile technology acceptability in diabetes self-management: a validation and reliability study.

    Science.gov (United States)

    Frandes, Mirela; Deiac, Anca V; Timar, Bogdan; Lungeanu, Diana

    2017-01-01

    Nowadays, mobile technologies are part of everyday life, but the lack of instruments to assess their acceptability for the management of chronic diseases makes their actual adoption for this purpose slow. The objective of this study was to develop a survey instrument for assessing patients' attitude toward and intention to use mobile technology for diabetes mellitus (DM) self-management, as well as to identify sociodemographic characteristics and quality of life factors that affect them. We first conducted the documentation and instrument design phases, which were subsequently followed by the pilot study and instrument validation. Afterward, the instrument was administered 103 patients (median age: 37 years; range: 18-65 years) diagnosed with type 1 or type 2 DM, who accepted to participate in the study. The reliability and construct validity were assessed by computing Cronbach's alpha and using factor analysis, respectively. The instrument included statements about the actual use of electronic devices for DM management, interaction between patient and physician, attitude toward using mobile technology, and quality of life evaluation. Cronbach's alpha was 0.9 for attitude toward using mobile technology and 0.97 for attitude toward using mobile device applications for DM self-management. Younger patients (Spearman's ρ =-0.429; P higher education level (Kendall's τ =0.51; P mobile assistive applications for DM control. Moreover, patients with a higher quality of life presented a significantly more positive attitude toward using modern technology (Spearman's ρ =0.466; P mobile technology for DM self-management. Additionally, we found that even if most of the patients showed positive attitude toward mobile applications, only a moderate level of intention to indeed use them was observed. Moreover, the study indicated that barriers were truthfulness and easiness to use.

  7. Developing and validating a new precise risk-prediction model for new-onset hypertension: The Jichi Genki hypertension prediction model (JG model).

    Science.gov (United States)

    Kanegae, Hiroshi; Oikawa, Takamitsu; Suzuki, Kenji; Okawara, Yukie; Kario, Kazuomi

    2018-03-31

    No integrated risk assessment tools that include lifestyle factors and uric acid have been developed. In accordance with the Industrial Safety and Health Law in Japan, a follow-up examination of 63 495 normotensive individuals (mean age 42.8 years) who underwent a health checkup in 2010 was conducted every year for 5 years. The primary endpoint was new-onset hypertension (systolic blood pressure [SBP]/diastolic blood pressure [DBP] ≥ 140/90 mm Hg and/or the initiation of antihypertensive medications with self-reported hypertension). During the mean 3.4 years of follow-up, 7402 participants (11.7%) developed hypertension. The prediction model included age, sex, body mass index (BMI), SBP, DBP, low-density lipoprotein cholesterol, uric acid, proteinuria, current smoking, alcohol intake, eating rate, DBP by age, and BMI by age at baseline and was created by using Cox proportional hazards models to calculate 3-year absolute risks. The derivation analysis confirmed that the model performed well both with respect to discrimination and calibration (n = 63 495; C-statistic = 0.885, 95% confidence interval [CI], 0.865-0.903; χ 2 statistic = 13.6, degree of freedom [df] = 7). In the external validation analysis, moreover, the model performed well both in its discrimination and calibration characteristics (n = 14 168; C-statistic = 0.846; 95%CI, 0.775-0.905; χ 2 statistic = 8.7, df = 7). Adding LDL cholesterol, uric acid, proteinuria, alcohol intake, eating rate, and BMI by age to the base model yielded a significantly higher C-statistic, net reclassification improvement (NRI), and integrated discrimination improvement, especially NRI non-event (NRI = 0.127, 95%CI = 0.100-0.152; NRI non-event  = 0.108, 95%CI = 0.102-0.117). In conclusion, a highly precise model with good performance was developed for predicting incident hypertension using the new parameters of eating rate, uric acid, proteinuria, and BMI by age. ©2018 Wiley Periodicals, Inc.

  8. PrediCTC, liquid biopsy in precision oncology: a technology transfer experience in the Spanish health system.

    Science.gov (United States)

    Alonso-Alconada, L; Barbazan, J; Candamio, S; Falco, J L; Anton, C; Martin-Saborido, C; Fuster, G; Sampedro, M; Grande, C; Lado, R; Sampietro-Colom, L; Crego, E; Figueiras, S; Leon-Mateos, L; Lopez-Lopez, R; Abal, M

    2018-05-01

    Management of metastatic disease in oncology includes monitoring of therapy response principally by imaging techniques like CT scan. In addition to some limitations, the irruption of liquid biopsy and its application in personalized medicine has encouraged the development of more efficient technologies for prognosis and follow-up of patients in advanced disease. PrediCTC constitutes a panel of genes for the assessment of circulating tumor cells (CTC) in metastatic colorectal cancer patients, with demonstrated improved efficiency compared to CT scan for the evaluation of early therapy response in a multicenter prospective study. In this work, we designed and developed a technology transfer strategy to define the market opportunity for an eventual implementation of PrediCTC in the clinical practice. This included the definition of the regulatory framework, the analysis of the regulatory roadmap needed for CE mark, a benchmarking study, the design of a product development strategy, a revision of intellectual property, a cost-effectiveness study and an expert panel consultation. The definition and analysis of an appropriate technology transfer strategy and the correct balance among regulatory, financial and technical determinants are critical for the transformation of a promising technology into a viable technology, and for the decision of implementing liquid biopsy in the monitoring of therapy response in advanced disease.

  9. Demonstration of Helicopter Multi-Sensor Towed Array Detection System (MTADS) Magnetometry Technology at Victorville Precision Bombing Range, California

    Science.gov (United States)

    2008-09-12

    measurement Fluxgate magnetometer 10 RS232- ASCII SerialDevice.fluxgate Provides redundant aircraft attitude measurement Acoustic altimeters 10 Analog...primarily by terrain, vegetation, and structural inhibitions to safe low-altitude flight. The magnetometer data can be analyzed to extract either...to validate the results of the magnetometer survey. ESTCP Victorville PBR WAA Final Report December 2008 Sky Research, Inc. 2 1.2. Objectives of

  10. Development and Validation of Web-Based Courseware for Junior Secondary School Basic Technology Students in Nigeria

    Directory of Open Access Journals (Sweden)

    Amosa Isiaka Gambari

    2018-02-01

    Full Text Available This research aimed to develop and validate a web-based courseware for junior secondary school basic technology students in Nigeria. In this study, a mixed method quantitative pilot study design with qualitative components was used to test and ascertain the ease of development and validation of the web-based courseware. Dick and Carey instructional system design model was adopted for developing the courseware. Convenience sampling technique was used in selecting the three content, computer and educational technology experts to validate the web-based courseware. Non-randomized and non-equivalent Junior secondary school students from two schools were used for field trial validation. Four validating instruments were employed in conducting this study: (i Content Validation Assessment Report (CVAR; (ii Computer Expert Validation Assessment Report (CEAR; (iii Educational Technology Experts Validation Assessment Report (ETEVAR; and (iv Students Validation Questionnaire (SVQ. All the instruments were face and content validated. SVQ was pilot tested and reliability coefficient of 0.85 was obtained using Cronbach Alpha. CVAR, CEAR, ETEVAR were administered on content specialists, computer experts, and educational technology experts, while SVQ was administered on 83 JSS students from two selected secondary schools in Minna. The findings revealed that the process of developing web-based courseware using Dick and Carey Instructional System Design was successful. In addition, the report from the validating team revealed that the web-based courseware is valuable for learning basic technology. It is therefore recommended that web-based courseware should be produced to teach basic technology concepts on large scale.

  11. The validity of visual acuity assessment using mobile technology devices in the primary care setting.

    Science.gov (United States)

    O'Neill, Samuel; McAndrew, Darryl J

    2016-04-01

    The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.

  12. International comparison of methods to test the validity of dead-time and pile-up corrections for high-precision. gamma. -ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Houtermans, H.; Schaerf, K.; Reichel, F. (International Atomic Energy Agency, Vienna (Austria)); Debertin, K. (Physikalisch-Technische Bundesanstalt, Braunschweig (Germany, F.R.))

    1983-02-01

    The International Atomic Energy Agency organized an international comparison of methods applied in high-precision ..gamma..-ray spectrometry for the correction of dead-time and pile-up losses. Results of this comparison are reported and discussed.

  13. Cost-Effective ISS Space-Environment Technology Validation of Advanced Roll-Out Solar Array (ROSA), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — DSS proposes to systematically mature, mitigate risk for; and perform hardware-based ground validations / demonstrations of a low-cost, high technology payoff,...

  14. Identifying Health Information Technology Needs of Oncologists to Facilitate the Adoption of Genomic Medicine: Recommendations From the 2016 American Society of Clinical Oncology Omics and Precision Oncology Workshop.

    Science.gov (United States)

    Hughes, Kevin S; Ambinder, Edward P; Hess, Gregory P; Yu, Peter Paul; Bernstam, Elmer V; Routbort, Mark J; Clemenceau, Jean Rene; Hamm, John T; Febbo, Phillip G; Domchek, Susan M; Chen, James L; Warner, Jeremy L

    2017-09-20

    At the ASCO Data Standards and Interoperability Summit held in May 2016, it was unanimously decided that four areas of current oncology clinical practice have serious, unmet health information technology needs. The following areas of need were identified: 1) omics and precision oncology, 2) advancing interoperability, 3) patient engagement, and 4) value-based oncology. To begin to address these issues, ASCO convened two complementary workshops: the Omics and Precision Oncology Workshop in October 2016 and the Advancing Interoperability Workshop in December 2016. A common goal was to address the complexity, enormity, and rapidly changing nature of genomic information, which existing electronic health records are ill equipped to manage. The subject matter experts invited to the Omics and Precision Oncology Workgroup were tasked with the responsibility of determining a specific, limited need that could be addressed by a software application (app) in the short-term future, using currently available genomic knowledge bases. Hence, the scope of this workshop was to determine the basic functionality of one app that could serve as a test case for app development. The goal of the second workshop, described separately, was to identify the specifications for such an app. This approach was chosen both to facilitate the development of a useful app and to help ASCO and oncologists better understand the mechanics, difficulties, and gaps in genomic clinical decision support tool development. In this article, we discuss the key challenges and recommendations identified by the workshop participants. Our hope is to narrow the gap between the practicing oncologist and ongoing national efforts to provide precision oncology and value-based care to cancer patients.

  15. Application of high-precision 3D seismic technology to shale gas exploration: A case study of the large Jiaoshiba shale gas field in the Sichuan Basin

    Directory of Open Access Journals (Sweden)

    Zuqing Chen

    2016-03-01

    Full Text Available The accumulation pattern of the marine shale gas in South China is different from that in North America. The former has generally thin reservoirs and complex preservation conditions, so it is difficult to make a fine description of the structural features of shale formations and to reflect accurately the distribution pattern of high-quality shale by using the conventional 2D and 3D seismic exploration technology, which has an adverse effect on the successful deployment of horizontal wells. In view of this, high-precision 3D seismic prospecting focusing on lithological survey was implemented to make an accurate description of the distribution of shale gas sweet spots so that commercial shale gas production can be obtained. Therefore, due to the complex seismic geological condition of Jiaoshiba area in Fuling, SE Sichuan Basin, the observation system of high-precision 3D seismic acquisition should have such features as wide-azimuth angles, small trace intervals, high folds, uniform vertical and horizontal coverage and long spread to meet the needs of the shale gas exploration in terms of structural interpretation, lithological interpretation and fracture prediction. Based on this idea, the first implemented high-precision 3D seismic exploration project in Jiaoshiba area played an important role in the discovery of the large Jiaoshiba shale gas field. Considering that the high-quality marine shale in the Sichuan Basin shows the characteristics of multi-layer development from the Silurian system to the Cambrian system, the strategy of shale gas stereoscopic exploration should be implemented to fully obtain the oil and gas information of the shallow, medium and deep strata from the high-precision 3D seismic data, and ultimately to expand the prospecting achievements in an all-round way to balance the high upstream exploration cost, and to continue to push the efficient shale gas exploration and development process in China.

  16. Simulação na validação de sistemas computacionais para a agricultura de precisão Simulation in the validation of precision farming computing systems

    Directory of Open Access Journals (Sweden)

    Braulio A. de Mello

    2008-12-01

    Full Text Available Sistemas computacionais têm tido aplicação crescente na construção de sistemas para o setor agrícola; contudo, o trabalho de projeto desse tipo de sistemas tem-se tornado mais complexo devido à necessidade de se estabelecer cooperação entre componentes que não possuem uma interface comum e/ou construídos com tecnologias diferentes (heterogêneos; deste modo, os componentes são, geralmente, validados em separado e a observação do funcionamento do sistema completo ocorre somente nos testes com o uso de protótipos, retardando a identificação de problemas e gerando custos em tempo e recursos. O uso da simulação pode contribuir com a antecipação de experiências que permitam observar o comportamento da cooperação entre os componentes do sistema, com o objetivo de reduzir o tempo e o custo geral do projeto. Através de um sistema eletrônico de supervisão de plantio (SEP como estudo de caso, o artigo apresenta o uso do DCB (Distributed Cosimulation Backbone como ferramenta de modelagem e simulação de sistemas voltados para a agricultura de precisão para reduzir tempo e custos de projeto.Computing systems have been employed for agricultural purposes, mainly in the precision farming domain. However, their implementation is complex because the cooperation among system components formed by agricultural equipment and computing parts do not have a common interface and the components are developed over distinct technologies (heterogeneous components. Also, the components are individually validated and the cooperation among them can be observed only in experiments using prototypes, delaying the identification of errors and increasing general costs. Simulation techniques are used to observe the work of all systems using models. This paper discusses a heterogeneous simulation to improve the implementation process of precision agricultural systems that bind heterogeneous components. This article presents a solution based on DCB

  17. Validation and Assessment of a Technology Familiarity Score in Patients Attending a Symptomatic Breast Clinic.

    Science.gov (United States)

    O'Brien, C; Kelly, J; Lehane, E A; Livingstone, V; Cotter, B; Butt, A; Kelly, L; Corrigan, M A

    2015-10-01

    New media technologies (computers, mobile phones and the internet) have the potential to transform the healthcare information needs of patients with breast disease (Ferlay et al. in Eur J Cancer 49:1374-1403, 2013). However, patients' current level of use and their willingness to accept new media for education and communication remain unknown. This was a single-centre clinic-based prospective cross-sectional study. A previously developed instrument was modified, validated and tested on patients attending a symptomatic breast clinic. The instrument was evaluated on 200 symptomatic breast patients. The commonest outlets for education were staff (95 %), leaflets (69 %) and websites (59 %). Websites are more likely to be consulted by younger patients (higher education were more likely to favour apps, websites and email (p technology use among breast patients is expanding as expected along generational trends. As such its' further integration into healthcare systems can potentially ameliorate patient education and communication.

  18. Drivers for precision livestock technology adoption: A study of factors associated with adoption of electronic identification technology by commercial sheep farmers in England and Wales.

    Science.gov (United States)

    Lima, Eliana; Hopkins, Thomas; Gurney, Emma; Shortall, Orla; Lovatt, Fiona; Davies, Peers; Williamson, George; Kaler, Jasmeet

    2018-01-01

    The UK is the largest lamb meat producer in Europe. However, the low profitability of sheep farming sector suggests production efficiency could be improved. Although the use of technologies such as Electronic Identification (EID) tools could allow a better use of flock resources, anecdotal evidence suggests they are not widely used. The aim of this study was to assess uptake of EID technology, and explore drivers and barriers of adoption of related tools among English and Welsh farmers. Farm beliefs and management practices associated with adoption of this technology were investigated. A total of 2000 questionnaires were sent, with a response rate of 22%. Among the respondents, 87 had adopted EID tools for recording flock information, 97 intended to adopt it in the future, and 222 neither had adopted it, neither intended to adopt it. Exploratory factor analysis (EFA) and multivariable logistic regression modelling were used to identify farmer beliefs and management practices significantly associated with adoption of EID technology. EFA identified three factors expressing farmer's beliefs-external pressure and negative feelings, usefulness and practicality. Our results suggest farmer's beliefs play a significant role in technology uptake. Non-adopters were more likely than adopters to believe that 'government pressurise farmers to adopt technology'. In contrast, adopters were significantly more likely than non-adopters to see EID as practical and useful (p≤0.05). Farmers with higher information technologies literacy and intending to intensify production in the future were significantly more likely to adopt EID technology (p≤0.05). Importantly, flocks managed with EID tools had significantly lower farmer- reported flock lameness levels (p≤0.05). These findings bring insights on the dynamics of adoption of EID tools. Communicating evidence of the positive effects EID tools on flock performance and strengthening farmer's capability in use of technology are likely

  19. The Theory of Planned Behavior (TPB) and Pre-Service Teachers' Technology Acceptance: A Validation Study Using Structural Equation Modeling

    Science.gov (United States)

    Teo, Timothy; Tan, Lynde

    2012-01-01

    This study applies the theory of planned behavior (TPB), a theory that is commonly used in commercial settings, to the educational context to explain pre-service teachers' technology acceptance. It is also interested in examining its validity when used for this purpose. It has found evidence that the TPB is a valid model to explain pre-service…

  20. Drivers for precision livestock technology adoption: A study of factors associated with adoption of electronic identification technology by commercial sheep farmers in England and Wales

    Science.gov (United States)

    Hopkins, Thomas; Gurney, Emma; Shortall, Orla; Lovatt, Fiona; Davies, Peers; Williamson, George; Kaler, Jasmeet

    2018-01-01

    The UK is the largest lamb meat producer in Europe. However, the low profitability of sheep farming sector suggests production efficiency could be improved. Although the use of technologies such as Electronic Identification (EID) tools could allow a better use of flock resources, anecdotal evidence suggests they are not widely used. The aim of this study was to assess uptake of EID technology, and explore drivers and barriers of adoption of related tools among English and Welsh farmers. Farm beliefs and management practices associated with adoption of this technology were investigated. A total of 2000 questionnaires were sent, with a response rate of 22%. Among the respondents, 87 had adopted EID tools for recording flock information, 97 intended to adopt it in the future, and 222 neither had adopted it, neither intended to adopt it. Exploratory factor analysis (EFA) and multivariable logistic regression modelling were used to identify farmer beliefs and management practices significantly associated with adoption of EID technology. EFA identified three factors expressing farmer’s beliefs–external pressure and negative feelings, usefulness and practicality. Our results suggest farmer’s beliefs play a significant role in technology uptake. Non-adopters were more likely than adopters to believe that ‘government pressurise farmers to adopt technology’. In contrast, adopters were significantly more likely than non-adopters to see EID as practical and useful (p≤0.05). Farmers with higher information technologies literacy and intending to intensify production in the future were significantly more likely to adopt EID technology (p≤0.05). Importantly, flocks managed with EID tools had significantly lower farmer- reported flock lameness levels (p≤0.05). These findings bring insights on the dynamics of adoption of EID tools. Communicating evidence of the positive effects EID tools on flock performance and strengthening farmer’s capability in use of

  1. Validating a measure to assess factors that affect assistive technology use by students with disabilities in elementary and secondary education.

    Science.gov (United States)

    Zapf, Susan A; Scherer, Marcia J; Baxter, Mary F; H Rintala, Diana

    2016-01-01

    The purpose of this study was to measure the predictive validity, internal consistency and clinical utility of the Matching Assistive Technology to Child & Augmentative Communication Evaluation Simplified (MATCH-ACES) assessment. Twenty-three assistive technology team evaluators assessed 35 children using the MATCH-ACES assessment. This quasi-experimental study examined the internal consistency, predictive validity and clinical utility of the MATCH-ACES assessment. The MATCH-ACES assessment predisposition scales had good internal consistency across all three scales. A significant relationship was found between (a) high student perseverance and need for assistive technology and (b) high teacher comfort and interest in technology use (p = (0).002). Study results indicate that the MATCH-ACES assessment has good internal consistency and validity. Predisposition characteristics of student and teacher combined can influence the level of assistive technology use; therefore, assistive technology teams should assess predisposition factors of the user when recommending assistive technology. Implications for Rehabilitation Educational and medical professionals should be educated on evidence-based assistive technology assessments. Personal experience and psychosocial factors can influence the outcome use of assistive technology. Assistive technology assessments must include an intervention plan for assistive technology service delivery to measure effective outcome use.

  2. Narrow microtunnel technology for the isolation and precise identification of axonal communication among distinct hippocampal subregion networks.

    Directory of Open Access Journals (Sweden)

    Udit Narula

    Full Text Available Communication between different sub regions of the hippocampus is fundamental to learning and memory. However accurate knowledge about information transfer between sub regions from access to the activity in individual axons is lacking. MEMS devices with microtunnels connecting two sub networks have begun to approach this problem but the commonly used 10 μm wide tunnels frequently measure signals from multiple axons. To reduce this complexity, we compared polydimethylsiloxane (PDMS microtunnel devices each with a separate tunnel width of 2.5, 5 or 10 μm bridging two wells aligned over a multi electrode array (MEA. Primary rat neurons were grown in the chambers with neurons from the dentate gyrus on one side and hippocampal CA3 on the other. After 2-3 weeks of culture, spontaneous activity in the axons inside the tunnels was recorded. We report electrophysiological, exploratory data analysis for feature clustering and visual evidence to support the expectation that 2.5 μm wide tunnels have fewer axons per tunnel and therefore more clearly delineated signals than 10 or 5 μm wide tunnels. Several measures indicated that fewer axons per electrode enabled more accurate detection of spikes. A clustering analysis comparing the variations of spike height and width for different tunnel widths revealed tighter clusters representing unique spikes with less height and width variation when measured in narrow tunnels. Wider tunnels tended toward more diffuse clusters from a continuum of spike heights and widths. Standard deviations for multiple cluster measures, such as Average Dissimilarity, Silhouette Value (S and Separation Factor (average dissimilarity/S value, support a conclusion that 2.5 μm wide tunnels containing fewer axons enable more precise determination of individual action potential peaks, their propagation direction, timing, and information transfer between sub networks.

  3. Using smartphone technology to deliver a virtual pedestrian environment: usability and validation.

    Science.gov (United States)

    Schwebel, David C; Severson, Joan; He, Yefei

    2017-09-01

    Various programs effectively teach children to cross streets more safely, but all are labor- and cost-intensive. Recent developments in mobile phone technology offer opportunity to deliver virtual reality pedestrian environments to mobile smartphone platforms. Such an environment may offer a cost- and labor-effective strategy to teach children to cross streets safely. This study evaluated usability, feasibility, and validity of a smartphone-based virtual pedestrian environment. A total of 68 adults completed 12 virtual crossings within each of two virtual pedestrian environments, one delivered by smartphone and the other a semi-immersive kiosk virtual environment. Participants completed self-report measures of perceived realism and simulator sickness experienced in each virtual environment, plus self-reported demographic and personality characteristics. All participants followed system instructions and used the smartphone-based virtual environment without difficulty. No significant simulator sickness was reported or observed. Users rated the smartphone virtual environment as highly realistic. Convergent validity was detected, with many aspects of pedestrian behavior in the smartphone-based virtual environment matching behavior in the kiosk virtual environment. Anticipated correlations between personality and kiosk virtual reality pedestrian behavior emerged for the smartphone-based system. A smartphone-based virtual environment can be usable and valid. Future research should develop and evaluate such a training system.

  4. Validation test of advanced technology for IPV nickel-hydrogen flight cells: Update

    Science.gov (United States)

    Smithrick, John J.; Hall, Stephen W.

    1992-01-01

    Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the low-earth-orbit (LEO) cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing at the Naval Weapons Support Center (NWSC), Crane, Indiana under a NASA Lewis Contract. An advanced 125 Ah IPV nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion. The advanced cell design is in the process of being validated using real time LEO cycle life testing of NWSC, Crane, Indiana. An update of validation test results confirming this technology is presented.

  5. Validation of the Leap Motion Controller using markered motion capture technology.

    Science.gov (United States)

    Smeragliuolo, Anna H; Hill, N Jeremy; Disla, Luis; Putrino, David

    2016-06-14

    The Leap Motion Controller (LMC) is a low-cost, markerless motion capture device that tracks hand, wrist and forearm position. Integration of this technology into healthcare applications has begun to occur rapidly, making validation of the LMC׳s data output an important research goal. Here, we perform a detailed evaluation of the kinematic data output from the LMC, and validate this output against gold-standard, markered motion capture technology. We instructed subjects to perform three clinically-relevant wrist (flexion/extension, radial/ulnar deviation) and forearm (pronation/supination) movements. The movements were simultaneously tracked using both the LMC and a marker-based motion capture system from Motion Analysis Corporation (MAC). Adjusting for known inconsistencies in the LMC sampling frequency, we compared simultaneously acquired LMC and MAC data by performing Pearson׳s correlation (r) and root mean square error (RMSE). Wrist flexion/extension and radial/ulnar deviation showed good overall agreement (r=0.95; RMSE=11.6°, and r=0.92; RMSE=12.4°, respectively) with the MAC system. However, when tracking forearm pronation/supination, there were serious inconsistencies in reported joint angles (r=0.79; RMSE=38.4°). Hand posture significantly influenced the quality of wrist deviation (P<0.005) and forearm supination/pronation (P<0.001), but not wrist flexion/extension (P=0.29). We conclude that the LMC is capable of providing data that are clinically meaningful for wrist flexion/extension, and perhaps wrist deviation. It cannot yet return clinically meaningful data for measuring forearm pronation/supination. Future studies should continue to validate the LMC as updated versions of their software are developed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Impact of Recent Trends in Information and Communication Technology on the Validity of the Construct Information Literacy in Higher Education

    NARCIS (Netherlands)

    A.A.J. (Jos) van Helvoort

    2010-01-01

    The objective of this paper is a reflective discussion on the validity of the construct Information Literacy in the perspective of changing information and communication technologies. The research question that will be answered is: what is the impact of technological developments on the relevance of

  7. Development and validation of the computer technology literacy self-assessment scale for Taiwanese elementary school students.

    Science.gov (United States)

    Chang, Chiung-Sui

    2008-01-01

    The purpose of this study was to describe the development and validation of an instrument to identify various dimensions of the computer technology literacy self-assessment scale (CTLS) for elementary school students. The instrument included five CTLS dimensions (subscales): the technology operation skills, the computer usages concepts, the attitudes toward computer technology, the learning with technology, and the Internet operation skills. Participants were 1,539 elementary school students in Taiwan. Data analysis indicated that the instrument developed in the study had satisfactory validity and reliability. Correlations analysis supported the legitimacy of using multiple dimensions in representing students' computer technology literacy. Significant differences were found between male and female students, and between grades on some CTLS dimensions. Suggestions are made for use of the instrument to examine complicated interplays between students' computer behaviors and their computer technology literacy.

  8. Precision translator

    Science.gov (United States)

    Reedy, Robert P.; Crawford, Daniel W.

    1984-01-01

    A precision translator for focusing a beam of light on the end of a glass fiber which includes two turning fork-like members rigidly connected to each other. These members have two prongs each with its separation adjusted by a screw, thereby adjusting the orthogonal positioning of a glass fiber attached to one of the members. This translator is made of simple parts with capability to keep adjustment even in condition of rough handling.

  9. Validation of a Multimodality Flow Phantom and Its Application for Assessment of Dynamic SPECT and PET Technologies.

    Science.gov (United States)

    Gabrani-Juma, Hanif; Clarkin, Owen J; Pourmoghaddas, Amir; Driscoll, Brandon; Wells, R Glenn; deKemp, Robert A; Klein, Ran

    2017-01-01

    Simple and robust techniques are lacking to assess performance of flow quantification using dynamic imaging. We therefore developed a method to qualify flow quantification technologies using a physical compartment exchange phantom and image analysis tool. We validate and demonstrate utility of this method using dynamic PET and SPECT. Dynamic image sequences were acquired on two PET/CT and a cardiac dedicated SPECT (with and without attenuation and scatter corrections) systems. A two-compartment exchange model was fit to image derived time-activity curves to quantify flow rates. Flowmeter measured flow rates (20-300 mL/min) were set prior to imaging and were used as reference truth to which image derived flow rates were compared. Both PET cameras had excellent agreement with truth ( [Formula: see text]). High-end PET had no significant bias (p > 0.05) while lower-end PET had minimal slope bias (wash-in and wash-out slopes were 1.02 and 1.01) but no significant reduction in precision relative to high-end PET ( 0.3). SPECT (without scatter and attenuation corrections) slope biases were noted (0.85 and 1.32) and attributed to camera saturation in early time frames. Analysis of wash-out rates from non-saturated, late time frames resulted in excellent agreement with truth ( [Formula: see text], slope = 0.97). Attenuation and scatter corrections did not significantly impact SPECT performance. The proposed phantom, software and quality assurance paradigm can be used to qualify imaging instrumentation and protocols for quantification of kinetic rate parameters using dynamic imaging.

  10. Precision Cosmology

    Science.gov (United States)

    Jones, Bernard J. T.

    2017-04-01

    Preface; Notation and conventions; Part I. 100 Years of Cosmology: 1. Emerging cosmology; 2. The cosmic expansion; 3. The cosmic microwave background; 4. Recent cosmology; Part II. Newtonian Cosmology: 5. Newtonian cosmology; 6. Dark energy cosmological models; 7. The early universe; 8. The inhomogeneous universe; 9. The inflationary universe; Part III. Relativistic Cosmology: 10. Minkowski space; 11. The energy momentum tensor; 12. General relativity; 13. Space-time geometry and calculus; 14. The Einstein field equations; 15. Solutions of the Einstein equations; 16. The Robertson-Walker solution; 17. Congruences, curvature and Raychaudhuri; 18. Observing and measuring the universe; Part IV. The Physics of Matter and Radiation: 19. Physics of the CMB radiation; 20. Recombination of the primeval plasma; 21. CMB polarisation; 22. CMB anisotropy; Part V. Precision Tools for Precision Cosmology: 23. Likelihood; 24. Frequentist hypothesis testing; 25. Statistical inference: Bayesian; 26. CMB data processing; 27. Parametrising the universe; 28. Precision cosmology; 29. Epilogue; Appendix A. SI, CGS and Planck units; Appendix B. Magnitudes and distances; Appendix C. Representing vectors and tensors; Appendix D. The electromagnetic field; Appendix E. Statistical distributions; Appendix F. Functions on a sphere; Appendix G. Acknowledgements; References; Index.

  11. Combining novel monitoring tools and precision application technologies for integrated high-tech crop protection in the future (a discussion document).

    Science.gov (United States)

    Zijlstra, Carolien; Lund, Ivar; Justesen, Annemarie F; Nicolaisen, Mogens; Jensen, Peter Kryger; Bianciotto, Valeria; Posta, Katalin; Balestrini, Raffaella; Przetakiewicz, Anna; Czembor, Elzbieta; van de Zande, Jan

    2011-06-01

    The possibility of combining novel monitoring techniques and precision spraying for crop protection in the future is discussed. A generic model for an innovative crop protection system has been used as a framework. This system will be able to monitor the entire cropping system and identify the presence of relevant pests, diseases and weeds online, and will be location specific. The system will offer prevention, monitoring, interpretation and action which will be performed in a continuous way. The monitoring is divided into several parts. Planting material, seeds and soil should be monitored for prevention purposes before the growing period to avoid, for example, the introduction of disease into the field and to ensure optimal growth conditions. Data from previous growing seasons, such as the location of weeds and previous diseases, should also be included. During the growing season, the crop will be monitored at a macroscale level until a location that needs special attention is identified. If relevant, this area will be monitored more intensively at a microscale level. A decision engine will analyse the data and offer advice on how to control the detected diseases, pests and weeds, using precision spray techniques or alternative measures. The goal is to provide tools that are able to produce high-quality products with the minimal use of conventional plant protection products. This review describes the technologies that can be used or that need further development in order to achieve this goal. Copyright © 2011 Society of Chemical Industry.

  12. Polysomnographic validation of a wireless dry headband technology for sleep monitoring in healthy young adults.

    Science.gov (United States)

    Tonetti, Lorenzo; Cellini, Nicola; de Zambotti, Massimiliano; Fabbri, Marco; Martoni, Monica; Fábregas, Stephan E; Stegagno, Luciano; Natale, Vincenzo

    2013-06-13

    The present study aimed to explore the validity and reliability of a wireless dry headband technology for sleep monitoring (WS), through a comparison with concurrent polysomnographic (PSG) recording in healthy young adults. Eleven volunteers (7 females; mean age±SD: 24.75±3.62years) took part in the study, wearing the WS for two overnight PSG recordings in the sleep laboratory. The WS was compared to PSG in the identification of wake, light, deep and REM sleep. The WS sensitivity and specificity were 97.6% and 56.1%, respectively. The WS agreement with PSG, measured by Cohen's kappa, was 0.56 for light sleep, 0.70 for deep sleep, and 0.67 for REM sleep. The present results showed that the agreement ranged from moderate to high between PSG and the WS, while wakefulness detection was observed to be a limitation of the WS. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. CERESVis: A QC Tool for CERES that Leverages Browser Technology for Data Validation

    Science.gov (United States)

    Chu, C.; Sun-Mack, S.; Heckert, E.; Chen, Y.; Doelling, D.

    2015-12-01

    In this poster, we are going to present three user interfaces that CERES team uses to validate pixel-level data. Besides our home grown tools, we will aslo present the browser technology that we use to provide interactive interfaces, such as jquery, HighCharts and Google Earth. We pass data to the users' browsers and use the browsers to do some simple computations. The three user interfaces are: Thumbnails -- it displays hundrends images to allow users to browse 24-hour data files in few seconds. Multiple-synchronized cursors -- it allows users to compare multiple images side by side. Bounding Boxes and Histograms -- it allows users to draw multiple bounding boxes on an image and the browser computes/display the histograms.

  14. Development and validation of a predictive technology for creep closure of underground rooms in salt

    International Nuclear Information System (INIS)

    Munson, D.E.; DeVries, K.L.

    1991-07-01

    Because of the concern for public health and safety, when compared to normal engineering practice, radioactive waste repositories have quite unusual requirements governing performance assessment. In part, performance assessment requires prediction of time-dependent or creep response of the repository hundreds to thousands of years into the future. In salt, one specific need is to predict, with confidence, the time at which the repository rooms creep closed sufficiently to encapsulate the waste and seal the repository. Thus, a major task of the Waste Isolation Pilot Plant (WIPP) Program is to develop and validate this predictive technology to calculate creep of repository rooms in the bedded salt deposits of Southeastern New Mexico. 19 refs., 15 figs., 2 tabs

  15. Development and validation of science, technology, engineering and mathematics (STEM) based instructional material

    Science.gov (United States)

    Gustiani, Ineu; Widodo, Ari; Suwarma, Irma Rahma

    2017-05-01

    This study is intended to examine the development and validation of simple machines instructional material that developed based on Science, Technology, Engineering and Mathematics (STEM) framework that provides guidance to help students learn and practice for real life and enable individuals to use knowledge and skills they need to be an informed citizen. Sample of this study consist of one class of 8th grader at a junior secondary school in Bandung, Indonesia. To measure student learning, a pre-test and post-test were given before and after implementation of the STEM based instructional material. In addition, a questionnaire of readability was given to examine the clarity and difficulty level of each page of instructional material. A questionnaire of students' response towards instructional material given to students and teachers at the end of instructional material reading session to measure layout aspects, content aspects and utility aspects of instructional material for being used in the junior secondary school classroom setting. The results show that readability aspect and students' response towards STEM based instructional material of STEM based instructional material is categorized as very high. Pretest and posttest responses revealed that students retained significant amounts information upon completion of the STEM instructional material. Student overall learning gain is 0.67 which is categorized as moderate. In summary, STEM based instructional material that was developed is valid enough to be used as educational materials necessary for conducting effective STEM education.

  16. Multi-Evaporator Miniature Loop Heat Pipe for Small Spacecraft Thermal Control. Part 1; New Technologies and Validation Approach

    Science.gov (United States)

    Ku, Jentung; Ottenstein, Laura; Douglas, Donya; Hoang, Triem

    2010-01-01

    Under NASA s New Millennium Program Space Technology 8 (ST 8) Project, four experiments Thermal Loop, Dependable Microprocessor, SAILMAST, and UltraFlex - were conducted to advance the maturity of individual technologies from proof of concept to prototype demonstration in a relevant environment , i.e. from a technology readiness level (TRL) of 3 to a level of 6. This paper presents the new technologies and validation approach of the Thermal Loop experiment. The Thermal Loop is an advanced thermal control system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and multiple condensers designed for future small system applications requiring low mass, low power, and compactness. The MLHP retains all features of state-of-the-art loop heat pipes (LHPs) and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. Details of the thermal loop concept, technical advances, benefits, objectives, level 1 requirements, and performance characteristics are described. Also included in the paper are descriptions of the test articles and mathematical modeling used for the technology validation. An MLHP breadboard was built and tested in the laboratory and thermal vacuum environments for TRL 4 and TRL 5 validations, and an MLHP proto-flight unit was built and tested in a thermal vacuum chamber for the TRL 6 validation. In addition, an analytical model was developed to simulate the steady state and transient behaviors of the MLHP during various validation tests. Capabilities and limitations of the analytical model are also addressed.

  17. Precision Airdrop (Largage de precision)

    Science.gov (United States)

    2005-12-01

    NAVIGATION TO A PRECISION AIRDROP OVERVIEW RTO-AG-300-V24 2 - 9 the point from various compass headings. As the tests are conducted, the resultant...rate. This approach avoids including a magnetic compass for the heading reference, which has difficulties due to local changes in the magnetic field...Scientifica della Difesa ROYAUME-UNI Via XX Settembre 123 Dstl Knowledge Services ESPAGNE 00187 Roma Information Centre, Building 247 SDG TECEN / DGAM

  18. Automatic Validation of Protocol Narration

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Degano, Pierpablo

    2003-01-01

    We perform a systematic expansion of protocol narrations into terms of a process algebra in order to make precise some of the detailed checks that need to be made in a protocol. We then apply static analysis technology to develop an automatic validation procedure for protocols. Finally, we...

  19. California Diploma Project Technical Report III: Validity Study--Validity Study of the Health Sciences and Medical Technology Standards

    Science.gov (United States)

    McGaughy, Charis; Bryck, Rick; de Gonzalez, Alicia

    2012-01-01

    This study is a validity study of the recently revised version of the Health Science Standards. The purpose of this study is to understand how the Health Science Standards relate to college and career readiness, as represented by survey ratings submitted by entry-level college instructors of health science courses and industry representatives. For…

  20. Aircraft Loss of Control: Problem Analysis for the Development and Validation of Technology Solutions

    Science.gov (United States)

    Belcastro, Christine M.; Newman, Richard L.; Crider, Dennis A.; Klyde, David H.; Foster, John V.; Groff, Loren

    2016-01-01

    Aircraft loss of control (LOC) is a leading cause of fatal accidents across all transport airplane and operational classes. LOC can result from a wide spectrum of precursors (or hazards), often occurring in combination. Technologies developed for LOC prevention and recovery must therefore be effective under a wide variety of conditions and uncertainties, including multiple hazards, and the validation process must provide a means of assessing system effectiveness and coverage of these hazards. This paper provides a detailed description of a methodology for analyzing LOC as a dynamics and control problem for the purpose of developing effective technology solutions. The paper includes a definition of LOC based on several recent publications, a detailed description of a refined LOC accident analysis process that is illustrated via selected example cases, and a description of planned follow-on activities for identifying future potential LOC risks and the development of LOC test scenarios. Some preliminary considerations for LOC of Unmanned Aircraft Systems (UAS) and for their safe integration into the National Airspace System (NAS) are also discussed.

  1. Building, testing and validating a set of home-made von Frey filaments: a precise, accurate and cost effective alternative for nociception assessment.

    Science.gov (United States)

    de Sousa, Marcelo Victor Pires; Ferraresi, Cleber; de Magalhães, Ana Carolina; Yoshimura, Elisabeth Mateus; Hamblin, Michael R

    2014-07-30

    A von Frey filament (vFF) is a type of aesthesiometer usually made of nylon perpendicularly held in a base. It can be used in paw withdrawal pain threshold assessment, one of the most popular tests for pain evaluation using animal models. For this test, a set of filaments, each able to exert a different force, is applied to the animal paw, from the weakest to the strongest, until the paw is withdrawn. We made 20 low cost vFF using nylon filaments of different lengths and constant diameter glued perpendicularly to the ends of popsicle sticks. They were calibrated using a laboratory balance scale. Building and calibrating took around 4h and confirmed the theoretical prediction that the force exerted is inversely proportional to the length and directly proportional to the width of the filament. The calibration showed that they were precise and accurate. We analyzed the paw withdrawal threshold assessed with the set of home-made vFF and with a high quality commercial set of 5 monofilaments vFF (Stoelting, Wood Dale, USA) in two groups (n=5) of healthy mice. The home-made vFF precisely and accurately measured the hind paw withdrawal threshold (20.3±0.9 g). The commercial vFF have different diameters while our set has the same diameter avoiding the problem of lower sensitivity to larger diameter filaments. Building a set of vFF is easy, cost effective, and depending on the kind of tests, can increase precision and accuracy of animal nociception evaluation. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Dramatically improve the Safety Performance of Li ion Battery Separators and Reduce the Manufacturing Cost Using Ultraviolet Curing and High Precision Coating Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Voelker, Gary [Miltec UV International, LLC, Stevensville, MD (United States); Arnold, John [Miltec UV International, LLC, Stevensville, MD (United States)

    2017-06-30

    The objective of this project was to improve the safety of operation of Lithium ion batteries (LIB)and at the same time significantly reduce the manufacturing cost of LIB separators. The project was very successful in demonstrating the improved performance and reduced cost attributed to using UV curable binder and high speed printing technology to place a very thin and precisely controlled ceramic layer on the surface of base separators made of polyolefins such as Polyethylene, Polypropylene and combinations of the two as well as cellulosic base separators. The underlying need for this new technology is the recently identified potential of fire in large format Lithium ion batteries used in hybrid, plug-in hybrid and electric vehicles. The primary potential cause of battery fire is thermal runaway caused by several different electrical or mechanical mechanisms; such as, overcharge, puncture, overheating, compaction, and internal short circuit. During thermal runaway, the ideal separator prevents ion flow and continues to physically separate the anode from the cathode. If the temperature of the battery gets higher, the separator may melt and partially clog the pores and help prevent ion flows but it also can shrink which can result in physical contact of the electrodes and accelerate thermal run-away even further. Ceramic coated separators eliminate many of the problems related to the usage of traditional separators. The ceramic coating provides an electrically insulating layer that retains its physical integrity at high temperature, allows for more efficient thermal heat transfer, helps reduce thermal shrinkage, and inhibits dendrite growth that could create a potential short circuit. The use of Ultraviolet (UV) chemistry to bind fine ceramic particles on separators is a unique and innovative approach primarily because of the instant curing of the UV curable binder upon exposure to UV light. This significant reduction in drying/curing time significantly reduces the

  3. Development and Validation of Web-based Courseware for Junior Secondary School Basic Technology Students in Nigeria

    OpenAIRE

    Anunobi, Anunobi; Njedeka, Vivian; Gambari, Gambari; Isiaka, Amosa; Abdullahi, Abdullahi; Bashiru, Mohammed; Alabi, Alabi; Omotayo, Thomas

    2018-01-01

    This research aimed to develop and validate a web-based courseware for junior secondary school basic technology students in Nigeria. In this study, a mixed method quantitative pilot study design with qualitative components was used to test and ascertain the ease of development and validation of the web-based courseware. Dick and Carey instructional system design model was adopted for developing the courseware. Convenience sampling technique was used in selecting the three content, computer an...

  4. Development and Validation of Web-Based Courseware for Junior Secondary School Basic Technology Students in Nigeria

    OpenAIRE

    Amosa Isiaka Gambari

    2018-01-01

    This research aimed to develop and validate a web-based courseware for junior secondary school basic technology students in Nigeria. In this study, a mixed method quantitative pilot study design with qualitative components was used to test and ascertain the ease of development and validation of the web-based courseware. Dick and Carey instructional system design model was adopted for developing the courseware. Convenience sampling technique was used in selecting the three content, computer an...

  5. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis.

    Science.gov (United States)

    de Vries, R; Brinkman, P; van der Schee, M P; Fens, N; Dijkers, E; Bootsma, S K; de Jongh, F H C; Sterk, P J

    2015-10-15

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We aimed to determine and optimize the technical performance and diagnostic accuracy of exhaled breath analysis linked to routine spirometry. Exhaled breath was collected in triplicate in healthy subjects by an eNose (SpiroNose) based on five identical metal oxide semiconductor sensor arrays (three arrays monitoring exhaled breath and two reference arrays monitoring ambient air) at the rear end of a pneumotachograph. First, the influence of flow, volume, humidity, temperature, environment, etc, was assessed. Secondly, a two-centre case-control study was performed using diagnostic and monitoring visits in day-to-day clinical care in patients with a (differential) diagnosis of asthma, chronic obstructive pulmonary disease (COPD) or lung cancer. Breathprint analysis involved signal processing, environment correction based on alveolar gradients and statistics based on principal component (PC) analysis, followed by discriminant analysis (Matlab2014/SPSS20). Expiratory flow showed a significant linear correlation with raw sensor deflections (R(2)  =  0.84) in 60 healthy subjects (age 43  ±  11 years). No correlation was found between sensor readings and exhaled volume, humidity and temperature. Exhaled data after environment correction were highly reproducible for each sensor array (Cohen's Kappa 0.81-0.94). Thirty-seven asthmatics (41  ±  14.2 years), 31 COPD patients (66  ±  8.4 years), 31 lung cancer patients (63  ±  10.8 years) and 45 healthy controls (41  ±  12.5 years) entered the cross-sectional study. SpiroNose could adequately distinguish between controls, asthma, COPD and lung cancer patients with cross-validation values

  6. Assessing the Validity of Using Serious Game Technology to Analyze Physician Decision Making

    Science.gov (United States)

    Mohan, Deepika; Angus, Derek C.; Ricketts, Daniel; Farris, Coreen; Fischhoff, Baruch; Rosengart, Matthew R.; Yealy, Donald M.; Barnato, Amber E.

    2014-01-01

    Background Physician non-compliance with clinical practice guidelines remains a critical barrier to high quality care. Serious games (using gaming technology for serious purposes) have emerged as a method of studying physician decision making. However, little is known about their validity. Methods We created a serious game and evaluated its construct validity. We used the decision context of trauma triage in the Emergency Department of non-trauma centers, given widely accepted guidelines that recommend the transfer of severely injured patients to trauma centers. We designed cases with the premise that the representativeness heuristic influences triage (i.e. physicians make transfer decisions based on archetypes of severely injured patients rather than guidelines). We randomized a convenience sample of emergency medicine physicians to a control or cognitive load arm, and compared performance (disposition decisions, number of orders entered, time spent per case). We hypothesized that cognitive load would increase the use of heuristics, increasing the transfer of representative cases and decreasing the transfer of non-representative cases. Findings We recruited 209 physicians, of whom 168 (79%) began and 142 (68%) completed the task. Physicians transferred 31% of severely injured patients during the game, consistent with rates of transfer for severely injured patients in practice. They entered the same average number of orders in both arms (control (C): 10.9 [SD 4.8] vs. cognitive load (CL):10.7 [SD 5.6], p = 0.74), despite spending less time per case in the control arm (C: 9.7 [SD 7.1] vs. CL: 11.7 [SD 6.7] minutes, pdecisions consistent with actual practice, that we could manipulate cognitive load, and that load increased the use of heuristics, as predicted by cognitive theory. PMID:25153149

  7. Precision engineering: an evolutionary perspective.

    Science.gov (United States)

    Evans, Chris J

    2012-08-28

    Precision engineering is a relatively new name for a technology with roots going back over a thousand years; those roots span astronomy, metrology, fundamental standards, manufacturing and money-making (literally). Throughout that history, precision engineers have created links across disparate disciplines to generate innovative responses to society's needs and wants. This review combines historical and technological perspectives to illuminate precision engineering's current character and directions. It first provides us a working definition of precision engineering and then reviews the subject's roots. Examples will be given showing the contributions of the technology to society, while simultaneously showing the creative tension between the technological convergence that spurs new directions and the vertical disintegration that optimizes manufacturing economics.

  8. Development of the SEAtrace{trademark} barrier verification and validation technology. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, S.D.; Lowry, W.; Walsh, R.; Rao, D.V. [Science and Engineering Associates, Santa Fe, NM (United States); Williams, C. [Sandia National Labs., Albuquerque, NM (United States). Underground Storage Technology Dept.

    1998-08-01

    In-situ barrier emplacement techniques and materials for the containment of high-risk contaminants in soils are currently being developed by the Department of Energy (DOE). Because of their relatively high cost, the barriers are intended to be used in cases where the risk is too great to remove the contaminants, the contaminants are too difficult to remove with current technologies, or the potential movement of the contaminants to the water table is so high that immediate action needs to be taken to reduce health risks. Assessing the integrity of the barrier once it is emplaced, and during its anticipated life, is a very difficult but necessary requirement. Science and Engineering Associates, Inc., (SEA) and Sandia National Laboratories (SNL) have developed a quantitative subsurface barrier assessment system using gaseous tracers in support of the Subsurface Contaminants Focus Area barrier technology program. Called SEAtrace{trademark}, this system integrates an autonomous, multi-point soil vapor sampling and analysis system with a global optimization modeling methodology to locate and size barrier breaches in real time. The methodology for the global optimization code was completed and a prototype code written using simplifying assumptions. Preliminary modeling work to validate the code assumptions were performed using the T2VOC numerical code. A multi-point field sampling system was built to take soil gas samples and analyze for tracer gas concentration. The tracer concentration histories were used in the global optimization code to locate and size barrier breaches. SEAtrace{trademark} was consistently able to detect and locate leaks, even under very adverse conditions. The system was able to locate the leak to within 0.75 m of the actual value, and was able to determine the size of the leak to within 0.15 m.

  9. Development of the SEAtrace trademark barrier verification and validation technology. Final report

    International Nuclear Information System (INIS)

    Dunn, S.D.; Lowry, W.; Walsh, R.; Rao, D.V.; Williams, C.

    1998-08-01

    In-situ barrier emplacement techniques and materials for the containment of high-risk contaminants in soils are currently being developed by the Department of Energy (DOE). Because of their relatively high cost, the barriers are intended to be used in cases where the risk is too great to remove the contaminants, the contaminants are too difficult to remove with current technologies, or the potential movement of the contaminants to the water table is so high that immediate action needs to be taken to reduce health risks. Assessing the integrity of the barrier once it is emplaced, and during its anticipated life, is a very difficult but necessary requirement. Science and Engineering Associates, Inc., (SEA) and Sandia National Laboratories (SNL) have developed a quantitative subsurface barrier assessment system using gaseous tracers in support of the Subsurface Contaminants Focus Area barrier technology program. Called SEAtrace trademark, this system integrates an autonomous, multi-point soil vapor sampling and analysis system with a global optimization modeling methodology to locate and size barrier breaches in real time. The methodology for the global optimization code was completed and a prototype code written using simplifying assumptions. Preliminary modeling work to validate the code assumptions were performed using the T2VOC numerical code. A multi-point field sampling system was built to take soil gas samples and analyze for tracer gas concentration. The tracer concentration histories were used in the global optimization code to locate and size barrier breaches. SEAtrace trademark was consistently able to detect and locate leaks, even under very adverse conditions. The system was able to locate the leak to within 0.75 m of the actual value, and was able to determine the size of the leak to within 0.15 m

  10. Two Cultures in Modern Science and Technology: For Safety and Validity Does Medicine Have to Update?

    Science.gov (United States)

    Becker, Robert E

    2016-01-11

    Two different scientific cultures go unreconciled in modern medicine. Each culture accepts that scientific knowledge and technologies are vulnerable to and easily invalidated by methods and conditions of acquisition, interpretation, and application. How these vulnerabilities are addressed separates the 2 cultures and potentially explains medicine's difficulties eradicating errors. A traditional culture, dominant in medicine, leaves error control in the hands of individual and group investigators and practitioners. A competing modern scientific culture accepts errors as inevitable, pernicious, and pervasive sources of adverse events throughout medical research and patient care too malignant for individuals or groups to control. Error risks to the validity of scientific knowledge and safety in patient care require systemwide programming able to support a culture in medicine grounded in tested, continually updated, widely promulgated, and uniformly implemented standards of practice for research and patient care. Experiences from successes in other sciences and industries strongly support the need for leadership from the Institute of Medicine's recommended Center for Patient Safely within the Federal Executive branch of government.

  11. Target validation for FCV technology development in Japan from energy competition point of view

    International Nuclear Information System (INIS)

    ENDO Eiichi

    2006-01-01

    The objective of this work is to validate the technical targets in the governmental hydrogen energy road-map of Japan by analyzing market penetration of fuel cell vehicle(FCV)s and effects of fuel price and carbon tax on it from technology competition point of view. In this analysis, an energy system model of Japan based on MARKAL is used. The results of the analysis show that hydrogen FCVs could not have cost-competitiveness until 2030 without carbon tax, including the governmental actual plan of carbon tax. However, as the carbon tax rate increases, instead of conventional vehicles including gasoline hybrid electric vehicle, hydrogen FCVs penetrate to the market earlier and more. By assuming higher fuel price and severer carbon tax rate, market share of hydrogen FCVs approaches to the governmental goal. This suggests that cheaper vehicle cost and/or hydrogen price than those targeted in the road-map is required. At the same time, achievement of the technical targets in the road-map also allows to attain the market penetration target of hydrogen FCVs in some possible conditions. (authors)

  12. Development of the recombinase-based in vivo expression technology in Streptococcus thermophilus and validation using the lactose operon promoter

    NARCIS (Netherlands)

    Junjua, M.; Galia, W.; Gaci, N.; Uriot, O.; Genay, M.; Bachmann, H.; Kleerebezem, M.; Dary, A.; Roussel, Y.

    2014-01-01


    Aims

    To construct and validate the recombinase-based in vivo expression technology (R-IVET) tool in Streptococcus thermophilus (ST).

    Methods and Results

    The R-IVET system we constructed in the LMD-9 strain includes the plasmid pULNcreB allowing transcriptional fusion

  13. Conceptualization of Approaches and Thought Processes Emerging in Validating of Model in Mathematical Modeling in Technology Aided Environment

    Science.gov (United States)

    Hidiroglu, Çaglar Naci; Bukova Güzel, Esra

    2013-01-01

    The aim of the present study is to conceptualize the approaches displayed for validation of model and thought processes provided in mathematical modeling process performed in technology-aided learning environment. The participants of this grounded theory study were nineteen secondary school mathematics student teachers. The data gathered from the…

  14. Validating a Measure of Teacher Intentions to Integrate Technology in Education in Turkey, Spain and the USA

    Science.gov (United States)

    Perkmen, Serkan; Antonenko, Pavlo; Caracuel, Alfonso

    2016-01-01

    The main purpose of this study was to examine the validity of the Teacher Intentions to Integrate Technology in Education Scale using pre-service teacher samples from three countries on three continents--Turkey, Spain and the United States. Study participants were 550 pre-service teachers from three universities in Turkey, Spain and the USA (219,…

  15. Validating the Technology Acceptance Model in the Context of the Laboratory Information System-Electronic Health Record Interface System

    Science.gov (United States)

    Aquino, Cesar A.

    2014-01-01

    This study represents a research validating the efficacy of Davis' Technology Acceptance Model (TAM) by pairing it with the Organizational Change Readiness Theory (OCRT) to develop another extension to the TAM, using the medical Laboratory Information Systems (LIS)--Electronic Health Records (EHR) interface as the medium. The TAM posits that it is…

  16. Design and Validation of Exoskeleton Actuated by Soft Modules toward Neurorehabilitation-Vision-Based Control for Precise Reaching Motion of Upper Limb.

    Science.gov (United States)

    Oguntosin, Victoria W; Mori, Yoshiki; Kim, Hyejong; Nasuto, Slawomir J; Kawamura, Sadao; Hayashi, Yoshikatsu

    2017-01-01

    We demonstrated the design, production, and functional properties of the Exoskeleton Actuated by the Soft Modules (EAsoftM). Integrating the 3D printed exoskeleton with passive joints to compensate gravity and with active joints to rotate the shoulder and elbow joints resulted in ultra-light system that could assist planar reaching motion by using the vision-based control law. The EAsoftM can support the reaching motion with compliance realized by the soft materials and pneumatic actuation. In addition, the vision-based control law has been proposed for the precise control over the target reaching motion within the millimeter scale. Aiming at rehabilitation exercise for individuals, typically soft actuators have been developed for relatively small motions, such as grasping motion, and one of the challenges has been to extend their use for a wider range reaching motion. The proposed EAsoftM presented one possible solution for this challenge by transmitting the torque effectively along the anatomically aligned with a human body exoskeleton. The proposed integrated systems will be an ideal solution for neurorehabilitation where affordable, wearable, and portable systems are required to be customized for individuals with specific motor impairments.

  17. Design and Validation of Exoskeleton Actuated by Soft Modules toward Neurorehabilitation—Vision-Based Control for Precise Reaching Motion of Upper Limb

    Science.gov (United States)

    Oguntosin, Victoria W.; Mori, Yoshiki; Kim, Hyejong; Nasuto, Slawomir J.; Kawamura, Sadao; Hayashi, Yoshikatsu

    2017-01-01

    We demonstrated the design, production, and functional properties of the Exoskeleton Actuated by the Soft Modules (EAsoftM). Integrating the 3D printed exoskeleton with passive joints to compensate gravity and with active joints to rotate the shoulder and elbow joints resulted in ultra-light system that could assist planar reaching motion by using the vision-based control law. The EAsoftM can support the reaching motion with compliance realized by the soft materials and pneumatic actuation. In addition, the vision-based control law has been proposed for the precise control over the target reaching motion within the millimeter scale. Aiming at rehabilitation exercise for individuals, typically soft actuators have been developed for relatively small motions, such as grasping motion, and one of the challenges has been to extend their use for a wider range reaching motion. The proposed EAsoftM presented one possible solution for this challenge by transmitting the torque effectively along the anatomically aligned with a human body exoskeleton. The proposed integrated systems will be an ideal solution for neurorehabilitation where affordable, wearable, and portable systems are required to be customized for individuals with specific motor impairments. PMID:28736514

  18. Design and Validation of Exoskeleton Actuated by Soft Modules toward Neurorehabilitation—Vision-Based Control for Precise Reaching Motion of Upper Limb

    Directory of Open Access Journals (Sweden)

    Victoria W. Oguntosin

    2017-07-01

    Full Text Available We demonstrated the design, production, and functional properties of the Exoskeleton Actuated by the Soft Modules (EAsoftM. Integrating the 3D printed exoskeleton with passive joints to compensate gravity and with active joints to rotate the shoulder and elbow joints resulted in ultra-light system that could assist planar reaching motion by using the vision-based control law. The EAsoftM can support the reaching motion with compliance realized by the soft materials and pneumatic actuation. In addition, the vision-based control law has been proposed for the precise control over the target reaching motion within the millimeter scale. Aiming at rehabilitation exercise for individuals, typically soft actuators have been developed for relatively small motions, such as grasping motion, and one of the challenges has been to extend their use for a wider range reaching motion. The proposed EAsoftM presented one possible solution for this challenge by transmitting the torque effectively along the anatomically aligned with a human body exoskeleton. The proposed integrated systems will be an ideal solution for neurorehabilitation where affordable, wearable, and portable systems are required to be customized for individuals with specific motor impairments.

  19. Advancing Precision Nuclear Medicine and Molecular Imaging for Lymphoma.

    Science.gov (United States)

    Wright, Chadwick L; Maly, Joseph J; Zhang, Jun; Knopp, Michael V

    2017-01-01

    PET with fluorodeoxyglucose F 18 ( 18 F FDG-PET) is a meaningful biomarker for the detection, targeted biopsy, and treatment of lymphoma. This article reviews the evolution of 18 F FDG-PET as a putative biomarker for lymphoma and addresses the current capabilities, challenges, and opportunities to enable precision medicine practices for lymphoma. Precision nuclear medicine is driven by new imaging technologies and methodologies to more accurately detect malignant disease. Although quantitative assessment of response is limited, such technologies will enable a more precise metabolic mapping with much higher definition image detail and thus may make it a robust and valid quantitative response assessment methodology. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Assessing the validity of using serious game technology to analyze physician decision making.

    Science.gov (United States)

    Mohan, Deepika; Angus, Derek C; Ricketts, Daniel; Farris, Coreen; Fischhoff, Baruch; Rosengart, Matthew R; Yealy, Donald M; Barnato, Amber E

    2014-01-01

    Physician non-compliance with clinical practice guidelines remains a critical barrier to high quality care. Serious games (using gaming technology for serious purposes) have emerged as a method of studying physician decision making. However, little is known about their validity. We created a serious game and evaluated its construct validity. We used the decision context of trauma triage in the Emergency Department of non-trauma centers, given widely accepted guidelines that recommend the transfer of severely injured patients to trauma centers. We designed cases with the premise that the representativeness heuristic influences triage (i.e. physicians make transfer decisions based on archetypes of severely injured patients rather than guidelines). We randomized a convenience sample of emergency medicine physicians to a control or cognitive load arm, and compared performance (disposition decisions, number of orders entered, time spent per case). We hypothesized that cognitive load would increase the use of heuristics, increasing the transfer of representative cases and decreasing the transfer of non-representative cases. We recruited 209 physicians, of whom 168 (79%) began and 142 (68%) completed the task. Physicians transferred 31% of severely injured patients during the game, consistent with rates of transfer for severely injured patients in practice. They entered the same average number of orders in both arms (control (C): 10.9 [SD 4.8] vs. cognitive load (CL):10.7 [SD 5.6], p = 0.74), despite spending less time per case in the control arm (C: 9.7 [SD 7.1] vs. CL: 11.7 [SD 6.7] minutes, prepresentative cases in the two arms (C: 45% vs. CL: 34%, p = 0.20), but were more likely to transfer non-representative cases in the control arm (C: 38% vs. CL: 26%, p = 0.03). We found that physicians made decisions consistent with actual practice, that we could manipulate cognitive load, and that load increased the use of heuristics, as predicted by cognitive theory.

  1. Assessing the validity of using serious game technology to analyze physician decision making.

    Directory of Open Access Journals (Sweden)

    Deepika Mohan

    Full Text Available Physician non-compliance with clinical practice guidelines remains a critical barrier to high quality care. Serious games (using gaming technology for serious purposes have emerged as a method of studying physician decision making. However, little is known about their validity.We created a serious game and evaluated its construct validity. We used the decision context of trauma triage in the Emergency Department of non-trauma centers, given widely accepted guidelines that recommend the transfer of severely injured patients to trauma centers. We designed cases with the premise that the representativeness heuristic influences triage (i.e. physicians make transfer decisions based on archetypes of severely injured patients rather than guidelines. We randomized a convenience sample of emergency medicine physicians to a control or cognitive load arm, and compared performance (disposition decisions, number of orders entered, time spent per case. We hypothesized that cognitive load would increase the use of heuristics, increasing the transfer of representative cases and decreasing the transfer of non-representative cases.We recruited 209 physicians, of whom 168 (79% began and 142 (68% completed the task. Physicians transferred 31% of severely injured patients during the game, consistent with rates of transfer for severely injured patients in practice. They entered the same average number of orders in both arms (control (C: 10.9 [SD 4.8] vs. cognitive load (CL:10.7 [SD 5.6], p = 0.74, despite spending less time per case in the control arm (C: 9.7 [SD 7.1] vs. CL: 11.7 [SD 6.7] minutes, p<0.01. Physicians were equally likely to transfer representative cases in the two arms (C: 45% vs. CL: 34%, p = 0.20, but were more likely to transfer non-representative cases in the control arm (C: 38% vs. CL: 26%, p = 0.03.We found that physicians made decisions consistent with actual practice, that we could manipulate cognitive load, and that load increased

  2. Validation of Align Technology's Treat III digital model superimposition tool and its case application.

    Science.gov (United States)

    Miller, R J; Kuo, E; Choi, W

    2003-01-01

    An assessment of the efficacy and accuracy of three-dimensional computer-based predictive orthodontic systems requires that new methods of treatment analysis be developed and validated. Invisalign is a digitally fabricated, removable orthodontic appliance that has been commercially available since 1999. It is made up of two main components: 1) computerized graphical images of a patient's teeth moving through a series of stages from initial to final position; 2) pressure formed clear plastic appliances made from stereolithography models of the images in the first component. The manufacturer of Invisalign (Align Technology, Inc.) has created a software tool that can be used to superimpose digital models to evaluate treatment outcomes in three dimensions. Using this software, research was conducted to determine if a single operator could repeatedly superimpose two identical digital models using 12 selected points from the palatal rugae over 10 trials. The tool was then applied to one subject's orthodontic treatment. EXPERIMENT VARIABLES: The output from this tool includes rotations, translations and morphological changes. For this study, translations and rotations were chosen. The results showed that the digital superimposition was reproducible, and that after multiple trials, the superimposition error decreased. The average error in x, y, z, Rx, Ry and Rz after 10 trials was determined to approach approximately 0.2 mm in translation and less than 1 degree in rotation, with a standard deviation of 0.15 mm and 0.7 mm, respectively. The treatment outcome from a single Invisalign-treated bicuspid extraction case was also evaluated tooth-by-tooth in x, y, z, Rx, Ry and Rz dimensions. Using the palate, as a stable reference seemed to work well and the evaluation of the single case showed that many, but not all, of the planned movements occurred.

  3. Validation test of advanced technology for IPV nickel-hydrogen flight cells - Update

    Science.gov (United States)

    Smithrick, John J.; Hall, Stephen W.

    1992-01-01

    Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the LEO cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion.

  4. Long Term Validation of High Precision RTK Positioning Onboard a Ferry Vessel Using the MGBAS in the Research Port of Rostock

    Directory of Open Access Journals (Sweden)

    Ralf Ziebold

    2017-09-01

    Full Text Available In order to enable port operations, which require an accuracy of about 10cm, the German Aerospace Center (DLR operates the Maritime Ground Based Augmentation Service (MGBAS in the Research Port of Rostock. The MGBAS reference station provides GPS dual frequency code + phase correction data, which are continuously transmitted via an ultra-high frequency (UHF modem. Up to now the validation of the MGBAS was rather limited. Either a second shore based station was used as an artificial user, or measurement campaigns on a vessel with duration of a few hours have been conducted. In order to overcome this, we have installed three separate dual frequency antennas and receivers and a UHF modem on the Stena Line ferry vessel Mecklenburg-Vorpommern which is plying between Rostock and Trelleborg. This paper concentrates on the analysis of the highly accurate phase based positioning with a Real Time Kinematic (RTK algorithm, using correction data received by the UHF modem onboard the vessel. We analyzed the availability and accuracy of RTK fix solutions for several days, whenever the ferry vessel was inside the service area of the MGBAS.

  5. The development of advanced instrumentation and control technology -The development of verification and validation technology for instrumentation and control in NPPs-

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Ham, Chang Sik; Lee, Byung Sun; Kim, Jung Taek; Park, Won Man; Park, Jae Chang; Lee, Jang Soo; Um, Heung Sub; Kim, Jang Yul; Ryoo, Chan Hoh; Joo, Jae Yoon; Song, Soon Ja

    1995-07-01

    We collected and analyzed the domestic/international codes, standards and guidelines to develop high reliable software verification and validation methodology which is satisfied to our real situation. The three major parts of work are performed that is the construction of the frame for high reliable software development environment, establishment of high reliable software development methodology and study for the basic technology related to safety-critical software. These three parts are tightly coupled each other to achieve self-reliable software verification and validation technology for digital I and C in NPPs. The configuration of hardware and software are partly performed using requirements which is developed in first stage for the development of I and C test facility. In hardware part, expanded interface using VXI bus and driving software is completed. The main program for math, modelling and supervisor program for instructions are developed. 27 figs, 22 tabs, 69 refs. (Author)

  6. The development of advanced instrumentation and control technology -The development of verification and validation technology for instrumentation and control in NPPs-

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Ham, Chang Sik; Lee, Byung Sun; Kim, Jung Taek; Park, Won Man; Park, Jae Chang; Lee, Jang Soo; Um, Heung Sub; Kim, Jang Yul; Ryoo, Chan Hoh; Joo, Jae Yoon; Song, Soon Ja [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    We collected and analyzed the domestic/international codes, standards and guidelines to develop high reliable software verification and validation methodology which is satisfied to our real situation. The three major parts of work are performed that is the construction of the frame for high reliable software development environment, establishment of high reliable software development methodology and study for the basic technology related to safety-critical software. These three parts are tightly coupled each other to achieve self-reliable software verification and validation technology for digital I and C in NPPs. The configuration of hardware and software are partly performed using requirements which is developed in first stage for the development of I and C test facility. In hardware part, expanded interface using VXI bus and driving software is completed. The main program for math, modelling and supervisor program for instructions are developed. 27 figs, 22 tabs, 69 refs. (Author).

  7. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis

    NARCIS (Netherlands)

    de Vries, R.; Brinkman, P.; van der Schee, M. P.; Fens, N.; Dijkers, E.; Bootsma, S. K.; de Jongh, F. H. C.; Sterk, P. J.

    2015-01-01

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We

  8. Education Technology Standards Self-Efficacy (ETSSE) Scale: A Validity and Reliability Study

    Science.gov (United States)

    Simsek, Omer; Yazar, Taha

    2016-01-01

    Problem Statement: The educational technology standards for teachers set by the International Society for Technology in Education (the ISTE Standards-T) represent an important framework for using technology effectively in teaching and learning processes. These standards are widely used by universities, educational institutions, and schools. The…

  9. Achievement Emotions in Technology Enhanced Learning: Development and Validation of Self-Report Instruments in the Italian Context

    Directory of Open Access Journals (Sweden)

    Daniela Raccanello

    2015-02-01

    Full Text Available The increased use of technology within the educational field gives rise to the need for developing valid instruments to measure key constructs associated with performance. We present some self-report instruments developed and/or validated in the Italian context that could be used to assess achievement emotions and correlates, within the theoretical framework of Pekrun’s control-value model. First, we propose some data related to the construction of two instruments developed to assess ten achievement emotions: the Brief Achievement Emotions Questionnaire, BR-AEQ, used with college students, and the Graduated Achievement Emotions Set, GR-AES, used with primary school students. Second, we describe some data concerning the validation within the Italian context of two instruments assessing achievement goals as antecedents of achievement emotions: the Achievement Goal Questionnaire-Revised, AGQ-R, and its more recent version based on the 3 X 2 achievement goal model.

  10. Research and development of a technology to create original high-function materials in fiscal 1998 (development of precision structure controlling materials by improving petroleum refining). Report on achievements in research and development of precision catalytic polymerization; 1998 nendo dokusoteki kokino zairyo sosei gijutsu no kenkyu kaihatsu seika hokokusho. Sekiyu seisei kodoka seimitsu kozo seigyo zairyo kaihatsu (seimitsu shokubai jugo no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Research and development on precision catalytic polymerization aims at developing polymerizing catalysts that can control arbitrarily the molecular weight and three-dimensional regularity by which rapid enhancement can be expected in performance of additional polymerization type polymers, and the primary structure of terminal groups. Works are being done on two sub-themes of ultimate additional polymerization and orientation catalyst polymerization. The research and development of the ultimate additional polymerization included structural control in polymerization reaction in vinyl chloride, vinylester and acrylic monomers, radical polymerization with precision orientation control, anionic polymerization with precision structural control, and precision polymerization utilizing asymmetric metal porphyrin complexes. In the research and development of the orientation catalyst polymerization, the orientation catalyst polymerization was researched and developed, elementary reaction of metallocene was elucidated, high-performance carrier catalysts were developed, advanced function polymers were synthesized at high precision based on metathesis, and improvement of functions of polyolefin was researched and developed. Surveys and studies were carried out on fundamental technologies common to the above two themes re-commissioned to five universities. (NEDO)

  11. Validity of Business Strategy as Driver in Technology Management – A Critical Discussion

    DEFF Research Database (Denmark)

    Tambo, Torben; Østergaard, Klaus

    2015-01-01

    in connecting technological design tightly to the business strategy. The purpose of this paper is to advance a research agenda, where long-term orientation of technology is connected to the necessary tools for obtaining insight in assessing adequacy, reliability and quality of business strategy and evaluation......Frameworks for technological development are increasingly requiring that technology must be developed in accordance with the corporate business strategy. It is an interesting tendency that technological development should reflect and interact with central change processes of the enterprise...... of alternatives. Alternatives are related to business environments, compliance, infrastructure, knowledge, skills and societal factors....

  12. [Translation and validation of the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0) into Portuguese].

    Science.gov (United States)

    de Carvalho, Karla Emanuelle Cotias; Gois Júnior, Miburge Bolívar; Sá, Katia Nunes

    2014-01-01

    To translate and validate the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0) into Brazilian Portuguese. Certified translators translated and back-translated Quest. Content validity (CVI) was determined by 5 experts and, after the final version of B-Quest, a pre-test was applied to users of manual wheelchairs, walkers and crutches. The psychometric properties were tested to assure the validity of items and the reliability and stability of the scale. Data were obtained from 121 users of the above-mentioned devices. Our study showed a CVI of 91.66% and a satisfactory factor analysis referent to the two-dimensional structure of the instrument that ensured the representativeness of the items. The Cron-bach's alpha of the items device, service and total score of B-Quest were 0.862, 0.717 and 0.826, respectively. Test-retest stability conducted after a time interval of 2 months was analyzed using Spearman's correlation test, which showed high correlation (ρ >0.6) for most items. The study suggests that the B-Quest is a reliable, representative, and valid instrument to measure the satisfaction of users of assistive technology in Brazil. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  13. Blockchain Technology: A Data Framework to Improve Validity, Trust, and Accountability of Information Exchange in Health Professions Education.

    Science.gov (United States)

    Funk, Eric; Riddell, Jeff; Ankel, Felix; Cabrera, Daniel

    2018-06-12

    Health professions educators face multiple challenges, among them the need to adapt educational methods to new technologies. In the last decades multiple new digital platforms have appeared in the learning arena, including massive open online courses and social media-based education. The major critique of these novel methods is the lack of the ability to ascertain the origin, validity, and accountability of the knowledge that is created, shared, and acquired. Recently, a novel technology based on secured data storage and transmission, called blockchain, has emerged as a way to generate networks where validity, trust, and accountability can be created. Conceptually blockchain is an open, public, distributed, and secure digital registry where information transactions are secured and have a clear origin, explicit pathways, and concrete value. Health professions education based on the blockchain will potentially allow improved tracking of content and the individuals who create it, quantify educational impact on multiple generations of learners, and build a relative value of educational interventions. Furthermore, institutions adopting blockchain technology would be able to provide certification and credentialing of healthcare professionals with no intermediaries. There is potential for blockchain to significantly change the future of health professions education and radically transform how patients, professionals, educators, and learners interact around safe, valid, and accountable information.

  14. Towards Developing an Industry-Validated Food Technology Curriculum in Afghanistan

    Science.gov (United States)

    Ebner, Paul; McNamara, Kevin; Deering, Amanda; Oliver, Haley; Rahimi, Mirwais; Faisal, Hamid

    2017-01-01

    Afghanistan remains an agrarian country with most analyses holding food production and processing as key to recovery. To date, however, there are no public or private higher education departments focused on food technology. To bridge this gap, Herat University initiated a new academic department conferring BS degrees in food technology. Models for…

  15. Technological Pedagogical Content Knowledge (TPACK): The Development and Validation of an Assessment Instrument for Preservice Teachers

    Science.gov (United States)

    Schmidt, Denise A.; Baran, Evrim; Thompson, Ann D.; Mishra, Punya; Koehler, Matthew J.; Shin, Tae S.

    2009-01-01

    Based in Shulman's idea of Pedagogical Content Knowledge, Technological Pedagogical Content Knowledge (TPACK) has emerged as a useful frame for describing and understanding the goals for technology use in preservice teacher education. This paper addresses the need for a survey instrument designed to assess TPACK for preservice teachers. The paper…

  16. Global Positioning System Technology (GPS for Psychological Research: A Test of Convergent and Nomological Validity

    Directory of Open Access Journals (Sweden)

    Pedro eWolf

    2013-06-01

    Full Text Available The purpose of this paper is to examine the convergent and nomological validity of a GPS-based measure of daily activity, operationalized as Number of Places Visited (NPV. Relations among the GPS-based measure and two self-report measures of NPV, as well as relations among NPV and two factors made up of self-reported individual differences were examined. The first factor was composed of variables related to an Active Lifestyle (AL (e.g. positive affect, extraversion… and the second factor was composed of variables related to a Sedentary Lifestyle (SL (e.g. depression, neuroticism…. NPV was measured over a four-day period. This timeframe was made up of two week and two weekend days. A bi-variate analysis established one level of convergent validity and a Split-Plot GLM examined convergent validity, nomological validity, and alternative hypotheses related to constraints on activity throughout the week simultaneously. The first analysis revealed significant correlations among NPV measures- weekday, weekend, and the entire four day blocks, supporting the convergent validity of the Diary-, Google Maps-, and GPS-NPV measures. Results from the second analysis, indicating non-significant mean differences in NPV regardless of method, also support this conclusion. We also found that AL is a statistically significant predictor of NPV no matter how NPV was measured. We did not find a statically significant relation among NPV and SL. These results permit us to infer that the GPS-based NPV measure has convergent and nomological validity.

  17. Technology: cancer treatment: breath control set radiotherapy free. Two new methods allow to aim the tumors with precision without suffering of respiratory move

    International Nuclear Information System (INIS)

    Blanc, S.

    2004-01-01

    The challenge of radiotherapy consists in improving the ratio between the destruction of tumor cells and the preservation of sane cells. The efficiency of the treatment depends on the precision of radiations impact on the tumor but this one is difficult to get because the patient respiration makes the target mobile. It is now possible to get this precision. It is a question to block the patient respiration or to register the movements and then establish the shooting window of radiations in function of the tumor optimum exposure. (N.C.)

  18. Fostering creativity in product and service development: validation in the domain of information technology.

    Science.gov (United States)

    Zeng, Liang; Proctor, Robert W; Salvendy, Gavriel

    2011-06-01

    This research is intended to empirically validate a general model of creative product and service development proposed in the literature. A current research gap inspired construction of a conceptual model to capture fundamental phases and pertinent facilitating metacognitive strategies in the creative design process. The model also depicts the mechanism by which design creativity affects consumer behavior. The validity and assets of this model have not yet been investigated. Four laboratory studies were conducted to demonstrate the value of the proposed cognitive phases and associated metacognitive strategies in the conceptual model. Realistic product and service design problems were used in creativity assessment to ensure ecological validity. Design creativity was enhanced by explicit problem analysis, whereby one formulates problems from different perspectives and at different levels of abstraction. Remote association in conceptual combination spawned more design creativity than did near association. Abstraction led to greater creativity in conducting conceptual expansion than did specificity, which induced mental fixation. Domain-specific knowledge and experience enhanced design creativity, indicating that design can be of a domain-specific nature. Design creativity added integrated value to products and services and positively influenced customer behavior. The validity and value of the proposed conceptual model is supported by empirical findings. The conceptual model of creative design could underpin future theory development. Propositions advanced in this article should provide insights and approaches to facilitate organizations pursuing product and service creativity to gain competitive advantage.

  19. The feasibility and concurrent validity of performing the Movement Assessment Battery for Children - 2nd Edition via telerehabilitation technology.

    Science.gov (United States)

    Nicola, Kristy; Waugh, Jemimah; Charles, Emily; Russell, Trevor

    2018-06-01

    In rural and remote communities children with motor difficulties have less access to rehabilitation services. Telerehabilitation technology is a potential method to overcome barriers restricting access to healthcare in these areas. Assessment is necessary to guide clinical reasoning; however it is unclear which paediatric assessments can be administered remotely. The Movement Assessment Battery for Children - 2nd Edition is commonly used by various health professionals to assess motor performance of children. The aim of this study was to investigate the feasibility and concurrent validity of performing the Movement Assessment Battery for Children - 2nd Edition remotely via telerehabilitation technology compared to the conventional in-person method. Fifty-nine children enrolled in a state school (5-11 years old) volunteered to perform one in-person and one telerehabilitation mediated assessment. The order of the method of delivery and the therapist performing the assessment were randomized. After both assessments were complete, a participant satisfaction questionnaire was completed by each child. The Bland-Altman limits of agreement for the total test standard score were -3.15 to 3.22 which is smaller than a pre-determined clinically acceptable margin based on the smallest detectable change. This study establishes the feasibility and concurrent validity of the administration of the Movement Assessment Battery for Children - 2nd Edition via telerehabilitation technology. Overall, participants perceived their experience with telerehabilitation positively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Combining novel monitoring tools and precision application technologies for integrated high-tech crop protection in the future (a discussion document)

    NARCIS (Netherlands)

    Zijlstra, C.; Lund, I.; Justesen, A.; Nicolaisen, M.; Bianciotto, V.; Posta, K.; Balestrini, R.; Przetakiewicz, A.; Czembor, E.; Zande, van de J.

    2011-01-01

    The possibility of combining novel monitoring techniques and precision spraying for crop protection in the future is discussed. A generic model for an innovative crop protection system has been used as a framework. This system will be able to monitor the entire cropping system and identify the

  1. Rhodopsin in plasma from patients with diabetic retinopathy - development and validation of digital ELISA by Single Molecule Array (Simoa) technology

    DEFF Research Database (Denmark)

    Petersen, Eva Rabing Brix; Olsen, Dorte Aalund; Christensen, Henry

    2017-01-01

    BACKGROUND: Diabetic retinopathy (DR) is the most frequent cause of blindness among younger adults in the western world. No blood biomarkers exist to detect DR. Hypothetically, Rhodopsin concentrations in blood has been suggested as an early marker for retinal damage. The aim of this study...... was therefore to develop and validate a Rhodopsin assay by employing digital ELISA technology, and to investigate whether Rhodopsin concentrations in diabetes patients with DR are elevated compared with diabetes patients without DR. METHODS: A digital ELISA assay using a Simoa HD-1 Analyzer (Quanterix......©, Lexington, MA 02421, USA) was developed and validated and applied on a cohort of diabetes patients characterised with (n=466) and without (n=144) DR. RESULTS: The Rhodopsin assay demonstrated a LOD of 0.26ng/l, a LLOQ of 3ng/l and a linear measuring range from 3 to 2500ng/l. Total CV% was 32%, 23%, 19...

  2. Utilization of a Text and Translation Application for Communication With a Foreign Deaf Family: A Call for Validation of This Technology-A Case Report.

    Science.gov (United States)

    Fernandez, Patrick G; Brockel, Megan A; Lipscomb, Lisa L; Ing, Richard J; Tailounie, Muayyad

    2017-07-15

    Effective communication with patients is essential to quality care. Obviously, language barriers significantly impact this and can increase the risk of poor patient outcomes. Smartphones and mobile health technology are valuable resources that are beginning to break down language barriers in health care. We present a case of a challenging language barrier where successful perioperative communication was achieved using mobile technology. Although quite beneficial, use of technology that is not validated exposes providers to unnecessary medicolegal risk. We hope to highlight the need for validation of such technology to ensure that these tools are an effective way to accurately communicate with patients in the perioperative setting.

  3. Development and Validation of an Inflammatory Bowel Diseases Monitoring Index for Use With Mobile Health Technologies

    NARCIS (Netherlands)

    van Deen, Welmoed K.; van der Meulen-de Jong, Andrea E.; Parekh, Nimisha K.; Kane, Ellen; Zand, Aria; DiNicola, Courtney A.; Hall, Laurin; Inserra, Elizabeth K.; Choi, Jennifer M.; Ha, Christina Y.; Esrailian, Eric; van Oijen, Martijn G. H.; Hommes, Daniel W.

    2016-01-01

    Mobile health technologies are advancing rapidly as smartphone use increases. Patients with inflammatory bowel disease (IBD) might be managed remotely through smartphone applications, but no tools are yet available. We tested the ability of an IBD monitoring tool, which can be used with mobile

  4. 78 FR 23472 - Amendments to Existing Validated End-User Authorizations: CSMC Technologies Corporation in the...

    Science.gov (United States)

    2013-04-19

    ... Corporation in the People's Republic of China (PRC) AGENCY: Bureau of Industry and Security, Commerce. ACTION... Technologies Corporation (CSMC) in the People's Republic of China (PRC). Specifically, BIS amends Supplement No... comment are not required under the APA or by any other law, the analytical requirements of the Regulatory...

  5. Information-Processing Architectures in Multidimensional Classification: A Validation Test of the Systems Factorial Technology

    Science.gov (United States)

    Fific, Mario; Nosofsky, Robert M.; Townsend, James T.

    2008-01-01

    A growing methodology, known as the systems factorial technology (SFT), is being developed to diagnose the types of information-processing architectures (serial, parallel, or coactive) and stopping rules (exhaustive or self-terminating) that operate in tasks of multidimensional perception. Whereas most previous applications of SFT have been in…

  6. A new application and experimental validation of moulding technology for ferrite magnet assisted synchronous reluctance machine

    DEFF Research Database (Denmark)

    Wu, Qian; Lu, Kaiyuan; Rasmussen, Peter Omand

    2016-01-01

    This paper introduces a new application of moulding technology to the installation of ferrite magnet material into the rotor flux barriers of Ferrite Magnet Assisted Synchronous Reluctance Machine (FASynRM). The feasibility of this application with respect to manufacturing process and motor...

  7. Validation of tissue microarray technology in squamous cell carcinoma of the esophagus

    NARCIS (Netherlands)

    Boone, Judith; van Hillegersberg, Richard; van Diest, Paul J.; Offerhaus, G. Johan A.; Borel Rinkes, Inne H. M.; ten Kate, Fiebo J. W.

    2008-01-01

    Tissue microarray (TMA) technology has been developed to facilitate high-throughput immunohistochemical and in situ hybridization analysis of tissues by inserting small tissue biopsy cores into a single paraffin block. Several studies have revealed novel prognostic biomarkers in esophageal squamous

  8. Fundamentals of precision medicine

    Science.gov (United States)

    Divaris, Kimon

    2018-01-01

    Imagine a world where clinicians make accurate diagnoses and provide targeted therapies to their patients according to well-defined, biologically-informed disease subtypes, accounting for individual differences in genetic make-up, behaviors, cultures, lifestyles and the environment. This is not as utopic as it may seem. Relatively recent advances in science and technology have led to an explosion of new information on what underlies health and what constitutes disease. These novel insights emanate from studies of the human genome and microbiome, their associated transcriptomes, proteomes and metabolomes, as well as epigenomics and exposomics—such ‘omics data can now be generated at unprecedented depth and scale, and at rapidly decreasing cost. Making sense and integrating these fundamental information domains to transform health care and improve health remains a challenge—an ambitious, laudable and high-yield goal. Precision dentistry is no longer a distant vision; it is becoming part of the rapidly evolving present. Insights from studies of the human genome and microbiome, their associated transcriptomes, proteomes and metabolomes, and epigenomics and exposomics have reached an unprecedented depth and scale. Much more needs to be done, however, for the realization of precision medicine in the oral health domain. PMID:29227115

  9. Validation of smart sensor technologies for instrument calibration reduction in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Mitchell, D.W.; Petersen, K.M.; Shell, C.S.

    1993-01-01

    This report presents the preliminary results of a research and development project on the validation of new techniques for on-line testing of calibration drift of process instrumentation channels in nuclear power plants. These techniques generally involve a computer-based data acquisition and data analysis system to trend the output of a large number of instrument channels and identify the channels that have drifted out of tolerance. This helps limit the calibration effort to those channels which need the calibration, as opposed to the current nuclear industry practice of calibrating essentially all the safety-related instrument channels at every refueling outage

  10. Development and validation of a septoplasty training model using 3-dimensional printing technology.

    Science.gov (United States)

    AlReefi, Mahmoud A; Nguyen, Lily H P; Mongeau, Luc G; Haq, Bassam Ul; Boyanapalli, Siddharth; Hafeez, Nauman; Cegarra-Escolano, Francois; Tewfik, Marc A

    2017-04-01

    Providing alternative training modalities may improve trainees' ability to perform septoplasty. Three-dimensional printing has been shown to be a powerful tool in surgical training. The objectives of this study were to explain the development of our 3-dimensional (3D) printed septoplasty training model, to assess its face and content validity, and to present evidence supporting its ability to distinguish between levels of surgical proficiency. Imaging data of a patient with a nasal septal deviation was selected for printing. Printing materials reproducing the mechanical properties of human tissues were selected based on literature review and prototype testing. Eight expert rhinologists, 6 senior residents, and 6 junior residents performed endoscopic septoplasties on the model and completed a postsimulation survey. Performance metrics in quality (final product analysis), efficiency (time), and safety (eg, perforation length, nares damage) were recorded and analyzed in a study-blind manner. The model was judged to be anatomically correct and the steps performed realistic, with scores of 4.05 ± 0.82 and 4.2 ± 1, respectively, on a 5-point Likert scale. Ninety-two percent of residents desired the simulator to be integrated into their teaching curriculum. There was a significant difference (p simulator training models for septoplasty. Our model incorporates 2 different materials mixed into the 3 relevant consistencies necessary to simulate septoplasty. Our findings provide evidence supporting the validity of the model. © 2016 ARS-AAOA, LLC.

  11. Low Cost Precision Lander for Lunar Exploration

    Science.gov (United States)

    Head, J. N.; Gardner, T. G.; Hoppa, G. V.; Seybold, K. G.

    2004-12-01

    ) provide data for the terminal guidance algorithms. DSMAC acquires high-resolution images for real-time correlation with a reference map. This system provides ownship position with a resolution comparable to the map. Since the DSMAC can sample at 1.5 mrad, any imaging acquired below 70 km altitude will surpass the resolution available from previous missions. DSMAC has a mode where image data are compressed and downlinked. This capability could be used to downlink live images during terminal guidance. Approximately 500 kbitps telemetry would be required to provide the first live descent imaging sequence since Ranger. This would provide unique geologic context imaging for the landing site. The development path to produce such a vehicle is that used to develop missiles. First, a pathfinder vehicle is designed and built as a test bed for hardware integration including science instruments. Second, a hover test vehicle would be built. Equipped with mass mockups for the science payload, the vehicle would otherwise be an exact copy of the flight vehicle. The hover vehicle would be flown on earth to demonstrate the proper function and integration of the propulsion system, autopilots, navigation algorithms, and guidance sensors. There is sufficient delta-v in the proposed design to take off from the ground, fly a ballistic arc to over 100 m altitude, then guide to a precision soft landing. Once the vehicle has flown safely on earth, then the validated design would be used to produce the flight vehicle. Since this leverages the billions of dollars DOD has invested in these technologies, it should be possible to land useful science payloads precisely on the lunar surface at relatively low cost.

  12. An Assessment of Imaging Informatics for Precision Medicine in Cancer.

    Science.gov (United States)

    Chennubhotla, C; Clarke, L P; Fedorov, A; Foran, D; Harris, G; Helton, E; Nordstrom, R; Prior, F; Rubin, D; Saltz, J H; Shalley, E; Sharma, A

    2017-08-01

    Objectives: Precision medicine requires the measurement, quantification, and cataloging of medical characteristics to identify the most effective medical intervention. However, the amount of available data exceeds our current capacity to extract meaningful information. We examine the informatics needs to achieve precision medicine from the perspective of quantitative imaging and oncology. Methods: The National Cancer Institute (NCI) organized several workshops on the topic of medical imaging and precision medicine. The observations and recommendations are summarized herein. Results: Recommendations include: use of standards in data collection and clinical correlates to promote interoperability; data sharing and validation of imaging tools; clinician's feedback in all phases of research and development; use of open-source architecture to encourage reproducibility and reusability; use of challenges which simulate real-world situations to incentivize innovation; partnership with industry to facilitate commercialization; and education in academic communities regarding the challenges involved with translation of technology from the research domain to clinical utility and the benefits of doing so. Conclusions: This article provides a survey of the role and priorities for imaging informatics to help advance quantitative imaging in the era of precision medicine. While these recommendations were drawn from oncology, they are relevant and applicable to other clinical domains where imaging aids precision medicine. Georg Thieme Verlag KG Stuttgart.

  13. FROM PERSONALIZED TO PRECISION MEDICINE

    Directory of Open Access Journals (Sweden)

    K. V. Raskina

    2017-01-01

    Full Text Available The need to maintain a high quality of life against a backdrop of its inevitably increasing duration is one of the main problems of modern health care. The concept of "right drug to the right patient at the right time", which at first was bearing the name "personalized", is currently unanimously approved by international scientific community as "precision medicine". Precision medicine takes all the individual characteristics into account: genes diversity, environment, lifestyles, and even bacterial microflora and also involves the use of the latest technological developments, which serves to ensure that each patient gets assistance fitting his state best. In the United States, Canada and France national precision medicine programs have already been submitted and implemented. The aim of this review is to describe the dynamic integration of precision medicine methods into routine medical practice and life of modern society. The new paradigm prospects description are complemented by figures, proving the already achieved success in the application of precise methods for example, the targeted therapy of cancer. All in all, the presence of real-life examples, proving the regularity of transition to a new paradigm, and a wide range  of technical and diagnostic capabilities available and constantly evolving make the all-round transition to precision medicine almost inevitable.

  14. Prompt and Precise Prototyping

    Science.gov (United States)

    2003-01-01

    For Sanders Design International, Inc., of Wilton, New Hampshire, every passing second between the concept and realization of a product is essential to succeed in the rapid prototyping industry where amongst heavy competition, faster time-to-market means more business. To separate itself from its rivals, Sanders Design aligned with NASA's Marshall Space Flight Center to develop what it considers to be the most accurate rapid prototyping machine for fabrication of extremely precise tooling prototypes. The company's Rapid ToolMaker System has revolutionized production of high quality, small-to-medium sized prototype patterns and tooling molds with an exactness that surpasses that of computer numerically-controlled (CNC) machining devices. Created with funding and support from Marshall under a Small Business Innovation Research (SBIR) contract, the Rapid ToolMaker is a dual-use technology with applications in both commercial and military aerospace fields. The advanced technology provides cost savings in the design and manufacturing of automotive, electronic, and medical parts, as well as in other areas of consumer interest, such as jewelry and toys. For aerospace applications, the Rapid ToolMaker enables fabrication of high-quality turbine and compressor blades for jet engines on unmanned air vehicles, aircraft, and missiles.

  15. Rocket-Based Combined Cycle Engine Technology Development: Inlet CFD Validation and Application

    Science.gov (United States)

    DeBonis, J. R.; Yungster, S.

    1996-01-01

    A CFD methodology has been developed for inlet analyses of Rocket-Based Combined Cycle (RBCC) Engines. A full Navier-Stokes analysis code, NPARC, was used in conjunction with pre- and post-processing tools to obtain a complete description of the flow field and integrated inlet performance. This methodology was developed and validated using results from a subscale test of the inlet to a RBCC 'Strut-Jet' engine performed in the NASA Lewis 1 x 1 ft. supersonic wind tunnel. Results obtained from this study include analyses at flight Mach numbers of 5 and 6 for super-critical operating conditions. These results showed excellent agreement with experimental data. The analysis tools were also used to obtain pre-test performance and operability predictions for the RBCC demonstrator engine planned for testing in the NASA Lewis Hypersonic Test Facility. This analysis calculated the baseline fuel-off internal force of the engine which is needed to determine the net thrust with fuel on.

  16. Point-of-care solution for osteoporosis management design, fabrication, and validation of new technology

    CERN Document Server

    Khashayar, Patricia

    2017-01-01

    This book addresses the important clinical problem of accurately diagnosing osteoporosis, and analyzes how Bone Turnover Markers (BTMs) can improve osteoporosis detection. In her research, the author integrated microfluidic technology with electrochemical sensing to embody a reaction/detection chamber to measure serum levels of different biomarkers, creating a microfluidic proteomic platform that can easily be translated into a biomarker diagnostic. The Osteokit System, a result of the integration of electrochemical system and microfluidic chips, is a unique design that offers the potential for greater sensitivity. The implementation, feasibility, and specificity of the Osteokit platform is demonstrated in this book, which is appropriate for researchers working on bone biology and mechanics, as well as clinicians.

  17. Validity of VR Technology on the Smartphone for the Study of Wind Park Soundscapes

    Directory of Open Access Journals (Sweden)

    Tianhong YU

    2018-04-01

    Full Text Available The virtual reality of the landscape environment supplies a high level of realism of the real environment, and may improve the public awareness and acceptance of wind park projects. The soundscape around wind parks could have a strong influence on the acceptance and annoyance of wind parks. To explore this VR technology on realism and subjective responses toward different soundscapes of ambient wind parks, three different types of virtual reality on the smartphone tests were performed: aural only, visual only, and aural–visual combined. In total, 21 aural and visual combinations were presented to 40 participants. The aural and visual information used were of near wind park settings and rural spaces. Perceived annoyance levels and realism of the wind park environment were measured. Results indicated that most simulations were rated with relatively strong realism. Perceived realism was strongly correlated with light, color, and vegetation of the simulation. Most wind park landscapes were enthusiastically accepted by the participants. The addition of aural information was found to have a strong impact on whether the participant was annoyed. Furthermore, evaluation of the soundscape on a multidimensional scale revealed the key components influencing the individual’s annoyance by wind parks were the factors of “calmness/relaxation” and “naturality/pleasantness”. “Diversity” of the soundscape might correlate with perceived realism. Finally, the dynamic aural–visual stimuli using virtual reality technology could improve the environmental assessment of the wind park landscapes, and thus, provide a more comprehensible scientific decision than conventional tools. In addition, this study could improve the participatory planning process for more acceptable wind park landscapes.

  18. Nutritional, technological and managerial parameters for precision feeding to enhance feed nutrient utilization and productivity in different dairy cattle production systems

    DEFF Research Database (Denmark)

    van Empel, Mireille JM; Makkar, Harinder PS; Dijkstra, Jan

    2016-01-01

    Increased future demand of animal products as well as competition between food, feed and fuel, require efficient utilization of feed resources to strengthen environmental, economic and social sustainability of livestock systems. The objective of this review is to summarize current knowledge...... on precision feeding (PF) and the relevance of PF approaches in dairy cattle production systems in developing countries. The concept of PF aims at achieving balanced nutrition (matching animal requirements with nutrient supply, preferably from locally available feed resources) to improve animal productivity...... and to reduce both the cost of production and environmental pollution. In addition to the supply of proper amounts of nutrients to the dairy cow using various methodologies and tools, approaches that enhance overall nutrient digestion and availability to the animal are also discussed as an integral part of PF...

  19. Validation of an explanatory tool for data-fused displays for high-technology future aircraft

    Science.gov (United States)

    Fletcher, Georgina C. L.; Shanks, Craig R.; Selcon, Stephen J.

    1996-05-01

    As the number of sensor and data sources in the military cockpit increases, pilots will suffer high levels of workload which could result in reduced performance and the loss of situational awareness. A DRA research program has been investigating the use of data-fused displays in decision support and has developed and laboratory-tested an explanatory tool for displaying information in air combat scenarios. The tool has been designed to provide pictorial explanations of data that maintain situational awareness by involving the pilot in the hostile aircraft threat assessment task. This paper reports a study carried out to validate the success of the explanatory tool in a realistic flight simulation facility. Aircrew were asked to perform a threat assessment task, either with or without the explanatory tool providing information in the form of missile launch success zone envelopes, while concurrently flying a waypoint course within set flight parameters. The results showed that there was a significant improvement (p less than 0.01) in threat assessment accuracy of 30% when using the explanatory tool. This threat assessment performance advantage was achieved without a trade-off with flying task performance. Situational awareness measures showed no general differences between the explanatory and control conditions, but significant learning effects suggested that the explanatory tool makes the task initially more intuitive and hence less demanding on the pilots' attentional resources. The paper concludes that DRA's data-fused explanatory tool is successful at improving threat assessment accuracy in a realistic simulated flying environment, and briefly discusses the requirements for further research in the area.

  20. Creating a Test Validated Structural Dynamic Finite Element Model of the Multi-Utility Technology Test Bed Aircraft

    Science.gov (United States)

    Pak, Chan-Gi; Truong, Samson S.

    2014-01-01

    Small modeling errors in the finite element model will eventually induce errors in the structural flexibility and mass, thus propagating into unpredictable errors in the unsteady aerodynamics and the control law design. One of the primary objectives of Multi Utility Technology Test Bed, X-56A, aircraft is the flight demonstration of active flutter suppression, and therefore in this study, the identification of the primary and secondary modes for the structural model tuning based on the flutter analysis of X-56A. The ground vibration test validated structural dynamic finite element model of the X-56A is created in this study. The structural dynamic finite element model of the X-56A is improved using a model tuning tool. In this study, two different weight configurations of the X-56A have been improved in a single optimization run.

  1. Detecting Smoking Events Using Accelerometer Data Collected Via Smartwatch Technology: Validation Study.

    Science.gov (United States)

    Cole, Casey A; Anshari, Dien; Lambert, Victoria; Thrasher, James F; Valafar, Homayoun

    2017-12-13

    Smoking is the leading cause of preventable death in the world today. Ecological research on smoking in context currently relies on self-reported smoking behavior. Emerging smartwatch technology may more objectively measure smoking behavior by automatically detecting smoking sessions using robust machine learning models. This study aimed to examine the feasibility of detecting smoking behavior using smartwatches. The second aim of this study was to compare the success of observing smoking behavior with smartwatches to that of conventional self-reporting. A convenience sample of smokers was recruited for this study. Participants (N=10) recorded 12 hours of accelerometer data using a mobile phone and smartwatch. During these 12 hours, they engaged in various daily activities, including smoking, for which they logged the beginning and end of each smoking session. Raw data were classified as either smoking or nonsmoking using a machine learning model for pattern recognition. The accuracy of the model was evaluated by comparing the output with a detailed description of a modeled smoking session. In total, 120 hours of data were collected from participants and analyzed. The accuracy of self-reported smoking was approximately 78% (96/123). Our model was successful in detecting 100 of 123 (81%) smoking sessions recorded by participants. After eliminating sessions from the participants that did not adhere to study protocols, the true positive detection rate of the smartwatch based-detection increased to more than 90%. During the 120 hours of combined observation time, only 22 false positive smoking sessions were detected resulting in a 2.8% false positive rate. Smartwatch technology can provide an accurate, nonintrusive means of monitoring smoking behavior in natural contexts. The use of machine learning algorithms for passively detecting smoking sessions may enrich ecological momentary assessment protocols and cessation intervention studies that often rely on self

  2. Precision Medicine, Cardiovascular Disease and Hunting Elephants.

    Science.gov (United States)

    Joyner, Michael J

    2016-01-01

    Precision medicine postulates improved prediction, prevention, diagnosis and treatment of disease based on patient specific factors especially DNA sequence (i.e., gene) variants. Ideas related to precision medicine stem from the much anticipated "genetic revolution in medicine" arising seamlessly from the human genome project (HGP). In this essay I deconstruct the concept of precision medicine and raise questions about the validity of the paradigm in general and its application to cardiovascular disease. Thus far precision medicine has underperformed based on the vision promulgated by enthusiasts. While niche successes for precision medicine are likely, the promises of broad based transformation should be viewed with skepticism. Open discussion and debate related to precision medicine are urgently needed to avoid misapplication of resources, hype, iatrogenic interventions, and distraction from established approaches with ongoing utility. Failure to engage in such debate will lead to negative unintended consequences from a revolution that might never come. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Precision time distribution within a deep space communications complex

    Science.gov (United States)

    Curtright, J. B.

    1972-01-01

    The Precision Time Distribution System (PTDS) at the Golstone Deep Space Communications Complex is a practical application of existing technology to the solution of a local problem. The problem was to synchronize four station timing systems to a master source with a relative accuracy consistently and significantly better than 10 microseconds. The solution involved combining a precision timing source, an automatic error detection assembly and a microwave distribution network into an operational system. Upon activation of the completed PTDS two years ago, synchronization accuracy at Goldstone (two station relative) was improved by an order of magnitude. It is felt that the validation of the PTDS mechanization is now completed. Other facilities which have site dispersion and synchronization accuracy requirements similar to Goldstone may find the PTDS mechanization useful in solving their problem. At present, the two station relative synchronization accuracy at Goldstone is better than one microsecond.

  4. Construction and validation of a tool to Assess the Use of Light Technologies at Intensive Care Units.

    Science.gov (United States)

    Marinho, Pabliane Matias Lordelo; Campos, Maria Pontes de Aguiar; Rodrigues, Eliana Ofélia Llapa; Gois, Cristiane Franca Lisboa; Barreto, Ikaro Daniel de Carvalho

    2016-12-19

    to construct and validate a tool to assess the use of light technologies by the nursing team at Intensive Care Units. methodological study in which the tool was elaborated by means of the psychometric method for construction based on the categorization of health technologies by Merhy and Franco, from the National Humanization Policy, using the Nursing Intervention Classification taxonomy to categorize the domains of the tool. Agreement Percentages and Content Validity Indices were used for the purpose of validation. The result of the application of the Interrater Agreement Percentage exceeded the recommended level of 80%, highlighting the relevance for the proposed theme in the assessment, with an agreement rate of 99%. the tool was validated with four domains (Bond, Autonomy, Welcoming and Management) and nineteen items that assess the use of light technologies at Intensive Care Units. construir e validar um instrumento para avaliação do uso de tecnologias leves, pela equipe de enfermagem, em Unidades de Terapia Intensiva. estudo metodológico no qual o instrumento foi elaborado utilizando o método psicométrico para construção com base na categorização das tecnologias em saúde de Merhy e Franco, da Política Nacional de Humanização, utilizando-se a taxonomia Nursing Intervention Classification para categorizar os domínios do instrumento. Utilizou-se o Percentual de Concordância e o Índice de Validade de Conteúdo (IVC) para validação. o resultado da aplicação do Percentual de Concordância entre os juízes foi superior ao recomendado de 80%, havendo destaque na avaliação da pertinência ao tema proposto, apresentando um percentual de concordância de 99%. o instrumento foi validado com quatro domínios (Vínculo, Autonomia, Acolhimento e Gestão) e dezenove itens que avaliam o uso das tecnologias leves em Unidade de Terapia Intensiva. construir y validar un instrumento para evaluación del uso de tecnologías leves, por el equipo de enfermer

  5. The Science of and Advanced Technology for Cost-Effective Manufacture of High Precision Engineering Products. Volume 5. Automatic Generation of Process Outlines of Forming and Machining Processes.

    Science.gov (United States)

    1986-08-01

    Circumscribing, (e.g. c-polygon - circumscribing polygon). or: subscript denoting: compressive. C-P - Computation Parameter. CAPM - computer aided process...technology. Assumptions about parts and processes apply to the bulk of them. J f I,%, Z Z" -, t . ,Wrg %%JJ but not necessarily to all of them. Deep...forming is the assumption about rigid perfectly plastic bodies. The introduction of elasto- plastic behavior refines these idealizations

  6. Thin films for precision optics

    International Nuclear Information System (INIS)

    Araujo, J.F.; Maurici, N.; Castro, J.C. de

    1983-01-01

    The technology of producing dielectric and/or metallic thin films for high precision optical components is discussed. Computer programs were developed in order to calculate and register, graphically, reflectance and transmittance spectra of multi-layer films. The technology of vacuum evaporation of several materials was implemented in our thin-films laboratory; various films for optics were then developed. The possibility of first calculate film characteristics and then produce the film is of great advantage since it reduces the time required to produce a new type of film and also reduces the cost of the project. (C.L.B.) [pt

  7. Epidemiology in wonderland: Big Data and precision medicine.

    Science.gov (United States)

    Saracci, Rodolfo

    2018-03-01

    Big Data and precision medicine, two major contemporary challenges for epidemiology, are critically examined from two different angles. In Part 1 Big Data collected for research purposes (Big research Data) and Big Data used for research although collected for other primary purposes (Big secondary Data) are discussed in the light of the fundamental common requirement of data validity, prevailing over "bigness". Precision medicine is treated developing the key point that high relative risks are as a rule required to make a variable or combination of variables suitable for prediction of disease occurrence, outcome or response to treatment; the commercial proliferation of allegedly predictive tests of unknown or poor validity is commented. Part 2 proposes a "wise epidemiology" approach to: (a) choosing in a context imprinted by Big Data and precision medicine-epidemiological research projects actually relevant to population health, (b) training epidemiologists, (c) investigating the impact on clinical practices and doctor-patient relation of the influx of Big Data and computerized medicine and (d) clarifying whether today "health" may be redefined-as some maintain in purely technological terms.

  8. Connecting Technological Innovation in Artificial Intelligence to Real-world Medical Practice through Rigorous Clinical Validation: What Peer-reviewed Medical Journals Could Do

    Science.gov (United States)

    2018-01-01

    Artificial intelligence (AI) is projected to substantially influence clinical practice in the foreseeable future. However, despite the excitement around the technologies, it is yet rare to see examples of robust clinical validation of the technologies and, as a result, very few are currently in clinical use. A thorough, systematic validation of AI technologies using adequately designed clinical research studies before their integration into clinical practice is critical to ensure patient benefit and safety while avoiding any inadvertent harms. We would like to suggest several specific points regarding the role that peer-reviewed medical journals can play, in terms of study design, registration, and reporting, to help achieve proper and meaningful clinical validation of AI technologies designed to make medical diagnosis and prediction, focusing on the evaluation of diagnostic accuracy efficacy. Peer-reviewed medical journals can encourage investigators who wish to validate the performance of AI systems for medical diagnosis and prediction to pay closer attention to the factors listed in this article by emphasizing their importance. Thereby, peer-reviewed medical journals can ultimately facilitate translating the technological innovations into real-world practice while securing patient safety and benefit.

  9. Connecting Technological Innovation in Artificial Intelligence to Real-world Medical Practice through Rigorous Clinical Validation: What Peer-reviewed Medical Journals Could Do.

    Science.gov (United States)

    Park, Seong Ho; Kressel, Herbert Y

    2018-05-28

    Artificial intelligence (AI) is projected to substantially influence clinical practice in the foreseeable future. However, despite the excitement around the technologies, it is yet rare to see examples of robust clinical validation of the technologies and, as a result, very few are currently in clinical use. A thorough, systematic validation of AI technologies using adequately designed clinical research studies before their integration into clinical practice is critical to ensure patient benefit and safety while avoiding any inadvertent harms. We would like to suggest several specific points regarding the role that peer-reviewed medical journals can play, in terms of study design, registration, and reporting, to help achieve proper and meaningful clinical validation of AI technologies designed to make medical diagnosis and prediction, focusing on the evaluation of diagnostic accuracy efficacy. Peer-reviewed medical journals can encourage investigators who wish to validate the performance of AI systems for medical diagnosis and prediction to pay closer attention to the factors listed in this article by emphasizing their importance. Thereby, peer-reviewed medical journals can ultimately facilitate translating the technological innovations into real-world practice while securing patient safety and benefit.

  10. In vivo cardiac nano-imaging: A new technology for high-precision analyses of sarcomere dynamics in the heart.

    Science.gov (United States)

    Shimozawa, Togo; Hirokawa, Erisa; Kobirumaki-Shimozawa, Fuyu; Oyama, Kotaro; Shintani, Seine A; Terui, Takako; Kushida, Yasuharu; Tsukamoto, Seiichi; Fujii, Teruyuki; Ishiwata, Shin'ichi; Fukuda, Norio

    2017-03-01

    The cardiac pump function is a result of a rise in intracellular Ca 2+ and the ensuing sarcomeric contractions [i.e., excitation-contraction (EC) coupling] in myocytes in various locations of the heart. In order to elucidate the heart's mechanical properties under various settings, cardiac imaging is widely performed in today's clinical as well as experimental cardiology by using echocardiogram, magnetic resonance imaging and computed tomography. However, because these common techniques detect local myocardial movements at a spatial resolution of ∼100 μm, our knowledge on the sub-cellular mechanisms of the physiology and pathophysiology of the heart in vivo is limited. This is because (1) EC coupling occurs in the μm partition in a myocyte and (2) cardiac sarcomeres generate active force upon a length change of ∼100 nm on a beat-to-beat basis. Recent advances in optical technologies have enabled measurements of intracellular Ca 2+ dynamics and sarcomere length displacements at high spatial and temporal resolution in the beating heart of living rodents. Future studies with these technologies are warranted to open a new era in cardiac research. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    Science.gov (United States)

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the

  12. Identification and Validation of SNP Markers Linked to Dwarf Traits Using SLAF-Seq Technology in Lagerstroemia

    Science.gov (United States)

    Ju, Yiqian; Jiao, Yao; Feng, Lu; Pan, Huitang; Cheng, Tangren; Zhang, Qixiang

    2016-01-01

    The genetic control of plant architecture is a promising approach to breed desirable cultivars, particularly in ornamental flowers. In this study, the F1 population (142 seedlings) derived from Lagerstroemia fauriei (non-dwarf) × L. indica ‘Pocomoke’ (dwarf) was phenotyped for six traits (plant height (PH), internode length (IL), internode number, primary lateral branch height (PLBH), secondary lateral branch height and primary branch number), and the IL and PLBH traits were positively correlated with the PH trait and considered representative indexes of PH. Fifty non-dwarf and dwarf seedlings were pooled and subjected to a specific-locus amplified fragment sequencing (SLAF-seq) method, which screened 1221 polymorphic markers. A total of 3 markers segregating between bulks were validated in the F1 population, with the M16337 and M38412 markers highly correlated with the IL trait and the M25207 marker highly correlated with the PLBH trait. These markers provide a predictability of approximately 80% using a single marker (M25207) and a predictability of 90% using marker combinations (M16337 + M25207) in the F1 population, which revealed that the IL and the PLBH traits, especially the PLBH, were the decisive elements for PH in terms of molecular regulation. Further validation was performed in the BC1 population and a set of 28 Lagerstroemia stocks using allele-specific PCR (AS-PCR) technology, and the results showed the stability and reliability of the SNP markers and the co-determination of PH by multiple genes. Our findings provide an important theoretical and practical basis for the early prediction and indirect selection of PH using the IL and the PLBH, and the detected SNPs may be useful for marker-assisted selection (MAS) in crape myrtle. PMID:27404662

  13. Precision medicine for psychopharmacology: a general introduction.

    Science.gov (United States)

    Shin, Cheolmin; Han, Changsu; Pae, Chi-Un; Patkar, Ashwin A

    2016-07-01

    Precision medicine is an emerging medical model that can provide accurate diagnoses and tailored therapeutic strategies for patients based on data pertaining to genes, microbiomes, environment, family history and lifestyle. Here, we provide basic information about precision medicine and newly introduced concepts, such as the precision medicine ecosystem and big data processing, and omics technologies including pharmacogenomics, pharamacometabolomics, pharmacoproteomics, pharmacoepigenomics, connectomics and exposomics. The authors review the current state of omics in psychiatry and the future direction of psychopharmacology as it moves towards precision medicine. Expert commentary: Advances in precision medicine have been facilitated by achievements in multiple fields, including large-scale biological databases, powerful methods for characterizing patients (such as genomics, proteomics, metabolomics, diverse cellular assays, and even social networks and mobile health technologies), and computer-based tools for analyzing large amounts of data.

  14. The newest precision measurement

    International Nuclear Information System (INIS)

    Lee, Jing Gu; Lee, Jong Dae

    1974-05-01

    This book introduces basic of precision measurement, measurement of length, limit gauge, measurement of angles, measurement of surface roughness, measurement of shapes and locations, measurement of outline, measurement of external and internal thread, gear testing, accuracy inspection of machine tools, three dimension coordinate measuring machine, digitalisation of precision measurement, automation of precision measurement, measurement of cutting tools, measurement using laser, and point of choosing length measuring instrument.

  15. Practical precision measurement

    International Nuclear Information System (INIS)

    Kwak, Ho Chan; Lee, Hui Jun

    1999-01-01

    This book introduces basic knowledge of precision measurement, measurement of length, precision measurement of minor diameter, measurement of angles, measurement of surface roughness, three dimensional measurement, measurement of locations and shapes, measurement of screw, gear testing, cutting tools testing, rolling bearing testing, and measurement of digitalisation. It covers height gauge, how to test surface roughness, measurement of plan and straightness, external and internal thread testing, gear tooth measurement, milling cutter, tab, rotation precision measurement, and optical transducer.

  16. [Precision and personalized medicine].

    Science.gov (United States)

    Sipka, Sándor

    2016-10-01

    The author describes the concept of "personalized medicine" and the newly introduced "precision medicine". "Precision medicine" applies the terms of "phenotype", "endotype" and "biomarker" in order to characterize more precisely the various diseases. Using "biomarkers" the homogeneous type of a disease (a "phenotype") can be divided into subgroups called "endotypes" requiring different forms of treatment and financing. The good results of "precision medicine" have become especially apparent in relation with allergic and autoimmune diseases. The application of this new way of thinking is going to be necessary in Hungary, too, in the near future for participants, controllers and financing boards of healthcare. Orv. Hetil., 2016, 157(44), 1739-1741.

  17. Precision Clock Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Tests and evaluates high-precision atomic clocks for spacecraft, ground, and mobile applications. Supports performance evaluation, environmental testing,...

  18. Spatial analysis of soybean canopy response to soybean cyst nematodes (Heterodera glycines) in eastern Arkansas: An approach to future precision agriculture technology application

    Science.gov (United States)

    Kulkarni, Subodh

    2008-10-01

    Heterodera glycines Ichinohe, commonly known as soybean cyst nematode (SCN) is a serious widespread pathogen of soybean in the US. Present research primarily investigated feasibility of detecting SCN infestation in the field using aerial images and ground level spectrometric sensing. Non-spatial and spatial linear regression analyses were performed to correlate SCN population densities with Normalized Difference Vegetation Index (NDVI) and Green NDVI (GNDVI) derived from soybean canopy spectra. Field data were obtained from two fields; Field A and B under different nematode control strategies in 2003 and 2004. Analysis of aerial image data from July 18, 2004 from the Field A showed a significant relationship between SCN population at planting and the GNDVI (R2=0.17 at p=0.0006). Linear regression analysis revealed that SCN had a little effect on yield (R2 =0.14, at p=0.0001, RMSEP=1052.42 kg ha-1) and GNDVI (R 2=0.17 at p=0.0006, RMSEP=0.087) derived from the aerial imagery on a single date. However, the spatial regression analysis based on spherical semivariogram showed that the RMSEP was 0.037 for the GNDVI on July 18, 2004 and 427.32 kg ha-1 for yield on October 14, 2003 indicating better model performance. For July 18, 2004 data from Field B, a relationship between NDVI and the cyst counts at planting was significant (R2=0.5 at p=0.0468). Non-spatial analyses of the ground level spectrometric data for the first field showed that NDVI and GNDVI were correlated with cyst counts at planting (R 2=0.34 and 0.27 at p=0.0015 and 0.0127, respectively), and GNDVI was correlated with eggs count at planting (R2= 0.27 at p=0.0118). Both NDVI and GNDVI were correlated with egg counts at flowering (R 2=0.34 and 0.27 at p=0.0013 and 0.0018, respectively). However, paired T test to validate the above relationships showed that, predicted values of NDVI and GNDVI were significantly different. The statistical evidences suggested that variability in vegetation indices was caused

  19. Validation of the integration of technology that measures additional "vascular" indices into an ambulatory blood pressure monitoring system.

    Science.gov (United States)

    Kotovskaya, Yulia V; Kobalava, Zhanna D; Orlov, Artemy V

    2014-01-01

    The objective of this study was to validate the novel integration of oscillometric (Vasotens(®)) technology into a BPLab(®) ambulatory blood pressure (BP) monitoring system to measure central BP, the aortic augmentation index, and pulse wave velocity (PWV) compared with the recommended and widely accepted tonometric method. The ARTERY Society guidelines for comparison of PWV measurement techniques were used as the basis for recruitment of 99 individuals (mean age 44±19 years, 52 males). The standard for comparison was the conventional "classic" SphygmoCor device. Accordance of the two methods was satisfactory (r=0.98, mean difference of 2.9±3.5 mmHg for central systolic BP; r=0.98, mean difference of -1.1±2.3 mmHg for central diastolic BP; r=0.83, mean difference of -2.6%±13% for aortic augmentation index; r=0.85, mean difference of 0.69±1.4 for PWV). The performance of Vasotens algorithms using an oscillometric ambulatory BP monitoring system is feasible for accurate diagnosis, risk assessment, and evaluation of the effects of antihypertensive drugs.

  20. Validation of the high-throughput marker technology DArT using the model plant Arabidopsis thaliana.

    Science.gov (United States)

    Wittenberg, Alexander H J; van der Lee, Theo; Cayla, Cyril; Kilian, Andrzej; Visser, Richard G F; Schouten, Henk J

    2005-08-01

    Diversity Arrays Technology (DArT) is a microarray-based DNA marker technique for genome-wide discovery and genotyping of genetic variation. DArT allows simultaneous scoring of hundreds of restriction site based polymorphisms between genotypes and does not require DNA sequence information or site-specific oligonucleotides. This paper demonstrates the potential of DArT for genetic mapping by validating the quality and molecular basis of the markers, using the model plant Arabidopsis thaliana. Restriction fragments from a genomic representation of the ecotype Landsberg erecta (Ler) were amplified by PCR, individualized by cloning and spotted onto glass slides. The arrays were then hybridized with labeled genomic representations of the ecotypes Columbia (Col) and Ler and of individuals from an F(2) population obtained from a Col x Ler cross. The scoring of markers with specialized software was highly reproducible and 107 markers could unambiguously be ordered on a genetic linkage map. The marker order on the genetic linkage map coincided with the order on the DNA sequence map. Sequencing of the Ler markers and alignment with the available Col genome sequence confirmed that the polymorphism in DArT markers is largely a result of restriction site polymorphisms.

  1. Achievement report for fiscal 1998 on research and development of technologies for creating high-performance materials under the industrial and scientific technology research and development project. Control of condensation-based precision structures (High-performance materials for power plant facilities); 1998 nendo dokusoteki kokino zairyo sosei gijutsu no kenkyu kaihatsu (hatsuden shisetsuyo koseinoka zairyo gijutsu kaihatsu) shukugokei seimitsu kozo seigyo no kenkyu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The goal is to prepare a base for the development of polymerizing catalysts and precision polymerization processes which will enable the arbitrary control of molecular weight, regularity, branching, and primary structures such as terminal groups, which effort will lead to a remarkable advancement in condensation polymerization and open-ring polymeric material performance. Endeavors are on to fulfill two separate purposes, that is, precision condensation polymerization and controlled open-ring polymerization. In the study of precision condensation polymerization, at issue are basic studies and the development of precision control technologies for arrangement, molecular weight, branching, and matrix condensation polymerization. Also at issue are the development of technologies of position selective oxidization polymerization and precision conjugate high-molecular condensation synthesis. Concerning open-ring control polymerization, precision control technologies will be developed involving branching, molecular weight, crosslinking, arrangement, and the structure of cyclocarbonate open-ring polymerization. Open-ring control polymerization technologies are also under study by use of organic metal complexes. A survey of technological trends is also explained. (NEDO)

  2. Laser fusion and precision engineering

    International Nuclear Information System (INIS)

    Nakai, Sadao

    1989-01-01

    The development of laser nuclear fusion energy for attaining the self supply of energy in Japan and establishing the future perspective as the nation is based in the wide fields of high level science and technology. Therefore to its promotion, large expectation is placed as the powerful traction for the development of creative science and technology which are particularly necessary in Japan. The research on laser nuclear fusion advances steadily in the elucidation of the physics of pellet implosion which is its basic concept and compressed plasma parameters. In September, 1986, the number of neutron generation 10 13 , and in October, 1988, the high density compression 600 times as high as solid density have been achieved. Based on these results, now the laser nuclear fusion is in the situation to begin the attainment of ignition condition for nuclear fusion and the realization of break even. The optical components, high power laser technology, fuel pellet production, high resolution measurement, the simulation of implosion using a supercomputer and so on are closely related to precision engineering. In this report, the mechanism of laser nuclear fusion, the present status of its research, and the basic technologies and precision engineering are described. (K.I.)

  3. Validation of the Technology Acceptance Measure for Pre-Service Teachers (TAMPST) on a Malaysian Sample: A Cross-Cultural Study

    Science.gov (United States)

    Teo, Timothy

    2010-01-01

    Purpose: The purpose of this paper is to assess the cross-cultural validity of the technology acceptance measure for pre-service teachers (TAMPST) on a Malaysian sample. Design/methodology/approach: A total of 193 pre-service teachers from a Malaysian university completed a survey questionnaire measuring their responses to five constructs in the…

  4. Fiscal 1998 R and D on original advanced material creation technology (development of precise structure control materials for oil refinery improvement). R and D result report on multi-dimensional polymers; 1998 nendo dokusoteki kokino zairyo sosei gijutsu no kenkyu kaihatsu (sekiyu seisei kodoka seimitsu kozo seigyo zairyo kaihatsu) seika hokokusho. Tajigen kukan polymer no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    For development of radical-controlled synthesis technology of aromatic compounds using enzyme-related catalysts and synthesis technology of ordered compounds, and development of synthesis technology of new polymer groups with non-covalent bond linkages and new topological structures, this R and D on multi-dimensional polymers is promoting 2 research themes, (1) precise polymer synthesis technology using enzyme-related catalysts, and (2) chemical synthesis technology for polymers with non-covalent bond linkages and new topological structures. The joint research on (1) precise polymer synthesis technology using enzyme-related catalysts established the high-yield synthesis technology of phenol dimer first in the world. The joint research first studied the synthesis using 2,6-dimethylphenol as monomer through synthesis of phenol groups using ferrosalen, and obtained the mixture of polymer components more than 10,000 in molecular weight and low-molecular weight components by using 1,4- dioxane as solvent. (NEDO)

  5. Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration: In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA).

    Science.gov (United States)

    Scheerlinck, Thierry; Polfliet, Mathias; Deklerck, Rudi; Van Gompel, Gert; Buls, Nico; Vandemeulebroucke, Jef

    2016-01-01

    We developed a marker-free automated CT-based spatial analysis (CTSA) method to detect stem-bone migration in consecutive CT datasets and assessed the accuracy and precision in vitro. Our aim was to demonstrate that in vitro accuracy and precision of CTSA is comparable to that of radiostereometric analysis (RSA). Stem and bone were segmented in 2 CT datasets and both were registered pairwise. The resulting rigid transformations were compared and transferred to an anatomically sound coordinate system, taking the stem as reference. This resulted in 3 translation parameters and 3 rotation parameters describing the relative amount of stem-bone displacement, and it allowed calculation of the point of maximal stem migration. Accuracy was evaluated in 39 comparisons by imposing known stem migration on a stem-bone model. Precision was estimated in 20 comparisons based on a zero-migration model, and in 5 patients without stem loosening. Limits of the 95% tolerance intervals (TIs) for accuracy did not exceed 0.28 mm for translations and 0.20° for rotations (largest standard deviation of the signed error (SD(SE)): 0.081 mm and 0.057°). In vitro, limits of the 95% TI for precision in a clinically relevant setting (8 comparisons) were below 0.09 mm and 0.14° (largest SD(SE): 0.012 mm and 0.020°). In patients, the precision was lower, but acceptable, and dependent on CT scan resolution. CTSA allows detection of stem-bone migration with an accuracy and precision comparable to that of RSA. It could be valuable for evaluation of subtle stem loosening in clinical practice.

  6. Feeling validated yet? A scoping review of the use of consumer-targeted wearable and mobile technology to measure and improve sleep.

    Science.gov (United States)

    Baron, Kelly Glazer; Duffecy, Jennifer; Berendsen, Mark A; Cheung Mason, Ivy; Lattie, Emily G; Manalo, Natalie C

    2017-12-20

    The objectives of this review were to evaluate the use of consumer-targeted wearable and mobile sleep monitoring technology, identify gaps in the literature and determine the potential for use in behavioral interventions. We undertook a scoping review of studies conducted in adult populations using consumer-targeted wearable technology or mobile devices designed to measure and/or improve sleep. After screening for inclusion/exclusion criteria, data were extracted from the articles by two co-authors. Articles included in the search were using wearable or mobile technology to estimate or evaluate sleep, published in English and conducted in adult populations. Our search returned 3897 articles and 43 met our inclusion criteria. Results indicated that the majority of studies focused on validating technology to measure sleep (n = 23) or were observational studies (n = 10). Few studies were used to identify sleep disorders (n = 2), evaluate response to interventions (n = 3) or deliver interventions (n = 5). In conclusion, the use of consumer-targeted wearable and mobile sleep monitoring technology has largely focused on validation of devices and applications compared with polysomnography (PSG) but opportunities exist for observational research and for delivery of behavioral interventions. Multidisciplinary research is needed to determine the uses of these technologies in interventions as well as the use in more diverse populations including sleep disorders and other patient populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  8. submitter LEP precision results

    CERN Document Server

    Kawamoto, T

    2001-01-01

    Precision measurements at LEP are reviewed, with main focus on the electroweak measurements and tests of the Standard Model. Constraints placed by the LEP measurements on possible new physics are also discussed.

  9. Description of precision colorimeter

    OpenAIRE

    Campos Acosta, Joaquín; Pons Aglio, Alicia; Corróns, Antonio

    1987-01-01

    Describes the use of a fully automatic, computer-controlled absolute spectroradiometer as a precision colorimeter. The chromaticity coordinates of several types of light sources have been obtained with this measurement system.

  10. NCI Precision Medicine

    Science.gov (United States)

    This illustration represents the National Cancer Institute’s support of research to improve precision medicine in cancer treatment, in which unique therapies treat an individual’s cancer based on specific genetic abnormalities of that person’s tumor.

  11. Precision Medicine-Nobody Is Average.

    Science.gov (United States)

    Vinks, A A

    2017-03-01

    Medicine gets personal and tailor-made treatments are underway. Hospitals have started to advertise their advanced genomic testing capabilities and even their disruptive technologies to help foster a culture of innovation. The prediction in the lay press is that in decades from now we may look back and see 2017 as the year precision medicine blossomed. It is all part of the Precision Medicine Initiative that takes into account individual differences in people's genes, environments, and lifestyles. © 2017 ASCPT.

  12. Air Traffic Management Technology Demostration Phase 1 (ATD) Interval Management for Near-Term Operations Validation of Acceptability (IM-NOVA) Experiment

    Science.gov (United States)

    Kibler, Jennifer L.; Wilson, Sara R.; Hubbs, Clay E.; Smail, James W.

    2015-01-01

    The Interval Management for Near-term Operations Validation of Acceptability (IM-NOVA) experiment was conducted at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) in support of the NASA Airspace Systems Program's Air Traffic Management Technology Demonstration-1 (ATD-1). ATD-1 is intended to showcase an integrated set of technologies that provide an efficient arrival solution for managing aircraft using Next Generation Air Transportation System (NextGen) surveillance, navigation, procedures, and automation for both airborne and ground-based systems. The goal of the IMNOVA experiment was to assess if procedures outlined by the ATD-1 Concept of Operations were acceptable to and feasible for use by flight crews in a voice communications environment when used with a minimum set of Flight Deck-based Interval Management (FIM) equipment and a prototype crew interface. To investigate an integrated arrival solution using ground-based air traffic control tools and aircraft Automatic Dependent Surveillance-Broadcast (ADS-B) tools, the LaRC FIM system and the Traffic Management Advisor with Terminal Metering and Controller Managed Spacing tools developed at the NASA Ames Research Center (ARC) were integrated into LaRC's Air Traffic Operations Laboratory (ATOL). Data were collected from 10 crews of current 757/767 pilots asked to fly a high-fidelity, fixed-based simulator during scenarios conducted within an airspace environment modeled on the Dallas-Fort Worth (DFW) Terminal Radar Approach Control area. The aircraft simulator was equipped with the Airborne Spacing for Terminal Area Routes (ASTAR) algorithm and a FIM crew interface consisting of electronic flight bags and ADS-B guidance displays. Researchers used "pseudo-pilot" stations to control 24 simulated aircraft that provided multiple air traffic flows into the DFW International Airport, and recently retired DFW air traffic controllers served as confederate Center, Feeder, Final

  13. Explicit Covariance Matrix for Particle Measurement Precision

    CERN Document Server

    Karimäki, Veikko

    1997-01-01

    We derive explicit and precise formulae for 3 by 3 error matrix of the particle transverse momentum, direction and impact parameter. The error matrix elements are expressed as functions of up to fourth order statistical moments of the measured coordinates. The formulae are valid for any curvature and track length in case of negligible multiple scattering.

  14. Knowledge of Precision Farming Beneficiaries

    Directory of Open Access Journals (Sweden)

    A.V. Greena

    2016-05-01

    Full Text Available Precision Farming is one of the many advanced farming practices that make production more efficient by better resource management and reducing wastage. TN-IAMWARM is a world bank funded project aims to improve the farm productivity and income through better water management. The present study was carried out in Kambainallur sub basin of Dharmapuri district with 120 TN-IAMWARM beneficiaries as respondents. The result indicated that more than three fourth (76.67 % of the respondents had high level of knowledge on precision farming technologies which was made possible by the implementation of TN-IAMWARM project. The study further revealed that educational status, occupational status and exposure to agricultural messages had a positive and significant contribution to the knowledge level of the respondents at 0.01 level of probability whereas experience in precision farming and social participation had a positive and significant contribution at 0.05 level of probability.

  15. Precision Strike Technology Symposium (PSTS 09)

    Science.gov (United States)

    2009-10-29

    Control System) AUR (All-Up-Round) UHF SATCOM GPS JIC Threat and Target Data NGA Mapping, Charting & Geodesy 5 0 IRAQ SAU DI AR ABIA OM AN EM IRA TES JO...d M il it ary Ci ty Abu Dhabi qom Ahraz Shiraz Esfahan Yaz d Kerman Rafha 5 0 IRAQ SAU DI AR ABIA OM AN EM IRA TES JO RDAN SYRIA PAKI ST AN

  16. Epistemology, Ethics, and Progress in Precision Medicine.

    Science.gov (United States)

    Hey, Spencer Phillips; Barsanti-Innes, Brianna

    2016-01-01

    The emerging paradigm of precision medicine strives to leverage the tools of molecular biology to prospectively tailor treatments to the individual patient. Fundamental to the success of this movement is the discovery and validation of "predictive biomarkers," which are properties of a patient's biological specimens that can be assayed in advance of therapy to inform the treatment decision. Unfortunately, research into biomarkers and diagnostics for precision medicine has fallen well short of expectations. In this essay, we examine the portfolio of research activities into the excision repair cross complement group 1 (ERCC1) gene as a predictive biomarker for precision lung cancer therapy as a case study in elucidating the epistemological and ethical obstacles to developing new precision medicines.

  17. Fiscal 1997 project on the R and D of industrial scientific technology under consignment from NEDO. Report on the results of the R and D of technologies to invent original high-functional materials (development of precise structure control materials for enhancement of oil refining); 1997 nendo sangyo kagaku gijutsu kenkyu kaihatsu jigyo Shin Energy Sangyo Gijutsu Sogo Kaihatsu Kiko itaku. Dokusoteki kokino zairyo sosei gijutsu no kenkyu kaihatsu (sekiyu seisei kodoka seimitsu kozo seigyo zairyo kaihatsu) seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The paper described the R and D of technologies for creating original high-functional materials under the R and D system of industrial scientific technology. Japan chemical Innovation Institute (JCII) is conducting intensive joint researches under consignment from NEDO with private companies, universities and national research institutes. Among those, the paper reported the fiscal 1997 results of the following two researches conducted as development of precise structure control materials for enhancement of oil refining: precision catalytic polymerization and multi-dimensional space polymer. As to the precision catalytic polymerization, the paper is aimed at developing base technologies for the molecular weight and stereoregularity by which remarkable improvement in performance of addition polymerization type polymer can be expected, and on the development of a polymerization catalyst which arbitarily controls the primary structure such as end group structure and of a precision addition polymerization process. Subthemes are addition polymerization with limit and oriented catalytic polymerization. In relation to multi-dimensional space polymer, the paper is aimed at developing highly selective polymerization technology of aromatic compounds using enzyme related catalysts and synthesis technology of regular structure polymer, and synthesis technology of new polymer group having a new chain pattern except covalent bond/new polymer group having characteristics in three-dimensional space geometric structure. 244 refs,, 160 figs., 94 tabs.

  18. Laser precision microfabrication in Japan

    Science.gov (United States)

    Miyamoto, Isamu; Ooie, Toshihiko; Takeno, Shozui

    2000-11-01

    Electronic devices such as handy phones and micro computers have been rapidly expanding their market recent years due to their enhanced performance, down sizing and cost down. This has been realized by the innovation in the precision micro- fabrication technology of semiconductors and printed wiring circuit boards (PWB) where laser technologies such as lithography, drilling, trimming, welding and soldering play an important role. In phot lithography, for instance, KrF excimer lasers having a resolution of 0.18 micrometers has been used in production instead of mercury lamp. Laser drilling of PWB has been increased up to over 1000 holes per second, and approximately 800 laser drilling systems of PWB are expected to be delivered in the world market this year, and most of these laser processing systems are manufactured in Japan. Trend of laser micro-fabrication in Japanese industry is described along with recent topics of R&D, government supported project and future tasks of industrial laser precision micro-fabrication on the basis of the survey conducted by Japan laser Processing Society.

  19. Precision Experiments at LEP

    CERN Document Server

    de Boer, Wim

    2015-01-01

    The Large Electron Positron Collider (LEP) established the Standard Model (SM) of particle physics with unprecedented precision, including all its radiative corrections. These led to predictions for the masses of the top quark and Higgs boson, which were beautifully confirmed later on. After these precision measurements the Nobel Prize in Physics was awarded in 1999 jointly to 't Hooft and Veltman "for elucidating the quantum structure of electroweak interactions in physics". Another hallmark of the LEP results were the precise measurements of the gauge coupling constants, which excluded unification of the forces within the SM, but allowed unification within the supersymmetric extension of the SM. This increased the interest in Supersymmetry (SUSY) and Grand Unified Theories, especially since the SM has no candidate for the elusive dark matter, while Supersymmetry provides an excellent candidate for dark matter. In addition, Supersymmetry removes the quadratic divergencies of the SM and {\\it predicts} the Hig...

  20. Precision muonium spectroscopy

    International Nuclear Information System (INIS)

    Jungmann, Klaus P.

    2016-01-01

    The muonium atom is the purely leptonic bound state of a positive muon and an electron. It has a lifetime of 2.2 µs. The absence of any known internal structure provides for precision experiments to test fundamental physics theories and to determine accurate values of fundamental constants. In particular ground state hyperfine structure transitions can be measured by microwave spectroscopy to deliver the muon magnetic moment. The frequency of the 1s–2s transition in the hydrogen-like atom can be determined with laser spectroscopy to obtain the muon mass. With such measurements fundamental physical interactions, in particular quantum electrodynamics, can also be tested at highest precision. The results are important input parameters for experiments on the muon magnetic anomaly. The simplicity of the atom enables further precise experiments, such as a search for muonium–antimuonium conversion for testing charged lepton number conservation and searches for possible antigravity of muons and dark matter. (author)

  1. Precision genome editing

    DEFF Research Database (Denmark)

    Steentoft, Catharina; Bennett, Eric P; Schjoldager, Katrine Ter-Borch Gram

    2014-01-01

    Precise and stable gene editing in mammalian cell lines has until recently been hampered by the lack of efficient targeting methods. While different gene silencing strategies have had tremendous impact on many biological fields, they have generally not been applied with wide success in the field...... of glycobiology, primarily due to their low efficiencies, with resultant failure to impose substantial phenotypic consequences upon the final glycosylation products. Here, we review novel nuclease-based precision genome editing techniques enabling efficient and stable gene editing, including gene disruption...... by introducing single or double-stranded breaks at a defined genomic sequence. We here compare and contrast the different techniques and summarize their current applications, highlighting cases from the field of glycobiology as well as pointing to future opportunities. The emerging potential of precision gene...

  2. Precision electron polarimetry

    International Nuclear Information System (INIS)

    Chudakov, E.

    2013-01-01

    A new generation of precise Parity-Violating experiments will require a sub-percent accuracy of electron beam polarimetry. Compton polarimetry can provide such accuracy at high energies, but at a few hundred MeV the small analyzing power limits the sensitivity. Mo/ller polarimetry provides a high analyzing power independent on the beam energy, but is limited by the properties of the polarized targets commonly used. Options for precision polarimetry at 300 MeV will be discussed, in particular a proposal to use ultra-cold atomic hydrogen traps to provide a 100%-polarized electron target for Mo/ller polarimetry

  3. A passion for precision

    CERN Multimedia

    CERN. Geneva. Audiovisual Unit

    2006-01-01

    For more than three decades, the quest for ever higher precision in laser spectroscopy of the simple hydrogen atom has inspired many advances in laser, optical, and spectroscopic techniques, culminating in femtosecond laser optical frequency combs as perhaps the most precise measuring tools known to man. Applications range from optical atomic clocks and tests of QED and relativity to searches for time variations of fundamental constants. Recent experiments are extending frequency comb techniques into the extreme ultraviolet. Laser frequency combs can also control the electric field of ultrashort light pulses, creating powerful new tools for the emerging field of attosecond science.

  4. Improving Precision of Types

    DEFF Research Database (Denmark)

    Winther, Johnni

    Types in programming languages provide a powerful tool for the programmer to document the code so that a large aspect of the intent can not only be presented to fellow programmers but also be checked automatically by compilers. The precision with which types model the behavior of programs...... is crucial to the quality of these automated checks, and in this thesis we present three different improvements to the precision of types in three different aspects of the Java programming language. First we show how to extend the type system in Java with a new type which enables the detection of unintended...

  5. Algorithm Design and Validation for Adaptive Nonlinear Control Enhancement (ADVANCE) Technology Development for Resilient Flight Control, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — SSCI proposes to develop and test a framework referred to as the ADVANCE (Algorithm Design and Validation for Adaptive Nonlinear Control Enhancement), within which...

  6. Precision physics at LHC

    International Nuclear Information System (INIS)

    Hinchliffe, I.

    1997-05-01

    In this talk the author gives a brief survey of some physics topics that will be addressed by the Large Hadron Collider currently under construction at CERN. Instead of discussing the reach of this machine for new physics, the author gives examples of the types of precision measurements that might be made if new physics is discovered

  7. Precision Muonium Spectroscopy

    NARCIS (Netherlands)

    Jungmann, Klaus P.

    2016-01-01

    The muonium atom is the purely leptonic bound state of a positive muon and an electron. It has a lifetime of 2.2 mu s. The absence of any known internal structure provides for precision experiments to test fundamental physics theories and to determine accurate values of fundamental constants. In

  8. What is precision medicine?

    Science.gov (United States)

    König, Inke R; Fuchs, Oliver; Hansen, Gesine; von Mutius, Erika; Kopp, Matthias V

    2017-10-01

    The term "precision medicine" has become very popular over recent years, fuelled by scientific as well as political perspectives. Despite its popularity, its exact meaning, and how it is different from other popular terms such as "stratified medicine", "targeted therapy" or "deep phenotyping" remains unclear. Commonly applied definitions focus on the stratification of patients, sometimes referred to as a novel taxonomy, and this is derived using large-scale data including clinical, lifestyle, genetic and further biomarker information, thus going beyond the classical "signs-and-symptoms" approach.While these aspects are relevant, this description leaves open a number of questions. For example, when does precision medicine begin? In which way does the stratification of patients translate into better healthcare? And can precision medicine be viewed as the end-point of a novel stratification of patients, as implied, or is it rather a greater whole?To clarify this, the aim of this paper is to provide a more comprehensive definition that focuses on precision medicine as a process. It will be shown that this proposed framework incorporates the derivation of novel taxonomies and their role in healthcare as part of the cycle, but also covers related terms. Copyright ©ERS 2017.

  9. Potentials and prospects of precision agriculture in pakistan - a review

    International Nuclear Information System (INIS)

    Mahmood, H.S.; Ahmad, T.; Saeed, M.A.; Iqbal, M.

    2013-01-01

    Precision agriculture is to fine-tune the agricultural production system by emergence and convergence of several information-based technologies for enhancing profit and reducing environmental risks. These technologies have demonstrated to provide benefits to farmers as well as reduced environmental stresses in the developed world. Present paper provides an overview of precision agriculture and examines the potentials, prospects, implications, issues and relevance of precision agricultural applications in Pakistani agricultural system. There is a scope of many precision technologies to be implemented in the country. In this perspective, farmers and government authorities should look forward to adopt new and sustainable technologies to increase the efficiency of available resources and reduce the input costs. Before this, the effectiveness of precision technologies needs to be realised in Pakistan through field experiments and land management practices. (author)

  10. Transcriptomic SNP discovery for custom genotyping arrays: impacts of sequence data, SNP calling method and genotyping technology on the probability of validation success.

    Science.gov (United States)

    Humble, Emily; Thorne, Michael A S; Forcada, Jaume; Hoffman, Joseph I

    2016-08-26

    Single nucleotide polymorphism (SNP) discovery is an important goal of many studies. However, the number of 'putative' SNPs discovered from a sequence resource may not provide a reliable indication of the number that will successfully validate with a given genotyping technology. For this it may be necessary to account for factors such as the method used for SNP discovery and the type of sequence data from which it originates, suitability of the SNP flanking sequences for probe design, and genomic context. To explore the relative importance of these and other factors, we used Illumina sequencing to augment an existing Roche 454 transcriptome assembly for the Antarctic fur seal (Arctocephalus gazella). We then mapped the raw Illumina reads to the new hybrid transcriptome using BWA and BOWTIE2 before calling SNPs with GATK. The resulting markers were pooled with two existing sets of SNPs called from the original 454 assembly using NEWBLER and SWAP454. Finally, we explored the extent to which SNPs discovered using these four methods overlapped and predicted the corresponding validation outcomes for both Illumina Infinium iSelect HD and Affymetrix Axiom arrays. Collating markers across all discovery methods resulted in a global list of 34,718 SNPs. However, concordance between the methods was surprisingly poor, with only 51.0 % of SNPs being discovered by more than one method and 13.5 % being called from both the 454 and Illumina datasets. Using a predictive modeling approach, we could also show that SNPs called from the Illumina data were on average more likely to successfully validate, as were SNPs called by more than one method. Above and beyond this pattern, predicted validation outcomes were also consistently better for Affymetrix Axiom arrays. Our results suggest that focusing on SNPs called by more than one method could potentially improve validation outcomes. They also highlight possible differences between alternative genotyping technologies that could be

  11. Adaptation of the Mathematics and Technology Attitudes Scale (MTAS) into Turkish: Validity and Reliability Studies for Middle School Students

    Science.gov (United States)

    Tabuk, Mesut

    2018-01-01

    The paper aims to present the adaptation study of "The Mathematics and Technology Attitudes Scale (MTAS)" into Turkish. The original form MTAS was developed by Pierce, Stacey and Barkatsas (2007) in order to investigate the effect of five different variables in learning mathematics with technology. The original form of the attitudes…

  12. Equity and Value in 'Precision Medicine'.

    Science.gov (United States)

    Gray, Muir; Lagerberg, Tyra; Dombrádi, Viktor

    2017-04-01

    Precision medicine carries huge potential in the treatment of many diseases, particularly those with high-penetrance monogenic underpinnings. However, precision medicine through genomic technologies also has ethical implications. We will define allocative, personal, and technical value ('triple value') in healthcare and how this relates to equity. Equity is here taken to be implicit in the concept of triple value in countries that have publicly funded healthcare systems. It will be argued that precision medicine risks concentrating resources to those that already experience greater access to healthcare and power in society, nationally as well as globally. Healthcare payers, clinicians, and patients must all be involved in optimising the potential of precision medicine, without reducing equity. Throughout, the discussion will refer to the NHS RightCare Programme, which is a national initiative aiming to improve value and equity in the context of NHS England.

  13. Five critical elements to ensure the precision medicine.

    Science.gov (United States)

    Chen, Chengshui; He, Mingyan; Zhu, Yichun; Shi, Lin; Wang, Xiangdong

    2015-06-01

    The precision medicine as a new emerging area and therapeutic strategy has occurred and was practiced in the individual and brought unexpected successes, and gained high attentions from professional and social aspects as a new path to improve the treatment and prognosis of patients. There will be a number of new components to appear or be discovered, of which clinical bioinformatics integrates clinical phenotypes and informatics with bioinformatics, computational science, mathematics, and systems biology. In addition to those tools, precision medicine calls more accurate and repeatable methodologies for the identification and validation of gene discovery. Precision medicine will bring more new therapeutic strategies, drug discovery and development, and gene-oriented treatment. There is an urgent need to identify and validate disease-specific, mechanism-based, or epigenetics-dependent biomarkers to monitor precision medicine, and develop "precision" regulations to guard the application of precision medicine.

  14. Transforming Cancer Prevention through Precision Medicine and Immune-oncology.

    Science.gov (United States)

    Kensler, Thomas W; Spira, Avrum; Garber, Judy E; Szabo, Eva; Lee, J Jack; Dong, Zigang; Dannenberg, Andrew J; Hait, William N; Blackburn, Elizabeth; Davidson, Nancy E; Foti, Margaret; Lippman, Scott M

    2016-01-01

    We have entered a transformative period in cancer prevention (including early detection). Remarkable progress in precision medicine and immune-oncology, driven by extraordinary recent advances in genome-wide sequencing, big-data analytics, blood-based technologies, and deep understanding of the tumor immune microenvironment (TME), has provided unprecedented possibilities to study the biology of premalignancy. The pace of research and discovery in precision medicine and immunoprevention has been astonishing and includes the following clinical firsts reported in 2015: driver mutations detected in circulating cell-free DNA in patients with premalignant lesions (lung); clonal hematopoiesis shown to be a premalignant state; molecular selection in chemoprevention randomized controlled trial (RCT; oral); striking efficacy in RCT of combination chemoprevention targeting signaling pathway alterations mechanistically linked to germline mutation (duodenum); molecular markers for early detection validated for lung cancer and showing promise for pancreatic, liver, and ovarian cancer. Identification of HPV as the essential cause of a major global cancer burden, including HPV16 as the single driver of an epidemic of oropharyngeal cancer in men, provides unique opportunities for the dissemination and implementation of public health interventions. Important to immunoprevention beyond viral vaccines, genetic drivers of premalignant progression were associated with increasing immunosuppressive TME; and Kras vaccine efficacy in pancreas genetically engineered mouse (GEM) model required an inhibitory adjuvant (Treg depletion). In addition to developing new (e.g., epigenetic) TME regulators, recent mechanistic studies of repurposed drugs (aspirin, metformin, and tamoxifen) have identified potent immune activity. Just as precision medicine and immune-oncology are revolutionizing cancer therapy, these approaches are transforming cancer prevention. Here, we set out a brief agenda for the

  15. Validation of a Full-Immersion Simulation Platform for Percutaneous Nephrolithotomy Using Three-Dimensional Printing Technology.

    Science.gov (United States)

    Ghazi, Ahmed; Campbell, Timothy; Melnyk, Rachel; Feng, Changyong; Andrusco, Alex; Stone, Jonathan; Erturk, Erdal

    2017-12-01

    The restriction of resident hours with an increasing focus on patient safety and a reduced caseload has impacted surgical training. A complex and complication prone procedure such as percutaneous nephrolithotomy (PCNL) with a steep learning curve may create an unsafe environment for hands-on resident training. In this study, we validate a high fidelity, inanimate PCNL model within a full-immersion simulation environment. Anatomically correct models of the human pelvicaliceal system, kidney, and relevant adjacent structures were created using polyvinyl alcohol hydrogels and three-dimensional-printed injection molds. All steps of a PCNL were simulated including percutaneous renal access, nephroscopy, and lithotripsy. Five experts (>100 caseload) and 10 novices (simulation. Face and content validity were calculated using model ratings for similarity to the real procedure and usefulness as a training tool. Differences in performance among groups with various levels of experience using clinically relevant procedural metrics were used to calculate construct validity. The model was determined to have an excellent face and content validity with an average score of 4.5/5.0 and 4.6/5.0, respectively. There were significant differences between novice and expert operative metrics including mean fluoroscopy time, the number of percutaneous access attempts, and number of times the needle was repositioned. Experts achieved better stone clearance with fewer procedural complications. We demonstrated the face, content, and construct validity of an inanimate, full task trainer for PCNL. Construct validity between experts and novices was demonstrated using incorporated procedural metrics, which permitted the accurate assessment of performance. While hands-on training under supervision remains an integral part of any residency, this full-immersion simulation provides a comprehensive tool for surgical skills development and evaluation before hands-on exposure.

  16. Precision synchrotron radiation detectors

    International Nuclear Information System (INIS)

    Levi, M.; Rouse, F.; Butler, J.

    1989-03-01

    Precision detectors to measure synchrotron radiation beam positions have been designed and installed as part of beam energy spectrometers at the Stanford Linear Collider (SLC). The distance between pairs of synchrotron radiation beams is measured absolutely to better than 28 /mu/m on a pulse-to-pulse basis. This contributes less than 5 MeV to the error in the measurement of SLC beam energies (approximately 50 GeV). A system of high-resolution video cameras viewing precisely-aligned fiducial wire arrays overlaying phosphorescent screens has achieved this accuracy. Also, detectors of synchrotron radiation using the charge developed by the ejection of Compton-recoil electrons from an array of fine wires are being developed. 4 refs., 5 figs., 1 tab

  17. A passion for precision

    CERN Multimedia

    CERN. Geneva

    2006-01-01

    For more than three decades, the quest for ever higher precision in laser spectroscopy of the simple hydrogen atom has inspired many advances in laser, optical, and spectroscopic techniques, culminating in femtosecond laser optical frequency combs  as perhaps the most precise measuring tools known to man. Applications range from optical atomic clocks and tests of QED and relativity to searches for time variations of fundamental constants. Recent experiments are extending frequency comb techniques into the extreme ultraviolet. Laser frequency combs can also control the electric field of ultrashort light pulses, creating powerful new tools for the emerging field of attosecond science.Organiser(s): L. Alvarez-Gaume / PH-THNote: * Tea & coffee will be served at 16:00.

  18. Quad precision delay generator

    International Nuclear Information System (INIS)

    Krishnan, Shanti; Gopalakrishnan, K.R.; Marballi, K.R.

    1997-01-01

    A Quad Precision Delay Generator delays a digital edge by a programmed amount of time, varying from nanoseconds to microseconds. The output of this generator has an amplitude of the order of tens of volts and rise time of the order of nanoseconds. This was specifically designed and developed to meet the stringent requirements of the plasma focus experiments. Plasma focus is a laboratory device for producing and studying nuclear fusion reactions in hot deuterium plasma. 3 figs

  19. Management of the General Process of Parenteral Nutrition Using mHealth Technologies: Evaluation and Validation Study.

    Science.gov (United States)

    Cervera Peris, Mercedes; Alonso Rorís, Víctor Manuel; Santos Gago, Juan Manuel; Álvarez Sabucedo, Luis; Wanden-Berghe, Carmina; Sanz-Valero, Javier

    2018-04-03

    Any system applied to the control of parenteral nutrition (PN) ought to prove that the process meets the established requirements and include a repository of records to allow evaluation of the information about PN processes at any time. The goal of the research was to evaluate the mobile health (mHealth) app and validate its effectiveness in monitoring the management of the PN process. We studied the evaluation and validation of the general process of PN using an mHealth app. The units of analysis were the PN bags prepared and administered at the Son Espases University Hospital, Palma, Spain, from June 1 to September 6, 2016. For the evaluation of the app, we used the Poststudy System Usability Questionnaire and subsequent analysis with the Cronbach alpha coefficient. Validation was performed by checking the compliance of control for all operations on each of the stages (validation and transcription of the prescription, preparation, conservation, and administration) and by monitoring the operative control points and critical control points. The results obtained from 387 bags were analyzed, with 30 interruptions of administration. The fulfillment of stages was 100%, including noncritical nonconformities in the storage control. The average deviation in the weight of the bags was less than 5%, and the infusion time did not present deviations greater than 1 hour. The developed app successfully passed the evaluation and validation tests and was implemented to perform the monitoring procedures for the overall PN process. A new mobile solution to manage the quality and traceability of sensitive medicines such as blood-derivative drugs and hazardous drugs derived from this project is currently being deployed. ©Mercedes Cervera Peris, Víctor Manuel Alonso Rorís, Juan Manuel Santos Gago, Luis Álvarez Sabucedo, Carmina Wanden-Berghe, Javier Sanz-Valero. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 03.04.2018.

  20. Using smart card technology to monitor the eating habits of children in a school cafeteria: 1. Developing and validating the methodology.

    Science.gov (United States)

    Lambert, N; Plumb, J; Looise, B; Johnson, I T; Harvey, I; Wheeler, C; Robinson, M; Rolfe, P

    2005-08-01

    The aim of the study was to test the feasibility of using smart card technology to track the eating behaviours of nearly a thousand children in a school cafeteria. Within a large boys' school a smart card based system was developed that was capable of providing a full electronic audit of all the individual transactions that occurred within the cafeteria. This dataset was interfaced to an electronic version of the McCance and Widdowson composition of foods dataset. The accuracy of the smart card generated data and the influence of portion size and wastage were determined empirically during two 5-day trials. The smart card system created succeeded in generating precise data on the food choices made by hundreds of children over an indefinite time period. The data was expanded to include a full nutrient analysis of all the foods chosen. The accuracy of this information was only constrained by the limitations facing all food composition research, e.g. variations in recipes, portion sizes, cooking practices, etc. Although technically possible to introduce wastage correction factors into the software, thereby providing information upon foods consumed, this was not seen as universally practical. The study demonstrated the power of smart card technology for monitoring food/nutrient choice over limitless time in environments such as school cafeterias. The strengths, limitations and applications of such technology are discussed.

  1. Translation and validation of the assistive technology device predisposition assessment in Greek in order to assess satisfaction with use of the selected assistive device.

    Science.gov (United States)

    Koumpouros, Yiannis; Papageorgiou, Effie; Karavasili, Alexandra; Alexopoulou, Despoina

    2017-07-01

    To examine the Assistive Technology Device Predisposition Assessment scale and provide evidence of validity and reliability of the Greek version. We translated and adapted the original instrument in Greek according to the most well-known guidelines recommendations. Field test studies were conducted in a rehabilitation hospital to validate the appropriateness of the final results. Ratings of the different items were statistically analyzed. We recruited 115 subjects who were administered the Form E of the original questionnaire. The experimental analysis conducted revealed a three subscales structure: (i) Adaptability, (ii) Fit to Use, and (iii) Socializing. According to the results of our study the three subscales measure different constructs. Reliability measures (ICC = 0.981, Pearson's correlation = 0.963, Cronbach's α = 0.701) yielded high values. Test-retest outcome showed great stability. This is the first study, at least to the knowledge of the authors, which focuses merely on measuring the satisfaction of the users from the used assistive device, while exploring the Assistive Technology Device Predisposition Assessment - Device Form in such depth. According to the results, it is a stable, valid and reliable instrument and applicable to the Greek population. Thus, it can be used to measure the satisfaction of patients with assistive devices. Implications for Rehabilitation The paper explores the cultural adaptability and applicability of ATD PA - Device Form. ATD PA - Device Form can be used to assess user satisfaction by the selected assistive device. ATD PA - Device Form is a valid and reliable instrument in measuring users' satisfaction in Greekreality.

  2. Development of basic technology for instrumentation and control - Development of digital automatic supervisory limitation system and its design= validation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jung In; Chung, Sung Wook; Koh, Won Seok [Kyungwon University, Sungman (Korea, Republic of); Suh, Duk Young; Cheon, Sei Young [Kyunghee University, Seoul (Korea, Republic of); Lee, Sang Kyung; Kim, Sung Hun [Seoul National University, Seoul (Korea, Republic of)

    1995-07-01

    A major objective of the project is to develop a digital automatic supervisory limitation system and validate its design for the next generation= nuclear power plant. The limitation system assures that the plant does not exceed the operating limits by regulation the plant operations through on-line monitoring the operating margins of the critical parameters. A new conceptual model of power maneuverability has been proposed for the design of the limitation system and for its validation. Also, the limitation system monitors overall operation processes throughout a nuclear power plant by implementing hierarchical communication networks. Based on the conceptual design in software of the 1 st year results, the detailed design of the limitation system has been performed during the 2 nd year with constructing a prototype digital system. The system consists of the software module for plant simulation and the hardware module for implementation of limitation system and the associated interfaces in hardware. The limitation algorithm were implemented into the microprocessor and the interfaces were realized through the I/O modules. Also, these modules are incorporated into the communication networks. The products of the project could be directly applicable to the following nuclear unit adopting the limitation system, providing the bumpless transition to the commercial design phase. And the prototype evaluation scheme will be very useful for the succeeding studies related to the digital nuclear I and C fields, such as fault-tolerance design methods, software verification and validation and response time execution of digital systems. 69 refs., 3 tabs., 44 figs. (author)

  3. Precision electroweak measurements

    International Nuclear Information System (INIS)

    Demarteau, M.

    1996-11-01

    Recent electroweak precision measurements fro e + e - and p anti p colliders are presented. Some emphasis is placed on the recent developments in the heavy flavor sector. The measurements are compared to predictions from the Standard Model of electroweak interactions. All results are found to be consistent with the Standard Model. The indirect constraint on the top quark mass from all measurements is in excellent agreement with the direct m t measurements. Using the world's electroweak data in conjunction with the current measurement of the top quark mass, the constraints on the Higgs' mass are discussed

  4. Electroweak precision tests

    International Nuclear Information System (INIS)

    Monteil, St.

    2009-12-01

    This document aims at summarizing a dozen of years of the author's research in High Energy Physics, in particular dealing with precision tests of the electroweak theory. Parity violating asymmetries measurements at LEP with the ALEPH detector together with global consistency checks of the Kobayashi-Maskawa paradigm within the CKM-fitter group are gathered in the first part of the document. The second part deals with the unpublished instrumental work about the design, tests, productions and commissioning of the elements of the Pre-Shower detector of the LHCb spectrometer at LHC. Physics perspectives with LHCb are eventually discussed as a conclusion. (author)

  5. Ultra-precision bearings

    CERN Document Server

    Wardle, F

    2015-01-01

    Ultra-precision bearings can achieve extreme accuracy of rotation, making them ideal for use in numerous applications across a variety of fields, including hard disk drives, roundness measuring machines and optical scanners. Ultraprecision Bearings provides a detailed review of the different types of bearing and their properties, as well as an analysis of the factors that influence motion error, stiffness and damping. Following an introduction to basic principles of motion error, each chapter of the book is then devoted to the basic principles and properties of a specific type of bearin

  6. Implementing and Characterizing Precise Multiqubit Measurements

    Directory of Open Access Journals (Sweden)

    J. Z. Blumoff

    2016-09-01

    Full Text Available There are two general requirements to harness the computational power of quantum mechanics: the ability to manipulate the evolution of an isolated system and the ability to faithfully extract information from it. Quantum error correction and simulation often make a more exacting demand: the ability to perform nondestructive measurements of specific correlations within that system. We realize such measurements by employing a protocol adapted from Nigg and Girvin [Phys. Rev. Lett. 110, 243604 (2013], enabling real-time selection of arbitrary register-wide Pauli operators. Our implementation consists of a simple circuit quantum electrodynamics module of four highly coherent 3D transmon qubits, collectively coupled to a high-Q superconducting microwave cavity. As a demonstration, we enact all seven nontrivial subset-parity measurements on our three-qubit register. For each, we fully characterize the realized measurement by analyzing the detector (observable operators via quantum detector tomography and by analyzing the quantum backaction via conditioned process tomography. No single quantity completely encapsulates the performance of a measurement, and standard figures of merit have not yet emerged. Accordingly, we consider several new fidelity measures for both the detector and the complete measurement process. We measure all of these quantities and report high fidelities, indicating that we are measuring the desired quantities precisely and that the measurements are highly nondemolition. We further show that both results are improved significantly by an additional error-heralding measurement. The analyses we present here form a useful basis for the future characterization and validation of quantum measurements, anticipating the demands of emerging quantum technologies.

  7. A Methodology for Validating Safety Heuristics Using Clinical Simulations: Identifying and Preventing Possible Technology-Induced Errors Related to Using Health Information Systems

    Science.gov (United States)

    Borycki, Elizabeth; Kushniruk, Andre; Carvalho, Christopher

    2013-01-01

    Internationally, health information systems (HIS) safety has emerged as a significant concern for governments. Recently, research has emerged that has documented the ability of HIS to be implicated in the harm and death of patients. Researchers have attempted to develop methods that can be used to prevent or reduce technology-induced errors. Some researchers are developing methods that can be employed prior to systems release. These methods include the development of safety heuristics and clinical simulations. In this paper, we outline our methodology for developing safety heuristics specific to identifying the features or functions of a HIS user interface design that may lead to technology-induced errors. We follow this with a description of a methodological approach to validate these heuristics using clinical simulations. PMID:23606902

  8. Principles of precision medicine in stroke.

    Science.gov (United States)

    Hinman, Jason D; Rost, Natalia S; Leung, Thomas W; Montaner, Joan; Muir, Keith W; Brown, Scott; Arenillas, Juan F; Feldmann, Edward; Liebeskind, David S

    2017-01-01

    The era of precision medicine has arrived and conveys tremendous potential, particularly for stroke neurology. The diagnosis of stroke, its underlying aetiology, theranostic strategies, recurrence risk and path to recovery are populated by a series of highly individualised questions. Moreover, the phenotypic complexity of a clinical diagnosis of stroke makes a simple genetic risk assessment only partially informative on an individual basis. The guiding principles of precision medicine in stroke underscore the need to identify, value, organise and analyse the multitude of variables obtained from each individual to generate a precise approach to optimise cerebrovascular health. Existing data may be leveraged with novel technologies, informatics and practical clinical paradigms to apply these principles in stroke and realise the promise of precision medicine. Importantly, precision medicine in stroke will only be realised once efforts to collect, value and synthesise the wealth of data collected in clinical trials and routine care starts. Stroke theranostics, the ultimate vision of synchronising tailored therapeutic strategies based on specific diagnostic data, demand cerebrovascular expertise on big data approaches to clinically relevant paradigms. This review considers such challenges and delineates the principles on a roadmap for rational application of precision medicine to stroke and cerebrovascular health. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Environmental Testing for Precision Parts and Instruments

    International Nuclear Information System (INIS)

    Choi, Man Yong; Park, Jeong Hak; Yun, Kyu Tek

    2001-01-01

    Precision parts and instruments are tested to evaluate performance in development-process and product-step to prement a potential defect due to a failure design. In this paper, Environmental test technology, which is the basis of reliability analysis, is introduced with examples of test criterion, test method for products, encoder and traffic signal controller, and measuring instruments. Recently, as the importance of the environmental test technology is recognised. It is proposed that training of test technician and technology of jig design and failure analysis are very essential

  10. Precision lifetime measurements

    International Nuclear Information System (INIS)

    Tanner, C.E.

    1994-01-01

    Precision measurements of atomic lifetimes provide important information necessary for testing atomic theory. The authors employ resonant laser excitation of a fast atomic beam to measure excited state lifetimes by observing the decay-in-flight of the emitted fluorescence. A similar technique was used by Gaupp, et al., who reported measurements with precisions of less than 0.2%. Their program includes lifetime measurements of the low lying p states in alkali and alkali like systems. Motivation for this work comes from a need to test the atomic many-body-perturbation theory (MBPT) that is necessary for interpretation of parity nonconservation experiments in atomic cesium. The authors have measured the cesium 6p 2 P 1/2 and 6p 2 P 3/2 state lifetimes to be 34.934±0.094 ns and 30.499±0.070 ns respectively. With minor changes to the apparatus, they have extended their measurements to include the lithium 2p 2 P 1/2 and 2p 2 P 3/2 states

  11. Precision measurements in supersymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Johnathan Lee [Stanford Univ., CA (United States)

    1995-05-01

    Supersymmetry is a promising framework in which to explore extensions of the standard model. If candidates for supersymmetric particles are found, precision measurements of their properties will then be of paramount importance. The prospects for such measurements and their implications are the subject of this thesis. If charginos are produced at the LEP II collider, they are likely to be one of the few available supersymmetric signals for many years. The author considers the possibility of determining fundamental supersymmetry parameters in such a scenario. The study is complicated by the dependence of observables on a large number of these parameters. He proposes a straightforward procedure for disentangling these dependences and demonstrate its effectiveness by presenting a number of case studies at representative points in parameter space. In addition to determining the properties of supersymmetric particles, precision measurements may also be used to establish that newly-discovered particles are, in fact, supersymmetric. Supersymmetry predicts quantitative relations among the couplings and masses of superparticles. The author discusses tests of such relations at a future e{sup +}e{sup {minus}} linear collider, using measurements that exploit the availability of polarizable beams. Stringent tests of supersymmetry from chargino production are demonstrated in two representative cases, and fermion and neutralino processes are also discussed.

  12. Precision muon physics

    Science.gov (United States)

    Gorringe, T. P.; Hertzog, D. W.

    2015-09-01

    The muon is playing a unique role in sub-atomic physics. Studies of muon decay both determine the overall strength and establish the chiral structure of weak interactions, as well as setting extraordinary limits on charged-lepton-flavor-violating processes. Measurements of the muon's anomalous magnetic moment offer singular sensitivity to the completeness of the standard model and the predictions of many speculative theories. Spectroscopy of muonium and muonic atoms gives unmatched determinations of fundamental quantities including the magnetic moment ratio μμ /μp, lepton mass ratio mμ /me, and proton charge radius rp. Also, muon capture experiments are exploring elusive features of weak interactions involving nucleons and nuclei. We will review the experimental landscape of contemporary high-precision and high-sensitivity experiments with muons. One focus is the novel methods and ingenious techniques that achieve such precision and sensitivity in recent, present, and planned experiments. Another focus is the uncommonly broad and topical range of questions in atomic, nuclear and particle physics that such experiments explore.

  13. Validation of the high-throughput marker technology DArT using the model plant Arabidopsis thaliana

    NARCIS (Netherlands)

    Wittenberg, A.H.J.; Lee, van der T.A.J.; Cayla, C.; Kilian, A.; Visser, R.G.F.; Schouten, H.J.

    2005-01-01

    Diversity Arrays Technology (DArT) is a microarray-based DNA marker technique for genome-wide discovery and genotyping of genetic variation. DArT allows simultaneous scoring of hundreds of restriction site based polymorphisms between genotypes and does not require DNA sequence information or

  14. Towards the Acceptance of RSS to Support Learning: An Empirical Study to Validate the Technology Acceptance Model in Lebanon

    Science.gov (United States)

    Tarhini, Ali; Hassouna, Mohammad; Abbasi, Muhammad Sharif; Orozco, Jorge

    2015-01-01

    Simpler is better. There are a lot of "needs" in e-Learning, and there's often a limit to the time, talent, and money that can be thrown at them individually. Contemporary pedagogy in technology and engineering disciplines, within the higher education context, champion instructional designs that emphasize peer instruction and rich…

  15. Valid Issues but Limited Scope: A Response to Kitchen and Berk's Research Commentary on Educational Technology

    Science.gov (United States)

    Clements, Douglas H.; Sarama, Julie

    2017-01-01

    In their Research Commentary, Kitchen and Berk (2016) argue that educational technology may focus only on skills for low-income students and students of color, further limiting their opportunities to learn mathematical reasoning, and thus pose a challenge to realizing standards-based reforms. Although we share the concern about equity and about…

  16. DTU PMU Laboratory Development - Testing and Validation

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE...... standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to follow known patterns and provide confirmation about the test system to confirm the design and settings....... In a nutshell, having 2 PMUs that observe same signals provides validation of the operation and flags questionable results with more certainty. Moreover, the performance and accuracy of the DTU-PMU is tested acquiring good and precise results, when compared with a commercial phasor measurement device, PMU-1....

  17. Development and validation of a multiplex add-on assay for sepsis biomarkers using xMAP technology

    DEFF Research Database (Denmark)

    Kofoed, Kristian; Schneider, Uffe Vest; Scheel, Troels

    2006-01-01

    BACKGROUND: Sepsis is a common and often fatal disease. Because sepsis can be caused by many different organisms, biomarkers that can aid in diagnosing sepsis and monitoring treatment efficacy are highly warranted. New sepsis markers may provide additional information to complement the currently...... triggering receptor expressed on myeloid cells-1 (sTREM-1), and macrophage migration inhibiting factor (MIF) was developed and validated in-house. This 3-plex assay was added to a commercially available interleukin-1beta (IL-1beta), IL-6, IL-8, granulocyte/macrophage colony-stimulating factor, and tumor...

  18. Development and validation of a multiplex add-on assay of biomarkers related to sepsis using xMAP technology

    DEFF Research Database (Denmark)

    Kofoed, Kristian; Vest Schneider, Uffe; Scheel, Troels

    2006-01-01

    BACKGROUND: Sepsis is a common and often fatal disease. Because sepsis can be caused by many different organisms, biomarkers that can aid in diagnosing sepsis and monitoring treatment efficacy are highly warranted. New sepsis markers may provide additional information to complement the currently...... triggering receptor expressed on myeloid cells-1 (sTREM-1), and macrophage migration inhibiting factor (MIF) was developed and validated in-house. This 3-plex assay was added to a commercially available interleukin-1beta (IL-1beta), IL-6, IL-8, granulocyte/macrophage colony-stimulating factor, and tumor...

  19. Importance of the validation of saving technologies of electric power; Importancia de la validacion de tecnologias ahorradoras de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valer Negrete, Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad (Mexico)

    2003-07-01

    Within the Programs of Energy Saving it is fundamental the search and application of new technologies, with which this saving can be obtained, selected with base in their technical characteristics that allow to reduce to the consumptions and demands of power, without damaging the electric networks nor the transformers of the Comision Federal de Electricidad. It is important that the investments which are made count on attractive periods of capital recovery, in comparison with the useful life of the product, reason why the knowledge and price of the new technologies will be parameters to consider in an important manner, creating the need of conducting tests that verify the veracity of the information of the supplier, resulting in certain cases, the change of design of these technologies, so that thus they fulfill the engaged characteristics. This paper indicates the characteristics that the new saving technologies of electrical energy must fulfill and the tests and parameters to consider their evaluation. [Spanish] Dentro de los Programas de Ahorro de Energia es fundamental la busqueda y aplicacion de nuevas tecnologias, con las que se pueda obtener dicho ahorro, seleccionadas con base en sus caracteristicas tecnicas que permitan reducir los consumos y demandas de potencia, sin danar las redes ni transformadores de la Comision Federal de Electricidad. Es importante que las inversiones que se realicen cuenten con periodos de recuperacion de capital atractivos, comparados con la vida util del producto, por lo que el conocimiento y precio de las nuevas tecnologias seran parametros a considerar de manera importante, creandose la necesidad de realizar pruebas que verifiquen la veracidad de la informacion del proveedor, resultando en determinados casos, el cambio de diseno de dichas tecnologias, para que asi cumplan las caracteristicas prometidas. Este trabajo indica las caracteristicas que deben cumplir las nuevas tecnologias ahorradoras de energia electrica y las

  20. AMCP Partnership Forum: Managing Care in the Wave of Precision Medicine.

    Science.gov (United States)

    2018-05-23

    Precision medicine, the customization of health care to an individual's genetic profile while accounting for biomarkers and lifestyle, has increasingly been adopted by health care stakeholders to guide the development of treatment options, improve treatment decision making, provide more patient-centered care, and better inform coverage and reimbursement decisions. Despite these benefits, key challenges prevent its broader use and adoption. On December 7-8, 2017, the Academy of Managed Care Pharmacy convened a group of stakeholders to discuss these challenges and provide recommendations to facilitate broader adoption and use of precision medicine across health care settings. These stakeholders represented the pharmaceutical industry, clinicians, patient advocacy, private payers, device manufacturers, health analytics, information technology, academia, and government agencies. Throughout the 2-day forum, participants discussed evidence requirements for precision medicine, including consistent ways to measure the utility and validity of precision medicine tests and therapies, limitations of traditional clinical trial designs, and limitations of value assessment framework methods. They also highlighted the challenges with evidence collection and data silos in precision medicine. Interoperability within and across health systems is hindering clinical advancements. Current medical coding systems also cannot account for the heterogeneity of many diseases, preventing health systems from having a complete understanding of their patient population to inform resource allocation. Challenges faced by payers, such as evidence limitations, to inform coverage and reimbursement decisions in precision medicine, as well as legal and regulatory barriers that inhibit more widespread data sharing, were also identified. While a broad range of perspectives was shared throughout the forum, participants reached consensus across 2 overarching areas. First, there is a greater need for common

  1. Precision Medicine in Cancer Treatment

    Science.gov (United States)

    Precision medicine helps doctors select cancer treatments that are most likely to help patients based on a genetic understanding of their disease. Learn about the promise of precision medicine and the role it plays in cancer treatment.

  2. Technology.

    Science.gov (United States)

    Online-Offline, 1998

    1998-01-01

    Focuses on technology, on advances in such areas as aeronautics, electronics, physics, the space sciences, as well as computers and the attendant progress in medicine, robotics, and artificial intelligence. Describes educational resources for elementary and middle school students, including Web sites, CD-ROMs and software, videotapes, books,…

  3. The development of advanced instrumentation and control technology. The development of verification and validation technology for instrumentation and control in NPPs

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Ham, Chang Shik; Lee, Jang Soo; Kim, Jang Yeol; Song, Soon Ja; Kim, Jung Taek; Park, Won Man; Lee, Dong Young; Eom, Heung Seop; Park, Kee Yong.

    1997-07-01

    We found essential problems followed by digitalizing of instrumentation and control. A scheme is divided into hardware and software to resolve these problems. We have analyzed the hardware V and V methodologies about common mode failure, commercial grade dedication process and electromagnetic compatibility. We have developed several guidelines, the software classification guideline, the quality assurance handbook for the software in digital I and C, the software V and V planning guideline, and the software safety guideline. And then, we have established the integrated environment for the safety-critical software based on the Computer Aided Software Engineering (CASE) tools. We have also surveyed a trend and application case of test facility for establishment of functional requirements. Input/output interface which connects among the host computer and developed target and panel are designed and manufactured using UXI bus. The developed functional test facility is used for test and validate the automatic start-up intelligent control system, the dynamic alarm system, the accident identification system using hidden Markov model, and the intelligent logic tracking system. The result of evaluation of the above systems shows the functional test facility performance is sufficient in normal operating and transient conditions. (author). 24 tabs., 59 figs

  4. The development of advanced instrumentation and control technology. The development of verification and validation technology for instrumentation and control in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Ham, Chang Shik; Lee, Jang Soo; Kim, Jang Yeol; Song, Soon Ja; Kim, Jung Taek; Park, Won Man; Lee, Dong Young; Eom, Heung Seop; Park, Kee Yong

    1997-07-01

    We found essential problems followed by digitalizing of instrumentation and control. A scheme is divided into hardware and software to resolve these problems. We have analyzed the hardware V and V methodologies about common mode failure, commercial grade dedication process and electromagnetic compatibility. We have developed several guidelines, the software classification guideline, the quality assurance handbook for the software in digital I and C, the software V and V planning guideline, and the software safety guideline. And then, we have established the integrated environment for the safety-critical software based on the Computer Aided Software Engineering (CASE) tools. We have also surveyed a trend and application case of test facility for establishment of functional requirements. Input/output interface which connects among the host computer and developed target and panel are designed and manufactured using UXI bus. The developed functional test facility is used for test and validate the automatic start-up intelligent control system, the dynamic alarm system, the accident identification system using hidden Markov model, and the intelligent logic tracking system. The result of evaluation of the above systems shows the functional test facility performance is sufficient in normal operating and transient conditions. (author). 24 tabs., 59 figs.

  5. Validation of Advanced Computer Codes for VVER Technology: LB-LOCA Transient in PSB-VVER Facility

    Directory of Open Access Journals (Sweden)

    A. Del Nevo

    2012-01-01

    Full Text Available The OECD/NEA PSB-VVER project provided unique and useful experimental data for code validation from PSB-VVER test facility. This facility represents the scaled-down layout of the Russian-designed pressurized water reactor, namely, VVER-1000. Five experiments were executed, dealing with loss of coolant scenarios (small, intermediate, and large break loss of coolant accidents, a primary-to-secondary leak, and a parametric study (natural circulation test aimed at characterizing the VVER system at reduced mass inventory conditions. The comparative analysis, presented in the paper, regards the large break loss of coolant accident experiment. Four participants from three different institutions were involved in the benchmark and applied their own models and set up for four different thermal-hydraulic system codes. The benchmark demonstrated the performances of such codes in predicting phenomena relevant for safety on the basis of fixed criteria.

  6. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP.

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,.

  7. Precision Medicine in Cardiovascular Diseases

    Directory of Open Access Journals (Sweden)

    Yan Liu

    2017-02-01

    Full Text Available Since President Obama announced the Precision Medicine Initiative in the United States, more and more attention has been paid to precision medicine. However, clinicians have already used it to treat conditions such as cancer. Many cardiovascular diseases have a familial presentation, and genetic variants are associated with the prevention, diagnosis, and treatment of cardiovascular diseases, which are the basis for providing precise care to patients with cardiovascular diseases. Large-scale cohorts and multiomics are critical components of precision medicine. Here we summarize the application of precision medicine to cardiovascular diseases based on cohort and omic studies, and hope to elicit discussion about future health care.

  8. PRODUCTIVE PROGRESS IN A GOAT PRODUCERS ASSOCIATION, "CAPRINOCULTORES UNIDOS DE GUANAJUATO AC", THROUGH A TECHNOLOGY TRANSFER SYSTEM GGAVATT (LIVESTOCK VALIDATION AND TECHNOLOGY TRANSFER GROUP (2001-2007

    Directory of Open Access Journals (Sweden)

    Jose Oliveros-Oliveros

    2009-02-01

    Full Text Available The aim of the study was to analyze the effect of technology adoption on milk goat producers in central México. The association has 13 producers, with an average age 41.5 years old, the average schooling reaches junior high school (3rd year, and  a mean of 6 dependants per family. This association has an average number of 246 female goats per herd, a total of 3447 females, and 2190 females in production control. The income in relation to investment is 36%. Technological practices implemented to date and the percentage of use are: Weighing milk (100%, Animal Nutrition consulting (71%, Estrus synchronization and reproductive management techniques (40%, Gestation Diagnosis (93%, Brucellosis control herd program (100%, Artificial kids raising in slat (46%, Disease diagnosis and management (61%, Certification of good milking practice (53%, Linear and genetics evaluation (87% Evaluation of genetic records ( 61%, Forage  conservation by silage (93%, Milk components analysis (100%, dispersion of genetic material (71%, Analysis and data processing for replacement selection and animal sale (Sire and females(100%, Bacteriological analysis of milk (93%, Cryoscopic point of milk (100%, and Diagnosis of subclinical mastitis (cytometryc flow (100%. An 80% of the producers have adopted different practices, and the association has promoted and implemented different programs such as: control milk production, milk quality, genealogical records, disease control, marketing in group, sales of fluid milk and dehydration of milk for conservation and sale. Accordingly to such practices, results are as follows: 11,180 kids born, from which 52% were females and 48% males, with 56.9%, 24.3%, 15.7% and 2.9% of double, triple, simple and quadruple births, respectively. The mean birth weight was 3.32 kg and 15.7 kg weaning at 60 days, with a daily gain weight (DGW of 206.33 g. For milk production, 3534 lactations were analyzed from 1999 to 2007 in a 90.4% of animals

  9. Precision Warfare Enables Interdependent Fires and Maneuver in 2010

    National Research Council Canada - National Science Library

    Smith, John

    1997-01-01

    The U.S. Army is in the midst of a revolution in military affairs (RMA). Significant advancements in informational technologies and precision weapons are providing unprecedented potential for future warfare...

  10. Distributed Control Architectures for Precision Spacecraft Formations, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — LaunchPoint Technologies, Inc. (LaunchPoint) proposes to develop synthesis methods and design architectures for distributed control systems in precision spacecraft...

  11. Precise Quantitative Assessment of the Clinical Performances of Two High-Flux Polysulfone Hemodialyzers in Hemodialysis: Validation of a Blood-Based Simple Kinetic Model Versus Direct Dialysis Quantification.

    Science.gov (United States)

    Lim, Paik-Seong; Lin, Yuyu; Chen, Minfeng; Xu, Xiaoqi; Shi, Yun; Bowry, Sudhir; Canaud, Bernard

    2018-05-01

    Highly permeable dialysis membranes with better design filters have contributed to improved solute removal and dialysis efficacy. However, solute membrane permeability needs to be well controlled to avoid increased loss of albumin that is considered to be detrimental for dialysis patients. A novel high-flux dialyzer type (FX CorDiax; Fresenius Medical Care) incorporating an advanced polysulfone membrane modified with nano-controlled spinning technology to enhance the elimination of a broader spectrum of uremic toxins has been released. The aim of this study was to compare in the clinical setting two dialyzer types having the same surface area, the current (FX dialyzer) and the new dialyzer generation (FX CorDiax), with respect to solute removal capacity over a broad spectrum of markers, including assessment of albumin loss based on a direct dialysis quantification method. We performed a crossover study following an A1-B-A2 design involving 10 patients. Phase A1 was 1 week of thrice-weekly bicarbonate hemodialysis with the FX dialyzer, 4 h per treatment; phase B was performed with a similar treatment regimen but with a new FX CorDiax dialyzer and finally the phase A2 was repeated with FX dialyzer as the former phase. Solute removal markers of interest were assessed from blood samples taken before and after treatment and from total spent dialysate collection (direct dialysis quantification) permitting a mass transfer calculation (mg/session into total spent dialysate/ultrafiltrate). On the blood side, there were no significant differences in the solute percent reduction between FX CorDiax 80 and FX 80. On the dialysate side, no difference was observed regarding eliminated mass of different solutes including β 2 -microglobulin (143.1 ± 33.6 vs. 138.3 ± 41.9 mg, P = 0.8), while the solute mass removal of total protein (1.65 ± 0.51 vs. 2.14 ± 0.75 g, P = 0.04), and albumin (0.41 ± 0.21 vs. 1.22 ± 0.51 g, P < 0.001) were

  12. FY 1998 report on the results of the R and D for acceleration of biological resource information basement preparation (bioinformatics). Third revision. Development of measurement technology of interaction among biological molecules (Development of high-precise automatic analysis technology for a trace amount of cellular protein); 1998 nendo seibutsu shigen joho kiban seibi kasokuka kenkyu kaihatsu (bioinformatics) seika hokokusho. Seitai bunshikan sogo sayo no keisoku gijutsu no kaihatsu (saibonai chobiryo tanpakushitsu no koseido jido kaiseki gijutsu no kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    An experimental study was conducted with the aim of developing the technology to acquire/analyze in high sensitivity manifestation proteins existing in a trace amount and in various kinds, concretely, signal transfer molecules, transcription factors, etc. which exist in one cell. After extracting a trace amount of functional proteins for analysis from the specified functional cell, the study was made on the following: precise separation and detection technique for cellular proteins, efficient digestion technique and contaminant elimination technique of stained protein, precise separation of peptides by micro-LC technique, precise peptide molecular mass detection of each separated peptide with high sensitivity, reconstruction of protein structure by computer algorithm. As a result, as to the analysis level, an analysis technology with high sensitivity of a 50 fmol level was established as against the existing level of several pmol. Moreover, after the separation/digestion of proteins by the 2D electrophoresis, a series of the process automation system was completed which is high-precise separation using protein columns - molecular analysis - structure prediction by computer. (NEDO)

  13. Precisely predictable Dirac observables

    CERN Document Server

    Cordes, Heinz Otto

    2006-01-01

    This work presents a "Clean Quantum Theory of the Electron", based on Dirac’s equation. "Clean" in the sense of a complete mathematical explanation of the well known paradoxes of Dirac’s theory, and a connection to classical theory, including the motion of a magnetic moment (spin) in the given field, all for a charged particle (of spin ½) moving in a given electromagnetic field. This theory is relativistically covariant, and it may be regarded as a mathematically consistent quantum-mechanical generalization of the classical motion of such a particle, à la Newton and Einstein. Normally, our fields are time-independent, but also discussed is the time-dependent case, where slightly different features prevail. A "Schroedinger particle", such as a light quantum, experiences a very different (time-dependent) "Precise Predictablity of Observables". An attempt is made to compare both cases. There is not the Heisenberg uncertainty of location and momentum; rather, location alone possesses a built-in uncertainty ...

  14. Precisely Tracking Childhood Death.

    Science.gov (United States)

    Farag, Tamer H; Koplan, Jeffrey P; Breiman, Robert F; Madhi, Shabir A; Heaton, Penny M; Mundel, Trevor; Ordi, Jaume; Bassat, Quique; Menendez, Clara; Dowell, Scott F

    2017-07-01

    Little is known about the specific causes of neonatal and under-five childhood death in high-mortality geographic regions due to a lack of primary data and dependence on inaccurate tools, such as verbal autopsy. To meet the ambitious new Sustainable Development Goal 3.2 to eliminate preventable child mortality in every country, better approaches are needed to precisely determine specific causes of death so that prevention and treatment interventions can be strengthened and focused. Minimally invasive tissue sampling (MITS) is a technique that uses needle-based postmortem sampling, followed by advanced histopathology and microbiology to definitely determine cause of death. The Bill & Melinda Gates Foundation is supporting a new surveillance system called the Child Health and Mortality Prevention Surveillance network, which will determine cause of death using MITS in combination with other information, and yield cause-specific population-based mortality rates, eventually in up to 12-15 sites in sub-Saharan Africa and south Asia. However, the Gates Foundation funding alone is not enough. We call on governments, other funders, and international stakeholders to expand the use of pathology-based cause of death determination to provide the information needed to end preventable childhood mortality.

  15. Development of a tool dedicated to the evaluation of hydrogen term source for technological Wastes: assumptions, physical models, and validation

    Energy Technology Data Exchange (ETDEWEB)

    Lamouroux, C. [CEA Saclay, Nuclear Energy Division /DANS, Department of physico-chemistry, 91191 Gif sur yvette (France); Esnouf, S. [CEA Saclay, DSM/IRAMIS/SIS2M/Radiolysis Laboratory , 91191 Gif sur yvette (France); Cochin, F. [Areva NC,recycling BU, DIRP/RDP tour Areva, 92084 Paris La Defense (France)

    2013-07-01

    In radioactive waste packages hydrogen is generated, in one hand, from the radiolysis of wastes (mainly organic materials) and, in the other hand, from the radiolysis of water content in the cement matrix. In order to assess hydrogen generation 2 tools based on operational models have been developed. One is dedicated to the determination of the hydrogen source term issues from the radiolysis of the wastes: the STORAGE tool (Simulation Tool Of Emission Radiolysis Gas), the other deals with the hydrogen source term gas, produced by radiolysis of the cement matrices (the Damar tool). The approach used by the STORAGE tool for assessing the production rate of radiolysis gases is divided into five steps: 1) Specification of the data packages, in particular, inventories and radiological materials defined for a package medium; 2) Determination of radiochemical yields for the different constituents and the laws of behavior associated, this determination of radiochemical yields is made from the PRELOG database in which radiochemical yields in different irradiation conditions have been compiled; 3) Definition of hypothesis concerning the composition and the distribution of contamination inside the package to allow assessment of the power absorbed by the constituents; 4) Sum-up of all the contributions; And finally, 5) validation calculations by comparison with a reduced sampling of packages. Comparisons with measured values confirm the conservative character of the methodology and give confidence in the safety margins for safety analysis report.

  16. Characterization of a Reconfigurable Free-Space Optical Channel for Embedded Computer Applications with Experimental Validation Using Rapid Prototyping Technology

    Directory of Open Access Journals (Sweden)

    Rafael Gil-Otero

    2007-02-01

    Full Text Available Free-space optical interconnects (FSOIs are widely seen as a potential solution to current and future bandwidth bottlenecks for parallel processors. In this paper, an FSOI system called optical highway (OH is proposed. The OH uses polarizing beam splitter-liquid crystal plate (PBS/LC assemblies to perform reconfigurable beam combination functions. The properties of the OH make it suitable for embedding complex network topologies such as completed connected mesh or hypercube. This paper proposes the use of rapid prototyping technology for implementing an optomechanical system suitable for studying the reconfigurable characteristics of a free-space optical channel. Additionally, it reports how the limited contrast ratio of the optical components can affect the attenuation of the optical signal and the crosstalk caused by misdirected signals. Different techniques are also proposed in order to increase the optical modulation amplitude (OMA of the system.

  17. Characterization of a Reconfigurable Free-Space Optical Channel for Embedded Computer Applications with Experimental Validation Using Rapid Prototyping Technology

    Directory of Open Access Journals (Sweden)

    Lim Theodore

    2007-01-01

    Full Text Available Free-space optical interconnects (FSOIs are widely seen as a potential solution to current and future bandwidth bottlenecks for parallel processors. In this paper, an FSOI system called optical highway (OH is proposed. The OH uses polarizing beam splitter-liquid crystal plate (PBS/LC assemblies to perform reconfigurable beam combination functions. The properties of the OH make it suitable for embedding complex network topologies such as completed connected mesh or hypercube. This paper proposes the use of rapid prototyping technology for implementing an optomechanical system suitable for studying the reconfigurable characteristics of a free-space optical channel. Additionally, it reports how the limited contrast ratio of the optical components can affect the attenuation of the optical signal and the crosstalk caused by misdirected signals. Different techniques are also proposed in order to increase the optical modulation amplitude (OMA of the system.

  18. Technology

    Directory of Open Access Journals (Sweden)

    Xu Jing

    2016-01-01

    Full Text Available The traditional answer card reading method using OMR (Optical Mark Reader, most commonly, OMR special card special use, less versatile, high cost, aiming at the existing problems proposed a method based on pattern recognition of the answer card identification method. Using the method based on Line Segment Detector to detect the tilt of the image, the existence of tilt image rotation correction, and eventually achieve positioning and detection of answers to the answer sheet .Pattern recognition technology for automatic reading, high accuracy, detect faster

  19. Psychometric properties of the 25-item Work Limitations Questionnaire in Japan: factor structure, validity, and reliability in information and communication technology company employees.

    Science.gov (United States)

    Kono, Yuko; Matsushima, Eisuke; Uji, Masayo

    2014-02-01

    The 25-item Work Limitations Questionnaire (WLQ-25) measures presenteeism but has not been sufficiently validated in a Japanese population. A total of 451 employees from four information technology companies in Tokyo completed the WLQ-25 and questionnaires of other variables on two occasions, 2 weeks apart. The WLQ-25 yielded a two-factor structure: Cognitive Demand and Physical Demand. These subscales showed good internal consistency, and both were associated with adverse working conditions, greater perceived job strain, lower skill use, poorer workplace social support, and less satisfactory psychological adjustment. Intraclass correlation coefficients of the two WLQ-25 subscales between time 1 and time 2 were 0.78 and 0.55, respectively. This study suggests acceptable psychometric properties of the WLQ-25 in Japan.

  20. Precise Truss Assembly Using Commodity Parts and Low Precision Welding

    Science.gov (United States)

    Komendera, Erik; Reishus, Dustin; Dorsey, John T.; Doggett, W. R.; Correll, Nikolaus

    2014-01-01

    Hardware and software design and system integration for an intelligent precision jigging robot (IPJR), which allows high precision assembly using commodity parts and low-precision bonding, is described. Preliminary 2D experiments that are motivated by the problem of assembling space telescope optical benches and very large manipulators on orbit using inexpensive, stock hardware and low-precision welding are also described. An IPJR is a robot that acts as the precise "jigging", holding parts of a local structure assembly site in place, while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (for this prototype, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. The analysis of the assembly error and the results of building a square structure and a ring structure are discussed. Options for future work, to extend the IPJR paradigm to building in 3D structures at micron precision are also summarized.

  1. [Precision nutrition in the era of precision medicine].

    Science.gov (United States)

    Chen, P Z; Wang, H

    2016-12-06

    Precision medicine has been increasingly incorporated into clinical practice and is enabling a new era for disease prevention and treatment. As an important constituent of precision medicine, precision nutrition has also been drawing more attention during physical examinations. The main aim of precision nutrition is to provide safe and efficient intervention methods for disease treatment and management, through fully considering the genetics, lifestyle (dietary, exercise and lifestyle choices), metabolic status, gut microbiota and physiological status (nutrient level and disease status) of individuals. Three major components should be considered in precision nutrition, including individual criteria for sufficient nutritional status, biomarker monitoring or techniques for nutrient detection and the applicable therapeutic or intervention methods. It was suggested that, in clinical practice, many inherited and chronic metabolic diseases might be prevented or managed through precision nutritional intervention. For generally healthy populations, because lifestyles, dietary factors, genetic factors and environmental exposures vary among individuals, precision nutrition is warranted to improve their physical activity and reduce disease risks. In summary, research and practice is leading toward precision nutrition becoming an integral constituent of clinical nutrition and disease prevention in the era of precision medicine.

  2. Precision medicine in myasthenia graves: begin from the data precision

    Science.gov (United States)

    Hong, Yu; Xie, Yanchen; Hao, Hong-Jun; Sun, Ren-Cheng

    2016-01-01

    Myasthenia gravis (MG) is a prototypic autoimmune disease with overt clinical and immunological heterogeneity. The data of MG is far from individually precise now, partially due to the rarity and heterogeneity of this disease. In this review, we provide the basic insights of MG data precision, including onset age, presenting symptoms, generalization, thymus status, pathogenic autoantibodies, muscle involvement, severity and response to treatment based on references and our previous studies. Subgroups and quantitative traits of MG are discussed in the sense of data precision. The role of disease registries and scientific bases of precise analysis are also discussed to ensure better collection and analysis of MG data. PMID:27127759

  3. A cross-cultural validation of the Technology-Rich Outcomes-Focused Learning Environment Inventory (TROFLEI) in Turkey and the USA

    Science.gov (United States)

    Welch, Anita G.; Cakir, Mustafa; Peterson, Claudette M.; Ray, Chris M.

    2012-04-01

    Background . Studies exploring the relationship between students' achievement and the quality of the classroom learning environments have shown that there is a strong relationship between these two concepts. Learning environment instruments are constantly being revised and updated, including for use in different cultures, which requires continued validation efforts. Purpose The purpose of this study was to establish cross-cultural reliability and validity of the Technology-Rich Outcomes-Focused Learning Environment Inventory (TROFLEI) in both Turkey and the USA. Sample Approximately 980 students attending grades 9-12 in Turkey and 130 students attending grades 9-12 in the USA participated in the study. Design and method Scale reliability analyses and confirmatory factor analysis (CFA) were performed separately for Turkish and US participants for both actual and preferred responses to each scale to confirm the structure of the TROFLEI across these two distinct samples. Results Cronbach's alpha reliability coefficients, ranging from α = 0.820 to 0.931 for Turkish participants and from α = 0.778 to 0.939 for US participants, indicated that all scales have satisfactory internal consistency for both samples. Confirmatory factor analyses resulted in evidence of adequate model fit across both samples for both actual and preferred responses, with the root mean square error of approximation ranging from 0.052 to 0.057 and the comparative fit index ranging from 0.920 to 0.982. Conclusions This study provides initial evidence that the TROFLEI is valid for use in both the Turkish and US high-school populations (grades 9-12). However, the psychometric properties should be examined further with different populations, such as middle-school students (grades 6-8).

  4. TBM/MTM for HTS-FNSF: An Innovative Testing Strategy to Qualify/Validate Fusion Technologies for U.S. DEMO

    Directory of Open Access Journals (Sweden)

    Laila El-Guebaly

    2016-08-01

    Full Text Available The qualification and validation of nuclear technologies are daunting tasks for fusion demonstration (DEMO and power plants. This is particularly true for advanced designs that involve harsh radiation environment with 14 MeV neutrons and high-temperature operating regimes. This paper outlines the unique qualification and validation processes developed in the U.S., offering the only access to the complete fusion environment, focusing on the most prominent U.S. blanket concept (the dual cooled PbLi (DCLL along with testing new generations of structural and functional materials in dedicated test modules. The venue for such activities is the proposed Fusion Nuclear Science Facility (FNSF, which is viewed as an essential element of the U.S. fusion roadmap. A staged blanket testing strategy has been developed to test and enhance the DCLL blanket performance during each phase of FNSF D-T operation. A materials testing module (MTM is critically important to include in the FNSF as well to test a broad range of specimens of future, more advanced generations of materials in a relevant fusion environment. The most important attributes for MTM are the relevant He/dpa ratio (10–15 and the much larger specimen volumes compared to the 10–500 mL range available in the International Fusion Materials Irradiation Facility (IFMIF and European DEMO-Oriented Neutron Source (DONES.

  5. Validation of a method for real time foot position and orientation tracking with Microsoft Kinect technology for use in virtual reality and treadmill based gait training programs.

    Science.gov (United States)

    Paolini, Gabriele; Peruzzi, Agnese; Mirelman, Anat; Cereatti, Andrea; Gaukrodger, Stephen; Hausdorff, Jeffrey M; Della Croce, Ugo

    2014-09-01

    The use of virtual reality for the provision of motor-cognitive gait training has been shown to be effective for a variety of patient populations. The interaction between the user and the virtual environment is achieved by tracking the motion of the body parts and replicating it in the virtual environment in real time. In this paper, we present the validation of a novel method for tracking foot position and orientation in real time, based on the Microsoft Kinect technology, to be used for gait training combined with virtual reality. The validation of the motion tracking method was performed by comparing the tracking performance of the new system against a stereo-photogrammetric system used as gold standard. Foot position errors were in the order of a few millimeters (average RMSD from 4.9 to 12.1 mm in the medio-lateral and vertical directions, from 19.4 to 26.5 mm in the anterior-posterior direction); the foot orientation errors were also small (average %RMSD from 5.6% to 8.8% in the medio-lateral and vertical directions, from 15.5% to 18.6% in the anterior-posterior direction). The results suggest that the proposed method can be effectively used to track feet motion in virtual reality and treadmill-based gait training programs.

  6. Improving the precision of noisy oscillators

    Science.gov (United States)

    Moehlis, Jeff

    2014-04-01

    We consider how the period of an oscillator is affected by white noise, with special attention given to the cases of additive noise and parameter fluctuations. Our treatment is based upon the concepts of isochrons, which extend the notion of the phase of a stable periodic orbit to the basin of attraction of the periodic orbit, and phase response curves, which can be used to understand the geometry of isochrons near the periodic orbit. This includes a derivation of the leading-order effect of noise on the statistics of an oscillator’s period. Several examples are considered in detail, which illustrate the use and validity of the theory, and demonstrate how to improve a noisy oscillator’s precision by appropriately tuning system parameters or operating away from a bifurcation point. It is also shown that appropriately timed impulsive kicks can give further improvements to oscillator precision.

  7. Hindrances to acceptation of precision cooking technique in households

    OpenAIRE

    Borremans, Auriane

    2017-01-01

    Master's thesis in International hotel and tourism management: Culinary Leadership and Innovation Many technologies have been created in order to simplify our everyday life and technology in the kitchen is not an exception. Indeed, evolution in the dimension of technology is keeping growing up from the first micro wave to the recent induction cooking hobs. The precision cooking method is also part of these new technologies but have not been adopted by many households yet. In this paper,...

  8. Precision measurements with atom interferometry

    Science.gov (United States)

    Schubert, Christian; Abend, Sven; Schlippert, Dennis; Ertmer, Wolfgang; Rasel, Ernst M.

    2017-04-01

    Interferometry with matter waves enables precise measurements of rotations, accelerations, and differential accelerations [1-5]. This is exploited for determining fundamental constants [2], in fundamental science as e.g. testing the universality of free fall [3], and is applied for gravimetry [4], and gravity gradiometry [2,5]. At the Institut für Quantenoptik in Hannover, different approaches are pursued. A large scale device is designed and currently being set up to investigate the gain in precision for gravimetry, gradiometry, and fundamental tests on large baselines [6]. For field applications, a compact and transportable device is being developed. Its key feature is an atom chip source providing a collimated high flux of atoms which is expected to mitigate systematic uncertainties [7,8]. The atom chip technology and miniaturization benefits from microgravity experiments in the drop tower in Bremen and sounding rocket experiments [8,9] which act as pathfinders for space borne operation [10]. This contribution will report about our recent results. The presented work is supported by the CRC 1227 DQ-mat, the CRC 1128 geo-Q, the RTG 1729, the QUEST-LFS, and by the German Space Agency (DLR) with funds provided by the Federal Ministry of Economic Affairs and Energy (BMWi) due to an enactment of the German Bundestag under Grant No. DLR 50WM1552-1557. [1] P. Berg et al., Phys. Rev. Lett., 114, 063002, 2015; I. Dutta et al., Phys. Rev. Lett., 116, 183003, 2016. [2] J. B. Fixler et al., Science 315, 74 (2007); G. Rosi et al., Nature 510, 518, 2014. [3] D. Schlippert et al., Phys. Rev. Lett., 112, 203002, 2014. [4] A. Peters et al., Nature 400, 849, 1999; A. Louchet-Chauvet et al., New J. Phys. 13, 065026, 2011; C. Freier et al., J. of Phys.: Conf. Series 723, 012050, 2016. [5] J. M. McGuirk et al., Phys. Rev. A 65, 033608, 2002; P. Asenbaum et al., arXiv:1610.03832. [6] J. Hartwig et al., New J. Phys. 17, 035011, 2015. [7] H. Ahlers et al., Phys. Rev. Lett. 116, 173601

  9. Image Biomarkers and Precision Medicine: need for validation

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Alberich-Bayarri, A.; Garcia Castro, F.

    2016-01-01

    Personalized medicine aims to improve the diagnosis, classification and the best treatment for a particular patient. Today, radiologists are challenged to translate new biological discoveries, the different mechanisms of disease and advances in preclinical research, into a clinical reality through patients, images and their associated parameters. In this article we show how digital medical imaging and computational data processing extract numerous quantitative parameters from the obtained images as virtual biopsies. To be implemented in clinical practice, biomarkers should provide useful and relevant information, improving processes diagnostic, therapeutic and monitoring, for the benefit of patients. (Author)

  10. Precision medicine for cancer with next-generation functional diagnostics.

    Science.gov (United States)

    Friedman, Adam A; Letai, Anthony; Fisher, David E; Flaherty, Keith T

    2015-12-01

    Precision medicine is about matching the right drugs to the right patients. Although this approach is technology agnostic, in cancer there is a tendency to make precision medicine synonymous with genomics. However, genome-based cancer therapeutic matching is limited by incomplete biological understanding of the relationship between phenotype and cancer genotype. This limitation can be addressed by functional testing of live patient tumour cells exposed to potential therapies. Recently, several 'next-generation' functional diagnostic technologies have been reported, including novel methods for tumour manipulation, molecularly precise assays of tumour responses and device-based in situ approaches; these address the limitations of the older generation of chemosensitivity tests. The promise of these new technologies suggests a future diagnostic strategy that integrates functional testing with next-generation sequencing and immunoprofiling to precisely match combination therapies to individual cancer patients.

  11. Big Data's Role in Precision Public Health.

    Science.gov (United States)

    Dolley, Shawn

    2018-01-01

    Precision public health is an emerging practice to more granularly predict and understand public health risks and customize treatments for more specific and homogeneous subpopulations, often using new data, technologies, and methods. Big data is one element that has consistently helped to achieve these goals, through its ability to deliver to practitioners a volume and variety of structured or unstructured data not previously possible. Big data has enabled more widespread and specific research and trials of stratifying and segmenting populations at risk for a variety of health problems. Examples of success using big data are surveyed in surveillance and signal detection, predicting future risk, targeted interventions, and understanding disease. Using novel big data or big data approaches has risks that remain to be resolved. The continued growth in volume and variety of available data, decreased costs of data capture, and emerging computational methods mean big data success will likely be a required pillar of precision public health into the future. This review article aims to identify the precision public health use cases where big data has added value, identify classes of value that big data may bring, and outline the risks inherent in using big data in precision public health efforts.

  12. MEASUREMENT AND PRECISION, EXPERIMENTAL VERSION.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    THIS DOCUMENT IS AN EXPERIMENTAL VERSION OF A PROGRAMED TEXT ON MEASUREMENT AND PRECISION. PART I CONTAINS 24 FRAMES DEALING WITH PRECISION AND SIGNIFICANT FIGURES ENCOUNTERED IN VARIOUS MATHEMATICAL COMPUTATIONS AND MEASUREMENTS. PART II BEGINS WITH A BRIEF SECTION ON EXPERIMENTAL DATA, COVERING SUCH POINTS AS (1) ESTABLISHING THE ZERO POINT, (2)…

  13. Using ISS to develop telescope technology

    Science.gov (United States)

    Saenz-Otero, Alvar; Miller, David W.

    2005-08-01

    Future space telescope missions concepts have introduced new technologies such as precision formation flight, optical metrology, and segmented mirrors. These new technologies require demonstration and validation prior to deployment in final missions such as the James Webb Space Telescope, Terrestrial Planet Finder, and Darwin. Ground based demonstrations do not provide the precision necessary to obtain a high level of confidence in the technology; precursor free flyer space missions suffer from the same problems as the final missions. Therefore, this paper proposes the use of the International Space Station as an intermediate research environment where these technologies can be developed, demonstrated, and validated. The ISS provides special resources, such as human presence, communications, power, and a benign atmosphere which directly reduce the major challenges of space technology maturation: risk, complexity, cost, remote operations, and visibility. Successful design of experiments for use aboard the space station, by enabling iterative research and supporting multiple scientists, can further reduce the effects of these challenges of space technology maturation. This paper presents results of five previous MIT Space Systems Laboratory experiments aboard the Space Shuttle, MIR, and the ISS to illustrate successful technology maturation aboard these facilities.

  14. Precision medicine for nurses: 101.

    Science.gov (United States)

    Lemoine, Colleen

    2014-05-01

    To introduce the key concepts and terms associated with precision medicine and support understanding of future developments in the field by providing an overview and history of precision medicine, related ethical considerations, and nursing implications. Current nursing, medical and basic science literature. Rapid progress in understanding the oncogenic drivers associated with cancer is leading to a shift toward precision medicine, where treatment is based on targeting specific genetic and epigenetic alterations associated with a particular cancer. Nurses will need to embrace the paradigm shift to precision medicine, expend the effort necessary to learn the essential terminology, concepts and principles, and work collaboratively with physician colleagues to best position our patients to maximize the potential that precision medicine can offer. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. High precision anatomy for MEG.

    Science.gov (United States)

    Troebinger, Luzia; López, José David; Lutti, Antoine; Bradbury, David; Bestmann, Sven; Barnes, Gareth

    2014-02-01

    Precise MEG estimates of neuronal current flow are undermined by uncertain knowledge of the head location with respect to the MEG sensors. This is either due to head movements within the scanning session or systematic errors in co-registration to anatomy. Here we show how such errors can be minimized using subject-specific head-casts produced using 3D printing technology. The casts fit the scalp of the subject internally and the inside of the MEG dewar externally, reducing within session and between session head movements. Systematic errors in matching to MRI coordinate system are also reduced through the use of MRI-visible fiducial markers placed on the same cast. Bootstrap estimates of absolute co-registration error were of the order of 1mm. Estimates of relative co-registration error were <1.5mm between sessions. We corroborated these scalp based estimates by looking at the MEG data recorded over a 6month period. We found that the between session sensor variability of the subject's evoked response was of the order of the within session noise, showing no appreciable noise due to between-session movement. Simulations suggest that the between-session sensor level amplitude SNR improved by a factor of 5 over conventional strategies. We show that at this level of coregistration accuracy there is strong evidence for anatomical models based on the individual rather than canonical anatomy; but that this advantage disappears for errors of greater than 5mm. This work paves the way for source reconstruction methods which can exploit very high SNR signals and accurate anatomical models; and also significantly increases the sensitivity of longitudinal studies with MEG. © 2013. Published by Elsevier Inc. All rights reserved.

  16. High precision anatomy for MEG☆

    Science.gov (United States)

    Troebinger, Luzia; López, José David; Lutti, Antoine; Bradbury, David; Bestmann, Sven; Barnes, Gareth

    2014-01-01

    Precise MEG estimates of neuronal current flow are undermined by uncertain knowledge of the head location with respect to the MEG sensors. This is either due to head movements within the scanning session or systematic errors in co-registration to anatomy. Here we show how such errors can be minimized using subject-specific head-casts produced using 3D printing technology. The casts fit the scalp of the subject internally and the inside of the MEG dewar externally, reducing within session and between session head movements. Systematic errors in matching to MRI coordinate system are also reduced through the use of MRI-visible fiducial markers placed on the same cast. Bootstrap estimates of absolute co-registration error were of the order of 1 mm. Estimates of relative co-registration error were < 1.5 mm between sessions. We corroborated these scalp based estimates by looking at the MEG data recorded over a 6 month period. We found that the between session sensor variability of the subject's evoked response was of the order of the within session noise, showing no appreciable noise due to between-session movement. Simulations suggest that the between-session sensor level amplitude SNR improved by a factor of 5 over conventional strategies. We show that at this level of coregistration accuracy there is strong evidence for anatomical models based on the individual rather than canonical anatomy; but that this advantage disappears for errors of greater than 5 mm. This work paves the way for source reconstruction methods which can exploit very high SNR signals and accurate anatomical models; and also significantly increases the sensitivity of longitudinal studies with MEG. PMID:23911673

  17. Precision medicine: In need of guidance and surveillance.

    Science.gov (United States)

    Lin, Jian-Zhen; Long, Jun-Yu; Wang, An-Qiang; Zheng, Ying; Zhao, Hai-Tao

    2017-07-28

    Precision medicine, currently a hotspot in mainstream medicine, has been strongly promoted in recent years. With rapid technological development, such as next-generation sequencing, and fierce competition in molecular targeted drug exploitation, precision medicine represents an advance in science and technology; it also fulfills needs in public health care. The clinical translation and application of precision medicine - especially in the prevention and treatment of tumors - is far from satisfactory; however, the aims of precision medicine deserve approval. Thus, this medical approach is currently in its infancy; it has promising prospects, but it needs to overcome numbers of problems and deficiencies. It is expected that in addition to conventional symptoms and signs, precision medicine will define disease in terms of the underlying molecular characteristics and other environmental susceptibility factors. Those expectations should be realized by constructing a novel data network, integrating clinical data from individual patients and personal genomic background with existing research on the molecular makeup of diseases. In addition, multi-omics analysis and multi-discipline collaboration will become crucial elements in precision medicine. Precision medicine deserves strong support, and its development demands directed momentum. We propose three kinds of impetus (research, application and collaboration impetus) for such directed momentum toward promoting precision medicine and accelerating its clinical translation and application.

  18. Properties of the proton therapy. A high precision radiotherapy

    International Nuclear Information System (INIS)

    Anon.

    2005-01-01

    The proton therapy is a radiotherapy using protons beams. The protons present interesting characteristics but they need heavy technologies to be used, such particles accelerators, radiation protection wall and sophisticated technologies to reach the high precision allowed by their ballistic qualities (planning of treatment, beam conformation and patient positioning). (N.C.)

  19. WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Racine, E [Departement de Radio-Oncologie et Centre de Recherche du CHU de Quebec, Quebec, QC (Canada); Hautvast, G [Biomedical Systems, Philips Group Innovation, Eindhoven, North Brabant (Netherlands); Binnekamp, D [Integrated Clinical Solutions and Marketing, Philips Healthcare, Best, DA (Netherlands); Beaulieu, L [Centre Hospitalier University de Quebec, Quebec, QC (Canada)

    2014-06-15

    Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry

  20. WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

    International Nuclear Information System (INIS)

    Racine, E; Hautvast, G; Binnekamp, D; Beaulieu, L

    2014-01-01

    Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry

  1. Rapid Robot Design Validation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Energid Technologies will create a comprehensive software infrastructure for rapid validation of robot designs. The software will support push-button validation...

  2. Advanced bioanalytics for precision medicine.

    Science.gov (United States)

    Roda, Aldo; Michelini, Elisa; Caliceti, Cristiana; Guardigli, Massimo; Mirasoli, Mara; Simoni, Patrizia

    2018-01-01

    Precision medicine is a new paradigm that combines diagnostic, imaging, and analytical tools to produce accurate diagnoses and therapeutic interventions tailored to the individual patient. This approach stands in contrast to the traditional "one size fits all" concept, according to which researchers develop disease treatments and preventions for an "average" patient without considering individual differences. The "one size fits all" concept has led to many ineffective or inappropriate treatments, especially for pathologies such as Alzheimer's disease and cancer. Now, precision medicine is receiving massive funding in many countries, thanks to its social and economic potential in terms of improved disease prevention, diagnosis, and therapy. Bioanalytical chemistry is critical to precision medicine. This is because identifying an appropriate tailored therapy requires researchers to collect and analyze information on each patient's specific molecular biomarkers (e.g., proteins, nucleic acids, and metabolites). In other words, precision diagnostics is not possible without precise bioanalytical chemistry. This Trend article highlights some of the most recent advances, including massive analysis of multilayer omics, and new imaging technique applications suitable for implementing precision medicine. Graphical abstract Precision medicine combines bioanalytical chemistry, molecular diagnostics, and imaging tools for performing accurate diagnoses and selecting optimal therapies for each patient.

  3. Precision Oncology: Between Vaguely Right and Precisely Wrong.

    Science.gov (United States)

    Brock, Amy; Huang, Sui

    2017-12-01

    Precision Oncology seeks to identify and target the mutation that drives a tumor. Despite its straightforward rationale, concerns about its effectiveness are mounting. What is the biological explanation for the "imprecision?" First, Precision Oncology relies on indiscriminate sequencing of genomes in biopsies that barely represent the heterogeneous mix of tumor cells. Second, findings that defy the orthodoxy of oncogenic "driver mutations" are now accumulating: the ubiquitous presence of oncogenic mutations in silent premalignancies or the dynamic switching without mutations between various cell phenotypes that promote progression. Most troublesome is the observation that cancer cells that survive treatment still will have suffered cytotoxic stress and thereby enter a stem cell-like state, the seeds for recurrence. The benefit of "precision targeting" of mutations is inherently limited by this counterproductive effect. These findings confirm that there is no precise linear causal relationship between tumor genotype and phenotype, a reminder of logician Carveth Read's caution that being vaguely right may be preferable to being precisely wrong. An open-minded embrace of the latest inconvenient findings indicating nongenetic and "imprecise" phenotype dynamics of tumors as summarized in this review will be paramount if Precision Oncology is ultimately to lead to clinical benefits. Cancer Res; 77(23); 6473-9. ©2017 AACR . ©2017 American Association for Cancer Research.

  4. Numerical precision control and GRACE

    International Nuclear Information System (INIS)

    Fujimoto, J.; Hamaguchi, N.; Ishikawa, T.; Kaneko, T.; Morita, H.; Perret-Gallix, D.; Tokura, A.; Shimizu, Y.

    2006-01-01

    The control of the numerical precision of large-scale computations like those generated by the GRACE system for automatic Feynman diagram calculations has become an intrinsic part of those packages. Recently, Hitachi Ltd. has developed in FORTRAN a new library HMLIB for quadruple and octuple precision arithmetic where the number of lost-bits is made available. This library has been tested with success on the 1-loop radiative correction to e + e - ->e + e - τ + τ - . It is shown that the approach followed by HMLIB provides an efficient way to track down the source of numerical significance losses and to deliver high-precision results yet minimizing computing time

  5. Opportunities for Maturing Precision Metrology with Ultracold Gas Studies Aboard the ISS

    Science.gov (United States)

    Williams, Jason; D'Incao, Jose

    2017-04-01

    Precision atom interferometers (AI) in space are expected to become an enabling technology for future fundamental physics research, with proposals including unprecedented tests of the validity of the weak equivalence principle, measurements of the fine structure and gravitational constants, and detection of gravity waves and dark matter/dark energy. We will discuss our preparation at JPL to use NASA's Cold Atom Lab facility (CAL) to mature the technology of precision, space-based, AIs. The focus of our flight project is three-fold: a) study the controlled dynamics of heteronuclear Feshbach molecules, at temperatures of nano-Kelvins or below, as a means to overcome uncontrolled density-profile-dependent shifts in differential AIs, b) demonstrate unprecedented atom-photon coherence times with spatially constrained AIs, c) use the imaging capabilities of CAL to detect and analyze spatial fringe patterns written onto the clouds after AI and thereby measure the rotational noise of the ISS. The impact from this work, and potential for follow-on studies, will also be reviewed in the context of future space-based fundamental physics missions. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

  6. Estimating maneuvers for precise relative orbit determination using GPS

    Science.gov (United States)

    Allende-Alba, Gerardo; Montenbruck, Oliver; Ardaens, Jean-Sébastien; Wermuth, Martin; Hugentobler, Urs

    2017-01-01

    Precise relative orbit determination is an essential element for the generation of science products from distributed instrumentation of formation flying satellites in low Earth orbit. According to the mission profile, the required formation is typically maintained and/or controlled by executing maneuvers. In order to generate consistent and precise orbit products, a strategy for maneuver handling is mandatory in order to avoid discontinuities or precision degradation before, after and during maneuver execution. Precise orbit determination offers the possibility of maneuver estimation in an adjustment of single-satellite trajectories using GPS measurements. However, a consistent formulation of a precise relative orbit determination scheme requires the implementation of a maneuver estimation strategy which can be used, in addition, to improve the precision of maneuver estimates by drawing upon the use of differential GPS measurements. The present study introduces a method for precise relative orbit determination based on a reduced-dynamic batch processing of differential GPS pseudorange and carrier phase measurements, which includes maneuver estimation as part of the relative orbit adjustment. The proposed method has been validated using flight data from space missions with different rates of maneuvering activity, including the GRACE, TanDEM-X and PRISMA missions. The results show the feasibility of obtaining precise relative orbits without degradation in the vicinity of maneuvers as well as improved maneuver estimates that can be used for better maneuver planning in flight dynamics operations.

  7. The Telemetric and Holter ECG Warehouse Initiative (THEW): a Data Repository for the Design, Implementation and Validation of ECG-related Technologies

    Science.gov (United States)

    Couderc, Jean-Philippe

    2011-01-01

    We present an initiative supported by the National Heart Lung, and Blood Institute and the Food and Drug Administration for the development of a repository containing continuous electrocardiographic information to be shared with the worldwide scientific community. We believe that sharing data reinforces open scientific inquiry. It encourages diversity of analysis and opinion while promoting new research and facilitating the education of new researchers. In this paper, we present the resources available in this initiative for the scientific community. We describe the set of ECG signals currently hosted and we briefly discuss the associated clinical information (medical history. Disease and study-specific endpoints) and software tools we propose. Currently, the repository contains more than 250GB of data from eight clinical studies including healthy individuals and cardiac patients. This data is available for the development, implementation and validation of technologies related to body-surface ECGs. To conclude, the Telemetric and Holter ECG Warehouse (THEW) is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. PMID:21097349

  8. Lung Cancer Precision Medicine Trials

    Science.gov (United States)

    Patients with lung cancer are benefiting from the boom in targeted and immune-based therapies. With a series of precision medicine trials, NCI is keeping pace with the rapidly changing treatment landscape for lung cancer.

  9. How GNSS Enables Precision Farming

    Science.gov (United States)

    2014-12-01

    Precision farming: Feeding a Growing Population Enables Those Who Feed the World. Immediate and Ongoing Needs - population growth (more to feed) - urbanization (decrease in arable land) Double food production by 2050 to meet world demand. To meet thi...

  10. Lasers the power and precision of light

    CERN Document Server

    Diels, Jean-Claude

    2011-01-01

    ""Lasers"" are active ingredients of our modern life, but they are inconspicuous as they often go unnoticed. This intuitive introductory guide will tell you all you want to know about laser technologies in very diverse fields from nuclear and particle physics to medicine, astronomy and ultra-precise metrology. The book is coherently focused on fundamentals, and is aimed to stimulate intuition about present and future applications, while unveiling the halo of myths around lasers. Written by reputable laser experts who think that science should be entertaining, this useful reference relies on si

  11. Precision Medicine and the Changing Landscape of Research Ethics.

    Science.gov (United States)

    Hammer, Marilyn J

    2016-03-01

    President Barack Obama announced the launch of the National Institutes of Health Precision Medicine Initiative® (PMI) in January 2015. Precision medicine includes the concept of individualized or personalized medicine at a more exact level through advances in science and technology, such as genetics and genomics sequencing. Although many disease processes will be investigated through the precision medicine lens for greater understanding and improved treatment responses, oncology research and translation to practice is leading the initiative's debut, referred to as the near-term focus.

  12. Product Surfaces in Precision Engineering, Micorengineering and Nanotechnology

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Kunzmann, H.; Peggs, G. N.

    2005-01-01

    This paper is and excerpt from a recently published CIRP Key-Note paper on surfaces in Precision Engineering, Micorengineering and Nanotechnology [1]. It is focussed on the relevance of surface metrology at the micrometric and nanometric length scales. The applied measurement technologies...... are strongly dependent from the functional requirements on those surfaces. Examples of surfaces obtained with precision engineering, microengineering and nanotechnology are mentioned, encompassing surfaces in computers, MEMS, biomedical systems, ligth and X-ray optics, as well as in chemical systems. Surface...... in surface metrology at micro and nanoscale are strongly required for future progress of Precision Engineering, Microengineering, and Nanotechnology; and their fundamental importance can not be overestimated....

  13. Predictive timing disturbance is a precise marker of schizophrenia

    Directory of Open Access Journals (Sweden)

    Valentina Ciullo

    2018-06-01

    Our findings shed new light on the debate over the specificity of timing distortions in SZ, providing evidence that predictive timing is a precise marker of SZ, more sensitive than duration estimation, serving as a valid heuristic for studying the pathophysiology of the disorder.

  14. Precision lens assembly with alignment turning system

    Science.gov (United States)

    Ho, Cheng-Fang; Huang, Chien-Yao; Lin, Yi-Hao; Kuo, Hui-Jean; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Chen, Fong-Zhi

    2017-10-01

    The poker chip assembly with high precision lens barrels is widely applied to ultra-high performance optical system. ITRC applies the poker chip assembly technology to the high numerical aperture objective lenses and lithography projection lenses because of its high efficiency assembly process. In order to achieve high precision lens cell for poker chip assembly, an alignment turning system (ATS) is developed. The ATS includes measurement, alignment and turning modules. The measurement module is equipped with a non-contact displacement sensor (NCDS) and an autocollimator (ACM). The NCDS and ACM are used to measure centration errors of the top and the bottom surface of a lens respectively; then the amount of adjustment of displacement and tilt with respect to the rotational axis of the turning machine for the alignment module can be determined. After measurement, alignment and turning processes on the ATS, the centration error of a lens cell with 200 mm in diameter can be controlled within 10 arcsec. Furthermore, a poker chip assembly lens cell with three sub-cells is demonstrated, each sub-cells are measured and accomplished with alignment and turning processes. The lens assembly test for five times by each three technicians; the average transmission centration error of assembly lens is 12.45 arcsec. The results show that ATS can achieve high assembly efficiency for precision optical systems.

  15. Validation of birth outcomes from the Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS): population-based analysis from the Massachusetts Outcome Study of Assisted Reproductive Technology (MOSART).

    Science.gov (United States)

    Stern, Judy E; Gopal, Daksha; Liberman, Rebecca F; Anderka, Marlene; Kotelchuck, Milton; Luke, Barbara

    2016-09-01

    To assess the validity of outcome data reported to the Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS) compared with data from vital records and the birth defects registry in Massachusetts. Longitudinal cohort. Not applicable. A total of 342,035 live births and fetal deaths from Massachusetts mothers giving birth in the state from July 1, 2004, to December 31, 2008; 9,092 births and fetal deaths were from mothers who had conceived with the use of assisted reproductive technology (ART) and whose cycle data had been reported to the SART CORS. Not applicable. Percentage agreement between maternal race and ethnicity, delivery outcome (live birth or fetal death), plurality (singleton, twin, or triplet+), delivery date, and singleton birth weight reported in the SART CORS versus vital records; sensitivity and specificity for birth defects among singletons as reported in the SART CORS versus the Massachusetts Birth Defects Monitoring Program (BDMP). There was >95% agreement between the SART CORS and vital records for fields of maternal race/ethnicity, live birth/fetal death, and plurality; birth outcome date was within 1 day with 94.9% agreement and birth weight was within 100 g with 89.6% agreement. In contrast, sensitivity for report of any birth defect was 38.6%, with a range of 18.4%-50.0%, for specific birth defect categories. Although most SART CORS outcome fields are accurately reported, birth defect variables showed poor sensitivity compared with the gold standard data from the BDMP. We suggest that reporting of birth defects be discontinued. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  16. Assessing the validity and reliability of self-report data on contraception use in the MObile Technology for Improved Family Planning (MOTIF) randomised controlled trial.

    Science.gov (United States)

    Smith, Chris; Edwards, Phil; Free, Caroline

    2018-03-15

    A variety of different approaches to measuring contraceptive use have been used or proposed, either to assess current use or adherence over time, using subjective or objective measures. This paper reports an overview of approaches to measuring adherence to the oral contraceptive, intra-uterine device, sub-dermal implant, and injectable and describes how we assessed contraception use in the MObile Technology for Improved Family Planning (MOTIF) trial in Cambodia. We summarise and discuss advantages and disadvantages of different subjective and objective approaches to measuring adherence to the oral contraceptive, intra-uterine device, sub-dermal implant, and injectable such as self-reports, clinic records, electronic monitoring devices, clinical examination and biomarkers. For the MOTIF trial, we did not consider it feasible to measure objective contraception use as many participants lived a long distance from the clinic and we were concerned whether it was appropriate to ask women to return to clinic for a physical examination simply to verify self-report information already provided. We aimed to assess the validity of the four-month data with 50 participants, calculating the sensitivity and specificity of self-reported data compared with objective measurement. For the 46 valid measurements obtained, the sensitivity and specificity was 100% for self-reported contraception use compared to objective measurement but this study had some limitations. To assess reliability of self-report data we compared calendar data collected on effective contraception use at months 1-4 post-abortion, collected separately at four and 12 months. Agreement ranged from 80 to 84% with a kappa statistic ranging from 0·59 to 0·67 indicating fair to good agreement. There is no perfect method of assessing contraception use and researchers designing future studies should give consideration of what to measure, for example current use or detailed patterns of use over time, and remain mindful

  17. GTCBio's Precision Medicine Conference (July 7-8, 2016 - Boston, Massachusetts, USA).

    Science.gov (United States)

    Cole, P

    2016-09-01

    GTCBio's Precision Medicine Conference met this year to outline the many steps forward that precision medicine and individualized genomics has made and the challenges it still faces in technological, modeling, and standards development, interoperability and compatibility advancements, and methods of economic and societal adoption. The conference was split into four sections, 'Overcoming Challenges in the Commercialization of Precision Medicine', 'Implementation of Precision Medicine: Strategies & Technologies', 'Integrating & Interpreting Personal Genomics, Big Data, & Bioinformatics' and 'Incentivizing Precision Medicine: Regulation & Reimbursement', with this report focusing on the final two subjects. Copyright 2016 Prous Science, S.A.U. or its licensors. All rights reserved.

  18. Assessment of precision and reproducibility of a new myograph

    Directory of Open Access Journals (Sweden)

    Piepenbrock Siegfried

    2007-12-01

    Full Text Available Abstract Background The physiological characteristics of muscle activity and the assessment of muscle strength represent important diagnostic information. There are many devices that measure muscle force in humans, but some require voluntary contractions, which are difficult to assess in weak or unconscious patients who are unable to complete a full range of voluntary force assessment tasks. Other devices, which obtain standard muscle contractions by electric stimulations, do not have the technology required to induce and measure reproducible valid contractions at the optimum muscle length. Methods In our study we used a newly developed diagnostic device which measures accurately the reproducibility and time-changed-variability of the muscle force in an individual muscle. A total of 500 in-vivo measurements of supra-maximal isometric single twitch contractions were carried out on the musculus adductor pollicis of 5 test subjects over 10 sessions, with ten repetitions per session. The same protocol was performed on 405 test subjects with two repetitions each to determine a reference-interval on healthy subjects. Results Using our test setting, we found a high reproducibility of the muscle contractions of each test subject. The precision of the measurements performed with our device was 98.74%. Only two consecutive measurements are needed in order to assess a real, representative individual value of muscle force. The mean value of the force of contraction was 9.51 N and the 95% reference interval was 4.77–14.25 N. Conclusion The new myograph is a highly reliable measuring device with which the adductor pollicis can be investigated at the optimum length. It has the potential to become a reliable and valid tool for diagnostic in the clinical setting and for monitoring neuromuscular diseases.

  19. Nanomaterials for Cancer Precision Medicine.

    Science.gov (United States)

    Wang, Yilong; Sun, Shuyang; Zhang, Zhiyuan; Shi, Donglu

    2018-04-01

    Medical science has recently advanced to the point where diagnosis and therapeutics can be carried out with high precision, even at the molecular level. A new field of "precision medicine" has consequently emerged with specific clinical implications and challenges that can be well-addressed by newly developed nanomaterials. Here, a nanoscience approach to precision medicine is provided, with a focus on cancer therapy, based on a new concept of "molecularly-defined cancers." "Next-generation sequencing" is introduced to identify the oncogene that is responsible for a class of cancers. This new approach is fundamentally different from all conventional cancer therapies that rely on diagnosis of the anatomic origins where the tumors are found. To treat cancers at molecular level, a recently developed "microRNA replacement therapy" is applied, utilizing nanocarriers, in order to regulate the driver oncogene, which is the core of cancer precision therapeutics. Furthermore, the outcome of the nanomediated oncogenic regulation has to be accurately assessed by the genetically characterized, patient-derived xenograft models. Cancer therapy in this fashion is a quintessential example of precision medicine, presenting many challenges to the materials communities with new issues in structural design, surface functionalization, gene/drug storage and delivery, cell targeting, and medical imaging. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Precision Medicine and Men's Health.

    Science.gov (United States)

    Mata, Douglas A; Katchi, Farhan M; Ramasamy, Ranjith

    2017-07-01

    Precision medicine can greatly benefit men's health by helping to prevent, diagnose, and treat prostate cancer, benign prostatic hyperplasia, infertility, hypogonadism, and erectile dysfunction. For example, precision medicine can facilitate the selection of men at high risk for prostate cancer for targeted prostate-specific antigen screening and chemoprevention administration, as well as assist in identifying men who are resistant to medical therapy for prostatic hyperplasia, who may instead require surgery. Precision medicine-trained clinicians can also let couples know whether their specific cause of infertility should be bypassed by sperm extraction and in vitro fertilization to prevent abnormalities in their offspring. Though precision medicine's role in the management of hypogonadism has yet to be defined, it could be used to identify biomarkers associated with individual patients' responses to treatment so that appropriate therapy can be prescribed. Last, precision medicine can improve erectile dysfunction treatment by identifying genetic polymorphisms that regulate response to medical therapies and by aiding in the selection of patients for further cardiovascular disease screening.

  1. Precision Medicine in Gastrointestinal Pathology.

    Science.gov (United States)

    Wang, David H; Park, Jason Y

    2016-05-01

    -Precision medicine is the promise of individualized therapy and management of patients based on their personal biology. There are now multiple global initiatives to perform whole-genome sequencing on millions of individuals. In the United States, an early program was the Million Veteran Program, and a more recent proposal in 2015 by the president of the United States is the Precision Medicine Initiative. To implement precision medicine in routine oncology care, genetic variants present in tumors need to be matched with effective clinical therapeutics. When we focus on the current state of precision medicine for gastrointestinal malignancies, it becomes apparent that there is a mixed history of success and failure. -To present the current state of precision medicine using gastrointestinal oncology as a model. We will present currently available targeted therapeutics, promising new findings in clinical genomic oncology, remaining quality issues in genomic testing, and emerging oncology clinical trial designs. -Review of the literature including clinical genomic studies on gastrointestinal malignancies, clinical oncology trials on therapeutics targeted to molecular alterations, and emerging clinical oncology study designs. -Translating our ability to sequence thousands of genes into meaningful improvements in patient survival will be the challenge for the next decade.

  2. Usefulness of Models in Precision Nutrient Management

    DEFF Research Database (Denmark)

    Plauborg, Finn; Manevski, Kiril; Zhenjiang, Zhou

    Modern agriculture increasingly applies new methods and technologies to increase production and nutrient use efficiencies and at the same time reduce leaching of nutrients and greenhouse gas emissions. GPS based ECa-measurement equipment, ER or EM instrumentations, are used to spatially character......Modern agriculture increasingly applies new methods and technologies to increase production and nutrient use efficiencies and at the same time reduce leaching of nutrients and greenhouse gas emissions. GPS based ECa-measurement equipment, ER or EM instrumentations, are used to spatially...... and mineral composition. Mapping of crop status and the spatial-temporal variability within fields with red-infrared reflection are used to support decision on split fertilisation and more precise dosing. The interpretation and use of these various data in precise nutrient management is not straightforward...... of mineralisation. However, whether the crop would benefit from this depended to a large extent on soil hydraulic conductivity within the range of natural variation when testing the model. In addition the initialisation of the distribution of soil total carbon and nitrogen into conceptual model compartments...

  3. Gene mutation-based and specific therapies in precision medicine.

    Science.gov (United States)

    Wang, Xiangdong

    2016-04-01

    Precision medicine has been initiated and gains more and more attention from preclinical and clinical scientists. A number of key elements or critical parts in precision medicine have been described and emphasized to establish a systems understanding of precision medicine. The principle of precision medicine is to treat patients on the basis of genetic alterations after gene mutations are identified, although questions and challenges still remain before clinical application. Therapeutic strategies of precision medicine should be considered according to gene mutation, after biological and functional mechanisms of mutated gene expression or epigenetics, or the correspondent protein, are clearly validated. It is time to explore and develop a strategy to target and correct mutated genes by direct elimination, restoration, correction or repair of mutated sequences/genes. Nevertheless, there are still numerous challenges to integrating widespread genomic testing into individual cancer therapies and into decision making for one or another treatment. There are wide-ranging and complex issues to be solved before precision medicine becomes clinical reality. Thus, the precision medicine can be considered as an extension and part of clinical and translational medicine, a new alternative of clinical therapies and strategies, and have an important impact on disease cures and patient prognoses. © 2015 The Author. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  4. Precision measurement with atom interferometry

    International Nuclear Information System (INIS)

    Wang Jin

    2015-01-01

    Development of atom interferometry and its application in precision measurement are reviewed in this paper. The principle, features and the implementation of atom interferometers are introduced, the recent progress of precision measurement with atom interferometry, including determination of gravitational constant and fine structure constant, measurement of gravity, gravity gradient and rotation, test of weak equivalence principle, proposal of gravitational wave detection, and measurement of quadratic Zeeman shift are reviewed in detail. Determination of gravitational redshift, new definition of kilogram, and measurement of weak force with atom interferometry are also briefly introduced. (topical review)

  5. ELECTROWEAK PHYSICS AND PRECISION STUDIES

    International Nuclear Information System (INIS)

    MARCIANO, W.

    2005-01-01

    The utility of precision electroweak measurements for predicting the Standard Model Higgs mass via quantum loop effects is discussed. Current values of m W , sin 2 θ W (m Z ) # ovr MS# and m t imply a relatively light Higgs which is below the direct experimental bound but possibly consistent with Supersymmetry expectations. The existence of Supersymmetry is further suggested by a 2σ discrepancy between experiment and theory for the muon anomalous magnetic moment. Constraints from precision studies on other types of ''New Physics'' are also briefly described

  6. Universal precision sine bar attachment

    Science.gov (United States)

    Mann, Franklin D. (Inventor)

    1989-01-01

    This invention relates to an attachment for a sine bar which can be used to perform measurements during lathe operations or other types of machining operations. The attachment can be used for setting precision angles on vises, dividing heads, rotary tables and angle plates. It can also be used in the inspection of machined parts, when close tolerances are required, and in the layout of precision hardware. The novelty of the invention is believed to reside in a specific versatile sine bar attachment for measuring a variety of angles on a number of different types of equipment.

  7. Introduction to precise numerical methods

    CERN Document Server

    Aberth, Oliver

    2007-01-01

    Precise numerical analysis may be defined as the study of computer methods for solving mathematical problems either exactly or to prescribed accuracy. This book explains how precise numerical analysis is constructed. The book also provides exercises which illustrate points from the text and references for the methods presented. All disc-based content for this title is now available on the Web. · Clearer, simpler descriptions and explanations ofthe various numerical methods· Two new types of numerical problems; accurately solving partial differential equations with the included software and computing line integrals in the complex plane.

  8. PRECISE COSMIC RAYS MEASUREMENTS WITH PAMELA

    Directory of Open Access Journals (Sweden)

    A. Bruno

    2013-12-01

    Full Text Available The PAMELA experiment was launched on board the Resurs-DK1 satellite on June 15th 2006. The apparatus was designed to conduct precision studies of charged cosmic radiation over a wide energy range, from tens of MeV up to several hundred GeV, with unprecedented statistics. In five years of continuous data taking in space, PAMELA accurately measured the energy spectra of cosmic ray antiprotons and positrons, as well as protons, electrons and light nuclei, sometimes providing data in unexplored energetic regions. These important results have shed new light in several astrophysical fields like: an indirect search for Dark Matter, a search for cosmological antimatter (anti-Helium, and the validation of acceleration, transport and secondary production models of cosmic rays in the Galaxy. Some of the most important items of Solar and Magnetospheric physics were also investigated. Here we present the most recent results obtained by the PAMELA experiment.

  9. Developing a new wireless sensor network platform and its application in precision agriculture.

    Science.gov (United States)

    Aquino-Santos, Raúl; González-Potes, Apolinar; Edwards-Block, Arthur; Virgen-Ortiz, Raúl Alejandro

    2011-01-01

    Wireless sensor networks are gaining greater attention from the research community and industrial professionals because these small pieces of "smart dust" offer great advantages due to their small size, low power consumption, easy integration and support for "green" applications. Green applications are considered a hot topic in intelligent environments, ubiquitous and pervasive computing. This work evaluates a new wireless sensor network platform and its application in precision agriculture, including its embedded operating system and its routing algorithm. To validate the technological platform and the embedded operating system, two different routing strategies were compared: hierarchical and flat. Both of these routing algorithms were tested in a small-scale network applied to a watermelon field. However, we strongly believe that this technological platform can be also applied to precision agriculture because it incorporates a modified version of LORA-CBF, a wireless location-based routing algorithm that uses cluster-based flooding. Cluster-based flooding addresses the scalability concerns of wireless sensor networks, while the modified LORA-CBF routing algorithm includes a metric to monitor residual battery energy. Furthermore, results show that the modified version of LORA-CBF functions well with both the flat and hierarchical algorithms, although it functions better with the flat algorithm in a small-scale agricultural network.

  10. Developing a New Wireless Sensor Network Platform and Its Application in Precision Agriculture

    Science.gov (United States)

    Aquino-Santos, Raúl; González-Potes, Apolinar; Edwards-Block, Arthur; Virgen-Ortiz, Raúl Alejandro

    2011-01-01

    Wireless sensor networks are gaining greater attention from the research community and industrial professionals because these small pieces of “smart dust” offer great advantages due to their small size, low power consumption, easy integration and support for “green” applications. Green applications are considered a hot topic in intelligent environments, ubiquitous and pervasive computing. This work evaluates a new wireless sensor network platform and its application in precision agriculture, including its embedded operating system and its routing algorithm. To validate the technological platform and the embedded operating system, two different routing strategies were compared: hierarchical and flat. Both of these routing algorithms were tested in a small-scale network applied to a watermelon field. However, we strongly believe that this technological platform can be also applied to precision agriculture because it incorporates a modified version of LORA-CBF, a wireless location-based routing algorithm that uses cluster-based flooding. Cluster-based flooding addresses the scalability concerns of wireless sensor networks, while the modified LORA-CBF routing algorithm includes a metric to monitor residual battery energy. Furthermore, results show that the modified version of LORA-CBF functions well with both the flat and hierarchical algorithms, although it functions better with the flat algorithm in a small-scale agricultural network. PMID:22346622

  11. STANFORD (SLAC): Precision electroweak result

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Precision testing of the electroweak sector of the Standard Model has intensified with the recent publication* of results from the SLD collaboration's 1993 run on the Stanford Linear Collider, SLC. Using a highly polarized electron beam colliding with an unpolarized positron beam, SLD physicists measured the left-right asymmetry at the Z boson resonance with dramatically improved accuracy over 1992

  12. Spin and precision electroweak physics

    Energy Technology Data Exchange (ETDEWEB)

    Marciano, W.J. [Brookhaven National Lab., Upton, NY (United States)

    1994-12-01

    A perspective on fundamental parameters and precision tests of the Standard Model is given. Weak neutral current reactions are discussed with emphasis on those processes involving (polarized) electrons. The role of electroweak radiative corrections in determining the top quark mass and probing for {open_quotes}new physics{close_quotes} is described.

  13. Spin and precision electroweak physics

    International Nuclear Information System (INIS)

    Marciano, W.J.

    1993-01-01

    A perspective on fundamental parameters and precision tests of the Standard Model is given. Weak neutral current reactions are discussed with emphasis on those processes involving (polarized) electrons. The role of electroweak radiative corrections in determining the top quark mass and probing for ''new physics'' is described

  14. Precision surveying system for PEP

    International Nuclear Information System (INIS)

    Gunn, J.; Lauritzen, T.; Sah, R.; Pellisier, P.F.

    1977-01-01

    A semi-automatic precision surveying system is being developed for PEP. Reference elevations for vertical alignment will be provided by a liquid level. The short range surveying will be accomplished using a Laser Surveying System featuring automatic data acquisition and analysis

  15. Precision medicine at the crossroads.

    Science.gov (United States)

    Olson, Maynard V

    2017-10-11

    There are bioethical, institutional, economic, legal, and cultural obstacles to creating the robust-precompetitive-data resource that will be required to advance the vision of "precision medicine," the ability to use molecular data to target therapies to patients for whom they offer the most benefit at the least risk. Creation of such an "information commons" was the central recommendation of the 2011 report Toward Precision Medicine issued by a committee of the National Research Council of the USA (Committee on a Framework for Development of a New Taxonomy of Disease; National Research Council. Toward precision medicine: building a knowledge network for biomedical research and a new taxonomy of disease. 2011). In this commentary, I review the rationale for creating an information commons and the obstacles to doing so; then, I endorse a path forward based on the dynamic consent of research subjects interacting with researchers through trusted mediators. I assert that the advantages of the proposed system overwhelm alternative ways of handling data on the phenotypes, genotypes, and environmental exposures of individual humans; hence, I argue that its creation should be the central policy objective of early efforts to make precision medicine a reality.

  16. Proton gyromagnetic precision measurement system

    International Nuclear Information System (INIS)

    Zhu Deming; Deming Zhu

    1991-01-01

    A computerized control and measurement system used in the proton gyromagnetic precision meausrement is descirbed. It adopts the CAMAC data acquisition equipment, using on-line control and analysis with the HP85 and PDP-11/60 computer systems. It also adopts the RSX11M computer operation system, and the control software is written in FORTRAN language

  17. Precise Point Positioning with Partial Ambiguity Fixing.

    Science.gov (United States)

    Li, Pan; Zhang, Xiaohong

    2015-06-10

    Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate.

  18. Explicating Validity

    Science.gov (United States)

    Kane, Michael T.

    2016-01-01

    How we choose to use a term depends on what we want to do with it. If "validity" is to be used to support a score interpretation, validation would require an analysis of the plausibility of that interpretation. If validity is to be used to support score uses, validation would require an analysis of the appropriateness of the proposed…

  19. The Development and Validation of an Instrument for Assessing College Students' Perceptions of Faculty Knowledge in Technology-Supported Class Environments

    Science.gov (United States)

    Shih, Ching-Lin; Chuang, Hsueh-Hua

    2013-01-01

    Research in the area of educational technology has argued that the technological pedagogical content knowledge of faculty is crucial to addressing the challenge of teaching in higher education in the digital age, which is characterized by the common use of instructional technology in college classrooms and the ubiquitous presence of computing on…

  20. Study of the precision guided communication of digital television

    Science.gov (United States)

    Liu, Lun

    2012-04-01

    Along with the progress and development of the digital technology, there produced the transmission of the new media by medium of such as the network, mobile phones and the digital television, while among them digital TV has the superiority of other media. The appearance and development of digital TV will induce a profound change in the broadcasting and television industry chain. This paper started with discussing the transformation of digital television in profit model, mode of operation and mode of transmission to construct the precision-guided communication theory; And then analyzes the properties and marketing nature of the precision-guided communication to make the construction of the precision-guided communication marketing mode; And put forward the implementing of the precision-guided communication marketing strategies and concrete steps; At the end of the article the author summarized four conclusions.

  1. The PPP Precision Analysis Based on BDS Regional Navigation System

    Directory of Open Access Journals (Sweden)

    ZHU Yongxing

    2015-04-01

    Full Text Available BeiDou navigation satellite system(BDS has opened service in most of the Asia-Pacific region, it offers the possibility to break the technological monopoly of GPS in the field of high-precision applications, so its performance of precise point positioning (PPP has been a great concern. Firstly, the constellation of BeiDou regional navigation system and BDS/GPS tracking network is introduced. Secondly, the precise ephemeris and clock offset accuracy of BeiDou satellite based on domestic tracking network is analyzed. Finally, the static and kinematic PPP accuracy is studied, and compared with the GPS. The actual measured numerical example shows that the static and kinematic PPP based on BDS can achieve centimeter-level and decimeter-level respectively, reaching the current level of GPS precise point positioning.

  2. Mobile technology and telemedicine for shoulder range of motion: validation of a motion-based machine-learning software development kit.

    Science.gov (United States)

    Ramkumar, Prem N; Haeberle, Heather S; Navarro, Sergio M; Sultan, Assem A; Mont, Michael A; Ricchetti, Eric T; Schickendantz, Mark S; Iannotti, Joseph P

    2018-03-07

    Mobile technology offers the prospect of delivering high-value care with increased patient access and reduced costs. Advances in mobile health (mHealth) and telemedicine have been inhibited by the lack of interconnectivity between devices and software and inability to process consumer sensor data. The objective of this study was to preliminarily validate a motion-based machine learning software development kit (SDK) for the shoulder compared with a goniometer for 4 arcs of motion: (1) abduction, (2) forward flexion, (3) internal rotation, and (4) external rotation. A mobile application for the SDK was developed and "taught" 4 arcs of shoulder motion. Ten subjects without shoulder pain or prior shoulder surgery performed the arcs of motion for 5 repetitions. Each motion was measured by the SDK and compared with a physician-measured manual goniometer measurement. Angular differences between SDK and goniometer measurements were compared with univariate and power analyses. The comparison between the SDK and goniometer measurement detected a mean difference of less than 5° for all arcs of motion (P > .05), with a 94% chance of detecting a large effect size from a priori power analysis. Mean differences for the arcs of motion were: abduction, -3.7° ± 3.2°; forward flexion, -4.9° ± 2.5°; internal rotation, -2.4° ± 3.7°; and external rotation -2.6° ± 3.4°. The SDK has the potential to remotely substitute for a shoulder range of motion examination within 5° of goniometer measurements. An open-source motion-based SDK that can learn complex movements, including clinical shoulder range of motion, from consumer sensors offers promise for the future of mHealth, particularly in telemonitoring before and after orthopedic surgery. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. FY 1999 research and development of technologies for creating original high-function materials. Development of technologies for functionalized materials for power generating facilities (Report on the R and D results of controlling precise structures of polycondesed systems); 1999 nendo dokusoteki kokino zairyo sosei gijutsu no kenkyu kaihatsu seika hokokusho. Hatsuden shisetsuyo koseinoka zairyo gijutsu kaihatsu (shukugokei seimitsu kozo seigyo no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The research and development project is implemented for the polymerization catalysts and precise polymerization processes which can freely control the primary structures, e.g., molecular weight, regularity, branching and terminal group structures, of the polymers produced by polycondensation and ring-opening polymerization, in order to drastically improve their functions, and the FY 1999 results are reported. The basic studies on the precise polycondensation successfully lead to chemoselective synthesis of polymers by the direct polymerization, and synthesis of polyamides of narrow molecular weight distribution and high-molecular-weight aliphatic polyesters. The other items studied include precisely, regularly sequential polymerization by amine activation, innovative synthesis of polycarbonate, precise control of branching structures, regioselective oxidative coupling polymerization, and matrix polycondensation. The basic studies on the controlled ring-opening polymerization cover cationic ring-opening polymerization behavior of 6-membered thiocarbonate derivative having an ester group, to generalize the polymerization controlled by neighboring group participation. The other items studied include precise control of branching structures, molecular weights, network polymer structures, and polymer unit sequences. (NEDO)

  4. Molecular Classification and Pharmacogenetics of Primary Plasma Cell Leukemia: An Initial Approach toward Precision Medicine.

    Science.gov (United States)

    Simeon, Vittorio; Todoerti, Katia; La Rocca, Francesco; Caivano, Antonella; Trino, Stefania; Lionetti, Marta; Agnelli, Luca; De Luca, Luciana; Laurenzana, Ilaria; Neri, Antonino; Musto, Pellegrino

    2015-07-30

    Primary plasma cell leukemia (pPCL) is a rare and aggressive variant of multiple myeloma (MM) which may represent a valid model for high-risk MM. This disease is associated with a very poor prognosis, and unfortunately, it has not significantly improved during the last three decades. New high-throughput technologies have allowed a better understanding of the molecular basis of this disease and moved toward risk stratification, providing insights for targeted therapy studies. This knowledge, added to the pharmacogenetic profile of new and old agents in the analysis of efficacy and safety, could contribute to help clinical decisions move toward a precision medicine and a better clinical outcome for these patients. In this review, we describe the available literature concerning the genomic characterization and pharmacogenetics of plasma cell leukemia (PCL).

  5. Technology forum Berlin '82. Technologieforum Berlin '82

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    36 articles are represented concerning mechanical engineering, materials, chemicals, communications and telecommunications technology, metal working, precision engineering and optics, microelectronics, plastics, information supplying, patent realization and technology transfer.

  6. Computer-determined assay time based on preset precision

    International Nuclear Information System (INIS)

    Foster, L.A.; Hagan, R.; Martin, E.R.; Wachter, J.R.; Bonner, C.A.; Malcom, J.E.

    1994-01-01

    Most current assay systems for special nuclear materials (SNM) operate on the principle of a fixed assay time which provides acceptable measurement precision without sacrificing the required throughput of the instrument. Waste items to be assayed for SNM content can contain a wide range of nuclear material. Counting all items for the same preset assay time results in a wide range of measurement precision and wastes time at the upper end of the calibration range. A short time sample taken at the beginning of the assay could optimize the analysis time on the basis of the required measurement precision. To illustrate the technique of automatically determining the assay time, measurements were made with a segmented gamma scanner at the Plutonium Facility of Los Alamos National Laboratory with the assay time for each segment determined by counting statistics in that segment. Segments with very little SNM were quickly determined to be below the lower limit of the measurement range and the measurement was stopped. Segments with significant SNM were optimally assays to the preset precision. With this method the total assay time for each item is determined by the desired preset precision. This report describes the precision-based algorithm and presents the results of measurements made to test its validity

  7. Precision and accuracy in radiotherapy

    International Nuclear Information System (INIS)

    Brenner, J.D.

    1989-01-01

    The required precision due to random errors in the delivery of fractionated dose regime is considered. It is argued that suggestions that 1-3% precision is needed may be unnecessarily conservative. It is further suggested that random and systematic errors should not be combined with equal weight to yield an overall target uncertainty in dose delivery, systematic errors being of greater significance. The authors conclude that imprecise dose delivery and inaccurate dose delivery affect patient-cure results differently. Whereas, for example, a 10% inaccuracy in dose delivery would be quite catastrophic in the case considered here, a corresponding imprecision would have a much smaller effect on overall success rates. (author). 14 refs.; 2 figs

  8. Precision electroweak physics at LEP

    Energy Technology Data Exchange (ETDEWEB)

    Mannelli, M.

    1994-12-01

    Copious event statistics, a precise understanding of the LEP energy scale, and a favorable experimental situation at the Z{sup 0} resonance have allowed the LEP experiments to provide both dramatic confirmation of the Standard Model of strong and electroweak interactions and to place substantially improved constraints on the parameters of the model. The author concentrates on those measurements relevant to the electroweak sector. It will be seen that the precision of these measurements probes sensitively the structure of the Standard Model at the one-loop level, where the calculation of the observables measured at LEP is affected by the value chosen for the top quark mass. One finds that the LEP measurements are consistent with the Standard Model, but only if the mass of the top quark is measured to be within a restricted range of about 20 GeV.

  9. Environment-assisted precision measurement

    DEFF Research Database (Denmark)

    Goldstein, G.; Cappellaro, P.; Maze, J. R.

    2011-01-01

    We describe a method to enhance the sensitivity of precision measurements that takes advantage of the environment of a quantum sensor to amplify the response of the sensor to weak external perturbations. An individual qubit is used to sense the dynamics of surrounding ancillary qubits, which...... are in turn affected by the external field to be measured. The resulting sensitivity enhancement is determined by the number of ancillas that are coupled strongly to the sensor qubit; it does not depend on the exact values of the coupling strengths and is resilient to many forms of decoherence. The method...... achieves nearly Heisenberg-limited precision measurement, using a novel class of entangled states. We discuss specific applications to improve clock sensitivity using trapped ions and magnetic sensing based on electronic spins in diamond...

  10. Precise object tracking under deformation

    International Nuclear Information System (INIS)

    Saad, M.H

    2010-01-01

    The precise object tracking is an essential issue in several serious applications such as; robot vision, automated surveillance (civil and military), inspection, biomedical image analysis, video coding, motion segmentation, human-machine interface, visualization, medical imaging, traffic systems, satellite imaging etc. This frame-work focuses on the precise object tracking under deformation such as scaling , rotation, noise, blurring and change of illumination. This research is a trail to solve these serious problems in visual object tracking by which the quality of the overall system will be improved. Developing a three dimensional (3D) geometrical model to determine the current pose of an object and predict its future location based on FIR model learned by the OLS. This framework presents a robust ranging technique to track a visual target instead of the traditional expensive ranging sensors. The presented research work is applied to real video stream and achieved high precession results.

  11. Rapid whole genome sequencing and precision neonatology.

    Science.gov (United States)

    Petrikin, Joshua E; Willig, Laurel K; Smith, Laurie D; Kingsmore, Stephen F

    2015-12-01

    Traditionally, genetic testing has been too slow or perceived to be impractical to initial management of the critically ill neonate. Technological advances have led to the ability to sequence and interpret the entire genome of a neonate in as little as 26 h. As the cost and speed of testing decreases, the utility of whole genome sequencing (WGS) of neonates for acute and latent genetic illness increases. Analyzing the entire genome allows for concomitant evaluation of the currently identified 5588 single gene diseases. When applied to a select population of ill infants in a level IV neonatal intensive care unit, WGS yielded a diagnosis of a causative genetic disease in 57% of patients. These diagnoses may lead to clinical management changes ranging from transition to palliative care for uniformly lethal conditions for alteration or initiation of medical or surgical therapy to improve outcomes in others. Thus, institution of 2-day WGS at time of acute presentation opens the possibility of early implementation of precision medicine. This implementation may create opportunities for early interventional, frequently novel or off-label therapies that may alter disease trajectory in infants with what would otherwise be fatal disease. Widespread deployment of rapid WGS and precision medicine will raise ethical issues pertaining to interpretation of variants of unknown significance, discovery of incidental findings related to adult onset conditions and carrier status, and implementation of medical therapies for which little is known in terms of risks and benefits. Despite these challenges, precision neonatology has significant potential both to decrease infant mortality related to genetic diseases with onset in newborns and to facilitate parental decision making regarding transition to palliative care. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Fit to Electroweak Precision Data

    International Nuclear Information System (INIS)

    Erler, Jens

    2006-01-01

    A brief review of electroweak precision data from LEP, SLC, the Tevatron, and low energies is presented. The global fit to all data including the most recent results on the masses of the top quark and the W boson reinforces the preference for a relatively light Higgs boson. I will also give an outlook on future developments at the Tevatron Run II, CEBAF, the LHC, and the ILC

  13. Precise Object Tracking under Deformation

    International Nuclear Information System (INIS)

    Saad, M.H.

    2010-01-01

    The precise object tracking is an essential issue in several serious applications such as; robot vision, automated surveillance (civil and military), inspection, biomedical image analysis, video coding, motion segmentation, human-machine interface, visualization, medical imaging, traffic systems, satellite imaging etc. This framework focuses on the precise object tracking under deformation such as scaling, rotation, noise, blurring and change of illumination. This research is a trail to solve these serious problems in visual object tracking by which the quality of the overall system will be improved. Developing a three dimensional (3D) geometrical model to determine the current pose of an object and predict its future location based on FIR model learned by the OLS. This framework presents a robust ranging technique to track a visual target instead of the traditional expensive ranging sensors. The presented research work is applied to real video stream and achieved high precession results. xiiiThe precise object tracking is an essential issue in several serious applications such as; robot vision, automated surveillance (civil and military), inspection, biomedical image analysis, video coding, motion segmentation, human-machine interface, visualization, medical imaging, traffic systems, satellite imaging etc. This framework focuses on the precise object tracking under deformation such as scaling, rotation, noise, blurring and change of illumination. This research is a trail to solve these serious problems in visual object tracking by which the quality of the overall system will be improved. Developing a three dimensional (3D) geometrical model to determine the current pose of an object and predict its future location based on FIR model learned by the OLS. This framework presents a robust ranging technique to track a visual target instead of the traditional expensive ranging sensors. The presented research work is applied to real video stream and achieved high

  14. Precision measurements of electroweak parameters

    CERN Document Server

    Savin, Alexander

    2017-01-01

    A set of selected precise measurements of the SM parameters from the LHC experiments is discussed. Results on W-mass measurement and forward-backward asymmetry in production of the Drell--Yan events in both dielectron and dimuon decay channels are presented together with results on the effective mixing angle measurements. Electroweak production of the vector bosons in association with two jets is discussed.

  15. Precision titration mini-calorimeter

    International Nuclear Information System (INIS)

    Ensor, D.; Kullberg, L.; Choppin, G.

    1977-01-01

    The design and test of a small volume calorimeter of high precision and simple design is described. The calorimeter operates with solution sample volumes in the range of 3 to 5 ml. The results of experiments on the entropy changes for two standard reactions: (1) reaction of tris(hydroxymethyl)aminomethane with hydrochloric acid and (2) reaction between mercury(II) and bromide ions are reported to confirm the accuracy and overall performance of the calorimeter

  16. LOFAR lightning imaging : mapping lightning with nanosecond precision

    NARCIS (Netherlands)

    Hare, B.M.; Scholten, O.; Bonardi, A.; Buitink, S.; Corstanje, A.; Ebert, U.; Falcke, H.; Hörandel, J.R.; Leijnse, H.; Mitra, P.; Mulrey, K.; Nelles, A.; Rachen, J. P.; Rossetto, L.; Rutjes, C.; Schellart, P.; Thoudam, S.; Trinh, T.N.G.; ter Veen, S.; Winchen, T.

    2018-01-01

    Lightning mapping technology has proven instrumental in understanding lightning. In this work we present a pipeline that can use lightning observed by the LOw-Frequency ARray (LOFAR) radio telescope to construct a 3-D map of the flash. We show that LOFAR has unparalleled precision, on the order of

  17. Radiation oncology in the era of precision medicine

    DEFF Research Database (Denmark)

    Baumann, Michael; Krause, Mechthild; Overgaard, Jens

    2016-01-01

    with preservation of health-related quality of life can be achieved in many patients. Two major strategies, acting synergistically, will enable further widening of the therapeutic window of radiation oncology in the era of precision medicine: technology-driven improvement of treatment conformity, including advanced...

  18. Calibração e validação de um medidor de capacitância num projecto de agriculturade precisão em pastagens Calibration and validation of an electronic capacitance meter in a pasture precision agriculture project

    Directory of Open Access Journals (Sweden)

    João Manuel Serrano

    2009-12-01

    Full Text Available O objectivo deste trabalho consistiu em calibrar uma sonda electrónica de capacitância para simplificar o processo de avaliação da pastagem num projecto de Agricultura de Precisão. O método tradicional de determinação da massa de pastagem exige um grande esforço e é incompatível com a gestão do dia a dia dos agricultores. Os ensaios foram realizados em diferentes datas do ano de 2007, em três explorações agrícolas, que representam as pastagens típicas do Alentejo (gramíneas; leguminosas; e mistura biodiversa. Foram utilizadas equações de regressão para relacionar a massa de matéria seca obtida na medição directa com as estimativas indirectas obtidas nas leituras de capacitância. Em dois dos três locais os coeficientes de determinação foram elevados, 0,90 nas gramíneas e entre 0,67 e 0,75 na mistura biodiversa. Nas leguminosas o coeficiente de determinação variou entre 0,27 e 0,59. Em 2008 as equações de previsão foram validadas em dois dos locais, tendo-se obtido um desvio entre a massa efectivamente cortada e a massa estimada igual ou inferior a 20%.The general objective of the study was calibrate an electronic capacitance meter to estimating the pasture dry matter in a precision agriculture project. The standard method of assessing pasture requires great effort and farmers are not willing to make this effort in day-to-day management of pastures. The field tests for carrying out in different dates of 2007 and in three dairy farms, represents the typical pastures in Alentejo region (grasses; leguminous; and bio divers mixture. Regression techniques are used to relate the weight of the herbage in kg of dry matter for hectare to the meter reading of capacitance. The estimation of dry matter of the herbage mass, in kg ha-1, based in capacitance was relatively good in two sites, with overall coefficients of determination of 0,90 in grasses and 0,67 to 0,75 in bio divers mixture. In the leguminous the coefficients of

  19. Validation of the model of Critical Heat Flux COBRA-TF compared experiments of Post-Dryout performed by the Royal Institute of Technology (KTH); Validacion del Modelo de Critical Heat Flux de COBRA-TF frente a los Experimentos de Post-Dryout realizados por el Royal Institute of Technology (KTH)

    Energy Technology Data Exchange (ETDEWEB)

    Abarca, A.; Miro, R.; Barrachina, T.; Verdu, G.

    2014-07-01

    In this work is a validation of the results obtained with different existing correlations for predicting the value and location of the CTF code CHF, using them for experiments of Post-Dryout conducted by the Royal Institute of Technology (KTH) in Stockholm, Sweden. (Author)

  20. Ultra-wideband ranging precision and accuracy

    International Nuclear Information System (INIS)

    MacGougan, Glenn; O'Keefe, Kyle; Klukas, Richard

    2009-01-01

    This paper provides an overview of ultra-wideband (UWB) in the context of ranging applications and assesses the precision and accuracy of UWB ranging from both a theoretical perspective and a practical perspective using real data. The paper begins with a brief history of UWB technology and the most current definition of what constitutes an UWB signal. The potential precision of UWB ranging is assessed using Cramer–Rao lower bound analysis. UWB ranging methods are described and potential error sources are discussed. Two types of commercially available UWB ranging radios are introduced which are used in testing. Actual ranging accuracy is assessed from line-of-sight testing under benign signal conditions by comparison to high-accuracy electronic distance measurements and to ranges derived from GPS real-time kinematic positioning. Range measurements obtained in outdoor testing with line-of-sight obstructions and strong reflection sources are compared to ranges derived from classically surveyed positions. The paper concludes with a discussion of the potential applications for UWB ranging

  1. Towards High Productivity in Precision Grinding

    Directory of Open Access Journals (Sweden)

    W. Brian Rowe

    2018-04-01

    Full Text Available Over the last century, substantial advances have been made, based on improved understanding of the requirements of grinding processes, machines, control systems, materials, abrasives, wheel preparation, coolants, lubricants, and coolant delivery. This paper reviews a selection of areas in which the application of scientific principles and engineering ingenuity has led to the development of new grinding processes, abrasives, tools, machines, and systems. Topics feature a selection of areas where relationships between scientific principles and new techniques are yielding improved productivity and better quality. These examples point towards further advances that can fruitfully be pursued. Applications in modern grinding technology range from high-precision kinematics for grinding very large lenses and reflectors through to medium size grinding machine processes and further down to grinding very small components used in micro electro-mechanical systems (MEMS devices. The importance of material issues is emphasized for the range of conventional engineering steels, through to aerospace materials, ceramics, and composites. It is suggested that future advances in productivity will include the wider application of artificial intelligence and robotics to improve precision, process efficiency, and features required to integrate grinding processes into wider manufacturing systems.

  2. Human genomics projects and precision medicine.

    Science.gov (United States)

    Carrasco-Ramiro, F; Peiró-Pastor, R; Aguado, B

    2017-09-01

    The completion of the Human Genome Project (HGP) in 2001 opened the floodgates to a deeper understanding of medicine. There are dozens of HGP-like projects which involve from a few tens to several million genomes currently in progress, which vary from having specialized goals or a more general approach. However, data generation, storage, management and analysis in public and private cloud computing platforms have raised concerns about privacy and security. The knowledge gained from further research has changed the field of genomics and is now slowly permeating into clinical medicine. The new precision (personalized) medicine, where genome sequencing and data analysis are essential components, allows tailored diagnosis and treatment according to the information from the patient's own genome and specific environmental factors. P4 (predictive, preventive, personalized and participatory) medicine is introducing new concepts, challenges and opportunities. This review summarizes current sequencing technologies, concentrates on ongoing human genomics projects, and provides some examples in which precision medicine has already demonstrated clinical impact in diagnosis and/or treatment.

  3. Precision diamond grinding of ceramics and glass

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.; Paul, H.; Scattergood, R.O.

    1988-12-01

    A new research initiative will be undertaken to investigate the effect of machine parameters and material properties on precision diamond grinding of ceramics and glass. The critical grinding depth to initiate the plastic flow-to-brittle fracture regime will be directly measured using plunge-grind tests. This information will be correlated with machine parameters such as wheel bonding and diamond grain size. Multiaxis grinding tests will then be made to provide data more closely coupled with production technology. One important aspect of the material property studies involves measuring fracture toughness at the very short crack sizes commensurate with grinding damage. Short crack toughness value`s can be much less than the long-crack toughness values measured in conventional fracture tests.

  4. Atomic physics precise measurements and ultracold matter

    CERN Document Server

    Inguscio, Massimo

    2013-01-01

    Atomic Physics provides an expert guide to two spectacular new landscapes in physics: precision measurements, which have been revolutionized by the advent of the optical frequency comb, and atomic physics, which has been revolutionized by laser cooling. These advances are not incremental but transformative: they have generated a consilience between atomic and many-body physics, precipitated an explosion of scientific and technological applications, opened new areas of research, and attracted a brilliant generation of younger scientists. The research is advancing so rapidly, the barrage of applications is so dazzling, that students can be bewildered. For both students and experienced scientists, this book provides an invaluable description of basic principles, experimental methods, and scientific applications.

  5. Weak gravitational lensing towards high-precision cosmology

    International Nuclear Information System (INIS)

    Berge, Joel

    2007-01-01

    This thesis aims at studying weak gravitational lensing as a tool for high-precision cosmology. We first present the development and validation of a precise and accurate tool for measuring gravitational shear, based on the shapelets formalism. We then use shapelets on real images for the first time, we analyze CFHTLS images, and combine them with XMM-LSS data. We measure the normalisation of the density fluctuations power spectrum σ 8 , and the one of the mass-temperature relation for galaxy clusters. The analysis of the Hubble space telescope COSMOS field confirms our σ 8 measurement and introduces tomography. Finally, aiming at optimizing future surveys, we compare the individual and combined merits of cluster counts and power spectrum tomography. Our results demonstrate that next generation surveys will allow weak lensing to yield its full potential in the high-precision cosmology era. (author) [fr

  6. FY 1999 Report on the results of technological development of machine tools for rationalization of energy utilization. Development of a lathe with high precision and conservation of energy using natural phenomenon (Thermal countermeasure using self compulsory cooling and thermal insensitive structure - results of the first year); 1999 nendo energy shiyo gorika kosaku kikai nado gijutsu kaihatsu seika hokokusho. Shizen gensho wo takumi ni oyoshita sho energy koseido senban no kaihatsu (self kyosei reikyaku to netsufukan gijutsu wo mochiita netsuhenkei yokusei taisaku - dai 1 nendo)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    A lathe, which is a central tool in a factory of automobiles or home electric appliances, tends to suffer decreased machining precision resulting from thermal deformation. This project is aimed at development of the energy-saving, high-precision lathe technologies using self compulsory cooling and thermal insensitive technologies as the countermeasures against the thermal deformation. The self compulsory cooling is a method of cooling by evaporation of water with an evaporative, water-absorptive cloth being bonded to a machine tool surface around the major axis. The thermal insensitive technologies include the three-dimensionally zero-center design technologies which help design a lathe in such a way to set the processing point (tool working point) at the base of thermal deformation in the X, Y and Z axis directions; material combination technologies to control thermal deformation; and coloring technologies to control thermal deformation. The development target is the high-precision lathe fabrication technologies, which realize a temporal precision change of 1 to 2 {mu}m or less per work dimension of 100mm. The activities cover 5 areas, including development of elementary technologies for each item and construction/evaluation of the full-size test unit. (NEDO)

  7. Defining precision: The precision medicine initiative trials NCI-MPACT and NCI-MATCH.

    Science.gov (United States)

    Coyne, Geraldine O'Sullivan; Takebe, Naoko; Chen, Alice P

    "Precision" trials, using rationally incorporated biomarker targets and molecularly selective anticancer agents, have become of great interest to both patients and their physicians. In the endeavor to test the cornerstone premise of precision oncotherapy, that is, determining if modulating a specific molecular aberration in a patient's tumor with a correspondingly specific therapeutic agent improves clinical outcomes, the design of clinical trials with embedded genomic characterization platforms which guide therapy are an increasing challenge. The National Cancer Institute Precision Medicine Initiative is an unprecedented large interdisciplinary collaborative effort to conceptualize and test the feasibility of trials incorporating sequencing platforms and large-scale bioinformatics processing that are not currently uniformly available to patients. National Cancer Institute-Molecular Profiling-based Assignment of Cancer Therapy and National Cancer Institute-Molecular Analysis for Therapy Choice are 2 genomic to phenotypic trials under this National Cancer Institute initiative, where treatment is selected according to predetermined genetic alterations detected using next-generation sequencing technology across a broad range of tumor types. In this article, we discuss the objectives and trial designs that have enabled the public-private partnerships required to complete the scale of both trials, as well as interim trial updates and strategic considerations that have driven data analysis and targeted therapy assignment, with the intent of elucidating further the benefits of this treatment approach for patients. Copyright © 2017. Published by Elsevier Inc.

  8. Constraining supersymmetry with precision data

    International Nuclear Information System (INIS)

    Pierce, D.M.; Erler, J.

    1997-01-01

    We discuss the results of a global fit to precision data in supersymmetric models. We consider both gravity- and gauge-mediated models. As the superpartner spectrum becomes light, the global fit to the data typically results in larger values of χ 2 . We indicate the regions of parameter space which are excluded by the data. We discuss the additional effect of the B(B→X s γ) measurement. Our analysis excludes chargino masses below M Z in the simplest gauge-mediated model with μ>0, with stronger constraints for larger values of tanβ. copyright 1997 American Institute of Physics

  9. High precision Standard Model Physics

    International Nuclear Information System (INIS)

    Magnin, J.

    2009-01-01

    The main goal of the LHCb experiment, one of the four large experiments of the Large Hadron Collider, is to try to give answers to the question of why Nature prefers matter over antimatter? This will be done by studying the decay of b quarks and their antimatter partners, b-bar, which will be produced by billions in 14 TeV p-p collisions by the LHC. In addition, as 'beauty' particles mainly decay in charm particles, an interesting program of charm physics will be carried on, allowing to measure quantities as for instance the D 0 -D-bar 0 mixing, with incredible precision.

  10. Electroweak precision measurements in CMS

    CERN Document Server

    Dordevic, Milos

    2017-01-01

    An overview of recent results on electroweak precision measurements from the CMS Collaboration is presented. Studies of the weak boson differential transverse momentum spectra, Z boson angular coefficients, forward-backward asymmetry of Drell-Yan lepton pairs and charge asymmetry of W boson production are made in comparison to the state-of-the-art Monte Carlo generators and theoretical predictions. The results show a good agreement with the Standard Model. As a proof of principle for future W mass measurements, a W-like analysis of the Z boson mass is performed.

  11. Precision proton spectrometers for CMS

    CERN Document Server

    Albrow, Michael

    2013-01-01

    We plan to add high precision tracking- and timing-detectors at z = +/- 240 m to CMS to study exclusive processes p + p -- p + X + p at high luminosity. This enables the LHC to be used as a tagged photon-photon collider, with X = l+l- and W+W-, and as a "tagged" gluon-gluon collider (with a spectator gluon) for QCD studies with jets. A second stage at z = 240 m would allow observations of exclusive Higgs boson production.

  12. Precise Analysis of String Expressions

    DEFF Research Database (Denmark)

    Christensen, Aske Simon; Møller, Anders; Schwartzbach, Michael Ignatieff

    2003-01-01

    We perform static analysis of Java programs to answer a simple question: which values may occur as results of string expressions? The answers are summarized for each expression by a regular language that is guaranteed to contain all possible values. We present several applications of this analysis...... are automatically produced. We present extensive benchmarks demonstrating that the analysis is efficient and produces results of useful precision......., including statically checking the syntax of dynamically generated expressions, such as SQL queries. Our analysis constructs flow graphs from class files and generates a context-free grammar with a nonterminal for each string expression. The language of this grammar is then widened into a regular language...

  13. The Many Faces of Precision

    Directory of Open Access Journals (Sweden)

    Andy eClark

    2013-05-01

    Full Text Available An appreciation of the many roles of ‘precision-weighting’ (upping the gain on select populations of prediction error units opens the door to better accounts of planning and ‘offline simulation’, makes suggestive contact with large bodies of work on embodied and situated cognition, and offers new perspectives on the ‘active brain’. Combined with the complex affordances of language and culture, and operating against the essential backdrop of a variety of more biologically basic ploys and stratagems, the result is a maximally context-sensitive, restless, constantly self-reconfiguring architecture.

  14. Inertially Stabilized Platforms for Precision Pointing Applications to Directed-Energy Weapons and Space-Based Lasers (Preprint)

    National Research Council Canada - National Science Library

    Negro, J; Griffin, S

    2006-01-01

    .... This article addresses directed-energy-weapon (DEW) precision pointing requirements and implementation alternatives in the context of strapdown and stable-platform inertial-reference technologies...

  15. High precision neutron polarization for PERC

    International Nuclear Information System (INIS)

    Klauser, C.

    2013-01-01

    The decay of the free neutron into a proton, an electron and an anti-electron neutrino offers a simple system to study the semi-leptonic weak decay. High precision measurements of angular correlation coefficients of this decay provide the opportunity to test the standard model on the low energy frontier. The Proton Electron Radiation Channel PERC is part of a new generation of expriments pushing the accuracy of such an angular correlation coefficient measurement towards 10 -4 . Past experiments have been limited to an accuracy of 10 -3 with uncertainties on the neutron polarization as one of the leading systematic errors. This thesis focuses on the development of a stable, highly precise neutron polarization for a large, divergent cold neutron beam. A diagnostic tool that provides polarization higher than 99.99 % and analyzes with an accuracy of 10 -4 , the Opaque Test Bench, is presented and validated. It consists of two highly opaque polarized helium cells. The Opaque Test Bench reveals depolarizing effects in polarizing supermirrors commonly used for polarization in neutron decay experiments. These effects are investigated in detail. They are due to imperfect lateral magnetization in supermirror layers and can be minimized by significantly increased magnetizing fields and low incidence angle and supermirror factor m. A subsequent test in the crossed (X-SM) geometry demonstrated polarizations up to 99.97% from supermirrors only, improving neutron polarization with supermirrors by an order of magnitude. The thesis also discusses other neutron optical components of the PERC beamline: Monte-Carlo simulations of the beamline under consideration of the primary guide are carried out. In addition, calculation shows that PERC would statistically profit from an installation at the European Spallation source. Furthermore, beamline components were tested. A radio-frequency spin flipper was confirmed to work with an efficiency higher than 0.9999. (author) [de

  16. Precision luminosity measurements at LHCb

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Brown, Henry; Bursche, Albert; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cojocariu, Lucian; Collazuol, Gianmaria; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gascon, David; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Geraci, Angelo; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Gianì, Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Lohn, Stefan; Longstaff, Iain; Lopes, Jose; Lopez-March, Neus; Lowdon, Peter; Lu, Haiting; Lucchesi, Donatella; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Maurin, Brice; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Moggi, Niccolò; Molina Rodriguez, Josue; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Pessina, Gianluigi; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz, Hugo; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schubiger, Maxime; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiedner, Dirk; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilschut, Hans; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Xu, Zhirui; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2014-12-05

    Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy $\\sqrt{s}$. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for $\\sqrt{s}$ = 2.76, 7 and 8 TeV (proton-proton collisions) and for $\\sqrt{s_{NN}}$ = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at $\\sqrt{s}$ = 8 TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determin...

  17. Precision experiments in electroweak interactions

    International Nuclear Information System (INIS)

    Swartz, M.L.

    1990-03-01

    The electroweak theory of Glashow, Weinberg, and Salam (GWS) has become one of the twin pillars upon which our understanding of all particle physics phenomena rests. It is a brilliant achievement that qualitatively and quantitatively describes all of the vast quantity of experimental data that have been accumulated over some forty years. Note that the word quantitatively must be qualified. The low energy limiting cases of the GWS theory, Quantum Electrodynamics and the V-A Theory of Weak Interactions, have withstood rigorous testing. The high energy synthesis of these ideas, the GWS theory, has not yet been subjected to comparably precise scrutiny. The recent operation of a new generation of proton-antiproton (p bar p) and electron-positron (e + e - ) colliders has made it possible to produce and study large samples of the electroweak gauge bosons W ± and Z 0 . We expect that these facilities will enable very precise tests of the GWS theory to be performed in the near future. In keeping with the theme of this Institute, Physics at the 100 GeV Mass Scale, these lectures will explore the current status and the near-future prospects of these experiments

  18. Antihydrogen production and precision experiments

    International Nuclear Information System (INIS)

    Nieto, M.M.; Goldman, T.; Holzscheiter, M.H.

    1996-01-01

    The study of CPT invariance with the highest achievable precision in all particle sectors is of fundamental importance for physics. Equally important is the question of the gravitational acceleration of antimatter. In recent years, impressive progress has been achieved in capturing antiprotons in specially designed Penning traps, in cooling them to energies of a few milli-electron volts, and in storing them for hours in a small volume of space. Positrons have been accumulated in large numbers in similar traps, and low energy positron or positronium beams have been generated. Finally, steady progress has been made in trapping and cooling neutral atoms. Thus the ingredients to form antihydrogen at rest are at hand. Once antihydrogen atoms have been captured at low energy, spectroscopic methods can be applied to interrogate their atomic structure with extremely high precision and compare it to its normal matter counterpart, the hydrogen atom. Especially the 1S-2S transition, with a lifetime of the excited state of 122 msec and thereby a natural linewidth of 5 parts in 10 16 , offers in principle the possibility to directly compare matter and antimatter properties at a level of 1 part in 10 16

  19. Development of a sensor node for precision horticulture.

    Science.gov (United States)

    López, Juan A; Soto, Fulgencio; Sánchez, Pedro; Iborra, Andrés; Suardiaz, Juan; Vera, Juan A

    2009-01-01

    This paper presents the design of a new wireless sensor node (GAIA Soil-Mote) for precision horticulture applications which permits the use of precision agricultural instruments based on the SDI-12 standard. Wireless communication is achieved with a transceiver compliant with the IEEE 802.15.4 standard. The GAIA Soil-Mote software implementation is based on TinyOS. A two-phase methodology was devised to validate the design of this sensor node. The first phase consisted of laboratory validation of the proposed hardware and software solution, including a study on power consumption and autonomy. The second phase consisted of implementing a monitoring application in a real broccoli (Brassica oleracea L. var Marathon) crop in Campo de Cartagena in south-east Spain. In this way the sensor node was validated in real operating conditions. This type of application was chosen because there is a large potential market for it in the farming sector, especially for the development of precision agriculture applications.

  20. Development of a Sensor Node for Precision Horticulture

    Science.gov (United States)

    López, Juan A.; Soto, Fulgencio; Sánchez, Pedro; Iborra, Andrés; Suardiaz, Juan; Vera, Juan A.

    2009-01-01

    This paper presents the design of a new wireless sensor node (GAIA Soil-Mote) for precision horticulture applications which permits the use of precision agricultural instruments based on the SDI-12 standard. Wireless communication is achieved with a transceiver compliant with the IEEE 802.15.4 standard. The GAIA Soil-Mote software implementation is based on TinyOS. A two-phase methodology was devised to validate the design of this sensor node. The first phase consisted of laboratory validation of the proposed hardware and software solution, including a study on power consumption and autonomy. The second phase consisted of implementing a monitoring application in a real broccoli (Brassica oleracea L. var Marathon) crop in Campo de Cartagena in south-east Spain. In this way the sensor node was validated in real operating conditions. This type of application was chosen because there is a large potential market for it in the farming sector, especially for the development of precision agriculture applications. PMID:22412309

  1. Precision medicine in pediatric oncology: Lessons learned and next steps

    Science.gov (United States)

    Mody, Rajen J.; Prensner, John R.; Everett, Jessica; Parsons, D. Williams; Chinnaiyan, Arul M.

    2017-01-01

    The maturation of genomic technologies has enabled new discoveries in disease pathogenesis as well as new approaches to patient care. In pediatric oncology, patients may now receive individualized genomic analysis to identify molecular aberrations of relevance for diagnosis and/or treatment. In this context, several recent clinical studies have begun to explore the feasibility and utility of genomics-driven precision medicine. Here, we review the major developments in this field, discuss current limitations, and explore aspects of the clinical implementation of precision medicine, which lack consensus. Lastly, we discuss ongoing scientific efforts in this arena, which may yield future clinical applications. PMID:27748023

  2. Public health and precision medicine share a goal.

    Science.gov (United States)

    Vaithinathan, Asokan G; Asokan, Vanitha

    2017-05-01

    The advances made in genomics and molecular tools aid public health programs in the investigation of outbreaks and control of diseases by taking advantage of the precision medicine. Precision medicine means "segregating the individuals into subpopulations who vary in their disease susceptibility and response to a precise treatment" and not merely designing of drugs or creation of medical devices. By 2017, the United Kingdom 100,000 Genomes Project is expected to sequence 100,000 genomes from 70,000 patients. Similarly, the Precision Medicine Initiative of the United States plans to increase population-based genome sequencing and link it with clinical data. A national cohort of around 1 million people is to be established in the long term, to investigate the genetic and environmental determinants of health and disease, and further integrated to their electronic health records that are optional. Precision public health can be seen as administering the right intervention to the needy population at an appropriate time. Precision medicine originates from a wet-lab while evidence-based medicine is nurtured in a clinic. Linking the quintessential basic science research and clinical practice is necessary. In addition, new technologies to employ and analyze data in an integrated and dynamic way are essential for public health and precision medicine. The transition from evidence-based approach in public health to genomic approach to individuals with a paradigm shift of a "reactive" medicine to a more "proactive" and personalized health care may sound exceptional. However, a population perspective is needed for the precision medicine to succeed. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.

  3. The European Society for Medical Oncology (ESMO) Precision Medicine Glossary.

    Science.gov (United States)

    Yates, L R; Seoane, J; Le Tourneau, C; Siu, L L; Marais, R; Michiels, S; Soria, J C; Campbell, P; Normanno, N; Scarpa, A; Reis-Filho, J S; Rodon, J; Swanton, C; Andre, F

    2018-01-01

    Precision medicine is rapidly evolving within the field of oncology and has brought many new concepts and terminologies that are often poorly defined when first introduced, which may subsequently lead to miscommunication within the oncology community. The European Society for Medical Oncology (ESMO) recognises these challenges and is committed to support the adoption of precision medicine in oncology. To add clarity to the language used by oncologists and basic scientists within the context of precision medicine, the ESMO Translational Research and Personalised Medicine Working Group has developed a standardised glossary of relevant terms. Relevant terms for inclusion in the glossary were identified via an ESMO member survey conducted in Autumn 2016, and by the ESMO Translational Research and Personalised Medicine Working Group members. Each term was defined by experts in the field, discussed and, if necessary, modified by the Working Group before reaching consensus approval. A literature search was carried out to determine which of the terms, 'precision medicine' and 'personalised medicine', is most appropriate to describe this field. A total of 43 terms are included in the glossary, grouped into five main themes-(i) mechanisms of decision, (ii) characteristics of molecular alterations, (iii) tumour characteristics, (iv) clinical trials and statistics and (v) new research tools. The glossary classes 'precision medicine' or 'personalised medicine' as technically interchangeable but the term 'precision medicine' is favoured as it more accurately reflects the highly precise nature of new technologies that permit base pair resolution dissection of cancer genomes and is less likely to be misinterpreted. The ESMO Precision Medicine Glossary provides a resource to facilitate consistent communication in this field by clarifying and raising awareness of the language employed in cancer research and oncology practice. The glossary will be a dynamic entity, undergoing

  4. About the problems and perspectives of making precision compressor blades

    Directory of Open Access Journals (Sweden)

    V. E. Galiev

    2014-01-01

    Full Text Available The problems of manufacturing blades with high precision profile geometry are considered in the article. The variant of the technology under development rules out the use of mechanical processing methods for blades airfoil. The article consists of an introduction and six small sections.The introduction sets out the requirements for modern aircraft engines, makes a list of problems arisen in the process of their manufacturing, and marks the relevance of the work.The first section analyzes the existing technology of precision blades. There is an illustration reflecting the stages of the process. Their advantages and disadvantages are marked.The second section provides an illustration, which shows the system-based blades used in the manufacturing process and a model of the work piece using the technology being developed. An analysis of each basing scheme is presented.In the third section we list the existing control methods of geometrical parameters of blades airfoil and present the measurement error data of devices. The special attention is paid to the impossibility to control the accuracy of geometrical parameters of precision blades.The fourth section presents the advantages of the electrochemical machining method with a consistent vibration of tool-electrode and with feeding the pulses of technology current over the traditional method. The article presents data accuracy and surface roughness of the blades airfoil reached owing to precision electrochemical machining. It illustrates machines that implement the given method of processing and components manufactured on them.The fifth section describes the steps of the developed process with justification for the use of the proposed operations.Based on the analysis, the author argues that the application of the proposed process to manufacture the precision compressor blades ensures producing the items that meet the requirements of the drawing.

  5. Design of precision position adjustable scoop

    International Nuclear Information System (INIS)

    Li Zhili; Zhang Kai; Dong Jinping

    2014-01-01

    In isotopes separation technologies, the centrifuge method has been the most popular technology now. Separation performance of centrifugal machines is greatly influenced by the flow field in the centrifugal machines. And the position of scoops in the centrifuges has a significant influence on the flow field. To obtain a better flow field characteristic and find the best position of scoops in the centrifuges, a position adjustable scoop system was studied. A micro stage and a linear encoder were used in the system to improve the position accuracy of the scoop. Eddy current sensors had been used in a position calibration measurement. The measurement result showed the sensitivity and stability of the position system could meet the performance expectation. But as the driving mean, the steel wire and pulley limit the control precision. On the basis of this scheme, an ultrasonic motor was used as driving mean. Experimental results showed the control accuracy was improved. This scheme laid a foundation to obtain internal flow field parameters of centrifuge and get the optimal feeding tube position. (authors)

  6. Pharmacogenetics of asthma: toward precision medicine.

    Science.gov (United States)

    Kersten, Elin T G; Koppelman, Gerard H

    2017-01-01

    Although currently available drugs to treat asthma are effective in most patients, a proportion of patients do not respond or experience side-effects; which is partly genetically determined. Pharmacogenetics is the study of how genetic variations influence drug response. In this review, we summarize prior results and recent studies in pharmacogenetics to determine if we can use genetic profiles for personalized treatment of asthma. The field of pharmacogenetics has moved from candidate gene studies in single populations toward genome-wide association studies and meta-analysis of multiple studies. New technologies have been used to enrich results, and an expanding number of genetic loci have been associated with therapeutic responses to asthma drugs. Prospective, genotype-stratified treatment studies have been conducted for β2-agonists, showing attenuated response in children carrying the Arg16 variant in the β2-adrenoreceptor gene. Although there has been much progress, many findings have not been replicated and currently known genetic loci only account for a fraction of variability in drug response. More research is necessary to translate into clinical practice. A polygenic predictive approach integrated in complex networks with other 'omics' technologies could aid to achieve this goal. Finally, to change clinical practice, studies that compare precision medicine with traditional medicine are needed.

  7. Streamlining Transportation Corridors Planning Processes and Validating the Application of Commercial Remote Sensing and Spatial Information (CRS-SI) Technologies for Environmental Impact Assessments

    Science.gov (United States)

    2008-02-05

    The new US DOT RITA program has selected MSU for addressing corridor planning and environmental assessment in new and innovative ways that can be compared to traditional approaches. Our primary focus is on the application and validation of new and in...

  8. Evaluation and validation of a multi-residue method based on biochip technology for the simultaneous screening of six families of antibiotics in muscle and aquaculture products.

    Science.gov (United States)

    Gaudin, Valérie; Hedou, Celine; Soumet, Christophe; Verdon, Eric

    2016-01-01

    The Evidence Investigator™ system (Randox, UK) is a biochip and semi-automated system. The microarray kit II (AM II) is capable of detecting several compounds belonging to different families of antibiotics: quinolones, ceftiofur, thiamphenicol, streptomycin, tylosin and tetracyclines. The performance of this innovative system was evaluated for the detection of antibiotic residues in new matrices, in muscle of different animal species and in aquaculture products. The method was validated according to the European Decision No. EC/2002/657 and the European guideline for the validation of screening methods, which represents a complete initial validation. The false-positive rate was equal to 0% in muscle and in aquaculture products. The detection capabilities CCβ for 12 validated antibiotics (enrofloxacin, difloxacin, ceftiofur, desfuroyl ceftiofur cysteine disulfide, thiamphenicol, florfenicol, tylosin, tilmicosin, streptomycin, dihydrostreptomycin, tetracycline, doxycycline) were all lower than the respective maximum residue limits (MRLs) in muscle from different animal origins (bovine, ovine, porcine, poultry). No cross-reactions were observed with other antibiotics, neither with the six detected families nor with other families of antibiotics. The AM II kit could be applied to aquaculture products but with higher detection capabilities from those in muscle. The detection capabilities CCβ in aquaculture products were respectively at 0.25, 0.10 and 0.5 of the respective MRL in aquaculture products for enrofloxacin, tylosin and oxytetracycline. The performance of the AM II kit has been compared with other screening methods and with the performance characteristics previously determined in honey.

  9. Evaluation of the Terminal Precision Scheduling and Spacing System for Near-Term NAS Application

    Science.gov (United States)

    Thipphavong, Jane; Martin, Lynne Hazel; Swenson, Harry N.; Lin, Paul; Nguyen, Jimmy

    2012-01-01

    NASA has developed a capability for terminal area precision scheduling and spacing (TAPSS) to provide higher capacity and more efficiently manage arrivals during peak demand periods. This advanced technology is NASA's vision for the NextGen terminal metering capability. A set of human-in-the-loop experiments was conducted to evaluate the performance of the TAPSS system for near-term implementation. The experiments evaluated the TAPSS system under the current terminal routing infrastructure to validate operational feasibility. A second goal of the study was to measure the benefit of the Center and TRACON advisory tools to help prioritize the requirements for controller radar display enhancements. Simulation results indicate that using the TAPSS system provides benefits under current operations, supporting a 10% increase in airport throughput. Enhancements to Center decision support tools had limited impact on improving the efficiency of terminal operations, but did provide more fuel-efficient advisories to achieve scheduling conformance within 20 seconds. The TRACON controller decision support tools were found to provide the most benefit, by improving the precision in schedule conformance to within 20 seconds, reducing the number of arrivals having lateral path deviations by 50% and lowering subjective controller workload. Overall, the TAPSS system was found to successfully develop an achievable terminal arrival metering plan that was sustainable under heavy traffic demand levels and reduce the complexity of terminal operations when coupled with the use of the terminal controller advisory tools.

  10. Learning-based computing techniques in geoid modeling for precise height transformation

    Science.gov (United States)

    Erol, B.; Erol, S.

    2013-03-01

    Precise determination of local geoid is of particular importance for establishing height control in geodetic GNSS applications, since the classical leveling technique is too laborious. A geoid model can be accurately obtained employing properly distributed benchmarks having GNSS and leveling observations using an appropriate computing algorithm. Besides the classical multivariable polynomial regression equations (MPRE), this study attempts an evaluation of learning based computing algorithms: artificial neural networks (ANNs), adaptive network-based fuzzy inference system (ANFIS) and especially the wavelet neural networks (WNNs) approach in geoid surface approximation. These algorithms were developed parallel to advances in computer technologies and recently have been used for solving complex nonlinear problems of many applications. However, they are rather new in dealing with precise modeling problem of the Earth gravity field. In the scope of the study, these methods were applied to Istanbul GPS Triangulation Network data. The performances of the methods were assessed considering the validation results of the geoid models at the observation points. In conclusion the ANFIS and WNN revealed higher prediction accuracies compared to ANN and MPRE methods. Beside the prediction capabilities, these methods were also compared and discussed from the practical point of view in conclusions.

  11. The Precision Field Lysimeter Concept

    Science.gov (United States)

    Fank, J.

    2009-04-01

    The understanding and interpretation of leaching processes have improved significantly during the past decades. Unlike laboratory experiments, which are mostly performed under very controlled conditions (e.g. homogeneous, uniform packing of pre-treated test material, saturated steady-state flow conditions, and controlled uniform hydraulic conditions), lysimeter experiments generally simulate actual field conditions. Lysimeters may be classified according to different criteria such as type of soil block used (monolithic or reconstructed), drainage (drainage by gravity or vacuum or a water table may be maintained), or weighing or non-weighing lysimeters. In 2004 experimental investigations have been set up to assess the impact of different farming systems on groundwater quality of the shallow floodplain aquifer of the river Mur in Wagna (Styria, Austria). The sediment is characterized by a thin layer (30 - 100 cm) of sandy Dystric Cambisol and underlying gravel and sand. Three precisely weighing equilibrium tension block lysimeters have been installed in agricultural test fields to compare water flow and solute transport under (i) organic farming, (ii) conventional low input farming and (iii) extensification by mulching grass. Specific monitoring equipment is used to reduce the well known shortcomings of lysimeter investigations: The lysimeter core is excavated as an undisturbed monolithic block (circular, 1 m2 surface area, 2 m depth) to prevent destruction of the natural soil structure, and pore system. Tracing experiments have been achieved to investigate the occurrence of artificial preferential flow and transport along the walls of the lysimeters. The results show that such effects can be neglected. Precisely weighing load cells are used to constantly determine the weight loss of the lysimeter due to evaporation and transpiration and to measure different forms of precipitation. The accuracy of the weighing apparatus is 0.05 kg, or 0.05 mm water equivalent

  12. Precision pharmacology for Alzheimer's disease.

    Science.gov (United States)

    Hampel, Harald; Vergallo, Andrea; Aguilar, Lisi Flores; Benda, Norbert; Broich, Karl; Cuello, A Claudio; Cummings, Jeffrey; Dubois, Bruno; Federoff, Howard J; Fiandaca, Massimo; Genthon, Remy; Haberkamp, Marion; Karran, Eric; Mapstone, Mark; Perry, George; Schneider, Lon S; Welikovitch, Lindsay A; Woodcock, Janet; Baldacci, Filippo; Lista, Simone

    2018-04-01

    The complex multifactorial nature of polygenic Alzheimer's disease (AD) presents significant challenges for drug development. AD pathophysiology is progressing in a non-linear dynamic fashion across multiple systems levels - from molecules to organ systems - and through adaptation, to compensation, and decompensation to systems failure. Adaptation and compensation maintain homeostasis: a dynamic equilibrium resulting from the dynamic non-linear interaction between genome, epigenome, and environment. An individual vulnerability to stressors exists on the basis of individual triggers, drivers, and thresholds accounting for the initiation and failure of adaptive and compensatory responses. Consequently, the distinct pattern of AD pathophysiology in space and time must be investigated on the basis of the individual biological makeup. This requires the implementation of systems biology and neurophysiology to facilitate Precision Medicine (PM) and Precision Pharmacology (PP). The regulation of several processes at multiple levels of complexity from gene expression to cellular cycle to tissue repair and system-wide network activation has different time delays (temporal scale) according to the affected systems (spatial scale). The initial failure might originate and occur at every level potentially affecting the whole dynamic interrelated systems within an organism. Unraveling the spatial and temporal dynamics of non-linear pathophysiological mechanisms across the continuum of hierarchical self-organized systems levels and from systems homeostasis to systems failure is key to understand AD. Measuring and, possibly, controlling space- and time-scaled adaptive and compensatory responses occurring during AD will represent a crucial step to achieve the capacity to substantially modify the disease course and progression at the best suitable timepoints, thus counteracting disrupting critical pathophysiological inputs. This approach will provide the conceptual basis for effective

  13. Precision cosmology and the landscape

    International Nuclear Information System (INIS)

    Bousso, Raphael; Bousso, Raphael

    2006-01-01

    After reviewing the cosmological constant problem--why is Lambda not huge?--I outline the two basic approaches that had emerged by the late 1980s, and note that each made a clear prediction. Precision cosmological experiments now indicate that the cosmological constant is nonzero. This result strongly favors the environmental approach, in which vacuum energy can vary discretely among widely separated regions in the universe. The need to explain this variation from first principles constitutes an observational constraint on fundamental theory. I review arguments that string theory satisfies this constraint, as it contains a dense discretuum of metastable vacua. The enormous landscape of vacua calls for novel, statistical methods of deriving predictions, and it prompts us to reexamine our description of spacetime on the largest scales. I discuss the effects of cosmological dynamics, and I speculate that weighting vacua by their entropy production may allow for prior-free predictions that do not resort to explicitly anthropic arguments

  14. GPS Precision Timing at CERN

    CERN Document Server

    Beetham, C G

    1999-01-01

    For the past decade, the Global Positioning System (GPS) has been used to provide precise time, frequency and position co-ordinates world-wide. Recently, equipment has become available specialising in providing extremely accurate timing information, referenced to Universal Time Co-ordinates (UTC). This feature has been used at CERN to provide time of day information for systems that have been installed in the Proton Synchrotron (PS), Super Proton Synchrotron (SPS) and the Large Electron Positron (LEP) machines. The different systems are described as well as the planned developments, particularly with respect to optical transmission and the Inter-Range Instrumentation Group IRIG-B standard, for future use in the Large Hadron Collider (LHC).

  15. FACTAR validation

    International Nuclear Information System (INIS)

    Middleton, P.B.; Wadsworth, S.L.; Rock, R.C.; Sills, H.E.; Langman, V.J.

    1995-01-01

    A detailed strategy to validate fuel channel thermal mechanical behaviour codes for use of current power reactor safety analysis is presented. The strategy is derived from a validation process that has been recently adopted industry wide. Focus of the discussion is on the validation plan for a code, FACTAR, for application in assessing fuel channel integrity safety concerns during a large break loss of coolant accident (LOCA). (author)

  16. A Retrospective Analysis of Precision Medicine Outcomes in Patients With Advanced Cancer Reveals Improved Progression-Free Survival Without Increased Health Care Costs.

    Science.gov (United States)

    Haslem, Derrick S; Van Norman, S Burke; Fulde, Gail; Knighton, Andrew J; Belnap, Tom; Butler, Allison M; Rhagunath, Sharanya; Newman, David; Gilbert, Heather; Tudor, Brian P; Lin, Karen; Stone, Gary R; Loughmiller, David L; Mishra, Pravin J; Srivastava, Rajendu; Ford, James M; Nadauld, Lincoln D

    2017-02-01

    The advent of genomic diagnostic technologies such as next-generation sequencing has recently enabled the use of genomic information to guide targeted treatment in patients with cancer, an approach known as precision medicine. However, clinical outcomes, including survival and the cost of health care associated with precision cancer medicine, have been challenging to measure and remain largely unreported. We conducted a matched cohort study of 72 patients with metastatic cancer of diverse subtypes in the setting of a large, integrated health care delivery system. We analyzed the outcomes of 36 patients who received genomic testing and targeted therapy (precision cancer medicine) between July 1, 2013, and January 31, 2015, compared with 36 historical control patients who received standard chemotherapy (n = 29) or best supportive care (n = 7). The average progression-free survival was 22.9 weeks for the precision medicine group and 12.0 weeks for the control group ( P = .002) with a hazard ratio of 0.47 (95% CI, 0.29 to 0.75) when matching on age, sex, histologic diagnosis, and previous lines of treatment. In a subset analysis of patients who received all care within the Intermountain Healthcare system (n = 44), per patient charges per week were $4,665 in the precision treatment group and $5,000 in the control group ( P = .126). These findings suggest that precision cancer medicine may improve survival for patients with refractory cancer without increasing health care costs. Although the results of this study warrant further validation, this precision medicine approach may be a viable option for patients with advanced cancer.

  17. Precise Plan in the analysis of volume precision in SynergyTM conebeam CT image

    International Nuclear Information System (INIS)

    Bai Sen; Xu Qingfeng; Zhong Renming; Jiang Xiaoqin; Jiang Qingfeng; Xu Feng

    2007-01-01

    Objective: A method of checking the volume precision in Synergy TM conebeam CT image. Methods: To scan known phantoms (big, middle, small spheres, cubes and cuniform cavum) at different positions (CBCT centre and departure centre from 5, 8, 10 cm along the accelerator G-T way)with conebeam CT, the phantom volume of reconstructed images were measure. Then to compared measured volume of Synergy TM conebeam CT with fanbeam CT results and nominal values. Results: The middle spheres had 1.5% discrepancy in nominal values and metrical average values at CBCT centre and departure from centre 5, 8 cm along accelerator G-T way. The small spheres showed 8.1%, with 0.8 % of the big cube and 2.9% of small cube, in nominal values and metrical average values at CBCT centre and departure from centre 5, 8, 10 cm along the accelerator G-T way. Conclusion: In valid scan range of Synergy TM conebeam CT, reconstructed precision is independent of the distance deviation from the center. (authors)

  18. Integrative methods for analyzing big data in precision medicine.

    Science.gov (United States)

    Gligorijević, Vladimir; Malod-Dognin, Noël; Pržulj, Nataša

    2016-03-01

    We provide an overview of recent developments in big data analyses in the context of precision medicine and health informatics. With the advance in technologies capturing molecular and medical data, we entered the area of "Big Data" in biology and medicine. These data offer many opportunities to advance precision medicine. We outline key challenges in precision medicine and present recent advances in data integration-based methods to uncover personalized information from big data produced by various omics studies. We survey recent integrative methods for disease subtyping, biomarkers discovery, and drug repurposing, and list the tools that are available to domain scientists. Given the ever-growing nature of these big data, we highlight key issues that big data integration methods will face. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Motion and gravity effects in the precision of quantum clocks.

    Science.gov (United States)

    Lindkvist, Joel; Sabín, Carlos; Johansson, Göran; Fuentes, Ivette

    2015-05-19

    We show that motion and gravity affect the precision of quantum clocks. We consider a localised quantum field as a fundamental model of a quantum clock moving in spacetime and show that its state is modified due to changes in acceleration. By computing the quantum Fisher information we determine how relativistic motion modifies the ultimate bound in the precision of the measurement of time. While in the absence of motion the squeezed vacuum is the ideal state for time estimation, we find that it is highly sensitive to the motion-induced degradation of the quantum Fisher information. We show that coherent states are generally more resilient to this degradation and that in the case of very low initial number of photons, the optimal precision can be even increased by motion. These results can be tested with current technology by using superconducting resonators with tunable boundary conditions.

  20. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  1. Using Big Data Analytics to Advance Precision Radiation Oncology.

    Science.gov (United States)

    McNutt, Todd R; Benedict, Stanley H; Low, Daniel A; Moore, Kevin; Shpitser, Ilya; Jiang, Wei; Lakshminarayanan, Pranav; Cheng, Zhi; Han, Peijin; Hui, Xuan; Nakatsugawa, Minoru; Lee, Junghoon; Moore, Joseph A; Robertson, Scott P; Shah, Veeraj; Taylor, Russ; Quon, Harry; Wong, John; DeWeese, Theodore

    2018-06-01

    Big clinical data analytics as a primary component of precision medicine is discussed, identifying where these emerging tools fit in the spectrum of genomics and radiomics research. A learning health system (LHS) is conceptualized that uses clinically acquired data with machine learning to advance the initiatives of precision medicine. The LHS is comprehensive and can be used for clinical decision support, discovery, and hypothesis derivation. These developing uses can positively impact the ultimate management and therapeutic course for patients. The conceptual model for each use of clinical data, however, is different, and an overview of the implications is discussed. With advancements in technologies and culture to improve the efficiency, accuracy, and breadth of measurements of the patient condition, the concept of an LHS may be realized in precision radiation therapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Perspectives of precision agriculture in a broader policy context

    DEFF Research Database (Denmark)

    Lind, Kim Martin Hjorth; Pedersen, Søren Marcus

    2017-01-01

    that in a precise and targeted approach reduce resource use and increase yield. Furthermore, the growing demand for higher value food products in terms of health and quality require traceability and information about production processes and resource use, which also correspond with the possibilities offered...... by precision agriculture technology. The general movement towards higher integration in food supply chains is a natural extension of the requirements for traceability and product information, which are integral parts of precision agriculture.......Agriculture is faced with contrasting requirements from the broader society. On the one hand, agriculture needs to expand production to be able to feed a growing global population. Furthermore, the developing bio-economy requires agriculture to produce for a range of non-food objectives such as bio...

  3. Precision kaon and hadron physics with KLOE

    International Nuclear Information System (INIS)

    Bossi, F.; De Lucia, E.; Lee-Franzini, J.; Miscetti, S.; Palutan, M.

    2008-01-01

    We describe the KLOE detector at DAΦNE, the Frascati φ, and its physics program. We begin with a brief description of the detector design and operation. Kaon physics is a major topic of investigation with KLOE thanks in part to the unique availability of pure K S , K L , K ± beams at a φ. We have measured all significant branching ratios of all kaon species, the K L and K ± lifetimes and the K → π form factor's t dependence. From the measurements we verify the validity of Cabibbo unitarity and lepton universality. We have studied properties of light scalar and pseudoscalar mesons with unprecedented accuracy. We have measured the e + e - → π + π - cross-section necessary for computing the major part of the hadronic contribution to the muon anomaly. The methods employed in all the above measurements as well as the φ leptonic width, precision mass measurements and searches for forbidden or extremely rare decays of kaons and η-mesons arc described. The impact of our results on flavor and hadron physics to date, as well as an outlook for further improvement in the near future, are discussed

  4. Precision Electrophile Tagging in Caenorhabditis elegans.

    Science.gov (United States)

    Long, Marcus J C; Urul, Daniel A; Chawla, Shivansh; Lin, Hong-Yu; Zhao, Yi; Haegele, Joseph A; Wang, Yiran; Aye, Yimon

    2018-01-16

    Adduction of an electrophile to privileged sensor proteins and the resulting phenotypically dominant responses are increasingly appreciated as being essential for metazoan health. Functional similarities between the biological electrophiles and electrophilic pharmacophores commonly found in covalent drugs further fortify the translational relevance of these small-molecule signals. Genetically encodable or small-molecule-based fluorescent reporters and redox proteomics have revolutionized the observation and profiling of cellular redox states and electrophile-sensor proteins, respectively. However, precision mapping between specific redox-modified targets and specific responses has only recently begun to be addressed, and systems tractable to both genetic manipulation and on-target redox signaling in vivo remain largely limited. Here we engineer transgenic Caenorhabditis elegans expressing functional HaloTagged fusion proteins and use this system to develop a generalizable light-controlled approach to tagging a prototypical electrophile-sensor protein with native electrophiles in vivo. The method circumvents issues associated with low uptake/distribution and toxicity/promiscuity. Given the validated success of C. elegans in aging studies, this optimized platform offers a new lens with which to scrutinize how on-target electrophile signaling influences redox-dependent life span regulation.

  5. Development of sensor guided precision sprayers

    NARCIS (Netherlands)

    Nieuwenhuizen, A.T.; Zande, van de J.C.

    2013-01-01

    Sensor guided precision sprayers were developed to automate the spray process with a focus on emission reduction and identical or increased efficacy, with the precision agriculture concept in mind. Within the project “Innovations2” sensor guided precision sprayers were introduced to leek,

  6. Micro Machining Enhances Precision Fabrication

    Science.gov (United States)

    2007-01-01

    Advanced thermal systems developed for the Space Station Freedom project are now in use on the International Space Station. These thermal systems employ evaporative ammonia as their coolant, and though they employ the same series of chemical reactions as terrestrial refrigerators, the space-bound coolers are significantly smaller. Two Small Business Innovation Research (SBIR) contracts between Creare Inc. of Hanover, NH and Johnson Space Center developed an ammonia evaporator for thermal management systems aboard Freedom. The principal investigator for Creare Inc., formed Mikros Technologies Inc. to commercialize the work. Mikros Technologies then developed an advanced form of micro-electrical discharge machining (micro-EDM) to make tiny holes in the ammonia evaporator. Mikros Technologies has had great success applying this method to the fabrication of micro-nozzle array systems for industrial ink jet printing systems. The company is currently the world leader in fabrication of stainless steel micro-nozzles for this market, and in 2001 the company was awarded two SBIR research contracts from Goddard Space Flight Center to advance micro-fabrication and high-performance thermal management technologies.

  7. Precision production: enabling deterministic throughput for precision aspheres with MRF

    Science.gov (United States)

    Maloney, Chris; Entezarian, Navid; Dumas, Paul

    2017-10-01

    Aspherical lenses offer advantages over spherical optics by improving image quality or reducing the number of elements necessary in an optical system. Aspheres are no longer being used exclusively by high-end optical systems but are now replacing spherical optics in many applications. The need for a method of production-manufacturing of precision aspheres has emerged and is part of the reason that the optics industry is shifting away from artisan-based techniques towards more deterministic methods. Not only does Magnetorheological Finishing (MRF) empower deterministic figure correction for the most demanding aspheres but it also enables deterministic and efficient throughput for series production of aspheres. The Q-flex MRF platform is designed to support batch production in a simple and user friendly manner. Thorlabs routinely utilizes the advancements of this platform and has provided results from using MRF to finish a batch of aspheres as a case study. We have developed an analysis notebook to evaluate necessary specifications for implementing quality control metrics. MRF brings confidence to optical manufacturing by ensuring high throughput for batch processing of aspheres.

  8. Development, Validation, and Deployment of a Revised Air Traffic Control Color Vision Test: Incorporating Advanced Technologies and Oceanic Procedures and En Route Automation Modernization Systems

    Science.gov (United States)

    2013-09-01

    through direct sampling of form and content of critical display data. Evidence of construct validity is provided by correlation with the Colour ...measured by the Colour Assessment and Diagnosis (CAD; ARTS Background Colors STARS Background Colors ERAM Background Colors Figure 3...Gelade, G. (1980). A feature-integration theory of attention. Cognitive Psychology , 12, 97–136. Xing, J. & Schroeder, D.J. (2006). Reexamination of

  9. Enzyme technology for precision functional food ingredient processes

    DEFF Research Database (Denmark)

    Meyer, Anne S.

    2010-01-01

    modification of potato starch processing residues. Such targeted enzyme-catalyzed reactions provide new invention opportunities for designing functional foods with significant health benefits. The provision of well-defined naturally structured compounds can, moreover, assist in obtaining the much...

  10. Adoption of precision agriculture technology in the Southeastern United States

    Science.gov (United States)

    Agricultural production in the Southeast is diverse and differs from other regions of the United States (U.S.). Crops grown in the Southeast are specific to the region, such as cotton and peanuts. Corn farmers supply most of the grain produced to the poultry industry to support over 15 billion dolla...

  11. Technology on precision measurement of torque and force

    International Nuclear Information System (INIS)

    2005-12-01

    This book gives a descriptions on force standards system about movement of object, direction and structure. Next, it deals with torque standards, torque measuring instrument and torque wrench with how to use, explanations, unit and test. This book written by Korea Association of standards and testing organizations is for exact measurement and test of force and torque.

  12. Precision Positioning and Inertial Guidance Sensors. Technology and Operational Aspects

    Science.gov (United States)

    1981-03-01

    At (16) VE = VE + ABY At - 2 an V NsnLt - k(VE VDE ) At (17) where VNVE = north and east velocities A Bx ABy= x- and y-acceljrometel bias in body frame...valeur nominsir., et les erreurs approprides. 7-7 L’environnement terrestre doit Otre 6galement mod~lis6. La forme terrestre eat repr~sentde par une...repbre des coordoi~r’ds terrestres . - soit en relatif par rapport h un terminal d~sign6 comme i~fdrence locale printcipake Dans cp cas la grille de

  13. Enzyme technology for precision functional food ingredient processes.

    Science.gov (United States)

    Meyer, Anne S

    2010-03-01

    A number of naturally occurring dietary substances may exert physiological benefits. The production of enhanced levels or particularly tailored versions of such candidate functional compounds can be targeted by enzymatic catalysis. The recent literature contains examples of enhancing bioavailability of iron via enzyme-catalyzed degradation of phytate in wheat bran, increasing diacyl-glycerol and conjugated linoleic acid levels by lipase action, enhancing the absorption of the citrus flavonoid hesperetin via rhamnosidase treatment, and obtaining solubilized dietary fiber via enzymatic modification of potato starch processing residues. Such targeted enzyme-catalyzed reactions provide new invention opportunities for designing functional foods with significant health benefits. The provision of well-defined naturally structured compounds can, moreover, assist in obtaining the much-needed improved understanding of the physiological benefits of complex natural substances.

  14. Rethinking the Market - Technology Relationship for Innovation

    DEFF Research Database (Denmark)

    Howells, John

    This paper revisits the 'what causes innovation - market pull or technology push?' debate to argue that the conceptualisation is flawed and that the firm is the only 'agent' capable of innovative action. The paper differentiates between 'use', 'need' and 'intended use' to obtain greater precision...... with respect to the technology-market matching process that is fundamental to innovation. The validity of the approach is demonstrated through empirical examples. These examples also show the value of distinguishing between two types of market concept used by the innovating firm. These are the 'reference...... market' which is a traded product that is a principal source of 'use' ideas for the mental construction of the 'innovation market' concept. It is the latter that can be thought to guide the construction of innovative production technology....

  15. Surface ice flow velocity and tide retrieval of the amery ice shelf using precise point positioning

    DEFF Research Database (Denmark)

    Zhang, X.H.; Andersen, Ole Baltazar

    2006-01-01

    Five days of continuous GPS observation data were collected in the frontal zone of the Amery ice shelf and subsequently post-processed using precise point position (PPP) technology based on precise orbit and clock products from the International GNSS service. The surface ice flow velocity of the ...

  16. G-DOC Plus - an integrative bioinformatics platform for precision medicine.

    Science.gov (United States)

    Bhuvaneshwar, Krithika; Belouali, Anas; Singh, Varun; Johnson, Robert M; Song, Lei; Alaoui, Adil; Harris, Michael A; Clarke, Robert; Weiner, Louis M; Gusev, Yuriy; Madhavan, Subha

    2016-04-30

    G-DOC Plus is a data integration and bioinformatics platform that uses cloud computing and other advanced computational tools to handle a variety of biomedical BIG DATA including gene expression arrays, NGS and medical images so that they can be analyzed in the full context of other omics and clinical information. G-DOC Plus currently holds data from over 10,000 patients selected from private and public resources including Gene Expression Omnibus (GEO), The Cancer Genome Atlas (TCGA) and the recently added datasets from REpository for Molecular BRAin Neoplasia DaTa (REMBRANDT), caArray studies of lung and colon cancer, ImmPort and the 1000 genomes data sets. The system allows researchers to explore clinical-omic data one sample at a time, as a cohort of samples; or at the level of population, providing the user with a comprehensive view of the data. G-DOC Plus tools have been leveraged in cancer and non-cancer studies for hypothesis generation and validation; biomarker discovery and multi-omics analysis, to explore somatic mutations and cancer MRI images; as well as for training and graduate education in bioinformatics, data and computational sciences. Several of these use cases are described in this paper to demonstrate its multifaceted usability. G-DOC Plus can be used to support a variety of user groups in multiple domains to enable hypothesis generation for precision medicine research. The long-term vision of G-DOC Plus is to extend this translational bioinformatics platform to stay current with emerging omics technologies and analysis methods to continue supporting novel hypothesis generation, analysis and validation for integrative biomedical research. By integrating several aspects of the disease and exposing various data elements, such as outpatient lab workup, pathology, radiology, current treatments, molecular signatures and expected outcomes over a web interface, G-DOC Plus will continue to strengthen precision medicine research. G-DOC Plus is available

  17. Single Crystal Piezomotor for Large Stroke, High Precision and Cryogenic Actuations, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes a novel single crystal piezomotor for large stroke, high precision, and cryogenic actuations with capability of position set-hold with...

  18. Cryogenic Stepping Piezomotor for Large Torque, Precise Rotary Motion Control in Passive Optics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes novel single crystal piezomotors for large torque, high precision, and cryogenic actuation with capability of position set-hold with...

  19. 29TH Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting

    National Research Council Canada - National Science Library

    1998-01-01

    ...) Applications of PTTI technology to evolving military navigation and communication systems; geodesy; aviation; and pulsars; 4) Dissemination of precise time and frequency by means of GPS, geosynchronous communication satellites, and computer networks.

  20. Fiscal 1998 survey report. Medical equipment (Development of fine sampling/analysis system for blood / Development of high-precision 3-D image diagnosis system / Development of low-invasion operation support system / Total development of artificial internal organ technologies); 1998 nendo chosa hokokusho. Iryo kiki (ketsuekinado biryo saishu, biryo bunseki system kaihatsu/koseido sanjigen eizo shindan system kaihatsu/teishinshu shujutsu shien system kaihatsu/jinko zoki gijutsu sogo kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    For efficient medical care supply systems, the R and D of advanced medical care technology and equipment largely contribute to productivity improvement for medical care services. Among them, a progress of medical care technology is becoming important for preparation of efficient and fair supply systems. MITI thus established 'Medical care and welfare equipment development project' in 1994, and has promoted the strategic long-term R and D project of medical care and welfare equipment as joint R and D project of NEDO and private enterprises. In fiscal 1998, on the development of the fine sampling/analysis system for blood, the high- precision 3-D image diagnosis system, the low-invasion operation support system, and the artificial internal organ technologies since fiscal 1996, this project clarified essential technical issues based on the future view, selected some themes to be newly developed in the future, and surveyed and evaluated the details of their R and D concretely. (NEDO)