WorldWideScience

Sample records for vainshtein screening mechanism

  1. Cosmic web and environmental dependence of screening: Vainshtein vs. chameleon

    Energy Technology Data Exchange (ETDEWEB)

    Falck, Bridget; Koyama, Kazuya; Zhao, Gong-Bo, E-mail: bridget.falck@port.ac.uk, E-mail: kazuya.koyama@port.ac.uk, E-mail: gong-bo.zhao@port.ac.uk [Institute of Cosmology and Gravitation, University of Portsmouth, Burnaby Road, Portsmouth (United Kingdom)

    2015-07-01

    Theories which modify general relativity to explain the accelerated expansion of the Universe often use screening mechanisms to satisfy constraints on Solar System scales. We investigate the effects of the cosmic web and the local environmental density of dark matter halos on the screening properties of the Vainshtein and chameleon screening mechanisms. We compare the cosmic web morphology of dark matter particles, mass functions of dark matter halos, mass and radial dependence of screening, velocity dispersions and peculiar velocities, and environmental dependence of screening mechanisms in f(R) and nDGP models. Using the ORIGAMI cosmic web identification routine we find that the Vainshtein mechanism depends on the cosmic web morphology of dark matter particles, since these are defined according to the dimensionality of their collapse, while the chameleon mechanism shows no morphology dependence. The chameleon screening of halos and their velocity dispersions depend on halo mass, and small halos and subhalos can be environmentally screened in the chameleon mechanism. On the other hand, the screening of halos in the Vainshtein mechanism does not depend on mass nor environment, and their velocity dispersions are suppressed. The peculiar velocities of halos in the Vainshtein mechanism are enhanced because screened objects can still feel the fifth force generated by external fields, while peculiar velocities of chameleon halos are suppressed when the halo centers are screened.

  2. Cosmic web and environmental dependence of screening: Vainshtein vs. chameleon

    International Nuclear Information System (INIS)

    Falck, Bridget; Koyama, Kazuya; Zhao, Gong-Bo

    2015-01-01

    Theories which modify general relativity to explain the accelerated expansion of the Universe often use screening mechanisms to satisfy constraints on Solar System scales. We investigate the effects of the cosmic web and the local environmental density of dark matter halos on the screening properties of the Vainshtein and chameleon screening mechanisms. We compare the cosmic web morphology of dark matter particles, mass functions of dark matter halos, mass and radial dependence of screening, velocity dispersions and peculiar velocities, and environmental dependence of screening mechanisms in f(R) and nDGP models. Using the ORIGAMI cosmic web identification routine we find that the Vainshtein mechanism depends on the cosmic web morphology of dark matter particles, since these are defined according to the dimensionality of their collapse, while the chameleon mechanism shows no morphology dependence. The chameleon screening of halos and their velocity dispersions depend on halo mass, and small halos and subhalos can be environmentally screened in the chameleon mechanism. On the other hand, the screening of halos in the Vainshtein mechanism does not depend on mass nor environment, and their velocity dispersions are suppressed. The peculiar velocities of halos in the Vainshtein mechanism are enhanced because screened objects can still feel the fifth force generated by external fields, while peculiar velocities of chameleon halos are suppressed when the halo centers are screened

  3. The Vainshtein mechanism in the cosmic web

    Energy Technology Data Exchange (ETDEWEB)

    Falck, Bridget; Koyama, Kazuya [Institute of Cosmology and Gravitation, University of Portsmouth, Dennis Sciama Building, Portsmouth, PO1 3FX (United Kingdom); Zhao, Gong-bo [National Astronomy Observatories, Chinese Academy of Science, Beijing, 100012 (China); Li, Baojiu, E-mail: bridget.falck@port.ac.uk, E-mail: kazuya.koyama@port.ac.uk, E-mail: gong-bo.zhao@port.ac.uk, E-mail: baojiu.li@durham.ac.uk [Institute for Computational Cosmology, Physics Department, University of Durham, South Road, Durham, DH1 3LE (United Kingdom)

    2014-07-01

    We investigate the dependence of the Vainshtein screening mechanism on the cosmic web morphology of both dark matter particles and halos as determined by ORIGAMI. Unlike chameleon and symmetron screening, which come into effect in regions of high density, Vainshtein screening instead depends on the dimensionality of the system, and screened bodies can still feel external fields. ORIGAMI is well-suited to this problem because it defines morphologies according to the dimensionality of the collapsing structure and does not depend on a smoothing scale or density threshold parameter. We find that halo particles are screened while filament, wall, and void particles are unscreened, and this is independent of the particle density. However, after separating halos according to their large scale cosmic web environment, we find no difference in the screening properties of halos in filaments versus halos in clusters. We find that the fifth force enhancement of dark matter particles in halos is greatest well outside the virial radius. We confirm the theoretical expectation that even if the internal field is suppressed by the Vainshtein mechanism, the object still feels the fifth force generated by the external fields, by measuring peculiar velocities and velocity dispersions of halos. Finally, we investigate the morphology and gravity model dependence of halo spins, concentrations, and shapes.

  4. The Vainshtein mechanism in the cosmic web

    International Nuclear Information System (INIS)

    Falck, Bridget; Koyama, Kazuya; Zhao, Gong-bo; Li, Baojiu

    2014-01-01

    We investigate the dependence of the Vainshtein screening mechanism on the cosmic web morphology of both dark matter particles and halos as determined by ORIGAMI. Unlike chameleon and symmetron screening, which come into effect in regions of high density, Vainshtein screening instead depends on the dimensionality of the system, and screened bodies can still feel external fields. ORIGAMI is well-suited to this problem because it defines morphologies according to the dimensionality of the collapsing structure and does not depend on a smoothing scale or density threshold parameter. We find that halo particles are screened while filament, wall, and void particles are unscreened, and this is independent of the particle density. However, after separating halos according to their large scale cosmic web environment, we find no difference in the screening properties of halos in filaments versus halos in clusters. We find that the fifth force enhancement of dark matter particles in halos is greatest well outside the virial radius. We confirm the theoretical expectation that even if the internal field is suppressed by the Vainshtein mechanism, the object still feels the fifth force generated by the external fields, by measuring peculiar velocities and velocity dispersions of halos. Finally, we investigate the morphology and gravity model dependence of halo spins, concentrations, and shapes

  5. Screening fifth forces in k-essence and DBI models

    Energy Technology Data Exchange (ETDEWEB)

    Brax, Philippe [Institut de Physique Théorique, CEA, IPhT, CNRS, URA2306, F-91191 Gif-sur-Yvette cédex (France); Burrage, Clare [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); Davis, Anne-Christine, E-mail: Philippe.Brax@cea.fr, E-mail: Clare.Burrage@nottingham.ac.uk, E-mail: A.C.Davis@damtp.cam.ac.uk [Department of Applied Mathematics and Theoretical Physics, Centre for Mathematical Sciences, Cambridge CB3 0WA (United Kingdom)

    2013-01-01

    New fifth forces have not yet been detected in the laboratory or in the solar system, hence it is typically difficult to introduce new light scalar fields that would mediate such forces. In recent years it has been shown that a number of non-linear scalar field theories allow for a dynamical mechanism, such as the Vainshtein and chameleon ones, that suppresses the strength of the scalar fifth force in experimental environments. This is known as screening, however it is unclear how common screening is within non-linear scalar field theories. k-essence models are commonly studied examples of non-linear models, with DBI as the best motivated example, and so we ask whether these non-linearities are able to screen a scalar fifth force. We find that a Vainshtein-like screening mechanism exists for such models although with limited applicability. For instance, we cannot find a screening mechanism for DBI models. On the other hand, we construct a large class of k-essence models which lead to the acceleration of the Universe in the recent past for which the fifth force mediated by the scalar can be screened.

  6. Using voids to unscreen modified gravity

    Science.gov (United States)

    Falck, Bridget; Koyama, Kazuya; Zhao, Gong-Bo; Cautun, Marius

    2018-04-01

    The Vainshtein mechanism, present in many models of gravity, is very effective at screening dark matter haloes such that the fifth force is negligible and general relativity is recovered within their Vainshtein radii. Vainshtein screening is independent of halo mass and environment, in contrast to e.g. chameleon screening, making it difficult to test. However, our previous studies have found that the dark matter particles in filaments, walls, and voids are not screened by the Vainshtein mechanism. We therefore investigate whether cosmic voids, identified as local density minima using a watershed technique, can be used to test models of gravity that exhibit Vainshtein screening. We measure density, velocity, and screening profiles of stacked voids in cosmological N-body simulations using both dark matter particles and dark matter haloes as tracers of the density field. We find that the voids are completely unscreened, and the tangential velocity and velocity dispersion profiles of stacked voids show a clear deviation from Λ cold dark matter at all radii. Voids have the potential to provide a powerful test of gravity on cosmological scales.

  7. Distinguishing modified gravity models

    International Nuclear Information System (INIS)

    Brax, Philippe; Davis, Anne-Christine

    2015-01-01

    Modified gravity models with screening in local environments appear in three different guises: chameleon, K-mouflage and Vainshtein mechanisms. We propose to look for differences between these classes of models by considering cosmological observations at low redshift. In particular, we analyse the redshift dependence of the fine structure constant and the proton to electron mass ratio in each of these scenarios. When the absorption lines belong to unscreened regions of space such as dwarf galaxies, a time variation would be present for chameleons. For both K-mouflage and Vainshtein mechanisms, the cosmological time variation of the scalar field is not suppressed in both unscreened and screened environments, therefore enhancing the variation of constants and their detection prospect. We also consider the time variation of the redshift of distant objects using their spectrocopic velocities. We find that models of the K-mouflage and Vainshtein types have very different spectroscopic velocities as a function of redshift and that their differences with the Λ-CDM template should be within reach of the future ELT-HIRES observations

  8. Distinguishing modified gravity models

    Energy Technology Data Exchange (ETDEWEB)

    Brax, Philippe [Institut de Physique Théorique, Université Paris-Saclay, CEA, CNRS, F-91191 Gif/Yvette Cedex (France); Davis, Anne-Christine, E-mail: philippe.brax@cea.fr, E-mail: A.C.Davis@damtp.cam.ac.uk [DAMTP, Centre for Mathematical Sciences, University of Cambridge, Cambridge, CB3 0WA (United Kingdom)

    2015-10-01

    Modified gravity models with screening in local environments appear in three different guises: chameleon, K-mouflage and Vainshtein mechanisms. We propose to look for differences between these classes of models by considering cosmological observations at low redshift. In particular, we analyse the redshift dependence of the fine structure constant and the proton to electron mass ratio in each of these scenarios. When the absorption lines belong to unscreened regions of space such as dwarf galaxies, a time variation would be present for chameleons. For both K-mouflage and Vainshtein mechanisms, the cosmological time variation of the scalar field is not suppressed in both unscreened and screened environments, therefore enhancing the variation of constants and their detection prospect. We also consider the time variation of the redshift of distant objects using their spectrocopic velocities. We find that models of the K-mouflage and Vainshtein types have very different spectroscopic velocities as a function of redshift and that their differences with the Λ-CDM template should be within reach of the future ELT-HIRES observations.

  9. Astrophysical axion bounds diminished by screening effects

    International Nuclear Information System (INIS)

    Raffelt, G.G.

    1986-01-01

    ''Invisible axions'' could be produced in stellar interiors through Compton- and Primakoff-type photoproduction and through bremsstrahlung processes. We point out that in a plasma screening effects lead to important reductions of these emission rates. Limits on the axion mass and interaction strength are thereby relaxed to values less restrictive than limits previously thought to be firm. For the case of the Sun the Primakoff rate is reduced by two orders of magnitude. This process is the dominant emission mechanism for Kim-Shifman-Vainshtein-Zakharov- (KSVZ) type axions which do not couple directly to electrons. The mass limit is then relaxed by an order of magnitude to m/sub a/ 2 β of the model equals unity. Our results can be easily translated to other hypothetical pseudoscalar particles if they are light compared with typical stellar temperatures

  10. Extrasolar planets as a probe of modified gravity

    Directory of Open Access Journals (Sweden)

    Marcelo Vargas dos Santos

    2017-06-01

    Full Text Available We propose a new method to test modified gravity theories, taking advantage of the available data on extrasolar planets. We computed the deviations from the Kepler third law and use that to constrain gravity theories beyond General Relativity. We investigate gravity models which incorporate three screening mechanisms: the Chameleon, the Symmetron and the Vainshtein. We find that data from exoplanets orbits are very sensitive to the screening mechanisms putting strong constraints in the parameter space for the Chameleon models and the Symmetron, complementary and competitive to other methods, like interferometers and solar system. With the constraints on Vainshtein we are able to work beyond the hypothesis that the crossover scale is of the same order of magnitude than the Hubble radius rc∼H0−1, which makes the screening work automatically, testing how strong this hypothesis is and the viability of other scales.

  11. Extrasolar planets as a probe of modified gravity

    Science.gov (United States)

    Vargas dos Santos, Marcelo; Mota, David F.

    2017-06-01

    We propose a new method to test modified gravity theories, taking advantage of the available data on extrasolar planets. We computed the deviations from the Kepler third law and use that to constrain gravity theories beyond General Relativity. We investigate gravity models which incorporate three screening mechanisms: the Chameleon, the Symmetron and the Vainshtein. We find that data from exoplanets orbits are very sensitive to the screening mechanisms putting strong constraints in the parameter space for the Chameleon models and the Symmetron, complementary and competitive to other methods, like interferometers and solar system. With the constraints on Vainshtein we are able to work beyond the hypothesis that the crossover scale is of the same order of magnitude than the Hubble radius rc ∼ H0-1, which makes the screening work automatically, testing how strong this hypothesis is and the viability of other scales.

  12. Extrasolar planets as a probe of modified gravity

    OpenAIRE

    Vargas dos Santos, Marcelo; Mota, David F.

    2017-01-01

    We propose a new method to test modified gravity theories, taking advantage of the available data on extrasolar planets. We computed the deviations from the Kepler third law and use that to constrain gravity theories beyond General Relativity. We investigate gravity models which incorporate three screening mechanisms: the Chameleon, the Symmetron and the Vainshtein. We find that data from exoplanets orbits are very sensitive to the screening mechanisms putting strong constraints in the parame...

  13. Disformal theories of gravity: from the solar system to cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Sakstein, Jeremy, E-mail: j.a.sakstein@damtp.cam.ac.uk [DAMTP, Centre for Mathematical Sciences, University of Cambridge, Wilberforce Road, Cambridge CB3 0WA (United Kingdom)

    2014-12-01

    This paper is concerned with theories of gravity that contain a scalar coupled both conformally and disformally to matter through the metric. By systematically deriving the non-relativistic limit, it is shown that no new non-linear screening mechanisms are present beyond the Vainshtein mechanism and chameleon-like screening. If one includes the cosmological expansion of the universe, disformal effects that are usually taken to be absent can be present in the solar system. When the conformal factor is absent, fifth-forces can be screened on all scales when the cosmological field is slowly-rolling. We investigate the cosmology of these models and use local tests of gravity to place new constraints on the disformal coupling and find M ∼> O(eV), which is not competitive with laboratory tests. Finally, we discuss the future prospects for testing these theories and the implications for other theories of modified gravity. In particular, the Vainshtein radius of solar system objects can be altered from the static prediction when cosmological time-derivatives are non-negligible.

  14. Disformal theories of gravity: from the solar system to cosmology

    International Nuclear Information System (INIS)

    Sakstein, Jeremy

    2014-01-01

    This paper is concerned with theories of gravity that contain a scalar coupled both conformally and disformally to matter through the metric. By systematically deriving the non-relativistic limit, it is shown that no new non-linear screening mechanisms are present beyond the Vainshtein mechanism and chameleon-like screening. If one includes the cosmological expansion of the universe, disformal effects that are usually taken to be absent can be present in the solar system. When the conformal factor is absent, fifth-forces can be screened on all scales when the cosmological field is slowly-rolling. We investigate the cosmology of these models and use local tests of gravity to place new constraints on the disformal coupling and find M ∼> O(eV), which is not competitive with laboratory tests. Finally, we discuss the future prospects for testing these theories and the implications for other theories of modified gravity. In particular, the Vainshtein radius of solar system objects can be altered from the static prediction when cosmological time-derivatives are non-negligible

  15. Shifman-Vainshtein-Zakharov method: why it works, why it fails, and ways to improve it

    International Nuclear Information System (INIS)

    Durand, L.; Durand, B.; Whitenton, J.B.

    1983-01-01

    Shifman, Vainshtein, and Zakharov (SVZ) have proposed a procedure for calculating hadronic masses and determining nonperturbative parameters in QCD using the operator-product expansion for two-point functions and (exponential) moments of the corresponding spectral functions. In this paper we present a detailed theoretical analysis of the SVZ procedure in the context of nonrelativistic potential theory. We find that the phenomenological success of the usual first-order SVZ method in relating hadronic energies (masses) is due to a hidden variational principle and a semiclassical structure which gives correct JWKB-type relations between energies. The first-order method fails theoretically: it does not reproduce the correct potential-model or field-theoretic parameters, e.g., the gluon-condensate parameter of QCD. We show why it breaks down in this application, and that its reliability can be greatly improved in all applications by using higher-order approximations for the moment function. Our results are directly relevant for the SVZ analysis of charmonium and b-quarkonium. The general conclusions should also hold for light-quark systems

  16. Testing a generalized cubic Galileon gravity model with the Coma Cluster

    Energy Technology Data Exchange (ETDEWEB)

    Terukina, Ayumu; Yamamoto, Kazuhiro; Okabe, Nobuhiro [Department of Physical Sciences, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Matsushita, Kyoko; Sasaki, Toru, E-mail: telkina@theo.phys.sci.hiroshima-u.ac.jp, E-mail: kazuhiro@hiroshima-u.ac.jp, E-mail: okabe@hiroshima-u.ac.jp, E-mail: matusita@rs.kagu.tus.ac.jp, E-mail: j1213703@ed.tus.ac.jp [Department of Physics, Tokyo University of Science, 1-3 Kagurazaka, Shinjuku-ku, Tokyo 162-8601 (Japan)

    2015-10-01

    We obtain a constraint on the parameters of a generalized cubic Galileon gravity model exhibiting the Vainshtein mechanism by using multi-wavelength observations of the Coma Cluster. The generalized cubic Galileon model is characterized by three parameters of the turning scale associated with the Vainshtein mechanism, and the amplitude of modifying a gravitational potential and a lensing potential. X-ray and Sunyaev-Zel'dovich (SZ) observations of the intra-cluster medium are sensitive to the gravitational potential, while the weak-lensing (WL) measurement is specified by the lensing potential. A joint fit of a complementary multi-wavelength dataset of X-ray, SZ and WL measurements enables us to simultaneously constrain these three parameters of the generalized cubic Galileon model for the first time. We also find a degeneracy between the cluster mass parameters and the gravitational modification parameters, which is influential in the limit of the weak screening of the fifth force.

  17. Halo scale predictions of symmetron modified gravity

    Energy Technology Data Exchange (ETDEWEB)

    Clampitt, Joseph; Jain, Bhuvnesh; Khoury, Justin, E-mail: clampitt@sas.upenn.edu, E-mail: bjain@physics.upenn.edu, E-mail: jkhoury@sas.upenn.edu [Center for Particle Cosmology and Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd St., Philadelphia, PA 19104 (United States)

    2012-01-01

    We offer predictions of symmetron modified gravity in the neighborhood of realistic dark matter halos. The predictions for the fifth force are obtained by solving the nonlinear symmetron equation of motion in the spherical NFW approximation. In addition, we compare the three major known screening mechanisms: Vainshtein, Chameleon, and Symmetron around such dark matter halos, emphasizing the significant differences between them and highlighting observational tests which exploit these differences. Finally, we demonstrate the host halo environmental screening effect (''blanket screening'') on smaller satellite halos by solving for the modified forces around a density profile which is the sum of satellite and approximate host components.

  18. Chameleon foreCAST

    OpenAIRE

    Brax, Philippe; Lindner, Axel; Zioutas, Konstantin

    2011-01-01

    Dark energy models, such as the chameleon, where the acceleration of the expansion of the universe results from the dynamics of a scalar field coupled to matter, suffer from the potential existence of a fifth force. Three known mechanisms have been proposed to restore General Relativity in the solar system and the laboratory, which are the symmetron/Damour-Polyakov effect, the Vainshtein property and the chameleon screening. Here, we propose to probe the existence of chameleons in the laborat...

  19. Photoprotection in Plants Optical Screening-based Mechanisms

    CERN Document Server

    Solovchenko, Alexei

    2010-01-01

    Optical screening of excessive and potentially harmful solar radiation is an important photoprotective mechanism, though it has received much less attention in comparison with other systems preventing photooxidative damage to photoautotrophic organisms. This photoprotection in the form of screening appears to be especially important for juvenile and senescing plants as well as under environmental stresses—i.e. in situations where the efficiency of enzymatic ROS elimination, DNA repair and other ‘classical’ photoprotective systems could be impaired. This book represents an attempt to develop an integral view of optical screening-based photoprotection in microalgae and higher plants. Towards this end, the key groups of pigments involved in the screening of ultraviolet and visible components of solar radiation in microalgae and higher plants, and the patterns of their accumulation and distribution within plant cells and tissues, are described. Special attention is paid to the manifestations of screening pi...

  20. A Screening Mechanism Differentiating True from False Pain during Empathy.

    Science.gov (United States)

    Sun, Ya-Bin; Lin, Xiao-Xiao; Ye, Wen; Wang, Ning; Wang, Jin-Yan; Luo, Fei

    2017-09-13

    Empathizing with another's suffering is important in social interactions. Empathic behavior is selectively elicited from genuine, meaningful pain but not from fake, meaningless scenarios. However, the brain's screening mechanism of false information from meaningful events and the time course for the screening process remains unclear. Using EEG combined with principle components analysis (PCA) techniques, here we compared temporal neurodynamics between the observation of pain and no-pain pictures as well as between true (painful expressions and needle-penetrated arms) and false (needle-penetrated faces with neutral expressions) pain pictures. The results revealed that pain vs. no-pain information is differentiated in the very early ERP components, i.e., the N1/P1 for the face and arm pictures categories and the VPP/N170 for the facial expression category while the mid-latency ERP components, N2 and P3, played key roles in differentiating true from false situations. The complex of N2 and P3 components may serve as a screening mechanism through which observers allocate their attentions to more important or relevant events and screen out false environmental information. This is the first study to describe and provide a time course of the screening process during pain empathy. These findings shed new light on the understanding of empathic processing.

  1. Mechanical evaluation of a new sand control screen for SAGD applications

    Energy Technology Data Exchange (ETDEWEB)

    Woiceshyn, G. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Absolute Completion Technologies, Calgary, AB (Canada); Toffanin, E. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Schlumberger Canada Ltd., Calgary, AB (Canada); Xie, J.; Wagg, B. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[C-FER Technologies, Edmonton, AB (Canada); Fan, C. [C-FER Technologies, Edmonton, AB (Canada)

    2008-10-15

    Steam assisted gravity drainage (SAGD) wells normally require the deployment of an open hole completion combining sand control with adequate mechanical strength to withstand aggressive installation loads and serve operational loads. Slotted liners have traditionally been used in western Canada, mainly because of low cost relative to wire-wrapped screen or premium mesh screens. However, slotting base pipe can weaken the mechanical strength. The slot width can also change as the liner deforms under certain load conditions. Operators are therefore interested in alternative technologies to reduce incidents of mechanical failure and loss of sand control of slotted liners in SAGD wells. This paper presented the flush absolute cartridge system (FACS), a newly developed sand screen onto which a 25.4 diameter fusion bonded metal laminate cartridge is directly mounted and secured directly into the base pipe wall. The paper discussed a finite element analysis study that was conducted in order to independently quantify its mechanical strength and integrity for use in SAGD operations. The paper described the liner, as well as the disc geometry, construction and properties. The paper also listed the potential applications for FACS screens and provided a description of the finite element analysis. It was concluded that although FACS satisfies the basic operational criteria, it has very limited ability to absorb additional strain at the end of the thermal cycle. 10 refs., 4 tabs., 22 figs.

  2. Cosmology and modifications of gravity at large distances

    International Nuclear Information System (INIS)

    Ziour, R.

    2010-01-01

    In the framework of General Relativity, the observed current acceleration of the expansion of the Universe requires the presence of a Dark Energy component, whose nature is not well understood. In order to explain the acceleration of the Universe without introducing such a tantalizing source of energy, other gravitation theories have been designed. This thesis is devoted to the study of some of these modified gravity theories, as well as to the observation methods that could constrain them. The first part of this thesis presents a review of modified gravity theories and their motivations. The second part is devoted to the study of the massive gravity theories and of the so-called Vainshtein's mechanism, which allows some of the solutions of Massive Gravity to strongly differ from General Relativity at cosmological scales while satisfying the experimental constraints inside the solar system. For the first time, the validity of the Vainshtein's mechanism is demonstrated, through the study of specific spherically symmetric solutions. The third part deals with scalar modification of gravity; a new model of this sort is presented, inspired by the Vainshtein's mechanism in Massive Gravity. Finally, the fourth part discusses local, astrophysical and cosmological observations that might constrain modified gravity theories. (author)

  3. Performances of screen-printing silver thick films: Rheology, morphology, mechanical and electronic properties

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Jung-Shiun; Liang, Jau-En; Yi, Han-Liou [Department of Chemical Engineering, National Chung Cheng University, Chia Yi 621, Taiwan, ROC (China); Chen, Shu-Hua [China Steel Corporation, Kaohsiung City 806, Taiwan, ROC (China); Hua, Chi-Chung, E-mail: chmcch@ccu.edu.tw [Department of Chemical Engineering, National Chung Cheng University, Chia Yi 621, Taiwan, ROC (China)

    2016-06-15

    Numerous recent applications with inorganic solar cells and energy storage electrodes make use of silver pastes through processes like screen-printing to fabricate fine conductive lines for electron conducting purpose. To date, however, there have been few studies that systematically revealed the properties of the silver paste in relation to the mechanical and electronic performances of screen-printing thick films. In this work, the rheological properties of a series of model silver pastes made of silver powders of varying size (0.9, 1.3, and 1.5 μm) and shape (irregular and spherical) were explored, and the results were systematically correlated with the morphological feature (scanning electron microscopy, SEM) and mechanical (peeling test) and electronic (transmission line method, TLM) performances of screen-printing dried or sintered thick films. We provided evidence of generally intimate correlations between the powder dispersion state in silver pastes—which is shown to be well captured by the rheological protocols employed herein—and the performances of screen-printing thick films. Overall, this study suggests the powder dispersion state and the associated phase behavior of a paste sample can significantly impact not only the morphological and electronic but also mechanical performances of screen-printing thick films, and, in future perspectives, a proper combination of silver powders of different sizes and even shapes could help reconcile quality and stability of an optimum silver paste. - Highlights: • Powder dispersion correlates well with screen-printing thick film performances. • Rheological fingerprints can be utilized to fathom the powder dispersion state. • Good polymer-powder interactions in the paste ensure good powder dispersion. • Time-dependent gel-like viscoelastic features are found with optimum silver pastes. • The size and shape of functional powder affect the dispersion and film performances.

  4. A high throughput mechanical screening device for cartilage tissue engineering.

    Science.gov (United States)

    Mohanraj, Bhavana; Hou, Chieh; Meloni, Gregory R; Cosgrove, Brian D; Dodge, George R; Mauck, Robert L

    2014-06-27

    Articular cartilage enables efficient and near-frictionless load transmission, but suffers from poor inherent healing capacity. As such, cartilage tissue engineering strategies have focused on mimicking both compositional and mechanical properties of native tissue in order to provide effective repair materials for the treatment of damaged or degenerated joint surfaces. However, given the large number design parameters available (e.g. cell sources, scaffold designs, and growth factors), it is difficult to conduct combinatorial experiments of engineered cartilage. This is particularly exacerbated when mechanical properties are a primary outcome, given the long time required for testing of individual samples. High throughput screening is utilized widely in the pharmaceutical industry to rapidly and cost-effectively assess the effects of thousands of compounds for therapeutic discovery. Here we adapted this approach to develop a high throughput mechanical screening (HTMS) system capable of measuring the mechanical properties of up to 48 materials simultaneously. The HTMS device was validated by testing various biomaterials and engineered cartilage constructs and by comparing the HTMS results to those derived from conventional single sample compression tests. Further evaluation showed that the HTMS system was capable of distinguishing and identifying 'hits', or factors that influence the degree of tissue maturation. Future iterations of this device will focus on reducing data variability, increasing force sensitivity and range, as well as scaling-up to even larger (96-well) formats. This HTMS device provides a novel tool for cartilage tissue engineering, freeing experimental design from the limitations of mechanical testing throughput. © 2013 Published by Elsevier Ltd.

  5. Mechanical polishing as an improved surface treatment for platinum screen-printed electrodes

    Directory of Open Access Journals (Sweden)

    Junqiao Lee

    2016-07-01

    Full Text Available The viability of mechanical polishing as a surface pre-treatment method for commercially available platinum screen-printed electrodes (SPEs was investigated and compared to a range of other pre-treatment methods (UV-Ozone treatment, soaking in N,N-dimethylformamide, soaking and anodizing in aqueous NaOH solution, and ultrasonication in tetrahydrofuran. Conventional electrochemical activation of platinum SPEs in 0.5 M H2SO4 solution was ineffective for the removal of contaminants found to be passivating the screen-printed surfaces. However, mechanical polishing showed a significant improvement in hydrogen adsorption and in electrochemically active surface areas (probed by two different redox couples due to the effective removal of surface contaminants. Results are also presented that suggest that SPEs are highly susceptible to degradation by strong acidic or caustic solutions, and could potentially lead to instability in long-term applications due to continual etching of the binding materials. The ability of SPEs to be polished effectively extends the reusability of these traditionally “single-use” devices. Keywords: Screen-printed electrodes, Polishing, Platinum, Activation, Pre-treatment, Cyclic voltammetry

  6. Risk and Interaction Aversion: Screening Mechanisms in the Prisoner's Dilemma Game

    Science.gov (United States)

    Canova, Gabriel A.; Arenzon, Jeferson J.

    2017-09-01

    When the interactions between cooperators (C) and defectors (D) can be partially avoided within a population, there may be an overall enhancement of cooperation. One example of such screening mechanism occurs in the presence of risk-averse agents (loners, L) that are neutral towards others, i.e., both L and its opponent, whatever its strategy, receive the same payoff. Their presence in the Prisoner's Dilemma (PD) game sustains the coexistence of cooperators and defectors far beyond the level attained in their absence. Another screening mechanism is a heterogeneous landscape obtained, for example, by site diluting the lattice. In this case, cooperation is enhanced with some fraction of such inactive, interaction-averse sites. By considering the interplay of both mechanisms, we show that there is an explosive increase in the range of densities, just above the percolation threshold, where neutrality is prevented and loners become extinct, the behavior reverting to the pure PD game. Interestingly, this occurs despite defectors being usually abundant in that region. This has to be compared with the corresponding loner-free region in the undiluted case that, besides being very small, is dominated by cooperators.

  7. Cosmic Tsunamis in Modified Gravity: Disruption of Screening Mechanisms from Scalar Waves.

    Science.gov (United States)

    Hagala, R; Llinares, C; Mota, D F

    2017-03-10

    Extending general relativity by adding extra degrees of freedom is a popular approach for explaining the accelerated expansion of the Universe and to build high energy completions of the theory of gravity. The presence of such new degrees of freedom is, however, tightly constrained from several observations and experiments that aim to test general relativity in a wide range of scales. The viability of a given modified theory of gravity, therefore, strongly depends on the existence of a screening mechanism that suppresses the extra degrees of freedom. We perform simulations, and find that waves propagating in the new degrees of freedom can significantly impact the efficiency of some screening mechanisms, thereby threatening the viability of these modified gravity theories. Specifically, we show that the waves produced in the symmetron model can increase the amplitude of the fifth force and the parametrized post Newtonian parameters by several orders of magnitude.

  8. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures

    CERN Document Server

    Garion, C; Koettig, T; Machiocha, W; Morrone, M

    2015-01-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb-1). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the sup...

  9. AMMOS: Automated Molecular Mechanics Optimization tool for in silico Screening

    Directory of Open Access Journals (Sweden)

    Pajeva Ilza

    2008-10-01

    Full Text Available Abstract Background Virtual or in silico ligand screening combined with other computational methods is one of the most promising methods to search for new lead compounds, thereby greatly assisting the drug discovery process. Despite considerable progresses made in virtual screening methodologies, available computer programs do not easily address problems such as: structural optimization of compounds in a screening library, receptor flexibility/induced-fit, and accurate prediction of protein-ligand interactions. It has been shown that structural optimization of chemical compounds and that post-docking optimization in multi-step structure-based virtual screening approaches help to further improve the overall efficiency of the methods. To address some of these points, we developed the program AMMOS for refining both, the 3D structures of the small molecules present in chemical libraries and the predicted receptor-ligand complexes through allowing partial to full atom flexibility through molecular mechanics optimization. Results The program AMMOS carries out an automatic procedure that allows for the structural refinement of compound collections and energy minimization of protein-ligand complexes using the open source program AMMP. The performance of our package was evaluated by comparing the structures of small chemical entities minimized by AMMOS with those minimized with the Tripos and MMFF94s force fields. Next, AMMOS was used for full flexible minimization of protein-ligands complexes obtained from a mutli-step virtual screening. Enrichment studies of the selected pre-docked complexes containing 60% of the initially added inhibitors were carried out with or without final AMMOS minimization on two protein targets having different binding pocket properties. AMMOS was able to improve the enrichment after the pre-docking stage with 40 to 60% of the initially added active compounds found in the top 3% to 5% of the entire compound collection

  10. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures.

    Science.gov (United States)

    Garion, C.; Dufay-Chanat, L.; Koettig, T.; Machiocha, W.; Morrone, M.

    2015-12-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb-1). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the supporting system that has to minimise the heat inleak into the cold mass. The behaviour during a magnet quench is also presented.

  11. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures

    International Nuclear Information System (INIS)

    Garion, C; Dufay-Chanat, L; Koettig, T; Machiocha, W; Morrone, M

    2015-01-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb -1 ). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the supporting system that has to minimise the heat inleak into the cold mass. The behaviour during a magnet quench is also presented. (paper)

  12. Mechanical and thermal measurements on a 11 m long beam screen in the LHC Magnet Test String during RUN 3A

    CERN Document Server

    Artoos, K; Kos, N

    1999-01-01

    Two eleven meter long beam screens were installed in the third dipole of the LHC Magnet Test String. Instrumentation was used to measure the mechanical and thermal behaviour of the screens during thermal transients and quenches. The horizontal deformation, angular displacement, heating of the screen as a result of the quench induced eddy currents and relative longitudinal displacement between beam screen and magnet end were measured.

  13. Comparative genetic screens in human cells reveal new regulatory mechanisms in WNT signaling

    Science.gov (United States)

    Lebensohn, Andres M; Dubey, Ramin; Neitzel, Leif R; Tacchelly-Benites, Ofelia; Yang, Eungi; Marceau, Caleb D; Davis, Eric M; Patel, Bhaven B; Bahrami-Nejad, Zahra; Travaglini, Kyle J; Ahmed, Yashi; Lee, Ethan; Carette, Jan E; Rohatgi, Rajat

    2016-01-01

    The comprehensive understanding of cellular signaling pathways remains a challenge due to multiple layers of regulation that may become evident only when the pathway is probed at different levels or critical nodes are eliminated. To discover regulatory mechanisms in canonical WNT signaling, we conducted a systematic forward genetic analysis through reporter-based screens in haploid human cells. Comparison of screens for negative, attenuating and positive regulators of WNT signaling, mediators of R-spondin-dependent signaling and suppressors of constitutive signaling induced by loss of the tumor suppressor adenomatous polyposis coli or casein kinase 1α uncovered new regulatory features at most levels of the pathway. These include a requirement for the transcription factor AP-4, a role for the DAX domain of AXIN2 in controlling β-catenin transcriptional activity, a contribution of glycophosphatidylinositol anchor biosynthesis and glypicans to R-spondin-potentiated WNT signaling, and two different mechanisms that regulate signaling when distinct components of the β-catenin destruction complex are lost. The conceptual and methodological framework we describe should enable the comprehensive understanding of other signaling systems. DOI: http://dx.doi.org/10.7554/eLife.21459.001 PMID:27996937

  14. A perturbative approach to the redshift space power spectrum: beyond the Standard Model

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Benjamin; Koyama, Kazuya, E-mail: benjamin.bose@port.ac.uk, E-mail: kazuya.koyama@port.ac.uk [Institute of Cosmology and Gravitation, University of Portsmouth, Burnaby Road, Portsmouth, Hampshire, PO1 3FX (United Kingdom)

    2016-08-01

    We develop a code to produce the power spectrum in redshift space based on standard perturbation theory (SPT) at 1-loop order. The code can be applied to a wide range of modified gravity and dark energy models using a recently proposed numerical method by A.Taruya to find the SPT kernels. This includes Horndeski's theory with a general potential, which accommodates both chameleon and Vainshtein screening mechanisms and provides a non-linear extension of the effective theory of dark energy up to the third order. Focus is on a recent non-linear model of the redshift space power spectrum which has been shown to model the anisotropy very well at relevant scales for the SPT framework, as well as capturing relevant non-linear effects typical of modified gravity theories. We provide consistency checks of the code against established results and elucidate its application within the light of upcoming high precision RSD data.

  15. Surface-screening mechanisms in ferroelectric thin films and their effect on polarization dynamics and domain structures

    Energy Technology Data Exchange (ETDEWEB)

    Kalinin, Sergei V.; Kim, Yunseok; Fong, Dillon D.; Morozovska, Anna N.

    2018-01-25

    For over 70 years, ferroelectric materials have been one of the central research topics for condensed matter physics and material science, an interest driven both by fundamental science and applications. However, ferroelectric surfaces, the key component of ferroelectric films and nanostructures, still present a significant theoretical and even conceptual challenge. Indeed, stability of ferroelectric phase per se necessitates screening of polarization charge. At surfaces, this can lead to coupling between ferroelectric and semiconducting properties of material, or with surface (electro) chemistry, going well beyond classical models applicable for ferroelectric interfaces. In this review, we summarize recent studies of surface-screening phenomena in ferroelectrics. We provide a brief overview of the historical understanding of the physics of ferroelectric surfaces, and existing theoretical models that both introduce screening mechanisms and explore the relationship between screening and relevant aspects of ferroelectric functionalities starting from phase stability itself. Given that the majority of ferroelectrics exist in multiple-domain states, we focus on local studies of screening phenomena using scanning probe microscopy techniques. We discuss recent studies of static and dynamic phenomena on ferroelectric surfaces, as well as phenomena observed under lateral transport, light, chemical, and pressure stimuli. We also note that the need for ionic screening renders polarization switching a coupled physical-electrochemical process and discuss the non-trivial phenomena such as chaotic behavior during domain switching that stem from this.

  16. Surface-screening mechanisms in ferroelectric thin films and their effect on polarization dynamics and domain structures

    Science.gov (United States)

    Kalinin, Sergei V.; Kim, Yunseok; Fong, Dillon D.; Morozovska, Anna N.

    2018-03-01

    For over 70 years, ferroelectric materials have been one of the central research topics for condensed matter physics and material science, an interest driven both by fundamental science and applications. However, ferroelectric surfaces, the key component of ferroelectric films and nanostructures, still present a significant theoretical and even conceptual challenge. Indeed, stability of ferroelectric phase per se necessitates screening of polarization charge. At surfaces, this can lead to coupling between ferroelectric and semiconducting properties of material, or with surface (electro) chemistry, going well beyond classical models applicable for ferroelectric interfaces. In this review, we summarize recent studies of surface-screening phenomena in ferroelectrics. We provide a brief overview of the historical understanding of the physics of ferroelectric surfaces, and existing theoretical models that both introduce screening mechanisms and explore the relationship between screening and relevant aspects of ferroelectric functionalities starting from phase stability itself. Given that the majority of ferroelectrics exist in multiple-domain states, we focus on local studies of screening phenomena using scanning probe microscopy techniques. We discuss recent studies of static and dynamic phenomena on ferroelectric surfaces, as well as phenomena observed under lateral transport, light, chemical, and pressure stimuli. We also note that the need for ionic screening renders polarization switching a coupled physical–electrochemical process and discuss the non-trivial phenomena such as chaotic behavior during domain switching that stem from this. ).

  17. Transport cross sections based on a screened interaction potential: Comparison of classical and quantum-mechanical results

    International Nuclear Information System (INIS)

    Vincent, R.; Juaristi, J.I.; Nagy, I.

    2005-01-01

    Standard classical and quantum-mechanical methods are used to characterize the momentum-transfer cross section needed in energy-loss calculations and simulations for heavy, swift charges moving in an electron gas. By applying a well-known, finite-range screened Coulombic potential energy to model the two-body collision, the quantitative applicability range of the classical cross section is investigated as a function of charge (Z), screening length (R), and scattering relative velocity (v). The a posteriori condition (Z/R)/v 2 <1, as an upper bound for heavy charges, is deduced for this applicability range from the comparative study performed

  18. In silico activity profiling reveals the mechanism of action of antimalarials discovered in a high-throughput screen

    Science.gov (United States)

    Plouffe, David; Brinker, Achim; McNamara, Case; Henson, Kerstin; Kato, Nobutaka; Kuhen, Kelli; Nagle, Advait; Adrián, Francisco; Matzen, Jason T.; Anderson, Paul; Nam, Tae-gyu; Gray, Nathanael S.; Chatterjee, Arnab; Janes, Jeff; Yan, S. Frank; Trager, Richard; Caldwell, Jeremy S.; Schultz, Peter G.; Zhou, Yingyao; Winzeler, Elizabeth A.

    2008-01-01

    The growing resistance to current first-line antimalarial drugs represents a major health challenge. To facilitate the discovery of new antimalarials, we have implemented an efficient and robust high-throughput cell-based screen (1,536-well format) based on proliferation of Plasmodium falciparum (Pf) in erythrocytes. From a screen of ≈1.7 million compounds, we identified a diverse collection of ≈6,000 small molecules comprised of >530 distinct scaffolds, all of which show potent antimalarial activity (antimalarials were identified in this screen, thus validating our approach. In addition, we identified many novel chemical scaffolds, which likely act through both known and novel pathways. We further show that in some cases the mechanism of action of these antimalarials can be determined by in silico compound activity profiling. This method uses large datasets from unrelated cellular and biochemical screens and the guilt-by-association principle to predict which cellular pathway and/or protein target is being inhibited by select compounds. In addition, the screening method has the potential to provide the malaria community with many new starting points for the development of biological probes and drugs with novel antiparasitic activities. PMID:18579783

  19. Fouling control mechanisms of demineralized water backwash: Reduction of charge screening and calcium bridging effects

    KAUST Repository

    Li, Sheng

    2011-12-01

    This paper investigates the impact of the ionic environment on the charge of colloidal natural organic matter (NOM) and ultrafiltration (UF) membranes (charge screening effect) and the calcium adsorption/bridging on new and fouled membranes (calcium bridging effect) by measuring the zeta potentials of membranes and colloidal NOM. Fouling experiments were conducted with natural water to determine whether the reduction of the charge screening effect and/or calcium bridging effect by backwashing with demineralized water can explain the observed reduction in fouling. Results show that the charge of both membranes and NOM, as measured by the zeta potential, became more negative at a lower pH and a lower concentration of electrolytes, in particular, divalent electrolytes. In addition, calcium also adsorbed onto the membranes, and consequently bridged colloidal NOM and membranes via binding with functional groups. The charge screening effect could be eliminated by flushing NOM and membranes with demineralized water, since a cation-free environment was established. However, only a limited amount of the calcium bridging connection was removed with demineralized water backwashes, so the calcium bridging effect mostly could not be eliminated. As demineralized water backwash was found to be effective in fouling control, it can be concluded that the reduction of the charge screening is the dominant mechanism for this. © 2011 Elsevier Ltd.

  20. Vaidya spacetime in massive gravity's rainbow

    Directory of Open Access Journals (Sweden)

    Yaghoub Heydarzade

    2017-11-01

    Full Text Available In this paper, we will analyze the energy dependent deformation of massive gravity using the formalism of massive gravity's rainbow. So, we will use the Vainshtein mechanism and the dRGT mechanism for the energy dependent massive gravity, and thus analyze a ghost free theory of massive gravity's rainbow. We study the energy dependence of a time-dependent geometry, by analyzing the radiating Vaidya solution in this theory of massive gravity's rainbow. The energy dependent deformation of this Vaidya metric will be performed using suitable rainbow functions.

  1. Massive Gravity

    OpenAIRE

    de Rham, Claudia

    2014-01-01

    We review recent progress in massive gravity. We start by showing how different theories of massive gravity emerge from a higher-dimensional theory of general relativity, leading to the Dvali–Gabadadze–Porrati model (DGP), cascading gravity, and ghost-free massive gravity. We then explore their theoretical and phenomenological consistency, proving the absence of Boulware–Deser ghosts and reviewing the Vainshtein mechanism and the cosmological solutions in these models. Finally, we present alt...

  2. Galileon cosmology

    International Nuclear Information System (INIS)

    Chow, Nathan; Khoury, Justin

    2009-01-01

    We study the cosmology of a galileon scalar-tensor theory, obtained by covariantizing the decoupling Lagrangian of the Dvali-Gabadadze-Poratti (DGP) model. Despite being local in 3+1 dimensions, the resulting cosmological evolution is remarkably similar to that of the full 4+1-dimensional DGP framework, both for the expansion history and the evolution of density perturbations. As in the DGP model, the covariant galileon theory yields two branches of solutions, depending on the sign of the galileon velocity. Perturbations are stable on one branch and ghostlike on the other. An interesting effect uncovered in our analysis is a cosmological version of the Vainshtein screening mechanism: at early times, the galileon dynamics are dominated by self-interaction terms, resulting in its energy density being suppressed compared to matter or radiation; once the matter density has redshifted sufficiently, the galileon becomes an important component of the energy density and contributes to dark energy. We estimate conservatively that the resulting expansion history is consistent with the observed late-time cosmology, provided that the scale of modification satisfies r c > or approx. 15 Gpc.

  3. Colour screening and quark confinement

    International Nuclear Information System (INIS)

    Mack, G.

    1978-01-01

    It is proposed that in quantum chromodynamics the colour charge of gluons and of anything with zero triality is screened by a dynamic Higgs mechanism with Higgs scalars made out of gluons, but the center Z 3 of the gauge group SU(3) is left unbroken, and single quarks, which have nonzero triality, are not screened. Long range forces between them persist therefore. Given that the Higgs mechanism produces a mass gap, the most favourable configuration of field lines between e.g., quark and antiquark will be in strings analogous to magnetic field lines in a superconductor. The string confine the quarks. The screening mechanism, on the other hand, produces not only the mass gap (which leads to string formation) but is also responsible for saturation of forces, i.e. absence of bound states of six quarks, etc. (Auth.)

  4. Colour screening and quark confinement

    International Nuclear Information System (INIS)

    Mack, G.

    1978-03-01

    It is proposed that in Quantum Chromodynamics the colour charge of gluons and of anything with zero triality is screened by a dynamical Higgs mechanism with Higgs scalars made out of gluons. The center Z 3 of the gauge group SU(3) is left unbroken in this way, and single quarks, which have nonzero triality, cannot be screened. Long range forces between them persist therefore. Given that the Higgs mechanism produces a mass gap, the most favorable configuration of field lines between e.g. quark and antiquark will be in strings analogous to magnetic field lines in a superconductor. The strings confine the quarks. The screening mechanism, on the other hand, produces not only the mass gap (which leads to string formation) but is also responsible for saturation of forces, i.e. absence of bound states of six quarks etc. (orig.) [de

  5. Influence of a screening navigation program on social inequalities in health beliefs about colorectal cancer screening.

    Science.gov (United States)

    Vallet, Fanny; Guillaume, Elodie; Dejardin, Olivier; Guittet, Lydia; Bouvier, Véronique; Mignon, Astrid; Berchi, Célia; Salinas, Agnès; Launoy, Guy; Christophe, Véronique

    2016-08-01

    The aim of the study was to test whether a screening navigation program leads to more favorable health beliefs and decreases social inequalities in them. The selected 261 noncompliant participants in a screening navigation versus a usual screening program arm had to respond to health belief measures inspired by the Protection Motivation Theory. Regression analyses showed that social inequalities in perceived efficacy of screening, favorable attitude, and perceived facility were reduced in the screening navigation compared to the usual screening program. These results highlight the importance of health beliefs to understand the mechanism of screening navigation programs in reducing social inequalities. © The Author(s) 2014.

  6. Inventions on GUI for Touch Sensitive Screens

    OpenAIRE

    Mishra, Umakant

    2014-01-01

    A touch sensitive screen displays the information on the screen and also receives the input by sensing a user's touch on the same screen. This mechanism facilitates system interaction directly through the screen without needing a mouse or keyboard. This method has the advantage to make the system compact by removing keyboard, mouse and similar interactive device. However there are certain difficulties to implement a touch screen interface. The display screens of portable devices are becoming ...

  7. Revealing molecular mechanisms by integrating high-dimensional functional screens with protein interaction data.

    Directory of Open Access Journals (Sweden)

    Angela Simeone

    2014-09-01

    Full Text Available Functional genomics screens using multi-parametric assays are powerful approaches for identifying genes involved in particular cellular processes. However, they suffer from problems like noise, and often provide little insight into molecular mechanisms. A bottleneck for addressing these issues is the lack of computational methods for the systematic integration of multi-parametric phenotypic datasets with molecular interactions. Here, we present Integrative Multi Profile Analysis of Cellular Traits (IMPACT. The main goal of IMPACT is to identify the most consistent phenotypic profile among interacting genes. This approach utilizes two types of external information: sets of related genes (IMPACT-sets and network information (IMPACT-modules. Based on the notion that interacting genes are more likely to be involved in similar functions than non-interacting genes, this data is used as a prior to inform the filtering of phenotypic profiles that are similar among interacting genes. IMPACT-sets selects the most frequent profile among a set of related genes. IMPACT-modules identifies sub-networks containing genes with similar phenotype profiles. The statistical significance of these selections is subsequently quantified via permutations of the data. IMPACT (1 handles multiple profiles per gene, (2 rescues genes with weak phenotypes and (3 accounts for multiple biases e.g. caused by the network topology. Application to a genome-wide RNAi screen on endocytosis showed that IMPACT improved the recovery of known endocytosis-related genes, decreased off-target effects, and detected consistent phenotypes. Those findings were confirmed by rescreening 468 genes. Additionally we validated an unexpected influence of the IGF-receptor on EGF-endocytosis. IMPACT facilitates the selection of high-quality phenotypic profiles using different types of independent information, thereby supporting the molecular interpretation of functional screens.

  8. Protecting the axion with local baryon number

    Science.gov (United States)

    Duerr, Michael; Schmidt-Hoberg, Kai; Unwin, James

    2018-05-01

    The Peccei-Quinn (PQ) solution to the Strong CP Problem is expected to fail unless the global symmetry U(1)PQ is protected from Planck-scale operators up to high mass dimension. Suitable protection can be achieved if the PQ symmetry is an automatic consequence of some gauge symmetry. We highlight that if baryon number is promoted to a gauge symmetry, the exotic fermions needed for anomaly cancellation can elegantly provide an implementation of the Kim-Shifman-Vainshtein-Zakharov 'hidden axion' mechanism with a PQ symmetry protected from Planck-scale physics.

  9. Screening vector field modifications of general relativity

    International Nuclear Information System (INIS)

    Beltrán Jiménez, Jose; Delvas Fróes, André Luís; Mota, David F.

    2013-01-01

    A screening mechanism for conformal vector–tensor modifications of general relativity is proposed. The conformal factor depends on the norm of the vector field and makes the field to vanish in high dense regions, whereas drives it to a non-null value in low density environments. Such process occurs due to a spontaneous symmetry breaking mechanism and gives rise to both the screening of fifth forces as well as Lorentz violations. The cosmology and local constraints are also computed

  10. SUPER-screening

    Energy Technology Data Exchange (ETDEWEB)

    Brax, Philippe, E-mail: Philippe.Brax@cea.fr [Institut de Physique Theorique, CEA, IPhT, CNRS, URA 2306, F-91191Gif/Yvette Cedex (France); Davis, Anne-Christine, E-mail: A.C.Davis@damtp.cam.ac.uk [DAMTP, Centre for Mathematical Sciences, University of Cambridge, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Sakstein, Jeremy, E-mail: J.A.Sakstein@damtp.cam.ac.uk [DAMTP, Centre for Mathematical Sciences, University of Cambridge, Wilberforce Road, Cambridge CB3 0WA (United Kingdom)

    2013-02-26

    We present a framework for embedding scalar–tensor models of screened modified gravity such as chameleons, symmetrons and environmental dilatons into global supersymmetry. This achieved by secluding the dark sector from both the observable and supersymmetry breaking sectors. We examine the resulting supersymmetric features in a model-independent manner and find that, when the theory follows from an underlying supergravity, the mediation of supersymmetry breaking to the dark sector induces a soft mass for the scalar of order the gravitino mass. This is enough to forbid the construction of supersymmetric symmetrons and ensures that when other screening mechanisms operate, no object in the Universe is unscreened thereby precluding any observable signatures. In view of a possible origin of modified gravity within fundamental physics, we find that only no-scale models can circumvent these features. We also present a novel mechanism where the coupling of the scalar to two other scalars charged under U(1) can dynamically generate a small cosmological constant at late times in the form of a Fayet–Iliopoulos term.

  11. Identification of protein kinase C activation as a novel mechanism for RGS2 protein upregulation through phenotypic screening of natural product extracts.

    Science.gov (United States)

    Raveh, Avi; Schultz, Pamela J; Aschermann, Lauren; Carpenter, Colleen; Tamayo-Castillo, Giselle; Cao, Shugeng; Clardy, Jon; Neubig, Richard R; Sherman, David H; Sjögren, Benita

    2014-10-01

    Biochemical high-throughput screening is widely used in drug discovery, using a variety of small molecule libraries. However, broader screening strategies may be more beneficial to identify novel biologic mechanisms. In the current study we used a β-galactosidase complementation method to screen a selection of microbial-derived pre-fractionated natural product extracts for those that increase regulator of G protein signaling 2 (RGS2) protein levels. RGS2 is a member of a large family of proteins that all regulate signaling through G protein-coupled receptors (GPCRs) by accelerating GTPase activity on active Gα as well as through other mechanisms. RGS2(-/-) mice are hypertensive, show increased anxiety, and are prone to heart failure. RGS2 has a very short protein half-life due to rapid proteasomal degradation, and we propose that enhancement of RGS2 protein levels could be a beneficial therapeutic strategy. Bioassay-guided fractionation of one of the hit strains yielded a pure compound, Indolactam V, a known protein kinase C (PKC) activator, which selectively increased RGS2 protein levels in a time- and concentration-dependent manner. Similar results were obtained with phorbol 12-myristate 13-acetate as well as activation of the Gq-coupled muscarinic M3 receptor. The effect on RGS2 protein levels was blocked by the nonselective PKC inhibitor Gö6983 (3-[1-[3-(dimethylamino)propyl]-5-methoxy-1H-indol-3-yl]-4-(1H-indol-3-yl)-1H-pyrrole-2,5-dione), the PKCβ-selective inhibitor Ruboxastaurin, as well as small interfering RNA-mediated knockdown of PKCβ. Indolactam V-mediated increases in RGS2 protein levels also had functional effects on GPCR signaling. This study provides important proof-of-concept for our screening strategy and could define a negative feedback mechanism in Gq/Phospholipase C signaling through RGS2 protein upregulation. Copyright © 2014 by The American Society for Pharmacology and Experimental Therapeutics.

  12. Why did soft drink consumption decrease but screen time not? Mediating mechanisms in a school-based obesity prevention program

    OpenAIRE

    Chin A Paw, M.J.M.; Singh, A.S.; Brug, J.; Mechelen, van, W.

    2008-01-01

    Abstract Objectives This paper aims to identify the mediating mechanisms of a school-based obesity prevention program (DOiT). Methods The DOiT-program was implemented in Dutch prevocational secondary schools and evaluated using a controlled, cluster-randomised trial (September 2003 to May 2004). We examined mediators of effects regarding (1) consumption of sugar containing beverages (SCB); (2) consumption of high caloric snacks; (3) screen-viewing behaviour; and (4) active commuting to school...

  13. Quarkonium suppression: Gluonic dissociation vs. colour screening

    Indian Academy of Sciences (India)

    mechanism comes into play for the initial conditions taken from the self screened parton cascade model in these studies. Keywords. Quark gluon plasma; J ψ; suppression; dissociation; colour screening. PACS No. 12.38.M. 1. Introduction. The last two decades have seen hectic activity towards identifying unique signatures ...

  14. Nine Different Chemical Species and Action Mechanisms of Pancreatic Lipase Ligands Screened Out from Forsythia suspensa Leaves All at One Time.

    Science.gov (United States)

    Chen, Tinggui; Li, Yayun; Zhang, Liwei

    2017-05-12

    It is difficult to screen out as many active components as possible from natural plants all at one time. In this study, subfractions of Forsythia suspensa leaves were firstly prepared; then, their inhibitive abilities on pancreatic lipase were tested; finally, the highest inhibiting subfraction was screened by self-made immobilized pancreatic lipase. Results showed that nine ligands, including eight inhibitors and one promotor, were screened out all at one time. They were three flavonoids (rutin, IC 50 : 149 ± 6.0 μmol/L; hesperidin, 52.4 μmol/L; kaempferol-3- O -rutinoside, isolated from F. suspensa leaves for the first time, IC 50 notably reached 2.9 ± 0.5 μmol/L), two polyphenols (chlorogenic acid, 3150 ± 120 μmol/L; caffeic acid, 1394 ± 52 μmol/L), two lignans (phillyrin, promoter; arctigenin, 2129 ± 10.5 μmol/L), and two phenethyl alcohol (forsythiaside A, 2155 ± 8.5 μmol/L; its isomer). Their action mechanisms included competitive inhibition, competitive promotion, noncompetitive inhibition, and uncompetitive inhibition. In sum, using the appropriate methods, more active ingredients can be simply and quickly screened out all at one time from a complex natural product system. In addition, F. suspensa leaves contain numerous inhibitors of pancreatic lipase.

  15. Screening Resonances In Plasmas

    International Nuclear Information System (INIS)

    Winkler, P.

    1998-01-01

    When it was suggested that a new recombination mechanism (Resonant Radiative Recombination (RRR)) which, based on very general physical arguments, should happen in dense plasmas and promises to provide useful information for the local temperature and density diagnostics of plasmas, they assumed the existence of screening resonances. For model potentials the existence of screening resonances has been demonstrated beyond reasonable doubt in a number of calculations. The key question, how well those potentials describe the dominant effects of a real plasma remains open. The relation of theoretical predictions to experimentally measurable effects is an important issue at the present stage of their research. In particular, RRR is expected to account for enhanced recombination rates of low energetic electrons with their ions, since the first stage is the resonant capture of a slow electron by an atom or ion. The mechanism that traps an electron is a combination of complicated many-body interactions of the ions and electrons. For clarity they start here, however, with a discussion in terms of local potential traps the shapes of which are determined predominantly and in an average way by two factors: the degree of screening present at the ionic site and the degree of short-range order in the immediate neighborhood of this ion

  16. Screened Coulomb interactions in metallic alloys. I. Universal screening in the atomic-sphere approximation

    DEFF Research Database (Denmark)

    Ruban, Andrei; Skriver, Hans Lomholt

    2002-01-01

    We have used the locally self-consistent Green's-function (LSGF) method in supercell calculations to establish the distribution of the net charges assigned to the atomic spheres of the alloy components in metallic alloys with different compositions and degrees of order. This allows us to determine......-site local interaction zone. We demonstrate that the basic mechanism that governs the charge distribution is the screening of the net charges of the alloy components that makes the direct Coulomb interactions short ranged. In the atomic-sphere approximation, this screening appears to be almost independent...

  17. Cervical cancer screening policies and coverage in Europe

    DEFF Research Database (Denmark)

    Anttila, Ahti; von Karsa, Lawrence; Aasmaa, Auni

    2009-01-01

    with education, training and communication among women, medical professionals and authorities are required, accordingly. The study indicates that, despite substantial efforts, the recommendations of the Council of the EU on organised population-based screening for cervical cancer are not yet fulfilled. Decision......The aim of the study was to compare current policy, organisation and coverage of cervical cancer screening programmes in the European Union (EU) member states with European and other international recommendations. According to the questionnaire-based survey, there are large variations in cervical...... cancer screening policies and inadequacies in the key organisational elements of the programme such as registration and monitoring required for quality-assurance and fail-safe mechanisms. Based on data from available screening registers, coverage of the screening test taken within the population...

  18. Relativistic stars in degenerate higher-order scalar-tensor theories after GW170817

    Science.gov (United States)

    Kobayashi, Tsutomu; Hiramatsu, Takashi

    2018-05-01

    We study relativistic stars in degenerate higher-order scalar-tensor theories that evade the constraint on the speed of gravitational waves imposed by GW170817. It is shown that the exterior metric is given by the usual Schwarzschild solution if the lower order Horndeski terms are ignored in the Lagrangian and a shift symmetry is assumed. However, this class of theories exhibits partial breaking of Vainshtein screening in the stellar interior and thus modifies the structure of a star. Employing a simple concrete model, we show that for high-density stars the mass-radius relation is altered significantly even if the parameters are chosen so that only a tiny correction is expected in the Newtonian regime. We also find that, depending on the parameters, there is a maximum central density above which solutions cease to exist.

  19. Vortex Ring Interaction with a Heated Screen

    Science.gov (United States)

    Smith, Jason; Krueger, Paul S.

    2008-11-01

    Previous examinations of vortex rings impinging on porous screens has shown the reformation of the vortex ring with a lower velocity after passing through the screen, the creation of secondary vortices, and mixing. A heated screen could, in principle, alter the vortex-screen interaction by changing the local liquid viscosity and density. In the present investigation, a mechanical piston-cylinder vortex ring generator was used to create vortex rings in an aqueous sucrose solution. The rings impinged on a screen of horizontal wires that were heated using electrical current. The flow was visualized with food color and video imaging. Tests with and without heat were conducted at a piston stroke-to-jet diameter ratio of 4 and a jet Reynolds number (Re) of 1000. The vortex rings slowed after passing through the screen, but in tests with heat, they maintained a higher fraction of their before-screen velocity due to reduction in fluid viscosity near the wires. In addition, small ``fingers'' that developed on the front of the vortex rings as they passed through the screen exhibited positive buoyancy effects in the heated case.

  20. Mechanisms of Parental supervision over children’s use of new screens

    Directory of Open Access Journals (Sweden)

    Lic. José Antonio Gabelas Barroso

    2008-01-01

    Full Text Available New screens (the Internet, videogames and cell phones, together with traditional TV, conform a first-order socialising agent for kids, adolescents and youngsters. Given the wide range of contents displayed through these media, it seems reasonable to raise the question of whether the less experienced and infant users have access to any safe guidance in this field. This paper presents the results of a survey on parent control over how their children make use of these media. It particularly focuses on the specific motivations underlying the involvement of the youngest generations in their everyday contact with each specific interactive media and the impact that entertainment, education and information provided through the new screens has on the habitual user. Pivotal in this analysis is the parents’ concern about the contents and the frequency of their children’s exposure.

  1. A mechanism misregulating p27 in tumors discovered in a functional genomic screen.

    Directory of Open Access Journals (Sweden)

    Carrie M Garrett-Engele

    2007-12-01

    Full Text Available The cyclin-dependent kinase inhibitor p27(KIP1 is a tumor suppressor gene in mice, and loss of p27 protein is a negative prognostic indicator in human cancers. Unlike other tumor suppressors, the p27 gene is rarely mutated in tumors. Therefore misregulation of p27, rather than loss of the gene, is responsible for tumor-associated decreases in p27 protein levels. We performed a functional genomic screen in p27(+/- mice to identify genes that regulate p27 during lymphomagenesis. This study demonstrated that decreased p27 expression in tumors resulted from altered transcription of the p27 gene, and the retroviral tagging strategy enabled us to pinpoint relevant transcription factors. inhibitor of DNA binding 3 (Id3 was isolated and validated as a transcriptional repressor of p27. We further demonstrated that p27 was a downstream target of Id3 in src-family kinase Lck-driven thymic lymphomagenesis and that p27 was an essential regulator of Lck-dependent thymic maturation during normal T-cell development. Thus, we have identified and characterized transcriptional repression of p27 by Id3 as a new mechanism decreasing p27 protein in tumors.

  2. Upgrade Of The ESRF Fluorescent Screen Monitors

    CERN Document Server

    Scheidt, K

    2003-01-01

    The ESRF injector system contains 23 Fluorescent Screen monitors: 4 in the TL-1 transferline (200 MeV), 8 in the Booster, and 11 in the TL-2 transferline (6 GeV). They are based on Chromium doped Alumina screens that are pneumatically inserted at 45o angle in the beam path with an optical system, at 90o angle, collecting and focusing the emitted light onto a low-cost CCD camera with standard 75Ω video output. Serving mainly alignment purposes in the past 10 years, the present upgrade aims at a 200 μm fwhm resolution for beam-size and profile measurements. The particularity of the Alumina screen not in vacuum but in atmosphere will be explained. Details of the mechanics, the optic system and a cost-efficient way of light flux adjustment will be given. The analysis of the factors determining the ultimate spatial resolution will show that it is dominated by the screen characteristics. Results obtained with different screen material will be presented.

  3. Finite element simulation of impact response of wire mesh screens

    Directory of Open Access Journals (Sweden)

    Wang Caizheng

    2015-01-01

    Full Text Available In this paper, the response of wire mesh screens to low velocity impact with blunt objects is investigated using finite element (FE simulation. The woven wire mesh is modelled with homogeneous shell elements with equivalent smeared mechanical properties. The mechanical behaviour of the woven wire mesh was determined experimentally with tensile tests on steel wire mesh coupons to generate the data for the smeared shell material used in the FE. The effects of impacts with a low mass (4 kg and a large mass (40 kg providing the same impact energy are studied. The joint between the wire mesh screen and the aluminium frame surrounding it is modelled using contact elements with friction between the corresponding elements. Damage to the screen of different types compromising its structural integrity, such as mesh separation and pulling out from the surrounding frame is modelled. The FE simulation is validated with results of impact tests conducted on woven steel wire screen meshes.

  4. Providing floating capabilities in latest-generation sand screens

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, E.G.; Coronado, M.P. [Society of Petroleum Engineers, Richardson, TX (United States)]|[Baker Hughes, Houston, TX (United States)

    2008-10-15

    Alternative production methods are needed for the massive reserves located in the bitumen region of Canada's tar sands. The area has over 100 installations of sand screens/slotted liners in both injection and production legs using steam-assisted gravity drainage (SAGD) technology. Multiple wells must be drilled from a single pad because of the sensitive nature of the environment. With significant depths of these wells, a floating sand screen provides assurance that the sand screen will reach the desired depth. Paraffin is generally used to plug the flow access of the screen during installation. This paper discussed a new technology that has been developed to allow for sand screen installations without relying on paraffin wax to withstand differential pressure. The new technology uses a hydro-mechanical valving system incorporated into the screen design to temporarily close off the screen while being run in the hole. The paper described how the technology could provide a reliable, time-saving solution for SAGD installations when floating sand control screens are needed. The paper discussed current technology and its limitations, sand screen installation, screen design for floating applications, and additional applications. It was concluded that this technology solution provides a unique alternative to the methods currently used to install sand screens with SAGD technology in the fast growing Canadian market for bitumen recovery. 2 refs., 5 figs.

  5. Screening for Cd-Safe Cultivars of Chinese Cabbage and a Preliminary Study on the Mechanisms of Cd Accumulation

    Directory of Open Access Journals (Sweden)

    Jingjie Wang

    2017-04-01

    Full Text Available With the rapid progress of industrialization, the effects of environmental contamination on plant toxicity, and subsequently on human health, is a growing concern. For example, the heavy metal pollution of soil such as that caused by cadmium (Cd is a serious threat. Therefore, screening for pollution-safe edible plants is an essential approach for growing plants under heavy metal-contaminated soils. In the current study, 35 Chinese cabbage (Brassica pekinensis L. cultivars were selected with the aim of screening for Cd-safe cultivars (CSCs, analyzing their safety, and exploring the mechanism of Cd accumulation. Our field-culture experiments revealed that the Cd content in the edible parts of the cultivars were varied and were determined to possibly be CSCs. Hydroponics experiments were used to simulate six different degrees of soil contamination (high and low Cd concentrations on possible CSCs. The results indicated a significant difference (p < 0.05 in Cd concentration in the cultivars, and verified the safety of these possible CSCs. The analyses of the transport coefficient and expression levels showed that the differences in Cd accumulation among the Chinese cabbage cultivars were related to the expression of genes involved in absorption and transport rather than a root-to-shoot translocation limitation.

  6. Keuringspanele ("Screening Panels") as Gepaste ...

    African Journals Online (AJOL)

    In this particular article attention is paid to screening panels as pre-trial mechanism with the exclusive purpose to select malpractice disputes, discourage unfounded disputes and to encourage an early settlement in case of a prima facie case. Several objections have been raised by critics in this regard, for instance, ...

  7. Parameterised post-Newtonian expansion in screened regions

    Science.gov (United States)

    McManus, Ryan; Lombriser, Lucas; Peñarrubia, Jorge

    2017-12-01

    The parameterised post-Newtonian (PPN) formalism has enabled stringent tests of static weak-field gravity in a theory-independent manner. Here we incorporate screening mechanisms of modified gravity theories into the framework by introducing an effective gravitational coupling and defining the PPN parameters as functions of position. To determine these functions we develop a general method for efficiently performing the post-Newtonian expansion in screened regimes. For illustration, we derive all the PPN functions for a cubic galileon and a chameleon model. We also analyse the Shapiro time delay effect for these two models and find no deviations from General Relativity insofar as the signal path and the perturbing mass reside in a screened region of space.

  8. Expanded newborn screening: social and ethical issues.

    Science.gov (United States)

    Dhondt, Jean-Louis

    2010-10-01

    Newborn screening and genetic testing have expanded rapidly in the last decade with the advent of multiplex (e.g., tandem mass spectrometry) and/or DNA technologies. However, screening panels include a large number of disorders, which may not meet all of the traditional screening criteria, established in late 1960s, and used for years to justify screening programs. After a period of expansion driven by technological advances, many reports have reconsidered the justification of expanded programs. Many factors have contributed to test-panel discrepancies between countries. The test-panel review methodology, the way health benefits are weighed against harms, and the socioeconomic-political environment all play a role. Expansion of screening also requires reconsideration of the infrastructure (ideally, in the context of national plans for rare diseases) to support testing, counselling, education, treatment, and follow-up. Consequently, economic aspects cannot be ignored and can be a limitation for expansion. New ethical questions have emerged: risks of discrimination or stigmatization, respect of the autonomy of persons to make decisions, parental anxiety resulting from a false positive test (especially when reporting to parents screening results for untreatable conditions identified as by-products of screening), etc. For disorders where there is not yet confirmation of benefit, it may be prudent to recommend pilot screening and to have a mechanism that can be used to adapt or even to stop a program.

  9. Charge Screening in a Charged Condensate

    International Nuclear Information System (INIS)

    Gabadadze, Gregory; Rosen, Rachel A.

    2009-01-01

    We consider a highly dense system of helium-4 nuclei and electrons in which the helium-4 nuclei have condensed. We present the condensation mechanism in the framework of low energy effective field theory and discuss the screening of electric charge in the condensate.

  10. The shape dependence of chameleon screening

    Science.gov (United States)

    Burrage, Clare; Copeland, Edmund J.; Moss, Adam; Stevenson, James A.

    2018-01-01

    Chameleon scalar fields can screen their associated fifth forces from detection by changing their mass with the local density. These models are an archetypal example of a screening mechanism, and have become an important target for both cosmological surveys and terrestrial experiments. In particular there has been much recent interest in searching for chameleon fifth forces in the laboratory. It is known that the chameleon force is less screened around non-spherical sources, but only the field profiles around a few simple shapes are known analytically. In this work we introduce a numerical code that solves for the chameleon field around arbitrary shapes with azimuthal symmetry placed in a spherical vacuum chamber. We find that deviations from spherical symmetry can increase the chameleon acceleration experienced by a test particle, and that the least screened objects are those which minimize some internal dimension. For the shapes considered in this work, keeping the mass, density and background environment fixed, the accelerations due to the source varied by a factor of ~ 3.

  11. Screens

    OpenAIRE

    2016-01-01

    This Sixth volume in the series The Key Debates. Mutations and Appropriations in European Film Studies investigates the question of screens in the context both of the dematerialization due to digitalization and the multiplication of media screens. Scholars offer various infomations and theories of topics such as the archeology of screen, film and media theories, contemporary art, pragmatics of new ways of screening (from home video to street screening).

  12. A microscale protein NMR sample screening pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo; Swapna, G. V. T.; Huang, Yuanpeng J.; Aramini, James M. [State University of New Jersey, Center for Advanced Biotechnology and Medicine, Department of Molecular Biology and Biochemistry, Rutgers (United States); Anklin, Clemens [Bruker Biospin Corporation (United States); Conover, Kenith; Hamilton, Keith; Xiao, Rong; Acton, Thomas B.; Ertekin, Asli; Everett, John K.; Montelione, Gaetano T., E-mail: guy@cabm.rutgers.ed [State University of New Jersey, Center for Advanced Biotechnology and Medicine, Department of Molecular Biology and Biochemistry, Rutgers (United States)

    2010-01-15

    As part of efforts to develop improved methods for NMR protein sample preparation and structure determination, the Northeast Structural Genomics Consortium (NESG) has implemented an NMR screening pipeline for protein target selection, construct optimization, and buffer optimization, incorporating efficient microscale NMR screening of proteins using a micro-cryoprobe. The process is feasible because the newest generation probe requires only small amounts of protein, typically 30-200 {mu}g in 8-35 {mu}l volume. Extensive automation has been made possible by the combination of database tools, mechanization of key process steps, and the use of a micro-cryoprobe that gives excellent data while requiring little optimization and manual setup. In this perspective, we describe the overall process used by the NESG for screening NMR samples as part of a sample optimization process, assessing optimal construct design and solution conditions, as well as for determining protein rotational correlation times in order to assess protein oligomerization states. Database infrastructure has been developed to allow for flexible implementation of new screening protocols and harvesting of the resulting output. The NESG micro NMR screening pipeline has also been used for detergent screening of membrane proteins. Descriptions of the individual steps in the NESG NMR sample design, production, and screening pipeline are presented in the format of a standard operating procedure.

  13. [Screening of anti-aging active ingredients and mechanism analysis based on molecular docking technology].

    Science.gov (United States)

    Du, Ran-Feng; Zhang, Xiao-Hua; Ye, Xiao-Tong; Yu, Wen-Kang; Wang, Yun

    2016-07-01

    Dampness evil is the source of all diseases, which is easy to cause disease and promote aging, while aging could also promote the occurence and development of diseases. In this paper, the relationship between the dampness evil and aging would be discussed, to find the anti-aging active ingredients in traditional Chinese medicine (TCM), and analyze the anti-aging mechanism of dampness eliminating drug. Molecular docking technology was used, with aging-related mammalian target of rapamycin as the docking receptors, and chemical components of Fuling, Sangzhi, Mugua, Yiyiren and Houpo as the docking molecules, to preliminarily screen the anti-aging active ingredients in dampness eliminating drug. Through the comparison with active drugs already on the market (temsirolimus and everolimus), 12 kinds of potential anti-aging active ingredients were found, but their drug gability still needs further study. The docking results showed that various components in the dampness eliminating drug can play anti-aging activities by acting on mammalian target of rapamycin. This result provides a new thought and direction for the method of delaying aging by eliminating dampness. Copyright© by the Chinese Pharmaceutical Association.

  14. A comparison of the screening performance of braided coaxial and triaxial cables

    International Nuclear Information System (INIS)

    Fowler, E.P.

    1975-03-01

    The screening performance of a coaxial screened circuit is derived from measurements of the surface transfer impedance, capacitive coupling and conductor eccentricity on short lengths of cable. This is then extended to a triaxial screen considering all the ways the two screens can be connected. Comparison of calculated performance and measured results on a 10m length show that the mechanisms of coupling interact to make triaxial cable screening worse than expected and, in fact, frequently no better than a coaxial cable. The use of superscreened cables is found to overcome all the problems known in triaxial cables. (author)

  15. Screening of electrocatalytic materials for hydrogen evolution

    DEFF Research Database (Denmark)

    Björketun, Mårten; Bondarenko, Alexander S.; Abrams, Billie

    2010-01-01

    A general scheme for high-throughput screening of electrocatalysts is presented. By systematically exploiting a collection of theoretical and experimental materials databases, supplemented with quantum mechanical calculations, it locates systems that meet a set of pre-imposed selection criteria...

  16. An Xpert screen to identify carbapenemases

    Directory of Open Access Journals (Sweden)

    Mubin Kazi

    2016-01-01

    Full Text Available To prevent the spread of carbapenemases-producing Enterobacteriaceae (CPE active surveillance, contact isolation and cohorting infected patients should be practiced. Rectal swabs for the Xpert MDRO-assay of 32 patients were included. 71.85% were positive for targets incorporated into the MDRO-assay; whereas 28% were phenotypically not CRE and Xpert negative (9.37% had different mechanism [bla OXA]. The assay identified 59.3%, 9.37% and 3.1% as bla NDM, bla NDM+VIM and bla VIM, respectively. The assay is a screening test that identifies CPE harbouring organism within an hour and can be installed at tertiary-care facilities to screen colonized patients.

  17. The design of disengaging mechanism of radix pseudostellariae and soil

    Science.gov (United States)

    Xiao, Shungen; Song, Mengmeng; Chen, Chanwei

    2017-12-01

    With the continuous development of the scale of the cultivation of the radix pseudostellariae, the traditional separation mode cannot adapt to the mass production of the crown prince, and the existing manual separation mode is of great labor intensity and low degree of mechanization. Therefore, it is necessary to design a disengaging mechanism of radix pseudostellariae and soil on the basis of the design principle of modern agricultural machinery. According to the physical characteristics and growing environment of radix pseudostellariae, a drum-type separating component is presented, and the drum screen separating mechanism and vibration mechanism of the disengaging mechanism are designed. In this paper, the movement rule and time of the mixture of radix pseudostellariae and soil are determined in the drum screen. Rotation speed of the drum screen is calculated, and the operation rules of the eccentric wheel in the vibration mechanism are summarized.

  18. Analysis on screening results of 2 203 premature infants with retinopathy

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2018-06-01

    Full Text Available AIM: To investigate the incidence and risk factors of retinopathy of prematurity(ROPin preterm infants. METHODS: The wide-field digital pediatric Retinal imaging system was used to screen 2 203 preterm infants with gestational age RESULTS: Totally 367 infants(621 eyeswere diagnosed as retinopathy among 2 203 premature infants and the incidence of ROP was 16.66%; 236 cases(399 eyesof ROP(26.61%were detected in 887 cases of premature infants in accord with screening standard of the Chinese Premature Retinopathy Screening Guidelines(2014, and 131 cases(222 eyesof ROP(9.95%was detected in 1 316 cases of premature infants outside the screening standard. In our research, the incidence of ROP was related with gestational age, birth weight, oxygen duration and mechanical ventilation. However, the relationship had not been found with artificial insemination, caesarean birth, gender, polyembryony, acute respiratory distress syndrome(ARDS, hypertensive disorders in pregnancy, gestational diabetes mellitus, intrauterine infection, intrauterine distress, premature rupture of membrane. The incidence of ROP was statistically significant between different gestational age groups, different birth weight groups and different oxygen groups(PCONCLUSION: The incidence of ROP is 16.66% in this study, and there is still a certain proportion outside the screening standard of the Chinese Premature Retinopathy Screening Guidelines(2014. Gestational age, birth weight, oxygen duration and mechanical ventilation are high risk factors for ROP.

  19. Depression Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Depression Screening (PHQ-9) - Instructions The following questions are ... this tool, there is also text-only version . Depression Screening - Manual Instructions The following questions are a ...

  20. Vortex-pair nucleation at defects: A mechanism for anomalous temperature dependence in the superconducting screening length

    International Nuclear Information System (INIS)

    Hebard, A.F.; Fiory, A.T.; Siegal, M.P.; Phillips, J.M.; Haddon, R.C.

    1991-01-01

    Low-field ac screening measurements on YBa 2 Cu 3 O 7-δ films and (BEDT-TTF) 2 Cu(SCN) 2 crystals [where BEDT-TTF is bis(ethylenedithio)tetrathiafulvalene], both thought to contain a high density of defects, reveal a diminution of screening and a common extrinsic temperature dependence of the screening length λ. Vortex-core pinning at the defects is shown to give a low-temperature T 2 power-law temperature dependence to λ that, in contrast to the exponential behavior expected from s-wave pairing, can be mistaken as evidence for lines or nodes of the energy gap on the Fermi surface

  1. Clinical and psychological effects of excessive screen time on children.

    Science.gov (United States)

    Domingues-Montanari, Sophie

    2017-04-01

    Over recent years, screen time has become a more complicated concept, with an ever-expanding variety of electronic media devices available throughout the world. Television remains the predominant type of screen-based activity among children. However, computer use, video games and ownership of devices, such as tablets and smart phones, are occurring from an increasingly young age. Screen time, in particular, television viewing, has been negatively associated with the development of physical and cognitive abilities, and positively associated with obesity, sleep problems, depression and anxiety. The physiological mechanisms that underlie the adverse health outcomes related to screen time and the relative contributions of different types of screen and media content to specific health outcomes are unclear. This review discusses the positive and negative effects of screen time on the physiological and psychological development of children. Furthermore, recommendations are offered to parents and clinicians. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  2. Approaches to virtual screening and screening library selection.

    Science.gov (United States)

    Wildman, Scott A

    2013-01-01

    The ease of access to virtual screening (VS) software in recent years has resulted in a large increase in literature reports. Over 300 publications in the last year report the use of virtual screening techniques to identify new chemical matter or present the development of new virtual screening techniques. The increased use is accompanied by a corresponding increase in misuse and misinterpretation of virtual screening results. This review aims to identify many of the common difficulties associated with virtual screening and allow researchers to better assess the reliability of their virtual screening effort.

  3. Thermo-mechanical screening tests to qualify beryllium pebble beds with non-spherical pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Reimann, Joerg, E-mail: joerg.reimann@partner.kit.edu [IKET, Karlsruhe Institute of Technology, Karlsruhe (Germany); Fretz, Benjamin [KBHF GmbH, Eggenstein-Leopoldshafen (Germany); Pupeschi, Simone [IAM, Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2015-10-15

    Highlights: • In present ceramic breeder blankets, pebble-shaped beryllium is used as a neutron multiplier. • Spherical pebbles are considered as the candidate material, however, non-spherical particles are of economic interest. • Thermo-mechanical pebble bed data do merely exist for non-spherical beryllium grades. • Uniaxial compression tests (UCTs), combined with the Hot Wire Technique (HWT) were used to measure the stress–strain relations and the thermal conductivity. • A small experimental set-up had to be used and a detailed 3D modelling was of prime importance. • Compared to spherical pebble beds, non-spherical pebble beds are generally softer and mainly the thermal conductivity is lower. - Abstract: In present ceramic breeder blankets, pebble-shaped beryllium is used as a neutron multiplier. Fairly spherical pebbles are considered as a candidate material, however, non-spherical particles are of economic interest because production costs are much lower. Yet, thermo-mechanical pebble bed data do merely exist for these beryllium grades, and the blanket relevant potential of these grades cannot be judged. Screening experiments were performed with three different grades of non-spherical beryllium pebbles, produced by different companies, accompanied by experiments with the reference beryllium pebble beds. Uniaxial compression tests (UCTs), combined with the Hot Wire Technique (HWT), were performed to measure both the stress–strain relation and the thermal conductivity, k, at different stress levels. Because of the limited amounts of the non-spherical materials, the experimental set-ups were small and a detailed 3D modelling was of prime importance in order to prove that the used design was appropriate. Compared to the pebble beds consisting of spherical pebbles, non-spherical pebble beds are generally softer (smaller stress for a given strain), and, mainly as a consequence of this, for a given strain value, the thermal conductivity is lower. This

  4. DG-AMMOS: a new tool to generate 3d conformation of small molecules using distance geometry and automated molecular mechanics optimization for in silico screening.

    Science.gov (United States)

    Lagorce, David; Pencheva, Tania; Villoutreix, Bruno O; Miteva, Maria A

    2009-11-13

    Discovery of new bioactive molecules that could enter drug discovery programs or that could serve as chemical probes is a very complex and costly endeavor. Structure-based and ligand-based in silico screening approaches are nowadays extensively used to complement experimental screening approaches in order to increase the effectiveness of the process and facilitating the screening of thousands or millions of small molecules against a biomolecular target. Both in silico screening methods require as input a suitable chemical compound collection and most often the 3D structure of the small molecules has to be generated since compounds are usually delivered in 1D SMILES, CANSMILES or in 2D SDF formats. Here, we describe the new open source program DG-AMMOS which allows the generation of the 3D conformation of small molecules using Distance Geometry and their energy minimization via Automated Molecular Mechanics Optimization. The program is validated on the Astex dataset, the ChemBridge Diversity database and on a number of small molecules with known crystal structures extracted from the Cambridge Structural Database. A comparison with the free program Balloon and the well-known commercial program Omega generating the 3D of small molecules is carried out. The results show that the new free program DG-AMMOS is a very efficient 3D structure generator engine. DG-AMMOS provides fast, automated and reliable access to the generation of 3D conformation of small molecules and facilitates the preparation of a compound collection prior to high-throughput virtual screening computations. The validation of DG-AMMOS on several different datasets proves that generated structures are generally of equal quality or sometimes better than structures obtained by other tested methods.

  5. [Preference on screening frequency and willingness-to-pay for multiple-cancer packaging screening programs in urban populations in China].

    Science.gov (United States)

    Zhu, J; Huang, H Y; Mao, A Y; Sun, Z X; Qiu, W Q; Lei, H K; Dong, P; Huang, J W; Bai, Y N; Sun, X J; Liu, G X; Wang, D B; Liao, X Z; Ren, J S; Guo, L W; Lan, L; Zhou, Q; Song, B B; Liu, Y Q; Du, L B; Zhu, L; Cao, R; Wang, J L; Mai, L; Ren, Y; Zhou, J Y; Sun, X H; Wu, S L; Qi, X; Lou, P A; Cai, B; Li, N; Zhang, K; He, J; Dai, M; Shi, J F

    2018-02-10

    Objective: From an actual cancer screening service demanders' perspective, we tried to understand the preference on screening frequency and willingness-to-pay for the packaging screening program on common cancers and to evaluate its long-term sustainability in urban populations in China. Methods: From 2012 to 2014, a multi-center cross-sectional survey was conducted among the actual screening participants from 13 provinces covered by the Cancer Screening Program in Urban China (CanSPUC). By face-to-face interview, information regarding to preference to screening frequency, willingness-to-pay for packaging screening program, maximum amount on payment and related reasons for unwillingness were investigated. Results: A total of 31 029 participants were included in this survey, with an average age as (55.2±7.5) years and median annual income per family as 25 000 Chinese Yuan. People's preference to screening frequency varied under different assumptions ( " totally free" and "self-paid" ). When the packaging screening was assumed totally free, 93.9% of residents would prefer to take the screening program every 1 to 3 years. However, the corresponding proportion dropped to 67.3% when assuming a self-paid pattern. 76.7% of the participants had the willingness-to-pay for the packaging screening, but only 11.2% of them would like to pay more than 500 Chinese Yuan (the expenditure of the particular packaging screening were about 1 500 Chinese Yuan). The remaining 23.3% of residents showed no willingness-to-pay, and the main reasons were unaffordable expenditure (71.7%) and feeling'no need'(40.4%). Conclusions: People who participated in the CanSPUC program generally tended to choose high-frequency packaging screening program, indicating the high potential acceptance for scale-up packaging screening, while it needs cautious assessments and rational guidance to the public. Although about seven in ten of the residents were willing to pay, the payment amount was limited

  6. Ellipticity Weakens Chameleon Screening

    OpenAIRE

    Burrage, Clare; Copeland, Edmund J.; Stevenson, James

    2014-01-01

    The chameleon mechanism enables a long range fifth force to be screened in dense environments when non-trivial self interactions of the field cause its mass to increase with the local density. To date, chameleon fifth forces have mainly been studied for spherically symmetric sources, however the non-linear self interactions mean that the chameleon responds to changes in the shape of the source differently to gravity. In this work we focus on ellipsoidal departures from spherical symmetry and ...

  7. AMMOS: A Software Platform to Assist in silico Screening

    Directory of Open Access Journals (Sweden)

    Lagorce D.

    2009-12-01

    Full Text Available Three software packages based on the common platform of AMMOS (Automated Molecular Mechanics Optimization tool for in silico Screening for assisting virtual ligand screening purposes have been recently developed. DG-AMMOS allows generation of 3D conformations of small molecules using distance geometry and molecular mechanics optimization. AMMOS_SmallMol is a package for structural refinement of compound collections that can be used prior to docking experiments. AMMOS_ProtLig is a package for energy minimization of protein-ligand complexes. It performs an automatic procedure for molecular mechanics minimization at different levels of flexibility - from rigid to fully flexible structures of both the ligand and the receptor. The packages have been tested on small molecules with a high structural diversity and proteins binding sites of completely different geometries and physicochemical properties. The platform is developed as an open source software and can be used in a broad range of in silico drug design studies.

  8. Mixed total screening for sulfur isotope

    International Nuclear Information System (INIS)

    Cui Bin; Zhao Lei; Zhan Zhaoyang; He Zhijun

    2003-01-01

    The research on modern economic geology indicates that most ore deposits formed with characters of multi-origin, multi-stage and multi-genesis. Quantificational research of Sulfur isotope origin is a difficult problem that puzzles Geochemists all along. So the formation process of an ore deposit can be taken as the mix or the superposition of multi totals, which can be described by the mathematics model of mixed total screening. In the study of mid-down Yangtze River and Dongpo ore field in Hunan province, the authors successfully applied the mathematics model of mixed total screening, quantificationally resolved the problem of Sulfur isotope origin and mineralizing matter origin, and found out the mineralizing mechanism. This is very valuable. (authors)

  9. Antimicrobial screening of Cichorium intybus seed extracts

    Directory of Open Access Journals (Sweden)

    Tauseef shaikh

    2016-11-01

    Full Text Available Medicinal plants play an important role in the field of natural products and human health care system. Chemical constituents present in the various parts of the plants can resist to parasitic attack by using several defense mechanisms. One such mechanism is the synthesis of antimicrobial compound. Cichorium intybus is one of the important medicinal plants which belong to Asteraceae family. In the present work, antimicrobial screening of C. intybus seed extract was studied by agar well diffusion assay by using aqueous and organic extracts. The pathogenic microorganisms tested include Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans and Escherichia coli. All the seed extracts showed antimicrobial activity against tested microorganisms whereas S. aureus was found to be most sensitive against aqueous extract and had the widest zone of inhibition. Ethyl acetate and ethanol extract were found to be significant against P. aeruginosa and S. aureus. The results obtained from antimicrobial screening scientifically support the effectiveness of the medicinal plant.

  10. Seventeen-years overview of breast cancer inside and outside screening in Denmark

    DEFF Research Database (Denmark)

    Domingo, Laia; Jacobsen, Katja Kemp; von Euler-Chelpin, My Catarina

    2013-01-01

    Background. Long-term data on breast cancer detection in mammography screening programs are warranted to better understand the mechanisms by which screening changes the breast cancer pattern in the population. We aimed to analyze 17 years of breast cancer detection rates inside and outside...... to women aged 50-69 years. We identified targeted, eligible, invited and participating women. We calculated screening detection and interval cancer rates for participants, and breast cancer incidence in non-screened women (= targeted women excluding participants) by biennial invitation rounds. Tumor...... characteristics were tabulated for each of the three groups of cancers. Results. Start of screening resulted in a prevalence peak in participants, followed by a decrease to a fairly stable detection rate in subsequent invitation rounds. A similar pattern was found for breast cancer incidence in non-screened women...

  11. Primary care colorectal cancer screening correlates with breast cancer screening: implications for colorectal cancer screening improvement interventions.

    Science.gov (United States)

    Weiss, Jennifer M; Pandhi, Nancy; Kraft, Sally; Potvien, Aaron; Carayon, Pascale; Smith, Maureen A

    2018-04-25

    National colorectal cancer (CRC) screening rates have plateaued. To optimize interventions targeting those unscreened, a better understanding is needed of how this preventive service fits in with multiple preventive and chronic care needs managed by primary care providers (PCPs). This study examines whether PCP practices of other preventive and chronic care needs correlate with CRC screening. We performed a retrospective cohort study of 90 PCPs and 33,137 CRC screening-eligible patients. Five PCP quality metrics (breast cancer screening, cervical cancer screening, HgbA1c and LDL testing, and blood pressure control) were measured. A baseline correlation test was performed between these metrics and PCP CRC screening rates. Multivariable logistic regression with clustering at the clinic-level estimated odds ratios and 95% confidence intervals for these PCP quality metrics, patient and PCP characteristics, and their relationship to CRC screening. PCP CRC screening rates have a strong correlation with breast cancer screening rates (r = 0.7414, p < 0.001) and a weak correlation with the other quality metrics. In the final adjusted model, the only PCP quality metric that significantly predicted CRC screening was breast cancer screening (OR 1.25; 95% CI 1.11-1.42; p < 0.001). PCP CRC screening rates are highly concordant with breast cancer screening. CRC screening is weakly concordant with cervical cancer screening and chronic disease management metrics. Efforts targeting PCPs to increase CRC screening rates could be bundled with breast cancer screening improvement interventions to increase their impact and success.

  12. More comprehensive discussion of CRC screening associated with higher screening.

    Science.gov (United States)

    Mosen, David M; Feldstein, Adrianne C; Perrin, Nancy A; Rosales, A Gabriella; Smith, David H; Liles, Elizabeth G; Schneider, Jennifer L; Meyers, Ronald E; Elston-Lafata, Jennifer

    2013-04-01

    Examine association of comprehensiveness of colorectal cancer (CRC) screening discussion by primary care physicians (PCPs) with completion of CRC screening. Observational study in Kaiser Permanente Northwest, a group-model health maintenance organization. A total of 883 participants overdue for CRC screening received an automated telephone call (ATC) between April and June 2009 encouraging CRC screening. Between January and March 2010, participants completed a survey on PCPs' discussion of CRC screening and patient beliefs regarding screening. receipt of CRC screening (assessed by electronic medical record [EMR], 9 months after ATC). Primary independent variable: comprehensiveness of CRC screening discussion by PCPs (7-item scale). Secondary independent variables: perceived benefits of screening (4-item scale assessing respondents' agreement with benefits of timely screening) and primary care utilization (EMR; 9 months after ATC). The independent association of variables with CRC screening was assessed with logistic regression. Average scores for comprehensiveness of CRC discussion and perceived benefits were 0.4 (range 0-1) and 4.0 (range 1-5), respectively. A total of 28.2% (n = 249) completed screening, 84% of whom had survey assessments after their screening date. Of screeners, 95.2% completed the fecal immunochemical test. More comprehensive discussion of CRC screening was associated with increased screening (odds ratio [OR] = 1.51, 95% confidence interval [CI] = 1.03-2.21). Higher perceived benefits (OR = 1.46, 95% CI = 1.13-1.90) and 1 or more PCP visits (OR = 5.82, 95% CI = 3.87-8.74) were also associated with increased screening. More comprehensive discussion of CRC screening was independently associated with increased CRC screening. Primary care utilization was even more strongly associated with CRC screening, irrespective of discussion of CRC screening.

  13. The screen character of the Whitetiger mountain filling to radioactivity waste disposal

    International Nuclear Information System (INIS)

    Shi Jianfang

    2003-01-01

    Safety disposal of radioactivity waste depends on geology protective screen and artificial protective screen. After disposal site is chosen, the effect of artificial protective screen appears very important. The smashing material of Whitetiger Mountain clay rock is selected as researching object. The method of combining soil mechanics with radiochemistry is adopted on the basis of many experiment of laboratory. The screen effect and mechanism of filling layer to radioactivity nuclide 90 Sr are discussed. Under the circumstance of filling layer composition, control effect of soil body construction to permeability and adsorption of filling protective screen layer are analysed. Synthesis evaluation model of filling protective screen layer is established. It is found that the filling belongs to high-liquids-clay. For filling with diameter equal or smaller than 2 millimeter, when the ρ d equal 1.73 g/cm 3 , the most equitable moving speed of 90 Sr in compaction filling is 4.5 x 10 -5 cm/min, the k equals 2.68 x10 -8 cm/s. For filling with diameter equal or smaller than 5 mm, when the ρ d equal 1.74 g/cm 3 , the most equitable moving speed of 90 Sr in compaction filling is 4.3 x 10 -5 cm/min, the k equals 6.1 x 10 -8 cm/s. (author)

  14. Mechanical behaviour of vacuum chambers and beam screens under quench conditions in dipole and quadrupole fields

    CERN Document Server

    Rathjen, C

    2002-01-01

    A method based on analytical formulas is described to calculate bending moments, stresses, and deformations of vacuum chambers and beam screens in dipole and in quadrupole fields during a magnet quench. Solutions are given for circular and racetrack shaped structures. Without the need of time consuming calculations the solutions enable a quick design and verification of vacuum chambers and beam screens.

  15. Self-acceleration in scalar-bimetric theories

    Science.gov (United States)

    Brax, Philippe; Valageas, Patrick

    2018-05-01

    force on small scales and decouples the local value of Newton constant from its cosmological value. This cannot be achieved by a quasistatic chameleon mechanism and requires going beyond the quasistatic regime and probably using derivative screenings, such as Kmouflage or Vainshtein screening, on small scales.

  16. DG-AMMOS: A New tool to generate 3D conformation of small molecules using Distance Geometry and Automated Molecular Mechanics Optimization for in silico Screening

    Directory of Open Access Journals (Sweden)

    Villoutreix Bruno O

    2009-11-01

    Full Text Available Abstract Background Discovery of new bioactive molecules that could enter drug discovery programs or that could serve as chemical probes is a very complex and costly endeavor. Structure-based and ligand-based in silico screening approaches are nowadays extensively used to complement experimental screening approaches in order to increase the effectiveness of the process and facilitating the screening of thousands or millions of small molecules against a biomolecular target. Both in silico screening methods require as input a suitable chemical compound collection and most often the 3D structure of the small molecules has to be generated since compounds are usually delivered in 1D SMILES, CANSMILES or in 2D SDF formats. Results Here, we describe the new open source program DG-AMMOS which allows the generation of the 3D conformation of small molecules using Distance Geometry and their energy minimization via Automated Molecular Mechanics Optimization. The program is validated on the Astex dataset, the ChemBridge Diversity database and on a number of small molecules with known crystal structures extracted from the Cambridge Structural Database. A comparison with the free program Balloon and the well-known commercial program Omega generating the 3D of small molecules is carried out. The results show that the new free program DG-AMMOS is a very efficient 3D structure generator engine. Conclusion DG-AMMOS provides fast, automated and reliable access to the generation of 3D conformation of small molecules and facilitates the preparation of a compound collection prior to high-throughput virtual screening computations. The validation of DG-AMMOS on several different datasets proves that generated structures are generally of equal quality or sometimes better than structures obtained by other tested methods.

  17. Why did soft drink consumption decrease but screen time not? Mediating mechanisms in a school-based obesity prevention program

    Directory of Open Access Journals (Sweden)

    Brug Johannes

    2008-08-01

    Full Text Available Abstract Objectives This paper aims to identify the mediating mechanisms of a school-based obesity prevention program (DOiT. Methods The DOiT-program was implemented in Dutch prevocational secondary schools and evaluated using a controlled, cluster-randomised trial (September 2003 to May 2004. We examined mediators of effects regarding (1 consumption of sugar containing beverages (SCB; (2 consumption of high caloric snacks; (3 screen-viewing behaviour; and (4 active commuting to school. To improve these behaviours the DOiT-program tried to influence the following potentially mediating variables: attitude, subjective norm, perceived behavioural control, and habit-strength. Results Both in boys (n = 418 and girls (n = 436 the DOiT-intervention reduced SCB consumption (between group difference in boys = -303.5 ml/day, 95% CI: -502.4;-104.5, between group difference in girls = -222.3 ml/day, 95% CI: -371.3;-73.2. The intervention did not affect the other examined behaviours. In girls, no intervention effect on hypothetical mediators was found nor evidence of any mediating mechanisms. Boys in intervention schools improved their attitude towards decreasing SCB consumption, while this behaviour became less of a habit. Indeed, attitude and habit strength were significant mediators of the DOiT-intervention's effect (4.5 and 3.8%, respectively on SCB consumption among boys. Conclusion Our findings imply that interventions aimed at EBRB-change should be gender-specific. Future studies aimed at reducing SCB consumption among boys should target attitude and habit strength as mediating mechanisms. Our study did not resolve the mediating mechanisms in girls. Trial registration International Standard Randomised Controlled Trial Number Register ISRCTN87127361

  18. Earthworm-Derived Pore-Forming Toxin Lysenin and Screening of Its Inhibitors

    Directory of Open Access Journals (Sweden)

    Neelanun Sukumwang

    2013-08-01

    Full Text Available Lysenin is a pore-forming toxin from the coelomic fluid of earthworm Eisenia foetida. This protein specifically binds to sphingomyelin and induces erythrocyte lysis. Lysenin consists of 297 amino acids with a molecular weight of 41 kDa. We screened for cellular signal transduction inhibitors of low molecular weight from microorganisms and plants. The purpose of the screening was to study the mechanism of diseases using the obtained inhibitors and to develop new chemotherapeutic agents acting in the new mechanism. Therefore, our aim was to screen for inhibitors of Lysenin-induced hemolysis from plant extracts and microbial culture filtrates. As a result, we isolated all-E-lutein from an extract of Dalbergia latifolia leaves. All-E-lutein is likely to inhibit the process of Lysenin-membrane binding and/or oligomer formation rather than pore formation. Additionally, we isolated tyrosylproline anhydride from the culture filtrate of Streptomyces as an inhibitor of Lysenin-induced hemolysis.

  19. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  20. An experience of qualified preventive screening: shiraz smart screening software.

    Science.gov (United States)

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  1. Transgenic Plants as Low-Cost Platform for Chemotherapeutic Drugs Screening

    Directory of Open Access Journals (Sweden)

    Daniele Vergara

    2015-01-01

    Full Text Available In this work we explored the possibility of using genetically modified Arabidopsis thaliana plants as a rapid and low-cost screening tool for evaluating human anticancer drugs action and efficacy. Here, four different inhibitors with a validated anticancer effect in humans and distinct mechanism of action were screened in the plant model for their ability to interfere with the cytoskeletal and endomembrane networks. We used plants expressing a green fluorescent protein (GFP tagged microtubule-protein (TUA6-GFP, and three soluble GFPs differently sorted to reside in the endoplasmic reticulum (GFPKDEL or to accumulate in the vacuole through a COPII dependent (AleuGFP or independent (GFPChi mechanism. Our results demonstrated that drugs tested alone or in combination differentially influenced the monitored cellular processes including cytoskeletal organization and endomembrane trafficking. In conclusion, we demonstrated that A. thaliana plants are sensitive to the action of human chemotherapeutics and can be used for preliminary screening of drugs efficacy. The cost-effective subcellular imaging in plant cell may contribute to better clarify drugs subcellular targets and their anticancer effects.

  2. A Drosophila Genome-Wide Screen Identifies Regulators of Steroid Hormone Production and Developmental Timing

    DEFF Research Database (Denmark)

    Thomas Danielsen, E.; E. Møller, Morten; Yamanaka, Naoki

    2016-01-01

    Steroid hormones control important developmental processes and are linked to many diseases. To systematically identify genes and pathways required for steroid production, we performed a Drosophila genome-wide in vivo RNAi screen and identified 1,906 genes with potential roles in steroidogenesis...... and developmental timing. Here, we use our screen as a resource to identify mechanisms regulating intracellular levels of cholesterol, a substrate for steroidogenesis. We identify a conserved fatty acid elongase that underlies a mechanism that adjusts cholesterol trafficking and steroidogenesis with nutrition...... and developmental programs. In addition, we demonstrate the existence of an autophagosomal cholesterol mobilization mechanism and show that activation of this system rescues Niemann-Pick type C1 deficiency that causes a disorder characterized by cholesterol accumulation. These cholesterol-trafficking mechanisms...

  3. A perturbative approach to the redshift space correlation function: beyond the Standard Model

    Science.gov (United States)

    Bose, Benjamin; Koyama, Kazuya

    2017-08-01

    We extend our previous redshift space power spectrum code to the redshift space correlation function. Here we focus on the Gaussian Streaming Model (GSM). Again, the code accommodates a wide range of modified gravity and dark energy models. For the non-linear real space correlation function used in the GSM we use the Fourier transform of the RegPT 1-loop matter power spectrum. We compare predictions of the GSM for a Vainshtein screened and Chameleon screened model as well as GR. These predictions are compared to the Fourier transform of the Taruya, Nishimichi and Saito (TNS) redshift space power spectrum model which is fit to N-body data. We find very good agreement between the Fourier transform of the TNS model and the GSM predictions, with <= 6% deviations in the first two correlation function multipoles for all models for redshift space separations in 50Mpch <= s <= 180Mpc/h. Excellent agreement is found in the differences between the modified gravity and GR multipole predictions for both approaches to the redshift space correlation function, highlighting their matched ability in picking up deviations from GR. We elucidate the timeliness of such non-standard templates at the dawn of stage-IV surveys and discuss necessary preparations and extensions needed for upcoming high quality data.

  4. A stretchable and screen-printable conductive ink for stretchable electronics

    Science.gov (United States)

    Mohammed, Anwar; Pecht, Michael

    2016-10-01

    Stretchable electronics can offer an added degree of design freedom and generate products with unprecedented capabilities. Stretchable conductive ink serving as interconnect, is a key enabler for stretchable electronics. This paper focuses on the development of a stretchable and screen printable conductive ink which could be stretched more than 500 cycles at 20% strain while maintaining electrical and mechanical integrity. The screen printable and stretchable conductive ink developed in this paper marks an important milestone for this nascent technology.

  5. RNAi screening for characterisation of ER-associated degradation pathways in mammalian cells

    DEFF Research Database (Denmark)

    Månsson, Mats David Joakim

    in a process termed ER-associated degradation (ERAD). This mechanism proceeds through four steps involving recognition, dislocation, ubiquitination and proteasomal degradation. This report describes a high-throughput screening method for identification of hitherto unknown pathways for degradation. We present...... fluorescence-based RNAi screens in mammalian cells on TCR-α-GFP and HANSκLC, for identification of ERAD pathways. By validating the obtained screening hits we concluded that UBE2J2 is involved in TCR-α-GFP degradation, possibly by ubiquitination of C-terminal serine residues in TCR-α-GFP. Additionally, we also...

  6. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Roman, M., E-mail: Marta.Roman@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Department of Women and Children’s Health, Oslo University Hospital, Oslo (Norway); Skaane, P., E-mail: PERSK@ous-hf.no [Department of Radiology, Oslo University Hospital Ullevaal, University of Oslo, Oslo (Norway); Hofvind, S., E-mail: Solveig.Hofvind@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Faculty of Health Science, Oslo (Norway)

    2014-09-15

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  7. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Roman, M.; Skaane, P.; Hofvind, S.

    2014-01-01

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  8. Tunnelling effect enhanced by lattice screening as main cold fusion mechanism: An brief theoretical overview

    International Nuclear Information System (INIS)

    Frisone, F.

    2007-01-01

    In this paper are illustrated the main features of tunneling traveling between two deuterons within a lattice. Considering the screening effect due lattice electrons we compare the d-d fusion rate evaluated from different authors assuming different screening efficiency and different d-d potentials. Then, we propose a effective potential which describe very well the attractive contribute due to plasmon exchange between two deuterons and by means of it we will compute the d-d fusion rates for different energy values. Finally the good agreement between theoretical and experimental results proves the reality of cold fusion phenomena and the reliability of our model

  9. Alcohol Use Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Alcohol Use Screening (AUDIT-C) - Instructions The following questions ... this tool, there is also text-only version . Alcohol Use Screening (AUDIT-C) - Manual Instructions The following ...

  10. Final screening round of the NELSON lung cancer screening trial: the effect of a 2.5-year screening interval

    NARCIS (Netherlands)

    Yousaf-Khan, U.; Aalst, C. van der; Jong, P.A. de; Heuvelmans, M.; Scholten, E.T.; Lammers, J.-W.J.; Ooijen, P. van; Nackaerts, K.; Weenink, C.; Groen, H.; Vliegenthart, R.; Haaf, K. Ten; Oudkerk, M.; Koning, H. de

    2016-01-01

    In the USA annual lung cancer screening is recommended. However, the optimal screening strategy (eg, screening interval, screening rounds) is unknown. This study provides results of the fourth screening round after a 2.5-year interval in the Dutch-Belgian Lung Cancer Screening trial

  11. Final screening round of the NELSON lung cancer screening trial : the effect of a 2.5-year screening interval

    NARCIS (Netherlands)

    Yousaf-Khan, Uraujh; van der Aalst, Carlijn; de Jong, Pim A; Heuvelmans, Marjolein; Scholten, Ernst; Lammers, Jan-Willem; van Ooijen, Peter; Nackaerts, Kristiaan; Weenink, Carla; Groen, Harry; Vliegenthart, Rozemarijn; Ten Haaf, Kevin; Oudkerk, Matthijs; de Koning, Harry

    BACKGROUND: In the USA annual lung cancer screening is recommended. However, the optimal screening strategy (eg, screening interval, screening rounds) is unknown. This study provides results of the fourth screening round after a 2.5-year interval in the Dutch-Belgian Lung Cancer Screening trial

  12. Final screening round of the NELSON lung cancer screening trial : the effect of a 2.5-year screening interval

    NARCIS (Netherlands)

    Yousaf-Khan, Uraujh; van der Aalst, Carlijn; de Jong, Pim A.; Heuvelmans, Marjolein; Scholten, Ernst; Lammers, Jan-Willem; van Ooijen, Peter; Nackaerts, Kristiaan; Weenink, Carla; Groen, Harry; Vliegenthart, Rozemarijn; Ten Haaf, Kevin; Oudkerk, Matthijs; de Koning, Harry

    Background In the USA annual lung cancer screening is recommended. However, the optimal screening strategy (eg, screening interval, screening rounds) is unknown. This study provides results of the fourth screening round after a 2.5-year interval in the Dutch-Belgian Lung Cancer Screening trial

  13. Simple Screening Methods for Drought and Heat Tolerance in Cowpea

    International Nuclear Information System (INIS)

    Singh, B. B.

    2000-10-01

    Success in breeding for drought tolerance has not been as pronounced as for other traits. This is partly due to lack of simple, cheap and reliable screening methods to select drought tolerant plants/progenies from the segregating populations and partly due to complexity of factors involved in drought tolerance. Measuring drought tolerance through physiological parameters is expensive, time consuming and difficult to use for screening large numbers of lines and segregating populations. Since several factors/mechanisms (in shoot and root) operate independently and/or jointly to enable plants to cope with drought stress, drought tolerance appears as a complex trait. However, if these factors/mechanisms can be separated and studied individually, the components leading to drought tolerance will appear less complex and may be easy to manipulate by breeders. We have developed a simple box screening method for shoot drought tolerance in cowpea, which eliminates the effects of roots and permits non-destructive visual identification of shoot dehydration tolerance. We have also developed a 'root-box pin-board' method to study two dimensional root architecture of individual plants. Using these methods, we have identified two mechanisms of shoot drought tolerance in cowpea which are controlled by single dominant genes and major difference for root architecture among cowpea varieties. Combining deep and dense root system with shoot dehydration tolerance results into highly drought tolerant plants

  14. iScreen: Image-Based High-Content RNAi Screening Analysis Tools.

    Science.gov (United States)

    Zhong, Rui; Dong, Xiaonan; Levine, Beth; Xie, Yang; Xiao, Guanghua

    2015-09-01

    High-throughput RNA interference (RNAi) screening has opened up a path to investigating functional genomics in a genome-wide pattern. However, such studies are often restricted to assays that have a single readout format. Recently, advanced image technologies have been coupled with high-throughput RNAi screening to develop high-content screening, in which one or more cell image(s), instead of a single readout, were generated from each well. This image-based high-content screening technology has led to genome-wide functional annotation in a wider spectrum of biological research studies, as well as in drug and target discovery, so that complex cellular phenotypes can be measured in a multiparametric format. Despite these advances, data analysis and visualization tools are still largely lacking for these types of experiments. Therefore, we developed iScreen (image-Based High-content RNAi Screening Analysis Tool), an R package for the statistical modeling and visualization of image-based high-content RNAi screening. Two case studies were used to demonstrate the capability and efficiency of the iScreen package. iScreen is available for download on CRAN (http://cran.cnr.berkeley.edu/web/packages/iScreen/index.html). The user manual is also available as a supplementary document. © 2014 Society for Laboratory Automation and Screening.

  15. Nonlocal electrostatics in ionic liquids: The key to an understanding of the screening decay length and screened interactions

    Science.gov (United States)

    Kjellander, Roland

    2016-09-01

    Screened electrostatic interactions in ionic liquids are investigated by means of exact statistical mechanical analysis combined with physical arguments that enhance the transparency and conceptual accessibility of the analysis and results. The constituent ions and immersed particles in the liquid can have arbitrary shapes and any internal charge distributions. The decay of the screened electrostatic potential and the free energy of interaction in ionic liquids can be exponentially damped oscillatory (like in molten simple salts) as well as plain exponential and long-ranged (like in dilute electrolyte solutions). Both behaviors are in agreement with the exact statistical mechanical analysis and reasons for their appearances are investigated. Exact but surprisingly simple expressions for the decay parameter κ of the screened electrostatics are obtained, which replace the classical expression for the Debye-Hückel parameter κDH (the reciprocal Debye length). The expressions are applicable both for cases with plain exponential and oscillatory behaviors. The key importance of nonlocal electrostatics is thereby demonstrated explicitly. Dielectric properties of ionic liquids and other electrolytes are investigated, in particular the static dielectric function ɛ ˜ ( k ) and some effective relative permittivities ( Er eff and Er ∗ ), which take roles that the dielectric constant ɛr has for polar liquids consisting of electroneutral molecules. The dielectric constant in the latter case, which is the limit of ɛ ˜ ( k ) when the wave number k → 0, can be expressed solely in terms of dipolar features of the molecules. In contrast to this, the effective dielectric permittivities of ionic liquids have contributions also from quadrupolar, octupolar, and higher multipolar features of the constituent ions. The "dielectric constant" of electrolytes does not exist since ɛ ˜ ( k ) → ∞ when k → 0, a well-known effect of perfect screening. The effective relative

  16. Prostate Cancer Screening in Jamaica: Results of the Largest National Screening Clinic Prostate Cancer Screening in Jamaica: Results of the Largest National Screening Clinic

    International Nuclear Information System (INIS)

    Morrison, B. F.; Aiken, W.; Mayhew, R.; Gordon, Y.; Reid, M.

    2016-01-01

    Prostate cancer is highly prevalent in Jamaica and is the leading cause of cancer-related deaths. Our aim was to evaluate the patterns of screening in the largest organized screening clinic in Jamaica at the Jamaica Cancer Society. A retrospective analysis of all men presenting for screening at the Jamaica Cancer Society from 1995 to 2005 was done. All patients had digital rectal examinations (DRE) and prostate specific antigen (PSA) tests done. Results of prostate biopsies were noted. 1117 men of mean age 59.9 ± 8.2 years presented for screening. The median documented PSA was 1.6 ng/mL (maximum of 5170 ng/mL). Most patients presented for only 1 screen. There was a gradual reduction in the mean age of presentation for screening over the period. Prostate biopsies were requested on 11% of screening visits; however, only 59% of these were done. 5.6% of all persons screened were found to have cancer. Of the cancers diagnosed, Gleason 6 adenocarcinoma was the commonest grade and median PSA was 8.9 ng/mL (range 1.5-1059 ng/mL). Older men tend to screen for prostate cancer in Jamaica. However, compliance with regular maintenance visits and requests for confirmatory biopsies are poor. Screening needs intervention in the Jamaican population.

  17. Sedation, sleep promotion, and delirium screening practices in the care of mechanically ventilated children: a wake-up call for the pediatric critical care community*.

    Science.gov (United States)

    Kudchadkar, Sapna R; Yaster, Myron; Punjabi, Naresh M

    2014-07-01

    To examine pediatric intensivist sedation management, sleep promotion, and delirium screening practices for intubated and mechanically ventilated children. An international, online survey of questions regarding sedative and analgesic medication choices and availability, sedation protocols, sleep optimization, and delirium recognition and treatment. Member societies of the World Federation of Pediatric Intensive and Critical Care Societies were asked to send the survey to their mailing lists; responses were collected from July 2012 to January 2013. Pediatric critical care providers. Survey. The survey was completed by 341 respondents, the majority of whom were from North America (70%). Twenty-seven percent of respondents reported having written sedation protocols. Most respondents worked in PICUs with sedation scoring systems (70%), although only 42% of those with access to scoring systems reported routine daily use for goal-directed sedation management. The State Behavioral Scale was the most commonly used scoring system in North America (22%), with the COMFORT score more prevalent in all other countries (39%). The most commonly used sedation regimen for intubated children was a combination of opioid and benzodiazepine (72%). Most intensivists chose fentanyl as their first-line opioid (66%) and midazolam as their first-line benzodiazepine (86%) and prefer to administer these medications as continuous infusions. Propofol and dexmedetomidine were the most commonly restricted medications in PICUs internationally. Use of earplugs, eye masks, noise reduction, and lighting optimization for sleep promotion was uncommon. Delirium screening was not practiced in 71% of respondent's PICUs, and only 2% reported routine screening at least twice a day. The results highlight the heterogeneity in sedation practices among intensivists who care for critically ill children as well as a paucity of sleep promotion and delirium screening in PICUs worldwide.

  18. Astrophysical tests of gravity: a screening map of the nearby universe

    Energy Technology Data Exchange (ETDEWEB)

    Cabré, Anna; Vikram, Vinu; Jain, Bhuvnesh [Center for Particle Cosmology, Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104-6396 (United States); Zhao, Gong-Bo; Koyama, Kazuya, E-mail: annanusca@gmail.com, E-mail: vinu@sas.upenn.edu, E-mail: gong-bo.zhao@port.ac.uk, E-mail: bjain@physics.upenn.edu, E-mail: Kazuya.Koyama@port.ac.uk [Institute of Cosmology and Gravitation, University of Portsmouth, Dennis Sciama Building, Burnaby Road, Portsmouth, PO1 3FX (United Kingdom)

    2012-07-01

    Astrophysical tests of modified gravity theories in the nearby universe have been emphasized recently by Hui 2009 and Jain 2011. A key element of such tests is the screening mechanism whereby general relativity is restored in massive halos or high density environments like the Milky Way. In chameleon theories of gravity, including all f(R) models, field dwarf galaxies may be unscreened and therefore feel an extra force, as opposed to screened galaxies. The first step to study differences between screened and unscreened galaxies is to create a 3D screening map. We use N-body simulations to test and calibrate simple approximations to determine the level of screening in galaxy catalogs. Sources of systematic errors in the screening map due to observational inaccuracies are modeled and their contamination is estimated. We then apply our methods to create a map out to 200 Mpc in the Sloan Digital Sky Survey footprint using data from the Sloan survey and other sources. In two companion papers this map will be used to carry out new tests of gravity using distance indicators and the disks of dwarf galaxies. We also make our screening map publicly available.

  19. Automated Groundwater Screening

    International Nuclear Information System (INIS)

    Taylor, Glenn A.; Collard, Leonard B.

    2005-01-01

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application

  20. The screening of charged impurities in bilayer graphene

    International Nuclear Information System (INIS)

    Zhang Wenjing; Li, Lain-Jong

    2010-01-01

    Positively charged impurities were introduced into a bilayer graphene (BLG) transistor by n-doping with dimethylformamide. Subsequent exposure of the BLG device to moisture resulted in a positive shift of the Dirac point and an increase of hole mobility, suggesting that moisture could reduce the scattering strength of the existing charged impurities. In other words, moisture screened off the 'effective density' of charged impurities. At the early stage of moisture screening the scattering of hole carriers is dominated by long-range Coulomb scatter, but an alternative scattering mechanism should also be taken into consideration when the effective density of impurities is further lowered on moisture exposure.

  1. Breast cancer screening

    Science.gov (United States)

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... is performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  2. The use of twin-screen-based WIMPS in spacecraft control

    Science.gov (United States)

    Klim, R. D.

    1990-10-01

    The ergonomic problems of designing a sophisticated Windows Icons Mouse Pop-up (WIMP) based twin screen workstation are outlined. These same problems will be encountered by future spacecraft controllers. The design of a modern, advanced workstation for use on a distributed multicontrol center in a multisatellite control system is outlined. The system uses access control mechanisms to ensure that only authorized personnel can undertake certain operations on the workstation. Rules governing the use of windowing features, screen attributes, icons, keyboard and mouse in spacecraft control are discussed.

  3. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  4. Hyperkaehlerian manifolds and exact β functions of two-dimensional N=4 supersymmetric σ models

    International Nuclear Information System (INIS)

    Morozov, A.Yu.; Perelomov, A.M.

    1984-01-01

    Two-dimensional supersymmetric sigma-models on cotangent bundles over CPsup(n) are investigated. These mannfolds are supplied with hyperkaehlerian metrics, and the corresponding σ-models possess N=4 supersymmetry. Also they admit instantonic solutions, which permits to apply the Novikov-Shifman-Vainshtein-Zakharov method and calculate exact β-functions. βsup(gsup(2)) = 0, as was expected

  5. [Methodology of Screening New Antibiotics: Present Status and Prospects].

    Science.gov (United States)

    Trenin, A S

    2015-01-01

    Due to extensive distribution of pathogen resistance to available pharmaceuticals and serious problems in the treatment of various infections and tumor diseases, the necessity of new antibiotics is urgent. The basic methodological approaches to chemical synthesis of antibiotics and screening of new antibiotics among natural products, mainly among microbial secondary metabolites, are considered in the review. Since the natural compounds are very much diverse, screening of such substances gives a good opportunity to discover antibiotics of various chemical structure and mechanism of action. Such an approach followed by chemical or biological transformation, is capable of providing the health care with new effective pharmaceuticals. The review is mainly concentrated on screening of natural products and methodological problems, such as: isolation of microbial producers from the habitats, cultivation of microorganisms producing appropriate substances, isolation and chemical characterization of microbial metabolites, identification of the biological activity of the metabolites. The main attention is paid to the problems of microbial secondary metabolism and design of new models for screening biologically active compounds. The last achievements in the field of antibiotics and most perspective approaches to future investigations are discussed. The main methodological approach to isolation and cultivation of the producers remains actual and needs constant improvement. The increase of the screening efficiency can be achieved by more rapid chemical identification of antibiotics and design of new screening models based on the biological activity detection.

  6. Scintillating screens study for LEIR/LHC heavy ion beams

    CERN Document Server

    Bal, C; Lefèvre, T; Scrivens, R; Taborelli, M

    2005-01-01

    It has been observed on different machines that scintillating ceramic screens (like chromium doped alumina) are quickly damaged by low energy ion beams. These particles are completely stopped on the surface of the screens, inducing both a high local temperature increase and the electrical charging of the material. A study has been initiated to understand the limiting factors and the damage mechanisms. Several materials, ZrO2, BN and Al2O3, have been tested at CERN on LINAC3 with 4.2MeV/u lead ions. Alumina (Al2O3) is used as the reference material as it is extensively used in beam imaging systems. Boron nitride (BN) has better thermal properties than Alumina and Zirconium oxide (ZrO2). BN has in fact the advantage of increasing its electrical conductivity when heated. This contribution presents the results of the beam tests, including the post-mortem analysis of the screens and the outlook for further measurements. The strategy for the choice of the screens for the Low Energy Ion Ring (LEIR), currently under ...

  7. APS Beyond Positivity Bounds and the Fate of Massive Gravity

    CERN Document Server

    Bellazzini, Brando; Serra, Javi; Sgarlata, Francesco

    2018-04-18

    We constrain effective field theories by going beyond the familiar positivity bounds that follow from unitarity, analyticity, and crossing symmetry of the scattering amplitudes. As interesting examples, we discuss the implications of the bounds for the Galileon and ghost-free massive gravity. The combination of our theoretical bounds with the experimental constraints on the graviton mass implies that the latter is either ruled out or unable to describe gravitational phenomena, let alone to consistently implement the Vainshtein mechanism, down to the relevant scales of fifth-force experiments, where general relativity has been successfully tested. We also show that the Galileon theory must contain symmetry-breaking terms that are at most one-loop suppressed compared to the symmetry-preserving ones. We comment as well on other interesting applications of our bounds.

  8. Spherical cows in the sky with fab four

    Energy Technology Data Exchange (ETDEWEB)

    Kaloper, Nemanja; Sandora, McCullen, E-mail: kaloper@physics.ucdavis.edu, E-mail: mesandora@ucdavis.edu [Department of Physics, University of California, Davis, CA 95616 (United States)

    2014-05-01

    We explore spherically symmetric static solutions in a subclass of unitary scalar-tensor theories of gravity, called the 'Fab Four' models. The weak field large distance solutions may be phenomenologically viable, but only if the Gauss-Bonnet term is negligible. Only in this limit will the Vainshtein mechanism work consistently. Further, classical constraints and unitarity bounds constrain the models quite tightly. Nevertheless, in the limits where the range of individual terms at large scales is respectively Kinetic Braiding, Horndeski, and Gauss-Bonnet, the horizon scale effects may occur while the theory satisfies Solar system constraints and, marginally, unitarity bounds. On the other hand, to bring the cutoff down to below a millimeter constrains all the couplings scales such that 'Fab Fours' can't be heard outside of the Solar system.

  9. Screening for pain-persistence and pain-avoidance patterns in fibromyalgia.

    NARCIS (Netherlands)

    Koulil, S. van; Kraaimaat, F.W.; Lankveld, W.G.J.M. van; Helmond, T. van; Vedder, A.; Hoorn, H. van; Cats, H.; Riel, P.L.C.M. van; Evers, A.W.M.

    2008-01-01

    BACKGROUND: The heterogeneity of patients regarding pain-related cognitive-behavioral mechanisms, such as pain-avoidance and pain-persistence patterns, has been proposed to underlie varying treatment outcomes in patients with fibromyalgia (FM). PURPOSE: To investigate the validity of a screening

  10. Prenatal screening and genetics

    DEFF Research Database (Denmark)

    Alderson, P; Aro, A R; Dragonas, T

    2001-01-01

    Although the term 'genetic screening' has been used for decades, this paper discusses how, in its most precise meaning, genetic screening has not yet been widely introduced. 'Prenatal screening' is often confused with 'genetic screening'. As we show, these terms have different meanings, and we...... examine definitions of the relevant concepts in order to illustrate this point. The concepts are i) prenatal, ii) genetic screening, iii) screening, scanning and testing, iv) maternal and foetal tests, v) test techniques and vi) genetic conditions. So far, prenatal screening has little connection...... with precisely defined genetics. There are benefits but also disadvantages in overstating current links between them in the term genetic screening. Policy making and professional and public understandings about screening could be clarified if the distinct meanings of prenatal screening and genetic screening were...

  11. Virtual screening of cocrystal formers for CL-20

    Science.gov (United States)

    Zhou, Jun-Hong; Chen, Min-Bo; Chen, Wei-Ming; Shi, Liang-Wei; Zhang, Chao-Yang; Li, Hong-Zhen

    2014-08-01

    According to the structure characteristics of 2,4,6,8,10,12-hexanitrohexaazaisowurtzitane (CL-20) and the kinetic mechanism of the cocrystal formation, the method of virtual screening CL-20 cocrystal formers by the criterion of the strongest intermolecular site pairing energy (ISPE) was proposed. In this method the strongest ISPE was thought to determine the first step of the cocrystal formation. The prediction results for four sets of common drug molecule cocrystals by this method were compared with those by the total ISPE method from the reference (Musumeci et al., 2011), and the experimental results. This method was then applied to virtually screen the CL-20 cocrystal formers, and the prediction results were compared with the experimental results.

  12. Study on screening of anti-predator rhizosphere bacterium against Caenorhabditis elegans and its anti predation mechanism

    Directory of Open Access Journals (Sweden)

    HE Qingling

    2016-08-01

    Full Text Available Althoughmicrobial fertilizer is multi-effect,environmental friendly and long-term efficient,its practical application effect is but decreased for being prey by the other creators living in soil frequently.Many bacterium have developed their mechanisms that expel or kill worms to defend themselves from predators.Screening of anti-predator rhizosphere bacterium helps us to find out competitive plant growth promoting rhizobacteria(PGPR.Using Caenorhabditis elegans as sample,this study roughly observed two strains of biocontrol:Pseudomonas aurantiaca JD37 and Pseudomonas fluorescens P13.Using Escherichia coli OP50 as control group,we find the preference order of worms,from highest to lowest,is P13,OP50 and JD37.In slow killing assay,the death rate of worms for JD37 and P13 are 26.12% and 18.66% respectively.The activity and reproduction rate of C.elegans decrease when it is fed on JD37.The results of chemical and micro-biological study show that JD37 cannot produce any currently studied second metabolites which kill worms,while P13 can produce Hydrogen cyanide (HCN.All these results show that JD37 has the ability of anti-predator,and is more competitive under predation pressure,which suggests its broad application prospect as microbial fertilizer.

  13. Lunar Dust Mitigation Screens

    Science.gov (United States)

    Knutson, Shawn; Holloway, Nancy

    With plans for the United States to return to the moon, and establish a sustainable human presence on the lunar surface many issues must be successfully overcome. Lunar dust is one of a number of issues with the potential to create a myriad of problems if not adequately addressed. Samples of dust brought back from Apollo missions show it to be soft, yet sharp and abrasive. The dust consists of a variety of morphologies including spherical, angular blocks, shards, and a number of irregular shapes. One of the main issues with lunar dust is its attraction to stick to anything it comes in contact with (i.e. astronauts, equipment, habitats, etc.). Ionized radiation from the sun strikes the moon's surface and creates an electrostatic charge on the dust. Further, the dust harbors van der Waals forces making it especially difficult to separate once it sticks to a surface. During the Apollo missions, it was discovered that trying to brush the lunar dust from spacesuits was not effective, and rubbing it caused degradation of the suit material. Further, when entering the lunar module after moonwalks, the astronauts noted that the dust was so prolific inside the cabin that they inhaled and ingested it, causing at least one of them, Harrison "Jack" Schmidt, to report irritation of the throat and lungs. It is speculated that the dust could also harm an astronaut's nervous and cardiovascular systems, especially during an extended stay. In addition to health issues, the dust can also cause problems by scouring reflective coatings off of thermal blankets, and roughening surfaces of windows and optics. Further, panels on solar cells and photovoltaics can also be compromised due to dust sticking on the surfaces. Lunar dust has the capacity to penetrate seals, interfere with connectors, as well as mechanisms on digging machines, all of which can lead to problems and failure. To address lunar dust issues, development of electrostatic screens to mitigate dust on sur-faces is currently

  14. 3D mosquito screens to create window double screen traps for mosquito control.

    Science.gov (United States)

    Khattab, Ayman; Jylhä, Kaisa; Hakala, Tomi; Aalto, Mikko; Malima, Robert; Kisinza, William; Honkala, Markku; Nousiainen, Pertti; Meri, Seppo

    2017-08-29

    Mosquitoes are vectors for many diseases such as malaria. Insecticide-treated bed nets and indoor residual spraying of insecticides are the principal malaria vector control tools used to prevent malaria in the tropics. Other interventions aim at reducing man-vector contact. For example, house screening provides additive or synergistic effects to other implemented measures. We used commercial screen materials made of polyester, polyethylene or polypropylene to design novel mosquito screens that provide remarkable additional benefits to those commonly used in house screening. The novel design is based on a double screen setup made of a screen with 3D geometric structures parallel to a commercial mosquito screen creating a trap between the two screens. Owing to the design of the 3D screen, mosquitoes can penetrate the 3D screen from one side but cannot return through the other side, making it a unidirectional mosquito screen. Therefore, the mosquitoes are trapped inside the double screen system. The permissiveness of both sides of the 3D screens for mosquitoes to pass through was tested in a wind tunnel using the insectary strain of Anopheles stephensi. Among twenty-five tested 3D screen designs, three designs from the cone, prism, or cylinder design groups were the most efficient in acting as unidirectional mosquito screens. The three cone-, prism-, and cylinder-based screens allowed, on average, 92, 75 and 64% of Anopheles stephensi mosquitoes released into the wind tunnel to penetrate the permissive side and 0, 0 and 6% of mosquitoes to escape through the non-permissive side, respectively. A cone-based 3D screen fulfilled the study objective. It allowed capturing 92% of mosquitoes within the double screen setup inside the wind tunnel and blocked 100% from escaping. Thus, the cone-based screen effectively acted as a unidirectional mosquito screen. This 3D screen-based trap design could therefore be used in house screening as a means of avoiding infective bites and

  15. Variations in screening outcome among pairs of screening radiologists at non-blinded double reading of screening mammograms: a population-based study

    NARCIS (Netherlands)

    Klompenhouwer, E. G.; Duijm, L. E. M.; Voogd, A. C.; den Heeten, G. J.; Nederend, J.; Jansen, F. H.; Broeders, M. J. M.

    2014-01-01

    Substantial inter-observer variability in screening mammography interpretation has been reported at single reading. However, screening results of pairs of screening radiologists have not yet been published. We determined variations in screening performances among pairs of screening radiologists at

  16. Environmental screening of dark matter haloes in f(R) gravity

    Science.gov (United States)

    Shi, Difu; Li, Baojiu; Han, Jiaxin

    2017-07-01

    In certain theories of modified gravity, Solar system constraints on deviations from general relativity (GR) are satisfied by virtue of a so-called screening mechanism, which enables the theory to revert to GR in regions where the matter density is high or the gravitational potential is deep. In the case of chameleon theories, the screening has two contributions - self-screening, which is due to the mass of an object itself, and environmental screening, which is caused by the surrounding matter - which are often entangled, with the second contribution being more crucial for less massive objects. A quantitative understanding of the effect of the environment on the screening can prove critical in observational tests of such theories using systems such as the Local Group and dwarf galaxies, for which the environment may be inferred in various ways. We use the high-resolution liminality simulation of Shi et al. to test the fidelity of different definitions of environment. We find that, although the different ways to define environment in practice do not agree with one another perfectly, they can provide useful guidance, and cross checks about how well a dark matter halo is screened. In addition, the screening of subhaloes in dark matter haloes is primarily determined by the environment, with the subhalo mass playing a minor role, which means that lower resolution simulations where subhaloes are not well resolved can still be useful for understanding the modification of gravity inside subhaloes.

  17. Cancer screening guidelines.

    Science.gov (United States)

    Zoorob, R; Anderson, R; Cefalu, C; Sidani, M

    2001-03-15

    Numerous medical organizations have developed cancer screening guidelines. Faced with the broad, and sometimes conflicting, range of recommendations for cancer screening, family physicians must determine the most reasonable and up-to-date method of screening. Major medical organizations have generally achieved consensus on screening guidelines for breast, cervical and colorectal cancer. For breast cancer screening in women ages 50 to 70, clinical breast examination and mammography are generally recommended every one or two years, depending on the medical organization. For cervical cancer screening, most organizations recommend a Papanicolaou test and pelvic examination at least every three years in patients between 20 and 65 years of age. Annual fecal occult blood testing along with flexible sigmoidoscopy at five-year to 10-year intervals is the standard recommendation for colorectal cancer screening in patients older than 50 years. Screening for prostate cancer remains a matter of debate. Some organizations recommend digital rectal examination and a serum prostate-specific antigen test for men older than 50 years, while others do not. In the absence of compelling evidence to indicate a high risk of endometrial cancer, lung cancer, oral cancer and ovarian cancer, almost no medical organizations have developed cancer screening guidelines for these types of cancer.

  18. Screen Media Exposure and Obesity in Children and Adolescents.

    Science.gov (United States)

    Robinson, Thomas N; Banda, Jorge A; Hale, Lauren; Lu, Amy Shirong; Fleming-Milici, Frances; Calvert, Sandra L; Wartella, Ellen

    2017-11-01

    Obesity is one of the best-documented outcomes of screen media exposure. Many observational studies find relationships between screen media exposure and increased risks of obesity. Randomized controlled trials of reducing screen time in community settings have reduced weight gain in children, demonstrating a cause and effect relationship. Current evidence suggests that screen media exposure leads to obesity in children and adolescents through increased eating while viewing; exposure to high-calorie, low-nutrient food and beverage marketing that influences children's preferences, purchase requests, consumption habits; and reduced sleep duration. Some evidence also suggests promise for using interactive media to improve eating and physical activity behaviors to prevent or reduce obesity. Future interdisciplinary research is needed to examine the effects of newer mobile and other digital media exposures on obesity; to examine the effectiveness of additional interventions to mitigate the adverse effects of media exposures on obesity and possible moderators and mediators of intervention effects; to effectively use digital media interventions to prevent and reduce obesity; and to uncover the mechanisms underlying the causal relationships and interactions between obesity-related outcomes and media content, characteristics, and context. Copyright © 2017 by the American Academy of Pediatrics.

  19. Screen Media Exposure and Obesity in Children and Adolescents

    Science.gov (United States)

    Robinson, Thomas N.; Banda, Jorge A.; Hale, Lauren; Lu, Amy Shirong; Fleming-Milici, Frances; Calvert, Sandra L.; Wartella, Ellen

    2018-01-01

    Obesity is one of the best-documented outcomes of screen media exposure. Many observational studies find relationships between screen media exposure and increased risks of obesity. Randomized controlled trials of reducing screen time in community settings have reduced weight gain in children, demonstrating a cause and effect relationship. Current evidence suggests that screen media exposure leads to obesity in children and adolescents through increased eating while viewing; exposure to high-calorie, low-nutrient food and beverage marketing that influences children’s preferences, purchase requests, consumption habits; and reduced sleep duration. Some evidence also suggests promise for using interactive media to improve eating and physical activity behaviors to prevent or reduce obesity. Future interdisciplinary research is needed to examine the effects of newer mobile and other digital media exposures on obesity; to examine the effectiveness of additional interventions to mitigate the adverse effects of media exposures on obesity and possible moderators and mediators of intervention effects; to effectively use digital media interventions to prevent and reduce obesity; and to uncover the mechanisms underlying the causal relationships and interactions between obesity-related outcomes and media content, characteristics, and context. PMID:29093041

  20. Applying operations research to optimize a novel population management system for cancer screening.

    Science.gov (United States)

    Zai, Adrian H; Kim, Seokjin; Kamis, Arnold; Hung, Ken; Ronquillo, Jeremiah G; Chueh, Henry C; Atlas, Steven J

    2014-02-01

    To optimize a new visit-independent, population-based cancer screening system (TopCare) by using operations research techniques to simulate changes in patient outreach staffing levels (delegates, navigators), modifications to user workflow within the information technology (IT) system, and changes in cancer screening recommendations. TopCare was modeled as a multiserver, multiphase queueing system. Simulation experiments implemented the queueing network model following a next-event time-advance mechanism, in which systematic adjustments were made to staffing levels, IT workflow settings, and cancer screening frequency in order to assess their impact on overdue screenings per patient. TopCare reduced the average number of overdue screenings per patient from 1.17 at inception to 0.86 during simulation to 0.23 at steady state. Increases in the workforce improved the effectiveness of TopCare. In particular, increasing the delegate or navigator staff level by one person improved screening completion rates by 1.3% or 12.2%, respectively. In contrast, changes in the amount of time a patient entry stays on delegate and navigator lists had little impact on overdue screenings. Finally, lengthening the screening interval increased efficiency within TopCare by decreasing overdue screenings at the patient level, resulting in a smaller number of overdue patients needing delegates for screening and a higher fraction of screenings completed by delegates. Simulating the impact of changes in staffing, system parameters, and clinical inputs on the effectiveness and efficiency of care can inform the allocation of limited resources in population management.

  1. Screening for colorectal cancer.

    Science.gov (United States)

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  2. Skin Cancer Screening

    Science.gov (United States)

    ... Genetics of Skin Cancer Skin Cancer Screening Research Skin Cancer Screening (PDQ®)–Patient Version What is screening? ... These are called diagnostic tests . General Information About Skin Cancer Key Points Skin cancer is a disease ...

  3. Screening for Cancer

    Science.gov (United States)

    Cancer screening is checking for cancer in people who don't have symptoms. Screening tests can help doctors find and treat several types of cancer early, but cancer screening can have harms as well as benefits.

  4. Introduction to the AJA research forum on aging and hearing: mechanisms and effects.

    Science.gov (United States)

    Paglialonga, Alessia; Grandori, Ferdinando

    2013-12-01

    PURPOSE This Research Forum, "Aging and Hearing: Mechanisms and Effects," highlights 6 contributions presented at the 2nd International Conference on Adult Hearing Screening (AHS 2012), held in Cernobbio (Lake Como, Italy) in June 2012. Overall, the articles in this Research Forum give insight into the causes, mechanisms, and consequences of auditory dysfunctions in adults, with particular focus on their implications for screening, assessment, and intervention.

  5. Domestic violence screening in a military setting: provider screening and attitudes.

    Science.gov (United States)

    Lutgendorf, Monica; Busch, Jeanne; Magann, Everett F; Morrison, John C

    2010-06-01

    Domestic violence is an important healthcare problem, and it appears more prevalent in military patient populations although no one has demonstrated the cause behind this phenomenon. The purpose of this observational study was to assess data regarding domestic violence screening from practitioners at one military training center. This study used an anonymous questionnaire for physicians, nurses and nurse midwives, which surveyed current methods, attitudes toward screening, and barriers for such assessment. Fifty-seven surveys were distributed, and 26 were returned for a response rate of 45.6%. Only about a third (38.5%) of the practitioners screened all obstetric patients while the remainder screened selected patients for domestic violence. Even less (19%) screened gynecology patients routinely, whereas 69% reported they screened selected women with chronic or somatic complaints. A history of prior abuse in the respondents led practitioners to try to identify such patients within their practice. Lack of education or training was the most common barrier to universal screening followed by time constraints and frustration about not being able to address adequately the problem when noted. These results emphasized the importance of an educational program to increase domestic violence awareness and routine screening.

  6. A perturbative approach to the redshift space correlation function: beyond the Standard Model

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Benjamin; Koyama, Kazuya, E-mail: benjamin.bose@port.ac.uk, E-mail: kazuya.koyama@port.ac.uk [Institute of Cosmology and Gravitation, University of Portsmouth, Burnaby Road, Portsmouth, Hampshire, PO1 3FX (United Kingdom)

    2017-08-01

    We extend our previous redshift space power spectrum code to the redshift space correlation function. Here we focus on the Gaussian Streaming Model (GSM). Again, the code accommodates a wide range of modified gravity and dark energy models. For the non-linear real space correlation function used in the GSM we use the Fourier transform of the RegPT 1-loop matter power spectrum. We compare predictions of the GSM for a Vainshtein screened and Chameleon screened model as well as GR. These predictions are compared to the Fourier transform of the Taruya, Nishimichi and Saito (TNS) redshift space power spectrum model which is fit to N-body data. We find very good agreement between the Fourier transform of the TNS model and the GSM predictions, with ≤ 6% deviations in the first two correlation function multipoles for all models for redshift space separations in 50Mpc h ≤ s ≤ 180Mpc/ h . Excellent agreement is found in the differences between the modified gravity and GR multipole predictions for both approaches to the redshift space correlation function, highlighting their matched ability in picking up deviations from GR. We elucidate the timeliness of such non-standard templates at the dawn of stage-IV surveys and discuss necessary preparations and extensions needed for upcoming high quality data.

  7. Radiation accident dosimetry: TL properties of mobile phone screen glass

    International Nuclear Information System (INIS)

    Bassinet, C.; Pirault, N.; Baumann, M.; Clairand, I.

    2014-01-01

    Mobile phones are carried by a large part of the population and previous studies have shown that they may be able to function as individual fortuitous dosimeters in case of radiological accident. This study deals with thermoluminescence (TL) properties of mobile phone screen glass. The presence of a significant background signal which partially overlaps with the radiation-induced signal is a serious issue for dose reconstruction. A mechanical method to reduce this signal using a diamond grinding bit is presented. An over-response at low energy (∼50 keV) is observed for two investigated glasses. The results of a dose recovery test using a single-aliquot regenerative-dose (SAR) procedure are discussed. - Highlights: • Mobile phone screen glass is a promising material for retrospective dosimetry. • The TL non-radiation induced background signal can be significantly reduced by a mechanical method. • A dose recovery test using an SAR procedure was successfully carried out for the investigated glass

  8. On uncertainty relations in quantum mechanics

    International Nuclear Information System (INIS)

    Ignatovich, V.K.

    2004-01-01

    Uncertainty relations (UR) are shown to have nothing specific for quantum mechanics (QM), being the general property valid for the arbitrary function. A wave function of a particle simultaneously having a precisely defined position and momentum in QM is demonstrated. Interference on two slits in a screen is shown to exist in classical mechanics. A nonlinear classical system of equations replacing the QM Schroedinger equation is suggested. This approach is shown to have nothing in common with the Bohm mechanics

  9. Colorectal Cancer Screening

    Science.gov (United States)

    ... Genetics of Colorectal Cancer Colorectal Cancer Screening Research Colorectal Cancer Screening (PDQ®)–Patient Version What is screening? Go ... These are called diagnostic tests . General Information About Colorectal Cancer Key Points Colorectal cancer is a disease in ...

  10. Physico-mechanical and chemical screening of packaging plastics and laminates for food irradiation

    International Nuclear Information System (INIS)

    Cabalar, Patrick Jay E.; Laurio, Christian D.

    2014-03-01

    Evaluation of selected commercially-available packaging plastics and laminated plastics i.e., PET12/PE50, PET12/CPS40, Laminaed PET/PE, VMPET12/PE70, Nylon/PE, Nylon15/PE50, PET/Foil/PE, PlainPET/FOIL7/PE100, and OPP20/Foil6.5/PE40, are conducted by employing methods for determining physico-mechanical properties and performing chemical analyses to assess the suitability for food irradiation at 10kGy. Isotope Ratio Mass Spectrometry (IR-MS0 is also performed to measure isotopic ratio changes of 18 O/ 16 O and 2 H/ 1 H to determine raqdiolysis on water in contact with the packaging materials. IR-MS suggests that PET/FOIL PE and OPP 20/Foil 6.5/PE40 in δ 18 O%o after irradiation has significantly increased. Tensile strength and Young's modulus are obtained to assess physical changes between irradiated samples. Data showed that PET12/CPS40 have the highet tensile strength 60.2 MPa and Young's modulus (141.80GPa) value, after irradiation and has no significant difference to their non irradiated samples. Other packaging materials with the same result are OPP20/FOIL6.5/PE40, PET12/PE50 and NYLON50/PE. Residual test gives information on the extent of leaching or radiolytic byproduct evolved upon irradiation. Based on the result, all packaging plastics and laminates passess the overall migration test since residues did not significanty migrated. Chemical screening includes GPC and GC-MS analyses in determining the possible radiolytic by-products that liberate upon rdiation of the samples s well as determining the components that is already present prior to irradiation. Based on the comparison of the chromatograms ofGPC for both samples of VMPET12/PE70 and OPP20/Foil6.5/PE40, radiation has small effect on the yield of radiolytic leachates aside from increasing the abundance of the componenet that is already present prior to irradiation. GC-MS results suggest that PET/FOIL/PE produced volatile compounds before and after irradiation namely 3,3-Dimethylheptane (8

  11. Screening_mgmt: a Python module for managing screening data.

    Science.gov (United States)

    Helfenstein, Andreas; Tammela, Päivi

    2015-02-01

    High-throughput screening is an established technique in drug discovery and, as such, has also found its way into academia. High-throughput screening generates a considerable amount of data, which is why specific software is used for its analysis and management. The commercially available software packages are often beyond the financial limits of small-scale academic laboratories and, furthermore, lack the flexibility to fulfill certain user-specific requirements. We have developed a Python module, screening_mgmt, which is a lightweight tool for flexible data retrieval, analysis, and storage for different screening assays in one central database. The module reads custom-made analysis scripts and plotting instructions, and it offers a graphical user interface to import, modify, and display the data in a uniform manner. During the test phase, we used this module for the management of 10,000 data points of various origins. It has provided a practical, user-friendly tool for sharing and exchanging information between researchers. © 2014 Society for Laboratory Automation and Screening.

  12. Cardiac Arrhythmia: In vivo screening in the zebrafish to overcome complexity in drug discovery.

    Science.gov (United States)

    Macrae, Calum A

    2010-07-01

    IMPORTANCE OF THE FIELD: Cardiac arrhythmias remain a major challenge for modern drug discovery. Clinical events are paroxysmal, often rare and may be asymptomatic until a highly morbid complication. Target selection is often based on limited information and though highly specific agents are identified in screening, the final efficacy is often compromised by unanticipated systemic responses, a narrow therapeutic index and substantial toxicities. AREAS COVERED IN THIS REVIEW: Our understanding of complexity of arrhythmogenesis has grown dramatically over the last two decades, and the range of potential disease mechanisms now includes pathways previously thought only tangentially involved in arrhythmia. This review surveys the literature on arrhythmia mechanisms from 1965 to the present day, outlines the complex biology underlying potentially each and every rhythm disturbance, and highlights the problems for rational target identification. The rationale for in vivo screening is described and the utility of the zebrafish for this approach and for complementary work in functional genomics is discussed. Current limitations of the model in this setting and the need for careful validation in new disease areas are also described. WHAT THE READER WILL GAIN: An overview of the complex mechanisms underlying most clinical arrhythmias, and insight into the limits of ion channel conductances as drug targets. An introduction to the zebrafish as a model organism, in particular for cardiovascular biology. Potential approaches to overcoming the hurdles to drug discovery in the face of complex biology including in vivo screening of zebrafish genetic disease models. TAKE HOME MESSAGE: In vivo screening in faithful disease models allows the effects of drugs on integrative physiology and disease biology to be captured during the screening process, in a manner agnostic to potential drug target or targets. This systematic strategy bypasses current gaps in our understanding of disease

  13. Reading touch screen storybooks with mothers negatively affects seven-year-old readers’ comprehension but enriches emotional engagement

    Directory of Open Access Journals (Sweden)

    Kirsty Mhairi Ross

    2016-11-01

    Full Text Available Touch screen storybooks turn reading into an interactive multimedia experience, with hotspot-activated animations, sound effects, and games. Positive and negative effects of reading multimedia stories have been reported, but the underlying mechanisms which explain how children’s learning is affected remain uncertain. The present study examined the effect of storybook format (touch screen and print on story comprehension, and considered how level of touch screen interactivity (high and low and shared reading behaviors (cognitive and emotional scaffolding, emotional engagement might contribute to comprehension. Seven-year-olds (n = 22 were observed reading one touch screen storybook and one print storybook with their mothers. Story comprehension was inferior for the touch screen storybooks compared to the print versions. Touch screen interactivity had no significant effect on comprehension but did affect shared reading behaviors. The mother-child dyads spent less time talking about the story in the highly interactive touch screen condition, despite longer shared reading sessions because of touch screen interactions. Positive emotional engagement was greater for children and mothers in the highly interactive touch screen condition, due to additional positive emotions expressed during touch screen interactions. Negative emotional engagement was greater for children when reading and talking about the story in the highly interactive condition, and some mothers demonstrated negative emotional engagement with the touch screen activities. The less interactive touch screen storybook had little effect on shared reading behaviors, but mothers controlling behaviors were more frequent. Storybook format had no effect on the frequency of mothers’ cognitive scaffolding behaviors (comprehension questions, word help. Relationships between comprehension and shared reading behaviors were examined for each storybook, and length of the shared reading session and

  14. Reading Touch Screen Storybooks with Mothers Negatively Affects 7-Year-Old Readers’ Comprehension but Enriches Emotional Engagement

    Science.gov (United States)

    Ross, Kirsty M.; Pye, Rachel E.; Randell, Jordan

    2016-01-01

    Touch screen storybooks turn reading into an interactive multimedia experience, with hotspot-activated animations, sound effects, and games. Positive and negative effects of reading multimedia stories have been reported, but the underlying mechanisms which explain how children’s learning is affected remain uncertain. The present study examined the effect of storybook format (touch screen and print) on story comprehension, and considered how level of touch screen interactivity (high and low) and shared reading behaviors (cognitive and emotional scaffolding, emotional engagement) might contribute to comprehension. Seven-year-olds (n = 22) were observed reading one touch screen storybook and one print storybook with their mothers. Story comprehension was inferior for the touch screen storybooks compared to the print formats. Touch screen interactivity level had no significant effect on comprehension but did affect shared reading behaviors. The mother–child dyads spent less time talking about the story in the highly interactive touch screen condition, despite longer shared reading sessions because of touch screen interactions. Positive emotional engagement was greater for children and mothers in the highly interactive touch screen condition, due to additional positive emotions expressed during touch screen interactions. Negative emotional engagement was greater for children when reading and talking about the story in the highly interactive condition, and some mothers demonstrated negative emotional engagement with the touch screen activities. The less interactive touch screen storybook had little effect on shared reading behaviors, but mothers controlling behaviors were more frequent. Storybook format had no effect on the frequency of mothers’ cognitive scaffolding behaviors (comprehension questions, word help). Relationships between comprehension and shared reading behaviors were examined for each storybook, and although length of the shared reading session and

  15. Screen-film mammography

    International Nuclear Information System (INIS)

    Logan, W.W.; Janus, J.A.

    1987-01-01

    The development of screen-film mammography has resulted in the re-emergence of confidence, rather than fear, in mammography. When screen-film mammography is performed with state-of-the-art dedicated equipment utilizing vigorous breast compression and a ''soft'' x-ray beam for improved contrast, screen-film images are equivalent or superior to those of reduced-dose xeromammography and superior to those of nonscreen film mammography. Technological aids for conversion from xeromammographic or nonscreen film mammographic techniques to screen-film techniques have been described. Screen-film mammography should not be attempted until dedicated equipment has been obtained and the importance of vigorous compression has been understood

  16. UV Suppression by Smearing and Screening Correlators

    OpenAIRE

    Gupta, Sourendu; Karthik, Nikhil

    2013-01-01

    We investigate the mechanism of smearing in the APE, Stout, HYP and HEX schemes through their effect on glue and quark Fourier modes. Using this, we non-perturbatively tune the smearing parameters to their optimum values. Smearing causes a super-linear improvement in taste symmetry breaking in the high temperature phase of QCD. We use optimal smearing in the high temperature phase and find close agreement of meson screening masses with weak coupling predictions.

  17. Engineering aspects of Passavant screening

    International Nuclear Information System (INIS)

    Siddle, K.R.; Sharma, R.K.

    1978-01-01

    The Passavant screen was developed in Europe almost 30 years ago. The Passavant screen is a vertical traveling screen; however, the basic difference between the conventional vertical traveling screen and the Passavant screen is that in the conventional screen water passes through the front screen belt and then the back screen belt, whereas in the Passavant screen the water enters in between the two belts and passes laterally through either of the belts. Thus, theoretically, the screening surface of the Passavant screen is doubled as compared to the same size conventional vertical traveling screen. Various design and operational modifications of the Passavant screen are possible to yield optimum design and performance characteristics which make it amenable to installation at power plants for safe removal of not only fish but also smaller organisms such as fish eggs and larvae. In this paper, details of the screen design and operational characteristics are discussed with notes on how these features can be modified to suit site- and organism-specific requirements

  18. Toxicology screen

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003578.htm Toxicology screen To use the sharing features on this page, please enable JavaScript. A toxicology screen refers to various tests that determine the ...

  19. Mental Health Screening Center

    Science.gov (United States)

    ... Releases & Announcements Public Service Announcements Partnering with DBSA Mental Health Screening Center These online screening tools are not ... you have any concerns, see your doctor or mental health professional. Depression Screening for Adult Depression Screening for ...

  20. Screening history in women with cervical cancer in a Danish population-based screening program

    DEFF Research Database (Denmark)

    Kirschner, Benny; Poll, Susanne; Rygaard, Carsten

    2011-01-01

    The aim of this study was to explore the screening histories of all cervical cancers in a Danish screening population. The intention was to decide suboptimal sides of the screening program and to evaluate the significance of routine screening in the development of cervical cancer.......The aim of this study was to explore the screening histories of all cervical cancers in a Danish screening population. The intention was to decide suboptimal sides of the screening program and to evaluate the significance of routine screening in the development of cervical cancer....

  1. Applying operations research to optimize a novel population management system for cancer screening

    Science.gov (United States)

    Zai, Adrian H; Kim, Seokjin; Kamis, Arnold; Hung, Ken; Ronquillo, Jeremiah G; Chueh, Henry C; Atlas, Steven J

    2014-01-01

    Objective To optimize a new visit-independent, population-based cancer screening system (TopCare) by using operations research techniques to simulate changes in patient outreach staffing levels (delegates, navigators), modifications to user workflow within the information technology (IT) system, and changes in cancer screening recommendations. Materials and methods TopCare was modeled as a multiserver, multiphase queueing system. Simulation experiments implemented the queueing network model following a next-event time-advance mechanism, in which systematic adjustments were made to staffing levels, IT workflow settings, and cancer screening frequency in order to assess their impact on overdue screenings per patient. Results TopCare reduced the average number of overdue screenings per patient from 1.17 at inception to 0.86 during simulation to 0.23 at steady state. Increases in the workforce improved the effectiveness of TopCare. In particular, increasing the delegate or navigator staff level by one person improved screening completion rates by 1.3% or 12.2%, respectively. In contrast, changes in the amount of time a patient entry stays on delegate and navigator lists had little impact on overdue screenings. Finally, lengthening the screening interval increased efficiency within TopCare by decreasing overdue screenings at the patient level, resulting in a smaller number of overdue patients needing delegates for screening and a higher fraction of screenings completed by delegates. Conclusions Simulating the impact of changes in staffing, system parameters, and clinical inputs on the effectiveness and efficiency of care can inform the allocation of limited resources in population management. PMID:24043318

  2. ScreenOS Cookbook

    CERN Document Server

    Brunner, Stefan; Delcourt, David

    2008-01-01

    In the only book that completely covers ScreenOS, six key members of Juniper Network's ScreenOS development team help you troubleshoot secure networks using ScreenOS firewall appliances. Over 200 recipes address a wide range of security issues, provide step-by-step solutions, and include discussions of why the recipes work, so you can easily set up and keep ScreenOS systems on track. The easy-to-follow format enables you to find the topic and specific recipe you need right away.

  3. Screening, Aharonov - Bohm effect, and linking number in spin systems

    International Nuclear Information System (INIS)

    Borisenko, O.; Petrov, K.; Faber, M.

    2000-01-01

    Screening mechanisms and related effects are studied in a variety of spin systems coupled to an external magnetic field. We use a special order parameter which can distinguish between screening due to the kinetic energy of spin excitations and screening due to the magnetic field. The action of this order parameter is based on an analog of the Aharonov - Bohm (AB) effect. The order parameter may test the realization of discrete symmetries embedded into the group symmetry of the theory via probing a nontrivial discrete charge. As simple examples, we study the Gaussian and Ising models. For the latter, we performed also Monte-Carlo simulations for a constant magnetic field. We then apply our results to spin systems with abelian and nonabelian global symmetries in two dimensions and argue that the order parameter proposed could serve as a tool to detect the Berezinskii - Kosterlitz - Thouless (BKT) phase transition

  4. Electromagnetic radiation screening of semiconductor devices for long life applications

    Science.gov (United States)

    Hall, T. C.; Brammer, W. G.

    1972-01-01

    A review is presented of the mechanism of interaction of electromagnetic radiation in various spectral ranges, with various semiconductor device defects. Previous work conducted in this area was analyzed as to its pertinence to the current problem. The task was studied of implementing electromagnetic screening methods in the wavelength region determined to be most effective. Both scanning and flooding type stimulation techniques are discussed. While the scanning technique offers a considerably higher yield of useful information, a preliminary investigation utilizing the flooding approach is first recommended because of the ease of implementation, lower cost and ability to provide go-no-go information in semiconductor screening.

  5. From genes to protein mechanics on a chip.

    Science.gov (United States)

    Otten, Marcus; Ott, Wolfgang; Jobst, Markus A; Milles, Lukas F; Verdorfer, Tobias; Pippig, Diana A; Nash, Michael A; Gaub, Hermann E

    2014-11-01

    Single-molecule force spectroscopy enables mechanical testing of individual proteins, but low experimental throughput limits the ability to screen constructs in parallel. We describe a microfluidic platform for on-chip expression, covalent surface attachment and measurement of single-molecule protein mechanical properties. A dockerin tag on each protein molecule allowed us to perform thousands of pulling cycles using a single cohesin-modified cantilever. The ability to synthesize and mechanically probe protein libraries enables high-throughput mechanical phenotyping.

  6. Self-accelerating universe in Galileon cosmology

    International Nuclear Information System (INIS)

    Silva, Fabio P.; Koyama, Kazuya

    2009-01-01

    We present a cosmological model with a solution that self-accelerates at late times without signs of ghost instabilities on small scales. The model is a natural extension of the Brans-Dicke (BD) theory including a nonlinear derivative interaction, which appears in a theory with the Galilean shift symmetry. The existence of the self-accelerating universe requires a negative BD parameter but, thanks to the nonlinear term, small fluctuations around the solution are stable on small scales. General relativity is recovered at early times and on small scales by this nonlinear interaction via the Vainshtein mechanism. At late time, gravity is strongly modified and the background cosmology shows a phantomlike behavior and the growth rate of structure formation is enhanced. Thus this model leaves distinct signatures in cosmological observations and it can be distinguished from standard LCDM cosmology.

  7. Yeast functional screen to identify genes conferring salt stress tolerance in Salicornia europaea.

    Science.gov (United States)

    Nakahara, Yoshiki; Sawabe, Shogo; Kainuma, Kenta; Katsuhara, Maki; Shibasaka, Mineo; Suzuki, Masanori; Yamamoto, Kosuke; Oguri, Suguru; Sakamoto, Hikaru

    2015-01-01

    Salinity is a critical environmental factor that adversely affects crop productivity. Halophytes have evolved various mechanisms to adapt to saline environments. Salicornia europaea L. is one of the most salt-tolerant plant species. It does not have special salt-secreting structures like a salt gland or salt bladder, and is therefore a good model for studying the common mechanisms underlying plant salt tolerance. To identify candidate genes encoding key proteins in the mediation of salt tolerance in S. europaea, we performed a functional screen of a cDNA library in yeast. The library was screened for genes that allowed the yeast to grow in the presence of 1.3 M NaCl. We obtained three full-length S. europaea genes that confer salt tolerance. The genes are predicted to encode (1) a novel protein highly homologous to thaumatin-like proteins, (2) a novel coiled-coil protein of unknown function, and (3) a novel short peptide of 32 residues. Exogenous application of a synthetic peptide corresponding to the 32 residues improved salt tolerance of Arabidopsis. The approach described in this report provides a rapid assay system for large-scale screening of S. europaea genes involved in salt stress tolerance and supports the identification of genes responsible for such mechanisms. These genes may be useful candidates for improving crop salt tolerance by genetic transformation.

  8. Yeast functional screen to identify genes conferring salt stress tolerance in Salicornia europaea

    Directory of Open Access Journals (Sweden)

    Yoshiki eNakahara

    2015-10-01

    Full Text Available Salinity is a critical environmental factor that adversely affects crop productivity. Halophytes have evolved various mechanisms to adapt to saline environments. Salicornia europaea L. is one of the most salt-tolerant plant species. It does not have special salt-secreting structures like a salt gland or salt bladder, and is therefore a good model for studying the common mechanisms underlying plant salt tolerance. To identify candidate genes encoding key proteins in the mediation of salt tolerance in S. europaea, we performed a functional screen of a cDNA library in yeast. The library was screened for genes that allowed the yeast to grow in the presence of 1.3 M NaCl. We obtained three full-length S. europaea genes that confer salt tolerance. The genes are predicted to encode (1 a novel protein highly homologous to thaumatin-like proteins, (2 a novel coiled-coil protein of unknown function, and (3 a novel short peptide of 32 residues. Exogenous application of a synthetic peptide corresponding to the 32 residues improved salt tolerance of Arabidopsis. The approach described in this report provides a rapid assay system for large-scale screening of S. europaea genes involved in salt stress tolerance and supports the identification of genes responsible for such mechanisms. These genes may be useful candidates for improving crop salt tolerance by genetic transformation.

  9. Quantum probability ranking principle for ligand-based virtual screening

    Science.gov (United States)

    Al-Dabbagh, Mohammed Mumtaz; Salim, Naomie; Himmat, Mubarak; Ahmed, Ali; Saeed, Faisal

    2017-04-01

    Chemical libraries contain thousands of compounds that need screening, which increases the need for computational methods that can rank or prioritize compounds. The tools of virtual screening are widely exploited to enhance the cost effectiveness of lead drug discovery programs by ranking chemical compounds databases in decreasing probability of biological activity based upon probability ranking principle (PRP). In this paper, we developed a novel ranking approach for molecular compounds inspired by quantum mechanics, called quantum probability ranking principle (QPRP). The QPRP ranking criteria would make an attempt to draw an analogy between the physical experiment and molecular structure ranking process for 2D fingerprints in ligand based virtual screening (LBVS). The development of QPRP criteria in LBVS has employed the concepts of quantum at three different levels, firstly at representation level, this model makes an effort to develop a new framework of molecular representation by connecting the molecular compounds with mathematical quantum space. Secondly, estimate the similarity between chemical libraries and references based on quantum-based similarity searching method. Finally, rank the molecules using QPRP approach. Simulated virtual screening experiments with MDL drug data report (MDDR) data sets showed that QPRP outperformed the classical ranking principle (PRP) for molecular chemical compounds.

  10. Quantum probability ranking principle for ligand-based virtual screening.

    Science.gov (United States)

    Al-Dabbagh, Mohammed Mumtaz; Salim, Naomie; Himmat, Mubarak; Ahmed, Ali; Saeed, Faisal

    2017-04-01

    Chemical libraries contain thousands of compounds that need screening, which increases the need for computational methods that can rank or prioritize compounds. The tools of virtual screening are widely exploited to enhance the cost effectiveness of lead drug discovery programs by ranking chemical compounds databases in decreasing probability of biological activity based upon probability ranking principle (PRP). In this paper, we developed a novel ranking approach for molecular compounds inspired by quantum mechanics, called quantum probability ranking principle (QPRP). The QPRP ranking criteria would make an attempt to draw an analogy between the physical experiment and molecular structure ranking process for 2D fingerprints in ligand based virtual screening (LBVS). The development of QPRP criteria in LBVS has employed the concepts of quantum at three different levels, firstly at representation level, this model makes an effort to develop a new framework of molecular representation by connecting the molecular compounds with mathematical quantum space. Secondly, estimate the similarity between chemical libraries and references based on quantum-based similarity searching method. Finally, rank the molecules using QPRP approach. Simulated virtual screening experiments with MDL drug data report (MDDR) data sets showed that QPRP outperformed the classical ranking principle (PRP) for molecular chemical compounds.

  11. Mechanical Biological Treatment

    DEFF Research Database (Denmark)

    Bilitewski, B-; Oros, Christiane; Christensen, Thomas Højlund

    2011-01-01

    The basic processes and technologies of composting and anaerobic digestion, as described in the previous chapters, are usually used for specific or source-separated organic waste flows. However, in the 1990s mechanical biological waste treatment technologies (MBT) were developed for unsorted...... or residual waste (after some recyclables removed at the source). The concept was originally to reduce the amount of waste going to landfill, but MBT technologies are today also seen as plants recovering fuel as well as material fractions. As the name suggests the technology combines mechanical treatment...... technologies (screens, sieves, magnets, etc.) with biological technologies (composting, anaerobic digestion). Two main technologies are available: Mechanical biological pretreatment (MBP), which first removes an RDF fraction and then biologically treats the remaining waste before most of it is landfilled...

  12. Preimplantation genetic screening.

    Science.gov (United States)

    Harper, Joyce C

    2018-03-01

    Preimplantation genetic diagnosis was first successfully performed in 1989 as an alternative to prenatal diagnosis for couples at risk of transmitting a genetic or chromosomal abnormality, such as cystic fibrosis, to their child. From embryos generated in vitro, biopsied cells are genetically tested. From the mid-1990s, this technology has been employed as an embryo selection tool for patients undergoing in vitro fertilisation, screening as many chromosomes as possible, in the hope that selecting chromosomally normal embryos will lead to higher implantation and decreased miscarriage rates. This procedure, preimplantation genetic screening, was initially performed using fluorescent in situ hybridisation, but 11 randomised controlled trials of screening using this technique showed no improvement in in vitro fertilisation delivery rates. Progress in genetic testing has led to the introduction of array comparative genomic hybridisation, quantitative polymerase chain reaction, and next generation sequencing for preimplantation genetic screening, and three small randomised controlled trials of preimplantation genetic screening using these new techniques indicate a modest benefit. Other trials are still in progress but, regardless of their results, preimplantation genetic screening is now being offered globally. In the near future, it is likely that sequencing will be used to screen the full genetic code of the embryo.

  13. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening

    International Nuclear Information System (INIS)

    Scholten, Ernst T.; Horeweg, Nanda; Koning, Harry J. de; Vliegenthart, Rozemarijn; Oudkerk, Matthijs; Mali, Willem P.T.M.; Jong, Pim A. de

    2015-01-01

    To analyse computed tomography (CT) findings of interval and post-screen carcinomas in lung cancer screening. Consecutive interval and post-screen carcinomas from the Dutch-Belgium lung cancer screening trial were included. The prior screening and the diagnostic chest CT were reviewed by two experienced radiologists in consensus with knowledge of the tumour location on the diagnostic CT. Sixty-one participants (53 men) were diagnosed with an interval or post-screen carcinoma. Twenty-two (36 %) were in retrospect visible on the prior screening CT. Detection error occurred in 20 cancers and interpretation error in two cancers. Errors involved intrabronchial tumour (n = 5), bulla with wall thickening (n = 5), lymphadenopathy (n = 3), pleural effusion (n = 1) and intraparenchymal solid nodules (n = 8). These were missed because of a broad pleural attachment (n = 4), extensive reticulation surrounding a nodule (n = 1) and extensive scarring (n = 1). No definite explanation other than human error was found in two cases. None of the interval or post-screen carcinomas involved a subsolid nodule. Interval or post-screen carcinomas that were visible in retrospect were mostly due to detection errors of solid nodules, bulla wall thickening or endobronchial lesions. Interval or post-screen carcinomas without explanation other than human errors are rare. (orig.)

  14. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening

    Energy Technology Data Exchange (ETDEWEB)

    Scholten, Ernst T. [University Medical Centre, Department of Radiology, Utrecht (Netherlands); Kennemer Gasthuis, Department of Radiology, Haarlem (Netherlands); Horeweg, Nanda [Erasmus University Medical Centre, Department of Public Health, Rotterdam (Netherlands); Erasmus University Medical Centre, Department of Pulmonary Medicine, Rotterdam (Netherlands); Koning, Harry J. de [Erasmus University Medical Centre, Department of Public Health, Rotterdam (Netherlands); Vliegenthart, Rozemarijn [University of Groningen, University Medical Centre Groningen, Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Mali, Willem P.T.M.; Jong, Pim A. de [University Medical Centre, Department of Radiology, Utrecht (Netherlands)

    2015-01-15

    To analyse computed tomography (CT) findings of interval and post-screen carcinomas in lung cancer screening. Consecutive interval and post-screen carcinomas from the Dutch-Belgium lung cancer screening trial were included. The prior screening and the diagnostic chest CT were reviewed by two experienced radiologists in consensus with knowledge of the tumour location on the diagnostic CT. Sixty-one participants (53 men) were diagnosed with an interval or post-screen carcinoma. Twenty-two (36 %) were in retrospect visible on the prior screening CT. Detection error occurred in 20 cancers and interpretation error in two cancers. Errors involved intrabronchial tumour (n = 5), bulla with wall thickening (n = 5), lymphadenopathy (n = 3), pleural effusion (n = 1) and intraparenchymal solid nodules (n = 8). These were missed because of a broad pleural attachment (n = 4), extensive reticulation surrounding a nodule (n = 1) and extensive scarring (n = 1). No definite explanation other than human error was found in two cases. None of the interval or post-screen carcinomas involved a subsolid nodule. Interval or post-screen carcinomas that were visible in retrospect were mostly due to detection errors of solid nodules, bulla wall thickening or endobronchial lesions. Interval or post-screen carcinomas without explanation other than human errors are rare. (orig.)

  15. Screening in two-dimensional gauge theories

    International Nuclear Information System (INIS)

    Korcyl, Piotr; Deutsches Elektronen-Synchrotron; Koren, Mateusz

    2012-12-01

    We analyze the problem of screening in 1+1 dimensional gauge theories. Using QED 2 as a warmup for the non-abelian models we show the mechanism of the string breaking, in particular the vanishing overlap of the Wilson loops to the broken-string ground state that has been conjectured in higher-dimensional analyses. We attempt to extend our analysis to non-integer charges in the quenched and unquenched cases, in pursuit of the numerical check of a renowned result for the string tension between arbitrarily-charged fermions in the massive Schwinger model.

  16. Screening in two-dimensional gauge theories

    Energy Technology Data Exchange (ETDEWEB)

    Korcyl, Piotr [Uniwersytet Jagiellonski, Cracow (Poland). Inst. Fizyki; Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Koren, Mateusz [Uniwersytet Jagiellonski, Cracow (Poland). Inst. Fizyki

    2012-12-15

    We analyze the problem of screening in 1+1 dimensional gauge theories. Using QED{sub 2} as a warmup for the non-abelian models we show the mechanism of the string breaking, in particular the vanishing overlap of the Wilson loops to the broken-string ground state that has been conjectured in higher-dimensional analyses. We attempt to extend our analysis to non-integer charges in the quenched and unquenched cases, in pursuit of the numerical check of a renowned result for the string tension between arbitrarily-charged fermions in the massive Schwinger model.

  17. Mechanical design and protection of superconducting magnets

    CERN Document Server

    Asner, Alfred M

    1978-01-01

    The principles of the mechanical design of superconducting magnets of concentric configuration, with iron low-temperature and room- temperature screening, are outlined. Measures for protection of such magnets against quench forces, are considered. (4 refs).

  18. Screen printing technology applied to silicon solar cell fabrication

    Science.gov (United States)

    Thornhill, J. W.; Sipperly, W. E.

    1980-01-01

    The process for producing space qualified solar cells in both the conventional and wraparound configuration using screen printing techniques was investigated. Process modifications were chosen that could be easily automated or mechanized. Work was accomplished to optimize the tradeoffs associated with gridline spacing, gridline definition and junction depth. An extensive search for possible front contact metallization was completed. The back surface field structures along with the screen printed back contacts were optimized to produce open circuit voltages of at least an average of 600 millivolts. After all intended modifications on the process sequence were accomplished, the cells were exhaustively tested. Electrical tests at AMO and 28 C were made before and after boiling water immersion, thermal shock, and storage under conditions of high temperature and high humidity.

  19. Cancer Screening Considerations and Cancer Screening Uptake for Lesbian, Gay, Bisexual, and Transgender Persons.

    Science.gov (United States)

    Ceres, Marc; Quinn, Gwendolyn P; Loscalzo, Matthew; Rice, David

    2018-02-01

    To describe the current state of cancer screening and uptake for lesbian, gay, bisexual, and transgender (LGBT) persons and to propose cancer screening considerations for LGBT persons. Current and historic published literature on cancer screening and LGBT cancer screening; published national guidelines. Despite known cancer risks for members of the LGBT community, cancer screening rates are often low, and there are gaps in screening recommendations for LGBT persons. We propose evidence-based cancer screening considerations derived from the current literature and extant cancer screening recommendations. The oncology nurse plays a key role in supporting patient preventive care and screening uptake through assessment, counseling, education, advocacy, and intervention. As oncology nurses become expert in the culturally competent care of LGBT persons, they can contribute to the improvement of quality of care and overall well-being of this health care disparity population. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Vibration characteristics of an inclined flip-flow screen panel in banana flip-flow screens

    Science.gov (United States)

    Xiong, Xiaoyan; Niu, Linkai; Gu, Chengxiang; Wang, Yinhua

    2017-12-01

    A banana flip-flow screen is an effective solution for the screening of high-viscosity, high-water and fine materials. As one of the key components, the vibration characteristics of the inclined flip-flow screen panel largely affects the screen performance and the processing capacity. In this paper, a mathematical model for the vibration characteristic of the inclined flip-flow screen panel is proposed based on Catenary theory. The reasonability of Catenary theory in analyzing the vibration characteristic of flip-flow screen panels is verified by a published experiment. Moreover, the effects of the rotation speed of exciters, the incline angle, the slack length and the characteristics of the screen on the vertical deflection, the vertical velocity and the vertical acceleration of the screen panel are investigated parametrically. The results show that the rotation speed of exciters, the incline angle, the slack length and the characteristics of the screen have significant effects on the vibrations of an inclined flip-flow screen panel, and these parameters should be optimized.

  1. Cell-Based High-Throughput Screening for Aromatase Inhibitors in the Tox21 10K Library.

    Science.gov (United States)

    Chen, Shiuan; Hsieh, Jui-Hua; Huang, Ruili; Sakamuru, Srilatha; Hsin, Li-Yu; Xia, Menghang; Shockley, Keith R; Auerbach, Scott; Kanaya, Noriko; Lu, Hannah; Svoboda, Daniel; Witt, Kristine L; Merrick, B Alex; Teng, Christina T; Tice, Raymond R

    2015-10-01

    Multiple mechanisms exist for endocrine disruption; one nonreceptor-mediated mechanism is via effects on aromatase, an enzyme critical for maintaining the normal in vivo balance of androgens and estrogens. We adapted the AroER tri-screen 96-well assay to 1536-well format to identify potential aromatase inhibitors (AIs) in the U.S. Tox21 10K compound library. In this assay, screening with compound alone identifies estrogen receptor alpha (ERα) agonists, screening in the presence of testosterone (T) identifies AIs and/or ERα antagonists, and screening in the presence of 17β-estradiol (E2) identifies ERα antagonists. Screening the Tox-21 library in the presence of T resulted in finding 302 potential AIs. These compounds, along with 31 known AI actives and inactives, were rescreened using all 3 assay formats. Of the 333 compounds tested, 113 (34%; 63 actives, 50 marginal actives) were considered to be potential AIs independent of cytotoxicity and ER antagonism activity. Structure-activity analysis suggested the presence of both conventional (eg, 1, 2, 4, - triazole class) and novel AI structures. Due to their novel structures, 14 of the 63 potential AI actives, including both drugs and fungicides, were selected for confirmation in the biochemical tritiated water-release aromatase assay. Ten compounds were active in the assay; the remaining 4 were only active in high-throughput screen assay, but with low efficacy. To further characterize these 10 novel AIs, we investigated their binding characteristics. The AroER tri-screen, in high-throughput format, accurately and efficiently identified chemicals in a large and diverse chemical library that selectively interact with aromatase. © The Author 2015. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. Screen Practice in Curating

    DEFF Research Database (Denmark)

    Toft, Tanya Søndergaard

    2014-01-01

    During the past one and a half decade, a curatorial orientation towards "screen practice" has expanded the moving image and digital art into the public domain, exploring alternative artistic uses of the screen. The emergence of urban LED screens in the late 1990s provided a new venue that allowed...... for digital art to expand into public space. It also offered a political point of departure, inviting for confrontation with the Spectacle and with the politics and ideology of the screen as a mass communication medium that instrumentalized spectator positions. In this article I propose that screen practice...... to the dispositif of screen practice in curating, resulting in a medium-based curatorial discourse. With reference to the nomadic exhibition project Nordic Outbreak that I co-curated with Nina Colosi in 2013 and 2014, I suggest that the topos of the defined visual display area, frequently still known as "the screen...

  3. Breast cancer screening-opportunistic use of registry and linked screening data for local evaluation.

    Science.gov (United States)

    Roder, David; Farshid, Gelareh; Gill, Grantley; Kollias, Jim; Koczwara, Bogda; Karapetis, Chris; Adams, Jacqui; Joshi, Rohit; Keefe, Dorothy; Powell, Kate; Fusco, Kellie; Eckert, Marion; Buckley, Elizabeth; Beckmann, Kerri

    2017-06-01

    Screening has been found to reduce breast cancer mortality at a population level in Australia, but these studies did not address local settings where numbers of deaths would generally have been too low for evaluation. Clinicians, administrators, and consumer groups are also interested in local service outcomes. We therefore use more common prognostic and treatment measures and survivals to gain evidence of screening effects among patients attending 4 local hospitals for treatment. To compare prognostic, treatment, and survival measures by screening history to determine whether expected screening effects are occurring. Employing routine clinical registry and linked screening data to investigate associations of screening history with these measures, using unadjusted and adjusted analyses. Screened women had a 10-year survival from breast cancer of 92%, compared with 78% for unscreened women; and 79% of screened surgical cases had breast conserving surgery compared with 64% in unscreened women. Unadjusted analyses indicated that recently screened cases had earlier tumor node metastasis stages, smaller diameters, less nodal involvement, better tumor differentiation, more oestrogen and progesterone receptor positive lesions, more hormone therapy, and less chemotherapy. Radiotherapy tended to be more common in screening participants. More frequent use of adjunctive radiotherapy applied when breast conserving surgery was used. Results confirm the screening effects expected from the scientific literature and demonstrate the value of opportunistic use of available registry and linked screening data for indicating to local health administrations, practitioners, and consumers whether local screening services are having the effects expected. © 2016 John Wiley & Sons, Ltd.

  4. Pediatric blunt cerebrovascular injury: the McGovern screening score.

    Science.gov (United States)

    Herbert, Joseph P; Venkataraman, Sidish S; Turkmani, Ali H; Zhu, Liang; Kerr, Marcia L; Patel, Rajan P; Ugalde, Irma T; Fletcher, Stephen A; Sandberg, David I; Cox, Charles S; Kitagawa, Ryan S; Day, Arthur L; Shah, Manish N

    2018-03-16

    OBJECTIVE The objective of this study was to assess the incidence, diagnosis, and treatment of pediatric blunt cerebrovascular injury (BCVI) at a busy Level 1 trauma center and to develop a tool for accurately predicting pediatric BCVI and the need for diagnostic testing. METHODS This is a retrospective cohort study of a prospectively collected database of pediatric patients who had sustained blunt trauma (patient age range 0-15 years) and were treated at a Level 1 trauma center between 2005 and 2015. Digital subtraction angiography, MR angiography, or CT angiography was used to confirm BCVI. Recently, the Utah score has emerged as a screening tool specifically targeted toward evaluating BCVI risk in the pediatric population. Using logistical regression and adding mechanism of injury as a logit, the McGovern score was able to use the Utah score as a starting point to create a more sensitive screening tool to identify which pediatric trauma patients should receive angiographic imaging due to a high risk for BCVI. RESULTS A total of 12,614 patients (mean age 6.6 years) were admitted with blunt trauma and prospectively registered in the trauma database. Of these, 460 (3.6%) patients underwent angiography after blunt trauma: 295 (64.1%), 107 (23.3%), 6 (1.3%), and 52 (11.3%) patients underwent CT angiography, MR angiography, digital subtraction angiography, and a combination of imaging modalities, respectively. The BCVI incidence (n = 21; 0.17%) was lower than that in a comparable adult group (p tools for BCVI, misclassified 6 (28.6%), 6 (28.6%), 7 (33.3%), and 10 (47.6%) patients with BCVI, respectively, as "low risk" and not in need of subsequent angiographic imaging. By incorporating the mechanism of injury into the score, the McGovern score only misclassified 4 (19.0%) children, all of whom were managed conservatively with no treatment or aspirin. CONCLUSIONS With a low incidence of pediatric BCVI and a nonsurgical treatment paradigm, a more conservative approach

  5. Molecular HIV screening.

    Science.gov (United States)

    Bourlet, Thomas; Memmi, Meriam; Saoudin, Henia; Pozzetto, Bruno

    2013-09-01

    Nuclear acid testing is more and more used for the diagnosis of infectious diseases. This paper focuses on the use of molecular tools for HIV screening. The term 'screening' will be used under the meaning of first-line HIV molecular techniques performed on a routine basis, which excludes HIV molecular tests designed to confirm or infirm a newly discovered HIV-seropositive patient or other molecular tests performed for the follow-up of HIV-infected patients. The following items are developed successively: i) presentation of the variety of molecular tools used for molecular HIV screening, ii) use of HIV molecular tools for the screening of blood products, iii) use of HIV molecular tools for the screening of organs and tissue from human origin, iv) use of HIV molecular tools in medically assisted procreation and v) use of HIV molecular tools in neonates from HIV-infected mothers.

  6. Colorectal Cancer Screening

    OpenAIRE

    Quintero, Enrique; Saito, Yutaka; Hassan, Cessare; Senore, Carlo

    2012-01-01

    Colorectal cancer, which is the leading cancer in Singapore, can be prevented by increased use of screening and polypectomy. A range of screening strategies such as stool-based tests, flexible sigmoidoscopy, colonoscopy and computed tomography colonography are available, each with different strengths and limitations. Primary care physicians should discuss appropriate screening modalities with their patients, tailored to their individual needs. Physicians, patients and the government should wo...

  7. Screening of cellular proteins that interact with the classical swine ...

    Indian Academy of Sciences (India)

    In the current study, aiming to find more clues in understanding the molecular mechanisms of CSFV NS5A's function, the yeast two-hybrid (Y2H) system was adopted to screen for CSFV NS5A interactive proteins in the cDNA library of the swine umbilical vein endothelial cell (SUVEC). Alignment with the NCBI database ...

  8. QCD contributions to vacuum polarization

    International Nuclear Information System (INIS)

    Reinders, L.J.; Rubinstein, H.R.; Yazaki, S.

    1980-01-01

    We have computed to lowest non-trivial order the perturbative and non-perturbative contributions to the vacuum polarization from all currents up to and including spin 2 ++ . These expressions are important, for example to evaluate QCD sum rules for heavy and light quark systems as shown by Shifman, Vainshtein and Zakharov. Most of the known ones are verified, one slightly changed, and many new ones are displayed. (orig.)

  9. Screen dealing

    International Nuclear Information System (INIS)

    Barlow, J.W.

    1991-01-01

    The screen dealing system provides a facility whereby buyers and sellers of spot thermal coal can make bids and offers via the medium of the Reuters screen. A sale results when a market participant notifies his acceptance of a price to a central dealing desk. Use of the system is available to all genuine participants in the coal trade. This paper reports that it provides a focus for information and for the visible making of coal prices. For years screen trading has been used successfully to trade other commodities. At last coal is being traded electronically. It makes sense. It works. Users like it

  10. Screen time and children

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000355.htm Screen time and children To use the sharing features on ... videos is considered unhealthy screen time. Current Screen Time Guidelines Children under age 2 should have no ...

  11. Screening for abdominalt aortaaneurisme

    DEFF Research Database (Denmark)

    Lindholt, J S; Juul, Svend; Henneberg, E W

    1997-01-01

    rupture. Ultrasonographic screening for AAA takes 10 minutes per scan, and the sensitivity and specificity are high. Ultrasonographic screening for AAA is a reliable, safe and inexpensive method for screening, and screening for AAA is discussed worldwide. One point four percent of deaths among men from 65...... to 80 year of age are caused by ruptured AAA. Screening men over 65 for AAA can theoretically prevent a substantial number of deaths. Our calculations predict one prevented AAA-death per 200-300 scans for a cost of about 4000 DKK per saved year of life. However, cost-benefit analyses are based...... on uncertain assumptions concerning prevalence, incidence and risk of rupture. Therefore a randomized trial screening of 65-73 year old males is taking place in the County of Viborg in Denmark. Udgivelsesdato: 1997-Mar-24...

  12. Genome-Wide RNAi Ionomics Screen Reveals New Genes and Regulation of Human Trace Element Metabolism

    OpenAIRE

    Malinouski, Mikalai; Hasan, Nesrin M.; Zhang, Yan; Seravalli, Javier; Lin, Jie; Avanesov, Andrei; Lutsenko, Svetlana; Gladyshev, Vadim N.

    2017-01-01

    Trace elements are essential for human metabolism and dysregulation of their homeostasis is associated with numerous disorders. Here we characterize mechanisms that regulate trace elements in human cells by designing and performing a genome-wide high-throughput siRNA/ionomics screen, and examining top hits in cellular and biochemical assays. The screen reveals high stability of the ionomes, especially the zinc ionome, and yields known regulators and novel candidates. We further uncover fundam...

  13. Screening of Duchenne muscular dystrophy (DMD mutations and investigating its mutational mechanism in Chinese patients.

    Directory of Open Access Journals (Sweden)

    Chen Chen

    Full Text Available Duchenne muscular dystrophy (DMD is a common X-linked recessive disease of muscle degeneration and death. In order to provide accurate and reliable genetic counseling and prenatal diagnosis, we screened DMD mutations in a cohort of 119 Chinese patients using multiplex ligation-dependent probe amplification (MLPA and denaturing high performance liquid chromatography (DHPLC followed by Sanger sequencing. In these unrelated DMD patients, we identified 11 patients with DMD small mutations (9.2% and 81 patients with DMD deletions/duplications (del/dup (68.1%, of which 64 (79.0% were deletions, 16 (19.8% were duplications, and one (1.2% was both deletion and duplication. Furthermore, we analyzed the frequency of DMD breakpoint in the 64 deletion cases by calculating exon-deletion events of certain exon interval that revealed a novel mutation hotspot boundary. To explore why DMD rearrangement breakpoints were predisposed to specific regions (hotspot, we precisely characterized junction sequences of breakpoints at the nucleotide level in 21 patients with exon deleted/duplicated in DMD with a high-resolution SNP microarray assay. There were no exactly recurrent breakpoints and there was also no significant difference between single-exon del/dup and multiple-exon del/dup cases. The data from the current study provided a comprehensive strategy to detect DMD mutations for clinical practice, and identified two deletion hotspots at exon 43-55 and exon 10-23 by calculating exon-deletion events of certain exon interval. Furthermore, this is the first study to characterize DMD breakpoint at the nucleotide level in a Chinese population. Our observations provide better understanding of the mechanism for DMD gene rearrangements.

  14. Breast Cancer Screening

    International Nuclear Information System (INIS)

    Altaf, Fadwa J.

    2004-01-01

    Breast cancer is a very common health problem in Saudi females that can be reduced by early detection through introducing breast cancer screening. Literature review reveals significant reduction in breast cancer incidence and outcome after the beginning of breast cancer screening. The objectives of this article are to highlight the significance of breast cancer screening in different international societies and to write the major guidelines of breast cancer screening in relation to other departments involved with more emphasis on the Pathology Department guidelines in tissue handling, diagnostic criteria and significance of the diagnosis. This article summaries and acknowledges major work carried out before, and recommends similar modified work in order to meet the requirement for the Saudi society. (author)

  15. Stomach (Gastric) Cancer Screening

    Science.gov (United States)

    ... Stomach Cancer Prevention Stomach Cancer Screening Research Stomach (Gastric) Cancer Screening (PDQ®)–Patient Version What is screening? Go ... are called diagnostic tests . General Information About Stomach (Gastric) Cancer Key Points Stomach cancer is a disease in ...

  16. Gas-Foamed Scaffold Gradients for Combinatorial Screening in 3D

    Directory of Open Access Journals (Sweden)

    Joachim Kohn

    2012-03-01

    Full Text Available Current methods for screening cell-material interactions typically utilize a two-dimensional (2D culture format where cells are cultured on flat surfaces. However, there is a need for combinatorial and high-throughput screening methods to systematically screen cell-biomaterial interactions in three-dimensional (3D tissue scaffolds for tissue engineering. Previously, we developed a two-syringe pump approach for making 3D scaffold gradients for use in combinatorial screening of salt-leached scaffolds. Herein, we demonstrate that the two-syringe pump approach can also be used to create scaffold gradients using a gas-foaming approach. Macroporous foams prepared by a gas-foaming technique are commonly used for fabrication of tissue engineering scaffolds due to their high interconnectivity and good mechanical properties. Gas-foamed scaffold gradient libraries were fabricated from two biodegradable tyrosine-derived polycarbonates: poly(desaminotyrosyl-tyrosine ethyl ester carbonate (pDTEc and poly(desaminotyrosyl-tyrosine octyl ester carbonate (pDTOc. The composition of the libraries was assessed with Fourier transform infrared spectroscopy (FTIR and showed that pDTEc/pDTOc gas-foamed scaffold gradients could be repeatably fabricated. Scanning electron microscopy showed that scaffold morphology was similar between the pDTEc-rich ends and the pDTOc-rich ends of the gradient. These results introduce a method for fabricating gas-foamed polymer scaffold gradients that can be used for combinatorial screening of cell-material interactions in 3D.

  17. Screening vs. non-screening detected colorectal cancer: Differences in pre-therapeutic work up and treatment.

    Science.gov (United States)

    Saraste, D; Martling, A; Nilsson, P J; Blom, J; Törnberg, S; Janson, M

    2017-06-01

    Objectives To compare preoperative staging, multidisciplinary team-assessment, and treatment in patients with screening detected and non-screening detected colorectal cancer. Methods Data on patient and tumour characteristics, staging, multidisciplinary team-assessment and treatment in patients with screening and non-screening detected colorectal cancer from 2008 to 2012 were collected from the Stockholm-Gotland screening register and the Swedish Colorectal Cancer Registry. Results The screening group had a higher proportion of stage I disease (41 vs. 15%; p team-assessed than the non-screening group ( p team-assessed than patients with surgically resected cancers ( p team assessed more extensively than patients with non-screening detected cancers. Staging and multidisciplinary team assessment prior to endoscopic resection was less complete compared with surgical resection. Extensive surgical and (neo)adjuvant treatment was given in stage I disease. Participation in screening reduced the risk of emergency surgery for colorectal cancer.

  18. Rheological behavior of silver nanowire conductive inks during screen printing

    Science.gov (United States)

    Hemmati, Shohreh; Barkey, Dale P.; Gupta, Nivedita

    2016-08-01

    The rheological behavior of silver nanowire (AgNW) suspensions adapted for screen printing inks was investigated. Aqueous silver nanowire inks consisting of AgNW (length of 30 μm, and diameter of 40 and 90 nm), dispersant and binder were formulated. The effect of AgNW content on the rheological behavior of the ink and the build-up of ink structure after screen printing were examined as they depend on applied shear and temperature. Rheological measurements under conditions that mimic the screen printing process were done to assess viscoelastic properties induced by flow alignment of the wires and the subsequent recovery of the low shear structure. The Stretched Exponential model (SEmo) was used to model the recovery process after screen printing to obtain the characteristic time of the recovery or build-up process. The characteristic time was determined at several temperatures to obtain the activation energy of recovery. The domination of Brownian motion or non-Brownian motion behavior can be characterized by a Peclet number, which is the ratio of shear rate to the rotational diffusion coefficient. The Peclet number and the dimensionless concentration of wires were used to assess the recovery mechanism. The steady viscosity at low and high shear rates was also treated by an activation energy analysis.

  19. Rheological behavior of silver nanowire conductive inks during screen printing

    International Nuclear Information System (INIS)

    Hemmati, Shohreh; Barkey, Dale P.; Gupta, Nivedita

    2016-01-01

    The rheological behavior of silver nanowire (AgNW) suspensions adapted for screen printing inks was investigated. Aqueous silver nanowire inks consisting of AgNW (length of 30 μm, and diameter of 40 and 90 nm), dispersant and binder were formulated. The effect of AgNW content on the rheological behavior of the ink and the build-up of ink structure after screen printing were examined as they depend on applied shear and temperature. Rheological measurements under conditions that mimic the screen printing process were done to assess viscoelastic properties induced by flow alignment of the wires and the subsequent recovery of the low shear structure. The Stretched Exponential model (SEmo) was used to model the recovery process after screen printing to obtain the characteristic time of the recovery or build-up process. The characteristic time was determined at several temperatures to obtain the activation energy of recovery. The domination of Brownian motion or non-Brownian motion behavior can be characterized by a Peclet number, which is the ratio of shear rate to the rotational diffusion coefficient. The Peclet number and the dimensionless concentration of wires were used to assess the recovery mechanism. The steady viscosity at low and high shear rates was also treated by an activation energy analysis.

  20. Rheological behavior of silver nanowire conductive inks during screen printing

    Energy Technology Data Exchange (ETDEWEB)

    Hemmati, Shohreh; Barkey, Dale P., E-mail: dpb@unh.edu; Gupta, Nivedita [University of New Hampshire, Department of Chemical Engineering (United States)

    2016-08-15

    The rheological behavior of silver nanowire (AgNW) suspensions adapted for screen printing inks was investigated. Aqueous silver nanowire inks consisting of AgNW (length of 30 μm, and diameter of 40 and 90 nm), dispersant and binder were formulated. The effect of AgNW content on the rheological behavior of the ink and the build-up of ink structure after screen printing were examined as they depend on applied shear and temperature. Rheological measurements under conditions that mimic the screen printing process were done to assess viscoelastic properties induced by flow alignment of the wires and the subsequent recovery of the low shear structure. The Stretched Exponential model (SEmo) was used to model the recovery process after screen printing to obtain the characteristic time of the recovery or build-up process. The characteristic time was determined at several temperatures to obtain the activation energy of recovery. The domination of Brownian motion or non-Brownian motion behavior can be characterized by a Peclet number, which is the ratio of shear rate to the rotational diffusion coefficient. The Peclet number and the dimensionless concentration of wires were used to assess the recovery mechanism. The steady viscosity at low and high shear rates was also treated by an activation energy analysis.

  1. Values in breast cancer screening: an empirical study with Australian experts

    Science.gov (United States)

    Parker, Lisa; Rychetnik, Lucie; Carter, Stacy

    2015-01-01

    Objective To explore what Australian experts value in breast screening, how these values are conceptualised and prioritised, and how they inform experts’ reasoning and judgement about the Australian breast-screening programme. Design Qualitative study based on interviews with experts. Participants 33 experts, including clinicians, programme managers, policymakers, advocates and researchers selected for their recognisable influence in the Australian breast-screening setting. Setting Australian breast-screening policy, practice and research settings. Results Experts expressed 2 types of values: ethical values (about what was good, important or right) and epistemological values (about how evidence should be created and used). Ethical values included delivering benefit, avoiding harm, promoting autonomy, fairness, cost effectiveness, accountability, professionalism and transparency. Epistemological values informed experts’ arguments about prioritising and evaluating evidence methodology, source population and professional interests. Some values were conceptualised differently by experts: for example, delivering benefit could mean reducing breast cancer mortality, reducing all-cause mortality, reducing mortality in younger women, reducing need for aggressive treatment, and/or reassuring women they were cancer free. When values came into conflict, experts prioritised them differently: for example, when experts perceived a conflict between delivering benefits and promoting autonomy, there were differences in which value was prioritised. We explain the complexity of the relationship between held values and experts’ overall views on breast cancer screening. Conclusions Experts’ positions in breast screening are influenced by evidence and a wide range of ethical and epistemological values. We conclude that discussions about values should be a regular part of breast-screening review in order to build understanding between those who hold different positions, and

  2. Colorectal cancer screening

    OpenAIRE

    Plumb, A. A.; Halligan, S.

    2015-01-01

    Colorectal cancer is a major public health burden worldwide. There is clear-cut evidence that screening will reduce colorectal cancer mortality and the only contentious issue is which screening tool to use. Most evidence points towards screening with fecal occult blood testing. The immunochemical fecal occult blood tests have a higher sensitivity than the guaiac-based tests. In addition, their automation and haemoglobin quantification allows a threshold for colonoscopy to be selected that can...

  3. High-throughput screening of chemical effects on ...

    Science.gov (United States)

    Disruption of steroidogenesis by environmental chemicals can result in altered hormone levels causing adverse reproductive and developmental effects. A high-throughput assay using H295R human adrenocortical carcinoma cells was used to evaluate the effect of 2,060 chemical samples on steroidogenesis via HPLC-MS/MS quantification of 10 steroid hormones, including progestagens, glucocorticoids, androgens, and estrogens. The study employed a three stage screening strategy. The first stage established the maximum tolerated concentration (MTC; >70% viability) per sample. The second stage quantified changes in hormone levels at the MTC while the third stage performed concentration-response (CR) on a subset of samples. At all stages, cells were pre-stimulated with 10 µM forskolin for 48 h to induce steroidogenesis followed by chemical treatment for 48 h. Of the 2,060 chemical samples evaluated, 524 samples were selected for six-point CR screening, based in part on significantly altering at least 4 hormones at the MTC. CR screening identified 232 chemical samples with concentration-dependent effects on 17β-estradiol and/or testosterone, with 411 chemical samples showing an effect on at least one hormone across the steroidogenesis pathway. Clustering of the concentration-dependent chemical-mediated steroid hormone effects grouped chemical samples into five distinct profiles generally representing putative mechanisms of action, including CYP17A1 and HSD3B inhibition. A d

  4. Retinopathy of prematurity screening criteria in Iran: new screening guidelines.

    Science.gov (United States)

    Roohipoor, Ramak; Karkhaneh, Reza; Farahani, Afsar; Ebrahimiadib, Nazanin; Modjtahedi, Bobeck; Fotouhi, Akbar; Yaseri, Mehdi; Khodabande, Alireza; Zarei, Mohammad; Imani Fuladi, Marjan; Taheri, Arash; Riazi Esfahani, Mohammad; Loewenstein, John

    2016-07-01

    To test the applicability of existing retinopathy of prematurity (ROP) guidelines on Iranian patients and to develop novel ROP screening criteria in Iran. Both eyes of 1932 infants born ≤37 weeks of gestation and/or weighting ≤3000 g were included in this prospective cohort study that was conducted across nine neonatal intensive care units and a tertiary eye hospital ROP clinic. The patients were examined for ROP and the need for treatment (type 1 ROP or worse). All the patients were screened 4 weeks after birth or at 31 weeks of postmenstrual age, whichever was later. The patients were followed until retinal vascularisation was completed or the patients reached 50 weeks of gestational age (GA) without prethreshold ROP. A receiver operating characteristic curve was used to determine the best screening criteria for ROP. Screening criteria from other countries were applied to our patient data to determine their ability to appropriately detect ROP. Patients with ROP requiring treatment. The mean GA±SD and birth weight (BW)±SD of the screened patients were 32±2.7 weeks and 1713±516 g, respectively. Using criteria of GA≤32 weeks or BW ≤2000 yielded sensitivity and specificity of 100% and 26.7%, respectively, for treatment requiring ROP regardless of clinical comorbidities. Using screening recommendations of American Academy of Pediatrics would miss 25.4% of ROP and 8.4%ROP requiring treatment in our cohort. Other countries screening recommendations would result in a significant amount of missed cases of treatment requiring ROP when applied to Iran. As a result, we have proposed new guidelines for premature babies in Iran. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. High-content screening of small compounds on human embryonic stem cells.

    Science.gov (United States)

    Barbaric, Ivana; Gokhale, Paul J; Andrews, Peter W

    2010-08-01

    Human ES (embryonic stem) cells and iPS (induced pluripotent stem) cells have been heralded as a source of differentiated cells that could be used in the treatment of degenerative diseases, such as Parkinson's disease or diabetes. Despite the great potential for their use in regenerative therapy, the challenge remains to understand the basic biology of these remarkable cells, in order to differentiate them into any functional cell type. Given the scale of the task, high-throughput screening of agents and culture conditions offers one way to accelerate these studies. The screening of small-compound libraries is particularly amenable to such high-throughput methods. Coupled with high-content screening technology that enables simultaneous assessment of multiple cellular features in an automated and quantitative way, this approach is proving powerful in identifying both small molecules as tools for manipulating stem cell fates and novel mechanisms of differentiation not previously associated with stem cell biology. Such screens performed on human ES cells also demonstrate the usefulness of human ES/iPS cells as cellular models for pharmacological testing of drug efficacy and toxicity, possibly a more imminent use of these cells than in regenerative medicine.

  6. Digital breast tomosynthesis (3D-mammography) screening: A pictorial review of screen-detected cancers and false recalls attributed to tomosynthesis in prospective screening trials.

    Science.gov (United States)

    Houssami, Nehmat; Lång, Kristina; Bernardi, Daniela; Tagliafico, Alberto; Zackrisson, Sophia; Skaane, Per

    2016-04-01

    This pictorial review highlights cancers detected only at tomosynthesis screening and screens falsely recalled in the course of breast tomosynthesis screening, illustrating both true-positive (TP) and false-positive (FP) detection attributed to tomosynthesis. Images and descriptive data were used to characterise cases of screen-detection with tomosynthesis, sourced from prospective screening trials that performed standard (2D) digital mammography (DM) and tomosynthesis (3D-mammography) in the same screening participants. Exemplar cases from four trials highlight common themes of relevance to screening practice including: the type of lesions frequently made more conspicuous or perceptible by tomosynthesis (spiculated masses, and architectural distortions); the histologic findings (both TP and FP) of tomosynthesis-only detection; and the need to extend breast work-up protocols (additional imaging including ultrasound and MRI, and tomosynthesis-guided biopsy) if tomosynthesis is adopted for primary screening. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Biological Evaluations of an Off-Stream Channel, Horizontal Flat-Plate Fish Screen-The Farmers Screen

    Science.gov (United States)

    Mesa, Matthew G.; Rose, Brien P.; Copeland, Elizabeth S.

    2010-01-01

    Screens are commonly installed at water diversion sites to reduce entrainment of fish. Recently, the Farmers Irrigation District in Hood River, Oregon, developed a new flat-plate screen design that offers passive operation and may result in reduced operation and installation costs to irrigators. To evaluate the performance (its biological effect on fish) of this type of screen, two size classes of juvenile coho salmon (Oncorhynchus kistuch) were released over a small version of this screen in the field-the Herman Creek screen. The performance of the screen was evaluated over a range of inflow [0.02 to 0.42 m3/s (cubic meters per second)] and diversion flows (0.02 to 0.34 m3/s) at different weir wall heights. The mean approach velocities for the screen ranged from 0 to 5 cm/s (centimeters per second) and mean sweeping velocities ranged from 36 to 178 cm/s. Water depths over the screen surface ranged from 1 to 25 centimeters and were directly related to weir wall height and inflow. Passage of juvenile coho salmon over the screen under a variety of hydraulic conditions did not severely injure them or cause delayed mortality. For all fish, the mean percentage of body surface area that was injured after passage over the screen ranged from about 0.4 to 3.0%. This occurred even though many fish contacted the screen surface during passage. No fish were observed becoming impinged on the screen surface (greater than 1 second contact with the screen). When operated within its design criteria (diversion flows of about 0.28 m3/s), the screen provided safe and effective downstream passage of juvenile salmonids under a variety of hydraulic conditions. However, we do not recommend operating the screen at inflows less than 0.14 m3/s (5 ft3/s) because water depth can get quite shallow and the screen can completely dewater, particularly at very low flows.

  8. Screening for Glaucoma

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Glaucoma The U.S. Preventive Services Task Force (Task Force) has issued a final recommendation statement on Screening for Glaucoma . This final recommendation statement ...

  9. Expanded Newborn Screening Program in Saudi Arabia: Incidence of screened disorders.

    Science.gov (United States)

    Alfadhel, Majid; Al Othaim, Ali; Al Saif, Saif; Al Mutairi, Fuad; Alsayed, Moeenaldeen; Rahbeeni, Zuhair; Alzaidan, Hamad; Alowain, Mohammed; Al-Hassnan, Zuhair; Saeedi, Mohamad; Aljohery, Saeed; Alasmari, Ali; Faqeih, Eissa; Alwakeel, Mansour; AlMashary, Maher; Almohameed, Sulaiman; Alzahrani, Mohammed; Migdad, Abeer; Al-Dirbashi, Osama Y; Rashed, Mohamed; Alamoudi, Mohamed; Jacob, Minnie; Alahaidib, Lujane; El-Badaoui, Fahd; Saadallah, Amal; Alsulaiman, Ayman; Eyaid, Wafaa; Al-Odaib, Ali

    2017-06-01

    To address the implementation of the National Newborn Screening Program (NBS) in Saudi Arabia and stratify the incidence of the screened disorders. A retrospective study conducted between 1 August 2005 and 31 December 2012, total of 775 000 newborns were screened from 139 hospitals distributed among all regions of Saudi Arabia. The NBS Program screens for 16 disorders from a selective list of inborn errors of metabolism (IEM) and endocrine disorders. Heel prick dry blood spot samples were obtained from all newborns for biochemical and immunoassay testing. Recall screening testing was performed for Initial positive results and confirmed by specific biochemical assays. A total of 743 cases were identified giving an overall incidence of 1:1043. Frequently detected disorders nationwide were congenital hypothyroidism and congenital adrenal hyperplasia with an incidence of 1:7175 and 1:7908 correspondingly. The highest incidence among the IEM was propionic acidaemia with an incidence rate of 1:14 000. The article highlights the experience of the NBS Program in Saudi Arabia and providing data on specific regional incidences of all the screened disorders included in the programme; and showed that the incidence of these disorders is one of the highest reported so far world-wide. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  10. Breast cancer screening

    International Nuclear Information System (INIS)

    Vandenbroucke, A.

    1987-01-01

    Many studies have shown that breast cancer screening is able to reduce breast cancer mortality, including the HIP study, the Swedish Trial and the Netherlands studies. Mammography is considered as the most effective method for breast cancer screening but it might be unfeasible for some reasons: - the population acceptability of the method might be low. Indeed, most populations of the South of Europe are less compliant to mass screening than populations of the North of Europe; - the medical equipment and personnel - radiologists and pathologists - might be insufficient; - it might be too costly for the National Health Service, specially where the incidence rate of breast cancer is relatively low (i.e. Greece, Portugal). The validity of screening tests is judged by their sensitivity and their specificity

  11. Does digital mammography in a decentralized breast cancer screening program lead to screening performance parameters comparable with film-screen mammography?

    International Nuclear Information System (INIS)

    Ongeval, Chantal van; Steen, Andre van; Zanca, Federica; Bosmans, Hilde; Marchal, Guy; Putte, Gretel vande; Limbergen, Erik van

    2010-01-01

    To evaluate if the screening performance parameters of digital mammography (DM) in a decentralized screening organization were comparable with film-screen mammography (FSM). A nationwide screening program was launched in 2001, and since 2005 screening with DM has been allowed. Firstly, the parameters of the three regional screening units (RSUs) that first switched to DM (11,355 women) were compared with the FSM period of the same three RSUs (23,325 women). Secondly, they were compared with the results of the whole central breast unit (CBU). The recall rate (RR) of the DM group in the initial round was 2.64% [2.40% for FSM (p = 0.43)] and in the subsequent round 1.20% [1.58% for FSM (p = 0.03)]. The cancer detection rate (CDR) was 0.59% for DM and 0.64% for FSM (p = 0.56). The percentage of ductal carcinoma in situ was 0.07% for DM and 0.16% for FSM (p = 0.02). The positive predictive value was high in the subsequent rounds (DM 48.00%, FSM 45.93%) and lower in the initial round (DM 24.05%, FSM 24.86%). Compared with the results of the whole CBU, DM showed no significant difference. DM can be introduced in a decentralized screening organization with a high CDR without increasing the RR. (orig.)

  12. A retrospective audit of the first screening round of the Maltese breast screening programme

    International Nuclear Information System (INIS)

    Mizzi, D.; Zarb, F.; Dennis, A.

    2017-01-01

    Purpose: To analyse whether the screening performance parameters of the Maltese National Breast Screening Programme first screening round met requirements set by European standards. The association between screening age and results of screening performance parameters was also investigated. Method: Quantitative methodology was used to review examinations of women who were recalled for a technical recall or further assessment rates. All accessible members of the population recalled during the first round were retrospectively reviewed resulting in a sample of 2300 recalled examinations. Results: Malta's first screening round met the European Guidelines recommendations for technical repeat rate (0.26%), early recall rate (0.45%), breast cancer detection rate (13.77 per 1000 women) and Positive Predictive Value of screening test (7.58%). However, local recall rate (18.53%) and further assessment rate (18.27%) were higher than recommended. The Chi square test showed a statistically significant difference (p ≤ 0.05) in recall rates between the compared age groups, as younger women (51–55 years) were more likely to have a negative diagnosis after the initial mammogram whereas older women (56–60 years) were more likely to be recalled. There was no age discrepancy (p ≥ 0.05) in local breast cancer detection rate and positive predictive value of screening test. Conclusion: Although the Maltese first screening round performed well, this study found deficiencies in recall and further assessment rates, which according to literature may result in psychological morbidity and inefficient use of screening resources. This study also concluded that when a cohort is analysed, age is not as significant as the screening round itself (first/subsequent). - Highlights: • The Maltese technical and early recall rates complied with European guidelines. • Breast cancer detection rate and positive predictive value conformed to guidelines. • The recall and further

  13. Extending applicability of bimetric theory: chameleon bigravity

    Science.gov (United States)

    De Felice, Antonio; Mukohyama, Shinji; Uzan, Jean-Philippe

    2018-02-01

    This article extends bimetric formulations of massive gravity to make the mass of the graviton to depend on its environment. This minimal extension offers a novel way to reconcile massive gravity with local tests of general relativity without invoking the Vainshtein mechanism. On cosmological scales, it is argued that the model is stable and that it circumvents the Higuchi bound, hence relaxing the constraints on the parameter space. Moreover, with this extension the strong coupling scale is also environmentally dependent in such a way that it is kept sufficiently higher than the expansion rate all the way up to the very early universe, while the present graviton mass is low enough to be phenomenologically interesting. In this sense the extended bigravity theory serves as a partial UV completion of the standard bigravity theory. This extension is very generic and robust and a simple specific example is described.

  14. Screening for skin cancer.

    Science.gov (United States)

    Helfand, M; Mahon, S M; Eden, K B; Frame, P S; Orleans, C T

    2001-04-01

    Malignant melanoma is often lethal, and its incidence in the United States has increased rapidly over the past 2 decades. Nonmelanoma skin cancer is seldom lethal, but, if advanced, can cause severe disfigurement and morbidity. Early detection and treatment of melanoma might reduce mortality, while early detection and treatment of nonmelanoma skin cancer might prevent major disfigurement and to a lesser extent prevent mortality. Current recommendations from professional societies regarding screening for skin cancer vary. To examine published data on the effectiveness of routine screening for skin cancer by a primary care provider, as part of an assessment for the U.S. Preventive Services Task Force. We searched the MEDLINE database for papers published between 1994 and June 1999, using search terms for screening, physical examination, morbidity, and skin neoplasms. For information on accuracy of screening tests, we used the search terms sensitivity and specificity. We identified the most important studies from before 1994 from the Guide to Clinical Preventive Services, second edition, and from high-quality reviews. We used reference lists and expert recommendations to locate additional articles. Two reviewers independently reviewed a subset of 500 abstracts. Once consistency was established, the remainder were reviewed by one reviewer. We included studies if they contained data on yield of screening, screening tests, risk factors, risk assessment, effectiveness of early detection, or cost effectiveness. We abstracted the following descriptive information from full-text published studies of screening and recorded it in an electronic database: type of screening study, study design, setting, population, patient recruitment, screening test description, examiner, advertising targeted at high-risk groups or not targeted, reported risk factors of participants, and procedure for referrals. We also abstracted the yield of screening data including probabilities and numbers

  15. High-Throughput Screening of a Luciferase Reporter of Gene Silencing on the Inactive X Chromosome.

    Science.gov (United States)

    Keegan, Alissa; Plath, Kathrin; Damoiseaux, Robert

    2018-01-01

    Assays of luciferase gene activity are a sensitive and quantitative reporter system suited to high-throughput screening. We adapted a luciferase assay to a screening strategy for identifying factors that reactivate epigenetically silenced genes. This epigenetic luciferase reporter is subject to endogenous gene silencing mechanisms on the inactive X chromosome (Xi) in primary mouse cells and thus captures the multilayered nature of chromatin silencing in development. Here, we describe the optimization of an Xi-linked luciferase reactivation assay in 384-well format and adaptation of the assay for high-throughput siRNA and chemical screening. Xi-luciferase reactivation screening has applications in stem cell biology and cancer therapy. We have used the approach described here to identify chromatin-modifying proteins and to identify drug combinations that enhance the gene reactivation activity of the DNA demethylating drug 5-aza-2'-deoxycytidine.

  16. Between Stage and Screen

    NARCIS (Netherlands)

    Tornqvist, Egil

    1996-01-01

    Ingmar Bergman is worldwide known as a film and stage director. Yet no-one has attempted to compare his stage and screen activities. In Between stage and screen Egil Tornqvist examines formal and thematical correspondences and differences between a number of Bergman's stage, screen, and radio

  17. Screening for sepsis in general hospitalized patients: a systematic review.

    Science.gov (United States)

    Alberto, L; Marshall, A P; Walker, R; Aitken, L M

    2017-08-01

    Sepsis is a condition widely observed outside critical care areas. To examine the application of sepsis screening tools for early recognition of sepsis in general hospitalized patients to: (i) identify the accuracy of these tools; (ii) determine the outcomes associated with their implementation; and (iii) describe the implementation process. A systematic review method was used. PubMed, CINAHL, Cochrane, Scopus, Web of Science, and Embase databases were systematically searched for primary articles, published from January 1990 to June 2016, that investigated screening tools or alert mechanisms for early identification of sepsis in adult general hospitalized patients. The review protocol was registered with PROSPERO (CRD42016042261). More than 8000 citations were screened for eligibility after duplicates had been removed. Six articles met the inclusion criteria testing two types of sepsis screening tools. Electronic tools can capture, recognize abnormal variables, and activate an alert in real time. However, accuracy of these tools was inconsistent across studies with only one demonstrating high specificity and sensitivity. Paper-based, nurse-led screening tools appear to be more sensitive in the identification of septic patients but were only studied in small samples and particular populations. The process of care measures appears to be enhanced; however, demonstrating improved outcomes is more challenging. Implementation details are rarely reported. Heterogeneity of studies prevented meta-analysis. Clinicians, researchers and health decision-makers should consider these findings and limitations when implementing screening tools, research or policy on sepsis recognition in general hospitalized patients. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Electrochemical characterization of screen-printed and conventional carbon paste electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Fanjul-Bolado, Pablo; Hernandez-Santos, David; Lamas-Ardisana, Pedro Jose [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, 33006 Oviedo, Asturias (Spain); Martin-Pernia, Alberto [Departamento de Ingenieria Electrica, Electronica de Computadores y Sistemas, Universidad de Oviedo, 33204 Gijon, Asturias (Spain); Costa-Garcia, Agustin [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, 33006 Oviedo, Asturias (Spain)], E-mail: costa@fq.uniovi.es

    2008-04-01

    This work compares the electroactivity of a conventional carbon paste electrode and non-pretreated commercially available screen-printed carbon electrodes (from Alderon Biosciences, University of Florence and DropSens) towards some benchmark redox couples like hexaammineruthenium (III), ferricyanide, p-aminophenol and hydroquinone. While cyclic voltammograms of Ru{sup 3+} did not show significative electron transfer reactivity differences between the electrodes tested, the other redox systems exhibited higher reversible behaviours on DropSens electrodes. Scanning electron microscopy and roughness analysis with a profilometer were applied to detect the surface morphology of the working electrodes. The roughness evaluated of the screen-printed carbon working electrodes increased in this order Alderon < University of Florence < DropSens. Finally, the most electrochemically active and rough unpretreated electrode (DropSens commercial screen-printed electrode) was used to study the electrochemical-chemical reaction mechanism of indigo carmine oxidation in 0.1 M sulphuric acid. This study showed that the adsorption of the oxidation product of indigo carmine is stabilized when it is adsorbed on the surface of the electrode.

  19. Electrochemical characterization of screen-printed and conventional carbon paste electrodes

    International Nuclear Information System (INIS)

    Fanjul-Bolado, Pablo; Hernandez-Santos, David; Lamas-Ardisana, Pedro Jose; Martin-Pernia, Alberto; Costa-Garcia, Agustin

    2008-01-01

    This work compares the electroactivity of a conventional carbon paste electrode and non-pretreated commercially available screen-printed carbon electrodes (from Alderon Biosciences, University of Florence and DropSens) towards some benchmark redox couples like hexaammineruthenium (III), ferricyanide, p-aminophenol and hydroquinone. While cyclic voltammograms of Ru 3+ did not show significative electron transfer reactivity differences between the electrodes tested, the other redox systems exhibited higher reversible behaviours on DropSens electrodes. Scanning electron microscopy and roughness analysis with a profilometer were applied to detect the surface morphology of the working electrodes. The roughness evaluated of the screen-printed carbon working electrodes increased in this order Alderon < University of Florence < DropSens. Finally, the most electrochemically active and rough unpretreated electrode (DropSens commercial screen-printed electrode) was used to study the electrochemical-chemical reaction mechanism of indigo carmine oxidation in 0.1 M sulphuric acid. This study showed that the adsorption of the oxidation product of indigo carmine is stabilized when it is adsorbed on the surface of the electrode

  20. Pooled-matrix protein interaction screens using Barcode Fusion Genetics.

    Science.gov (United States)

    Yachie, Nozomu; Petsalaki, Evangelia; Mellor, Joseph C; Weile, Jochen; Jacob, Yves; Verby, Marta; Ozturk, Sedide B; Li, Siyang; Cote, Atina G; Mosca, Roberto; Knapp, Jennifer J; Ko, Minjeong; Yu, Analyn; Gebbia, Marinella; Sahni, Nidhi; Yi, Song; Tyagi, Tanya; Sheykhkarimli, Dayag; Roth, Jonathan F; Wong, Cassandra; Musa, Louai; Snider, Jamie; Liu, Yi-Chun; Yu, Haiyuan; Braun, Pascal; Stagljar, Igor; Hao, Tong; Calderwood, Michael A; Pelletier, Laurence; Aloy, Patrick; Hill, David E; Vidal, Marc; Roth, Frederick P

    2016-04-22

    High-throughput binary protein interaction mapping is continuing to extend our understanding of cellular function and disease mechanisms. However, we remain one or two orders of magnitude away from a complete interaction map for humans and other major model organisms. Completion will require screening at substantially larger scales with many complementary assays, requiring further efficiency gains in proteome-scale interaction mapping. Here, we report Barcode Fusion Genetics-Yeast Two-Hybrid (BFG-Y2H), by which a full matrix of protein pairs can be screened in a single multiplexed strain pool. BFG-Y2H uses Cre recombination to fuse DNA barcodes from distinct plasmids, generating chimeric protein-pair barcodes that can be quantified via next-generation sequencing. We applied BFG-Y2H to four different matrices ranging in scale from ~25 K to 2.5 M protein pairs. The results show that BFG-Y2H increases the efficiency of protein matrix screening, with quality that is on par with state-of-the-art Y2H methods. © 2016 The Authors. Published under the terms of the CC BY 4.0 license.

  1. In-bead screening

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to screening of one-bead-one-compound (OBOC) combinatorial libraries which is useful for the discovery of compounds displaying molecular interactions with a biological or a physicochemical system, such as substrates and inhibitors of enzymes and the like. The invention...... provides a method for screening a library of compounds for their interaction with a physico- chemical or biological system and a corresponding kit for performing the method of screening a one-bead-one-compound library of compounds....

  2. Mammography for women in their 40s : to screen or not to screen

    International Nuclear Information System (INIS)

    Le Heron, J.

    1997-01-01

    In the United States there is currently a raging controversy as to whether women in their 40s should be screened for breast cancer, with responsible medical bodies each issuing divergent recommendations. With the imminent commencement of the national breast screening programme in New Zealand, it is relevant to briefly review what underlies these differences. The evicence from international studies is that breast cancer deaths on the population of women aged 50 to 69 can be reduced by about 30% by good mammography screening programes. However the evidence in not so unequivocal for the 40 to 49 age group. Breast cancer in younger women tends to be more virulent, growing faster, and killing faster, and detection of cancer in younger breasts is more difficult than in breasts of older women due to the presence of greater amounts of glandular tissue. Where does this leave breast screening in New Zealand? The nationwide breast screening programme will commence with asymmptomatic women aged 50-64 eligible for screening. Extension to women older than 64 will be considered again once the programme is in place and running well. The Ministry of Health has not recommended routine screening for women in their 40s, but will continue to monitor the latest information and if, sufficient new evidence becomes availabe, the screening guidelines will be reassessed. (author)

  3. Just-in-Time Compound Pooling Increases Primary Screening Capacity without Compromising Screening Quality.

    Science.gov (United States)

    Elkin, L L; Harden, D G; Saldanha, S; Ferguson, H; Cheney, D L; Pieniazek, S N; Maloney, D P; Zewinski, J; O'Connell, J; Banks, M

    2015-06-01

    Compound pooling, or multiplexing more than one compound per well during primary high-throughput screening (HTS), is a controversial approach with a long history of limited success. Many issues with this approach likely arise from long-term storage of library plates containing complex mixtures of compounds at high concentrations. Due to the historical difficulties with using multiplexed library plates, primary HTS often uses a one-compound-one-well approach. However, as compound collections grow, innovative strategies are required to increase the capacity of primary screening campaigns. Toward this goal, we have developed a novel compound pooling method that increases screening capacity without compromising data quality. This method circumvents issues related to the long-term storage of complex compound mixtures by using acoustic dispensing to enable "just-in-time" compound pooling directly in the assay well immediately prior to assay. Using this method, we can pool two compounds per well, effectively doubling the capacity of a primary screen. Here, we present data from pilot studies using just-in-time pooling, as well as data from a large >2-million-compound screen using this approach. These data suggest that, for many targets, this method can be used to vastly increase screening capacity without significant reduction in the ability to detect screening hits. © 2015 Society for Laboratory Automation and Screening.

  4. COLA with scale-dependent growth: applications to screened modified gravity models

    Energy Technology Data Exchange (ETDEWEB)

    Winther, Hans A.; Koyama, Kazuya; Wright, Bill S. [Institute of Cosmology and Gravitation, University of Portsmouth, Dennis Sciama Building, Burnaby Road, Portsmouth, PO1 3FX (United Kingdom); Manera, Marc [Centre for Theoretical Cosmology, Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Zhao, Gong-Bo, E-mail: hans.a.winther@gmail.com, E-mail: kazuya.koyama@port.ac.uk, E-mail: manera.work@gmail.com, E-mail: bill.wright@port.ac.uk, E-mail: gong-bo.Zhao@port.ac.uk [National Astronomy Observatories, Chinese Academy of Science, Beijing, 100012 (China)

    2017-08-01

    We present a general parallelized and easy-to-use code to perform numerical simulations of structure formation using the COLA (COmoving Lagrangian Acceleration) method for cosmological models that exhibit scale-dependent growth at the level of first and second order Lagrangian perturbation theory. For modified gravity theories we also include screening using a fast approximate method that covers all the main examples of screening mechanisms in the literature. We test the code by comparing it to full simulations of two popular modified gravity models, namely f ( R ) gravity and nDGP, and find good agreement in the modified gravity boost-factors relative to ΛCDM even when using a fairly small number of COLA time steps.

  5. Photon attenuation by intensifying screens

    International Nuclear Information System (INIS)

    Holje, G.

    1983-01-01

    The photon attenuation by intensifying screens of different chemical composition has been determined. The attenuation of photons between 20 keV and 120 keV was measured by use of a multi-channel analyzer and a broad bremsstrahlung distribution. The attenuation by the intensifying screens was hereby determined simultaneously at many different monoenergetic photon energies. Experimentally determined attenuations were found to agree well with attenuation calculated from mass attenuation coefficients. The attenuation by the screens was also determined at various bremsstrahlung distributions, simulating those occurring behind the patient in various diagnostic X-ray examinations. The high attenuation in some of the intensifying screens form the basis for an analysis of the construction of asymmetric screen pairs. Single screen systems are suggested as a favourable alternative to thick screen pair systems. (Author)

  6. Characteristics and screening outcome of women referred twice at screening mammography

    International Nuclear Information System (INIS)

    Setz-Pels, Wikke; Duijm, Lucien E.M.; Jansen, Frits H.; Louwman, Marieke W.J.; Roumen, Rudi M.H.; Voogd, Adri C.

    2012-01-01

    To determine the characteristics and screening outcome of women referred twice at screening mammography. We included 424,703 consecutive screening mammograms and collected imaging, biopsy and surgery reports of women with screen-detected breast cancer. Review of screening mammograms was performed to determine whether or not an initial and second referral comprised the same lesion. The overall positive predictive value of referral for cancer was 38.6% (95% CI 37.3-39.8%). Of 147 (2.6%) women referred twice, 86 had been referred for a different lesion at second referral and 32 of these proved malignant (37.2%, 95% CI 27.0-47.4%). Sixty-one women had been referred twice for the same lesion, of which 22 proved malignant (36.1%, 95% CI 24.1-48.0%). Characteristics of these women were comparable to women with cancer diagnosed after first referral. Compared with women without cancer at second referral for the same lesion, women with cancer more frequently showed suspicious densities at screening mammography (86.4% vs 53.8%, P = 0.02) and work-up at first referral had less frequently included biopsy (22.7% vs 61.5%, P = 0.004). Cancer risk in women referred twice for the same lesion is similar to that observed in women referred once, or referred for a second time but for a different lesion. (orig.)

  7. Cervical Cancer Screening

    Science.gov (United States)

    ... Cancer found early may be easier to treat. Cervical cancer screening is usually part of a woman's health ... may do more tests, such as a biopsy. Cervical cancer screening has risks. The results can sometimes be ...

  8. Screening sensitivity theory

    International Nuclear Information System (INIS)

    Oblow, E.M.; Perey, F.G.

    1984-01-01

    A comprehensive rigorous theory is developed for screening sensitivity coefficients in largescale modeling applications. The theory uses Bayesian inference and group theory to establish a probabilistic framework for solving an underdetermined system of linear equations. The underdetermined problem is directly related to statistical screening sensitivity theory as developed in recent years. Several examples of the new approach to screening are worked out in detail and comparisons are made with statistical approaches to the problem. The drawbacks of these latter methods are discussed at some length

  9. Fragment-based screening in tandem with phenotypic screening provides novel antiparasitic hits.

    Science.gov (United States)

    Blaazer, Antoni R; Orrling, Kristina M; Shanmugham, Anitha; Jansen, Chimed; Maes, Louis; Edink, Ewald; Sterk, Geert Jan; Siderius, Marco; England, Paul; Bailey, David; de Esch, Iwan J P; Leurs, Rob

    2015-01-01

    Methods to discover biologically active small molecules include target-based and phenotypic screening approaches. One of the main difficulties in drug discovery is elucidating and exploiting the relationship between drug activity at the protein target and disease modification, a phenotypic endpoint. Fragment-based drug discovery is a target-based approach that typically involves the screening of a relatively small number of fragment-like (molecular weight <300) molecules that efficiently cover chemical space. Here, we report a fragment screening on TbrPDEB1, an essential cyclic nucleotide phosphodiesterase (PDE) from Trypanosoma brucei, and human PDE4D, an off-target, in a workflow in which fragment hits and a series of close analogs are subsequently screened for antiparasitic activity in a phenotypic panel. The phenotypic panel contained T. brucei, Trypanosoma cruzi, Leishmania infantum, and Plasmodium falciparum, the causative agents of human African trypanosomiasis (sleeping sickness), Chagas disease, leishmaniasis, and malaria, respectively, as well as MRC-5 human lung cells. This hybrid screening workflow has resulted in the discovery of various benzhydryl ethers with antiprotozoal activity and low toxicity, representing interesting starting points for further antiparasitic optimization. © 2014 Society for Laboratory Automation and Screening.

  10. Hierarchical screening for multiple mental disorders.

    Science.gov (United States)

    Batterham, Philip J; Calear, Alison L; Sunderland, Matthew; Carragher, Natacha; Christensen, Helen; Mackinnon, Andrew J

    2013-10-01

    There is a need for brief, accurate screening when assessing multiple mental disorders. Two-stage hierarchical screening, consisting of brief pre-screening followed by a battery of disorder-specific scales for those who meet diagnostic criteria, may increase the efficiency of screening without sacrificing precision. This study tested whether more efficient screening could be gained using two-stage hierarchical screening than by administering multiple separate tests. Two Australian adult samples (N=1990) with high rates of psychopathology were recruited using Facebook advertising to examine four methods of hierarchical screening for four mental disorders: major depressive disorder, generalised anxiety disorder, panic disorder and social phobia. Using K6 scores to determine whether full screening was required did not increase screening efficiency. However, pre-screening based on two decision tree approaches or item gating led to considerable reductions in the mean number of items presented per disorder screened, with estimated item reductions of up to 54%. The sensitivity of these hierarchical methods approached 100% relative to the full screening battery. Further testing of the hierarchical screening approach based on clinical criteria and in other samples is warranted. The results demonstrate that a two-phase hierarchical approach to screening multiple mental disorders leads to considerable increases efficiency gains without reducing accuracy. Screening programs should take advantage of prescreeners based on gating items or decision trees to reduce the burden on respondents. © 2013 Elsevier B.V. All rights reserved.

  11. 20 CFR 654.408 - Screening.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Screening. 654.408 Section 654.408 Employees... EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.408 Screening. (a) All outside openings shall be protected with screening of not less than 16 mesh. (b) All screen doors shall be...

  12. Neutron stars in screened modified gravity: Chameleon versus dilaton

    Science.gov (United States)

    Brax, Philippe; Davis, Anne-Christine; Jha, Rahul

    2017-04-01

    We consider the scalar field profile around relativistic compact objects such as neutron stars for a range of modified gravity models with screening mechanisms of the chameleon and Damour-Polyakov types. We focus primarily on inverse power law chameleons and the environmentally dependent dilaton as examples of both mechanisms. We discuss the modified Tolman-Oppenheimer-Volkoff equation and then implement a relaxation algorithm to solve for the scalar profiles numerically. We find that chameleons and dilatons behave in a similar manner and that there is a large degeneracy between the modified gravity parameters and the neutron star equation of state. This is exemplified by the modifications to the mass-radius relationship for a variety of model parameters.

  13. [Breast cancer screening in Austria: Key figures, age limits, screening intervals and evidence].

    Science.gov (United States)

    Jeitler, Klaus; Semlitsch, Thomas; Posch, Nicole; Siebenhofer, Andrea; Horvath, Karl

    2015-01-01

    In January 2014, the first nationwide quality-assured breast cancer screening program addressing women aged ≥ 40 years was introduced in Austria. As part of the process of developing a patient information leaflet, the Evidence Based Medicine (EBM) Review Center of the Medical University of Graz was charged with the task of assessing the potential benefits and harms of breast cancer screening from the available evidence. Based on these results, key figures were derived for mortality, false-positive and false-negative mammography results, and overdiagnosis, considering Austria-specific incidence rates for breast cancer and breast cancer mortality. Furthermore, the current evidence regarding age limits and screening interval, which were the subjects of controversial public discussions, was analyzed. A systematic search for primary and secondary literature was performed and additional evidence was screened, e. g., evaluation reports of European breast cancer screening programs. On the basis of the available evidence and of the Austrian breast cancer mortality and incidence rates, it can be assumed that - depending on the age group - 1 to 4 breast cancer deaths can be avoided per 1,000 women screened in a structured breast cancer screening program, while the overall mortality remains unchanged. On the other hand, 150 to 200 of these 1,000 women will be affected by false-positive results and 1 to 9 women by overdiagnosis due to the structured breast cancer screening. Therefore, the overall benefit-harm balance is uncertain. If women from 40 to 44 or above 70 years of age are considered, who can also participate in the Austrian screening program, even a negative benefit-harm balance seems possible. However, with the implementation of quality standards in breast cancer screening and the dissemination of a patient information leaflet, an improvement in the medical treatment situation, specifically in terms of informed decision-making, can be expected. Copyright © 2015

  14. Depression screening among older adults attending low-vision rehabilitation and eye-care services: Characteristics of those who screen positive and client acceptability of screening.

    Science.gov (United States)

    Holloway, Edith E; Sturrock, Bonnie A; Lamoureux, Ecosse L; Keeffe, Jill E; Rees, Gwyneth

    2015-12-01

    To investigate characteristics associated with screening positive for depressive symptoms among older adults accessing low-vision rehabilitation and eye-care services and to determine client acceptability of depression screening using the Patient Health Questionnaire-2 (PHQ-2) in these settings. One-hundred and twenty-four older adults (mean = 77.02 years, SD = 9.12) attending low-vision rehabilitation and eye-care services across Australia were screened for depression and invited to complete a telephone-administered questionnaire to determine characteristics associated with depressive symptoms and client acceptability of screening in these settings. Thirty-seven per cent (n = 46/124) of participants screened positive for depressive symptoms, and the majority considered the new depression screening method to be a 'good idea' in vision services (85%). Severe vision loss (<6/60 in the better eye) was associated with an increased odds of screening positive for depressive symptoms (odds ratio 2.37; 95% confidence interval 1.08-6.70) even after adjusting for potential confounders. Participants who screened positive had a preference for 'talking' therapy or a combination of medication and 'talking therapy' delivered within their own home (73%) or via telephone (67%). The PHQ-2 appears to be an acceptable method for depression screening in eye-care settings among older adults. Targeted interventions that incorporate home-based or telephone delivered therapy sessions may improve outcomes for depression in this group. © 2014 ACOTA.

  15. [Overdiagnosis in cancer screening].

    Science.gov (United States)

    Cervera Deval, J; Sentís Crivillé, M; Zulueta, J J

    2015-01-01

    In screening programs, overdiagnosis is defined as the detection of a disease that would have gone undetected without screening when that disease would not have resulted in morbimortality and was treated unnecessarily. Overdiagnosis is a bias inherent in screening and an undesired effect of secondary prevention and improved sensitivity of diagnostic techniques. It is difficult to discriminate a priori between clinically relevant diagnoses and those in which treatment is unnecessary. To minimize the effects of overdiagnosis, screening should be done in patients at risk. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  16. Screening for colorectal cancer

    DEFF Research Database (Denmark)

    Nielsen, Hans J.; Jakobsen, Karen V.; Christensen, Ib J.

    2011-01-01

    Emerging results indicate that screening improves survival of patients with colorectal cancer. Therefore, screening programs are already implemented or are being considered for implementation in Asia, Europe and North America. At present, a great variety of screening methods are available including...... into improvements of screening for colorectal cancer includes blood-based biological markers, such as proteins, DNA and RNA in combination with various demographically and clinically parameters into a "risk assessment evaluation" (RAE) test. It is assumed that such a test may lead to higher acceptance among...... procedures for colorectal cancer. Therefore, results of present research, validating RAE tests, are awaited with interest....

  17. Substance Abuse Screening

    Science.gov (United States)

    ... information is collected, stored or sent over the Internet. To ensure complete privacy, exit your web browser after completing this screening. ... information is collected, stored or sent over the Internet. To ensure complete privacy, exit your web browser after completing this screening. ...

  18. Beyond reverse pharmacology: Mechanism-based screening of Ayurvedic drugs.

    Science.gov (United States)

    Lele, R D

    2010-10-01

    This paper reviews the pharmacology of Indian medicinal plants, starting with the historical background of European work on the subject beginning as early as the 17th century, and tracing its history through the work of Sen and Bose in the 1930's, and Vakhil's historic 1949 paper on Sarpaghanda. The often crucial role of patient feedback in early discoveries is highlighted, as is the time lag between proof of pharmacological action and identification of the active principle, and subsequent elucidation of mechanism of action. In the case of Indian plants in the 20th century this process sometimes took almost 50 years. Reserpine and its mechanisms are given in detail, and its current relevance to public health discussed. The foundation of present day methods of pharmacology is briefly presented so the complexity of methods used to identify properties of Ayurveda derived drugs like forskolin and baicalein, and their bioavailability, may be better appreciated. Ayurveda derived anti-oxidants and their levels of action, immuno-modulators, particularly with respect to the NF-kB pathway and its implications for cancer control, are all considered. The example of curcumin derived from turmeric is explained in more detail, because of its role in cancer prevention. Finally, the paper emphasizes the importance of Ayurveda's concepts of rasayana as a form of dietary chemo-prevention; the significance of ahar, diet, in Ayurveda's aspiration to prevent disease and restore health thus becomes clear. Understood in this light, Ayurveda may transcend pharmacology as a treatment paradigm.

  19. Beyond reverse pharmacology: Mechanism-based screening of Ayurvedic drugs

    Directory of Open Access Journals (Sweden)

    R D Lele

    2010-01-01

    Full Text Available This paper reviews the pharmacology of Indian medicinal plants, starting with the historical background of European work on the subject beginning as early as the 17th century, and tracing its history through the work of Sen and Bose in the 1930′s, and Vakhil′s historic 1949 paper on Sarpaghanda. The often crucial role of patient feedback in early discoveries is highlighted, as is the time lag between proof of pharmacological action and identification of the active principle, and subsequent elucidation of mechanism of action. In the case of Indian plants in the 20th century this process sometimes took almost 50 years. Reserpine and its mechanisms are given in detail, and its current relevance to public health discussed. The foundation of present day methods of pharmacology is briefly presented so the complexity of methods used to identify properties of Ayurveda derived drugs like forskolin and baicalein, and their bioavailability, may be better appreciated. Ayurveda derived anti-oxidants and their levels of action, immuno-modulators, particularly with respect to the NF-kB pathway and its implications for cancer control, are all considered. The example of curcumin derived from turmeric is explained in more detail, because of its role in cancer prevention. Finally, the paper emphasizes the importance of Ayurveda′s concepts of rasayana as a form of dietary chemo-prevention; the significance of ahar, diet, in Ayurveda′s aspiration to prevent disease and restore health thus becomes clear. Understood in this light, Ayurveda may transcend pharmacology as a treatment paradigm.

  20. Measuring background by the DIN-1M spectrometer using the oscillating absorbing screen method

    International Nuclear Information System (INIS)

    Glazkov, Yu.Yu.; Liforov, V.G.; Novikov, A.G.; Parfenov, V.A.; Semenov, V.A.

    1982-01-01

    Technique for measuring background by a double pulse slow neutron spectrometer is described. To measure the background on oscillating absorbing screen (OAS) periodically overlapping primary neutron beam at the input of a mechanical interrupter was used. During the overlapping monochromatic neutrons conditioned the effect are removed out of the beam and general background conditions are not practically applied. Screen oscillation permits to realize the condition of simultaneous measurement of effect and background neutrons. The optimal period of oscillations amounts to approximately 3 min. Analysis of neutron spectra scattered with different materials and corresponding background curves measured by means of the OAS technique shows that the share of monochromatic neutrons passing through the screen constitutes less than 1% of elastic peak and relative decrease of the total background level doesn't exceed 1.5-2%

  1. WE-D-207-03: CT Protocols for Screening and the ACR Designated Lung Screening Program

    International Nuclear Information System (INIS)

    McNitt-Gray, M.

    2015-01-01

    In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in

  2. Screen or not to screen for peripheral arterial disease: guidance from a decision model.

    Science.gov (United States)

    Vaidya, Anil; Joore, Manuela A; Ten Cate-Hoek, Arina J; Ten Cate, Hugo; Severens, Johan L

    2014-01-29

    Asymptomatic Peripheral Arterial Disease (PAD) is associated with greater risk of acute cardiovascular events. This study aims to determine the cost-effectiveness of one time only PAD screening using Ankle Brachial Index (ABI) test and subsequent anti platelet preventive treatment (low dose aspirin or clopidogrel) in individuals at high risk for acute cardiovascular events compared to no screening and no treatment using decision analytic modelling. A probabilistic Markov model was developed to evaluate the life time cost-effectiveness of the strategy of selective PAD screening and consequent preventive treatment compared to no screening and no preventive treatment. The analysis was conducted from the Dutch societal perspective and to address decision uncertainty, probabilistic sensitivity analysis was performed. Results were based on average values of 1000 Monte Carlo simulations and using discount rates of 1.5% and 4% for effects and costs respectively. One way sensitivity analyses were performed to identify the two most influential model parameters affecting model outputs. Then, a two way sensitivity analysis was conducted for combinations of values tested for these two most influential parameters. For the PAD screening strategy, life years and quality adjusted life years gained were 21.79 and 15.66 respectively at a lifetime cost of 26,548 Euros. Compared to no screening and treatment (20.69 life years, 15.58 Quality Adjusted Life Years, 28,052 Euros), these results indicate that PAD screening and treatment is a dominant strategy. The cost effectiveness acceptability curves show 88% probability of PAD screening being cost effective at the Willingness To Pay (WTP) threshold of 40000 Euros. In a scenario analysis using clopidogrel as an alternative anti-platelet drug, PAD screening strategy remained dominant. This decision analysis suggests that targeted ABI screening and consequent secondary prevention of cardiovascular events using low dose aspirin or

  3. Reverse screening methods to search for the protein targets of chemopreventive compounds

    Science.gov (United States)

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-05-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and

  4. Comparison of first-tier cell-free DNA screening for common aneuploidies with conventional publically funded screening.

    Science.gov (United States)

    Langlois, Sylvie; Johnson, JoAnn; Audibert, François; Gekas, Jean; Forest, Jean-Claude; Caron, André; Harrington, Keli; Pastuck, Melanie; Meddour, Hasna; Tétu, Amélie; Little, Julian; Rousseau, François

    2017-12-01

    This study evaluates the impact of offering cell-free DNA (cfDNA) screening as a first-tier test for trisomies 21 and 18. This is a prospective study of pregnant women undergoing conventional prenatal screening who were offered cfDNA screening in the first trimester with clinical outcomes obtained on all pregnancies. A total of 1198 pregnant women were recruited. The detection rate of trisomy 21 with standard screening was 83% with a false positive rate (FPR) of 5.5% compared with 100% detection and 0% FPR for cfDNA screening. The FPR of cfDNA screening for trisomies 18 and 13 was 0.09% for each. Two percent of women underwent an invasive diagnostic procedure based on screening or ultrasound findings; without the cfDNA screening, it could have been as high as 6.8%. Amongst the 640 women with negative cfDNA results and a nuchal translucency (NT) ultrasound, only 3 had an NT greater or equal to 3.5 mm: one had a normal outcome and two lost their pregnancy before 20 weeks. cfDNA screening has the potential to be a highly effective first-tier screening approach leading to a significant reduction of invasive diagnostic procedures. For women with a negative cfDNA screening result, NT measurement has limited clinical utility. © 2017 John Wiley & Sons, Ltd.

  5. Modeling fiber motion in a pulp pressure screen: the effect of slot shape

    International Nuclear Information System (INIS)

    Dong, S.; Salcudean, M.; Gartshore, I.

    2003-01-01

    A pressure screen is a piece of equipment in the pulp and paper industry used either to remove contaminants from the pulp suspension or to separate fibers having different properties. Contaminants such as fiber bundles, bark and plastic specks are introduced when fibers are separated from the wood by mechanical or chemical pulping processes. Contaminants significantly affect the strength and smoothness of the paper and must be removed before the final paper is produced. The screen plate is a critical part of the pressure screen and its design is the key to screen performance. This paper uses a new and comprehensive CFD simulation tool to examine the flow and fiber behavior in a single slot screen having any reasonable slot shape. -This simulation tool includes three coupled models: first, the flow model solves the Reynolds Averaged Navier-Stokes (RANS) equation using the standard k - ε turbulence model to predict the flow field in the equipment. Second, a three-dimensional flexible fiber model is used to track the fiber trajectory in the screen. Third, a very general wall model is used to deal with the case when a fiber touches the equipment wall. The simulated results show that the slot shape has a critical influence on fiber behavior and screen performance. Three general slot shapes were investigated: the smooth slot, the step-step contour slot and slope-slope contour slot. Of these the slope-slope contour slot provides the best passage for the fibers with a length of 1mm and 3mm. (author)

  6. Newborn hearing screening.

    Science.gov (United States)

    Stewart, D L; Pearlman, A

    1994-11-01

    Congenital deafness is a relatively common problem with an incidence of 1/300 to 1/1000. Most states have no mass screening program for hearing loss, but the state of Kentucky compiles a High Risk Registry which is a historical survey of parents relating to risk factors for hearing loss. Unfortunately this survey can miss 50% of those who have a hearing deficit. If not detected prior to discharge, there is often a delay in diagnosis of deafness which prevents early intervention. We report 2 years' experience at Kosair Children's Hospital where 1,987 infants admitted to well baby, intermediate, or intensive care nurseries were screened using the ALGO-1 screener (Natus Medical Inc, Foster City, CA) which is a modified auditory brain stem evoked response (ABR). Our screening of this population led to an 11% incidence of referral for complete audiological evaluation. There were no significant complications. Forty-eight infants were found to have nonspecified, sensorineural, or conductive hearing loss. The positive predictive value of the test was 96%. Therefore, we feel that the use of the modified ABR in the newborn is a timely, cost efficient method of screening for hearing loss and should be used for mass screening of all newborns.

  7. A fast, simple method for screening radiation susceptibility genes by RNA interference

    International Nuclear Information System (INIS)

    Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Otsuki, Marika; Miyagishi, Makoto; Taira, Kazunari; Imai, Takashi; Harada, Yoshi-nobu

    2005-01-01

    Radiotherapy can cause unacceptable levels of damage to normal tissues in some cancer patients. To understand the molecular mechanisms underlying radiation-induced physiological responses, and to be able to predict the radiation susceptibility of normal tissues in individual patients, it is important to identify a comprehensive set of genes responsible for radiation susceptibility. We have developed a simple and rapid 96-well screening protocol using cell proliferation assays and RNA interference to identify genes associated with radiation susceptibility. We evaluated the performance of alamarBlue-, BrdU-, and sulforhodamine B-based cell proliferation assays using the 96-well format. Each proliferation assay detected the known radiation susceptibility gene, PRKDC. In a trial screen using 28 shRNA vectors, another known gene, CDKN1A, and one new radiation susceptibility gene, ATP5G3, were identified. Our results indicate that this method may be useful for large-scale screens designed to identify novel radiation susceptibility genes

  8. Pathway-selective sensitization of Mycobacterium tuberculosis for target-based whole-cell screening

    Science.gov (United States)

    Abrahams, Garth L.; Kumar, Anuradha; Savvi, Suzana; Hung, Alvin W.; Wen, Shijun; Abell, Chris; Barry, Clifton E.; Sherman, David R.; Boshoff, Helena I.M.; Mizrahi, Valerie

    2012-01-01

    SUMMARY Whole-cell screening of Mycobacterium tuberculosis (Mtb) remains a mainstay of drug discovery but subsequent target elucidation often proves difficult. Conditional mutants that under-express essential genes have been used to identify compounds with known mechanism of action by target-based whole-cell screening (TB-WCS). Here, the feasibility of TB-WCS in Mtb was assessed by generating mutants that conditionally express pantothenate synthetase (panC), diaminopimelate decarboxylase (lysA) and isocitrate lyase (icl1). The essentiality of panC and lysA, and conditional essentiality of icl1 for growth on fatty acids, was confirmed. Depletion of PanC and Icl1 rendered the mutants hypersensitive to target-specific inhibitors. Stable reporter strains were generated for use in high-throughput screening, and their utility demonstrated by identifying compounds that display greater potency against a PanC-depleted strain. These findings illustrate the power of TB-WCS as a tool for tuberculosis drug discovery. PMID:22840772

  9. Enhanced piezoelectric operation of NiO/GaN heterojunction generator by suppressed internal carrier screening

    International Nuclear Information System (INIS)

    Jeong, Dae Kyung; Kang, Jin-Ho; Ryu, Sang-Wan; Ha, Jun-Seok

    2017-01-01

    A NiO/GaN heterojunction piezoelectric generator was fabricated, and the improvement in device performance was analyzed. The electrical properties of NiO were varied by regulating the gas environment during sputtering. An optimized NiO layer was adopted for high piezoelectric voltage generation. Internal carrier screening was revealed to be the dominant mechanism degrading the piezoelectric performance, necessitating the suppression of carrier screening. The highly resistive NiO layer was advantageous in the suppression of carrier transport across the junction that screened the piezoelectric field. The maximum piezoelectric voltage and current density values obtained were 7.55 V and 1.14 µ A cm −2 , respectively. The power obtained was sufficient to operate a light-emitting diode combined with a charging circuit. (paper)

  10. Screening for abdominalt aortaaneurisme

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Juul, Søren; Henneberg, E W

    1997-01-01

    In spite of increasing number of elective resections of abdominal aortic aneurysms (AAA) the mortality or ruptured AAA is increasing. The advantages of elective operations are obvious; the lethality is 2-6% while the lethality of ruptured AAA is 75-95%. However, AAA seldom causes symptoms before...... rupture. Ultrasonographic screening for AAA takes 10 minutes per scan, and the sensitivity and specificity are high. Ultrasonographic screening for AAA is a reliable, safe and inexpensive method for screening, and screening for AAA is discussed worldwide. One point four percent of deaths among men from 65...... to 80 year of age are caused by ruptured AAA. Screening men over 65 for AAA can theoretically prevent a substantial number of deaths. Our calculations predict one prevented AAA-death per 200-300 scans for a cost of about 4000 DKK per saved year of life. However, cost-benefit analyses are based...

  11. Cost Analysis of Universal Screening vs. Risk Factor-Based Screening for Methicillin-Resistant Staphylococcus aureus (MRSA.

    Directory of Open Access Journals (Sweden)

    Virginia R Roth

    Full Text Available The literature remains conflicted regarding the most effective way to screen for MRSA. This study was designed to assess costs associated with universal versus risk factor-based screening for the reduction of nosocomial MRSA transmission.The study was conducted at The Ottawa Hospital, a large multi-centre tertiary care facility with approximately 47,000 admissions annually. From January 2006-December 2007, patients underwent risk factor-based screening for MRSA on admission. From January 2008 to August 2009 universal MRSA screening was implemented. A comparison of costs incurred during risk factor-based screening and universal screening was conducted. The model incorporated probabilities relating to the likelihood of being tested and the results of polymerase chain reaction (PCR testing with associated effects in terms of MRSA bacteremia and true positive and negative test results. Inputted costs included laboratory testing, contact precautions and infection control, private room costs, housekeeping, and length of hospital stay. Deterministic sensitivity analyses were conducted.The risk factor-based MRSA screening program screened approximately 30% of admitted patients and cost the hospital over $780 000 annually. The universal screening program screened approximately 83% of admitted patients and cost over $1.94 million dollars, representing an excess cost of $1.16 million per year. The estimated additional cost per patient screened was $17.76.This analysis demonstrated that a universal MRSA screening program was costly from a hospital perspective and was previously known to not be clinically effective at reducing MRSA transmission. These results may be useful to inform future model-based economic analyses of MRSA interventions.

  12. Obesity Prevention and Screening.

    Science.gov (United States)

    Mackey, Eleanor R; Olson, Alexandra; DiFazio, Marc; Cassidy, Omni

    2016-03-01

    Obesity is widespread, associated with several physical and psychosocial comorbidities, and is difficult to treat. Prevention of obesity across the lifespan is critical to improving the health of individuals and society. Screening and prevention efforts in primary care are an important step in addressing the obesity epidemic. Each period of human development is associated with unique risks, challenges, and opportunities for prevention and intervention. Screening tools for overweight/obesity, although imperfect, are quick and easy to administer. Screening should be conducted at every primary care visit and tracked longitudinally. Screening tools and cutoffs for overweight and obesity vary by age group. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Mammography screening in Denmark

    DEFF Research Database (Denmark)

    Vejborg, Ilse; Mikkelsen, Ellen Margrethe; Garne, Jens Peter

    2011-01-01

    Mammography screening is offered healthy women, and a high standard on professional and organizational level is mandatory not only in the screening programme but even in the diagnostic work-up and treatment. The main goal is to achieve a substantial reduction in disease specific mortality......, but it is not possible to evaluate the effect on mortality until several years later, and continuously monitoring of the quality of all aspects of a screening programme is necessary. Based on other European guidelines, 11 quality indicators have been defined, and guidelines concerning organizational requirements...... for a Danish screening programme as well as recommendations for the radiographic and radiological work have been drawn up....

  14. Mass screening in breast cancer

    International Nuclear Information System (INIS)

    Strax, P.

    1977-01-01

    Some questions about mass screening in breast cancer are answered it being concluded that: 1. mass screening for the detection of early breast cancer is the only means with proven potential for lowering the death rate of the disease; 2. mammography is an importante - if not the most important modality in mass screening; 3. new film - screen combinations generally available are capable of producing mammograms of excelent quality with radiation doses down to .1 rad into the body of breast. The risk of malignant changes from such dosage - even when given periodically is negligeable. New equipment, to be available, shortly, will use the new film - screen combinations in an automated manner with must reduce cost in time, filme, personnel and processing - of more than 50%. This would make mass screening more practical. (M.A.) [pt

  15. Current Cervical Carcinoma Screening Guidelines

    Directory of Open Access Journals (Sweden)

    Megan J. Schlichte

    2015-05-01

    Full Text Available A formidable threat to the health of women, cervical carcinoma can be prevented in many cases with adequate screening. The current guidelines for cervical carcinoma screening were created as joint recommendations of the American Cancer Society (ACS, the American Society for Colposcopy and Cervical Pathology (ASCCP and the American Society for Clinical Pathology (ASCP in 2012, and later accepted and promoted by the American Congress of Obstetricians and Gynecologists (ACOG. The 2012 recommendations underscore the utility of molecular testing as an adjunct to cytology screening for certain women and provide guidance to clinicians based on different risk-benefit considerations for different ages. This manuscript will review screening techniques and current recommendations for cervical cancer screening and human papilloma virus (HPV testing, as well as possible future screening strategies.

  16. [Comparison of screening performance between primary high-risk HPV screening and high-risk HPV screening plus liquid-based cytology cotesting in diagnosis of cervical precancerous or cancerous lesions].

    Science.gov (United States)

    Zhao, X L; Remila, Rezhake; Hu, S Y; Zhang, L; Xu, X Q; Chen, F; Pan, Q J; Zhang, X; Zhao, F H

    2018-05-06

    Objective: To evaluate and compare the screening performance of primary high-risk HPV(HR-HPV) screening and HR-HPV screening plus liquid-based cytology (LBC) cotesting in diagnosis of cervical cancer and precancerous lesions (CIN2+). Methods: We pooled 17 population-based cross-sectional studies which were conducted across China from 1999 to 2008. After obtaining informed consent, all women received liquid-based cytology(LBC)testing, HR-HPV DNA testing. Totally 28 777 women with complete LBC, HPV and biopsy results were included in the final analysis. Screening performance of primary HR-HPV DNA screening and HPV screening plus LBC co-testing in diagnosis of CIN2+ were calculated and compared among different age groups. Results: Among the whole population, the detection rates of primary HR-HPV screening and HR-HPV screening plus LBC co-testing are 3.05% (879 CIN2+) and 3.13%(900 CIN2+), respectively. The sensitivity were 96.4% and 98.7% (χ(2)=19.00, PHPV screening performed better than co-testing (AUC were 0.913 and 0.888; Z= 6.16, PHPV screening, co-testing showed significantly higher colposcopy referral rates (16.5% and 23.6%, respectively, χ(2)=132.00, PHPV screening in diagnosis of CIN2+, and was 12.5 (15.7%(288 cases) vs 1.3%(23 cases)) times as much as the detection rate of HR-HPV screening plus cytology contesting. Conclusion: Compared with primary HR-HPV screening, HR-HPV screening plus cytology co-testing does not show better results in the screening performance for CIN2+ detection, and the cost-effectiveness is not good enough, especially in younger age group.

  17. Pathophysiology, risk factors, and screening methods for prediabetes in women with polycystic ovary syndrome.

    Science.gov (United States)

    Gourgari, Evgenia; Spanakis, Elias; Dobs, Adrian Sandra

    2016-01-01

    Polycystic ovary syndrome (PCOS) is a syndrome associated with insulin resistance (IR), obesity, infertility, and increased cardiometabolic risk. This is a descriptive review of several mechanisms that can explain the IR among women with PCOS, other risk factors for the development of diabetes, and the screening methods used for the detection of glucose intolerance in women with PCOS. Few mechanisms can explain IR in women with PCOS such as obesity, insulin receptor signaling defects, and inhibition of insulin-mediated glucose uptake in adipocytes. Women with PCOS have additional risk factors for the development of glucose intolerance such as family history of diabetes, use of oral contraceptives, anovulation, and age. The Androgen Society in 2007 and the Endocrine Society in 2013 recommended using oral glucose tolerance test as a screening tool for abnormal glucose tolerance in all women with PCOS. The approach to detection of glucose intolerance among women with PCOS varies among health care providers. Large prospective studies are still needed for the development of guidelines with strong evidence. When assessing risk of future diabetes in women with PCOS, it is important to take into account the method used for screening as well as other risk factors that these women might have.

  18. Clinically targeted screening for congenital CMV - potential for integration into the National Hearing Screening Programme.

    Science.gov (United States)

    Kadambari, S; Luck, S; Davis, A; Williams, Ej; Berrington, J; Griffiths, Pd; Sharland, M

    2013-10-01

    Screening for a condition should only be undertaken if certain strict criteria are met. Congenital CMV (cCMV) is a leading cause of sensorineuronal hearing loss (SNHL) and meets many of these criteria, but is not currently screened for in the UK. Ganciclovir reduces CMV-induced progressive SNHL if treatment is begun in the first month of life. The Newborn Hearing Screening Programme (NHSP) has been shown to identify SNHL at the earliest possible age. The potential of integrating screening for cCMV into the NHSP is discussed to consolidate the link between screening, early diagnosis and management. The early diagnosis and treatment of cCMV may prevent a small proportion of late SNHL. In the absence of any screening programme, we provide evidence that clinically targeted screening through the NHSP is a potential option in the UK, enhancing the diagnostic pathway and enabling appropriate early treatment to reduce long-term morbidity. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  19. A fully automated primary screening system for the discovery of therapeutic antibodies directly from B cells.

    Science.gov (United States)

    Tickle, Simon; Howells, Louise; O'Dowd, Victoria; Starkie, Dale; Whale, Kevin; Saunders, Mark; Lee, David; Lightwood, Daniel

    2015-04-01

    For a therapeutic antibody to succeed, it must meet a range of potency, stability, and specificity criteria. Many of these characteristics are conferred by the amino acid sequence of the heavy and light chain variable regions and, for this reason, can be screened for during antibody selection. However, it is important to consider that antibodies satisfying all these criteria may be of low frequency in an immunized animal; for this reason, it is essential to have a mechanism that allows for efficient sampling of the immune repertoire. UCB's core antibody discovery platform combines high-throughput B cell culture screening and the identification and isolation of single, antigen-specific IgG-secreting B cells through a proprietary technique called the "fluorescent foci" method. Using state-of-the-art automation to facilitate primary screening, extremely efficient interrogation of the natural antibody repertoire is made possible; more than 1 billion immune B cells can now be screened to provide a useful starting point from which to identify the rare therapeutic antibody. This article will describe the design, construction, and commissioning of a bespoke automated screening platform and two examples of how it was used to screen for antibodies against two targets. © 2014 Society for Laboratory Automation and Screening.

  20. Empirical study of supervised gene screening

    Directory of Open Access Journals (Sweden)

    Ma Shuangge

    2006-12-01

    Full Text Available Abstract Background Microarray studies provide a way of linking variations of phenotypes with their genetic causations. Constructing predictive models using high dimensional microarray measurements usually consists of three steps: (1 unsupervised gene screening; (2 supervised gene screening; and (3 statistical model building. Supervised gene screening based on marginal gene ranking is commonly used to reduce the number of genes in the model building. Various simple statistics, such as t-statistic or signal to noise ratio, have been used to rank genes in the supervised screening. Despite of its extensive usage, statistical study of supervised gene screening remains scarce. Our study is partly motivated by the differences in gene discovery results caused by using different supervised gene screening methods. Results We investigate concordance and reproducibility of supervised gene screening based on eight commonly used marginal statistics. Concordance is assessed by the relative fractions of overlaps between top ranked genes screened using different marginal statistics. We propose a Bootstrap Reproducibility Index, which measures reproducibility of individual genes under the supervised screening. Empirical studies are based on four public microarray data. We consider the cases where the top 20%, 40% and 60% genes are screened. Conclusion From a gene discovery point of view, the effect of supervised gene screening based on different marginal statistics cannot be ignored. Empirical studies show that (1 genes passed different supervised screenings may be considerably different; (2 concordance may vary, depending on the underlying data structure and percentage of selected genes; (3 evaluated with the Bootstrap Reproducibility Index, genes passed supervised screenings are only moderately reproducible; and (4 concordance cannot be improved by supervised screening based on reproducibility.

  1. Effects of screened Coulomb (Yukawa) and exponential-cosine-screened Coulomb potentials on photoionization of H and He+

    International Nuclear Information System (INIS)

    Lin, C.Y.; Ho, Y.K.

    2010-01-01

    The screening effects due to the exponential-cosine-screened Coulomb and screened Coulomb (Yukawa) potentials on photoionization processes are explored within the framework of complex coordinate rotation method. The energy levels of H and He + in both screened potentials shifted with various Debye screening lengths are presented. The photoionization cross sections illustrate the considerable screening effects on photoionization processes in low energy region. The shape resonances can be found near ionization thresholds for certain of Debye screening lengths. The relations between the appearance of resonances and the existence of quasi-bound states under shielding conditions are discussed. (authors)

  2. Performance evaluation of CPF shredder type mechanical crusher with simulated core fuel pin

    International Nuclear Information System (INIS)

    Nakahara, Masaumi; Sano, Yuichi; Aose, Shin-ichi

    2006-12-01

    In the advanced aqueous reprocessing system, powder fuel dissolution has been investigated, which is quite effective on the dissolution for highly concentrated solution. As one of the effective means that powder the irradiated MOX fuel, we have been developing shredder type mechanical crusher. This apparatus can automatically crush the sheared fuel pieces by twin-shaft disk blades, powder the crushed fragments by disk blades and screen blade, and recover the powdered fuel. The shredder type mechanical crusher was developed for using in a hot cell in Chemical Processing Facility, and the first crush experiment with this crusher was carried out at July 2004 using the simulated core fuel pin. This experiment showed that the crushed fragments could not be grinded efficiency because screen blade vibrated up and down during the operation. Additionally, the strength of screen blade block was insufficient to crush the sheared fuel pieces stably. Therefore, about 70% of fuel was recovered in maximum. Based on the results of the first experiment, screen blade was fixed up mainly and the second experiment was carried out with improved apparatus at September 2005. In this experiment, about 96% of fuel could be recovered in maximum because screen blade was stable during the operation. (J.P.N.)

  3. Mechanized toxicological serum tests in screening hospitalized patients.

    Science.gov (United States)

    Hallbach, J; Guder, W G

    1991-09-01

    provided by the EMIT tox test kits. As a consequence, decision limits for all three group tests in serum were lowered to near the detection limit: (table: see text) For quantitative tests the lower limits of quantification were: (table: see text) The working reagents were stable for at least 14 days at 4-8 degrees C. Calibration curves were stable over the expiration period of reconstituted original reagents (6-12 weeks), also when working reagents were prepared in aliquots from stored reconstituted reagents. Application of the newly adapted programme to serum samples of nearly two hundred patients showed it to be suitable for screening patients in which intoxication is suspected or needs to be excluded.

  4. Descriptive epidemiology of screen and non-screen sedentary time in adolescents: a cross sectional study

    Directory of Open Access Journals (Sweden)

    Ridley Kate

    2010-12-01

    Full Text Available Abstract Background Much attention has been paid to adolescents' screen time, however very few studies have examined non-screen sedentary time (NSST. This study aimed to (1 describe the magnitude and composition of screen sedentary time (SST and NSST in Australian adolescents, (2 describe the socio-demographic correlates of SST and NSST, and (3 determine whether screen time is an adequate surrogate for total sedentary behaviour in this population. Methods 2200 9-16 year old Australians provided detailed use of time data for four days. Non-screen sedentary time (NSST included time spent participating in activities expected to elicit Results Adolescents spent a mean (SD of 345 (105 minutes/day in NSST, which constituted 60% of total sedentary time. School activities contributed 42% of NSST, socialising 19%, self-care (mainly eating 16%, and passive transport 15%. Screen time and NSST showed opposite patterns in relation to key socio-demographic characteristics, including sex, age, weight status, household income, parental education and day type. Because screen time was negatively correlated with NSST (r = -0.58, and exhibited a moderate correlation (r = 0.53 with total sedentary time, screen time was only a moderately effective surrogate for total sedentary time. Conclusions To capture a complete picture of young people's sedentary time, studies should endeavour to measure both screen time and NSST.

  5. Positive predictive values by mammographic density and screening mode in the Norwegian Breast Cancer Screening Program.

    Science.gov (United States)

    Moshina, Nataliia; Ursin, Giske; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2016-01-01

    To investigate the probability of breast cancer among women recalled due to abnormal findings on the screening mammograms (PPV-1) and among women who underwent an invasive procedure (PPV-2) by mammographic density (MD), screening mode and age. We used information about 28,826 recall examinations from 26,951 subsequently screened women in the Norwegian Breast Cancer Screening Program, 1996-2010. The radiologists who performed the recall examinations subjectively classified MD on the mammograms into three categories: fatty (70%). Screening mode was defined as screen-film mammography (SFM) and full-field digital mammography (FFDM). We examined trends of PPVs by MD, screening mode and age. We used logistic regression to estimate odds ratio (OR) of screen-detected breast cancer associated with MD among women recalled, adjusting for screening mode and age. PPV-1 and PPV-2 decreased by increasing MD, regardless of screening mode (p for trend breasts. Among women recalled, the adjusted OR of breast cancer decreased with increasing MD. Compared with women with fatty breasts, the OR was 0.90 (95% CI: 0.84-0.96) for those with medium dense breasts and 0.85 (95% CI: 0.76-0.95) for those with dense breasts. PPVs decreased by increasing MD. Fewer women needed to be recalled or undergo an invasive procedure to detect one breast cancer among those with fatty versus dense breasts in the screening program in Norway, 1996-2010. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Screening physical health? Yes! But...: nurses' views on physical health screening in mental health care.

    Science.gov (United States)

    Happell, Brenda; Scott, David; Nankivell, Janette; Platania-Phung, Chris

    2013-08-01

    To explore nurses' views on the role of nurses in screening and monitoring for physical care of consumers with serious mental illness, at a regional mental health care service. People with serious mental illness experience heightened incidence of preventable and treatable physical illnesses such as cardiovascular disease and diabetes. Screening and monitoring are considered universal clinical safeguards. Nurses can potentially facilitate systematic screening, but their views on physical health care practices are rarely investigated. Qualitative exploratory study. Focus group interviews with 38 nurses of a regional mental health care service district of Australia. To facilitate discussion, participants were presented with a screening system, called the Health Improvement Profile (HIP), as an exemplar of screening of physical health risks by nurses. Inductive data analysis and theme development were guided by a thematic analysis framework. Nurses argued that treatable and preventable physical health problems were common. Four main themes were identified: screening - essential for good practice; the policy-practice gap; 'screening then what?' and, is HIP the answer? Screening and monitoring were considered crucial to proper diagnosis and treatment, however, were not performed systematically or consistently. Nurse readiness for an enhanced role in screening was shaped by: role and responsibility issues, legal liability concerns, funding and staff shortages. Participants were concerned that lack of follow up would limit effectiveness of these interventions. Screening was considered an important clinical step in effective diagnosis and treatment; however, identified barriers need to be addressed to ensure screening is part of a systemic approach to improve physical health of consumers with serious mental illness. Nurses have potential to influence improvement in physical health outcomes for consumers of mental health services. Such potential can only be realised if a

  7. Risks of Colorectal Cancer Screening

    Science.gov (United States)

    ... Genetics of Colorectal Cancer Colorectal Cancer Screening Research Colorectal Cancer Screening (PDQ®)–Patient Version What is screening? Go ... These are called diagnostic tests . General Information About Colorectal Cancer Key Points Colorectal cancer is a disease in ...

  8. Cervical cancer - screening and prevention

    Science.gov (United States)

    Cancer cervix - screening; HPV - cervical cancer screening; Dysplasia - cervical cancer screening; Cervical cancer - HPV vaccine ... Almost all cervical cancers are caused by HPV (human papilloma virus). HPV is a common virus that spreads through sexual contact. Certain ...

  9. Screening diagnostic program breast cancer

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Zhakova, I.I.; Budnikova, N.V.; Rukhlyadko, E.D.

    1995-01-01

    The authors propose their screening program for detection of breast cancer. It includes the entire complex of present-day screening diagnostic methods, starting from an original system for the formation of groups at risk of breast cancer and completed by the direct diagnostic model of detection of the condition, oriented at a differentiated approach to the use of mammographic techniques. The proposed organizational and methodologic screening measures are both economic and diagnostically effective, thus meeting the principal requirements to screening programs. Screening of 8541 risk-groups patients helped detect 867 nodular formations, 244 of which were cancer and 623 benign formations. 8 refs., 3 figs.,

  10. The comparative evaluation of film-screen combinations

    International Nuclear Information System (INIS)

    Choi, Gyung Ja; Choi, Syng Kyu

    1988-01-01

    This study was to compare the quality of image by different screen and film combinations. Using the sensitometer measured the speed and average gradient of blue sensitive films and orthochromatic films. The films was combined with rare earth screen LR, Lm, LF and conventional screen OM, OH, XOR, OKa and exposed the stepwedge to impulse 2, 3, 4, 6, 10, 15, 24, 38, 60 and measured the density. The following results were obtained: 1. The density of film and film-screen combinations showed significant difference, then in film-screen combinations was significantly different by the screens than films. 2. The speed of blue sensitive films was little different, the TMG of orthochromatic films producted high speed, and the AX films was high average gradient. 3. The relative speed of film-screen combinations showed significant difference, and was high in the OKa of the conventional screens and in the LR of the rare earth screens, especially that of LR screen in the combination with blue sensitive films was high. 4. The average gradient of film-screen combinations showed no significant difference, and was high in the OKa screen and LR/OG combination, and that of OKa/AX combination was highest. 5. The latitude of film-screen combinations showed significant difference by screens, and was high in the LM screen in combination with blue sensitive films and in the OM screen in combination with orthochromatic films. 6. The subject contrast of film-screen combinations showed significant difference by screen, and was high in the LR screen in combination with blue sensitive AX film and orthochromatic TMG film.

  11. Smoking cessation and lung cancer screening

    DEFF Research Database (Denmark)

    Pedersen, Jesper Johannes Holst; Tønnesen, Philip; Ashraf, Haseem

    2016-01-01

    Smoking behavior may have a substantial influence on the overall effect of lung cancer screening. Non-randomized studies of smoking behavior during screening have indicated that computer tomography (CT) screening induces smoking cessation. Randomized studies have further elaborated that this effect...... and decrease smoking relapse rate. Also low smoking dependency and high motivation to quit smoking at baseline predicted smoking abstinence in screening trials. Lung cancer screening therefore seems to be a teachable moment for smoking cessation. Targeted smoking cessation counselling should be an integrated...... part of future lung cancer screening trials....

  12. Newborn Screening for Severe Combined Immunodeficiency in 11 Screening Programs in the United States

    Science.gov (United States)

    Kwan, Antonia; Abraham, Roshini S.; Currier, Robert; Brower, Amy; Andruszewski, Karen; Abbott, Jordan K.; Baker, Mei; Ballow, Mark; Bartoshesky, Louis E.; Bonagura, Vincent R.; Bonilla, Francisco A.; Brokopp, Charles; Brooks, Edward; Caggana, Michele; Celestin, Jocelyn; Church, Joseph A.; Comeau, Anne Marie; Connelly, James A.; Cowan, Morton J.; Cunningham-Rundles, Charlotte; Dasu, Trivikram; Dave, Nina; De La Morena, Maria T.; Duffner, Ulrich; Fong, Chin-To; Forbes, Lisa; Freedenberg, Debra; Gelfand, Erwin W.; Hale, Jaime E.; Celine Hanson, I.; Hay, Beverly N.; Hu, Diana; Infante, Anthony; Johnson, Daisy; Kapoor, Neena; Kay, Denise M.; Kohn, Donald B.; Lee, Rachel; Lehman, Heather; Lin, Zhili; Lorey, Fred; Abdel-Mageed, Aly; Manning, Adrienne; McGhee, Sean; Moore, Theodore B.; Naides, Stanley J.; Notarangelo, Luigi D.; Orange, Jordan S.; Pai, Sung-Yun; Porteus, Matthew; Rodriguez, Ray; Romberg, Neil; Routes, John; Ruehle, Mary; Rubenstein, Arye; Saavedra-Matiz, Carlos A.; Scott, Ginger; Scott, Patricia M.; Secord, Elizabeth; Seroogy, Christine; Shearer, William T.; Siegel, Subhadra; Silvers, Stacy K.; Stiehm, E. Richard; Sugerman, Robert W.; Sullivan, John L.; Tanksley, Susan; Tierce, Millard L.; Verbsky, James; Vogel, Beth; Walker, Rosalyn; Walkovich, Kelly; Walter, Jolan E.; Wasserman, Richard L.; Watson, Michael S.; Weinberg, Geoffrey A.; Weiner, Leonard B.; Wood, Heather; Yates, Anne B.; Puck, Jennifer M.

    2015-01-01

    IMPORTANCE Newborn screening for severe combined immunodeficiency (SCID) using assays to detect T-cell receptor excision circles (TRECs) began in Wisconsin in 2008, and SCID was added to the national recommended uniform panel for newborn screened disorders in 2010. Currently 23 states, the District of Columbia, and the Navajo Nation conduct population-wide newborn screening for SCID. The incidence of SCID is estimated at 1 in 100 000 births. OBJECTIVES To present data from a spectrum of SCID newborn screening programs, establish population-based incidence for SCID and other conditions with T-cell lymphopenia, and document early institution of effective treatments. DESIGN Epidemiological and retrospective observational study. SETTING Representatives in states conducting SCID newborn screening were invited to submit their SCID screening algorithms, test performance data, and deidentified clinical and laboratory information regarding infants screened and cases with nonnormal results. Infants born from the start of each participating program from January 2008 through the most recent evaluable date prior to July 2013 were included. Representatives from 10 states plus the Navajo Area Indian Health Service contributed data from 3 030 083 newborns screened with a TREC test. MAIN OUTCOMES AND MEASURES Infants with SCID and other diagnoses of T-cell lymphopenia were classified. Incidence and, where possible, etiologies were determined. Interventions and survival were tracked. RESULTS Screening detected 52 cases of typical SCID, leaky SCID, and Omenn syndrome, affecting 1 in 58 000 infants (95%CI, 1/46 000-1/80 000). Survival of SCID-affected infants through their diagnosis and immune reconstitution was 87%(45/52), 92%(45/49) for infants who received transplantation, enzyme replacement, and/or gene therapy. Additional interventions for SCID and non-SCID T-cell lymphopenia included immunoglobulin infusions, preventive antibiotics, and avoidance of live vaccines. Variations in

  13. Lung cancer screening: Update

    International Nuclear Information System (INIS)

    Kim, Hyea Young

    2015-01-01

    Lung cancer is the leading cause of cancer deaths worldwide as well as in Korea. A recent National Lung Screening Trial in U.S. revealed that low-dose CT (LDCT) screening reduced lung cancer specific mortality by 20% in high risk individuals as compared to chest radiograph screening. Based on this evidence, several expert societies in U.S. and Korean multisociety collaborative committee developed guidelines for recommendation of lung cancer screening using annual LDCT in high risk populations. In most of the societies high risk groups are defined as persons aged 55 to 74 years, who are current smokers with history of smoking of more than 30 packs per year or ex-smokers, who quit smoking up to 15 or more years ago. The benefits of LDCT screening are modestly higher than the harms in high risk individuals. The harms included a high rate of false-positive findings, over-diagnosis and radiation-related deaths. Invasive diagnostic procedure due to false positive findings may lead to complications. LDCT should be performed in qualified hospitals and interpreted by expert radiologists. Recently, the American College of Radiology released the current version of Lung cancer CT screening Reporting and Data Systems. Education and actions to stop smoking must be offered to current smokers

  14. Lung cancer screening: Update

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyea Young [Dept. of Radiology, Center for Lung Cancer, National Cancer Center, Goyang (Korea, Republic of)

    2015-09-15

    Lung cancer is the leading cause of cancer deaths worldwide as well as in Korea. A recent National Lung Screening Trial in U.S. revealed that low-dose CT (LDCT) screening reduced lung cancer specific mortality by 20% in high risk individuals as compared to chest radiograph screening. Based on this evidence, several expert societies in U.S. and Korean multisociety collaborative committee developed guidelines for recommendation of lung cancer screening using annual LDCT in high risk populations. In most of the societies high risk groups are defined as persons aged 55 to 74 years, who are current smokers with history of smoking of more than 30 packs per year or ex-smokers, who quit smoking up to 15 or more years ago. The benefits of LDCT screening are modestly higher than the harms in high risk individuals. The harms included a high rate of false-positive findings, over-diagnosis and radiation-related deaths. Invasive diagnostic procedure due to false positive findings may lead to complications. LDCT should be performed in qualified hospitals and interpreted by expert radiologists. Recently, the American College of Radiology released the current version of Lung cancer CT screening Reporting and Data Systems. Education and actions to stop smoking must be offered to current smokers.

  15. Fast screening of ketamine in biological samples based on molecularly imprinted photonic hydrogels

    International Nuclear Information System (INIS)

    Meng, Liang; Meng, Pinjia; Zhang, Qingqing; Wang, Yanji

    2013-01-01

    Graphical abstract: A novel label-free colorimetric chemosensor: with the increase in the concentration of ketamine, the Bragg diffraction peak of MIPHs gradually shifted to the longer wavelength region. Accompanying the peak shift, the color change of MIPHs was also observed obviously: from green to red. Highlights: ► We developed the label-free colorimetric MIPHs for handy and fast screening of ketamine. ► The obvious color change of MIPHs was observed upon ketamine. ► The MIPHs exhibited good sensing abilities in an aqueous environment. ► The sensing mechanisms of the water-compatible MIPHs were investigated. ► The MIPHs were employed to screening ketamine in real biological samples. -- Abstract: A novel label-free colorimetric chemosensor was developed for handy and fast screening of ketamine with high sensitivity and specificity based on molecularly imprinted photonic hydrogels (MIPHs) that combined the colloidal-crystal with molecular imprinting technique. The unique inverse opal arrays with a thin polymer wall in which the imprinted nanocavities of ketamine moleculars distributed allowed high sensitive, quick responsive, specific detection of the target analyte, and good regenerating ability in an aqueous environment. Due to the hierarchical inverse opal structural characteristics, the specific ketamine molecular recognition process can induce obvious swelling of the MIPHs to be directly transferred into visually perceptible optical signal (change in color) which can be detected by the naked eye through Bragg diffractive shifts of ordered macroporous arrays. In order to enhance the recognition ability in aqueous environments, the MIPHs were designed as water-compatible and synthesized in a water–methanol system. The molecular recognition mechanisms were investigated. The proposed MIPHs were successfully employed to screen trace level ketamine in human urine and saliva samples, exhibiting high sensitivity, rapid response, and specificity in the

  16. Fast screening of ketamine in biological samples based on molecularly imprinted photonic hydrogels

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Liang [Department of Forensic Science, People' s Public Security University of China, Beijing (China); Meng, Pinjia, E-mail: mengpinjia@163.com [Department of Forensic Science, People' s Public Security University of China, Beijing (China); Zhang, Qingqing; Wang, Yanji [Department of Forensic Science, People' s Public Security University of China, Beijing (China)

    2013-04-10

    Graphical abstract: A novel label-free colorimetric chemosensor: with the increase in the concentration of ketamine, the Bragg diffraction peak of MIPHs gradually shifted to the longer wavelength region. Accompanying the peak shift, the color change of MIPHs was also observed obviously: from green to red. Highlights: ► We developed the label-free colorimetric MIPHs for handy and fast screening of ketamine. ► The obvious color change of MIPHs was observed upon ketamine. ► The MIPHs exhibited good sensing abilities in an aqueous environment. ► The sensing mechanisms of the water-compatible MIPHs were investigated. ► The MIPHs were employed to screening ketamine in real biological samples. -- Abstract: A novel label-free colorimetric chemosensor was developed for handy and fast screening of ketamine with high sensitivity and specificity based on molecularly imprinted photonic hydrogels (MIPHs) that combined the colloidal-crystal with molecular imprinting technique. The unique inverse opal arrays with a thin polymer wall in which the imprinted nanocavities of ketamine moleculars distributed allowed high sensitive, quick responsive, specific detection of the target analyte, and good regenerating ability in an aqueous environment. Due to the hierarchical inverse opal structural characteristics, the specific ketamine molecular recognition process can induce obvious swelling of the MIPHs to be directly transferred into visually perceptible optical signal (change in color) which can be detected by the naked eye through Bragg diffractive shifts of ordered macroporous arrays. In order to enhance the recognition ability in aqueous environments, the MIPHs were designed as water-compatible and synthesized in a water–methanol system. The molecular recognition mechanisms were investigated. The proposed MIPHs were successfully employed to screen trace level ketamine in human urine and saliva samples, exhibiting high sensitivity, rapid response, and specificity in the

  17. Measuring lip force by oral screens. Part 1: Importance of screen size and individual variability.

    Science.gov (United States)

    Wertsén, Madeleine; Stenberg, Manne

    2017-06-01

    To reduce drooling and facilitate food transport in rehabilitation of patients with oral motor dysfunction, lip force can be trained using an oral screen. Longitudinal studies evaluating the effect of training require objective methods. The aim of this study was to evaluate a method for measuring lip strength, to investigate normal values and fluctuation of lip force in healthy adults on 1 occasion and over time, to study how the size of the screen affects the force, to evaluate the most appropriate measure of reliability, and to identify force performed in relation to gender. Three different sizes of oral screens were used to measure the lip force for 24 healthy adults on 3 different occasions, during a period of 6 months, using an apparatus based on strain gauge. The maximum lip force as evaluated with this method depends on the area of the screen size. By calculating the projected area of the screen, the lip force could be normalized to an oral screen pressure quantity expressed in kPa, which can be used for comparing measurements from screens with different sizes. Both the mean value and standard deviation were shown to vary between individuals. The study showed no differences regarding gender and only small variation with age. Normal variation over time (months) may be up to 3 times greater than the standard error of measurement at a certain occasion. The lip force increases in relation to the projected area of the screen. No general standard deviation can be assigned to the method and all measurements should be analyzed individually based on oral screen pressure to compensate for different screen sizes.

  18. [Organized breast cancer screening].

    Science.gov (United States)

    Rouëssé, Jacques; Sancho-Garnier, Hélèn

    2014-02-01

    Breast screening programs are increasingly controversial, especially regarding two points: the number of breast cancer deaths they avoid, and the problem of over-diagnosis and over-treatment. The French national breast cancer screening program was extended to cover the whole country in 2004. Ten years later it is time to examine the risk/benefit ratio of this program and to discuss the need for change. Like all forms of cancer management, screening must be regularly updated, taking into account the state of the art, new evidence, and uncertainties. All screening providers should keep themselves informed of the latest findings. In the French program, women aged 50-74 with no major individual or familial risk factors for breast cancer are offered screening mammography and clinical breast examination every two years. Images considered non suspicious of malignancy by a first reader are re-examined by a second reader. The devices and procedures are subjected to quality controls. Participating radiologists (both public and private) are required to read at least 500 mammographies per year. The program's national participation rate was 52.7 % in 2012. When individual screening outside of the national program is taken into account (nearly 15 % of women), coverage appears close to the European recommendation of 65 %. Breast cancer mortality has been falling in France by 0.6 % per year for over 30 years, starting before mass screening was implemented, and by 1.5 % since 2005. This decline can be attributed in part to earlier diagnosis and better treatment, so that the specific impact of screening cannot easily be measured. Over-treatment, defined as the detection and treatment of low-malignancy tumors that would otherwise not have been detected in a person's lifetime, is a major negative effect of screening, but its frequency is not precisely known (reported to range from 1 % to 30 %). In view of these uncertainties, it would be advisable to modify the program in order to

  19. Factors Influencing Colorectal Cancer Screening Participation

    Directory of Open Access Journals (Sweden)

    Antonio Z. Gimeno García

    2012-01-01

    Full Text Available Colorectal cancer (CRC is a major health problem worldwide. Although population-based CRC screening is strongly recommended in average-risk population, compliance rates are still far from the desirable rates. High levels of screening uptake are necessary for the success of any screening program. Therefore, the investigation of factors influencing participation is crucial prior to design and launches a population-based organized screening campaign. Several studies have identified screening behaviour factors related to potential participants, providers, or health care system. These influencing factors can also be classified in non-modifiable (i.e., demographic factors, education, health insurance, or income and modifiable factors (i.e., knowledge about CRC and screening, patient and provider attitudes or structural barriers for screening. Modifiable determinants are of great interest as they are plausible targets for interventions. Interventions at different levels (patient, providers or health care system have been tested across the studies with different results. This paper analyzes factors related to CRC screening behaviour and potential interventions designed to improve screening uptake.

  20. Screening-induced surface polar optical phonon scattering in dual-gated graphene field effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Bo, E-mail: hubo2011@semi.ac.cn

    2015-03-15

    The effect of surface polar optical phonons (SOs) from the dielectric layers on electron mobility in dual-gated graphene field effect transistors (GFETs) is studied theoretically. By taking into account SO scattering of electron as a main scattering mechanism, the electron mobility is calculated by the iterative solution of Boltzmann transport equation. In treating scattering with the SO modes, the dynamic dielectric screening is included and compared to the static dielectric screening and the dielectric screening in the static limit. It is found that the dynamic dielectric screening effect plays an important role in the range of low net carrier density. More importantly, in-plane acoustic phonon scattering and charged impurity scattering are also included in the total mobility for SiO{sub 2}-supported GFETs with various high-κ top-gate dielectric layers considered. The calculated total mobility results suggest both Al{sub 2}O{sub 3} and AlN are the promising candidate dielectric layers for the enhancement in room temperature mobility of graphene in the future.

  1. Screening for autistic spectrum disorder in children aged 14-15 months. II: population screening with the Early Screening of Autistic Traits Questionnaire (ESAT). Design and general findings.

    NARCIS (Netherlands)

    Dietz, C.; Swinkels, S.H.N.; Daalen, E. van; Engeland, H.M. van; Buitelaar, J.K.

    2006-01-01

    A two-stage protocol for screening for autistic spectrum disorders (ASD) was evaluated in a random population of 31,724 children aged 14-15 months. Children were first pre-screened by physicians at well-baby clinics using a 4-item screening instrument. Infants that screened positive were then

  2. Lung cancer incidence and mortality in National Lung Screening Trial participants who underwent low-dose CT prevalence screening: a retrospective cohort analysis of a randomised, multicentre, diagnostic screening trial.

    Science.gov (United States)

    Patz, Edward F; Greco, Erin; Gatsonis, Constantine; Pinsky, Paul; Kramer, Barnett S; Aberle, Denise R

    2016-05-01

    Annual low-dose CT screening for lung cancer has been recommended for high-risk individuals, but the necessity of yearly low-dose CT in all eligible individuals is uncertain. This study examined rates of lung cancer in National Lung Screening Trial (NLST) participants who had a negative prevalence (initial) low-dose CT screen to explore whether less frequent screening could be justified in some lower-risk subpopulations. We did a retrospective cohort analysis of data from the NLST, a randomised, multicentre screening trial comparing three annual low-dose CT assessments with three annual chest radiographs for the early detection of lung cancer in high-risk, eligible individuals (aged 55-74 years with at least a 30 pack-year history of cigarette smoking, and, if a former smoker, had quit within the past 15 years), recruited from US medical centres between Aug 5, 2002, and April 26, 2004. Participants were followed up for up to 5 years after their last annual screen. For the purposes of this analysis, our cohort consisted of all NLST participants who had received a low-dose CT prevalence (T0) screen. We determined the frequency, stage, histology, study year of diagnosis, and incidence of lung cancer, as well as overall and lung cancer-specific mortality, and whether lung cancers were detected as a result of screening or within 1 year of a negative screen. We also estimated the effect on mortality if the first annual (T1) screen in participants with a negative T0 screen had not been done. The NLST is registered with ClinicalTrials.gov, number NCT00047385. Our cohort consisted of 26 231 participants assigned to the low-dose CT screening group who had undergone their T0 screen. The 19 066 participants with a negative T0 screen had a lower incidence of lung cancer than did all 26 231 T0-screened participants (371·88 [95% CI 337·97-408·26] per 100 000 person-years vs 661·23 [622·07-702·21]) and had lower lung cancer-related mortality (185·82 [95% CI 162·17

  3. New generation expandable sand screens

    OpenAIRE

    Syltøy, Christer

    2014-01-01

    Master's thesis in Petroleum engineering This thesis aims to give a general insight into sand control and various sorts of sand control measures and applications of sand control tools. Special focus will be given to expandable sand screens – a technology which came about in the late 1990’s through the use of flexible, expandable tubulars as base pipe in sand screens. More specifically Darcy’s Hydraulic Endurance Screens, a compliant sand screen system using hydraulic activation, and the fu...

  4. How is adults' screen time behaviour influencing their views on screen time restrictions for children? A cross-sectional study.

    Science.gov (United States)

    Schoeppe, Stephanie; Rebar, Amanda L; Short, Camille E; Alley, Stephanie; Van Lippevelde, Wendy; Vandelanotte, Corneel

    2016-03-01

    High screen time in children and its detrimental health effects is a major public health problem. How much screen time adults think is appropriate for children remains little explored, as well as whether adults' screen time behaviour would determine their views on screen time restrictions for children. This study aimed to investigate how adults' screen time behaviour influences their views on screen time restrictions for children, including differences by gender and parental status. In 2013, 2034 Australian adults participated in an online survey conducted by the Population Research Laboratory at Central Queensland University, Rockhampton. Adult screen time behaviour was assessed using the Workforce Sitting Questionnaire. Adults reported the maximum time children aged between 5-12 years should be allowed to spend watching TV and using a computer. Ordinal logistic regression was used to compare adult screen time behaviour with views on screen time restrictions for children. Most adults (68%) held the view that children should be allowed no more than 2 h of TV viewing and computer use on school days, whilst fewer adults (44%) thought this screen time limit is needed on weekend days. Women would impose higher screen time restrictions for children than men (p 2 h on watching TV and using the computer at home on work days (66%) and non-work days (88%). Adults spending ≤ 2 h/day in leisure-related screen time were less likely to permit children > 2 h/day of screen time. These associations did not differ by adult gender and parental status. Most adults think it is appropriate to limit children's screen time to the recommended ≤ 2 h/day but few adults themselves adhere to this screen time limit. Adults with lower screen use may be more inclined to limit children's screen time. Strategies to reduce screen time in children may also need to target adult screen use.

  5. More misinformation on breast cancer screening

    OpenAIRE

    Kopans, Daniel B.

    2017-01-01

    Unfortunately, a great deal of misinformation has accumulated in the breast cancer screening literature that is based on flawed analyses in an effort to reduce access to screening. Quite remarkably, much of this has come from publications in previously highly respected medical journals. In several papers the intervention (mammography screening) is faulted yet the analyses provided no data on who participated in mammography screening, and which cancers were detected by mammography screening. I...

  6. Cathode ray tube screens

    International Nuclear Information System (INIS)

    Cockayne, B.; Robbins, D.J.; Glasper, J.L.

    1982-01-01

    An improved cathode ray tube screen is described which consists of a single- or a poly-crystalline slice of a material such as yttrium aluminium garnet in which dopants such as Tb 3 + , Eu 3 + , Ce 3 + or Tm 3 + are ion implanted to different depths or in different areas of the screen. Annealing the screen removes lattice damage caused by the ion implanting and assists the diffusion of the dopant into the crystal. (U.K.)

  7. Screening for Cervical Cancer

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Cervical Cancer The U.S. Preventive Services Task Force (Task Force) has issued final recommendations on Screening for Cervical Cancer . These recommendations are for women ...

  8. A fluorescence-based rapid screening assay for cytotoxic compounds

    International Nuclear Information System (INIS)

    Montoya, Jessica; Varela-Ramirez, Armando; Estrada, Abril; Martinez, Luis E.; Garza, Kristine; Aguilera, Renato J.

    2004-01-01

    A simple fluorescence-based assay was developed for the rapid screening of potential cytotoxic compounds generated by combinatorial chemistry. The assay is based on detection of nuclear green fluorescent protein (GFP) staining of a human cervical cancer cell line (HeLa) carrying an integrated histone H2B-GFP fusion gene. Addition of a cytotoxic compound to the HeLa-GFP cells results in the eventual degradation of DNA and loss of the GFP nuclear fluorescence. Using this assay, we screened 11 distinct quinone derivatives and found that several of these compounds were cytotoxic. These compounds are structurally related to plumbagin an apoptosis-inducing naphthoquinone isolated from Black Walnut. In order to determine the mechanism by which cell death was induced, we performed additional experiments with the most cytotoxic quinones. These compounds were found to induce morphological changes (blebbing and nuclear condensation) consistent with induction of apoptosis. Additional tests revealed that the cytotoxic compounds induce both necrotic and apoptotic modes of death

  9. An effective HIV-1 integrase inhibitor screening platform: Rationality validation of drug screening, conformational mobility and molecular recognition analysis for PFV integrase complex with viral DNA.

    Science.gov (United States)

    Du, Wenyi; Zuo, Ke; Sun, Xin; Liu, Wei; Yan, Xiao; Liang, Li; Wan, Hua; Chen, Fengzheng; Hu, Jianping

    2017-11-01

    As an important target for the development of novel anti-AIDS drugs, HIV-1 integrase (IN) has been widely concerned. However, the lack of a complete accurate crystal structure of HIV-1 IN greatly blocks the discovery of novel inhibitors. In this work, an effective HIV-1 IN inhibitor screening platform, namely PFV IN, was filtered from all species of INs. Next, the 40.8% similarity with HIV-1 IN, as well as the high efficiency of virtual screening and the good agreement between calculated binding free energies and experimental ones all proved PFV IN is a promising screening platform for HIV-1 IN inhibitors. Then, the molecular recognition mechanism of PFV IN by its substrate viral DNA and six naphthyridine derivatives (NRDs) inhibitors was investigated through molecular docking, molecular dynamics simulations and water-mediated interactions analyses. The functional partition of NRDs IN inhibitors could be divided into hydrophobic and hydrophilic ones, and the Mg 2+ ions, water molecules and conserved DDE motif residues all interacted with the hydrophilic partition, while the bases in viral DNA and residues like Tyr212, Pro214 interacted with the hydrophobic one. Finally, the free energy landscape (FEL) and cluster analyses were performed to explore the molecular motion of PFV IN-DNA system. It is found that the association with NRDs inhibitors would obviously decrease the motion amplitude of PFV IN-DNA, which may be one of the most potential mechanisms of IN inhibitors. This work will provide a theoretical basis for the inhibitor design based on the structure of HIV-1 IN. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Completing the cervical screening pathway: Factors that facilitate the increase of self-collection uptake among under-screened and never-screened women, an Australian pilot study.

    Science.gov (United States)

    McLachlan, E; Anderson, S; Hawkes, D; Saville, M; Arabena, K

    2018-02-01

    To examine factors that enhance under-screened and never-screened women's completion of the self-collection alternative pathway of the Renewed National Cervical Screening Program (ncsp) in Victoria, Australia. With the Australian ncsp changing, starting on 1 December 2017, the Medical Services Advisory Committee (msac) recommended implementing human papillomavirus (hpv) testing using a self-collected sample for under-screened and never-screened populations. In response, a multi-agency group implemented an hpv self-collection pilot project to trial self-collection screening pathways for eligible women. Quantitative data were collected on participation rates and compliance rates with follow-up procedures across three primary health care settings. Forty women who self-collected were interviewed in a semi-structured format, and seven agency staff completed in-depth interviews. Qualitative data were used to identify and understand clinical and personal enablers that assisted women to complete self-collection cervical screening pathways successfully. Eighty-five per cent (10 women) of participants who tested positive for hpv successfully received their results and completed follow-up procedures as required. Two remaining participants also received hpv-positive results. However, agencies were unable to engage them in follow-up services and procedures. The overall participation rate in screening (self-collection or Pap test) was 85.7% (84 women), with 79 women self-collecting. Qualitative data indicated that clear explanations on self-collection, development of trusting, empathetic relationships with health professionals, and recognition of participants' past experiences were critical to the successful completion of the self-collection pathway. When asked about possible inhibitors to screening and to following up on results and appointments, women cited poor physical and mental health, as well as financial and other structural barriers. A well-implemented process, led by

  11. Breast cancer screening implementation and reassurance

    DEFF Research Database (Denmark)

    Østerø, J; Siersma, Volkert Dirk; Brodersen, John

    2013-01-01

    difference in reported psychosocial aspects had disappeared or been reduced because of the nationwide screening implementation. METHODS: The 1000 women included in the previous survey were posted part I of the questionnaire Consequences of Screening in Breast Cancer (COS-BC1) in August 2011, nearly 5 years......BACKGROUND: Women not offered screening mammography reported higher levels of negative psychosocial aspects than women offered screening. This was demonstrated in a questionnaire survey where 1000 women were included: 500 women living in areas where the public authorities had never offered...... screening mammography and 500 women living in areas where women had been invited to screening mammography for >10 years. After this baseline survey, nationwide screening mammography was implemented. The aim of this follow-up study was to resurvey the 1000 women and to investigate if the identified...

  12. ScreenBEAM: a novel meta-analysis algorithm for functional genomics screens via Bayesian hierarchical modeling.

    Science.gov (United States)

    Yu, Jiyang; Silva, Jose; Califano, Andrea

    2016-01-15

    Functional genomics (FG) screens, using RNAi or CRISPR technology, have become a standard tool for systematic, genome-wide loss-of-function studies for therapeutic target discovery. As in many large-scale assays, however, off-target effects, variable reagents' potency and experimental noise must be accounted for appropriately control for false positives. Indeed, rigorous statistical analysis of high-throughput FG screening data remains challenging, particularly when integrative analyses are used to combine multiple sh/sgRNAs targeting the same gene in the library. We use large RNAi and CRISPR repositories that are publicly available to evaluate a novel meta-analysis approach for FG screens via Bayesian hierarchical modeling, Screening Bayesian Evaluation and Analysis Method (ScreenBEAM). Results from our analysis show that the proposed strategy, which seamlessly combines all available data, robustly outperforms classical algorithms developed for microarray data sets as well as recent approaches designed for next generation sequencing technologies. Remarkably, the ScreenBEAM algorithm works well even when the quality of FG screens is relatively low, which accounts for about 80-95% of the public datasets. R package and source code are available at: https://github.com/jyyu/ScreenBEAM. ac2248@columbia.edu, jose.silva@mssm.edu, yujiyang@gmail.com Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  13. Nutrition screening: science behind simplicity

    African Journals Online (AJOL)

    Nutrition screening triggers entry into the nutrition care process.1 Screening has informally been described as simple, quick or low-intensity proxy for more complex procedures. More formal definitions for the nutrition setting have been proposed, describing nutrition screening as a process of identifying patients, clients, or ...

  14. Push for the Second Screen

    DEFF Research Database (Denmark)

    Sørensen, Jannick Kirk; Sørensen, Lene Tolstrup

    Users’ perception of the relation between the TV screen and a secondary screen (e.g. smartphone or tablet) is examined empirically in a pilot project through a low-fi prototype and interviews. Early observations indicate that the user value/acceptance of push-messages delivered to the second screen...

  15. Advances in cervical screening technology.

    Science.gov (United States)

    Stoler, M H

    2000-03-01

    The Pap smear unquestionably is a successful screening test for cervical cancer. However, recent advances in technology have raised questions regarding whether the conventional Pap smear is still the standard of care. This article relates issues of screening and cost-effectiveness to the state of the art in thin layer preparations, cytology automation, human papillomavirus screening, human papillomavirus vaccines, and other cervical screening adjuncts. Perhaps nowhere in medicine is clinical decision making being more strongly influenced by market and other external forces than in cervical cytopathology.

  16. Physics in Screening Environments

    Science.gov (United States)

    Certik, Ondrej

    In the current study, we investigated atoms in screening environments like plasmas. It is common practice to extract physical data, such as temperature and electron densities, from plasma experiments. We present results that address inherent computational difficulties that arise when the screening approach is extended to include the interaction between the atomic electrons. We show that there may arise an ambiguity in the interpretation of physical properties, such as temperature and charge density, from experimental data due to the opposing effects of electron-nucleus screening and electron-electron screening. The focus of the work, however, is on the resolution of inherent computational challenges that appear in the computation of two-particle matrix elements. Those enter already at the Hartree-Fock level. Furthermore, as examples of post Hartree-Fock calculations, we show second-order Green's function results and many body perturbation theory results of second order. A self-contained derivation of all necessary equations has been included. The accuracy of the implementation of the method is established by comparing standard unscreened results for various atoms and molecules against literature for Hartree-Fock as well as Green's function and many body perturbation theory. The main results of the thesis are presented in the chapter called Screened Results, where the behavior of several atomic systems depending on electron-electron and electron-nucleus Debye screening was studied. The computer code that we have developed has been made available for anybody to use. Finally, we present and discuss results obtained for screened interactions. We also examine thoroughly the computational details of the calculations and particular implementations of the method.

  17. Glycemic screening and recurrent carbohydrate metabolism disorders with endocrine pathology

    Directory of Open Access Journals (Sweden)

    L.А. Lutsenko

    2018-03-01

    Full Text Available The use of glycated hemoglobin for diabetes mellitus (DM diagnosis is recommended by World Health Organization as of 2011. The level of glycated hemoglobin (HbA1c ≥ 6.5 % is a diagnostic criterion for DM but HbA1c level of 6.0–6.4 % does not exclude diabetes mellitus diagnosis with hyperglycemia. Moreover, when diagnosing, evaluation of this criterion is a must, since decision about the nature and the scope of sugar-reducing therapy is based on the level of HbA1c. Counterregulatory hormones are glucagon, adre­nalin, somatotropin, glucocorticoids and thyroid hormones. Pathogenic mechanism of carbohydrate metabolism disorders with hypersecretion of counterregulatory hormones is caused by peripheral insulin resistance, decrease in insulin secretion, increase in gluconeogenesis and glycogenolysis in liver and increase in the absorption of intestinal glucose with insulin being the only hormone decreasing the blood glucose. So, the endocrine diseases (hypercorticism, acromegalia, pheochromocytoma, hyperparathyroidism and hyperthyroidism with excessive secretion of counterregulatory hormones suggest the necessity of secondary diabetes diagnosis. Screening tests with quite high sensitivity and specificity have been developed for early diagnosis of endocrynopathies. Screening tests for hypercorticism diagnosis are dexamethasone (1 mg suppression test, daily urinary cortisol excretion and nighttime salivary cortisol. Optimal test for screening acromegalia is considered to be insulin-like growth factor 1 which shows the secretion of somatotropic hormone during previous day and is not subject to significant fluctuations. One-time detection of increased insulin-like growth factor 1 level compared to referential values for specific sex and age is enough for confirmation of hypersomatotropinemia. Thyroid-stimulating hormone is recommended as a screening test for thyrotoxicosis diagnosis. When choosing this test, doctor should consider the parameter of

  18. Risk and uncertainty: shifting decision making for aneuploidy screening to the first trimester of pregnancy.

    Science.gov (United States)

    Farrell, Ruth M; Dolgin, Natasha; Flocke, Susan A; Winbush, Victoria; Mercer, Mary Beth; Simon, Christian

    2011-05-01

    The clinical introduction of first trimester aneuploidy screening uniquely challenges the informed consent process for both patients and providers. This study investigated key aspects of the decision-making process for this new form of prenatal genetic screening. Qualitative data were collected by nine focus groups that comprised women of different reproductive histories (N = 46 participants). Discussions explored themes regarding patient decision making for first trimester aneuploidy screening. Sessions were audio recorded, transcribed, coded, and analyzed to identify themes. Multiple levels of uncertainty characterize the decision-making process for first trimester aneuploidy screening. Baseline levels of uncertainty existed for participants in the context of an early pregnancy and the debate about the benefit of fetal genetic testing in general. Additional sources of uncertainty during the decision-making process were generated from weighing the advantages and disadvantages of initiating screening in the first trimester as opposed to waiting until the second. Questions of the quality and quantity of information and the perceived benefit of earlier access to fetal information were leading themes. Barriers to access prenatal care in early pregnancy presented participants with additional concerns about the ability to make informed decisions about prenatal genetic testing. The option of the first trimester aneuploidy screening test in early pregnancy generates decision-making uncertainty that can interfere with the informed consent process. Mechanisms must be developed to facilitate informed decision making for this new form of prenatal genetic screening.

  19. Luminescent screens

    International Nuclear Information System (INIS)

    Lu, C.-I.

    1982-01-01

    Luminescent screens which are useful for such purposes as intensifying screens for radiographs are comprised of a support bearing a layer of finely divided particles of a phosphor dispersed in a cross-linked polymeric matrix formed by heat-curing of a coating composition comprising an unsaturated cross-linkable polymer, a polymerizable acrylic monomer, a thermoplastic polyurethane elastomer, and a heat-activatable polymerization initiator. The phosphor layer includes voids formed by evaporation of an evaporable component which is present in the coating composition from which such layer is formed. (author)

  20. Measuring lip force by oral screens Part 2: The importance of screen design, instruction and suction.

    Science.gov (United States)

    Wertsén, Madeleine; Stenberg, Manne

    2017-10-01

    The aim of this study was to find a reliable method for measuring lip force and to find the most important factors that influence the measurements in terms of magnitude and variability. The hypothesis tested was that suction is involved and thus the instruction and the design of the oral screen are of importance when measuring lip force. This is a methodological study in a healthy population. This study was conducted in a general community. The designs of the screens were soft and hard prefabricated screens and 2 semi-individually made with a tube allowing air to pass. The screens and the instructions squeeze or suck were tested on 29 healthy adults, one at a time and on 4 occasions. The test order of the screens was randomized. Data were collected during 4 consecutive days, and the procedure was repeated after 1 month. The participants were 29 healthy adult volunteers. The instruction was an important mean to distinguish between squeezing and sucking. The design of the screen affected the lip force so that it increases in relation to the projected area of the screen. A screen design with a tube allowing air to pass made it possible to avoid suction when squeezing. By measuring with and without allowing air to pass, it was possible to distinguish between suction related and not suction related lip force. The additional screen pressure when sucking was related to the ability to produce a negative intraoral pressure. In conclusion lip force increases in relation to the projected area of the screen, sucking generally increases the measured lip force and the additional screen pressure when sucking is related to the ability to produce a negative intraoral pressure.

  1. Using lessons from breast, cervical, and colorectal cancer screening to inform the development of lung cancer screening programs.

    Science.gov (United States)

    Armstrong, Katrina; Kim, Jane J; Halm, Ethan A; Ballard, Rachel M; Schnall, Mitchell D

    2016-05-01

    Multiple advisory groups now recommend that high-risk smokers be screened for lung cancer by low-dose computed tomography. Given that the development of lung cancer screening programs will face many of the same issues that have challenged other cancer screening programs, the National Cancer Institute-funded Population-based Research Optimizing Screening through Personalized Regimens (PROSPR) consortium was used to identify lessons learned from the implementation of breast, cervical, and colorectal cancer screening that should inform the introduction of lung cancer screening. These lessons include the importance of developing systems for identifying and recruiting eligible individuals in primary care, ensuring that screening centers are qualified and performance is monitored, creating clear communication standards for reporting screening results to referring physicians and patients, ensuring follow-up is available for individuals with abnormal test results, avoiding overscreening, remembering primary prevention, and leveraging advances in cancer genetics and immunology. Overall, this experience emphasizes that effective cancer screening is a multistep activity that requires robust strategies to initiate, report, follow up, and track each step as well as a dynamic and ongoing oversight process to revise current screening practices as new evidence regarding screening is created, new screening technologies are developed, new biological markers are identified, and new approaches to health care delivery are disseminated. Cancer 2016;122:1338-1342. © 2016 American Cancer Society. © 2016 American Cancer Society.

  2. How is adults’ screen time behaviour influencing their views on screen time restrictions for children? A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Stephanie Schoeppe

    2016-03-01

    Full Text Available Abstract Background High screen time in children and its detrimental health effects is a major public health problem. How much screen time adults think is appropriate for children remains little explored, as well as whether adults’ screen time behaviour would determine their views on screen time restrictions for children. This study aimed to investigate how adults’ screen time behaviour influences their views on screen time restrictions for children, including differences by gender and parental status. Methods In 2013, 2034 Australian adults participated in an online survey conducted by the Population Research Laboratory at Central Queensland University, Rockhampton. Adult screen time behaviour was assessed using the Workforce Sitting Questionnaire. Adults reported the maximum time children aged between 5–12 years should be allowed to spend watching TV and using a computer. Ordinal logistic regression was used to compare adult screen time behaviour with views on screen time restrictions for children. Results Most adults (68 % held the view that children should be allowed no more than 2 h of TV viewing and computer use on school days, whilst fewer adults (44 % thought this screen time limit is needed on weekend days. Women would impose higher screen time restrictions for children than men (p  2 h on watching TV and using the computer at home on work days (66 % and non-work days (88 %. Adults spending ≤ 2 h/day in leisure-related screen time were less likely to permit children > 2 h/day of screen time. These associations did not differ by adult gender and parental status. Conclusions Most adults think it is appropriate to limit children’s screen time to the recommended ≤ 2 h/day but few adults themselves adhere to this screen time limit. Adults with lower screen use may be more inclined to limit children’s screen time. Strategies to reduce screen time in children may also need to target adult screen use.

  3. Depression screening using the Patient Health Questionnaire-9 administered on a touch screen computer.

    Science.gov (United States)

    Fann, Jesse R; Berry, Donna L; Wolpin, Seth; Austin-Seymour, Mary; Bush, Nigel; Halpenny, Barbara; Lober, William B; McCorkle, Ruth

    2009-01-01

    To (1) evaluate the feasibility of touch screen depression screening in cancer patients using the Patient Health Questionnaire-9 (PHQ-9), (2) evaluate the construct validity of the PHQ-9 using the touch screen modality, and (3) examine the prevalence and severity of depression using this screening modality. The PHQ-9 was placed in a web-based survey within a study of the clinical impact of computerized symptom and quality of life screening. Patients in medical oncology, radiation oncology, and hematopoietic stem cell transplantation (HSCT) clinics used the program on a touch screen computer in waiting rooms prior to therapy (T1) and during therapy (T2). Responses of depressed mood or anhedonia (PHQ-2 cardinal depression symptoms) triggered additional items. PHQ-9 scores were provided to the oncology team in real time. Among 342 patients enrolled, 33 (9.6%) at T1 and 69 (20.2%) at T2 triggered the full PHQ-9 by endorsing at least one cardinal symptom. Feasibility was high, with at least 97% completing the PHQ-2 and at least 96% completing the PHQ-9 when triggered and a mean completion time of about 2 min. The PHQ-9 had good construct validity. Medical oncology patients had the highest percent of positive screens (12.9%) at T1, while HSCT patients had the highest percent (30.5%) at T2. Using this method, 21 (6.1%) at T1 and 54 (15.8%) at T2 of the total sample had moderate to severe depression. The PHQ-9 administered on a touch screen computer is feasible and provides valid depression data in a diverse cancer population. (c) 2008 John Wiley & Sons, Ltd.

  4. Patient-initiated breast cancer screening

    International Nuclear Information System (INIS)

    Chilcote, W.

    1990-01-01

    This paper reviews the results of a breast cancer screening program sponsored by organizations at workplace or community locations. A comprehensive mobile breast cancer screening program, including education, breast physical examination, and mammography, was provided to 89 local organizations at $50.00 per examination over an 18-month period. The examination was patient initiated, following the ACS screening guidelines. Estimates of eligible women were provided by each organization. A total of 5,030 women at 89 organizations were screened for breast cancer. Approximately 25,727 women were eligible

  5. Liver (Hepatocellular) Cancer Screening

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Liver (Hepatocellular) Cancer Screening (PDQ®)–Patient Version What is ... These are called diagnostic tests . General Information About Liver (Hepatocellular) Cancer Key Points Liver cancer is a ...

  6. Hearing Loss: Screening Newborns

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Hearing Loss Screening Newborns Past Issues / Spring 2015 Table ... deafness, which account for most cases. Screening Newborns' Hearing Now Standard In 1993, children born in the ...

  7. Screening for type 2 diabetes: a short report for the National Screening Committee.

    Science.gov (United States)

    Waugh, N R; Shyangdan, D; Taylor-Phillips, S; Suri, G; Hall, B

    2013-08-01

    The prevalence of type 2 diabetes mellitus (T2DM) has been increasing, owing to increases in overweight and obesity, decreasing physical activity and the changing demographic structure of the population. People can develop T2DM without symptoms and up to 20% may be undiagnosed. They may have diabetic complications, such as retinopathy, by the time they are diagnosed, or may suffer a heart attack, without warning. Undiagnosed diabetes can be detected by raised blood glucose levels. The aim of this review was to provide an update for the UK National Screening Committee (NSC) on screening for T2DM. As this review was undertaken to update a previous Health Technology Assessment review published in 2007, and a more recent Scottish Public Health Network review, searches for evidence were restricted from 2009 to end of January 2012, with selected later studies added. The databases searched were MEDLINE, EMBASE, MEDLINE-in-Process & Other Non-Indexed Citations, Science Citation Index and Conference Proceedings Citation Index. The case for screening was considered against the criteria used by the NSC to assess proposed population screening programmes. Population screening for T2DM does not meet all of the NSC criteria. Criterion 12, on optimisation of existing management, has not been met. A report by the National Audit Office (NAO) gives details of shortcomings. Criterion 13 requires evidence from high-quality randomised controlled trials that screening is beneficial. This has not been met. The Ely trial of screening showed no benefit. The ADDITION trial was not a trial of screening, but showed no benefit in cardiovascular outcomes from intensive management in people with screen-detected T2DM. Criterion 18 on staffing and facilities does not appear to have been met, according to the NAO report. Criterion 19 requires that all other options, including prevention, should have been considered. A large proportion of cases of T2DM could be prevented if people avoided becoming

  8. Can the NHS breast screening programme afford not to double read screening mammograms?

    International Nuclear Information System (INIS)

    Liston, J.C.; Dall, B.J.G.

    2003-01-01

    AIM: Rapid expansion of the National Health Service (UK) Breast Screening Programme (NHSBSP) to routinely invite women aged 50-70 years will result in many new readers undertaking screen reading. A timely method for assessing performance and preferably one that facilitates a steep learning curve will be required. MATERIALS AND METHODS: This unit screens a population of 88000 women aged 50-64 years and double reads >90% films. A record is kept of proven screen-detected cancers not recalled for assessment by either the first or second reader but correctly recalled following third-reader arbitration. Individual readers' workload and recall rates are obtained by running an annual co-writer report. The results of this 7 year prospective audit are presented. RESULTS: In total 177167 women were screened between 1/4/95 and 31/3/02 resulting in the detection of 1072 cancers. Eighty-seven cancers (8.1%) were detected after arbitration. Individual readers recall to assessment rates and percentage of cases incorrectly returned to routine recall varied. Prompt feedback of missed/misinterpreted cases allowed both experienced and inexperienced readers to modify their recall thresholds for particular mammographic abnormalities. CONCLUSION: It is recommended this audit method is adopted by all units in the NHSBSP and that the Advisory Committee for Breast Cancer Screening review the policy of single versus double reading

  9. Understanding mechanisms of toxicity: Insights from drug discovery research

    International Nuclear Information System (INIS)

    Houck, Keith A.; Kavlock, Robert J.

    2008-01-01

    Toxicology continues to rely heavily on use of animal testing for prediction of potential for toxicity in humans. Where mechanisms of toxicity have been elucidated, for example endocrine disruption by xenoestrogens binding to the estrogen receptor, in vitro assays have been developed as surrogate assays for toxicity prediction. This mechanistic information can be combined with other data such as exposure levels to inform a risk assessment for the chemical. However, there remains a paucity of such mechanistic assays due at least in part to lack of methods to determine specific mechanisms of toxicity for many toxicants. A means to address this deficiency lies in utilization of a vast repertoire of tools developed by the drug discovery industry for interrogating the bioactivity of chemicals. This review describes the application of high-throughput screening assays as experimental tools for profiling chemicals for potential for toxicity and understanding underlying mechanisms. The accessibility of broad panels of assays covering an array of protein families permits evaluation of chemicals for their ability to directly modulate many potential targets of toxicity. In addition, advances in cell-based screening have yielded tools capable of reporting the effects of chemicals on numerous critical cell signaling pathways and cell health parameters. Novel, more complex cellular systems are being used to model mammalian tissues and the consequences of compound treatment. Finally, high-throughput technology is being applied to model organism screens to understand mechanisms of toxicity. However, a number of formidable challenges to these methods remain to be overcome before they are widely applicable. Integration of successful approaches will contribute towards building a systems approach to toxicology that will provide mechanistic understanding of the effects of chemicals on biological systems and aid in rationale risk assessments

  10. Nickel-resistance determinants in Acidiphilium sp. PM identified by genome-wide functional screening.

    Directory of Open Access Journals (Sweden)

    Patxi San Martin-Uriz

    Full Text Available Acidiphilium spp. are conspicuous dwellers of acidic, metal-rich environments. Indeed, they are among the most metal-resistant organisms; yet little is known about the mechanisms behind the metal tolerance in this genus. Acidiphilium sp. PM is an environmental isolate from Rio Tinto, an acidic, metal-laden river located in southwestern Spain. The characterization of its metal resistance revealed a remarkable ability to tolerate high Ni concentrations. Here we report the screening of a genomic library of Acidiphilium sp. PM to identify genes involved in Ni resistance. This approach revealed seven different genes conferring Ni resistance to E. coli, two of which form an operon encoding the ATP-dependent protease HslVU (ClpQY. This protease was found to enhance resistance to both Ni and Co in E. coli, a function not previously reported. Other Ni-resistance determinants include genes involved in lipopolysaccharide biosynthesis and the synthesis of branched amino acids. The diversity of molecular functions of the genes recovered in the screening suggests that Ni resistance in Acidiphilium sp. PM probably relies on different molecular mechanisms.

  11. How many "Get Screened" messages does it take? Evidence from colorectal cancer screening promotion in the United States, 2012.

    Science.gov (United States)

    Cooper, Crystale Purvis; Gelb, Cynthia A; Hawkins, Nikki A

    2014-03-01

    Colorectal cancer screening has been widely promoted in the United States. We investigated the association between reported exposure to screening information during the past year and screening participation and knowledge. Data from the 2012 HealthStyles Fall survey of U.S. adults were examined using adjusted logistic regression to examine the frequency of exposure to screening information as a predictor of screening participation and knowledge; analyses were limited to participants aged ≥50years with no history of colorectal cancer or polyps (N=1714). Nearly half of the participants (44.9%) reported exposure to colorectal cancer screening information during the previous year. The most common sources of screening information were news reports, advertisements, and health care providers. Screening participation and knowledge consistently increased with the reported frequency of exposure to screening information, and these associations generally persisted when demographic variables were controlled. Compared with unexposed participants, significant gains in screening participation were associated with exposure to screening information 2-3 times (Adj. OR=1.84, p=0.001), 4-9 times (Adj. OR=2.00, p=0.001), and ≥10 times (Adj. OR=3.03, p<0.001) in the adjusted model. Increasing public exposure to screening promotion messages may augment screening participation and knowledge. Published by Elsevier Inc.

  12. Cervical cancer screening at crossroads

    DEFF Research Database (Denmark)

    Lynge, Elsebeth; Rygaard, Carsten; Baillet, Miguel Vazquez-Prada

    2014-01-01

    Cervical screening has been one of the most successful public health prevention programmes. For 50 years, cytology formed the basis for screening, and detected cervical intraepithelial lesions (CIN) were treated surgically to prevent progression to cancer. In a high-risk country as Denmark......, screening decreased the incidence of cervical cancer from 34 to 11 per 100,000, age-standardized rate (World Standard Population). Screening is, however, also expensive; Denmark (population: 5.6 million) undertakes close to half a million tests per year, and has 6-8 CIN-treated women for each prevented...... cancer case. The discovery of human papillomavirus (HPV) as the cause of cervical cancer dramatically changed perspectives for disease control. Screening with HPV testing was launched around 1990, and preventive HPV vaccination was licensed in 2006. Long-term randomized controlled trials (RCT...

  13. Mechanical Treatment: Material Recovery Facilities

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Bilitewski, B.

    2011-01-01

    A wide variety of mechanical treatment unit processes, including manual sorting, is described in Chapter 7.1. These unit processes may be used as a single separate operation (e.g. baling of recyclable cardboard) or as a single operation before or after biological and thermal treatment processes (e.......g. shredding prior to incineration or screening after composting). The mechanical treatment unit process is in the latter case an integrated part of the overall treatment usually with the purpose of improving the quality of the input material, or the efficiency or stability of the biological or thermal process......, or improving the quality of the output material. Examples hereof appear in the chapters on biological and thermal treatment. Mechanical treatment unit processes may also appear at industries using recycled material as part of their feedstock, for example, for removing impurities and homogenizing the material...

  14. Genome-wide RNAi screening identifies genes inhibiting the migration of glioblastoma cells.

    Directory of Open Access Journals (Sweden)

    Jian Yang

    Full Text Available Glioblastoma Multiforme (GBM cells are highly invasive, infiltrating into the surrounding normal brain tissue, making it impossible to completely eradicate GBM tumors by surgery or radiation. Increasing evidence also shows that these migratory cells are highly resistant to cytotoxic reagents, but decreasing their migratory capability can re-sensitize them to chemotherapy. These evidences suggest that the migratory cell population may serve as a better therapeutic target for more effective treatment of GBM. In order to understand the regulatory mechanism underlying the motile phenotype, we carried out a genome-wide RNAi screen for genes inhibiting the migration of GBM cells. The screening identified a total of twenty-five primary hits; seven of them were confirmed by secondary screening. Further study showed that three of the genes, FLNA, KHSRP and HCFC1, also functioned in vivo, and knocking them down caused multifocal tumor in a mouse model. Interestingly, two genes, KHSRP and HCFC1, were also found to be correlated with the clinical outcome of GBM patients. These two genes have not been previously associated with cell migration.

  15. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  16. Screen for Disordered Eating: Improving the accuracy of eating disorder screening in primary care.

    Science.gov (United States)

    Maguen, Shira; Hebenstreit, Claire; Li, Yongmei; Dinh, Julie V; Donalson, Rosemary; Dalton, Sarah; Rubin, Emma; Masheb, Robin

    To develop a primary care eating disorder screen with greater accuracy and greater potential for generalizability, compared to existing screens. Cross-sectional survey to assess discriminative accuracy of a new screen, Screen for Disordered Eating (SDE), compared to Eating Disorders Screen for Primary Care (EDS-PC) and SCOFF screener, using prevalence rates of Binge Eating Disorder (BED), Bulimia Nervosa (BN), Anorexia Nervosa (AN), and Any Eating Disorder (AED), as measured by the Eating Disorder Examination Questionnaire (EDE-Q). The SDE correctly classified 87.2% (CI: 74.3%-95.2%) of BED cases, all cases of BN and AN, and 90.5% (CI: 80.4%-96.4%) of AED cases. Sensitivity estimates were higher than the SCOFF, which correctly identified 69.6% (CI: 54.2%-82.3%) of BED, 77.8% (CI: 40.0%-97.2%) of BN, 37.5% (CI: 8.52%-75.5%) of AN, and 66.1% (CI: 53%-77.7%) of AED. While the EDS-PC had slightly higher sensitivity than the SDE, the SDE had better specificity. The SDE outperformed the SCOFF in classifying true cases, the EDS-PC in classifying true non-cases, and the EDS-PC in distinguishing cases from non-cases. The SDE is the first screen, inclusive of BED, valid for detecting eating disorders in primary care. Findings have broad implications to address eating disorder screening in primary care settings. Published by Elsevier Inc.

  17. Breast cancer screening in older women.

    Science.gov (United States)

    Caplan, L S; Haynes, S G

    1996-01-01

    There is currently an epidemic of breast cancer in women 65 years of age and older. The purposes of this paper are to explore the breast cancer screening behaviors of older women and to identify some of the determinants of screening in these women. Data were analyzed from the 1987 National Health Interview Survey, a continuous nationwide household interview survey of the U.S. civilian, noninstitutionalized population. As in other studies, the utilization of breast cancer screening by older women was less in older women than in younger women. This was true for both mammography and clinical breast examination. A number of determinants of screening in older women were identified here. Women with a usual source of care and/or no activity limitation, as well as high school graduates, were the ones most likely to have received a screening mammogram and/or a screening clinical breast exam during the past year. The failure of older women to receive adequate breast cancer screening is an important concern which should be reevaluated, given the breast cancer epidemic in this population. This study identified a number of determinants of breast cancer screening in older women. For the most part, these determinants point to the primary care physician as the key to breast cancer screening in these women. Therefore, the primary care physician must be informed of, and encouraged to follow, the recommendations for periodic breast cancer screening in older women.

  18. Characteristics of screen media use associated with higher BMI in young adolescents.

    Science.gov (United States)

    Bickham, David S; Blood, Emily A; Walls, Courtney E; Shrier, Lydia A; Rich, Michael

    2013-05-01

    This study investigates how characteristics of young adolescents' screen media use are associated with their BMI. By examining relationships between BMI and both time spent using each of 3 screen media and level of attention allocated to use, we sought to contribute to the understanding of mechanisms linking media use and obesity. We measured heights and weights of 91 13- to 15-year-olds and calculated their BMIs. Over 1 week, participants completed a weekday and a Saturday 24-hour time-use diary in which they reported the amount of time they spent using TV, computers, and video games. Participants carried handheld computers and responded to 4 to 7 random signals per day by completing onscreen questionnaires reporting activities to which they were paying primary, secondary, and tertiary attention. Higher proportions of primary attention to TV were positively associated with higher BMI. The difference between 25th and 75th percentiles of attention to TV corresponded to an estimated +2.4 BMI points. Time spent watching television was unrelated to BMI. Neither duration of use nor extent of attention paid to video games or computers was associated with BMI. These findings support the notion that attention to TV is a key element of the increased obesity risk associated with TV viewing. Mechanisms may include the influence of TV commercials on preferences for energy-dense, nutritionally questionable foods and/or eating while distracted by TV. Interventions that interrupt these processes may be effective in decreasing obesity among screen media users.

  19. Mobile ultra-clean unidirectional airflow screen reduces air contamination in a simulated setting for intra-vitreal injection.

    Science.gov (United States)

    Lapid-Gortzak, Ruth; Traversari, Roberto; van der Linden, Jan Willem; Lesnik Oberstein, Sarit Y; Lapid, Oren; Schlingemann, Reinier O

    2017-02-01

    The aim of this study is to determine whether the use of a mobile ultra-clean laminar airflow screen reduces the air-borne particle counts in the setting of a simulated procedure of an intra-vitreal injection. A mobile ultra-clean unidirectional airflow (UDF) screen was tested in a simulated procedure for intra-vitreal injections in a treatment room without mechanical ventilation. One UDF was passed over the instrument tray and the surgical area. The concentration of particles was measured in the background, over the instrument table, and next to the ocular area. The degree of protection was calculated at the instrument table and at the surgical site. Use of the UDF mobile screen reduced the mean particle concentration (particles > 0.3 microns) on the instrument table by a factor of at least 100.000 (p air contamination. Mobile UDF screen reduces the mean particle concentration substantially. The mobile UDF screen may therefore allow for a safer procedural environment for ambulatory care procedures such as intra-vitreal injections in treatment rooms.

  20. Knowledge of colorectal cancer screening guidelines and intention to obtain screening among nonadherent Filipino, Hmong, and Korean Americans.

    Science.gov (United States)

    Tsoh, Janice Y; Tong, Elisa K; Sy, Angela U; Stewart, Susan L; Gildengorin, Ginny L; Nguyen, Tung T

    2018-04-01

    Nonadherence to colorectal cancer (CRC) screening among Asian Americans is high but not well understood. This study examined correlates of screening intention among Filipino, Hmong, and Korean Americans who were nonadherent to CRC screening. Using cross-sectional, preintervention survey data from 504 Asian Americans (115 Filipinos, 185 Hmong, and 204 Koreans) aged 50-75 years who were enrolled in a multisite cluster randomized controlled trial of lay health educator intervention, we analyzed correlates of self-reported CRC screening nonadherence, which was defined as not being up-to-date for fecal occult blood test, sigmoidoscopy, or colonoscopy. Only 26.8% of participants indicated intention to obtain screening within 6 months (Hmong: 12.4%; Korean: 30.8%; and Filipino: 42.6%; P Filipinos, which was unexplained by socio-demographics, health care factors, perceived needs for CRC screening, or knowledge of screening guidelines. CRC screening intention among nonadherent Filipino, Hmong, and Korean Americans was low. Targeting knowledge of CRC screening guidelines may be effective strategies for increasing CRC screening intention among nonadherent Asian Americans. Cancer 2018;124:1560-7. © 2018 American Cancer Society. © 2018 American Cancer Society.

  1. The impact of radiologists' expertise on screen results decisions in a CT lung cancer screening trial

    International Nuclear Information System (INIS)

    Heuvelmans, Marjolein A.; Vliegenthart, Rozemarijn; Oudkerk, Matthijs; Jong, Pim A. de; Mali, Willem P.; Groen, Harry J.M.

    2015-01-01

    To evaluate the impact of radiological expertise on screen result decisions in a CT lung cancer screening trial. In the NELSON lung cancer screening trial, the baseline CT result was based on the largest lung nodule's volume. The protocol allowed radiologists to manually adjust screen results in cases of high suspicion of benign or malignant nodule nature. Participants whose baseline CT result was based on a solid or part-solid nodule were included in this study. Adjustments by radiologists at baseline were evaluated. Histology was the reference for diagnosis or to confirm benignity and stability on subsequent CT examinations. A total of 3,318 participants (2,796 male, median age 58.0 years) were included. In 195 participants (5.9 %) the initial baseline screen result was adjusted by the radiologist. Adjustment was downwards from positive or indeterminate to negative in two and 119 participants, respectively, and from positive to indeterminate in 65 participants. None of these nodules turned out to be malignant. In 9/195 participants (4.6 %) the screen result was adjusted upwards from negative to indeterminate or indeterminate to positive; two nodules were malignant. In one in 20 cases of baseline lung cancer screening, nodules were reclassified by the radiologist, leading to a reduction of false-positive screen results. (orig.)

  2. Screening for diabetes in unconventional locations: resource implications and economics of screening in optometry practices.

    Science.gov (United States)

    Howse, Jennifer H; Jones, Steve; Hungin, A Pali S

    2011-10-01

    Unconventional locations outwith general medical practice may prove opportunities for screening. The aim was to determine the resource implications and economics of a screening service using random capillary blood glucose (rCBG) tests to detect raised blood glucose levels in the "at risk" population attending high street optometry practices. A screening service was implemented in optometry practices in North East England: the cost of the service and the implication of different screening strategies was estimated. The cost of a screening test was £5.53-£11.20, depending on the screening strategy employed and who carried out the testing. Refining the screening strategy to target those ≥40 years with BMI of ≥25 kg/m(2) and/or family history of diabetes resulted in a cost per case referred to the GP of £14.38-£26.36. Implementing this strategy in half of optometric practices in England would have the potential to identify up to 150,000 new cases of diabetes and prediabetes a year. Optometry practices provide an effective way of identifying people who would benefit from further investigation for diabetes. Effectiveness could be improved further by improving cooperation and communication between optometrists and medical practitioners. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. The paradox of screening: Rural women's views on screening for postnatal depression

    Directory of Open Access Journals (Sweden)

    Small Rhonda E

    2010-12-01

    Full Text Available Abstract Background Universal screening for postnatal depression is currently being promoted in Australia to assist detection and treatment of affected women, yet debate continues internationally about the effectiveness of screening. One rural shire in Victoria has been screening all women for postnatal depression at maternal and child health checks for many years. This paper explores the views of women affected by this intervention. Methods A postal survey was sent to an entire one year cohort of women resident in the shire and eligible for this program [n = 230]. Women were asked whether they recalled having been screened for postnatal depression and what their experience had been, including any referrals made as a result of screening. Women interested in providing additional information were invited to give a phone number for further contact. Twenty women were interviewed in-depth about their experiences. The interview sample was selected to include both depressed and non-depressed women living in town and on rural properties, who represented the range of circumstances of women living in the shire. Results The return rate for the postal survey was 62% [n = 147/230]. Eighty-seven women indicated that they were interested in further contact, 80 of whom were able to be reached by telephone and 20 were interviewed in-depth. Women had diverse views and experiences of screening. The EPDS proved to be a barrier for some women, and a facilitator for others, in accessing support and referrals. The mediating factor appeared to be a trusting relationship with the nurse able to communicate her concern for the woman and offer support and referrals if required. Conclusions Detection of maternal depression requires more than administration of a screening tool at a single time point. While this approach did work for some women, for others it actually made appropriate care and support more difficult. Rather, trained and empathic healthcare providers working

  4. X-ray screening materials

    International Nuclear Information System (INIS)

    Wardley, R.B.

    1981-01-01

    This invention relates to x-ray screening materials and especially to materials in sheet form for use in the production of, for example, protective clothing such as aprons and lower back shields, curtains, mobile screens and suspended shields. The invention is based on the observation that x-ray screening materials in sheet form having greater flexiblity than the hitherto known x-ray screening materials of the same x-ray absorber content can be produced if, instead of using a single sheet of filled sheet material of increased thickness, one uses a plurality of sheets of lesser thickness together forming a laminar material of the desired thickness and one bonds the individual sheets together at their edges and, optionally, at other spaced apart points away from the edges thereby allowing one sheet to move relative to another. (U.K.)

  5. Industrial screening programs for workers

    International Nuclear Information System (INIS)

    Lavine, M.P.

    1982-01-01

    Industrial screening efforts to identify classes of workers who are more susceptible to workplace hazards, by virtue of their fertility, genetic, or lifestyle characteristics, represent a relatively new approach to reducing workplace risks. Screening has already raised some important economic, legal, social, medical, and moral questions. Employers, employees, administrative agencies, and the courts are offering different, often conflicting answers. Ultimately the acceptability of various screening schemes rests upon judgments about how a society justifies the distribution of risk. The questions that industrial screening programs raise are only partially answered by empirical evidence; the rest is a matter of values

  6. Wearable Wireless Tyrosinase Bandage and Microneedle Sensors: Toward Melanoma Screening.

    Science.gov (United States)

    Ciui, Bianca; Martin, Aida; Mishra, Rupesh K; Brunetti, Barbara; Nakagawa, Tatsuo; Dawkins, Thomas J; Lyu, Mengjia; Cristea, Cecilia; Sandulescu, Robert; Wang, Joseph

    2018-04-01

    Wearable bendable bandage-based sensor and a minimally invasive microneedle biosensor are described toward rapid screening of skin melanoma. These wearable electrochemical sensors are capable of detecting the presence of the tyrosinase (TYR) enzyme cancer biomarker in the presence of its catechol substrate, immobilized on the transducer surface. In the presence of the surface TYR biomarker, the immobilized catechol is rapidly converted to benzoquinone that is detected amperometrically, with a current signal proportional to the TYR level. The flexible epidermal bandage sensor relies on printing stress-enduring inks which display good resiliency against mechanical deformations, whereas the hollow microneedle device is filled with catechol-coated carbon paste for assessing tissue TYR levels. The bandage sensor can thus be used directly on the skin whereas microneedle device can reach melanoma tissues under the skin. Both wearable sensors are interfaced to an ultralight flexible electronic board, which transmits data wirelessly to a mobile device. The analytical performance of the resulting bandage and microneedle sensing systems are evaluated using TYR-containing agarose phantom gel and porcine skin. The new integrated conformal portable sensing platforms hold considerable promise for decentralized melanoma screening, and can be extended to the screening of other key biomarkers in skin moles. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Targeting health subsidies through a non-price mechanism: A randomized controlled trial in Kenya

    Science.gov (United States)

    Dupas, Pascaline; Hoffmann, Vivian; Kremer, Michael; Zwane, Alix Peterson

    2016-01-01

    Free provision of preventive health products can dramatically increase access in low income countries. A cost concern about free provision is that some recipients may not use the product, wasting resources (over-inclusion). Yet charging a price to screen out non-users may screen out poor people who need and would use the product (over-exclusion). We report on a randomized controlled trial of a screening mechanism that combines the free provision of chlorine solution for water treatment with a small non-monetary cost (household vouchers that need to be redeemed monthly in order). Relative to a non-voucher free distribution program, this mechanism reduces the quantity of chlorine procured by 60 percentage points, but reduces the share of households whose stored water tests positive for chlorine residual by only one percentage point, dramatically improving the tradeoff between over-inclusion and over-exclusion. PMID:27563091

  8. International Cancer Screening Network

    Science.gov (United States)

    The International Cancer Screening Network promotes evidence-based cancer screening implementation and evaluation with cooperation from multilateral organizations around the globe. Learn more about how ICSN aims to reduce the global burden of cancer by supporting research and international collaboration.

  9. Quest of novel GH20 N-acetyl hexosaminidasetransglycosylating catalysts: functional screening, data mining and semi-rational mutagenesis

    DEFF Research Database (Denmark)

    Teze, David; Visnapuu, Triinu; Kjeldsen, Christian

    and the fact that the products are also substrates, thus needing a kinetic control of the reaction. Several approaches have been developed to overcome these, including mechanism modifications (e.g. glycosynthases, chemical rescue), functional screening and data mining to find natural transglycosidases...... been reported. Thus, we turned to discovery and characterization of new GH20s and performing a systematic mutagenesis study. Several new GH20s of bacterial origin were isolated and described by functional screening and data mining, including transglycosidases able to synthesize lacto...

  10. Domestic violence screening in pregnancy.

    Science.gov (United States)

    Bunn, Mikiko Yazawa; Higa, Nicole A; Parker, Willie J; Kaneshiro, Bliss

    2009-11-01

    Domestic violence is an important health concern that has been shown to have adverse effects on maternal and neonatal outcomes. The objectives of this study were to compare the prevalence of prenatal screening for domestic violence in a hospital-based resident clinic setting with screening practices in private obstetric offices in Honolulu, Hawai'i and to explore physician attitudes towards domestic violence screening during pregnancy. A retrospective chart review was conducted at Queen's Medical Center in Honolulu, Hawai'i in women who delivered between 2003 and 2004. A 6 item written survey was also given to all attending and resident physicians with obstetric privileges. Descriptive statistics including frequency measures were generated and chi square tests were used to compare categorical variables. A total of 270 charts were reviewed. There was a statistically significant difference (p obstetric practices (39.3 percent) that were screened for domestic violence. While the majority of respondents (77.6%) to the domestic violence survey were aware that the American College of Obstetricians and Gynecologists recommends domestic violence screening in pregnancy most respondents (69.0 percent) indicated that they "never or rarely" screened their patients for domestic violence. Despite professional recommendations and an awareness of these recommendations, between 2003 and 2004, routine prenatal screening for domestic violence was markedly lacking for patients in this study population.

  11. Greening the Screen: An Environmental Challenge

    Directory of Open Access Journals (Sweden)

    Ekin Gündüz Özdemirci

    2016-06-01

    Full Text Available Environmental themes and representations on screen are examined as a part of environmental social studies and can be considered a way of creating awareness of environmental issues. However, how often do we consider the environmental impact of a film or television shoot as an industrial process? In this article, I examine the sustainability practices in the motion picture industry and challenges to that by focusing on the British film and television industry as a case study. Using the interviews with industry representatives and some case studies, I discuss the possibilities of creating a change in behavior in the film industry, not only in terms of embedding green measures but also reconstituting industrial mechanisms on behalf of environmental sustainability.

  12. Radiographic intensifying screens

    International Nuclear Information System (INIS)

    Van Landeghem, W.K.; Suys, A.R.

    1979-01-01

    A fluorescent x-ray image intensifying screen is described which comprises discrete particles of fluorescent material dispersed in a binder layer. Intensifying screens are employed to increase the exposure of a photosensitive plate or film without increasing the x-ray exposure dose when struck by x-rays. The screen has an outermost layer containing solid particulate material protruding from a coherent film-forming organic binder medium and having a static friction coefficient at room temperature not higher than 0.50 on steel. The outermost layer may be characterized by micro-unevennesses of at least 3 μm and at least 9 protruding particles per 0.35 sq. cm. These particles have a static friction coefficient less than 0.3 and are made of a solid polystyrene, polyaklylene and/or a solid organic fluorinated polymer. (JTA)

  13. Unifying screening processes within the PROSPR consortium: a conceptual model for breast, cervical, and colorectal cancer screening.

    Science.gov (United States)

    Beaber, Elisabeth F; Kim, Jane J; Schapira, Marilyn M; Tosteson, Anna N A; Zauber, Ann G; Geiger, Ann M; Kamineni, Aruna; Weaver, Donald L; Tiro, Jasmin A

    2015-06-01

    General frameworks of the cancer screening process are available, but none directly compare the process in detail across different organ sites. This limits the ability of medical and public health professionals to develop and evaluate coordinated screening programs that apply resources and population management strategies available for one cancer site to other sites. We present a trans-organ conceptual model that incorporates a single screening episode for breast, cervical, and colorectal cancers into a unified framework based on clinical guidelines and protocols; the model concepts could be expanded to other organ sites. The model covers four types of care in the screening process: risk assessment, detection, diagnosis, and treatment. Interfaces between different provider teams (eg, primary care and specialty care), including communication and transfer of responsibility, may occur when transitioning between types of care. Our model highlights across each organ site similarities and differences in steps, interfaces, and transitions in the screening process and documents the conclusion of a screening episode. This model was developed within the National Cancer Institute-funded consortium Population-based Research Optimizing Screening through Personalized Regimens (PROSPR). PROSPR aims to optimize the screening process for breast, cervical, and colorectal cancer and includes seven research centers and a statistical coordinating center. Given current health care reform initiatives in the United States, this conceptual model can facilitate the development of comprehensive quality metrics for cancer screening and promote trans-organ comparative cancer screening research. PROSPR findings will support the design of interventions that improve screening outcomes across multiple cancer sites. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  14. TeraSCREEN: multi-frequency multi-mode Terahertz screening for border checks

    Science.gov (United States)

    Alexander, Naomi E.; Alderman, Byron; Allona, Fernando; Frijlink, Peter; Gonzalo, Ramón; Hägelen, Manfred; Ibáñez, Asier; Krozer, Viktor; Langford, Marian L.; Limiti, Ernesto; Platt, Duncan; Schikora, Marek; Wang, Hui; Weber, Marc Andree

    2014-06-01

    The challenge for any security screening system is to identify potentially harmful objects such as weapons and explosives concealed under clothing. Classical border and security checkpoints are no longer capable of fulfilling the demands of today's ever growing security requirements, especially with respect to the high throughput generally required which entails a high detection rate of threat material and a low false alarm rate. TeraSCREEN proposes to develop an innovative concept of multi-frequency multi-mode Terahertz and millimeter-wave detection with new automatic detection and classification functionalities. The system developed will demonstrate, at a live control point, the safe automatic detection and classification of objects concealed under clothing, whilst respecting privacy and increasing current throughput rates. This innovative screening system will combine multi-frequency, multi-mode images taken by passive and active subsystems which will scan the subjects and obtain complementary spatial and spectral information, thus allowing for automatic threat recognition. The TeraSCREEN project, which will run from 2013 to 2016, has received funding from the European Union's Seventh Framework Programme under the Security Call. This paper will describe the project objectives and approach.

  15. DEVELOPMENT OF A REPRODUCIBLE SCREENING METHOD TO DETERMINE THE MECHANISM AND EFFECT OF ORGANIC ACIDS AND OTHER CONTAMINANTS ON THE CORROSION OF ALUMINUM-FINNED COPPER-TUBE HEAT EXCHANGE COILS

    Energy Technology Data Exchange (ETDEWEB)

    Richard A. Corbett; Dave Severance

    2005-02-01

    Formicary corrosion is an insidious form of localized pitting corrosion. Notoya (1997b) wrote, ?In Japan, this type of corrosion is found in approximately 10% of cases of premature failure of copper tubes.? Attack characteristically features very small surface pits which are not visible to the un-aided eye, and random directional changes in the underlying copper metal. Attack is rapid. Failures have occurred before installation, shortly thereafter, or within several years later. Objectives of this Research Project Conduct an in depth literature search on the subject of formicary corrosion. Define the corrosion mechanism. Develop a test method that will reproduce formicary corrosion. Develop a test method for screening candidate materials that could cause formicary corrosion.

  16. Newborn screening for galactosaemia.

    Science.gov (United States)

    Lak, Rohollah; Yazdizadeh, Bahareh; Davari, Majid; Nouhi, Mojtaba; Kelishadi, Roya

    2017-12-23

    Classical galactosaemia is an autosomal recessive inborn error of metabolism caused by a deficiency of the enzyme galactose-1-phosphate uridyltransferase. This is a rare and potentially lethal condition that classically presents in the first week of life once milk feeds have commenced. Affected babies may present with any or all of the following: cataracts; fulminant liver failure; prolonged jaundice; or Escherichia coli sepsis. Once the diagnosis is suspected, feeds containing galactose must be stopped immediately and replaced with a soya-based formula. The majority of babies will recover, however a number will not survive. There are long-term complications of galactosaemia, despite treatment, including learning disabilities and female infertility. It has been postulated that galactosaemia could be detected on newborn screening and this would prevent the immediate severe liver dysfunction and sepsis. To assess whether there is evidence that newborn screening for galactosaemia prevents or reduces mortality and morbidity and improves clinical outcomes in affected neonates and the quality of life in older children. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from electronic database searches, handsearches of relevant journals and conference abstract books. We also searched online trials registries and the reference lists of relevant articles and reviews.Date of the most recent search of Cochrane Cystic Fibrosis Group's Trials Register: 18 December 2017.Date of the most recent search of additional resources: 11 October 2017. Randomised controlled studies and controlled clinical studies, published or unpublished comparing the use of any newborn screening test to diagnose infants with galactosaemia and presenting a comparison between a screened population versus a non-screened population. No studies of newborn screening for galactosaemia were found. No studies were identified for inclusion in the

  17. School-Based Screening to Identify At-Risk Students Not Already Known to School Professionals: The Columbia Suicide Screen

    Science.gov (United States)

    Wilcox, Holly C.; Schonfeld, Irvin Sam; Davies, Mark; Hicks, Roger C.; Turner, J. Blake; Shaffer, David

    2009-01-01

    Objectives. We sought to determine the degree of overlap between students identified through school-based suicide screening and those thought to be at risk by school administrative and clinical professionals. Methods. Students from 7 high schools in the New York metropolitan area completed the Columbia Suicide Screen; 489 of the 1729 students screened had positive results. The clinical status of 641 students (73% of those who had screened positive and 23% of those who had screened negative) was assessed with modules from the Diagnostic Interview Schedule for Children. School professionals nominated by their principal and unaware of students' screening and diagnostic status were asked to indicate whether they were concerned about the emotional well-being of each participating student. Results. Approximately 34% of students with significant mental health problems were identified only through screening, 13.0% were identified only by school professionals, 34.9% were identified both through screening and by school professionals, and 18.3% were identified neither through screening nor by school professionals. The corresponding percentages among students without mental health problems were 9.1%, 24.0%, 5.5%, and 61.3%. Conclusions. School-based screening can identify suicidal and emotionally troubled students not recognized by school professionals. PMID:19059865

  18. Yield and Efficiency of Mental Health Screening: A Comparison of Screening Protocols at Intake to Prison.

    Science.gov (United States)

    Martin, Michael S; Potter, Beth K; Crocker, Anne G; Wells, George A; Colman, Ian

    2016-01-01

    The value of screening for mental illness has increasingly been questioned in low prevalence settings due to high false positive rates. However, since false positive rates are related to prevalence, screening may be more effective in higher prevalence settings, including correctional institutions. We compared the yield (i.e. newly detected cases) and efficiency (i.e. false positives) of five screening protocols to detect mental illness in prisons against the use of mental health history taking (the prior approach to detecting mental illness). We estimated the accuracy of the six approaches to detect an Axis I disorder among a sample of 467 newly admitted male inmates (83.1% participation rate). Mental health history taking identified only 41.0% (95% CI 32.1, 50.6) of all inmates with mental illness. Screening protocols identified between 61.9 and 85.7% of all cases, but referred between 2 and 3 additional individuals who did not have a mental illness for every additional case detected compared to the mental health history taking approach. In low prevalence settings (i.e. 10% or less) the screening protocols would have had between 4.6 and 16.2 false positives per true positive. While screening may not be practical in low prevalence settings, it may be beneficial in jails and prisons where the prevalence of mental illness is higher. Further consideration of the context in which screening is being implemented, and of the impacts of policies and clinical practices on the benefits and harms of screening is needed to determine the effectiveness of screening in these settings.

  19. Yield and Efficiency of Mental Health Screening: A Comparison of Screening Protocols at Intake to Prison.

    Directory of Open Access Journals (Sweden)

    Michael S Martin

    Full Text Available The value of screening for mental illness has increasingly been questioned in low prevalence settings due to high false positive rates. However, since false positive rates are related to prevalence, screening may be more effective in higher prevalence settings, including correctional institutions. We compared the yield (i.e. newly detected cases and efficiency (i.e. false positives of five screening protocols to detect mental illness in prisons against the use of mental health history taking (the prior approach to detecting mental illness.We estimated the accuracy of the six approaches to detect an Axis I disorder among a sample of 467 newly admitted male inmates (83.1% participation rate. Mental health history taking identified only 41.0% (95% CI 32.1, 50.6 of all inmates with mental illness. Screening protocols identified between 61.9 and 85.7% of all cases, but referred between 2 and 3 additional individuals who did not have a mental illness for every additional case detected compared to the mental health history taking approach. In low prevalence settings (i.e. 10% or less the screening protocols would have had between 4.6 and 16.2 false positives per true positive.While screening may not be practical in low prevalence settings, it may be beneficial in jails and prisons where the prevalence of mental illness is higher. Further consideration of the context in which screening is being implemented, and of the impacts of policies and clinical practices on the benefits and harms of screening is needed to determine the effectiveness of screening in these settings.

  20. Preconception carrier screening for multiple disorders: evaluation of a screening offer in a Dutch founder population.

    Science.gov (United States)

    Mathijssen, Inge B; Holtkamp, Kim C A; Ottenheim, Cecile P E; van Eeten-Nijman, Janneke M C; Lakeman, Phillis; Meijers-Heijboer, Hanne; van Maarle, Merel C; Henneman, Lidewij

    2018-02-01

    Technological developments have enabled carrier screening for multiple disorders. This study evaluated experiences with a preconception carrier screening offer for four recessive disorders in a Dutch founder population. Questionnaires were completed by 182 attendees pretesting and posttesting and by 137 non-attendees. Semistructured interviews were conducted with seven of the eight carrier couples. Attendees were mainly informed about the existence of screening by friends/colleagues (49%) and family members (44%). Familiarity with the genetic disorders was high. Knowledge after counseling increased (p influencers (family/friends) can be used to raise awareness of a screening offer. Our findings provide lessons for the implementation of expanded carrier screening panels in other communities and other settings.

  1. Screening of Modified RNA duplexes

    DEFF Research Database (Denmark)

    Schyth, Brian Dall; Bramsen, Jesper Bertram; Kjems, Jørgen

    protection against a fish pathogenic virus. This protection corresponded with an interferon response in the fish. Here we use this fish model to screen siRNAs containing various chemical modifications of the RNA backbone for their antiviral activity, the overall aim being identification of an siRNA form......Because of sequence specific gene targeting activity siRNAs are regarded as promising active compounds in gene medicine. But one serious problem with delivering siRNAs as treatment is the now well-established non-specific activities of some RNA duplexes. Cellular reactions towards double stranded...... RNAs include the 2´-5´ oligoadenylate synthetase system, the protein kinase R, RIG-I and Toll-like receptor activated pathways all resulting in antiviral defence mechanism. We have previously shown that antiviral innate immune reactions against double stranded RNAs could be detected in vivo as partial...

  2. One more hurdle to increasing mammography screening: pubescent, adolescent, and prior mammography screening experiences.

    Science.gov (United States)

    Thomas, Eileen; Usher, LaToya

    2009-01-01

    Approximately $8.1 billion dollars is spent each year in the United States alone on the treatment of breast cancer. Survival rates are dependent on access to, and utilization of, early detection services. The primary reason for disparity in breast cancer mortality is the delay in time to diagnosis, resulting in poor prognosis. Despite ongoing research to understand barriers to mammography screening, recent studies report a decrease in mammography screening among all racial groups. A qualitative approach was used to elicit information from 36 White non- Hispanic, African-American, Hispanic, and Native American women without a history of breast cancer. Women were invited to share written or audiotape-recorded narratives about experiences pertaining to their breasts and their mammography screening experiences. Major categories identified were: teasing, family norms and values, media/societal influence, body image, and mammography screening experiences. The resulting effects of these experiences left these women with feelings of shame and "conflict" regarding their breasts. The major theme identified was breast conflict. Findings suggest that breast conflict may persist throughout the lifespan and can have a negative influence on a woman's decision to participate in mammography screening. The authors hypothesize that experiences that occur during adolescence pertaining to young girls' breasts can influence a women's body image, which in turn can later in life affect health-seeking behaviors related to mammography screening. These findings have implications for public health practice in planning for breast cancer screening, education, and interventions for women from diverse racial/ethnics groups.

  3. Cervical cancer screening and Chinese women: Insights from focus groups

    Directory of Open Access Journals (Sweden)

    Sabrina Chia Hsuan Chang

    2013-02-01

    Full Text Available Objective: Despite extensive efforts to raise awareness, Papanicolaou (Pap testing rates among Chinese women living in North America remain low compared with Euro-American women. Although the lower Pap testing rate and ensuing health repercussions among Chinese women are well characterized, mechanisms underlying such health disparities are not. The aim of this study was to use a qualitative approach to delineate such mechanisms. Qualitative approaches to understand constructs within the domain of sexual and reproductive health have been shown to be particularly appropriate, and offer a nuanced view of sexuality that is not afforded by traditional quantitative methods.Method: We carried out two focus groups aimed at exploring how Mandarin-speaking and English-speaking Chinese women experience Pap testing (N = 12. The women were invited to partake in the focus groups from having participated in a large-scale quantitative study. We used content analyses to analyze transcripts and extract themes. Results: The women heavily endorsed Chinese medicine philosophy, conceptualizing physical health holistically, and valuing preventative measures over screening and interceptive measures. Pap testing was described as qualitatively different from other screening procedures, such that women assigned a sexually charged meaning to Pap testing, often discussing it in relation to sexual activity and promiscuity. Women expressed their preference for the compulsory and depersonalized manner that Pap tests are performed in their home country of China, as this lessens the embarrassment associated with undergoing Pap testing. Conclusion: Three mechanisms may contribute to lower Pap testing among Chinese women: preference for Chinese medicine philosophy, perceived sexualization of Pap testing, and the institutionalization of medical care. Implications for improving the reproductive health of Chinese women are discussed.

  4. Newborn Screening: MedlinePlus Health Topic

    Science.gov (United States)

    ... more articles Reference Desk Glossary (National Center for Biotechnology Information) Find an Expert Eunice Kennedy Shriver National ... other than English on Newborn Screening NIH MedlinePlus Magazine Hearing Loss: Screening Newborns Screening Newborns' Hearing Now ...

  5. Fish screens at hydroelectric diversions

    International Nuclear Information System (INIS)

    Ott, R.F.

    1994-01-01

    Preventing downstream migrating fish from entering the turbines at hydroelectric projects is a standard mitigation goal of state and federal fishery management agencies. The object is to minimize the adverse impacts to the fish associated with the exclusion and passage through the bypass water conveyance facilities. In the western United States, most of the fishery management agencies have fish screen design criteria that focus on the approach and transportational velocities, maximum opening dimensions of the screen material, and the cleaning standards. Recently, more attention has been given to fish behavioral traits such as attraction and sustained and darting swimming speed, which has resulted in more attention to the position of the screens to the flow and the length of time the downstream migrants are exposed to the screens. Criteria for length of time of exposure, size and position of bypass, flow and velocities in the bypass entrances, discharge requirements back into the receiving water, and exposure to predation have created unique challenges to the fish screen designer. This paper discusses some of the more recent types of fixed fish screens that are being installed at hydroelectric plants that meet these challenges

  6. Mechanic-electrical transformations in the Kelvin method

    Energy Technology Data Exchange (ETDEWEB)

    Zharkikh, Yu. S., E-mail: yurzhar@gmail.com [Faculty of Radio Physics, Electronics and Computer Systems, Taras Shevchenko National University of Kyiv, 4G, Ave. Academician Glushkov, 03127, Kyiv (Ukraine); Lysochenko, S.V., E-mail: lys@univ.kiev.ua [Institute of High Technologies, Taras Shevchenko National University of Kyiv, 4G, Ave. Academician Glushkov, 03127, Kyiv (Ukraine)

    2017-04-01

    Highlights: • Used in Kelvin method dynamic capacitor is a mechanic-electrical transformer. • The oscillations of its plate are source of extraneous forces which cause the appearance of an electric current. • The signal is caused not by the contact potential difference, but by oscillation in the screening conditions of charge in the dynamic capacitor gap. • Combining the Kelvin method with electron emission methods to determine the work function may lead to incorrectness. - Abstract: To explain the initiation mechanism of alternating current in an electric circuit containing the dynamic capacitor a model of mechanic- electrical transformation is suggested to use. In such a model, electric charges disposed between the capacitor plates serve as a cause of measured signal in contrast to the contact potential difference, which is considered as the main base in the Kelvin’s model. If one of the plates moves periodically, then the conditions of the charges screening are changed and thereby the capacitor recharging current is arise. The measuring is based on compensation of the recharging current by current, which generated by a source of electromotive force (EMF). The compensation voltage depends on both the distribution of ions or dipoles over the studied surface and the charges creating the surface potential barrier. This voltage is independent on the bulk electro-physical characteristics of a solid.

  7. High Content Screening: Understanding Cellular Pathway

    International Nuclear Information System (INIS)

    Mohamed Zaffar Ali Mohamed Amiroudine; Daryl Jesus Arapoc; Zainah Adam; Shafii Khamis

    2015-01-01

    High content screening (HCS) is the convergence between cell-based assays, high-resolution fluorescence imaging, phase-contrast imaging of fixed- or live-cell assays, tissues and small organisms. It has been widely adopted in the pharmaceutical and biotech industries for target identification and validation and as secondary screens to reveal potential toxicities or to elucidate a drugs mechanism of action. By using the ImageXpress® Micro XLS System HCS, the complex network of key players controlling proliferation and apoptosis can be reduced to several sentinel markers for analysis. Cell proliferation and apoptosis are two key areas in cell biology and drug discovery research. Understanding the signaling pathways in cell proliferation and apoptosis is important for new therapeutic discovery because the imbalance between these two events is predominant in the progression of many human diseases, including cancer. The DNA binding dye DAPI is used to determine the nuclear size and nuclear morphology as well as cell cycle phases by DNA content. Images together with MetaXpress® analysis results provide a convenient and easy to use solution to high volume image management. In particular, HCS platform is beginning to have an important impact on early drug discovery, basic research in systems cell biology, and is expected to play a role in personalized medicine or revealing off-target drug effects. (author)

  8. Prenatal Screening Using Maternal Markers

    Directory of Open Access Journals (Sweden)

    Howard Cuckle

    2014-05-01

    Full Text Available Maternal markers are widely used to screen for fetal neural tube defects (NTDs, chromosomal abnormalities and cardiac defects. Some are beginning to broaden prenatal screening to include pregnancy complications such as pre-eclampsia. The methods initially developed for NTDs using a single marker have since been built upon to develop high performance multi-maker tests for chromosomal abnormalities. Although cell-free DNA testing is still too expensive to be considered for routine application in public health settings, it can be cost-effective when used in combination with existing multi-maker marker tests. The established screening methods can be readily applied in the first trimester to identify pregnancies at high risk of pre-eclampsia and offer prevention though aspirin treatment. Prenatal screening for fragile X syndrome might be adopted more widely if the test was to be framed as a form of maternal marker screening.

  9. Diabetes screening in the workplace.

    Science.gov (United States)

    Gulley, Tauna; Boggs, Dusta; Mullins, Rebecca; Brock, Emily

    2014-11-01

    The prevalence of diabetes has increased worldwide and the pathophysiological problems associated with diabetes increase the potential for employees' physical disabilities. These complications, including neuropathy, nephropathy, and visual impairment, negatively impact the job performance of employees and compromise workplace safety. Occupational health nurses can provide diabetes screening programs to employees and identify chronic disease risk factors early. This article describes an occupational diabetes screening program at a major corporation in Belize, Central America, defines diabetes, outlines the diabetes teaching plan, and presents the demographics of the participants and results of the screening. Cultural considerations and recommendations for future occupational diabetes screenings are proposed. Copyright 2014, SLACK Incorporated.

  10. Screening on urogenital Chlamydia trachomatis

    Directory of Open Access Journals (Sweden)

    Busse, Reinhard

    2005-12-01

    Full Text Available Introduction: Around 92 million urogenital infections are caused yearly by Chlamydia trachomatis worldwide [1]. The overall incidence of sexually transmitted diseases is increasing, as shown by the increases in the number of reported cases of syphilis and gonorrhea [2]. Chlamydia trachomatis infections are associated with various serious diseases in women, men and newborns, which could be, at least partially, avoided by means of early diagnosis and therapy. The Federal Joint Committee - responsible for decision-making concerning the benefit package of the German Social Health Insurance - has publicly announced the starting of deliberations on the issue of screening for Chlamydia trachomatis. Research Questions: The leading question to be answered is whether screening for Chlamydia trachomatis should be included in the German benefit basket. The aim of this report is to provide a summary of the available evidence concerning the issue of screening for Chlamydia trachomatis. Methods: The summary of published scientific evidence, including HTA reports, systematic reviews, guidelines and primary research is represented. The synthesis follows the structure given by the criteria of Wilson and Jungner [3] for the introduction of screening in a population: relevance of the condition, availability of an adequate test, effectiveness of screening, acceptance of the programme, and economical issues. A literature search was conducted for each aspect of the synthesis and the evidence has been summarised in evidence tables. Results: We identified five HTA reports from three European agencies [4], [5], [6], [7] and one from the USA [8]. In addition, we identified four guidelines from Northamerica [9], [10], [11], [12] and one from Europe [13]. A total of 56 primary research publications were included: relevance of the disease (n=26, availability of test (n=1, effectiveness of screening (n=11, acceptance of the programme (n=11, economical issues (n=7. Discussion

  11. Bacterial contamination of computer touch screens.

    Science.gov (United States)

    Gerba, Charles P; Wuollet, Adam L; Raisanen, Peter; Lopez, Gerardo U

    2016-03-01

    The goal of this study was to determine the occurrence of opportunistic bacterial pathogens on the surfaces of computer touch screens used in hospitals and grocery stores. Opportunistic pathogenic bacteria were isolated on touch screens in hospitals; Clostridium difficile and vancomycin-resistant Enterococcus and in grocery stores; methicillin-resistant Staphylococcus aureus. Enteric bacteria were more common on grocery store touch screens than on hospital computer touch screens. Published by Elsevier Inc.

  12. Impact of Prostatic-specific Antigen Threshold and Screening Interval in Prostate Cancer Screening Outcomes: Comparing the Swedish and Finnish European Randomised Study of Screening for Prostate Cancer Centres.

    Science.gov (United States)

    Saarimäki, Lasse; Hugosson, Jonas; Tammela, Teuvo L; Carlsson, Sigrid; Talala, Kirsi; Auvinen, Anssi

    2017-08-10

    The European Randomised Study of Screening for Prostate Cancer trial has shown a 21% reduction in prostate cancer (PC) mortality with prostate-specific antigen (PSA)-based screening. Sweden used a 2-yr screening interval and showed a larger mortality reduction than Finland with a 4-yr interval and higher PSA cut-off. To evaluate the impact of screening interval and PSA cut-off on PC detection and mortality. We analysed the core age groups (55-69 yr at entry) of the Finnish (N=31 866) and Swedish (N=5901) screening arms at 13 yr and 16 yr of follow-up. Sweden used a screening interval of 2 yr and a PSA cut-off of 3.0ng/ml, while in Finland the screening interval was 4 yr and the PSA cut-off 4.0ng/ml (or PSA 3.0-3.9ng/ml with free PSAprostate-specific antigen threshold of 3ng/ml versus 4ng/ml or a screening interval of 2 yr instead of 4 yr is unlikely to explain the larger mortality reduction achieved in Sweden compared with Finland. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  13. Touch screens go optical

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Jakobsen, Michael Linde; Pedersen, Henrik Chresten

    2012-01-01

    A simple optical implementation of a touch screen is made possible by disrupting the total internal reflection in a 2D waveguide.......A simple optical implementation of a touch screen is made possible by disrupting the total internal reflection in a 2D waveguide....

  14. Screening for chlamydial infection.

    Science.gov (United States)

    Nelson, H D; Helfand, M

    2001-04-01

    To examine data on the effectiveness of screening for chlamydial infection by a physician or other health care professional. Specifically, we examine the evidence that early treatment of chlamydial infection improves health outcomes, as well as evidence of the effectiveness of screening strategies in nonpregnant women, pregnant women, and men, and the accuracy of tests used for screening. This review updates the literature since the last recommendation of the U.S. Preventive Services Task Force published in 1996. We searched the topic of chlamydia in the MEDLINE, HealthSTAR, and Cochrane Library databases from January 1994 to July 2000, supplemented by reference lists of relevant articles and from experts in the field. Articles published prior to 1994 and research abstracts were cited if particularly important to the key questions or to the interpretation of included articles. A single reader reviewed all English abstracts. Articles were selected for full review if they were about Chlamydia trachomatis genitourinary infections in nonpregnant women, pregnant women, or men and were relevant to key questions in the analytic framework. Investigators read the full-text version of the retrieved articles and applied additional eligibility criteria. For all topics, we excluded articles if they did not provide sufficient information to determine the methods for selecting subjects and for analyzing data. We systematically reviewed three types of studies about screening in nonpregnant women that relate to three key questions: (1) studies about the effectiveness of screening programs in reducing prevalence rates of infection, (2) studies about risk factors for chlamydial infection in women, and (3) studies about chlamydial screening tests in women. Our search found too few studies on pregnant women to systematically review, although pertinent studies are described. We systematically reviewed two types of studies about screening in men: (1) studies about prevalence rates and

  15. Luminescence studies on phosphor screens

    International Nuclear Information System (INIS)

    Panayiotakis, G.; Nomikos, C.; Bakas, A.; Proimos, B.

    1994-01-01

    We report our results on x-ray phosphor screens prepared of some new materials focusing attention on their efficiency under fluoroscopy conditions, on optimization conditions and on comparisons among the various materials. All data are presented in absolute values. A theoretical model is presented, that takes into account the granular structure of the screens, permitting the explanation and prediction of the luminescence properties of the screens. (authors)

  16. Computer Screen Use Detection Using Smart Eyeglasses

    Directory of Open Access Journals (Sweden)

    Florian Wahl

    2017-05-01

    Full Text Available Screen use can influence the circadian phase and cause eye strain. Smart eyeglasses with an integrated color light sensor can detect screen use. We present a screen use detection approach based on a light sensor embedded into the bridge of smart eyeglasses. By calculating the light intensity at the user’s eyes for different screens and content types, we found only computer screens to have a significant impact on the circadian phase. Our screen use detection is based on ratios between color channels and used a linear support vector machine to detect screen use. We validated our detection approach in three studies. A test bench was built to detect screen use under different ambient light sources and intensities in a controlled environment. In a lab study, we evaluated recognition performance for different ambient light intensities. By using participant-independent models, we achieved an ROC AUC above 0.9 for ambient light intensities below 200 lx. In a study of typical ADLs, screen use was detected with an average ROC AUC of 0.83 assuming screen use for 30% of the time.

  17. Breast Cancer Challenges and Screening in China: Lessons From Current Registry Data and Population Screening Studies.

    Science.gov (United States)

    Song, Qing-Kun; Wang, Xiao-Li; Zhou, Xin-Na; Yang, Hua-Bing; Li, Yu-Chen; Wu, Jiang-Ping; Ren, Jun; Lyerly, Herbert Kim

    2015-07-01

    As one of its responses to the increasing global burden of breast cancer (BC), China has deployed a national registration and BC screening campaign. The present report describes these programs and the initial results of these national BC control strategies, highlighting the challenges to be considered. The primary BC incidence and prevalence data were obtained from the Chinese National Central Cancer Registry. MapInfo software was used to map the geographic distribution and variation. The time trends were estimated by the annual percentage of change from 2003 to 2009. The description of the screening plans and preliminary results were provided by the Ministry of Health. Chinese cancer registries were primarily developed and activated in the East and Coastal regions of China, with only 12.5% of the registries located in West China. Geographic variation was noted, with the incidence of BC higher in North China than in South China and in urban areas compared with rural areas. Of great interest, these registries reported that the overall BC incidence has been increasing in China, with an earlier age of onset compared with Western countries and a peak incidence rate at age 50. In response to this increasing incidence and early age of onset, BC screening programs assessed 1.46 million women aged 35-59 years, using clinical breast examinations and ultrasound as primary screening tools between 2009 and 2011. The diagnostic rate for this screening program was only 48.0/10(5) with 440 cases of early stage BC. Early stage BC was detected in nearly 70% of screened patients. Subsequently, a second-generation screening program was conducted that included older women aged 35-64 years and an additional 6 million women were screened. The cancer registration system in China has been uneven, with a greater focus on East rather than West China. The data from these registries demonstrate regional variation, an increasing BC incidence, and an early age of onset. The 2009 to 2011 BC

  18. Breast cancer screening: ''reassuring'' the worried well?

    DEFF Research Database (Denmark)

    Brodersen, John; Siersma, Volkert; Ryle, Mette

    2011-01-01

    of women offered screening compared to a population of women not offered screening for breast cancer. METHODS: One thousand women, aged 50-69 years, were randomly drawn from the Danish Civil Registration System to receive part I of the questionnaire Consequences of Screening in Breast Cancer (COS-BC1......): the sample consisted of 500 women living in a geographical area where screening mammography had been offered for more than 10 years and 500 women living in an area where the public health authorities had never invited women to breast cancer screening. RESULTS: A total of 759 women returned the questionnaire....... Those living in areas where screening was not offered reported more negative psychosocial aspects compared to women living in areas where screening was offered. CONCLUSIONS: The results indicate that women tend to perceive breast cancer screening as a reassuring preventive initiative. Alternatively...

  19. Early Dementia Screening

    Directory of Open Access Journals (Sweden)

    Peter K. Panegyres

    2016-01-01

    Full Text Available As the population of the world increases, there will be larger numbers of people with dementia and an emerging need for prompt diagnosis and treatment. Early dementia screening is the process by which a patient who might be in the prodromal phases of a dementing illness is determined as having, or not having, the hallmarks of a neurodegenerative condition. The concepts of mild cognitive impairment, or mild neurocognitive disorder, are useful in analyzing the patient in the prodromal phase of a dementing disease; however, the transformation to dementia may be as low as 10% per annum. The search for early dementia requires a comprehensive clinical evaluation, cognitive assessment, determination of functional status, corroborative history and imaging (including MRI, FDG-PET and maybe amyloid PET, cerebrospinal fluid (CSF examination assaying Aβ1–42, T-τ and P-τ might also be helpful. Primary care physicians are fundamental in the screening process and are vital in initiating specialist investigation and treatment. Early dementia screening is especially important in an age where there is a search for disease modifying therapies, where there is mounting evidence that treatment, if given early, might influence the natural history—hence the need for cost-effective screening measures for early dementia.

  20. Screening for colorectal cancer: what fits best?

    LENUS (Irish Health Repository)

    Lee, Chun Seng

    2012-06-01

    Colorectal cancer (CRC) screening has been shown to be effective in reducing CRC incidence and mortality. There are currently a number of screening modalities available for implementation into a population-based CRC screening program. Each screening method offers different strengths but also possesses its own limitations as a population-based screening strategy. We review the current evidence base for accepted CRC screening tools and evaluate their merits alongside their challenges in fulfilling their role in the detection of CRC. We also aim to provide an outlook on the demands of a low-risk population-based CRC screening program with a view to providing insight as to which modality would best suit current and future needs.

  1. Mammography screening: A major issue in medicine.

    Science.gov (United States)

    Autier, Philippe; Boniol, Mathieu

    2018-02-01

    Breast cancer mortality is declining in most high-income countries. The role of mammography screening in these declines is much debated. Screening impacts cancer mortality through decreasing the incidence of number of advanced cancers with poor prognosis, while therapies and patient management impact cancer mortality through decreasing the fatality of cancers. The effectiveness of cancer screening is the ability of a screening method to curb the incidence of advanced cancers in populations. Methods for evaluating cancer screening effectiveness are based on the monitoring of age-adjusted incidence rates of advanced cancers that should decrease after the introduction of screening. Likewise, cancer-specific mortality rates should decline more rapidly in areas with screening than in areas without or with lower levels of screening but where patient management is similar. These two criteria have provided evidence that screening for colorectal and cervical cancer contributes to decreasing the mortality associated with these two cancers. In contrast, screening for neuroblastoma in children was discontinued in the early 2000s because these two criteria were not met. In addition, overdiagnosis - i.e. the detection of non-progressing occult neuroblastoma that would not have been life-threatening during the subject's lifetime - is a major undesirable consequence of screening. Accumulating epidemiological data show that in populations where mammography screening has been widespread for a long time, there has been no or only a modest decline in the incidence of advanced cancers, including that of de novo metastatic (stage IV) cancers at diagnosis. Moreover, breast cancer mortality reductions are similar in areas with early introduction and high penetration of screening and in areas with late introduction and low penetration of screening. Overdiagnosis is commonplace, representing 20% or more of all breast cancers among women invited to screening and 30-50% of screen

  2. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    Science.gov (United States)

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with

  3. Transposon activation mutagenesis as a screening tool for identifying resistance to cancer therapeutics

    International Nuclear Information System (INIS)

    Chen, Li; Schmidt, Emmett V; Stuart, Lynda; Ohsumi, Toshiro K; Burgess, Shawn; Varshney, Gaurav K; Dastur, Anahita; Borowsky, Mark; Benes, Cyril; Lacy-Hulbert, Adam

    2013-01-01

    The development of resistance to chemotherapies represents a significant barrier to successful cancer treatment. Resistance mechanisms are complex, can involve diverse and often unexpected cellular processes, and can vary with both the underlying genetic lesion and the origin or type of tumor. For these reasons developing experimental strategies that could be used to understand, identify and predict mechanisms of resistance in different malignant cells would be a major advance. Here we describe a gain-of-function forward genetic approach for identifying mechanisms of resistance. This approach uses a modified piggyBac transposon to generate libraries of mutagenized cells, each containing transposon insertions that randomly activate nearby gene expression. Genes of interest are identified using next-gen high-throughput sequencing and barcode multiplexing is used to reduce experimental cost. Using this approach we successfully identify genes involved in paclitaxel resistance in a variety of cancer cell lines, including the multidrug transporter ABCB1, a previously identified major paclitaxel resistance gene. Analysis of co-occurring transposons integration sites in single cell clone allows for the identification of genes that might act cooperatively to produce drug resistance a level of information not accessible using RNAi or ORF expression screening approaches. We have developed a powerful pipeline to systematically discover drug resistance in mammalian cells in vitro. This cost-effective approach can be readily applied to different cell lines, to identify canonical or context specific resistance mechanisms. Its ability to probe complex genetic context and non-coding genomic elements as well as cooperative resistance events makes it a good complement to RNAi or ORF expression based screens

  4. Population-based screening versus case detection.

    Directory of Open Access Journals (Sweden)

    Thomas Ravi

    2002-01-01

    Full Text Available India has a large burden of blindness and population-based screening is a strategy commonly employed to detect disease and prevent morbidity. However, not all diseases are amenable to screening. This communication examines the issue of "population-based screening" versus "case detection" in the Indian scenario. Using the example of glaucoma, it demonstrates that given the poor infrastructure, for a "rare" disease, case detection is more effective than population-based screening.

  5. High-Throughput Flow Cytometry Screening Reveals a Role for Junctional Adhesion Molecule A as a Cancer Stem Cell Maintenance Factor

    Directory of Open Access Journals (Sweden)

    Justin D. Lathia

    2014-01-01

    Full Text Available Stem cells reside in niches that regulate the balance between self-renewal and differentiation. The identity of a stem cell is linked with the ability to interact with its niche through adhesion mechanisms. To identify targets that disrupt cancer stem cell (CSC adhesion, we performed a flow cytometry screen on patient-derived glioblastoma (GBM cells and identified junctional adhesion molecule A (JAM-A as a CSC adhesion mechanism essential for self-renewal and tumor growth. JAM-A was dispensable for normal neural stem/progenitor cell (NPC function, and JAM-A expression was reduced in normal brain versus GBM. Targeting JAM-A compromised the self-renewal of CSCs. JAM-A expression negatively correlated to GBM patient prognosis. Our results demonstrate that GBM-targeting strategies can be identified through screening adhesion receptors and JAM-A represents a mechanism for niche-driven CSC maintenance.

  6. Colorectal Cancer Screening: An Educational Intervention for Nurse Practitioners to Increase Screening Awareness and Participation
.

    Science.gov (United States)

    Slyne, Tai C; Gautam, Ramraj; King, Valerie

    2017-10-01

    Colorectal cancer screening aims to detect colorectal cancer at an early stage, when treatment is more likely to be curative. Lack of participation in such screening is a major issue in primary care practices, where nurse practitioners (NPs) often provide care. This study aimed to determine whether an educational intervention for NPs would increase their awareness of, and increase patients' participation in, colorectal cancer screening. 
.

  7. Luminescence studies on phosphor screens

    Energy Technology Data Exchange (ETDEWEB)

    Panayiotakis, G; Nomikos, C; Bakas, A; Proimos, B [Medical Physics Department, University of Patras, 265 00 Patras, Greece (Greece)

    1994-12-31

    We report our results on x-ray phosphor screens prepared of some new materials focusing attention on their efficiency under fluoroscopy conditions, on optimization conditions and on comparisons among the various materials. All data are presented in absolute values. A theoretical model is presented, that takes into account the granular structure of the screens, permitting the explanation and prediction of the luminescence properties of the screens. (authors). 12 refs, 3 figs.

  8. Lectures on quantum mechanics

    International Nuclear Information System (INIS)

    Weinberg, Steven

    2015-01-01

    Quantum mechanics represents the central revolution of modern natural science and reaches in its importance farely beyond physics. Neither chemistry nor biology on the molecular scale would be understandable without it. Modern information technology from the laptop over the mobile telephone and the flat screen until the supercomputer would be unthinkable without quantum-mechanical effects. It desribes the world on the atomic and subatomic scale and is by this the starting point of our modern worldview. The Nobel-prize carrier Steven Weinberg has done ever among others by his theory of the unification of the weak and the electromagnetic interaction one of the most important contributions to this revolution. In this book he reproduces his personal view of quantum mechanics, which captivates by its strictly logic construction, precise linguistic representation, and mathematical clearness and completeness. This book appeals to studyings of natural sciences, especially of physics. Accompanied is the test by exercise problems, which allow the studying to apply immediately the knowledge, but also test their understanding. Because of its precision and clearness ''Lectures on Quantum Mechanics'' by Weinberg is also essentially suited for the self-study.

  9. A CRISPR-Based Screen Identifies Genes Essential for West-Nile-Virus-Induced Cell Death.

    Science.gov (United States)

    Ma, Hongming; Dang, Ying; Wu, Yonggan; Jia, Gengxiang; Anaya, Edgar; Zhang, Junli; Abraham, Sojan; Choi, Jang-Gi; Shi, Guojun; Qi, Ling; Manjunath, N; Wu, Haoquan

    2015-07-28

    West Nile virus (WNV) causes an acute neurological infection attended by massive neuronal cell death. However, the mechanism(s) behind the virus-induced cell death is poorly understood. Using a library containing 77,406 sgRNAs targeting 20,121 genes, we performed a genome-wide screen followed by a second screen with a sub-library. Among the genes identified, seven genes, EMC2, EMC3, SEL1L, DERL2, UBE2G2, UBE2J1, and HRD1, stood out as having the strongest phenotype, whose knockout conferred strong protection against WNV-induced cell death with two different WNV strains and in three cell lines. Interestingly, knockout of these genes did not block WNV replication. Thus, these appear to be essential genes that link WNV replication to downstream cell death pathway(s). In addition, the fact that all of these genes belong to the ER-associated protein degradation (ERAD) pathway suggests that this might be the primary driver of WNV-induced cell death. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Antiviral Screening of Multiple Compounds against Ebola Virus.

    Science.gov (United States)

    Dowall, Stuart D; Bewley, Kevin; Watson, Robert J; Vasan, Seshadri S; Ghosh, Chandradhish; Konai, Mohini M; Gausdal, Gro; Lorens, James B; Long, Jason; Barclay, Wendy; Garcia-Dorival, Isabel; Hiscox, Julian; Bosworth, Andrew; Taylor, Irene; Easterbrook, Linda; Pitman, James; Summers, Sian; Chan-Pensley, Jenny; Funnell, Simon; Vipond, Julia; Charlton, Sue; Haldar, Jayanta; Hewson, Roger; Carroll, Miles W

    2016-10-27

    In light of the recent outbreak of Ebola virus (EBOV) disease in West Africa, there have been renewed efforts to search for effective antiviral countermeasures. A range of compounds currently available with broad antimicrobial activity have been tested for activity against EBOV. Using live EBOV, eighteen candidate compounds were screened for antiviral activity in vitro. The compounds were selected on a rational basis because their mechanisms of action suggested that they had the potential to disrupt EBOV entry, replication or exit from cells or because they had displayed some antiviral activity against EBOV in previous tests. Nine compounds caused no reduction in viral replication despite cells remaining healthy, so they were excluded from further analysis (zidovudine; didanosine; stavudine; abacavir sulphate; entecavir; JB1a; Aimspro; celgosivir; and castanospermine). A second screen of the remaining compounds and the feasibility of appropriateness for in vivo testing removed six further compounds (ouabain; omeprazole; esomeprazole; Gleevec; D-LANA-14; and Tasigna). The three most promising compounds (17-DMAG; BGB324; and NCK-8) were further screened for in vivo activity in the guinea pig model of EBOV disease. Two of the compounds, BGB324 and NCK-8, showed some effect against lethal infection in vivo at the concentrations tested, which warrants further investigation. Further, these data add to the body of knowledge on the antiviral activities of multiple compounds against EBOV and indicate that the scientific community should invest more effort into the development of novel and specific antiviral compounds to treat Ebola virus disease.

  11. Antiviral Screening of Multiple Compounds against Ebola Virus

    Directory of Open Access Journals (Sweden)

    Stuart D. Dowall

    2016-10-01

    Full Text Available In light of the recent outbreak of Ebola virus (EBOV disease in West Africa, there have been renewed efforts to search for effective antiviral countermeasures. A range of compounds currently available with broad antimicrobial activity have been tested for activity against EBOV. Using live EBOV, eighteen candidate compounds were screened for antiviral activity in vitro. The compounds were selected on a rational basis because their mechanisms of action suggested that they had the potential to disrupt EBOV entry, replication or exit from cells or because they had displayed some antiviral activity against EBOV in previous tests. Nine compounds caused no reduction in viral replication despite cells remaining healthy, so they were excluded from further analysis (zidovudine; didanosine; stavudine; abacavir sulphate; entecavir; JB1a; Aimspro; celgosivir; and castanospermine. A second screen of the remaining compounds and the feasibility of appropriateness for in vivo testing removed six further compounds (ouabain; omeprazole; esomeprazole; Gleevec; D-LANA-14; and Tasigna. The three most promising compounds (17-DMAG; BGB324; and NCK-8 were further screened for in vivo activity in the guinea pig model of EBOV disease. Two of the compounds, BGB324 and NCK-8, showed some effect against lethal infection in vivo at the concentrations tested, which warrants further investigation. Further, these data add to the body of knowledge on the antiviral activities of multiple compounds against EBOV and indicate that the scientific community should invest more effort into the development of novel and specific antiviral compounds to treat Ebola virus disease.

  12. The impact of radiologists' expertise on screen results decisions in a CT lung cancer screening trial

    Energy Technology Data Exchange (ETDEWEB)

    Heuvelmans, Marjolein A.; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Groningen (Netherlands); University of Groningen / University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Groningen (Netherlands); Jong, Pim A. de; Mali, Willem P. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Groen, Harry J.M. [University of Groningen, University Medical Center Groningen, Department of Pulmonology, Groningen (Netherlands)

    2014-11-04

    To evaluate the impact of radiological expertise on screen result decisions in a CT lung cancer screening trial. In the NELSON lung cancer screening trial, the baseline CT result was based on the largest lung nodule's volume. The protocol allowed radiologists to manually adjust screen results in cases of high suspicion of benign or malignant nodule nature. Participants whose baseline CT result was based on a solid or part-solid nodule were included in this study. Adjustments by radiologists at baseline were evaluated. Histology was the reference for diagnosis or to confirm benignity and stability on subsequent CT examinations. A total of 3,318 participants (2,796 male, median age 58.0 years) were included. In 195 participants (5.9 %) the initial baseline screen result was adjusted by the radiologist. Adjustment was downwards from positive or indeterminate to negative in two and 119 participants, respectively, and from positive to indeterminate in 65 participants. None of these nodules turned out to be malignant. In 9/195 participants (4.6 %) the screen result was adjusted upwards from negative to indeterminate or indeterminate to positive; two nodules were malignant. In one in 20 cases of baseline lung cancer screening, nodules were reclassified by the radiologist, leading to a reduction of false-positive screen results. (orig.)

  13. Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.

    Science.gov (United States)

    Li, Jun; Zhao, Guixiang; Hall, Ingrid J

    2015-08-01

    For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (ptesting with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.

  14. Increasing Cervical Cancer Screening in Underserved Populations.

    Science.gov (United States)

    Dorsainvil, Merlyn A

    The incidence of cervical cancer has declined dramatically due to Papanicolaou smear testing. However, some minority populations continue to suffer with high incidences and/or death rates of cervical cancer, due to lack of screening. This article updates on cervical cancer screening and prevention and discusses cultural impacts on screening. Knowledge deficits disproportionately affect ethnic minority groups and contribute to cancer incidence, whereas lack of healthcare coverage and low socioeconomic status contribute to screening disparities. Although minority women have cultural beliefs and practices that influence screening, recommendation and/or education from a provider often lead to screening.

  15. Some legal aspects of genetic screening.

    Science.gov (United States)

    Abbing, H R

    2003-01-01

    Screening activities in health care are not always useful and sometimes harmful. The mere offer of a screening test puts the individual's autonomy under constraint. With genetic (predictive and risk assessment) tests, the right to free, informed consent and to protection of privacy and medical confidentiality is even more warranted. Screening evokes many questions from the perspective of the right to health care as well as (in particular with genetic screening) from the perspective of respect for individual human rights. Fear of liability puts pressure on professional restraint not to offer every screening test available. States have to take legislative measures for guaranteeing that only those screening activities become available that can significantly contribute to individual and public health. They also should consider additional rules for protecting individual rights where those that are generally accepted in the "ordinary" medical setting (the individual patient-doctor relationship), offer insufficient protection.

  16. Interval lung cancer after a negative CT screening examination: CT findings and outcomes in National Lung Screening Trial participants

    International Nuclear Information System (INIS)

    Gierada, David S.; Pinsky, Paul F.; Duan, Fenghai; Garg, Kavita; Hart, Eric M.; Kazerooni, Ella A.; Nath, Hrudaya; Watts, Jubal R.; Aberle, Denise R.

    2017-01-01

    This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. (orig.)

  17. Interval lung cancer after a negative CT screening examination: CT findings and outcomes in National Lung Screening Trial participants

    Energy Technology Data Exchange (ETDEWEB)

    Gierada, David S. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, Box 8131, St. Louis, MO (United States); Pinsky, Paul F. [National Cancer Institute, Bethesda, MD (United States); Duan, Fenghai [Brown University School of Public Health, Department of Biostatistics and Center for Statistical Sciences, Providence, RI (United States); Garg, Kavita [University of Colorado School of Medicine, Mail Stop F726, Box 6510, Aurora, CO (United States); Hart, Eric M. [Northwestern University, Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Kazerooni, Ella A. [University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Nath, Hrudaya; Watts, Jubal R. [University of Alabama at Birmingham School of Medicine, Department of Radiology-JTN370, Birmingham, AL (United States); Aberle, Denise R. [David Geffen School of Medicine at UCLA, Department of Radiological Sciences, Los Angeles, CA (United States)

    2017-08-15

    This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. (orig.)

  18. Nutritional Risk Screening 2002, Short Nutritional Assessment Questionnaire, Malnutrition Screening Tool, and Malnutrition Universal Screening Tool Are Good Predictors of Nutrition Risk in an Emergency Service.

    Science.gov (United States)

    Rabito, Estela Iraci; Marcadenti, Aline; da Silva Fink, Jaqueline; Figueira, Luciane; Silva, Flávia Moraes

    2017-08-01

    There is an international consensus that nutrition screening be performed at the hospital; however, there is no "best tool" for screening of malnutrition risk in hospitalized patients. To evaluate (1) the accuracy of the MUST (Malnutrition Universal Screening Tool), MST (Malnutrition Screening Tool), and SNAQ (Short Nutritional Assessment Questionnaire) in comparison with the NRS-2002 (Nutritional Risk Screening 2002) to identify patients at risk of malnutrition and (2) the ability of these nutrition screening tools to predict morbidity and mortality. A specific questionnaire was administered to complete the 4 screening tools. Outcomes measures included length of hospital stay, transfer to the intensive care unit, presence of infection, and incidence of death. A total of 752 patients were included. The nutrition risk was 29.3%, 37.1%, 33.6%, and 31.3% according to the NRS-2002, MUST, MST, and SNAQ, respectively. All screening tools showed satisfactory performance to identify patients at nutrition risk (area under the receiver operating characteristic curve between 0.765-0.808). Patients at nutrition risk showed higher risk of very long length of hospital stay as compared with those not at nutrition risk, independent of the tool applied (relative risk, 1.35-1.78). Increased risk of mortality (2.34 times) was detected by the MUST. The MUST, MST, and SNAQ share similar accuracy to the NRS-2002 in identifying risk of malnutrition, and all instruments were positively associated with very long hospital stay. In clinical practice, the 4 tools could be applied, and the choice for one of them should be made per the particularities of the service.

  19. Screening Sex: revelando e dissimulando o sexo Screening Sex

    Directory of Open Access Journals (Sweden)

    Linda Williams

    2012-06-01

    Full Text Available Neste texto, procura-se contar a história da exibição do sexo em filmes majoritariamente produzidos nos Estados Unidos no período de quase um século. Ao se perguntar quando, porque e como os Estados Unidos se transformaram de uma cultura que não exibia o sexo em uma que o exibe, a autora insiste no duplo significado do verbo screen (tanto como uma revelação quanto uma dissimulação. Exibir é revelar em uma tela. Mas um segundo e igualmente importante significado, como diz o dicionário é "proteger ou esconder atrás de uma tela". Os filmes tanto revelam como escondem. O artigo analisa a forma como mudanças sociais ocorridas nos Estados Unidos, como, por exemplo, a Revolução sexual dos anos 60 e novas visões a respeito da sexualidade, possibilitaram novas maneiras de representação do sexo no cinema, reorganizando a relação entre o público e o privado. O artigo se pergunta também sobre como nossos corpos e sentidos reagem ao encontro com o sexo na tela, introduzindo a ideia de "saber carnal" (carnal knowledge.In this paper, we try to tell the history of the exhibition of sex in movies mainly produced in the United States in almost a century. Asking when, why and how the United States became - from a culture that did not exhibit sex - into a culture that exhibits it, the author insists in the double sense of the verb to screen (as both a revelation and a dissimulation. To exhibit is to reveal in a screen. But another, and important, sense, as says the dictionary, is "to protect or hide behind a screen". Movies show as well as they reveal. The paper analyzes the way social change in the United States, for example the sexual revolution of the sixties and new views on sexuality allowed new ways of representing sex in the movies, creating a new relation between public and private. The paper also asks how our bodies and senses react to sex in the screen, introducing the idea of "carnal knowledge".

  20. Women's opinions about attending for breast cancer screening: Stability of cognitive determinants during three rounds of screening.

    NARCIS (Netherlands)

    Drossaert, Constance H.C.; Boer, Hendrik; Seydel, E.R.

    2005-01-01

    Examines women's opinions about attending breast cancer screening. Stability of beliefs and intentions towards repeat attendance at breast cancer screening; Assessment of whether cognitions changed in the course of the programme; Increase of attendance in subsequent rounds of breast cancer screening

  1. Application of microarray and functional-based screening methods for the detection of antimicrobial resistance genes in the microbiomes of healthy humans.

    Directory of Open Access Journals (Sweden)

    Roderick M Card

    Full Text Available The aim of this study was to screen for the presence of antimicrobial resistance genes within the saliva and faecal microbiomes of healthy adult human volunteers from five European countries. Two non-culture based approaches were employed to obviate potential bias associated with difficult to culture members of the microbiota. In a gene target-based approach, a microarray was employed to screen for the presence of over 70 clinically important resistance genes in the saliva and faecal microbiomes. A total of 14 different resistance genes were detected encoding resistances to six antibiotic classes (aminoglycosides, β-lactams, macrolides, sulphonamides, tetracyclines and trimethoprim. The most commonly detected genes were erm(B, blaTEM, and sul2. In a functional-based approach, DNA prepared from pooled saliva samples was cloned into Escherichia coli and screened for expression of resistance to ampicillin or sulphonamide, two of the most common resistances found by array. The functional ampicillin resistance screen recovered genes encoding components of a predicted AcrRAB efflux pump. In the functional sulphonamide resistance screen, folP genes were recovered encoding mutant dihydropteroate synthase, the target of sulphonamide action. The genes recovered from the functional screens were from the chromosomes of commensal species that are opportunistically pathogenic and capable of exchanging DNA with related pathogenic species. Genes identified by microarray were not recovered in the activity-based screen, indicating that these two methods can be complementary in facilitating the identification of a range of resistance mechanisms present within the human microbiome. It also provides further evidence of the diverse reservoir of resistance mechanisms present in bacterial populations in the human gut and saliva. In future the methods described in this study can be used to monitor changes in the resistome in response to antibiotic therapy.

  2. Neonatal cystic fibrosis screening test

    Science.gov (United States)

    Cystic fibrosis screening - neonatal; Immunoreactive trypsinogen; IRT test; CF - screening ... Cystic fibrosis is a disease passed down through families. CF causes thick, sticky mucus to build up in ...

  3. A New In Vivo Screening Paradigm to Accelerate Antimalarial Drug Discovery

    Science.gov (United States)

    Jiménez-Díaz, María Belén; Viera, Sara; Ibáñez, Javier; Mulet, Teresa; Magán-Marchal, Noemí; Garuti, Helen; Gómez, Vanessa; Cortés-Gil, Lorena; Martínez, Antonio; Ferrer, Santiago; Fraile, María Teresa; Calderón, Félix; Fernández, Esther; Shultz, Leonard D.; Leroy, Didier; Wilson, David M.; García-Bustos, José Francisco; Gamo, Francisco Javier; Angulo-Barturen, Iñigo

    2013-01-01

    The emergence of resistance to available antimalarials requires the urgent development of new medicines. The recent disclosure of several thousand compounds active in vitro against the erythrocyte stage of Plasmodium falciparum has been a major breakthrough, though converting these hits into new medicines challenges current strategies. A new in vivo screening concept was evaluated as a strategy to increase the speed and efficiency of drug discovery projects in malaria. The new in vivo screening concept was developed based on human disease parameters, i.e. parasitemia in the peripheral blood of patients on hospital admission and parasite reduction ratio (PRR), which were allometrically down-scaled into P. berghei-infected mice. Mice with an initial parasitemia (P0) of 1.5% were treated orally for two consecutive days and parasitemia measured 24 h after the second dose. The assay was optimized for detection of compounds able to stop parasite replication (PRR = 1) or induce parasite clearance (PRR >1) with statistical power >99% using only two mice per experimental group. In the P. berghei in vivo screening assay, the PRR of a set of eleven antimalarials with different mechanisms of action correlated with human-equivalent data. Subsequently, 590 compounds from the Tres Cantos Antimalarial Set with activity in vitro against P. falciparum were tested at 50 mg/kg (orally) in an assay format that allowed the evaluation of hundreds of compounds per month. The rate of compounds with detectable efficacy was 11.2% and about one third of active compounds showed in vivo efficacy comparable with the most potent antimalarials used clinically. High-throughput, high-content in vivo screening could rapidly select new compounds, dramatically speeding up the discovery of new antimalarial medicines. A global multilateral collaborative project aimed at screening the significant chemical diversity within the antimalarial in vitro hits described in the literature is a feasible task

  4. A new in vivo screening paradigm to accelerate antimalarial drug discovery.

    Directory of Open Access Journals (Sweden)

    María Belén Jiménez-Díaz

    Full Text Available The emergence of resistance to available antimalarials requires the urgent development of new medicines. The recent disclosure of several thousand compounds active in vitro against the erythrocyte stage of Plasmodium falciparum has been a major breakthrough, though converting these hits into new medicines challenges current strategies. A new in vivo screening concept was evaluated as a strategy to increase the speed and efficiency of drug discovery projects in malaria. The new in vivo screening concept was developed based on human disease parameters, i.e. parasitemia in the peripheral blood of patients on hospital admission and parasite reduction ratio (PRR, which were allometrically down-scaled into P. berghei-infected mice. Mice with an initial parasitemia (P0 of 1.5% were treated orally for two consecutive days and parasitemia measured 24 h after the second dose. The assay was optimized for detection of compounds able to stop parasite replication (PRR = 1 or induce parasite clearance (PRR >1 with statistical power >99% using only two mice per experimental group. In the P. berghei in vivo screening assay, the PRR of a set of eleven antimalarials with different mechanisms of action correlated with human-equivalent data. Subsequently, 590 compounds from the Tres Cantos Antimalarial Set with activity in vitro against P. falciparum were tested at 50 mg/kg (orally in an assay format that allowed the evaluation of hundreds of compounds per month. The rate of compounds with detectable efficacy was 11.2% and about one third of active compounds showed in vivo efficacy comparable with the most potent antimalarials used clinically. High-throughput, high-content in vivo screening could rapidly select new compounds, dramatically speeding up the discovery of new antimalarial medicines. A global multilateral collaborative project aimed at screening the significant chemical diversity within the antimalarial in vitro hits described in the literature is a

  5. EIA screening in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Eskild Holm; Christensen, Per; Kørnøv, Lone

    2005-01-01

    The article points out that EIA screening is effectively a regulatory instrument and it can be a cost-effective instrument with environmental benefits.......The article points out that EIA screening is effectively a regulatory instrument and it can be a cost-effective instrument with environmental benefits....

  6. Valuing Equal Protection in Aviation Security Screening.

    Science.gov (United States)

    Nguyen, Kenneth D; Rosoff, Heather; John, Richard S

    2017-12-01

    The growing number of anti-terrorism policies has elevated public concerns about discrimination. Within the context of airport security screening, the current study examines how American travelers value the principle of equal protection by quantifying the "equity premium" that they are willing to sacrifice to avoid screening procedures that result in differential treatments. In addition, we applied the notion of procedural justice to explore the effect of alternative selective screening procedures on the value of equal protection. Two-hundred and twenty-two respondents were randomly assigned to one of three selective screening procedures: (1) randomly, (2) using behavioral indicators, or (3) based on demographic characteristics. They were asked to choose between airlines using either an equal or a discriminatory screening procedure. While the former requires all passengers to be screened in the same manner, the latter mandates all passengers undergo a quick primary screening and, in addition, some passengers are selected for a secondary screening based on a predetermined selection criterion. Equity premiums were quantified in terms of monetary cost, wait time, convenience, and safety compromise. Results show that equity premiums varied greatly across respondents, with many indicating little willingness to sacrifice to avoid inequitable screening, and a smaller minority willing to sacrifice anything to avoid the discriminatory screening. The selective screening manipulation was effective in that equity premiums were greater under selection by demographic characteristics compared to the other two procedures. © 2017 Society for Risk Analysis.

  7. Recommendations for newborn screening for galactokinase deficiency: A systematic review and evaluation of Dutch newborn screening data.

    Science.gov (United States)

    Stroek, Kevin; Bouva, Marelle J; Schielen, Peter C J I; Vaz, Frédéric M; Heijboer, Annemieke C; de Jonge, Robert; Boelen, Anita; Bosch, Annet M

    2018-03-21

    Galactokinase (GALK) deficiency causes cataract leading to severe developmental consequences unless treated early. Because of the easy prevention and rapid reversibility of cataract with treatment, the Dutch Health Council advised to include GALK deficiency in the Dutch newborn screening program. The aim of this study is to establish the optimal screening method and cut-off value (COV) for GALK deficiency screening by performing a systematic review of the literature of screening strategies and total galactose (TGAL) values and by evaluating TGAL values in the first week of life in a cohort of screened newborns in the Netherlands. Systematic literature search strategies in OVID MEDLINE and OVID EMBASE were developed and study selection, data collection and analyses were performed by two independent investigators. A range of TGAL values measured by the Quantase Neonatal Total Galactose screening assay in a cohort of Dutch newborns in 2007 was evaluated. Eight publications were included in the systematic review. All four studies describing screening strategies used TGAL as the primary screening marker combined with galactose-1-phosphate uridyltransferase (GALT) measurement that is used for classical galactosemia screening. TGAL COVs of 2200 μmol/L, 1665 μmol/L and 1110 μmol/L blood resulted in positive predictive values (PPV) of 100%, 82% and 10% respectively. TGAL values measured in the newborn period were reported for 39 GALK deficiency patients with individual values ranging from 3963 to 8159 μmol/L blood and 2 group values with mean 8892 μmol/L blood (SD ± 5243) and 4856 μmol/L blood (SD ± 461). Dutch newborn screening data of 72,786 newborns from 2007 provided a median TGAL value of 110 μmol/L blood with a range of 30-2431 μmol/L blood. Based on TGAL values measured in GALK deficiency patients reported in the literature and TGAL measurements in the Dutch cohort by newborn screening we suggest to perform the GALK screening with

  8. CLAD DEGRADATION - FEPS SCREENING ARGUMENTS

    International Nuclear Information System (INIS)

    R. Schreiner

    2004-01-01

    The purpose of this report is to evaluate and document the screening of the clad degradation features, events, and processes (FEPs) with respect to modeling used to support the Total System Performance Assessment-License Application (TSPA-LA). This report also addresses the effect of certain FEPs on both the cladding and the commercial spent nuclear fuel (CSNF), DOE-owned spent nuclear fuel (DSNF), and defense high-level waste (DHLW) waste forms, as appropriate to address the effects on multiple materials and both components (FEPs 2.1.09.09.0A, 2.1.09.11.0A, 2.1.11.05.0A, 2.1.12.02.0A, and 2.1.12.03.0A). These FEPs are expected to affect the repository performance during the postclosure regulatory period of 10,000 years after permanent closure. Table 1-1 provides the list of cladding FEPs, including their screening decisions (include or exclude). The primary purpose of this report is to identify and document the analysis, screening decision, and TSPA-LA disposition (for included FEPs) or screening argument (for excluded FEPs) for these FEPs related to clad degradation. In some cases, where a FEP covers multiple technical areas and is shared with other FEP reports, this report may provide only a partial technical basis for the screening of the FEP. The full technical basis for shared FEPs is addressed collectively by the sharing FEP reports. The screening decisions and associated TSPA-LA dispositions or screening arguments from all of the FEP reports are cataloged in a project-specific FEPs database

  9. Promoting breast screening in Glasgow.

    Science.gov (United States)

    Cohen, L; Dobson, H; McGuire, F

    2000-03-01

    To establish whether there is a role for advertising in the promotion of the Breast Screening Programme and what the role of advertising might be. Four hundred and sixty questionnaires were completed by women attending their breast screening appointment. Quantitative and qualitative data were collected from the static unit at Calder Street and the mobile unit in Govan. The advertising (budget 30,000 Pounds) campaign ran over an eight week period in the Govan, Paisley Road West and Cardonald areas of Glasgow. Media used included press advertising, The Glasgow Underground, adshells, bus advertising (interiors) and poster distribution via local outlets. Forty-two per cent of the sample were aware of the campaign. Ninety-seven per cent liked the campaign images. Eighty eight per cent felt that breast screening should be advertised more. Screening uptake increased in the areas covered by the advertising campaign. Govan -58%-71% and Ibrox (Paisley Road West and Cardonald) -59%-61%. Women were very supportive of the role of advertising for the Breast Screening Programme. In particular they found the campaign images and messages reassuring, supportive and credible. Their views suggest that the role of advertising should be: To raise awareness of the service To make women more conscious of the benefits of screening To change public perceptions of the screening process However, it is recognised that a fully integrated approach is required for the promotion of the service to account for the improvement in uptake, as advertising cannot be expected to work in isolation.

  10. The MORPHEUS II protein crystallization screen

    Energy Technology Data Exchange (ETDEWEB)

    Gorrec, Fabrice, E-mail: fgorrec@mrc-lmb.cam.ac.uk [MRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge Biomedical Campus, Cambridge CB2 0QH (United Kingdom)

    2015-06-27

    MORPHEUS II is a 96-condition initial crystallization screen formulated de novo. The screen incorporates reagents selected from the Protein Data Bank to yield crystals that are not observed in traditional conditions. In addition, the formulation facilitates the optimization and cryoprotection of crystals. High-quality macromolecular crystals are a prerequisite for the process of protein structure determination by X-ray diffraction. Unfortunately, the relative yield of diffraction-quality crystals from crystallization experiments is often very low. In this context, innovative crystallization screen formulations are continuously being developed. In the past, MORPHEUS, a screen in which each condition integrates a mix of additives selected from the Protein Data Bank, a cryoprotectant and a buffer system, was developed. Here, MORPHEUS II, a follow-up to the original 96-condition initial screen, is described. Reagents were selected to yield crystals when none might be observed in traditional initial screens. Besides, the screen includes heavy atoms for experimental phasing and small polyols to ensure the cryoprotection of crystals. The suitability of the resulting novel conditions is shown by the crystallization of a broad variety of protein samples and their efficiency is compared with commercially available conditions.

  11. The MORPHEUS II protein crystallization screen

    International Nuclear Information System (INIS)

    Gorrec, Fabrice

    2015-01-01

    MORPHEUS II is a 96-condition initial crystallization screen formulated de novo. The screen incorporates reagents selected from the Protein Data Bank to yield crystals that are not observed in traditional conditions. In addition, the formulation facilitates the optimization and cryoprotection of crystals. High-quality macromolecular crystals are a prerequisite for the process of protein structure determination by X-ray diffraction. Unfortunately, the relative yield of diffraction-quality crystals from crystallization experiments is often very low. In this context, innovative crystallization screen formulations are continuously being developed. In the past, MORPHEUS, a screen in which each condition integrates a mix of additives selected from the Protein Data Bank, a cryoprotectant and a buffer system, was developed. Here, MORPHEUS II, a follow-up to the original 96-condition initial screen, is described. Reagents were selected to yield crystals when none might be observed in traditional initial screens. Besides, the screen includes heavy atoms for experimental phasing and small polyols to ensure the cryoprotection of crystals. The suitability of the resulting novel conditions is shown by the crystallization of a broad variety of protein samples and their efficiency is compared with commercially available conditions

  12. Assessing the efficacy of cancer screening

    Directory of Open Access Journals (Sweden)

    Gemma Jacklyn

    2017-07-01

    Full Text Available Background: Population-based cancer screening has been established for several types of cancer in Australia and internationally. Screening may perform differently in practice from randomised controlled trials, which makes evaluating programs complex. Materials and methods: We discuss how to assess the evidence of benefits and harms of cancer screening, including the main biases that can mislead clinicians and policy makers (such as volunteer, lead-time, length-time and overdiagnosis bias. We also discuss ways in which communication of risks can inform or mislead the community. Results: The evaluation of cancer screening programs should involve balancing the benefits and harms. When considering the overall worth of an intervention and allocation of scarce health resources, decisions should focus on the net benefits and be informed by systematic reviews. Communication of screening outcomes can be misleading. Many messages highlight the benefits while downplaying the harms, and often use relative risks and 5-year survival to persuade people to screen rather than support informed choice. Lessons learned: An evidence based approach is essential when evaluating and communicating the benefits and harms of cancer screening, to minimise misleading biases and the reliance on intuition.

  13. The mammography screening employee inreach program.

    Science.gov (United States)

    Robinson, Joanne; Seltzer, Vicki; Lawrence, Loretta; Autz, George; Kostroff, Karen; Weiselberg, Lora; Colagiacomo, Maria

    2007-02-01

    To determine whether our health care employees were undergoing mammography screening according to American Cancer Society guidelines and to determine whether aggressive outreach, education and streamlining of mammography scheduling could improve compliance. All female employees at North Shore University Hospital (NSUH) and several other health system facilities (SF) were sent mailings to their homes that included breast health education and mammography screening guidelines, a questionnaire regarding their own mammography screening history and the opportunity to have their mammography screening scheduled by the Mammography Screening Employee Inreach Program (MSEIP) coordinator. Of the approximately 2,700 female employees aged 40 and over at NSUH and SF, 2,235 (82.7%) responded to the questionnaire, and 1,455 had a mammogram done via the MSEIP. Of the 1,455, 43% either were overdue for a mammogram or had never had one. During a second year of the MSEIP at NSUH and SF, an additional 1,706 mammograms were done. People employed in health care jobs do not necessarily avail themselves of appropriate health care screening. An aggressive program that utilized education, outreach and assistance with scheduling was effective in increasing compliance with mammography screening.

  14. Tuberculosis screening in patients with HIV

    DEFF Research Database (Denmark)

    Bjerrum, Stephanie Mia Katrine; Bonsu, Frank; Hanson-Nortey, Nii Nortey

    2016-01-01

    BACKGROUND: Tuberculosis screening of people living with HIV (PLHIV) can contribute to early tuberculosis diagnosis and improved patient outcomes. Evidence-based guidelines for tuberculosis screening are available, but literature assessing their implementation and the quality of clinical practice...... is scarce. OBJECTIVES: To assess tuberculosis screening practices and the effectiveness of audit and performance feedback to improve quality of tuberculosis screening at HIV care clinics in Ghana. DESIGN: Healthcare providers at 10 large HIV care clinics prospectively registered patient consultations during...

  15. Confinement control mechanism for two-electron Hulthen quantum dots in plasmas

    Science.gov (United States)

    Bahar, M. K.; Soylu, A.

    2018-05-01

    In this study, for the first time, the energies of two-electron Hulthen quantum dots (TEHQdots) embedded in Debye and quantum plasmas modeled by the more general exponential cosine screened Coulomb (MGECSC) potential under the combined influence of electric and magnetic fields are investigated by numerically solving the Schrödinger equation using the asymptotic iteration method. To do this, the four different forms of the MGECSC potential, which set through the different cases of the potential parameters, are taken into consideration. We propose that plasma environments form considerable quantum mechanical effects for quantum dots and other atomic systems and that plasmas are important experimental arguments. In this study, by considering the quantum dot parameters, the external field parameters, and the plasma screening parameters, a control mechanism of the confinement on energies of TEHQdots and the frequency of the radiation emitted by TEHQdots as a result of any excitation is discussed. In this mechanism, the behaviors, similarities, the functionalities of the control parameters, and the influences of plasmas on these quantities are explored.

  16. App Improves Colorectal Cancer Screening Rates

    Science.gov (United States)

    Colorectal cancer screening reduces deaths from the disease, yet about one-third of Americans aren’t up to date with screening. In this Cancer Currents blog post, learn what happened when people waiting for routine checkups could order their own screening test using a computer app.

  17. Design of low cost glaucoma screening

    NARCIS (Netherlands)

    Niessen, A. G.; Langerhorst, C. T.; Geijssen, H. C.; Greve, E. L.

    1997-01-01

    In 1991 the Netherlands Glaucoma Patient Association organized a glaucoma screening survey. This survey was designed to evaluate the effectiveness of a low cost screening setting. During a screening period of 8 days, 1259 subjects over the age of 49 years were examined by a team of

  18. Strategies in screening for colon carcinoma

    NARCIS (Netherlands)

    de Wijkerslooth, T. R.; Bossuyt, P. M.; Dekker, E.

    2011-01-01

    Colorectal cancer is the second most common cancer in Europe and meets the criteria for population screening. Population screening should lead to a reduction in CRC-related mortality and incidence. Several options are available for CRC screening, which can be itemised as stool-based tests and

  19. Gestational diabetes mellitus in Europe: prevalence, current screening practice and barriers to screening.

    LENUS (Irish Health Repository)

    Buckley, B S

    2011-12-12

    Background:  Gestational diabetes mellitus is a potentially serious condition that affects many pregnancies and its prevalence is increasing. Evidence suggests early detection and treatment improves outcomes, but this is hampered by continued disagreement and inconsistency regarding many aspects of its diagnosis. Methods:  The Vitamin D and Lifestyle Intervention for Gestational Diabetes Mellitus Prevention (DALI) research programme aims to promote pan-European standards in the detection and diagnosis of gestational diabetes and to develop effective preventive interventions. To provide an overview of the context within which the programme will be conducted and its findings interpreted, systematic searching and narrative synthesis have been used to identify and review the best available European evidence relating to the prevalence of gestational diabetes, current screening practices and barriers to screening. Results:  Prevalence is most often reported as 2-6% of pregnancies. Prevalence may be lower towards the Northern Atlantic seaboard of Europe and higher in the Southern Mediterranean seaboard. Screening practice and policy is inconsistent across Europe, hampered by lack of consensus on testing methods, diagnostic glycaemic thresholds and the value of routine screening. Poor clinician awareness of gestational diabetes, its diagnosis and local clinical guidelines further undermine detection of gestational diabetes. Conclusions:  Europe-wide agreement on screening approaches and diagnostic standards for gestational diabetes could lead to better detection and treatment, improved outcomes for women and children and a strengthened evidence base. There is an urgent need for well-designed research that can inform decisions on best practice in gestational diabetes mellitus screening and diagnosis. © 2011 The Authors. Diabetic Medicine© 2011 Diabetes UK.

  20. Primary care physicians' reported use of pre-screening discussions for prostate cancer screening: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    Cooper Crystale P

    2009-03-01

    Full Text Available Abstract Background Professional medical organizations recommend individualized patient decision making about prostate cancer screening. Little is known about primary care physicians' use of pre-screening discussions to promote informed decision making for prostate cancer screening. The aim of this study is to explore physicians' use of pre-screening discussions and reasons why physicians would or would not try to persuade patients to be screened if they initially refuse testing. Methods Primary care physicians completed a self-administered survey about prostate cancer screening practices for informed decision making. Results Sixty-six physicians (75.9% completed the survey, and 63 were used in the analysis. Thirteen physicians (20.6% reported not using prescreening discussions, 45 (71.4% reported the use of prescreening discussions, and 3 (4.8% reported neither ordering the PSA test nor discussing it with patients. Sixty-nine percent of physicians who reported not having discussions indicated they were more likely to screen African American patients for prostate cancer, compared to 50% of physicians who reported the use of discussions (Chi-square(1 = 1.62, p = .20. Similarly, 91% of physicians who reported not having discussions indicated they are more likely to screen patients with a family history of prostate cancer, compared to 46% of those who reported the use of discussion (Chi-square(1 = 13.27, p Conclusion Although guidelines recommend discussing the risks and benefits of prostate cancer screening, physicians report varying practice styles. Future research needs to consider the nature of discussions and the degree to which informed decision making is being achieved in clinical practice.

  1. Quantifying the Value of Markers in Screening Programmes

    DEFF Research Database (Denmark)

    Østergaard, Søren Dinesen; Dinesen, Peter Thisted; Foldager, Leslie

    2010-01-01

    Existing methods used to rank the value of individual screening markers in screening programmes are inadequate. We have developed a simple Screening Marker Index: (Screening Marker Index = Positive Predictive Value x Sensitivity). The Screening Marker Index proved to be superior to existing indices...

  2. [ASCUS in screening].

    Science.gov (United States)

    Caprara, L; Monari, F; De Bianchi, P S; Amadori, A; Bondi, A

    2001-12-01

    The significance and use of the cytological diagnosis "atypical squamous cells of undetermined significance" (ASCUS) remain a major problem in cervical cancer screening. The prevalence of ASCUS by patient age has seldom been investigated. The present paper reports the prevalence of ASCUS in a large series of screening Pap smears from the Italian region of Emilia-Romagna. The study was based on the data collected by the Department of Health of the Emilia-Romagna Region for the first 3-year round (1997-1999) of a population-based screening programme (target age, 25-64 years). The age-specific frequency of ASCUS has been calculated as a prevalence rate per 1000 screened patients. A total of 597,386 women participated in the programme. Women diagnosed with ASCUS (n = 8205 or 13.7 per 1000) accounted for 49% of the recalls for colposcopy (n = 16,871, or 28.2 per 1000). The prevalence of diagnoses of low-grade squamous intraepithelial lesions (LG-SIL) decreased progressively with age while that of high-grade SIL was slightly higher between 30 and 39 years. The prevalence of ASCUS peaked at age 45-49 years (17.3 per 1000 subjects). The observed peak reflects the prevalence of (1) cytological changes closely associated with perimenopausal age and at least compatible with the ASCUS diagnosis, and (2) cytological abnormalities induced by hormone replacement therapy.

  3. Relationship of "don't know" responses to cancer knowledge and belief questions with colorectal cancer screening behavior.

    Science.gov (United States)

    Ellis, Erin M; Ferrer, Rebecca A; Taber, Jennifer M; Klein, William M P

    2018-04-01

    Answering "I don't know" (DK) to survey questions that assess risk perceptions is common and occurs more often among disenfranchised groups. Because these groups also are at greater disease risk, statistically omitting or recoding DK responses may disproportionately exclude or misrepresent responses from marginalized groups and misinform intervention efforts. Because little is known about how the DK response is related to health behaviors, we examined whether the relation between DK response and colorectal cancer (CRC) screening behavior differed, depending on the construct queried (knowledge vs. beliefs). Data from the Awareness and Beliefs about Cancer survey of U.S. adults aged 50 years or older (N = 1406) were used. Cancer symptom knowledge, cancer beliefs, and CRC screening history were assessed. DK response options were not offered but were recorded if spontaneously provided. Logistic regression tested whether DK response on knowledge and belief scales were associated with CRC screening. Adjusting for demographic factors, responding DK on ≥1 belief item was associated with lower odds of having been screened for CRC in the last 5 years, p DK response on ≥1 knowledge item was unassociated with screening, p = .48. DK responders to belief items were even less likely to have been screened than participants with negative beliefs about cancer, p = .011. DK responses are differentially associated with CRC screening, depending on the construct queried, suggesting different mechanisms may underlie DK responding or its relationship with screening. Addressing construct-specific causes of DK response may improve survey research and the interventions based on them. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. Experience with breast cancer, pre-screening perceived susceptibility and the psychological impact of screening

    DEFF Research Database (Denmark)

    Absetz, Pilvikki; Aro, Arja R; Sutton, Stephen R

    2003-01-01

    responded to the follow-ups. Psychological impact was measured as anxiety (STAI-S), depression (BDI), health-related concerns (IAS), and breast cancer-specific beliefs and concerns. Data was analyzed with repeated measures analyses of variance, with estimates of effect size based on Eta-squared. Women......This prospective study examined whether the psychological impact of organized mammography screening is influenced by women's pre-existing experience with breast cancer and perceived susceptibility (PS) to the disease. From a target population of 16,886, a random sample of women with a normal...... with breast cancer experience had higher risk perception already before screening invitation; after screening they were also more distressed. Women with high PS were more distressed than women with low PS also at pre-invitation. The distress was not alleviated by screening, but instead remained even after...

  5. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    Science.gov (United States)

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  6. Detection beyond the Debye screening length in a high-frequency nanoelectronic biosensor.

    Science.gov (United States)

    Kulkarni, Girish S; Zhong, Zhaohui

    2012-02-08

    Nanosensors based on the unique electronic properties of nanotubes and nanowires offer high sensitivity and have the potential to revolutionize the field of Point-of-Care (POC) medical diagnosis. The direct current (dc) detection of a wide array of organic and inorganic molecules has been demonstrated on these devices. However, sensing mechanism based on measuring changes in dc conductance fails at high background salt concentrations, where the sensitivity of the devices suffers from the ionic screening due to mobile ions present in the solution. Here, we successfully demonstrate that the fundamental ionic screening effect can be mitigated by operating single-walled carbon nanotube field effect transistor as a high-frequency biosensor. The nonlinear mixing between the alternating current excitation field and the molecular dipole field can generate mixing current sensitive to the surface-bound biomolecules. Electrical detection of monolayer streptavidin binding to biotin in 100 mM buffer solution is achieved at a frequency beyond 1 MHz. Theoretical modeling confirms improved sensitivity at high frequency through mitigation of the ionic screening effect. The results should promise a new biosensing platform for POC detection, where biosensors functioning directly in physiologically relevant condition are desired. © 2012 American Chemical Society

  7. High Throughput Screen for Novel Antimicrobials using a Whole Animal Infection Model

    Science.gov (United States)

    Moy, Terence I.; Conery, Annie L.; Larkins-Ford, Jonah; Wu, Gang; Mazitschek, Ralph; Casadei, Gabriele; Lewis, Kim; Carpenter, Anne E.; Ausubel, Frederick M.

    2009-01-01

    The nematode Caenorhabditis elegans is a unique whole animal model system for identifying small molecules with in vivo anti-infective properties. C. elegans can be infected with a broad range of human pathogens, including Enterococcus faecalis, an important human nosocomial pathogen with a mortality rate of up to 37% that is increasingly acquiring resistance to antibiotics. Here, we describe an automated, high throughput screen of 37,200 compounds and natural product extracts for those that enhance survival of C. elegans infected with E. faecalis. The screen uses a robot to accurately dispense live, infected animals into 384-well plates, and automated microscopy and image analysis to generate quantitative, high content data. We identified 28 compounds and extracts that were not previously reported to have antimicrobial properties, including 6 structural classes that cure infected C. elegans animals but do not affect the growth of the pathogen in vitro, thus acting by a mechanism of action distinct from antibiotics currently in clinical use. Our versatile and robust screening system can be easily adapted for other whole animal assays to probe a broad range of biological processes. PMID:19572548

  8. Does screen size matter for smartphones? Utilitarian and hedonic effects of screen size on smartphone adoption.

    Science.gov (United States)

    Kim, Ki Joon; Sundar, S Shyam

    2014-07-01

    This study explores the psychological effects of screen size on smartphone adoption by proposing an extended Technology Acceptance Model (TAM) that integrates an empirical comparison between large and small screens with perceived control, affective quality, and the original TAM constructs. A structural equation modeling analysis was conducted on data collected from a between-subjects experiment (N=130) in which users performed a web-based task on a smartphone with either a large (5.3 inches) or a small (3.7 inches) screen. Results show that a large screen, compared to a small screen, is likely to lead to higher smartphone adoption by simultaneously promoting both the utilitarian and hedonic qualities of smartphones, which in turn positively influence perceived ease of use of-and attitude toward-the device respectively. Implications and directions for future research are discussed.

  9. Neuro-Simulation Tool for Enhanced Oil Recovery Screening and Reservoir Performance Prediction

    Directory of Open Access Journals (Sweden)

    Soheil Bahrekazemi

    2017-09-01

    Full Text Available Assessment of the suitable enhanced oil recovery method in an oilfield is one of the decisions which are made prior to the natural drive production mechanism. In some cases, having in-depth knowledge about reservoir’s rock, fluid properties, and equipment is needed as well as economic evaluation. Both putting such data into simulation and its related consequent processes are generally very time consuming and costly.  In order to reduce study cases, an appropriate tool is required for primary screening prior to any operations being performed, to which leads reduction of time in design of ether pilot section or production under field condition. In this research, two different and useful screening tools are presented through a graphical user interface. The output of just over 900 simulations and verified screening criteria tables were employed to design the mentioned tools. Moreover, by means of gathered data and development of artificial neural networks, two dissimilar screening tools for proper assessment of suitable enhanced oil recovery method were finally introduced. The first tool is about the screening of enhanced oil recovery process based on published tables/charts and the second one which is Neuro-Simulation tool, concerns economical evaluation of miscible and immiscible injection of carbon dioxide, nitrogen and natural gas into the reservoir. Both of designed tools are provided in the form of a graphical user interface by which the user, can perceive suitable method through plot of oil recovery graph during 20 years of production, costs of gas injection per produced barrel, cumulative oil production, and finally, design the most efficient scenario.

  10. Psychosocial consequences of skin cancer screening

    Directory of Open Access Journals (Sweden)

    Patricia Markham Risica

    2018-06-01

    Full Text Available Screening for melanoma may save lives, but may also cause patient distress. One key reason that preventative visual skin examinations for skin cancer are not currently recommended is the inadequate available evidence to assess potential harm to psychosocial wellbeing. We investigated potential psychological harms and benefits of skin examinations by conducting telephone surveys in 2015 of 187 screened participants; all were ≥35 years old. Participants had their skin examined by practitioners who had completed INFORMED, a validated web-based training for detection of skin cancers, particularly melanoma. Participants underwent the Spielberger State-Trait Anxiety Inventory (STAI, Psychological Consequences of Screening (PCQ, Hospital Anxiety and Depression (HAD scale, and the 12-Item Short Form Health Survey (SF-12. Analyses were conducted in 2017. Of the entire study sample, 40% were thoroughly screened as determined by patient-reported level of undress and skin areas examined. Participants who were thoroughly screened: did not differ on negative psychosocial measures; scored higher on measures of positive psychosocial wellbeing (PCQ; and were more motivated to conduct monthly self-examinations and seek annual clinician skin examinations, compared to other participants (p < 0.05. Importantly, thoroughly screened patients were more likely to report skin prevention practices (skin self-examinations to identify a concerning lesion, practitioner provided skin exam, recommend skin examinations to peers, and feel satisfied with their skin cancer education than less thoroughly screened individuals (p < 0.01. Our results suggest that visual screening for skin cancer does not worsen patient psychosocial wellbeing and may be associated with improved skin cancer-related practices and attitudes. Keywords: Cancer, Melanoma, Cancer prevention, Screening

  11. Vision Screening

    Science.gov (United States)

    1993-01-01

    The Visi Screen OSS-C, marketed by Vision Research Corporation, incorporates image processing technology originally developed by Marshall Space Flight Center. Its advantage in eye screening is speed. Because it requires no response from a subject, it can be used to detect eye problems in very young children. An electronic flash from a 35 millimeter camera sends light into a child's eyes, which is reflected back to the camera lens. The photorefractor then analyzes the retinal reflexes generated and produces an image of the child's eyes, which enables a trained observer to identify any defects. The device is used by pediatricians, day care centers and civic organizations that concentrate on children with special needs.

  12. Screening Risk Evaluation methodology

    International Nuclear Information System (INIS)

    Hopper, K.M.

    1994-01-01

    The Screening Risk Evaluation (SRE) Guidance document is a set of guidelines provided for the uniform implementation of SREs performed on D ampersand D facilities. These guidelines are designed specifically for the completion of the second (semi-quantitative screening) phase of the D ampersand D Risk-Based Process. The SRE Guidance produces screening risk scores reflecting levels of risk through the use of risk ranking indices. Five types of possible risk are calculated from the SRE: current releases, worker exposures, future releases, physical hazards, and criticality. The Current Release Index (CRI) calculates the risk to human health and the environment from ongoing or probable releases within a one year time period. The Worker Exposure Index (WEI) calculates the risk to workers, occupants, and visitors in D ampersand D facilities of contaminant exposure. The Future Release Index (FRI) calculates the risk of future releases of contaminants, after one year, to human health and the environment. The Physical Hazards Index (PHI) calculates the risk-to human health due to factors other than that of contaminants. The index of Criticality is approached as a modifying factor to the entire SRE, due to the fact that criticality issues are strictly regulated under DOE. Screening risk results will be tabulated in matrix form and Total Risk will be calculated (weighted equation) to produce a score on which to base early action recommendations. Other recommendations from the screening risk scores will be made based either on individual index scores or from reweighted Total Risk calculations. All recommendations based on the SRE will be made based on a combination of screening risk scores, decision drivers, and other considerations, determined on a project by project basis. The SRE is the first and most important step in the overall D ampersand D project level decision making process

  13. Improving rates of screening and prevention by leveraging existing information systems.

    Science.gov (United States)

    Neil, Nancy

    2003-11-01

    In 1997 Virginia Mason Health System (VMMC), a vertically integrated hospital and multispecialty group practice, had no process or system to deliver the right patient clinical data, in the right form, at the right place--when providers needed it for effective patient care. Without any new investment in technology, a work group of five individuals leveraged existing, primarily paper-based information systems to launch development and implementation of a provider prompting tool--a primary care and prevention (PCP) report--which prompted providers to complete screening, prevention, and disease management services at every patient appointment. The work group developed and pilot tested the report and created a mechanism by which the report could be delivered just in time before each patient's appointment. The report integrated information from independent appointment scheduling, laboratory results reporting, patient demographics, and billing data sources. MEASURING THE PCP REPORT'S IMPACT: The results of two separate analyses demonstrate improvement in rates of screening and prevention across VMMC soon after the PCP report became available. These results led senior leadership to make the PCP report's utilization a systemwide imperative. The PCP report is used by nearly all primary care providers as a prompt to complete screening, prevention, and disease management services at every patient appointment.

  14. Screening for Chronic Kidney Disease

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Chronic Kidney Disease The U.S. Preventive Services Task Force (Task Force) has issued a final recommendation on Screening for Chronic Kidney Disease (CKD) . This recommendation ...

  15. Glucose screening tests during pregnancy

    Science.gov (United States)

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... screening test between 24 and 28 weeks of pregnancy. The test may be done earlier if you ...

  16. Mammographic screening programmes in Europe

    DEFF Research Database (Denmark)

    Giordano, Livia; von Karsa, Lawrence; Tomatis, Mariano

    2012-01-01

    To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe.......To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe....

  17. Hazard screening application guide

    International Nuclear Information System (INIS)

    1992-06-01

    The basic purpose of hazard screening is to group precesses, facilities, and proposed modifications according to the magnitude of their hazards so as to determine the need for and extent of follow on safety analysis. A hazard is defined as a material, energy source, or operation that has the potential to cause injury or illness in human beings. The purpose of this document is to give guidance and provide standard methods for performing hazard screening. Hazard screening is applied to new and existing facilities and processes as well as to proposed modifications to existing facilities and processes. The hazard screening process evaluates an identified hazards in terms of the effects on people, both on-site and off-site. The process uses bounding analyses with no credit given for mitigation of an accident with the exception of certain containers meeting DOT specifications. The process is restricted to human safety issues only. Environmental effects are addressed by the environmental program. Interfaces with environmental organizations will be established in order to share information

  18. Effectiveness and costeffectiveness of screening immigrants ...

    African Journals Online (AJOL)

    Background: Immigrants to developed countries are a major source of TB. Therefore amongst strategies adopted for TB control in developed countries include; 1) Screening immigrants at ports of entry referred to as “Port of Arrival Screening” (PoA) and 2) Passive screening (PS) for TB which means screening immigrants ...

  19. Is the tide turning against breast screening?

    DEFF Research Database (Denmark)

    Jørgensen, Karsten Juhl

    2012-01-01

    ABSTRACT: Herein I argue that mammographic screening has not delivered on its fundamental premise: to reduce the incidence of advanced breast cancer. Indeed, achieving this goal is required if screening is to reduce breast cancer mortality or mastectomy use. Rather, screening has caused substantial...... increases in the incidence of in situ and early invasive cancers. Moreover, evidence indicates that these screen-detected cancers are unlikely to be cases that were 'caught early', but instead represent women who would not have been diagnosed in the absence of screening and who, as a result, have received...... harmful, unnecessary treatment. If true, these observations raise the specter that screening creates breast cancer patients and that this practice carries little or no benefit....

  20. The genetic origins of biosynthesis and light-responsive control of the chemical UV screen of land plants

    International Nuclear Information System (INIS)

    Jorgensen, R.

    1994-01-01

    Most land plants possess the capacity to protect themselves from UV light, and do so by producing pigments that absorb efficiently in the UV-A and UV-B regions of the spectrum while allowing transmission of nearly all photosynthetically useful wavelengths. These UV-absorbing pigments are mainly phenylpropanoids and flavonoids. This chapter summarizes current understanding of the mechanism of UV protection in higher land plants, evaluates the information available from lower land plants and their green-algal relatives, and then considers the possible evolutionary origins of this use of chemical filters for selectively screening UV light from solar radiation. It is proposed that photo control over the biosynthesis of UV-absorbing phenylpropanoids and flavonoids may have evolved in concert with the evolution of the high biosynthetic activity necessary for UV protection. The toxicity of phenylpropanoids and flavonoids has been postulated to have been a barrier to the evolution of an effective chemical UV screen, and that some means for sequestering these compounds and/or for controlling their synthesis probably evolved prior to, or in concert with, the evolution of high rates of biosynthesis. The original photoreceptor and signal transduction system is speculated to have been based on photo isomerization of a phenylpropanoid ester and a pre-existing product feedback mechanism for controlling phenylpropanoid biosynthesis. Understanding the original mechanism for photo control of the chemical UV screen of land plants could be valuable for understanding the adaptability of extant land plants to rising levels of solar UV-B radiation and may suggest genetic strategies for engineering improved UV tolerance in crop plants. (author)

  1. Analysis of sustainable pest control using a pesticide and a screened refuge.

    Science.gov (United States)

    Ringland, John; George, Prasanth

    2011-05-01

    We describe and analyze a 'screened refuge' technique for indefinitely sustaining control of insect pests using transgenic pesticidal crops or an applied pesticide, even when resistance is not recessive. The screen is a physical barrier that restricts pest movement. In a deterministic discrete-time model of the use of this technique, we obtain asymptotic analytical formulas for the two important equilibria of the system in terms of the refuge size and the pest fitnesses, mutation rates, and mobility out of and into the refuge. One of the equilibria is stable and is the point at which the pest population is controlled. The other is a saddle whose stable manifold bounds the basin of attraction of the former: its location provides a measure of the tolerance of the control mechanism to perturbations in the resistant allele density.

  2. Dynamics Analysis of Castor Hulling in the Process of Air-and-Screen Cleaning

    Directory of Open Access Journals (Sweden)

    Gao Ruitao

    2016-01-01

    Full Text Available The air-and-screen cleaning mechanism of castor hulling is analyzed in this paper. And the numeric expression equations of the castor dynamics analysis are established. The correlation of floating speeds vp, air speeds w, the direction angle of airflow velocity β, the direction angle of vibration δ, the friction angle ϕ, the slip coefficient, the fell coefficient and the jumping coefficient are analyzed.

  3. Dynamics Analysis of Castor Hulling in the Process of Air-and-Screen Cleaning

    OpenAIRE

    Gao Ruitao; Cao Yuhua; Yao Liangliang; Jin Hong

    2016-01-01

    The air-and-screen cleaning mechanism of castor hulling is analyzed in this paper. And the numeric expression equations of the castor dynamics analysis are established. The correlation of floating speeds vp, air speeds w, the direction angle of airflow velocity β, the direction angle of vibration δ, the friction angle ϕ, the slip coefficient, the fell coefficient and the jumping coefficient are analyzed.

  4. PET or PET-CT with cancer screening

    International Nuclear Information System (INIS)

    Wang Taisong; Zhao Jinhua; Song Jianhua

    2007-01-01

    At present, cancer screening remains a lot of debate in contemporary medical practice. Many constitutes have done a lot of experiments in cancer screening. The same version is that recommendations and decisions regarding cancer screening should be based on reliable data, not self- approbation. Now, some institutes advocate 18 F-FDG PET or 18 F-FDG PET-CT for cancer screening, here, discussed status quo, potential financial, radiation safety and statistical data in 18 F-FDG PET or 18 F-FDG PET- CT cancer screening. (authors)

  5. Review on Molecular Mechanisms of Antifouling Compounds: An Update since 2012.

    Science.gov (United States)

    Chen, Lianguo; Qian, Pei-Yuan

    2017-08-28

    Better understanding of the mechanisms of antifouling compounds is recognized to be of high value in establishing sensitive biomarkers, allowing the targeted optimization of antifouling compounds and guaranteeing environmental safety. Despite vigorous efforts to find new antifouling compounds, information about the mechanisms of antifouling is still scarce. This review summarizes the progress into understanding the molecular mechanisms underlying antifouling activity since 2012. Non-toxic mechanisms aimed at specific targets, including inhibitors of transmembrane transport, quorum sensing inhibitors, neurotransmission blockers, adhesive production/release inhibitors and enzyme/protein inhibitors, are put forward for natural antifouling products or shelf-stable chemicals. Several molecular targets show good potential for use as biomarkers in future mechanistic screening, such as acetylcholine esterase for neurotransmission, phenoloxidase/tyrosinase for the formation of adhesive plaques, N -acyl homoserine lactone for quorum sensing and intracellular Ca 2+ levels as second messenger. The studies on overall responses to challenges by antifoulants can be categorized as general targets, including protein expression/metabolic activity regulators, oxidative stress inducers, neurotransmission blockers, surface modifiers, biofilm inhibitors, adhesive production/release inhibitors and toxic killing. Given the current situation and the knowledge gaps regarding the development of alternative antifoulants, a basic workflow is proposed that covers the indispensable steps, including preliminary mechanism- or bioassay-guided screening, evaluation of environmental risks, field antifouling performance, clarification of antifouling mechanisms and the establishment of sensitive biomarkers, which are combined to construct a positive feedback loop.

  6. Cervical screening in HPV-vaccinated populations.

    Science.gov (United States)

    Canfell, K

    2018-06-01

    Cervical screening with cytology has been the basis for substantial reductions in cervical cancer incidence and mortality in most high-income countries over the last few decades. More recently, there have been two key, parallel developments which have prompted a major re-consideration of cervical screening. The first is the emergence of evidence on the improved sensitivity of human papillomavirus (HPV) DNA testing compared to cytology, and the second is the large-scale deployment of prophylactic vaccination against HPV. A key challenge to be overcome before HPV screening could be introduced into national cervical screening programs was the specificity of an infection, for detection of precancerous lesions. This has been done in three ways: (1) by considering the appropriate age for starting HPV screening (30 years in unvaccinated populations and 25 years in populations with mature vaccination programs and high vaccine uptake) and the appropriate screening interval; (2) via development of clinical HPV tests, which are (by design) not as sensitive to low viral loads; and (3) by introducing effective triaging for HPV-positive women, which further risk-stratifies women before referral for diagnostic evaluation. This review discusses these major developments and describes how the benefits of HPV screening are being optimized in both unvaccinated and vaccinated populations.

  7. Imaging characteristics of different mammographic screens.

    Science.gov (United States)

    Kuhn, H; Knüpfer, W

    1992-01-01

    A study of mammography systems with green-emitting screens was conducted to determine how the image quality parameters (apart from dose requirement), such as modulation transfer function (MTF) and Wiener spectrum (WS), depend on the dye content of the compound and coating weight of the screen. In addition, the contribution to total noise of the individual components, i.e., film, screen, and quantum noise, was studied. The quantities derived from MTF and WS, namely detective quantum efficiency (DQE) and noise equivalent quanta (NEQ), were also investigated in regard to their dose dependency. It can be demonstrated that the MTF of the screens becomes more favorable when the dye content is increased, while noise is not significantly affected. This suggests the use of a mammography screen capable of greater detail recognition, requiring at least double the dose of today's conventional systems with approximately 80 microGy system dose. On the other hand, the manufacture of a screen with about 60% of the dose of the conventional system is possible with very little loss in image quality. For the systems in common use today (80 microGy), quantum noise represents a considerable share of the total noise at low spatial frequencies, whereas in high spatial frequencies, the graininess of the film dominates quantum noise and screen structure.

  8. Effect of Fee on Cervical Cancer Screening Attendance--ScreenFee, a Swedish Population-Based Randomised Trial.

    Science.gov (United States)

    Alfonzo, Emilia; Andersson Ellström, Agneta; Nemes, Szilard; Strander, Björn

    2016-01-01

    Attendance in the cervical cancer screening programme is one of the most important factors to lower the risk of contracting the disease. Attendance rates are often low in areas with low socioeconomic status. Charging a fee for screening might possibly decrease attendance in this population. Screening programme coverage is low in low socio-economic status areas in Gothenburg, Sweden, but has increased slightly after multiple interventions in recent years. For many years, women in the region have paid a fee for screening. We studied the effect of abolishing this fee in a trial emanating from the regular cervical cancer screening programme. Individually randomised controlled trial. All 3 124 women in three low-resource areas in Gothenburg, due for screening during the study period, were randomised to receive an offer of a free test or the standard invitation stating the regular fee of 100 SEK (≈11 €). The study was conducted during the first six months of 2013. Attendance was defined as a registered Pap smear within 90 days from the date the invitation was sent out. Attendance did not differ significantly between women who were charged and those offered free screening (RR 0.93; CI 0.85-1.02). No differences were found within the districts or as an effect of age, attendance after the most recent previous invitation or previous experience of smear taking. Abolishment of a modest screening fee in socially disadvantaged urban districts with low coverage, after previous multiple systematic interventions, does not increase attendance in the short term. Other interventions might be more important for increasing attendance in low socio-economic status areas. ClinicalTrials.gov NCT02378324.

  9. Risks of Endometrial Cancer Screening

    Science.gov (United States)

    ... Health history and certain medicines can affect the risk of developing endometrial cancer. Anything that increases your ... have abnormal vaginal bleeding, check with your doctor. Risks of Endometrial Cancer Screening Key Points Screening tests ...

  10. Risks of Esophageal Cancer Screening

    Science.gov (United States)

    ... alcohol use, and Barrett esophagus can affect the risk of developing esophageal cancer. Anything that increases the ... tissue gives off less light than normal tissue. Risks of Esophageal Cancer Screening Key Points Screening tests ...

  11. Risks of Cervical Cancer Screening

    Science.gov (United States)

    ... women. Human papillomavirus (HPV) infection is the major risk factor for cervical cancer. Although most women with ... clinical trials is available from the NCI website . Risks of Cervical Cancer Screening Key Points Screening tests ...

  12. Detection of secondary binding sites in proteins using fragment screening.

    Science.gov (United States)

    Ludlow, R Frederick; Verdonk, Marcel L; Saini, Harpreet K; Tickle, Ian J; Jhoti, Harren

    2015-12-29

    Proteins need to be tightly regulated as they control biological processes in most normal cellular functions. The precise mechanisms of regulation are rarely completely understood but can involve binding of endogenous ligands and/or partner proteins at specific locations on a protein that can modulate function. Often, these additional secondary binding sites appear separate to the primary binding site, which, for example for an enzyme, may bind a substrate. In previous work, we have uncovered several examples in which secondary binding sites were discovered on proteins using fragment screening approaches. In each case, we were able to establish that the newly identified secondary binding site was biologically relevant as it was able to modulate function by the binding of a small molecule. In this study, we investigate how often secondary binding sites are located on proteins by analyzing 24 protein targets for which we have performed a fragment screen using X-ray crystallography. Our analysis shows that, surprisingly, the majority of proteins contain secondary binding sites based on their ability to bind fragments. Furthermore, sequence analysis of these previously unknown sites indicate high conservation, which suggests that they may have a biological function, perhaps via an allosteric mechanism. Comparing the physicochemical properties of the secondary sites with known primary ligand binding sites also shows broad similarities indicating that many of the secondary sites may be druggable in nature with small molecules that could provide new opportunities to modulate potential therapeutic targets.

  13. Cyanobacterial Xenobiotics as Evaluated by a Caenorhabditis elegans Neurotoxicity Screening Test

    Science.gov (United States)

    Ju, Jingjuan; Saul, Nadine; Kochan, Cindy; Putschew, Anke; Pu, Yuepu; Yin, Lihong; Steinberg, Christian E. W.

    2014-01-01

    In fresh waters cyanobacterial blooms can produce a variety of toxins, such as microcystin variants (MCs) and anatoxin-a (ANA). ANA is a well-known neurotoxin, whereas MCs are hepatotoxic and, to a lesser degree, also neurotoxic. Neurotoxicity applies especially to invertebrates lacking livers. Current standardized neurotoxicity screening methods use rats or mice. However, in order to minimize vertebrate animal experiments as well as experimental time and effort, many investigators have proposed the nematode Caenorhabditis elegans as an appropriate invertebrate model. Therefore, four known neurotoxic compounds (positive compounds: chlorpyrifos, abamectin, atropine, and acrylamide) were chosen to verify the expected impacts on autonomic (locomotion, feeding, defecation) and sensory (thermal, chemical, and mechanical sensory perception) functions in C. elegans. This study is another step towards successfully establishing C. elegans as an alternative neurotoxicity model. By using this protocol, anatoxin-a adversely affected locomotive behavior and pharyngeal pumping frequency and, most strongly, chemotactic and thermotactic behavior, whereas MC-LR impacted locomotion, pumping, and mechanical behavior, but not chemical sensory behavior. Environmental samples can also be screened in this simple and fast way for neurotoxic characteristics. The filtrate of a Microcystis aeruginosa culture, known for its hepatotoxicity, also displayed mild neurotoxicity (modulated short-term thermotaxis). These results show the suitability of this assay for environmental cyanotoxin-containing samples. PMID:24776722

  14. Genetic Screen Reveals the Role of Purine Metabolism in Staphylococcus aureus Persistence to Rifampicin

    Directory of Open Access Journals (Sweden)

    Rebecca Yee

    2015-12-01

    Full Text Available Chronic infections with Staphylococcus aureus such as septicemia, osteomyelitis, endocarditis, and biofilm infections are difficult to treat because of persisters. Despite many efforts in understanding bacterial persistence, the mechanisms of persister formation in S. aureus remain elusive. Here, we performed a genome-wide screen of a transposon mutant library to study the molecular mechanisms involved in persistence of community-acquired S. aureus. Screening of the library for mutants defective in persistence or tolerance to rifampicin revealed many genes involved in metabolic pathways that are important for antibiotic persistence. In particular, the identified mutants belonged to metabolic pathways involved in carbohydrate, amino acid, lipid, vitamin and purine biosynthesis. Five mutants played a role in purine biosynthesis and two mutants, purB, an adenylosuccinate lyase, and purM, a phosphoribosylaminoimidazole synthetase, were selected for further confirmation. Mutants purB and purM showed defective persistence compared to the parental strain USA300 in multiple stress conditions including various antibiotics, low pH, and heat stress. The defect in persistence was restored by complementation with the wildtype purB and purM gene in the respective mutants. These findings provide new insights into the mechanisms of persistence in S. aureus and provide novel therapeutic targets for developing more effective treatment for persistent infections due to S. aureus.

  15. Breast cancer screening with digital breast tomosynthesis.

    Science.gov (United States)

    Skaane, Per

    2017-01-01

    To give an overview of studies comparing full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in breast cancer screening. The implementation of tomosynthesis in breast imaging is rapidly increasing world-wide. Experimental clinical studies of relevance for DBT screening have shown that tomosynthesis might have a great potential in breast cancer screening, although most of these retrospective reading studies are based on small populations, so that final conclusions are difficult to draw from individual reports. Several retrospective studies and three prospective trials on tomosynthesis in breast cancer screening have been published so far, confirming the great potential of DBT in mammography screening. The main results of these screening studies are presented. The retrospective screening studies from USA have all shown a significant decrease in the recall rate using DBT as adjunct to mammography. Most of these studies have also shown an increase in the cancer detection rate, and the non-significant results in some studies might be explained by a lack of statistical power. All the three prospective European trials have shown a significant increase in the cancer detection rate. The retrospective and the prospective screening studies comparing FFDM and DBT have all demonstrated that tomosynthesis has a great potential for improving breast cancer screening. DBT should be regarded as a better mammogram that could improve or overcome limitations of the conventional mammography, and tomosynthesis might be considered as the new technique in the next future of breast cancer screening.

  16. Beliefs Underlying Messages of Anti-Cancer-Screening

    Science.gov (United States)

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro

    2018-02-26

    Background: Cancer screening rates are lower in Japan than in Western countries. Meanwhile, anti-cancer-screening activists take to the internet to spread their messages that cancer screening has little or no efficacy, poses substantial health risks such as side effects from radiation exposure, and that people should forgo cancer screening. We applied a qualitative approach to explore the beliefs underlying the messages of anti-cancer-screening websites, by focusing on perceived value the beliefs provided to those who held them. Methods: We conducted online searches using Google Japan and Yahoo! Japan, targeting websites we classified as “pro,” “anti,” or “neutral” depending on their claims. We applied a dual analytic approach- inductive thematic analysis and deductive interpretative analysis- to the textual data of the anti websites. Results: Of the 88 websites analyzed, five themes that correspond to beliefs were identified: destruction of common knowledge, denial of standard cancer control, education about right cancer control, education about hidden truths, and sense of superiority that only I know the truth. Authors of anti websites ascribed two values (“safety of people” and “self-esteem”) to their beliefs. Conclusion: The beliefs of authors of anti-cancer-screening websites were supposed to be strong. It would be better to target in cancer screening promotion not outright screening refusers but screening hesitant people who are more amenable to changing their attitudes toward screening. The possible means to persuade them were discussed. Creative Commons Attribution License

  17. Colorectal cancer screening

    OpenAIRE

    McLoughlin, Monica Ramona

    2008-01-01

    Colorectal cancer is a major public health burden and is the most common cause of mortality from cancer in Europe. Over the last two decades robust evidence from randomised clinical trials and case-control series have confirmed that the mortality from colorectal cancer can be reduced by screening. The challenge over the next decade is how to implement this in clinical practice. This is what we set out to answer with this thesis. Not all individuals are equal when it comes to screening and tho...

  18. Modified Debye screening potential in a magnetized quantum plasma

    International Nuclear Information System (INIS)

    Salimullah, M.; Hussain, A.; Sara, I.; Murtaza, G.; Shah, H.A.

    2009-01-01

    The effects of quantum mechanical influence and uniform static magnetic field on the Shukla-Nambu-Salimullah potential in an ultracold homogeneous electron-ion Fermi plasma have been examined in detail. It is noticed that the strong quantum effect arising through the Bohm potential and the ion polarization effect can give rise to a new oscillatory behavior of the screening potential beyond the shielding cloud which could explain a new type of possible robust ordered structure formation in the quantum magnetoplasma. However, the magnetic field enhances the Debye length perpendicular to the magnetic field in the weak quantum limit of the quantum plasma.

  19. Primary care physicians' reported use of pre-screening discussions for prostate cancer screening: a cross-sectional survey.

    Science.gov (United States)

    Linder, Suzanne K; Hawley, Sarah T; Cooper, Crystale P; Scholl, Lawrence E; Jibaja-Weiss, Maria; Volk, Robert J

    2009-03-18

    Professional medical organizations recommend individualized patient decision making about prostate cancer screening. Little is known about primary care physicians' use of pre-screening discussions to promote informed decision making for prostate cancer screening. The aim of this study is to explore physicians' use of pre-screening discussions and reasons why physicians would or would not try to persuade patients to be screened if they initially refuse testing. Primary care physicians completed a self-administered survey about prostate cancer screening practices for informed decision making. Sixty-six physicians (75.9%) completed the survey, and 63 were used in the analysis. Thirteen physicians (20.6%) reported not using prescreening discussions, 45 (71.4%) reported the use of prescreening discussions, and 3 (4.8%) reported neither ordering the PSA test nor discussing it with patients. Sixty-nine percent of physicians who reported not having discussions indicated they were more likely to screen African American patients for prostate cancer, compared to 50% of physicians who reported the use of discussions (Chi-square(1) = 1.62, p = .20). Similarly, 91% of physicians who reported not having discussions indicated they are more likely to screen patients with a family history of prostate cancer, compared to 46% of those who reported the use of discussion (Chi-square(1) = 13.27, p practice styles. Future research needs to consider the nature of discussions and the degree to which informed decision making is being achieved in clinical practice.

  20. Self-Screening for Malnutrition Risk in Outpatient Inflammatory Bowel Disease Patients Using the Malnutrition Universal Screening Tool (MUST).

    Science.gov (United States)

    Sandhu, Amindeep; Mosli, Mahmoud; Yan, Brian; Wu, Thomas; Gregor, Jamie; Chande, Nilesh; Ponich, Terry; Beaton, Melanie; Rahman, Adam

    2016-05-01

    Malnutrition is common in patients with inflammatory bowel disease (IBD) and is associated with poor outcomes. Our aim is to determine if patient self-administered malnutrition screening using the malnutrition universal screening tool (MUST) is reliable by comparing patient scores with those derived from the healthcare practitioner (HCP), the gold standard. We conducted a prospective validation study at a tertiary Canadian academic center that included 154 adult outpatients with IBD. All patients with IBD completed a self-administered nutrition screening assessment using the MUST score followed by an independent MUST assessment performed by HCPs. The main outcome measure was chance-corrected agreement (κ) of malnutrition risk categorization. For patient-administered MUST, the chance-corrected agreement κ (95% confidence interval [CI]) was 0.83 (0.74-0.92) when comparing low-risk and combined medium- and high-risk patients with HCP screening. Weighted κ analysis comparing all 3 risks groups yielded a κ (95% CI) of 0.85 (0.77-0.93) between patient and HCP screening. All patients were able to screen themselves. Overall, 96% of patients reported the MUST questionnaire as either very easy or easy to understand and to complete. Self-administered nutrition screening in outpatients with IBD is valid using the MUST screening tool and is easy to use. If adopted, this tool will increase utilization of malnutrition screening in hectic outpatient clinic settings and will help HCPs determine which patients require additional nutrition support. © 2015 American Society for Parenteral and Enteral Nutrition.

  1. CT screening for lung cancer. Update 2008

    International Nuclear Information System (INIS)

    Henschke, C.I.; Yip, R.; Yankelevitz, D.F.

    2009-01-01

    Screening for a cancer should be considered when the cancer is significant in terms of incidence and mortality, treatment of early stage disease is better than treatment of late stage disease, and there is a screening regimen that provides for earlier diagnosis rather than later, symptom-prompted diagnosis. Lung cancer qualifies as it kills more people than any other cancer worldwide. In the United States it kills more people than colon, breast, and prostate cancer combined and more women than breast cancer. The fundamental concepts of screening are presented. Screening for a cancer is a repetitive process, starting with the baseline round followed by repeat rounds of screening at set intervals. The regimen of screening defines the initial diagnostic test and the sequence of tests to be performed leading to a rule-in diagnosis of the cancer. The regimen should provide lead time of the diagnosis of the cancer. The regimen for the first, baseline round may be different from the regimen for the repeat rounds as the former is inherently different from the subsequent repeat rounds. Baseline screening identifies a greater proportion of cancers with a longer latent (asymptomatic) phase than repeat screening, called length bias. Length bias exists for any screening program, regardless of the design of the study or the cancer. Repeat rounds of screening identify the same proportion of cancer diagnoses found in absence of screening for people having the same risk of the cancer and these repeat rounds of screening can be pooled. It is also a consequence of length bias that cancers found in repeat rounds are earlier in their latent phase than those of the baseline round, a less frequently mentioned consequence. Overdiagnosis bias, another bias of screening, can occur in two ways: a cancer' detected by the screening, pathologically proven, that is not life-threatening even when not resected and a genuine life-threatening cancer that is diagnosed and treated but the person dies

  2. A chemical genetic screen for modulators of asymmetrical 2,2'-dimeric naphthoquinones cytotoxicity in yeast.

    Directory of Open Access Journals (Sweden)

    Ashkan Emadi

    Full Text Available BACKGROUND: Dimeric naphthoquinones (BiQ were originally synthesized as a new class of HIV integrase inhibitors but have shown integrase-independent cytotoxicity in acute lymphoblastic leukemia cell lines suggesting their use as potential anti-neoplastic agents. The mechanism of this cytotoxicity is unknown. In order to gain insight into the mode of action of binaphthoquinones we performed a systematic high-throughput screen in a yeast isogenic deletion mutant array for enhanced or suppressed growth in the presence of binaphthoquinones. METHODOLOGY/PRINCIPAL FINDINGS: Exposure of wild type yeast strains to various BiQs demonstrated inhibition of yeast growth with IC(50s in the microM range. Drug sensitivity and resistance screens were performed by exposing arrays of a haploid yeast deletion mutant library to BiQs at concentrations near their IC(50. Sensitivity screens identified yeast with deletions affecting mitochondrial function and cellular respiration as having increased sensitivity to BiQs. Corresponding to this, wild type yeast grown in the absence of a fermentable carbon source were particularly sensitive to BiQs, and treatment with BiQs was shown to disrupt the mitochondrial membrane potential and lead to the generation of reactive oxygen species (ROS. Furthermore, baseline ROS production in BiQ sensitive mutant strains was increased compared to wild type and could be further augmented by the presence of BiQ. Screens for resistance to BiQ action identified the mitochondrial external NAD(PH dehydrogenase, NDE1, as critical to BiQ toxicity and over-expression of this gene resulted in increased ROS production and increased sensitivity of wild type yeast to BiQ. CONCLUSIONS/SIGNIFICANCE: In yeast, binaphthoquinone cytotoxicity is likely mediated through NAD(PH:quonine oxidoreductases leading to ROS production and dysfunctional mitochondria. Further studies are required to validate this mechanism in mammalian cells.

  3. Quantum mechanical ab initio simulation of the electron screening effect in metal deuteride crystals

    Energy Technology Data Exchange (ETDEWEB)

    Huke, A.; Chun, S.M.; Biller, A.; Heide, P. [Technische Universitaet Berlin, Institut fuer Optik und Atomare Physik, Berlin (Germany); Czerski, K. [Technische Universitaet Berlin, Institut fuer Optik und Atomare Physik, Berlin (Germany); University of Szczecin, Institute of Physics, Szczecin (Poland)

    2008-02-15

    In antecedent experiments the electron screening energies of the d+d reactions in metallic environments have been determined to be enhanced by an order of magnitude in comparison to the case of gaseous deuterium targets. The analytical models describing averaged material properties have not been able to explain the experimental results so far. Therefore, a first effort has been undertaken to simulate the dynamics of reacting deuterons in a metallic lattice by means of an ab initio Hartree-Fock calculation of the total electrostatic force between the lattice and the successively approaching deuterons via path integration. The calculations have been performed for Li and Ta, clearly showing a migration of electrons from host metallic to the deuterium atoms. However, in order to avoid more of the necessary simplifications in the model the utilization of a massive parallel supercomputer would be required. (orig.) 3.

  4. Evaluation of a screening system for obesogenic compounds: screening of endocrine disrupting compounds and evaluation of the PPAR dependency of the effect.

    Directory of Open Access Journals (Sweden)

    Anna Pereira-Fernandes

    Full Text Available Recently the environmental obesogen hypothesis has been formulated, proposing a role for endocrine disrupting compounds (EDCs in the development of obesity. To evaluate this hypothesis, a screening system for obesogenic compounds is urgently needed. In this study, we suggest a standardised protocol for obesogen screening based on the 3T3-L1 cell line, a well-characterised adipogenesis model, and direct fluorescent measurement using Nile red lipid staining technique. In a first phase, we characterised the assay using the acknowledged obesogens rosiglitazone and tributyltin. Based on the obtained dose-response curves for these model compounds, a lipid accumulation threshold value was calculated to ensure the biological relevance and reliability of statistically significant effects. This threshold based method was combined with the well described strictly standardized mean difference (SSMD method for classification of non-, weak- or strong obesogenic compounds. In the next step, a range of EDCs, used in personal and household care products (parabens, musks, phthalates and alkylphenol compounds, were tested to further evaluate the obesogenicity screening assay for its discriminative power and sensitivity. Additionally, the peroxisome proliferator activated receptor γ (PPARγ dependency of the positive compounds was evaluated using PPARγ activation and antagonist experiments. Our results showed the adipogenic potential of all tested parabens, several musks and phthalate compounds and bisphenol A (BPA. PPARγ activation was associated with adipogenesis for parabens, phthalates and BPA, however not required for obesogenic effects induced by Tonalide, indicating the role of other obesogenic mechanisms for this compound.

  5. Prostate cancer screening: and yet it moves!

    Directory of Open Access Journals (Sweden)

    Maciej Kwiatkowski

    2015-06-01

    Full Text Available The debate of prostate cancer (PCa screening has been shaped over decades. There is a plethora of articles in the literature supporting as well as declining prostate-specific antigen (PSA screening. Does screening decrease PCa mortality? With the long-term results of the European Randomized Study of Screening for Prostate (ERSPC the answer is clearly YES. It moves! However, in medicine there are no benefits without any harm and thus, screening has to be performed in targeted and smart way-or in other words-in a risk-adapted fashion when compared with the way it was done in the past. Here, we discuss the main findings of the ERSPC trials and provide insights on how the future screening strategies should be implemented.

  6. Screening for thalassemia and other hemoglobinopathies in a tertiary care hospital of West Bengal: Implications for population screening

    OpenAIRE

    Bhawna Bhutoria Jain; Rabindra Nath Roy; Sulekha Ghosh; Tapan Ghosh; Uma Banerjee; Subodh Kumar Bhattacharya

    2012-01-01

    Hemoglobinopathies are common genetic disorders of hemoglobin, which can be prevented by population screening and offering genetic counseling. In absence of population-based screening for hemoglobinopathies, the hospital-based diagnosis register provide idea about the extent of problem in the community. The present study was undertaken to find out the burden of hemoglobinopathies and spectrum of this disorders among the population who were screened in the hospital-based screening program. A r...

  7. Italian Euromelanoma Day Screening Campaign (2005-2007) and the planning of melanoma screening strategies.

    Science.gov (United States)

    Seidenari, Stefania; Benati, Elisa; Ponti, Giovanni; Borsari, Stefania; Ferrari, Chiara; Albertini, Giuseppe; Altomare, Gianfranco; Arcangeli, Fabio; Aste, Nicola; Bernengo, Maria Grazia; Bongiorno, Maria Rita; Borroni, Giovanni; Calvieri, Stefano; Chimenti, Sergio; Cusano, Francesco; Fracchiolla, Claudio; Gaddoni, Giuseppe; Girolomoni, Giampiero; Guarneri, Biagio; Lanzoni, Anna; Lombardi, Mara; Lotti, Torello; Mariotti, Antonio; Marsili, Franco; Micali, Giuseppe; Parodi, Aurora; Peris, Ketty; Peserico, Andrea; Quaglino, Pietro; Santini, Marcello; Schiavon, Sergio; Tonino, Camillo; Trevisan, Giusto; Tribuzi, Paola; Valentini, Paolo; Vena, Gino A; Virgili, Annarosa

    2012-01-01

    Although no study has definitively shown that unfocused screening of skin cancer is effective, many campaigns have been organized with the aim of increasing awareness on melanoma risk factors. The objective of this study was to analyse the results of the Skin Cancer Screening Day in Italy during the period 2005-2007, to determine the priorities for melanoma control plans in a Mediterranean country. A total of 5002 patients were screened by dermatologists in 31 cities. Individuals who considered themselves to have many naevi and those with a family history of melanoma showed a higher number of common and atypical naevi. Ten melanomas, 20 basal cell carcinomas and two squamous cell carcinomas were histopathologically confirmed. Our observations provide the following suggestions for melanoma prevention strategies: (a) an unfocused campaign is suitable to inform the public about the importance of self-examination of the skin, but is not useful to identify a larger number of melanomas; and (b) melanoma screening campaigns should focus on a selected population, which meets rigorous risk criteria to maintain higher cost-effectiveness. The financial support to effective melanoma screening programmes could be increased, especially in southern populations where lower levels of self-surveillance and socioeconomic conditions represent risk factors for late identification of melanoma.

  8. Cross sectional associations of screen time and outdoor play with social skills in preschool children

    Science.gov (United States)

    Carson, Valerie

    2018-01-01

    Screen time and physical activity behaviours develop during the crucial early childhood period (0–5 years) and impact multiple health and developmental outcomes, including psychosocial wellbeing. Social skills, one component of psychosocial wellbeing, are vital for children’s school readiness and future mental health. This study investigates potential associations of screen time and outdoor play (as a proxy for physical activity) with social skills. Cross sectional data were available for 575 mothers with a child (54% boys) aged 2–5 years. Mothers reported their child’s screen time, outdoor play time and social skills (Adaptive Social Behavior Inventory; ASBI). Multiple linear regression analyses assessed associations of screen and outdoor play time (Model 1) and compliance with screen time and physical activity recommendations (Model 2) with three ASBI subscales. Boys and girls spent a mean of 2.0 and 2.2 hours per day in screen time, and 3.3 and 2.9 hours per day in outdoor play, respectively. Girls scores for express and comply skills were significantly higher than boys (poutdoor play time was positively associated with both expressive (B = 0.20 95% CI 0.07, 0.34; p = 0.004) and compliant (B = 0.22 95% CI 0.08, 0.36; p = 0.002) scores. Findings indicate that television/DVD/video viewing may be adversely, and outdoor play favourably, associated with preschool children’s social skills. Future research is required to identify the direction of causation and explore potential mechanisms of association. PMID:29617366

  9. Toward standardizing and reporting colorectal cancer screening indicators on an international level: The International Colorectal Cancer Screening Network

    NARCIS (Netherlands)

    Benson, Victoria S.; Atkin, Wendy S.; Green, Jane; Nadel, Marion R.; Patnick, Julietta; Smith, Robert A.; Villain, Patricia; Patnick, J.; Atkin, W. S.; Altenhofen, L.; Ancelle-Park, R.; Benson, V. S.; Green, J.; Levin, T. R.; Moss, S. M.; Nadel, M.; Ransohoff, D.; Segnan, N.; Smith, R. A.; Villain, P.; Weller, D.; Koukari, A.; Young, G.; López-Kostner, F.; Antoljak, N.; Suchánek, S.; Zavoral, M.; Holten, I.; Malila, N.; Salines, E.; Brenner, G.; Herszényi, L.; Tulassay, Z.; Rennert, G.; Senore, C.; Zappa, M.; Zorzi, M.; Saito, H.; Leja, M.; Dekker, E.; Jansen, J.; Hol, L.; Kuipers, E.; Kaminski, M. F.; Regula, J.; Sfarti, C.; Trifan, A.; Tang, C.-L.; Hrcka, R.; Binefa, G.; Espinàs, J. A.; Peris, M.; Chen, T. H.; Steele, R.; Pou, G.; Bisges, D.; Dwyer, D.; Groves, C.; Courteau, S.; Kramer, R.; Siegenthaler, K.; Lane, D.; Herrera, C.; Rogers, J.; Rojewski, M.; Wolf, Holly; Sung, J. J.; Ling, K.; Bryant, H.; Rabeneck, L.; Dale, J.; Sware, L.; Yang, H.; Viguier, J.; Von Karsa, L.; Kupcinskas, L.; Deutekom, M.; Törnberg, S.; Austoker, J.; Beral, V.; Monk, C.; Valori, R.; Watson, J.; Kobrin, S.; Pignone, M.; Taplin, S.

    2012-01-01

    The International Colorectal Cancer Screening Network was established in 2003 to promote best practice in the delivery of organized colorectal cancer screening programs. To facilitate evaluation of such programs, we defined a set of universally applicable colorectal cancer screening measures and

  10. Mathematical Models of the Sinusoidal Screen Family

    Directory of Open Access Journals (Sweden)

    Tajana Koren

    2011-06-01

    Full Text Available In this paper we will define a family of sinusoidal screening elements and explore the possibilities of their application in graphic arts, securities printing and design solutions in photography and typography editing. For this purpose mathematical expressions of sinusoidal families were converted into a Postscript language. The introduction of a random variable results in a countless number of various mutations which cannot be repeated without knowing the programming code itself. The use of the family of screens in protection of securities is thus of great importance. Other possible application of modulated sinusoidal screens is related to the large format color printing. This paper will test the application of sinusoidal screens in vector graphics, pixel graphics and typography. The development of parameters in the sinusoidal screen element algorithms gives new forms defined within screening cells with strict requirements of coverage implementation. Individual solutions include stochastic algorithms, as well as the autonomy of screening forms in regard to multicolor printing channels.

  11. A web-based platform for virtual screening.

    Science.gov (United States)

    Watson, Paul; Verdonk, Marcel; Hartshorn, Michael J

    2003-09-01

    A fully integrated, web-based, virtual screening platform has been developed to allow rapid virtual screening of large numbers of compounds. ORACLE is used to store information at all stages of the process. The system includes a large database of historical compounds from high throughput screenings (HTS) chemical suppliers, ATLAS, containing over 3.1 million unique compounds with their associated physiochemical properties (ClogP, MW, etc.). The database can be screened using a web-based interface to produce compound subsets for virtual screening or virtual library (VL) enumeration. In order to carry out the latter task within ORACLE a reaction data cartridge has been developed. Virtual libraries can be enumerated rapidly using the web-based interface to the cartridge. The compound subsets can be seamlessly submitted for virtual screening experiments, and the results can be viewed via another web-based interface allowing ad hoc querying of the virtual screening data stored in ORACLE.

  12. Diabetic retinopathy screening: global and local perspective.

    Science.gov (United States)

    Gangwani, R A; Lian, J X; McGhee, S M; Wong, D; Li, K Kw

    2016-10-01

    Diabetes mellitus has become a global epidemic. It causes significant macrovascular complications such as coronary artery disease, peripheral artery disease, and stroke; as well as microvascular complications such as retinopathy, nephropathy, and neuropathy. Diabetic retinopathy is known to be the leading cause of blindness in the working-age population and may be asymptomatic until vision loss occurs. Screening for diabetic retinopathy has been shown to reduce blindness by timely detection and effective laser treatment. Diabetic retinopathy screening is being done worldwide either as a national screening programme or hospital-based project or as a community-based screening programme. In this article, we review different methods of screening including grading used to detect the severity of sight-threatening retinopathy and the newer screening methods. This review also includes the method of systematic screening being carried out in Hong Kong, a system that has helped to identify diabetic retinopathy among all attendees in public primary care clinics using a Hong Kong-wide public patients' database.

  13. Outcome of breast cancer screening in Denmark

    DEFF Research Database (Denmark)

    Lynge, Elsebeth; Bak, Martin; von Euler-Chelpin, My

    2017-01-01

    were node negative and 40% ≤10 mm. False-positive rate was around 2%; higher for North Denmark Region than for the rest of Denmark. Three out of 10 breast cancers in screened women were diagnosed as interval cancers. Conclusions: High coverage by examination and low interval cancer rate are required...... for screening to decrease breast cancer mortality. Two pioneer local screening programs starting in the 1990s were followed by a decrease in breast cancer mortality of 22-25%. Coverage by examination and interval cancer rate of the national program were on the favorable side of values from the pioneer programs...... Region than in the rest of Denmrk. Detection rate was slightly below 1% at first screen, 0.6% at subsequent screens, and one region had some fluctuation over time. Ductal carcinoma in situ (DCIS) constituted 13-14% of screen-detected cancers. In subsequent rounds, 80% of screen-detected invasive cancers...

  14. The Potential Cost-Effectiveness of Amblyopia Screening Programs

    Science.gov (United States)

    Rein, David B.; Wittenborn, John S.; Zhang, Xinzhi; Song, Michael; Saaddine, Jinan B.

    2013-01-01

    Background To estimate the incremental cost-effectiveness of amblyopia screening at preschool and kindergarten, we compared the costs and benefits of 3 amblyopia screening scenarios to no screening and to each other: (1) acuity/stereopsis (A/S) screening at kindergarten, (2) A/S screening at preschool and kindergarten, and (3) photoscreening at preschool and A/S screening at kindergarten. Methods We programmed a probabilistic microsimulation model of amblyopia natural history and response to treatment with screening costs and outcomes estimated from 2 state programs. We calculated the probability that no screening and each of the 3 interventions were most cost-effective per incremental quality-adjusted life year (QALY) gained and case avoided. Results Assuming a minimal 0.01 utility loss from monocular vision loss, no screening was most cost-effective with a willingness to pay (WTP) of less than $16,000 per QALY gained. A/S screening at kindergarten alone was most cost-effective between a WTP of $17,000 and $21,000. A/S screening at preschool and kindergarten was most cost-effective between a WTP of $22,000 and $75,000, and photoscreening at preschool and A/S screening at kindergarten was most cost-effective at a WTP greater than $75,000. Cost-effectiveness substantially improved when assuming a greater utility loss. All scenarios were cost-effective when assuming a WTP of $10,500 per case of amblyopia cured. Conclusions All 3 screening interventions evaluated are likely to be considered cost-effective relative to many other potential public health programs. The choice of screening option depends on budgetary resources and the value placed on monocular vision loss prevention by funding agencies. PMID:21877675

  15. Evaluation of a workplace hemochromatosis screening program.

    Science.gov (United States)

    Stave, G M; Mignogna, J J; Powell, G S; Hunt, C M

    1999-05-01

    Hemochromatosis is a common inherited disorder of iron metabolism with significant health consequences for the employed population. Although screening for hemochromatosis has been recommended, workplace screening programs remain uncommon. In the first year of a newly initiated corporate screening program, 1968 employees were tested. The screening algorithm included measurement of serum iron and transferrin and subsequent ferritin levels in those employees with elevated iron/transferrin ratios. Thirteen percent of men and 21% of women had elevated iron/transferrin ratios. Of these, 14 men and 2 women had elevated ferritin levels. Of these 16, three had liver biopsies and all three have hemochromatosis. The cost of the screening program was $27,850. The cost per diagnosis was $9283 and the cost per year of life saved was $928. These costs compare very favorably with other common workplace screening programs. Several barriers to obtaining definitive diagnoses on all patients with a positive screening result were identified; strategies to overcome these barriers would further enhance the cost effectiveness of the program. We conclude that workplace hemochromatosis screening is highly cost effective and should be incorporated into health promotion/disease prevention programs.

  16. Micro-motor with screen-printed rotor magnets

    International Nuclear Information System (INIS)

    Speliotis, Thanassis; Niarchos, Dimitris; Meneroud, Patrick; Magnac, G.; Claeyssen, Franck; Pepin, John; Fermon, Claude; Pannetier, M.; Biziere, N.

    2007-01-01

    The feasibility to develop mini- and micro-magnetic electro-mechanical systems (MEMS) has been evaluated by prototyping of a single-phase stepper motor. The main targeted application of such device is the watch industry needing micro-motors in huge quantities at low cost. The motor part that required the greatest efforts has been the magnet, which cannot yet be found in film layer. The screen-printing technology has been used for the production of NdFeB-based magnets whose properties have been characterised. The thick film magnets have been integrated in the stepper motor specially designed for this purpose. The whole motor has been characterised and conclusions are drawn on the possibility of producing thick film magnets for magnetic MEMS

  17. Search for Screened Interactions Associated with Dark Energy below the 100 μm Length Scale.

    Science.gov (United States)

    Rider, Alexander D; Moore, David C; Blakemore, Charles P; Louis, Maxime; Lu, Marie; Gratta, Giorgio

    2016-09-02

    We present the results of a search for unknown interactions that couple to mass between an optically levitated microsphere and a gold-coated silicon cantilever. The scale and geometry of the apparatus enable a search for new forces that appear at distances below 100  μm and which would have evaded previous searches due to screening mechanisms. The data are consistent with electrostatic backgrounds and place upper limits on the strength of new interactions at 5.6×10^{4} in the region of parameter space where the self-coupling Λ≳5  meV and the microspheres are not fully screened.

  18. Market screening of natural gas reformers

    International Nuclear Information System (INIS)

    Themsen, J.; Pagh Nielsen, M.; Knudsen Kaer, S.

    2005-01-01

    This report presents results from the project: Market screening of natural gas reformers. The project objective was to screen the natural gas reformers available on the international market. The technology is developing rapidly, and the results from this project will assist in determining the focus for the future Danish activities and in setting up ambitious and realistic targets. The reformer screening is partly based on AAU and Dantherm's experiences from previous studies, and the screening has been further extended with a number of activities, including seminars and contact with some of the most interesting suppliers. (BA)

  19. VecScreen_plus_taxonomy: imposing a tax(onomy) increase on vector contamination screening.

    Science.gov (United States)

    Schäffer, Alejandro A; Nawrocki, Eric P; Choi, Yoon; Kitts, Paul A; Karsch-Mizrachi, Ilene; McVeigh, Richard

    2018-03-01

    Nucleic acid sequences in public databases should not contain vector contamination, but many sequences in GenBank do (or did) contain vectors. The National Center for Biotechnology Information uses the program VecScreen to screen submitted sequences for contamination. Additional tools are needed to distinguish true-positive (contamination) from false-positive (not contamination) VecScreen matches. A principal reason for false-positive VecScreen matches is that the sequence and the matching vector subsequence originate from closely related or identical organisms (for example, both originate in Escherichia coli). We collected information on the taxonomy of sources of vector segments in the UniVec database used by VecScreen. We used that information in two overlapping software pipelines for retrospective analysis of contamination in GenBank and for prospective analysis of contamination in new sequence submissions. Using the retrospective pipeline, we identified and corrected over 8000 contaminated sequences in the nonredundant nucleotide database. The prospective analysis pipeline has been in production use since April 2017 to evaluate some new GenBank submissions. Data on the sources of UniVec entries were included in release 10.0 (ftp://ftp.ncbi.nih.gov/pub/UniVec/). The main software is freely available at https://github.com/aaschaffer/vecscreen_plus_taxonomy. aschaffe@helix.nih.gov. Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2017. This work is written by US Government employees and are in the public domain in the US.

  20. Developing the Biomolecular Screening Facility at the EPFL into the Chemical Biology Screening Platform for Switzerland.

    Science.gov (United States)

    Turcatti, Gerardo

    2014-05-01

    The Biomolecular Screening Facility (BSF) is a multidisciplinary laboratory created in 2006 at the Ecole Polytechnique Federale de Lausanne (EPFL) to perform medium and high throughput screening in life sciences-related projects. The BSF was conceived and developed to meet the needs of a wide range of researchers, without privileging a particular biological discipline or therapeutic area. The facility has the necessary infrastructure, multidisciplinary expertise and flexibility to perform large screening programs using small interfering RNAs (siRNAs) and chemical collections in the areas of chemical biology, systems biology and drug discovery. In the framework of the National Centres of Competence in Research (NCCR) Chemical Biology, the BSF is hosting 'ACCESS', the Academic Chemical Screening Platform of Switzerland that provides the scientific community with chemical diversity, screening facilities and know-how in chemical genetics. In addition, the BSF started its own applied research axes that are driven by innovation in thematic areas related to preclinical drug discovery and discovery of bioactive probes.

  1. Single-item screening for agoraphobic symptoms : validation of a web-based audiovisual screening instrument

    NARCIS (Netherlands)

    van Ballegooijen, Wouter; Riper, Heleen; Donker, Tara; Martin Abello, Katherina; Marks, Isaac; Cuijpers, Pim

    2012-01-01

    The advent of web-based treatments for anxiety disorders creates a need for quick and valid online screening instruments, suitable for a range of social groups. This study validates a single-item multimedia screening instrument for agoraphobia, part of the Visual Screener for Common Mental Disorders

  2. Prostate cancer mortality in screen and clinically detected prostate cancer : Estimating the screening benefit

    NARCIS (Netherlands)

    van Leeuwen, Pim J.; Connolly, David; Gavin, Anna; Roobol, Monique J.; Black, Amanda; Bangma, Chris H.; Schroder, Fritz H.

    Background: To estimate the benefits of prostate-specific antigen (PSA) screening on prostate cancer (Pca) metastasis and Pca-specific mortality, we compared two populations with a well-defined difference in intensity of screening. Methods: Between 1997 and 1999, a total of 11,970 men, aged 55-74

  3. Effect of Fee on Cervical Cancer Screening Attendance—ScreenFee, a Swedish Population-Based Randomised Trial

    Science.gov (United States)

    Alfonzo, Emilia; Andersson Ellström, Agneta; Nemes, Szilard; Strander, Björn

    2016-01-01

    Background Attendance in the cervical cancer screening programme is one of the most important factors to lower the risk of contracting the disease. Attendance rates are often low in areas with low socioeconomic status. Charging a fee for screening might possibly decrease attendance in this population. Screening programme coverage is low in low socio-economic status areas in Gothenburg, Sweden, but has increased slightly after multiple interventions in recent years. For many years, women in the region have paid a fee for screening. We studied the effect of abolishing this fee in a trial emanating from the regular cervical cancer screening programme. Method Individually randomised controlled trial. All 3 124 women in three low-resource areas in Gothenburg, due for screening during the study period, were randomised to receive an offer of a free test or the standard invitation stating the regular fee of 100 SEK (≈11 €). The study was conducted during the first six months of 2013. Attendance was defined as a registered Pap smear within 90 days from the date the invitation was sent out. Results Attendance did not differ significantly between women who were charged and those offered free screening (RR 0.93; CI 0.85–1.02). No differences were found within the districts or as an effect of age, attendance after the most recent previous invitation or previous experience of smear taking. Conclusion Abolishment of a modest screening fee in socially disadvantaged urban districts with low coverage, after previous multiple systematic interventions, does not increase attendance in the short term. Other interventions might be more important for increasing attendance in low socio-economic status areas. Trial Registration ClinicalTrials.gov NCT02378324 PMID:26986848

  4. Increased breast cancer screening and downstaging in Colombian women: A randomized trial of opportunistic breast-screening.

    Science.gov (United States)

    Murillo, Raúl; Díaz, Sandra; Perry, Fernando; Poveda, César; Piñeros, Marion; Sánchez, Oswaldo; Buitrago, Lina; Gamboa, Oscar; Lozano, Teófilo; Yu, Hsiang; Wang, Ching-Yun; Duggan, Catherine; Thomas, David B; Anderson, Benjamin O

    2016-02-01

    The lack of breast cancer screening in low and middle-income countries results in later stage diagnosis and worsened outcomes for women. A cluster randomized trial was performed in Bogotá, Colombia between 2008 and 2012 to evaluate effects of opportunistic breast cancer screening. Thirteen clinics were randomized to an intervention arm and 13 to a control arm. Physicians in intervention clinics were instructed to perform clinical breast examination on all women aged 50-69 years attending clinics for non-breast health issues, and then refer them for mammographic screening. Physicians in control clinics were not explicitly instructed to perform breast screening or mammography referrals, but could do so if they thought it indicated ("usual care"). Women were followed for 2-years postrandomization. 7,436 women were enrolled and 7,419 (99.8%) screened in intervention clinics, versus 8,419 enrolled and 1,108 (13.1%) screened in control clinics. Incidence ratios (IR) of early, advanced and all breast cancers were 2.9 (95% CI 1.1-9.2), 1.0 (0.3-3.5) and 1.9 (0.9-4.1) in the first (screening) year of the trial, and the cumulative IR for all breast cancers converged to 1.4 (0.7-2.8) by the end of follow-up (Year 2). Eighteen (69.2%) of 26 women with early stage disease had breast conservation surgery (BCS) versus 6 (42.5%) of 14 women with late-stage disease (p = 0.02). Fifteen (68.2%) of 22 women with breast cancer in the intervention group had BCS versus nine (50.0%) of 18 women in the control group (p = 0.34). Well-designed opportunistic clinic-based breast cancer screening programs may be useful for early breast cancer detection in LMICs. © 2015 The Authors. Published by Wiley Periodicals, Inc. on behalf of UICC.

  5. Screening for breast cancer post reduction mammoplasty

    International Nuclear Information System (INIS)

    Muir, T.M.; Tresham, J.; Fritschi, L.; Wylie, E.

    2010-01-01

    Aim: To investigate whether remodelling of the breast after breast reduction surgery has an effect on mammographic cancer detection. Methods and materials: For women who attended population-based screening between January 1998 to December 2007, data were extracted on their age, history of previous breast reduction, and the result of screening (recall for further assessment, cancer, or no cancer). The number of cancers detected, recalls per 1000 screens and the characteristics of the cancers detected in the two groups was compared. Results: In total 244,147 women with 736,219 screening episodes were reviewed. In the 4743 women who had a breast reduction, 51 breast cancers were detected [age standardized rate (ASR) of 4.28 per 1000 screening episodes; 95% CI 3.11-5.46], compared with 4342 breast cancers in 239 404 women screened in the non-reduction group (ASR of 5.99 per 1000 screening episodes; 95% CI 5.81-6.16). There were fewer cancers in the breast reduction group with a relative risk of 0.71. There was no significant difference in the rate of recall between the two groups, with a crude recall rate of 46.1 per 1000 screening episodes post-breast reduction compared with 50.7 per 1000 screening episodes for women without breast reduction. There was no significant difference in the pathological type or location of the cancer between the two groups of women. Conclusion: Postoperative breast changes following reduction mammoplasty do not significantly hinder analysis of the screening mammogram.

  6. Impact of a public cholesterol screening program.

    Science.gov (United States)

    Fischer, P M; Guinan, K H; Burke, J J; Karp, W B; Richards, J W

    1990-12-01

    The National Cholesterol Education Program (NCEP) has endorsed physician case finding as the primary method to detect individuals with elevated cholesterol levels. Despite this recommendation, promotional and for-profit public screening programs have flourished. We surveyed participants of a mall-based cholesterol screening program 1 year after their screening. Sixty-four percent of those screened had not previously known their cholesterol levels. Those who were newly screened were less likely to benefit from this testing than the general public, since they were older (mean age, 55.3 years), more likely to be female (67.4%), and nonsmokers (88%). Screenees had excellent recall of their cholesterol level (mean absolute reporting error, 0.24 mmol/L [9 mg/dL]) and a good understanding of cholesterol as a coronary heart disease risk. Those with elevated cholesterol levels reported high distress from screening but no reduction in overall psychosocial well-being and an actual decrease in absenteeism. Only 53.7% of all who were advised to seek follow-up because of an elevated screening value had done so within the year following the screening program. However, of those with values greater than 6.2 mmol/L (240 mg/dL), 68% had sought follow-up. Many of those who participate in public screening programs have been previously tested, fall into low-benefit groups, or fail to comply with recommended follow-up. We therefore conclude that cholesterol screening programs of the type now commonly offered are unlikely to contribute greatly to the national efforts to further reduce coronary heart disease.

  7. Screening for colorectal cancer in Italy: 2011-2012 survey.

    Science.gov (United States)

    Zorzi, Manuel; Mangone, Lucia; Anghinoni, Emanuela; Baracco, Susanna; Borciani, Elisabetta; Caldarella, Adele; Falcini, Fabio; Fanetti, Anna Clara; Ferretti, Stefano; Giorgi Rossi, Paolo; Michiara, Maria; Randi, Giorgia; Stracci, Fabrizio; Vicentini, Massimo; Zucchetto, Antonella; Zappa, Marco

    2015-01-01

    The impact of organized screening programmes on colorectal cancer (CRC) can be observed at a population level only several years after the implementation of screening. We compared CRC characteristics by diagnostic modality (screen-detected, non-screen-detected) as an early outcome to monitor screening programme effectiveness. Data on CRCs diagnosed in Italy from 2000 to 2008 were collected by several cancer registries. Linkage with screening datasets made it possible to divide the cases by geographic area, implementation of screening, and modality of diagnosis (screen-detected, non-screen-detected).We compared the main characteristics of the different subgroups of CRCs through multivariate logistic regression models. The study included 23,668 CRCs diagnosed in subjects aged 50-69 years, of which 11.9% were screen-detected (N=2,806), all from the North-Centre of Italy. Among screen-detected CRCs, we observed a higher proportion of males, of cases in the distal colon, and a higher mean age of the patients. Compared with pre-screening cases, screen-detected CRCs showed a better distribution by stage at diagnosis (OR for stage III or IV: 0.40, 95%CI: 0.36-0.44) and grading (OR for poorly differentiated CRCs was 0.86, 95%CI: 0.75-1.00). Screen-detected CRCs have more favourable prognostic characteristics than non-screen-detected cases. A renewed effort to implement screening programmes throughout the entire country is recommended.

  8. Breast Cancer Screening in Denmark

    DEFF Research Database (Denmark)

    Jørgensen, Karsten Juhl; Gøtzsche, Peter C; Kalager, Mette

    2017-01-01

    Background: Effective breast cancer screening should detect early-stage cancer and prevent advanced disease. Objective: To assess the association between screening and the size of detected tumors and to estimate overdiagnosis (detection of tumors that would not become clinically relevant). Design......) and nonadvanced (≤20 mm) breast cancer tumors in screened and nonscreened women were measured. Two approaches were used to estimate the amount of overdiagnosis: comparing the incidence of advanced and nonadvanced tumors among women aged 50 to 84 years in screening and nonscreening areas; and comparing...... rate ratio, 1.49 [95% CI, 1.43 to 1.54]). The first estimation approach found that 271 invasive breast cancer tumors and 179 ductal carcinoma in situ (DCIS) lesions were overdiagnosed in 2010 (overdiagnosis rate of 24.4% [including DCIS] and 14.7% [excluding DCIS]). The second approach, which accounted...

  9. Pennsylvania's experience in mass screening

    International Nuclear Information System (INIS)

    Gerusky, T.M.

    1975-01-01

    A policy statement issued in 1972 by the Assistant Secretary for Health and Scientific Affairs of the Department of Health, Education, and Welfare recommended that community chest x-ray surveys should not be used as a screening procedure for the detection of cardiopulmonary disorders and that when chest x-ray screening programs are justified for selected population groups, the full size photograph, rather than the miniature film, is preferred. A survey conducted in 1974--75 revealed that chest x rays were required for prisoners, prison employees, school employees, food handlers, and students who wished to participate in sports. Meetings were held with medical associations in the hope of stopping the local mass-screening operations. Of 27 groups in Pennsylvania involved in tuberculosis screening, 12 groups refused or were unwilling to phase out their photofluorographic procedures. The problem will be resolved by regulation

  10. Radioactive PTT as part of screening protocol for prospecting radiation workers

    International Nuclear Information System (INIS)

    Nato, Alejandro Q. Jr.; Deocaris, Custer; Sajise, Sheila C.

    2002-04-01

    Heterozygous mutations in BRCA1 or BRCA2 (breast cancer)have been found to be associated with enhanced cellular radiosensitivity with impaired proliferative capacity after irradiation and could predispose increased risk of radiation-induced mutagenesis and carcinogenesis (1,2). Deficient repair mechanism exhibited by lymphocytes from breast cancer patients provides associated vulnerability to genotoxicity of ionizing radiation. Other genes ay also play a role in terms o clinical radiation hypersensitivity needed in predicting response to radiotherapy. However, relaxation of cell cycle checkpoints, production of micronuclei, and loss of proliferative capacity which have been exhibited by impairment of irradiated cells lacking functional BRCA1 and BRCA2, accentuate the notion that heterozygous women may respond differently to radiation. The radioactive protein truncation test (PTT), utilized as screening procedures to detect frameshift mutations, can be employed to clarify radiosensitivity of individuals carrying a mutated BRCA1 gene. It can therefore, be incorporated in the series of clinical assays used in standard screening protocols for prospective nuclear facility workers. (author)

  11. About the role of 2D screening in high temperature superconductivity

    International Nuclear Information System (INIS)

    Vazquez-Ponce, Y.; Oliva Aguero, D.; Cabo Montes de Oca, D.

    2005-09-01

    The 2D screening is investigated in a simple single band square tight-binding model which qualitatively resembles the known electronic structure in high temperature superconductors. The Coulomb kernel for the two particle Bethe-Salpeter equation in the single loop (RPA) approximation for the polarization can be evaluated in a strong tight binding limit. The results indicate an intense screening of the Coulomb repulsion between the particles, which becomes stronger and anisotropic when the Fermi level approaches half filling (or equivalently, when the Fermi surface turns to be near the Van Hove singularities) and rapidly decreases away from it. The effect is also more pronounced for quasi-momenta regions near the corners of the Brillouin cell, which corresponds to dual spatial distances of the order of a few unit cells. Therefore, a possible mechanism is identified which could explain the existence of extremely small Cooper pairs in these materials, as bounded anisotropic composite particles joined by residual superexchange or phonon interactions. (author)

  12. Screening for thalassemia and other hemoglobinopathies in a tertiary care hospital of West Bengal: implications for population screening.

    Science.gov (United States)

    Jain, Bhawna Bhutoria; Roy, Rabindra Nath; Ghosh, Sulekha; Ghosh, Tapan; Banerjee, Uma; Bhattacharya, Subodh Kumar

    2012-01-01

    Hemoglobinopathies are common genetic disorders of hemoglobin, which can be prevented by population screening and offering genetic counseling. In absence of population-based screening for hemoglobinopathies, the hospital-based diagnosis register provide idea about the extent of problem in the community. The present study was undertaken to find out the burden of hemoglobinopathies and spectrum of this disorders among the population who were screened in the hospital-based screening program. A record-basedanalysis of subjects who underwent screening for hemoglobinopathies in Burdwan Medical College and Hospital over a period of 3 years and 4 months revealed that overall 29.3% of subjects were positive for hemoglobinopathies. Beta thalassemia heterozygous was the most commonhemoglobinopathy in this region closely followed by hemoglobin E heterozygous. In view of high prevalence of hemoglobinopathies in this region, a routine premarital screening program is needed for identification and prevention of high-risk marriages.

  13. Cystic Fibrosis Colorectal Cancer Screening Consensus Recommendations.

    Science.gov (United States)

    Hadjiliadis, Denis; Khoruts, Alexander; Zauber, Ann G; Hempstead, Sarah E; Maisonneuve, Patrick; Lowenfels, Albert B

    2018-02-01

    Improved therapy has substantially increased survival of persons with cystic fibrosis (CF). But the risk of colorectal cancer (CRC) in adults with CF is 5-10 times greater compared to the general population, and 25-30 times greater in CF patients after an organ transplantation. To address this risk, the CF Foundation convened a multi-stakeholder task force to develop CRC screening recommendations. The 18-member task force consisted of experts including pulmonologists, gastroenterologists, a social worker, nurse coordinator, surgeon, epidemiologist, statistician, CF adult, and a parent. The committee comprised 3 workgroups: Cancer Risk, Transplant, and Procedure and Preparation. A guidelines specialist at the CF Foundation conducted an evidence synthesis February-March 2016 based on PubMed literature searches. Task force members conducted additional independent searches. A total of 1159 articles were retrieved. After initial screening, the committee read 198 articles in full and analyzed 123 articles to develop recommendation statements. An independent decision analysis evaluating the benefits of screening relative to harms and resources required was conducted by the Department of Public Health at Erasmus Medical Center, Netherlands using the Microsimulation Screening Analysis model from the Cancer Innervation and Surveillance Modeling Network. The task force included recommendation statements in the final guideline only if they reached an 80% acceptance threshold. The task force makes 10 CRC screening recommendations that emphasize shared, individualized decision-making and familiarity with CF-specific gastrointestinal challenges. We recommend colonoscopy as the preferred screening method, initiation of screening at age 40 years, 5-year re-screening and 3-year surveillance intervals (unless shorter interval is indicated by individual findings), and a CF-specific intensive bowel preparation. Organ transplant recipients with CF should initiate CRC screening

  14. School scoliosis screening programme-a systematic review.

    Science.gov (United States)

    Sabirin, J; Bakri, R; Buang, S N; Abdullah, A T; Shapie, A

    2010-12-01

    A systematic review on the effectiveness and cost-effectiveness of school scoliosis screening programme was carried out. A total of 248 relevant titles were identified, 117 abstracts were screened and 28 articles were included in the results. There was fair level of evidence to suggest that school scoliosis screening programme is safe, contributed to early detection and reduction of surgery. There was also evidence to suggest that school-based scoliosis screening programme is cost-effective. Based on the above review, screening for scoliosis among school children is recommended only for high risk group such as girls at twelve years of age.

  15. European position statement on lung cancer screening

    DEFF Research Database (Denmark)

    Oudkerk, Matthijs; Devaraj, Anand; Vliegenthart, Rozemarijn

    2017-01-01

    Lung cancer screening with low-dose CT can save lives. This European Union (EU) position statement presents the available evidence and the major issues that need to be addressed to ensure the successful implementation of low-dose CT lung cancer screening in Europe. This statement identified...... specific actions required by the European lung cancer screening community to adopt before the implementation of low-dose CT lung cancer screening. This position statement recommends the following actions: a risk stratification approach should be used for future lung cancer low-dose CT programmes...... need to set a timeline for implementing lung cancer screening....

  16. Screening in dense ionic fluids

    International Nuclear Information System (INIS)

    Tosi, M.P.

    1991-01-01

    There has been great progress in recent years in determining and understanding the structure of molten salts. I focus on molten alkali halides and discuss two main points concerning their liquid structure and its relationship with static electrical response in these dense ionic conductors. These are (i) the nature of screening and the related definitions and properties of the screening length and of the dielectric function, and (ii) developments in integral equations techniques for the evaluation of molten salt structure and static screening from given pair potentials. (author). 26 refs, 3 figs, 2 tabs

  17. BREAST CANCER SCREENING IN A RESOURCE POOR ...

    African Journals Online (AJOL)

    al rates of breast cancer, hence screening of asympto- matic, apparently healthy ... screening tools in women who attended free breast cancer screening exercise in a ..... signs of malignancy. www.appliedradiology.mobi/uploadedfiles/Issues/2.

  18. Mammography screening. Benefits, harms, and informed choice.

    Science.gov (United States)

    Jørgensen, Karsten Juhl

    2013-04-01

    The rationale for breast cancer screening with mammography is deceptively simple: catch it early and reduce mortality from the disease and the need for mastectomies. But breast cancer is a complex problem, and complex problems rarely have simple solutions. Breast screening brings forward the time of diagnosis only slightly compared to the lifetime of a tumour, and screen-detected tumours have a size where metastases are possible. A key question is if screening can prevent metastases, and if the screen-detected tumours are small enough to allow breast conserving surgery rather than mastectomy. A mortality reduction can never justify a medical intervention in its own right, but must be weighed against the harms. Overdiagnosis is the most important harm of breast screening, but has gained wider recognition only in recent years. Screening leads to the detection and treatment of breast cancers that would otherwise never have been detected because they grow very slowly or not at all and would not have been detected in the woman's lifetime in the absence of screening. Screening therefore turns women into cancer patients unnecessarily, with life-long physical and psychological harms. The debate about the justification of breast screening is therefore not a simple question of whether screening reduces breast cancer mortality. This dissertation quantifies the primary benefits and harms of screening mammography. Denmark has an unscreened "control group" because only two geographical regions offered screening over a long time-period, which is unique in an international context. This was used to study breast cancer mortality, overdiagnosis, and the use of mastectomies. Also, a systematic review of overdiagnosis in five other countries allowed us to show that about half of the screen-detected breast cancers are overdiagnosed. An effect on breast cancer mortality is doubtful in today's setting, and overdiagnosis causes an increase in the use of mastectomies. These findings are

  19. [Generalized neonatal screening based on laboratory tests].

    Science.gov (United States)

    Ardaillou, Raymond; Le Gall, Jean-Yves

    2006-11-01

    Implementation of a generalized screening program for neonatal diseases must obey precise rules. The disease must be severe, recognizable at an early stage, amenable to an effective treatment, detectable with a non expensive and widely applicable test; it must also be a significant public health problem. Subjects with positive results must be offered immediate treatment or prevention. All screening programs must be regularly evaluated. In France, since 1978, a national screening program has been organized by a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and supervised by the "Caisse nationale d'assurance maladie" and "Direction Générale de la Sante". Five diseases are now included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease (the latter only in at-risk newborns). Toxoplasmosis is a particular problem because only the children of mothers who were not tested during the pregnancy or who seroconverted are screened. Neonatal screening for phenylketonuria and hypothyrodism is unanimously recommended. Screening for congenital adrenal hyperplasia is approved in most countries. Cases of sickle cell disease and cystic fibrosis are more complex because--not all children who carry the mutations develop severe forms;--there is no curative treatment;--parents may become anxious, even though the phenotype is sometimes mild or even asymptomatic. Supporters of screening stress the benefits of early diagnosis (which extends the life expectancy of these children, particularly in the case of sickle cell disease), the fact that it opens up the possibility of prenatal screening of future pregnancies, and the utility of informing heterozygous carriers identified by familial screening. Neonatal screening for other diseases is under discussion. Indeed, technical advances such as tandem mass spectrometry make it possible to detect about 50

  20. The "DOC" screen: Feasible and valid screening for depression, Obstructive Sleep Apnea (OSA) and cognitive impairment in stroke prevention clinics.

    Science.gov (United States)

    Swartz, Richard H; Cayley, Megan L; Lanctôt, Krista L; Murray, Brian J; Cohen, Ashley; Thorpe, Kevin E; Sicard, Michelle N; Lien, Karen; Sahlas, Demetrios J; Herrmann, Nathan

    2017-01-01

    Post-stroke Depression, Obstructive sleep apnea (OSA) and Cognitive impairment ("DOC") are associated with greater mortality, worse recovery and poorer quality of life. Best practice recommendations endorse routine screening for each condition; yet, all are under-assessed, diagnosed and treated. We seek to determine the feasibility and validity of an integrated tool ("DOC" screen) to identify stroke clinic patients at high-risk of depression, OSA, and cognitive impairment. All consecutive new referrals to a regional Stroke Prevention Clinic who were English-speaking and non-aphasic were eligible to be screened. Time for screen completion was logged. DOC screen results were compared to the neuropsychological battery and polysomnogram assessments using a modified receiver operator characteristic and area under the curve analysis. Data is reported to conform to STARD guidelines. 1503 people were screened over 2 years. 89% of eligible patients completed the screen in 5 minutes or less (mean 4.2 minutes), less than half the time it takes to complete the Montreal Cognitive Assessment (MoCA). 437 people consented to detailed testing. Of those, 421 completed the Structured Clinical Interview for Depression within 3 months of screening, 387 completed detailed neuropsychological testing within 3 months, and 88 had overnight polysomnograms. Screening scores combined with demographic variables (age, sex, education, body mass index), had excellent validity compared to gold standard diagnoses: DOC-Mood AUC 0.90; DOC-Apnea AUC 0.80; DOC-Cog AUC 0.81. DOC screen scores can reliably categorize patients in to low-, intermediate- or high-risk groups for further action and can do so with comparable accuracy to more time-consuming screens. Systematic screening of depression, obstructive sleep apnea, and cognitive impairment in 5 minutes or less is feasible and valid in a high volume stroke clinic using the DOC screen. The DOC screen may facilitate improved identification and treatment

  1. Medical auditing of whole-breast screening ultrasonography.

    Science.gov (United States)

    Kim, Min Jung

    2017-07-01

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  2. Medical auditing of whole-breast screening ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jung [Dept. of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-07-15

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  3. Breast Cancer Screening, Mammography, and Other Modalities.

    Science.gov (United States)

    Fiorica, James V

    2016-12-01

    This article is an overview of the modalities available for breast cancer screening. The modalities discussed include digital mammography, digital breast tomosynthesis, breast ultrasonography, magnetic resonance imaging, and clinical breast examination. There is a review of pertinent randomized controlled trials, studies and meta-analyses which contributed to the evolution of screening guidelines. Ultimately, 5 major medical organizations formulated the current screening guidelines in the United States. The lack of consensus in these guidelines represents an ongoing controversy about the optimal timing and method for breast cancer screening in women. For mammography screening, the Breast Imaging Reporting and Data System lexicon is explained which corresponds with recommended clinical management. The presentation and discussion of the data in this article are designed to help the clinician individualize breast cancer screening for each patient.

  4. Breast cancer screening; cost-effective in practice?

    International Nuclear Information System (INIS)

    Koning, Harry J. de

    2000-01-01

    The main aim of national breast screening is a reduction in breast cancer mortality. The data on the reduction in breast cancer mortality from three (of the five) Swedish trials in particular gave rise to the expectation that the Dutch programme of 2-yearly screening for women aged 50-70 would produce a 16% reduction in the total population. In all likelihood, many of the years of life gained as a result of screening are enjoyed in good health. According to its critics the actual benefit that can be achieved from the national breast cancer screening programmes is overstated. Considerable benefits have recently been demonstrated in England and Wales. However, the fall was so considerable in such a relatively short space of time that screening (started in 1987) was thought to only have played a small part. As far as the Dutch screening programme is concerned it is still too early to reach any conclusions about a possible reduction in mortality. The first short-term results of the screening are favourable and as good as (or better than) expectations. In Swedish regions where mammographic screening was introduced, a 19% reduction in breast cancer mortality can be estimated at population level, and recently a 20% reduction was presented in the UK. In countries where women are expected to make appointments for screening themselves, the attendance figures are significantly lower and the quality of the process as a whole is sometimes poorer. The benefits of breast cancer screening need to be carefully balanced against the burden to women and to the health care system. Mass breast screening requires many resources and will be a costly service. Cost-effectiveness of a breast cancer screening programme can be estimated using a computer model. Published cost-effectiveness ratios may differ tremendously, but are often the result of different types of calculation, time periods considered, including or excluding downstream cost. The approach of simulation and estimation is here

  5. A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen

    Science.gov (United States)

    Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu

    2018-02-01

    Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.

  6. Estimating time and travel costs incurred in clinic based screening: flexible sigmoidoscopy screening for colorectal cancer.

    Science.gov (United States)

    Frew, E; Wolstenholme, J L; Atkin, W; Whynes, D K

    1999-01-01

    To identify the characteristics of mode of travel to screening clinics; to estimate the time and travel costs incurred in attending; to investigate whether such costs are likely to bias screening compliance. Twelve centres in the trial of flexible sigmoidoscopy screening for colorectal cancer, drawn from across Great Britain. Analysis of 3525 questionnaires completed by screening subjects while attending clinics. Information supplied included sociodemographic characteristics, modes of travel, expenses, activities foregone owing to attendance, and details of companions. More than 80% of subjects arrived at the clinics by car, and about two thirds were accompanied. On average, the clinic visit involved a 14.4 mile (22.8 km) round trip, requiring 130 minutes. Mean travel costs amounted to 6.10 Pounds per subject. The mean gross direct non-medical and indirect cost per subject amounted to 16.90 Pounds, and the mean overall gross cost per attendance was 22.40 Pounds. Compared with the Great Britain population as a whole, non-manual classes were more strongly represented, and the self employed less strongly represented, among the attendees. In relation to direct medical costs, the time and travel costs of clinic based screening can be substantial, may influence the overall cost effectiveness of a screening programme, and may deter potential subjects from attending.

  7. Studies Comparing Screen-Film Mammography and Full-Field Digital Mammography in Breast Cancer Screening: Updated Review

    International Nuclear Information System (INIS)

    Skaane, P.

    2009-01-01

    Full-field digital mammography (FFDM) has several potential benefits as compared with screen-film mammography (SFM) in mammography screening. Digital technology also opens for implementation of advanced applications, including computer-aided detection (CAD) and tomosynthesis. Phantom studies and experimental clinical studies have shown that FFDM is equal or slightly superior to SFM for detection and characterization of mammographic abnormalities. Despite obvious advantages, the conversion to digital mammography has been slower than anticipated, and not only due to higher costs. Until very recently, some countries did not even permit the use of digital mammography in breast cancer screening. The reason for this reluctant attitude was concern about lower spatial resolution and about using soft-copy reading. Furthermore, there was a lack of data supporting improved diagnostic accuracy using FFDM in a screening setting, since two pioneer trials both showed nonsignificantly lower cancer detection rate at FFDM. The 10 studies comparing FFDM and SFM in mammography screening published so far have shown divergent and rather conflicting results. Nevertheless, there is a rapid conversion to digital mammography in breast cancer screening in many western countries. The aim of this article is to give an updated review of these studies, discuss the conflicting findings, and draw some conclusions from the results

  8. A Targeted Approach for Congenital Cytomegalovirus Screening Within Newborn Hearing Screening.

    Science.gov (United States)

    Fowler, Karen B; McCollister, Faye P; Sabo, Diane L; Shoup, Angela G; Owen, Kris E; Woodruff, Julie L; Cox, Edith; Mohamed, Lisa S; Choo, Daniel I; Boppana, Suresh B

    2017-02-01

    Congenital cytomegalovirus (cCMV) infection remains a leading cause of childhood hearing loss. Currently universal CMV screening at birth does not exist in the United States. An alternative approach could be testing infants who do not pass their newborn hearing screening (NHS) for cCMV. This study was undertaken to evaluate whether a targeted approach will identify infants with CMV-related sensorineural hearing loss (SNHL). Infants born at 7 US medical centers received NHS and were also screened for cCMV while in the newborn nursery. Infants who tested positive for CMV received further diagnostic audiologic evaluations to identify or confirm hearing loss. Between 2007 and 2012, 99 945 newborns were screened for both hearing impairment and cCMV. Overall, 7.0% of CMV-positive infants did not pass NHS compared with 0.9% of CMV-negative infants (P CMV-infected infants who passed their NHS had SNHL confirmed by further evaluation during early infancy. NHS in this cohort identified 57% of all CMV-related SNHL that occurred in the neonatal period. A targeted CMV approach that tests newborns who fail their NHS identified the majority of infants with CMV-related SNHL at birth. However, 43% of the infants with CMV-related SNHL in the neonatal period and cCMV infants who are at risk for late onset SNHL were not identified by NHS. Copyright © 2017 by the American Academy of Pediatrics.

  9. Screening for Intimate Partner Violence in Orthopedic Patients: A Comparison of Three Screening Tools

    Science.gov (United States)

    Sprague, Sheila; Madden, Kim; Dosanjh, Sonia; Petrisor, Brad; Schemitsch, Emil H.; Bhandari, Mohit

    2012-01-01

    Accurately identifying victims of intimate partner violence (IPV) can be a challenge for clinicians and clinical researchers. Multiple instruments have been developed and validated to identify IPV in patients presenting to health care practitioners, including the Woman Abuse Screening Tool (WAST) and the Partner Violence Screen (PVS). The purpose…

  10. Developments in Colorectal Cancer Screening

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Colorectal Cancer Developments in Colorectal Cancer Screening Past Issues / Summer 2016 Table of ... at the National Cancer Institute, shared developments in colorectal cancer screening methods with NIH MedlinePlus magazine. What ...

  11. Miniature short hairpin RNA screens to characterize antiproliferative drugs.

    Science.gov (United States)

    Kittanakom, Saranya; Arnoldo, Anthony; Brown, Kevin R; Wallace, Iain; Kunavisarut, Tada; Torti, Dax; Heisler, Lawrence E; Surendra, Anuradha; Moffat, Jason; Giaever, Guri; Nislow, Corey

    2013-08-07

    The application of new proteomics and genomics technologies support a view in which few drugs act solely by inhibiting a single cellular target. Indeed, drug activity is modulated by complex, often incompletely understood cellular mechanisms. Therefore, efforts to decipher mode of action through genetic perturbation such as RNAi typically yields "hits" that fall into several categories. Of particular interest to the present study, we aimed to characterize secondary activities of drugs on cells. Inhibiting a known target can result in clinically relevant synthetic phenotypes. In one scenario, drug perturbation could, for example, improperly activate a protein that normally inhibits a particular kinase. In other cases, additional, lower affinity targets can be inhibited as in the example of inhibition of c-Kit observed in Bcr-Abl-positive cells treated with Gleevec. Drug transport and metabolism also play an important role in the way any chemicals act within the cells. Finally, RNAi per se can also affect cell fitness by more general off-target effects, e.g., via the modulation of apoptosis or DNA damage repair. Regardless of the root cause of these unwanted effects, understanding the scope of a drug's activity and polypharmacology is essential for better understanding its mechanism(s) of action, and such information can guide development of improved therapies. We describe a rapid, cost-effective approach to characterize primary and secondary effects of small-molecules by using small-scale libraries of virally integrated short hairpin RNAs. We demonstrate this principle using a "minipool" composed of shRNAs that target the genes encoding the reported protein targets of approved drugs. Among the 28 known reported drug-target pairs, we successfully identify 40% of the targets described in the literature and uncover several unanticipated drug-target interactions based on drug-induced synthetic lethality. We provide a detailed protocol for performing such screens and for

  12. Pathophysiology, risk factors, and screening methods for prediabetes in women with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Gourgari E

    2016-08-01

    Full Text Available Evgenia Gourgari,1 Elias Spanakis,2 Adrian Sandra Dobs3 1Division of Pediatric Endocrinology, Georgetown University School of Medicine, Washington, DC, 2Division of Endocrinology, University of Maryland School of Medicine, 3Department of Endocrinology, Johns Hopkins University School of Medicine, Baltimore, MD, USA Abstract: Polycystic ovary syndrome (PCOS is a syndrome associated with insulin resistance (IR, obesity, infertility, and increased cardiometabolic risk. This is a descriptive review of several mechanisms that can explain the IR among women with PCOS, other risk factors for the development of diabetes, and the screening methods used for the detection of glucose intolerance in women with PCOS. Few mechanisms can explain IR in women with PCOS such as obesity, insulin receptor signaling defects, and inhibition of insulin-mediated glucose uptake in adipocytes. Women with PCOS have additional risk factors for the development of glucose intolerance such as family history of diabetes, use of oral contraceptives, anovulation, and age. The Androgen Society in 2007 and the Endocrine Society in 2013 recommended using oral glucose tolerance test as a screening tool for abnormal glucose tolerance in all women with PCOS. The approach to detection of glucose intolerance among women with PCOS varies among health care providers. Large prospective studies are still needed for the development of guidelines with strong evidence. When assessing risk of future diabetes in women with PCOS, it is important to take into account the method used for screening as well as other risk factors that these women might have. Keywords: IR, OGTT, obesity, hyperandrogenism, anovulation, BMI, insulin resistance, PCOS

  13. Web-based newborn screening system for metabolic diseases: machine learning versus clinicians.

    Science.gov (United States)

    Chen, Wei-Hsin; Hsieh, Sheau-Ling; Hsu, Kai-Ping; Chen, Han-Ping; Su, Xing-Yu; Tseng, Yi-Ju; Chien, Yin-Hsiu; Hwu, Wuh-Liang; Lai, Feipei

    2013-05-23

    A hospital information system (HIS) that integrates screening data and interpretation of the data is routinely requested by hospitals and parents. However, the accuracy of disease classification may be low because of the disease characteristics and the analytes used for classification. The objective of this study is to describe a system that enhanced the neonatal screening system of the Newborn Screening Center at the National Taiwan University Hospital. The system was designed and deployed according to a service-oriented architecture (SOA) framework under the Web services .NET environment. The system consists of sample collection, testing, diagnosis, evaluation, treatment, and follow-up services among collaborating hospitals. To improve the accuracy of newborn screening, machine learning and optimal feature selection mechanisms were investigated for screening newborns for inborn errors of metabolism. The framework of the Newborn Screening Hospital Information System (NSHIS) used the embedded Health Level Seven (HL7) standards for data exchanges among heterogeneous platforms integrated by Web services in the C# language. In this study, machine learning classification was used to predict phenylketonuria (PKU), hypermethioninemia, and 3-methylcrotonyl-CoA-carboxylase (3-MCC) deficiency. The classification methods used 347,312 newborn dried blood samples collected at the Center between 2006 and 2011. Of these, 220 newborns had values over the diagnostic cutoffs (positive cases) and 1557 had values that were over the screening cutoffs but did not meet the diagnostic cutoffs (suspected cases). The original 35 analytes and the manifested features were ranked based on F score, then combinations of the top 20 ranked features were selected as input features to support vector machine (SVM) classifiers to obtain optimal feature sets. These feature sets were tested using 5-fold cross-validation and optimal models were generated. The datasets collected in year 2011 were used as

  14. Screening for retinopathy of prematurity in a large tertiary neonatal intensive care unit in Turkey: frequency and risk factors.

    Science.gov (United States)

    Sarikabadayi, Yusuf Unal; Aydemir, Ozge; Ozen, Zuhal Tunay; Aydemir, Cumhur; Tok, Levent; Oguz, Serife Suna; Erdeve, Omer; Uras, Nurdan; Dilmen, Ugur

    2011-12-01

    We aimed to determine applicable guidelines for screening of retinopathy of prematurity (ROP), and evaluate the contribution of risk factors for severe ROP. A prospective cohort study of neonates with a gestational age (GA) < 34 weeks or birth weight < 2000g who were admitted to the Neonatal Intensive Care Unit (NICU) of a tertiary level hospital was conducted. The study group was classified into three groups according to eye examination findings as no ROP, mild ROP and severe ROP. Of the 700 neonates screened, the frequencies of ROP for any stage and severe ROP were 32.7% and 3.1%, respectively. Laser photocoagulation was needed in 9.6% of neonates with ROP. None of the neonates with a GA ≥ 31 weeks required treatment. Any ROP was detected in 199 (53.6%) of the babies < 32 weeks (n = 371), 22 (5.9%) of whom were treated with laser photocoagulation. Independent risk factors for severe ROP in babies < 32 weeks GA were birth weight, duration of mechanical ventilation and patent ductus arteriosus (PDA). This is the largest prospective cohort study including infants younger than 34 weeks GA from Turkey. Our data which belongs to the last 1-year period shows lower incidence of severe ROP when compared to previous reports from Turkey. According to our data, screening babies smaller than 32 weeks GA or 1500g birth weight seems reasonable. In the presence of long duration of mechanical ventilation and PDA, screening should be intensified.

  15. Screening for Infectious Diseases among Newly Arrived Migrants in EU/EEA Countries—Varying Practices but Consensus on the Utility of Screening

    Directory of Open Access Journals (Sweden)

    Tommi Kärki

    2014-10-01

    Full Text Available Screening is one possible tool for monitoring infectious diseases among migrants. However, there is limited information on screening programmes targeted for newly arrived migrants in EU/EEA countries. Our aim was to investigate the implementation, practices and usefulness of these programmes. We conducted a survey among country experts from EU/EEA countries and Switzerland, asking whether their countries had implemented screening programmes. We also estimated the association between the implementation of these programmes and the rate of asylum-seekers in the population. Of the countries, 16 (59% had implemented screening programmes and 15 (56% had national guidelines. The rate of asylum-seekers was associated with implementation of screening programmes (p = 0.014. Screening was performed most often for tuberculosis; most commonly on holding level, and was targeted to specific migrant groups in over half of the countries performing screening. Twenty-five of all the country experts (96% considered screening among migrants useful, and 24 (92% would welcome EU level guidelines for screening. The implementation of screening programmes varied, and the practices were different among countries. Our survey suggests, that establishing EU level guidelines for screening would be useful, although they would have to take into account differences between individual countries.

  16. Risk Profiling May Improve Lung Cancer Screening

    Science.gov (United States)

    A new modeling study suggests that individualized, risk-based selection of ever-smokers for lung cancer screening may prevent more lung cancer deaths and improve the effectiveness and efficiency of screening compared with current screening recommendations

  17. Interval breast cancer characteristics before, during and after the transition from screen-film to full-field digital screening mammography.

    Science.gov (United States)

    van Bommel, Rob M G; Weber, Roy; Voogd, Adri C; Nederend, Joost; Louwman, Marieke W J; Venderink, Dick; Strobbe, Luc J A; Rutten, Matthieu J C; Plaisier, Menno L; Lohle, Paul N; Hooijen, Marianne J H; Tjan-Heijnen, Vivianne C G; Duijm, Lucien E M

    2017-05-05

    To determine the proportion of "true" interval cancers and tumor characteristics of interval breast cancers prior to, during and after the transition from screen-film mammography screening (SFM) to full-field digital mammography screening (FFDM). We included all women with interval cancers detected between January 2006 and January 2014. Breast imaging reports, biopsy results and breast surgery reports of all women recalled at screening mammography and of all women with interval breast cancers were collected. Two experienced screening radiologists reviewed the diagnostic mammograms, on which the interval cancers were diagnosed, as well as the prior screening mammograms and determined whether or not the interval cancer had been missed on the most recent screening mammogram. If not missed, the cancer was considered an occult ("true") interval cancer. A total of 442 interval cancers had been diagnosed, of which 144 at SFM with a prior SFM (SFM-SFM), 159 at FFDM with a prior SFM (FFDM-SFM) and 139 at FFDM with a prior FFDM (FFDM-FFDM). The transition from SFM to FFDM screening resulted in the diagnosis of more occult ("true") interval cancers at FFDM-SFM than at SFM-SFM (65.4% (104/159) versus 49.3% (71/144), P screened digitally for the second time (57.6% (80/139) at FFDM-FFDM versus 49.3% (71/144) at SFM-SFM). Tumor characteristics were comparable for the three interval cancer cohorts, except of a lower porportion (75.7 and 78.0% versus 67.2% af FFDM-FFDM, P cancers at FFDM with prior FFDM. An increase in the proportion of occult interval cancers is observed during the transition from SFM to FFDM screening mammography. However, this increase seems temporary and is no longer detectable after the second round of digital screening. Tumor characteristics and type of surgery are comparable for interval cancers detected prior to, during and after the transition from SFM to FFDM screening mammography, except of a lower proportion of invasive ductal cancers after the

  18. Galileon radiation from a spherical collapsing shell

    Energy Technology Data Exchange (ETDEWEB)

    Martín-García, Javier [Instituto de Física Teórica UAM/CSIC,C/ Nicolás Cabrera 15, E-28049 Madrid (Spain); Vázquez-Mozo, Miguel Á. [Instituto Universitario de Física Fundamental y Matemáticas (IUFFyM),Universidad de Salamanca, Plaza de la Merced s/n, E-37008 Salamanca (Spain)

    2017-01-17

    Galileon radiation in the collapse of a thin spherical shell of matter is analyzed. In the framework of a cubic Galileon theory, we compute the field profile produced at large distances by a short collapse, finding that the radiated field has two peaks traveling ahead of light fronts. The total energy radiated during the collapse follows a power law scaling with the shell’s physical width and results from two competing effects: a Vainshtein suppression of the emission and an enhancement due to the thinness of the shell.

  19. [Prostate cancer screening at Tatebayashi City in Gunma prefecture--results of screening with PSA alone between 2003 and 2005].

    Science.gov (United States)

    Nakamura, Toshiyuki; Etsunaga, Toru; Sasaki, Yasushi; Nitta, Takashi; Okugi, Yasunobu; Okazaki, Hiroshi; Katou, Nobuo; Yamamoto, Takumi; Suzuki, Kazuhiro

    2007-05-01

    Since 2003, a basic health checkup has involved prostate cancer screening with prostate specific antigen (PSA) alone. We investigated the results between 2003 and 2005. Among males aged over 50 years who underwent a basic health checkup, the subjects were those who desired prostate cancer screening. Cancer screening with PSA alone was performed; mass screening or individual screening in hospitals in the city. We employed PSA with respect to age stratification. On the primary screening, written informed consent regarding the analysis of the screening results was obtained. In 2003, there were 15,303 males aged over 50 years in Tatebayashi City. In 2003, 2004, and 2005, 11.8%, 12.2%, and 12.7% of the males underwent PSA screening, respectively. The rate of elevated PSA levels between 2003 and 2005 was 20.6%. Furthermore, 208, 165, and 179 males required secondary screening, and 80.3%, 61.2%, and 55.3% of the males underwent secondary screening, respectively. Of the males who underwent secondary screening, prostate biopsy was performed in 123 (73.2%), 54 (53.5%), and 38 (38.4%). Prostate cancer was detected in 60, 28, and 16 males, respectively. These values corresponded to 3.4%, 1.5%, and 0.8% of the males who underwent primary screening. The incidence of prostate cancer was 1.85% during the 3 years, and 3.2% in males who underwent the initial health checkup. Of 101 males in whom the stage was evaluated, the clinical stage was evaluated as B in 86 (85.1%), C in 9 (8.9%), and D in 6 (5.9%). Of the 101 males, endocrine therapy was performed in 46 (45.5%), surgery in 31 (30.7%), external irradiation in 5 (5.0%), and followup without treatment in 6 (5.9%). In addition, 7 (6.3%) desired treatment in another hospital, and 6 (5.9%) refused treatment. Prostate cancer was detected in 1.85% of males who underwent primary screening between 2003 and 2005. Of 101 males in whom the stage was evaluated, the clinical stage was evaluated as B in 86 (85.1%), and the early treatment of

  20. Evaluation of two-year Jewish genetic disease screening program in Atlanta: insight into community genetic screening approaches.

    Science.gov (United States)

    Shao, Yunru; Liu, Shuling; Grinzaid, Karen

    2015-04-01

    Improvements in genetic testing technologies have led to the development of expanded carrier screening panels for the Ashkenazi Jewish population; however, there are major inconsistencies in current screening practices. A 2-year pilot program was launched in Atlanta in 2010 to promote and facilitate screening for 19 Jewish genetic diseases. We analyzed data from this program, including participant demographics and outreach efforts. This retrospective analysis is based on a de-identified dataset of 724 screenees. Data were obtained through medical chart review and questionnaires and included demographic information, screening results, response to outreach efforts, and follow-up behavior and preferences. We applied descriptive analysis, chi-square tests, and logistic regression to analyze the data and compare findings with published literature. The majority of participants indicated that they were not pregnant or did not have a partner who was pregnant were affiliated with Jewish organizations and reported 100 % AJ ancestry. Overall, carrier frequency was 1 in 3.9. Friends, rabbis, and family members were the most common influencers of the decision to receive screening. People who were older, had a history of pregnancy, and had been previously screened were more likely to educate others (all p influencers who then encouraged screening in the target population. Educating influencers and increasing overall awareness were the most effective outreach strategies.