WorldWideScience

Sample records for vakuum pumpe aus

  1. Efficiency of heat pump plants. Results of field tests; Effizienz von Waermepumpenanlagen. Ergebnisse aus Felduntersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Miara, Marek; Guenther, Danny [Fraunhofer-Institut fuer Solare Energiesysteme ISE (Germany)

    2011-07-01

    In Germany, households account for about 30 percent of the total end use energy consumption. In fact, if heating and water heating are taken into account, the total amounts to more than 80 percent. This shows the necessity of making heating more energy-efficient and ecological. Heat pumps are an interesting solution. The contribution investigates their efficiency in real conditions, both in new and older buildings, and also goes into the possibility of optimization during installation, control and operation. The contribution is based on the long-term heat pump monitoring projects of Fraunhofer Institut fuer Solare Energiesysteme ISE of Freiburg. [German] In den deutschen Haushalten werden rund 30 % der Endenergie verbraucht. Obwohl der Bedarf fuer die Heizung oftmals unterschaetzt wird, entfallen in den Haushalten auf die Bereiche Raumwaerme und Warmwasser tatsaechlich mehr als 80 % des Energieverbrauches. Angesichts des fortschreitenden Klimawandels sowie der Ressourcenknappheit ist es dringend notwendig, die notwendige Heizenergie moeglichst effizient und oekologisch bereitzustellen. Die Waermepumpentechnologie ist in der Lage diesen Anforderungen gerecht zu werden. Wie effizient allerdings sind die Waermepumpenanlagen unter realen Bedingungen sowohl bei Neubauten als auch bei Bestandsgebaeuden? Oder: welche Optimierungsmoeglichkeiten bestehen bei Installation, Regelung sowie Betrieb von Waermepumpenanlagen? Um diese Fragen beantworten zu koennen, fuehrt das Fraunhofer Institut fuer Solare Energiesysteme ISE aus Freiburg seit mehreren Jahren umfangreiche Monitoringprojekte durch in denen Waermepumpenanlagen im Mittelpunkt der Untersuchung stehen.

  2. Electrically driven heat pumps. Latest results from research and field tests; Elektrisch angetriebene Waermepumpen. Aktuelle Ergebnisse aus Forschung und Feldtests

    Energy Technology Data Exchange (ETDEWEB)

    Braungardt, Simon; Guenther, Danny; Miara, Marek; Wapler, Jeannette [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany); Wessing, Werner [E.ON Ruhrgas AG, Essen (Germany)

    2013-11-01

    Electric heat pumps have become firmly established in the German heating market. In recent years they have gained an eight to ten per cent share of the market. Approximately every fourth new building is heated with a heat pump. Whereas until a few years ago ground source heat pumps were still sold the most, the sales figures have shifted in recent years in favour of air source heat pumps. Carefully planned, heat pump systems compare very economically with other heating systems, whereby their higher procurement costs are offset by their lower energy and operating costs. Heat pumps are also competitive in terms of their ecological balance. This situation is continually improving with the growing proportion of renewable energies used for supplying electricity. [German] Auf dem deutschen Heizungsmarkt haben sich elektrische Waermepumpen als feste Groesse etabliert. Ihr Marktanteil lag in den letzten Jahren zwischen acht und zehn Prozent. Etwa jeder vierte Neubau wird mit einer Waermepumpe beheizt. Waehrend vor einigen Jahren noch ueberwiegend Erdreich-Waermepumpen verkauft wurden, haben sich die Verkaufszahlen in den letzten Jahren zugunsten der Aussenluft-Waermepumpen verschoben. Sorgfaeltig geplant, koennen Waermepumpenanlagen oekonomisch sehr gut gegenueber anderen Heizsystemen bestehen. Den hoeheren Anschaffungskosten stehen niedrigere Energie- und Betriebskosten gegenueber. Auch in der oekologischen Bilanz sind Waermepumpen konkurrenzfaehig. Die Position verbessert sich stetig mit dem wachsenden Anteil erneuerbarer Energien bei der Stromversorgung.

  3. News from heat-pump research - Large-scale heat pumps, components, heat pumps and solar heating; News aus der Waermepumpen-Forschung - Gross-Waermepumpen, Komponenten, Waermepumpe und Solar

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-06-15

    These proceedings summarise the presentations made at the 16{sup th} annual meeting held by the Swiss Federal Office of Energy's Heat Pump Research Program in Burgdorf, Switzerland. The proceedings include contributions on large-scale heat pumps, components and the activities of the heat pump promotion society. A summary of targets and trends in energy research in general is presented and an overview of the heat pump market in 2009 and future perspectives is given. International work within the framework of the International Energy Agency's heat pump group is reviewed, including solar - heat pump combinations. Field-monitoring and the analysis of large-scale heat pumps are discussed and the importance of the use of correct concepts in such installations is stressed. Large-scale heat pumps with carbon dioxide as working fluid are looked at, as are output-regulated air/water heat pumps. Efficient system solutions with heat pumps used both to heat and to cool are discussed. Deep geothermal probes and the potential offered by geothermal probes using carbon dioxide as a working fluid are discussed. The proceedings are rounded off with a list of useful addresses.

  4. Careful planning and execution are decisive. Efficiency of heat pump. Results from field tests; Sorgfaeltige Planung und Durchfuehrung sind entscheidend. Waermepumpenanlagen-Effizienz. Ergebnisse aus Felduntersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Miara, Marek; Guenther, Danny [Fraunhofer-Institut fuer Solare Energiesysteme ISE, Freiburg (Germany)

    2012-02-15

    In German households, nearly 30 % of the totally produced final energy is consumed. In a lot of cases, the need for heating is underestimated. In fact, 80 % of the total energy consumption of a building accounted for the areas space heating and hot water. Due to the ongoing climate change and the scarcity of resources an efficient and environmental provision of the necessary environmental heating is required. The heat pump technology will meet these requirements.

  5. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  6. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  7. Karakterizacija vakuum plazma naprskane kobalt-nikal-hrom-aluminijum-itrijum prevlake

    Directory of Open Access Journals (Sweden)

    Mihailo R. Mrdak

    2013-12-01

    Ąto su CoAl2O3 i NiAl2O3 ili (Ni,Co(Al,Cr2O4 (Tang, et al., 2004, pp.228-233. Prevlake CoNiCrAlY u deponovanom stanju imaju visoku čvrstoću spoja od 55 - 62MPa (Material Product Data Sheet, 2011, DSMTS–0092.1, Sulzer Metco i mikrotvrdoću 558 ± 43 HV0.3 za prosečnu vrednost poroznosti od 4.2%. Pored dobrih mehaničkih karakteristika, prevlake imaju nizak koeficijent trenja od 0.85 - 0,9 i otporne su na habanje (Gudmundsson, Jacobson, 1988, pp.207-217. Po preporuci proizvođača praha radna temperatura prevlaka CoNiCrAlY je ≀ 1050°C (Material Product Data Sheet, 2011, DSMTS–0092.1, Sulzer Metco. U radu su predstavljeni rezultati eksperimentalnih istraĆŸivanja uticaja sprej odstojanja na niskom pritisku na mehanička svojstva i mikrostrukturu slojeva Co32Ni21Cr8Al0.5Y prevlake. Urađene su tri grupe uzoraka sa tri različita odstojanja plazma piĆĄtolja 270, 295 i 320mm. Prevlaka sa najboljim karakteristikama je testirana na oksidaciju u peći za termičku obradu bez zaĆĄtitne atmosfere na 1100°C u trajanju od 240 sati. Glavni cilj rada je bio da se homologuju slojevi Co32Ni21Cr8Al0.5Y prevlake i primene na vazduhoplovnim delovima izloĆŸenim kombinaciji visoko temperaturne oksidacije i vrele korozije. Analizirane su mikrostrukture i mehaničke karakteristike slojeva prevlaka na osnovu čega se odabrala prevlaka najboljeg kvaliteta i homologovali vakuum plazma sprej parametri. Materijali za ispitivanje i uzorci Za eksperiment se koristio prah firme Sulcer Metko (Sulzer Metco sa oznakom AMDRY 9951. Prah Co32Ni21Cr8Al0.5Y je razvijen za izradu prevlaka koje se koriste za zaĆĄtitu metalne osnove od visoko temperaturna oksidacije i vrele korozije na temperaturama t ≀ 1050°C (Material Product Data Sheet, 2011, DSMTS–0092.1, Sulzer Metco. Metalni prah proizveden je atomizacijom tečnog rastopa legure Co32Ni21Cr8Al0.5Y inertnim gasnom argonom. Raspon granulacije čestica praha koji se koristio u eksperimentu bio je od   5 - 37ÎŒm. Osnove na koje su deponovane

  8. An always reliable energy source. 100 years unexploited: Heat from wastewater in the pump station Mannheim Ochsenpferch; Eine stets zuverlaessige Energiequelle. 100 Jahre ungenutzt. Waerme aus Abwasser im Pumpwerk Mannheim-Ochsenpferch

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Klaus W.

    2012-12-15

    Energy price increases, financial supports as well as exacerbated regulation on energy conservation increasingly makes the heat from waste water attractive and ensures a rapidly increasing number of projects. The pump station Ochsenpferch is the first reference object in Mannheim (Federal Republic of Germany). This pump station is a public station according to a standard being established in 2019 presumably.

  9. The idea from the coldness - Field test confirms high utilisation grades. New gas heat pump system; Die Idee, die aus der Kaelte kam - Feldtest bestaetigt hohe Nutzungsgrade. Neues Gaswaermepumpen-System

    Energy Technology Data Exchange (ETDEWEB)

    Heckmann, W. [Ruhrgas AG, Essen (Germany)

    2002-07-01

    The new gas-fired diffusion absorption heat pump (DAHP) developed by Buderus Heiztechnik GmbH was field-tested in the Netherlands and in Germany. Testing in Germany involved a total of 15 regional gas suppliers and was coordinated by Ruhrgas. 24 DAHP systems were installed in (existing and newly built) single-family homes. The tests showed that the efficiency of heat pumps designed for permanent operation is 25 percentage points above that of gas-fired condensing boilers. Despite some differences in the price/performance ratio, all types of heat source proved suitable. The experience gained in these tests for DAHP system installation, heating, hot water production and system temperature control will be a major contribution to help optimise DAHP systems. (orig.)

  10. Kuldma, Aus, Roosma ja Siska

    Index Scriptorium Estoniae

    2007-01-01

    2006. aasta KuldnÔela vÔitja kuulutatakse vÀlja Tallinnas Viru keskuses 9.03.2007. Kandidaadid Katrin Kuldma kollektsiooniga Chocolate, Reet Aus kaubamÀrgiga Re Use, Tiiu Roosma pesukollektsiooniga BonBon Lingerie ja Marika Siska kaubamÀrgiga Sangar

  11. Using heat from sewers for heating and cooling the IWC watch factory using a heat pump; Waermenutzung aus der Kanalisation zur Beheizung und Kuehlung der Uhrenfabrik IWC mittels Waermepumpe

    Energy Technology Data Exchange (ETDEWEB)

    Gruendler, A.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that demonstrated the feasibility of using a heat pump to provide heating energy in winter and cooling in summer using wastewater as a source of and sink for energy. The system used, including a standard refrigeration machine and a 60-metre long, 75 cm wide heat-exchanger in stainless steel is described. The main results of the project are presented in tabular form and commented on. Further work proposed is discussed, including the installation of a second machine and additional storage tanks. Costs for investments and maintenance are listed. An appendix provides photos and schematics of the equipment and installations.

  12. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  13. Niedermolekulare Verbindungen aus Spinnen als chemische Sensoren

    DEFF Research Database (Denmark)

    Olsen, Christian Adam; Kristensen, Anders S.; StrĂžmgaard, Kristian

    2011-01-01

    sie als Leitstrukturen fĂŒr die Entwicklung, Synthese und biologische Untersuchung synthetischer Analoga verwendet. Weit weniger erforscht sind hingegen Verbindungen, die der Kommunikation von Spinnen dienen. Vor kurzem wurden jedoch auf dem Gebiet der Pheromone und Allomone aus Spinnen neue...

  14. Ephemeriden aus Java, gesammelt von Edw. Jacobson

    NARCIS (Netherlands)

    Ulmer, Georg

    1913-01-01

    Aus Java waren bisher 8 Arten bekannt, nÀmlich Palingenia javanica Etn., Palingenia tenera Etn., Rhoënanthus speciosus Etn., Thalerosphyrus determinatus Walk. (alle durch Eaton, Rev. Monogr. Ephemeridae, genannt), Compsoneuria spectabilis Etn., Caenis nigropunctata Klap., Pseudocloëon Kraepelini

  15. Plecoptera aus Java. Eine neue Nemura-Art

    NARCIS (Netherlands)

    KlapĂĄlek, Fr.

    1912-01-01

    Seit der Veröffentlichung der Abhandlung: „Ueber die Neoperla-Arten aus Java” (Notes from the Leyden Museum, Vol. XXXII, p. 33) habe ich von Herrn EDW. JACOBSON weiteres Plecopteren-Material erhalten, welches sich aus folgenden Arten zusammensetzte: 1 ♂ Neoperla luteola BURM. aus Semarang (Febr.

  16. Mollusken aus posttertiÀren Schichten von Celebes

    NARCIS (Netherlands)

    Schepman, M.M.

    1912-01-01

    Die im Folgenden behandelten Mollusken stammen aus der NĂ€he von Kajoe ragi auf Celebes, woselbst sie durch R. FENNEMA aus denselben Schichten ausgelesen wurden, aus denen frĂŒher durch J. G. DE MAN einige brachyure Krebse beschrieben sind. Es darf deswegen betreffs nĂ€herer Angaben ĂŒber die Herkunft

  17. Impregnation of Graphite with Liquid Silicon in a Vacuum; Impregnation du graphite avec du silicium llquide sous vide; Propitka grafita kremniem v vakuume; Impregnacion de grafito con silicio liquido en el vacio

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, V. E.; Zelenskij, V. F.; Kolendovskij, M. K.; Kolomiets, L. D.

    1963-11-15

    A study was made of the possibility of producing high thermal resistance graphite-silicon carbide materials by means of impregnating MG graphite with liquid silicon in a vacuum. An attempt is made to explain the mechanism and origins of the degradation of products during the impregnation process. On the basis of their researches the authors put forward a number of technical requirements, observance of which make it possible to produce graphite-silicon carbide materials by means of impregnation of graphite with liquid silicon-in a vacuum at temperatures of 1450 to 1600 deg. C. (author) [French] Les auteurs etudient la possibilite d'obtenir, en impregnant du graphite MG avec du silicium liquide sous vide, des materiaux au graphite, carbure et silicium resistants a la chaleur. Ils cherchent a expliquer le mecanisme et les causes de la destruction des produits au cours de l'impregnation. Se fondant sur les resultats de leurs recherches, ils enoncent un certain nombre de conditions technologiques a remplir pour obtenir les materiaux en question en impregnant le graphite de silicium liquide sous vide, a une temperature de l'ordre de 1450 a 1600 deg. C. (author) [Spanish] Los autores han estudiado la posibilidad de preparar materiales de grafito y carburo de silicio de elevada resistencia termica impregnando grafito marca MG con silicio liquido en el vacio. Proponen una explicacion del mecanismo y de las causas de la degradacion de los productos durante la impregnacion. Sobre la base de las investigaciones realizadas, los autores enumeran una serie de condiciones tecnologicas cuyo cumplimiento permite preparar piezas de grafito y carburo de silicio, impregnando el grafito con silicio liquido en el vacio a temperaturas comprendidas entre 1450 y 1600 deg. C. [Russian] V rabote izuchalas' vozmozhnost' sozdaniya grafit-karbidkremnievykh materialov s povyshennoj termostojkost'yu putem propitki grafita marki MG zhidkim kremniem v vakuume. Sdelana popytka ob{sup y

  18. Estudo das ausĂȘncias da equipe de enfermagem

    Directory of Open Access Journals (Sweden)

    Janaina HaidĂȘ Rodrigues Belem

    1998-12-01

    Full Text Available As ausĂȘncias dos elementos da equipe de enfermagem comprometem a organização do trabalho causando sobrecarga dessa equipe, e queda na qualidade da assistĂȘncia de enfermagem. O presente estudo caracteriza o tipo e distribuição das ausĂȘncias da equipe de enfermagem em um hospital geral de grande porte, propondo um Ă­ndice de Segurança TĂ©cnica para cobertura das ausĂȘncias a partir da realidade investigada. Foram estudadas 8 tipos de ausĂȘncias entre previstas e nĂŁo previstas. O maior nĂșmero de tipos de ausĂȘncias encontradas foram aquelas referentes Ă  ausĂȘncias previstas, em seqĂŒĂȘncia encontramos licença maternidade representando o maior nĂșmero de ausĂȘncias nĂŁo previstas.

  19. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  20. Reet Aus - egoismiĂŒlikooli Ă”ppejĂ”ud / Reet Aus ; intervjueerinud Tanel Veenre

    Index Scriptorium Estoniae

    Aus, Reet, 1974-

    2009-01-01

    Moekunstnik Reet Aus osalemisest oma kollektsiooniga Londoni moenÀdala raames toimunud nÀitusel "Estethica", rohelisest disainist, tööst teatrikunstnikuna, oma kaubamÀrgist ReUse, moekunsti eelistest ja puudustest, ilust, endast, majanduskriisist, linnastumisest

  1. AUS98 - The 1998 version of the AUS modular neutronic code system

    International Nuclear Information System (INIS)

    Robinson, G.S.; Harrington, B.V.

    1998-07-01

    AUS is a neutronics code system which may be used for calculations of a wide range of fission reactors, fusion blankets and other neutron applications. The present version, AUS98, has a nuclear cross section library based on ENDF/B-VI and includes modules which provide for reactor lattice calculations, one-dimensional transport calculations, multi-dimensional diffusion calculations, cell and whole reactor burnup calculations, and flexible editing of results. Calculations of multi-region resonance shielding, coupled neutron and photon transport, energy deposition, fission product inventory and neutron diffusion are combined within the one code system. The major changes from the previous AUS publications are the inclusion of a cross-section library based on ENDF/B-VI, the addition of the MICBURN module for controlling whole reactor burnup calculations, and changes to the system as a consequence of moving from IBM main-frame computers to UNIX workstations This report gives details of all system aspects of AUS and all modules except the POW3D multi-dimensional diffusion module

  2. AUS98 - The 1998 version of the AUS modular neutronic code system

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, G.S.; Harrington, B.V

    1998-07-01

    AUS is a neutronics code system which may be used for calculations of a wide range of fission reactors, fusion blankets and other neutron applications. The present version, AUS98, has a nuclear cross section library based on ENDF/B-VI and includes modules which provide for reactor lattice calculations, one-dimensional transport calculations, multi-dimensional diffusion calculations, cell and whole reactor burnup calculations, and flexible editing of results. Calculations of multi-region resonance shielding, coupled neutron and photon transport, energy deposition, fission product inventory and neutron diffusion are combined within the one code system. The major changes from the previous AUS publications are the inclusion of a cross-section library based on ENDF/B-VI, the addition of the MICBURN module for controlling whole reactor burnup calculations, and changes to the system as a consequence of moving from IBM main-frame computers to UNIX workstations This report gives details of all system aspects of AUS and all modules except the POW3D multi-dimensional diffusion module refs., tabs.

  3. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  4. AUS burnup module CHAR and the associated data pool

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1975-12-01

    The CHAR module of the AUS reactor neutronics scheme solves the multiregion nuclide depletion equations using an analytic method. The module obtains cross section, flux and geometry data from AUS data pools, and uses the STATUS data pool which has been designed for the storage of nuclide compositions, spatial smearing factors and other miscellaneous information. (author)

  5. Risiko Energiewende Wege aus der Sackgasse

    CERN Document Server

    Kleinknecht, Konrad

    2015-01-01

    Der Ausstieg aus der Nutzung der Kernenergie in Deutschland wurde im Sommer 2011 im Eiltempo beschlossen. Jetzt zeigt sich, dass es keinen realistischen Plan fĂŒr den Umbau der Energieversorgung in der vorgesehenen Frist von zehn Jahren gibt. FĂŒr die Umstellung unserer gesamten Stromversorgung und damit unserer Wirtschaft ist der Zeitraum zu kurz. Es fehlt eine belastbare empirische BegrĂŒndung, die Fragen der Versorgungssicherheit, der Finanzierbarkeit, der Auswirkungen auf die wirtschaftliche Entwicklung und die soziale Gerechtigkeit behandeln mĂŒsste. Somit droht diese Wende an ihren WidersprĂŒchen zu scheitern. Konrad Kleinknecht versucht in seinem Buch, die Probleme zu benennen und Antworten zu finden. FĂŒr ihn stellen sich die folgenden Fragen: Welche Möglichkeit haben wir, mit Windkraft und Solarenergie einen Teil der Stromversorgung zu ersetzen? Welche Stromquellen bieten gesicherte Leistung? Können wir auf Kohlekraftwerke verzichten? Brauchen wir neue Stromtrassen? Wie lĂ€sst sich Strom speichern?...

  6. Zusammenarbeit aus Sicht eines outgesourcten Instandhalters

    Science.gov (United States)

    GrĂŒĂŸer, Stefan; Loeven, Heinz-Wilhelm

    Dauerhafter Unternehmenserfolg ist nur mit einer fortschrittlichen Instandhaltung zu erzielen. Durch den enormen Kostendruck infolge der Globalisierung und die InnovationssprĂŒnge auf der technischen Seite wird auch die Frage nach der modernen Organisationsform fĂŒr die Instandhaltung gestellt. Eine Möglichkeit der Kostenoptimierung ist das Outsourcing von Instandhaltungsleistungen. Hierbei ist es unerlĂ€sslich, dass sich die Mitarbeiter zum Dienstleister entwickeln. In diesem Beitrag wird die Entwicklung der InfraServ Knapsack von einer internen Instandhaltungsabteilung hin zu einem Industriellen Dienstleister beschrieben und Aspekte der Zusammenarbeit mit externen Kunden aus der Sicht des outgesourcten Instandhalters geschildert. Es werden die wichtigen Entwicklungsschritte zur Dienstleistungsorientierung der frĂŒheren Eigeninstandhaltung aufgezeigt. Dieser Beitrag ist nicht als "Königsweg“ zu verstehen, er soll vielmehr anhand der Erfahrungen einer outgesourcten Eigeninstandhaltung Anregungen fĂŒr die Entwicklung der eigenen Instandhaltungsorganisation liefern.

  7. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  8. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  9. Zusammensetzung eukaryotischer RNase P aus pflanzlichen Zellkernen und Plastiden

    OpenAIRE

    Heubeck, Christian

    2004-01-01

    Ribonuklease P (RNaseP) ist eine essentielle Endonuklease, welche die 5'-Flanke von pre-tRNAs entfernt. In nahezu allen bisher untersuchten Organismen und Organellen besteht das Holoenzym aus einer RNA-Untereinheit und einer Protein-Komponente. Nur die Zusammensetzung des Enzyms in den Chloroplasten und Mitochochondrien mehrzelliger Eukaryonten scheint unklar. Eine RNA-Untereinheit konnte hier bis jetzt nicht nachgewiesen werden. Um den Aufbau der RNaseP aus photosynthetischen...

  10. Neues aus dem Forschungsfeld Deutsch als Zweitsprache. Sammelrezension

    Directory of Open Access Journals (Sweden)

    Claus Altmayer

    2015-03-01

    Full Text Available Neues aus dem Forschungsfeld Deutsch als Zweitsprache. Sammelrezension (Teil 2 von Bernt Ahrenholz (Hrsg. (2009, Empirische Befunde zu DaZ-Erwerb und Sprachförderung. BeitrĂ€ge aus dem 3. ‚Workshop Kinder mit Migrationshintergrund‘; Karen Schramm & Christoph Schröder (Hrsg. (2009, Empirische ZugĂ€nge zu Spracherwerb und Sprachförderung in Deutsch als Zweitsprache; Stefan Jeuk (2010, Deutsch als Zweitsprache in der Schule. Grundlagen - Diagnose – Förderung

  11. Centrifugal pumps

    CERN Document Server

    GĂŒlich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  12. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  13. ESWL aus der Sicht des Osteologen

    Directory of Open Access Journals (Sweden)

    Tischer T

    2004-01-01

    Full Text Available In der Urologie hat die ZertrĂŒmmerung von schmerzhaften Nierensteinen mittels extrakorporaler Stoßwellen die nicht-invasive Therapie von Nierensteinen revolutioniert. Dieses erfolgversprechende Konzept wurde vor ĂŒber 15 Jahren in der OrthopĂ€die aufgegriffen. Dabei wurde versucht, die verzögerte Knochenbruchheilung durch Stimulation der Knochenenden mit Hilfe fokussierter extrakorporaler Stoßwellen zu beschleunigen. Im folgenden wurde dieses Verfahren erfolgreich zur Behandlung von Knochenbruchheilungsstörungen, der Tendinitis calcarea, der Epicondylitis radialis humeri und der Fasciitis plantaris eingesetzt. Dabei ist – anders als bei der NierensteinzertrĂŒmmerung – nicht die Zerstörung von Hartgewebe fĂŒr den Wirkmechanismus verantwortlich. Lange Zeit waren die Kenntnisse sowohl ĂŒber die Wirkmechanismen extrakorporaler Stoßwellen am Knochen, als auch ĂŒber mögliche unerwĂŒnschte Nebenwirkungen nur eingeschrĂ€nkt verfĂŒgbar. In den letzten Jahren sind jedoch viele neue Studien publiziert worden. Die vorliegende Arbeit faßt den entsprechenden gegenwĂ€rtigen Kenntnisstand ĂŒber die Wirkung extrakorporaler Stoßwellen auf den Knochen aus tier- und zellkulturexperimentellen Grundlagenuntersuchungen zusammen. Insbesondere in bezug auf mögliche unerwĂŒnschte Nebenwirkungen der ESWT haben die bisher durchgefĂŒhrten Untersuchungen wertvolle Hinweise ergeben. DarĂŒber hinaus konnten in jĂŒngster Zeit erste Ergebnisse bezĂŒglich der molekularen Wirkweise extrakorporaler Stoßwellen am StĂŒtz- und Bewegungsapparat vorgelegt werden, die ein komplexes Bild der tatsĂ€chlichen VorgĂ€nge erahnen lassen. Durch eine Intensivierung der tierexperimentellen Grundlagenforschung zur ESWT wird es möglich sein, in naher Zukunft eine breit abgesicherte, experimentell-wissenschaftliche Grundlage zum Einsatz extrakorporaler Stoßwellen am StĂŒtz- und Bewegungsapparat zu erarbeiten.

  14. A guide to the AUS modular neutronics code system

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1987-04-01

    A general description is given of the AUS modular neutronics code system, which may be used for calculations of a very wide range of fission reactors, fusion blankets and other neutron applications. The present system has cross-section libraries derived from ENDF/B-IV and includes modules which provide for lattice calculations, one-dimensional transport calculations, and one, two, and three-dimensional diffusion calculations, burnup calculations and the flexible editing of results. Details of all system aspects of AUS are provided but the major individual modules are only outlined. Sufficient information is given to enable other modules to be added to the system

  15. AUS - the Australian modular scheme for reactor neutronics computations

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1975-12-01

    A general description is given of the AUS modular scheme for reactor neutronics calculations. The scheme currently includes modules which provide the capacity for lattice calculations, 1D transport calculations, 1 and 2D diffusion calculations (with feedback-free kinetics), and burnup calculations. Details are provided of all system aspects of AUS, but individual modules are only outlined. A complete specification is given of that part of user input which controls the calculation sequence. The report also provides sufficient details of the supervisor program and of the interface data sets to enable additional modules to be incorporated in the scheme. (author)

  16. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  17. Electromagnetic pump

    International Nuclear Information System (INIS)

    Ito, Koji; Suetake, Norio; Aizawa, Toshie; Nakasaki, Masayoshi

    1998-01-01

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  18. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  19. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  20. Eine neue Tornaria aus dem Ostindischen Archipel (Tornaria Sunieri)

    NARCIS (Netherlands)

    Stiasny, G.

    1921-01-01

    Da aus dem malayischen Archipel durch die Siboga-Monographie Spengels (2) zwar eine Anzahl Enteropneusten, jedoch nur eine einzige Tornaria bekannt worden ist, war anzunehmen, dass noch andere Tornarien in diesem Gebiete nachzuweisen sein wĂŒrden. Von dieser Erwartung ausgehend wandte ich mich an

  1. Fluidic pumps

    International Nuclear Information System (INIS)

    Priestman, G.H.

    1990-01-01

    A fluidic pump has primary and secondary vessels connected by a pipe, a displacement vessel having liquid to be delivered through a pipe via a rectifier provided with a feed tank. A drive unit delivers pressure fluid to a line to raise liquid and compress trapped gas or liquid in the space, including the pipe between the liquids in the two vessels and thus drive liquid out of the displacement vessel. The driving gas is therefore separated by the barrier liquid and the trapped gas or liquid from the liquid to be pumped which liquid could be e.g. radioactive. (author)

  2. Pumped storage

    International Nuclear Information System (INIS)

    Strauss, P.L.

    1991-01-01

    The privately financed 1,000 MW Rocky Point Pumped Storage Project located in central Colorado, USA, will be one of the world's highest head, 2,350 feet reversible pump/turbine projects. The project will offer an economical supply of peaking power and spinning reserve power to Colorado and other southwestern states. This paper describes how the project will be made compatible with the environmental conditions in the project area and the type of terrestrial mitigation measures that are being proposed for those situations where the project impacts the environment, either temporarily or permanently

  3. The role of ABC proteins Aus1p and Pdr11p in the uptake of external sterols in yeast: dehydroergosterol fluorescence study

    DEFF Research Database (Denmark)

    Kohut, Peter; WĂŒstner, Daniel; Hronska, L

    2011-01-01

    of sterol molecules into plasma membrane is not spontaneous but requires assistance of two ABC (ATP-binding cassette) pumps--Aus1p or Pdr11p. DHE taken up by uptake-competent hem1ΔAUS1PDR11 cells could be directly visualized by UV-sensitive wide field fluorescence microscopy. HPLC analysis of sterols......Uptake of external sterols in the yeast Saccharomyces cerevisiae is a multistep process limited to anaerobiosis or heme deficiency. It includes crossing the cell wall, insertion of sterol molecules into plasma membrane and their internalization and integration into intracellular membranes. We...... applied the fluorescent ergosterol analog dehydroergosterol (DHE) to monitor the initial steps of sterol uptake by three independent approaches: fluorescence spectroscopy, fluorescence microscopy and sterol quantification by HPLC. Using specific fluorescence characteristics of DHE we showed that the entry...

  4. Sintered silicon carbides for sliding applications in pumps; Pumpenbauteile aus SSiC

    Energy Technology Data Exchange (ETDEWEB)

    Fundus, M. [Wacker Engineer Ceramics, Inc., Adrian, MI (United States)

    2000-07-01

    The focus of the paper is on enhancement and optimization of the tribological properties of SSiC materials based on field experience obtained with the materials EKasic {sup trademark} D, TRIBO 2000, and TRIBO 2000-1. Current product development activities discussed in this paper concentrate on slide bearings and seal rings. (orig./cB) [German] Mit EKasic {sup trademark} D, TRIBO 2000 und TRIBO 2000-1 stehen drei SiC-Werkstoffe zur Verfuegung, die in der Lage sind die ganze Bandbreite der Anwendungen abzudecken. Durch eine konsequente Fortsetzung der tribologischen Optimierung der SiC-Werkstoffe koennen auch die in den naechsten Jahren weiter steigenden Anforderungen im Lager- und Dichtungsbereich erfuellt werden (Gleitringdichtungen, Gleitlager). (orig./MM)

  5. 371 Exhumierungen : eine Untersuchung aus morphologischer, versicherungsmedizinischer und rechtsmedizinischer Sicht

    OpenAIRE

    Ulm, Kristin

    2008-01-01

    In der vorliegenden Arbeit wurden die Ergebnisse von 371 Exhumierungen aus den Jahren 1967 bis 1998 ausgewertet unter der Fragestellung, ob aussagekrÀftige morphologische Befunde auch noch nach einer lÀngeren Leichenliegezeit erhoben werden und versicherungsmedizinische Fragen hierdurch beantwortet werden können. Die erhobenen morphologischen Befunde sowohl auf mikroskopischer als auch auf makroskopischer Ebene wurden zu einem Erwartungskatalog zusammengefasst und mit den Ergebnissen der...

  6. RĂ€umliche Aspekte von Transformationsproblemen aus systemtheoretischer Perspektive

    OpenAIRE

    KlĂŒter, Helmut

    2000-01-01

    Der mit dem Topos "Transformation von Wirtschafts- und Gesellschaftssystemen" axiomatisch angenommene Unvereinbarkeit sozialistischer und marktwirtschaftlicher Strukturen ist aus raumwissenschaftlicher Sicht nicht nachvollziehbar. Zum einen gibt es in Wirtschaftsgeographie und Infrastrukturtheorie eine ganze Reihe von Gemeinsamkeiten und BerĂŒhrungspunkten, die man fĂŒr den konstruktiven Systemumbau nutzen kann. Zum andern benötigt der Umbau selbst eine rĂ€umliche Infrastruktur. Und zum dritten ...

  7. Solar Pump

    Science.gov (United States)

    Pique, Charles

    1987-01-01

    Proposed pump moves liquid by action of bubbles formed by heat of sun. Tube of liquid having boiling point of 100 to 200 degrees F placed at focal axis of cylindrical reflector. Concentrated sunlight boils liquid at focus, and bubbles of vapor rise in tube, carrying liquid along with them. Pressure difference in hot tube sufficient to produce flow in large loop. Used with conventional flat solar heating panel in completely solar-powered heat-storage system.

  8. Gas flow through the clearances of screw spindle vacuum pumps; Gasspaltstroemungen in Schraubenspindel-Vakuumpumpen

    Energy Technology Data Exchange (ETDEWEB)

    Kauder, K.; Wenderott, D. [Dortmund Univ. (Germany). FG Fluidenergiemaschinen

    1998-12-31

    The documentation `Schraubenmaschinen` deals with the subject `screw spindle vacuum pump` for the first time. Therefore, this paper presents the type of maschine `screw spindle vacuum pump`, fixes its limits to the better known screw type compressor and finally classifies it in the crossover of vacuum-technology, characteristic geometry and the numerical simulation. The suggested reflections to choose a proper model of flow are based on the geometry of the screw spindle vacuum pump and fundamentals concerning the vacuum-technology and the state of flow. (orig.) [Deutsch] Die Schriftenreihe `Schraubenmaschinen` behandelt erstmals das Thema `Schraubenspindel-Vakuumpumpe`. Aus diesem Grund stellt der vorliegende Beitrag den Maschinentyp Schraubenspindel-Vakuumpumpe vor, grenzt ihn zur bekannteren Schraubenmaschine ab und ordnet ihn in der Schnittmenge aus Vakuumtechnik, charakteristischer Maschinengeometrie und der Simulation ein. Auf den vakuumtechnischen und stroemungstechnischen Grundlagen sowie geometrischen Betrachtungen basieren die genannten Ueberlegungen zur Auswahl geeigneter Stroemungsmodelle. (orig.)

  9. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  10. Heating load of buildings. Room heat from decentralized renewable electricity; Heizlast von Gebaeuden. Raumwaerme aus dezentral erneuerbarem Strom

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Frank

    2013-10-15

    If one would like to get the heating load of a building by using peripheral generated electrical energy from photovoltaics or small wind power, one must deal with both the specific building, as well as the heating load, the heating temperature limit and the differentiation of specific heating period for the building. Here, a ground source heat pump with an intelligent energy storage system seems to be the first choice. [German] Moechte man mit dezentral erzeugter elektrischer Energie aus Photovoltaik oder Kleinst-Windkraft die Heizlast eines Gebaeudes besorgen, muss man sich sowohl mit dem spezifischen Gebaeude, als auch mit der Heizlast, der Heizgrenztemperatur und der Differenzierung der spezifischen Heizperiode fuer das Gebaeude auseinandersetzen. Dabei scheint eine erdgekoppelte Waermepumpe mit einem intelligenten Speichersystem die erste Wahl.

  11. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  12. Internal pump

    International Nuclear Information System (INIS)

    Kushima, Jun; Hayashi, Youjiro; Ueda, Masayuki.

    1997-01-01

    The present invention relates to an internal pump. A water hole allowing communication between internal and external circumferences of a stretch tube is provided at the portion of the stretch tube corresponding to a position where an end face of a nozzle portion of a motor case and an end face of a diffuser are joined with each other so that hot filtered water inside a pressure container which has entered from where the end face of the nozzle portion of the motor case and the end face of the diffuser are joined with each other is combined with the purged water so that it can be sent back to the pressure container again. (author) figs

  13. Energy from biomass. Teaching material; Energie aus Biomasse. Ein Lehrmaterial

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-04-01

    The textbook discusses the available options for power and heat generation from biomass as well as the limits of biomass-based power supply. The main obstacle apart from the high cost is a lack of knowledge, which the book intends to remedy. It addresses students of agriculture, forestry, environmental engineering, heating systems engineering and apprentice chimney sweepers, but it will also be useful to all other interested readers. [German] Biomasse kann aufgrund seiner vielfaeltigen Erscheinungs- und Umwandlungsformen sowohl als Brennstoff zur Waerme- und Stromgewinnung oder als Treibstoff eingesetzt werden. Die energetische Nutzung von Biomasse birgt zudem nicht zu verachtende Vorteile. Zum einen wegen des Beitrags zum Klimaschutz aufgrund der CO{sub 2}-Neutralitaet oder einfach, weil Biomasse immer wieder nachwaechst und von fossilen Ressourcen unabhaengig macht. All den bisher erschlossenen Moeglichkeiten der energetischen Nutzung von Biomasse moechte dieses Lehrbuch Rechnung tragen. Es zeigt aber auch die Grenzen auf, die mit der Energieversorgung durch Bioenergie einhergehen. Hohe Kosten und ein erhebliches Informationsdefizit behinderten bisher eine verstaerkte Nutzung dieses Energietraeges. Letzterem soll dieses Lehrbuch entgegenwirken. Das vorliegende Lehrbuch wurde fuer die Aus- und Weiterbildung erstellt. Es richtet sich vor allem an angehende Land- und Forstwirte, Umwelttechniker, Heizungsbauer und Schornsteinfeger, ist aber auch fuer all diejenigen interessant, die das Thema ''Energie aus Biomasse'' verstehen und ueberblicken moechten. (orig.)

  14. Breastfeeding FAQs: Pumping

    Science.gov (United States)

    ... of pump is best? You can buy or rent a breast pump from lactation consultants, hospitals, retail ... place to do it. Many companies offer their employees pumping and nursing areas. If yours doesn't, ...

  15. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  16. Liquid metal pump

    Science.gov (United States)

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  17. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair

  18. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  19. ANAUSN - a one-dimensional multigroup SN transport theory module for the AUS reactor neutronics system

    International Nuclear Information System (INIS)

    Clancy, B.E.

    1982-05-01

    ANAUSN is a general purpose, one-dimensional discrete ordinate transport theory program which has access to AUS datapools. Fixed source, reactivity and a variety of criticality search calculations can be performed. The program can be operated as a module in the AUS scheme or as a stand-alone program

  20. Dry vacuum pumps

    International Nuclear Information System (INIS)

    Sibuet, R

    2008-01-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R and D/industries, merits over conventional pumps and future growth scope will be discussed

  1. Das Archiv der Familie Szwojnicki aus BorkƂojnie

    Directory of Open Access Journals (Sweden)

    Andrzej Mycio

    2017-11-01

    Full Text Available 2004 erwarb die UniversitĂ€tsbibliothek in Thorn einen kleinen Bestand, das Privatarchiv der Familie Szwojnicki, die bis zum Zweiten Weltkrieg ihre LandgĂŒter in BorkƂojnie in der Republik Litauen inne hatte. Die von den nacheinander folgenden Familienvertretern gesammelten Materialien, die sich bis zum heutigen Tag bewĂ€hrten, erlauben die wichtigsten Schicksale dieser Familie wiederherzustellen. Die Szwojnickis waren eine Familie der Landesbeamten. Im 19. Jahrhundert waren ihre LandgĂŒter in BorkƂojnie ein Hort, wo die polnischen Truppen wĂ€hrend des Januaraufstandes unterstĂŒtzt, geschĂŒtzt und versorgt wurden. Die LandgĂŒter wurden von 1897 bis zum Ende des Zweiten Weltkrieges von Zygmunt Szwojnicki verwaltet. In der Zwischenkriegszeit bemĂŒhte er sich aktiv um die Bewahrung der nationalen IdentitĂ€t der in der Republik Litauen lebenden Polen. 1946 wurde er zusammen mit anderen Polen in den polnischen Staat umgesiedelt. Das ganze Familienarchiv Szwojnickis ist einer der kleineren ArchivbestĂ€nde, die in der UniversitĂ€tsbibliothek in Thorn aufbewahrt werden. Dazu gehörten insgesamt 12 Inventareinheiten. Das Ă€lteste Dokument in diesem Bestand stammt aus dem Jahr 1531, das jĂŒngste aus dem Jahr 1946. Die erhaltenen Archivalien entstanden also innerhalb von ĂŒber 400 Jahren. Sie schildern die Schicksale der Familie Szwojnicki und ihrer LandgĂŒter in BorkƂojnie. Der Archivbestand der Familie Szwojnicki ist ein typisches Beispiel von Familienakten des nicht so wohlhabenden polnischen Adels, der die Gebiete Litauens bewohnte. Es bewĂ€hrten sich vor allem die Urkunden, die von den AnsprĂŒchen der Familie auf den Adelstitel sowie auf die LandgĂŒter zeugen, darĂŒber hinaus: Matrikelakten, Testamente, Finanzurkunden sowie biografische Materialien in Bezug auf den letzten EigentĂŒmer Zygmunt Szwojnicki.

  2. Solar Pumping : The Basics

    OpenAIRE

    World Bank Group

    2018-01-01

    Solar photovoltaic water pumping (SWP) uses energy from solar photovoltaic (PV) panels to power an electric water pump. The entire process, from sunlight to stored energy, is elegant and simple. Over last seven years, the technology and price of solar pumping have evolved dramatically and hence the opportunities it presents. Solar pumping is most competitive in regions with high solar inso...

  3. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  4. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  5. The Yeast Plasma Membrane ATP Binding Cassette (ABC) Transporter Aus1

    Science.gov (United States)

    Marek, Magdalena; Milles, Sigrid; Schreiber, Gabriele; Daleke, David L.; Dittmar, Gunnar; Herrmann, Andreas; MĂŒller, Peter; Pomorski, Thomas GĂŒnther

    2011-01-01

    The ATP binding cassette (ABC) transporter Aus1 is expressed under anaerobic growth conditions at the plasma membrane of the yeast Saccharomyces cerevisiae and is required for sterol uptake. These observations suggest that Aus1 promotes the translocation of sterols across membranes, but the precise transport mechanism has yet to be identified. In this study, an extraction and purification procedure was developed to characterize the Aus1 transporter. The detergent-solubilized protein was able to bind and hydrolyze ATP. Mutagenesis of the conserved lysine to methionine in the Walker A motif abolished ATP hydrolysis. Likewise, ATP hydrolysis was inhibited by classical inhibitors of ABC transporters. Upon reconstitution into proteoliposomes, the ATPase activity of Aus1 was specifically stimulated by phosphatidylserine (PS) in a stereoselective manner. We also found that Aus1-dependent sterol uptake, but not Aus1 expression and trafficking to the plasma membrane, was affected by changes in cellular PS levels. These results suggest a direct interaction between Aus1 and PS that is critical for the activity of the transporter. PMID:21521689

  6. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump. 13 refs., 5 figs., 1 tab

  7. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 is pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump

  8. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru

  9. Continuously pumping and reactivating gas pump

    International Nuclear Information System (INIS)

    Batzer, T.H.; Call, W.R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped

  10. Continuously pumping and reactivating gas pump

    Science.gov (United States)

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  11. Zeolithhaltige Katalysatoren fĂŒr die Nachbehandlung von sauerstoffreichem Abgas aus Verbrennungsmotoren

    OpenAIRE

    Scharr, Detlef

    2007-01-01

    Im Rahmen dieser Arbeit wurden neuartige Katalysatoren fĂŒr die Minderung der Stickoxide in sauerstoffreichem Abgas aus Verbrennungsmotoren untersucht. Als Katalysatoren wurden physikalische Mischungen aus unterschiedlichen Zeolithen und Übergangsmetalloxiden verwendet. Der Zeolith soll die Kohlenwasserstoffe im Abgas zu einem geeigneten Reduktionsmittel aufbereiten, das die Stickoxide am Übergangsmetall wirksam reduziert. Da ĂŒber das Zusammenwirken der beiden Materialien in der Mischung ...

  12. Pumps in mining

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This article looks at the pump industry as a whole, its historical links with the mining industry, their parallel develop ment, and at the individual manufacturers and pumps, services and auxillary products they have to offer.

  13. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  14. Rotary magnetic heat pump

    Science.gov (United States)

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  15. Vertical pump assembly

    International Nuclear Information System (INIS)

    Dohnal, M.; Rosel, J.; Skarka, V.

    1988-01-01

    The mounting is described of the drive assembly of a vertical pump for nuclear power plants in areas with seismic risk. The assembly is attached to the building floor using flexible and damping elements. The design allows producing seismically resistant pumps without major design changes in the existing types of vertical pumps. (E.S.). 1 fig

  16. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.A.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. These can generally be classified as: Mechanical; Hydraulic; Tribological; Chemical; and Other (including those associated with the pump driver). Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump

  17. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    A liquid metal pump comprising a shaft support structure which is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft carries an impeller and the support structure carries an impeller cage which is slidably disposed in a diffuser so as to allow complete removal of pump internals for inspection and repair. The diffuser is concentrically supported in the pump housing which also takes up all reaction forces generated by the discharge of the liquid metal from the diffuser, with floating seals arranged between impeller cage and the diffuser. The space between the diffuser and the pump housing permits the incoming liquid to essentially surround the diffuser. (author)

  18. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  19. Pumps for nuclear facilities

    International Nuclear Information System (INIS)

    1999-01-01

    The guide describes how the Finnish Radiation and Nuclear Safety Authority (STUK) controls pumps and their motors at nuclear power plants and other nuclear facilities. The scope of the control is determined by the Safety Class of the pump in question. The various phases of the control are: (1) review of construction plan, (2) control of manufacturing, and construction inspection, (3) commissioning inspection, and (4) control during operation. STUK controls Safety Class 1, 2 and 3 pumps at nuclear facilities as described in this guide. STUK inspects Class EYT (non-nuclear) pumps separately or in connection with the commissioning inspections of the systems. This guide gives the control procedure and related requirements primarily for centrifugal pumps. However, it is also applied to the control of piston pumps and other pump types not mentioned in this guide

  20. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  1. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  2. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-12-31

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  3. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-01-01

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  4. DNA fingerprinting and diversity analysis in Aus genotypes using microsatellite markers

    Directory of Open Access Journals (Sweden)

    MD. MONIRUL ISLAM

    2015-08-01

    Full Text Available DNA fingerprinting and genetic diversity of 94 Aus (6 BRRI released Aus variety and 88 local Aus landraces genotypes were carried out to protect the Aus landraces from biopiracy. A total of 91 microsatellite markers were tested for screening the genotypes. Among 91 amplified products, 56% have polymorphic bands giving 195 alleles. The number of alleles per locus ranged from four (RM25 and RM147 to twenty seven (RM519, where average allele number was 9.76. The Polymorphism Information Contents (PIC lied between 0.455 (RM5 to 0.934 (RM519. Most robust marker was found RM519 since it provided the highest PIC value (0.934. Pair-wise genetic dissimilarity co-efficient showed the lowest genetic dissimilarity was found BRRI dhan42 and BRRI dhan43 and the highest genetic dissimilarity was found local landraces each other. Here it is shown that most Aus landraces is recognized to have broad genetic base. Thus it is recommended to use these landraces for future breeding program or include new and untouched local landraces to incorporate new genes and broaden genetic base.

  5. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Phillip M. Paul

    2000-01-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  6. Electrokinetic pumps and actuators

    Energy Technology Data Exchange (ETDEWEB)

    Phillip M. Paul

    2000-03-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps.

  7. Detection of pump degradation

    International Nuclear Information System (INIS)

    Greene, R.H.; Casada, D.A.; Ayers, C.W.

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  8. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  9. Thermomechanical piston pump development

    Science.gov (United States)

    Sabelman, E. E.

    1971-01-01

    A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

  10. Pumps for nuclear industry

    International Nuclear Information System (INIS)

    Tanguy, L.

    1978-01-01

    In order to meet the requirements of nuclear industry for the transfer of corrosive, toxic, humidity sensitive or very pure gases, different types of pumps were developped and commercialized. Their main characteristics are to prevent pollution of the transfered fluid by avoiding any contact between this fluid and the lubricated parts of the machine, and to prevent a contamination of the atmosphere or of the fluid by a total tightness. Patellar pumps have been particularly developped because the metallic bellows are quite reliable and resistant in this configuration. Two types are described: patellar pumps without friction and barrel pumps whose pistons are provided with rings sliding in the cylinders without lubrication [fr

  11. Pump safety device

    International Nuclear Information System (INIS)

    Timmermans, Francis; Vandervorst, Jean.

    1981-01-01

    Safety device for longitudinally leak proofing the shaft of a pump in the event of the fracture of the dynamic seal separating the pump fluid high pressure chamber from the low pressure chamber. It is designed for fitting to the primary pumps of nuclear reactors. It includes a hollow cyclindrical piston located coaxially around the pump shaft and normally housed in a chamber provided for this purpose in the fixed housing of the dynamic seal, and means for moving this piston coaxially so as to compress a safety O ring between the shaft and the piston in the event of the dynamic seal failing [fr

  12. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  13. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1995-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  14. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  15. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    Mekelle University, Mekelle, Ethiopia (*mul_at@yahoo.com). ABSTRACT. A wind ... balanced rotor power and reciprocating pump, hence did not consider the effect of pump size. ... Keywords: Wind pump, Windmill, Performance testing, Pump efficiency, Pump discharge, ... Unfortunately, in rural places, where the houses are.

  16. AUS module MIRANDA - a data preparation code based on multiregion resonance theory

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1977-07-01

    MIRANDA is a data preparation module of the AUS reactor neutronics scheme and is used to prepare multigroup cross-section data which are pertinent to a particular reactor system from a general purpose multigroup library of cross sections. The cross-section library has been prepared from ENDF/B and includes temperature dependent data and resonance cross sections represented by subgroup parameters. The MIRANDA module includes a multiregion resonance calculation in slab, cylinder or cluster geometry, a homogeneous Bsub(L) flux solution, and a group condensation facility. Interaction with other AUS modules, particularly for burnup calculations, is provided. (Author)

  17. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous spectral vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition: advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  18. Normetex Pump Alternatives Study

    International Nuclear Information System (INIS)

    Clark, Elliot A.

    2013-01-01

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying

  19. A comparison of neutron resonance absorption in thermal reactor lattices in the AUS neutronics code system with Monte Carlo calculations

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1985-08-01

    The calculation of resonance shielding by the subgroup method, as incorporated in the MIRANDA module of the AUS neutronics code system, is compared with Monte Carlo calculatons for a number of thermal reactor lattices. For the large range of single rod and rod cluster lattices considered, AUS results for resonance absorption were high by up to two per cent

  20. Circulation pump mounting

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    The suspension is described of nuclear reactor circulating pumps enabling their dilatation with a minimum reverse force consisting of spacing rods supported with one end in the anchor joints and provided with springs and screw joints engaging the circulating pump shoes. The spacing rods are equipped with side vibration dampers anchored in the shaft side wall and on the body of the circulating pump drive body. The negative reverse force F of the spacing rods is given by the relation F=Q/l.y, where Q is the weight of the circulating pump, l is the spatial distance between the shoe joints and anchor joints, and y is the deflection of the circulating pump vertical axis from the mean equilibrium position. The described suspension is advantageous in that that the reverse force for the deflection from the mean equilibrium position is minimal, dynamic behaviour is better, and construction costs are lower compared to suspension design used so far. (J.B.)

  1. BWR series pump recirculation system

    International Nuclear Information System (INIS)

    Dillmann, C.W.

    1992-01-01

    This patent describes a recirculation system for driving reactor coolant water contained in an annular downcomer defined between a boiling water reactor vessel and a reactor core spaced radially inwardly therefrom. It comprises a plurality of circumferentially spaced second pumps disposed in the downcomer, each including an inlet for receiving from the downcomer a portion of the coolant water as pump inlet flow, and an outlet for discharging the pump inlet flow pressurized in the second pump as pump outlet flow; and means for increasing pressure of the pump inlet flow at the pump inlet including a first pump disposed in series flow with the second pump for first receiving the pump inlet flow from the downcomer and discharging to the second pump inlet flow pressurized in the first pump

  2. High pressure liquid gas pump

    Science.gov (United States)

    Acres, R. L.

    1972-01-01

    Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.

  3. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  4. Electromagnetic pump technology

    International Nuclear Information System (INIS)

    Prabhakar, R.

    1994-01-01

    Fast Breeder Reactors have an important role to play in our nuclear power programme. Liquid metal sodium is used as the coolant for removing fission heat generated in fast reactors and a distinctive physical property of sodium is its high electrical conductivity. This enables application of electromagnetic (EM) pumps, working on same principle as electric motors, for pumping liquid sodium. Due to its lower efficiency as compared to centrifugal pumps, use of EM pumps has been restricted to reactor auxiliary circuits and experimental facilities. As part of our efforts to manufacture fast reactor components indigenously, work on the development of two types of EM pumps namely flat linear induction pump (FLIP) and annular linear induction pump (ALIP) has been undertaken. Design procedures based on an equivalent circuit approach have been established and results from testing a 5.6 x 10E-3 Cum/s (20 Cum/h) FLIP in a sodium loop were used to validate the procedure. (author). 7 refs., 6 figs

  5. Heat recovery from wastewater systems; Waermerueckgewinnung aus Abwassersystemen

    Energy Technology Data Exchange (ETDEWEB)

    Wanner, O.

    2004-07-01

    Wastewater contains large amounts of heat energy which can be recovered by means of a heat pump and a heat exchanger installed in the sewer system. Practical problems, which may arise and have been investigated in this research project, are the reduction of the heat transfer efficiency due to heat exchanger fouling and the reduction of the nitrification capacity of downstream wastewater treatment plants due to lower wastewater temperatures. A mathematical model was developed by which the decrease of the wastewater temperature in the treatment plant influent can be determined as a function of the amount of heat energy gathered from the wastewater in the sewer system. By this model the variation in time and space of the wastewater temperature in a sewer pipe is calculated for given hydraulics, geometry and environmental conditions. By analysis of data from a large wastewater treatment plant and simulations with a calibrated model, the effect of lowered influent temperatures on nitrification safety, total nitrogen removal efficiency and ammonium effluent concentrations could be quantified. A procedure is suggested by which the reserve nitrification capacity of an existing treatment plant and the increase of the ammonium effluent concentration resulting from a permanent decrease of the wastewater influent temperature can be estimated. By experiments with a pilot scale heat exchanger in a small wastewater channel, the significance of parameters known to have an effect on fouling was investigated and measures to reduce fouling were tested. The measures tested included controlled variation of the wastewater flow velocity (flushing), coatings and finish of the heat exchanger surface and obstacles mounted on the surface. The best results were obtained by regular short term increases of the flow velocity. By this measure, the efficiency of the fouled heat exchanger, which on the average was 60% of the efficiency of the clean heat exchanger, could repeatedly be raised to an

  6. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  7. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  8. Gas fired heat pumps

    International Nuclear Information System (INIS)

    Seifert, M.

    2006-01-01

    The condensing gas boiler is now state of the art and there is no more room for improvement in performance, technically speaking. The next logical step to improve the overall efficiency is to exploit ambient heat in combination with the primary source of energy, natural gas. That means using natural-gas driven heat pumps and gas-fired heat pumps. Based on this, the Swiss Gas Industry decided to set up a practical test programme enjoying a high priority. The aim of the project 'Gas-fired heat pump practical test' is to assess by field tests the characteristics and performance of the foreign serial heat pumps currently on the market and to prepare and promote the introduction on the market place of this sustainable natural-gas technology. (author)

  9. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  10. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  11. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  12. Mechanical vaccum pumps

    CERN Document Server

    Chew, A D

    2007-01-01

    This presentation gives an overview of the technology of contemporary primary and secondary mechanical vacuum pumps. For reference a brief history of vacuum and a summary of important and basic vacuum concepts are first presented.

  13. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.; Abdelghany, Mohamed A.; Elsayed, Mohannad Yomn; Elshurafa, Amro M; Salama, Khaled N.

    2014-01-01

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  14. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  15. GAS METERING PUMP

    Science.gov (United States)

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  16. JET pump limiter

    International Nuclear Information System (INIS)

    Sonnenberg, K.; Deksnis, E.; Shaw, R.; Reiter, D.

    1988-01-01

    JET plans to install two pump limiter modules which can be used for belt-limiter, inner-wall and X-point discharges and, also, for 1-2s as the main limiter. A design is presented which is compatible with two diagnostic systems, and which allows partial removal of the pump limiter to provide access for remote-handling operations. The high heat-flux components are initially cooled during a pulse. Heat is removed between discharges by radiation and pressure contacts to a water-cooled support structure. The pumping edge will be made of annealed pyrolytic graphite. Exhaust efficiency has been estimated, for a 1-d edge model, using a Monte-Carlo calculation of neutral gas transport. When the pump limiter is operated together with other wall components we expect an efficiency of ≅ 5% (2.5 x 10 21 part/s). As a main limiter the efficiency increases to about 10%. (author)

  17. Types of Breast Pumps

    Science.gov (United States)

    ... called a bicycle horn pump, consists of a hollow rubber ball attached to a breast-shield. Some ... and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1-888- ...

  18. Optically pumped laser systems

    International Nuclear Information System (INIS)

    DeMaria, A.J.; Mack, M.E.

    1975-01-01

    Laser systems which are pumped by an electric discharge formed in a gas are disclosed. The discharge is in the form of a vortex stabilized electric arc which is triggered with an auxiliary energy source. At high enough repetition rates residual ionization between successive pulses contributes to the pulse stabilization. The arc and the gain medium are positioned inside an optical pumping cavity where light from the arc is coupled directly into the gain medium

  19. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  20. Resorption heat pump

    International Nuclear Information System (INIS)

    Vasiliev, L.L.; Mishkinis, D.A.; Antukh, A.A.; Kulakov, A.G.; Vasiliev, L.L.

    2004-01-01

    Resorption processes are based on at least two solid-sorption reactors application. The most favorable situation for the resorption heat pumps is the case, when the presence of a liquid phase is impossible. From simple case--two reactors with two salts to complicated system with two salts + active carbon fiber (fabric) and two branch of the heat pump acting out of phase to produce heat and cold simultaneously, this is the topic of this research program

  1. Portable photovoltaic irrigation pumps

    Energy Technology Data Exchange (ETDEWEB)

    Furber, J. D.

    1980-07-01

    Experiences in developing a solar-powered irrigation pump to meet the needs of poor farmers in developing nations are summarized. The design which evolved is small and portable, employing a high-efficiency electric pump, powered by photovoltaic panels. Particular emphasis is placed on how the system works, and on early field problems experienced with the first prototypes. The resolution of these problems and the performance of actual systems in various countries is presented and user responses are noted.

  2. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.

    1984-05-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  3. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.; California Univ., Los Angeles

    1984-01-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6 MW of auxiliary neutral beam heating. Experiments have also been performed with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scrape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a regime may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this 'Z-mode' of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described. (orig.)

  4. Energy efficiency in pumps

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, Durmus; Yagmur, E. Alptekin [TUBITAK-MRC, P.O. Box 21, 41470 Gebze, Kocaeli (Turkey); Yigit, K. Suleyman; Eren, A. Salih; Celik, Cenk [Engineering Faculty, Kocaeli University, Kocaeli (Turkey); Kilic, Fatma Canka [Department of Air Conditioning and Refrigeration, Kocaeli University, Kullar, Kocaeli (Turkey)

    2008-06-15

    In this paper, ''energy efficiency'' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems. (author)

  5. Energy efficiency in pumps

    International Nuclear Information System (INIS)

    Kaya, Durmus; Yagmur, E. Alptekin; Yigit, K. Suleyman; Kilic, Fatma Canka; Eren, A. Salih; Celik, Cenk

    2008-01-01

    In this paper, 'energy efficiency' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems

  6. Pump trials for charged liquids

    International Nuclear Information System (INIS)

    Moroni, J.C.; Niver, A.

    1964-01-01

    The pumps intended for the circulation of charged and radioactive liquids have particular qualities. The choice of such a pump has called for endurance tests with various types of equipment: a Goodyear volumetric screw pumps, and RICHIER, Klein and SCHABAVER centrifugal pumps. The latter, fitted with a special oakum, gave the best results. (authors) [fr

  7. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the

  8. Pumps in nuclear power plants

    International Nuclear Information System (INIS)

    Kim, J.H.

    1991-01-01

    This paper reports that pumps play an important role in nuclear plant operation. For instance, reactor coolant pumps (RCPs) should provide adequate cooling for reactor core in both normal operation and transient or accident conditions. Pumps such as Low Pressure Safety Injection (LPSI) pump in the Emergency Core Cooling System (ECCS) play a crucial role during an accident, and their reliability is of paramount importance. Some key issues involved with pumps in nuclear plant system include the performance of RCP under two-phase flow conditions, piping vibration due to pump operating in two-phase flows, and reliability of LPSI pumps

  9. Inservice testing of vertical pumps

    International Nuclear Information System (INIS)

    Cornman, R.E. Jr.; Schumann, K.E.

    1994-01-01

    This paper focuses on the problems that may occur with vertical pumps while inservice tests are conducted in accordance with existing American Society of Mechanical Engineers Code, Section XI, standards. The vertical pump types discussed include single stage, multistage, free surface, and canned mixed flow pumps. Primary emphasis is placed on the hydraulic performance of the pump and the internal and external factors to the pump that impact hydraulic performance. In addition, the paper considers the mechanical design features that can affect the mechanical performance of vertical pumps. The conclusion shows how two recommended changes in the Code standards may increase the quality of the pump's operational readiness assessment during its service life

  10. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  11. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  12. Review: Findeisen, Genia: Frauen in Indonesien: Geschlechtergleichheit durch Demokratisierung? Eine Analyse des Demokratisierungsprozesses aus Frauenperspektive (2008 Buchbesprechung: Findeisen, Genia: Frauen in Indonesien: Geschlechtergleichheit durch Demokratisierung? Eine Analyse des Demokratisierungsprozesses aus Frauenperspektive (2008

    Directory of Open Access Journals (Sweden)

    Carola von der Dick

    2009-04-01

    Full Text Available Review of the monograph: Findeisen, Genia: Frauen in Indonesien: Geschlechtergleichheit durch Demokratisierung? Eine Analyse des Demokratisierungsprozesses aus Frauenperspektive Wettenberg: Johannes Herrmann J&J Verlag, 2008, ISBN 978-3-937983-11-0, 434 pages Besprechung der Monographie: Findeisen, Genia: Frauen in Indonesien: Geschlechtergleichheit durch Demokratisierung? Eine Analyse des Demokratisierungsprozesses aus Frauenperspektive Wettenberg: Johannes Herrmann J&J Verlag, 2008, ISBN 978-3-937983-11-0, 434 Seiten

  13. Possible emissions from electricity generation from geothermal energy; Moegliche Emissionen bei der Stromerzeugung aus Geothermie

    Energy Technology Data Exchange (ETDEWEB)

    Heberle, Florian; Bruggemann, Dieter [Bayreuth Univ. (Germany). Lehrstuhl fuer Technische Thermodynamik und Transportprozesse (LTTT)

    2013-03-15

    Electricity from geothermal energy in the low temperature range can be efficiently recovered if power plant processes are used with organic working fluids. It is inevitable that a small part of the sometimes harmful fluids leaking from the plant - a conflict in the development of climate-friendly renewable energy actually. A short report of the Centre for Energy Technology at the University of Bayreuth, on behalf of UBA quantifies the emissions of fluorinated hydrocarbons for different development scenarios and emission rates. [German] Strom aus Erdwaerme im Niedertemperaturbereich kann effizient gewonnen werden, wenn Kraftwerksprozesse mit organischen Arbeitsmedien einsetzt werden. Dabei ist es nicht zu vermeiden, dass ein kleiner Teil der mitunter klimaschaedlichen Fluide, aus den Anlagen entweicht - ein Zielkonflikt beim Ausbau der eigentlich klimaschonenden erneuerbaren Energie. Ein Kurzgutachten des Zentrums fuer Energietechnik der Universitaet Bayreuth im Auftrag des UBA quantifiziert die Emissionen fluorierter Kohlenwasserstoffe fuer verschiedene Ausbauszenarien und Emissionsraten.

  14. Wet motor geroter fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Wiernicki, M.V.

    1987-05-05

    This patent describes a wet motor gerotor fuel pump for pumping fuel from a fuel source to an internal combustion which consists of: gerotor pump means comprising an inner pump gear, an outer pump gear, and second tang means located on one of the inner and outer pump gears. The second tang means further extends in a second radial direction radially offset from the first radial direction and forms a driving connection with the first tang means such that the fuel pump pumps fuel from the fuel source into the narrow conduit inlet chamber, through the gerotor pump means past the electric motor means into the outlet housing means substantially along the flow axis to the internal combustion engine.

  15. Ärma talu ehitanud Aus Invest mĂŒĂŒdi Panama riiulifirmale maha / Kadri Paas

    Index Scriptorium Estoniae

    Paas, Kadri, 1982-

    2007-01-01

    Ärma talu ehitanud Aus Invest OÜ ei ole maksnud tööde eest kĂ”igile alltöövĂ”tjatele. Proua Evelin Ilvese sĂ”nul on Ermamaa peatöövĂ”tjale kĂ”igi kokkulepitud tööde eest maksnud. 2007. a. mais mĂŒĂŒsid Aivar Aus ja Mait Aus Tartu maakohtu registriosakonna andmetel Aus Invest OÜ Panamal registreeritud riiulifirmale Arliana Enterprises Corp. Vt. samas: NĂ”unik sekkus presidendi teleintervjuusse. Kui telekanali TV3 LĂ”una-Eesti reporter Valgamaal visiidil viibivalt Toomas Hendrik Ilveselt ja proua Evelin Ilveselt Ärma talu ehitusega kaasnenud vĂ”lgade kohta aru pĂ€ris, sekkus kĂ”nelusse presidendi avalike suhete nĂ”unik Toomas Sildam. Vt. ka lk. 10: Urmo Soonvald. Ärma triibulised. Ajakirjanik ootab Ärma talu probleemidega seoses suuremat avalikustamist

  16. Fusion reactor pumped laser

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1988-01-01

    A nuclear pumped laser is described comprising: a toroidal fusion reactor, the reactor generating energetic neutrons; an annular gas cell disposed around the outer periphery of the reactor, the cell including an annular reflecting mirror disposed at the bottom of the cell and an annular output window disposed at the top of the cell; a gas lasing medium disposed within the annular cell for generating output laser radiation; neutron reflector material means disposed around the annular cell for reflecting neutrons incident thereon back into the gas cell; neutron moderator material means disposed between the reactor and the gas cell and between the gas cell and the neutron reflector material for moderating the energy of energetic neutrons from the reactor; converting means for converting energy from the moderated neutrons to energy pumping means for pumping the gas lasing medium; and beam compactor means for receiving output laser radiation from the annular output window and generating a single output laser beam therefrom

  17. ICPP - a collision probability module for the AUS neutronics code system

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1985-10-01

    The isotropic collision probability program (ICPP) is a module of the AUS neutronics code system which calculates first flight collision probabilities for neutrons in one-dimensional geometries and in clusters of rods. Neutron sources, including scattering, are assumed to be isotropic and to be spatially flat within each mesh interval. The module solves the multigroup collision probability equations for eigenvalue or fixed source problems

  18. Exploring traditional aus-type rice for metabolites conferring drought tolerance.

    Science.gov (United States)

    Casartelli, Alberto; Riewe, David; Hubberten, Hans Michael; Altmann, Thomas; Hoefgen, Rainer; Heuer, Sigrid

    2018-01-25

    Traditional varieties and landraces belonging to the aus-type group of rice (Oryza sativa L.) are known to be highly tolerant to environmental stresses, such as drought and heat, and are therefore recognized as a valuable genetic resource for crop improvement. Using two aus-type (Dular, N22) and two drought intolerant irrigated varieties (IR64, IR74) an untargeted metabolomics analysis was conducted to identify drought-responsive metabolites associated with tolerance. The superior drought tolerance of Dular and N22 compared with the irrigated varieties was confirmed by phenotyping plants grown to maturity after imposing severe drought stress in a dry-down treatment. Dular and N22 did not show a significant reduction in grain yield compared to well-watered control plants, whereas the intolerant varieties showed a significant reduction in both, total spikelet number and grain yield. The metabolomics analysis was conducted with shoot and root samples of plants at the tillering stage at the end of the dry-down treatment. The data revealed an overall higher accumulation of N-rich metabolites (amino acids and nucleotide-related metabolites allantoin and uridine) in shoots of the tolerant varieties. In roots, the aus-type varieties were characterised by a higher reduction of metabolites representative of glycolysis and the TCA cycle, such as malate, glyceric acid and glyceric acid-3-phosphate. On the other hand, the oligosaccharide raffinose showed a higher fold increase in both, shoots and roots of the sensitive genotypes. The data further showed that, for certain drought-responsive metabolites, differences between the contrasting rice varieties were already evident under well-watered control conditions. The drought tolerance-related metabolites identified in the aus-type varieties provide a valuable set of protective compounds and an entry point for assessing genetic diversity in the underlying pathways for developing drought tolerant rice and other crops.

  19. Use of Vegetation Health Data for Estimation of Aus Rice Yield in Bangladesh

    OpenAIRE

    Rahman, Atiqur; Roytman, Leonid; Krakauer, Nir Y.; Nizamuddin, Mohammad; Goldberg, Mitch

    2009-01-01

    Rice is a vital staple crop for Bangladesh and surrounding countries, with interannual variation in yields depending on climatic conditions. We compared Bangladesh yield of aus rice, one of the main varieties grown, from official agricultural statistics with Vegetation Health (VH) Indices [Vegetation Condition Index (VCI), Temperature Condition Index (TCI) and Vegetation Health Index (VHI)] computed from Advanced Very High Resolution Radiometer (AVHRR) data covering a period of 15 years (1991...

  20. Potentiale und Barrieren der Nutzung des Mobile Payment aus Kundensicht: eine empirische Untersuchung

    OpenAIRE

    Haarstick, Felix

    2016-01-01

    WÀhrend sich das Zahlungsverfahren Mobile Payment seit einigen Jahren international mehr und mehr etabliert, fristet es entgegen jÀhrlich wiederkehrender Erfolgsprognosen in Deutschland immer noch ein Nischendasein. Die vorliegende Untersuchung entstand im Rahmen einer Bachelorarbeit des Studiengangs der Betriebswirtschaftslehre an der Hochschule Hannover und beschÀftigt sich mit den Potentialen und Barrieren der Nutzung des Mobile Payment aus Kundensicht, mit dem Ziel, die wesentlichen Fakto...

  1. Production of an aluminium heat exchanger coil; Fertigung eines gewickelten Waermetauschers aus Aluminium

    Energy Technology Data Exchange (ETDEWEB)

    Wimmer, G. [Linde AG, Tacherting (Germany)

    2002-07-01

    The heat exchangers presented in this contribution are the liquefier and subcooler of a two-component natural gas liquefaction plant to be exported to Australia, with a total heat exchanger surface that corresponds to the area of 8 soccer fields. [German] Bei den vorgestellten Waermetauschern handelt es sich um Liquefier und Subcooler einer aus 2 Prozesseinheiten bestehenden Erdgasverfluessigungsanlage fuer Australien, mit einer Gesamt-Waermeaustauschflaeche vergleichbar mit der Groesse von 8 Fussballfeldern. (orig.)

  2. AUS diffusion module POW checkout - 1- and 2-dimensional kinetics calculations

    International Nuclear Information System (INIS)

    Pollard, J.P.

    1977-01-01

    POW is the diffusion module 'workhorse' of the AUS reactor neutronics modular code system; its steady state calculations have been checked out against other diffusion codes (particularly CRAM and GOG). Checkout of kinetic aspects, however, is difficult as kinetic codes are not freely available. In this report POW has been checked against three benchmark calculations as well as a calculation on the 100 KW Argonaut reactor Moata. (author)

  3. Behandlung von Essstörungen bei Jugendlichen aus Sicht der kinder- und jugendpsychiatrischen Klinik

    OpenAIRE

    Pfeiffer, Ernst; Hansen, Berit; Korte, Alexander; Lehmkuhl, Ulrike

    2005-01-01

    Der Beitrag stellt - im Sinne klinischer Leitlinien - die aktuelle Praxis einer auf die Behandlung von Essstörungen spezialisierten UniversitĂ€tsklinik fĂŒr Kinder- und Jugendpsychiatrie dar. Die Notwendigkeit eines multimodalen Therapiekonzeptes wird betont, bestehend aus Maßnahmen zur Normalisierung von Gewicht und Essverhalten, HeilpĂ€dagogik, einzel-, gruppen- und familienbezogener Psychotherapie, ergĂ€nzt durch Körper-, Kunst- und Musiktherapie und ggf. Psychopharmakotherapie. Abschlie...

  4. Single perineal incision placement of artificial urinary sphincter with cadaveric correlation of sub-dartos pump placement

    Directory of Open Access Journals (Sweden)

    Cooper R. Benson

    Full Text Available ABSTRACT Purpose We present a novel AUS implantation technique using a single perineal incision for single device placement or in combination with an inflatable penile prosthesis (IPP. Urinary and sexual dysfunction following the management of prostate cancer has a significant impact on the quality of life of our patients. While there are marginal changes in the prosthetic devices, we strive to reduce post-operative morbidity while maximizing efficacy. Materials and Methods We retrospectively reviewed the outcomes of 6 patients who underwent single perineal incision placement of a virgin AUS in 2014, 3 with simultaneous IPP placement. In all cases, the pressure regulating balloons (PRB were placed in a high sub-muscular ectopic position and the pumps were placed into a sub-dartos pouch through the perineal incision, which was also validated using a cadaveric model. Results The mean patient age was 61 (SD, 7.5 years with mean body mass index of 31 (SD, 5.9. The average pre-operative pad usage was 7.7 (SD 1.63 pads per day. The mean follow-up was 13.9 months (SD 9.45. Four out of the six patients reported utilizing ≀1 pad daily at follow-up. The one patient who was not initially dry required downsizing of his cuff to 3.5cm; the remaining patient was lost to follow-up. There were no identifiable perioperative or post-operative complications. Conclusions We present our initial report of using a single perineal incision for AUS implantation with a validated sub-dartos pump location, which is safe and effective for implantation of an AUS as a single or double implantation in well-selected patients.

  5. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  6. Acoustical heat pumping engine

    Science.gov (United States)

    Wheatley, J.C.; Swift, G.W.; Migliori, A.

    1983-08-16

    The disclosure is directed to an acoustical heat pumping engine without moving seals. A tubular housing holds a compressible fluid capable of supporting an acoustical standing wave. An acoustical driver is disposed at one end of the housing and the other end is capped. A second thermodynamic medium is disposed in the housing near to but spaced from the capped end. Heat is pumped along the second thermodynamic medium toward the capped end as a consequence both of the pressure oscillation due to the driver and imperfect thermal contact between the fluid and the second thermodynamic medium. 2 figs.

  7. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  8. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  9. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  10. Carbon sheet pumping

    International Nuclear Information System (INIS)

    Ohyabu, N.; Sagara, A.; Kawamura, T.; Motojima, O.; Ono, T.

    1993-07-01

    A new hydrogen pumping scheme has been proposed which controls recycling of the particles for significant improvement of the energy confinement in toroidal magnetic fusion devices. In this scheme, a part of the vacuum vessel surface near the divertor is covered with carbon sheets of a large surface area. Before discharge initiation, the sheets are baked up to 700 ∌ 1000degC to remove the previously trapped hydrogen atoms. After being cooled down to below ∌ 200degC, the unsaturated carbon sheets trap high energy charge exchange hydrogen atoms effectively during a discharge and overall pumping efficiency can be as high as ∌ 50 %. (author)

  11. High-performance GFRP materials with glass fibre prepregs; Hochleistungs-Faserverbundwerkstoffe aus UD-Gelegeprepregs

    Energy Technology Data Exchange (ETDEWEB)

    Prause, J.P. [Schichtstoff-Technik, Arnsberg (Germany); Schroeder, K.F. [Wissenschaftliche Verlagsanstalt, Mettmann (Germany)

    1999-07-01

    The US 3M Company is the producer of the 'Scotchply' glass fibre prepreg which results in materials that can withstand higher dynamic loads than conventional glass fibre reinforced plastics. The new materials are used, e.g., for leaf spring construction. The fatigue characteristics of GFRP leaf springs were discussed at the DGM 'Verbundwerkstoffe und Werkstoffverbunde' conference at Kaiserslauter in September 1997. This contribution presents tools for the engineer for calculation of leaf springs in consideration of the expected loads. [German] Bereits frueher konnte nachgewiesen werden, dass mit Glasgarngelegen verstaerkte Kunststoffe dynamisch hoeher beansprucht werden koennen als gleichartige Konstruktionen mit Glasgewebeverstaerkung. Dieser Vorteil wird in der industriellen Praxis genutzt, um den breiten Einsatzbereich von Blattfedern aus Stahl durch solche aus Faserverbundwerkstoffen zu erweitern. Mit Glasfasern verstaerkte Kunststoffe (GFK) sind seit Jahren Stand der Technik. Die Verarbeitung als Gelegeprepreg hat sich oekonomisch und oekologisch als eine guenstige Technologie bewaehrt. Die Prepregs werden im Wickelverfahren in die endgueltige Form gebracht oder zu Platten verpresst, aus denen die gewuenschten Werkstuecke mechanisch herausgearbeitet werden. Eine ideale Ausnutzung aller in UD-Gelegen vorgegebenen Eigenschaften ist die Form der Blattfeder. Werkstoff und Geometrie koennen optimal an die Belastung angepasst werden. Ueber die Ermuedungsfestigkeit von GFK-Blattfedern wurde waehrend der Vortragstagung der DGM 'Verbundwerkstoffe und Werkstoffverbunde' im September 1997 in Kaiserslautern eingehend berichtet. Mit dieser Veroeffentlichung soll dem Ingenieur eine Hilfe gegeben werden, solche Blattfedern entsprechend der spaeteren Beanspruchung zu berechnen. (orig.)

  12. InternationalitĂ€t in Gender Studies – Reflexionen aus Indien und der TĂŒrkei

    Directory of Open Access Journals (Sweden)

    Dörte Segebart

    2013-07-01

    Full Text Available Der audiovisuelle Beitrag InternationalitĂ€t in Gender Studies – Reflexionen aus Indien und der TĂŒrkei stellt durch die Darstellung sehr persönlicher individueller Sichtweisen und Erfahrungen die Spannbreite von Positionen zum Thema dar. Theoretische Reflexionen werden nicht unbedingt untermauert, aber auch nicht negiert. Der Beitrag will innerhalb des Jahrbuchs daran erinnern, dass hinter den theoretischen Debatten Menschen stehen, die sich miteinander austauschen und auseinandersetzen wollen. Multidirektionale Transfers sind erwĂŒnscht sowie eine stĂ€ndige kritische Auseinandersetzung ĂŒber das Wie. Duygu Aloglu aus Ankara, TĂŒrkei und Lavinia Mawlong aus Shillong und Mumbai, Indien promovieren am Institut fĂŒr Geographische Wissenschaften an der FU Berlin. Sie sprechen ĂŒber ihre persönliche Sichtweise auf das Thema Internationalisierung von Gender Studies, fokussieren speziell auf die Situation in der TĂŒrkei und in Indien und betten dies in ihren eigenen persönlichen Hintergrund ein. Die Interviews wurden auf Englisch und separat gefĂŒhrt. Sie sind im Film zusammengefĂŒgt worden.

  13. Use of vegetation health data for estimation of aus rice yield in bangladesh.

    Science.gov (United States)

    Rahman, Atiqur; Roytman, Leonid; Krakauer, Nir Y; Nizamuddin, Mohammad; Goldberg, Mitch

    2009-01-01

    Rice is a vital staple crop for Bangladesh and surrounding countries, with interannual variation in yields depending on climatic conditions. We compared Bangladesh yield of aus rice, one of the main varieties grown, from official agricultural statistics with Vegetation Health (VH) Indices [Vegetation Condition Index (VCI), Temperature Condition Index (TCI) and Vegetation Health Index (VHI)] computed from Advanced Very High Resolution Radiometer (AVHRR) data covering a period of 15 years (1991-2005). A strong correlation was found between aus rice yield and VCI and VHI during the critical period of aus rice development that occurs during March-April (weeks 8-13 of the year), several months in advance of the rice harvest. Stepwise principal component regression (PCR) was used to construct a model to predict yield as a function of critical-period VHI. The model reduced the yield prediction error variance by 62% compared with a prediction of average yield for each year. Remote sensing is a valuable tool for estimating rice yields well in advance of harvest and at a low cost.

  14. Use of Vegetation Health Data for Estimation of Aus Rice Yield in Bangladesh

    Directory of Open Access Journals (Sweden)

    Mohammad Nizamuddin

    2009-04-01

    Full Text Available Rice is a vital staple crop for Bangladesh and surrounding countries, with interannual variation in yields depending on climatic conditions. We compared Bangladesh yield of aus rice, one of the main varieties grown, from official agricultural statistics with Vegetation Health (VH Indices [Vegetation Condition Index (VCI, Temperature Condition Index (TCI and Vegetation Health Index (VHI] computed from Advanced Very High Resolution Radiometer (AVHRR data covering a period of 15 years (1991–2005. A strong correlation was found between aus rice yield and VCI and VHI during the critical period of aus rice development that occurs during March-April (weeks 8–13 of the year, several months in advance of the rice harvest. Stepwise principal component regression (PCR was used to construct a model to predict yield as a function of critical-period VHI. The model reduced the yield prediction error variance by 62% compared with a prediction of average yield for each year. Remote sensing is a valuable tool for estimating rice yields well in advance of harvest and at a low cost.

  15. Vacuum pumping concepts for ETF

    International Nuclear Information System (INIS)

    Homeyer, W.G.

    1980-09-01

    The Engineering Test Facility (ETF) poses unique vacuum pumping requirements due to its large size and long burn characteristics. These requirements include torus vacuum pumping initially and between burns and pumping of neutralized gas from divertor collector chambers. It was found that the requirements could be met by compound cryopumps in which molecular sieve 5A is used as the cryosorbent. The pumps, ducts, and vacuum valves required are large but fit with other ETF components and do not require major advances in vacuum pumping technology. Several additional design, analytical, and experimental studies were identified as needed to optimize designs and provide better design definition for the ETF vacuum pumping systems

  16. Study of Hydrogen Pumping through Condensed Argon in Cryogenic pump

    International Nuclear Information System (INIS)

    Jadeja, K A; Bhatt, S B

    2012-01-01

    In ultra high vacuum (UHV) range, hydrogen is a dominant residual gas in vacuum chamber. Hydrogen, being light gas, pumping of hydrogen in this vacuum range is limited with widely used UHV pumps, viz. turbo molecular pump and cryogenic pump. Pre condensed argon layers in cryogenic pump create porous structure on the surface of the pump, which traps hydrogen gas at a temperature less than 20° K. Additional argon gas injection in the cryogenic pump, at lowest temperature, generates multiple layers of condensed argon as a porous frost with 10 to 100 A° diameters pores, which increase the pumping capacity of hydrogen gas. This pumping mechanism of hydrogen is more effective, to pump more hydrogen gas in UHV range applicable in accelerator, space simulation etc. and where hydrogen is used as fuel gas like tokamak. For this experiment, the cryogenic pump with a closed loop refrigerator using helium gas is used to produce the minimum cryogenic temperature as ∌ 14° K. In this paper, effect of cryosorption of hydrogen is presented with different levels of argon gas and hydrogen gas in cryogenic pump chamber.

  17. The speed dependence of dry running screw type vacuum pumps; Die Drehzahlabhaengigkeit trockenlaufender Schraubenspindel-Vakuumpumpen

    Energy Technology Data Exchange (ETDEWEB)

    Kauder, K.; Rohe, A. [Univ. Dortmund (Germany). FG Fluidenergiemaschinen

    2003-07-01

    This contribution describes the development of a simple mathematical approach, which has the primary aim of describing the speed dependence of maximum vacuum of a screw type vacuum pump. Based on a simple positive displacement model assuming an isothermal process and with gas flow through an orifice used to depict the clearance mass flows, the vacuum achieved is calculated as function of rotor speed. Changes in the model's approaches, in particular the number of stages and the transition of viscose flow to molecular flow, enable us to depict the characteristic working behaviour of a screw type vacuum pump from the point of view of its maximum vacuum. An extension of this approach yields the characteristics of the delivery rate as a function of the suction pressure. If we replace the orifice flow with the transition flow it becomes possible to describe the characteristic maximum of suction speed at moderate inlet pressures, which can definitely be ascribed to increasing throttling during the transition of the viscose to the molecular flow type. Where there are larger discrepancies, continuous comparison of calculated with measured characteristics requires analyses of the sensitivity of this approach regarding the gap clearances, and a mathematical consideration of external leakages. Finally the effects of internal compression on working behaviour are calculated by using the algorithm. Even if the potential of this approach can not be completely realised due to unknown boundary condition in the examined machine, it nevertheless yields clear and explicable data about the influences of working and construction parameters on the working behaviour. (orig.) [German] Der vorgelegte Beitrag beschreibt einen einfachen mathematischen Ansatzes, der als primaeres Ziel verfolgt, die signifikante Drehzahlabhaengigkeit des Enddruckes von Schraubenspindel-Vakuumpumpen zu berechnen. Ausgehend vom einfachen Verdraengermaschinenmodell werden zunaechst mit Hilfe eines einstufigen

  18. Solar pumped laser

    Science.gov (United States)

    Lee, J. H.; Hohl, F.; Weaver, W. R. (Inventor)

    1984-01-01

    A solar pumped laser is described in which the lasant is a gas that will photodissociate and lase when subjected to sunrays. Sunrays are collected and directed onto the gas lasant to cause it to lase. Applications to laser propulsion and laser power transmission are discussed.

  19. Cryogenic vacuum pump design

    International Nuclear Information System (INIS)

    Bartlett, A.J.; Lessard, P.A.

    1984-01-01

    This paper is a review of the problems and tradeoffs involved in cryogenic vacuum pump analysis, design and manufacture. Particular attention is paid to the several issues unique to cryopumps, e.g., radiation loading, adsorption of noncondensible gases, and regeneration. A general algorithm for cryopump design is also proposed. 12 references

  20. Pump monitoring and analysis

    International Nuclear Information System (INIS)

    Guy, K.R.

    1992-01-01

    The paper describes how to set up a periodic vibration monitoring program implemented with electronic data loggers. Acquired data will be analyzed and evaluated to determine pump condition. Periodic measuring frequency, reporting procedures, and conditions of mechanical components are discussed in detail based on the actual case study

  1. Magnetic-flux pump

    Science.gov (United States)

    Hildebrandt, A. F.; Elleman, D. D.; Whitmore, F. C. (Inventor)

    1966-01-01

    A magnetic flux pump is described for increasing the intensity of a magnetic field by transferring flux from one location to the magnetic field. The device includes a pair of communicating cavities formed in a block of superconducting material, and a piston for displacing the trapped magnetic flux into the secondary cavity producing a field having an intense flux density.

  2. Putzmeister pumps for Tchernobyl

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Self-propelling concrete pumps are briefly described in this article, they comprise a 52-meter boom, a radiation protection, remote control, videocameras. Several units were ordered by the Soviet Union. The truck cabin is protected against radiation by a 10 millimeter thick shield in lead. 3 photographs [fr

  3. Scroll vacuum pump

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Etsuo; Suganami, Takuya; Nishida, Mitsuhiro; Kitora, Yoshihisa; Yamamoto, Sakuei; Fujii, Kosaburo

    1988-02-25

    An effort is made to apply a scroll machine to development of a vacuum pump. In view of mechanical simplification and load patterns, the vacuum pump uses a rotating mechanism to produce paired vortices rotating around each center. Chip seal and atmospheric pressure are utilized for axial gap sealing while a spring and atmospheric pressure for the radial gap sealing. In both gaps, the sealing direction is stationary relative to the environment during rotation, making it much easier to achieve effective sealing as compared to oscillating pumps. Since the compression ratio is high in vacuum pumps, a zero top clearance form is adopted for the central portion of vortices and an gas release valve is installed in the rotating axis. A compact Oldham coupling with a small inertia force is installed behind the vortices to maintain the required phase relations between the vortices. These improvements result in a vacuum of 1 Pa for dry operation and 10/sup -2/ Pa for oil flooded operation of a single-stage scroll machine at 1800 rpm. (5 figs, 1 tab, 4 refs)

  4. Centrifugal blood pump 603

    Indian Academy of Sciences (India)

    Centrifugal blood pump 603 pressure obtained for real blood, as shown in figure 6, is a little higher than that for glycerin aqua Solution with the same viscosity as blood. This may indicate the effect of slight non-. Newtonian turbulent flow. The radial whirl motion of the impeller was observed by dual laser position sensors.

  5. Impulse pumping modelling and simulation

    International Nuclear Information System (INIS)

    Pierre, B; Gudmundsson, J S

    2010-01-01

    Impulse pumping is a new pumping method based on propagation of pressure waves. Of particular interest is the application of impulse pumping to artificial lift situations, where fluid is transported from wellbore to wellhead using pressure waves generated at wellhead. The motor driven element of an impulse pumping apparatus is therefore located at wellhead and can be separated from the flowline. Thus operation and maintenance of an impulse pump are facilitated. The paper describes the different elements of an impulse pumping apparatus, reviews the physical principles and details the modelling of the novel pumping method. Results from numerical simulations of propagation of pressure waves in water-filled pipelines are then presented for illustrating impulse pumping physical principles, and validating the described modelling with experimental data.

  6. Reactor recirculation pump test loop

    International Nuclear Information System (INIS)

    Taka, Shusei; Kato, Hiroyuki

    1979-01-01

    A test loop for a reactor primary loop recirculation pumps (PLR pumps) has been constructed at Ebara's Haneda Plant in preparation for production of PLR pumps under license from Byron Jackson Pump Division of Borg-Warner Corporation. This loop can simulate operating conditions for test PLR pumps with 130 per cent of the capacity of pumps for a 1100 MWe BWR plant. A main loop, primary cooling system, water demineralizer, secondary cooling system, instrumentation and control equipment and an electric power supply system make up the test loop. This article describes the test loop itself and test results of two PLR pumps for Fukushima No. 2 N.P.S. Unit 1 and one main circulation pump for HAZ Demonstration Test Facility. (author)

  7. AUS, Neutron Transport and Gamma Transport System for Fission Reactors and Fusion Reactors

    International Nuclear Information System (INIS)

    1990-01-01

    1 - Description of program or function: AUS is a neutronics code system which may be used for calculations of a wide range of fission reactors, fusion blankets and other neutron applications. The present version, AUS98, has a nuclear cross section library based on ENDF/B-VI and includes modules which provide for reactor lattice calculations, one-dimensional transport calculations, multi-dimensional diffusion calculations, cell and whole reactor burnup calculations, and flexible editing of results. Calculations of multi-region resonance shielding, coupled neutron and photon transport, energy deposition, fission product inventory and neutron diffusion are combined within the one code system. The major changes from the previous release, AUS87, are the inclusion of a cross-section library based on ENDF/B-VI, the addition of the POW3D multi-dimensional diffusion module, the addition of the MICBURN module for controlling whole reactor burnup calculations, and changes to the system as a consequence of moving from IBM mainframe computers to UNIX workstations. 2 - Method of solution: AUS98 is a modular system in which the modules are complete programs linked by a path given in the input stream. A simple path is simply a sequence of modules, but the path is actually pre-processed and compiled using the Fortran 77 compiler. This provides for complex module linking if required. Some of the modules included in AUS98 are: MIRANDA Cross-section generation in a multi-region resonance subgroup calculation and preliminary group condensation. ANAUSN One-dimensional discrete ordinates calculation. ICPP Isotropic collision probability calculation in one dimension and for rod clusters. POW3D Multi-dimensional neutron diffusion calculation including feedback-free kinetics. AUSIDD One-dimensional diffusion calculation. EDITAR Reaction-rate editing and group collapsing following a transport calculation. CHAR Lattice and global burnup calculation. MICBURN Control of global burnup

  8. Sludge pumping in water treatment

    International Nuclear Information System (INIS)

    Solar Manuel, M. A.

    2010-01-01

    In water treatment processes is frequent to separate residual solids, with sludge shape, and minimize its volume in a later management. the technologies to applicate include pumping across pipelines, even to long distance. In wastewater treatment plants (WWTP), the management of these sludges is very important because their characteristics affect load losses calculation. Pumping sludge can modify its behavior and pumping frequency can concern treatment process. This paper explains advantages and disadvantages of different pumps to realize transportation sludge operations. (Author) 11 refs.

  9. Vivitron dead section pumping tests

    International Nuclear Information System (INIS)

    Heugel, J.; Bayet, J.P.; Brandt, C.; Delhomme, C.; Krieg, C.; Kustner, F.; Meiss, R.; Riehl, R.; Roth, C.; Schlewer, B.; Six, P.; Weber, A.

    1990-10-01

    Pumping tests have been conducted on a simulated accelerator dead section. The behavior of different pump types are compared and analyzed. Vacuum conditions to be expected in the Vivitron are reached and several parameters are verified. Selection of a pump for the Vivitron dead section is confirmed

  10. Heat pumps are a dream

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    The fact that heat pumps do not achieve what their manufacturers promise in costs efficiency has been realized by the market. In 1981 the sales of heat pumps decreased by 50% of the 1980 market. Public utilities give the reason as economic, since fuel oil is too cheap. The author refutes this argument and presents arguments against heat pumps.

  11. Pumping characteristics of roots blower pumps for light element gases

    International Nuclear Information System (INIS)

    Hiroki, Seiji; Abe, Tetsuya; Tanzawa, Sadamitsu; Nakamura, Jun-ichi; Ohbayashi, Tetsuro

    2002-07-01

    The pumping speed and compression ratio of the two-stage roots blower pumping system were measured for light element gases (H 2 , D 2 and He) and for N 2 , in order to assess validity of the ITER torus roughing system as an ITER R and D task (T234). The pumping system of an Edwards EH1200 (nominal pumping speed of 1200 m 3 /s), two EH250s (ibid. 250 m 3 /s) and a backing pump (ibid. 100 m 3 /s) in series connection was tested under PNEUROP standards. The maximum pumping speeds of the two-stage system for D 2 and N 2 were 1200 and 1300 m 3 /h, respectively at 60 Hz, which satisfied the nominal pumping speed. These experimental data support the design validity of the ITER torus roughing system. (author)

  12. Electroosmotic pumps for microflow analysis

    Science.gov (United States)

    Wang, Xiayan; Wang, Shili; Gendhar, Brina; Cheng, Chang; Byun, Chang Kyu; Li, Guanbin; Zhao, Meiping; Liu, Shaorong

    2009-01-01

    With rapid development in microflow analysis, electroosmotic pumps are receiving increasing attention. Compared to other micropumps, electroosmotic pumps have several unique features. For example, they are bi-directional, can generate constant and pulse-free flows with flow rates well suited to microanalytical systems, and can be readily integrated with lab-on-chip devices. The magnitude and the direction of flow of an electroosmotic pump can be changed instantly. In addition, electroosmotic pumps have no moving parts. In this article, we discuss common features, introduce fabrication technologies and highlight applications of electroosmotic pumps. PMID:20047021

  13. Bearing for liquid metal pump

    International Nuclear Information System (INIS)

    Dickinson, R.J.; Pennell, W.E.; Wasko, J.

    1984-01-01

    A liquid metal pump bearing support comprises a series of tangentially oriented spokes that connect the bearing cylinder to the pump internals structure. The spokes may be arranged in a plurality of planes extending from the bearing cylinder to the pump internals with the spokes in one plane being arranged alternately with those in the next plane. The bearing support structure provides the pump with sufficient lateral support for the bearing structure together with the capability of accommodating differential thermal expansion without adversely affecting pump performance

  14. Thermo-electric pump

    International Nuclear Information System (INIS)

    Georges, J.-L.; Veyret, J.-F.

    1973-01-01

    Description is given of a thermo-pump for electrically conductive liquid fluids, e.g. for a liquid metal such as sodium. This pump is characterized in that the piping for the circulation of the conductive liquid is constituted by a plurality of conduits defined by two co-axial cylinders and two walls parallel to their axis. Each conduit limited outside by a magnet, inside by a mild-iron tube, and laterally by two materials forming a thermocouple. The electric current generated by that thermo-couple and the magnetic flux generated by the magnets both loop the loop through an outer cylindrical nickel shell. This can be applied to sodium circulation loops for testing nuclear fuel elements [fr

  15. Heat pumps: heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, R

    1976-01-01

    The author firstly explains in a general manner the functioning of the heat pump. Following a brief look at the future heat demand and the possibilities of covering it, the various methods of obtaining energy (making use of solar energy, ground heat, and others) and the practical applications (office heating, swimming pool heating etc.) are explained. The author still sees considerable difficulties in using the heat pump at present on a large scale. Firstly there is not enough maintenance personnel available, secondly the electricity supply undertakings cannot provide the necessary electricity on a wide basis without considerable investments. Other possibilities to save energy or to use waste energy are at present easier and more economical to realize. Recuperative and regenerative systems are described.

  16. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  17. Pocket pumped image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, I.V., E-mail: kotov@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); O' Connor, P. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Murray, N. [Centre for Electronic Imaging, Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2015-07-01

    The pocket pumping technique is used to detect small electron trap sites. These traps, if present, degrade CCD charge transfer efficiency. To reveal traps in the active area, a CCD is illuminated with a flat field and, before image is read out, accumulated charges are moved back and forth number of times in parallel direction. As charges are moved over a trap, an electron is removed from the original pocket and re-emitted in the following pocket. As process repeats one pocket gets depleted and the neighboring pocket gets excess of charges. As a result a “dipole” signal appears on the otherwise flat background level. The amplitude of the dipole signal depends on the trap pumping efficiency. This paper is focused on trap identification technique and particularly on new methods developed for this purpose. The sensor with bad segments was deliberately chosen for algorithms development and to demonstrate sensitivity and power of new methods in uncovering sensor defects.

  18. FTU pump limiter

    International Nuclear Information System (INIS)

    Alessandrini, C.; Ciotti, M.; Mattei, A. De; Maddaluno, G.; Mazzitelli, G.

    1989-01-01

    The control of the refuelling and recycling of the plasma is crucial in providing enhanced performances in tokamaks and steady-state operation in future reactors. In this paper, we report details of the design and analysis for the pump limiter to be incorporated into the FTU tokamak. The FTU, presently under commissioning, is a compact high field (B=8T), medium high density, circular cross section machine with small accesses. The dimensions of the equatorial port (width 8 cm) would reduce the length of the entrance throat to a few centimeters, which is unacceptable for efficient particle trapping. We have, therefore, designed a rotating blade of the pump limiter head that, in the working position, extends in the toroidal direction inside the vacuum chamber. (author) 8 refs., 4 figs

  19. Geothermal heat pump

    International Nuclear Information System (INIS)

    Bruno, R.; Tinti, F.

    2009-01-01

    In recent years, for several types of buildings and users, the choice of conditioning by heat pump and low enthalpy geothermal reservoir has been increasing in the Italian market. In fact, such systems are efficient in terms of energy and consumption, they can perform, even at the same time, both functions, heating and cooling and they are environmentally friendly, because they do not produce local emissions. This article will introduce the technology and will focus on critical points of a geothermal field design, from actual practice, to future perspectives for the geo exchanger improvement. Finally, the article presents a best practice case in Bologna district, with an economic analysis showing the convenience of a geothermal heat pump. Conclusions of the real benefits of these plants can be drawn: compared to a non-negligible initial cost, the investment has a pay-back period almost always acceptable, usually less than 10 years. [it

  20. 21 CFR 880.5725 - Infusion pump.

    Science.gov (United States)

    2010-04-01

    ... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and...

  1. 14 CFR 23.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 23.991 Section 23.991... § 23.991 Fuel pumps. (a) Main pumps. For main pumps, the following apply: (1) For reciprocating engine installations having fuel pumps to supply fuel to the engine, at least one pump for each engine must be directly...

  2. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  3. IRRIGATION USING SOLAR PUMP

    OpenAIRE

    Prof. Nitin P.Choudhary*1 & Ms. Komal Singne2

    2017-01-01

    In this report the described design of a PV and soil moisture sensor based automated irrigation system is introduced. This project aims to provide a human friendly, economical and automated water pumping system which eliminates the problems of over irrigation and helps in irrigation water optimization and manage it in accordance with the availability of water. Our project not only tries to modernize the irrigation practices and ensure the optimum yield by carefully fulfilling the requirements...

  4. Small size ion pumps

    International Nuclear Information System (INIS)

    Cyranski, R.; Kiliszek, Cz.R.; Marks, J.; Sobolewski, A.; Magielko, H.

    2001-01-01

    This paper describes some designs of the two versions ion pumps and their range operation for various magnetic fields. The first version is made with different cell size in the anode element and titanium cathode operating in magnetic field from 600 to 650 Gs and the second version with the same anode element but differential Ti/Ta cathode working in magnetic field above 1200 Gs

  5. Pumping potential wells

    Science.gov (United States)

    Hershkowitz, N.; Forest, C.; Wang, E. Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electro collecting anode in a relatively cold, low density multidipole plasma is considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important.

  6. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, all such structures must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which pump ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density, multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two-dimensional character of the problem is shown to be important

  7. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well, but steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important. (author)

  8. Jet operated heat pump

    International Nuclear Information System (INIS)

    Collard, T.H.

    1982-01-01

    A jet pump system is shown that utilizes waste heat to provide heating and/or cooling. Waste heat diverted through a boiler causes a refrigerant to evaporate and expand for supersonic discharge through a nozzle thereby creating a vacuum in an evaporator coil. The vacuum draws the refrigerant in a gaseous state into a condensing section of a jet pump along with refrigerant from a reservoir in a subcooled liquid form. This causes condensation of the gas in a condensation section of the jet pump, while moving at constant velocity. The change in momentum of the fluid overcomes the system high side pressure. Some of the condensate is cooled by a subcooler. Refrigerant in a subcooled liquid state from the subcooler is fed back into the evaporator and the condensing section with an adequate supply being insured by the reservoir. The motive portion of the condensate is returned to the boiler sans subcooling. By proper valving start-up is insured, as well as the ability to switch from heating to cooling

  9. Controlling groundwater pumping online.

    Science.gov (United States)

    Zekri, Slim

    2009-08-01

    Groundwater over-pumping is a major problem in several countries around the globe. Since controlling groundwater pumping through water flow meters is hardly feasible, the surrogate is to control electricity usage. This paper presents a framework to restrict groundwater pumping by implementing an annual individual electricity quota without interfering with the electricity pricing policy. The system could be monitored online through prepaid electricity meters. This provides low transaction costs of individual monitoring of users compared to the prohibitive costs of water flow metering and monitoring. The public groundwater managers' intervention is thus required to determine the water and electricity quota and watch the electricity use online. The proposed framework opens the door to the establishment of formal groundwater markets among users at very low transaction costs. A cost-benefit analysis over a 25-year period is used to evaluate the cost of non-action and compare it to the prepaid electricity quota framework in the Batinah coastal area of Oman. Results show that the damage cost to the community, if no active policy is implemented, amounts to (-$288) million. On the other hand, the implementation of a prepaid electricity quota with an online management system would result in a net present benefit of $199 million.

  10. Liquid sodium pumps

    International Nuclear Information System (INIS)

    Allen, H.G.

    1985-01-01

    The pump for use in a nuclear reactor cooling system comprises a booster stage impeller for drawing the liquid through the inlet. A diffuser is affixedly disposed within the pump housing to convert the kinetic pressure imparted to the liquid into increased static pressure. A main stage impeller is rotatively driven by a pump motor at a relatively high speed to impart a relatively high static pressure to the liquid and for discharging the liquid at a relatively high static pressure. A hydraulic coupling is disposed remotely from the liquid path for hydraulically coupling the main stage impeller and the booster stage impeller to rotate the booster stage impeller at a relatively low speed to maintain the low net positive suction pressure applied to the liquid at the inlet greater than the vapor pressure of the liquid and to ensure that the low net positive suction heat, as established by the main stage impeller exceeds the vapor pressure. The coupling comprises a grooved drum which rotates between inner and outer drag coupling members. In a modification the coupling comprises a torque converter. (author)

  11. Electrocentrifugal pumping; Bombeo electrocentrifugo

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Perez, Guillermo; Medellin Otero, Hector [Instituto Mexicano del Peroleo (Mexico)

    1996-07-01

    The exploitation of isolated oil deposits, in losing their own energy, enter a phase of secondary recovery. One of the technologies of new development in Mexico is the one of electrocentrifugal pumping , which consists of introducing the motor-pump as an integral part of the production pipe down to the well bottom and pumping directly up to central complexes, from where it is sent inland. In the present paper is intended to explain what this type of secondary recovery consists of. [Spanish] La explotacion de yacimientos aislados de petroleo, al perder su energia propia, entran en una fase de recuperacion secundaria. Una de las tecnologias de nuevo desarrollo en Mexico es la de bombeo electrocentrifugo, la cual consiste en introducir la motobomba como parte integral de la tuberia de produccion hasta el fondo del pozo y bombearlo directamente hasta los complejos centrales, de donde se envia a tierra. En el presente trabajo se pretende explicar en que consiste este tipo de recuperacion secundaria.

  12. Optically pumped terahertz sources

    Institute of Scientific and Technical Information of China (English)

    ZHONG Kai; SHI Wei; XU DeGang; LIU PengXiang; WANG YuYe; MEI JiaLin; YAN Chao; FU ShiJie; YAO JianQuan

    2017-01-01

    High-power terahertz (THz) generation in the frequency range of0.1-10 THz has been a fast-developing research area ever since the beginning of the THz boom two decades ago,enabling new technological breakthroughs in spectroscopy,communication,imaging,etc.By using optical (laser) pumping methods with near-or mid-infrared (IR) lasers,flexible and practical THz sources covering the whole THz range can be realized to overcome the shortage of electronic THz sources and now they are playing important roles in THz science and technology.This paper overviews various optically pumped THz sources,including femtosecond laser based ultrafast broadband THz generation,monochromatic widely tunable THz generation,single-mode on-chip THz source from photomixing,and the traditional powerful THz gas lasers.Full descriptions from basic principles to the latest progress are presented and their advantages and disadvantages are discussed as well.It is expected that this review gives a comprehensive reference to researchers in this area and additionally helps newcomers to quickly gain understanding of optically pumped THz sources.

  13. Sich selbst und den anderen aus einer asymmetrischen Position verstehen – Die Kunst der Unterscheidung

    Directory of Open Access Journals (Sweden)

    Marek Čikel

    2016-12-01

    Full Text Available Sich selbst und den Anderen zu kennen setzt immer eine asymmetrische Position voraus. Die Person ist darauf gestellt, diese Leistung aus einer Position durchzufĂŒhren, die keine klare Orientierung ermöglicht und unsere derzeitigen Dispositionen betrĂ€chtlich ĂŒbersteigt. Dem Menschen wird schließlich immer so viel gezeigt, damit er weiß und sieht, aber nicht so klar, damit er auch versteht. Die Art und Weise, in welcher eine Person mit sich selbst, mit dem Zorn, der Frustration, den Leidenschaften, der Sprache umgeht, vermittelt Informationen ĂŒber individuelle Regungen der Seele, ĂŒber BewĂ€ltigungsmechanismen. Man kann sie fĂŒr eine gewisse Hilfestellung der Sprache selbst halten. Aber das VerstĂ€ndnis dieser Hilfestellung und des Ratschlags nur im VerhĂ€ltnis zu sich selbst wĂ€re zu eng. Wir wollen oder bekommen oft RatschlĂ€ge, die andere betreffen, aber wir mĂŒssen sie „aus sich selbst“ lösen. Und gerade aus sich selbst sollen wir fragen und sprechen. Im Augenblick, wenn diese Tiefe des Sprechens und Hörens erreicht wird, eröffnet sich die Möglichkeit, mit sich selbst und mit dem Anderen zu sein. Es ist jedoch zugleich ein Augenblick des Kampfes, der sich am Hintergrund des Gehörten konstituiert, das am Anfang oft als etwas UnverstĂ€ndliches erscheint oder das durch Vorstellungen und Schmerzen gestört wird. Die Antwort auf diesen Kampf ist die Kunst der Unterscheidung.

  14. Extension of the AUS reactor neutronics system for application to fusion blanket neutronics

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1984-03-01

    The AUS modular code scheme for reactor neutronics computations has been extended to apply to fusion blanket neutronics. A new group cross-section library with 200 neutron groups, 37 photon groups and kerma factor data has been generated from ENDF/B-IV. The library includes neutron resonance subgroup parameters and temperature-dependent data for thermal neutron scattering matrices. The validity of the overall calculation system for fusion applications has been checked by comparison with a number of published conceptual design studies

  15. Nanostrukturierte Filme aus anorganisch-organischen Hybridmaterialien fĂŒr die Photovoltaik

    OpenAIRE

    Perlich, Jan

    2009-01-01

    Es wurden nanostrukturierte dĂŒnne Filme aus kristallinem TiO2 fĂŒr Anwendungen in der Photovoltaik untersucht. Die Herstellung der dĂŒnnen Filme basiert auf einem Hybridansatz. Das ĂŒber eine Sol-Gel-Synthese bereitgestellte anorganische Metalloxid wird durch die Templateigenschaften des eingesetzten organischen Diblockcopolymers strukturiert. Über die Filmaufbringung mittels Schleuderbeschichtung wurden zunĂ€chst Hybridfilme hergestellt, die durch Kalzinierung in kristalline TiO2-Filme mit maßge...

  16. Electronic Commerce - HĂŒrden, Entwicklungspotential, Konsequenzen : Ergebnisse aus der Electronic Commerce Enquete

    OpenAIRE

    MĂŒller, GĂŒnter; Schoder, Detlef

    1999-01-01

    Vorhersagen zu Wachstum und Volumen elektronisch gestĂŒtzten GeschĂ€ftsverkehrs zeichnen ĂŒberwiegend ein sehr positives Zukunftsbild. In krassem Gegensatz dazu stehen Aussagen aus ex post-Analysen des Electronic Commerce zu „harten“ ökonomischen Variablen wie etwa Umsatz- oder Gewinnsteigerung, Kostensenkung und Erhöhung von Marktanteilen. In vielen FĂ€llen bewahrheiten sich euphorische Voraussagen zum Erfolg von Electronic Commerce-AktivitĂ€ten fĂŒr Unternehmen nicht einmal annĂ€hernd. Verlustmeld...

  17. POW3D-Neutron diffusion module of the AUS system. A user's manual

    International Nuclear Information System (INIS)

    Harrington, B.V.; Pollard, J.P.; Barry, J.M.

    1996-11-01

    POW3D is a three-dimensional neutron diffusion module of the AUS modular neutronics code system. It performs eigenvalue, source of feedback-free kinetics calculations. The module includes general criticality search options and extensive editing facilities including perturbation calculations. Output options include flux or reaction rate plot files. The code permits selection from one of a variety of different solution methods (MINI, ICCG or SLOR) for inner iterations with region re balance to enhance convergence. A MINI accelerated Gauss-Siedel method is used for upscatter iterations with group rebalance to enhance a convergence. Chebyshev source extrapolation is applied for outer iterations. A detailed index is included

  18. ZusammenhĂ€nge zwischen Cyberbullying und Bullying – erste Ergebnisse aus einer Selbstberichtsstudie

    OpenAIRE

    Wachs, Sebastian; Wolf, Karsten D.

    2011-01-01

    Wenn Lis (2007) Annahme zutrifft, dass das neue PhĂ€nomen Cyberbullying nichts anderes ist als „alter Wein in neuen SchlĂ€uchen“, dann sind viele Cyberbullies und Cybervictims gleich-zeitig auch Bullies und Victims im realen Leben. Weitere Ziele waren, die PrĂ€valenz von (Cyber-)Bullying zu messen und die Gemeinsamkeiten und Unterschiede beider Formen zu untersuchen. Die Studie wurde als Online-Umfrage nach der CAPI-Methode umgesetzt. Das Sample besteht aus 838 Jugendlichen (von 11-17 Jahren), d...

  19. CHAR and BURNMAC - burnup modules of the AUS neutronics code system

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1986-03-01

    In the AUS neutronics code system, the burnup module CHAR solves the nuclide depletion equations by an analytic technique in a number of spatial zones. CHAR is usually used as one component of a lattice burnup calculation but contains features which also make it suitable for some global burnup calculations. BURNMAC is a simple accounting module based on the assumption that cross sections for a rector zone depend only on irradiation. BURNMAC is used as one component of a global calculation in which burnup is achieved by interpolation in the cross sections produced from a previous lattice calculation

  20. Cyber-Security aus ordnungspolitischer Sicht: VerfĂŒgungsrechte, Wettbewerb und Nudges

    OpenAIRE

    Dold, Malte; Krieger, Tim

    2017-01-01

    Cyber-Security ist aus ökonomischer Sicht vor allem eine Frage fehlgeleiteter Anreize. Wenn Marktakteure nicht die vollen Kosten ihres informationstechnologischen Handelns tragen, fĂŒhrt dies zu ineffizienten MĂ€rkten. Ein Grund fĂŒr die geringen Investitionen in Cyber-Security dĂŒrfte in fehlenden VerfĂŒgungsrechten an den eigenen Daten im Internet liegen. DarĂŒber hinaus mĂŒsste das Wettbewerbsrecht ausgeweitet werden, um eine Machtkonzentration auf Anbieterseite zu verhindern und ein Mindestmaß a...

  1. Supercritical waste oxidation pump investigation

    International Nuclear Information System (INIS)

    Thurston, G.; Garcia, K.

    1993-02-01

    This report investigates the pumping techniques and pumping equipment that would be appropriate for a 5,000 gallon per day supercritical water oxidation waste disposal facility. The pumps must boost water, waste, and additives from atmospheric pressure to approximately 27.6 MPa (4,000 psia). The required flow ranges from 10 gpm to less than 0.1 gpm. For the higher flows, many commercial piston pumps are available. These pumps have packing and check-valves that will require periodic maintenance; probably at 2 to 6 month intervals. Several commercial diaphragm pumps were also discovered that could pump the higher flow rates. Diaphragm pumps have the advantage of not requiring dynamic seals. For the lower flows associated with the waste and additive materials, commercial diaphragm pumps. are available. Difficult to pump materials that are sticky, radioactive, or contain solids, could be injected with an accumulator using an inert gas as the driving mechanism. The information presented in this report serves as a spring board for trade studies and the development of equipment specifications

  2. Experimental Study on Series Operation of Sliding Vane Pump and Centrifugal Pump

    OpenAIRE

    Li, Tao; Zhang, Weiming; Jiang, Ming; Li, Zhengyang

    2013-01-01

    A platform for sliding vane pump and centrifugal pump tests is installed to study the series operation of them under different characteristics of pipeline. Firstly, the sliding vane pump and the centrifugal pump work independently, and the performance is recorded. Then, the two types of pumps are combined together, with the sliding vane pump acting as the feeding pump. Comparison is made between the performance of the independently working pump and the performance of series operation pump. Re...

  3. EDITAR: a module for reaction rate editing and cross-section averaging within the AUS neutronics code system

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1986-03-01

    The EDITAR module of the AUS neutronics code system edits one and two-dimensional flux data pools produced by other AUS modules to form reaction rates for materials and their constituent nuclides, and to average cross sections over space and energy. The module includes a Bsub(L) flux calculation for application to cell leakage. The STATUS data pool of the AUS system is used to enable the 'unsmearing' of fluxes and nuclide editing with minimal user input. The module distinguishes between neutron and photon groups, and printed reaction rates are formed accordingly. Bilinear weighting may be used to obtain material reactivity worths and to average cross sections. Bilinear weighting is at present restricted to diffusion theory leakage estimates made using mesh-average fluxes

  4. AusĂȘncia de expectativa de suporte para o cuidado aos idosos da comunidade

    Directory of Open Access Journals (Sweden)

    DĂ©borah Cristina de Oliveira

    2016-06-01

    Full Text Available RESUMO Objetivo: identificar fatores associados Ă  ausĂȘncia de expectativa de suporte para o cuidado aos idosos da comunidade. MĂ©todo: foram utilizados parte dos dados do estudo multicĂȘntrico "Fragilidade em Idosos Brasileiros", pesquisa quantitativa, epidemiolĂłgica e transversal desenvolvida no perĂ­odo de 2008 a 2009. Foram realizadas anĂĄlises de comparação e regressĂŁo dos dados de 671 idosos. Resultados: a avaliação da expectativa de suporte para o cuidado aos idosos mostrou-se um bom indicador de risco para ausĂȘncia de expectativa de suporte em mulheres, idosos que residiam sozinhos e com percepção ruim da prĂłpria saĂșde. ConclusĂŁo: conclui-se que Ă© preciso refletir sobre o sistema de suporte oferecido aos idosos no Brasil, visto que o perfil destes que estĂŁo em risco Ă© cada vez maior na população. Ressalta-se tambĂ©m a importĂąncia da inserção de mĂ©todos subjetivos para avaliação da percepção dos idosos sobre suporte para o cuidado.

  5. Heat recovery from compressed air in sludge activation plants; Waermerueckgewinnung aus der Druckluft von Belebungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Strunkheide, J.; Eckhardt, R.; Witte, H. [IWB Gemeinnuetziges Inst. Wasser und Boden e.V., Sankt Augustin (Germany)

    2002-07-01

    The Herdorf sewage system is presented as an example of heat recovery from compressed air of the activation stage. Consumption of externally supplied fuel (heating oil) was minimised, and full-scale power generation from sewage gas provided additional income. The key element of the heat recovery system is the air cooler with a matched double-shell heat exchanger. Temperatures and water volumes on the heating water side can be varied in order to ensure optimum heat supply to the air cooler at any time. The heat is used in the internal heating system to heat up the raw sludge in the fermentation process. [German] Die Waermerueckgewinnung aus der Druckluft von Belebungsanlagen kann einen wesentlichen Beitrag zum Waermehaushalt von Klaeranlagen liefern, wie hier am Beispiel der Klaeranlage Herdorf erlaeutert wurde. Hierdurch konnte zum einen der Einsatz von Fremdbrennstoffen (Heizoel) auf ein Minimum reduziert und zum anderen konnten zusaetzliche Ertraege aus der vollstaendigen Verstromung des Faulgases erzielt werden. Kernstueck der Waermerueckgewinnungsanlage bildet der Luftkuehler und der darauf abgestimmte Doppelmantelrohr-Waermeuebertrager. Von wesentlicher Bedeutung ist hierbei, dass auf der Heizkreiswasserseite mit variablen Heizwassermengen und korrespondierenden Temperaturen gefahren werden kann, um zu jedem Zeitpunkt die optimale Waerme durch den Luftkuehler bedarfsorientiert abgreifen zu koennen. Die Waerme dient zur Einspeisung in das Betriebs-Heizungssystem und damit zur Rohschlamm-Aufheizung im Faulungsprozess. (orig.)

  6. Back to nature: Power from biomass; Zurueck zur Natur: Energie aus Biomasse

    Energy Technology Data Exchange (ETDEWEB)

    Beerbaum, S. [Hohenheim Univ. (Germany). Inst. fuer Agrarpolitik und landwirtschaftliche Marktlehre; Kappelmann, K.H. [Fachhochschule Nuertingen (Germany); Haerdtlein, M. [Stuttgart Univ. (Germany). Inst. fuer Energiewirtschaft und Rationelle Energieanwendung; Kaltschmitt, M. [Technische Univ. Muenchen-Weihenstephan (Germany); Ising, M. [Fraunhofer Inst. fuer Umwelt-, Sicherheits-, und Energietechnik, Oberhausen (Germany); Meier, D.; Faix, O. [Institut fuer Holzchemie und chemische Technologie des Holzes, Hamburg (Germany); Gerdes, C. [Hamburg Univ. (Germany). Inst. fuer Makromolekulare und Technische Chemie

    2000-05-01

    Excepting nuclear power, there are just two strategies to reduce global warming, i.e. either by saving energy or by using renewables, supported by public funding and guaranteed rates. The options of solar, wind, and hydroelectric power are limited in our climate and their potential is nearly completely exploited in some regions already. Biomass is an interesting option. Its introduction should be speeded up as it takes about 50 - 60 years for a new technology to be fully accepted. [German] Soll der Treibhauseffekt eingedaemmt werden, ohne in grossem Umfang auf Kernenergie zurueckzugreifen, bleiben nur zwei Moeglichkeiten: Energiesparen und verstaerkter Einsatz regenerativer Energiequellen. Finanzielle Foerderung aus oeffentlichen Mitteln und Garantiepreise bei der Stromerzeugung sollen den Weg gangbar machen. Sonne, Wind und Wasser eignen sich leider hierzulande nur begrenzt, teilweise ist ihr Potenzial schon weitgehend ausgeschoepft. Eine wichtige Ergaenzung des Angebots duerfte deshalb die Biomasse sein. Letztlich ist sie eine Speicherform von Sonnenenergie: Durch Photosynthese erzeugen Pflanzen aus Kohlendioxid und Wasser ihre eigenen Energietraeger, die Kohlenhydrate. Weil beim Verbrennen nur das aufgenommene Kohlendioxid wieder frei wird, zeigt die energetische Nutzung von Biomasse eine weitgehend ausgeglichene Klimabilanz. Doch Eile ist geboten. Die Nutzung von Kohle und Erdoel benoetigte 50 bis 60 Jahre, um sich zu etablieren; Experten halten das fuer einen typischen Zeitraum (den auch die Kernenergie noch nicht durchschritten hat). Sich erneuernde Energiequellen stehen noch am Anfang dieser Einfuehrungsphase. (orig.)

  7. Diode laser pumping

    International Nuclear Information System (INIS)

    Skagerlund, L.E.

    1975-01-01

    A diode laser is pumped or pulsed by a repeated capacitive discharge. A capacitor is periodically charged from a dc voltage source via a transformer, the capacitor being discharged through the diode laser via a controlled switching means after one or more charging periods. During a first interval of each charging period the transformer, while unloaded, stores a specific amount of energy supplied from the dc voltage source. During a subsequent interval of the charging period said specific amount of energy is transmitted from the transformer to the capacitor. The discharging of the capacitor takes place during a first interval of a charging period. (auth)

  8. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topolgies are suggested which allow high erosion without limiter failure

  9. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topologies are suggested which allow high erosion without limiter failure

  10. Improvements relating to electromagnetic pumps

    International Nuclear Information System (INIS)

    Davidson, D.F.

    1975-01-01

    Reference is made to electromagnetic pumps suitable for use in pumping molten Na, and particularly to annular linear induction pumps that may for example be used to pump molten Na at temperatures up to 650 0 in situations where it is not possible to provide cooling. Previous designs of such pumps have employed disk-shaped coils around the outside of the annulus, the coils being energised from a three-phase power supply to produce a travelling radial field. The pump system described obviates the necessity for joints between the coils. It also allows the use of all types of high temperature insultation, simplified manufacture, and enables the windings to be located on the inside of the annulus. Full constructional details are given. (U.K.)

  11. Fast breeder reactor electromagnetic pump

    International Nuclear Information System (INIS)

    Araseki, Hideo; Murakami, Takahiro

    2008-01-01

    Main pumps circulating sodium in the FBR type reactor have been mechanical types, not electromagnetic pumps. Electromagnetic pump of 1-2 m 3 /min has been used as an auxiliary pump. Large sized electromagnetic pumps such as several hundred m 3 /min have not been commercialized due to technical difficulties with electromagnetic instability and pressure pulsations. This article explained electromagnetic and fluid equations and magnetic Reynolds number related with electromagnetic pumps and numerical analysis of instability characteristics and pressure pulsations and then described applications of the results to FBR system. Magnetic Reynolds number must be chosen less than one with appropriate operating frequency and optimum slip of 0.2-0.4. (T. Tanaka)

  12. Mechanical pumping at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1994-12-31

    This new concept consists of a mechanical pump able to run at low temperature (25 K). Since gas density varies inversely with temperature, the pump could deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are reduction of an order of magnitude in size and weight when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. Results obtained at 80 K and 25 K with a Holweck type molecular drag pump of 100 mm diameter and with few stages of a turbomolecular pump running at the same temperatures, are given. This pump would be a solution to allow continuous tritium extraction and minimize the mass inventory for the ITER (International Tokamak Experiment Reactor). 5 figs., 2 tabs., 4 refs.

  13. Centrifugal pumps: fundamentals and classification

    International Nuclear Information System (INIS)

    Solar Manuel, A. M.

    2009-01-01

    Centrifugal pumps are usually employed to impulse water to elevate it, dose it or give it pressure or speed. They can be used with clean water or loaded with high solid concentration and don't work properly with air or another gas flow. There are another less used pumps, coming from volumetric or ram pumps to magnetic ones for specific uses. Centrifugal ones are rotokinetic pumps, like peripherical or lateral channel pumps. They work in a different way that non rotational kinetic ones and static ones. The work approaches their pre definition, selection, installation, operation and maintenance. It also review their morphology, hidromechanic principles and the basic elements pumps are made of. (Author)

  14. Considerations for reference pump curves

    International Nuclear Information System (INIS)

    Stockton, N.B.

    1992-01-01

    This paper examines problems associated with inservice testing (IST) of pumps to assess their hydraulic performance using reference pump curves to establish acceptance criteria. Safety-related pumps at nuclear power plants are tested under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (the Code), Section 11. The Code requires testing pumps at specific reference points of differential pressure or flow rate that can be readily duplicated during subsequent tests. There are many cases where test conditions cannot be duplicated. For some pumps, such as service water or component cooling pumps, the flow rate at any time depends on plant conditions and the arrangement of multiple independent and constantly changing loads. System conditions cannot be controlled to duplicate a specific reference value. In these cases, utilities frequently request to use pump curves for comparison of test data for acceptance. There is no prescribed method for developing a pump reference curve. The methods vary and may yield substantially different results. Some results are conservative when compared to the Code requirements; some are not. The errors associated with different curve testing techniques should be understood and controlled within reasonable bounds. Manufacturer's pump curves, in general, are not sufficiently accurate to use as reference pump curves for IST. Testing using reference curves generated with polynomial least squares fits over limited ranges of pump operation, cubic spline interpolation, or cubic spline least squares fits can provide a measure of pump hydraulic performance that is at least as accurate as the Code required method. Regardless of the test method, error can be reduced by using more accurate instruments, by correcting for systematic errors, by increasing the number of data points, and by taking repetitive measurements at each data point

  15. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  16. Mikrobiologische und biochemische Analyse der Fermentationseigenschaften von Lactobacillus paralimentarius AL28 und Lactobacillus plantarum AL30 in Sauerteigen aus Pseudozerealien

    OpenAIRE

    Vogel, Antje

    2011-01-01

    Pseudozerealien besitzen kein Gluten und sind daher fĂŒr Menschen mit Zöliakie von Bedeutung. Es gibt derzeit keine kommerziell erhĂ€ltlichen Starterkulturen fĂŒr Sauerteige aus Pseudozerealien. In der vorliegenden Arbeit wurden die StĂ€mme L. paralimentarius AL28 und L. plantarum AL30 in ihrer Eignung als Starterkulturen fĂŒr Sauerteige aus Pseudozerealien evaluiert. In den Analysen wurden Amaranth und Buchweizen eingesetzt. Die Teige wurden im Labormaßstab bei 30°C und einer Teigausbeute 200...

  17. Effect of pump limiter throat on pumping efficiency

    International Nuclear Information System (INIS)

    Ghendrih, P.; Grosman, A.; Samain, A.; Capes, H.; Morera, J.P.

    1988-01-01

    The necessary control of plasma edge density has led to the development of pump limiters to achieve this task. On Tore Supra, where a large part of the program is devoted to plasma edge studies, two types of such density control apparatus have been implemented, a set of pump limiters and the pumps associated to the ergodic divertor (magnetically assisted pump limiters). Generally two different kinds of pump limiters can be used, those with a throat which drives the plasma from the open edge plasma (SOL) to the neutralizer plate, and those without or with a very short throat. We are interested here in this aspect of the pump limiter concept, i.e. on the throat effect on neutral density build-up in the vicinity of the pumping plates (and hence on pumping efficieny). The underlying idea of this throat effect can be readily understood; indeed while the neutral capture in pump limiters without throats is only a ballistic effect, on expects the plasma to improve the efficiency of pump-limiters via plasma-neutral-sidewall interactions in the throat. This problem has been studied both numerically and analytically. The paper is divided as follows. In section 2, we describe the basic features of pump-limiters which are modelized by the numerical code Cezanne. Section 3 is devoted to the throat length effect considering in particular the neutral density profile in the throat and the neutral density buil-up as a function of the throat lenght. In section 4, we show that the plugging effect occurs for reasonnable values of throat lengths. An analytical value of the plugging length is discussed and compared to the values obtained numerically

  18. Pump cavitation and inducer design

    International Nuclear Information System (INIS)

    Heslenfeld, M.W.; Hes, M. de

    2002-01-01

    Details of past work on sodium pump development and cavitation studies executed mainly for SNR 300 were reported earlier. Among the requirements for large sodium pumps are long life (200000 hours up to 300000 hours) and small size of impeller and pump, fully meeting the process and design criteria. These criteria are the required 'Q, H, r characteristics' in combination with a low NPSH value and the avoidance of cavitation damage to the pump. The pump designer has to develop a sound hydraulic combination consisting of suction arrangement, impeller design and diffuser. On the other hand the designer is free to choose an optimal pump speed. The pump speed in its turn influences the rotor dynamic pump design and the pump drive. The introduction of the inducer as an integral part of the pump design is based on following advantages: no tip cavitation; (possible) cavitation bubbles move to the open centre due to centrifugal forces on the fluid; the head of the inducer improves the inlet conditions of the impeller. The aim of an inducer is the increase in the suction specific speed (SA value) of a pump whereby the inducer functions as a pressure source improving the impeller inlet conditions. With inducer-impeller combinations values up to SA=15000 are realistic. With the use of an inducer the overall pump sizes can be reduced with Ca. 30%. Pumps commonly available have SA values up to a maximum of ca. 10000. A development programme was executed for SNR 300 in order to reach an increase of the suction specific speed of the impeller from SA 8200 to SA 11000. Further studies to optimize pumps design for the follow up line introduced the 'inducer acting as a pre-impeller' development. This programme was executed in the period 1979-1981. At the FDO premises a scale 1 2.8 inducer impeller combination with a suction specific speed SA=15000 was developed, constructed and tested at the water test rig. This water test rig is equipped with a perspex pipe allowing also visualisation

  19. Mechanical pumping at low temperature

    International Nuclear Information System (INIS)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1995-01-01

    This novel concept consist of a mechanical pump able to run at low temperature (25K). Since gas density varies inversely with temperature, this pump would deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are order of magnitude reduction in size, weight, when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. This pump would be a solution to allow continuously tritium extraction and minimize the mass inventory. (orig.)

  20. Proper Sizing of Circulation Pumps

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; NĂžrgaard, JĂžrgen

    2007-01-01

    The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust, but the r......The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust...

  1. High-vacuum plasma pump

    International Nuclear Information System (INIS)

    Dorodnov, A.M.; Minajchev, V.E.; Miroshkin, S.I.

    1980-01-01

    The action of an electric-arc high-vacuum pump intended for evacuating the volumes in which the operation processes are followed by a high gas evolution is considered. The operation of the pump is based on the principle of controlling the getter feed according to the gas load and effect of plasma sorbtion pumping. The pump performances are given. The starting pressure is about 5 Pa, the limiting residual pressure is about 5x10 -6 Pa, the pumping out rate of nitrogen in the pressure range 5x10 -5 -5x10 -3 Pa accounts for about 4000 l/s, the power consumption comes to 6 kW. Analyzing the results of the test operation of the pump, it has been concluded that its principal advantages are the high starting pressure, controlled getter feed rate and possibility of pumping out the gases which are usually pumped out with difficulty. The operation reliability of the pump is defined mainly by reliable operation of the ignition system of the vacuum arc [ru

  2. Mono pump equipment evaluation report

    International Nuclear Information System (INIS)

    1992-01-01

    A mobile pump has been designed, developed, and tested as part of an effort to increase oil spill response time, improve oil/water recovery efficiency and reduce cleanup and reclamation costs. The pump is mounted on an engine powered track carrier, and can be detached from the carrier and skidded into remote spill sites or transported by helicopter. The pump can safely recover highly volatile flammable substances such as condensate and gasoline, as well as heavy crude oil up to 5000 centipoise viscosity. It can pump up to 30 gal/min at zero head, and up to 1000 feet in a vertical direction. 13 figs

  3. Resonant Tunneling Spin Pump

    Science.gov (United States)

    Ting, David Z.

    2007-01-01

    The resonant tunneling spin pump is a proposed semiconductor device that would generate spin-polarized electron currents. The resonant tunneling spin pump would be a purely electrical device in the sense that it would not contain any magnetic material and would not rely on an applied magnetic field. Also, unlike prior sources of spin-polarized electron currents, the proposed device would not depend on a source of circularly polarized light. The proposed semiconductor electron-spin filters would exploit the Rashba effect, which can induce energy splitting in what would otherwise be degenerate quantum states, caused by a spin-orbit interaction in conjunction with a structural-inversion asymmetry in the presence of interfacial electric fields in a semiconductor heterostructure. The magnitude of the energy split is proportional to the electron wave number. Theoretical studies have suggested the possibility of devices in which electron energy states would be split by the Rashba effect and spin-polarized currents would be extracted by resonant quantum-mechanical tunneling.

  4. Survey of pumps for tritium gas

    International Nuclear Information System (INIS)

    Dowell, T.M.

    1983-05-01

    This report considers many different types of pumps for their possible use in pumping tritium gas in the low, intermediate and high vacuum ranges. No one type of pump is suitable for use over the wide range of pumping pressure required in a typical pumping system. The favoured components for such a system are: bellows pump (low vacuum); orbiting scroll pump (intermediate vacuum); magnetically suspended turbomolecular pump (high vacuum); cryopump (high vacuum). Other pumps which should be considered for possible future development are: mound modified vane pump; SRTI wobble pump; roots pump with canned motor. It is proposed that a study be made of a future tritium pumping system in a Canadian tritium facility, e.g. a tritium laboratory

  5. LMR [liquid metal reactor] centrifugal pump coastdowns

    International Nuclear Information System (INIS)

    Dunn, F.E.; Malloy, D.J.

    1987-01-01

    A centrifugal pump model which describes the interrelationships of the pump discharge flowrate, pump speed, shaft torque and dynamic head has been implemented based upon existing models. Specifically, the pump model is based upon the dimensionless-homologous pump theory of Wylie and Streeter. Given data from a representative pump, homologous theory allows one to predict the transient characteristics of similarly sized pumps. This homologous pump model has been implemented into both the one-dimensional SASSYS-1 systems analysis code and the three-dimensional COMMIX-1A code. Comparisons have been made both against other pump models (CRBR) and actual pump coastdown data (EBR-II and FFTF). Agreement with this homologous pump model has been excellent. Additionally, these comparisons indicate the validity of applying the medium size pump data of Wylie and Streeter to a range of typical LMR centrifugal pumps

  6. Work plan, AP-102 mixer pump removal and pump replacement

    International Nuclear Information System (INIS)

    Jimenez, R.F.

    1994-01-01

    The objective of this work plan is to plan the steps and estimate the costs required to remove the failed AP-102 mixer pump, and to plan and estimate the cost of the necessary design and specification work required to order a new, but modified, mixer pump including the pump and pump pit energy absorbing design. The main hardware required for the removal of the mixer is as follows: a flexible receiver and blast shield; a metal container for the pulled mixer pump; and a trailer and strongback to haul and manipulate the container. Additionally: a gamma scanning device will be needed to detect the radioactivity emanating from the mixer as it is pulled from the tank; a water spray system will be required to remove tank waste from the surface of the mixer as it is pulled from the AP-102 tank; and a lifting yoke to lift the mixer from the pump pit (the SY-101 Mixer Lifting Yoke will be used). A ''green house'' will have to be erected over the AP-102 pump pit and an experienced Hoisting and Rigging crew must be assembled and trained in mixer pump removal methods before the actual removal is undertaken

  7. Diode-pumped laser with improved pumping system

    Science.gov (United States)

    Chang, Jim J.

    2004-03-09

    A laser wherein pump radiation from laser diodes is delivered to a pump chamber and into the lasing medium by quasi-three-dimensional compound parabolic concentrator light channels. The light channels have reflective side walls with a curved surface and reflective end walls with a curved surface. A flow tube between the lasing medium and the light channel has a roughened surface.

  8. Pumps in wearable ultrafiltration devices: pumps in wuf devices.

    Science.gov (United States)

    Armignacco, Paolo; Garzotto, Francesco; Bellini, Corrado; Neri, Mauro; Lorenzin, Anna; Sartori, Marco; Ronco, Claudio

    2015-01-01

    The wearable artificial kidney (WAK) is a device that is supposed to operate like a real kidney, which permits prolonged, frequent, and continuous dialysis treatments for patients with end-stage renal disease (ESRD). Its functioning is mainly related to its pumping system, as well as to its dialysate-generating and alarm/shutoff ones. A pump is defined as a device that moves fluids by mechanical action. In such a context, blood pumps pull blood from the access side of the dialysis catheter and return the blood at the same rate of flow. The main aim of this paper is to review the current literature on blood pumps, describing the way they have been functioning thus far and how they are being engineered, giving details about the most important parameters that define their quality, thus allowing the production of a radar comparative graph, and listing ideal pumps' features. © 2015 S. Karger AG, Basel.

  9. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas NĂžrgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  10. 46 CFR 119.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge pumps. 119.520 Section 119.520 Shipping COAST... Ballast Systems § 119.520 Bilge pumps. (a) Each vessel must be provided with bilge pumps in accordance... have a portable hand bilge pump that must be: (1) Capable of pumping water, but not necessarily...

  11. 46 CFR 154.1135 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pumps. 154.1135 Section 154.1135 Shipping COAST GUARD... Pumps. (a) Water to the water spray system must be supplied by: (1) A pump that is only for the use of the system; (2) A fire pump; or (3) A pump specially approved by the Commandant (CG-522). (b...

  12. 33 CFR 157.126 - Pumps.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Pumps. 157.126 Section 157.126... Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.126 Pumps. (a) Crude oil must be supplied to the COW machines by COW system pumps or cargo pumps. (b) The pumps under paragraph...

  13. High temperature thermoacoustic heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [Energy research Centre of the Netherlands, 1755 ZG Petten (Netherlands)

    2012-06-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. A thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestics and offices energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6% and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  14. Review of magnetohydrodynamic pump applications

    Directory of Open Access Journals (Sweden)

    O.M. Al-Habahbeh

    2016-06-01

    Full Text Available Magneto-hydrodynamic (MHD principle is an important interdisciplinary field. One of the most important applications of this effect is pumping of materials that are hard to pump using conventional pumps. In this work, the progress achieved in this field is surveyed and organized according to the type of application. The literature of the past 27 years is searched for the major developments of MHD applications. MHD seawater thrusters are promising for a variety of applications requiring high flow rates and velocity. MHD molten metal pump is important replacement to conventional pumps because their moving parts cannot stand the molten metal temperature. MHD molten salt pump is used for nuclear reactor coolants due to its no-moving-parts feature. Nanofluid MHD pumping is a promising technology especially for bioapplications. Advantages of MHD include silence due to no-moving-parts propulsion. Much progress has been made, but with MHD pump still not suitable for wider applications, this remains a fertile area for future research.

  15. Direct solar-pumped lasers

    Science.gov (United States)

    Lee, J. H.; Shiu, Y. J.; Weaver, W. R.

    1980-01-01

    The feasibility of direct solar pumping of an iodine photodissociation laser at lambda = 1.315 microns was investigated. Threshold inversion density and effect of elevated temperature (up to 670 K) on the laser output were measured. These results and the concentration of solar radiation required for the solar pumped iodine laser are discussed.

  16. Heat pumping in nanomechanical systems.

    Science.gov (United States)

    Chamon, Claudio; Mucciolo, Eduardo R; Arrachea, Liliana; Capaz, Rodrigo B

    2011-04-01

    We propose using a phonon pumping mechanism to transfer heat from a cold to a hot body using a propagating modulation of the medium connecting the two bodies. This phonon pump can cool nanomechanical systems without the need for active feedback. We compute the lowest temperature that this refrigerator can achieve. © 2011 American Physical Society

  17. Heat pumping in nanomechanical systems

    OpenAIRE

    Chamon, Claudio; Mucciolo, Eduardo R.; Arrachea, Liliana; Capaz, Rodrigo B.

    2010-01-01

    We propose using a phonon pumping mechanism to transfer heat from a cold to a hot body using a propagating modulation of the medium connecting the two bodies. This phonon pump can cool nanomechanical systems without the need for active feedback. We compute the lowest temperature that this refrigerator can achieve.

  18. High Temperature Thermoacoustic Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-07-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. Thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestic and office energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6 % and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  19. Reflection of centrifugal pumps maintenance

    International Nuclear Information System (INIS)

    Mozos Fernandez, V.

    2010-01-01

    The aim of this work is to prove that is not necessary a deep and complex knowledge to manage the centrifugal pumps maintenance. According to the author, only deep but single technical knowledge about causes of breakdowns in the different and simple component parts of the pumps, are required. (Author)

  20. The Plasma Membrane Calcium Pump

    Science.gov (United States)

    Rasmussen, H.

    1983-01-01

    Three aspect of cellular calcium metabolism in animal cells was discussed including the importance of the plasma membrane in calcium homeostasis, experiments dealing with the actual mechanism of the calcium pump, and the function of the pump in relationship to the mitochondria and to the function of calmodulin in the intact cell.

  1. Self pumping magnetic cooling

    International Nuclear Information System (INIS)

    Chaudhary, V; Wang, Z; Ray, A; Ramanujan, R V; Sridhar, I

    2017-01-01

    Efficient thermal management and heat recovery devices are of high technological significance for innovative energy conservation solutions. We describe a study of a self-pumping magnetic cooling device, which does not require external energy input, employing Mn–Zn ferrite nanoparticles suspended in water. The device performance depends strongly on magnetic field strength, nanoparticle content in the fluid and heat load temperature. Cooling (Δ T ) by ∌20 °C and ∌28 °C was achieved by the application of 0.3 T magnetic field when the initial temperature of the heat load was 64 °C and 87 °C, respectively. These experiments results were in good agreement with simulations performed with COMSOL Multiphysics. Our system is a self-regulating device; as the heat load increases, the magnetization of the ferrofluid decreases; leading to an increase in the fluid velocity and consequently, faster heat transfer from the heat source to the heat sink. (letter)

  2. Electric Turbo Pump

    Science.gov (United States)

    Steckler, Jessica

    2017-01-01

    NASA is working in junction with another company on the Electric Turbo Pump. Analysis of the impeller, including the blades, volute housing, and associated components, will take place in ANSYS. Contours of the deformed and stress were recorded to assess the parts. Campbell diagrams will be considered as mentioned to find the operating regions of the impeller and volute housing, more specifically what speed is ideal to ensure that the impeller does not begin to vibrate at a frequency that will break it. More than one material will be examined as per request by the designer to determine which material is more cost efficient, easy to machine, and can withstand the stress values that will be placed on it.

  3. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  4. Dual source heat pump

    Science.gov (United States)

    Ecker, Amir L.; Pietsch, Joseph A.

    1982-01-01

    What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating the fluid in heat exchange relationship with a refrigerant fluid; at least two refrigerant heat exchangers, one for effecting heat exchange with the fluid and a second for effecting heat exchange between refrigerant and a heat exchange fluid and the ambient air; a compressor for efficiently compressing the refrigerant; at least one throttling valve for throttling liquid refrigerant; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and direction of flow of the refrigerant therethrough for selecting a particular mode of operation. The heat exchange fluid provides energy for defrosting the second heat exchanger when operating in the air source mode and also provides a alternate source of heat.

  5. High temperature industrial heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Berghmans, J. (Louvain Univ., Heverlee (Belgium). Inst. Mechanica)

    1990-01-01

    The present report intends to describe the state of the art of high temperature industrial heat pumps. A description is given of present systems on the market. In addition the research and development efforts on this subject are described. Compression (open as well as closed cycle) systems, as well as absorption heat pumps (including transformers), are considered. This state of the art description is based upon literature studies performed by a team of researchers from the Katholieke Universiteit Leuven, Belgium. The research team also analysed the economics of heat pumps of different types under the present economic conditions. The heat pumps are compared with conventional heating systems. This analysis was performed in order to evaluate the present condition of the heat pump in the European industry.

  6. Briefe aus dem Morgenland - Otto Friedrich von Richters Forschungsreise in den Jahren 1814-1816 / Vladimir Sazonov

    Index Scriptorium Estoniae

    Sazonov, Vladimir, 1979-

    2013-01-01

    Arvustus: Briefe aus dem Morgenland - Otto Friedrich von Richters Forschungsreise in den Jahren 1814-1816, hrsg. von Indrek JĂŒrjo, Sergei Stadnikov, Hamburger BeitrĂ€ge zur Geschichte des östlichen Europa, Bd. 20. Hamburg: Verlag Dr. Kovač 2013, 313 lk.

  7. High performance brake discs made of fiber reinforced ceramics; Hochleistungsbremsscheiben aus Faserverbundkeramik

    Energy Technology Data Exchange (ETDEWEB)

    Rosenloecher, J.; Deinzer, G.; Waninger, R.; Muenchhoff, J. [AUDI AG, 85045 Ingolstadt (Germany)

    2007-11-15

    The Audi AG is one of the worldwide leading car manufacturers of the premium class. One of the main aims of the technical development department at Audi is the use of novel and innovative materials. The Audi AG has intensively worked on the development and introduction of ceramic brake discs for several car types. These brake discs are made of a short carbon fiber reinforced silicon carbide ceramic, a so called CMC-material (ceramic matrix composite). This material is produced in a very complex process by silicon melt infiltration of carbon preforms. The advantages of these innovative and powerful brake discs out of C/SiC-ceramic are the low weight and thus the reduction of the unsprung rotating masses, the low wear rate during completed service life, the temperature and fading stability and the corrosion resistance. The complete braking system and its periphery had to be reengineered and adjusted because of the specific material properties. (Abstract Copyright [2007], Wiley Periodicals, Inc.) [German] Die Audi AG ist einer der weltweit fuehrenden Automobilhersteller der Premiumklasse. Eines der Hauptziele der Technischen Entwicklung bei Audi ist der Einsatz neuartiger und innovativer Werkstoffe. Daher bietet die Audi AG nach intensiver Entwicklung und Erprobung fuer mehrere Fahrzeugmodelle Keramikbremsscheiben an. Diese Bremsscheiben bestehen aus einer kohlenstoffkurzfaserverstaerkten Siliziumkarbidkeramik, einem sog. CMC-Werkstoff. Dieser Werkstoff wird in einem aufwendigen Verfahren ueber die Schmelzinfiltration von Kohlenstoff-Preformen mit Silizium hergestellt. Die Vorteile dieser innovativen und leistungsfaehigen Bremsscheiben aus C/SiC-Keramik sind das geringe Gewicht und dadurch die Reduzierung der ungefederten rotierenden Massen, der geringe Verschleiss ueber Betriebsdauer, die Temperatur- und Fadingstabilitaet und die Korrosionsbestaendigkeit. Aufgrund der materialspezifischen Eigenschaften wurde das gesamte Bremssystem ueberarbeitet und die

  8. Ein Versuch, NaturverhÀltnisse aus feministischer Sicht zu interpretieren

    Directory of Open Access Journals (Sweden)

    Helga Purgand

    2002-07-01

    Full Text Available Mit dem vorliegenden Sammelband GeschlechterverhĂ€ltnisse – NaturverhĂ€ltnisse wird nach dem innovativen Beitrag der feministischen Debatte fĂŒr umweltsoziologisches Denken gefragt und nach Überschneidungen, Grenzen und ZwischenrĂ€umen zwischen „Geschlecht“ und „Natur“ gesucht. In ihm wird der lobenswerte Versuch unternommen, einen Zusammenhang zwischen Geschlechter- und NaturverhĂ€ltnissen herzustellen „die in der Umweltsoziologie bislang stark vernachlĂ€ssigte feministische Diskussion und Geschlechterforschung einzubeziehen und als genderbezogene Perspektive zu etablieren“. (S. 9 Das Buch enthĂ€lt BeitrĂ€ge von 15 Autorinnen, die unterschiedliche Natur- und GeschlechtsverhĂ€ltnisse facettenreich, ĂŒberwiegend kreativ und theoretisch anspruchsvoll betrachten. Das Buch enthĂ€lt ZugĂ€nge aus der allgemeinen Soziologie, den Sprach- und Kulturwissenschaften, aus politik- und naturwissenschaftlichen ZusammenhĂ€ngen. Den ausdrĂŒcklich formulierten Anspruch, von multi- zu einer inter-disziplinĂ€ren Durchdringung zu gelangen, erfĂŒllt es nur in AnsĂ€tzen (besonders mit der Einleitung und den theoretischen Problemexplikationen. Das zustande gekommene „Nach-, Zusammen- und Querdenken“ ĂŒber Begriffe, Theorien und neuere ForschungsansĂ€tze (von Foucault ĂŒber Butler bis zu Donna Haraway belegt die Notwendigkeit, die naturwissenschaftlichen Annahmen „immanent zu dekonstruieren“. Sehr aufschlussreich sind in diesem Zusammenhang die BeitrĂ€ge von Irmgard Schultz, Elvira Scheich, aber auch von Mary Mellor und besonders von Paula-Irene Villa, die interessante und kreative Gedanken zur KlĂ€rung des VerhĂ€ltnisses von Natur, Kultur und Geschlecht anbieten. Deutlich wurde, dass weiterhin ein kontroverses Ringen um angemessene konzeptionelle Fassungen von Geschlechts- und NaturverhĂ€ltnissen und die Integration von Gender als zentraler analytischer Querschnitts-Kategorie nötig sind. Insgesamt ist dem Buch ist eine schnelle Verbreitung und

  9. Was ist ungerecht? Diskriminierungsebenen aus multiplen Blickwinkeln What is Unjust? Levels of Discrimination from Multiple Perspectives

    Directory of Open Access Journals (Sweden)

    Christoph Sorge

    2008-07-01

    Full Text Available Aus einer interdisziplinĂ€ren Kolloquiumsreihe im Wintersemester 2004/2005 des Cornelia Goethe Centrums fĂŒr Frauenstudien und die Erforschung der GeschlechterverhĂ€ltnisse (CGC ist eine Aufsatzsammlung mit acht BeitrĂ€gen entstanden, welche sich mit frauenspezifischen Unrechtserfahrungen auseinandersetzen. Der Facettenreichtum der Aufsatzthemen entspricht dem im Titelkompositum „Unrechtserfahrungen“ ausgedrĂŒckten SpannungsverhĂ€ltnis: Zum einen wird anhand von konkret erlebten Einzelschicksalen und von Darstellungen in der Literatur die Erfahrung von Ungerechtigkeit und Unrecht problematisiert. Zum anderen wird die rechtliche Begrifflichkeit genauer untersucht. Die Autorinnen kommen aus den Bereichen Philologie, Rechts- und Geschichtswissenschaft. Entsprechend bietet der Band eine vielfĂ€ltige und insgesamt ergiebige Gesamtschau auf die Unrechtserfahrungen von Frauen in Vergangenheit und Gegenwart.This collected volume of eight essays tackles the experience of injustice specific to women. It was born out of an interdisciplinary colloquium during the winter semester of 2004/2005 at the Cornelia Goethe Center for Women’s Studies and the Study of Gender Relations (CGC. The richly varied themes of the essays correspond to the tension expressed in the composite word in the title “unjust-experience”: For one, the volume problematizes the experience of inequality and injustice through individual concrete experience and through literary presentations. In addition, it examines legal terminology in detail. The authors come from the wide-ranging areas of philology, law, and history. Accordingly, the volume offers a diverse and altogether rich overview of women’s experiences of injustice in the past and the present.

  10. Pumping characteristics of sputter ion pump (SIP) and titanium sublimation pump (TSP) combination

    International Nuclear Information System (INIS)

    Ratnakala, K.C.; Patel, R.J.; Bhavsar, S.T.; Pandiyar, M.L.; Ramamurthi, S.S.

    1995-01-01

    For achieving hydrocarbon free, clean ultra high vacuum, SIP-TSP combination is one of the ideal choice for pumping. For the SRS facility in Centre for Advanced Technology (CAT), we are utilising this combination, enmass. For this purpose, two modules of these combination set-ups are assembled, one with the TSP as an integral part of SIP and the other, with TSP as a separate pump mounted on the top of SIP. The pump bodies were vacuum degassed at 700 degC at 10 -5 mbar for 3 hrs. An ultimate vacuum of 3 x 10 -11 mbar was achieved, after a bake-out at 250 degC for 4 hrs, followed by continuous SIP pumping for 48 hrs, with two TSP flashing at approximately 10 hrs interval. The pump-down patterns as well as the pressure-rise patterns are studied. (author). 2 refs., 5 figs

  11. Design of liquid lithium pumps for FMIT

    International Nuclear Information System (INIS)

    Adkins, H.E.

    1983-01-01

    In the Fusion Materials Irradiation Test (FMIT) facility, a jet of liquid lithium is bombarded by accelerated deuterons to generate high energy neutrons for materials testing. The lithium system will include two electromagnetic pumps, a 750 gpm main pump and a 10 gpm auxiliary pump. The larger pump was designed and built in 1982, following extensive testing of a similar pump in the Experimental Lithium System. Design of the auxiliary pump has been completed, but fabrication has not started. This paper discusses the design considerations leading to selection of the Annular Linear Induction Pump (ALIP) concept for these applications. Design parameters, fabrication procedures, and results of pump testing are also reviewed

  12. Peristaltic pumps for waste disposal

    International Nuclear Information System (INIS)

    Griffith, G.W.

    1992-09-01

    Laboratory robots are capable of generating large volumes of hazardous liquid wastes when they are used to perform chemical analyses of metal finishing solutions. A robot at Allied-Signal Inc., Kansas City Division, generates 30 gallons of acid waste each month. This waste contains mineral acids, heavy metals, metal fluorides, and other materials. The waste must be contained in special drums that are closed to the atmosphere. The initial disposal method was to have the robot pour the waste into a collecting funnel, which contained a liquid-sensing valve to admit the waste into the drum. Spills were inevitable, splashing occurred, and the special valve often didn't work well. The device also occupied a large amount of premium bench space. Peristaltic pumps are made to handle hazardous liquids quickly and efficiently. A variable-speed pump, equipped with a quick-loading pump head, was mounted below the robot bench near the waste barrel. The pump inlet tube was mounted above the bench within easy reach of the robot, while the outlet tube was connected directly to the barrel. During operation, the robot brings the waste liquid up to the pump inlet tube and activates the pump. When the waste has been removed, the pump stops. The procedure is quick, simple, inexpensive, safe, and reliable

  13. Magnetohydrodynamic generator and pump system

    International Nuclear Information System (INIS)

    Birzvalk, Yu.A.; Karasev, B.G.; Lavrentyev, I.V.; Semikov, G.T.

    1983-01-01

    The MHD generator-pump system, or MHD coupling, is designed to pump liquid-metal coolant in the primary circuit of a fast reactor. It contains a number of generator and pump channels placed one after another and forming a single electrical circuit, but hydraulically connected parallel to the second and first circuits of the reactor. All the generator and pump channels are located in a magnetic field created by the magnetic system with an excitation winding that is fed by a regulated direct current. In 500 to 2000 MW reactors, the flow rate of the coolant in each loop of the primary circuit is 3 to 6 m 3 /s and the hydraulic power is 2 to 4 MW. This paper examines the primary characteristics of an MHD generator-pump system with various dimensions and number of channels, wall thicknesses, coolant flow rates, and magnetic fields. It is shown that its efficiency may reach 60 to 70%. The operating principle of the MHD generator-pump system is explained in the referenced patent and involves the transfer of hydraulic power from generator channels to pump channels using a magnetic field and electrical circuit common to both channels. Variations of this system may be analyzed using an equivalent circuit. 7 refs., 5 figs

  14. Electrostatic coupling of ion pumps.

    Science.gov (United States)

    Nieto-Frausto, J; LĂŒger, P; Apell, H J

    1992-01-01

    In this paper the electrostatic interactions between membrane-embedded ion-pumps and their consequences for the kinetics of pump-mediated transport processes have been examined. We show that the time course of an intrinsically monomolecular transport reaction can become distinctly nonexponential, if the reaction is associated with charge translocation and takes place in an aggregate of pump molecules. First we consider the electrostatic coupling of a single dimer of ion-pumps embedded in the membrane. Then we apply the treatment to the kinetic analysis of light-driven proton transport by bacteriorhodopsin which forms two-dimensional hexagonal lattices. Finally, for the case of nonordered molecules, we also consider a model in which the pumps are randomly distributed over the nodes of a lattice. Here the average distance is equal to that deduced experimentally and the elemental size of the lattice is the effective diameter of one single pump. This latter model is applied to an aggregate of membrane-embedded Na, K- and Ca-pumps. In all these cases the electrostatic potential considered is the exact solution calculated from the method of electrical images for a plane membrane of finite thickness immersed in an infinite aqueous solution environment. The distributions of charges (ions or charged binding sites) are considered homogeneous or discrete in the membrane and/or in the external solution. In the case of discrete distributions we compare the results from a mean field approximation and a stochastic simulation.

  15. The yeast plasma membrane ATP binding cassette (ABC) transporter Aus1: purification, characterization, and the effect of lipids on its activity.

    Science.gov (United States)

    Marek, Magdalena; Milles, Sigrid; Schreiber, Gabriele; Daleke, David L; Dittmar, Gunnar; Herrmann, Andreas; MĂŒller, Peter; Pomorski, Thomas GĂŒnther

    2011-06-17

    The ATP binding cassette (ABC) transporter Aus1 is expressed under anaerobic growth conditions at the plasma membrane of the yeast Saccharomyces cerevisiae and is required for sterol uptake. These observations suggest that Aus1 promotes the translocation of sterols across membranes, but the precise transport mechanism has yet to be identified. In this study, an extraction and purification procedure was developed to characterize the Aus1 transporter. The detergent-solubilized protein was able to bind and hydrolyze ATP. Mutagenesis of the conserved lysine to methionine in the Walker A motif abolished ATP hydrolysis. Likewise, ATP hydrolysis was inhibited by classical inhibitors of ABC transporters. Upon reconstitution into proteoliposomes, the ATPase activity of Aus1 was specifically stimulated by phosphatidylserine (PS) in a stereoselective manner. We also found that Aus1-dependent sterol uptake, but not Aus1 expression and trafficking to the plasma membrane, was affected by changes in cellular PS levels. These results suggest a direct interaction between Aus1 and PS that is critical for the activity of the transporter.

  16. Analysis of mercury diffusion pumps

    International Nuclear Information System (INIS)

    Dunn, K.A.

    1991-01-01

    Several mercury diffusion pump stages in the Tritium Purification process at the Savannah River Site (SRS) have been removed from service for scheduled preventive maintenance. These stages have been examined to determine if failure has occurred. Evidence of fatigue around the flange portion of the pump has been seen. In addition, erosion and cavitation inside the throat of the venturi tube and corrosion on the other surface of the venturi tube has been observed. Several measures are being examined in an attempt to improve the performance of these pumps. These measures, as well as the noted observations, are described. 4 refs

  17. TFTR ultrahigh-vacuum pumping system incorporating mercury diffusion pumps

    International Nuclear Information System (INIS)

    Sink, D.A.; Sniderman, M.

    1976-06-01

    The TFTR vacuum vessel will have a system of four 61 cm diameter mercury diffusion pumps to provide a base pressure in the 10 -8 to 10 -9 Torr range as well as a low impurity level within the vessel. The system, called the Torus Vacuum Pumping System (TVPS), will be employed with the aid of an occasional 250 0 C bakeout in situ as well as periodic applications of aggressive discharge cleaning. The TVPS is an ultrahigh-vacuum (UHV) system using no elastomers as well as being a closed system with respect to tritium or any tritiated gases. The backing system employing approximately 75 all-metal isolation valves is designed with the features of redundancy and flexibility employed in a variety of ways to meet the fundamental requirements and functions enumerated for the TVPS. Since the design, is one which is a modification of the conceptual design of the TVPS, those features which have changed are discussed. Calculations are presented for the major performance parameters anticipated for the TVPS and include conductances, effective pumping speeds, base pressures, operating parameters, getter pump parameters, and calculations of time constants associated with leak checking. Modifications in the vacuum pumping system for the guard regions on the twelve bellows sections are presented so that it is compatible with the main TVPS. The bellows pumping system consists of a mechanical pump unit, a zirconium aluminum getter pump unit and a residual gas analyzer. The control and management of the TVPS is described with particular attention given to providing both manual and automatic control at a local station and at the TFTR Central Control. Such operations as testing, maintenance, leak checking, startup, bakeout, and various other operations are considered in some detail. Various aspects related to normal pulsing, discharge cleaning, non-tritium operations and tritium operations are also taken into consideration. A cost estimate is presented

  18. Test of a cryogenic helium pump

    International Nuclear Information System (INIS)

    Lue, J.W.; Miller, J.R.; Walstrom, P.L.; Herz, W.

    1981-01-01

    The design of a cryogenic helium pump for circulating liquid helium in a magnet and the design of a test loop for measuring the pump performance in terms of mass flow vs pump head at various pump speeds are described. A commercial cryogenic helium pump was tested successfully. Despite flaws in the demountable connections, the piston pump itself has performed satisfactorily. A helium pump of this type is suitable for the use of flowing supercritical helium through Internally Cooled Superconductor (ICS) magnets. It has pumped supercritical helium up to 7.5 atm with a pump head up to 2.8 atm. The maximum mass flow rate obtained was about 16 g/s. Performance of the pump was degraded at lower pumping speeds

  19. Fluidic pumping system

    International Nuclear Information System (INIS)

    Wilson, P.D.

    1995-01-01

    A fluidic pumping system comprises two charge vessels which communicate with a liquid inlet and a liquid outlet through a fluidic bridge rectifier. A pressurising and depressurising arrangement for alternately pressurising and depressurising the charge vessels comprises a chamber containing a piston and being in communication with the charge vessels. Drive means not mechanically connected to the piston are provided for causing reciprocatory movement of the piston. Movement of the piston in one direction causes pressurisation of one charge vessel to discharge a liquid therefrom through the liquid outlet. Simultaneously, the other charge vessel is depressurised to draw liquid from the liquid inlet into the depressurised charge vessel. Preferably, the drive means for the piston comprises an external solenoid winding at each end of a horizontally arranged chamber. Alternatively, the chamber may be vertically disposed with an external solenoid winding at the upper end of the chamber to effect upward movement of the piston, the piston then falling under gravity upon de-energisation of the winding. (UK)

  20. Exchangers man the pumps

    Science.gov (United States)

    Barkla, Bronwyn J; Hirschi, Kendal D

    2008-01-01

    Tonoplast-localised proton-coupled Ca2+ transporters encoded by cation/H+ exchanger (CAX) genes play a critical role in sequestering Ca2+ into the vacuole. These transporters may function in coordination with Ca2+ release channels, to shape stimulus-induced cytosolic Ca2+ elevations. Recent analysis of Arabidopsis CAX knockout mutants, particularly cax1 and cax3, identified a variety of phenotypes including sensitivity to abiotic stresses, which indicated that these transporters might play a role in mediating the plant's stress response. A common feature of these mutants was the perturbation of H+-ATPase activity at both the tonoplast and the plasma membrane, suggesting a tight interplay between the Ca2+/H+ exchangers and H+ pumps. We speculate that indirect regulation of proton flux by the exchangers may be as important as the direct regulation of Ca2+ flux. These results suggest cautious interpretation of mutant Ca2+/H+ exchanger phenotypes that may be due to either perturbed Ca2+ or H+ transport. PMID:19841670

  1. Reactor coolant purification system circulation pumps (CUW pumps)

    International Nuclear Information System (INIS)

    Tsutsui, Toshiaki

    1979-01-01

    Coolant purification equipments for BWRs have been improved, and the high pressure purifying system has become the main type. The quantity of purifying treatment also changed to 2% of the flow rate of reactor feed water. As for the circulation pumps, canned motor pumps are adopted recently, and the improvements of reliability and safety are attempted. The impurities carried in by reactor feed water and the corrosion products generated in reactors and auxiliary equipments are activated by neutron irradiation or affect heat transfer adversely, adhering to fuel claddings are core structures. Therefore, a part of reactor coolant is led to the purification equipments, and returned to reactors after the impurities are eliminated perfectly. At the time of starting and stopping reactors, excess reactor water and the contaminated water from reactors are transferred to main condenser hot wells or waste treatment systems. Thus the prescribed water quality is maintained. The operational modes of and the requirements for the CUW pumps, the construction and the features of the canned motor type CUW pumps are explained. Recently, a pump operated for 11 months without any maintenance has been disassembled and inspected, but the wear of bearings has not been observed, and the high reliability of the pump has been proved. (Kako, I.)

  2. Pump failure leads to alternative vertical pump condition monitoring technique

    International Nuclear Information System (INIS)

    DeVilliers, Adriaan; Glandon, Kevin

    2011-01-01

    Condition monitoring and detecting early signs of potential failure mechanisms present particular problems in vertical pumps. Most often, the majority of the pump assembly is not readily accessible for visual or audible inspection or conventional vibration monitoring techniques using accelerometers and/or proximity sensors. The root cause failure analysis of a 2-stage vertical centrifugal service-water pump at a nuclear power generating facility in the USA is presented, highlighting this long standing challenge in condition monitoring of vertical pumps. This paper will summarize the major findings of the root cause analysis (RCA), highlight the limitations of traditional monitoring techniques, and present an expanded application of motor current monitoring as a means to gain insight into the mechanical performance and condition of a pump. The 'real-world' example of failure, monitoring and correlation of the monitoring technique to a detailed pump disassembly inspection is also presented. This paper will explain some of the reasons behind well known design principles requiring natural frequency separation from known forcing frequencies, as well as explore an unexpected submerged brittle fracture failure mechanism, and how such issues may be avoided. (author)

  3. Optimisation of pollutant separation and tenside recovery from water/tenside/pollutant mixtures; Optimierung der Schadstoffabtrennung sowie der Rueckgewinnung von Tensiden aus Wasser-Tensid-Schadstoff Mischungen

    Energy Technology Data Exchange (ETDEWEB)

    Memminger, B.

    2001-01-01

    Hydraulic in-situ remediation technologies have recently become more and more important for removing underground contamination especially in urban districts. To enhance the traditional pump-and-treat, substances such as surfactants can be used which not only dissolve but also mobilize the contaminants. For this method to be cost effective, an optimized waste water treatment is essential. On the one hand the contaminants are to be removed from the extracted ground water and on the other hand the surfactants are to be recycled for re-use in the remediation procedure. So far adsorption of contaminants on activated carbon has been applied to reach this goals. In the frame of this diploma thesis however, more efficient and more economical alternatives to the adsorption method were to be investigated. For this, three different separating techniques to treat water-surfactant-contaminant mixtures containing polycyclic aromatic hydrocarbons (PAH) as model substances were examined: a membrane technique by using an entrainer on the permeate side, the so called pertraction, the solvent extraction with petroleum ether as a solvent and the adsorption with other adsorbents. (orig.) [German] Hydraulische in-situ Sanierungsverfahren erfahren derzeit im Rahmen der Altlastenbearbeitung eine zunehmende Bedeutung zur Beseitigung von Untergrundkontaminationen, vor allem in innerstaedtischen Bereichen. Um die traditionelle 'pump and treat'-Methode zu optimieren, koennen Hilfsstoffe wie Loesungsvermittler, z.B. Tenside, eingesetzt werden, die eine sowohl solubilisierende als auch mobilisierende Wirkung auf die Schadstoffe haben. Um dieses Verfahren kosteneffektiv zu gestalten, ist eine optimierte Abwasseraufbereitung gefordert. Dabei sind zum einen die Schadstoffe aus dem extrahierten Grundwasser abzutrennen und zum anderen die Tenside fuer das Verfahren zurueckzugewinnen. Zum bisher dafuer angewandten Adsorptionsverfahren unter Einsatz von Aktivkohle sollten im Rahmen dieser

  4. „NS-Raubgut aus zweiter Hand“ - Provenienzrecherchen in der Bibliothek des IGdJ

    Directory of Open Access Journals (Sweden)

    Jörn Kreuzer

    2014-12-01

    Full Text Available Das Institut fĂŒr die Geschichte der deutschen Juden in Hamburg fĂŒhrt im Rahmen des Projekts "NS-Raubgut in der Bibliothek des IGdJ" umfangreiche Recherchen in seinen BuchbestĂ€nden durch. Die Untersuchung fĂŒgt sich in die Reihe von Forschungsvorhaben, die in der Folge der "Washingtoner Konferenz ĂŒber Vermögenswerte aus der Zeit des Holocaust" (1998 und der ein Jahr spĂ€ter verabschiedeten "ErklĂ€rung der Bundesregierung, der LĂ€nder und der kommunalen SpitzenverbĂ€nde zur Auffindung und zur RĂŒckgabe NS-verfolgungsbedingt entzogenen Kulturgutes, insbesondere aus jĂŒdischem Besitz" in diversen deutschen Bibliotheken, Museen, Archiven und anderen kulturellen Einrichtungen durchgefĂŒhrt werden. Zurzeit befinden sich in der Bibliothek des IGdJ rund 50.000 BĂ€nde. Im Grunde ist bei allen Werken, die vor 1945 erschienen sind, eine Provenienz aus NS-Raub- bzw. NS-BeutegutbestĂ€nden möglich. Eine systematische Erfassung und Bearbeitung dieses rund 6.000 bis 9.000 BĂ€nde umfassenden Bestandes ist bislang nicht erfolgt. Da die Institutsbibliothek als jĂŒdische Sammlung konzipiert und aufgebaut wurde, verstĂ€rkt sich diese Vermutung. Weil das Institut erst 1966 gegrĂŒndet wurde, handelt es sich wahrscheinlich um "NS-Raubgut aus zweiter Hand“. Eine weitere Aufgabenstellung ergibt sich aus der Tatsache, dass in den Anfangsjahren der Bibliothek keine Zugangsjournale gefĂŒhrt wurden. Somit können in vielen FĂ€llen nur die BĂŒcher selbst Hinweise auf ihre Herkunft geben, weshalb als erste Maßnahme die eingehende Buchautopsie anhand des Zettelkatalogs durchgefĂŒhrt wird. Der systematischen Suche nach NS-verfolgungsbedingt entzogenem Kulturgut folgt die Dokumentation und Bekanntgabe der Ergebnisse mit dem Ziel der Restitution an die Vorbesitzer oder deren Erben. In einem Werkstattbericht werden erste Ergebnisse vorgestellt. The Institute of the History of the German Jews (Institut fĂŒr die Geschichte der deutschenJuden, IGdJ is currently conducting a

  5. Magnetic heat pump flow director

    Science.gov (United States)

    Howard, Frank S. (Inventor)

    1995-01-01

    A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

  6. Heat pumps at the maltings

    Energy Technology Data Exchange (ETDEWEB)

    1987-11-01

    Heat pumps have halved the energy costs of producing finished malt at two of the country's maltsters. The fuel-fired kilning processes described are now performed by heat pumps with considerable energy and production benefits at the maltings of J.P. Simpson and Co. (Alnwick) Ltd, in Tivetshall St Margaret, Norfolk, and of Munton and Fison Plc of Stowmarket, Suffolk. The heat pump system installed at the Station Malting of J.P. Simpson was devised by the Electricity Council Research Centre at Capenhurst near Chester. Energy cost benefits of Pound 6,000 a month are being realised at Simpsons, but there is the added benefit that the system has been designed to provide conditioned air to the germination cycle to ensure that the correct temperature is maintained throughout the year. At the Cedars factory of Munton and Fison, heat pumps were used on a trial basis for plant micropropagation and for a fish farming unit.

  7. ENERGY STAR Certified Pool Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.1 ENERGY STAR Program Requirements for Pool Pumps that are effective as of February 15,...

  8. Feed pumps for a NPP

    International Nuclear Information System (INIS)

    Rzhebaev, Eh.E.; Zhukov, V.M.; Evtushenko, A.A.

    1977-01-01

    Given is a brief description of results of designing and testing the PE850-65 and SPE1650-75 pilot feed pumps for 440 MWe pressurized water reactors and for 1000 MWe boiling water reactors. Described is a bench-mark facility for the SPE1650-75 pump with full-scale parameters. The adjustment results of the preconnected axial wheel of the 1PE1650-75 pump during the service life tests of a pilot pump have been given. Practical results on new methods of the preconnected axial wheel protection have been obtained. The design criteria developed provide for the long life time within the proven range of circular velocities. Confirmed is a possibility of carrying out advanced tests for estimating the cavitation destruction intensity using the vibration due to cavitation

  9. Balanced pressure gerotor fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Raney, Michael Raymond; Maier, Eugen

    2004-08-03

    A gerotor pump for pressurizing gasoline fuel is capable of developing pressures up to 2.0 MPa with good mechanical and volumetric efficiency and satisfying the durability requirements for an automotive fuel pump. The pump has been designed with optimized clearances and by including features that promote the formation of lubricating films of pressurized fuel. Features of the improved pump include the use of a shadow port in the side plate opposite the outlet port to promote balancing of high fuel pressures on the opposite sides of the rotors. Inner and outer rotors have predetermined side clearances with the clearances of the outer rotor being greater than those of the inner rotor in order to promote fuel pressure balance on the sides of the outer rotor. Support of the inner rotor and a drive shaft on a single bushing with bearing sleeves maintains concentricity. Additional features are disclosed.

  10. Heat Pumps in Subarctic Areas

    DEFF Research Database (Denmark)

    Atlason, Reynir Smari; Oddsson, Gudmundur Valur; Unnthorsson, Runar

    2017-01-01

    Geothermal heat pumps use the temperature difference between inside and outside areas to modify a refrigerant, either for heating or cooling. Doing so can lower the need for external heating energy for a household to some extent. The eventual impact depends on various factors, such as the external...... source for heating or cooling and the temperature difference. The use of geothermal heat pumps, and eventual benefits has not been studied in the context of frigid areas, such as in Iceland. In Iceland, only remote areas do not have access to district heating from geothermal energy where households may...... therefor benefit from using geothermal heat pumps. It is the intent of this study to explore the observed benefits of using geothermal heat pumps in Iceland, both financially and energetically. This study further elaborates on incentives provided by the Icelandic government. Real data was gathered from...

  11. Transverse pumped laser amplifier architecture

    Science.gov (United States)

    Bayramian, Andrew James; Manes, Kenneth; Deri, Robert; Erlandson, Al; Caird, John; Spaeth, Mary

    2013-07-09

    An optical gain architecture includes a pump source and a pump aperture. The architecture also includes a gain region including a gain element operable to amplify light at a laser wavelength. The gain region is characterized by a first side intersecting an optical path, a second side opposing the first side, a third side adjacent the first and second sides, and a fourth side opposing the third side. The architecture further includes a dichroic section disposed between the pump aperture and the first side of the gain region. The dichroic section is characterized by low reflectance at a pump wavelength and high reflectance at the laser wavelength. The architecture additionally includes a first cladding section proximate to the third side of the gain region and a second cladding section proximate to the fourth side of the gain region.

  12. Method for controlling powertrain pumps

    Science.gov (United States)

    Sime, Karl Andrew; Spohn, Brian L; Demirovic, Besim; Martini, Ryan D; Miller, Jean Marie

    2013-10-22

    A method of controlling a pump supplying a fluid to a transmission includes sensing a requested power and an excess power for a powertrain. The requested power substantially meets the needs of the powertrain, while the excess power is not part of the requested power. The method includes sensing a triggering condition in response to the ability to convert the excess power into heat in the transmission, and determining that an operating temperature of the transmission is below a maximum. The method also includes determining a calibrated baseline and a dissipation command for the pump. The calibrated baseline command is configured to supply the fluid based upon the requested power, and the dissipation command is configured to supply additional fluid and consume the excess power with the pump. The method operates the pump at a combined command, which is equal to the calibrated baseline command plus the dissipation command.

  13. Decontamination of main coolant pumps

    International Nuclear Information System (INIS)

    Roofthooft, R.

    1988-01-01

    Last year a number of main coolant pumps in Belgian nuclear power plants were decontaminated. A new method has been developed to reduce the time taken for decontamination and the volume of waste to be treated. The method comprises two phases: Oxidation with permanganate in nitric acid and dissolution in oxalic acid. The decontamination of main coolant pumps can now be achieved in less than one day. The decontamination factors attained range between 15 and 150. (orig.) [de

  14. Pitfalls of Insulin Pump Clocks

    Science.gov (United States)

    Reed, Amy J.

    2014-01-01

    The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients’ visits, and should remind their patients to always verify these settings. PMID:25355713

  15. Magnon transport through microwave pumping

    OpenAIRE

    Nakata Kouki; Simon Pascal; Loss Daniel

    2015-01-01

    We present a microscopic theory of magnon transport in ferromagnetic insulators (FIs). Using magnon injection through microwave pumping, we propose a way to generate magnon dc currents and show how to enhance their amplitudes in hybrid ferromagnetic insulating junctions. To this end focusing on a single FI, we first revisit microwave pumping at finite (room) temperature from the microscopic viewpoint of magnon injection. Next, we apply it to two kinds of hybrid ferromagnetic insulating juncti...

  16. Pump for extremely dangerous liquids

    Czech Academy of Sciences Publication Activity Database

    Tesaƙ, Václav

    2011-01-01

    Roč. 89, č. 7A (2011), s. 940-956 ISSN 0263-8762 R&D Projects: GA ČR GA101/07/1499; GA AV ČR IAA200760705 Institutional research plan: CEZ:AV0Z20760514 Keywords : pump * jet pump * coanda effect Subject RIV: BK - Fluid Dynamics Impact factor: 1.968, year: 2011 http://www.sciencedirect.com/science/article/pii/S0263876210003631

  17. Drinking water pollution with nickel from water boilers; Nickel-Eintrag aus Wasserkochern ins Trinkwasser

    Energy Technology Data Exchange (ETDEWEB)

    Helmers, E. [Amt fuer Umweltschutz, Stuttgart (Germany). Chemisches Inst.

    1998-07-01

    The EU is planning to drop the threshold value for nickel in drinking water down to 20 {mu}g/l (present German threshold value: 50 {mu}g/l). Since ICP-MS-screenings of spot checks of water cookers were striking with respect to nickel, emissions of electrical water cookers have been investigated systematically within this study. As a result, water cookers with open heating coils are emitting relevant amounts of nickel into the water while it is brought to the boil. Investigation of eight preused water cookers with open heating coils revealed that the boiled water contained more than 50 {mu}g Ni/l in one case, more than 20 {mu}g Ni/l in two cases and, between 10 and 20 {mu}g Ni/l in two more cases, respectively. Removing of the lime by the aid of citric acid is increasing the nickel concentrations by a factor of up to 50 (max. 640 {mu}g/l). A new device was checked in a long-term test. During standard use with tapwater, Ni concentrations fall below the detection limit of 5 {mu}g Ni/l (120 cooking events). However, after removing of the lime, 5 times of cooking were necessary in order to diminish the Ni concentrations below the limit of 20 {mu}g/l. In the case of dionized water Ni concentrations below the limit of 20 {mu}g/l. In the case of deionized water Ni concentrations remained between 94 und 190 {mu}g/l. Health risk assessment: The intake of nickel with beverages made from hot water out of these cookers is in the range of 26 {mu}g/day. Considering an alltogether dietary nickel intake of 130-170 (900) {mu}g/day, this is not beyond the scope. However, according to the fact that nickel allergies (dermatitis) are very frequent (up to 13% of the population), this source should be limited or closed. (orig.) [Deutsch] Aus Anlass der geplanten Absenkung des Trinkwassergrenzwertes fuer Nickel auf 20 {mu}g/l sowie aufgrund von Auffaelligkeiten bei Stichprobenuntersuchungen wurde das Nickel-Emissionsverhalten von elektrischen Wassererhitzern betrachtet. Hierbei erwies sich

  18. Regelwerke im multilingualen Kontext – ein Erfahrungsbericht aus einem multilingualen Verbund

    Directory of Open Access Journals (Sweden)

    JĂŒrgen KĂŒssow

    2017-10-01

    Full Text Available Der Bibliotheksverbund NEBIS (Netzwerk von Bibliotheken und Informationsstellen in der Schweiz ist der grösste Verbund wissenschaftlicher Bibliotheken der Schweiz. Ihm gehören rund 140 Bibliotheken an 154 Standorten aus allen Landesteilen der Schweiz an. Im NEBIS arbeiten Bibliotheken sowohl aus der Deutschschweiz als auch aus den Französisch und Italienisch sprechenden Landesteilen. Der Anteil der nicht-deutschsprachigen Bibliotheken betrĂ€gt im NEBIS ĂŒber 15 Prozent. Auf den Jahresbeginn 2016 hat der NEBIS-Verbund das bisher verwendete Regelwerk KIDS (Katalogisierungsregeln des IDS durch das internationale Regelwerk RDA sowie die hauseigene Normdatenbank durch die deutschorientierte Normdatenbank GND abgelöst. Der Zustand der französischsprachigen Übersetzung der RDA sowie die Übersetzung der Anwendungsregeln des D-A-CH Raumes waren eine der grössten Herausforderungen bei der EinfĂŒhrung im Verbund. In einer mehrsprachigen Umgebung mit einer monolingualen Datenbank wie der GND zu arbeiten, bedeutete besonders fĂŒr die französischsprachigen Bibliotheken viel Umstellung und FlexibilitĂ€t. Die Arbeit mit deutschen Begriffen wie zum Beispiel die Berufsbegriffe in der GND erfordert sowohl von der NEBIS-Verbundzentrale wie auch von den französischsprachigen Bibliotheken einen ausserordentlichen Effort. Der NEBIS-Verbund wird auch kĂŒnftig darauf angewiesen sein, dass die französische Übersetzung der RDA sowie die Übersetzung der Anwendungsregeln möglichst aktuell bleibt. Zudem wird auch im Bereich GND weiterhin eine flexible und geduldige Arbeitsweise aller Beteiligten erforderlich sein. The network of libraries NEBIS (Netzwerk von Bibliotheken und Informationsstellen in der Schweiz is the biggest network of scientific libraries in Switzerland. It comprises ca. 140 libraries with 154 locations in all over Switzerland. Libraries from the German, French and Italian speaking parts of the country are working together in NEBIS. More than

  19. 46 CFR 181.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 181.300 Section 181.300 Shipping COAST GUARD... EQUIPMENT Fire Main System § 181.300 Fire pumps. (a) A self priming, power driven fire pump must be..., the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not...

  20. 14 CFR 25.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 25.991 Section 25.991... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.991 Fuel pumps. (a) Main pumps. Each fuel pump required for proper engine operation, or required to meet the fuel system...

  1. 46 CFR 118.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 118.300 Section 118.300 Shipping COAST GUARD... Fire pumps. (a) A self priming, power driven fire pump must be installed on each vessel. (b) On a..., the fire pump must be capable of delivering a single hose stream from the highest hydrant, through the...

  2. Method for optimising the energy of pumps

    NARCIS (Netherlands)

    Skovmose KallesĂže, Carsten; De Persis, Claudio

    2011-01-01

    The method involves determining whether pumps (pu1, pu5) are directly assigned to loads (v1, v3) as pilot pumps (pu2, pu3) and hydraulically connected upstream of the pilot pumps. The upstream pumps are controlled with variable speed for energy optimization. Energy optimization circuits are selected

  3. METHOD FOR OPTIMIZING THE ENERGY OF PUMPS

    NARCIS (Netherlands)

    Skovmose KallesĂže, Carsten; De Persis, Claudio

    2013-01-01

    The device for energy-optimization on operation of several centrifugal pumps controlled in rotational speed, in a hydraulic installation, begins firstly with determining which pumps as pilot pumps are assigned directly to a consumer and which pumps are hydraulically connected in series upstream of

  4. 46 CFR 105.20-10 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pumps. 105.20-10 Section 105.20-10 Shipping COAST GUARD... DISPENSING PETROLEUM PRODUCTS Specific Requirements-Cargo Tanks § 105.20-10 Pumps. (a) Pumps for cargo... discharge side of pump if the pressure under shutoff conditions exceeds 60 pounds. When a relief valve is...

  5. 46 CFR 182.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ...) Highly resistant to salt water, petroleum oil, heat, and vibration. (g) If a fixed hand pump is used to... GPM). (b) A portable hand bilge pump must be: (1) Capable of pumping water, but not necessarily..., including wiring, and size and number of batteries, is designed to allow all bilge pumps to be operated...

  6. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  7. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  8. Heat recovery from beer and groundwater; Waermegewinnung aus Bier und Grundwasser

    Energy Technology Data Exchange (ETDEWEB)

    Sinn, Ruediger

    2009-04-15

    A conference and tourist hotel was constructed near the pilgrim chapel of St. Afra near Augsburg. The cost of heating and cooling was to be kept as low as possible. The problem was solved by a water-to-water heat pump and further energetic optimisations. (orig.)

  9. Schmidt. Sinfonie Nr. 1 E-Dur; Strauss. Vier sinfonische Zwischenspiele aus Intermezzo. Detroit Symphony Orchestra, Neeme JĂ€rvi / Helge GrĂŒnewald

    Index Scriptorium Estoniae

    GrĂŒnewald, Helge

    1996-01-01

    Uuest heliplaadist "Schmidt. Sinfonie Nr. 1 E-Dur; Strauss. Vier sinfonische Zwischenspiele aus Intermezzo. Detroit Symphony Orchestra, Neeme JĂ€rvi. Chandos/Koch CD 9357 (WD: 68'20") DDD (WD:114'36")

  10. Studien zur Messung von Rekonstruktionseffizienz und Untergrund der $\\tau$-Lepton-Identifikation im Zerfall $Z\\to \\tau \\tau$ beim ATLAS-Experiment aus Daten

    CERN Document Server

    Johnert, Sebastian

    2008-01-01

    In dieser Diplomarbeit werden zwei Methoden vorgestellt, mit denen τ -Leptonen in den zuk ̈nf- u tigen Daten des ATLAS-Experiments untersucht werden sollen. Den ersten Teil bildet die Be- stimmung von Missidentifikationsraten von Jets aus QCD-2-Jet-Ereignissen als τ -Leptonen. Der zweite Teil ist die Entwicklung einer Methode zur Bestimmung der τ -Rekonstruktions- und -Identifikationseffizienz relativ zur ÎŒ-Effizienz. In diesem Zusammenhang werden invariante Massen aus Z → ll-Ereignissen bestimmt, die Massen aus Z → τ τ -Ereignissen mit denen aus Z → ee und Z → ΌΌ verglichen, τ -Effizienzen gemittelt uber alle Bereiche und in verschiedenen ̈ o η-Bereichen berechnet sowie eine M ̈glichkeit zur Bestimmung von τ -Effizienzen in unterschied- lichen Transversalimpulsbereichen vorgestellt. Des Weiteren wird eine verbesserte Absch ̈tzung a des QCD-Untergrunds vorgenommen und das Verhalten der τ -Effizienz unter Ber ̈cksichtigung u des Triggers untersucht.

  11. NERATOOM work on pump development

    International Nuclear Information System (INIS)

    Hoornweg, C.J.

    1976-01-01

    The prototype pump has been manufactured by Stork Engineerings Works at Hengelo in 1969. The full-scale test on water has been carried out as part of the procedures of acceptance. Tests on sodium have been carried out in the pumptestfacility of Interatom at Bensberg (W. Germany); these tests started in March 1971 and were finished in October 1972. During that period nearly 6000 hours of pump testing were accomplished, of which 150 hours the pump was subjected to cavitation. During 30 hours the pump was subjected to a cavitation intensity of more than 3% loss of delivery head. At some occasions the loss of delivery head was 7%. The measured NPSH with the tests on sodium was 10m, whereas the NPSH obtained with the tests on water was 9m. Attempts have been made to account for this difference of NPSH-setting on the two liquids concerned. At the end of the tests on sodium (that is after the excecution of the cavitation tests) the delivery head of the pump was 2 m.l.c. less than the rated value. After dismantling the pump it appeared that the surface of the impeller vanes was roughened, especially at those parts where the original sand cast surface had not been polished. Based on the testresults and not being contradicted by calculation-results so far, our opinion is that cavitation in sodium of reactor temperature (550 0 C) most probably is of the same order of magnitude as it is in water of roomtemperature under the same conditions of NPSH, provided the same pump operates in systems that are exact replica of one another

  12. Scavenged body heat powered infusion pump

    International Nuclear Information System (INIS)

    Bell, Alexander; Ehringer, William D; McNamara, Shamus

    2013-01-01

    An infusion pump powered by body heat is investigated in this paper, with the goal of addressing the needs of dermal wound healing. The infusion pump incorporates a Knudsen gas pump, a type of thermally driven pump, to pneumatic push the pharmaceutical agent from a reservoir. Two designs are considered: an integrated pump and reservoir, and a design with cascaded pump and reservoir. Thermal models are developed for both pumps, and the simulations agree well with the experimental results. The integrated pump and reservoir design uses hydrophobic materials to prevent a flow from occurring unless the infusion pump is placed on a human body. Flow rates in the ”L min −1 range for the integrated pump and reservoir, and approximately 70 ”L min −1 for the cascaded pump were obtained. The dynamic behavior of the cascaded pump is described based on the thermal models. Multiple copies of the cascaded pump are easily made in series or parallel, to increase either the pressure or the flow rate. The flow rate of multiple pumps in series does not change, and the pressure of multiple pumps in parallel does not change. (paper)

  13. Vacuum pumping for controlled thermonuclear reactors

    International Nuclear Information System (INIS)

    Watson, J.S.; Fisher, P.W.

    1976-01-01

    Thermonuclear reactors impose unique vacuum pumping problems involving very high pumping speeds, handling of hazardous materials (tritium), extreme cleanliness requirements, and quantitative recovery of pumped materials. Two principal pumping systems are required for a fusion reactor, a main vacuum system for evacuating the torus and a vacuum system for removing unaccelerated deuterium from neutral beam injectors. The first system must pump hydrogen isotopes and helium while the neutral beam system can operate by pumping only hydrogen isotopes (perhaps only deuterium). The most promising pumping techniques for both systems appear to be cryopumps, but different cryopumping techniques can be considered for each system. The main vacuum system will have to include cryosorption pumps cooled to 4.2 0 K to pump helium, but the unburned deuterium-tritium and other impurities could be pumped with cryocondensation panels (4.2 0 K) or cryosorption panels at higher temperatures. Since pumping speeds will be limited by conductance through the ducts and thermal shields, the pumping performance for both systems will be similar, and other factors such as refrigeration costs are likely to determine the choice. The vacuum pumping system for neutral beam injectors probably will not need to pump helium, and either condensation or higher temperature sorption pumps can be used

  14. Aus der Krise lernen – Wirtschaftlichkeit durch FlexibilitĂ€t und WandlungsfĂ€higkeit sichern

    OpenAIRE

    Schmidt, Jan

    2012-01-01

    Flexible und wandelbare Fabrikstrukturen sind von hoher Bedeutung, wenn ProduktionsstĂ€tten in einem turbulenten Umfeld langfristig wettbewerbsfĂ€hig bleiben sollen; darin sind sich Forschung und Praxis einig. WĂ€hrend der jĂŒngsten weltweiten Wirtschaftskrise wurden Experten aus dem Airline-Catering-Umfeld befragt, wie Betriebe dieser Branche auf starke VerĂ€nderungen vorbereitet sind. VorgesprĂ€che und Analysen des Autors legten die Vermutung nahe, dass diese Dienstleistungsbranche besonderen...

  15. Complete CRM documentation as a basis for successfull Churn Management; Wie aus Rueckholung Vorbeugung wird. Vollstaendige Kundenkontakthistorie als Basis

    Energy Technology Data Exchange (ETDEWEB)

    Johannssen, T. [ConTakt GmbH, Itzehoe (Germany)

    2002-09-09

    The contribution explains modern customer relationship management strategies for electric utilities. The role of a complete and detailed documentation of the CRM history is explained as a basis for establishing reliable customer loyalty, winning back lost customers, or preventing customers from changing their power service. (orig./CB) [German] Erkenntnisse aus der Kundenrueckgewinnung sind eine wertvolle Grundlage fuer Kuendigungspraevention. Bei durchdachtem Vorgehen koennen sie mit den gesammelten Erfahrungen sogar schon im Vorfeld Kuendigungen verhindern. (orig./CB)

  16. Die Energiebranche am Beginn der digitalen Transformation: aus Versorgern werden Utilities 4.0

    Science.gov (United States)

    Doleski, Oliver D.

    Die traditionelle Energieversorgung befindet sich in einer ZĂ€sur. Das seit Jahrzehnten bewĂ€hrte und stabile GeschĂ€ftsmodell einer zuverlĂ€ssig planbaren, zentralen Energieerzeugung mit anschließender unidirektionaler Verteilung geriet spĂ€testens seit der Energiewende des Jahres 2011 immer mehr unter Druck. Angesichts fortschreitender Digitalisierung und Dezentralisierung einerseits und gestiegener Erwartungshaltung der Kunden gegenĂŒber "ihrem" Versorger andererseits sieht sich die Energiebranche heute einem epochalen Transformationsprozess gegenĂŒbergestellt. Bei diesem entwickeln sich aus den monopolistischen Versorgern des 19. und 20. Jahrhunderts (Utility 1.0), ĂŒber die liberalisierten Energieversorgungsunternehmen (Utility 2.0) und Energiedienstleistungsunternehmen (Utility 3.0) heutiger PrĂ€gung, die digitalen Energiedienstleistungsunternehmen (Utility 4.0) von morgen. Oliver D. Doleski beschrĂ€nkt sich in seinem Beitrag nicht auf die reine Beschreibung dieses VerĂ€nderungsprozesses an sich. Vielmehr werden darĂŒber hinaus sowohl die mit dieser Entwicklung verbundenen ĂŒbergeordneten Ziele als auch die wesentlichen Anforderungen an erfolgreiche Utilities 4.0 skizziert. Das Kapitel endet mit einem prĂ€gnanten Überblick profitabler BetĂ€tigungsfelder, die zur Sicherung der ökonomischen Zukunft von Energiekonzernen, Regionalversorgern und Stadtwerken beitragen können.

  17. Chancen und Herausforderungen der religiösen Bildung im Lebensraum Schule aus muslimischer Perspektive

    Directory of Open Access Journals (Sweden)

    Sule Dursun

    2016-06-01

    Full Text Available Dieser Beitrag basiert – mit dem Hinweis auf die zunehmende PrĂ€senz der herkunftsorientierten religiösen Einrichtungen in Europa – auf dem Argument, dass die islamisch-religiöse Bildung in den Schulen Europas ĂŒberdacht werden muss und ihr eine entscheidende Rolle zukommt. Neben den herkunftsorientierten religiösen Einrichtungen in Europa wird in diesem Beitrag die Bedeutung des islamischen Religionsunterrichts aus dem Blickwinkel des kontextualisierten Islams beleuchtet. Mittels Fallbeispielen zur religiösen Bildung am religiösen Markt (= religiöse Institutionen außerhalb des Schulraums wird in diesem Beitrag aufgezeigt, dass der islamische Religionsunterricht im Gegensatz zu den religiösen Institutionen keine Monopolkirche sein darf, in der vorwiegend eine Art Volksfrömmigkeit vermittelt wird. Opportunities and Challenges of Religious Education in Schools – A Muslim Perspective This contribution is based on the argument that the role of Islamic religious education at schools should be reconceived in relation to the growing presence of origin-oriented religious institutions in Europe. In addition to the origin-oriented religious institutions in Europe, this paper aims to present the importance of Islamic religious education from the perspective of contextualized Islam. Based on case studies for religious education in the religious market (outside the education area this paper shows that the Islamic religious education cannot offer Church`s monopoly and act like origin-oriented religious institutions to mediate popular piety.

  18. Pump Early, Pump Often: A Continuous Quality Improvement Project.

    Science.gov (United States)

    Spatz, Diane L; Froh, Elizabeth B; Schwarz, Jessica; Houng, Kathy; Brewster, Isabel; Myers, Carey; Prince, Judy; Olkkola, Michelle

    2015-01-01

    Research demonstrates that although many mothers initiate pumping for their critically ill children, few women are successful at maintaining milk supply throughout their infants' entire hospital stay. At the Garbose Family Special Delivery Unit (SDU) at the Children's Hospital of Philadelphia, we care for mothers who have critically ill infants born with complex cardiac and congenital anomalies. Human milk is viewed as a medical intervention at our institution. Therefore, nurses on the SDU wanted to ensure best practice in terms of pumping initiation. This article describes a continuous quality improvement project that ensured mothers pumped early and often. Childbirth educators can play a key role in preparing mothers who are anticipating an infant who will require hospitalization immediately post-birth.

  19. Der Zusammenhang von PartnermarktopportunitÀten aus dem Freundeskreis und der StabilitÀt von Paarbeziehungen : Eine Analyse mit den Daten des Partnermarktsurvey

    OpenAIRE

    HĂ€ring, Armando

    2014-01-01

    "Der Beitrag analysiert den Zusammenhang zwischen PartnermarktoportunitÀten aus dem Freundeskreis und der StabilitÀt von Paarbeziehungen. Unter Verwendung des theoretischen Konzepts der Theorie der Interaktionsgelegenheiten sowie von Annahmen der Austauschtheorie und der Familienökonomie, werden mögliche ZusammenhÀnge zwischen gemeinsamen Freundeskreisen mit dem Partner, Partnermarktgelegenheiten aus dem Freundeskreis (sex ratio) und der StabilitÀt von Paarbeziehungen diskutiert. Der Beitrag ...

  20. Using NOAA/AVHRR based remote sensing data and PCR method for estimation of Aus rice yield in Bangladesh

    Science.gov (United States)

    Nizamuddin, Mohammad; Akhand, Kawsar; Roytman, Leonid; Kogan, Felix; Goldberg, Mitch

    2015-06-01

    Rice is a dominant food crop of Bangladesh accounting about 75 percent of agricultural land use for rice cultivation and currently Bangladesh is the world's fourth largest rice producing country. Rice provides about two-third of total calorie supply and about one-half of the agricultural GDP and one-sixth of the national income in Bangladesh. Aus is one of the main rice varieties in Bangladesh. Crop production, especially rice, the main food staple, is the most susceptible to climate change and variability. Any change in climate will, thus, increase uncertainty regarding rice production as climate is major cause year-to-year variability in rice productivity. This paper shows the application of remote sensing data for estimating Aus rice yield in Bangladesh using official statistics of rice yield with real time acquired satellite data from Advanced Very High Resolution Radiometer (AVHRR) sensor and Principal Component Regression (PCR) method was used to construct a model. The simulated result was compared with official agricultural statistics showing that the error of estimation of Aus rice yield was less than 10%. Remote sensing, therefore, is a valuable tool for estimating crop yields well in advance of harvest, and at a low cost.

  1. Reactor feedwater pump control device

    International Nuclear Information System (INIS)

    Nishiyama, Hiroyuki.

    1990-01-01

    An amount of feedwater necessary for ensuring reactor inventory after scram is ensured automatically based on the reactor output before scram of a BWR type reactor. That is, if scram should occur, a feedwater flow rate just before the scram is stored by reactor output signals. Further, the amount of feedwater required after the scram is determined based on the output of the memory. The reactor power after the scram based on a feedwater flow rate and a main steam flow rate is inputted to an integrator, to calculate and output the amount of the feedwater flow rate (1) injected after the scram for the inventory. A coast down flowrate (2) in a case of pump trip is forecast by the output signals. Automatic trip is outputted to all turbine driving feedwater pumps when the sum of (1) and (2) exceeds a necessary and sufficient amount of feedwater required for ensuring inventory. For motor driving feedwater pumps, only a portion, for example, one of the pumps is automatically started while other pumps are stopped their operation, only in this case, to prevent excess water feeding. (I.S.)

  2. The lunar thermal ice pump

    Energy Technology Data Exchange (ETDEWEB)

    Schorghofer, Norbert [Institute for Astronomy and NASA Astrobiology Institute, University of Hawaii, Honolulu, HI 96822 (United States); Aharonson, Oded, E-mail: norbert@hawaii.edu [Helen Kimmel Center for Planetary Science, Department of Earth and Planetary Sciences, Weizmann Institute of Science, Rehovot, 76100 (Israel)

    2014-06-20

    It has long been suggested that water ice can exist in extremely cold regions near the lunar poles, where sublimation loss is negligible. The geographic distribution of H-bearing regolith shows only a partial or ambiguous correlation with permanently shadowed areas, thus suggesting that another mechanism may contribute to locally enhancing water concentrations. We show that under suitable conditions, water molecules can be pumped down into the regolith by day-night temperature cycles, leading to an enrichment of H{sub 2}O in excess of the surface concentration. Ideal conditions for pumping are estimated and found to occur where the mean surface temperature is below 105 K and the peak surface temperature is above 120 K. These conditions complement those of the classical cold traps that are roughly defined by peak temperatures lower than 120 K. On the present-day Moon, an estimated 0.8% of the global surface area experiences such temperature variations. Typically, pumping occurs on pole-facing slopes in small areas, but within a few degrees of each pole the equator-facing slopes are preferred. Although pumping of water molecules is expected over cumulatively large areas, the absolute yield of this pump is low; at best, a few percent of the H{sub 2}O delivered to the surface could have accumulated in the near-surface layer in this way. The amount of ice increases with vapor diffusivity and is thus higher in the regolith with large pore spaces.

  3. Heat pumps in western Switzerland

    International Nuclear Information System (INIS)

    Freymond, A.

    2003-01-01

    The past ten years have seen an extraordinary expansion of heat-pump market figures in the western (French speaking) part of Switzerland. Today, more than 14,000 units are in operation. This corresponds to about 18% of all the machines installed in the whole country, compared to only 10 to 12% ten years ago. This success illustrates the considerable know-how accumulated by the leading trade and industry during these years. It is also due to the promotional program 'Energy 2000' of the Swiss Federal Department of Energy that included the heat pump as a renewable energy source. Already in 1986, the Swiss Federal Institute of Technology in Lausanne was equipped with a huge heat pump system comprising two electrically driven heat pumps of 3.5 MW thermal power each. The heat source is water drawn from the lake of Geneva at a depth of 70 meters. An annual coefficient of performance of 4.5 has been obtained since the commissioning of the plant. However, most heat pump installations are located in single-family dwellings. The preferred heat source is geothermal heat, using borehole heat exchangers and an intermediate heat transfer fluid. The average coefficient of performance of these installations has been increased from 2.5 in 1995 to 3.1 in 2002

  4. Operating pumps on minimum flow

    International Nuclear Information System (INIS)

    Casada, D.A.; Li, Y.C.

    1992-01-01

    The Nuclear Regulatory Commission (NRC) staff issued Information Notice (IN) 87-59 to alert all licensees to two miniflow design concerns identified by Westinghouse. The first potential problem discussed in this IN involves parallel pump operation. If the head/capacity curve of one of the parallel pumps is greater than the other, the weaker pump may be dead-headed when the pumps are operating at low-flow conditions. The other problem related to potential pump damage as a result of hydraulic instability during low-flow operation. In NRC Bulletin 88-04, dated May 5, 1988, the staff requested all licensees to investigate and correct, as applicable, the two miniflow design concerns. The staff also developed a Temporary Instruction, Tl 2515/105, dated January 29, 1990 to inspect for the adequacy of licensee response and follow-up actions to NRC Bulletin 88-04. Oak Ridge National Laboratory has reviewed utility responses to Bulletin 88-04 under auspices of the NRC's Nuclear Plant Aging Research Program, and participated in several NRC inspections. Examples of actions that have been taken, an assessment of the overall industry response, and resultant conclusions and recommendations are presented

  5. Microelectromechanical pump utilizing porous silicon

    Science.gov (United States)

    Lantz, Jeffrey W [Albuquerque, NM; Stalford, Harold L [Norman, OK

    2011-07-19

    A microelectromechanical (MEM) pump is disclosed which includes a porous silicon region sandwiched between an inlet chamber and an outlet chamber. The porous silicon region is formed in a silicon substrate and contains a number of pores extending between the inlet and outlet chambers, with each pore having a cross-section dimension about equal to or smaller than a mean free path of a gas being pumped. A thermal gradient is provided along the length of each pore by a heat source which can be an electrical resistance heater or an integrated circuit (IC). A channel can be formed through the silicon substrate so that inlet and outlet ports can be formed on the same side of the substrate, or so that multiple MEM pumps can be connected in series to form a multi-stage MEM pump. The MEM pump has applications for use in gas-phase MEM chemical analysis systems, and can also be used for passive cooling of ICs.

  6. Ice storage facilities are worthwhile for the operation of power plants. Load management with jet pumps; Eisspeicher zahlen sich fuer Kraftwerksbetrieb aus. Lastmanagement mit Strahlpumpen

    Energy Technology Data Exchange (ETDEWEB)

    Gerhold, Richard

    2012-12-15

    The significantly better alternative to hot water tanks in thermal power plants are ice storage tanks and steam jet refrigeration plants. These facilities form ice, supply district heating and produce heat from the environment. Furthermore, these facilities produce additional peak load electricity nearly daily, so that several large power plants become dispensable. How this is possible in a simple and low-cost manner, is described in the contribution under consideration.

  7. Cryosorption vacuum pumping under fusion reactor conditions

    International Nuclear Information System (INIS)

    Watson, J.S.; Fisher, P.W.

    1977-01-01

    Experiments are in progress on cryosorption pumping using a double-chevron pump with a molecular sieve pumping surface. Studies have been made with hydrogen, deuterium, helium, and deuterium-helium at 10 -7 to 3 x 10 -3 torr. Steady pumping speeds were observed for deuterium; above 10 -4 torr the speed increased with pressure until runaway occurred. At less than 10 -6 torr and low panel loading, hydrogen pumping speeds resemble those for deuterium. At higher pressures, the pump can function by condensation or sorption, and unsteady speeds are observed. Helium pumping is always by sorption, but regions of instability have been observed and defined. Deuterium-helium pumping tests showed that deuterium condensation on the panels prevents cryosorption of helium; however, compound pumps with separate panels for helium and hydrogen will be satisfactory

  8. Experimental Realization of a Quantum Spin Pump

    DEFF Research Database (Denmark)

    Watson, Susan; Potok, R.; M. Marcus, C.

    2003-01-01

    We demonstrate the operation of a quantum spin pump based on cyclic radio-frequency excitation of a GaAs quantum dot, including the ability to pump pure spin without pumping charge. The device takes advantage of bidirectional mesoscopic fluctuations of pumped current, made spin-dependent by the a......We demonstrate the operation of a quantum spin pump based on cyclic radio-frequency excitation of a GaAs quantum dot, including the ability to pump pure spin without pumping charge. The device takes advantage of bidirectional mesoscopic fluctuations of pumped current, made spin......-dependent by the application of an in-plane Zeeman field. Spin currents are measured by placing the pump in a focusing geometry with a spin-selective collector....

  9. Multistage quantum absorption heat pumps.

    Science.gov (United States)

    Correa, Luis A

    2014-04-01

    It is well known that heat pumps, while being all limited by the same basic thermodynamic laws, may find realization on systems as "small" and "quantum" as a three-level maser. In order to quantitatively assess how the performance of these devices scales with their size, we design generalized N-dimensional ideal heat pumps by merging N-2 elementary three-level stages. We set them to operate in the absorption chiller mode between given hot and cold baths and study their maximum achievable cooling power and the corresponding efficiency as a function of N. While the efficiency at maximum power is roughly size-independent, the power itself slightly increases with the dimension, quickly saturating to a constant. Thus, interestingly, scaling up autonomous quantum heat pumps does not render a significant enhancement beyond the optimal double-stage configuration.

  10. Reactor having coolant recycling pump

    International Nuclear Information System (INIS)

    Goto, Tadashi; Karatsuka, Shigeki; Yamamoto, Hajime.

    1991-01-01

    In a coolant recycling pump for an LMFBR type reactor, vertical grooves are formed to a static portion which surrounds a pump shaft as far as the lower end thereof. Sodium mists present in an annular gap of the pump shaft form a rotational flow, lose its centrifugal force at the grooved portion and are collected positively to the grooved portion. Further, since the rotational flow in the grooved channel is in a state of a cavity flow, the pressure is released in the grooved portion and a secondary eddy current is formed thereby providing a depressurized state. Accordingly, by a synergestic effect of the centrifugal force and the cavity flow, sodium mists can be recovered completely. (T.M.)

  11. Reactor coolant pump transportation incident

    International Nuclear Information System (INIS)

    Noce, D.

    1992-01-01

    This paper reports on an incident, which occurred on August 27, 1991, in which a Reactor Coolant Pump motor en route from Surry Power Station to Westinghouse repair facilities struck the overpass at the junction of Interstate 64 and Jefferson Avenue in Newport News, Virginia. The transport container that housed the reactor coolant pump motor failed to clear the overpass. The force of the impact dislodged the container and motor from the truck bed, and it landed on the acceleration land and road shoulder. Upon impact, the container broke open and exposed the reactor coolant pump motor. Incidental radioactively contaminated water that remained in the motor coolers drained onto the road, contaminating the aggregate as well as the underlying gravel

  12. Continuous improvement of pump seals

    International Nuclear Information System (INIS)

    Wong, W.; Eyvindson, A.; Rhodes, D.B.

    2003-01-01

    Pump seal reliability continues to be an area needing improvement and ongoing vigilance. Methods have been developed for identifying and assessing factors relating to seal performance, selecting the most relevant ones for a specific station, and then focusing on the most significant aspects and how to improve. Discussion invariably addresses maintenance practices, seal design, monitoring capabilities, operating conditions, transients, and pump and motor design. Success in reliability improvement requires ongoing dialogue among the station operators, pump manufacturers and seal designers. AECL CAN-seals lead the nuclear industry in reliability and seal life. They effectively save operators millions of dollars in outage time and person-rem. This paper describes some of the significant developments in AECL's ongoing program in seal R and D, as well as recent new installations following the most demanding seal qualification programs to date. (author)

  13. Optical pumping and xenon NMR

    International Nuclear Information System (INIS)

    Raftery, M.D.

    1991-11-01

    Nuclear Magnetic Resonance (NMR) spectroscopy of xenon has become an important tool for investigating a wide variety of materials, especially those with high surface area. The sensitivity of its chemical shift to environment, and its chemical inertness and adsorption properties make xenon a particularly useful NMR probe. This work discusses the application of optical pumping to enhance the sensitivity of xenon NMR experiments, thereby allowing them to be used in the study of systems with lower surface area. A novel method of optically-pumping 129 Xe in low magnetic field below an NMR spectrometer and subsequent transfer of the gas to high magnetic field is described. NMR studies of the highly polarized gas adsorbed onto powdered samples with low to moderate surface areas are now possible. For instance, NMR studies of optically-pumped xenon adsorbed onto polyacrylic acid show that xenon has a large interaction with the surface. By modeling the low temperature data in terms of a sticking probability and the gas phase xenon-xenon interaction, the diffusion coefficient for xenon at the surface of the polymer is determined. The sensitivity enhancement afforded by optical pumping also allows the NMR observation of xenon thin films frozen onto the inner surfaces of different sample cells. The geometry of the thin films results in interesting line shapes that are due to the bulk magnetic susceptibility of xenon. Experiments are also described that combine optical pumping with optical detection for high sensitivity in low magnetic field to observe the quadrupoler evolution of 131 Xe spins at the surface of the pumping cells. In cells with macroscopic asymmetry, a residual quadrupolar interaction causes a splitting in the 131 Xe NMR frequencies in bare Pyrex glass cells and cells with added hydrogen

  14. FED pumped limiter configuration issues

    International Nuclear Information System (INIS)

    Haines, J.R.; Fuller, G.M.

    1983-01-01

    Impurity control in the Fusion Engineering Device (FED) is provided by a toroidal belt pumped limiter. Limiter design issues addressed in this paper are (1) poloidal location of the limiter belt, (2) shape of the limiter surface facing the plasma, and (3) whether the belt is pumped from one or both sides. The criteria used for evaluation of limiter configuration features were sensitivity to plasma-edge conditions and ease of maintenance and fabrication. The evaluation resulted in the selection of a baseline FED limiter that is located at the bottom of the device and has a flat surface with a single leading edge

  15. FED pumped limiter configuration issues

    International Nuclear Information System (INIS)

    Haines, J.R.; Fuller, G.M.

    1983-01-01

    Impurity control in the Fusion Engineering Device (FED) is provided by a toroidal belt pumped limiter. Limiter design issues addressed in this paper are (1) poloidal location of the limiter belt, (2) shape of the limiter surface facing the plasma, and (3) whether the belt is pumped from one or both sides. The criteria used for evaluation of limiter configuration features were sensitivity to plasma edge conditions and ease of maintenance and fabrication. The evaluation resulted in the selection of a baseline FED limiter that is located at the bottom of the device and has a flat surface with a single leading edge

  16. TFCX pumped limiter and vacuum pumping system design and analysis

    International Nuclear Information System (INIS)

    Haines, J.R.

    1985-04-01

    Impurity control system design and performance studies were performed in support of the Tokamak Fusion Core Experiment (TFCX) pre-conceptual design. Efforts concentrated on pumped limiter and vacuum pumping system design configuration, thermal/mechanical and erosion lifetime performance of the limiter protective surface, and helium ash removal performance. The reference limiter design forms a continuous toroidal belt at the bottom of the device and features a flat surface with a single leading edge. The vacuum pumping system features large vacuum ducts (diameter approximately 1 m) and high-speed, compound cryopumps. Analysis results indicate that the limiter/vacuum pumping system design provides adequate helium ash removal. Erosion, primarily by disruption-induced vaporization and/or melting, limits the protective surface lifetime to about one calendar year or only about 60 full-power hours of operation. In addition to evaluating impurity control system performance for nominal TFCX conditions, these studies attempt to focus on the key plasma physics and engineering design issues that should be addressed in future research and development programs

  17. A longitudinally-pumped laser (specifically, pulse-pumped lasers)

    Energy Technology Data Exchange (ETDEWEB)

    Wojtkowiak, J

    1979-10-15

    A laser is proposed that employs travelling-wave pumping, for which no less than four electrodes, interconnected with coaxial transmission lines with a feed network, are placed at specific distances from each other in a discharge channel filled with an active medium. An expression is given for determining the length of the coaxial sections.

  18. Simulations of longitudinally pumped dye laser amplifier

    International Nuclear Information System (INIS)

    Takehisa, Kiwamu; Takemori, Satoshi

    1995-01-01

    Simulations of a copper laser pumped dye laser amplifier and new designs of the longitudinally pumped dye laser amplifier are presented. The simulations take the consideration of the amplified spontaneous emission (ASE). The new designs utilize a center-hole reflector instead of a dichroic mirror. The simulation results indicate that the poor spatial overlap between the pump beam and the dye beam in the transverse pumping not only reduces the laser output power, but also generates ASE strongly. The results also indicate that the longitudinal pumping is as efficient as the transverse pumping. (author)

  19. Using the heat of the Rickenbach railway tunnel; Waermenutzung aus dem Rickentunnel. Mehrzweckhalle Kaltbrunn

    Energy Technology Data Exchange (ETDEWEB)

    Cotting, R.

    2000-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) describes a project that uses the geothermal energy extracted from the drainage water of the over eight kilometre long Rickenbach railway tunnel in eastern Switzerland. This tunnel was one of five evaluated as part of the 'Energy 2000' programme. The report describes how the heat is used to provide space heating for a multi-purpose communal hall, a kindergarten and - in a later phase - for a local housing development and a schoolhouse. The calculation of heating energy requirements and the energetic potential of the drainage water are described, as is the heat pump installation and the water pre-treatment plant. Also, the refrigerant used in the system's heat pump is discussed and the data collection and processing systems are described. Figures are given on the temperature, flow and energy data acquired as well as on the drainage water's pH-value and the heat pump's characteristics and efficiency. The economics of the installation are examined and operational aspects are commented on.

  20. Peaceful uses of nuclear weapon plutonium; Friedliche Verwertung von Plutonium aus Kernwaffen

    Energy Technology Data Exchange (ETDEWEB)

    Burtak, F. [Siemens AG Bereich Energieerzeugung (KWU), Erlangen (Germany)

    1996-06-01

    In 1993, the U.S.A. and the CIS signed Start 2 (the Strategic Arms Reduction Treaty) in which they committed themselves the reduce their nuclear weapon arsenals to a fraction of that of 1991. For forty-five years the antagonism between the superpowers had been a dominating factor in world history, determining large areas of social life. When Start 2 will have been completed in 2003, some 200 t of weapon grade plutonium and some 2000 t of highly enriched uranium (Heu) will arise from dismantling nuclear weapons. In the absence of the ideological ballast of the debate about Communism versus Capitalism of the past few decades there is a chance of the grave worldwide problem of safe disposal and utilization of this former nuclear weapon material being solved. Under the heading of `swords turned into plowshares`, plutonium and uranium could be used for peaceful electricity generation. (orig.) [Deutsch] 1993 unterzeichneten die USA und GUS das Start-2-Abkommen (Strategic Arms Reduction Treaty), in dem sie sich zur Verringerung der Anzahl ihrer Nuklearwaffen auf einen Bruchteil des Bestandes von 1991 verpflichten. 45 Jahre lang stellte die Auseinandersetzung der Supermaechte einen dominierenden Faktor der Weltpolitik dar und bestimmte weite Teile des gesellschaftlichen Lebens. Mit der geplanten Erfuellung von Start 2 im Jahr 2003 werden ca. 200 t waffengraediges Plutonium und ca. 2000 t highly enriched uranium (Heu) aus der Demontage der Kernwaffen anfallen. Ohne den ideologischen Ballast der vergangenen jahrezehntelangen Auseinandersetzung zwischen `Kommunismus` und `Kapitalismus` besteht die Chance, das gravierende weltweite Problem der sicheren Entsorgung und Verwertung dieses ehemaligen Kernwaffenmaterials zu loesen. Unter dem Motto `Schwerter zu Pflugscharen` koennte das Plutonium und Uran zur friedlichen Elektrizitaetserzeugung genutzt werden. (orig.)

  1. Large-volume heat storage tank made of GFK; Grosswaermespeichertank aus GFK

    Energy Technology Data Exchange (ETDEWEB)

    Buehl, J.; Schultheis, P. [Technische Univ. Ilmenau (Germany). Fachgebiet Technische Thermodynamik

    1998-12-31

    The Technical University of Ilmenau, the company Verbundwerkstoff- und Kunststoffanwendungstechnik Schoenbrunn, the Institute for Aerospace and Light-weight construction of Dresden University with its approved testing facilities for plastics and the Institute for Construction Engineering in Berlin and several other institutions co-operated since 1996 in developing a concept for a series of long-term heat storage tanks up to 6,000 cubic metres storage volume made of plastic (GFK components) with a combined thermal insulation. A model tank (sandwich body with proportional thermal insulation layer and selected mixed laminates) with a volume of 1.5 cubic metres was built and installed in November 1996. The tank has been continuously operated at various test levels. The experiment proves the longevity of the materials used. (orig.) [Deutsch] In Zusammenarbeit der TU Ilmenau mit der Fa. Verbundwerkstoff - und Kunststoffanwendungstechnik Schoenbrunn und dem Institut fuer Luftfahrttechnik und Leichtbau Dresden, seiner akkredierten Pruefstelle fuer Kunststoffe, in Abstimmung mit dem Institut fuer Bautechnik Berlin und weiteren Einrichtungen und Partnern wird seit 1996 an einem Konzept fuer eine Typenreihe Langzeitwaermespeicher bis vorerst 6.000 m{sup 3} Speichervolumen aus Kunststoff (GFK-Komponenten) und kombinierter integrierter thermischer Isolation gearbeitet. Im Vorfeld dieser Entwicklung wurde auf der Basis vorausgewaehlter Materialien und Kompositionen ein Musterspeicher (ein Sandwich - Modellkoerper mit proportionaler Waermedaemmschicht sowie ausgewaehlten Mischlaminaten) mit einem Speichervolumen von 1,5 m{sup 3} realisiert. Dieser Musterspeicher wurde im November 1996 installiert und wird seither kontinuierlich in den entsprechenden Erprobungsstufen betrieben. Der Nachweis der Langlebigkeit der eingesetzten Materialien wurde experimentell erbracht. (orig.)

  2. NĂŁo basta gerar, tem que participar?: um estudo sobre a ausĂȘncia paterna

    Directory of Open Access Journals (Sweden)

    Sabrina Daiana CĂșnico

    2014-03-01

    Full Text Available O presente estudo buscou conhecer, por meio de uma abordagem qualitativa, quais as possĂ­veis razĂ”es para a ausĂȘncia paterna na vida dos filhos apĂłs o rompimento conjugal. Para tanto, foram entrevistados pais que participaram do serviço de mediação familiar e tiveram acordo homologado judicialmente em um NĂșcleo de PrĂĄticas JudiciĂĄrias Gratuitas. A pesquisa foi realizada utilizando a tĂ©cnica de entrevistas semidirigidas de questĂ”es abertas, e os resultados analisados por meio da anĂĄlise de conteĂșdo temĂĄtica. Os pais relataram terem se sentido vĂ­timas de um golpe - o golpe da barriga - que teve por objetivo mantĂȘlos em um relacionamento em vias de dissolução. Assim, apresentaram dificuldades em estabelecer um vĂ­nculo afetivo com esse filho, visto que amĂĄ-lo seria assumir a efetividade de tal golpe. Ademais, foram identificadas semelhanças na histĂłria familiar dos participantes que envolviam a paternidade, as quais, por nĂŁo terem sido problematizadas, nĂŁo se tornaram objeto de reflexĂŁo, o que levou Ă  repetição. Por fim, entende-se que o estudo aponta a importĂąncia do cuidado com relação aos efeitos da dissolução conjugal no que tange ao exercĂ­cio dos papĂ©is parentais, em especial, Ă  paternidade.

  3. Heat Radiators for Electromagnetic Pumps

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Report proposes use of carbon/carbon composite radiators in electromagnetic coolant pumps of nuclear reactors on spacecraft. Carbon/carbon composite materials function well at temperatures in excess of 2,200 K. Aluminum has melting temperature of only 880 K.

  4. Improvement to liquid metal pumps

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    This invention concerns the coolant pumps of nuclear reactors. It resolves the problems of structures which have to withstand high temperatures, the difficulties in keeping the multiple bearings of the shaft aligned, the excessive fluid flows, the risks of scoring and seizing-up by self welding, the need for narrow machining tolerances and the difficulties of access for inspection and repairs [fr

  5. Pumps for nuclear power stations

    International Nuclear Information System (INIS)

    Ogura, Shiro

    1979-01-01

    16 nuclear power plants are in commercial operation in Japan, and nuclear power generation holds the most important position among various substitute energies. Hereafter also, it is expected that the construction of nuclear power stations will continue because other advantageous energy sources are not found. In this paper, the outline of the pumps used for BWR plants is described. Nuclear power stations tend to be large scale to reduce the construction cost per unit power output, therefore the pumps used are those of large capacity. The conditions to be taken in consideration are high temperature, high pressure, radioactive fluids, high reliability, hydrodynamic performances, aseismatic design, relevant laws and regulations, and quality assurance. Pumps are used for reactor recirculation system, control rod driving hydraulic system, boric acid solution injecting system, reactor coolant purifying system, fuel pool cooling and purifying system, residual heat removing system, low pressure and high pressure core spraying systems, and reactor isolation cooling system, for condensate, feed water, drain and circulating water systems of turbines, for fresh water, sea water, make-up water and fire fighting services, and for radioactive waste treating system. The problems of the pumps used for nuclear power stations are described, for example, the requirement of high reliability, the measures to radioactivity and the aseismatic design. (Kako, I.)

  6. Vertical reactor coolant pump instabilities

    International Nuclear Information System (INIS)

    Jones, R.M.

    1985-01-01

    The investigation conducted at the Tennessee Valley Authority's Sequoyah Nuclear Power Plant to determine and correct increasing vibrations in the vertical reactor coolant pumps is described. Diagnostic procedures to determine the vibration causes and evaluate the corractive measures taken are also described

  7. Cotransporters as molecular water pumps

    DEFF Research Database (Denmark)

    Zeuthen, Thomas; MacAulay, Nanna

    2002-01-01

    Molecular water pumps are membrane proteins of the cotransport type in which a flux of water is coupled to substrate fluxes by a mechanism within the protein. Free energy can be exchanged between the fluxes. Accordingly, the flux of water may be relatively independent of the external water chemical...

  8. Pierre Gorce working on a helium pump.

    CERN Multimedia

    1975-01-01

    This type of pump was designed by Mario Morpurgo, to circulate liquid helium in superconducting magnets wound with hollow conductors. M. Morpurgo, Design and construction of a pump for liquid helium, CRYIOGENICS, February 1977, p. 91

  9. Nuclear power plant safety related pump issues

    Energy Technology Data Exchange (ETDEWEB)

    Colaccino, J.

    1996-12-01

    This paper summarizes of a number of pump issues raised since the Third NRC/ASME Symposium on Valve and Pump Testing in 1994. General issues discussed include revision of NRC Inspection Procedure 73756, issuance of NRC Information Notice 95-08 on ultrasonic flow meter uncertainties, relief requests for tests that are determined by the licensee to be impractical, and items in the ASME OM-1995 Code, Subsection ISTB, for pumps. The paper also discusses current pump vibration issues encountered in relief requests and plant inspections - which include smooth running pumps, absolute vibration limits, and vertical centrifugal pump vibration measurement requirements. Two pump scope issues involving boiling water reactor waterlog and reactor core isolation cooling pumps are also discussed. Where appropriate, NRC guidance is discussed.

  10. Pumps for German pressurized water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Dernedde, R.

    1984-01-01

    The article describes the development of a selection of pumps which are used in the primary coolant system and the high-pressure safety injection system and feed water system during the past 2 decades. The modifications were caused by the step-wise increasing power output of the plants from 300 MW up to 1300 MW. Additional important influences were given be the increased requirements for quality assurance and final-documentation. The good operating results of the delivered pumps proved that the reliability is independent of the volume of the software-package. The outlook expects that consolidation will be followed by additional steps for the order processing of components for the convoy pumps. KW: main coolant pump; primary system; boiler feed pump; reactor pump; secondary system; barrel insert pump; pressure water reactor; convoy pump; state of the art.

  11. 33 CFR 183.524 - Fuel pumps.

    Science.gov (United States)

    2010-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.524 Fuel pumps. (a) Each...) If tested under § 183.590, each fuel pump, as installed in the boat, must not leak more than five...

  12. Alignment analysis of a vertical sodium pump

    International Nuclear Information System (INIS)

    Gupta, V.K.; Fair, C.E.

    1981-01-01

    With the objective of identifying important alignment features of pumps such as FFTF, HALLAM, EBR II, PNC, PHENIX, and CRBR, alignment of the vertical sodium pump for the Clinch River Breeder Reactor Plant (CRBRP) is investigated. The CRBRP pump includes a flexibly coupled pump shaft and motor shaft, two oil-film tilting-pad hydrodynamic radial bearings in the motor plus a vertical thrust bearing, and two sodium hydrostatic bearings straddling the double-suction centrifugal impeller in the pump. The assembled CRBRP prototype pump shows smooth predictable vibration behavior experienced during water test. An ealier swing check of the pump shaft about the motor shaft hub demonstrated that the pump is relatively insensitive to manufacturing and assembly tolerances, a consequence of close dimensional control and unique alignment features. (orig./GL)

  13. Human Aorta Is a Passive Pump

    Science.gov (United States)

    Pahlevan, Niema; Gharib, Morteza

    2012-11-01

    Impedance pump is a simple valveless pumping mechanism that operates based on the principles of wave propagation and reflection. It has been shown in a zebrafish that a similar mechanism is responsible for the pumping action in the embryonic heart during early stages before valve formation. Recent studies suggest that the cardiovascular system is designed to take advantage of wave propagation and reflection phenomena in the arterial network. Our aim in this study was to examine if the human aorta is a passive pump working like an impedance pump. A hydraulic model with different compliant models of artificial aorta was used for series of in-vitro experiments. The hydraulic model includes a piston pump that generates the waves. Our result indicates that wave propagation and reflection can create pumping mechanism in a compliant aorta. Similar to an impedance pump, the net flow and the flow direction depends on the frequency of the waves, compliance of the aorta, and the piston stroke.

  14. CRBRP sodium circulating pump design evaluation

    International Nuclear Information System (INIS)

    Marrujo, F.; Cook, M.; Manners, L.; Cothran, H.

    1977-12-01

    The following topics are discussed: (1) primary sodium pump design concept; (2) pump level control system; (3) resolution of design problems in stress analysis, dynamics analysis, and mechanical design; (4) model testing; (5) planned performance tests; and (6) fabrication status

  15. Nuclear power plant safety related pump issues

    International Nuclear Information System (INIS)

    Colaccino, J.

    1996-01-01

    This paper summarizes of a number of pump issues raised since the Third NRC/ASME Symposium on Valve and Pump Testing in 1994. General issues discussed include revision of NRC Inspection Procedure 73756, issuance of NRC Information Notice 95-08 on ultrasonic flow meter uncertainties, relief requests for tests that are determined by the licensee to be impractical, and items in the ASME OM-1995 Code, Subsection ISTB, for pumps. The paper also discusses current pump vibration issues encountered in relief requests and plant inspections - which include smooth running pumps, absolute vibration limits, and vertical centrifugal pump vibration measurement requirements. Two pump scope issues involving boiling water reactor waterlog and reactor core isolation cooling pumps are also discussed. Where appropriate, NRC guidance is discussed

  16. Cost Effective, Scalable Optically Pumped Molecular Laser

    National Research Council Canada - National Science Library

    Nicholson, Jeff

    2001-01-01

    An optically pumped, For laser was demonstrated operating at 4.0 micrometers. This is the first demonstration of an HBr laser by direct optical pumping of the 0 right arrow 3 vibrational overtone band at 1.34 micrometers...

  17. Blocking device especially for circulating pumps

    International Nuclear Information System (INIS)

    Susil, J.; Vychodil, V.; Lorenc, P.

    1976-01-01

    The claim of the invention is a blocking device which blocks reverse flow occurring after the shutdown of circulating pumps, namely in the operation of nuclear power plants or in pumps with a high delivery head. (F.M.)

  18. High power diode pumped solid state lasers

    International Nuclear Information System (INIS)

    Solarz, R.; Albrecht, G.; Beach, R.; Comaskey, B.

    1992-01-01

    Although operational for over twenty years, diode pumped solid state lasers have, for most of their existence, been limited to individual diodes pumping a tiny volume of active medium in an end pumped configuration. More recent years have witnessed the appearance of diode bars, packing around 100 diodes in a 1 cm bar which have enabled end and side pumped small solid state lasers at the few Watt level of output. This paper describes the subsequent development of how proper cooling and stacking of bars enables the fabrication of multi kill average power diode pump arrays with irradiances of 1 kw/cm peak and 250 W/cm 2 average pump power. Since typical conversion efficiencies from the diode light to the pumped laser output light are of order 30% or more, kW average power diode pumped solid state lasers now are possible

  19. Compact and highly efficient laser pump cavity

    Science.gov (United States)

    Chang, Jim J.; Bass, Isaac L.; Zapata, Luis E.

    1999-01-01

    A new, compact, side-pumped laser pump cavity design which uses non-conventional optics for injection of laser-diode light into a laser pump chamber includes a plurality of elongated light concentration channels. In one embodiment, the light concentration channels are compound parabolic concentrators (CPC) which have very small exit apertures so that light will not escape from the pumping chamber and will be multiply reflected through the laser rod. This new design effectively traps the pump radiation inside the pump chamber that encloses the laser rod. It enables more uniform laser pumping and highly effective recycle of pump radiation, leading to significantly improved laser performance. This new design also effectively widens the acceptable radiation wavelength of the diodes, resulting in a more reliable laser performance with lower cost.

  20. Pumped energy transfer stations (STEP)

    International Nuclear Information System (INIS)

    Tournery, Jean-Francois

    2015-12-01

    As objectives of development are high for renewable energies (they are supposed to cover 50 per cent of new energy needs by 2035), pumped energy transfer stations are to play an important role in this respect. The author first discusses the consequences of the development of renewable energies on the exploitation of electric grids: issue of intermittency for some of them, envisaged solutions. Then, he addresses one of the solutions: the storage of electric power. He notices that increasing the potential energy of a volume of water is presently the most mature solution to face massive needs of the power system. Dams and pumped energy transfer stations represent now almost the whole installed storage power in the world. The author then presents these pumped energy transfer stations: principle, brief history (the first appeared in Italy and Switzerland at the end of the 1890's). He indicates the various parameters of assessment of such stations: maximum stored energy, installed power in pumping mode and turbine mode, time constant, efficiency, level of flexibility. He discusses economic issues. He describes and comments the operation of turbine-pump groups: ternary groups, reversible binary groups. He discusses barriers to be overcome and technical advances to be made for varying speed groups and for marine stations. He finally gives an overview (table with number of stations belonging to different power ranges, remarkable installations) of existing stations in China, USA, Japan, Germany, Austria, Spain, Portugal, Italy, Switzerland, France and UK, and indicate predictions regarding storage needs at the world level. Some data are finally indicated for the six existing French installations

  1. Solar Thermal Power Generation 2000: solar-assisted district heating, tight sealing of pit water storage tanks made out of pre-stressed concrete; Solarthermie 2000, TP3: Solarunterstuetzte Nahwaermeversorgung: Dichte Heisswasser - Waermespeicher aus Hochleistungsbeton. Erdbeckenspeicher aus Hochleistungsbeton

    Energy Technology Data Exchange (ETDEWEB)

    Reineck, K.H.; Lichtenfels, A.; Schlaich, J. [Stuttgart Univ. (Germany). Inst. fuer Konstruktion und Entwurf 2

    1998-12-31

    In 1996 the two large heat storage tanks in Hamburg-Bramfeld (4,750 cubic metres) and Friedrichshafen-Wiggenhausen (12,000 cubic metres) were built out of concrete with an inner stainless steel lining. This was a big step towards economic efficiency. The research project ``Tight sealing of pit water storage tanks made out of pre-stressed concrete`` was launched by the BMBF in order to show that the concrete construction will not only bear loads but also ensure sealing. Building costs for underground hot water storage tanks could then be reduced by at least 25%. The first results of this research project are presented. The paper also contains recommendations for the further development of heat storage tanks built with pre-stressed concrete. (orig.) [Deutsch] Im Jahre 1996 wurden die beiden grossen Waermespeicher in Hamburg-Bramfeld mit einem Volumen von 4.750 m{sup 3} und in Friedrichshafen-Wiggenhausen mit 12.000 m{sup 3} aus Beton mit innenliegender Edelstahlauskleidung fertiggestellt. Mit dem Bau dieser beiden Grossspeicher konnte ein richtungsweisender Schritt hin zur Wirtschaftlichkeit gemacht werden, wie man es in Studien vor 15 Jahren nicht fuer moeglich hielt. Mit dem BMBF - Forschungsvorhaben `Dichte Heisswasser - Waermespeicher aus Hochleistungsbeton` soll gezeigt werden, dass das Betontragwerk nicht nur Lasten abtragen sondern auch die Funktion der Abdichtung uebernehmen kann. Damit sollen die Baukosten fuer unterirdische Heisswasser-Waermespeicher um mindestens 25% gesenkt werden. Es werden die ersten Ergebnisse dieses Forschungsvorhabens mitgeteilt und Empfehlungen fuer die weitere Entwicklung von Waermespeichern aus Hochleistungsbeton gegeben. (orig.)

  2. 46 CFR 169.559 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 169.559 Section 169.559 Shipping COAST GUARD... Firefighting Equipment Firefighting Equipment § 169.559 Fire pumps. (a) Each sailing school vessel must be equipped with fire pumps as required in Table 169.559(a). Table 169.559(a)—Fire Pumps Length Exposed and...

  3. Intermittency and Inflexibility Blister Pump Impress Factors

    OpenAIRE

    Mlakar, Boơtjan; Zupančič, Cvetko

    2011-01-01

    Divisional centralized heating and cooling system, cogeneratton system of heat and power and power-gas cogeneration system. In order to further fully and reasonably use the heat in doubleeffect absorption units, double-stage bubble pump must be involved in the adoption o u pump replacing the traditional mechanical solution pump. It was designed a secon generator based on a solar pump-free lithium bromide absorption chiller system. The expenmen adopts the lunate thermosiphon elevation tube, ef...

  4. Pump efficiency in solar-energy systems

    Science.gov (United States)

    1978-01-01

    Study investigates characteristics of typical off-the-shelf pumping systems that might be used in solar systems. Report includes discussion of difficulties in predicting pump efficiency from manufacturers' data. Sample calculations are given. Peak efficiencies, flow-rate control, and noise levels are investigated. Review or theory of pumps types and operating characteristics is presented.

  5. Baxter elastomeric pumps: Feasibility of weight estimates.

    Science.gov (United States)

    Chambers, Carole R; Pabia, Mica; Sawyer, Michael; Tang, Patricia A

    2017-09-01

    Purpose Elastomeric pumps are used to infuse a 46-h fluorouracil protocol and patients are asked to visually inspect the pump daily. The pump has a variability of ±10% and there are additional patient variables that can increase this. The feasibility of weighing the pump rather than a visual inspection along with the secondary objective to confirm the pump's variability in real world conditions was undertaken. Methods Empty pumps were weighed using both pharmacy and kitchen scales. Pumps upon completion of the 46-h infusion were also weighed using both pharmacy and kitchen scales. Results The kitchen scale was as accurate as the pharmacy grade scale. Disconnected pumps showed the expected variability from using these infusor pumps along with a few showing greater variability likely due to patient variables. Conclusion Weighing pumps appears to be feasible both at the pharmacy and home level. Next steps would be to weigh pumps during the infusion to validate an alternate method to simple visual inspection for patients to confirm proper infusing of the pump at their home.

  6. Maternal response to two electric breast pumps

    Science.gov (United States)

    Mechanical characteristics of breast pumps have been shown to influence milk extraction and hormone release in laboratory settings. However, few studies evaluate impact of differences in pump design on long-term breastfeeding success. This study evaluated the impact of a novel pump design on milk ex...

  7. 46 CFR 169.654 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Bilge pumps. 169.654 Section 169.654 Shipping COAST... Electrical Bilge Systems § 169.654 Bilge pumps. (a) Vessels of less than 65 feet in length must have a portable hand bilge pump having a maximum capacity of 5 gpm. (b) In addition to the requirements of...

  8. A novel high efficiency solar photovoltalic pump

    NARCIS (Netherlands)

    Diepens, J.F.L.; Smulders, P.T.; Vries, de D.A.

    1993-01-01

    The daily average overall efficiency of a solar pump system is not only influenced by the maximum efficiency of the components of the system, but just as much by the correct matching of the components to the local irradiation pattern. Normally centrifugal pumps are used in solar pump systems. The

  9. 76 FR 43218 - Commercial and Industrial Pumps

    Science.gov (United States)

    2011-07-20

    .... EERE-2011-BT-STD-0031] RIN 1904-AC54 Commercial and Industrial Pumps AGENCY: Department of Energy... efficient product designs for commercial and industrial pumps. The comment period closed on July 13, 2011... commercial and industrial pumps. The comment period is extended to September 16, 2011. DATES: The comment...

  10. Pump Propels Liquid And Gas Separately

    Science.gov (United States)

    Harvey, Andrew; Demler, Roger

    1993-01-01

    Design for pump that handles mixtures of liquid and gas efficiently. Containing only one rotor, pump is combination of centrifuge, pitot pump, and blower. Applications include turbomachinery in powerplants and superchargers in automobile engines. Efficiencies lower than those achieved in separate components. Nevertheless, design is practical and results in low consumption of power.

  11. Pump system characterization and reliability enhancement

    International Nuclear Information System (INIS)

    Staunton, R.H.

    1998-01-01

    Pump characterization studies were performed at the Oak Ridge National Laboratory (ORNL) to review and analyze six years (1990-1995) of data from pump systems at domestic nuclear plants. The studies considered not only pumps and pump motors but also pump-related circuit breakers and turbine drives (i.e., the pump system). One significant finding was that the number of 'significant' failures of the pump circuit breaker exceeds the number of significant failures of the pump itself. The study also shows how regulatory code testing was designed for the pump only and therefore did not lead to the discovery of other significant pump system failures. Potential diagnostic technologies, both experimental and mature, suitable for on-line and off-line pump testing were identified. The study does not select or recommend technologies but proposes diagnostic technologies and monitoring techniques that should be further evaluated/developed for making meaningful and critically-needed improvements in the reliability of the pump system. (author)

  12. 46 CFR 108.471 - Water pump.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  13. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...

  14. Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Reza Arefizadeh

    2017-05-01

    CONCLUSIONS: Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR.

  15. Off-pump versus on-pump coronary artery bypass grafting for ischaemic heart disease

    DEFF Research Database (Denmark)

    MĂžller, Christian H; Penninga, Luit; Wetterslev, JĂžrn

    2012-01-01

    Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear.......Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear....

  16. Small Scroll Pump for Cryogenic Liquids, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation is a compact, reliable, light weight, electrically driven pump capable of pumping cryogenic liquids, based on scroll pump technology. This pump will...

  17. Assessing the energy efficiency of pumps and pump units background and methodology

    CERN Document Server

    Bernd Stoffel, em Dr-Ing

    2015-01-01

    Assessing the Energy Efficiency of Pumps and Pump Units, developed in cooperation with Europump, is the first book available providing the background, methodology, and assessment tools for understanding and calculating energy efficiency for pumps and extended products (pumps+motors+drives). Responding to new EU requirements for pump efficiency, and US DOE exploratory work in setting pump energy efficiency guidelines, this book provides explanation, derivation, and illustration of PA and EPA methods for assessing energy efficiency. It surveys legislation related to pump energy eff

  18. AusLAMP long period magnetotellurics: progress update and new insights into Victorian geology and mineral prospectivity

    Science.gov (United States)

    Chopping, R. G.; Duan, J.; Czarnota, K.; Kemp, T.

    2016-12-01

    It is becoming generally accepted that world-class mineral deposits have a footprint on a scale of the lithosphere. For this reason, Australia has embarked on the Australian Lithospheric Architecture Magnetotelluric Project (AusLAMP) to map the conductivity of the mid to lower crust and the lithospheric mantle. AusLAMP is a collaborative project between Geoscience Australia, State and Territory Geological Surveys and Universities. The project aims to collect long-period magnetotelluric data across the Australian continent on a nominal 0.5x0.5° ( 55x55 km) grid. To date, more than 450 sites have been acquired including all sites for the state of Victoria, two-thirds of sites in South Australia and Tasmania, and approximately 25 stations in Western Australia. Progress is ramping up with acquisition to turn to the state of New South Wales, the remainder of South Australia and also acquisition in northern Australia. To support this increasing acquisition activity, additional instruments have been purchased to add to those already in Australia. 3D inversion results are now available for AusLAMP Victoria. In collaboration with the National Computational Infrastructure (NCI), the 3D ModEM codes were optimised for use on the NCI's supercomputer, speeding up large-scale inversions by an order of magnitude. The results of these inversions indicate anomalously conductive lithospheric mantle associated with the central region of Victoria which contains significant mineral deposits and prospectivity, and also anomalous resistive lithosphere associated with the southern extension of the dynamically supported Australian Alps and the Newer Volcanics Province. Modelled conductivities are also consistent with mantle xenolith data from central Victoria. Within the crust, the dominant trend of the data is along elongate north-eastern corridors of conductive material. These results shed new questions on the geological history of this region and the lithospheric architecture of the

  19. Recycling systems and material flows from the viewpoint of thermal waste treatment; Kreislaufwirtschaft- und Stoffstrombetrachtungen aus Sicht der thermischen Abfallbehandlung

    Energy Technology Data Exchange (ETDEWEB)

    Johnke, B. [Umweltbundesamt, Berlin (Germany); Mast, P.G. [Tauw Umwelt GmbH, Berlin (Germany)

    1998-09-01

    Material stream analysis can serve as a basis for decisions on which materials should be kept in circulation, and in what quantity, and which materials it is better to remove from the recycling system and dispose of as waste. Wastes destined for disposal are mostly transferred to waste treatment plants and landfills. The role of thermal treatment as part of the disposal system is to destroy or decompose organic pollutants contained in the waste, concentrate and remove inorganic pollutants, make the heat arising during the treatment process available for use as energy, and make the greatest possible physical use of the treatment residues. The present paper reviews the current regulations for the promotion of recycling and investigates selected material streams and the fate of these materials. In connection with the residue quality of household waste incineration slag as a thermal waste treatment product it also considers the influence of waste management measures on wastes destined for disposal. [Deutsch] Stoffstrombetrachtungen koennen als Grundlage fuer Entscheidungen dienen, welche Stoffe in welchem Umfang im Kreislauf verbleiben oder wieder integriert werden sollten und welche besser als Abfall zur Beseitigung aus dem Kreislaufsystem auszuschleusen sind. Fuer Abfaelle zur Beseitigung wird diese Aufgabe i.d.R. von thermischen Abfallbehandlungsanlagen und Deponien uebernommen. Im Rahmen der Entsorgung kommt der thermischen Behandlung dabei die Aufgabe zu, die im Abfall zur Beseitigung enthaltenen organischen Schadstoffe zu zerstoeren oder abzubauen, anorganische Schadstoffe aufzukonzentrieren und auszuschleusen, die bei dem Behandlungsprozess entstehende Waerme einer weitgehenden Energienutzung zuzufuehren und die Rueckstaende aus der Behandlung so weit wie moeglich stofflich zu verwerten. Nachfolgend sollen insbesondere die Regelungen zur Unterstuetzung der Kreislaufwirtschaft, ausgewaehlte Stofffluesse und der Verbleib dieser Stoffe und Materialien und der

  20. Hydraulic optimization of 'S' characteristics of the pump-turbine for Xianju pumped storage plant

    International Nuclear Information System (INIS)

    Liu, W C; Zheng, J S; Cheng, J; Shi, Q H

    2012-01-01

    The pump-turbine with a rated power capacity of 375MW each at Xianju pumped storage plant is the most powerful one under construction in China. In order to avoid the instability near no-load conditions, the hydraulic design of the pump-turbine has been optimized to improving the 'S' characteristic in the development of the model pump-turbine. This paper presents the cause of 'S' characteristic of a pump-turbine by CFD simulation of the internal flow. Based on the CFD analysis, the hydraulic design optimization of the pump-turbine was carried out to eliminate the 'S' characteristics of the machine at Xianju pumped storage plant and a big step for removing the 'S' characteristic of a pump-turbine has been obtained. The model test results demonstrate that the pump-turbine designed for Xianju pumped storage plant can smoothly operate near no-load conditions without an addition of misaligned guide vanes.

  1. Atividade fĂ­sica como discriminador da ausĂȘncia de hipertensĂŁo arterial em homens adultos

    Directory of Open Access Journals (Sweden)

    Francisco Jose Gondim Pitanga

    2014-12-01

    Full Text Available Introdução: Diversos estudos epidemiolĂłgicos demonstram que a atividade fĂ­sica reduz a pressĂŁo arterial, porĂ©m a quantidade necessĂĄria para que estes benefĂ­cios sejam alcançados permanece especulativa. Objetivo: Analisar a quantidade (duração e intensidade de atividade fĂ­sica em seus diferentes domĂ­nios (trabalho, deslocamento, atividade domĂ©stica e tempo livre como discriminador da ausĂȘncia de hipertensĂŁo arterial em adultos do sexo masculino. MĂ©todos: Estudo transversal realizado na cidade de Lauro de Freitas, Bahia, Brasil com amostra constituĂ­da por 220 indivĂ­duos do sexo masculino com idade superior a 18 anos. Foram construĂ­das diversas curvas Receiver Operating Characteristic (ROC e comparadas Ă s ĂĄreas sobre as mesmas entre a quantidade de atividade fĂ­sica em seus diferentes domĂ­nios e a ausĂȘncia de hipertensĂŁo arterial. Verificou-se tambĂ©m a sensibilidade e especificidade para a quantidade de atividade fĂ­sica necessĂĄria para prevenção de hipertensĂŁo arterial. Foi utilizado o intervalo de confiança a 95%. Resultados: Entre os diferentes domĂ­nios de atividade fĂ­sica analisados encontrou-se maior significĂąncia estatĂ­stica nas ĂĄreas sob a curva ROC para a atividade fĂ­sica no trabalho e no tempo livre. A caminhada nĂŁo foi boa discriminadora para a ausĂȘncia de hipertensĂŁo arterial em nenhum dos domĂ­nios analisados. Observou-se tambĂ©m que 180 min/semana de atividade fĂ­sica moderada, acumulada nos diferentes domĂ­nios foi o melhor ponto de corte para discriminar a ausĂȘncia de hipertensĂŁo arterial. ConclusĂŁo: A prĂĄtica da atividade fĂ­sica, principalmente de intensidade moderada, com duração de pelo menos 180 min/semana deve ser sugerida para indivĂ­duos do sexo masculino visando contribuir para a prevenção da hipertensĂŁo arterial.

  2. Atividade fĂ­sica como discriminador da ausĂȘncia de hipertensĂŁo arterial em homens adultos

    OpenAIRE

    Francisco Jose Gondim Pitanga; Luiz Alberto Bastos de Almeida; Marcela Mota Freitas; Cristiano Penas Seara Pitanga; Carmem Cristina Beck

    2014-01-01

    Introdução: Diversos estudos epidemiolĂłgicos demonstram que a atividade fĂ­sica reduz a pressĂŁo arterial, porĂ©m a quantidade necessĂĄria para que estes benefĂ­cios sejam alcançados permanece especulativa. Objetivo: Analisar a quantidade (duração e intensidade) de atividade fĂ­sica em seus diferentes domĂ­nios (trabalho, deslocamento, atividade domĂ©stica e tempo livre) como discriminador da ausĂȘncia de hipertensĂŁo arterial em adultos do sexo masculino. MĂ©todos: Estudo transversal realizado...

  3. Advances in heat pump systems: A review

    International Nuclear Information System (INIS)

    Chua, K.J.; Chou, S.K.; Yang, W.M.

    2010-01-01

    Heat pump systems offer economical alternatives of recovering heat from different sources for use in various industrial, commercial and residential applications. As the cost of energy continues to rise, it becomes imperative to save energy and improve overall energy efficiency. In this light, the heat pump becomes a key component in an energy recovery system with great potential for energy saving. Improving heat pump performance, reliability, and its environmental impact has been an ongoing concern. Recent progresses in heat pump systems have centred upon advanced cycle designs for both heat- and work-actuated systems, improved cycle components (including choice of working fluid), and exploiting utilisation in a wider range of applications. For the heat pump to be an economical proposition, continuous efforts need to be devoted to improving its performance and reliability while discovering novel applications. Some recent research efforts have markedly improved the energy efficiency of heat pump. For example, the incorporation of a heat-driven ejector to the heat pump has improved system efficiency by more than 20%. Additionally, the development of better compressor technology has the potential to reduce energy consumption of heat pump systems by as much as 80%. The evolution of new hybrid systems has also enabled the heat pump to perform efficiently with wider applications. For example, incorporating a desiccant to a heat pump cycle allowed better humidity and temperature controls with achievable COP as high as 6. This review paper provides an update on recent developments in heat pump systems, and is intended to be a 'one-stop' archive of known practical heat pump solutions. The paper, broadly divided into three main sections, begins with a review of the various methods of enhancing the performance of heat pumps. This is followed by a review of the major hybrid heat pump systems suitable for application with various heat sources. Lastly, the paper presents novel

  4. Pump Application as Hydraulic Turbine – Pump as Turbine (PaT)

    OpenAIRE

    Rusovs, D

    2009-01-01

    The paper considers pump operation as hydraulic turbine with purpose to produce mechanical power from liquid flow. The Francis hydraulic turbine was selected for comparison with centrifugal pump in reverse operation. Turbine and centrifugal pump velocity triangles were considered with purpose to evaluate PaT efficiency. Shape of impeller blades for turbine and pumps was analysed. Specific speed calculation is carried out with purpose to obtain similarity in pump and turbine description. For ...

  5. Production-integrated emission reduction: Examples from power plant engineering; Produktionsintegrierte Emissionsminderung - Beispiele aus der Kraftwirtschaft

    Energy Technology Data Exchange (ETDEWEB)

    Reich, J.; Brueggendick, H. [STEAG AG, Essen (Germany)

    2002-07-01

    verfolgt. Darueber hinaus hat eine Nichtverwertbarkeit der Reststoffe gravierende Auswirkungen fuer die Wirtschaftlichkeit. Verwertung oder Nicht-Verwertung der Reststoffe aus der Kohleverbrennung kann zu einer Differenz bei den Stromerzeugungskosten von 15% fuehren. Die Parameter Brennstoffe, Feuerungstechnik, Rauchgasreinigungstechnik, Produktverwertung sind je nach Standort individuell zu bewerten. Das Spannungsfeld liegt zwischen hochwertigen Brennstoffen und Produkten, fuer die in der Anlagentechnik auch entsprechende Investitionen erforderlich sind (z.B. Staubfeuerung mit Kalkstein- oder Ammoniakalischer Waesche) oder einfacheren Verfahren mit zum Teil geringeren Investitionskosten (z.B. Rauchgasreinigung mittels Trocken- oder Halbtrockenverfahren). Es ist nicht wirtschaftlichm in eine Anlage zu investieren und hochwertige Produkte zu erzeugen, wenn fuer deren Abnahme keine Infrastruktur existiert. Kohlekraftwerke sind unter Nutzung der technischen Moeglickeiten fuer den jeweiligen Standort zu optimieren. (orig.)

  6. Westeuropas Wiederaufbau – Made in Germany? Baumaterial aus Deutschland im Versailler Vertrag

    Directory of Open Access Journals (Sweden)

    Anna Karla

    2016-11-01

    Full Text Available To date, the historiography of reparations after World War I has a predominant focus on cash. The article proposes considering non-cash contributions a constitutive part of the Treaty of Versailles and investigating their impact on the post-World War I order. Contemporary debates on the supply of building materials to northern France illustrate the expectations on the German side that were raised by the promise of such deliveries in kind: Policymakers hoped that deliveries in kind would reduce the overall sum of reparations; smart entrepreneurs hoped for lucrative business, for instance from the sale of prefabricated houses; and trade unions saw new prospects for German workers and German building materials. Though deliveries in kind to the areas undergoing reconstruction in northern France were in practice small, the related debates disclose new perspectives on the post-war history. This example serves as a case in point for the potential of applying theoretical considerations about the social dimension of materiality to the context of the Treaty of Versailles and its consequences. Die Geschichtsschreibung der Reparationen nach dem Ersten Weltkrieg handelt bislang vor allem von Geld. Dieser Aufsatz plĂ€diert dafĂŒr, auch die Sachlieferungen als einen wesentlichen Bestandteil des Versailler Vertrags zu interpretieren. Exemplarisch wird erprobt, wie sich theoretische Überlegungen zur sozialen Dimension von Dingen auf die Geschichte des Versailler Vertrags und seiner Folgen anwenden lassen. Anhand der zeitgenössischen Diskussionen ĂŒber geplante Lieferungen von Baumaterial nach Nordfrankreich lĂ€sst sich nachvollziehen, dass man auf deutscher Seite mit diesen Reparationsleistungen durchaus Erwartungen verknĂŒpfte: Aus Sicht der Politik sollten Sachlieferungen dazu beitragen, die Gesamtsumme der Reparationen zu mindern. Findige Unternehmen hofften schon 1919 auf eintrĂ€gliche GeschĂ€fte, etwa durch den Verkauf von FertighĂ€usern. Auch die

  7. Spontaneous intracerebral hemorrhage: the clinical neuroradiological view; Die spontane intrazerebrale Blutung aus klinisch-neuroradiologischer Sicht

    Energy Technology Data Exchange (ETDEWEB)

    Reith, W. [Technische Hochschule Aachen (Germany). Klinikum

    1999-10-01

    verlaesslicher mit der Magnetresonanztomographie nachweisbar. Aus der unterschiedlichen Signalgebung in den verschiedenen MR-Sequenzen kann auf das Alter der Blutung geschlossen werden. Die Ursache einer nicht-traumatischen intrazerebralen Blutung ist in ueber 60% der Faelle eine Hypertonie, weniger haeufig die Folgen des Alkoholismus, Gefaessfehlbildungen oder die Amyloidangiopathie. Seltener sind Blutgerinnungsstoerungen, Traumen, Tumoren, Venenthrombosen oder Intoxikationen die Ursachen einer intrazerebralen Blutung. Nicht-traumatische intrazerebrale Blutungen treten am haeufigsten zwischen dem 5.-7. Lebensjahrzehnt auf. Bei juengeren Patienten sind vor allem Gefaessfehlbildungen als Ursache zu beruecksichtigen. Insbesondere bei juengeren Patienten sollte zur aetiopathogentischen Klaerung eine zerebrale Angiographie durchgefuehrt werden. Spontane intrazerebrale Blutungen werden in der Regel konservativ behandelt, ausser man verspricht sich von der operativen Dekompression eine Verbesserung des klinischen Zustandes. (orig.)

  8. Operating experience in the gasification of municipal waste and other waste at the `secondary feedstocks recycling centre` (SVZ) Schwarze Pumpe; Betriebserfahrungen zur Vergasung von Hausmuell und anderen Abfaellen im Sekundaerrohstoffverwertungszentrum Schwarze Pumpe (SVZ)

    Energy Technology Data Exchange (ETDEWEB)

    Buttker, B. [Sekundaerrohstoffverwertungszentrum Schwarze Pumpe GmbH, Schwarze Pumpe (Germany)

    1998-12-31

    The business purpose of SVZ Schwarze Pumpe is the production of synthesis gas from hydro-carbon-containing waste material and the use of synthesis gas in gas production or energy generation. For synthesis gas production, the techniques of packed-bed pressure gasification (FDV) and entrained-flow gasification (FSV) are used in close interconnection. Process control is such that only inert slags accrue, apart from the final products methanol and gypsum as well as generated energy in the form of electricity, process steam and heat. Currently, the following materials are mainly used in gasification: plastic materials after being subjected to conditioning, industrial and municipal sewage sludge, shredded goods, contaminated used wood, contaminated used oil, oil components obtained from oil/water mixtures, and slurry products. A special in-house know-how for waste oil gasification, and for the combined gasification of solid waste and coal by packed-bed pressure gasification with gradual stepping-up of the waste portion was realized. (orig.) [Deutsch] Der Geschaetszweck des SVZ Schwarze Pumpe besteht in der Herstellung von Synthesegas aus kohlenwasserstoffhaltigen Einsatzstoffen und in der stofflichen und energetischen Nutzung des Wertstoffes Synthesegas. Zur Synthesegasgewinnung werden die Verfahren der Festbettdruckvergasung (FDV) und Flugstromvergasung (FSV) in einer engen verbundwirtschaftlichen Kopplung angewandt. Die Betriebsfuehrung ist so gestaltet, dass neben den Endprodukten Methnaol und Gips sowie erzeugter Energie in Form von Strom, Prozessdampf und Waerme nur noch inerte Schlacken entstehen. Die Haupteinsatzprodukte fuer die Vergasung sind ggw. aufbereitete Altkunststoffe, industrielle und kommunale Klaerschlaemme, Shreddergueter, kontaminiertes Altholz, kontaminierte Altoele, Oelkomponenten, die aus Oel-Wasser-Gemischen gewonnen werden, und Slurry-Produkte. Es wurde ein spezielles Betriebs-Know-how zur Abfalloel-Vergasung und zur kombinierten Vergasung

  9. Enhance pump reliability through improved inservice testing

    International Nuclear Information System (INIS)

    Healy, J.J.

    1990-01-01

    EPRI has undertaken a study to assess the effectiveness of existing testing programs to accurately monitor and predict performance changes before either pump performance degrades or an actual failure occurs. Anticipated changes in inservice testing techniques are directed towards enhancing the validity of test data, ensuring its repeatability, and avoiding deterioration of the pump assembly. There is a new-found interest in test programs of all types that has occurred, in part, because of an increase in reported pump degradation and pump failure. Inservice testing of pumps, which has long been a basis for assuring operability, has apparently produced an opposite effect; namely, the appearance of a reduction in reliability

  10. Evaluation of personal air sampling pumps

    International Nuclear Information System (INIS)

    Ritter, P.D.; Novick, V.J.; Alvarez, J.L.; Huntsman, B.L.

    1987-01-01

    Personal air samplers are used to more conveniently obtain breathing zone samples from individuals over periods of several hours. Personal air sampling pumps must meet minimum performance levels under all working conditions to be suitable for use in radiation protection programs. In addition, the pumps should be simple to operate and as comfortable to wear as possible. Ten models of personal air sampling pumps were tested to evaluate their mechanical performance and physical characteristics. The pumps varied over a wide range in basic performance and operating features. Some of the pumps were found to have adequate performance for use in health physics air sampling applications. 3 references, 2 figures, 5 tables

  11. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.; Buttner, Ulrich; Yi, Ying

    2016-01-01

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  12. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.

    2016-03-31

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  13. Liquid metal pump for nuclear reactors

    International Nuclear Information System (INIS)

    Allen, H.G.; Maloney, J.R.

    1975-01-01

    A pump for use in pumping high temperature liquids at high pressures, particularly liquid metals used to cool nuclear reactors is described. It is of the type in which the rotor is submerged in a sump but is fed by an inlet duct which bypasses the sump. A chamber, kept full of fluid, surrounds the pump casing into which fluid is bled from the pump discharge and from which fluid is fed to the rotor bearings and hence to the sump. This equalizes pressure inside and outside the pump casing and reduces or eliminates the thermal shock to the bearings and sump tank

  14. The pumping of hydrogen and helium by sputter-ion pumps

    International Nuclear Information System (INIS)

    Welch, K.M.; Pate, D.J.; Todd, R.J.

    1992-01-01

    The pumping of hydrogen in diode and triode sputter-ion pumps is discussed. The type of cathode material used in these pumps is shown to have a significant impact on the effectiveness with which hydrogen is pumped. Examples of this include data for pumps with aluminum and titanium-alloy cathodes. Diode pumps with aluminum cathodes are shown to be no more effective in the pumping of hydrogen than in the pumping of helium. The use of titanium or titanium alloy anodes is also shown to measurably impact on the speed of these pumps at.very low pressures. This stems from the fact that hydrogen is x10 6 more soluble in titanium than in stainless steel. Hydrogen becomes resident in the anodes because of fast neutral burial. Lastly, quantitative data are given for the He speeds and capacities of both noble and conventional diode and triode pumps. The effectiveness of various pump regeneration procedures, subsequent to the pumping of He, is reported.These included bakeout and N 2 glow discharge cleaning. The comparative desorption of He with the subsequent pumping of N 2 is reported on. The N 2 speed of these pumps was used as the benchmark for defining the size of the pumps vs. their respective He speeds

  15. Geothermal Heat Pump Benchmarking Report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1997-01-17

    A benchmarking study was conducted on behalf of the Department of Energy to determine the critical factors in successful utility geothermal heat pump programs. A Successful program is one that has achieved significant market penetration. Successfully marketing geothermal heat pumps has presented some major challenges to the utility industry. However, select utilities have developed programs that generate significant GHP sales. This benchmarking study concludes that there are three factors critical to the success of utility GHP marking programs: (1) Top management marketing commitment; (2) An understanding of the fundamentals of marketing and business development; and (3) An aggressive competitive posture. To generate significant GHP sales, competitive market forces must by used. However, because utilities have functioned only in a regulated arena, these companies and their leaders are unschooled in competitive business practices. Therefore, a lack of experience coupled with an intrinsically non-competitive culture yields an industry environment that impedes the generation of significant GHP sales in many, but not all, utilities.

  16. A regenerative elastocaloric heat pump

    DEFF Research Database (Denmark)

    Engelbrecht, Kurt; Eriksen, Dan; Dallolio, Stefano

    2016-01-01

    A large fraction of global energy use is for refrigeration and air-conditioning, which could be decarbonized if efficient renewable energy technologies could be found. Vapour-compression technology remains the most widely used system to move heat up the temperature scale after more than 100 years...... a regenerative elastocaloric heat pump that exhibits a temperature span of 15.3 K on the water side with a corresponding specific heating power up to 800 W kg−1 and maximum COP (coefficient-of-performance) values of up to 7. The efficiency and specific heating power of this device exceeds those of other devices...... based on caloric effects. These results open up the possibility of using the elastocaloric effect in various cooling and heat-pumping applications....

  17. Pumped storage - necessary and sensible

    International Nuclear Information System (INIS)

    Kiener, E.

    2006-01-01

    This comprehensive article takes a look at the long-established technique of using pumped storage schemes to temporarily store electricity. Here, excess power is used to pump water back into high-level reservoirs during low-load periods so that it can be used to generate electricity during peak periods. Ecological and energy-loss aspects are discussed as are the objections raised by environmental agencies. An overview of the present situation and the operation of such installations in Switzerland is provided. Future developments in this area and the role played in the European power system are discussed. Comparisons are made between hydro-electric peak power production and that using gas turbines and other systems. In particular, the efficiencies and the carbon dioxide loading involved are looked at. Also, the situation with power generation using new renewables is examined and the economic prerequisites for the operation of such schemes are looked at

  18. Fusion reactor high vacuum pumping

    International Nuclear Information System (INIS)

    Sedgley, D.W.; Walthers, C.R.; Jenkins, E.M.

    1992-01-01

    This paper reports on recent experiments which have shown the practicality of using activated carbon (coconut charcoal) at 4K to pump helium and hydrogen isotopes for a fusion reactor. Both speed and capacity for deuterium/helium and tritium/helium-3 mixtures were satisfactory. The long-term effects of tritium on the charcoal/cement system developed by Grumman and LLNL was now known; therefore a program was undertaken to see what, if any, effect long-term tritium exposure has on the cryosorber. Several charcoal on aluminum test samples were subjected to six months exposure of tritium at approximately 77 K. The tritium was scanned several times with a residual gas analyzer and the speed-capacity performance of the samples was measured before, approximately one-third way through, and after the exposure. Modest effects were noted which would not seriously restrict the use of charcoal as a cryosorber for fusion reactor high-vacuum pumping applications

  19. 40 CFR 65.116 - Quality improvement program for pumps.

    Science.gov (United States)

    2010-07-01

    ... (for example, piston, horizontal or vertical centrifugal, gear, bellows); pump manufacturer; seal type and manufacturer; pump design (for example, external shaft, flanged body); materials of construction... program. (4) Pump or pump seal inspection. The owner or operator shall inspect all pumps or pump seals...

  20. Particles pumping in Tore Supra

    International Nuclear Information System (INIS)

    Bonnel, P.; Chappuis, P.; Lipa, M.

    1989-01-01

    TORE SUPRA and its peripheral equipments are provided with routine clean high vacuum by turbomolecular pumping. During plasma discharges large quantity of very hot gases activating at plasma edge and plasma density in scrape off layer has to be controlled before they strike violently solid wall provoking increase in impurities content and make density up to disruptive level. A Magnetic Ergodic Divertor made of six winding structures - MED - six Vertical Pumped Limiters - VPL - and one Horizontal Pumped Limiter - HPL - are set in the vacuum chamber in order to cope with plasma-wall interactions and neutral gas recycling. Each apparatus is equipped at front side with thermal shield respectively made of polycristallin and pyrolitic graphite bolted on stainless steel support for MED and HPL whereas for VPL it is made of CFC Aerolor 05 brazed on hardened copper. The total heat removal capacity of these plasma facing components is 12 MW. Design of particles collection openings and ducts conductance allow 10% of capture efficiency, that means for TORE SUPRA a flux of 3 x 10 21 particles/second has to be sorbed by water cooled titanium getter pumps, settled at rear side. All those facilities were put into plasma operation at the beginning of 1989 for a short time. Preliminary observations go along with theoretical predictions, that actions in scrappe-off layer may provoke effects in bulk plasma. Very first results drawn out, show that particle collection and heat removal were effective by MED, VPL and HPL and that plasma behaviour was not disturbed by their presence and actions but instead tendency to improvement was observed

  1. A Linear Electromagnetic Piston Pump

    Science.gov (United States)

    Hogan, Paul H.

    Advancements in mobile hydraulics for human-scale applications have increased demand for a compact hydraulic power supply. Conventional designs couple a rotating electric motor to a hydraulic pump, which increases the package volume and requires several energy conversions. This thesis investigates the use of a free piston as the moving element in a linear motor to eliminate multiple energy conversions and decrease the overall package volume. A coupled model used a quasi-static magnetic equivalent circuit to calculate the motor inductance and the electromagnetic force acting on the piston. The force was an input to a time domain model to evaluate the mechanical and pressure dynamics. The magnetic circuit model was validated with finite element analysis and an experimental prototype linear motor. The coupled model was optimized using a multi-objective genetic algorithm to explore the parameter space and maximize power density and efficiency. An experimental prototype linear pump coupled pistons to an off-the-shelf linear motor to validate the mechanical and pressure dynamics models. The magnetic circuit force calculation agreed within 3% of finite element analysis, and within 8% of experimental data from the unoptimized prototype linear motor. The optimized motor geometry also had good agreement with FEA; at zero piston displacement, the magnetic circuit calculates optimized motor force within 10% of FEA in less than 1/1000 the computational time. This makes it well suited to genetic optimization algorithms. The mechanical model agrees very well with the experimental piston pump position data when tuned for additional unmodeled mechanical friction. Optimized results suggest that an improvement of 400% of the state of the art power density is attainable with as high as 85% net efficiency. This demonstrates that a linear electromagnetic piston pump has potential to serve as a more compact and efficient supply of fluid power for the human scale.

  2. Optical Pumping of Molecular Gases

    Science.gov (United States)

    1976-04-01

    ser emission ott a The typical experimental apparatus is shown i.- Fig. *series of green and yellow molecular B-X’-basnd transi- 2. For B-bantd optical...with A, at 0. 473 pim and that Na2 may operate as a flash -lamp -pumped laser X,... at 0. 54 umn the Doppler widths are AwD - 12.42 source with buffer

  3. -pumping pyrophosphatase in pepper plants

    KAUST Repository

    Vigani, Gianpiero; Rolli, Eleonora; Marasco, Ramona; Dell'Orto, Marta; Michoud, Gregoire; Soussi, Asma; Raddadi, Noura; Borin, Sara; Sorlini, Claudia; Zocchi, Graziano; Daffonchio, Daniele

    2018-01-01

    It has been previously shown that the transgenic overexpression of the plant root vacuolar proton pumps H+ -ATPase (V-ATPase) and H+ -PPase (V-PPase) confer tolerance to drought. Since plant-root endophytic bacteria can also promote drought tolerance, we hypothesize that such promotion can be associated to the enhancement of the host vacuolar proton pumps expression and activity. To test this hypothesis, we selected two endophytic bacteria endowed with an array of in vitro plant growth promoting traits. Their genome sequences confirmed the presence of traits previously shown to confer drought resistance to plants, such as the synthesis of nitric oxide and of organic volatile organic compounds. We used the two strains on pepper (Capsicuum annuum L.) because of its high sensitivity to drought. Under drought conditions, both strains stimulated a larger root system and enhanced the leaves' photosynthetic activity. By testing the expression and activity of the vacuolar proton pumps, H+ -ATPase (V-ATPase) and H+ -PPase (V-PPase), we found that bacterial colonization enhanced V-PPase only. We conclude that the enhanced expression and activity of V-PPase can be favoured by the colonization of drought-tolerance-inducing bacterial endophytes. This article is protected by copyright. All rights reserved.

  4. -pumping pyrophosphatase in pepper plants

    KAUST Repository

    Vigani, Gianpiero

    2018-05-22

    It has been previously shown that the transgenic overexpression of the plant root vacuolar proton pumps H+ -ATPase (V-ATPase) and H+ -PPase (V-PPase) confer tolerance to drought. Since plant-root endophytic bacteria can also promote drought tolerance, we hypothesize that such promotion can be associated to the enhancement of the host vacuolar proton pumps expression and activity. To test this hypothesis, we selected two endophytic bacteria endowed with an array of in vitro plant growth promoting traits. Their genome sequences confirmed the presence of traits previously shown to confer drought resistance to plants, such as the synthesis of nitric oxide and of organic volatile organic compounds. We used the two strains on pepper (Capsicuum annuum L.) because of its high sensitivity to drought. Under drought conditions, both strains stimulated a larger root system and enhanced the leaves\\' photosynthetic activity. By testing the expression and activity of the vacuolar proton pumps, H+ -ATPase (V-ATPase) and H+ -PPase (V-PPase), we found that bacterial colonization enhanced V-PPase only. We conclude that the enhanced expression and activity of V-PPase can be favoured by the colonization of drought-tolerance-inducing bacterial endophytes. This article is protected by copyright. All rights reserved.

  5. Enhanced wall pumping in JET

    International Nuclear Information System (INIS)

    Ehrenberg, J.; Harbour, P.J.

    1991-01-01

    The enhanced wall pumping phenomenon in JET is observed for hydrogen or deuterium plasmas which are moved from the outer (larger major radius) limiter position either to the inner wall or to the top/bottom wall of the vacuum vessel. This phenomenon is analysed by employing a particle recycling model which combines plasma particle transport with particle re-emission from and retention within material surfaces. The model calculates the important experimentally observable quantities, such as particle fluxes, global particle confinement time, plasma density and density profile. Good qualitative agreement is found and, within the uncertainties, the agreement is quantitative if the wall pumping is assumed to be caused by two simultaneously occurring effects: (1) Neutral particle screening at the inner wall and the top/bottom wall is larger than that at the outer limiter because of different magnetic topologies at different poloidal positions; and (2) although most of the particles (≄ 90%) impacting on the wall can be promptly re-emitted, a small fraction (≀ 10%) of them must be retained in the wall for a period of time which is similar to or larger than the global plasma particle confinement time. However, the wall particle retention time need not be different from that of the outer limiter, i.e. pumping can occur when there is no difference between the material properties of the limiter and those of the wall. (author). 45 refs, 18 figs

  6. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  7. Annual report 1999 of the air pollution monitoring network of the German Federal Environmental Agency; Jahresbericht 1999 aus dem Messnetz des Umweltbundesamtes

    Energy Technology Data Exchange (ETDEWEB)

    Beilke, S.; Uhse, K. [comps.

    2000-12-01

    In this annual report the results of the air pollution monitoring network of the German Federal Environmental Agency (FEA) are presented for the year 1999. The network consists of 23 stations (9 stations with personnel and 14 automatically working container stations) which are situated in rural areas. As the data set was thoroughly quality controlled reliable statements on trends can be made. (orig.) [German] Im vorliegenden Jahresbericht werden die Ergebnisse aus dem Messnetz des Umweltbundesamtes fuer das Jahr 1999 vorgestellt, interpretiert und mit den Messungen aus frueheren Jahren verglichen. Das UBA-Messnetz besteht heute aus insgesamt 23 in laendlichen Regionen gelegenen Stationen, wovon 9 Messstellen personell besetzt und 14 automatisch arbeitende Containerstationen sind. Die Datensaetze sind in sich homogen, d.h. es wurden im Verlauf der Jahre keine gravierenden Veraenderungen an den Messbedingungen vorgenommen, weder bei der Probenahme noch bei der Analytik. Die Daten wurden einer eingehenden Qualitaetspruefung unterzogen, sowohl intern als auch bei internationalen Ringvergleichen der Analysenverfahren. (orig.)

  8. The Au-S bond and SAM-protein contact in long-range electron transfer of pure and biomimetic metalloproteins via functionalized alkanethiol linkers

    DEFF Research Database (Denmark)

    Chi, Qijin; Ford, Michael J.; Halder, Arnab

    disentangled a wealth of data to identify the nature of the crucial Au-S contact, all suggesting prevalence of a Au(0)-thiyl radical unit. Molecular packing is further determined by the SAM molecular structure and involves binding either to Au-atoms mined out of the surface or directly to a flat surface. We...... functionalized alkanethiols have emerged as core linkers. We have studied molecular linking in the long-range ET (LRET) processes in detail using electrochemistry, in situ STM and AFM, and electronic structure computations. A focus is the electronic structure of the Au-S link and the SAM packing. We have...... is exceedingly sensitive to the structure of the thiol-based SAM molecules, testifying to the crucial importance of SAM packing and Au-S binding, and of the SAM link to the protein. Some of the subtleties are illustrated simpler by similar size (5-6 nm) nanoparticles (NPs). Biomimetic NPs must possess a certain...

  9. The electric dipole moments in the ground states of gold oxide, AuO, and gold sulfide, AuS.

    Science.gov (United States)

    Zhang, Ruohan; Yu, Yuanqin; Steimle, Timothy C; Cheng, Lan

    2017-02-14

    The B 2 ÎŁ - - X 2 Π 3/2 (0,0) bands of a cold molecular beam sample of gold monoxide, AuO, and gold monosulfide, AuS, have been recorded at high resolution both field free and in the presence of a static electric field. The observed electric field induced splittings and shifts were analyzed to produce permanent electric dipole moments, Ό→ el , of 2.94±0.06 D and 2.22±0.05 D for the X 2 Π 3/2 (v = 0) states of AuO and AuS, respectively. A molecular orbital correlation diagram is used to rationalize the trend in ground state Ό→ el values for AuX (X = F, Cl, O, and S) molecules. The experimentally determined Ό→ el are compared to those computed at the coupled-cluster singles and doubles (CCSD) level augmented with a perturbative inclusion of triple excitations (CCSD(T)) level of theory.

  10. Production of oil and coke from sludges containing organic pollutants; Gewinnung von Oel und Koks aus organisch belasteten Schlaemmen

    Energy Technology Data Exchange (ETDEWEB)

    Steger, M [Martin Steger GmbH, Eggenfelden (Germany); Meissner, W; Herold, R [Max Aicher Umwelttechnik GmbH, Freilassing (Germany)

    1998-09-01

    Since the mid-eighties, Messrs. Max Aicher Umwelttechnik GmbH at Hammerau, Germany have been investigating sewage sludge pyrolysis. Laboratory experiments and semi-industrial investigations led to the construction of a combined sludge drying and conversion plant (``Aicher sludge recycling process``), in which the organic sludge fraction is converted into recyclable or combustible oils. Carbon is obtained as a by-product in solid form as conversion coke which can be utilized. Apart from sewage sludge, also industrial sludges with high organic fractions can be processed, e.g. sludges and sewage sludges from petroleum processing. (orig.) [Deutsch] In der Bundesrepublik Deutschland beschaeftigt sich die Max Aicher Umwelttechnik GmbH in Hammerau seit Mitte der Achtzigerjahre mit der Niedertemperaturkonvertierung (Pyrolyse) von Klaerschlamm. Versuche im Labor- und im halbtechnischen Massstab fuehrten zur Realisierung einer betriebstechnischen Anlage mit den Komponenten Schlammtrocknung und Konvertierung. Ziel des Aicher-Schlamm-Recycling-Verfahrens ist die Umwandlung der organischen Schlammfraktion in stofflich und energetisch verwertbare Oele. Bei der Umwandlung entsteht fixer Kohlenstoff, der im festen Rueckstand (Konversionskoks) angereichert wird. Neben dem gewonnenen Oel ist auch der produzierte Koks verwertbar. Einsatzstoffe fuer das Verfahren sind neben Klaerschlamm aus der kommunalen Abwasserreinigung vor allem industrielle Schlaemme mit hohen organischen Anteilen z.B. Schlaemme und Klaerschlaemme aus der Erdoelverarbeitung. (orig.)

  11. Damages on pumps and systems the handbook for the operation of centrifugal pumps

    CERN Document Server

    Merkle, Thomas

    2014-01-01

    Damage on Pumps and Systems. The Handbook for the Operation of Centrifugal Pumps offers a combination of the theoretical basics and practical experience for the operation of circulation pumps in the engineering industry. Centrifugal pumps and systems are extremely vulnerable to damage from a variety of causes, but the resulting breakdown can be prevented by ensuring that these pumps and systems are operated properly. This book provides a total overview of operating centrifugal pumps, including condition monitoring, preventive maintenance, life cycle costs, energy savings and economic aspects. Extra emphasis is given to the potential damage to these pumps and systems, and what can be done to prevent breakdown. Addresses specific issues about pumping of metal chips, sand, abrasive dust and other solids in fluidsEmphasis on economic and efficiency aspects of predictive maintenance and condition monitoring Uses life cycle costs (LCC) to evaluate and calculate the costs of pumping systems

  12. An economic evaluation comparison of solar water pumping system with engine pumping system for rice cultivation

    Science.gov (United States)

    Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn

    2015-08-01

    In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.

  13. Threshold pump power of a solar-pumped dye laser

    Science.gov (United States)

    Lee, Ja H.; Kim, Kyung C.; Kim, Kyong H.

    1988-01-01

    Threshold solar power for dye laser pumping has been determined by measuring the gain of a rhodamine 6G dye laser amplifier at various solar-simulated irradiances on an amplifier cell. The measured threshold was 20,000 solar constants (2.7 kW/sq cm) for the dye volume of 2 x 5 x 40 cu mm and the optimum dye concentration of 0.001 M. The threshold is about one-third of that achievable with a high-intensity solar concentrator.

  14. High efficiency, variable geometry, centrifugal cryogenic pump

    International Nuclear Information System (INIS)

    Forsha, M.D.; Nichols, K.E.; Beale, C.A.

    1994-01-01

    A centrifugal cryogenic pump has been developed which has a basic design that is rugged and reliable with variable speed and variable geometry features that achieve high pump efficiency over a wide range of head-flow conditions. The pump uses a sealless design and rolling element bearings to achieve high reliability and the ruggedness to withstand liquid-vapor slugging. The pump can meet a wide range of variable head, off-design flow requirements and maintain design point efficiency by adjusting the pump speed. The pump also has features that allow the impeller and diffuser blade heights to be adjusted. The adjustable height blades were intended to enhance the pump efficiency when it is operating at constant head, off-design flow rates. For small pumps, the adjustable height blades are not recommended. For larger pumps, they could provide off-design efficiency improvements. This pump was developed for supercritical helium service, but the design is well suited to any cryogenic application where high efficiency is required over a wide range of head-flow conditions

  15. Reactor coolant pumps for nuclear reactors

    International Nuclear Information System (INIS)

    Harand, E.; Richter, G.; Tschoepel, G.

    1975-01-01

    A brake for the pump rotor of a main coolant pump or a shutoff member on the pump are provided in order to prevent excess speeds of the pump rotor. Such excess speeds may occur in PWR type reactors with water at a pressure below, e.g., 150 bars if there is leakage from a coolant line associated with the main coolant pump. As a brake, a centrifugal brake depending upon the pump speed or a brake ring arranged on the pump housing and acting on the pump rotor, which ring would be activated by pressure differentials in the pump, may be used. If the pressure differences between suction and pressure sockets are very small, a controlled hydraulic increase of the pressure force on the brake may also be provided. Furthermore, a turbine brake may be provided. A slide which is automatically movable in closing position along the pump rotor axis is used as a shutoff element. It is of cylindrical configuration and is arranged concentrically with the rotor axis. (DG) [de

  16. Residual heat removal pump retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; McKenna, J.M.

    1990-01-01

    Residual Heat Removal (RHR) pumps installed in pressurized water reactor power plants are used to provide the removal of decay heat from the reactor and to provide low head safety injection in the event of loss of coolant in the reactor coolant system. These pumps are subjected to rather severe temperature and pressure transients, therefore, the majority of pumps installed in the RHR service are vertical pumps with a single stage impeller. RHR pumps have traditionally been a significant maintenance item for many utilities. The close-coupled pump design requires disassembly of the casing cover from the lower pump casing while performing these routine maintenance tasks. The casing separation requires the loosening of numerous highly torqued studs. Once the casing is separated, the impeller is dropped from the motor shaft to allow removal of the mechanical seal and casing cover from the motor shaft. Galling of the impeller to the motor shaft is not uncommon. The RHR pump internals are radioactive and the separation of the pump casing to perform routine maintenance exposes the maintenance personnel to high radiation levels. The handling of the impeller also exposes the maintenance personnel to high radiation levels. This paper introduces a design modification developed to convert the close-coupled RHR pumps to a coupled configuration

  17. Integratives versus traditionelles Lernen aus Sicht der Studierenden [Integrative vs. Traditional Learning from the Student Perspective

    Directory of Open Access Journals (Sweden)

    Kadmon, Guni

    2011-05-01

    CuMed beinhaltet interaktive, fallbasierte Kleingruppenseminare, Fertigkeiten- und Kommunikationstraining, Problem-orientiertes Lernen, studentische Fallbearbeitungen und -prĂ€sentationen sowie Unterricht am Krankenbett. Die Dozenten werden didaktisch geschult. Das vorangegangene traditionelle Curriculum basierte dagegen auf Vorlesungen und lediglich zwei Wochenstunden praktischen Unterrichts am Krankenbett. Ziel: Die vorliegende Arbeit analysiert den Beitrag didaktischer Merkmale des traditionellen und Reformcurriculums sowie der aktiven Mitarbeit der Studierenden zum Lernerfolg aus Sicht der Studierenden. Methode: Differenzierte studentische Evaluationen der chirurgischen Lehrveranstaltungen zwischen 1999 and 2008 wurden mittels Korrelations- und Regressionsanalysen untersucht.Ergebnisse: Das Engagement der Dozenten, ihre FĂ€higkeit, Interesse zu wecken und Kompliziertes verstĂ€ndlich zu erklĂ€ren, der Beitrag des Unterrichts zum Lernzuwachs, die UnterrichtsqualitĂ€t und besonders die geförderte Mitarbeit wurden in HeiCuMed signifikant besser bewertet als im traditionellen Curriculum. Die AbhĂ€ngigkeit des subjektiven Lernzuwachses von der didaktischen QualitĂ€t war hingegen in beiden Curricula gleich. Die geförderte studentische Mitarbeit erwies sich als wichtig fĂŒr den subjektiven Lernzuwachs in den Seminaren und Praktika von HeiCuMed und fĂŒr die evaluierte QualitĂ€t der Praktika aber nicht fĂŒr den Lernzuwachs im traditionellen Curriculum. Schlussfolgerung: Die Ergebnisse stehen im Einklang mit psychologisch-pĂ€dagogischen Erkenntnissen, dass integrative Lehrmethoden mehr zum Lehr- und Lernerfolg beitragen als der passive Wissenstransfer durch die traditionelle Vorlesung, und belegen die wichtige Bedeutung der didaktischen Kompetenz fĂŒr den Lehrerfolg.

  18. Extrakorporale Stoßwellentherapie (ESWT aus orthopĂ€discher und traumatologischer Sicht

    Directory of Open Access Journals (Sweden)

    Auersperg V

    2004-01-01

    Full Text Available Die ESWT ist eine derzeit sehr intensiv erforschte Therapieform und im Vergleich mit anderen Therapien auch durchaus hohen EBM-Kriterien entsprechend. Die Wirkungsweise der ESWT ist bis heute nicht ganz geklĂ€rt, aus den bisher durchgefĂŒhrten Untersuchungen (meist Tierversuche lassen sich folgende Wirkungen unterscheiden: ● Zerreißungen (Steindesintegration, Knochenfissuren, Gewebszerreißung ● Kavitation (mit Bildung von Jet streams und freien Radikalen ● Thermische und chemische Effekte ● Molekularbiologische und zellulĂ€re VerĂ€nderungen ● Hyperstimulationsanalgesie (gate-control-Mechanismus Diese Wirkungen rufen sehr komplexe VerĂ€nderungen im Gewebe hervor, die beispielsweise zur Knochenneubildung fĂŒhren, aber auch Neoangiogenese und NervenverĂ€nderungen, die beim VerstĂ€ndnis der Effekte der ESWT an den Weichteil-Indikationen durchaus auch ErklĂ€rungshilfen sind. Die meisten, bisher veröffentlichten, klinischen Studien haben biometrische MĂ€ngel und ihre Ergebnisse sind sehr kontrovers. Die angefĂŒhrten Indikationen sind die am meisten erforschten und sollen hier bewertet werden. Da fĂŒr weitere Indikationen die Studien-Daten so spĂ€rlich sind, werden sie hier nicht diskutiert. Die Indikationen mit statistisch signifikant guten Behandlungsergebnissen sind: ● Die Tendinitis calcarea (mit niedrigenergetischer und hochenergetischer ESWT ● Die Fasciitis plantaris mit und ohne plantarem Fersensporn (mit niedrigenergetischer und hochenergetischer ESWT ● Die Epicondylitis humeri lateralis (mit niedrigenergetischer und hochenergetischer ESWT ● Verzögerte Knochenbruchheilung (mit hochenergetischer ESWT ● Pseudoarthrosen (mit hochenergetischer ESWT FĂŒr die DurchfĂŒhrung, die Anzahl der Impulse und die IntervallĂ€nge zwischen den ESWT-Sitzungen lĂ€ĂŸt sich keine Regel ableiten, dies wird sich vernĂŒnftigerweise hauptsĂ€chlich an den lokalen Gegebenheiten orientieren. Die bisher (als Richtlinie der ISMST von 2000 → http

  19. Risk energy transition. Ways out of the impasse; Risiko Energiewende. Wege aus der Sackgasse

    Energy Technology Data Exchange (ETDEWEB)

    Kleinknecht, Konrad [Muenchen Univ., Garching (Germany). Fakultaet fuer Physik

    2015-07-01

    The exit of the use of nuclear energy in Germany, it was decided in the summer of 2011 in a rush. Now it is becoming obvious that there is no realistic plan for the conversion of energy supply in the envisaged deadline of ten years. For the conversion of our entire power supply and therefore our economy the period is too short. It lacks a robust empirical reason that have to deal with the issues of security of supply, the affordability, the impact on economic development and social justice. Thus, this treansition threatens to fail at their contradictions. Konrad Kleinknecht tries in his book, to name the problems and to find answers. For him, arise the following questions: What are our opportunity to replace with wind and solar power to replace a part of the power supply? What power sources provide secured capacity? Can we dispense with coal-fired plants? Do we need new power lines? How power may be stored? How real is the risk of blackouts in windless nights? Will the power prices continue to rise? Can be avoided the major risks of the energy transition with a fundamental reform of the Renewable Energies Act (EEG)? The power supply must serve the common good and benefit the industrial site Germany. A blackout would be a disaster for the whole country, it must be avoided at all events. How can we manage this, the author present in his evocative book. [German] Der Ausstieg aus der Nutzung der Kernenergie in Deutschland wurde im Sommer 2011 im Eiltempo beschlossen. Jetzt zeigt sich, dass es keinen realistischen Plan fuer den Umbau der Energieversorgung in der vorgesehenen Frist von zehn Jahren gibt. Fuer die Umstellung unserer gesamten Stromversorgung und damit unserer Wirtschaft ist der Zeitraum zu kurz. Es fehlt eine belastbare empirische Begruendung, die Fragen der Versorgungssicherheit, der Finanzierbarkeit, der Auswirkungen auf die wirtschaftliche Entwicklung und die soziale Gerechtigkeit behandeln muesste. Somit droht diese Wende an ihren Widerspruechen zu

  20. LOX/LH2 vane pump for auxiliary propulsion systems

    Science.gov (United States)

    Hemminger, J. A.; Ulbricht, T. E.

    1985-01-01

    Positive displacement pumps offer potential efficiency advantages over centrifugal pumps for future low thrust space missions. Low flow rate applications, such as space station auxiliary propulsion or dedicated low thrust orbiter transfer vehicles, are typical of missions where low flow and high head rise challenge centrifugal pumps. The positive displacement vane pump for pumping of LOX and LH2 is investigated. This effort has included: (1) a testing program in which pump performance was investigated for differing pump clearances and for differing pump materials while pumping LN2, LOX, and LH2; and (2) an analysis effort, in which a comprehensive pump performance analysis computer code was developed and exercised. An overview of the theoretical framework of the performance analysis computer code is presented, along with a summary of analysis results. Experimental results are presented for pump operating in liquid nitrogen. Included are data on the effects on pump performance of pump clearance, speed, and pressure rise. Pump suction performance is also presented.

  1. Effect of Non-linear Velocity Loss Changes in Pumping Stage of Hydraulic Ram Pumps on Pumping Discharge Rate

    Directory of Open Access Journals (Sweden)

    Reza Fatahialkouhi

    2018-03-01

    Full Text Available The ram pump is a device which pumps a portion of input discharge to the pumping system in a significant height by using renewable energy of water hammer. The complexities of flow hydraulic on one hand and on the other hand the use of simplifying assumptions in ram pumps have caused errors in submitted analytical models for analyzing running cycle of these pumps. In this study it has been tried to modify the governing analytical model on hydraulic performance of these pumps in pumping stage. In this study by creating a logical division, the cycle of the ram pump was divided into three stages of acceleration, pumping and recoil and the governing equations on each stage of cycling are presented by using method of characteristics. Since the closing of impulse valve is nonlinear, velocity loss in pumping stage is considered nonlinearly. Also the governing equations in pumping stage were modified by considering disc elasticity of impulse valve and changing volume of the pump body when the water hammer phenomenon is occurred. In order to evaluate results and determine empirical factors of the proposed analytical model, a physical model of the ram pump is made with internal diameter of 51 mm. Results of this study are divided into several parts. In the first part, loss coefficients of the impulse valve were measured experimentally and empirical equations of drag coefficient and friction coefficient of the impulse valve were submitted by using nonlinear regression. In the second part, results were evaluated by using experimental data taken from this study. Evaluation of statistical error functions showed that the proposed model has good accuracy for predicting experimental observations. In the third part, in order to validate the results in pumping stage, the analytical models of Lansford and Dugan (1941 and Tacke (1988 were used and the error functions resulted from prediction of experimental observations were investigated through analytical models of

  2. An experimental study on pump clogging

    International Nuclear Information System (INIS)

    Isono, M; Nohmi, M; Uchida, H; Kawai, M; Kudo, H; Kawahara, T; Miyagawa, K; Saito, S

    2014-01-01

    For sewage pump that various foreign substance is flowed into, anti-clogging performance is a factor as important as pump efficiency in order to avoid clogging trouble by foreign substance. Many investigations about pump inner flow and pump efficiency estimation have been carried out conventionally in order to realize coexistence with anti-clogging performance and pump performance. And these results have been reflected in construction of the running water section design method. As a index of anti-clogging performance, ''impeller passage diameter'' which is diameter of spherical solid that can pass through the pump is used widely. And there are various type of the sewage pump which have large impeller passage diameter. However real cause of clog is not a solid, and it is fibrous material such as towel and clothes, vinyl and paper diaper. In most case these material accumulate in the pump, so that clog is occurred. In this study, for the purpose of quantification of anti-clogging performance against fibrous materials, the factor that affect to clogging of pump was investigated by pump model test using a string. The test is done based on Taguchi method. In this test, type of the pump model, diameter of the string, material of the string, length of the string and flow rate are selected for the factor, and the effect that they have on the clogging of the pump was investigated. As a result of this test, it was made clear that length of the string has a strong influence on the clogging of the pump. And from the result of this test, evaluation method of anti-clogging performance of the pump against fibrous material by using string was considered. According to the result of above test based on Taguchi method, it was assumed that quantification of anti-clogging performance against fibrous materials is possible by flowing plural strings into the pump and calculating the probability of passing. Plurality sewage pumps of different types were evaluated based

  3. Heavy water pumps; Pumpe D{sub 2}O

    Energy Technology Data Exchange (ETDEWEB)

    Zecevic, V; Nikolic, M

    1963-12-15

    Continuous increase of radiation intensity was observed on all the elements in the heavy water system during first three years of RA reactor operation. The analysis of heavy water has shown the existence of radioactive cobalt. It was found that cobalt comes from stellite, cobalt based alloy which was used for coating of the heavy water pump discs in order to increase resistance to wearing. Cobalt was removed from the surfaces due to friction, and transferred by heavy water into the reactor where it has been irradiated for 29 876 MWh up to 8-15 Ci/g. Radioactive cobalt contaminated all the surfaces of aluminium and stainless steel parts. This report includes detailed description of heavy water pumps repair, exchange of stellite coated parts, decontamination of the heavy water system, distillation of heavy water. [Serbo-Croat] U toku prve tri godine eksploatacije reaktora RA uocen je neprekidni porast intenziteta zracenja na svim elementima u teskovodnom sistemu. Analizom teske vode utvrdjeno je postojanje radioaktivnog kobalta. Ustanovljeno je da kobalt potice od stelita, legure na bazi kobalta kojim su presvuceni rukavci vratila teskovodnih pumpi radi otpornosi na habanje. Kobalt je trenjem skidan sa povrsina, u toku rada prenosen je teskom vodom u reaktor i ozracivan u toku 29 876 MWh do specificne aktivnosti 8-15 Ci/g. Radioaktivni kobalt je kontaminirao sve povrsine od aluminijuma i nerdjajuceg celika. Ovaj izvestaj sadrzi detaljan opis remonta pumpi, zamene delova teskovodnih pumpi novim delovima bez stelitnog sloja, dekontaminacije teskovodnog sistema, destilacije teske vode.

  4. Submersible canned motor transfer pump

    International Nuclear Information System (INIS)

    Guardiani, R.F.; Pollick, R.D.; Nyilas, C.P.; Denmeade, T.J.

    1997-01-01

    A transfer pump is described which is used in a waste tank for transferring high-level radioactive liquid waste from a waste tank and having a column assembly, a canned electric motor means, and an impeller assembly with an upper impeller and a lower impeller connected to a shaft of a rotor assembly. The column assembly locates a motor housing with the electric motor means adjacent to the impeller assembly which creates an hydraulic head, and which forces the liquid waste, into the motor housing to cool the electric motor means and to cool and/or lubricate the radial and thrust bearing assemblies. Hard-on-hard bearing surfaces of the bearing assemblies and a ring assembly between the upper impeller and electric motor means grind large particles in the liquid waste flow. Slots in the static bearing member of the radial bearing assemblies further grind down the solid waste particles so that only particles smaller than the clearances in the system can pass there through, thereby resisting damage to and the interruption of the operation of the transfer pump. The column assembly is modular so that sections can be easily assembled, disassembled and/or removed. A second embodiment employs a stator jacket which provides an alternate means for cooling the electric motor means and lubricating and/or cooling the bearing assemblies, and a third embodiment employs a variable level suction device which allows liquid waste to be drawn into the transfer pump from varying and discrete levels in the waste tank. 17 figs

  5. User friendliness, efficiency & spray quality of stirrup pumps versus hand compression pumps for indoor residual spraying.

    Science.gov (United States)

    Kumar, Vijay; Kesari, Shreekant; Chowdhury, Rajib; Kumar, Sanjiv; Sinha, Gunjan; Hussain, Saddam; Huda, M Mamun; Kroeger, Axel; Das, Pradeep

    2013-01-01

    Indoor residual spraying (IRS) is a proven tool to reduce visceral leishmaniasis vectors in endemic villages. In India IRS is being done with stirrup pumps, whereas Nepal, Bangladesh, and other countries use compression pumps. The present study was conducted with the objectives to compare the efficiency, cost and user friendliness of stirrup and compression pumps. The study was carried out in Gorigawan village of the Vaishali district in north Bihar and included a total population of 3259 inhabitants in 605 households. Spraying with 50 per cent DDT was done by two teams with 6 persons per team under the supervision of investigators over 5 days with each type of pump (10 days in total using 2 stirrup pumps and 3 compression pumps) by the same sprayers in an alternate way. The spraying technique was observed using an observation check list, the number of houses and room surfaces sprayed was recorded and an interview with sprayers on their satisfaction with the two types of pumps was conducted. On average, 65 houses were covered per day with the compression pump and 56 houses were covered with the stirrup pump. The surface area sprayed per squad per day was higher for the compression pump (4636 mÂČ) than for the stirrup pump (4102 mÂČ). Observation showed that it was easy to maintain the spray swath with the compression pump but very difficult with the stirrup pump. The wastage of insecticide suspension was negligible for the compression pump but high for the stirrup pump. The compression pump was found to be more user friendly due to its lower weight, easier to operate, lower operation cost, higher safety and better efficiency in terms of discharge rate and higher area coverage than the stirrup pump.

  6. Rotary piston blood pumps: past developments and future potential of a unique pump type.

    Science.gov (United States)

    Wappenschmidt, Johannes; Autschbach, RĂŒdiger; Steinseifer, Ulrich; Schmitz-Rode, Thomas; Margreiter, Raimund; Klima, GĂŒnter; Goetzenich, Andreas

    2016-08-01

    The design of implantable blood pumps is either based on displacement pumps with membranes or rotary pumps. Both pump types have limitations to meet the clinical requirements. Rotary piston blood pumps have the potential to overcome these limitations and to merge the benefits. Compared to membrane pumps, they are smaller and with no need for wear-affected membranes and valves. Compared to rotary pumps, the blood flow is pulsatile instead of a non-physiological continuous flow. Furthermore, the risk of flow-induced blood damage and platelet activation may be reduced due to low shear stress to the blood. The past developments of rotary piston blood pumps are summarized and the main problem for long-term application is identified: insufficient seals. A new approach with seal-less drives is proposed and current research on a simplified rotary piston design is presented. Expert commentary: The development of blood pumps focuses mainly on the improvement of rotary pumps. However, medical complications indicate that inherent limitations of this pump type remain and restrict the next substantial step forward in the therapy of heart failure patients. Thus, research on different pump types is reasonable. If the development of reliable drives and bearings succeeds, rotary piston blood pumps become a promising alternative.

  7. Development of model pump for establishing hydraulic design of primary sodium pumps in PFBR

    International Nuclear Information System (INIS)

    Chougule, R.J.; Sahasrabudhe, H.G.; Rao, A.S.L.K.; Balchander, K.; Kale, R.D.

    1994-01-01

    Indira Gandhi Centre for Atomic Research, Kalpakkam indicated requirement of indigenous development of primary sodium pump, handling liquid sodium as coolant in Fast Breeder Reactor. The primary sodium pump concept selected in its preliminary design is a vertical, single stage, with single suction impeller, suction facing downwards. The pump is having diffuser, discharge casing and discharge collector. The 1/3 rd size model pump is developed to establish the hydraulic performance of the prototype primary sodium pump. The main objectives were to verify the hydraulic design to operate on low net positive suction head available (NPSHA), no evidence of visible cavitation at available NPSHA, the pump should be designed with a diffuser etc. The model pump PSP 250/40 was designed and successfully developed by Research and Development Division of M/s Kirloskar Brothers Ltd., Kirloskarvadi. The performance testing using model pump was successfully carried out on a closed circuit test rig. The performance of a model pump at three different speeds 1900 rpm, 1456 rpm and 975 rpm was established. The values of hydraulic axial thrust with and without balancing holes on impeller at 1900 rpm was measured. Visual cavitation study at 1900 rpm was carried out to establish the NPSH at bubble free operation of the pump. The tested performance of the model pump is converted to the full scale prototype pump. The predicted performance of prototype pump at 700 rpm was found to be meeting fully with the expected duties. (author). 6 figs., 3 tabs

  8. Absorption-heat-pump system

    Science.gov (United States)

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  9. Carbon Dioxide Absorption Heat Pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    2002-01-01

    A carbon dioxide absorption heat pump cycle is disclosed using a high pressure stage and a super-critical cooling stage to provide a non-toxic system. Using carbon dioxide gas as the working fluid in the system, the present invention desorbs the CO2 from an absorbent and cools the gas in the super-critical state to deliver heat thereby. The cooled CO2 gas is then expanded thereby providing cooling and is returned to an absorber for further cycling. Strategic use of heat exchangers can increase the efficiency and performance of the system.

  10. Smart Grid enabled heat pumps

    DEFF Research Database (Denmark)

    Carmo, Carolina; Detlefsen, Nina; Nielsen, Mads Pagh

    2014-01-01

    The transition towards a 100 % fossil-free energy system, while achieving extreme penetration levels of intermittent wind and solar power in electricity generation, requires demand-side technologies that are smart (intermittency-friendly) and efficient. The integration of Smart Grid enabling...... with an empirical study in order to achieve a number of recommendations with respect to technology concepts and control strategies that would allow residential vapor-compression heat pumps to support large-scale integration of intermittent renewables. The analysis is based on data gathered over a period of up to 3...

  11. Forces on Centrifugal Pump Impellers

    OpenAIRE

    Jery, Belgacem; Brennen, Christopher E.; Caughey, Thomas K.; Acosta, Allan

    1985-01-01

    Forces are exerted on a centrifugal pump impeller, due to the asymmetry of the flow caused by the volute of diffuser, and to the motion of the center of the impeller whenever the shaft whirls. Recent work in the measurement of these forces as a function of the whirl speed to shaft speed ratio, and the influence of the volute, is reviewed. These forces may be decomposed into a steady force, a static stiffness matrix, a damping matrix and an inertia matrix. It is shown that for centrifugal p...

  12. Condition monitoring of main coolant pumps, Dhruva

    International Nuclear Information System (INIS)

    Prasad, V.; Satheesh, C.; Acharya, V.N.; Tikku, A.C.; Mishra, S.K.

    2002-01-01

    Full text: Dhruva is a 100 MW research reactor with natural uranium fuel, heavy water as moderator and primary coolant. Three Centrifugal pumps circulate the primary coolant across the core and the heat exchangers. Each pump is coupled to a flywheel (FW) assembly in order to meet operational safety requirements. All the 3 main coolant pump (MCP) sets are required to operate during operation of the reactor. The pump-sets are in operation since the year 1984 and have logged more than 1,00,000 hrs. Frequent breakdowns of its FW bearings were experienced during initial years of operation. Condition monitoring of these pumps, largely on vibration based parameters, was initiated on regular basis. Break-downs of main coolant pumps reduced considerably due to the fair accurate predictions of incipient break-downs and timely maintenance efforts. An effort is made in this paper to share the experience

  13. Walking beam pumping unit system efficiency measurements

    International Nuclear Information System (INIS)

    Kilgore, J.J.; Tripp, H.A.; Hunt, C.L. Jr.

    1991-01-01

    The cost of electricity used by walking beam pumping units is a major expense in producing crude oil. However, only very limited information is available on the efficiency of beam pumping systems and less is known about the efficiency of the various components of the pumping units. This paper presents and discusses measurements that have been made on wells at several Shell locations and on a specially designed walking beam pump test stand at Lufkin Industries. These measurements were made in order to determine the overall system efficiency and efficiency of individual components. The results of this work show that the overall beam pumping system efficiency is normally between 48 and 58 percent. This is primarily dependent on the motor size, motor type, gearbox size, system's age, production, pump size, tubing size, and rod sizes

  14. Hydrostatic radial bearing of centrifugal pump

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    A hydrostatic radial pump is described characterized by the fact that part of the medium off-taken from delivery is used as a lubricating medium. Two additional bodies are placed alongside a hydrostatic bearing with coils in between them and the pump shaft; the coils have an opposite pitch. The feed channel for the hydrostatic bearing pocket is linked to delivery. The coil outlets are connected to the pump suction unit. Two rotating coils placed alongside the hydrostatic bearing will considerably simplify the communication channel design and reduce the dependence on the pump shaft deflections. The addition of another rotating coil in the close vicinity of the pump shaft or directly on the shaft further increases the efficiency. The bearing can be used in designing vertical circulating pumps for the cooling circuits of nuclear reactors. (J.B.)

  15. Geothermal heat pumps - Trends and comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Lund, John W

    1989-01-01

    Heat pumps are used where geothermal water or ground temperatures are only slightly above normal, generally 50 to 90 deg. F. Conventional geothermal heating (and cooling) systems are not economically efficient at these temperatures. Heat pumps, at these temperatures, can provide space heating and cooling, and with a desuperheater, domestic hot water. Two basic heat pump systems are available, air-source and water- or ground-source. Water- and ground-coupled heat pumps, referred to as geothermal heat pumps (GHP), have several advantages over air-source heat pumps. These are: (1) they consume about 33% less annual energy, (2) they tap the earth or groundwater, a more stable energy source than air, (3) they do not require supplemental heat during extreme high or low outside temperatures, (4) they use less refrigerant (freon), and (5) they have a simpler design and consequently less maintenance.

  16. Compact, Lightweight Electromagnetic Pump for Liquid Metal

    Science.gov (United States)

    Godfroy, Thomas; Palzin, Kurt

    2010-01-01

    A proposed direct-current electromagnetic pump for circulating a molten alkali metal alloy would be smaller and lighter and would demand less input power, relative to currently available pumps of this type. (Molten alkali metals are used as heat-transfer fluids in high-temperature stages of some nuclear reactors.) The principle of operation of this or any such pump involves exploitation of the electrical conductivity of the molten metal: An electric current is made to pass through the liquid metal along an axis perpendicular to the longitudinal axis of the flow channel, and a magnetic field perpendicular to both the longitudinal axis and the electric current is superimposed on the flowchannel region containing the electric current. The interaction between the electric current and the magnetic field produces the pumping force along the longitudinal axis. The advantages of the proposed pump over other such pumps would accrue from design features that address overlapping thermal and magnetic issues.

  17. Knudsen pump driven by a thermoelectric material

    International Nuclear Information System (INIS)

    Pharas, Kunal; McNamara, Shamus

    2010-01-01

    The first use of a thermoelectric material in the bidirectional operation of a gas pump using thermal transpiration has been demonstrated. The thermoelectric material maintains a higher temperature difference which favors thermal transpiration and thus increases the efficiency of gas pumping. Since the hot and cold sides of the thermoelectric material are reversible, the direction of the pump may be changed by reversing the electrical current direction. Two different pump designs are presented that illustrate some of the design tradeoffs. The pumps are characterized by measuring the pressure difference that may be generated and by measuring the flow rate in the forward and reverse directions. For a pump composed of a porous material with a pore size of 100 nm, a maximum flow rate of 0.74 cm 3 min −1 and a maximum pressure of 1.69 kPa are achieved

  18. Feasibility of solar-pumped dye lasers

    Science.gov (United States)

    Lee, Ja H.; Kim, Kyung C.; Kim, Kyong H.

    1987-01-01

    Dye laser gains were measured at various pump-beam irradiances on a dye cell in order to evaluate the feasibility of solar pumping. Rhodamine 6G dye was considered as a candidate for the solar-pumped laser because of its high utilization of the solar spectrum and high quantum efficiency. Measurements show that a solar concentration of 20,000 is required to reach the threshold of the dye.

  19. Solar PV energy for water pumping system

    International Nuclear Information System (INIS)

    Mahar, F.

    1997-01-01

    The paper provides an introduction into understanding the relative merits, characteristics, including economics, of photovoltically powered water pumping systems. Although more than 10,000 photovoltaic pumping systems are known to be operating through out the world, many potential users do not know how to decide weather feasibility assessment, and system procurement so that the reader can made an informed decision about water pumping systems, especially those powered with photovoltaics. (author)

  20. 46 CFR 109.329 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 109.329 Section 109.329 Shipping COAST GUARD... of Safety Equipment § 109.329 Fire pumps. The master or person in charge shall insure that at least one of the fire pumps required in § 108.415 is ready for use on the fire main system at all times. ...

  1. Pumped Storage and Potential Hydropower from Conduits

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-02-25

    Th is Congressional Report, Pumped Storage Hydropower and Potential Hydropower from Conduits, addresses the technical flexibility that existing pumped storage facilities can provide to support intermittent renewable energy generation. This study considered potential upgrades or retrofit of these facilities, the technical potential of existing and new pumped storage facilities to provide grid reliability benefits, and the range of conduit hydropower opportunities available in the United States.

  2. Absorption heat pump for space applications

    Science.gov (United States)

    Nguyen, Tuan; Simon, William E.; Warrier, Gopinath R.; Woramontri, Woranun

    1993-01-01

    In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.

  3. Development of submersible axial pump for wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jeong Eui [Kangwon Nat' l Univ., Chuncheon (Korea, Republic of)

    2013-02-15

    This study was performed to develop a high efficiency submersible axial pump for concentration wastewater treatment. To do this, we simulated the effect of some parameters such as the axial twist angle of a blade({beta}), the radial twist angle of a blade({alpha}) and the length of a blade ({iota}) on pump efficiency using commercial code, ANSYS CFX and BladeGen. The results showed that the axial twist angle of a blade({beta}) was the most sensible parameter on the pump efficiency. And the pump efficiency had a maximum at {beta}=20.deg, {alpha}=110.deg and {iota}=240mm.

  4. Circulating water pumps for nuclear power stations

    International Nuclear Information System (INIS)

    Satoh, Hiroshi; Ohmori, Tsuneaki

    1979-01-01

    Shortly, the nuclear power station with unit power output of 1100 MW will begin the operation, and the circulating water pumps manufactured recently are those of 2.4 to 4 m bore, 840 to 2170 m 3 /min discharge and 2100 to 5100 kW driving power. The circulating water pumps are one of important auxiliary machines, because if they fail, power generation capacity lowers immediately. Enormous quantity of cooling water is required to cool condensers, therefore in Japan, sea water is usually used. As siphon is formed in circulating water pipes, the total head of the pumps is not very high. The discharge of the pumps is determined so as to keep the temperature rise of discharged water lower than 7 deg. C. The quantity of cooling water for nuclear power generation is about 50% more as compared with thermal power generation because of the difference in steam conditions. The total head of the pumps is normally from 8 to 15 m. The circulating water pumps rarely stop after they started the operation, therefore it is economical to determine the motor power so that it can withstand 10% overload for a short period, instead of large power. At present, vertical shaft, oblique flow circulating water pumps are usually employed. Recently, movable blade pumps are adopted. The installation, construction and materials of the pumps and the problems are described. (Kako, I.)

  5. Pump limiter studies in Tore Supra

    International Nuclear Information System (INIS)

    Chatelier, M.; Bonnel, P.; Bruneau, J.L.; Gil, C.; Grisolia, C.; Loarer, T.; Martin, G.; Pegourie, B.; Rodriguez, L.

    1991-01-01

    The aim of the Tore Supra pump limiter program is to study particle exhaust with a pump limiter system in long-pulse discharges with continuous pellet fueling and strong auxiliary heating. The pump limiter system consists of six vertical modules, located at the bottom of the machine, and one horizontal module at the outer midplane. The instrumentation of the limiter included pressure gauges, a residual gas analyser Langmuir probes, a spectrometer and water calorimeters. Initial results in low-density discharges, with the outboard limiter only, showed a modest effect on the plasma density, while large exhaust fluxes were measured in the pump limiter, without any external fueling

  6. Flow pumping system for physiological waveforms.

    Science.gov (United States)

    Tsai, William; SavaƟ, Omer

    2010-02-01

    A pulsatile flow pumping system is developed to replicate flow waveforms with reasonable accuracy for experiments simulating physiological blood flows at numerous points in the body. The system divides the task of flow waveform generation between two pumps: a gear pump generates the mean component and a piston pump generates the oscillatory component. The system is driven by two programmable servo controllers. The frequency response of the system is used to characterize its operation. The system has been successfully tested in vascular flow experiments where sinusoidal, carotid, and coronary flow waveforms are replicated.

  7. Development and evaluation of cryosorption pump and cryotrapping pump for CTR applications

    International Nuclear Information System (INIS)

    Kuribayashi, S.; Ota, H.; Sato, H.

    1986-01-01

    In order to obtain the engineering data to design compound cryopump for CTR, the authors tested the cryosorption pump and cryotrapping pump. The cryosorption panel was consisted of coconut charcoal metallically bonded to 4.2K cryopanel by brazing. The initial pumping speed of helium of cryosorption pump was found to be ≅2.2 iota/scm/sup 2/. The speed dropped off with loading (about 8 Torr iota/cm/sup 2/) to 1.5 iota/scm/sup 2/. The initial helium pumping speed of the 4.2K cryotrapping pump by argon spray was found to be ≅6 iota/scm/sup 2/. The speed, however, dropped off with loading (≅0.3 Torr iota/cm/sup 2/) to less than 5%. These results indicate that the cryosorption pump by coconut charcoal is superior to the cryotrapping pump, because the capacity of the former is larger than the latter

  8. Efficiency and threshold pump intensity of CW solar-pumped solid-state lasers

    Science.gov (United States)

    Hwang, In H.; Lee, Ja H.

    1991-01-01

    The authors consider the relation between the threshold pumping intensity, the material properties, the resonator parameters, and the ultimate slope efficiencies of various solid-state laser materials for solar pumping. They clarify the relation between the threshold pump intensity and the material parameters and the relation between the ultimate slope efficiency and the laser resonator parameters such that a design criterion for the solar-pumped solid-state laser can be established. Among the laser materials evaluated, alexandrite has the highest slope efficiency of about 12.6 percent; however, it does not seem to be practical for a solar-pumped laser application because of its high threshold pump intensity. Cr:Nd:GSGG is the most promising for solar-pumped lasing. Its threshold pump intensity is about 100 air-mass-zero (AM0) solar constants and its slope efficiency is about 12 percent when thermal deformation is completely prevented.

  9. A regenerative elastocaloric heat pump

    Science.gov (United States)

    TuĆĄek, Jaka; Engelbrecht, Kurt; Eriksen, Dan; Dall'Olio, Stefano; TuĆĄek, Janez; Pryds, Nini

    2016-10-01

    A large fraction of global energy use is for refrigeration and air-conditioning, which could be decarbonized if efficient renewable energy technologies could be found. Vapour-compression technology remains the most widely used system to move heat up the temperature scale after more than 100 years; however, caloric-based technologies (those using the magnetocaloric, electrocaloric, barocaloric or elastocaloric effect) have recently shown a significant potential as alternatives to replace this technology due to high efficiency and the use of green solid-state refrigerants. Here, we report a regenerative elastocaloric heat pump that exhibits a temperature span of 15.3 K on the water side with a corresponding specific heating power up to 800 W kg-1 and maximum COP (coefficient-of-performance) values of up to 7. The efficiency and specific heating power of this device exceeds those of other devices based on caloric effects. These results open up the possibility of using the elastocaloric effect in various cooling and heat-pumping applications.

  10. Submersible canned motor mixer pump

    International Nuclear Information System (INIS)

    Guardiani, R.F.; Pollick, R.D.

    1997-01-01

    A mixer pump is described used in a waste tank for mobilizing high-level radioactive liquid waste having a column assembly containing power cables, a motor housing with electric motor means which includes a stator can of a stator assembly and a rotor can of a rotor assembly, and an impeller assembly with an impeller connected to a shaft of the rotor assembly. The column assembly locates the motor housing with the electric motor means adjacent to the impeller which creates an hydraulic head, and which forces the liquid waste into the motor housing to cool the electric motor means and to lubricate radial and thrust bearing assemblies. Hard-on-hard bearing surfaces of the bearing assemblies and a ring assembly between the impeller and electric motor means act to grind down large particles in the liquid waste flow. These larger particles are received in slots in the static bearing members of the radial bearing assemblies. Only solid waste particles smaller than the clearances in the system can pass there through, thereby resisting damage to and the interruption of the operation of the mixer pump. 10 figs

  11. Photoacoustic imaging of lymphatic pumping

    Science.gov (United States)

    Forbrich, Alex; Heinmiller, Andrew; Zemp, Roger J.

    2017-10-01

    The lymphatic system is responsible for fluid homeostasis and immune cell trafficking and has been implicated in several diseases, including obesity, diabetes, and cancer metastasis. Despite its importance, the lack of suitable in vivo imaging techniques has hampered our understanding of the lymphatic system. This is, in part, due to the limited contrast of lymphatic fluids and structures. Photoacoustic imaging, in combination with optically absorbing dyes or nanoparticles, has great potential for noninvasively visualizing the lymphatic vessels deep in tissues. Multispectral photoacoustic imaging is capable of separating the components; however, the slow wavelength switching speed of most laser systems is inadequate for imaging lymphatic pumping without motion artifacts being introduced into the processed images. We investigate two approaches for visualizing lymphatic processes in vivo. First, single-wavelength differential photoacoustic imaging is used to visualize lymphatic pumping in the hindlimb of a mouse in real time. Second, a fast-switching multiwavelength photoacoustic imaging system was used to assess the propulsion profile of dyes through the lymphatics in real time. These approaches may have profound impacts in noninvasively characterizing and investigating the lymphatic system.

  12. HSB 84A pumping test

    Energy Technology Data Exchange (ETDEWEB)

    Maloney, W.

    2000-03-06

    Two constant discharge, multiple well pumping tests were performed in the Congaree aquifer at the H-Area seepage basins during the weeks of April 30 through May 11. The purpose of the tests was to collect information that might determine the source of groundwater contamination in the Congaree aquifer and to estimate the hydraulic parameters of the aquifer. Transmissivity estimates from data collected in Test One ranged from 1,644 ft{sup 2}/day to 2,253 ft{sup 2}/day with an average of 2,013 ft{sup 2}/day and from 1,812 ft{sup 2}/day to 2,562 ft{sup 2}/day with an average of 2,269 ft{sup 2}/day in Test Two. Some leakage through the confining bed was apparent in the vicinity of observation well HSB 69A. This report includes the data collected, the analyses, results and interpretation of the pumping tests performed at HSB 84A. It should serve as a good baseline for future studies on the subject of contaminant migration in the Congaree aquifer on the Savannah River Site.

  13. Mathematical modeling of reciprocating pump

    International Nuclear Information System (INIS)

    Lee, Jong Kyeom; Jung, Jun Ki; Chai, Jang Bom; Lee, Jin Woo

    2015-01-01

    A new mathematical model is presented for the analysis and diagnosis of a high-pressure reciprocating pump system with three cylinders. The kinematic and hydrodynamic behaviors of the pump system are represented by the piston displacements, volume flow rates and pressures in its components, which are expressed as functions of the crankshaft angle. The flow interaction among the three cylinders, which was overlooked in the previous models, is considered in this model and its effect on the cylinder pressure profiles is investigated. The tuning parameters in the mathematical model are selected, and their values are adjusted to match the simulated and measured cylinder pressure profiles in each cylinder in a normal state. The damage parameter is selected in an abnormal state, and its value is adjusted to match the simulated and ensured pressure profiles under the condition of leakage in a valve. The value of the damage parameter over 300 cycles is calculated, and its probability density function is obtained for diagnosis and prognosis on the basis of the probabilistic feature of valve leakage.

  14. Proton pump inhibitors and osteoporosis

    DEFF Research Database (Denmark)

    Andersen, Bjarne Nesgaard; Johansen, Per Birger; Abrahamsen, Bo

    2016-01-01

    PURPOSE OF REVIEW: The purpose of the review is to provide an update on recent advances in the evidence based on proton pump inhibitors (PPI) as a possible cause of osteoporosis and osteoporotic fractures. This review focuses, in particular, on new studies published in the last 18 months and a di......PURPOSE OF REVIEW: The purpose of the review is to provide an update on recent advances in the evidence based on proton pump inhibitors (PPI) as a possible cause of osteoporosis and osteoporotic fractures. This review focuses, in particular, on new studies published in the last 18 months...... and a discussion of these findings and how this has influenced our understanding of this association, the clinical impact and the underlying pathophysiology. RECENT FINDINGS: New studies have further strengthened existing evidence linking use of PPIs to osteoporosis. Short-term use does not appear to pose a lower...... risk than long-term use. There is a continued lack of conclusive studies identifying the pathogenesis. Direct effects on calcium absorption or on osteoblast or osteoclast action cannot at present plausibly explain the mechanism. SUMMARY: The use of PPIs is a risk factor for development of osteoporosis...

  15. HSB 84A pumping test

    International Nuclear Information System (INIS)

    Maloney, W.

    2000-01-01

    Two constant discharge, multiple well pumping tests were performed in the Congaree aquifer at the H-Area seepage basins during the weeks of April 30 through May 11. The purpose of the tests was to collect information that might determine the source of groundwater contamination in the Congaree aquifer and to estimate the hydraulic parameters of the aquifer. Transmissivity estimates from data collected in Test One ranged from 1,644 ft 2 /day to 2,253 ft 2 /day with an average of 2,013 ft 2 /day and from 1,812 ft 2 /day to 2,562 ft 2 /day with an average of 2,269 ft 2 /day in Test Two. Some leakage through the confining bed was apparent in the vicinity of observation well HSB 69A. This report includes the data collected, the analyses, results and interpretation of the pumping tests performed at HSB 84A. It should serve as a good baseline for future studies on the subject of contaminant migration in the Congaree aquifer on the Savannah River Site

  16. Multi-stage internal gear/turbine fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Eugen; Raney, Michael Raymond

    2004-07-06

    A multi-stage internal gear/turbine fuel pump for a vehicle includes a housing having an inlet and an outlet and a motor disposed in the housing. The multi-stage internal gear/turbine fuel pump also includes a shaft extending axially and disposed in the housing. The multi-stage internal gear/turbine fuel pump further includes a plurality of pumping modules disposed axially along the shaft. One of the pumping modules is a turbine pumping module and another of the pumping modules is a gerotor pumping module for rotation by the motor to pump fuel from the inlet to the outlet.

  17. [Anja Wilhelmi, Menschenbilder aus Reval und St. Peterburg. ReiseeindrĂŒcke einer EnglĂ€nderin um 1840] / Paul Kaegbein

    Index Scriptorium Estoniae

    Kaegbein, Paul

    2006-01-01

    Arvustus: Anja Wilhelmi, Menschenbilder aus Reval und St. Peterburg. ReiseeindrĂŒcke einer EnglĂ€nderin um 1840. In: KollektivitĂ€t und IndividualitĂ€t. Hamburg: KovaĂš, 2001. S. 224-242. Elizabeth Rigby 1840. aastal Londonis anonĂŒĂŒmselt ilmunud raamatust "Letters from the shores of the Baltic"

  18. Amsterdam Expeditions to the West Indian Islands, Report 3. Eine neue Gattung der Familie Parabathynellidae (Bathynellacea, Syncarida) aus dem nördlichen SĂŒdamerika

    NARCIS (Netherlands)

    Schmincke, Horst Kurt

    1979-01-01

    Eine neue Gattung und Art der Familie Parabathynellidae, Psalidobathynella stocki gen. n., sp. n., wird beschrieben. Die Tiere stammen aus einer Quelle und einem Brunnen von der Halbinsel Paraguana in Venezuela. Es handelt sich um sehr urtĂŒmliche Parabathynellidae. Da MĂ€nnchen bisher nicht bekannt

  19. Diagnostic Thyroidectomy May Be Preferable in Patients With Suspicious Ultrasonography Features After Cytopathology Diagnosis of AUS/FLUS in the Bethesda System

    Science.gov (United States)

    Lee, Yong Sang; Kim, Hyeung Kyoo; Chang, Hojin; Kim, Seok Mo; Kim, Bup-Woo; Chang, Hang-Seok; Park, Cheong Soo

    2015-01-01

    Abstract Atypia/follicular lesion of undetermined significance (AUS/FLUS) is a new category in the Bethesda System for Reporting Thyroid Cytopathology (BSRTC) for which repeat fine-needle aspiration cytology (FNAC) is recommended. The aim of this study was to identify specific ultrasonography and clinical predictors of malignancy in a subset of thyroid nodules associated with cytology diagnoses of AUS/FLUS. Between January 2011 and December 2102, 5440 patients underwent thyroid surgery at our institution. Of these, 213 patients were diagnosed AUS/FLUS at the preoperative cytopathology diagnosis. The frequency of FNAC and ultrasonography images was compared between patients with cancerous and benign tumors based on their final pathology. Of the 213 patients, 158 (74.2%) were diagnosed with thyroid carcinoma in their final pathology reports. In univariate and multivariate analyses, the frequency of FNAC was not significantly correlated with the cancer diagnosis. Hypoechogenicity (odds ratio 2.521, P = 0.007) and microcalcification (odds ratio 3.247, P = 0.005) were statistically correlated with cancer risk. Although AUS/FLUS in cytopathology is recommended for repeating FNAC in BSRTC, we proposed that thyroid nodules with ultrasonography findings that suggest the possibility of cancer should undergo thyroidectomy with diagnostic intent. PMID:26705204

  20. Measurements on a PV solar pump equipped with a piston pump with a matching valve

    NARCIS (Netherlands)

    Smulders, P.T.; Ten Thije O.G. Boonkkamp, J.; Borg, van der N.J.C.M.; Beek, van M.

    1997-01-01

    The work on a simple high efficient solar pump equipped with a piston pump with a matching valve, reported at the Solar World Congress in Budapest, has been continued. Quasi-static and dynamic models of the solar pump have been derived with which the operation of the system is simulated. A test rig

  1. Early outcome of off-pump versus on-pump coronary revascularization

    African Journals Online (AJOL)

    Introduction: The use of coronary artery bypass surgery (CABG) with cardiopulmonary bypass (CPB) or without CPB technique (off-pump) can be associated with different mortality and morbidity and their outcomes remain uncertain. The goal of this study was to evaluate the early outcome of on-pump versus off-pump CABG.

  2. Root cause analysis of pump valve failures of three membrane pump systems

    NARCIS (Netherlands)

    Buijs, L.J.; Eijk, A.; Hooft, L. van

    2014-01-01

    This paper will present the root cause analysis and the solution of fatigue failures of the pump valves of three membrane pump systems installed on a chemical plant of Momentive in Pernis, the Netherlands. The membrane pumps were installed approximately 30 years ago. Each system has encountered

  3. Development of new design mechanical seal tester for Primary Loop Recirculation Pump (PLR Pump)

    International Nuclear Information System (INIS)

    Fukushima, Naoki; Koshiba, Koremutsu

    1995-01-01

    The mechanical seal for a Primary Loop Recirculation Pump (PLR Pump) is an important part of a BWR plant. This study describes a new mechanical seal tester developed to certify mechanical seal performance before installation in a PLR Pump on site. (author)

  4. Pump audit identifies the energy consumers; Pump Audit identifiziert gezielt die Energieverschwender

    Energy Technology Data Exchange (ETDEWEB)

    Siekemann, Ralf [Grundfos GmbH, Erkrath (Germany)

    2011-03-14

    Engineering and services, which enhance and secure the energy efficiency of pump systems, are demanded. Speed-regulated pumps, included high efficient motors and a service philosophy, be designed on value conservation and cost control, are as well as professional ''pump-audits''. (orig./GL)

  5. Pumping Optimization Model for Pump and Treat Systems - 15091

    Energy Technology Data Exchange (ETDEWEB)

    Baker, S.; Ivarson, Kristine A.; Karanovic, M.; Miller, Charles W.; Tonkin, M.

    2015-01-15

    Pump and Treat systems are being utilized to remediate contaminated groundwater in the Hanford 100 Areas adjacent to the Columbia River in Eastern Washington. Design of the systems was supported by a three-dimensional (3D) fate and transport model. This model provided sophisticated simulation capabilities but requires many hours to calculate results for each simulation considered. Many simulations are required to optimize system performance, so a two-dimensional (2D) model was created to reduce run time. The 2D model was developed as a equivalent-property version of the 3D model that derives boundary conditions and aquifer properties from the 3D model. It produces predictions that are very close to the 3D model predictions, allowing it to be used for comparative remedy analyses. Any potential system modifications identified by using the 2D version are verified for use by running the 3D model to confirm performance. The 2D model was incorporated into a comprehensive analysis system (the Pumping Optimization Model, POM) to simplify analysis of multiple simulations. It allows rapid turnaround by utilizing a graphical user interface that: 1 allows operators to create hypothetical scenarios for system operation, 2 feeds the input to the 2D fate and transport model, and 3 displays the scenario results to evaluate performance improvement. All of the above is accomplished within the user interface. Complex analyses can be completed within a few hours and multiple simulations can be compared side-by-side. The POM utilizes standard office computing equipment and established groundwater modeling software.

  6. MIRANDA - a module based on multiregion resonance theory for generating cross sections within the AUS neutronics code system

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1985-12-01

    MIRANDA is the cross-section generation module of the AUS neutronics code system used to prepare multigroup cross-section data which are pertinent to a particular study from a general purpose multigroup library of cross sections. Libraries have been prepared from ENDF/B which are suitable for thermal and fast fission reactors and for fusion blanket studies. The libraries include temperature dependent data, resonance cross sections represented by subgroup parameters and may contain photon as well as neutron data. The MIRANDA module includes a multiregion resonance calculation in slab, cylinder or cluster geometry, a homogeneous B L flux solution, and a group condensation facility. This report documents the modifications to an earlier version of MIRANDA and provides a complete user's manual

  7. Herausforderungen beim Aufbau und bei der Pflege einer Bilddatenbank – ein Anwendungsbeispiel aus dem Digitalen Forschungsarchiv Byzanz (DiFAB

    Directory of Open Access Journals (Sweden)

    Nina Rannharter

    2017-09-01

    Full Text Available Mit Metadaten versehene, digital archivierte Bilder sind aufgrund ihrer hohen KomplexitĂ€t eine stĂ€ndige Herausforderung fĂŒr den Aufbau von Metadatenstrukturen und fĂŒr das Beibehalten von adĂ€quaten Metadatenstandards in Bilddatenbanken. Besonders bei Bildern ĂŒber eine materielle Kultur zeichnet sich diese KomplexitĂ€t in den diversen Ebenen ab. Zur Verdeutlichung dieser Problematik dient ein einzelnes Monument mit seiner fotographischen Dokumentation als geisteswissenschaftliches Anwendungsbeispiel aus dem Digitalen Forschungsarchiv Byzanz (DiFAB der UniversitĂ€t Wien. Unter der grundsĂ€tzlichen BerĂŒcksichtigung der kĂŒnftigen Anforderungen und der einfachen Navigation von Metadaten beinhaltet dieser Beitrag u. a. die Herausforderungen mit den diversen analogen und digitalen Formen der Dokumentation, der historischen Geographie, der kulturspezifischen Terminologie sowie mit der kunsthistorischen Bedeutung einer exakten und unscharfen Datierung fĂŒr Forschungsarchive.

  8. 4. Meeting on cooling towers. From practice - for practice; 4. Kuehlturm-Tagung. Aus der Praxis - Fuer die Praxis

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    The 4th Cooling Tower meeting brought into focus aspects of economic efficiency of the water cooling system, i.e. the papers analyse investment cost and operating cost taking into account environmental policy and interests. Numerous examples from practice are discussed in the papers showing how wet cooling tower design and application-specific selection of design features can influence the performance of the entire system. (orig./CB) [Deutsch] Im Mittelpunkt der 4. Kuehlturm-Tagung steht die Wirtschaftlichkeit der Wasserrueckkuehlanlage, d.h. die Betrachtung der Investitions- und Betriebskosten unter Beruecksichtigung der Belange des Umweltschutzes. Mit Beispielen aus der Praxis zeigen die Referenten, wie sich die Auslegung und Auswahl eines Nasskuehlturms auf das Betriebsergebnis der Anlage auswirken. (orig./GL)

  9. Open Innovation neu denken und steuern: Ein Beitrag aus der Perspektive des Innovationsmanagements an der ETH-Bibliothek

    Directory of Open Access Journals (Sweden)

    Franziska Regner

    2015-11-01

    Full Text Available Der Artikel nennt und erlĂ€utert Grundlagen und exemplarische Felder, die sich aus Sicht des Innovationsmanagements an der ETH-Bibliothek anbieten, um Open Innovation zu implementieren und etablierte Methoden des Innovationsmanagements zu erweitern. The article outlines basic principles and exemplary fields concerning the implementation of Open Innovation in order to expand established methods in innovation management. The article is based on the perspective of innovation management at ETH-Bibliothek. Cet article esquisse les principes de base ainsi que des exemples de champs d’action permettant la mise en place d’une innovation ouverte (« open innovation ». La perspective se base sur la gestion de l’innovation Ă  la bibliothĂšque de l’École polytechnique fĂ©dĂ©rale de Zurich (ETH.

  10. Interkulturelle kommunikative Kompetenz – ein Versuch der Operationalisierung aus dem Fach Deutsch an der dĂ€nischen Lehrerausbildung

    DEFF Research Database (Denmark)

    Bjerre, Kirsten; Daryai-Hansen, Petra

    2017-01-01

    Mit diesem Artikel versuchen wir, den Begriff 'interkulturelle kommunikative Kompetenz‘ theoretisch zu entwickeln. Wir gehen zunĂ€chst der Frage nach, warum im Fach Deutsch als Fremdsprache mit interkultureller kommunikativer Kompetenz gearbeitet werden sollte und welche Herausforderungen sich...... hierbei stellen. Im Anschluss prĂ€sentieren wir unser Modell der interkulturellen kommunikativen Kompetenz, das wir fĂŒr das Fach Deutsch ain der dĂ€nischen Lehrerausbildung auf der Grundlage eines Modells von Michael Byram aus dem Jahre 1997 entwickelt haben. Byrams Modell der interkulturellen...... zunĂ€chst die Begriffe ‚Kompetenz‘, ‚Kultur‘, ‚kommunikative Kompetenz‘ und ‚interkulturelle Kompetenz‘. Wir konkretisieren die Dimensionen des Modells im Anschluss anhand eines Unterrichtsbeispiels fĂŒr das Fach Deutsch an der dĂ€nischen Einheitsschule („Folkeskole“). Abschließend skizzieren wir, wie unser...

  11. Features of rotary pump diagnostics without dismantling

    Directory of Open Access Journals (Sweden)

    Sergeev K. О.

    2017-12-01

    Full Text Available In ship power plants, rotor pumps have become very popular providing the transfer of various viscous fluids: fuels, oils, etc. Like all ship's mechanisms, pumps need proper maintenance and monitoring of technical condition. The most expedient is maintenance and repair carried out according to the results of dismantling diagnosis. The methods of vibrodiagnostics are mostly widespread for the diagnosis of pumps. Vibrodiagnosis of rotary pumps has a number of features due to the nature and condition of pumped fluids. The norms of the Russian Maritime Register of Shipping are used for setting standards of vibration and diagnostics of the rotary pumps' technical condition. To clarify the features of vibration diagnostics of rotary pumps some measurements have been made on a special bench that simulates various modes of ship's pumps' operation: different pressure in the system and temperature of the pumped medium. As a result of measurements one-third octave and narrow-band vibration spectra of pumps have been obtained at various developed pressures and temperatures of the pumped fluid. The performed analysis has shown that the RMRS norms for diagnostics of ship rotary pumps have insufficient informative value inasmuch they do not take into account the dependence of the vibrational signal spectrum on the developed pressure and temperature of the pumped fluid. The nature of the received signals shows that the levels of a third-octave spectrum of the vibration velocity depend significantly on the temperature of the pumped fluids, this fact must be taken into account when applying the RMRS norms. The fluid temperature has a great influence on the nature of the narrow-band vibration acceleration spectrum in the area of medium frequencies, less influence – on the nature of the vibration velocity spectrum. The conclusions have been drawn about the advisability of using the narrow-band vibration spectra and the envelope spectra of the high

  12. Miniature Scroll Pumps Fabricated by LIGA

    Science.gov (United States)

    Wiberg, Dean; Shcheglov, Kirill; White, Victor; Bae, Sam

    2009-01-01

    Miniature scroll pumps have been proposed as roughing pumps (low - vacuum pumps) for miniature scientific instruments (e.g., portable mass spectrometers and gas analyzers) that depend on vacuum. The larger scroll pumps used as roughing pumps in some older vacuum systems are fabricated by conventional machining. Typically, such an older scroll pump includes (1) an electric motor with an eccentric shaft to generate orbital motion of a scroll and (2) conventional bearings to restrict the orbital motion to a circle. The proposed miniature scroll pumps would differ from the prior, larger ones in both design and fabrication. A miniature scroll pump would include two scrolls: one mounted on a stationary baseplate and one on a flexure stage (see figure). An electromagnetic actuator in the form of two pairs of voice coils in a push-pull configuration would make the flexure stage move in the desired circular orbit. The capacitance between the scrolls would be monitored to provide position (gap) feedback to a control system that would adjust the drive signals applied to the voice coils to maintain the circular orbit as needed for precise sealing of the scrolls. To minimize power consumption and maximize precision of control, the flexure stage would be driven at the frequency of its mechanical resonance. The miniaturization of these pumps would entail both operational and manufacturing tolerances of pump components. In addition, the vibrations of conventional motors and ball bearings exceed these tight tolerances by an order of magnitude. Therefore, the proposed pumps would be fabricated by the microfabrication method known by the German acronym LIGA ( lithographie, galvanoformung, abformung, which means lithography, electroforming, molding) because LIGA has been shown to be capable of providing the required tolerances at large aspect ratios.

  13. Nonlinear Aspects of Heat Pump Utilization

    Directory of Open Access Journals (Sweden)

    R. Najman

    2010-01-01

    Full Text Available This work attempts to answer the question: How much can we believe that the coefficient of performance provided by the manufacturer is correct, when a heat pump is required to face the real load coming from changes of temperature? The paper summarizes some basics of heat pump theory and describes the results of numerical models.

  14. Standard monitoring system for domestic heat pumps

    NARCIS (Netherlands)

    Geelen, C.P.J.M.; Oostendorp, P.A.

    1999-01-01

    In the years to come many domestic heat pump systems are to be installed in the Netherlands. The Dutch agency for energy and environment, NOVEM, and the association of energy utility companies, EnergieNed, give high priority to the monitoring of heat pump systems. The results of the projects,

  15. ENERGY STAR Certified Geothermal Heat Pumps

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Geothermal Heat Pumps that are effective as of January 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=geo_heat.pr_crit_geo_heat_pumps

  16. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  17. A review of pumped energy storage schemes

    International Nuclear Information System (INIS)

    Unsworth, G.N.

    1975-07-01

    The comparative advantages and costs of pumped water storage, steam accumulators, storage of boiler feedwater , and compressed air storage in caverns are described. Boiler feedwater storage in caverns and pumped water storage are most economical. All systems are costly enough to justify developing reactors with load following capabilities. (E.C.B.)

  18. Piezoelectric pump and pressurised circuit provided therewith

    NARCIS (Netherlands)

    Van Es, Johannes; Wits, Wessel Willems

    2015-01-01

    A piezoelectric pump for use in a pressurised circuit is provided, comprising a pump chamber (5) with an inlet (6) provided with a one way inlet valve (7), for connection to a feeding line (8) of the pressurised circuit and an outlet (9) provided with a one way outlet valve (10), for connection to a

  19. Mathematical model of the reactor coolant pump

    International Nuclear Information System (INIS)

    Kozuh, M.

    1989-01-01

    The mathematical model of reactor coolant pump is described in this paper. It is based on correlations for centrifugal reactor coolant pumps. This code is one of the elements needed for the simulation of the whole NPP primary system. In subroutine developed according to this model we tried in every possible detail to incorporate plant specific data for Krsko NPP. (author)

  20. Minimum maintenance solar pump | Assefa | Zede Journal

    African Journals Online (AJOL)

    A minimum maintenance solar pump (MMSP), Fig 1, has been simulated for Addis Ababa, taking solar meteorological data of global radiation, diffuse radiation and ambient air temperature as input to a computer program that has been developed. To increase the performance of the solar pump, by trapping the long-wave ...

  1. Double-shell tank emergency pumping guide

    International Nuclear Information System (INIS)

    BROWN, M.H.

    1999-01-01

    This Double-Shell Tank Emergency Pumping Guide provides the preplanning necessary to expeditiously remove any waste that may leak from the primary tank to the secondary tank for Hanfords 28 DSTs. The strategy is described, applicable emergency procedures are referenced, and transfer routes and pumping equipment for each tank are identified

  2. A model of annular linear induction pumps

    Energy Technology Data Exchange (ETDEWEB)

    Momozaki, Yoichi [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-10-27

    The present work explains how the magnetic field and the induced current are obtained when the distributed coils are powered by a 3 phase power supply.  From the magnetic field and the induced current, the thrust and the induction losses in the pump can be calculated to estimate the pump performance.

  3. Double-shell tank emergency pumping guide

    International Nuclear Information System (INIS)

    BROWN, M.H.

    1999-01-01

    This Double-Shell Tank Emergency Pumping Guide provides the preplanning necessary to expeditiously remove any waste that may leak from the primary tank to the secondary tank for Hanford's 28 DSTS. The strategy is described, applicable emergency procedures are referenced, and transfer routes and pumping equipment for each tank are identified

  4. Fluid structure interaction in piston diaphragm pumps

    NARCIS (Netherlands)

    Van Rijswick, R.; Van Rhee, C.

    2013-01-01

    Piston diaphragm pumps are used world-wide for the transport of aggressive and/or abrasive fluids in the chemical, mining and mineral processing industries. Figure 1 shows a cross section of a piston diaphragm pump as is used in the mining and mineral processing industries for the transport of

  5. MINIMUM MAINTENANCE SOLAR PUMP Abebayehu Assefa ...

    African Journals Online (AJOL)

    increase the performance of the solar pump, by trapping the long-wave light rays leaving the absorber - the water tank, two glass covers have been employed. .... Absorptivity of panel. 0.95. Transmissivity of glass. 0.90. Volume of tank. 0.202 m 3. (15). (14) mwev -. Vv. The pumping head of water is determined from Eq.

  6. 14 CFR 27.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 27.991 Section 27.991 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.991 Fuel pumps. Compliance with...

  7. 14 CFR 29.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 29.991 Section 29.991 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.991 Fuel pumps. (a...

  8. Numerical routine for magnetic heat pump cascading

    DEFF Research Database (Denmark)

    Filonenko, Konstantin; Lei, Tian; Engelbrecht, Kurt

    Heat pumps use low-temperature heat absorbed from the energy source to create temperature gradient (TG) across the energy sink. Magnetic heat pumps (MHP) can perform this function through operating active magnetic regeneration (AMR) cycle. For building heating, TGs of up to a few K might...

  9. Cladding For Transversely-Pumped Laser Rod

    Science.gov (United States)

    Byer, Robert L.; Fan, Tso Yee

    1989-01-01

    Combination of suitable dimensioning and cladding of neodymium:yttrium aluminum garnet of similar solid-state laser provides for more efficient utilization of transversely-incident pump light from diode lasers. New design overcomes some of limitations of longitudinal- and older transverse-pumping concepts and promotes operation at higher output powers in TEM00 mode.

  10. Spare mitigation/retrieval mixer pumps

    International Nuclear Information System (INIS)

    Taylor, S.

    1995-01-01

    This document presents the functional design criteria for design, analysis, fabrication, testing, and installation of a waste tank mixer pump. The mixer pump will be operated to eliminate the periodic releases of large quantities of flammable gas (e.g., hydrogen) from Hanford Site waste tanks and also to accommodate retrieval of tank waste

  11. Pumps for medium sized solar systems

    DEFF Research Database (Denmark)

    Furbo, Simon

    1996-01-01

    The suitability of the electronically controlled circulation pump type UPE 2000 from Grundfos for large solar heating systems was elucidated.......The suitability of the electronically controlled circulation pump type UPE 2000 from Grundfos for large solar heating systems was elucidated....

  12. Space Station Water Processor Process Pump

    Science.gov (United States)

    Parker, David

    1995-01-01

    This report presents the results of the development program conducted under contract NAS8-38250-12 related to the International Space Station (ISS) Water Processor (WP) Process Pump. The results of the Process Pumps evaluation conducted on this program indicates that further development is required in order to achieve the performance and life requirements for the ISSWP.

  13. Pump Component Model in SPACE Code

    International Nuclear Information System (INIS)

    Kim, Byoung Jae; Kim, Kyoung Doo

    2010-08-01

    This technical report describes the pump component model in SPACE code. A literature survey was made on pump models in existing system codes. The models embedded in SPACE code were examined to check the confliction with intellectual proprietary rights. Design specifications, computer coding implementation, and test results are included in this report

  14. Fabrication of micro metallic valve and pump

    Science.gov (United States)

    Yang, Ming; Kabasawa, Yasunari; Ito, Kuniyoshi

    2010-03-01

    Fabrication of micro devices by using micro metal forming was proposed by the authors. We developed a desktop servo-press machine with precise tooling system. Precise press forming processes including micro forging and micro joining has been carried out in a progressive die. In this study, micro metallic valve and pump were fabricated by using the precise press forming. The components are made of sheet metals, and assembled in to a unit in the progressive die. A micro check-valve with a diameter of 3mm and a length of 3.2mm was fabricated, and the property of flow resistance was evaluated. The results show that the check valve has high property of leakage proof. Since the valve is a unit parts with dimensions of several millimeters, it has advantage to be adapted to various pump design. Here, two kinds of micro pumps with the check-valves were fabricated. One is diaphragm pump actuated by vibration of the diaphragm, and another is tube-shaped pump actuated by resonation. The flow quantities of the pumps were evaluated and the results show that both of the pumps have high pumping performance.

  15. Tokamak advanced pump limiter experiments and analysis

    International Nuclear Information System (INIS)

    Conn, R.W.

    1983-06-01

    Experiments with pump limiter modules on several operating tokamaks establish such limiters as efficient collectors of particles and has demonstrated the importance of ballistic scattering as predicted theoretically. Plasma interaction with recycling neutral gas appears to become important as the plasma density increases and the effective ionization mean free path within the module decreases. In limiters with particle collection but without active internal pumping, the neutral gas pressure is found to vary nonlinearly with the edge plasma density at the highest densities studies. Both experiments and theory indicate that the energy spectrum of gas atoms in the pump ducting is non-thermal, consistent with the results of Monte Carlo neutral atom transport calculations. The distribution of plasma power over the front surface of such modules has been measured and appears to be consistent with the predictions of simple theory. Initial results from the latest experiment on the ISX-B tokamak with an actively pumped limiter module demonstrates that the core plasma density can be controlled with a pump limiter and that the scrape-off layer plasma can partially screen the core plasma from gas injection. The results from module pump limiter experiments and from the theory and design analysis of advanced pump limiters for reactors are used to suggest the major features of a definitive, axisymmetric, toroidal belt pump limiter experiment

  16. A new technique for pumping hydrogen gas

    Science.gov (United States)

    Friedman, I.; Hardcastle, K.

    1970-01-01

    A system for pumping hydrogen gas without isotopic fractionation has been developed. The pump contains uranium metal, which when heated to about 80??C reacts with hydrogen to form UH3. The UH3 is heated to above 500??C to decompose the hydride and regenerate the hydrogen. ?? 1970.

  17. Piezo pump and pressurized circuit provided therewith

    NARCIS (Netherlands)

    Van Es, Johannes; Wits, Wessel Willems

    2015-01-01

    A piezo pump for use in a pressurized circuit includes a pump chamber with an inlet provided with a one way inlet valve, for connection to a feeding line of the pressurized circuit and an outlet provided with a one way outlet valve, for connection to a discharge line of the pressurized circuit and a

  18. Fault Detection and Isolation in Centrifugal Pumps

    DEFF Research Database (Denmark)

    KallesĂže, Carsten

    Centrifugal pumps are used in a variety of different applications, such as water supply, wastewater, and different industrial applications. Some pump installations are crucial for the applications to work. Failures can lead to substantial economic losses and can influence the life of many people...

  19. 46 CFR 132.120 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... deck. (g) No branch line may be directly connected to the fire main except for fighting fires or for... main system, it must lead from a discharge manifold near the fire pump. (i) The total cross-sectional... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 132.120 Section 132.120 Shipping COAST GUARD...

  20. Pump limiter experiment in the TFR tokamak

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Pump limiter experiments are carried out in the TFR Tokamak. The first TFR pump limiter is located in the outer part of the torus, its double-throat head is made of graphite tiles, the neutralizer plates are made of stainless steel, and it is pumped by a 3500 l s -1 titanium sublimation pump. The first attempts showed that the exhaust efficiency Δ of this pump limiter was low (1.5% of the total plasma particle efflux). To improve on these results, a new limiter head with a single longer throat has been built. The particles were better trapped and the pumping achieved an important decrease of the recycling coefficient. Geometric features and also the highly non linear regime of pressure in the pump limiter as a function of the density at the entrance slot could explain the increase by a factor 3.5 of the exhaust efficiency (Δ = 5%). Ion temperatures of the order of a few eV have been deduced from Doppler broadening measurements at the neutralizer plate of the pump limiter. (orig.)

  1. Reactor primary pumps dynamic balancing test

    International Nuclear Information System (INIS)

    Lu Qunxian

    2002-01-01

    Reactor primary Pump is the important equipment in the primary circuit, its working quality would directly influence the safety and operation of nuclear power plant. The author describes that the primary pump vibration status, vibration fault diagnosis and dynamic balancing process on site have been performed since commercial operation of DA YA BAY Nuclear Power plant

  2. Emergency recirculation pump driving mechanism

    International Nuclear Information System (INIS)

    Morooka, Shin-ichi.

    1980-01-01

    Purpose: To sufficiently secure the coolant flow rate in a reactor core and restrict the temperature on the surface of fuel elements to low degree when the coolant is lost in a BWR type reactor. Constitution: In order to secure sufficient coolant flow rate in a reactor core and to sufficiently cool the reactor core when the coolant is lost in a BWR type reactor, it is tripped upon loss of power supply simultaneously when an accident occurs, a recycling pump at the side of normal reactor where its rotating speed is decelerated in accordance with its inertia is restarted by the pressure water stored in a tank out of the reactor to increase the coolant flow rate in the reactor core so as to sufficiently cool the reactor core. (Aizawa, K.)

  3. Replacement Saltwell Pumping System Document Bibliography

    International Nuclear Information System (INIS)

    BELLOMY, J.R.

    2000-01-01

    This document bibliography is prepared to identify engineering documentation developed during the design of the Replacement Saltwell Pumping System. The bibliography includes all engineering supporting documents and correspondence prepared prior to the deployment of the system in the field. All documents referenced are available electronically through the Records Management Information System (RMIS). Major components of the Replacement Saltwell Pumping System include the Sundyne Canned Motor Pump, the Water Filter Skid, the Injection Water Skid and the Backflow Preventer Assembly. Drawing H-14-104498 provides an index of drawings (fabrication details, PandIDs, etc.) prepared to support development of the Replacement Saltwell Pumping System. Specific information pertaining to new equipment can be found in Certified Vendor Information (CVI) File 50124. This CVI file has been established specifically for new equipment associated with the Replacement Saltwell Pumping System

  4. A review of magnetic heat pump technology

    International Nuclear Information System (INIS)

    Barclay, J.A.

    1990-01-01

    The area of technology classified as heat pumps generally refers to refrigerators, heat pumps and heat engines. This review is restricted to the literature on magnetic refrigerators and magnetic heat pumps which are referred to interchangeably. Significant progress has been made on the development of engineering prototypes of cryogenic, nonregenerative magnetic refrigerators utilizing conductive heat transfer in the 0.1 K to 20 K temperature range. Advances have also been made in analysis of regenerative magnetic refrigerators and heat pumps utilizing the active magnetic regeneration (AMR) concept. Units based on AMR are being modeled, designed and/or built to operate in various temperature ranges including 1.8-4.5 K, 4-15 K, 15-85 K, and 270-320 K. The near room temperature units have been scaled to 50 kW as both refrigerators and heat pumps. The progress of magnetic refrigeration over the last three years is summarized and discussed

  5. Jet pumps hydrdynamics for application on BWRS

    International Nuclear Information System (INIS)

    Girardi, G.; Pitimada, D.

    1979-01-01

    An analysis of single-phase jet-pump hydrodynamics is carried out by this paper with special regard to the applications on cooling water recirculation in the boiling water reactors (BWR). Firstly, in order to asses on efficiency of jet pumps, several theories regarding the hydrodynamic of these machines are also investigated. The results of the above theories are critically analysed and compared regarding to water-jet-pump design, to operational performance curves and to section limits. Some general criteria in jet-pump design are introduced and values of geometric and kinematic parameters are suggested together with losses coefficients which are all concerned with the ''high ratio'' type jet pump of this typical application. Finally, the experimental test program following the sim of this research is briefly described

  6. Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

    Science.gov (United States)

    Willis, Peter; White, Victor; Grunthaner, Frank; Ikeda, Mike; Mathies, Richard A.

    2009-01-01

    Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

  7. Structure and operation of bacterial tripartite pumps.

    Science.gov (United States)

    Hinchliffe, Philip; Symmons, Martyn F; Hughes, Colin; Koronakis, Vassilis

    2013-01-01

    In bacteria such as Pseudomonas aeruginosa and Escherichia coli, tripartite membrane machineries, or pumps, determine the efflux of small noxious molecules, such as detergents, heavy metals, and antibiotics, and the export of large proteins including toxins. They are therefore influential in bacterial survival, particularly during infections caused by multidrug-resistant pathogens. In these tripartite pumps an inner membrane transporter, typically an ATPase or proton antiporter, binds and translocates export or efflux substrates. In cooperation with a periplasmic adaptor protein it recruits and opens a TolC family cell exit duct, which is anchored in the outer membrane and projects across the periplasmic space between inner and outer membranes. Assembled tripartite pumps thus span the entire bacterial cell envelope. We review the atomic structures of each of the three pump components and discuss how these have allowed high-resolution views of tripartite pump assembly, operation, and possible inhibition.

  8. Concrete volute pumps: technology review and improvement

    Science.gov (United States)

    PruniĂšres, R.; Longatte, F.; Catelan, F. X.; Philippot, J. M.

    2012-11-01

    When pumps need to deliver large water flow rates (typically more than 5 m3.s-1), concrete volute pumps (CVP) offer an interesting alternative to standard vertical wet-pit pumps. One of the major advantages of CVP is its simplicity in terms of design, manufacturability and maintainability. In addition, CVP geometrical arrangement allows to reach high performances in terms of hydraulic and mechanical behaviour. These advantages can be specifically appreciated when such pumps are used in the energy field for Power Plants which need high flow rate and reliability, and can lead to important financial savings over the Plant lifetime compared to vertical wet-pit pumps. Finally, as CVP was for a long time limited to total head rise lower than 30 mWC, it was established through CFD analysis that the addition of guide vanes between the impeller and the volute allows to achieve higher head rise without risk.

  9. D-Zero HVAC Heat Pump Controls

    International Nuclear Information System (INIS)

    Markley, Dan

    2004-01-01

    This engineering note documents the integration of Dzero Heat Pump 1 through Heat Pump 15 into the cryo/gas process control system commonly referred to as the cryo control system. Heat pumps 1 through 15 control the ambient air temperature on the 3rd, 5th, and 6th floor office areas at Dzero. The entire Johnson HVAC control system was replaced with a Siemens control system in 1999 leaving behind the 15 heat pumps with stand-alone Johnson controllers. Now, these 15 heat pump Johnson controllers are being replaced with small stand alone Beckhoff BC9000 controllers. The Beckhoff BC9000 controllers are network able into the existing Intellution control system. The Beckhoff BC9000 controllers use the cryo private Ethernet network and an OPC driver to get data into the Intellution SCADA node databases. The BC9000 is also programmed over this same Ethernet network.

  10. Alizes: Wind pumping project in Mauritania

    International Nuclear Information System (INIS)

    Monvois, J.; Reboulet, M.

    1991-01-01

    GRET started the title project in May 1990. About 50,000 people live in the area around Rosso, Mauritania, where the project is located. An essential aspect of the project is that villagers themselves need to ask for a wind pump. Moreover, the wind pumps are locally manufactured by a small enterprise. The counterparts are the Mauritanian Ministry of Energy, and the non-gouvernmental Institute Dello and Espace Eolien Regional in France. The Oasis multibladed windmill (2,5 diameter) was chosen, because it is easy to manufacture, it is easy to maintain and quite cheap. To avoid problems it is decided not to pump water from a depth more than 20 meters. The total costs of a wind pump amount to approximately US$ 8,000. for obtaining a wind pump, the villagers need to pay 15% of this total amount. 5 figs., 1 tab

  11. Preventative maintenance plan for emergency pumping trailers

    International Nuclear Information System (INIS)

    Wiggins, D.D.

    1994-09-01

    The purpose/goal of this document is to identify the maintenance requirements and resources available to properly maintain the readiness and condition of the Emergency Pumping Equipment controlled by the Tank Waste Remediation System Tank Farms Plant Engineering and Tank Stabilization Operations. This equipment is intended to pump a single-shell tank (SST) that has been identified as an assumed leaking tank. The goal is to commence pumping (submersible or jet) as soon as safely possible after identifying a SST as an assumed leaking tank. Important information pertaining to the Emergency Pumping Equipment, Over-Ground Piping installation, and procedures is found in WHC-SD-WM-AP-005, ''Single Shell Tank Leak Emergency Pumping Guide.''

  12. Hybrid pump for Pazflor deepwater development

    Energy Technology Data Exchange (ETDEWEB)

    Bibet, Pierre-Jean

    2010-07-01

    Subsea Processing gives engineers permanent technical challenges due to the comprehensive specifications which often stretch the proven limits of technology. It is particularly true for pumps that have to boost a multiphase effluent, because they must, often at the same time, be tolerant to free gas, able to handle very viscous, generate a high ?P, and be efficient. The Pazflor project decided to base the development on full utilization of subsea pumps. This paper presents the state of the art of the pumps that are designed to be installed on the sea floor. It further describes why existing technology could not match the technical requirements for the Pazflor project. It finally presents the pump specifically developed for this world first full field's development application, the so called 'Hybrid Pump', with the description of the associated qualification program and results. (Author)

  13. Improvement of centrifugal pump performance through addition of splitter blades on impeller pump

    Science.gov (United States)

    Kurniawan, Krisna Eka; Santoso, Budi; Tjahjana, Dominicus Danardono Dwi Prija

    2018-02-01

    The workable way to improve pump performance is to redesign or modify the impellers of centrifugal pump. The purpose of impeller pump modification is to improve pump efficiency, reduce cross flow, reduce secondary incidence flows, and decrease backflow areas at impeller outlets. Number blades and splitter blades in the impeller are three. The outlet blade angle is 20°, and the rotating speed of impeller is 2400 rpm. The added splitter blades variations are 0.25, 0.375, and 0.5 of the original blade length. The splitter blade placements are on the outer side of the impeller. The addition of splitter blades on the outer side of the impeller with 0.5L increases the pump head until 22% and the pump has 38.66% hydraulic efficiency. The best efficiency point of water flow rate pump (Qbep) was 3.02 × 10-3 m3/s.

  14. Pumping behavior of ion pump elements at high and misaligned magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Hseuh, H. C.; Jiang, W. S.; Mapes, M.

    1994-11-01

    The pumping speeds of several diode type ion pump elements with cell radii of 5 mm, 5.5 mm, 6 mm, 9 mm and 12 mm were measured while being subjected to a magnetic field B, ranging from 500 Gauss up to 15 KG, and misalignment angles (angles between the direction of B and the anode axis) from 0 to 13 degrees. The pumping speeds of elements with the 9 mm and 12 mm cells peaked around 1--2 KG, then dropped off rapidly with an increasing magnetic field. The pumping speeds of the smaller cell elements remained constant with an increasing magnetic field. The pumping speeds of all the elements decreased with increasing misalignment. The measured pumping speeds from this study are 3--4 times lower than the calculated pumping, speeds using previously reported empirical formulae.

  15. Pumping behavior of ion pump elements at high and misaligned magnetic fields

    International Nuclear Information System (INIS)

    Hseuh, H.C.; Jiang, W.S.; Mapes, M.

    1994-01-01

    The pumping speeds of several diode type ion pump elements with cell radii of 5 mm, 5.5 mm, 6 mm, 9 mm and 12 mm were measured while being subjected to a magnetic field B, ranging from 500 Gauss up to 15 KG, and misalignment angles (angles between the direction of B and the anode axis) from 0 to 13 degrees. The pumping speeds of elements with the 9 mm and 12 mm cells peaked around 1--2 KG, then dropped off rapidly with an increasing magnetic field. The pumping speeds of the smaller cell elements remained constant with an increasing magnetic field. The pumping speeds of all the elements decreased with increasing misalignment. The measured pumping speeds from this study are 3--4 times lower than the calculated pumping, speeds using previously reported empirical formulae

  16. Off-Pump Versus On-Pump Coronary Artery Bypass Grafting

    DEFF Research Database (Denmark)

    MĂžller, Christian H; SteinbrĂŒchel, Daniel A

    2014-01-01

    Coronary artery bypass grafting (CABG) remains the preferred treatment in patients with complex coronary artery disease. However, whether the procedure should be performed with or without the use of cardiopulmonary bypass, referred to as off-pump and on-pump CABG, is still up for debate....... Intuitively, avoidance of cardiopulmonary bypass seems beneficial as the systemic inflammatory response from extracorporeal circulation is omitted, but no single randomized trial has been able to prove off-pump CABG superior to on-pump CABG as regards the hard outcomes death, stroke or myocardial infarction....... In contrast, off-pump CABG is technically more challenging and may be associated with increased risk of incomplete revascularization. The purpose of the review is to summarize the current literature comparing outcomes of off-pump versus on-pump coronary artery bypass surgery....

  17. Preliminary design of RDE feedwater pump impeller

    International Nuclear Information System (INIS)

    Sri Sudadiyo

    2018-01-01

    Nowadays, pumps are being widely used in the thermal power generation including nuclear power plants. Reaktor Daya Experimental (RDE) is a proposed nuclear reactor concept for the type of nuclear power plant in Indonesia. This RDE has thermal power 10 MW th , and uses a feedwater pump within its steam cycle. The performance of feedwater pump depends on size and geometry of impeller model, such as the number of blades and the blade angle. The purpose of this study is to perform a preliminary design on an impeller of feedwater pump for RDE and to simulate its performance characteristics. The Fortran code is used as an aid in data calculation in order to rapidly compute the blade shape of feedwater pump impeller, particularly for a RDE case. The calculations analyses is solved by utilizing empirical correlations, which are related to size and geometry of a pump impeller model, while performance characteristics analysis is done based on velocity triangle diagram. The effect of leakage, pass through the impeller due to the required clearances between the feedwater pump impeller and the volute channel, is also considered. Comparison between the feedwater pump of HTR-10 and of RDE shows similarity in the trend line of curve shape. These characteristics curves will be very useful for the values prediction of performance of a RDE feedwater pump. Preliminary design of feedwater pump provides the size and geometry of impeller blade model with 5-blades, inlet angle 14.5 degrees, exit angle 25 degrees, inside diameter 81.3 mm, exit diameter 275.2 mm, thickness 4.7 mm, and height 14.1 mm. In addition, the optimal values of performance characteristics were obtained when flow capacity was 4.8 kg/s, fluid head was 29.1 m, shaft mechanical power was 2.64 kW, and efficiency was 52 % at rotational speed 1750 rpm. (author)

  18. Optimum pump armament in supply networks; Optimal pumpebestykning i forsynignssystemer

    Energy Technology Data Exchange (ETDEWEB)

    Kristjansson, Halldor

    2005-06-15

    The report presents recommendations as regards pump armament in district heating pump centres and the linked savings. A model has been built which shows variations of efficiency for motor and pump. (BA)

  19. Electron-beam pumping of visible and ultraviolet gas lasers

    International Nuclear Information System (INIS)

    Bradley, L.P.

    1975-01-01

    Several techniques for using direct electron-pumping of gas lasers are reviewed. The primary objective is to categorize pump geometries and to give guidelines for gun selection and pulser design. Examples and application of pump technology are given

  20. Condensate and feedwater systems, pumps, and water chemistry. Volume seven

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Subject matter includes condensate and feedwater systems (general features of condensate and feedwater systems, condenser hotwell level control, condensate flow, feedwater flow), pumps (principles of fluid flow, types of pumps, centrifugal pumps, positive displacement pumps, jet pumps, pump operating characteristics) and water chemistry (water chemistry fundamentals, corrosion, scaling, radiochemistry, water chemistry control processes, water pretreatment, PWR water chemistry, BWR water chemistry, condenser circulating water chemistry