WorldWideScience

Sample records for vaginal pulse amplitude

  1. Pulse amplitude modulated chlorophyll fluorometer

    Science.gov (United States)

    Greenbaum, Elias; Wu, Jie

    2015-12-29

    Chlorophyll fluorometry may be used for detecting toxins in a sample because of changes in micro algae. A portable lab on a chip ("LOAC") based chlorophyll fluorometer may be used for toxin detection and environmental monitoring. In particular, the system may include a microfluidic pulse amplitude modulated ("PAM") chlorophyll fluorometer. The LOAC PAM chlorophyll fluorometer may analyze microalgae and cyanobacteria that grow naturally in source drinking water.

  2. Precise generator of stability amplitude pulses

    International Nuclear Information System (INIS)

    Zhuk, N.A.; Zdesenko, Yu.G.; Kuts, V.N.

    1989-01-01

    A generator of stability amplitude pulses, designed for stabilization of a low-noise semiconducting spectrometer, used in investigations of 76 Ge2β-decay, is described. The generator contains a permanent-voltage source, a storage element and a switch based on a Hg relay. A thermostatic source provides a relative voltage instability less than ±5x10 -6 per 80h (standard deviation). The Hg relay is placed into a separate thermostat. The relative instability of output generator pulse amplitude does not exceed ±1.5x10 -5 per 24h

  3. Pulse amplitude and frequency effects in a pulsed packed column

    International Nuclear Information System (INIS)

    Russell, S.H.

    1954-04-01

    A study has been made of the effect on the efficiency and capacity of applying pulses of varying amplitude and frequency to a packed column. In the efficiency studies, the maximum efficiency was obtained with a pulse having an amplitude of 3/8'' and a frequency of 140 cycles per minute. Under these conditions, the column was about five times as efficient as a simple packed column. Two general types of results were obtained in the capacity studies. Under certain conditions, the capacity increased over that of a simple packed column, but under others, it decreased. Some of the factors causing this were investigated but the fundamental reasons were not determined due to a lack of personnel for the necessary experiments. (author)

  4. Pulse amplitude and frequency effects in a pulsed packed column

    Energy Technology Data Exchange (ETDEWEB)

    Russell, S H

    1954-04-15

    A study has been made of the effect on the efficiency and capacity of applying pulses of varying amplitude and frequency to a packed column. In the efficiency studies, the maximum efficiency was obtained with a pulse having an amplitude of 3/8'' and a frequency of 140 cycles per minute. Under these conditions, the column was about five times as efficient as a simple packed column. Two general types of results were obtained in the capacity studies. Under certain conditions, the capacity increased over that of a simple packed column, but under others, it decreased. Some of the factors causing this were investigated but the fundamental reasons were not determined due to a lack of personnel for the necessary experiments. (author)

  5. The pulsed amplitude unit for the SLC

    International Nuclear Information System (INIS)

    Rolfe, J.; Browne, M.J.; Jobe, R.K.

    1987-02-01

    There is a recurring requirement in the SLC for the control of devices such as magnets, phase shifters, and attenuators on a beam-by-beam basis. The Pulsed Amplitude Unit (PAU) is a single width CAMAC module developed for this purpose. It provides digitally programmed analog output voltages on a beam-by-beam basis. Up to 32 preprogrammed values of output voltage are available from the single analog output of the module, and any of these values can be associated with any of the 256 possible SLC beam definitions. A 12-bit Analog-to-Digital Converter (ADC) digitizes an analog input signal at the appropriate beam time and stores it in a buffer memory. This feature is normally used to monitor the response of the device being controlled by the PAU at each beam time. Initial application of the PAU is a part of the system that controls the output of Klystrons in the SLC. The PAU combines several different functions in a single module. In order to accommodate these functions in a single width CAMAC module, field programmed logic is used extensively. Field Programmable Logic Arrays, Programmed Array Logic, and a Field Programmable Logic Sequencer are employed

  6. The pulsed amplitude unit for the SLC

    International Nuclear Information System (INIS)

    Rolfe, J.; Browne, M.J.; Jobe, R.K.

    1987-01-01

    There is a recurring requirement in the SLC for the control of devices such as magnets, phase shifters, and attenuators on a beam-by-beam basis. The Pulsed Amplitude Unit (PAU) is a single width CAMAC module developed for this purpose. It provides digitally programmed analog output voltages on a beam-by-beam basis. Up to 32 preprogrammed values of output voltage are available from the single analog output of the module, and any of these values can be associated with any of the 256 possible SLC beam definitions. A 12-bit Analog-to-Digital converter (ADC) digitizes an analog input signal at the appropriate beam time and stores it in a buffer memory. This feature is normally used to monitor the response of the device being controlled by the PAU at each beam time. Initial application of the PAU at is as part of the system that controls the output of Klystorns in the SLC. The PAU combines several different functions in a single module. In order to accommodate these functions in a single width CAMAC module, field programmed logic is used extensively. Field Programmable Logic Arrays, Programmed Array Logic, and a Field Programmable Logic Sequencer are employed

  7. A pulse amplitude dividing circuit for nuclear applications

    International Nuclear Information System (INIS)

    Ediss, C.; McQuarrie, S.A.

    1981-01-01

    A pulse dividing circuit has been developed to provide analogue and digital outputs proportional to the ratio of the amplitudes of two nuclear pulses. Input pulses ranging from 200 mV to 10 V may be processed by the device. The pulse dividing circuit has been successfully incorporated as part of a small gamma camera. (orig.)

  8. A pulse amplitude discriminator with very low-power consuming

    International Nuclear Information System (INIS)

    Deng Changming; Liu Zhengshan; Zhang Zhiyong; Cheng Chang

    2000-01-01

    A low-power pulse amplitude discriminator is described. The discriminator circuit is mainly composed of an integrated voltage comparator, MAX921, and owns the characters of very low-power and low operating voltage

  9. Finite-amplitude, pulsed, ultrasonic beams

    Science.gov (United States)

    Coulouvrat, François; Frøysa, Kjell-Eivind

    An analytical, approximate solution of the inviscid KZK equation for a nonlinear pulsed sound beam radiated by an acoustic source with a Gaussian velocity distribution, is obtained by means of the renormalization method. This method involves two steps. First, the transient, weakly nonlinear field is computed. However, because of cumulative nonlinear effects, that expansion is non-uniform and breaks down at some distance away from the source. So, in order to extend its validity, it is re-written in a new frame of co-ordinates, better suited to following the nonlinear distorsion of the wave profile. Basically, the nonlinear coordinate transform introduces additional terms in the expansion, which are chosen so as to counterbalance the non-uniform ones. Special care is devoted to the treatment of shock waves. Finally, comparisons with the results of a finite-difference scheme turn out favorable, and show the efficiency of the method for a rather large range of parameters.

  10. Pump pulse duration dependence of coherent phonon amplitudes in antimony

    Energy Technology Data Exchange (ETDEWEB)

    Misochko, O. V., E-mail: misochko@issp.ac.ru [Russian Academy of Sciences, Institute of Solid State Physics (Russian Federation)

    2016-08-15

    Coherent optical phonons of A{sub 1k} and E{sub k} symmetry in antimony have been studied using the femtosecond pump–probe technique. By varying the pump-pulse duration and keeping the probe duration constant, it was shown that the amplitude of coherent phonons of both symmetries exponentially decreases with increasing pulse width. It was found that the amplitude decay rate for the fully symmetric phonons with larger frequency is greater than that of the doubly degenerate phonons, whereas the frequency and lifetime for coherent phonons of both symmetries do not depend on the pump-pulse duration. Based on this data, the possibility of separation between dynamic and kinematic contributions to the generation mechanism of coherent phonons is discussed.

  11. Amplitude and phase control of attosecond light pulses

    International Nuclear Information System (INIS)

    Lopez-Martens, Rodrigo; Varju, Katalin; Johnsson, Per; Mauritsson, Johan; Persson, Anders; Svanberg, Sune; Wahlstroem, Claes-Goeran; L'Huillier, Anne; Mairesse, Yann; Salieres, Pascal; Gaarde, Mette B.; Schafer, Kenneth J.

    2005-01-01

    We report the generation, compression, and delivery on target of ultrashort extreme-ultraviolet light pulses using external amplitude and phase control. Broadband harmonic radiation is first generated by focusing an infrared laser with a carefully chosen intensity into a gas cell containing argon atoms. The emitted light then goes through a hard aperture and a thin aluminum filter that selects a 30-eV bandwidth around a 30-eV photon energy and synchronizes all of the components, thereby enabling the formation of a train of almost Fourier-transform-limited single-cycle 170 attosecond pulses. Our experiment demonstrates a practical method for synthesizing and controlling attosecond waveforms

  12. Adaptive pulse amplitude pulse width control of systems subject to Coulomb and viscous friction

    NARCIS (Netherlands)

    Wijdeven, van de J.J.M.; Singh, T.

    2003-01-01

    The focus of this paper is on adaptive controlof maneuvering rigid bodies in the presence offriction. The paper describes a simple techniquewhich include Pulse Amplitude and Pulse Widthmodulation to progressively move the system tothe desired final position. To account for uncertaintyin estimated

  13. Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude?

    Directory of Open Access Journals (Sweden)

    Gökhan Pekel

    2013-01-01

    Full Text Available Purpose. This study examines the effects of fundus fluorescein angiography (FFA procedure on ocular pulse amplitude (OPA and intraocular pressure (IOP. Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females were included in this cross-sectional case series. IOP and OPA were measured with the Pascal dynamic contour tonometer before and after 5 minutes of intravenous fluorescein dye injection. Results. Pre-FFA mean OPA value was  mmHg and post-FFA mean OPA value was  mmHg (. Pre-FFA mean IOP value was  mmHg and post-FFA mean IOP value was  mmHg (. Conclusion. Although both mean OPA and IOP values were decreased after FFA procedure, the difference was not statistically significant. This clinical trial is registered with Australian New Zealand Clinical Trials Registry number ACTRN12613000433707.

  14. A nuclear pulse amplitude acquisition system based on 80C31 single-chip microcomputer

    International Nuclear Information System (INIS)

    Zhao Xiuliang; Qu Guopu; Guo Lanying; Zhang Songbai

    1999-01-01

    A kind of multichannel nuclear pulse amplitude signal acquisition system is described, which is composed of pulse peak detector, integrated S/H circuit, A/D converter and 80C31 single-chip microcomputer

  15. Initial Breakdown Pulse Amplitudes in Intracloud and Cloud-to-Ground Lightning Flashes

    Science.gov (United States)

    Marshall, T. C.; Smith, E. M.; Stolzenburg, M.; Karunarathne, S.; Siedlecki, R. D., II

    2017-12-01

    This study analyzes the largest initial breakdown (IB) pulse in flashes from three storms in Florida. The study was motivated in part by the possibility that IB pulses of IC flashes may cause of terrestrial gamma-ray flashes (TGFs). The range-normalized, zero-to-peak amplitude of the largest IB pulse within each flash was determined along with its altitude, duration, and occurrence time in the flash. Appropriate data were available for 40 intracloud (IC) and 32 cloud-to-ground (CG) flashes. Histograms of the magnitude of the largest IB pulse amplitude by flash type were similar, with mean (median) values of 1.49 (1.05) V/m for IC flashes and -1.35 (-0.87) V/m for CG flashes. The mean amplitude of the largest IC IB pulses are substantially smaller (roughly an order of magnitude smaller) than the few known pulse amplitudes of TGF events and TGF candidate events. The largest IB pulse in 30 IC flashes showed a weak inverse relation between pulse amplitude and altitude. Amplitude of the largest IB pulse for 25 CG flashes showed no altitude correlation. Duration of the largest IB pulse in ICs averaged twice as long as in CGs (96 μs versus 46 μs); all of the CG durations were <100 μs. Among the ICs, there is a positive relation between largest IB pulse duration and amplitude; the linear correlation coefficient is 0.385 with outliers excluded. The largest IB pulse in IC flashes typically occurred at a longer time after the first IB pulse (average 4.1 ms) than was the case in CG flashes (average 0.6 ms). In both flash types, the largest IB pulse was the first IB pulse in about 30% of the cases.

  16. Vaginitis

    Science.gov (United States)

    ... change in discharge. What treatments are available for vaginal yeast infection? Yeast infections can be treated either by placing ... of organisms that are normally found in the vagina. Candidiasis: Also called yeast infection or moniliasis, a type ...

  17. All-fibre source of amplitude squeezed light pulses

    Energy Technology Data Exchange (ETDEWEB)

    Meissner, Markus; Marquardt, Christoph; Heersink, Joel; Gaber, Tobias; Wietfeld, Andre; Leuchs, Gerd; Andersen, Ulrik L [Institut fuer Optik, Information und Photonik, Max-Planck Forschungsgruppe Universitaet Erlangen-Nuernberg, Staudtstrasse 7/B2, 91058, Erlangen (Germany)

    2004-08-01

    An all-fibre source of amplitude squeezed solitons utilizing the self-phase modulation in an asymmetric Sagnac interferometer is experimentally demonstrated. The asymmetry of the interferometer is passively controlled by an integrated fibre coupler, allowing for the optimization of the noise reduction. We have carefully studied the dependence of the amplitude noise on the asymmetry and the power launched into the Sagnac interferometer. Qualitatively, we find good agreement between the experimental results, a semi-classical theory and earlier numerical calculations (Schmitt et al 1998 Phys. Rev. Lett. 81 2446). The stability and flexibility of this all-fibre source makes it particularly well suited to applications in quantum information science.

  18. Modeling of Pulses Having Arbitrary Amplitude and Frequency Modulation.

    Science.gov (United States)

    1980-03-01

    function, fi(t), has been discussed in great detail in Section II. The linearized amplitude modulation, 1(t), is given by: (IV-6) vo A +h( -) TO’ # where "A...10. LCDR Francis Martin Lunney, USN 6143 Gatsby Green Columbia, Maryland 21045 149

  19. A New Selective Harmonic Elimination Pulse- Width and Amplitude Modulation (SHEPWAM) for Drive Applications

    DEFF Research Database (Denmark)

    Ghoreishy, Hoda; Varjani, Ali Yazdian; Mohamadian, Mustafa

    2013-01-01

    Compared to the conventional selective harmonic elimination-pulse width modulation (SHE-PWM), the selective harmonic elimination-pulse width and amplitude modulation (SHE-PWAM) control strategy results in significant improvements in the performance of CHB inverters. This fact is due to considerin...

  20. Test research of consistency for amplitude calibration coefficients of pulsed electric field sensor

    International Nuclear Information System (INIS)

    Meng Cui; Guo Xiaoqiang; Chen Xiangyue; Nie Xin; Mao Congguang; Xiang Hui; Cheng Jianping

    2007-01-01

    The amplitude calibration of an electric field sensor is important in the measurement of electromagnetic pulse. In this paper, an arbitrary waveform generator (AWG) is used to generate multi-waveform electric field in the TEM cell and the dipole antenna pulsed electric field sensor is calibrated. In the frequency band of the sensor, the calibrated amplitude coefficients with different waveforms are identical. The coefficient derived from the TEM cell calibration system suits to the measurement of unknown electric field pulse within the frequency band. (authors)

  1. Direct generation of all-optical random numbers from optical pulse amplitude chaos.

    Science.gov (United States)

    Li, Pu; Wang, Yun-Cai; Wang, An-Bang; Yang, Ling-Zhen; Zhang, Ming-Jiang; Zhang, Jian-Zhong

    2012-02-13

    We propose and theoretically demonstrate an all-optical method for directly generating all-optical random numbers from pulse amplitude chaos produced by a mode-locked fiber ring laser. Under an appropriate pump intensity, the mode-locked laser can experience a quasi-periodic route to chaos. Such a chaos consists of a stream of pulses with a fixed repetition frequency but random intensities. In this method, we do not require sampling procedure and external triggered clocks but directly quantize the chaotic pulses stream into random number sequence via an all-optical flip-flop. Moreover, our simulation results show that the pulse amplitude chaos has no periodicity and possesses a highly symmetric distribution of amplitude. Thus, in theory, the obtained random number sequence without post-processing has a high-quality randomness verified by industry-standard statistical tests.

  2. Adjusting Pulse Amplitude During Transcutaneous Electrical Nerve Stimulation Does Not Provide Greater Hypoalgesia.

    Science.gov (United States)

    Bergeron-Vézina, Kayla; Filion, Camille; Couture, Chantal; Vallée, Élisabeth; Laroche, Sarah; Léonard, Guillaume

    2018-03-01

    Transcutaneous electrical nerve stimulation (TENS) is an electrotherapeutic modality commonly used in rehabilitation to relieve pain. Adjusting pulse amplitude (intensity) during TENS treatment has been suggested to overcome nerve habituation. However, it is still unclear if this procedure leads to greater hypoalgesia. The aim of this study was to determine if the hypoalgesic effect of TENS is greater when pulse amplitude is adjusted throughout the TENS treatment session in chronic low-back pain patients. Randomized double-blind crossover study. Recruitment and assessment were conducted at the Clinique universitaire de réadaptation de l'Estrie (CURE) of the Faculty of Medicine and Health Sciences of the Université de Sherbrooke. Twenty-one volunteers with chronic low-back pain were enrolled and completed this investigation. Each patient received two high-frequency TENS treatments on two separate sessions: (1) with adjustment of pulse amplitude and (2) without pulse amplitude adjustment. Pain intensity and unpleasantness were assessed before, during, and after TENS application with a 10 cm visual analog scale. Both TENS conditions (with and without adjustment of intensity) decreased pain intensity and unpleasantness when compared with baseline. No difference was observed between the two stimulation conditions for both pain intensity and unpleasantness. The current results suggest that adjustment of pulse amplitude during TENS application does not provide greater hypoalgesia in individuals with chronic low-back pain. Future studies are needed to confirm these findings in other pain populations.

  3. Control of broadband optically generated ultrasound pulses using binary amplitude holograms.

    Science.gov (United States)

    Brown, Michael D; Jaros, Jiri; Cox, Ben T; Treeby, Bradley E

    2016-04-01

    In this work, the use of binary amplitude holography is investigated as a mechanism to focus broadband acoustic pulses generated by high peak-power pulsed lasers. Two algorithms are described for the calculation of the binary holograms; one using ray-tracing, and one using an optimization based on direct binary search. It is shown using numerical simulations that when a binary amplitude hologram is excited by a train of laser pulses at its design frequency, the acoustic field can be focused at a pre-determined distribution of points, including single and multiple focal points, and line and square foci. The numerical results are validated by acoustic field measurements from binary amplitude holograms, excited by a high peak-power laser.

  4. Ocular pulse amplitude after panretinal photocoagulation in normotensive eyes with proliferative diabetic retinopathy.

    Science.gov (United States)

    Bozic, Marija M; Karadzic, Jelena B; Kovacevic, Igor M; Marjanovic, Ivan S

    2017-06-26

    To assess the effect of panretinal laser photocoagulation on ocular pulse amplitude (OPA) in normotensive eyes with proliferative diabetic retinopathy. Prospectively, we performed unilateral argon laser panretinal photocoagulation (PRP) in 30 patients with diabetes mellitus type II and previously untreated bilateral proliferative diabetic retinopathy. Before and 7 and 30 days after the treatment, OPA was measured using dynamic contour tonometer. Compared with the untreated contralateral eyes, laser photocoagulation led to a reduction of OPA. Ocular pulse amplitude did not significantly differ in photocoagulated eyes 7 days after the treatment, but there was a significant difference in OPA 30 days after the treatment. The decrease in OPA values was 15% 7 days after PRP and 40% 30 days after PRP. Ocular pulse amplitude reduction after PRP indirectly informs us about choriocapillary closure, already reported in previous studies.

  5. Cognitive-Behavioral Therapy versus Temporal Pulse Amplitude Biofeedback Training for Recurrent Headache

    Science.gov (United States)

    Martin, Paul R.; Forsyth, Michael R.; Reece, John

    2007-01-01

    Sixty-four headache sufferers were allocated randomly to cognitive-behavioral therapy (CBT), temporal pulse amplitude (TPA) biofeedback training, or waiting-list control. Fifty-one participants (14M/37F) completed the study, 30 with migraine and 21 with tension-type headache. Treatment consisted of 8, 1-hour sessions. CBT was highly effective,…

  6. The design of multi-channel pulse amplitude analyzer based on ARM micro controller

    International Nuclear Information System (INIS)

    Li Hai; Li Xiang; Liu Caixue

    2010-01-01

    It introduces the design of multi-channel pulse amplitude analyzer based on embedded ARM micro-controller. The embedded and real-time system μC/OS-II builds up the real-time and stability of the system and advances the integration. (authors)

  7. Telemetry Standards, RCC Standard 106-17, Annex A.1, Pulse Amplitude Modulation Standards

    Science.gov (United States)

    2017-07-01

    Standard 106-17 Annex A.1, July 2017 A.1-iii Acronyms dB decibel FM frequency modulation IF intermediate frequency PAM pulse amplitude...premodulation filter when employed. b. One-fifth of the intermediate frequency (IF) bandwidth (3 dB points) selected from the IF bandwidths listed in

  8. Analog Amplitude Modulation of a High Voltage, Solid State Inductive Adder, Pulse Generator Using MOSFETS

    International Nuclear Information System (INIS)

    Gower, E J; Sullivan, J S

    2002-01-01

    High voltage, solid state, inductive adder, pulse generators have found increasing application as fast kicker pulse modulators for charged particle beams. The solid state, inductive adder, pulse generator is similar in operation to the linear induction accelerator. The main difference is that the solid state, adder couples energy by transformer action from multiple primaries to a voltage summing stalk, instead of an electron beam. Ideally, the inductive adder produces a rectangular voltage pulse at the load. In reality, there is usually some voltage variation at the load due to droop on primary circuit storage capacitors, or, temporal variations in the load impedance. Power MOSFET circuits have been developed to provide analog modulation of the output voltage amplitude of a solid state, inductive adder, pulse generator. The modulation is achieved by including MOSFET based, variable subtraction circuits in the multiple primary stack. The subtraction circuits can be used to compensate for voltage droop, or, to tailor the output pulse amplitude to provide a desired effect in the load. Power MOSFET subtraction circuits have been developed to modulate short, temporal (60-400 ns), voltage and current pulses. MOSFET devices have been tested up to 20 amps and 800 Volts with a band pass of 50 MHz. An analog modulation cell has been tested in a five cell high, voltage adder stack

  9. Numerical calculation of spin echo amplitude in pulsed NMR: effects of quadrupole interaction

    International Nuclear Information System (INIS)

    Sobral, R.R.

    1986-01-01

    The spin echo obtained by nuclear magnetic resonance, in systems which atomic nuclei interact with magnetic fields and electric field gradients, present oscillations in function of the time interval between two excitations pulses. Using the density matrix formalism, the amplitudes of these echo is calculated, analytically. In this work, echo amplitudes obtained under different excitation conditions for nuclei of different nuclear spin values are calculated. The numerical results are compared with disposable analytical solutions. Applications of this method to the case of electric field gradient without axial symmetry were studied. Within the used approximation limits, an expression for attnuation of oscillatory behaviour of echo amplitude in function of the time interval between experimentally observed pulses was obtained. (M.C.K.) [pt

  10. The neuronal response to electrical constant-amplitude pulse train stimulation: additive Gaussian noise.

    Science.gov (United States)

    Matsuoka, A J; Abbas, P J; Rubinstein, J T; Miller, C A

    2000-11-01

    Experimental results from humans and animals show that electrically evoked compound action potential (EAP) responses to constant-amplitude pulse train stimulation can demonstrate an alternating pattern, due to the combined effects of highly synchronized responses to electrical stimulation and refractory effects (Wilson et al., 1994). One way to improve signal representation is to reduce the level of across-fiber synchrony and hence, the level of the amplitude alternation. To accomplish this goal, we have examined EAP responses in the presence of Gaussian noise added to the pulse train stimulus. Addition of Gaussian noise at a level approximately -30 dB relative to EAP threshold to the pulse trains decreased the amount of alternation, indicating that stochastic resonance may be induced in the auditory nerve. The use of some type of conditioning stimulus such as Gaussian noise may provide a more 'normal' neural response pattern.

  11. Neurokinin B receptor antagonism decreases luteinising hormone pulse frequency and amplitude and delays puberty onset in the female rat.

    Science.gov (United States)

    Li, S Y; Li, X F; Hu, M H; Shao, B; Poston, L; Lightman, S L; O'Byrne, K T

    2014-08-01

    The neural mechanisms controlling puberty onset remain enigmatic. Humans with loss of function mutations in TAC3 or TACR3, the genes encoding neurokinin B (NKB) or its receptor, neurokinin-3 receptor (NK3R), respectively, present with severe congenital gonadotrophin deficiency and pubertal failure. Animal studies have shown ambiguous actions of NKB-NK3R signalling with respect to controlling puberty onset. The present study aimed to determine the role of endogenous NKB-NK3R signalling in the control of pulsatile luteinising hormone (LH) secretion and the timing of puberty onset, and also whether precocious pubertal onset as a result of an obesogenic diet is similarly regulated by this neuropeptide system. Prepubertal female rats, chronically implanted with i.c.v. cannulae, were administered SB222200, a NK3R antagonist, or artificial cerebrospinal fluid via an osmotic mini-pump for 14 days. SB222200 significantly delayed the onset of vaginal opening and first oestrus (as markers of puberty) compared to controls in both normal and high-fat diet fed animals. Additionally, serial blood sampling, via chronic indwelling cardiac catheters, revealed that the increase in LH pulse frequency was delayed and that the LH pulse amplitude was reduced in response to NK3R antagonism, regardless of dietary status. These data suggest that endogenous NKB-NK3R signalling plays a role in controlling the timing of puberty and the associated acceleration of gonadotrophin-releasing hormone pulse generator frequency in the female rat. © 2014 British Society for Neuroendocrinology.

  12. General theory for thermal pulses of finite amplitude in nuclear shell-burnings

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, D [Tokyo Univ. (Japan). Coll. of General Education; Fujimoto, M Y

    1978-09-01

    Theory for thermal pulses of nuclear shell-burning is advanced to include the case of finite amplitude. The aims are to predict the progress of thermal pulse quantitatively and to obtain the peak values of the temperature and nuclear energy generation rate without making detailed numerical computation of stellar structure. In order to attain them the physical processes involved in the progress of the pulse are clarified using the concepts of the flatness of the shell source, which destabilizes nuclear burning, and the effect of radiation pressure, which stabilizes it. It is shown that the progress of the pulse can be predicted quantitatively when the pressure and the gravitational potential of the burning shell are specified for the onset stage of the pulse. The pulse height is determined mainly by the initial pressure; the higher initial pressure results in the higher pulse. Mass dependence is also obtained by approximating the gravitational potential by that of white dwarfs. The initial pressure is the quantity which is determined in the course of evolution preceding the pulse. The theory is shown to give a satisfactory agreement with numerical computations for a wide variety of the preceding evolutions, i.e., both for the case of the core in red giant stars and of the accreting white dwarfs.

  13. Pulsed laser manipulation of an optically trapped bead: Averaging thermal noise and measuring the pulsed force amplitude

    DEFF Research Database (Denmark)

    Lindballe, Thue Bjerring; Kristensen, Martin V. G.; Keiding, Søren Rud

    2013-01-01

    An experimental strategy for post-eliminating thermal noise on position measurements of optically trapped particles is presented. Using a nanosecond pulsed laser, synchronized to the detection system, to exert a periodic driving force on an optically trapped 10 polystyrene bead, the laser pulse-bead...... interaction is repeated hundreds of times. Traces with the bead position following the prompt displacement from equilibrium, induced by each laser pulse, are averaged and reveal the underlying deterministic motion of the bead, which is not visible in a single trace due to thermal noise. The motion of the bead...... is analyzed from the direct time-dependent position measurements and from the power spectrum. The results show that the bead is on average displaced 208 nm from the trap center and exposed to a force amplitude of 71 nanoNewton, more than five orders of magnitude larger than the trapping forces. Our...

  14. Changes in mean plasma ACTH reflect changes in amplitude and frequency of secretory pulses

    International Nuclear Information System (INIS)

    Carnes, M.; Lent, S.J.; Erisman, S.; Feyzi, J.

    1988-01-01

    ACTH is secreted in an episodic manner from the anterior pituitary. Unanesthetized rats with indwelling jugular and femoral venous cannulae were continuously bled and simultaneously infused with isotonic fluid by peristaltic pump. Two-minute blood samples were collected for up to five hours in 8 male rats. ACTH was measured by radioimmunoassay. The resulting time series were analyzed for significant secretory pulses with the PULSAR program. Elevations or declines in mean plasma ACTH levels were associated with significant changes in amplitude and frequency of secretory pulses

  15. Efficient amplitude-modulated pulses for triple- to single-quantum coherence conversion in MQMAS NMR.

    Science.gov (United States)

    Colaux, Henri; Dawson, Daniel M; Ashbrook, Sharon E

    2014-08-07

    The conversion between multiple- and single-quantum coherences is integral to many nuclear magnetic resonance (NMR) experiments of quadrupolar nuclei. This conversion is relatively inefficient when effected by a single pulse, and many composite pulse schemes have been developed to improve this efficiency. To provide the maximum improvement, such schemes typically require time-consuming experimental optimization. Here, we demonstrate an approach for generating amplitude-modulated pulses to enhance the efficiency of the triple- to single-quantum conversion. The optimization is performed using the SIMPSON and MATLAB packages and results in efficient pulses that can be used without experimental reoptimisation. Most significant signal enhancements are obtained when good estimates of the inherent radio-frequency nutation rate and the magnitude of the quadrupolar coupling are used as input to the optimization, but the pulses appear robust to reasonable variations in either parameter, producing significant enhancements compared to a single-pulse conversion, and also comparable or improved efficiency over other commonly used approaches. In all cases, the ease of implementation of our method is advantageous, particularly for cases with low sensitivity, where the improvement is most needed (e.g., low gyromagnetic ratio or high quadrupolar coupling). Our approach offers the potential to routinely improve the sensitivity of high-resolution NMR spectra of nuclei and systems that would, perhaps, otherwise be deemed "too challenging".

  16. Numerical Solution of the Kzk Equation for Pulsed Finite Amplitude Sound Beams in Thermoviscous Fluids

    Science.gov (United States)

    Lee, Yang-Sub

    A time-domain numerical algorithm for solving the KZK (Khokhlov-Zabolotskaya-Kuznetsov) nonlinear parabolic wave equation is developed for pulsed, axisymmetric, finite amplitude sound beams in thermoviscous fluids. The KZK equation accounts for the combined effects of diffraction, absorption, and nonlinearity at the same order of approximation. The accuracy of the algorithm is established via comparison with analytical solutions for several limiting cases, and with numerical results obtained from a widely used algorithm for solving the KZK equation in the frequency domain. The time domain algorithm is used to investigate waveform distortion and shock formation in directive sound beams radiated by pulsed circular piston sources. New results include predictions for the entire process of self-demodulation, and for the effect of frequency modulation on pulse envelope distortion. Numerical results are compared with measurements, and focused sources are investigated briefly.

  17. Isentropic/shock compression and recovery methodology for materials using high-amplitude laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Maddox, B.R., E-mail: maddox3@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Park, H.-S., E-mail: park1@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Lu, C.-H., E-mail: chiahuilu@gmail.com [University of California, 9500 Gilman Drive, La Jolla, San Diego, CA 92093 (United States); Remington, B.A., E-mail: remington2@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Prisbrey, S., E-mail: prisbrey1@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Kad, B., E-mail: bkad@ucsd.edu [University of California, 9500 Gilman Drive, La Jolla, San Diego, CA 92093 (United States); Luo, R., E-mail: luorwga@gmail.com [General Atomics, 3483 Dunhill Street, San Diego, CA 92121-1200 (United States); Meyers, M.A., E-mail: mameyers@eng.ucsd.edu [University of California, 9500 Gilman Drive, La Jolla, San Diego, CA 92093 (United States)

    2013-08-20

    Abstarct: A new method of subjecting samples to high-amplitude laser pulses with durations in the ns range and recovering them for characterization is presented. It is applied to tantalum monocrystals and nanocrystals that are subjected to controlled and prescribed ramp loading configurations, creating a quasi-isentropic loading in the front that is retained up to 40 μm into the specimen. This is enabled by the use of a reservoir into which six laser beams impinge simultaneously, thereby creating plasma in a reservoir, from which the pulse is launched into the metal. This technique enables, with proper wave trapping devices, the recovery of the specimens for subsequent characterization. Successful experiments conducted in the Laboratory for Laser Energetics, U. of Rochester, generated pressure pulses with initial amplitudes ranging from 15 to 110 GPa and initial durations of ∼3 ns. The quasi-isotropic loading minimizes thermal effects at the front surface. The compression history of the recovered samples is measured using velocity interferometry from an Al-coated LiF witness target on the same shot driven by a separate, but equivalent set of laser beams. These experimental measurements are compared with computations using a radiation hydrodynamics code. Recovered samples are investigated using optical, scanning, and transmission electron microscopy. The laser damage to the surface is characterized.

  18. Pulse-amplitude modulation of optical injection-locked quantum-dot lasers

    Science.gov (United States)

    Zhou, Yue-Guang; Wang, Cheng

    2018-02-01

    This work theoretically investigates the four-level pulse-amplitude modulation characteristics of quantum dot lasers subject to optical injection. The rate equation model takes into account carrier dynamics in the carrier reservoir, in the excited state, and in the ground state, as well as photon dynamics and phase dynamics of the electric field. It is found that the optical injection significantly improves the eye diagram quality through suppressing the relaxation oscillation, while the extinction ratio is reduced as well. In addition, both the adiabatic chirp and the transient chirp of the signal are substantially suppressed.

  19. Improving quality of laser scanning data acquisition through calibrated amplitude and pulse deviation measurement

    Science.gov (United States)

    Pfennigbauer, Martin; Ullrich, Andreas

    2010-04-01

    Newest developments in laser scanner technologies put surveyors in the position to comply with the ever increasing demand of high-speed, high-accuracy, and highly reliable data acquisition from terrestrial, mobile, and airborne platforms. Echo digitization in pulsed time-of-flight laser ranging has demonstrated its superior performance in the field of bathymetry and airborne laser scanning for more than a decade, however at the cost of somewhat time consuming off line post processing. State-of-the-art online waveform processing as implemented in RIEGL's V-Line not only saves users post-processing time to obtain true 3D point clouds, it also adds the assets of calibrated amplitude and reflectance measurement for data classification and pulse deviation determination for effective and reliable data validation. We present results from data acquisitions in different complex target situations.

  20. Generator of pulses with the nanosecond duration and accurate amplitude using the digital control in the CAMAC standard

    International Nuclear Information System (INIS)

    Basiladze, S.G.; Nguen Kuang Min'

    1980-01-01

    A generator of square-wave fine-amplitude nanosecond pulses is described. The generator is primarily intended for checking the performances of fast electronics analog-to-digital units with the help of a computer. In addition to digital control the pulse amplitude can be controlled manually or by the external voltage. Basic circuits of main generator assemblies: a triggering circuit, transistor key and digital-to-analog converter are given. Output pulses produced by the generator have the following parameters: the amplitude from - 0.15 to - 10 V (smooth or gradual, with a minimum step of 5 mV), the rising and decay pulse times approximately 2 ns, the maximum repetition frequency 10 kHz, the control linearity at a pulse duration of more than 50 ns 0.15%. A double-width CAMAC cell accomodates two generators

  1. Large amplitude dynamics of micro-/nanomechanical resonators actuated with electrostatic pulses

    International Nuclear Information System (INIS)

    Juillard, J.; Bonnoit, A.; Avignon, E.; Hentz, S.; Colinet, E.

    2010-01-01

    In the field of resonant nano-electro-mechanical system (NEMS) design, it is a common misconception that large-amplitude motion, and thus large signal-to-noise ratio, can only be achieved at the risk of oscillator instability. In the present paper, we show that very simple closed-loop control schemes can be used to achieve stable large-amplitude motion of a resonant structure even when jump resonance (caused by electrostatic softening or Duffing hardening) is present in its frequency response. We focus on the case of a resonant accelerometer sensing cell, consisting of a nonlinear clamped-clamped beam with electrostatic actuation and detection, maintained in an oscillation state with pulses of electrostatic force that are delivered whenever the detected signal (the position of the beam) crosses zero. We show that the proposed feedback scheme ensures the stability of the motion of the beam much beyond the critical Duffing amplitude and that, if the parameters of the beam are correctly chosen, one can achieve almost full-gap travel range without incurring electrostatic pull-in. These results are illustrated and validated with transient simulations of the nonlinear closed-loop system.

  2. Digital pulse processing techniques for high resolution amplitude measurement of radiation detector

    International Nuclear Information System (INIS)

    Singhai, P.; Roy, A.; Dhara, P.; Chatterjee, S.

    2012-01-01

    The digital pulse processing techniques for high resolution amplitude measurement of radiation detector pulse is an effective replacement of expensive and bulky analog processing as the digital domain offers higher channel density and at the same time it is cheaper. We have demonstrated a prototype digital setup with highspeed sampling ADC with sampling frequency of 80-125 MHz followed by series of IIR filters for pulse shaping in a trigger-less acquisition mode. The IIR filters, peak detection algorithm and the data write-out logic was written on VHDL and implemented on FPGA. We used CAMAC as the read out platform. In conjunction with the full hardware implementation we also used a mixed platform with VME digitizer card with raw-sample read out using C code. The rationale behind this mixed platform is to test out various filter algorithms quickly on C and also to benchmark the performance of the chip level ADCs against the standard commercial digitizer in terms of noise or resolution. The paper describes implementation of both the methods with performance obtained in both the methods. (author)

  3. Effect of heat-induced pain stimuli on pulse transit time and pulse wave amplitude in healthy volunteers.

    Science.gov (United States)

    van Velzen, Marit H N; Loeve, Arjo J; Kortekaas, Minke C; Niehof, Sjoerd P; Mik, Egbert G; Stolker, Robert J

    2016-01-01

    Pain is commonly assessed subjectively by interpretations of patient behaviour and/or reports from patients. When this is impossible the availability of a quantitative objective pain assessment tool based on objective physiological parameters would greatly benefit clinical practice and research beside the standard self-report tests. Vasoconstriction is one of the physiological responses to pain. The aim of this study was to investigate whether pulse transit time (PTT) and pulse wave amplitude (PWA) decrease in response to this vasoconstriction when caused by heat-induced pain. The PTT and PWA were measured in healthy volunteers, on both index fingers using photoplethysmography and electrocardiography. Each subject received 3 heat-induced pain stimuli using a Temperature-Sensory Analyzer thermode block to apply a controlled, increasing temperature from 32.0 °C to 50.0 °C to the skin. After reaching 50.0 °C, the thermode was immediately cooled down to 32.0 °C. The study population was divided into 2 groups with a time-interval between the stimuli 20s or 60s. The results showed a significant (p  Heat-induced pain causes a decrease of PTT and PWA. Consequently, it is expected that, in the future, PTT and PWA may be applied as objective indicators of pain, either beside the standard self-report test, or when self-report testing is impossible.

  4. Impact of non-white noises in pulse amplitude measurements: a time-domain approach

    International Nuclear Information System (INIS)

    Pullia, A.

    1998-01-01

    The contribution of the 1/f-noise to the spectral line broadening in pulse amplitude measurements is derived with a time-domain analysis. The known time-domain relationships which provide the contributions of the series and parallel white noises are generalised for the case of 1/f and other typical non-white noises, by using the fractional derivative of either the system impulse response (time-invariant linear filters) or its weight function folded (time-variant linear filters). It is shown that a time-domain approach is also effective to determine the contribution of Lorentzian noises. A simple rule suitable to derive numerically the fractional derivative is given, which permits to calculate the effect of non-white noises even when the filter impulse response is not known analytically but only in sampled form. (orig.)

  5. Differential Amplitude Pulse-Position Modulation for Indoor Wireless Optical Communications

    Directory of Open Access Journals (Sweden)

    Sethakaset Ubolthip

    2005-01-01

    Full Text Available We propose a novel differential amplitude pulse-position modulation (DAPPM for indoor optical wireless communications. DAPPM yields advantages over PPM, DPPM, and DH-PIM in terms of bandwidth requirements, capacity, and peak-to-average power ratio (PAPR. The performance of a DAPPM system with an unequalized receiver is examined over nondispersive and dispersive channels. DAPPM can provide better bandwidth and/or power efficiency than PAM, PPM, DPPM, and DH-PIM depending on the number of amplitude levels and the maximum length of a symbol. We also show that, given the same maximum length, DAPPM has better bandwidth efficiency but requires about and more power than PPM and DPPM, respectively, at high bit rates over a dispersive channel. Conversely, DAPPM requires less power than DH-PIM . When the number of bits per symbol is the same, PAM requires more power, and DH-PIM less power, than DAPPM. Finally, it is shown that the performance of DAPPM can be improved with MLSD, chip-rate DFE, and multichip-rate DFE.

  6. Quasi-periodic Pulse Amplitude Modulation in the Accreting Millisecond Pulsar IGR J00291+5934

    Energy Technology Data Exchange (ETDEWEB)

    Bult, Peter [Astrophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Doesburgh, Marieke van; Klis, Michiel van der [Anton Pannekoek Institute, University of Amsterdam, Postbus 94249, 1090 GE Amsterdam (Netherlands)

    2017-08-20

    We introduce a new method for analyzing the aperiodic variability of coherent pulsations in accreting millisecond X-ray pulsars (AMXPs). Our method involves applying a complex frequency correction to the time-domain light curve, allowing for the aperiodic modulation of the pulse amplitude to be robustly extracted in the frequency domain. We discuss the statistical properties of the resulting modulation spectrum and show how it can be correlated with the non-pulsed emission to determine if the periodic and aperiodic variability are coupled processes. Using this method, we study the 598.88 Hz coherent pulsations of the AMXP IGR J00291+5934 as observed with the Rossi X-ray Timing Explorer and XMM-Newton . We demonstrate that our method easily confirms the known coupling between the pulsations and a strong 8 mHz quasi-periodic oscillation (QPO) in XMM-Newton observations. Applying our method to the RXTE observations, we further show, for the first time, that the much weaker 20 mHz QPO and its harmonic are also coupled with the pulsations. We discuss the implications of this coupling and indicate how it may be used to extract new information on the underlying accretion process.

  7. Quasi-Periodic Pulse Amplitude Modulation in the Accreting Millisecond Pulsar IGR J00291+5934

    Science.gov (United States)

    Bult, Peter; van Doesburgh, Marieke; van der Klis, Michiel

    2017-01-01

    We introduce a new method for analyzing the a periodic variability of coherent pulsations in accreting millisecond X-ray pulsars (AMXPs). Our method involves applying a complex frequency correction to the time-domain lightcurve, allowing for the aperiodic modulation of the pulse amplitude to be robustly extracted in the frequency domain. We discuss the statistical properties of the resulting modulation spectrum and show how it can be correlated with the non-pulsed emission to determine if the periodic and a periodic variability are coupled processes. Using this method, we study the 598.88 Hz coherent pulsations of the AMXP IGR J00291+5934 as observed with the Rossi X-ray Timing Explorer and XMM-Newton. We demonstrate that our method easily confirms the known coupling between the pulsations and a strong 8 mHz quasi-periodic oscillation (QPO) in XMM-Newton observations. Applying our method to the RXTE observations, we further show, for the first time, that the much weaker 20 mHz QPO and its harmonic are also coupled with the pulsations. We discuss the implications of this coupling and indicate how it may be used to extract new information on the underlying accretion process.

  8. Pulse-amplitude multipliers using logarithmic amplitude-to-time conversion; Amplificateurs d'impulsions utilisant une conversion logarithmique temps-amplitude; Ob umnozhitelyakh amplitudy impul'sov s ispol'zovaniem logarifmicheskogo preobrazovaniya amplitudy vo vremya; Multiplicadores de amplitud de impulso usando una conversion logaritmica de amplitud en tiempo

    Energy Technology Data Exchange (ETDEWEB)

    Konrad, M [Institut Rudjer Boskovic, Zagreb, Yugoslavia (Croatia)

    1962-04-15

    The accuracy and limitations of multipliers based on logarithmic amplitude-to-time conversion using RC pulse stretchers are discussed with respect to their application for determining whether the amplitude product of two coincident pulses has a given value. Some possible circuits are given. (author) [French] L'auteur etudie la precision et les limitations des amplificateurs fondes sur la conversion logarithmique temps-amplitude et utilisant des allongeurs d'impulsions RC, afin d'etablir si ces appareils peuvent servir a determiner la valeur du produit des amplitudes de deux impulsions coincidentes. Il decrit en outre plusieurs circuits possibles. (author) [Spanish] La memoria discute la precision y limitaciones de los multiplicadores basados en la conversion logaritmica de amplitud en tiempo empleando circuitos alargadores de resistencia-capacidad en relacion con su aplicacion para determinar si el producto de las amplitudes de dos impulsos coincidentes tiene un valor determinado. Indica algunos circuitos posibles. (author) [Russian] Obsuzhdayutsya predel pogreshnosti i ogranicheniya umnozhitelej, osnovannykh na logarifmicheskom preobrazovanii amplitudy vo vremya, s ispol'zovaniem rasshiritelej impul'sov RC; ehto delaetsya v svyazi s ikh primeneniem dlya vyyasneniya voprosa o tom, imeet li opredelennuyu velichinu proizvedenie amplitud dvukh sovpadayushchikh impul'sov. Privodyatsya nekotorye vozmozhnye blok-skhemy. (author)

  9. Differential pulse amplitude modulation for multiple-input single-output OWVLC

    Science.gov (United States)

    Yang, S. H.; Kwon, D. H.; Kim, S. J.; Son, Y. H.; Han, S. K.

    2015-01-01

    White light-emitting diodes (LEDs) are widely used for lighting due to their energy efficiency, eco-friendly, and small size than previously light sources such as incandescent, fluorescent bulbs and so on. Optical wireless visible light communication (OWVLC) based on LED merges lighting and communications in applications such as indoor lighting, traffic signals, vehicles, and underwater communications because LED can be easily modulated. However, physical bandwidth of LED is limited about several MHz by slow time constant of the phosphor and characteristics of device. Therefore, using the simplest modulation format which is non-return-zero on-off-keying (NRZ-OOK), the data rate reaches only to dozens Mbit/s. Thus, to improve the transmission capacity, optical filtering and pre-, post-equalizer are adapted. Also, high-speed wireless connectivity is implemented using spectrally efficient modulation methods: orthogonal frequency division multiplexing (OFDM) or discrete multi-tone (DMT). However, these modulation methods need additional digital signal processing such as FFT and IFFT, thus complexity of transmitter and receiver is increasing. To reduce the complexity of transmitter and receiver, we proposed a novel modulation scheme which is named differential pulse amplitude modulation. The proposed modulation scheme transmits different NRZ-OOK signals with same amplitude and unit time delay using each LED chip, respectively. The `N' parallel signals from LEDs are overlapped and directly detected at optical receiver. Received signal is demodulated by power difference between unit time slots. The proposed scheme can overcome the bandwidth limitation of LEDs and data rate can be improved according to number of LEDs without complex digital signal processing.

  10. Resolving the contribution of the uncoupled phycobilisomes to cyanobacterial pulse-amplitude modulated (PAM) fluorometry signals.

    Science.gov (United States)

    Acuña, Alonso M; Snellenburg, Joris J; Gwizdala, Michal; Kirilovsky, Diana; van Grondelle, Rienk; van Stokkum, Ivo H M

    2016-01-01

    Pulse-amplitude modulated (PAM) fluorometry is extensively used to characterize photosynthetic organisms on the slow time-scale (1-1000 s). The saturation pulse method allows determination of the quantum yields of maximal (F(M)) and minimal fluorescence (F(0)), parameters related to the activity of the photosynthetic apparatus. Also, when the sample undergoes a certain light treatment during the measurement, the fluorescence quantum yields of the unquenched and the quenched states can be determined. In the case of cyanobacteria, however, the recorded fluorescence does not exclusively stem from the chlorophyll a in photosystem II (PSII). The phycobilins, the pigments of the cyanobacterial light-harvesting complexes, the phycobilisomes (PB), also contribute to the PAM signal, and therefore, F(0) and F(M) are no longer related to PSII only. We present a functional model that takes into account the presence of several fluorescent species whose concentrations can be resolved provided their fluorescence quantum yields are known. Data analysis of PAM measurements on in vivo cells of our model organism Synechocystis PCC6803 is discussed. Three different components are found necessary to fit the data: uncoupled PB (PB(free)), PB-PSII complexes, and free PSI. The free PSII contribution was negligible. The PB(free) contribution substantially increased in the mutants that lack the core terminal emitter subunits allophycocyanin D or allophycocyanin F. A positive correlation was found between the amount of PB(free) and the rate constants describing the binding of the activated orange carotenoid protein to PB, responsible for non-photochemical quenching.

  11. An evaluation of the effects of eyeball structure on ocular pulse amplitude in healthy subjects.

    Science.gov (United States)

    Ishii, Kotaro; Mori, Mikiro; Oshika, Tetsuro

    2012-12-01

    To evaluate the effects of eyeball structure on ocular pulse amplitude (OPA) measured using dynamic contour tonometer (DCT). In 86 eyes of 43 healthy subjects, we measured OPA and intraocular pressure (IOP) with DCT (DCT-IOP), IOP with Goldmann applanation tonometry (GAT-IOP), central corneal thickness (CCT), corneal thickness 2 mm (2 mmCT) and 4 mm (4 mmCT) apart from the center, corneal volume within a 3.5-mm radius from the corneal center, corneal curvature, anterior chamber depth, anterior chamber volume, and axial length (AL). OPA had a significant positive correlation with GAT-IOP (Pearson's r = 0.412, p < 0.001), DCT-IOP (r = 0.350, p < 0.001), and 4 mmCT (r = 0.244, p = 0.0231), and had a significant negative correlation with AL (r = -0.268, p = 0.0122). In a multiple linear regression analysis, AL and GAT-IOP were significantly associated with OPA. OPA measured with DCT is significantly influenced by several factors, such as IOP, peripheral corneal thickness (4 mmCT), and AL.

  12. Optical spectral reshaping for directly modulated 4-pulse amplitude modulation signals

    DEFF Research Database (Denmark)

    Ozolins, Oskars; Da Ros, Francesco; Cristofori, Valentina

    2017-01-01

    The tremendous traffic growth in intra/inter-datacenters requires low-cost high-speed integrated solutions [1]. To enable a significantly reduced footprint directly modulated lasers (DMLs) have been proposed instead of large external modulators. However, it is challenging to use DMLs due to their......The tremendous traffic growth in intra/inter-datacenters requires low-cost high-speed integrated solutions [1]. To enable a significantly reduced footprint directly modulated lasers (DMLs) have been proposed instead of large external modulators. However, it is challenging to use DMLs due...... (PAM) [3] signals. However, moving to 4-PAM,many of the impressive demonstrations reported so far rely heavily on off-line digital signal processing (DSP), which increases latency, power consumption and cost. In this talk, we report on (i) a detailed numerical analysis on the complex transfer function...... of the optical filter for optical spectral reshaping in case of pulse amplitude modulation and(ii) an experimental demonstration of real-time dispersion-uncompensated transmission of 10-GBd and 14-GBd 4-PAM signals up to 10- and 26-km SSMF. This is achieved by combining a commercial 10-Gb/s DML with optical...

  13. A high-resolution two-pulse coherent anti-Stokes Raman scattering spectrum using a spectral amplitude modulation

    International Nuclear Information System (INIS)

    Lu, Chenhui; Zhang, Shian; Wu, Meizhen; Jia, Tianqing; Sun, Zhenrong; Qiu, Jianrong

    2013-01-01

    Femtosecond coherent anti-Stokes Raman scattering (CARS) spectra suffer from low spectral resolution because of the broadband laser spectrum. In this paper, we propose a feasible scheme to achieve a high-resolution two-pulse CARS spectrum by shaping both the pump and probe pulses using rectangular amplitude modulation. We show that a narrowband hole in the CARS spectrum can be created by the amplitude-shaped laser pulse, the position of which is correlated with the Raman resonant frequency of the molecule. Thus, by observing holes in the CARS spectrum, we are able to obtain a high-resolution CARS spectrum and the energy-level diagram of the molecule. (paper)

  14. Practical use of the amplitude and phase modulation of a high-power RF pulse via feed-forward control

    International Nuclear Information System (INIS)

    Kawase, Keigo; Kato, Ryukou; Irizawa, Akinori; Isoyama, Goro; Kashiwagi, Shigeru

    2013-01-01

    A new feed-forward control system to precisely control the amplitude and phase of the pulsed RF power in an electron linear accelerator (linac) is developed to make the accelerating field constant. Fast variations and ripples in the amplitude and phase in the RF pulses are compensated by modulating the amplitude and phase in the low-level system with a variable attenuator and phase shifter. The system is innovated the overdrive technique, which is commonly used in analog circuits, to speed up the slow response of the phase shifter, while the control signals are digitally processed; thus, the method is a hybrid of analog and digital techniques. By using the new control system, we find that the peak-to-peak variations in the amplitude and phase are reduced from 11.6% to 0.4% and from 6.1 degrees to 0.3 degrees, respectively, in 7.6-μs-long RF pulses for the L-band electron linac at Osaka University. (author)

  15. Sensitivity evaluation of the green alga Chlamydomonas reinhardtii to uranium by pulse amplitude modulated (PAM) fluorometry.

    Science.gov (United States)

    Herlory, Olivier; Bonzom, Jean-Marc; Gilbin, Rodolphe

    2013-09-15

    Although ecotoxicological studies tend to address the toxicity thresholds of uranium in freshwaters, there is a lack of information on the effects of the metal on physiological processes, particularly in aquatic plants. Knowing that uranium alters photosynthesis via impairment of the water photo-oxidation process, we determined whether pulse amplitude modulated (PAM) fluorometry was a relevant tool for assessing the impact of uranium on the green alga Chlamydomonas reinhardtii and investigated how and to what extent uranium hampered photosynthetic performance. Photosynthetic activity and quenching were assessed from fluorescence induction curves generated by PAM fluorometry, after 1 and 5h of uranium exposure in controlled conditions. The oxygen-evolving complex (OEC) of PSII was identified as the primary action site of uranium, through alteration of the water photo-oxidation process as revealed by F0/Fv. Limiting re-oxidation of the plastoquinone pool, uranium impaired the electron flux between the photosystems until almost complete inhibition of the PSII quantum efficiency ( [Formula: see text] , EC50=303 ± 64 μg UL(-1) after 5h of exposure) was observed. Non-photochemical quenching (qN) was identified as the most sensitive fluorescence parameter (EC50=142 ± 98 μg UL(-1) after 5h of exposure), indicating that light energy not used in photochemistry was dissipated in non-radiative processes. It was shown that parameters which stemmed from fluorescence induction kinetics are valuable indicators for evaluating the impact of uranium on PSII in green algae. PAM fluorometry provided a rapid and reasonably sensitive method for assessing stress response to uranium in microalgae. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry.

    Science.gov (United States)

    Hoffmann, Esther M; Grus, Franz-H; Pfeiffer, Norbert

    2004-03-23

    The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted DCT were compared to the IOP and OPA measured with the hand-held SmartLens,a gonioscopic contact lens tonometer (ODC Ophthalmic Development Company AG, Switzerland). Nineteen healthy subjects were included in this study. IOP was determined by three consecutive measurements with each of the DCT, SmartLens, and Goldmann tonometer. Furthermore, OPA was measured three times consecutively by DCT and SmartLens. No difference (P = 0.09) was found between the IOP values by means of DCT (mean: 16.6 mm Hg, median: 15.33 mm Hg, SD: +/- 4.04 mm Hg) and Goldmann tonometry (mean: 16.17 mm Hg, median: 15.33 mm Hg, SD: +/- 4.03 mm Hg). The IOP values of SmartLens (mean: 20.25 mm Hg, median: 19.00 mm Hg, SD: +/- 4.96 mm Hg) were significantly higher (P = 0.0008) both from Goldmann tonometry and DCT. The OPA values of the DCT (mean: 3.08 mm Hg, SD: +/- 0.92 mm Hg) were significantly lower (P = 0.0003) than those obtained by SmartLens (mean: 3.92 mm Hg, SD: +/- 0.83 mm Hg). DCT was equivalent to Goldmann applanation tonometry in measurement of IOP in a small group of normal subjects. In contrast, SmartLens (contact lens tonometry) gave IOP readings that were significantly higher compared with Goldmann applanation tonometer readings. Both devices, DCT and SmartLens provide the measurement of OPA which could be helpful e.g. for the management of glaucoma.

  17. Test-retest reliability of pulse amplitude tonometry measures of vascular endothelial function: implications for clinical trial design.

    Science.gov (United States)

    McCrea, Cindy E; Skulas-Ray, Ann C; Chow, Mosuk; West, Sheila G

    2012-02-01

    Endothelial dysfunction is an important outcome for assessing vascular health in intervention studies. However, reliability of the standard non-invasive method (flow-mediated dilation) is a significant challenge for clinical applications and multicenter trials. We evaluated the repeatability of pulse amplitude tonometry (PAT) to measure change in pulse wave amplitude during reactive hyperemia (Itamar Medical Ltd, Caesarea, Israel). Twenty healthy adults completed two PAT tests (mean interval = 19.5 days) under standardized conditions. PAT-derived measures of endothelial function (reactive hyperemia index, RHI) and arterial stiffness (augmentation index, AI) showed strong repeatability (intra-class correlations = 0.74 and 0.83, respectively). To guide future research, we also analyzed sample size requirements for a range of effect sizes. A crossover design powered at 0.90 requires 28 participants to detect a 15% change in RHI. Our study is the first to show that PAT measurements are repeatable in adults over an interval greater than 1 week.

  18. Sensitivity evaluation of the green alga Chlamydomonas reinhardtii to uranium by pulse amplitude modulated (PAM) fluorometry

    International Nuclear Information System (INIS)

    Herlory, Olivier; Bonzom, Jean-Marc; Gilbin, Rodolphe

    2013-01-01

    Highlights: •Our study addressed the toxicity thresholds of uranium on microalgae using PAM fluorometry. •The oxygen-evolving complex (OEC) of PSII was identified as the primary action site of uranium. •Uranium impaired the electron flux between the photosystems until almost complete inhibition. •Non-photochemical quenching was identified as the most sensitive fluorescence parameter. •PAM fluorometry provided a rapid and reasonably sensitive method for assessing stress response. -- Abstract: Although ecotoxicological studies tend to address the toxicity thresholds of uranium in freshwaters, there is a lack of information on the effects of the metal on physiological processes, particularly in aquatic plants. Knowing that uranium alters photosynthesis via impairment of the water photo-oxidation process, we determined whether pulse amplitude modulated (PAM) fluorometry was a relevant tool for assessing the impact of uranium on the green alga Chlamydomonas reinhardtii and investigated how and to what extent uranium hampered photosynthetic performance. Photosynthetic activity and quenching were assessed from fluorescence induction curves generated by PAM fluorometry, after 1 and 5 h of uranium exposure in controlled conditions. The oxygen-evolving complex (OEC) of PSII was identified as the primary action site of uranium, through alteration of the water photo-oxidation process as revealed by F 0 /F v . Limiting re-oxidation of the plastoquinone pool, uranium impaired the electron flux between the photosystems until almost complete inhibition of the PSII quantum efficiency (F ′ q /F ′ m , EC 50 = 303 ± 64 μg U L −1 after 5 h of exposure) was observed. Non-photochemical quenching (qN) was identified as the most sensitive fluorescence parameter (EC 50 = 142 ± 98 μg U L −1 after 5 h of exposure), indicating that light energy not used in photochemistry was dissipated in non-radiative processes. It was shown that parameters which stemmed from

  19. Sensitivity evaluation of the green alga Chlamydomonas reinhardtii to uranium by pulse amplitude modulated (PAM) fluorometry

    Energy Technology Data Exchange (ETDEWEB)

    Herlory, Olivier, E-mail: olivier.herlory@gmail.com [IRSN-Laboratoire d’Ecotoxicologie des Radionucléides, Centre de Cadarache, BP3, 13115 Saint Paul lez Durance (France); Bonzom, Jean-Marc, E-mail: jean-marc.bonzom@irsn.fr [IRSN-Laboratoire d’Ecotoxicologie des Radionucléides, Centre de Cadarache, BP3, 13115 Saint Paul lez Durance (France); Gilbin, Rodolphe, E-mail: rodolphe.gilbin@irsn.fr [IRSN-Laboratoire de Biogéochimie, Biodisponibilité et Transferts des Radionucléides, Centre de Cadarache, BP3, 13115 Saint Paul lez Durance (France)

    2013-09-15

    Highlights: •Our study addressed the toxicity thresholds of uranium on microalgae using PAM fluorometry. •The oxygen-evolving complex (OEC) of PSII was identified as the primary action site of uranium. •Uranium impaired the electron flux between the photosystems until almost complete inhibition. •Non-photochemical quenching was identified as the most sensitive fluorescence parameter. •PAM fluorometry provided a rapid and reasonably sensitive method for assessing stress response. -- Abstract: Although ecotoxicological studies tend to address the toxicity thresholds of uranium in freshwaters, there is a lack of information on the effects of the metal on physiological processes, particularly in aquatic plants. Knowing that uranium alters photosynthesis via impairment of the water photo-oxidation process, we determined whether pulse amplitude modulated (PAM) fluorometry was a relevant tool for assessing the impact of uranium on the green alga Chlamydomonas reinhardtii and investigated how and to what extent uranium hampered photosynthetic performance. Photosynthetic activity and quenching were assessed from fluorescence induction curves generated by PAM fluorometry, after 1 and 5 h of uranium exposure in controlled conditions. The oxygen-evolving complex (OEC) of PSII was identified as the primary action site of uranium, through alteration of the water photo-oxidation process as revealed by F{sub 0}/F{sub v}. Limiting re-oxidation of the plastoquinone pool, uranium impaired the electron flux between the photosystems until almost complete inhibition of the PSII quantum efficiency (F{sup ′}{sub q}/F{sup ′}{sub m}, EC{sub 50} = 303 ± 64 μg U L{sup −1} after 5 h of exposure) was observed. Non-photochemical quenching (qN) was identified as the most sensitive fluorescence parameter (EC{sub 50} = 142 ± 98 μg U L{sup −1} after 5 h of exposure), indicating that light energy not used in photochemistry was dissipated in non-radiative processes. It was shown

  20. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

    Directory of Open Access Journals (Sweden)

    Grus Franz-H

    2004-03-01

    Full Text Available Abstract Background The new Ocular Dynamic Contour Tonometer (DCT, investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland allows simultaneous recording of intraocular pressure (IOP and ocular pulse amplitude (OPA. It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted DCT were compared to the IOP and OPA measured with the hand-held SmartLens®, a gonioscopic contact lens tonometer (ODC Ophthalmic Development Company AG, Switzerland. Methods Nineteen healthy subjects were included in this study. IOP was determined by three consecutive measurements with each of the DCT, SmartLens®, and Goldmann tonometer. Furthermore, OPA was measured three times consecutively by DCT and SmartLens®. Results No difference (P = 0.09 was found between the IOP values by means of DCT (mean: 16.6 mm Hg, median: 15.33 mm Hg, SD: +/- 4.04 mm Hg and Goldmann tonometry (mean: 16.17 mm Hg, median: 15.33 mm Hg, SD: +/- 4.03 mm Hg. The IOP values of SmartLens® (mean: 20.25 mm Hg, median: 19.00 mm Hg, SD: +/- 4.96 mm Hg were significantly higher (P = 0.0008 both from Goldmann tonometry and DCT. The OPA values of the DCT (mean: 3.08 mm Hg, SD: +/- 0.92 mm Hg were significantly lower (P = 0.0003 than those obtained by SmartLens® (mean: 3.92 mm Hg, SD: +/- 0.83 mm Hg. Conclusions DCT was equivalent to Goldmann applanation tonometry in measurement of IOP in a small group of normal subjects. In contrast, SmartLens® (contact lens tonometry gave IOP readings that were significantly higher compared with Goldmann applanation tonometer readings. Both devices, DCT and SmartLens® provide the measurement of OPA which could be helpful e.g. for the management of glaucoma.

  1. Emission of ultrashort electromagnetic pulses from electron bunches formed and accelerated by laser beams with tilted amplitude fronts

    International Nuclear Information System (INIS)

    Galkin, A.L.; Korobkin, V.V.; Romanovsky, M.Yu.; Shiryaev, O.B.; Trofimov, V.A.

    2013-01-01

    The dynamics of an electron in a standing wave generated by a pair of counterpropagating linearly polarized relativistically intense laser pulses and the emission of electromagnetic radiation by the electron are analyzed. The pulses are assumed to have tilted amplitude fronts and asymmetric focal spots. The analysis of the dynamics is performed by solving numerically the Newton equation with the corresponding Lorentz force, and the emission of radiation is simulated based on the Lienard-Wiechert potentials. The electrons are accelerated by the direct action of the standing wave field and are shown to form a small short bunch. For relativistic intensities, the energies gained by the electrons reach several GeV. It is demonstrated that the radiation emitted by the electrons in the bunch is a single electromagnetic pulse confined to a narrow solid angle and having an attosecond duration. (copyright 2013 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. High amplitude ultrasound pulse generation using time-reversal through a multiple scattering medium

    OpenAIRE

    ARNAL , Bastien; Pernot , Mathieu; Fink , Mathias; Tanter , Mickaël

    2012-01-01

    International audience; In histotripsy, soft tissues can be fragmented using very high pressure ultrasound pulses. Using time-reversal cavity is a way to generate high pressure pulses with a limited number of acoustic sources. The principle was already demonstrated by Montaldo et al. using a solid metal cavity, but low transmission coefficient was obtained due to the strong impedance mismatch at the metal/water interface. We propose here to use a waveguide filled with water containing a 2D mu...

  3. Generation of longitudinally polarized terahertz pulses with field amplitudes exceeding 2 kV/cm

    Energy Technology Data Exchange (ETDEWEB)

    Cliffe, M. J., E-mail: Matthew.Cliffe@manchester.ac.uk; Rodak, A.; Graham, D. M. [School of Physics and Astronomy and the Photon Science Institute, The University of Manchester, Manchester M13 9PL (United Kingdom); The Cockcroft Institute, Sci-Tech Daresbury, Keckwick Lane, Daresbury, Warrington WA4 4AD (United Kingdom); Jamison, S. P. [The Cockcroft Institute, Sci-Tech Daresbury, Keckwick Lane, Daresbury, Warrington WA4 4AD (United Kingdom); Accelerator Science and Technology Centre, Science and Technology Facilities Council, Darebsury Laboratory, Keckwick Lane, Daresbury, Warrington WA4 4AD (United Kingdom)

    2014-11-10

    We demonstrate the generation of near-single cycle longitudinally polarized terahertz radiation using a large-area radially biased photoconductive antenna with a longitudinal field amplitude in excess of 2 kV/cm. The 76 mm diameter antenna was photo-excited by a 0.5 mJ amplified near-infrared femtosecond laser system and biased with a voltage of up to 100 kV applied over concentric electrodes. Amplitudes for both the transverse and longitudinal field components of the source were measured using a calibrated electro-optic detection scheme. By tightly focusing the radiation emitted from the photoconductive antenna, we obtained a maximum longitudinal field amplitude of 2.22 kV/cm with an applied bias field of 38.5 kV/cm.

  4. Generation of longitudinally polarized terahertz pulses with field amplitudes exceeding 2 kV/cm

    Science.gov (United States)

    Cliffe, M. J.; Rodak, A.; Graham, D. M.; Jamison, S. P.

    2014-11-01

    We demonstrate the generation of near-single cycle longitudinally polarized terahertz radiation using a large-area radially biased photoconductive antenna with a longitudinal field amplitude in excess of 2 kV/cm. The 76 mm diameter antenna was photo-excited by a 0.5 mJ amplified near-infrared femtosecond laser system and biased with a voltage of up to 100 kV applied over concentric electrodes. Amplitudes for both the transverse and longitudinal field components of the source were measured using a calibrated electro-optic detection scheme. By tightly focusing the radiation emitted from the photoconductive antenna, we obtained a maximum longitudinal field amplitude of 2.22 kV/cm with an applied bias field of 38.5 kV/cm.

  5. Generation of longitudinally polarized terahertz pulses with field amplitudes exceeding 2 kV/cm

    International Nuclear Information System (INIS)

    Cliffe, M. J.; Rodak, A.; Graham, D. M.; Jamison, S. P.

    2014-01-01

    We demonstrate the generation of near-single cycle longitudinally polarized terahertz radiation using a large-area radially biased photoconductive antenna with a longitudinal field amplitude in excess of 2 kV/cm. The 76 mm diameter antenna was photo-excited by a 0.5 mJ amplified near-infrared femtosecond laser system and biased with a voltage of up to 100 kV applied over concentric electrodes. Amplitudes for both the transverse and longitudinal field components of the source were measured using a calibrated electro-optic detection scheme. By tightly focusing the radiation emitted from the photoconductive antenna, we obtained a maximum longitudinal field amplitude of 2.22 kV/cm with an applied bias field of 38.5 kV/cm

  6. Ventricular repolarization time, location of pacing stimulus and current pulse amplitude conspire to determine arrhythmogenicity in mice

    DEFF Research Database (Denmark)

    Speerschneider, T; Grubb, Søren Jahn; Olesen, S P

    2017-01-01

    ) were measured in isolated hearts using floating microelectrodes. RESULTS: Proarrhythmia in WT and KChIP2(-/-) was not sensitive to changes in refractory periods. Action potentials were longer in KChIP2(-/-) hearts compared to WT hearts. Isolated WT hearts had large apico-basal dispersion...... of repolarization time, whereas hearts from KChIP2(-/-) mice had large left-to-right ventricular dispersion of repolarization time. Pacing from the right ventricle in KChIP2(-/-) mice in vivo revealed significant lower current pulse amplitudes needed to induce arrhythmias in these mice. CONCLUSION: Large...

  7. A 900-channel coincidence pulse-amplitude analyser; Selecteur d'amplitudes d'impulsions a coincidence a trois dimensions; Devyatisotkanal'nyj amplitudnyj analizator impul'sov sovpadeniya; Analizador de amplitud de impulsos de coincidencia con 900 canales

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T K; Robinson, L B [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1962-04-15

    An analyser designed for correlation studies of pulse-height distributions from two scintillation counters is described. The analyser consists of two separate transistorized units; a dual-channel analogue-to-digital encoder and a 900-channel, 2{sup 16}-per-channel capacity ferrite-core store. The display and control unit for the instrument is separate and can be situated away from the analyser. The analysis mode of operation for coincident pulses on the A and B inputs of the encoder can be selected to be 30 by 30, 100 by 9 or 300 channels by 3 distributions. In the last two modes the base lines and the widths of the pulse-amplitude ''windows'' on distribution A can be selected by the operator. With 100 channels for pulse-amplitude analysis, eight ''windows'' in distribution A define eight groups of 100 channels for the B distributions. In this case we have, in effect, one 100-channel analyser for distribution A and eight separate 100-channel analysers to which B can be routed. A description of the basic circuits of the encoder and the logic of the store and display units is given. (author) [French] Le memoire decrit un selecteur concu pour etudier la correlation des distributions en amplitude des impulsions fournies par deux compteurs a scintillations. L'analyseur se compose de deux parties distinctes transistorisees: un codeur analogique/numerique a deux voies et une memoire a ferrites, a 900 canaux d'une capacite de 2{sup 16} par canal. Les tableaux d'enregistrement et les commandes de l'appareil forment un element autonome qui peut etre installe a une certaine distance du selecteur. Pour l'analyse des impulsions de coincidence aux entrees A et B du codeur, on peut combiner les canaux de trois manieres differentes: 30 x 30, 100 x 9 ou 300 x 3. Dans les deux derniers cas, l'operateur peut choisir les lignes de base et la largeur des des amplitudes d'impulsion pour la distribution A. Lorsque l'analyse de l'amplitude d'impulsion se fait avec 100 canaux

  8. Measurement of pulse amplitude and phase using cross-phase modulation in microstructure fiber

    Czech Academy of Sciences Publication Activity Database

    Honzátko, Pavel; Kaňka, Jiří; Vraný, Boleslav

    2005-01-01

    Roč. 30, č. 14 (2005), s. 1821-1823 ISSN 0146-9592 R&D Projects: GA ČR(CZ) GA102/05/0995; GA AV ČR(CZ) IAA1067301 Institutional research plan: CEZ:AV0Z20670512 Keywords : pulse measurement * phase measurement * nonlinear optics Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.599, year: 2005

  9. Method of summation of amplitudes of coinciding pulses from Ge(Li) detectors used to study cascades of gamma-transitions in (n,#betta#) reaction

    International Nuclear Information System (INIS)

    Bogdzel', A.A.; Vasil'eva, Eh.V.; Elizarov, O.I.

    1982-01-01

    Main performanes and peculiarities of spectrometer based on the coincidence pulse amplitude total-count method and containing two Ge(La) detectors with transmission neutron spectrometer - IBR-30 pulse reactor are considered. It is shown on the 35 Cl(n, #betta#) reaction that the method of summalion of amplitudes of coinciding pulses from the Ge(Li) detector can be used to study the cascades of two #betta#-transitions with a total energy similar to the neutron binding energy. The shape of the response function of this spectrometer was studied versus the energies of #betta#-transition cascades

  10. Bystander Effect Induced by Electroporation is Possibly Mediated by Microvesicles and Dependent on Pulse Amplitude, Repetition Frequency and Cell Type.

    Science.gov (United States)

    Prevc, Ajda; Bedina Zavec, Apolonija; Cemazar, Maja; Kloboves-Prevodnik, Veronika; Stimac, Monika; Todorovic, Vesna; Strojan, Primoz; Sersa, Gregor

    2016-10-01

    Bystander effect, a known phenomenon in radiation biology, where irradiated cells release signals which cause damage to nearby, unirradiated cells, has not been explored in electroporated cells yet. Therefore, our aim was to determine whether bystander effect is present in electroporated melanoma cells in vitro, by determining viability of non-electroporated cells exposed to medium from electroporated cells and by the release of microvesicles as potential indicators of the bystander effect. Here, we demonstrated that electroporation of cells induces bystander effect: Cells exposed to electric pulses mediated their damage to the non-electroporated cells, thus decreasing cell viability. We have shown that shedding microvesicles may be one of the ways used by the cells to mediate the death signals to the neighboring cells. The murine melanoma B16F1 cell line was found to be more electrosensitive and thus more prone to bystander effect than the canine melanoma CMeC-1 cell line. In B16F1 cell line, bystander effect was present above the level of electropermeabilization of the cells, with the threshold at 800 V/cm. Furthermore, with increasing electric field intensities and the number of pulses, the bystander effect also increased. In conclusion, electroporation can induce bystander effect which may be mediated by microvesicles, and depends on pulse amplitude, repetition frequency and cell type.

  11. Vaginal Infections

    Science.gov (United States)

    ... gov/ Home Body Your reproductive health Vaginal infections Vaginal infections Help for infections If you have pain, ... infections and how to prevent them. Types of vaginal infections top Two common vaginal infections are bacterial ...

  12. Vaginal Atrophy

    Science.gov (United States)

    ... an Endocrinologist Search Featured Resource Menopause Map™ View Vaginal Atrophy October 2017 Download PDFs English Editors Christine ... during this time, including vaginal dryness. What is vaginal atrophy? Vaginal atrophy (also referred to as vulvovaginal ...

  13. Vaginal Atrophy

    Science.gov (United States)

    ... urinary signs and symptoms: Vaginal dryness Vaginal burning Vaginal discharge Genital itching Burning with urination Urgency with urination ... others). Also make an appointment if you have vaginal symptoms, such as unusual ... burning or soreness. Causes Genitourinary syndrome of menopause ( ...

  14. Using a heterodyne vibrometer in combination with pulse excitation for primary calibration of ultrasonic hydrophones in amplitude and phase

    Science.gov (United States)

    Weber, Martin; Wilkens, Volker

    2017-08-01

    A high-frequency vibrometer was used with ultrasonic pulse excitation in order to perform a primary hydrophone calibration. This approach enables the simultaneous characterization of the amplitude and phase transfer characteristic of ultrasonic hydrophones. The method allows a high frequency resolution in a considerably short time for the measurement. Furthermore, the uncertainty contributions of this approach were investigated and quantified. A membrane hydrophone was calibrated and the uncertainty budget for this measurement was determined. The calibration results are presented up to 70~\\text{MHz} . The measurement results show good agreement with the results obtained by sinusoidal burst excitation through the use of the vibrometer and by a homodyne laser interferometer, with RMS deviation of approximately 3% -4% in the frequency range from 1 to 60~\\text{MHz} . Further hydrophones were characterized up to 100~\\text{MHz} with this procedure to demonstrate the suitability for very high frequency calibration.

  15. Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

    Energy Technology Data Exchange (ETDEWEB)

    Krastelev, E. G., E-mail: ekrastelev@yandex.ru; Sedin, A. A.; Tugushev, V. I. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-12-15

    A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz.

  16. Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

    International Nuclear Information System (INIS)

    Krastelev, E. G.; Sedin, A. A.; Tugushev, V. I.

    2015-01-01

    A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz

  17. INTERACTION OF RADIATION WITH MATTER. LASER PLASMA: Increase in the amplitude of hf currents during exposure of a neutral target to microsecond CO2 laser pulses

    Science.gov (United States)

    Antipov, A. A.; Losev, Leonid L.; Meshalkin, E. A.

    1988-09-01

    High-frequency electric currents were generated by irradiation of a metal target with CO2 laser pulses. It was found that the region where the ambient gas was photoionized had a decisive influence on the hf current amplitude. A method for increasing the amplitude of the current by creating an auxiliary laser jet on the target was proposed and used. An hf current of up to 1 A amplitude was observed at a frequency of 75 MHz and this current lasted for 1.5 μs.

  18. Vaginal Odor

    Science.gov (United States)

    ... normally occurring vaginal bacteria — is the most common vaginal infection that causes a vaginal odor. Trichomoniasis — a sexually transmitted infection — also can lead to vaginal odor. Chlamydia and gonorrhea infections usually don't cause vaginal odors. Neither do ...

  19. Extremum seeking to control the amplitude and frequency of a pulsed jet for bluff body drag reduction

    Science.gov (United States)

    Brackston, Rowan D.; Wynn, Andrew; Morrison, Jonathan F.

    2016-10-01

    Feedback control of fluid flows presents a challenging problem due to nonlinear dynamics and unknown optimal operating conditions. Extremum seeking control presents a suitable method for many flow control situations but involves its own challenges. In this paper, we provide a brief analysis of the extremum seeking method, with attention to modifications that we find to be advantageous. In particular, we present an adaptation for optimisation of the frequency of a harmonic input signal, a common scenario for open-loop flow control systems. We then present results from the experimental implementation of our modified method to the open-loop control system of Oxlade et al. (J Fluid Mech 770:305-318, 2015), an axisymmetric bluff-body wake, forced by a pulsed jet. We find that the system is able to achieve optimal operating conditions in both the amplitude and frequency of the harmonic input signal, and is able to largely reject the disturbances arising from measurements of a highly turbulent flow. We finally show the ability of the extremum seeking system to adapt to changing conditions.

  20. Problems in nonlinear acoustics: Scattering of sound by sound, parametric receiving arrays, nonlinear effects in asymmetric sound beams and pulsed finite amplitude sound beams

    Science.gov (United States)

    Hamilton, Mark F.

    1989-08-01

    Four projects are discussed in this annual summary report, all of which involve basic research in nonlinear acoustics: Scattering of Sound by Sound, a theoretical study of two nonconlinear Gaussian beams which interact to produce sum and difference frequency sound; Parametric Receiving Arrays, a theoretical study of parametric reception in a reverberant environment; Nonlinear Effects in Asymmetric Sound Beams, a numerical study of two dimensional finite amplitude sound fields; and Pulsed Finite Amplitude Sound Beams, a numerical time domain solution of the KZK equation.

  1. Vaginal disorders.

    Science.gov (United States)

    Soderberg, S F

    1986-05-01

    Chronic vaginitis is the most common vaginal disorder. Dogs with vaginitis show no signs of systemic illness but often lick at the vulva and have purulent or hemorrhagic vaginal discharges. Vaginitis is most commonly secondary to a noninfectious inciting factor such as congenital vaginal anomalies, clitoral hypertrophy, foreign bodies, trauma to the vaginal mucosa, or vaginal tumors. Inspection of the caudal vagina and vestibule both visually and digitally will often reveal the source of vaginal irritation. Vaginal cytology is used to establish the stage of the estrous cycle as well as distinguish uterine from vaginal sources of discharge. Vaginal cultures are used to establish the predominant offending organism associated with vaginal discharges and may be used as a guide for selection of a therapeutic agent. Vaginitis is best managed by removing the inciting cause and treating the area locally with antiseptic douches. Congenital malformations at the vestibulovaginal or vestibulovulvar junction may prevent normal intromission. Affected bitches may be reluctant to breed naturally because of pain. Such defects are detected best by digital examination. Congenital vaginal defects may be corrected by digital or surgical means. Prolapse of tissue through the lips of the vulva may be caused by clitoral hypertrophy, vaginal hyperplasia, or vaginal tumors. Enlargement of clitoral tissue is the result of endogenous or exogenous sources of androgens. Treatment of this condition includes removal of the androgen source and/or surgical removal of clitoral tissue. Vaginal hyperplasia is detected during proestrus or estrus of young bitches. Hyperplastic tissue will regress during diestrus. Tissue that is excessively traumatized and/or prolapse of the entire vaginal circumference may be removed surgically. Ovariohysterectomy may be used to prevent recurrence. Vaginal tumors are detected most often in older intact bitches. Such tumors are generally of smooth muscle or fibrous

  2. Vaginal cysts

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001509.htm Vaginal cysts To use the sharing features on this ... with air, fluid, pus, or other material. A vaginal cyst occurs on or under the lining of ...

  3. Vaginal Diseases

    Science.gov (United States)

    Vaginal problems are some of the most common reasons women go to the doctor. They may have ... common problem is vaginitis, an inflammation of the vagina. Other problems that affect the vagina include sexually ...

  4. Amplitude-measuring devices for electric pulses in the nanosecond region; Dispositifs de mesure d'amplitude d'impulsions electriques dans le domaine de la nanoseconde; Pribory dlya izmereniya amplitudy ehlektricheskikh impul'sov v sfere nanosekundy; Dispositivos para medir la amplitud de los impulsos electricos en la region del nanosegundo

    Energy Technology Data Exchange (ETDEWEB)

    Samueli, J J; Sarazin, A [Institut d' Etudes Nucleaires d' Alger (France)

    1962-04-15

    Two electronic circuits are described which permit measurement of the maximum amplitude of fast pulses. These circuits are usually required, if possible, to give independent indication of the duration and shape of the signal being studied. The first circuit is a pulse expander, i.e. an apparatus for converting fast signals into pulses of constant width and of amplitude proportional to the amplitude sought, thus permitting the study of fast signals with a conventional amplitude selector. The circuit can accept signals of width greater than two nanoseconds and of amplitude between 1 and 15 V. It delivers two signals of constant width 100 ns and 1 {mu}s. The second circuit is a fast amplitude-discriminator with an adjustable threshold from 1 to 30 V and a reading space of approximately 18% for pulses of 100 and 2 ns. The output signal has an amplitude of 1.5 V and a standard width of 0.2 {mu}s. (author) [French] Les auteurs decrivent deux circuits electroniques permettant d'effectuer des mesures d'amplitude maximum d'impulsions rapides. On demande en general a ces circuits de donner une indication independante, si possible, de la duree et de la forme du signal etudie. Le premier circuit est un allongeur d'impulsions, c'est-a-dire un appareil qui convertit des signaux rapides en impulsions de largeur constante et d'amplitude proportionnelle a l'amplitude cherchee et qui permet donc l'etude des signaux rapides par un selecteur d'amplitude conventionnel. Le circuit accepte des signaux de largeur superieure a 2 ns et d'amplitude comprise entre 1 et 15 V. Il delivre deux signaux de largeur constante, 100 ns et 1 {mu}s. Le second circuit est un discriminateur d'amplitude rapide, de seuil ajustable de 1 a 30 V et dont l'ecart de lecture pour des impulsions de largeur de 100 et 2 ns est de l'ordre de 18%. Le signal de sortie a une amplitude de 1,5 V et une largeur standard de 0,2 {mu}s. (author) [Spanish] Los autores describen dos circuitos electronicos que permiten medir la

  5. Interactions of Stress and Nicotine on Amplitude, Pre-Pulse Inhibition and Habituation of the Acoustic Startle Reflex

    Science.gov (United States)

    1992-09-24

    Marquez , Armario , & Gelpi, 1988) consistent with a stress response . Restraint stress has been reported to increase the amplitude of sensory...and NE in the brain (Adell , Garcia- Marquez , Armario , & Gelpi , 1988) consistent with a stress response. Restraint stress has been reported t o...and non- reactive strains. Al coholism. Clinical and Experimental Research, ~(2), 170-174. Adell, A., Garcia - Marquez, C., Armario , A. , & Gelpi , E

  6. Vaginal Cancer

    Science.gov (United States)

    Vaginal cancer is a rare type of cancer. It is more common in women 60 and older. You are also more likely to get it if you have had a human ... test can find abnormal cells that may be cancer. Vaginal cancer can often be cured in its ...

  7. Vaginal Fistula

    Science.gov (United States)

    Vaginal fistula Overview A vaginal fistula is an abnormal opening that connects your vagina to another organ, such as your bladder, colon or rectum. Your ... describe the condition as a hole in your vagina that allows stool or urine to pass through ...

  8. Phase and amplitude stability of a pulsed RF system on the example of the CLIC drive beam LINAC

    CERN Document Server

    AUTHOR|(CDS)2132320; Prof. BANTEL, Michael

    The CLIC drive beam accelerator consists of the Drive Beam Injector (DBI) and two Drive Beam Linacs (DBLs). The drive beam injector is composed of a thermionic electron source, 3 Sub Harmonic Bunchers (SHBs), a pre-buncher, and several acceleration structures. In the electron source the DC electron beam is produced from a thermionic cathode. The following buncher cavities group ("bunch") the electrons to be accelerated by RF later on. Each electron bunch has an energy of 140 keV, a length of 3 mm, and a charge qb = 8.4 nC. Afterwards the electrons are accelerated in the 1 GHz accelerating structures up to 50MeV. The pulsed Radio Frequency (RF) power for this acceleration is provided by 1 GHz, 20MW modulator-klystron units, one per acceleration structure. A klystron is an RF amplifier based on a linear-beam vacuum tube. The high voltage modulator supplies the acceleration voltage to this tube. A DC electron beam gets modulated with an input signal, the modulation enhances in a drift space, and finally the powe...

  9. Vaginal Bleeding

    Science.gov (United States)

    ... or period, is a woman's monthly bleeding.Abnormal vaginal bleeding is different from normal menstrual periods. It ... therapy) Cancer of the cervix, ovaries, uterus or vagina Thyroid problems Bleeding during pregnancy can have several ...

  10. Estrogen Vaginal

    Science.gov (United States)

    ... menopause (change of life; the end of monthly menstrual periods). Femring® brand estradiol vaginal ring is also ... applicator. Ask your pharmacist or doctor for a copy of the manufacturer's information for the patient.

  11. Vaginal cancer

    Science.gov (United States)

    Hacker NF. Vulvar and vaginal cancer. In: Hacker NF, Gambone JC, Hobel CJ, eds. Hacker and Moore's Essentials of Obstetrics and Gynecology . 6th ed. Philadelphia, PA: Elsevier; 2016:chap 40. Jhingran ...

  12. Vaginal reconstruction

    International Nuclear Information System (INIS)

    Lesavoy, M.A.

    1985-01-01

    Vaginal reconstruction can be an uncomplicated and straightforward procedure when attention to detail is maintained. The Abbe-McIndoe procedure of lining the neovaginal canal with split-thickness skin grafts has become standard. The use of the inflatable Heyer-Schulte vaginal stent provides comfort to the patient and ease to the surgeon in maintaining approximation of the skin graft. For large vaginal and perineal defects, myocutaneous flaps such as the gracilis island have been extremely useful for correction of radiation-damaged tissue of the perineum or for the reconstruction of large ablative defects. Minimal morbidity and scarring ensue because the donor site can be closed primarily. With all vaginal reconstruction, a compliant patient is a necessity. The patient must wear a vaginal obturator for a minimum of 3 to 6 months postoperatively and is encouraged to use intercourse as an excellent obturator. In general, vaginal reconstruction can be an extremely gratifying procedure for both the functional and emotional well-being of patients

  13. Vaginal Microbiota.

    Science.gov (United States)

    Mendling, Werner

    2016-01-01

    The knowledge about the normal and abnormal vaginal microbiome has changed over the last years. Culturing techniques are not suitable any more for determination of a normal or abnormal vaginal microbiota. Non culture-based modern technologies revealed a complex and dynamic system mainly dominated by lactobacilli.The normal and the abnormal vaginal microbiota are complex ecosystems of more than 200 bacterial species influenced by genes, ethnic background and environmental and behavioral factors. Several species of lactobacilli per individuum dominate the healthy vagina. They support a defense system together with antibacterial substances, cytokines, defensins and others against dysbiosis, infections and care for an normal pregnancy without preterm birth.The numbers of Lactobacillus (L.) iners increase in the case of dysbiosis.Bacterial vaginosis (BV) - associated bacteria (BVAB), Atopobium vaginae and Clostridiales and one or two of four Gardnerella vaginalis - strains develop in different mixtures and numbers polymicrobial biofilms on the vaginal epithelium, which are not dissolved by antibiotic therapies according to guidelines and, thus, provoke recurrences.Aerobic vaginitis seems to be an immunological disorder of the vagina with influence on the microbiota, which is here dominated by aerobic bacteria (Streptococcus agalactiae, Escherichia coli). Their role in AV is unknown.Vaginal or oral application of lactobacilli is obviously able to improve therapeutic results of BV and dysbiosis.

  14. Hysterectomy - vaginal - discharge

    Science.gov (United States)

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  15. Assisted Vaginal Delivery

    Science.gov (United States)

    ... Education & Events Advocacy For Patients About ACOG Assisted Vaginal Delivery Home For Patients Search FAQs Assisted Vaginal ... Vaginal Delivery FAQ192, February 2016 PDF Format Assisted Vaginal Delivery Labor, Delivery, and Postpartum Care What is ...

  16. Design of an electronic system with simultaneous registering of pulse amplitude and event time applied to the 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Toledo, Fabio de

    2009-01-01

    The 4πβ-γ coincidence method for absolute radionuclide activity measurement has been considered for many years as a primary standard in Nuclear Metrology, because of dependence on few observable quantities and high accuracy. The Laboratorio de Metrologia Nuclear (LMN) - Nuclear Metrology Laboratory -, at Instituto de Pesquisas Energeticas e Nucleares (IPEN) - Nuclear and Energy Research Institute -, among its measurement techniques, uses the 4πβ-γ coincidence method. Recently a new technique known as 'software coincidence' has been used, with many advantages over the conventional coincidence methodology. In order to update the methodologies for radionuclide standardizations, the LMN developed a new system based on the software coincidence technique, described in the present work. This system uses the same nuclear set up for beta and gamma detection. The new software coincidence electronics uses a National Instruments (NI) acquisition card connected to a microcomputer and, through a connection panel, to the nuclear detection set up. The card configuration and controlling is accomplished by software using the LabVIEW, a NI proprietary product. This system records into disk files all the amplitudes and occurrence times for beta and gamma detected pulses. A suitable software was developed (the coincidence analysis program) to process the recorded data in order to obtain beta, gamma and coincidence counts and perform calculation of the radioactive source activity. The work also presents and discusses the results obtained with the first version of the coincidence analysis program, as well as perspectives for future works. (author)

  17. Comparison of Ocular Pulse Amplitude Lowering Effects of Preservative-Free Tafluprost and Preservative-Free Dorzolamide-Timolol Fixed Combination Eyedrops.

    Science.gov (United States)

    Seo, Du Ri; Ha, Seung Joo

    2015-01-01

    To compare the ocular pulse amplitude (OPA) lowering effects of preservative-free tafluprost and dorzolamide-timolol fixed combination (DTFC) using dynamic contour tonometry. In total, 66 eyes of 66 patients with normal tension glaucoma (NTG) (n = 34) or primary open angle glaucoma (POAG) (n = 32) were included. Patients were divided into two groups: the preservative-free tafluprost-treated group (n = 33) and the preservative-free DTFC-treated group (n = 33). Intraocular pressure (IOP) was measured using Goldmann applanation tonometry (GAT). OPA was measured using dynamic contour tonometry; corrected OPA (cOPA) was calculated at baseline and at 1 week and 1, 3, and 6 months after treatment. After 6 months of treatment, tafluprost significantly reduced IOP (P < 0.001). The OPA lowering effects differed significantly between the two treatment groups (P = 0.003). The cOPA-lowering effect of tafluprost (1.09 mmHg) was significantly greater than that of DTFC (0.36 mmHg) after 6 months of treatment (P = 0.01). Tafluprost and DTFC glaucoma treatments provided marked OPA and IOP lowering effects. Tafluprost had a greater effect than DTFC; thus, this drug is recommended for patients at risk of glaucoma progression, due to the high OPA caused by large fluctuations in IOP.

  18. USE OF PULSE-AMPLITUDE-MODULATED FLUORESCENCE TO ASSESS THE PHYSIOLOGICAL STATUS OF CLADOPHORA SP. ALONG A WATER QUALITY GRADIENT(1).

    Science.gov (United States)

    Hiriart-Baer, Véronique P; Arciszewski, Tim J; Malkin, Sairah Y; Guildford, Stephanie J; Hecky, Robert E

    2008-12-01

    This study investigated the application of pulse-amplitude-modulated (PAM) fluorometry as a rapid assessment of benthic macroalgal physiological status. Maximum quantum efficiency (Fv /Fm ), dark-light induction curves, and rapid fluorescence light-response curves (RLC) were measured on the filamentous macroalgal Cladophora sp. from Lake Ontario on 5 d at 16 sites spanning a gradient of light and nutrient supply. For Cladophora sp. growing in situ, light limitation was assessed by comparing average daily irradiance with the light utilization efficiency parameter (α) derived from RLCs. In this study, there was a nonlinear relationship between Fv /Fm and the degree of P limitation in macroalgae. However, only light-saturated Cladophora sp. showed a significant positive linear relationship between Fv /Fm and P nutrient status. The absence of this relationship among light-limited algae indicates that their photosynthetic rate would be stimulated by increased water clarity, and not by increased P supply. PAM fluorescence measures were successfully able to identify light-saturated macroalgae and, among these, assess the degree to which they were nutrient limited. These results enable us to test hypotheses arising from numeric models predicting the impact of changes in light penetration and nutrient supply on benthic primary production. © 2008 Phycological Society of America.

  19. Negative response of photosynthesis to natural and projected high seawater temperatures estimated by pulse amplitude modulation fluorometry in a temperate coral.

    Science.gov (United States)

    Caroselli, Erik; Falini, Giuseppe; Goffredo, Stefano; Dubinsky, Zvy; Levy, Oren

    2015-01-01

    Balanophyllia europaea is a shallow water solitary zooxanthellate coral, endemic to the Mediterranean Sea. Extensive field studies across a latitudinal temperature gradient highlight detrimental effects of rising temperatures on its growth, demography, and skeletal characteristics, suggesting that depression of photosynthesis at high temperatures might cause these negative effects. Here we test this hypothesis by analyzing, by means of pulse amplitude modulation fluorometry, the photosynthetic efficiency of B. europaea specimens exposed in aquaria to the annual range of temperatures experienced in the field (13, 18, and 28°C), and two extreme temperatures expected for 2100 as a consequence of global warming (29 and 32°C). The indicators of photosynthetic performance analyzed (maximum and effective quantum yield) showed that maximum efficiency was reached at 20.0-21.6°C, slightly higher than the annual mean temperature in the field (18°C). Photosynthetic efficiency decreased from 20.0 to 13°C and even more strongly from 21.6 to 32°C. An unusual form of bleaching was observed, with a maximum zooxanthellae density at 18°C that strongly decreased from 18 to 32°C. Chlorophyll a concentration per zooxanthellae cell showed an opposite trend as it was minimal at 18°C and increased from 18 to 32°C. Since the areal chlorophyll concentration is the product of the zooxanthellae density and its cellular content, these trends resulted in a homogeneous chlorophyll concentration per coral surface across temperature treatments. This confirms that B. europaea photosynthesis is progressively depressed at temperatures >21.6°C, supporting previous hypotheses raised by the studies on growth and demography of this species. This study also confirms the threats posed to this species by the ongoing seawater warming.

  20. Negative response of photosynthesis to natural and projected high seawater temperatures estimated by pulse amplitude modulation fluorometry in a temperate coral

    Directory of Open Access Journals (Sweden)

    Erik eCaroselli

    2015-11-01

    Full Text Available Balanophyllia europaea is a shallow water solitary zooxanthellate coral, endemic to the Mediterranean Sea. Extensive field studies across a latitudinal temperature gradient highlight detrimental effects of rising temperatures on its growth, demography and skeletal characteristics, suggesting that depression of photosynthesis at high temperatures might cause these negative effects. Here we test this hypothesis by analyzing, by means of pulse amplitude modulation fluorometry, the photosynthetic efficiency of B. europaea specimens exposed in aquaria to the annual range of temperatures experienced in the field (13°C, 18°C, and 28°C, and two extreme temperatures expected for 2100 as a consequence of global warming (29°C and 32°C. The indicators of photosynthetic performance analyzed (maximum and effective quantum yield showed that maximum efficiency was reached at 20.0-21.6°C, slightly higher than the annual mean temperature in the field (18°C. Photosynthetic efficiency decreased from 20.0°C to 13°C and even more strongly from 21.6°C to 32°C. An unusual form of bleaching was observed, with a maximum zooxanthellae density at 18°C that strongly decreased from 18°C to 32°C. Chlorophyll a concentration per zooxanthellae cell showed an opposite trend as it was minimal at 18°C and increased from 18°C to 32°C. Since the areal chlorophyll concentration is the product of the zooxanthellae density and its cellular content, these trends resulted in a homogeneous chlorophyll concentration per coral surface across temperature treatments. This confirms that B. europaea photosynthesis is progressively depressed at temperatures >21.6°C, supporting previous hypotheses raised by the studies on growth and demography of this species. This study also confirms the threats posed to this species by the ongoing seawater warming.

  1. Vaginal sponge and spermicides

    Science.gov (United States)

    ... counter; Contraceptives - over the counter; Family planning - vaginal sponge; Contraception - vaginal sponge ... Spermicides and vaginal sponges do not work as well at preventing pregnancy as some other forms of birth control. However, using a spermicide ...

  2. Vaginal bleeding in pregnancy

    Science.gov (United States)

    Pregnancy - vaginal bleeding; Maternal blood loss - vaginal ... Up to 1 in 4 women have vaginal bleeding at some time during their pregnancy. Bleeding is more common in the first 3 months (first trimester), especially with twins.

  3. Vaginal yeast infection

    Science.gov (United States)

    Yeast infection - vagina; Vaginal candidiasis; Monilial vaginitis ... Most women have a vaginal yeast infection at some time. Candida albicans is a common type of fungus. It is often found in small amounts ...

  4. MRI of vaginal conditions

    International Nuclear Information System (INIS)

    Lopez, C.; Balogun, M.; Ganesan, R.; Olliff, J.F.

    2005-01-01

    Magnetic resonance imaging (MRI) has become an important part of the assessment of suspected vaginal pathology. This pictorial review demonstrates the MRI features and some of the histopathological findings of a variety of vaginal conditions. These may be congenital (total vaginal agenesis, partial vaginal agenesis, longitudinal vaginal septum, transverse vaginal septum), benign (Bartholin's cyst, diffuse vaginal inflammation, invasive endometriosis, ureterovaginal fistula, post-surgical appearances with the formation of a neovagina and adhesions) or malignant, usually due to extension or recurrence from another pelvic malignancy. In this paper, examples of the above are described and illustrated together with examples of the much rarer primary vaginal malignancies

  5. MRI of vaginal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, C. [Department of Radiology, Birmingham Women' s Hospital, Birmingham (United Kingdom)]. E-mail: carolina.lopez@bwhct.nhs.uk; Balogun, M. [Department of Radiology, Birmingham Women' s Hospital, Birmingham (United Kingdom); Ganesan, R. [Department of Histopathology, Birmingham Women' s Hospital, Birmingham (United Kingdom); Olliff, J.F. [University Hospital Birmingham, Birmingham (United Kingdom)

    2005-06-01

    Magnetic resonance imaging (MRI) has become an important part of the assessment of suspected vaginal pathology. This pictorial review demonstrates the MRI features and some of the histopathological findings of a variety of vaginal conditions. These may be congenital (total vaginal agenesis, partial vaginal agenesis, longitudinal vaginal septum, transverse vaginal septum), benign (Bartholin's cyst, diffuse vaginal inflammation, invasive endometriosis, ureterovaginal fistula, post-surgical appearances with the formation of a neovagina and adhesions) or malignant, usually due to extension or recurrence from another pelvic malignancy. In this paper, examples of the above are described and illustrated together with examples of the much rarer primary vaginal malignancies.

  6. Vaginal Cancer Overview

    Science.gov (United States)

    ... are here Home > Types of Cancer > Vaginal Cancer Vaginal Cancer This is Cancer.Net’s Guide to Vaginal Cancer. Use the menu below to choose the ... social workers, and patient advocates. Cancer.Net Guide Vaginal Cancer Introduction Statistics Medical Illustrations Risk Factors and ...

  7. Vaginal bleeding between periods

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003156.htm Vaginal bleeding between periods To use the sharing features ... this page, please enable JavaScript. This article discusses vaginal bleeding that occurs between a woman's monthly menstrual ...

  8. Vaginal and Vulvar Cancer

    Science.gov (United States)

    VAGINAL & VULVAR CANCER Get the Facts About Gynecologic Cancer There are five main types of cancer that affect a woman’s reproductive organs: cervical, ovarian, uterine, vaginal, and vulvar. As a group, they are referred ...

  9. Management of aerobic vaginitis.

    Science.gov (United States)

    Tempera, Gianna; Furneri, Pio Maria

    2010-01-01

    Aerobic vaginitis is a new nonclassifiable pathology that is neither specific vaginitis nor bacterial vaginosis. The diversity of this microbiological peculiarity could also explain several therapeutic failures when patients were treated for infections identified as bacterial vaginosis. The diagnosis 'aerobic vaginitis' is essentially based on microscopic examinations using a phase-contrast microscope (at ×400 magnification). The therapeutic choice for 'aerobic vaginitis' should take into consideration an antibiotic characterized by an intrinsic activity against the majority of bacteria of fecal origin, bactericidal effect and poor/absent interference with the vaginal microbiota. Regarding the therapy for aerobic vaginitis when antimicrobial agents are prescribed, not only the antimicrobial spectrum but also the presumed ecological disturbance on the anaerobic and aerobic vaginal and rectal microbiota should be taken into a consideration. Because of their very low impact on the vaginal microbiota, kanamycin or quinolones are to be considered a good choice for therapy. Copyright © 2010 S. Karger AG, Basel.

  10. Problems in nonlinear acoustics: Pulsed finite amplitude sound beams, nonlinear acoustic wave propagation in a liquid layer, nonlinear effects in asymmetric cylindrical sound beams, effects of absorption on the interaction of sound beams, and parametric receiving arrays

    Science.gov (United States)

    Hamilton, Mark F.

    1990-12-01

    This report discusses five projects all of which involve basic theoretical research in nonlinear acoustics: (1) pulsed finite amplitude sound beams are studied with a recently developed time domain computer algorithm that solves the KZK nonlinear parabolic wave equation; (2) nonlinear acoustic wave propagation in a liquid layer is a study of harmonic generation and acoustic soliton information in a liquid between a rigid and a free surface; (3) nonlinear effects in asymmetric cylindrical sound beams is a study of source asymmetries and scattering of sound by sound at high intensity; (4) effects of absorption on the interaction of sound beams is a completed study of the role of absorption in second harmonic generation and scattering of sound by sound; and (5) parametric receiving arrays is a completed study of parametric reception in a reverberant environment.

  11. Vaginal microbiota in menopause

    OpenAIRE

    Martinus Tarina; Larisa Paramitha; Evita Halim Effendi; Shannaz Nadia Yusharyahya; Hanny Nilasari; Wresti Indriatmi

    2016-01-01

    The human vagina together with its resident, microbiota, comprise a dynamic ecosystem. Normal microbiota is dominated by Lactobacillus species, and pathogen microbiota such as Gardnerella species and Bacteroides species can occur due to decrease in Lactobacillus domination. Lactobacillus plays an essential role in keeping normal vaginal microbiota in balance. Vaginal microbiota adapts to pH change and hormonal value. Changes in the vaginal microbiota over a woman’s lifespan will influence the...

  12. Charge-storage techniques for pulse-height analysis; Techniques de stockage electrostatique pour l'analyse en amplitude d'impulsion; Metod nakopleniya zaryada dlya amplitudnogo analiza impul'sov; Tecnicas de almacenamiento de cargas para analisis de amplitud de impulsos

    Energy Technology Data Exchange (ETDEWEB)

    Costrell, L; Brueckmann, R E [National Bureau of Standards, Washington, DC (United States)

    1962-04-15

    The low-duty cycles of many pulsed accelerators make high pulse rates necessary within the bursts in order to accumulate adequate data in a reasonable time. Not only do economic factors, as influenced by expensive machine time, dictate the use of high pulse rates, but purely technical considerations often make experiments unfeasible unless the pulses per burst are so numerous as to exclude the use of conventional pulse-height analysers. For these reasons much effort has been devoted to the development of high-speed pulse-height analysers for use with pulsed accelerators. Much of this work has been directed toward producing what we term a ''charge-storage analyser'' based on work conducted at the National Bureau of Standards. We have developed a charge-storage analyser that operates with the NBS 180-MeV synchrotron on a nuclear-absorption experiment for which the obstacles would otherwise be formidable. The analyser uses temporary electrostatic storage for the accumulation of pulse-height data during the machine bursts. During the dead intervals between bursts the contents of the temporary storage are analysed and transferred into a conventional magnetic core memory. The use of this technique for nanosecond pulses is discussed and data is presented to show its feasibility. (author) [French] Comme la partie du cycle de travail effectivement utilisee dans un grand nombre d'accelerateurs nucleaires puises est tres faible, il faut employer des frequences de repetition elevees pendant les bouffees, si l'on veut accumuler suffisamment de resultats en un temps raisonnable. Non seulement les facteurs economiques - influences par l'importance du temps de fonctionnement d'une machine couteuse - imposent des frequences de repetition elevees mais les experiences sont bien souvent irrealisables pour des raisons purement techniques, a moins que le nombre d'impulsions utilisees ne permettent de se passer d'analyseurs classiques des amplitudes d'impulsion. C'est pourquoi on a

  13. Vaginitis: diagnosis and management.

    Science.gov (United States)

    Faro, S

    1996-01-01

    The various conditions that give rise to vaginitis include specific and nonspecific entities, such as candidiasis, trichomoniasis, bacterial vaginosis, group B streptococcal vaginitis, purulent vaginitis, volvodynia, and vestibulitis. The patient with chronic vaginitis usually develops this condition because of a misdiagnosis. It is critical that patients who have chronic vaginitis be thoroughly evaluated to determine if there is a specific etiology and whether their condition is recurrent or persistent, or is a reinfection. This also must include obtaining a detailed history, beginning with the patient's best recollection of when she felt perfectly normal. The physician must have an understanding of a healthy vaginal ecosystem and what mechanisms are in place to maintain the equilibrium. The vaginal ecosystem is a complex system of micro-organisms interacting with host factors to maintain its equilibrium. The endogenous microflora consists of a variety of bacteria, which include aerobic, facultative and obligate anaerobic bacteria. These organisms exist in a commensal, synergistic or antagonistic relationship. Therefore, it is important to understand what factors control the delicate equilibrium of the vaginal ecosystem, and which factors, both endogenous and exogenous, can disrupt this system. It is also important for the physician to understand that when a patient has symptoms of vaginitis it is not always due to an infectious etiology. There are situations in which an inflammatory reaction occurs but the specific etiology may not be determined. Thus, it is important that the physician not rush through the history or the examination.

  14. Vaginal or uterine bleeding - overview

    Science.gov (United States)

    ... and other menstrual conditions; Abnormal menstrual periods; Abnormal vaginal bleeding ... There are many causes of abnormal vaginal bleeding. HORMONES ... Doctors call the problem abnormal uterine bleeding (AUB) . AUB ...

  15. Vaginal toxic shock reaction triggering desquamative inflammatory vaginitis.

    Science.gov (United States)

    Pereira, Nigel; Edlind, Thomas D; Schlievert, Patrick M; Nyirjesy, Paul

    2013-01-01

    The study aimed to report 2 cases of desquamative inflammatory vaginitis associated with toxic shock syndrome toxin 1 (TSST-1)-producing Staphylococcus aureus strains. Case report of 2 patients, 1 with an acute and 1 with a chronic presentation, diagnosed with desquamative inflammatory vaginitis on the basis of clinical findings and wet mount microscopy. Pretreatment and posttreatment vaginal bacterial and yeast cultures were obtained. Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial culture results after oral antibiotic therapy were negative. Desquamative inflammatory vaginitis may be triggered through TSST-1-mediated vaginal toxic shock reaction.

  16. Vaginal drug distribution modeling.

    Science.gov (United States)

    Katz, David F; Yuan, Andrew; Gao, Yajing

    2015-09-15

    This review presents and applies fundamental mass transport theory describing the diffusion and convection driven mass transport of drugs to the vaginal environment. It considers sources of variability in the predictions of the models. It illustrates use of model predictions of microbicide drug concentration distribution (pharmacokinetics) to gain insights about drug effectiveness in preventing HIV infection (pharmacodynamics). The modeling compares vaginal drug distributions after different gel dosage regimens, and it evaluates consequences of changes in gel viscosity due to aging. It compares vaginal mucosal concentration distributions of drugs delivered by gels vs. intravaginal rings. Finally, the modeling approach is used to compare vaginal drug distributions across species with differing vaginal dimensions. Deterministic models of drug mass transport into and throughout the vaginal environment can provide critical insights about the mechanisms and determinants of such transport. This knowledge, and the methodology that obtains it, can be applied and translated to multiple applications, involving the scientific underpinnings of vaginal drug distribution and the performance evaluation and design of products, and their dosage regimens, that achieve it. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Analysis of Vaginal Cell Populations during Experimental Vaginal Candidiasis

    OpenAIRE

    Fidel, Paul L.; Luo, Wei; Steele, Chad; Chabain, Joseph; Baker, Marc; Wormley, Floyd

    1999-01-01

    Studies with an estrogen-dependent murine model of vaginal candidiasis suggest that local cell-mediated immunity (CMI) is more important than systemic CMI for protection against vaginitis. The present study, however, showed that, compared to uninfected mice, little to no change in the percentage or types of vaginal T cells occurred during a primary vaginal infection or during a secondary vaginal infection where partial protection was observed. Furthermore, depletion of polymorphonuclear leuko...

  18. Amplitude-modulated fiber-ring laser

    DEFF Research Database (Denmark)

    Caputo, J. G.; Clausen, Carl A. Balslev; Sørensen, Mads Peter

    2000-01-01

    Soliton pulses generated by a fiber-ring laser are investigated by numerical simulation and perturbation methods. The mathematical modeling is based on the nonlinear Schrödinger equation with perturbative terms. We show that active mode locking with an amplitude modulator leads to a self......-starting of stable solitonic pulses from small random noise, provided the modulation depth is small. The perturbative analysis leads to a nonlinear coupled return map for the amplitude, phase, and position of the soliton pulses circulating in the fiber-ring laser. We established the validity of this approach...

  19. Vaginal Cancer—Patient Version

    Science.gov (United States)

    Two-thirds of vaginal cancer cases are caused by human papillomavirus (HPV). Vaccines that protect against infection with HPV may reduce the risk of vaginal cancer. When found early, vaginal cancer can often be cured. Start here to find information on vaginal cancer treatment and research.

  20. Vaginal delivery - discharge

    Science.gov (United States)

    Pregnancy - discharge after vaginal delivery ... You may have bleeding from your vagina for up to 6 weeks. Early on, you may pass some small clots when you first get up. Bleeding will slowly become ...

  1. Can Vaginitis Be Prevented?

    Science.gov (United States)

    ... examples of safe sex. 1 Centers for Disease Control and Prevention. (2010). Self-study STD module—vaginitis . ... Halvorson New Chief of Gynecologic Health and Disease Branch Division of Epidemiology, Statistics, ...

  2. Vaginal microbiota in menopause

    Directory of Open Access Journals (Sweden)

    Martinus Tarina

    2016-12-01

    Full Text Available The human vagina together with its resident, microbiota, comprise a dynamic ecosystem. Normal microbiota is dominated by Lactobacillus species, and pathogen microbiota such as Gardnerella species and Bacteroides species can occur due to decrease in Lactobacillus domination. Lactobacillus plays an essential role in keeping normal vaginal microbiota in balance. Vaginal microbiota adapts to pH change and hormonal value. Changes in the vaginal microbiota over a woman’s lifespan will influence the colonization of pathogenic microbes. They include changes in child, puberty, reproductive state, menopause, and postmenopause. Estrogen levels change will affect the colonization of pathogenic microbium, leading to genitourinary syndrome of menopause. Vulvovaginal atrophy is often found in postmenopausal women, and dominated by L. iners, Anaerococcus sp, Peptoniphilus sp, Prevotella sp, and Streptococcus sp. The normal vaginal microbiota’s imbalance in menopause will cause diseases such as bacterial vaginosis, and recurrent vulvovaginal candidiasis due to hormonal therapies. Changes in the vaginal microbiota due to bacterial vaginosis are characterized by decrease in H2O2-producing Lactobacillus. They are also caused by the increase in numbers and concentration of Gardnerella vaginalis, Mycoplasma hominis, and other anaerob species such as Peptostreptococci, Prevotella spp, and Mobiluncus spp.

  3. After vaginal delivery - in the hospital

    Science.gov (United States)

    After vaginal birth; Pregnancy - after vaginal delivery; Postpartum care - after vaginal delivery ... blood pressure, heart rate, and the amount of vaginal bleeding Check to make sure your uterus is ...

  4. Vaginal Cancer—Health Professional Version

    Science.gov (United States)

    Vaginal cancer is often squamous cell carcinoma. Other types of vaginal cancer are adenocarcinoma, melanoma, and sarcoma. Infection with certain types of human papillomavirus (HPV) causes most vaginal cancer. Find evidence-based information on vaginal cancer treatment and research.

  5. Programmable pulse generator

    International Nuclear Information System (INIS)

    Xue Zhihua; Lou Binqiao; Duan Xiaohui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  6. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis

    OpenAIRE

    Evelyn Kaambo; Evelyn Kaambo; Evelyn Kaambo; Charlene Africa; Ramadhani Chambuso; Ramadhani Chambuso; Jo-Ann Shelley Passmore; Jo-Ann Shelley Passmore; Jo-Ann Shelley Passmore

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low...

  7. Aerobic vaginitis in pregnancy.

    Science.gov (United States)

    Donders, Ggg; Bellen, G; Rezeberga, D

    2011-09-01

    Aerobic vaginitis (AV) is an alteration in vaginal bacterial flora that differs from bacterial vaginosis (BV). AV is characterised by an abnormal vaginal microflora accompanied by an increased localised inflammatory reaction and immune response, as opposed to the suppressed immune response that is characteristic of BV. Given the increased local production of interleukin (IL)-1, IL-6 and IL-8 associated with AV during pregnancy, not surprisingly AV is associated with an increased risk of preterm delivery, chorioamnionitis and funisitis of the fetus. There is no consensus on the optimal treatment for AV in pregnant or non-pregnant women, but a broader spectrum drug such as clindamycin is preferred above metronidazole to prevent infection-related preterm birth. The exact role of AV in pregnancy, the potential benefit of screening, and the use of newer local antibiotics, disinfectants, probiotics and immune modulators need further study. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

  8. Vaginal itching and discharge - child

    Science.gov (United States)

    Pruritus vulvae; Itching - vaginal area; Vulvar itching; Yeast infection - child ... Common causes of vaginal itching and discharge in young girls include: Chemicals such as perfumes and dyes in detergents, fabric softeners, creams, ointments, ...

  9. Vaginal bleeding in late pregnancy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000627.htm Vaginal bleeding in late pregnancy To use the sharing ... JavaScript. One out of 10 women will have vaginal bleeding during their 3rd trimester. At times, it ...

  10. Analysis of Vaginal Cell Populations during Experimental Vaginal Candidiasis

    Science.gov (United States)

    Fidel, Paul L.; Luo, Wei; Steele, Chad; Chabain, Joseph; Baker, Marc; Wormley, Floyd

    1999-01-01

    Studies with an estrogen-dependent murine model of vaginal candidiasis suggest that local cell-mediated immunity (CMI) is more important than systemic CMI for protection against vaginitis. The present study, however, showed that, compared to uninfected mice, little to no change in the percentage or types of vaginal T cells occurred during a primary vaginal infection or during a secondary vaginal infection where partial protection was observed. Furthermore, depletion of polymorphonuclear leukocytes (PMN) had no effect on infection in the presence or absence of pseudoestrus. These results indicate a lack of demonstrable effects by systemic CMI or PMN against vaginitis and suggest that if local T cells are important, they are functioning without showing significant increases in numbers within the vaginal mucosa during infection. PMID:10338532

  11. Is vaginal hyaluronic acid as effective as vaginal estriol for vaginal dryness relief?

    Science.gov (United States)

    Stute, Petra

    2013-12-01

    In a multicenter, randomized, controlled, open-label, parallel- group trial hyaluronic acid vaginal gel (Hyalofemme) was compared to estriol vaginal cream (Ovestin) in women with vaginal dryness due to various causes. A total of 144 supposedly postmenopausal women below age 70 years were randomized in a 1:1 ratio to either receive hyaluronic acid vaginal gel (5 g per application) or estriol vaginal cream (0.5 g cream per application = 0.5 mg estriol) every 3 days for a total of ten applications, respectively. Exclusion criteria included vaginal infections, conventional contraindications to estrogens, use of vaginal products other than the investigational compounds, being unmarried, pregnant, or breastfeeding. The aim of the study was to test for non-inferiority of hyaluronic acid vaginal gel compared to estriol vaginal cream. The primary efficacy end point was the percentage (%) improvement in vaginal dryness, with the secondary end points being the percentage (%) improvements in vaginal itching, burning, and dyspareunia. Efficacy was assessed by using a visual analog scale (VAS) (0-10; 0 = absent, 10 = intolerable) at baseline (V0), during telephone contact after the third administration (V1), and at the final visit after the tenth administration (V2). Safety parameters included vaginal pH, endometrial thickness, and a vaginal smear for vaginal microecosystem assessment. Adverse events were recorded according to international guidelines. 133 women completed the study. At baseline, participants' characteristics did not differ significantly. Mean age was 54 years, time since menopause was 5 years on average, and cause of menopause was mostly natural. However, mean menstrual cycle days were also reported, although according to inclusion criteria only postmenopausal women were eligible for the study. At V1, an improvement in vaginal dryness was reported by about 49 % of women using hyaluronic acid vaginal gel, and by 53 % of women using estriol vaginal cream (p = 0

  12. Brachytherapy at the Institut Gustave-Roussy: Personalized vaginal mould applicator: technical modification and improvement

    International Nuclear Information System (INIS)

    Albano, M.; Dumas, I.; Haie-Meder, C.

    2008-01-01

    Brachytherapy plays an important role in the treatment of patients with gynaecological cancers. At the Institut Gustave-Roussy, the technique of vaginal mould applicator has been used for decades. This technique allows a personalized tailored irradiation, integrating tumour shape, size and extension and vaginal anatomy. Vaginal expansion reduces the dose to the vaginal mucosa and to the organs at risk. We report a modification of the material used for vaginal mould manufacture. The advantages of the new material are a lighter weight, and transparency allowing a better accuracy in the placement of catheters for radioactive sources. This material is applicable for low dose-rate, pulse dose-rate and high dose-rate brachytherapy. Since 2001, more than 700 vaginal moulds have been manufactured with this new approach without any intolerance. (authors)

  13. Menopause and the vaginal microbiome.

    Science.gov (United States)

    Muhleisen, Alicia L; Herbst-Kralovetz, Melissa M

    2016-09-01

    For over a century it has been well documented that bacteria in the vagina maintain vaginal homeostasis, and that an imbalance or dysbiosis may be associated with poor reproductive and gynecologic health outcomes. Vaginal microbiota are of particular significance to postmenopausal women and may have a profound effect on vulvovaginal atrophy, vaginal dryness, sexual health and overall quality of life. As molecular-based techniques have evolved, our understanding of the diversity and complexity of this bacterial community has expanded. The objective of this review is to compare the changes that have been identified in the vaginal microbiota of menopausal women, outline alterations in the microbiome associated with specific menopausal symptoms, and define how hormone replacement therapy impacts the vaginal microbiome and menopausal symptoms; it concludes by considering the potential of probiotics to reinstate vaginal homeostasis following menopause. This review details the studies that support the role of Lactobacillus species in maintaining vaginal homeostasis and how the vaginal microbiome structure in postmenopausal women changes with decreasing levels of circulating estrogen. In addition, the associated transformations in the microanatomical features of the vaginal epithelium that can lead to vaginal symptoms associated with menopause are described. Furthermore, hormone replacement therapy directly influences the dominance of Lactobacillus in the microbiota and can resolve vaginal symptoms. Oral and vaginal probiotics hold great promise and initial studies complement the findings of previous research efforts concerning menopause and the vaginal microbiome; however, additional trials are required to determine the efficacy of bacterial therapeutics to modulate or restore vaginal homeostasis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Vaginal health in contraceptive vaginal ring users - A review.

    Science.gov (United States)

    Lete, Iñaki; Cuesta, María C; Marín, Juan M; Guerra, Sandra

    2013-08-01

    To provide an overview of the available data from clinical studies of vaginal conditions in women who use a vaginal ring as a contraceptive. A systematic review of the literature. Millions of women have already used the ethylene vinyl acetate vaginal ring that releases ethinylestradiol and etonogestrel for contraception. Because of its small size, more than four out of five women using the ring report that they do not feel it, even during sexual intercourse. No colposcopic or cytological changes have been observed in users, although approximately 10% have increased vaginal discharge. While in vitro studies have shown adhesion of Candida yeasts to the vaginal ring surface, clinical studies have not demonstrated a greater incidence of Candida infections compared to users of equivalent oral contraceptives. Some clinical studies suggest a lower incidence of bacterial vaginosis. No interaction exists between concomitant use of the vaginal ring and other drugs or products for vaginal use. The use of a contraceptive vaginal ring does not alter the vaginal ecosystem and therefore does not substantially affect vaginal health.

  15. Diphoton generalized distribution amplitudes

    International Nuclear Information System (INIS)

    El Beiyad, M.; Pire, B.; Szymanowski, L.; Wallon, S.

    2008-01-01

    We calculate the leading order diphoton generalized distribution amplitudes by calculating the amplitude of the process γ*γ→γγ in the low energy and high photon virtuality region at the Born order and in the leading logarithmic approximation. As in the case of the anomalous photon structure functions, the γγ generalized distribution amplitudes exhibit a characteristic lnQ 2 behavior and obey inhomogeneous QCD evolution equations.

  16. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis.

    Science.gov (United States)

    Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial "health" in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery.

  17. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis

    Directory of Open Access Journals (Sweden)

    Evelyn Kaambo

    2018-03-01

    Full Text Available A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV and bacterial vaginosis (BV. The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial “health” in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery.

  18. Pyomyositis after vaginal delivery.

    LENUS (Irish Health Repository)

    Gaughan, Eve

    2011-01-01

    Pyomyositis is a purulent infection of skeletal muscle that arises from haematogenous spread, usually with abscess formation. It can develop after a transient bacteraemia of any cause. This type of infection has never been reported before in the literature after vaginal delivery. A 34-year-old woman had progressive severe pain in the left buttock and thigh and weakness in the left lower limb day 1 post spontaneous vaginal delivery. MRI showed severe oedema of the left gluteus, iliacus, piriformis and adductor muscles of the left thigh and a small fluid collection at the left hip joint. She was diagnosed with pyomyositis. She had fever of 37.9°C immediately postpartum and her risk factors for bacteraemia were a mild IV cannula-associated cellulitis and labour itself. She required prolonged treatment with antibiotics before significant clinical improvement was noted.

  19. Vaginal microbicides and teenagers.

    Science.gov (United States)

    Rupp, Richard E; Rosenthal, Susan L

    2003-10-01

    Sexually active teens are at significant risk from sexually transmitted infections and girls and women bear the greatest burden of these infections. New methods, such as vaginal microbicides, would provide female controlled options. Microbicides are currently in development and thus it is timely to discuss the progress made and factors that may influence acceptability for teens. Microbicide development presents many challenges, and several different potential mechanisms of action are being explored. There is interest in these products from women and men, and specific preferences are being investigated. Adolescents, due to reproductive system immaturity, developing cognitive abilities and the psychosocial context of their relationships, present a special set of challenges in efforts to foster microbicide use. Vaginal microbicides are on the horizon. Further study into teen issues is required to develop successful strategies for marketing and encouraging adolescent use of microbicides.

  20. Effects of vaginal prolapse surgery and ageing on vaginal vascularization

    OpenAIRE

    Weber, M.A.

    2016-01-01

    Ageing affects pelvic floor anatomy and function, resulting in several disorders like pelvic organ prolapse (POP), lower urinary tract symptoms and vaginal atrophy (VA). In this thesis we searched for methods to link the function of pelvic organs to physiological changes. The effects of POP and vaginal prolapse surgery on vaginal vascularization and the influence of ageing and topical oestrogens on pelvic floor disorders were examined. The lack of knowledge regarding the effects of ageing on ...

  1. Two Photon Distribution Amplitudes

    International Nuclear Information System (INIS)

    El Beiyad, M.; Pire, B.; Szymanowski, L.; Wallon, S.

    2008-01-01

    The factorization of the amplitude of the process γ*γ→γγ in the low energy and high photon virtuality region is demonstrated at the Born order and in the leading logarithmic approximation. The leading order two photon (generalized) distribution amplitudes exhibit a characteristic ln Q 2 behaviour and obey new inhomogeneous evolution equations

  2. Amplitudes, acquisition and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bloor, Robert

    1998-12-31

    Accurate seismic amplitude information is important for the successful evaluation of many prospects and the importance of such amplitude information is increasing with the advent of time lapse seismic techniques. It is now widely accepted that the proper treatment of amplitudes requires seismic imaging in the form of either time or depth migration. A key factor in seismic imaging is the spatial sampling of the data and its relationship to the imaging algorithms. This presentation demonstrates that acquisition caused spatial sampling irregularity can affect the seismic imaging and perturb amplitudes. Equalization helps to balance the amplitudes, and the dealing strategy improves the imaging further when there are azimuth variations. Equalization and dealiasing can also help with the acquisition irregularities caused by shot and receiver dislocation or missing traces. 2 refs., 2 figs.

  3. Color guided amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Broedel, Johannes [Stanford Institute for Theoretical Physics and Department of Physics, Stanford University, Stanford, CA (United States); Dixon, Lance J. [SLAC National Accelerator Laboratory, Stanford University, Stanford, CA (United States)

    2012-07-01

    Amplitudes in gauge thoeries obtain contributions from color and kinematics. While these two parts of the amplitude seem to exhibit different symmetry structures, it turns out that they can be reorganized in a way to behave equally, which leads to the so-called color-kinematic dual representations of amplitudes. Astonishingly, the existence of those representations allows squaring to related gravitational theories right away. Contrary to the Kawaii-Levellen-Tye relations, which have been used to relate gauge theories and gravity previously, this method is applicable not only to tree amplitudes but also at loop level. In this talk, the basic technique is introduced followed by a discussion of the existence of color-kinematic dual representations for amplitudes derived from gauge theory actions which are deformed by higher-operator insertions. In addition, it is commented on the implications for deformed gravitational theories.

  4. Vaginal Discharge: What's Normal, What's Not

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Vaginal Discharge: What's Normal, What's Not KidsHealth / For Teens / ... Discharge: What's Normal, What's Not Print What Is Vaginal Discharge? Vaginal discharge is fluid that comes from ...

  5. Vaginitis: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish Vulvovaginitis - overview (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Vaginitis updates by ... Vaginitis test - wet mount Vulvovaginitis - overview Related Health Topics Trichomoniasis Vaginal Diseases Yeast Infections Other Languages Find ...

  6. Phase and amplitude detection system for the Stanford Linear Accelerator

    International Nuclear Information System (INIS)

    Fox, J.D.; Schwarz, H.D.

    1983-01-01

    A computer controlled phase and amplitude detection system to measure and stabilize the rf power sources in the Stanford Linear Accelerator is described. This system measures the instantaneous phase and amplitude of a 1 microsecond 2856 MHz rf pulse and will be used for phase feedback control and for amplitude and phase jitter detection. This paper discusses the measurement system performance requirements for the operation of the Stanford Linear Collider, and the design and implementation of the phase and amplitude detection system. The fundamental software algorithms used in the measurement are described, as is the performance of the prototype phase and amplitude detector system

  7. Vaginal pressure during daily activities before and after vaginal repair

    DEFF Research Database (Denmark)

    Mouritsen, L; Hulbaek, M; Brostrøm, S

    2007-01-01

    The objective of the study was to measure vaginal pressure during various daily activities in patients before and after vaginal surgery for pelvic organ prolapse, searching data for evidence-based activity guidelines. Vaginal pressure (VP) was studied in 23 patients during activities such as rest......, pelvic floor contraction (PFC), coughing, Valsalva, rising from sitting to standing and lifting 2 and 5 kg with four different lifting techniques. VP was measured before, 1-5 days and 4-6 weeks after vaginal repair. Mean VP was four to five times higher during coughing and Valsalva compared to PFC...... was not related to the type of vaginal repair. The results imply that post-operative counselling should concentrate more on treating chronic cough and constipation than restrictions of moderate physical activities....

  8. Red herring vaginal discharge.

    Science.gov (United States)

    Lee, Jun Hee; Pringle, Kirsty; Rajimwale, Ashok

    2013-09-18

    Labial hair tourniquet syndrome is a rare condition that can be easily misdiagnosed and ultimately lead to irreversible damage. An 11-year-old premenarche girl presented with a 5-day history of pain and swelling in the labia with associated vaginal discharge. The general practitioner treated her with clotrimazole without improvement. On examination, there was an oedematous swelling of the right labia with a proximal hair tourniquet. Local anaesthetic was applied and the hair removed with forceps. There was instant relief of pain and the discharge stopped within 24 h. The patient was sent home with a course of antibiotics.

  9. Pulse-width discriminators

    International Nuclear Information System (INIS)

    Budyashov, Yu.G.; Grebenyuk, V.M.; Zinov, V.G.

    1978-01-01

    A pulse duration discriminator is described which is intended for processing signals from multilayer scintillators. The basic elements of the scintillator are: an input gate, a current generator, an integrating capacitor, a Schmidt trigger and an anticoincidence circuit. The basic circuit of the discriminator and its time diagrams explaining its operating are given. The discriminator is based on microcircuits. Pulse duration discrimination threshold changes continuously from 20 to 100 ns, while its amplitude threshold changes within 20 to 100 mV. The temperature instability of discrimination thresholds (both in pulse width and in amplitude) is better than 0.1 per cent/deg C

  10. Finite Amplitude Ocean Waves

    Indian Academy of Sciences (India)

    IAS Admin

    wavelength, they are called shallow water waves. In the ... Deep and intermediate water waves are dispersive as the velocity of these depends on wavelength. This is not the ..... generation processes, the finite amplitude wave theories are very ...

  11. Real topological string amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Narain, K.S. [The Abdus Salam International Centre for Theoretical Physics (ICTP),Strada Costiera 11, Trieste, 34151 (Italy); Piazzalunga, N. [Simons Center for Geometry and Physics, State University of New York,Stony Brook, NY, 11794-3636 (United States); International School for Advanced Studies (SISSA) and INFN, Sez. di Trieste,via Bonomea 265, Trieste, 34136 (Italy); Tanzini, A. [International School for Advanced Studies (SISSA) and INFN, Sez. di Trieste,via Bonomea 265, Trieste, 34136 (Italy)

    2017-03-15

    We discuss the physical superstring correlation functions in type I theory (or equivalently type II with orientifold) that compute real topological string amplitudes. We consider the correlator corresponding to holomorphic derivative of the real topological amplitude G{sub χ}, at fixed worldsheet Euler characteristic χ. This corresponds in the low-energy effective action to N=2 Weyl multiplet, appropriately reduced to the orientifold invariant part, and raised to the power g{sup ′}=−χ+1. We show that the physical string correlator gives precisely the holomorphic derivative of topological amplitude. Finally, we apply this method to the standard closed oriented case as well, and prove a similar statement for the topological amplitude F{sub g}.

  12. Vaginal haemangioendothelioma: an unusual tumour.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Vaginal tumours are uncommon and this is a particularly rare case of a vaginal haemangioendothelioma in a 38-year-old woman. Initial presentation consisted of symptoms similar to uterovaginal prolapse with "something coming down". Examination under anaesthesia demonstrated a necrotic anterior vaginal wall tumour. Histology of the lesion revealed a haemangioendothelioma which had some features of haemangiopericytoma. While the natural history of vaginal haemangioendothelioma is uncertain, as a group, they have a propensity for local recurrence. To our knowledge this is the third reported case of a vaginal haemangioendothelioma. Management of this tumour is challenging given the paucity of literature on this tumour. There is a need to add rare tumours to our "knowledge bank" to guide management of these unusual tumours.

  13. Time-amplitude converter; Convertisseur temps-amplitude

    Energy Technology Data Exchange (ETDEWEB)

    Banner, M [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    It is normal in high energy physics to measure the time of flight of a particle in order to determine its mass. This can be done by the method which consists in transforming the time measurement into an analysis of amplitude, which is easier; a time-amplitude converter has therefore been built for this purpose. The apparatus here described uses a double grid control tube 6 BN 6 whose resolution time, as measured with a pulse generator, is 5 x 10{sup -11} s. The analysis of the response of a particle counter, made up of a scintillator and a photomultiplier, indicates that a time of resolution of 5 x 10{sup -10} s. can be obtained. A time of this order of magnitude is obtained experimentally with the converter. This converter has been used in the study of the time of flight of particles in a secondary beam of the accelerator Saturne. It has thus been possible to measure the energy spectrum of {pi}-mesons, of protons, and of deutons emitted from a polyethylene target bombarded by 1,4 and 2 GeV protons. (author) [French] Pour determiner la masse d'une particule, il est courant, en physique des hautes energies, de mesurer le temps de vol de cette particule. Cela peut etre fait par la methode qui consiste a transformer la mesure d'un temps en une analyse d'amplitude, plus aisee; aussi a-t-on, a cet effet, cree un convertisseur temps-amplitude. L'appareillage decrit dans cet article utilise un tube a double grille de commande 6 BN 6 dont le temps de resolution mesure avec un generateur d'impulsion est de 5.10{sup -11} s. L'analyse de la reponse d'un compteur de particules, constitue par un scintillateur et un photomultiplicateur, indique qu'un temps de resolution de 5.10{sup -10} s peut etre obtenu. Un temps de cet ordre est atteint experimentalement avec le convertisseur. Ce convertisseur a servi a l'etude du temps de vol des particules dans un faisceau secondaire de l'accelerateur Saturne. On a mesure ainsi le spectre d'energie des mesons {pi}, des protons, des deutons

  14. The effect of vaginal cream containing ginger in users of clotrimazole vaginal cream on vaginal candidiasis.

    Science.gov (United States)

    Shabanian, Sheida; Khalili, Sima; Lorigooini, Zahra; Malekpour, Afsaneh; Heidari-Soureshjani, Saeid

    2017-01-01

    Vulvovaginal candidiasis is one of the most common infections of the genital tract in women that causes many complications. Therefore, we examined the clinical effect of ginger cream along with clotrimazole compared to vaginal clotrimazole alone in this study. This double-blind clinical trial was conducted on 67 women admitted to the Gynecology Clinic of Hajar Hospital with vaginal candidiasis. The patients were divided randomly into two groups of 33 and 34 people. The diagnosis was made according to clinical symptoms, wet smear, and culture. Ginger-clotrimazole vaginal cream 1% and clotrimazole vaginal cream 1% were administered to groups 1 and 2, respectively, once a day for 7 days and therapeutic effects and symptoms were evaluated in readmission. Data analysis was performed using SPSS version 22, t -test and Chi-square. The mean value of variables itching ( P > 0.05), burning ( P > 0.05), and cheesy secretion ( P vaginal candidiasis.

  15. Episiotomy for vaginal birth

    Science.gov (United States)

    Carroli, Guillermo; Mignini, Luciano

    2014-01-01

    Background Episiotomy is done to prevent severe perineal tears, but its routine use has been questioned. The relative effects of midline compared with midlateral episiotomy are unclear. Objectives The objective of this review was to assess the effects of restrictive use of episiotomy compared with routine episiotomy during vaginal birth. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (March 2008). Selection criteria Randomized trials comparing restrictive use of episiotomy with routine use of episiotomy; restrictive use of mediolateral episiotomy versus routine mediolateral episiotomy; restrictive use of midline episiotomy versus routine midline episiotomy; and use of midline episiotomy versus mediolateral episiotomy. Data collection and analysis The two review authors independently assessed trial quality and extracted the data. Main results We included eight studies (5541 women). In the routine episiotomy group, 75.15% (2035/2708) of women had episiotomies, while the rate in the restrictive episiotomy group was 28.40% (776/2733). Compared with routine use, restrictive episiotomy resulted in less severe perineal trauma (relative risk (RR) 0.67, 95% confidence interval (CI) 0.49 to 0.91), less suturing (RR 0.71, 95% CI 0.61 to 0.81) and fewer healing complications (RR 0.69, 95% CI 0.56 to 0.85). Restrictive episiotomy was associated with more anterior perineal trauma (RR 1.84, 95% CI 1.61 to 2.10). There was no difference in severe vaginal/perineal trauma (RR 0.92, 95% CI 0.72 to 1.18); dyspareunia (RR 1.02, 95% CI 0.90 to 1.16); urinary incontinence (RR 0.98, 95% CI 0.79 to 1.20) or several pain measures. Results for restrictive versus routine mediolateral versus midline episiotomy were similar to the overall comparison. Authors’ conclusions Restrictive episiotomy policies appear to have a number of benefits compared to policies based on routine episiotomy. There is less posterior perineal trauma, less suturing and

  16. Amplitude-to-frequency converter of radioisotope instruments

    International Nuclear Information System (INIS)

    Demchenkov, V.P.; Korobkov, I.N.

    1988-01-01

    An amplitude-to-frequency converter designed for signal processing of radioisotope relay devices is descibed. The basic elements of the converter are a scaling amplifier, an analog-to-digital converter, a code-to-frequency converter, a null-organ, a delay unit and a clock-pulse generator. The designed amplitude-to-frequency converter takes into account a prior information about the signal shape of the energy spectrum. The converter processes input pulses of 0.10 V amplitude and duration more than 2μs. The energy channel number is 64

  17. Comparative study vagina mould/ fletcher applicator in MRI guided pulsed rate brachytherapy in patients reached by an uterine cervix carcinoma; Etude comparative moule vaginal/applicateur de fletcher en curietherapie de debit pulse guide par IRM chez les patientes atteintes d'un cancer du col uterin

    Energy Technology Data Exchange (ETDEWEB)

    Francois, G.; Dumas, I.; Mazeron, R.; Verezesan, O.; Monnier, L.; Vieillot, S.; Gensse, M.C.; Haie-Meder, C. [Institut Gustave-Roussy, 94 - Villejuif (France)

    2009-10-15

    This study began in february 2009 and included until today ten patients. twenty patients are planned. The analysis of preliminary results show a much higher tolerance for the vaginal cast device. The dosimetry data were the object of a preliminary study that seems demonstrate an equivalence of the both modalities, with differences concerning the doses to critical organs; The definitive result swill be presented with the data including the twenty planned patients. (N.C.)

  18. Vaginal oxytetracycline concentrations.

    Science.gov (United States)

    Thin, R N; Al Rawi, Z H; Simmons, P D; Treharne, J; Tabaqchali, S

    1979-01-01

    Although tetracycline preparations are widely used in departments of genitourinary medicine, or sexually transmitted diseases clinics, little is known of the concentrations of these preparations in genital secretions. For this reason a microbiological method was used for estimating oxytetracycline concentrations in vaginal secretions. These concentrations varied from 0.6 to 6.5 microgram/ml in 19 women who had had sexual contact with a man with non-specific urethritis and who were taking oxytetracycline dihydrate 250 mg four times daily. They were well in excess of the minimum inhibitory concentration of oxytetracycline (0.2 microgram/ml) for the strains of Chlamydia trachomatis isolated from the patients with positive culture results. Thus, oxytetracycline 250 mg four times daily appears to be a satisfactory regimen for the treatment of chlamydial genital infection in women. PMID:509190

  19. Radar transponder operation with compensation for distortion due to amplitude modulation

    Science.gov (United States)

    Ormesher, Richard C [Albuquerque, NM; Tise, Bertice L [Albuquerque, NM; Axline, Jr., Robert M.

    2011-01-04

    In radar transponder operation, a variably delayed gating signal is used to gate a received radar pulse and thereby produce a corresponding gated radar pulse for transmission back to the source of the received radar pulse. This compensates for signal distortion due to amplitude modulation on the retransmitted pulse.

  20. Measurement of amplitude fluctuations in a rapid response photomultiplier

    International Nuclear Information System (INIS)

    Raimbault, P.

    1961-01-01

    In order to measure amplitude fluctuations in a rapid response photomultiplier, two independent random variables are introduced which determine the shape of the anode pulse. The energy of each pulse, which depends directly on the gain and the variance, is the first variable; amplitude fluctuations, functions of the first variable, depend as well on the pulse width which in turn constitutes the second variable. The results obtained on the variations of the maximum impulse, using a steep-edged pulse broadening circuit, and those obtained on the statistical variations of the gain, are compared to show that the variance relative to the maximum amplitude of the signal is greater than that of the gain. Within the limits of these fluctuations are shown the contribution of the secondary emission coefficient of the first dynode, and that of the mean secondary emission coefficient of the multiplier. (author) [fr

  1. Amplitude and Ascoli analysis

    International Nuclear Information System (INIS)

    Hansen, J.D.

    1976-01-01

    This article discusses the partial wave analysis of two, three and four meson systems. The difference between the two approaches, referred to as amplitude and Ascoli analysis is discussed. Some of the results obtained with these methods are shown. (B.R.H.)

  2. Reinforcing Saccadic Amplitude Variability

    Science.gov (United States)

    Paeye, Celine; Madelain, Laurent

    2011-01-01

    Saccadic endpoint variability is often viewed as the outcome of neural noise occurring during sensorimotor processing. However, part of this variability might result from operant learning. We tested this hypothesis by reinforcing dispersions of saccadic amplitude distributions, while maintaining constant their medians. In a first experiment we…

  3. Charged particle interaction with a chirped electromagnetic pulse

    NARCIS (Netherlands)

    Khachatryan, A.G.; Boller, Klaus J.; van Goor, F.A.

    2003-01-01

    It is found that a charged particle can get a net energy gain from the interaction with an electromagnetic chirped pulse. Theoretically, the energy gain increases with the pulse amplitude and with the relative frequency variation in the pulse.

  4. Actinomyces associated with persistent vaginal granulation tissue.

    OpenAIRE

    Wai, Clifford Y; Nihira, Mikio A; Drewes, Peter G; Chang, Joe S; Siddiqui, Momin T; Hemsell, David L

    2005-01-01

    BACKGROUND: We report a case of symptomatic actinomycosis associated with vaginal suture erosion and granulation tissue refractory to conservative management, in an outpatient setting. CASE: Three months after total vaginal hysterectomy and uterosacral ligament vaginal vault suspension, a woman complained of painless, intermittent vaginal discharge and spotting. Despite cauterization of granulation tissue, vaginal spotting persisted for another month. On re-examination, braided polyester sutu...

  5. Drugs Approved for Vaginal Cancer

    Science.gov (United States)

    This page lists cancer drugs approved by the Food and Drug Administration (FDA) to prevent vaginal cancer. The list includes generic names and brand names. The drug names link to NCI’s Cancer Drug Information summaries.

  6. Urinary incontinence - vaginal sling procedures

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007376.htm Urinary incontinence - vaginal sling procedures To use the sharing features ... are types of surgeries that help control stress urinary incontinence . This is urine leakage that happens when you ...

  7. Phase and amplitude control system for Stanford Linear Accelerator

    International Nuclear Information System (INIS)

    Yoo, S.J.

    1983-01-01

    The computer controlled phase and amplitude detection system measures the instantaneous phase and amplitude of a 1 micro-second 2856 MHz rf pulse at a 180 Hz rate. This will be used for phase feedback control, and also for phase and amplitude jitter measurement. The program, which was originally written by John Fox and Keith Jobe, has been modified to improve the function of the system. The software algorithms used in the measurement are described, as is the performance of the prototype phase and amplitude detector system

  8. Vaginal rhinosporidiosis: a case report.

    Science.gov (United States)

    Jahan, S; Haque, M A; Nessa, F; Begum, A; Hasan, A H; Sen, S; Huq, M H

    2014-07-01

    The female genital tract is an extremely rare site for Rhinosporidiosis. Here we described a 13 year old girl who presented with a slow growing polypoid fleshy mass in the posterior vaginal wall near the orifice for 6 months with scanty bleeding from the mass. The girl was admitted to hospital with profuse watery vaginal discharge. Excision of the mass was followed by histopathological examination which confirmed the diagnosis Rhinosporidiosis.

  9. Laparoscopically assisted vaginal radical trachelectomy

    International Nuclear Information System (INIS)

    Bielik, T.; Karovic, M.; Trska, R.

    2013-01-01

    Purpose: Radical trachelectomy is a fertility-sparing procedure with the aim to provide adequate oncological safety to patients with cervical cancer while preserving their fertility. The purpose of this study was to retrospectively evaluate, in a series of 3 patients, the feasibility, morbidity, and safety of laparoscopically assisted vaginal radical trachelectomy for early cervical cancer. Patients and Methods: Three non consecutive patients with FIGO stage IA1 and IB1 cervical cancer was evaluated in a period of years 2008 - 2011. The patients underwent a laparoscopic pelvic lymphadenectomy and radical parametrectomy class II procedure according to the Piver classification. The section of vaginal cuff, trachelectomy, permanent cerclage and isthmo-vaginal anastomosis ware realised by vaginal approach. Results: The median operative time, the median blood loss and the mean number of resected pelvic nodes was comparable with published data. Major intraoperative complications did not occur and no patient required a blood transfusion. The median follow-up time was 33 (38-59) months. One vaginal recurrence occurred in 7 months after primary surgery. The patient was underwent a radicalisation procedure and adjuvant oncologic therapy and now is free of disease. Conclusions: Laparoscopically assisted vaginal radical trachelectomy (LAVRT)may be an alternative in fertility-preserving surgery for early cervical cancer. The procedure offers patients potential benefits of minimally invasive surgery with adequate oncological safety, but it should be reserved for oncologic surgeons trained in advanced laparoscopic procedures. (author)

  10. Recurrent vaginal discharge in children.

    Science.gov (United States)

    McGreal, Sharon; Wood, Paul

    2013-08-01

    Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  11. Light Meson Distribution Amplitudes

    CERN Document Server

    Arthur, R.; Brommel, D.; Donnellan, M.A.; Flynn, J.M.; Juttner, A.; de Lima, H.Pedroso; Rae, T.D.; Sachrajda, C.T.; Samways, B.

    2010-01-01

    We calculated the first two moments of the light-cone distribution amplitudes for the pseudoscalar mesons ($\\pi$ and $K$) and the longitudinally polarised vector mesons ($\\rho$, $K^*$ and $\\phi$) as part of the UKQCD and RBC collaborations' $N_f=2+1$ domain-wall fermion phenomenology programme. These quantities were obtained with a good precision and, in particular, the expected effects of $SU(3)$-flavour symmetry breaking were observed. Operators were renormalised non-perturbatively and extrapolations to the physical point were made, guided by leading order chiral perturbation theory. The main results presented are for two volumes, $16^3\\times 32$ and $24^3\\times 64$, with a common lattice spacing. Preliminary results for a lattice with a finer lattice spacing, $32^3\\times64$, are discussed and a first look is taken at the use of twisted boundary conditions to extract distribution amplitudes.

  12. [Operative vaginal deliveries training].

    Science.gov (United States)

    Dupuis, O

    2008-12-01

    The appropriate use of forceps, vacuums or spatulas facilitates the rapid delivery of foetuses faced with life-threatening situations. It also makes possible the relief of certain cases of prolonged second-stage labor. In France, operative vaginal delivery (OVD) accounts for approximately 10% of all births. OVD training aims to optimize maternal, as well as neonatal safety. It should enable trainees to indicate or contraindicate an OVD safely, as well as to choose the appropriate instrument, use it correctly, and master quality control principles. Traditional OVD training is confronted with both spatial and time-related limitations. Spatial constraints involve both the teacher and trainee who only have limited visual access to the pelvic canal, and the head of the foetus; the time constraint occurs whenever the OVD occurs in an emergency setting. These limitations have been further aggravated by new constraints: decreasing time dedicated to training (European safety rules prohibit work the day after night duty), increasing litigation, and constraints imposed by society. Training by means of simulation removes such limitations making it possible to both avoid exposing pregnant women to the hazards of traditional training, and adapt the training to the skills of each trainee. OVD training should include forceps, vacuums and the use of spatulas. The OVD skills of obstetricians should be audited regularly on both a personal and a confidential level. Such audits could be based on a method using a simulator. Prospective studies comparing traditional and simulation-based training should be encouraged.

  13. Definition of a type of abnormal vaginal flora that is distinct from bacterial vaginosis: aerobic vaginitis.

    Science.gov (United States)

    Donders, Gilbert G G; Vereecken, Annie; Bosmans, Eugene; Dekeersmaecker, Alfons; Salembier, Geert; Spitz, Bernard

    2002-01-01

    To define an entity of abnormal vaginal flora: aerobic vaginitis. Observational study. University Hospital Gasthuisberg, Leuven, Belgium. 631 women attending for routine prenatal care or attending vaginitis clinic. Samples were taken for fresh wet mount microscopy of vaginal fluid, vaginal cultures and measurement of lactate, succinate and cytokine levels in vaginal fluid. Smears deficient in lactobacilli and positive for clue cells were considered to indicate a diagnosis of bacterial vaginosis. Aerobic vaginitis was diagnosed if smears were deficient in lactobacilli, positive for cocci or coarse bacilli, positive for parabasal epithelial cells, and/or positive for vaginal leucocytes (plus their granular aspect). Genital complaints include red inflammation, yellow discharge, vaginal dyspareunia. Group B streptococci, escherichia coli, staphylococcus aureus and trichomonas vaginalis are frequently cultured. Vaginal lactate concentration is severely depressed in women with aerobic vaginitis, as in bacterial vaginosis, but vaginal succinate is not produced. Also in contrast to bacterial vaginosis, aerobic vaginitis produces a host immune response that leads to high production of interleukin-6, interleukin-1-beta and leukaemia inhibitory factor in the vaginal fluid. Aerobic vaginitis is associated with aerobic micro-organisms, mainly group B streptococci and E. coli. Its characteristics are different from those of bacterial vaginosis and elicit an important host response. The most severe form of aerobic vaginitis equals desquamative inflammatory vaginitis. In theory, aerobic vaginitis may be a better candidate than bacterial vaginosis as the cause of pregnancy complications, such as ascending chorioamnionitis, preterm rupture of the membranes and preterm delivery.

  14. Clinical Characteristics of Aerobic Vaginitis and Its Association to Vaginal Candidiasis, Trichomonas Vaginitis and Bacterial Vaginosis

    OpenAIRE

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-01-01

    ABSTRACT Aim of the work: Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Materials and methods: Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. Examinatio...

  15. Clinical characteristics of aerobic vaginitis and its association to vaginal candidiasis, trichomonas vaginitis and bacterial vaginosis.

    Science.gov (United States)

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-12-01

    Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. anamnesis, clinical, gynecological and microbiological examination of vaginal smear. The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from treatment of other vaginitis.

  16. Streptococcus agalactiae: a vaginal pathogen?

    Science.gov (United States)

    Maniatis, A N; Palermos, J; Kantzanou, M; Maniatis, N A; Christodoulou, C; Legakis, N J

    1996-03-01

    The significance of Streptococcus agalactiae as an aetiological agent in vaginitis was evaluated. A total of 6226 samples from women who presented with vaginal symptoms was examined. The presence of >10 leucocytes/high-power field (h.p.f.) was taken to be the criterion of active infection. S. agalactiae was isolated from 10.1% of these samples. The isolation rates of other common pathogens such as Candida spp., Gardnerella vaginalis and Trichomonas spp. were 54.1%, 27.2% and 4.2%, respectively, in the same group of patients. In contrast, the isolation rates of these micro-organisms in the group of patients who had no infection (S. agalactiae was isolated, it was the sole pathogen isolated (83%) and its presence was associated with an inflammatory response in 80% of patients. Furthermore, the relative risk of vaginal infection with S. agalactiae (2.38) in patients with purulent vaginal discharge was greater than that of Candida spp. infection (1.41) and lower than that of Trichomonas spp. infection (8.32). These data suggest that S. agalactiae in symptomatic women with microscopic evidence of inflammation should be considered a causative agent of vaginitis.

  17. Vaginal birth after C-section

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000589.htm Vaginal birth after C-section To use the sharing ... the same way again. Many women can have vaginal deliveries after having a C-section in the ...

  18. VBAC (Vaginal Birth After C-Section)

    Science.gov (United States)

    Vaginal birth after C-section (VBAC) Overview If you've delivered a baby by C-section and ... between scheduling a repeat C-section or attempting vaginal birth after C-section (VBAC). For many women, ...

  19. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  20. What is vaginal birth after cesarean (VBAC)?

    Science.gov (United States)

    ... Pinterest Email Print What is vaginal birth after cesarean (VBAC)? VBAC refers to vaginal delivery of a baby after a previous pregnancy was delivered by cesarean delivery. In the past, pregnant women who had ...

  1. Spontaneous rupture of vaginal enterocele

    DEFF Research Database (Denmark)

    Svendsen, J H; Galatius, H; Hansen, P K

    1985-01-01

    Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission.......Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission....

  2. Premenarchal, recurrent vaginal discharge associated with an incomplete obstructing longitudinal vaginal septum.

    Science.gov (United States)

    Hansen, Keith A; DeWitt, Jason

    2005-12-01

    To describe an unusual, premenarchal presentation of an obstructive vaginal anomaly. Case Report. University Medical Center. Premenarchal subject Vaginogram, vaginal septum resection. Vaginal septum resection with resolution of vaginal discharge. This case demonstrates some of the typical features of uterus didelphys bicollis with incomplete obstructing hemivagina, but had a unique presentation with premenarchal, recurrent vaginal discharge. Typically, patients with an obstructing mullerian anomaly present after menarche with pelvic pain and a mass. The vaginogram assists in the preoperative definition of abnormal anatomy which allows the surgeon to develop the most appropriate surgical approach. Resection of this incompletely obstructing vaginal septum resulted in resolution of the recurrent vaginal discharge.

  3. Evaluation of vaginal flora and antibiogram analysis in reproductive-age women with or without vaginitis in primary care settings

    OpenAIRE

    Alim, Ahmet; Çetin, Ali; Yıldız, Çağlar

    2009-01-01

    Aims: The treatment modalities of patients with vaginal discharge are generally related to their symptoms. The aim of this study was to evaluate vaginal flora and antibiogram analysis in reproductive-age women with or without vaginitis in primary care settings. Methods: Vaginal swabs were taken from 311 women who have vaginitis, and tested for the causative agents of vaginal discharge. The control group was 89 healthy women without vaginal discharge. Vaginal swaps were used in a commercial te...

  4. Effects of vaginal prolapse surgery and ageing on vaginal vascularization

    NARCIS (Netherlands)

    Weber, M.A.

    2016-01-01

    Ageing affects pelvic floor anatomy and function, resulting in several disorders like pelvic organ prolapse (POP), lower urinary tract symptoms and vaginal atrophy (VA). In this thesis we searched for methods to link the function of pelvic organs to physiological changes. The effects of POP and

  5. A New Method to Measure Vaginal Sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Introduction: Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. Aims: To develop a new method to measure vaginal sensibility. Methods: We

  6. A new method to measure vaginal sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. To develop a new method to measure vaginal sensibility. We developed a technique to measure the

  7. The Vaginal Microbiota of Guinea Pigs

    OpenAIRE

    Hafner, L. M.; Rush, C. M.; Timms, P.

    2011-01-01

    The vaginae of four guinea pigs were swabbed and samples cultured aerobically on horse blood agar, in 5 per cent carbon dioxide on MRS agar or anaerobically on anaerobic horse blood agar. Vaginal microbiota consisted almost exclusively of gram-positive bacteria including Corynebacterium, Streptococcus, Enterococcus, Staphylococcus and Lactobacillus species.Keywords: guinea pigs, vaginal microbiota, vaginal vaccines.

  8. Characterisation of the vaginal microflora of human ...

    African Journals Online (AJOL)

    Lactobacilli predominate normal vaginal microflora and are important in maintenance of vaginal health. The current study set out to identify and compare culture isolates of vaginal microflora of human immunodeficiency virus (HIV) positive (HIV+) and HIV negative (HIV-) women at different phases during menstrual cycle ...

  9. Ethinyl Estradiol and Etonogestrel Vaginal Ring

    Science.gov (United States)

    ... or infection of the vagina white or yellow vaginal discharge vaginal bleeding or spotting when it is not time ... Follow your doctor's directions for examining your breasts; report any lumps ... and ethinyl estradiol vaginal ring.Do not let anyone else use your ...

  10. Characterisation of the vaginal microflora of human ...

    African Journals Online (AJOL)

    Teresa kiama

    2014-02-26

    Feb 26, 2014 ... Lactobacilli predominate normal vaginal microflora and are important in maintenance of vaginal health. The current study set out to identify and compare culture isolates of vaginal microflora of human immunodeficiency virus (HIV) positive (HIV+) and HIV negative (HIV-) women at different phases during.

  11. Corrections to the large-angle scattering amplitude

    International Nuclear Information System (INIS)

    Goloskokov, S.V.; Kudinov, A.V.; Kuleshov, S.P.

    1979-01-01

    High-energy behaviour of scattering amplitudes is considered within the frames of Logunov-Tavchelidze quasipotential approach. The representation of scattering amplitude of two scalar particles, convenient for the study of its asymptotic properties is given. Obtained are corrections of the main value of scattering amplitude of the first and the second orders in 1/p, where p is the pulse of colliding particles in the system of the inertia centre. An example of the obtained formulas use for a concrete quasipotential is given

  12. Physiological measures of vaginal vasocongestion

    NARCIS (Netherlands)

    Laan, E.; Everaerd, W.

    1998-01-01

    This paper reviews reliability, specificity, and practical applicability of the two most promising and widely used methods for measuring blood flow within the vagina: the oxygenation-temperature method and vaginal photoplethysmography. It was concluded that the oxygenation-temperature method and

  13. MRI in distal vaginal atresia

    International Nuclear Information System (INIS)

    Hugosson, C.; Jorulf, H.; Bakri, Y.

    1991-01-01

    Magnetric resonance imaging in two young females with abdominal pain revealed vaginal atresia with massive hematocolpos but a normal cervix and uterine body. Information obtained with MRI was superior to ultrasound and CT and is suggested as the examination of choice prior to surgical correction. (orig.)

  14. Pulsed neutron sources at KAON

    International Nuclear Information System (INIS)

    Thorson, I.M.; Egelstaff, P.A.; Craddock, M.K.

    1991-01-01

    The proposed KAON Factory facility at TRIUMF consists of a number of synchrotrons and storage rings which offer proton beams of energies between 0.45 and 30 GeV with varying pulse amplitudes, widths and repetition rates. Various possibilities for feeding these beams to a pulsed neutron facility and their potential for future development are examined. The incremental cost of such a pulsed neutron facility is estimated approximately. (author)

  15. High Frequency Amplitude Detector for GMI Magnetic Sensors

    Directory of Open Access Journals (Sweden)

    Aktham Asfour

    2014-12-01

    Full Text Available A new concept of a high-frequency amplitude detector and demodulator for Giant-Magneto-Impedance (GMI sensors is presented. This concept combines a half wave rectifier, with outstanding capabilities and high speed, and a feedback approach that ensures the amplitude detection with easily adjustable gain. The developed detector is capable of measuring high-frequency and very low amplitude signals without the use of diode-based active rectifiers or analog multipliers. The performances of this detector are addressed throughout the paper. The full circuitry of the design is given, together with a comprehensive theoretical study of the concept and experimental validation. The detector has been used for the amplitude measurement of both single frequency and pulsed signals and for the demodulation of amplitude-modulated signals. It has also been successfully integrated in a GMI sensor prototype. Magnetic field and electrical current measurements in open- and closed-loop of this sensor have also been conducted.

  16. Pulse timing for cataclysmic variables

    International Nuclear Information System (INIS)

    Chester, T.J.

    1979-01-01

    It is shown that present pulse timing measurements of cataclysmic variables can be explained by models of accretion disks in these systems, and thus such measurements can constrain disk models. The model for DQ Her correctly predicts the amplitude variation of the continuum pulsation and can also perhaps explain the asymmetric amplitude of the pulsed lambda4686 emission line. Several other predictions can be made from the model. In particular, if pulse timing measurements that resolve emission lines both in wavelength and in binary phase can be made, the projected orbital radius of the white dwarf could be deduced

  17. Vaginal leiomyoma: MRI features with pathologic correlation

    Directory of Open Access Journals (Sweden)

    Avantika Gupta

    2015-06-01

    Full Text Available We present a rare case of vaginal leiomyoma presenting as prolapsed vaginal mass in a 45 years old woman. The leiomyoma was found to arise from the right lateral vaginal fornix with a vascular stalk. MRI showed homogenous hypointense signals on T1W1 and iso to hyperintense signals on T2W1 images with moderate heterogenous enhancement on post contrast images. It was enucleated via vaginal route and the histopathological examination confirmed the diagnosis of vaginal leiomyoma.

  18. [Aerobic vaginitis--diagnostic problems and treatment].

    Science.gov (United States)

    Romanik, Małgorzata; Wojciechowska-Wieja, Anna; Martirosian, Gayane

    2007-06-01

    The diagnostic criteria and treatment of aerobic vaginitis--AV--have been summarized in this review. An expansion of mixed aerobic microflora, especially Group B Streptococcus--GBS, Escherichia coli--E. coli, Enterococcus spp., and the development of inflammation of the vaginal mucous membrane due to a decreasing amount of Lactobacillus spp., have been observed in women with AV. Disruptions of the vaginal ecosystem during AV cause an increase in pH to >6, a decrease in lactates concentration and an increase in proinflammatory cytokines concentration in vaginal discharge. An optimal treatment scheme for AV, which includes antibacterial agents and simultaneously normalizes the vaginal ecosystem, has not been established until today.

  19. True vaginal prolapse in a bitch.

    Science.gov (United States)

    Alan, M; Cetin, Y; Sendag, S; Eski, F

    2007-08-01

    Frequently, vaginal fold prolapse is the protrusion of edematous vaginal tissue into and through the opening of the vulva occurring during proestrus and estrus stages of the sexual cycle. True vaginal prolapse may occur near parturition, as the concentration of serum progesterone declines and the concentration of serum oestrogen increases. In the bitch, this type of true vaginal prolapse is a very rare condition. This short communication describes a 5-year-old female, cross-breed dog in moderate condition, weighing 33 kg, with distocia and true vaginal prolapse. Abdominal palpation and transabdominal ultrasonography revealed live and dead foetuses in the uterine horns. One dead and four live fetuses were removed from uterus by cesarean section. The ovariohysterectomy was performed after repositioning the vaginal wall with a combination of traction from within the abdomen and external manipulation through the vulva. Re-occurrence of a vaginal prolapse was not observed and the bitch recovered completely after the surgical therapy. Compared to other vaginal disorders, vaginal prolapse is an uncommon condition in the bitch. In the present case, extreme tenesmus arising from distocia may have predisposed to the vaginal prolapse. The cause of dystocia was probably the disposition of the first foetus. We concluded that the vaginal prolapse was the result of dystocia in the present case.

  20. The effects of hyaluronic acid vaginal gel on the vaginal epithelium of ovariectomized rats.

    Science.gov (United States)

    Liu, Shuai-Bin; Liu, Shao-Li; Gan, Xiao-Ling; Zhou, Qin; Hu, Li-Na

    2015-03-01

    Hyaluronic acid is one of the best materials of water retention which can be used in vaginal atrophy. This study is to evaluate the role and mechanism of the hyaluronic acid vaginal gel (Hyalofemme) in the vaginal epithelium of ovariectomized rats. Sixty SD rats were randomly divided into control group (Sham ovariectomy, Sham-OVX), tendency group (ovariectomy, OVX), and experiment group (ovariectomy+Hyalofemme, OVX+Hyalofemme). The hyaluronic acid vaginal gel was administered local vaginal therapy to the experiment group with cytologicaly confirmed vaginal atrophy. The doses were adjusted by animal weight according to human dosage. After daily treatment for 14 days, VEGF and P-AKT activations were detected by Western blot in the experiment group. The hyaluronic acid vaginal gel proved to be very effective in the cytological reversal of vaginal atrophy but did not increase uterine weight. Vaginal microecosystem indicators were negative in the control group and the experiment group. By contrast, the indicators were positive in the tendency group. Hyaluronic acid vaginal gel is effective in the reversal of vaginal atrophy and is beneficial for improving vaginal microecosystem in the postmenopausal rat model. The hyaluronic acid vaginal gel can also improve the repair capacity of the vaginal epithelium.

  1. <3> OMEGA pulse-forming network

    CERN Multimedia

    1974-01-01

    Adjustement of the 3 W pulse-forming network of the SPS beam dumping system. When charged at 60 kV, this PFN gives 10 kA, 25 ms current pulses, with oscillations, superimposed on the pulse flat top, of an amplitude of +/- 1 Ka.

  2. Unifying relations for scattering amplitudes

    Science.gov (United States)

    Cheung, Clifford; Shen, Chia-Hsien; Wen, Congkao

    2018-02-01

    We derive new amplitudes relations revealing a hidden unity among a wideranging variety of theories in arbitrary spacetime dimensions. Our results rely on a set of Lorentz invariant differential operators which transmute physical tree-level scattering amplitudes into new ones. By transmuting the amplitudes of gravity coupled to a dilaton and two-form, we generate all the amplitudes of Einstein-Yang-Mills theory, Dirac-Born-Infield theory, special Galileon, nonlinear sigma model, and biadjoint scalar theory. Transmutation also relates amplitudes in string theory and its variants. As a corollary, celebrated aspects of gluon and graviton scattering like color-kinematics duality, the KLT relations, and the CHY construction are inherited traits of the transmuted amplitudes. Transmutation recasts the Adler zero as a trivial consequence of the Weinberg soft theorem and implies new subleading soft theorems for certain scalar theories.

  3. Hidden beauty in multiloop amplitudes

    International Nuclear Information System (INIS)

    Cachazo, Freddy; Spradlin, Marcus; Volovich, Anastasia

    2006-01-01

    Planar L-loop maximally helicity violating amplitudes in N = 4 supersymmetric Yang-Mills theory are believed to possess the remarkable property of satisfying iteration relations in L. We propose a simple new method for studying iteration relations for four-particle amplitudes which involves the use of certain linear differential operators and eliminates the need to fully evaluate any loop integrals. We carry out this procedure in explicit detail for the two-loop amplitude and prove that this method can be applied to any multiloop integral, allowing a conjectured iteration relation for any given amplitude to be tested up to polynomials in logarithms

  4. Two-Loop Splitting Amplitudes

    International Nuclear Information System (INIS)

    Bern, Z.

    2004-01-01

    Splitting amplitudes govern the behavior of scattering amplitudes at the momenta of external legs become collinear. In this talk we outline the calculation of two-loop splitting amplitudes via the unitarity sewing method. This method retains the simple factorization properties of light-cone gauge, but avoids the need for prescriptions such as the principal value or Mandelstam-Leibbrandt ones. The encountered loop momentum integrals are then evaluated using integration-by-parts and Lorentz invariance identities. We outline a variety of applications for these splitting amplitudes

  5. Two-loop splitting amplitudes

    International Nuclear Information System (INIS)

    Bern, Z.; Dixon, L.J.; Kosower, D.A.

    2004-01-01

    Splitting amplitudes govern the behavior of scattering amplitudes at the momenta of external legs become collinear. In this talk we outline the calculation of two-loop splitting amplitudes via the unitarity sewing method. This method retains the simple factorization properties of light-cone gauge, but avoids the need for prescriptions such as the principal value or Mandelstam-Leibbrandt ones. The encountered loop momentum integrals are then evaluated using integration-by-parts and Lorentz invariance identities. We outline a variety of applications for these splitting amplitudes

  6. AMPLITUDE AND TIME MEASUREMENT ASIC WITH ANALOG DERANDOMIZATION

    International Nuclear Information System (INIS)

    O CONNOR, P.; DE GERONIMO, G.; KANDASAMY, A.

    2002-01-01

    We describe a new ASIC for accurate and efficient processing of high-rate pulse signals from highly segmented detectors. In contrast to conventional approaches, this circuit affords a dramatic reduction in data volume through the use of analog techniques (precision peak detectors and time-to-amplitude converters) together with fast arbitration and sequencing logic to concentrate the data before digitization. In operation the circuit functions like a data-driven analog first-in, first-out (FIFO) memory between the preamplifiers and the ADC. Peak amplitudes of pulses arriving at any one of the 32 inputs are sampled, stored, and queued for readout and digitization through a single output port. Hit timing, pulse risetime, and channel address are also available at the output. Prototype chips have been fabricated in 0.35 micron CMOS and tested. First results indicate proper functionality for pulses down to 30 ns peaking time and input rates up to 1.6 MHz/channel. Amplitude accuracy of the peak detect and hold circuit is 0.3% (absolute). TAC accuracy is within 0.3% of full scale. Power consumption is less than 2 mW/channel. Compared with conventional techniques such as track-and-hold and analog memory, this new ASIC will enable efficient pulse height measurement at 20 to 300 times higher rates

  7. Fractional CO2 laser treatment for vaginal laxity: A preclinical study.

    Science.gov (United States)

    Kwon, Tae-Rin; Kim, Jong Hwan; Seok, Joon; Kim, Jae Min; Bak, Dong-Ho; Choi, Mi-Ji; Mun, Seok Kyun; Kim, Chan Woong; Ahn, Seungwon; Kim, Beom Joon

    2018-05-07

    Various studies have investigated treatment for vaginal laxity with microablative fractional carbon dioxide CO 2 laser in humans; however, this treatment has not yet been studied in an animal model. Herein, we evaluate the therapeutic effects of fractional CO 2 laser for tissue remodeling of vaginal mucosa using a porcine model, with the aim of improving vaginal laxity. The fractional CO 2 laser enables minimally invasive and non-incisional procedures. By precisely controlling the laser energy pulses, energy is sent to the vaginal canal and the introitus area to induce thermal denaturation and contraction of collagen. We examined the effects of fractional CO 2 laser on a porcine model via clinical observation and ultrasound measurement. Also, thermal lesions were histologically examined via hematoxylin-eosin staining, Masson's trichrome staining, and Elastica van Gieson staining and immunohistochemistry. The three treatment groups, which were determined according to the amount of laser-energy applied (60, 90, and 120 mJ), showed slight thermal denaturation in the vaginal mucosa, but no abnormal reactions, such as excessive hemorrhaging, vesicles, or erythema, were observed. Histologically, we also confirmed that the denatured lamina propria induced by fractional CO 2 laser was dose-dependently increased after laser treatment. The treatment groups also showed an increase in collagen and elastic fibers due to neocollagenesis and angiogenesis, and the vaginal walls became firmer and tighter because of increased capillary and vessel formation. Also, use of the fractional CO 2 laser increased HSP (heat shock protein) 70 and collagen type I synthesis. Our results show that microablative fractional CO 2 laser can produce remodeling of the vaginal connective tissue without causing damage to surrounding tissue, and the process of mucosa remodeling while under wound dressings enables collagen to increase and the vaginal wall to become thick and tightened. Lasers Surg. Med

  8. IAE pulsed electrostatic accelerator

    International Nuclear Information System (INIS)

    Afanas'ev, V.P.; Ganzhelyuk, M.L.; Kozlov, L.D.; Koltypin, E.A.; Molchanov, Yu.D.; Otroshchenko, G.A.; Yan'kov, G.B.

    1976-01-01

    The modernized pulse electrostatic accelerator using the klystron ion grouping and the beam interruption system prior to acceleration is described. The accelerator is modernized in order to improve parameters of a current pulse and to decrease the background in the measurement room. The ion beam of needed dimensions is obtained with the help of a high-frequency source and a beam grouping and deflection system. The general view of the beam grouping and deflection system is shown. The ion beam forming process is considered in detail. The modernized electrostatic accelerator permits to obtain a pulse current with a pulse length of 1.5 ns and an amplitude of 1.5 - 2 μA. With the repetition frequency of 2 MHz, the average target current is about 6 μA

  9. Concurrent chemoradiation for vaginal cancer.

    Directory of Open Access Journals (Sweden)

    David T Miyamoto

    Full Text Available BACKGROUND: It is not known whether the addition of chemotherapy to radiation therapy improves outcomes in primary vaginal cancer. Here, we review clinical outcomes in patients with primary vaginal cancer treated with radiation therapy (RT or concurrent chemoradiation therapy (CRT. METHODS: Seventy-one patients with primary vaginal cancer treated with definitive RT with or without concurrent chemotherapy at a single institution were identified and their records reviewed. A total of 51 patients were treated with RT alone; 20 patients were treated with CRT. Recurrences were analyzed. Overall survival (OS and disease-free survival (DFS rates were estimated using the Kaplan-Meier method. Cox regression analysis was performed. RESULTS: The median age at diagnosis was 61 years (range, 18-92 years and the median follow-up time among survivors was 3.0 years. Kaplan-Meier estimates for OS and DFS differed significantly between the RT and CRT groups (3-yr OS = 56% vs. 79%, log-rank p = 0.037; 3-yr DFS = 43% vs. 73%, log-rank p = 0.011. Twenty-three patients (45% in the RT group had a relapse at any site compared to 3 (15% in the CRT group (p = 0.027. With regard to the sites of first relapse, 10 patients (14% had local only, 4 (6% had local and regional, 9 (13% had regional only, 1 (1% had regional and distant, and 2 (3% had distant only relapse. On univariate analysis, the use of concurrent chemotherapy, FIGO stage, tumor size, and date of diagnosis were significant predictors of DFS. On multivariate analysis, the use of concurrent chemotherapy remained a significant predictor of DFS (hazard ratio 0.31 (95% CI, 0.10-0.97; p = 0.04. CONCLUSIONS: Vaginal cancer results in poor outcomes. Adequate radiation dose is essential to ensure curative management. Concurrent chemotherapy should be considered for vaginal cancer patients.

  10. Lactobacillus for Vaginal Microflora Correction

    Directory of Open Access Journals (Sweden)

    Saule Saduakhasova

    2014-12-01

    Full Text Available Introduction. Despite the significant progress made in prevention, diagnosis, and treatment, there is still a high rate of vaginal dysbiosis in Kazakh women. The use of antibiotics in the treatment of vaginal dysbiosis contributes to the elimination of pathogens as well as microflora, which can lead to a decrease in local immunity and more favorable conditions for infection spread. The most physiologically safe and promising method for the restoration of vaginal biocenosis is the use of probiotics administered by a vaginal route.Methods. We have allocated 64 of cultures of Lactobacillus from the vaginal epithelium of healthy women of reproductive age and women with diagnosed bacterial vaginosis (BV. Identification of cultures was performed by PCR analysis of 16S ribosomal RNA.  Evaluation of biological significance was determined by the following criteria: high antagonistic activity against Candida albicans, Escherichia coli, Serratia marcescens, Proteus mirabilis, Klebsiella ozaenae, and Staphylococcus aureus; and production of hydrogen peroxide, resistance to antibiotics, adhesive activity. We studied the symbiotic relationship of selected biologically active of cultures to each other and received options for consortiums with  properties of  probiotics through co-cultivation.Results. Results of genotyping  showed that the isolated lactobacilli belong to the seven species: L. fermentum, L. salivarius, L. gasseri, L. crispatus, L. jensenii, L. plantarum, and L. delbrueskii. L. fermentum, L. salivarius, L. gasseri, and L. jensenii occur in women with suspected BV. The highest percentage of occurrence in the vagina of healthy women was L. fermentum (28%. Most strains of lactobacilli possess high inhibitory activity for all test-strains, except Candida albicans (37.5%. 56% of studied cultures revealed high adhesion to human erythrocytes. All lactobacillus strains were resistant to metronidazole, 80% to kanamycin, 57%  to vancomycin, and

  11. Use of vaginal estrogen in Danish women

    DEFF Research Database (Denmark)

    Meaidi, Amani; Goukasian, Irina; Lidegaard, Oejvind

    2016-01-01

    INTRODUCTION: We know little about the use of vaginal estrogen in perimenopausal and postmenopausal women. We aimed to assess the prevalence of vaginal estrogen use in Denmark. MATERIAL AND METHODS: The study was designed as a nationwide cross-sectional study of all Danish women aged 40-79 years......, living in Denmark during the period 2007-2013. The Danish Prescription Register delivered data permitting us to assess the prevalence, age and regional geographical belonging of women purchasing prescribed vaginal estradiol. The number of women using over-the-counter vaginal estriol products...... was estimated from sale statistics from the same register. RESULTS: In 2013, 10.2% of all Danish women between 40 and 79 years of age used vaginal estradiol. The prevalence of women using this type of vaginal estrogen increased from 8.5% in year 2007 to 10.2% in 2013. The use peaked at 16.5% in women aged 60...

  12. Radiation tolerance of the vaginal mucosa

    International Nuclear Information System (INIS)

    Hintz, b.L.; Kagan, A.R.; Chan, P.; Gilbert, H.A.; Nussbaum, H.; Rao, A.R.; Wollin, M.

    1980-01-01

    Sixteen patients with cancer of the vagina that were controlled locally for a minimum of eighteen months after teletherpay (T) or brachytherapy (B) or both (T and B), were analyzed for radiation tolerance of the vaginal mucosa. The site of vaginal necrosis did not always coincide with the site of the tumor. The posterior wall appeared more vulnerable than the anterior or lateral walls. For the distal vaginal mucosa, necrosis requiring surgical intervention occurred following combined T and B, if summated rad exceeded9800. The upper vagina tolerated higher dosages. No patient surgery for upper vaginal necrosis even though summated (T and B) dosage up to 14,000 rad was applied. Placing radioactive needles on the surface of the vaginal cylinder with or without interstitial perincal needles should be avoided. Further accumulation of data is needed to define these vaginal mucosa tolerance limits more closely

  13. Bacterial vaginosis and vaginal yeast, but not vaginal cleansing, increase HIV-1 acquisition in African women

    NARCIS (Netherlands)

    van de Wijgert, Janneke H. H. M.; Morrison, Charles S.; Cornelisse, Peter G. A.; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A.; Padian, Nancy S.

    2008-01-01

    OBJECTIVE: To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. METHODS: A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women

  14. Vulvovaginitis and vaginal discharge in general practice

    Science.gov (United States)

    Shannon, W.

    1975-01-01

    Ninety-four patients with vulvovaginitis and vaginal discharge were assessed clinically and had vaginal swabs taken in an effort to establish a definite diagnosis. A high incidence of fungous infection was found while there was a surprisingly low incidence of Trichomonal vaginitis. These findings vary markedly from recent surveys in other countries (Delaha et al. (1964); Gray and Barnes, 1965; Desai et al., 1966). PMID:1223281

  15. A versatile programmable CAMAC random pulse generator

    International Nuclear Information System (INIS)

    Abdel-Aal, R.E.

    1991-01-01

    A new technique for generating linear pulses which can be random in both amplitude and time is described. With this technique, desired values for both pulse amplitude and spacing are set for the individual pulses by the software on a pulse-by-pulse basis. The versatility offered by this software programming allows a wide range of distributions to be obtained; with the user having close control on the distribution parameters. A number of such distributions may also be combined into a single output pulse stream. An implementation in a CAMAC module is presented. Both hardware and software aspects are described and typical performance results for amplitude and time distributions of the uniform and Gaussian type are given. Implications of using the pulser in a typical data acquisition environment on both the data acquisition and the pulser performance are considered. Typical applications are discussed together with some of the limitations. (orig.)

  16. Vaginal Mucosal Flap as a Sling Preservation for the Treatment of Vaginal Exposure of Mesh

    OpenAIRE

    Kim, Sea Young; Park, Jong Yeon; Kim, Han Kwon; Park, Chang Hoo; Kim, Sung Jin; Sung, Gi Teck; Park, Chang Myon

    2010-01-01

    Purpose Tension-free vaginal tape (TVT) procedures are used for the treatment of stress urinary incontinence in women. The procedures with synthetic materials can have a risk of vaginal erosion. We experienced transobturator suburethral sling (TOT) tape-induced vaginal erosion and report the efficacy of a vaginal mucosal covering technique. Materials and Methods A total of 560 female patients diagnosed with stress urinary incontinence underwent TOT procedures at our hospital between January 2...

  17. Vaginal rejuvenation using energy-based devices

    Directory of Open Access Journals (Sweden)

    Cheryl Karcher, MD

    2016-09-01

    Full Text Available Physiologic changes in a woman’s life, such as childbirth, weight fluctuations, and hormonal changes due to aging and menopause, may alter the laxity of the vaginal canal, damage the pelvic floor, and devitalize the mucosal tone of the vaginal wall. These events often lead to the development of genitourinary conditions such as stress urinary incontinence; vaginal atrophy; dryness; and physiologic distress affecting a woman’s quality of life, self-confidence, and sexuality. Various treatment modalities are currently available to manage these indications, varying from invasive vaginal surgery to more benign treatments like topical vaginal hormonal gels or hormone-replacement therapy. A new trend gaining momentum is the advent of energy-based devices for vaginal rejuvenation that apply thermal or nonthermal energy to the various layers of the vaginal tissue, stimulating collagen regeneration contracture of elastin fibers, neovascularization, and improved vaginal lubrication. This review aims to present the available technologies offering vaginal rejuvenation and the scientific evidence that underlines their safety and efficacy for this indication.

  18. Evaluation of common organisms causing vaginal discharge.

    Science.gov (United States)

    Khan, Shazia A; Amir, Fauzia; Altaf, Shagufta; Tanveer, Raazia

    2009-01-01

    Vaginal discharge is very common problem among females. Alteration in balance of normal vaginal organisms can cause the overgrowth of the bacteria that creates vaginal discharge. It is common among sexually active women yet there still remain gaps in our knowledge of this infectious disorder. To evaluate the frequency of bacterial vaginosis (BV), vaginal candidiasis (VC), vaginal trichomoniasis and Group B streptococcus in women complaining of vaginal discharge in our setup. A total of 100 women of reproductive age group with the complaint of vaginal discharge were included in the study. After filling proforma patients were examined by speculum examination and two high vaginal swabs (HVS) were collected aseptically from each patient. One swab was used for making wet mount for clue cells, pus cells and for motility of Trichomonas vaginalis. The other swab was used to check pH and Amine test. The growth was confirmed by Gram staining in each case. Gardnerrella vaginalis were isolated in 28%, Group B streptococcus in 5% and T. vaginolis in 4% of women. Gardnerella vaginalis causing BV is the most common cause of vaginal discharge in otherwise healthy women of reproductive age group in our setup.

  19. An Ultra Low Noise Self-Starting Pulse Generator

    DEFF Research Database (Denmark)

    Lasri, J.; Bilenca, A.; Dahan, D.

    2002-01-01

    We describe a self-starting optical pulse source generating 10 GHz, 15 ps pulses with an average jitter of 43 fs and a o.15% amplitude noise over a frequency range of 500 Hz - 1 MHz.......We describe a self-starting optical pulse source generating 10 GHz, 15 ps pulses with an average jitter of 43 fs and a o.15% amplitude noise over a frequency range of 500 Hz - 1 MHz....

  20. Dynamic Clinical Measurements of Voluntary Vaginal Contractions and Autonomic Vaginal Reflexes

    NARCIS (Netherlands)

    Broens, Paul M. A.; Spoelstra, Symen K.; Weijmar Schultz, Willibrord C. M.

    2014-01-01

    IntroductionThe vaginal canal is an active and responsive canal. It has pressure variations along its length and shows reflex activity. At present, the prevailing idea is that the vaginal canal does not have a sphincter mechanism. It is hypothesized that an active vaginal muscular mechanism exists

  1. The interaction between vaginal microbiota, cervical length, and vaginal progesterone treatment for preterm birth risk.

    Science.gov (United States)

    Kindinger, Lindsay M; Bennett, Phillip R; Lee, Yun S; Marchesi, Julian R; Smith, Ann; Cacciatore, Stefano; Holmes, Elaine; Nicholson, Jeremy K; Teoh, T G; MacIntyre, David A

    2017-01-19

    Preterm birth is the primary cause of infant death worldwide. A short cervix in the second trimester of pregnancy is a risk factor for preterm birth. In specific patient cohorts, vaginal progesterone reduces this risk. Using 16S rRNA gene sequencing, we undertook a prospective study in women at risk of preterm birth (n = 161) to assess (1) the relationship between vaginal microbiota and cervical length in the second trimester and preterm birth risk and (2) the impact of vaginal progesterone on vaginal bacterial communities in women with a short cervix. Lactobacillus iners dominance at 16 weeks of gestation was significantly associated with both a short cervix vaginal dysbiosis. A longitudinal characterization of vaginal microbiota (vaginal progesterone (400 mg/OD, n = 25) versus controls (n = 42). Progesterone did not alter vaginal bacterial community structure nor reduce L. iners-associated preterm birth (vaginal microbiota at 16 weeks of gestation is a risk factor for preterm birth, whereas L. crispatus dominance is protective against preterm birth. Vaginal progesterone does not appear to impact the pregnancy vaginal microbiota. Patients and clinicians who may be concerned about "infection risk" associated with the use of a vaginal pessary during high-risk pregnancy can be reassured.

  2. Design of a ns-pulse generator with microwave studio

    NARCIS (Netherlands)

    Huiskamp, T.; Voeten, S.J.; Pemen, A.J.M.

    2012-01-01

    In this paper we present a design approach of a nanosecond pulse generator by using CST MICROWAVE STUDIO R . Through detailed simulation we arrive at a design for a fast rise-time variable pulse duration pulse generator which is able to produce 1–10 nanosecond pulses with tens of kilovolt amplitude.

  3. Powerful nanosecond pulse train generator

    International Nuclear Information System (INIS)

    Isakov, I.F.; Logachev, E.I.; Opekunov, M.S.; Pechenkin, S.A.; Remnev, G.E.; Usov, Yu.P.

    1987-01-01

    A generator permitting to shape on the load pulsed with the repetition frequency of 10 3 -10 6 Hz and more is described. The amplitude of shaped voltage pulses is up to 150 kV at pulse duration equal to 50 ns. The generator comprises connected in-series with the load two shaping and two transmission lines realized on the base of the KVI-300 low-ohmic cable. The shaping lines are supplied from two independently connected pulse voltage generators for obtaining time interval between pulses > 10 -6 s; they may be also supplied from one generator for obtaining time interval -6 s. At the expense of reducing losses in the discharge circuit the amplitude of the second pulse grows with increase of time interval between pulses up to 300 ns, further on the curve flat-topping exists. The described generator is used in high-current accelerators, in which the primary negative pulse results in generation of explosive-emission plasma, and the second positive pulse provides ion beam shaping including ions of heavy metal used for production of a potential electrode. The generator multipulse mode is used for successive ion acceleration in the transport system

  4. Off-shell CHY amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Lam, C.S., E-mail: Lam@physics.mcgill.ca [Department of Physics, McGill University, Montreal, Q.C., H3A 2T8 (Canada); Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Yao, York-Peng, E-mail: yyao@umich.edu [Department of Physics, The University of Michigan Ann Arbor, MI 48109 (United States)

    2016-06-15

    The Cachazo–He–Yuan (CHY) formula for on-shell scattering amplitudes is extended off-shell. The off-shell amplitudes (amputated Green's functions) are Möbius invariant, and have the same momentum poles as the on-shell amplitudes. The working principles which drive the modifications to the scattering equations are mainly Möbius covariance and energy momentum conservation in off-shell kinematics. The same technique is also used to obtain off-shell massive scalars. A simple off-shell extension of the CHY gauge formula which is Möbius invariant is proposed, but its true nature awaits further study.

  5. Vaginal contraception--an update.

    Science.gov (United States)

    Edelman, D A; Thompson, S

    1982-04-01

    A number of new and innovative methods of vaginal contraceptive have been developed in recent years and are currently being evaluated. Some of these methods are described briefly and the available data on their safety and efficacy are presented. 3 types of contraceptive sponges have been developed--collagen sponge, intravaginal insert, and Secure sponge--and are now being evaluated. The collagen sponge, a cylindrical-shaped disk, exerts its contraceptive effect by acting as a physical barrier to the sperm and through its ability to absorb semen much in excess of its own weight. Preliminary data confirm the effectiveness of the sponge obtained from post-coital tests. The intravaginal insert (IVI) is made of a polyester material incorporating the spermicide nonoxynol-9. In a small clinical evaluation of the IVI, 49 women were followed up for 1 month. No pregnancies or unexpected adverse reactions were reported. The Secure sponge is made of polyurethane and incorporates 1 g of the spermicide nonoxynol-9. Its primary mode of action in preventing pregnancy is through the release of nonoxynol-9. In a multiclinic phase 2 evaluation of the Secure, which included 382 women, the 6-month gross life-table pregnancy rate was 3.8 +or- 1.3/100 women; the 6-month gross discontinuation rate for all reasons was 26.2 +or- 3.4/100 women. Sufficient data from the comparative trials of the Secure and Neo Sampoon foaming suppository studies conducted in Yugoslavia, Taiwan, and Bangladesh have been reported to the International Fertility Research Program (IFRP). The 12-month life-table rates for reasons leading to discontinuation of the contraceptive methods were not significantly different except for the category of "other personal reasons." The advantages Secure provides over other vaginal contraceptives are identified. Foaming vaginal suppositories similar to Neo Sampoon but containing 100 mg nonoxynol-9 are being developed and evaluated in the U.S. Clinical data on these products are

  6. More frequent vaginal orgasm is associated with experiencing greater excitement from deep vaginal stimulation.

    Science.gov (United States)

    Brody, Stuart; Klapilova, Katerina; Krejčová, Lucie

    2013-07-01

    Research indicated that: (i) vaginal orgasm (induced by penile-vaginal intercourse [PVI] without concurrent clitoral masturbation) consistency (vaginal orgasm consistency [VOC]; percentage of PVI occasions resulting in vaginal orgasm) is associated with mental attention to vaginal sensations during PVI, preference for a longer penis, and indices of psychological and physiological functioning, and (ii) clitoral, distal vaginal, and deep vaginal/cervical stimulation project via different peripheral nerves to different brain regions. The aim of this study is to examine the association of VOC with: (i) sexual arousability perceived from deep vaginal stimulation (compared with middle and shallow vaginal stimulation and clitoral stimulation), and (ii) whether vaginal stimulation was present during the woman's first masturbation. A sample of 75 Czech women (aged 18-36), provided details of recent VOC, site of genital stimulation during first masturbation, and their recent sexual arousability from the four genital sites. The association of VOC with: (i) sexual arousability perceived from the four genital sites and (ii) involvement of vaginal stimulation in first-ever masturbation. VOC was associated with greater sexual arousability from deep vaginal stimulation but not with sexual arousability from other genital sites. VOC was also associated with women's first masturbation incorporating (or being exclusively) vaginal stimulation. The findings suggest (i) stimulating the vagina during early life masturbation might indicate individual readiness for developing greater vaginal responsiveness, leading to adult greater VOC, and (ii) current sensitivity of deep vaginal and cervical regions is associated with VOC, which might be due to some combination of different neurophysiological projections of the deep regions and their greater responsiveness to penile stimulation. © 2013 International Society for Sexual Medicine.

  7. Vaginal hysterectomy, an outpatient procedure.

    Science.gov (United States)

    Engh, Marie Ellström; Hauso, Wenche

    2012-11-01

    To report our experience of treating women undergoing vaginal hysterectomy in an outpatient setting and to identify risk factors for hospital admission and women dissatisfied with care. Prospective observational report. department of obstetrics and gynecology, university hospital in Norway. 150 women who underwent vaginal hysterectomy at the outpatient clinic from February 2009 to April 2010. Perioperative data were collected prospectively and case notes were searched for complications. On the first postoperative day all women were contacted by telephone by a nurse. A visual analogue scale (VAS) was used to monitor pain and nausea during the stay at the outpatient clinic and the day after surgery. VAS was also used to specify the women's degree of satisfaction with care the day after surgery. The number of women who could be discharged from the outpatient unit and had a satisfaction score of ≥7 the day after surgery. Of the 150 women, 84% could be discharged after a mean observation period of 276 min (SD ± 80 min). The mean satisfaction score was 9.0, SD ± 1.4, and 92.6% of the women reported ≥7 points in the satisfaction score. No women with serious complications were sent home. Using a multivariable logistic regression model only pain at discharge was found as significant (p= 0.009) for admittance to hospital. Vaginal hysterectomy is a feasible outpatient procedure and the majority of women were satisfied with the care they received. © 2012 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2012 Nordic Federation of Societies of Obstetrics and Gynecology.

  8. The effects of vaginal prolapse surgery using synthetic mesh on vaginal wall sensibility, vaginal vasocongestion, and sexual function: a prospective single-center study

    NARCIS (Netherlands)

    Weber, Maaike A.; Lakeman, Marielle M. E.; Laan, Ellen; Roovers, Jan-Paul W. R.

    2014-01-01

    Vaginal mesh surgery in patients with pelvic organ prolapse (POP) has been associated with sexual dysfunction. Implantation of synthetic mesh might damage vaginal innervation and vascularization, which could cause sexual dysfunction. We aim to evaluate the effects of vaginal mesh surgery on vaginal

  9. Multiscalar production amplitudes beyond threshold

    CERN Document Server

    Argyres, E N; Kleiss, R H

    1993-01-01

    We present exact tree-order amplitudes for $H^* \\to n~H$, for final states containing one or two particles with non-zero three-momentum, for various interaction potentials. We show that there are potentials leading to tree amplitudes that satisfy unitarity, not only at threshold but also in the above kinematical configurations and probably beyond. As a by-product, we also calculate $2\\to n$ tree amplitudes at threshold and show that for the unbroken $\\phi^4$ theory they vanish for $n>4~$, for the Standard Model Higgs they vanish for $n\\ge 3~$ and for a model potential, respecting tree-order unitarity, for $n$ even and $n>4~$. Finally, we calculate the imaginary part of the one-loop $1\\to n$ amplitude in both symmetric and spontaneously broken $\\phi^4$ theory.

  10. Scattering amplitudes in gauge theories

    CERN Document Server

    Henn, Johannes M

    2014-01-01

    At the fundamental level, the interactions of elementary particles are described by quantum gauge field theory. The quantitative implications of these interactions are captured by scattering amplitudes, traditionally computed using Feynman diagrams. In the past decade tremendous progress has been made in our understanding of and computational abilities with regard to scattering amplitudes in gauge theories, going beyond the traditional textbook approach. These advances build upon on-shell methods that focus on the analytic structure of the amplitudes, as well as on their recently discovered hidden symmetries. In fact, when expressed in suitable variables the amplitudes are much simpler than anticipated and hidden patterns emerge.   These modern methods are of increasing importance in phenomenological applications arising from the need for high-precision predictions for the experiments carried out at the Large Hadron Collider, as well as in foundational mathematical physics studies on the S-matrix in quantum ...

  11. Amplitude damping of vortex modes

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2010-09-01

    Full Text Available An interferometer, mimicking an amplitude damping channel for vortex modes, is presented. Experimentally the action of the channel is in good agreement with that predicted theoretically. Since we can characterize the action of the channel on orbital...

  12. Vaginal mucosal flap as a sling preservation for the treatment of vaginal exposure of mesh.

    Science.gov (United States)

    Kim, Sea Young; Park, Jong Yeon; Kim, Han Kwon; Park, Chang Hoo; Kim, Sung Jin; Sung, Gi Teck; Park, Chang Myon

    2010-06-01

    Tension-free vaginal tape (TVT) procedures are used for the treatment of stress urinary incontinence in women. The procedures with synthetic materials can have a risk of vaginal erosion. We experienced transobturator suburethral sling (TOT) tape-induced vaginal erosion and report the efficacy of a vaginal mucosal covering technique. A total of 560 female patients diagnosed with stress urinary incontinence underwent TOT procedures at our hospital between January 2005 and August 2009. All patients succeeded in follow-ups, among which 8 patients (mean age: 50.5 years) presented with vaginal exposure of the mesh. A vaginal mucosal covering technique was performed under local anesthesia after administration of antibiotics and vaginal wound dressings for 3-4 days. Seven of the 8 patients complained of persistent vaginal discharge postoperatively. Two of the 8 patients complained of dyspareunia of their male partners. The one remaining patient was otherwise asymptomatic, but mesh erosion was discovered at the routine follow-up visit. Six of the 8 patients showed complete mucosal covering of the mesh after the operation (mean follow-up period: 16 moths). Vaginal mucosal erosion recurred in 2 patients, and the mesh was then partially removed. One patient had recurrent stress urinary incontinence. Vaginal mucosal covering as a sling preservation with continued patient continence may be a feasible and effective option for the treatment of vaginal exposure of mesh after TOT tape procedures.

  13. Motivic amplitudes and cluster coordinates

    International Nuclear Information System (INIS)

    Golden, J.K.; Goncharov, A.B.; Spradlin, M.; Vergu, C.; Volovich, A.

    2014-01-01

    In this paper we study motivic amplitudes — objects which contain all of the essential mathematical content of scattering amplitudes in planar SYM theory in a completely canonical way, free from the ambiguities inherent in any attempt to choose particular functional representatives. We find that the cluster structure on the kinematic configuration space Conf n (ℙ 3 ) underlies the structure of motivic amplitudes. Specifically, we compute explicitly the coproduct of the two-loop seven-particle MHV motivic amplitude A 7,2 M and find that like the previously known six-particle amplitude, it depends only on certain preferred coordinates known in the mathematics literature as cluster X-coordinates on Conf n (ℙ 3 ). We also find intriguing relations between motivic amplitudes and the geometry of generalized associahedrons, to which cluster coordinates have a natural combinatoric connection. For example, the obstruction to A 7,2 M being expressible in terms of classical polylogarithms is most naturally represented by certain quadrilateral faces of the appropriate associahedron. We also find and prove the first known functional equation for the trilogarithm in which all 40 arguments are cluster X-coordinates of a single algebra. In this respect it is similar to Abel’s 5-term dilogarithm identity

  14. Descriptiveness of vaginal secretions pH in the vaginal microbiota assessment in pregnant women

    Directory of Open Access Journals (Sweden)

    V. F. Nagornaya

    2016-07-01

    2 KU maternity hospital №7, Odessa           Summary 143 pregnant and 20 non-pregnant women have been examined. The objective: to determine the information content of  the vaginal fluid pH.  Methods used: Cytological, standard microbiological,  real time PCR, the measurement of vaginal fluid pH. Results: five types  of vaginal microbiota have been revealed, as well as a clear link of pH and the quantitative characteristic of microflora, high inverse correlation with  estradiol content was shown,  and correspondence to the number of gestation complications and the number of inflammatory diseases of the somatic plan was proved. The authors recommend to use pH of the vaginal fluid as an indicator of the state of vaginal biotope in the course of pregnancy.       Keywords: pH of the vaginal secretion, vaginal biotope pregnancy.

  15. Reoccurrence of retained placenta at vaginal delivery

    DEFF Research Database (Denmark)

    Nikolajsen, Sys; Løkkegaard, Ellen Christine Leth; Bergholt, Thomas

    2013-01-01

    To estimate the prevalence and validate the diagnosis of retained placenta in nulliparous women and the risk of reoccurrence at subsequent vaginal delivery.......To estimate the prevalence and validate the diagnosis of retained placenta in nulliparous women and the risk of reoccurrence at subsequent vaginal delivery....

  16. Use of vaginal hysterectomy in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Sidsel Lykke; Daugbjerg, Signe B; Gimbel, Helga

    2011-01-01

    To describe the use of vaginal, abdominal and laparoscopic hysterectomy in Denmark from 1999 to 2008, the influence of national guidelines and the patient and procedure-related characteristics associated with the choice of vaginal hysterectomy. Design. Nationwide register-based cohort study....

  17. VULVO-VAGINAL CANDIDIASIS ASSOCIATED WITH ACITRETIN

    NARCIS (Netherlands)

    STURKENBOOM, MCJM; MIDDELBEEK, A; VANDENBERG, LTWD; VANDENBERG, PB; STRICKER, BHC; WESSELING, H

    The aim of this study was to estimate the risk of vulvo-vaginal candidiasis among the users of acitretin. The incidence rate ratio of vulvo-vaginal candidiasis was estimated in a cohort of acitretin users by using prescription sequence analysis. Study subjects were 196 women between 15 and 45 years

  18. Short convalescence after vaginal prolapse surgery

    DEFF Research Database (Denmark)

    Ottesen, Marianne; Sørensen, Mette; Kehlet, Henrik

    2003-01-01

    OBJECTIVE: Retrospectively to describe the recommended convalescence according to patients who had undergone vaginal prolapse surgery in 1996-98, and prospectively to describe the need for and limiting factors for convalescence after vaginal prolapse surgery in 1999-2000 at a Danish University Ho...

  19. 21 CFR 884.3900 - Vaginal stent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to...

  20. Programmable femtosecond laser pulses in the ultraviolet

    International Nuclear Information System (INIS)

    Hacker, M.; Feurer, T.; Sauerbrey, R.; Lucza, T.; Szabo, G.

    2001-01-01

    Using a combination of a zero-dispersion compressor and spectrally compensated sum-frequency generation, we have produced amplitude-modulated femtosecond pulses in the UV at 200 nm. [copyright] 2001 Optical Society of America

  1. The role of interstitial brachytherapy in the treatment of vaginal and vulvar malignancies

    International Nuclear Information System (INIS)

    Seeger, A.R.; Windschall, A.; Lotter, M.; Sauer, R.; Strnad, V.; Mehlhorn, G.; Beckmann, M.W.

    2006-01-01

    Background: irradiation has established itself as a treatment for vulvar and vaginal malignancies. Due to the sensitive nature of the vulvar and vaginal tissues, interstitial brachytherapy (iBT) provides an effective, gentle and individualized therapy. Patients and Methods: patients with vulvar (nine of 22) and vaginal (13 of 22) malignancies were treated using interstitial pulsed-dose-rate brachytherapy (PDR-iBT). Twelve out of 22 patients were additionally treated using external-beam therapy to the pelvis and regional lymph nodes. The median total dose of PDR-iBT administered to patients with vulvar carcinoma was 55.0 Gy. The median total PDR dose administered to patients with vaginal malignancies amounted to 20.25 Gy. Results: the median follow-up time for patients with vulvar cancer was 19 months and for patients with vaginal malignancies 27 months. Acute mucositis or skin reactions during iBT were observed in 15 of 22 patients. Two of 22 patients showed delayed side effects. After 6 months, 77.8% of the patients with vulvar cancer (seven out of nine) and 100% of the patients with vaginal malignancies (13 out of 13) achieved complete local remission. One patient out of nine with vulvar carcinoma developed local recurrence, four out of nine regional recurrence, and two out of nine developed regional recurrence and had local tumor following therapy. In patients with malignancies of the vagina, no cases of local recurrence were observed, but distant metastases were found in five out of 13 patients. At the time of analysis, eleven out of 22 patients with vulvar or vaginal carcinoma were still alive. Conclusion: IBT achieved good local control without serious delayed side effects in both localizations. However, survival is limited by regional or distant metastases. (orig.)

  2. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections

    Directory of Open Access Journals (Sweden)

    Nenadić Dane

    2015-01-01

    Full Text Available Bacground/Aim. Vaginal and cervical swab culture is still very common procedure in our country’s everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM, vaginal pH and potassium hydroxide (KOH test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. Methods. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. Results. In 36 (6% patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11% women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19% women had BV, 19 (4% vaginitis, and 72 (14% candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21% had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30% women - in 83 (54% of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Conclusion. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal

  3. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections.

    Science.gov (United States)

    Nenadić, Dane; Pavlović, Miloš D

    2015-06-01

    Vaginal and cervical swab culture is still very common procedure in our country's everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM), vaginal pH and potassium hydroxide (KOH) test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV) and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN) was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. In 36 (6%) patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11%) women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19%) women had BV, 19 (4%) vaginitis, and 72 (14%) candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21%) had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30%) women--in 83 (54%) of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal infections.

  4. [Severe vaginal discharge following rectal surgery].

    Science.gov (United States)

    Burg, L C; Bremers, A J A; Heesakkers, J P F A; Kluivers, K B

    2018-01-01

    Almost 50% of women who have had rectal surgery subsequently develop vaginal discharge. Due to the recurrent and unexpected nature of this heavy discharge, they often experience it as very distressing. Many of these women undergo extensive diagnostic tests that are mainly focused on identifying fistula formation. If no fistula is found, in most cases no other cause for severe vaginal discharge can be demonstrated. In our practice, we saw three patients (49-, 54- and 74-years-old, respectively) with similar severe vaginal discharge after rectal surgery and in whom no explanation for the vaginal discharge could be found. For this reason we conducted a literature search into this condition. Anatomical changes appear to be responsible for heavy vaginal discharge following rectal surgery. Changes in pelvic floor muscles and compression of the distal part of the vagina may lead to pooling of fluid in the proximal part of the vagina, resulting in severe discharge. Symptomatic treatment may reduce the symptoms.

  5. Pulse Generator

    Science.gov (United States)

    Greer, Lawrence (Inventor)

    2017-01-01

    An apparatus and a computer-implemented method for generating pulses synchronized to a rising edge of a tachometer signal from rotating machinery are disclosed. For example, in one embodiment, a pulse state machine may be configured to generate a plurality of pulses, and a period state machine may be configured to determine a period for each of the plurality of pulses.

  6. Nd:YAG laser therapy for rectal and vaginal venous malformations.

    Science.gov (United States)

    Gurien, Lori A; Jackson, Richard J; Kiser, Michelle M; Richter, Gresham T

    2017-08-01

    Limited therapeutic options exist for rectal and vaginal venous malformations (VM). We describe our center's experience using Nd:YAG laser for targeted ablation of abnormal veins to treat mucosally involved pelvic VM. Records of patients undergoing non-contact Nd:YAG laser therapy of pelvic VM at a tertiary children's hospital were reviewed. Symptoms, operative findings and details, complications, and outcomes were evaluated. Nine patients (age 0-24) underwent Nd:YAG laser therapy of rectal and/or vaginal VM. Rectal bleeding was present in all patients and vaginal bleeding in all females (n = 5). 5/7 patients had extensive pelvic involvement on MRI. Typical settings were 30 (rectum) and 20-25 W (vagina), with 0.5-1.0 s pulse duration. Patients underwent the same-day discharge. Treatment intervals ranged from 14 to 180 (average = 56) weeks, with 6.1-year mean follow-up. Five patients experienced symptom relief with a single treatment. Serial treatments managed recurrent bleeding successfully in all patients, with complete resolution of vaginal lesions in 40% of cases. No complications occurred. Nd:YAG laser treatment of rectal and vaginal VM results in substantial improvement and symptom control, with low complication risk. Given the high morbidity of surgical resection, Nd:YAG laser treatment of pelvic VM should be considered as first line therapy.

  7. Large amplitude solitary waves in a multicomponent plasma with negative ions

    International Nuclear Information System (INIS)

    Nakamura, Y.; Tsukabayashi, I.; Ludwig, G.O.; Ferreira, J.L.

    1987-09-01

    When the concentration of negative ions is larger than a critical value, a small compressive pulse evolves into a subsonic wave train and a large pulse develops into a solitary wave. The threshold amplitude and velocity of the solitary waves are measured and compared with predictions using the pseudopotential method. (author) [pt

  8. Protection against rat vaginal candidiasis by adoptive transfer of vaginal B lymphocytes.

    Science.gov (United States)

    De Bernardis, Flavia; Santoni, Giorgio; Boccanera, Maria; Lucciarini, Roberta; Arancia, Silvia; Sandini, Silvia; Amantini, Consuelo; Cassone, Antonio

    2010-06-01

    Vulvovaginal candidiasis is a mucosal infection affecting many women, but the immune mechanisms operating against Candida albicans at the mucosal level remain unknown. A rat model was employed to further characterize the contribution of B and T cells to anti-Candida vaginal protection. Particularly, the protective role of vaginal B cells was studied by means of adoptive transfer of vaginal CD3(-) CD5(+) IgM(+) cells from Candida-immunized rats to naïve animals. This passive transfer of B cells resulted into a number of vaginal C. albicans CFU approximately 50% lower than their controls. Sorted CD3(-) CD5(+) IgM(+) vaginal B lymphocytes from Candida-infected rats proliferated in response to stimulation with an immunodominant mannoprotein (MP) antigen of the fungus. Importantly, anti-MP antibodies and antibody-secreting B cells were detected in the supernatant and cell cultures, respectively, of vaginal B lymphocytes from infected rats incubated in vitro with vaginal T cells and stimulated with MP. No such specific antibodies were found when using vaginal B cells from uninfected rats. Furthermore, inflammatory and anti-inflammatory cytokines, such as interleukin-2 (IL-2), IL-6 and IL-10, were found in the supernatant of vaginal B cells from infected rats. These data are evidence of a partial anti-Candida protective role of CD3(-) CD5(+) IgM(+) vaginal B lymphocytes in our experimental model.

  9. Nonsinglet pentagons and NMHV amplitudes

    Directory of Open Access Journals (Sweden)

    A.V. Belitsky

    2015-07-01

    Full Text Available Scattering amplitudes in maximally supersymmetric gauge theory receive a dual description in terms of the expectation value of the super Wilson loop stretched on a null polygonal contour. This makes the analysis amenable to nonperturbative techniques. Presently, we elaborate on a refined form of the operator product expansion in terms of pentagon transitions to compute twist-two contributions to NMHV amplitudes. To start with, we provide a novel derivation of scattering matrices starting from Baxter equations for flux-tube excitations propagating on magnon background. We propose bootstrap equations obeyed by pentagon form factors with nonsinglet quantum numbers with respect to the R-symmetry group and provide solutions to them to all orders in 't Hooft coupling. These are then successfully confronted against available perturbative calculations for NMHV amplitudes to four-loop order.

  10. Nonsinglet pentagons and NMHV amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Belitsky, A.V., E-mail: andrei.belitsky@asu.edu

    2015-07-15

    Scattering amplitudes in maximally supersymmetric gauge theory receive a dual description in terms of the expectation value of the super Wilson loop stretched on a null polygonal contour. This makes the analysis amenable to nonperturbative techniques. Presently, we elaborate on a refined form of the operator product expansion in terms of pentagon transitions to compute twist-two contributions to NMHV amplitudes. To start with, we provide a novel derivation of scattering matrices starting from Baxter equations for flux-tube excitations propagating on magnon background. We propose bootstrap equations obeyed by pentagon form factors with nonsinglet quantum numbers with respect to the R-symmetry group and provide solutions to them to all orders in 't Hooft coupling. These are then successfully confronted against available perturbative calculations for NMHV amplitudes to four-loop order.

  11. Cluster polylogarithms for scattering amplitudes

    International Nuclear Information System (INIS)

    Golden, John; Paulos, Miguel F; Spradlin, Marcus; Volovich, Anastasia

    2014-01-01

    Motivated by the cluster structure of two-loop scattering amplitudes in N=4 Yang-Mills theory we define cluster polylogarithm functions. We find that all such functions of weight four are made up of a single simple building block associated with the A 2 cluster algebra. Adding the requirement of locality on generalized Stasheff polytopes, we find that these A 2 building blocks arrange themselves to form a unique function associated with the A 3 cluster algebra. This A 3 function manifests all of the cluster algebraic structure of the two-loop n-particle MHV amplitudes for all n, and we use it to provide an explicit representation for the most complicated part of the n = 7 amplitude as an example. This article is part of a special issue of Journal of Physics A: Mathematical and Theoretical devoted to ‘Cluster algebras in mathematical physics’. (paper)

  12. Topological amplitudes in string theory

    International Nuclear Information System (INIS)

    Antoniadis, I.; Taylor, T.R.

    1993-07-01

    We show that certain type II string amplitudes at genus g are given by the topological partition F g discussed recently by Bershadsky, Cecotti, Ooguri and Vafa. These amplitudes give rise to a term in the four-dimensional effective action of the form Σ g F g W 2g , where W is the chiral superfield of N = 2 supergravitational multiplet. The holomorphic anomaly of F g is related to non-localities of the effective action due to the propagation of massless states. This result generalizes the holomorphic anomaly of the one loop case which is known to lead to non-harmonic gravitational couplings. (author). 22 refs, 2 figs

  13. A method to reduce the suppression of relevant pulses in pulse weight discriminators

    International Nuclear Information System (INIS)

    Schwartz, P.

    1975-01-01

    The pulse height analyzer is used, for instance, with proportional counters. Pulses are broken down into amplitude ranges in accordance with their maximum amplitudes. In pulse height analyzers with real time analog-digital conversion only one deadtime is needed for the respective range selected. For this purpose, all discriminator thresholds of the amplitude stores connected parallel are actuated as an input pulse arrives. The leading edges of the discriminator signals set the amplitude range flip-flop. Only the flip-flop circuit of the maximum amplitude range reached remains set whilst all the others are erased. The trailing edge of the discriminator signals actuates the evaluation of the information stored by the flip-flop circuit selected. It triggers a pulse extender and resets the flip-flop selected. Therefore, only the amplitude range selected needs a deadtime. The pulse extender in addition reduces the processing time of the analyzer by the output pulse length. The characteristic used for the trailing edge is the backward count of the real time analog-digital converter. (DG/RF) [de

  14. Endometrial safety of ultra-low-dose estradiol vaginal tablets

    DEFF Research Database (Denmark)

    Simon, James; Nachtigall, Lila; Ulrich, Lian G

    2010-01-01

    To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17ß-estradiol vaginal tablets in postmenopausal women with vaginal atrophy.......To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17ß-estradiol vaginal tablets in postmenopausal women with vaginal atrophy....

  15. Endometrial safety of ultra-low-dose estradiol vaginal tablets

    DEFF Research Database (Denmark)

    Simon, James; Nachtigall, Lila; Ulrich, Lian G

    2010-01-01

    To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17β-estradiol vaginal tablets in postmenopausal women with vaginal atrophy.......To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17β-estradiol vaginal tablets in postmenopausal women with vaginal atrophy....

  16. High current transistor pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.; Cassel, R.

    1991-05-01

    A solid state pulse generator capable of delivering high current trapezoidally shaped pulses into an inductive load has been developed at SLAC. Energy stored in the capacitor bank of the pulse generator is switched to the load through a pair of Darlington transistors. A combination of diodes and Darlington transistors is used to obtain trapezoidal or triangular shaped current pulses into an inductive load and to recover the remaining energy in the same capacitor bank without reversing capacitor voltage. The transistors work in the switch mode, and the power losses are low. The rack mounted pulse generators presently used at SLAC contain a 660 microfarad storage capacitor bank and can deliver 400 amps at 800 volts into inductive loads up to 3 mH. The pulse generators are used in several different power systems, including pulse to pulse bipolar power supplies and in application with current pulses distributed into different inductive loads. The current amplitude and discharge time are controlled by the central computer system through a specially developed multichannel controller. Several years of operation with the pulse generators have proven their consistent performance and reliability. 8 figs

  17. The Vaginal Microbiota and Urinary Tract Infection.

    Science.gov (United States)

    Stapleton, Ann E

    2016-12-01

    The vagina is a key anatomical site in the pathogenesis of urinary tract infection (UTI) in women, serving as a potential reservoir for infecting bacteria and a site at which interventions may decrease the risk of UTI. The vaginal microbiota is a dynamic and often critical factor in this pathogenic interplay, because changes in the characteristics of the vaginal microbiota resulting in the loss of normally protective Lactobacillus spp. increase the risk of UTI. These alterations may result from the influence of estrogen deficiency, antimicrobial therapy, contraceptives, or other causes. Interventions to reduce adverse effects on the vaginal microbiota and/or to restore protective lactobacilli may reduce the risks of UTI.

  18. Proinflammatory Cytokines as Regulators of Vaginal Microbiota.

    Science.gov (United States)

    Kremleva, E A; Sgibnev, A V

    2016-11-01

    It was shown that IL-1β, IL-8, and IL-6 in concentrations similar to those in the vagina of healthy women stimulated the growth of normal microflora (Lactobacillus spp.) and suppressed the growth and biofilm production by S. aureus and E. coli. On the contrary, these cytokines in higher concentrations typical of vaginal dysbiosis suppressed normal microflora and stimulated the growth of opportunistic microorganisms. TGF-β1 in both doses produced a stimulating effects on study vaginal microsymbionts. It is hypothesized that pro-inflammatory cytokines serve as the molecules of interspecies communication coordinating the interactions of all components of the vaginal symbiotic system.

  19. Vaginal rings for delivery of HIV microbicides.

    Science.gov (United States)

    Malcolm, R Karl; Fetherston, Susan M; McCoy, Clare F; Boyd, Peter; Major, Ian

    2012-01-01

    Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing.

  20. Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.

    Science.gov (United States)

    Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram

    2016-11-01

    Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.

  1. N-loop string amplitude

    International Nuclear Information System (INIS)

    Mandelstam, S.

    1986-06-01

    Work on the derivation of an explicit perturbation series for string and superstring amplitudes is reviewed. The light-cone approach is emphasized, but some work on the Polyakov approach is also mentioned, and the two methods are compared. The calculation of the measure factor is outlined in the interacting-string picture

  2. Scattering Amplitudes from Intersection Theory.

    Science.gov (United States)

    Mizera, Sebastian

    2018-04-06

    We use Picard-Lefschetz theory to prove a new formula for intersection numbers of twisted cocycles associated with a given arrangement of hyperplanes. In a special case when this arrangement produces the moduli space of punctured Riemann spheres, intersection numbers become tree-level scattering amplitudes of quantum field theories in the Cachazo-He-Yuan formulation.

  3. Positivity of spin foam amplitudes

    International Nuclear Information System (INIS)

    Baez, John C; Christensen, J Daniel

    2002-01-01

    The amplitude for a spin foam in the Barrett-Crane model of Riemannian quantum gravity is given as a product over its vertices, edges and faces, with one factor of the Riemannian 10j symbols appearing for each vertex, and simpler factors for the edges and faces. We prove that these amplitudes are always nonnegative for closed spin foams. As a corollary, all open spin foams going between a fixed pair of spin networks have real amplitudes of the same sign. This means one can use the Metropolis algorithm to compute expectation values of observables in the Riemannian Barrett-Crane model, as in statistical mechanics, even though this theory is based on a real-time (e iS ) rather than imaginary-time e -S path integral. Our proof uses the fact that when the Riemannian 10j symbols are nonzero, their sign is positive or negative depending on whether the sum of the ten spins is an integer or half-integer. For the product of 10j symbols appearing in the amplitude for a closed spin foam, these signs cancel. We conclude with some numerical evidence suggesting that the Lorentzian 10j symbols are always nonnegative, which would imply similar results for the Lorentzian Barrett-Crane model

  4. Employing Helicity Amplitudes for Resummation

    NARCIS (Netherlands)

    Moult, I.; Stewart, I.W.; Tackmann, F.J.; Waalewijn, W.J.

    2015-01-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are

  5. Scattering amplitudes in gauge theories

    Energy Technology Data Exchange (ETDEWEB)

    Henn, Johannes M. [Institute for Advanced Study, Princeton, NJ (United States). School of Natural Sciences; Plefka, Jan C. [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik

    2014-03-01

    First monographical text on this fundamental topic. Course-tested, pedagogical and self-contained exposition. Includes exercises and solutions. At the fundamental level, the interactions of elementary particles are described by quantum gauge field theory. The quantitative implications of these interactions are captured by scattering amplitudes, traditionally computed using Feynman diagrams. In the past decade tremendous progress has been made in our understanding of and computational abilities with regard to scattering amplitudes in gauge theories, going beyond the traditional textbook approach. These advances build upon on-shell methods that focus on the analytic structure of the amplitudes, as well as on their recently discovered hidden symmetries. In fact, when expressed in suitable variables the amplitudes are much simpler than anticipated and hidden patterns emerge. These modern methods are of increasing importance in phenomenological applications arising from the need for high-precision predictions for the experiments carried out at the Large Hadron Collider, as well as in foundational mathematical physics studies on the S-matrix in quantum field theory. Bridging the gap between introductory courses on quantum field theory and state-of-the-art research, these concise yet self-contained and course-tested lecture notes are well-suited for a one-semester graduate level course or as a self-study guide for anyone interested in fundamental aspects of quantum field theory and its applications. The numerous exercises and solutions included will help readers to embrace and apply the material presented in the main text.

  6. Scattering amplitudes in gauge theories

    International Nuclear Information System (INIS)

    Henn, Johannes M.; Plefka, Jan C.

    2014-01-01

    First monographical text on this fundamental topic. Course-tested, pedagogical and self-contained exposition. Includes exercises and solutions. At the fundamental level, the interactions of elementary particles are described by quantum gauge field theory. The quantitative implications of these interactions are captured by scattering amplitudes, traditionally computed using Feynman diagrams. In the past decade tremendous progress has been made in our understanding of and computational abilities with regard to scattering amplitudes in gauge theories, going beyond the traditional textbook approach. These advances build upon on-shell methods that focus on the analytic structure of the amplitudes, as well as on their recently discovered hidden symmetries. In fact, when expressed in suitable variables the amplitudes are much simpler than anticipated and hidden patterns emerge. These modern methods are of increasing importance in phenomenological applications arising from the need for high-precision predictions for the experiments carried out at the Large Hadron Collider, as well as in foundational mathematical physics studies on the S-matrix in quantum field theory. Bridging the gap between introductory courses on quantum field theory and state-of-the-art research, these concise yet self-contained and course-tested lecture notes are well-suited for a one-semester graduate level course or as a self-study guide for anyone interested in fundamental aspects of quantum field theory and its applications. The numerous exercises and solutions included will help readers to embrace and apply the material presented in the main text.

  7. Employing helicity amplitudes for resummation

    International Nuclear Information System (INIS)

    Moult, Ian; Stewart, Iain W.; Tackmann, Frank J.; Waalewijn, Wouter J.; Amsterdam Univ.

    2015-08-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are directly given in terms of color-ordered helicity amplitudes. Using this basis allows one to seamlessly combine fixed-order helicity amplitudes at any order they are known with a resummation of higher-order logarithmic corrections. In particular, the virtual loop amplitudes can be employed in factorization theorems to make predictions for exclusive jet cross sections without the use of numerical subtraction schemes to handle real-virtual infrared cancellations. We also discuss matching onto SCET in renormalization schemes with helicities in 4- and d-dimensions. To demonstrate that our helicity operator basis is easy to use, we provide an explicit construction of the operator basis, as well as results for the hard matching coefficients, for pp → H+0,1,2 jets, pp → W/Z/γ+0,1,2 jets, and pp → 2,3 jets. These operator bases are completely crossing symmetric, so the results can easily be applied to processes with e + e - and e - p collisions.

  8. Discontinuity formulas for multiparticle amplitudes

    International Nuclear Information System (INIS)

    Stapp, H.P.

    1976-03-01

    It is shown how discontinuity formulas for multiparticle scattering amplitudes are derived from unitarity and analyticity. The assumed analyticity property is the normal analytic structure, which was shown to be equivalent to the space-time macrocausality condition. The discontinuity formulas to be derived are the basis of multi-particle fixed-t dispersion relations

  9. Distribution amplitudes of vector mesons

    Energy Technology Data Exchange (ETDEWEB)

    Braun, V.M. [Regensburg Univ. (Germany). Inst. fuer Theoretische Physik; Broemmel, D. [Deutsches Elektronen-Synchrotron, Hamburg (Germany); Goeckeler, M. [Regensburg Univ. (DE). Inst. fuer Theoretische Physik] (and others)

    2007-11-15

    Results are presented for the lowest moment of the distribution amplitude for the K{sup *} vector meson. Both longitudinal and transverse moments are investigated. We use two flavours of O(a) improved Wilson fermions, together with a non-perturbative renormalisation of the matrix element. (orig.)

  10. Directed shift of vaginal microbiota induced by vaginal application of sucrose gel in rhesus macaques

    OpenAIRE

    Hu, Kai-tao; Zheng, Jin-xin; Yu, Zhi-jian; Chen, Zhong; Cheng, Hang; Pan, Wei-guang; Yang, Wei-zhi; Wang, Hong-yan; Deng, Qi-wen; Zeng, Zhong-ming

    2015-01-01

    Objectives: Sucrose gel was used to treat bacterial vaginosis in a phase III clinical trial. However, the changes of vaginal flora after treatment were only examined by Nugent score in that clinical trial, While the vaginal microbiota of rhesus macaques is characterized by anaerobic, Gram-negative bacteria, few lactobacilli, and pH levels above 4.6, similar to the microbiota of patients with bacterial vaginosis. This study is aimed to investigate the change of the vaginal microbiota of rehsus...

  11. Vaginal Calculus in a Woman With Mixed Urinary Incontinence and Vaginal Mesh Exposure.

    Science.gov (United States)

    Winkelman, William D; Rabban, Joseph T; Korn, Abner P

    2016-01-01

    Vaginal calculi are extremely rare and are most commonly encountered in the setting of an urethrovaginal or vesicovaginal fistula. We present a case of a 72-year-old woman with mixed urinary incontinence and vaginal mesh exposure incidentally found to have a large vaginal calculus. We removed the calculus surgically and analyzed the components. Results demonstrated the presence of ammonium-magnesium phosphate hexahydrate and carbonate apatite.

  12. Controllable Pulse Frequency and Width System for Pulsing and Modulating Fast-Neutron Core Assemblies; Systeme a Frequence et Largeur d'Impulsions Ajustables Permettant la Pulsation et la Modulation de Milieux Multipliants Sous-Critiques a Neutrons Rapides; Sistema reguliruemykh chastoty i shiriny impul'sa, dayushaya impul's i modulyatsiyu razmnozhayushchikh sred na bystrykh nejtronakh; Sistema de Frecuencia y Amplitud de Impulso Ajustables, para Pulsar y Modular

    Energy Technology Data Exchange (ETDEWEB)

    Duquesne, M.; Lyon, F.; Schmitt, A. [Association Euratom-CEA-SECNR (France); Nucleaires de Cadarache, Centre d' Etudes [France; Gerbier, R. [Laboratoire des Accelerateurs - CEN de Grenoble (France); Nucleaires de Cadarache, Centre d' Etudes [France

    1965-10-15

    The authors describe a system for producing neutron bursts of independently controllable width and frequency. The rise and quenching times of these bursts are of the order of a few nanoseconds. The system is applied to high-frequency pulsed and modulated experiments. Rapidly quenched neutron bursts are produced by deflection of a pure deuteron beam which has previously been accelerated and sorted. Ions other than atomic deuterons are removed after acceleration in a 10 Degree-Sign magnetic sorting field. Consideration is also being given to a pre-acceleration sorting system offering the advantage of reduced bulk. The deuteron beam passes through the space between two plates where there is normally an electrostatic field which deflects the beam onto the surfaces of a diaphragm. Application of a very high potential pulse to the first plate cancels the field and thus brings the beam rapidly onto the neutron-producing target (beginning of the burst). The second plate then receives a pulse of the same type which restores the field and removes the beam from the target (end of the burst). The pulse rise time is of the order of 10 ns; disappearance from the target is faster. The duration of the burst can be controlled as required within reasonable limits by suitably increasing the interval between the two pulses. In some cases ion transit time in the plates is not negligible in relation to the duration of the step applied to them. In such cases, one of the plates is replaced by a travelling wave line to which the two pulses are applied successively. The potential pulse thus accompanies the deuteron cluster producing the burst. The burst times can thus be reduced below 4 ns. The first stages of the voltage step generators are transistorized. The output tubes are sealed-disc valves providing a 1500-V step in a few nanoseconds. A 50-MHz double tetrode is employed for pulses for the delay line. A detection system comprises a scintillator-photomultiplier device incorporating a

  13. Custom pulse generator for RPC testing

    International Nuclear Information System (INIS)

    Gil, A.; Castro, E.; Diaz, J.; Fonte, P.; Garzon, J.A.; Montes, N.; Zapata, M.

    2009-01-01

    We present a pulse generator able to generate pulses statistically similar to the ones produced by RPC cells. The device generates up to four arrays of fast and narrow random-like pulses. Polarity, maximum amplitudes, widths and pulse rate in each channel may be modified independently in order to simulate different RPC setups and environments. This portable and cost-effective pulse generator is a versatile instrument for testing FE-Electronics and different real detector features related with the signal propagation inside the detector. It has been developed in the framework of the ESTRELA project of the HADES experiment at GSI.

  14. Relationship between lactobacilli and opportunistic bacterial pathogens associated with vaginitis

    OpenAIRE

    Razzak, Mohammad Sabri A.; Al-Charrakh, Alaa H.; AL-Greitty, Bara Hamid

    2011-01-01

    Background: Vaginitis, is an infectious inflammation of the vaginal mucosa, which sometimes involves the vulva. The balance of the vaginal flora is maintained by the Lactobacilli and its protective and probiotic role in treating and preventing vaginal infection by producing antagonizing compounds which are regarded as safe for humans. Aim: The aim of this study was to evaluate the protective role of Lactobacilli against common bacterial opportunistic pathogens in vaginitis and study the effec...

  15. Prevalence of vaginal candidiasis among pregnant women with abnormal vaginal discharge in Maiduguri.

    Science.gov (United States)

    Ibrahim, S M; Bukar, M; Mohammed, Y; Mohammed, B; Yahaya, M; Audu, B M; Ibrahim, H M; Ibrahim, H A

    2013-01-01

    Pregnancy represents a risk factor in the occurrence of vaginal candidiasis. To determine the prevalence and clinical features associated with abnormal vaginal discharge and C. albicans infection in pregnant women. High vaginal swab samples and data on epidemiological characteristics were collected from 400 pregnant women with complaints of abnormal vaginal discharge at booking clinic of University of Maiduguri Teaching Hospital. The data was analysed using SPSS 16.0 statistical software. The prevalence of abnormal vaginal discharge in pregnancy was 31.5%. The frequency of abnormal vaginal discharge was 183 (45.8%) among those aged 20-24 years, 291 (72.8%) in multipara, 223 (55.8%) in those with Primary education and 293 (73.2%) in unemployed. Vulval pruritus 300 (75.0%) was significantly related to abnormal vaginal discharge (P candidiasis were 151 (50.3%), 14 (56.0%) and 75 (75.0%) respectively (P vaginal discharge in pregnancy was high in this study and C. albicans was the commonest cause. It is recommended that a pregnant woman complaining of abnormal vaginal discharge be assessed and Laboratory diagnosis done in order to give appropriate treatment.

  16. Quantitative studies on the vaginal flora of asymptomatic women and patients with vaginitis and vaginosis.

    Science.gov (United States)

    Hammann, R; Kronibus, A; Lang, N; Werner, H

    1987-07-01

    Vaginal washings of 22 patients with vaginitis, 11 with vaginosis, and 12 healthy subjects were investigated quantitatively and qualitatively for aerobic and anaerobic bacteria and yeasts. Gardnerella vaginalis was recovered from 9 of the vaginitis patients, 7 of the vaginosis patients, and 4 of the asymptomatic subjects. Obligate anaerobes were found in 11 of the vaginitis patients, 4 of the vaginosis patients, and none of the control subjects. Bacteroides bivius was the anaerobe most frequently isolated from symptomatic subjects. Anaerobic vibrios were recovered twice from symptomatic subjects. The counts for Gardnerella vaginalis and anaerobes when present were generally very high. The most frequent aerobes were beta-hemolytic streptococci (group B) and staphylococci.

  17. Evaluation of vaginal flora and susceptibility test of microorganisms in reproductive-age women with or without vaginitis in primary care settings

    OpenAIRE

    Alim, Ahmet; Çetin, Ali; Yıldız, Çağlar

    2009-01-01

    AbstractAims. The treatment modalities of patients with vaginal discharge are generally related to their symptoms. The aim of this study was to evaluate vaginal flora and antibiogram analysis in reproductive-age women with or without vaginitis in primary care settings. Methods. Vaginal swabs were taken from 311 women who have vaginitis, and tested for the causative agents of vaginal discharge. The control group was 89 healthy women without vaginal discharge. Vaginal swaps were used in a comme...

  18. Ultrarelativistic electromagnetic pulses in plasmas

    Science.gov (United States)

    Ashour-Abdalla, M.; Leboeuf, J. N.; Tajima, T.; Dawson, J. M.; Kennel, C. F.

    1981-01-01

    The physical processes of a linearly polarized electromagnetic pulse of highly relativistic amplitude in an underdense plasma accelerating particles to very high energies are studied through computer simulation. An electron-positron plasma is considered first. The maximum momenta achieved scale as the square of the wave amplitude. This acceleration stops when the bulk of the wave energy is converted to particle energy. The pulse leaves behind as a wake a vacuum region whose length scales as the amplitude of the wave. The results can be explained in terms of a snow plow or piston-like action of the radiation on the plasma. When a mass ratio other than unity is chosen and electrostatic effects begin to play a role, first the ion energy increases faster than the electron energy and then the electron energy catches up later, eventually reaching the same value.

  19. Optical clearing of vaginal tissues in cadavers

    Science.gov (United States)

    Chang, Chun-Hung; Hardy, Luke A.; Peters, Michael G.; Bastawros, Dina A.; Myers, Erinn M.; Kennelly, Michael J.; Fried, Nathaniel M.

    2018-02-01

    A nonsurgical laser procedure is being developed for treatment of female stress urinary incontinence (SUI). Previous studies in porcine vaginal tissues, ex vivo, as well as computer simulations, showed the feasibility of using near-infrared laser energy delivered through a transvaginal contact cooling probe to thermally remodel endopelvic fascia, while preserving the vaginal wall from thermal damage. This study explores optical properties of vaginal tissue in cadavers as an intermediate step towards future pre-clinical and clinical studies. Optical clearing of tissue using glycerol resulted in a 15-17% increase in optical transmission after 11 min at room temperature (and a calculated 32.5% increase at body temperature). Subsurface thermal lesions were created using power of 4.6 - 6.4 W, 5.2-mm spot, and 30 s irradiation time, resulting in partial preservation of vaginal wall to 0.8 - 1.1 mm depth.

  20. Vaginal itching and discharge - Adult and adolescent

    Science.gov (United States)

    ... 003158.htm Vaginal itching and discharge - adult and adolescent To use the sharing features on this page, ... fabric softeners, feminine sprays, ointments, creams, douches, and contraceptive foams or jellies or creams. This may irritate ...

  1. Vaginal neurofibroma in a hysterectomized poodle dog.

    Science.gov (United States)

    Sontas, B H; Altun, E D; Güvenc, K; Arun, S S; Ekici, H

    2010-12-01

    A 15-year-old, spayed, female poodle dog was presented for evaluation of a mass of tissue prolapsed from the vulva. The dog had been hysterectomized when it was 5 years old. A vaginal mass had been removed approximately 10 months before presentation. Haematological and serum biochemistry analyses demonstrated mild leucocytosis and glycaemia. A vaginal smear was predominantly made up of parabasal cells and intermediate cells with no neoplastic cells. Thoracal and abdominal radiographic findings were unremarkable. The ovaries could not be identified using abdominal ultrasonography. A midline exploratory laparotomy identified both ovaries that were surgically excised. The vaginal mass was also removed following an episiotomy procedure. Histopathological examination of the mass demonstrated that it was a neurofibroma. Both ovaries had cystic changes. Four months after the surgery, the owner reported that the dog was clinically normal. To the authors’ knowledge, this is the first reported case of a vaginal neurofibroma after an incomplete ovariohysterectomy in the dog.

  2. How Do Health Care Providers Diagnose Vaginitis?

    Science.gov (United States)

    ... used to diagnose vaginitis. 1 Centers for Disease Control and Prevention. (2010). Self-study STD ... Halvorson New Chief of Gynecologic Health and Disease Branch Division of Epidemiology, Statistics, ...

  3. What Are the Symptoms of Vaginitis?

    Science.gov (United States)

    ... Many women have no symptoms. Centers for Disease Control and Prevention. (2010). Self-study STD module—vaginitis . Retrieved ... New Chief of Gynecologic Health and Disease Branch Division of Epidemiology, Statistics, ...

  4. Short convalescence after vaginal prolapse surgery

    DEFF Research Database (Denmark)

    Ottesen, Marianne; Sørensen, Mette; Kehlet, Henrik

    2003-01-01

    OBJECTIVE: Retrospectively to describe the recommended convalescence according to patients who had undergone vaginal prolapse surgery in 1996-98, and prospectively to describe the need for and limiting factors for convalescence after vaginal prolapse surgery in 1999-2000 at a Danish University...... Hospital. METHODS: The retrospective study included a validated, postal, questionnaire and review of patient files. In the prospective study, we followed consecutive women after vaginal surgery in a fast-track setting using a multimodal rehabilitation model with well-defined recommendations...... exceeding 10 kg. Limiting factors were fatigue and pain. The 1-year subjective recurrence rate was 17%. CONCLUSION: Traditionally, recommended convalescence has been median 6 weeks after vaginal prolapse surgery. Convalescence has been shortened to 1-3 weeks with a multimodal rehabilitation model...

  5. Fast differential pulse discriminator-counter

    International Nuclear Information System (INIS)

    Shelevoj, K.D.

    1985-01-01

    The flowsheet of a differential pulse discriminator counter is described; the result of discrimination here is independent from the shape of the input pulse. Rate of the analysis of input pulses with minimum amplitude up to 0.3 mV coming out from the photomultiplier makes up 220 MHz. The flowsheet of the discriminator used in the system of photon counting for atmosphere probing is presented

  6. Vaginal microbiota and viral sexually transmitted diseases.

    Science.gov (United States)

    Nardis, C; Mosca, L; Mastromarino, P

    2013-01-01

    Healthy vaginal microbiota is an important biological barrier to pathogenic microorganisms. When this predominantly Lactobacillus community is disrupted, decreased in abundance and replaced by different anaerobes, bacterial vaginosis (BV) may occur. BV is associated with prevalence and incidence of several sexually transmitted infections. This review provides background on BV, discusses the epidemiologic data to support a role of altered vaginal microbiota for acquisition of sexually transmitted diseases and analyzes mechanisms by which lactobacilli could counteract sexually transmitted viral infections.

  7. The vaginal microbiome: rethinking health and diseases

    Science.gov (United States)

    Ma, Bing; Forney, Larry J.; Ravel, Jacques

    2013-01-01

    Vaginal microbiota form a mutually beneficial relationship with their host and have major impact on health and disease. In recent years our understanding of vaginal bacterial community composition and structure has significantly broadened as a result of investigators using cultivation-independent methods based on the analysis of 16S ribosomal RNA (rRNA) gene sequences. In asymptomatic, otherwise healthy women, several kinds of vaginal microbiota exist, the majority often dominated by species of Lactobacillus, while others comprise a diverse array of anaerobic microorganisms. Bacterial vaginosis is the most common vaginal conditions and is vaguely characterized as the disruption of the equilibrium of the ‘normal’ vaginal microbiots. A better understanding of ‘normal’ and ‘healthy’ vaginal ecosystems that is based on its ‘true’ function and not simply on its composition would help better define health and further improve disease diagnostics as well as the development of more personalized regimens to promote health and treat diseases. PMID:22746335

  8. Vaginal microbial flora and outcome of pregnancy.

    Science.gov (United States)

    Donati, Laura; Di Vico, Augusto; Nucci, Marta; Quagliozzi, Lorena; Spagnuolo, Terryann; Labianca, Antonietta; Bracaglia, Marina; Ianniello, Francesca; Caruso, Alessandro; Paradisi, Giancarlo

    2010-04-01

    The vaginal microflora of a healthy asymptomatic woman consists of a wide variety of anaerobic and aerobic bacterial genera and species dominated by the facultative, microaerophilic, anaerobic genus Lactobacillus. The activity of Lactobacillus is essential to protect women from genital infections and to maintain the natural healthy balance of the vaginal flora. Increasing evidence associates abnormalities in vaginal flora during pregnancy with preterm labor and delivery with potential neonatal sequelae due to prematurity and poor perinatal outcome. Although this phenomenon is relatively common, even in populations of women at low risk for adverse events, the pathogenetic mechanism that leads to complications in pregnancy is still poorly understood. This review summarizes the current knowledge and uncertainties in defining alterations of vaginal flora in non-pregnant adult women and during pregnancy, and, in particular, investigates the issue of bacterial vaginosis and aerobic vaginitis. This could help specialists to identify women amenable to treatment during pregnancy leading to the possibility to reduce the preterm birth rate, preterm premature rupture of membranes, chorioamnionitis, neonatal, puerperal and maternal-fetal infectious diseases. Vaginal ecosystem study with the detection of pathogens is a key instrument in the prevention of preterm delivery, pPROM, chorioamnionitis, neonatal, puerperal and maternal-fetal infections.

  9. Scruncher phase and amplitude control

    International Nuclear Information System (INIS)

    DeHaven, R.A.; Morris, C.L.; Johnson, R.; Davis, J.; O'Donnell, J.M.

    1992-01-01

    The analog controller for phase and amplitude control of a 402.5 MHz super conducting cavity is described in this paper. The cavity is a single cell with niobium explosively bonded to a copper cavity. It is used as an energy compressor for pions at the Clinton P. Anderson Meson Physics Facility (LAMPF). The controller maintains cavity frequency to within 4 degrees in phase of the LAMPF beam frequency. Field amplitude is maintained to within 2 percent. This control is accomplished at critical coupling (Q load of 1 x 10 9 ) with the use of only a 30 watt rf amplifier for accelerating fields of 6 MV/m. The design includes the use of piezoelectric crystals for fast resonance control. Three types of control, self excited, VCO, and a reference frequency driven, were tried on this cavity and we present a comparison of their performance. (Author) 4 figs., ref

  10. SCRUNCHER phase and amplitude control

    International Nuclear Information System (INIS)

    DeHaven, R.A.; Morris, C.L.; Johnson, R.; Davis, J.; O'Donnell, J.M.

    1992-01-01

    The analog controller for phase and amplitude control of a 402.5 MHz super conducting cavity is described in this paper. The cavity is a single cell with niobium explosively bonded to a copper cavity. It is used as an energy compressor for pions at the Clinton P. Anderson Meson Physics Facility (LAMPF). The controller maintains cavity frequency to within 4 degrees in phase of the LAMPF beam frequency. Field amplitude is maintained to within 2 percent. This control is accomplished at critical coupling (Q loaded of 1 x 10 9 ) with the use of only a 30 watt rf amplifier for accelerating fields of 6 MV/m. The design includes the use of piezoelectric crystals for fast resonance control. Three types of control, self excited VCO, and a reference frequency driven, were tried on this cavity and we present a comparison of their performance

  11. Periodic instantons and scattering amplitudes

    International Nuclear Information System (INIS)

    Khlebnikov, S.Yu.; Rubakov, V.A.; Tinyakov, P.G.

    1991-04-01

    We discuss the role of periodic euclidean solutions with two turning points and zero winding number (periodic instantons) in instanton induced processes below the sphaleron energy E sph . We find that the periodic instantons describe certain multiparticle scattering events leading to the transitions between topologically distinct vacua. Both the semiclassical amplitudes and inital and final states of these transitions are determined by the periodic instantons. Furthermore, the corresponding probabilities are maximal among all states of given energy. We show that at E ≤ E sph , the periodic instantons can be approximated by infinite chains of ordinary instantons and anti-instantons, and they naturally emerge as deformations of the zero energy instanton. In the framework of 2d abelian Higgs model and 4d electroweak theory we show, however, that there is not obvious relation between periodic instantons and two-particle scattering amplitudes. (orig.)

  12. Successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia: A rare case report.

    Science.gov (United States)

    Liu, Yu; Wang, Yi-Feng

    2017-07-01

    We report a case of successful vaginal delivery after vaginal reconstruction with labium minus flaps in a 23-year-old patient with congenital vaginal atresia. The patient primarily presented with amenorrhea and cyclic abdominal pain; transabdominal ultrasonography revealed an enlarged uterus due to hematometra and absence of the lower segment of the vagina. Eight years ago, she had undergone an unsuccessful attempt at canalization at a local hospital. Upon referral to our hospital, she underwent vaginal reconstruction with labium minus flaps. Four months after this procedure, she became pregnant and, subsequently, successfully and safely vaginally delivered a healthy female baby weighing 3250 g at 38 +1 weeks' gestation. The delivery did not involve perineal laceration by lateral episiotomy. To the best of our knowledge, this is the first reported case of successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia. © 2017 Japan Society of Obstetrics and Gynecology.

  13. The comparison of hyaluronic acid vaginal tablets with estradiol vaginal tablets in the treatment of atrophic vaginitis: a randomized controlled trial.

    Science.gov (United States)

    Ekin, Murat; Yaşar, Levent; Savan, Kadir; Temur, Muzaffer; Uhri, Mehmet; Gencer, Işıl; Kıvanç, Esra

    2011-03-01

    To compare the effectiveness of the vaginal tablets of hyaluronic acid and estrodiol for the treatment of atrophic vaginitis. Forty-two postmenopausal women with symptoms of atrophic vaginitis were randomized to take vaginal tablets of 25 μg estradiol (n = 21) (group I) or 5 mg hyaluronic acid sodium salt (n = 21) (group II) for 8 weeks. The symptoms of atrophic vaginitis were evaluated by a self-assessed 4-point scale of composite score and the degree of epithelial atrophy was determined as, none, mild, moderate and severe. Vaginal pH and maturation index were measured and compared in both the groups. The symptoms were relieved significantly in both the groups (P Hyaluronic acid vaginal tablets can be used in patients with atrophic vaginitis who do not want to or can not take local estrogen treatment.

  14. Determination of the scattering amplitude

    International Nuclear Information System (INIS)

    Gangal, A.D.; Kupsch, J.

    1984-01-01

    The problem to determine the elastic scattering amplitude from the differential cross-section by the unitarity equation is reexamined. We prove that the solution is unique and can be determined by a convergent iteration if the parameter lambda=sin μ of Newton and Martin is bounded by lambda 2 approx.=0.86. The method is based on a fixed point theorem for holomorphic mappings in a complex Banach space. (orig.)

  15. Semiclassical approach to fidelity amplitude

    International Nuclear Information System (INIS)

    García-Mata, Ignacio; Vallejos, Raúl O; Wisniacki, Diego A

    2011-01-01

    The fidelity amplitude (FA) is a quantity of paramount importance in echo-type experiments. We use semiclassical theory to study the average FA for quantum chaotic systems under external perturbation. We explain analytically two extreme cases: the random dynamics limit - attained approximately by strongly chaotic systems - and the random perturbation limit, which shows a Lyapunov decay. Numerical simulations help us to bridge the gap between both the extreme cases. (paper)

  16. Synchronization circuit for shaping electron beam picosecond pulses

    International Nuclear Information System (INIS)

    Pavlov, Yu.S.; Solov'ev, N.G.; Tomnikov, A.P.

    1985-01-01

    A fast response circuit of modulator trigger pulse synchronization of a deflector of the electron linear accelerator at 13 MeV with the given phase of HF-voltage is described. The circuit is constructed using K500 and K100 integrated emitter-coupled logics circuits. Main parameters of a synchropulse are duration of 20-50 ns, pulse rise time of 1-5 ns, pulse amplitude >=10 V, delay instability of a trigger pulse <=+-0.05 ns. A radiopulse with 3 μs duration, 5 V amplitude and 400 Hz frequency enters the circuit input. The circuit can operate at both pulsed operation and continuous modes

  17. Nonspecific aerobic vaginitis and pregnancy.

    Science.gov (United States)

    Curzik, D; Drazancić, A; Hrgović, Z

    2001-01-01

    During the period 1996-1998, cervical swabs of 50 pregnant women with subacute amniotic infection syndrome (AIS) and the semen of their consorts were bacteriologically analyzed. In the control group were 50 healthy pregnant women and their consorts too. Pathogenic bacteria (the most common were Escherichia coli, Staphylococcus haemolyticus, Chlamydia trachomatis and Ureaplasma urealyticum) were isolated from the cervical swab of 50 pregnant patients with AIS in 86.0% of them, while in the control group of healthy pregnant women in 28.0%. Pathogenic bacteria were present in 70.0% of semen of consorts pregnant women with AIS and only in 30.0% of semen of the control group. The congruity of pathogenic bacteria in the cervical swab and semen in the investigated group was 69.2%, while only 35.7% in the control group. Following erythromycin, cefuroxime and local tetracyclin treatment, the negativization of the cervical swab resulted in 30 pregnant patients with AIS, while the colonization persisted in 20 of them. The outcome of pregnancy was significantly better in cases with negativization of the cervical swab: perinatal loss was 6.7%, while in cases with persistent infection it was 55.0%. The authors presume the amniotic infection syndrome should be ascending manifestation of nonspecific vaginitis, which is maintained by the consort's urogenital infection. AIS should be classified as a 'sexually-transmitted disease'. Copyright 2001 S. Karger AG, Basel

  18. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis.

    Science.gov (United States)

    Brody, Stuart; Weiss, Petr

    2010-08-01

    Evidence was recently provided for vaginal orgasm, orgasm triggered purely by penile-vaginal intercourse (PVI), being associated with better psychological functioning. Common sex education and sexual medicine approaches might undermine vaginal orgasm benefits. To examine the extent to which women's vaginal orgasm consistency is associated with (i) being told in childhood or adolescence that the vagina was the important zone for inducing female orgasm; (ii) how well they focus mentally on vaginal sensations during PVI; (iii) greater PVI duration; and (iv) preference for above-average penis length.   In a representative sample of the Czech population, 1,000 women reported their vaginal orgasm consistency (from never to almost every time; only 21.9% never had a vaginal orgasm), estimates of their typical foreplay and PVI durations, what they were told in childhood and adolescence was the important zone for inducing female orgasm, their degree of focus on vaginal sensations during PVI, and whether they were more likely to orgasm with a longer than average penis. The association of vaginal orgasm consistency with the predictors noted above. Vaginal orgasm consistency was associated with all hypothesized correlates. Multivariate analysis indicated the most important predictors were being educated that the vagina is important for female orgasm, being mentally focused on vaginal sensations during PVI, and in some analyses duration of PVI (but not foreplay) and preferring a longer than average penis. Focusing attention on penile-vaginal sensation supports vaginal orgasm and the myriad benefits thereof. Brody S, and Weiss P. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis. © 2009 International Society for Sexual Medicine.

  19. Improved stabilization scheme for computerized pulse-height analyzers

    International Nuclear Information System (INIS)

    Cohn, C.E.

    1982-01-01

    A stabilization scheme has been adapted from a 24-bit to a 16-bit computer. A precision pulse generator produces tagged reference pulses alternately of high and low amplitude. Gain and zero corrections are obtained from these and applied to each normal event. Provisions are made to make the system robust against pileup corruption of the reference pulses. (orig.)

  20. Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall.

    Science.gov (United States)

    Ripperda, Christopher M; Maldonado, Pedro Antonio; Acevedo, Jesus F; Keller, Patrick W; Akgul, Yucel; Shelton, John M; Word, Ruth Ann

    2017-07-01

    Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury.

  1. Patterns of Expression of Vaginal T-Cell Activation Markers during Estrogen-Maintained Vaginal Candidiasis

    Directory of Open Access Journals (Sweden)

    Al-Sadeq Ameera

    2008-12-01

    Full Text Available The immunosuppressive activity of estrogen was further investigated by assessing the pattern of expression of CD25, CD28, CD69, and CD152 on vaginal T cells during estrogen-maintained vaginal candidiasis. A precipitous and significant decrease in vaginal fungal burden toward the end of week 3 postinfection was concurrent with a significant increase in vaginal lymphocyte numbers. During this period, the percentage of CD3+, CD3+CD4+, CD152+, and CD28+ vaginal T cells gradually and significantly increased. The percentage of CD3+ and CD3+CD4+ cells increased from 43% and 15% at day 0 to 77% and 40% at day 28 postinfection. Compared with 29% CD152+ vaginal T cells in naive mice, > 70% of vaginal T cells were CD152+ at day 28 postinfection. In conclusion, estrogen-maintained vaginal candidiasis results in postinfection time-dependent changes in the pattern of expression of CD152, CD28, and other T-cell markers, suggesting that T cells are subject to mixed suppression and activation signals.

  2. Management of vaginal extrusion after tension-free vaginal tape procedure for urodynamic stress incontinence.

    Science.gov (United States)

    Giri, Subhasis K; Sil, Debasri; Narasimhulu, Girish; Flood, Hugh D; Skehan, Mark; Drumm, John

    2007-06-01

    To report our experience in the management of vaginal extrusion after the tension-free vaginal tape (TVT) procedure for urodynamic stress incontinence. Five patients diagnosed with vaginal extrusion after a TVT procedure performed at our institution were identified. We reviewed the patients' records retrospectively. The interval from TVT placement to diagnosis, presenting symptoms and signs, duration of symptoms, diagnostic test findings, treatment, and postoperative results were recorded. Patients were followed up for at least 12 months. From January 2001 to June 2004, a total of 166 patients underwent the TVT procedure. Of these, 5 patients (3%) were diagnosed with isolated vaginal extrusion 4 to 40 months postoperatively. No cases of urethral or bladder erosion occurred in this series. The symptoms included vaginal discharge, pain, bleeding, and dyspareunia. The eroded margin of the vaginal mucosa was trimmed, mobilized, and closed over the tape with interrupted vertical mattress sutures in a single layer using 2-0 polyglactin 910 to avoid mucosal inversion. All patients remained symptom free without any evidence of defective healing or additional extrusion at a minimal follow-up of 12 months. Primary reclosure of the vaginal mucosa over the TVT tape is an effective first-line treatment option for vaginal extrusion without compromising continence. Patients undergoing the TVT procedure should be adequately counseled about the possibility of this complication and the available treatment options.

  3. Focal depth measurements of the vaginal wall: a new method to noninvasively quantify vaginal wall thickness in the diagnosis and treatment of vaginal atrophy

    NARCIS (Netherlands)

    Weber, Maaike A.; Diedrich, Chantal M.; Ince, Can; Roovers, Jan-Paul

    2016-01-01

    The aim of the study was to evaluate if vaginal focal depth measurement could be a noninvasive method to quantify vaginal wall thickness. Postmenopausal women undergoing topical estrogen therapy because of vaginal atrophy (VA) were recruited. VA was diagnosed based on the presence of symptoms and

  4. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling

    Science.gov (United States)

    ITO, TAKUJI; BAI, TAO; TANAKA, TETSUJI; YOSHIDA, KENJI; UEYAMA, TAKASHI; MIYAJIMA, MASAYASU; NEGISHI, TAKAYUKI; KAWASAKI, TAKAHIKO; TAKAMATSU, HYOTA; KIKUTANI, HITOSHI; KUMANOGOH, ATSUSHI; YUKAWA, KAZUNORI

    2015-01-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild-type (WT) mice. Administration of β-estradiol to infant Sema4D-deficient (Sema4D−/−) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β-estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin-B1, was examined as well as the level of apoptosis in the vaginal epithelia of five-week-old WT and Sema4D−/− mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin-B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase-3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five-week-old Sema4D−/− mice compared with WT mice. The addition of recombinant Sema4D to Sema4D−/− vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis-inducing activity of Sema4D. The experimental reduction of

  5. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling.

    Science.gov (United States)

    Ito, Takuji; Bai, Tao; Tanaka, Tetsuji; Yoshida, Kenji; Ueyama, Takashi; Miyajima, Masayasu; Negishi, Takayuki; Kawasaki, Takahiko; Takamatsu, Hyota; Kikutani, Hitoshi; Kumanogoh, Atsushi; Yukawa, Kazunori

    2015-02-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild‑type (WT) mice. Administration of β‑estradiol to infant Sema4D‑deficient (Sema4D‑/‑) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β‑estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin‑B1, was examined as well as the level of apoptosis in the vaginal epithelia of five‑week‑old WT and Sema4D‑/‑ mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin‑B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase‑3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five‑week‑old Sema4D‑/‑ mice compared with WT mice. The addition of recombinant Sema4D to Sema4D‑/‑ vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis‑inducing activity of Sema4D. The

  6. Individualized Low-Amplitude Seizure Therapy: Minimizing Current for Electroconvulsive Therapy and Magnetic Seizure Therapy

    Science.gov (United States)

    Peterchev, Angel V; Krystal, Andrew D; Rosa, Moacyr A; Lisanby, Sarah H

    2015-01-01

    Electroconvulsive therapy (ECT) at conventional current amplitudes (800–900 mA) is highly effective but carries the risk of cognitive side effects. Lowering and individualizing the current amplitude may reduce side effects by virtue of a less intense and more focal electric field exposure in the brain, but this aspect of ECT dosing is largely unexplored. Magnetic seizure therapy (MST) induces a weaker and more focal electric field than ECT; however, the pulse amplitude is not individualized and the minimum amplitude required to induce a seizure is unknown. We titrated the amplitude of long stimulus trains (500 pulses) as a means of determining the minimum current amplitude required to induce a seizure with ECT (bilateral, right unilateral, bifrontal, and frontomedial electrode placements) and MST (round coil on vertex) in nonhuman primates. Furthermore, we investigated a novel method of predicting this amplitude-titrated seizure threshold (ST) by a non-convulsive measurement of motor threshold (MT) using single pulses delivered through the ECT electrodes or MST coil. Average STs were substantially lower than conventional pulse amplitudes (112–174 mA for ECT and 37.4% of maximum device amplitude for MST). ST was more variable in ECT than in MST. MT explained 63% of the ST variance and is hence the strongest known predictor of ST. These results indicate that seizures can be induced with less intense electric fields than conventional ECT that may be safer; efficacy and side effects should be evaluated in clinical studies. MT measurement could be a faster and safer alternative to empirical ST titration for ECT and MST. PMID:25920013

  7. Is vaginal microscopy an essential tool for the management of women presenting with vaginal discharge?

    Science.gov (United States)

    Lascar, R M; Devakumar, H; Jungmann, E; Copas, A; Arthur, G; Mercey, D

    2008-12-01

    Point-of-care microscopy is the gold standard for the diagnosis of vaginal discharge in genitourinary (GU) medicine clinics but not used in primary care settings and reproductive health clinics to which many patients present. In our GU medicine clinic setting, we conducted an audit to assess the utility of microscopy of vaginal secretions versus clinical diagnosis alone for the differential diagnosis of uncomplicated lower vaginal infections. Clinical diagnosis (including pH) of bacterial vaginosis had a sensitivity between 85% and 88% at two clinic sites. Our results suggest that it may be safe and more cost-effective to restrict vaginal microscopy to a subgroup of women presenting with vaginal discharge.

  8. PULSE SYNTHESIZING GENERATOR

    Science.gov (United States)

    Kerns, Q.A.

    1963-08-01

    >An electronlc circuit for synthesizing electrical current pulses having very fast rise times includes several sinewave generators tuned to progressively higher harmonic frequencies with signal amplitudes and phases selectable according to the Fourier series of the waveform that is to be synthesized. Phase control is provided by periodically triggering the generators at precisely controlled times. The outputs of the generators are combined in a coaxial transmission line. Any frequency-dependent delays that occur in the transmission line can be readily compensated for so that the desired signal wave shape is obtained at the output of the line. (AEC)

  9. Measurement of amplitude fluctuations in a rapid response photomultiplier; Mesure des fluctuations d'amplitude d'un photo multiplicateur a reponse rapide

    Energy Technology Data Exchange (ETDEWEB)

    Raimbault, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    In order to measure amplitude fluctuations in a rapid response photomultiplier, two independent random variables are introduced which determine the shape of the anode pulse. The energy of each pulse, which depends directly on the gain and the variance, is the first variable; amplitude fluctuations, functions of the first variable, depend as well on the pulse width which in turn constitutes the second variable. The results obtained on the variations of the maximum impulse, using a steep-edged pulse broadening circuit, and those obtained on the statistical variations of the gain, are compared to show that the variance relative to the maximum amplitude of the signal is greater than that of the gain. Within the limits of these fluctuations are shown the contribution of the secondary emission coefficient of the first dynode, and that of the mean secondary emission coefficient of the multiplier. (author) [French] Pour etudier les fluctuations d'amplitude d'un photomultiplicateur a reponse rapide, on introduit deux variables aleatoires independantes qui determinent la forme de l'impulsion anodique. L'energie de chaque impulsion, directement fonction du gain et de sa variance, est la premiere variable; les fluctuations d'amplitude, fonctions de la premiere variable, dependent egalement de la largeur de l'impulsion qui, elle, constitue la deuxieme variable. Les resultats obtenus sur les variations de l'amplitude maximale, a l'aide d'un circuit elargisseur d'impulsions a front raide, et les resultats des variations statistiques du gain sont compares pour mettre en evidence le fait que la variance relative a l'amplitude maximale du signal est plus grande que celle du gain. Dans la mesure de ces fluctuations, sont mises en evidence la contribution du coefficient d'emission secondaire de la premiere dynode et celle du coefficient d'emission secondaire moyen du multiplicateur. (auteur)

  10. Amplitude modulation reflectometer for FTU

    International Nuclear Information System (INIS)

    Zerbini, M.; Buratti, P.; Centioli, C.; Amadeo, P.

    1995-06-01

    Amplitude modulation (AM) reflectometry is a modification of the classical frequency sweep technique which allows to perform unambiguous phase delay measurements. An eight-channel AM reflectometer has been realized for the measurement of density profiles on the FTU tokamak in the range. The characteristics of the instrument have been determined in extensive laboratory tests; particular attention has been devoted to the effect of interference with parasitic reflections. The reflectometer is now operating on FTU. Some examples of the first experimental data are discussed

  11. Superstring amplitudes and contact interactions

    International Nuclear Information System (INIS)

    Greensite, J.

    1987-08-01

    We show that scattering amplitudes computed from light-cone superstring field theory are divergent at tree level. The divergences can be eliminated, and supersymmetry restored, by the addition of certain counter terms to the light-cone Hamiltonian. These counter terms have the form of local contact interactions, whose existence we had previously deduced on grounds of vacuum stability, and closure of the super-Poincare algebra. The quartic contact interactions required in Type I and Type IIB superstring theories are constructed in detail. (orig.)

  12. Forward amplitude in pion deuteron

    International Nuclear Information System (INIS)

    Ferreira, E.M.; Munguia, G.A.P.; Rosa, L.P.; Thome, Z.D.

    1979-06-01

    The data on total cross section for πd scattering is analysed in terms of a single scattering calculation with Fermi motion dependence, in order to obtain a criterion to fix the value of the energy entering the two body meson nucleon amplitude. It is found that the prescription derived from the non-relativistic three body kinematics gives reasonable results. The introduction of a shift in the energy value, possibly representing nuclear binding effects, leads to a very good fitting of the data. The results are compared with those obtained in direct calculations of Faddeev equations and with the Brueckner model of fixed scatterers. (Author) [pt

  13. Aerobic vaginal pathogens and their sensitivity pattern.

    Science.gov (United States)

    Mumtaz, Shamim; Ahmad, Mumtaz; Aftab, Irum; Akhtar, Naeem; ul Hassan, Masood; Hamid, Abdul

    2008-01-01

    The vaginal flora is a complicated environment, containing dozens of microbiological species in variable quantities and relative proportions. The frequent cause of vaginal discharge is an infection or colonization with different microorganisms. Some pathologic conditions causing vaginitis are well defined yet, 7-72% of women with vaginitis may remain undiagnosed and such forms of abnormal vaginal flora neither considered as normal, nor can be called bacterial vaginosis have been termed as 'intermediate flora' and its management probably differ from that of bacterial vaginosis. It is of crucial importance in pregnant females at risk of preterm delivery. The present study has been conducted especially to elucidate this type of aerobic vaginal isolates and their culture and sensitivity towards currently used antibiotics. This study was conducted at the Microbiology Department of Fauji Foundation Hospital, Rawalpindi over a period of two years (April 2004-March 2006). One thousand, nine hundred and twenty three high vaginal swabs, both from indoor and outdoor patients were collected, cultured and their susceptibility to various antibiotics was determined. Significant growth was obtained in 731 samples. The highest frequency of infection (39.5%) was observed at 31-40 years followed by 41-50 years (35.8%). About 76% were from outdoor and 24% were from indoor patients. Staphylococcus aureus was the most prevalent vaginal pathogen at 11-60 yrs & with highest prevalence at 31-40 years followed by 41-50 years. It was a predominant pathogen in both indoor (35%) as well as outdoor (41.6%) patients, followed by enteric gram-negative bacilli and other gram-positive cocci. There were very few antibiotics among the conventionally available aminoglycosides, third generation cephalosporins, penicillin, quinolones, sulfonamides and tetracyclines possessing good sensitivity (> 80%) against any one the common aerobic vaginal pathogens. The effective chemotherapeutics agents belong to

  14. EVOLUTION OF FAST MAGNETOACOUSTIC PULSES IN RANDOMLY STRUCTURED CORONAL PLASMAS

    International Nuclear Information System (INIS)

    Yuan, D.; Li, B.; Pascoe, D. J.; Nakariakov, V. M.; Keppens, R.

    2015-01-01

    We investigate the evolution of fast magnetoacoustic pulses in randomly structured plasmas, in the context of large-scale propagating waves in the solar atmosphere. We perform one-dimensional numerical simulations of fast wave pulses propagating perpendicular to a constant magnetic field in a low-β plasma with a random density profile across the field. Both linear and nonlinear regimes are considered. We study how the evolution of the pulse amplitude and width depends on their initial values and the parameters of the random structuring. Acting as a dispersive medium, a randomly structured plasma causes amplitude attenuation and width broadening of the fast wave pulses. After the passage of the main pulse, secondary propagating and standing fast waves appear. Width evolution of both linear and nonlinear pulses can be well approximated by linear functions; however, narrow pulses may have zero or negative broadening. This arises because narrow pulses are prone to splitting, while broad pulses usually deviate less from their initial Gaussian shape and form ripple structures on top of the main pulse. Linear pulses decay at an almost constant rate, while nonlinear pulses decay exponentially. A pulse interacts most efficiently with a random medium with a correlation length of about half of the initial pulse width. This detailed model of fast wave pulses propagating in highly structured media substantiates the interpretation of EIT waves as fast magnetoacoustic waves. Evolution of a fast pulse provides us with a novel method to diagnose the sub-resolution filamentation of the solar atmosphere

  15. Screening of mucoadhesive vaginal gel formulations

    Directory of Open Access Journals (Sweden)

    Ana Ochoa Andrade

    2014-12-01

    Full Text Available Rational design of vaginal drug delivery formulations requires special attention to vehicle properties that optimize vaginal coating and retention. The aim of the present work was to perform a screening of mucoadhesive vaginal gels formulated with carbomer or carrageenan in binary combination with a second polymer (carbomer, guar or xanthan gum. The gels were characterised using in vitroadhesion, spreadability and leakage potential studies, as well as rheological measurements (stress and frequency sweep tests and the effect of dilution with simulated vaginal fluid (SVF on spreadability. Results were analysed using analysis of variance and multiple factor analysis. The combination of polymers enhanced adhesion of both primary gelling agents, carbomer and carrageenan. From the rheological point of view all formulations presented a similar behaviour, prevalently elastic and characterised by loss tangent values well below 1. No correlation between rheological and adhesion behaviour was found. Carbomer and carrageenan gels containing the highest percentage of xanthan gum displayed good in vitro mucoadhesion and spreadability, minimal leakage potential and high resistance to dilution. The positive results obtained with carrageenan-xanthan gum-based gels can encourage the use of natural biocompatible adjuvants in the composition of vaginal products, a formulation field that is currently under the synthetic domain.

  16. The vaginal microbiota and susceptibility to HIV.

    Science.gov (United States)

    Buve, Anne; Jespers, Vicky; Crucitti, Tania; Fichorova, Raina N

    2014-10-23

    There is some evidence that the risk of HIV infection per heterosexual act is higher in low-income countries than in high-income countries. We hypothesize that variations in per sex-act transmission probability of HIV may in part be attributed to differences in the composition and function of the vaginal microbiota between different populations. This paper presents data that are in support of this hypothesis. Experimental and clinical studies have provided evidence that the normal vaginal microbiota plays a protective role against acquisition of HIV and other sexually transmitted infections. Epidemiological studies have convincingly shown that disturbances of the vaginal microbiome, namely intermediate flora and bacterial vaginosis, increase the risk of acquisition of HIV infection. A review of the literature found large differences in prevalence of bacterial vaginosis between different populations, with the highest prevalence rates found in black populations. Possible explanations for these differences are presented including data suggesting that there are ethnic differences in the composition of the normal vaginal microbiota. Lastly, interventions are discussed to restore and maintain a healthy vaginal environment. 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins

  17. Group B Streptococcus and the Vaginal Microbiota.

    Science.gov (United States)

    Rosen, Geoffrey H; Randis, Tara M; Desai, Purnahamsi V; Sapra, Katherine J; Ma, Bing; Gajer, Pawel; Humphrys, Michael S; Ravel, Jacques; Gelber, Shari E; Ratner, Adam J

    2017-09-15

    Streptococcus agalactiae (group B Streptococcus [GBS]) is an important neonatal pathogen and emerging cause of disease in adults. The major risk factor for neonatal disease is maternal vaginal colonization. However, little is known about the relationship between GBS and vaginal microbiota. Vaginal lavage samples from nonpregnant women were tested for GBS, and amplicon-based sequencing targeting the 16S ribosomal RNA V3-V4 region was performed. Four hundred twenty-eight of 432 samples met the high-quality read threshold. There was no relationship between GBS carriage and demographic characteristics, α-diversity, or overall vaginal microbiota community state type (CST). Within the non-Lactobacillus-dominant CST IV, GBS positive status was significantly more prevalent in CST IV-A than CST IV-B. Significant clustering by GBS status was noted on principal coordinates analysis, and 18 individual taxa were found to be significantly associated with GBS carriage by linear discriminant analysis. After adjusting for race/ethnicity, 4 taxa were positively associated with GBS, and 6 were negatively associated. Vaginal microbiota CST and α-diversity are not related to GBS status. However, specific microbial taxa are associated with colonization of this important human pathogen, highlighting a potential role for the microbiota in promotion or inhibition of GBS colonization. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  18. Diagnostic and therapeutic advancements for aerobic vaginitis.

    Science.gov (United States)

    Han, Cha; Wu, Wenjuan; Fan, Aiping; Wang, Yingmei; Zhang, Huiying; Chu, Zanjun; Wang, Chen; Xue, Fengxia

    2015-02-01

    Aerobic vaginitis (AV) is a newly defined clinical entity that is distinct from candidiasis, trichomoniasis and bacterial vaginosis (BV). Because of the poor recognition of AV, this condition can lead to treatment failures and is associated with severe complications, such as pelvic inflammatory disease, infertility, preterm birth and foetal infections. This review describes the diagnosis and treatment of AV and the relationship between AV and pregnancy. The characteristics of AV include severely depressed levels of lactobacilli, increased levels of aerobic bacteria and an inflamed vagina. The diagnosis is made by microscopy on wet mounts of fresh vaginal fluid, and some distinct clinical features are recognized. Vaginal suppositories that contain kanamycin or clindamycin have shown curative effects in nonpregnant women. Additionally, the application of topical probiotics can restore the vaginal flora and reduce the recurrence of AV. Clindamycin vaginal suppositories and probiotics may be a better choice for gravida with AV than metronidazole. AV requires prompt attention, and the early diagnosis and treatment of AV during pregnancy significantly improves perinatal outcomes. Further research is needed to define the pathogenesis, diagnostic criteria and standard treatment guidelines for AV.

  19. [Vaginitis and vaginosis. Comparison of two periods].

    Science.gov (United States)

    Ceruti, M; Canestrelli, M; Piantelli, G; Amone, F; Condemi, V; De Paolis, P; Ludovici, G; Somenzi, P

    1993-10-01

    Vaginitis is the most frequent gynecological disease. It is characterized by objective and subjective signs of inflammation and differs from bacterial vaginosis (BV) which is an abnormal condition of the vaginal ecosystem caused by the excessive growth of aerobic and anaerobic flora normally present in the vagina with an increased risk of pelvic inflammatory disease (PID). The authors report the results of a study carried out at the Centre for Gynecological Infections at the Clinic of Obstetrics and Gynecology of the University of Parma. 828 patients were enrolled in the study during the period 1985-86 and 1559 patients during the two-year period 1991-92. The aim of the study was to evaluate variations in epidemiological data for vaginitis and bacterial vaginosis in the two periods examined. No significant changes were observed (p > 0.05) with regard to the prevalence of Ca, Tv and BV forms. On the other hand, there was a significant reduction (p vaginitis and BV showed a reduction of other microorganisms and an increase in negative vaginal swabs in adults (> 20 years old).

  20. Pulsed inductive HF laser

    Energy Technology Data Exchange (ETDEWEB)

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S; Demchuk, S V [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    We report the results of experimentally investigated dependences of temporal, spectral and spatial characteristics of an inductive HF-laser generation on the pump conditions. Gas mixtures H{sub 2} – F{sub 2}(NF{sub 3} or SF6{sub 6}) and He(Ne) – H{sub 2} – F{sub 2}(NF{sub 3} or SF{sub 6}) were used as active media. The FWHM pulse duration reached 0.42 μs. This value corresponded to a pulsed power of 45 kW. For the first time, the emission spectrum of an inductive HF laser was investigated, which consisted of seven groups of bands with centres around the wavelengths of 2732, 2736, 2739, 2835, 2837, 2893 and 2913 nm. The cross section profile of the laser beam was a ring with a diameter of about 20 mm and width of about 5 mm. Parameters of laser operation in the repetitively pulsed regime were sufficiently stable. The amplitude instability of light pulses was no greater than 5% – 6%. (lasers)

  1. Reviewing the options for local estrogen treatment of vaginal atrophy

    Directory of Open Access Journals (Sweden)

    Lindahl SH

    2014-03-01

    Full Text Available Sarah H Lindahl Sutter East Bay Medical Foundation, SEBMF – Diablo Division, Castro Valley, CA, USA Background: Vaginal atrophy is a chronic condition with symptoms that include vaginal dryness, pain during sex, itching, irritation, burning, and discharge, as well as various urinary problems. Up to 45% of postmenopausal women may be affected, but it often remains underreported and undertreated. This article aims to review the current recommendations for treatment of vaginal atrophy, and current data on the effectiveness and safety of local vaginal estrogen therapies. Methods: Literature regarding vaginal atrophy (2007–2012 was retrieved from PubMed and summarized, with emphasis on data related to the treatment of vaginal atrophy with local vaginal estrogen therapy. Results: Published data support the effectiveness and endometrial safety of low-dose local estrogen therapies. These results further support the general recommendation by the North American Menopause Society that a progestogen is not needed for endometrial protection in patients using low-dose local vaginal estrogen. Benefits of long-term therapy for vaginal atrophy include sustained relief of symptoms as well as physiological improvements (eg, decreased vaginal pH and increased blood flow, epithelial thickness, secretions. Conclusion: Currently available local vaginal estrogen therapies are well tolerated and effective in relieving symptoms of vaginal atrophy. Recent data support the endometrial safety of low-dose regimens for up to 1 year. Keywords: menopause, estrogen, local estrogen therapy, vaginal atrophy

  2. [Clinical characteristics of aerobic vaginitis and its mixed infections].

    Science.gov (United States)

    Fan, Ai-Ping; Xue, Feng-Xia

    2010-12-01

    To investigate clinical characteristics of aerobic vaginitis (AV) and its mixed infections for diagnosis efficiently. From April 2008 to December 2008, 516 patients with vaginitis treated in Tianjin Medical University General Hospital were enrolled in this study. AV, bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), trichomonal vaginitis (TV), and cytolytic vaginosis (CV) were diagnosed based on symptoms, sign and vaginal discharge examination. Among 516 cases, AV cases were found in 14.7% (76/516), and AV was common vaginal infection. AV mixed infections was diagnosed in 58% (44/76), including mixed with BV (45%, 20/44), mixed with VVC (30%, 13/44), and mixed with TV (25%, 11/44). Those common symptom of AV were yellow vaginal discharge (63%, 20/32), more vaginal discharge (44%, 14/32). Vaginal pH value was usually more than 4.5 (84%, 27/32). Vaginal cleanliness mainly was grade III - IV (88%, 28/32). Six cases with enterococcus faecium and 4 cases with streptococci were frequently isolated. The symptom and sign of mixed AV infection was atypical. Aerobic vaginitis is a common lower vaginal infection and easily mixed with other pathogens, especially with BV, VVC or TV. When patients were diagnosed with AV or other vaginal infection, it should be mentioned whether those patients have mixed vaginal infection or AV.

  3. Responses to amplitude modulated infrared stimuli in the guinea pig inferior colliculus

    Science.gov (United States)

    Richter, Claus-Peter; Young, Hunter

    2013-03-01

    Responses of units in the central nucleus of the inferior colliculus of the guinea pig were recorded with tungsten electrodes. The set of data presented here is limited to high stimulus levels. The effect of changing the modulation frequency and the modulation depth was explored for acoustic and laser stimuli. The selected units responded to sinusoidal amplitude modulated (AM) tones, AM trains of clicks, and AM trains of laser pulses with a modulation of their spike discharge. At modulation frequencies of 20 Hz, some units tended to respond with 40 Hz to the acoustic stimuli, but only at 20 Hz for the trains of laser pulses. For all modes of stimulation the responses revealed a dominant response to the first cycle of the modulation, with decreasing number of action potential during successive cycles. While amplitude modulated tone bursts and amplitude modulated trains of acoustic clicks showed similar patterns, the response to trains of laser pulses was different.

  4. Observation of large-amplitude ion acoustic solitary waves in a plasma

    International Nuclear Information System (INIS)

    Nakamura, Yoshiharu

    1987-01-01

    Propagation of nonlinear ion acoustic waves in a multi-component plasma with negative ions is investigated in a double-plasma device. When the density of negative ions is larger than a critical value, a broad negative pulse evolves to rarefactive solitons, and a positive pulse whose amplitude is less than a certain threshold value becomes a subsonic wave train. In the same plasma, a positive pulse whose amplitude is larger than the threshold develops into a solitary wave. The critical amplitude is measured as a function of the density of negative ions and compared with predictions of the pseudo-potential method. The energy distribution of electrons in the solitary wave is also measured. (author)

  5. High current high accuracy IGBT pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.V.; Donaldson, A.R.

    1995-05-01

    A solid state pulse generator capable of delivering high current triangular or trapezoidal pulses into an inductive load has been developed at SLAC. Energy stored in a capacitor bank of the pulse generator is switched to the load through a pair of insulated gate bipolar transistors (IGBT). The circuit can then recover the remaining energy and transfer it back to the capacitor bank without reversing the capacitor voltage. A third IGBT device is employed to control the initial charge to the capacitor bank, a command charging technique, and to compensate for pulse to pulse power losses. The rack mounted pulse generator contains a 525 μF capacitor bank. It can deliver 500 A at 900V into inductive loads up to 3 mH. The current amplitude and discharge time are controlled to 0.02% accuracy by a precision controller through the SLAC central computer system. This pulse generator drives a series pair of extraction dipoles

  6. Amplitude modulation of atomic wave functions. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    The major theoretical advance has been to show that one can modulate Rydberg wave functions using either of two methods: (1) the amplitude modulation technique which depends on autoionization to deplete part of the wave function, or (2) a phase modulation method, which uses a change in the core potential to create a localized phase shift in the wave function. Essentially, these two methods can both be seen as using the core potential to change the Rydberg wave function, using the imaginary part of the potential to do amplitude modulation, or using the real part of the potential to do phase modulation. This work will be published as the authors acquire experimental results which show the differences between the two methods. One of the results of this theoretical study is that the initial proposal to study Barium 6snd states had a significant flaw. Neither the autoionization time, nor the quantum defect shifts are very large in these cases. This means that the modulation is relatively small. This shows itself primarily in the difficulty of seeing significant population redistribution into different 6snd states. The authors intend to correct this in the next funding cycle either: (a) by using the more quickly decaying Ba 6pnf states to modulate 6snd states, or (b) by using Sr 5 snd states, as outlined in this report. Their first, low power experiments are complete. These experiments have used two pulses to do a temporal version of the Ramsey separated oscillatory fields excitation. The two pulses are generated by passing the single pulse through a Michelson-Morley interferometer, which is computer controlled to sweep one arm through 2.5 {micro}m in steps of 10 nm. The second pulse`s excitation interferes with that of the first pulse, and so the total excitation has a sinusoidal variation (with a time period equal to the optical period) on top of a constant background. The amplitude of the total variation should decay at half of the rate decay rate of the autoionizing

  7. Bacterial vaginosis and vaginal yeast, but not vaginal cleansing, increase HIV-1 acquisition in African women.

    Science.gov (United States)

    van de Wijgert, Janneke H H M; Morrison, Charles S; Cornelisse, Peter G A; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; Van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A; Padian, Nancy S

    2008-06-01

    To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women aged 18 to 35 years attending family planning clinics in Zimbabwe and Uganda. Participants were tested for HIV and reproductive tract infections and were interviewed about vaginal practices every 3 months for 15 to 24 months. BV was measured by Gram stain Nugent scoring, vaginal yeast by wet mount, and mucosal inflammation by white blood cells on Gram stain. HIV incidence was 4.12 and 1.53 per 100 woman-years of follow-up in Zimbabwe and Uganda, respectively (a total of 213 incident infections). Women with BV or vaginal yeast were more likely to acquire HIV, especially if the condition was present at the same visit as the new HIV infection and the visit preceding it (hazard ratio [HR] = 2.50, 95% confidence interval [CI]: 1.68 to 3.72 and HR = 2.97, 95% CI: 1.67 to 5.28 for BV and yeast, respectively). These relationships did not seem to be mediated by mucosal inflammation. Vaginal drying/tightening was associated with HIV acquisition in univariate (HR = 1.49, 95% CI: 1.03 to 2.15) but not multivariate models. Vaginal cleansing was not associated with HIV acquisition. BV and yeast may contribute more to the HIV epidemic than previously thought.

  8. The Comparison of vaginal cream of mixing yogurt, honey and clotrimazole on symptoms of vaginal candidiasis.

    Science.gov (United States)

    Darvishi, Maryam; Jahdi, Fereshteh; Hamzegardeshi, Zeinab; Goodarzi, Saied; Vahedi, Mohsen

    2015-04-03

    Vulvovaginal candidiasis is known as one of the most common fungal infection among women of reproductive age and considered as an important public health problem. In recent years, due to resistance to common antifungal medication, the use of traditional medicine of anti-fungal and herbal treatment increased. Therefore the objective of this study was to determine the effects of vaginal cream, mixture of yogurt and honey and comparing it with clotrimazole vaginal cream on symptoms of Vulvovaginal candidiasis in patients. In this randomized, triple blind clinical trial of 70 non-pregnant women infected with Candidal vulvovaginitis were placed in two groups of Vaginal cream mixed of yogurt and honey recipients (N=35) and clotrimazole vaginal cream (N=35). Both groups were treated for 7 days. At the beginning of study, Clinical and laboratory signs and symptoms were registered 7 and 14 days after treatment by questionnaire, observation form and secretions culture results. Data by chi-square test, t test, McNemar tests were analyzed by SPSS version 21. Significance level of 0.05 was considered. The result of present study reveals the significant differences in symptom improvement of ' yogurt and honey, than clotrimazole group (P0.05) CONCLUSION: This study indicated that he therapeutic effects of vaginal cream, yogurt and honey is not only similar with clotrimazole vaginal cream but more effective in relieving some symptoms of vaginal candidiasis. Therefore, the use of this product can be suggested as an herbal remedy for candida infection treatment.

  9. Vaginal lactobacilli profile in pregnant women with normal & abnormal vaginal flora.

    Science.gov (United States)

    Yeruva, Thirupathaiah; Rajkumar, Hemalatha; Donugama, Vasundhara

    2017-10-01

    Lactobacilli species that are better adapted to vaginal environment of women may colonize better and offer protection against vaginal pathogenic bacteria. In this study, the distribution of common Lactobacillus species was investigated in pregnant women. Sixty seven pregnant women were included in the study and vaginal samples were collected for Gram staining. Women were classified as normal vaginal flora, intermediate flora and bacterial vaginosis (BV) based on Nugent's score. Vaginal samples were also collected for the identification of Lactobacillus spp. by multiplex polymerase chain reaction (PCR) profiling of 16S rDNA amplification method. Lactobacillus crispatus (100%) was the most predominant Lactobacillus spp. present in pregnant women with normal flora, followed by L. iners (77%), L. jensenii (74%) and L. helveticus (60%). While, L. iners was commonly present across groups in women with normal, intermediate or BV flora, L. crispatus, L. jensenii and L. helveticus decreased significantly as the vaginal flora changed to intermediate and BV. In women with BV, except L. iners other species of lactobacilli was less frequently prevalent. Species such as L. rhamnosus, L. fermentum, L. paracasei and L. casei were not detected in any vaginal sample. L. crispatus, L. jensinii and L. helveticus were predominant species in women with normal flora. L. crispatus alone or in combination with L. jensinii and L. helveticus may be evaluated for probiotic properties for the prevention and treatment of BV.

  10. Vaginal rings for delivery of HIV microbicides

    Directory of Open Access Journals (Sweden)

    McCoy CF

    2012-11-01

    Full Text Available R Karl Malcolm, Susan M Fetherston, Clare F McCoy, Peter Boyd, Ian MajorSchool of Pharmacy, Queen's University Belfast, Belfast, UKAbstract: Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing.Keywords: controlled release, sustained release, antiretroviral, dapivirine, SILCS diaphragm, silicone elastomer, thermoplastic

  11. Protective activity of geranium oil and its component, geraniol, in combination with vaginal washing against vaginal candidiasis in mice.

    Science.gov (United States)

    Maruyama, Naho; Takizawa, Toshio; Ishibashi, Hiroko; Hisajima, Tatsuya; Inouye, Shigeharu; Yamaguchi, Hideyo; Abe, Shigeru

    2008-08-01

    In order to evaluate an effective administration method of essential oils for vaginal candidiasis, efficacy of vaginal application of essential oils against murine experimental candidiasis was investigated. The effect on vaginal inflammation and Candida growth form was also studied. Vaginal candidiasis was established by intravaginal infection of C. albicans to estradiol-treated mice. These mice intravaginally received essential oils such as geranium and tea tree singly or in combination with vaginal washing. Vaginal administration of clotrimazole significantly decreased the number of viable C. albicans cells in the vaginal cavity by itself. In contrast, these essential oils did not lower the cell number. When application of geranium oil or geraniol was combined with vaginal washing, the cell number was decreased significantly. The myeloperoxidase activity assay exhibited the possibility that essential oils worked not only to reduce the viable cell number of C. albicans, but also to improve vaginal inflammation. The smear of vaginal washing suspension suggested that more yeast-form cells appeared in vaginal smears of these oil-treated mice than in control mice. In vitro study showed that a very low concentration (25 microg/ml) of geranium oil and geraniol inhibited mycelial growth, but not yeast growth. Based on these findings, it is estimated that vaginal application of geranium oil or its main component, geraniol, suppressed Candida cell growth in the vagina and its local inflammation when combined with vaginal washing.

  12. Anterior vaginal wall repair (surgical treatment of urinary incontinence) - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100110.htm Anterior vaginal wall repair (surgical treatment of urinary incontinence) - series— ... to slide 4 out of 4 Overview The vaginal opening lies just below the urethral opening, and ...

  13. Preliminary findings on vaginal epithelial cells and body ...

    African Journals Online (AJOL)

    Dr Gatsing

    sahelian zone of. Cameroon, in order to assess vaginal cytology and body temperature variations during oestrous cycle. Swabbing was done daily in the vagina, and vaginal smears were stained according to Romanowski method.

  14. prevalence and risk factors for vaginal candidiasis among women

    African Journals Online (AJOL)

    hi-tech

    2005-03-01

    Mar 1, 2005 ... Conculsion: The high prevalence of vaginal candidiasis among women with genital infections ... complaints of either abnormal vaginal discharge, lower abdominal or pelvic ..... is in keeping with the reports in literature (8). The.

  15. The detection and estimation of spurious pulses

    International Nuclear Information System (INIS)

    1976-01-01

    Spurious pulses which may interfere with the counting of particles can sometimes easily be detected by integral counting as a function of amplification or by pulse-height analysis. However, in order to estimate their count rate, more elaborate methods based on their time relationship are needed. Direct techniques (delayed coincidences, use of a multichannel analyser in time mode, time-to-amplitude conversion) and gating techniques (simple subtraction, correlation counting, pulsed sources, modulo counting) are discussed. These techniques are compared to each other and their application to various detectors is studied as well as the influence of a dead time on spurious pulses

  16. Pregnancy's stronghold on the vaginal microbiome.

    Directory of Open Access Journals (Sweden)

    Marina R S Walther-António

    Full Text Available To assess the vaginal microbiome throughout full-term uncomplicated pregnancy.Vaginal swabs were obtained from twelve pregnant women at 8-week intervals throughout their uncomplicated pregnancies. Patients with symptoms of vaginal infection or with recent antibiotic use were excluded. Swabs were obtained from the posterior fornix and cervix at 8-12, 17-21, 27-31, and 36-38 weeks of gestation. The microbial community was profiled using hypervariable tag sequencing of the V3-V5 region of the 16S rRNA gene, producing approximately 8 million reads on the Illumina MiSeq.Samples were dominated by a single genus, Lactobacillus, and exhibited low species diversity. For a majority of the patients (n = 8, the vaginal microbiome was dominated by Lactobacillus crispatus throughout pregnancy. Two patients showed Lactobacillus iners dominance during the course of pregnancy, and two showed a shift between the first and second trimester from L. crispatus to L. iners dominance. In all of the samples only these two species were identified, and were found at an abundance of higher than 1% in this study. Comparative analyses also showed that the vaginal microbiome during pregnancy is characterized by a marked dominance of Lactobacillus species in both Caucasian and African-American subjects. In addition, our Caucasian subject population clustered by trimester and progressed towards a common attractor while African-American women clustered by subject instead and did not progress towards a common attractor.Our analyses indicate normal pregnancy is characterized by a microbiome that has low diversity and high stability. While Lactobacillus species strongly dominate the vaginal environment during pregnancy across the two studied ethnicities, observed differences between the longitudinal dynamics of the analyzed populations may contribute to divergent risk for pregnancy complications. This helps establish a baseline for investigating the role of the microbiome in

  17. Vesicovaginal fistula repair through vaginal approach

    International Nuclear Information System (INIS)

    Ashraf, S.; Rahim, J.

    2014-01-01

    Objectives: To evaluate the outcome of trans-vaginal repair of vesico-vaginal fistula through vaginal approach. Study Design: Prospective study. Material and Methods: This study was carried out in Department of Urology, Shaikh Zayed Postgraduate Medical Institute and National institute of Kidney Diseases, Lahore for the period extending from April 2009 to April 2014. Total 17 patients were included in the study. History, physical examination and findings on investigations were reviewed. In all patients cystoscopy and vaginal examination was performed to see fistula site and ureteral orfices. Then trans-vaginal repair was done in all cases. Results: VVF repair was performed on 17 patients aging 25 to 45 years (mean 35.83 ± 7.37 years). The symptoms preceded for a period of 3 months to 8 years. The cause was gynecological hysterectomy 8 (47.05%), obstetric C-section 7 (41.17%) and obstructed labor 2(11.76%). In three of our patients VVF was previously repaired trans-abdominally. On cystoscopy no patients had more than one fistula. In two (11.76%) patients fistula was supratrigonal. The average size of fistula was 2.05 em, detail of fistula site and size is given in table. One patient had leakage on second postop day that was managed with change of Foleys catheter. Successful repair was achieved in all patients and no patient required second attempt. No ureteric injury and other complications were observed. Conclusion: Trans-vaginal repair of VVF avoid laparotomy and bladder bisection. It has reduced hospital stay and morbidity. (author)

  18. Directed shift of vaginal microbiota induced by vaginal application of sucrose gel in rhesus macaques.

    Science.gov (United States)

    Hu, Kai-tao; Zheng, Jin-xin; Yu, Zhi-jian; Chen, Zhong; Cheng, Hang; Pan, Wei-guang; Yang, Wei-zhi; Wang, Hong-yan; Deng, Qi-wen; Zeng, Zhong-ming

    2015-04-01

    Sucrose gel was used to treat bacterial vaginosis in a phase III clinical trial. However, the changes of vaginal flora after treatment were only examined by Nugent score in that clinical trial, While the vaginal microbiota of rhesus macaques is characterized by anaerobic, Gram-negative bacteria, few lactobacilli, and pH levels above 4.6, similar to the microbiota of patients with bacterial vaginosis. This study is aimed to investigate the change of the vaginal microbiota of rehsus macaques after topical use of sucrose gel to reveal more precisely the bacterial population shift after the topical application of sucrose gel. Sixteen rhesus macaques were treated with 0.5 g sucrose gel vaginally and three with 0.5 g of placebo gel. Vaginal swabs were collected daily following treatment. Vaginal pH levels and Nugent scores were recorded. The composition of the vaginal micotbiota was tested by V3∼V4 16S rDNA metagenomic sequencing. Dynamic changes in the Lactobacillus genus were analyzed by qPCR. The vaginal microbiota of rhesus macaques are dominated by anaerobic Gram-negative bacteria, with few lactobacilli and high pH levels above 4.6. After five days' treatment with topical sucrose gel, the component percentage of Lactobacillus in vaginal microbiota increased from 1.31% to 81.59%, while the component percentage of Porphyromonas decreased from 18.60% to 0.43%, Sneathia decreased from 15.09% to 0.89%, Mobiluncus decreased from 8.23% to 0.12%, etc.. The average vaginal pH values of 16 rhesus macaques of the sucrose gel group decreased from 5.4 to 3.89. There were no significant changes in microbiota and vaginal pH observed in the placebo group. Rhesus macaques can be used as animal models of bacterial vaginosis to develop drugs and test treatment efficacy. Furthermore, the topical application of sucrose gel induced the shifting of vaginal flora of rhesus macaques from a BV kind of flora to a lactobacilli-dominating flora. Copyright © 2015 The Authors. Published by

  19. The interaction between vaginal microbiota, cervical length, and vaginal progesterone treatment for preterm birth risk

    OpenAIRE

    Kindinger, Lindsay M.; Bennett, Phillip R.; Lee, Yun S; Marchesi, Julian R.; Smith, Ann; Cacciatore, Stefano; Holmes, Elaine; Nicholson, Jeremy K.; Teoh, T. G.; MacIntyre, David A.

    2017-01-01

    Background Preterm birth is the primary cause of infant death worldwide. A short cervix in the second trimester of pregnancy is a risk factor for preterm birth. In specific patient cohorts, vaginal progesterone reduces this risk. Using 16S rRNA gene sequencing, we undertook a prospective study in women at risk of preterm birth (n?=?161) to assess (1) the relationship between vaginal microbiota and cervical length in the second trimester and preterm birth risk and (2) the impact of vaginal pro...

  20. Parto vaginal tras cesárea

    OpenAIRE

    San Martín Bragado, María

    2016-01-01

    Cuando una mujer ha sido sometida a una cesárea previa existen dos opciones para ella en el caso de que se quede embarazada: repetir cesárea o intentar un parto vaginal. A pesar de los riesgos, el parto vaginal después de una cesárea es una situación atractiva para muchas pacientes y dará lugar a un resultado exitoso en un alto porcentaje de casos. Se ha de tener en cuenta que la realización de una cesárea electiva no está exenta de riesgos Grado en Medicina

  1. Fanconi anemia and vaginal squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Jesus Paula Carvalho

    2012-01-01

    Full Text Available Fanconi Anemia (FA is an autosomal recessive disease characterized by chromosome instability, cellular hypersensitivity to DNA cross-linking agents, and increased predisposition to malignancies. We describe here a 28 year-old female with FA and vaginal squamous cell carcinoma treated by radiation therapy alone. The patient developed arm phlebitis, pulmonary fungal infection, and severe rectal bleeding, followed by hypocalcaemia, hypokalemia, vaginal bacterial and fungal infection, with subsequent leg and arm phlebitis, perineal abscess, and sepsis. The patient died 12 weeks later.

  2. [Bacteriological aspects of trichomonal vaginitis (author's transl)].

    Science.gov (United States)

    Brockmann, J; Höhne, C

    1979-01-01

    An analysis was made of the vaginal flora of 25 gynaecological patients with acute trichomomal vaginitis, with the view to elucidating the bacteriological situation. Eighty-four isolates, an average of 3.4 per patient, were taken and included a wide range of aerobic and anaerobic bacteria. - Obligate anaerobic species, such as bacteriodes and peptostreptococci, with susceptibility to metronidazole were among the predominant pathogens. - The differentiated susceptibility of the most common bacteria to antibiotics may yield information useful to therapy in the case of aggravated infection.

  3. Covariant amplitudes in Polyakov string theory

    International Nuclear Information System (INIS)

    Aoyama, H.; Dhar, A.; Namazie, M.A.

    1986-01-01

    A manifestly Lorentz-covariant and reparametrization-invariant procedure for computing string amplitudes using Polyakov's formulation is described. Both bosonic and superstring theories are dealt with. The computation of string amplitudes is greatly facilitated by this formalism. (orig.)

  4. Amplitude Variations in Pulsating Red Giants. II. Some Systematics

    Science.gov (United States)

    Percy, J. R.; Laing, J.

    2017-12-01

    In order to extend our previous studies of the unexplained phenomenon of cyclic amplitude variations in pulsating red giants, we have used the AAVSO time-series analysis package vstar to analyze long-term AAVSO visual observations of 50 such stars, mostly Mira stars. The relative amount of the variation, typically a factor of 1.5, and the time scale of the variation, typically 20-35 pulsation periods, are not significantly different in longer-period, shorter-period, and carbon stars in our sample, and they also occur in stars whose period is changing secularly, perhaps due to a thermal pulse. The time scale of the variations is similar to that in smaller-amplitude SR variables, but the relative amount of the variation appears to be larger in smaller-amplitude stars, and is therefore more conspicuous. The cause of the amplitude variations remains unclear, though they may be due to rotational modulation of a star whose pulsating surface is dominated by the effects of large convective cells.

  5. Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

    International Nuclear Information System (INIS)

    Shin, Young Kil; Choi, Dong Myung

    2007-01-01

    By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well

  6. Grassmannian geometry of scattering amplitudes

    CERN Document Server

    Arkani-Hamed, Nima; Cachazo, Freddy; Goncharov, Alexander; Postnikov, Alexander; Trnka, Jaroslav

    2016-01-01

    Outlining a revolutionary reformulation of the foundations of perturbative quantum field theory, this book is a self-contained and authoritative analysis of the application of this new formulation to the case of planar, maximally supersymmetric Yang–Mills theory. The book begins by deriving connections between scattering amplitudes and Grassmannian geometry from first principles before introducing novel physical and mathematical ideas in a systematic manner accessible to both physicists and mathematicians. The principle players in this process are on-shell functions which are closely related to certain sub-strata of Grassmannian manifolds called positroids - in terms of which the classification of on-shell functions and their relations becomes combinatorially manifest. This is an essential introduction to the geometry and combinatorics of the positroid stratification of the Grassmannian and an ideal text for advanced students and researchers working in the areas of field theory, high energy physics, and the...

  7. Determination of backward pion nucleon scattering amplitudes

    International Nuclear Information System (INIS)

    Pietarinen, E.

    1978-04-01

    Backward C(sup(+-))πN amplitudes are determined from πN→Nπ and NantiN→2π differential cross sections in such a way that they are consistent with the analyticity properties and information of the unphysical ππ→NantiN amplitudes. Combining the result with forward C(sup(+-)) amplitudes positive and negative parity resonances are extracted. An error analysis of the amplitudes is performed. (author)

  8. Pulse-shaping strategies in short-pulse fiber amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Schimpf, Damian Nikolaus

    2010-02-09

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  9. Pulse-shaping strategies in short-pulse fiber amplifiers

    International Nuclear Information System (INIS)

    Schimpf, Damian Nikolaus

    2010-01-01

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  10. a case report of premenarchial transverse vaginal septum

    African Journals Online (AJOL)

    Premenarchial Transverse vaginal septum is a benign condition. The septum may be ... She had surgical resection of the vaginal septum and a vaginal stent was left in-situ to ... suggested to prevent stenosis described the use of high pressure ...

  11. Prevalence of Vaginal Candidiasis among Pregnant Women with ...

    African Journals Online (AJOL)

    BACKGROUND: Pregnancy represents a risk factor in the occurrence of vaginal candidiasis. OBJECTIVES: To determine the prevalence and clinical features associated with abnormal vaginal discharge and C. albicans infection in pregnant women. METHODS: High vaginal swab samples and data on epidemiological ...

  12. Prepubertal vaginal discharge: Vaginoscopy to rule out foreign body.

    Science.gov (United States)

    Ekinci, Saniye; Karnak, İbrahim; Tanyel, Feridun Cahit; Çiftçi, Arbay Özden

    2016-01-01

    Medical records of all prepubertal patients who underwent vaginoscopy to rule out vaginal foreign body between 2004 and 2013 were reviewed retrospectively. All patients were evaluated by pediatricians prior to surgical consultation. Vaginoscopy is performed in the operating room under general anesthesia. During the study period, 20 girls with persistent vaginal discharge with a mean age of 6.8 years (1-13 years) underwent vaginoscopy to rule out vaginal foreign body. Six patients had bloody vaginal discharge and 4 had recurrent vaginal bleeding lasting for more than one month. Ten patients had purulent vaginal discharge lasting for 1-7 months. None of vaginal cultures revealed pathological bacteria or candida species. Preoperative imaging techniques revealed vaginal foreign body in one patient only. Vaginoscopy demonstrated vaginal foreign bodies in four patients. Foreign bodies were grass inflorescence, safety pin and undefined brownish particles (n=2), which may be pieces of toilet paper or feces. There was no complication related to vaginoscopy and removal of foreign body. Hymen integrity was preserved in all patients. Persistent or recurrent vaginal discharge in prepubertal girls should raise the suspect of vaginal foreign body. Continuous flow vaginoscopy is mandatory to detect and remove any vaginal foreign body. Early diagnosis would prevent complications secondary to long-standing foreign bodies.

  13. Nanosecond bipolar pulse generators for bioelectrics.

    Science.gov (United States)

    Xiao, Shu; Zhou, Chunrong; Yang, Enbo; Rajulapati, Sambasiva R

    2018-04-26

    Biological effects caused by a nanosecond pulse, such as cell membrane permeabilization, peripheral nerve excitation and cell blebbing, can be reduced or cancelled by applying another pulse of reversed polarity. Depending on the degree of cancellation, the pulse interval of these two pulses can be as long as dozens of microseconds. The cancellation effect diminishes as the pulse duration increases. To study the cancellation effect and potentially utilize it in electrotherapy, nanosecond bipolar pulse generators must be made available. An overview of the generators is given in this paper. A pulse forming line (PFL) that is matched at one end and shorted at the other end allows a bipolar pulse to be produced, but no delay can be inserted between the phases. Another generator employs a combination of a resistor, an inductor and a capacitor to form an RLC resonant circuit so that a bipolar pulse with a decaying magnitude can be generated. A third generator is a converter, which converts an existing unipolar pulse to a bipolar pulse. This is done by inserting an inductor in a transmission line. The first phase of the bipolar pulse is provided by the unipolar pulse's rising phase. The second phase is formed during the fall time of the unipolar pulse, when the inductor, which was previously charged during the flat part of the unipolar pulse, discharges its current to the load. The fourth type of generator uses multiple MOSFET switches stacked to turn on a pre-charged, bipolar RC network. This approach is the most flexible in that it can generate multiphasic pulses that have different amplitudes, delays, and durations. However, it may not be suitable for producing short nanosecond pulses (<100 ns), whereas the PFL approach and the RLC approach with gas switches are used for this range. Thus, each generator has its own advantages and applicable range. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. ACR Appropriateness Criteria® First Trimester Vaginal Bleeding.

    Science.gov (United States)

    Brown, Douglas L; Packard, Ann; Maturen, Katherine E; Deshmukh, Sandeep Prakash; Dudiak, Kika M; Henrichsen, Tara L; Meyer, Benjamin J; Poder, Liina; Sadowski, Elizabeth A; Shipp, Thomas D; Simpson, Lynn; Weber, Therese M; Zelop, Carolyn M; Glanc, Phyllis

    2018-05-01

    Vaginal bleeding is not uncommon in the first trimester of pregnancy. The majority of such patients will have a normal intrauterine pregnancy (IUP), a nonviable IUP, or an ectopic pregnancy. Ultrasound (US) is the primary imaging modality in evaluation of these patients. US, along with clinical observations and serum human chorionic gonadotropin levels, can usually distinguish these causes. Although it is important to diagnose ectopic pregnancies and nonviable IUPs, one should also guard against injury to normal pregnancies due to inappropriate treatment with methotrexate or surgical intervention. Less common causes of first trimester vaginal bleeding include gestational trophoblastic disease and arteriovenous malformations. Pulsed methods of Doppler US should generally be avoided in the first trimester when there is a normal, or a potentially normal, IUP. Once a normal IUP has been excluded, Doppler US may be useful when other diagnoses such as retained products of conception or arteriovenous malformations are suspected. MRI may occasionally be helpful as a problem-solving tool. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  15. Pulse height model for deuterated scintillation detectors

    International Nuclear Information System (INIS)

    Wang, Haitang; Enqvist, Andreas

    2015-01-01

    An analytical model of light pulse height distribution for finite deuterated scintillation detectors is created using the impulse approximation. Particularly, the energy distribution of a scattered neutron is calculated based on an existing collision probability scheme for general cylindrical shaped detectors considering double differential cross-sections. The light pulse height distribution is analytically and numerically calculated by convoluting collision sequences with the light output function for an EJ-315 detector from our measurements completed at Ohio University. The model provides a good description of collision histories capturing transferred neutron energy in deuterium-based scintillation materials. The resulting light pulse height distribution details pulse compositions and their corresponding contributions. It shows that probabilities of neutron collision with carbon and deuterium nuclei are comparable, however the light pulse amplitude due to collisions with carbon nuclei is small and mainly located at the lower region of the light pulse distribution axis. The model can explore those neutron interaction events that generate pulses near or below a threshold that would be imposed in measurements. A comparison is made between the light pulse height distributions given by the analytical model and measurements. It reveals a significant probability of a neutron generating a small light pulse due to collisions with carbon nuclei when compared to larger light pulse generated by collisions involving deuterium nuclei. This model is beneficial to understand responses of scintillation materials and pulse compositions, as well as nuclei information extraction from recorded pulses.

  16. Vaginal vault drainage after complicated single-port access laparoscopic-assisted vaginal hysterectomy

    Directory of Open Access Journals (Sweden)

    Soo-Jeong Lee

    2017-05-01

    Conclusion: Vaginal vault drainage could be a safe alternative that allows for the management of postoperative morbidity and retains the advantages of minimally invasive surgery after complicated SPA-LAVH.

  17. Lactobacilli Dominance and Vaginal pH: Why is the Human Vaginal Microbiome Unique?

    Directory of Open Access Journals (Sweden)

    Elizabeth A. Miller

    2016-12-01

    Full Text Available The human vaginal microbiome is dominated by bacteria from the genus Lactobacillus, which create an acidic environment thought to protect women against sexually transmitted pathogens and opportunistic infections. Strikingly, lactobacilli dominance appears to be unique to humans; while the relative abundance of lactobacilli in the human vagina is typically >70%, in other mammals lactobacilli rarely comprise more than 1% of vaginal microbiota. Several hypotheses have been proposed to explain humans' unique vaginal microbiota, including humans' distinct reproductive physiology, high risk of STDs, and high risk of microbial complications linked to pregnancy and birth. Here, we test these hypotheses using comparative data on vaginal pH and the relative abundance of lactobacilli in 26 mammalian species and 50 studies (N=21 mammals for pH and 14 mammals for lactobacilli abundance. We found that non-human mammals, like humans, exhibit the lowest vaginal pH during the period of highest estrogen. However, the vaginal pH of non-human mammals is never as low as is typical for humans (median vaginal pH in humans = 4.5; range of pH across all 21 non-human mammals = 5.4 to 7.8. Contrary to disease and obstetric risk hypotheses, we found no significant relationship between vaginal pH or lactobacilli abundance and multiple metrics of STD or birth injury risk (P-values ranged from 0.13 to 0.99. Given the lack of evidence for these hypotheses, we discuss two alternative explanations: the common function hypothesis and a novel hypothesis related to the diet of agricultural humans. Specifically, with regard to diet we propose that high levels of starch in human diets have led to increased levels of glycogen in the vaginal tract, which, in turn, promotes the proliferation of lactobacilli. If true, human diet may have paved the way for a novel, protective microbiome in human vaginal tracts. Overall, our results highlight the need for continuing research on non

  18. Dynamic clinical measurements of voluntary vaginal contractions and autonomic vaginal reflexes.

    Science.gov (United States)

    Broens, Paul M A; Spoelstra, Symen K; Weijmar Schultz, Willibrord C M

    2014-12-01

    The vaginal canal is an active and responsive canal. It has pressure variations along its length and shows reflex activity. At present, the prevailing idea is that the vaginal canal does not have a sphincter mechanism. It is hypothesized that an active vaginal muscular mechanism exists and might be involved in the pathophysiology of genito-pelvic pain/penetration disorder. The aim of this study was to detect the presence of a canalicular vaginal "sphincter mechanism" by measuring intravaginal pressure at different levels of the vaginal canal during voluntary pelvic floor contractions and during induced reflexive contractions. Sixteen nulliparous women, without sexual dysfunction and pelvic floor trauma, were included in the study. High-resolution solid-state circumferential catheters were used to measure intravaginal pressures and vaginal contractions at different levels in the vaginal canal. Voluntary intravaginal pressure measurements were performed in the left lateral recumbent position only, while reflexive intravaginal pressure measurements during slow inflation of a vaginal balloon were performed in the left lateral recumbent position and in the sitting position. Intravaginal pressures and vaginal contractions were the main outcome measures. In addition, a general demographic and medical history questionnaire was administered to gain insight into the characteristics of the study population. Fifteen out of the sixteen women had deep and superficial vaginal high-pressure zones. In one woman, no superficial high-pressure zone was found. The basal and maximum pressures, as well as the duration of the autonomic reflexive contractions significantly exceeded the pressures and the duration of the voluntary contractions. There were no significant differences between the reflexive measurements obtained in the left lateral recumbent and the sitting position. The two high-pressure zones found in this study, as a result of voluntary contractions and, even more pronounced

  19. assisted vaginal hysterectomy versus abdominal hysterectomy on ...

    African Journals Online (AJOL)

    minimal postoperative discomfort and less need for ... the feasibility of registrar training in laparoscopic-assisted vaginal hysterectomy (LAVH), and to investigate the impact of laparoscopy in changing the route of hysterectomy in women assessed as being unsuitable for ... All patients received prophylactic antibiotics during.

  20. Assessment of vaginal atrophy: a review

    NARCIS (Netherlands)

    Weber, M. A.; Limpens, J.; Roovers, J. P. W. R.

    2015-01-01

    The aim of this study is to provide an evidence-based definition of vaginal atrophy (VA) and present an overview of subjective and objective measurements of VA applicable in clinical practice and research. A systematic literature search was performed in MEDLINE and EMBASE to identify studies

  1. Vaginal Lacerations from Consensual Intercourse in Adolescents

    Science.gov (United States)

    Frioux, Sarah M.; Blinman, Thane; Christian, Cindy W.

    2011-01-01

    Objective: (1) To describe lacerations of the vaginal fornices, an injury known to be associated with consensual sexual intercourse, including known complications and treatment course, (2) to contrast these injuries with injuries sustained during sexual assault, and (3) to discuss the assessment of adolescent patients for sexual injuries. Methods:…

  2. The vaginal microflora in relation to gingivitis

    Science.gov (United States)

    2009-01-01

    Background Gingivitis has been linked to adverse pregnancy outcome (APO). Bacterial vaginosis (BV) has been associated with APO. We assessed if bacterial counts in BV is associated with gingivitis suggesting a systemic infectious susceptibilty. Methods Vaginal samples were collected from 180 women (mean age 29.4 years, SD ± 6.8, range: 18 to 46), and at least six months after delivery, and assessed by semi-quantitative DNA-DNA checkerboard hybridization assay (74 bacterial species). BV was defined by Gram stain (Nugent criteria). Gingivitis was defined as bleeding on probing at ≥ 20% of tooth sites. Results A Nugent score of 0–3 (normal vaginal microflora) was found in 83 women (46.1%), and a score of > 7 (BV) in 49 women (27.2%). Gingivitis was diagnosed in 114 women (63.3%). Women with a diagnosis of BV were more likely to have gingivitis (p = 0.01). Independent of gingival conditions, vaginal bacterial counts were higher (p gingivitis had higher counts of Prevotella bivia (p 1.0 × 104 cells) and a diagnosis of gingivitis was 3.9 for P. bivia (95% CI 1.5–5.7, p gingivitis in comparison to women with BV but not gingivitis. P. bivia and P. disiens may be of specific significance in a relationship between vaginal and gingival infections. PMID:19161595

  3. [Severe vaginal discharge following rectal surgery

    NARCIS (Netherlands)

    Burg, L.C.; Bremers, A.J.A.; Heesakkers, J.P.; Kluivers, K.B.

    2018-01-01

    BACKGROUND: Almost 50% of women who have had rectal surgery subsequently develop vaginal discharge. Due to the recurrent and unexpected nature of this heavy discharge, they often experience it as very distressing. Many of these women undergo extensive diagnostic tests that are mainly focused on

  4. An isolated vaginal metastasis from rectal cancer

    Directory of Open Access Journals (Sweden)

    Ai Sadatomo

    2016-02-01

    Conclusion: We should keep the vagina within the field of view of pelvic MRI, which is one of the preoperative diagnostic tools for colorectal cancer. If female patients show gynecological symptoms, gynecological examination should be recommended. Isolated vaginal metastases are an indication for surgical resection, and adjuvant chemotherapy is also recommended.

  5. Predictors of vaginal delivery in nulliparous mothers

    African Journals Online (AJOL)

    physical characteristics such as height and weight, events in labor and mode of ... maternal BMI, fetal head engagement and normal range of fetal birth weight were .... gestational age at booking, height, weight, fetal ... study due to: Hypertensive disorders of pregnancy ... vaginal delivery compared with overweight or obese.

  6. Bioadhesive Controlled Release Clotrimazole Vaginal Tablets | Bhat ...

    African Journals Online (AJOL)

    Conclusion: This study indicates the possible use of suitable mixtures of natural and semi-synthetic cellulosic polymers for the preparation of clotrimazole mucoadhesive tablets for application as a vaginal controlled delivery system. Keywords: Clotrimazole, Swelling, Cellulosic polymers, Guar gum, Bioadhesion, Release ...

  7. Vaginal foreign body causing recurrent discharge and vaginal stenosis--a case report.

    Science.gov (United States)

    Gurung, Geeta; Rana, Ashma; Amatya, Archana

    2007-06-01

    Chronic vaginal discharge in children and adolescents is a common gynaecological complaint which is often resistant to antibiotic treatment. We present a 14 years old, premenarcheal girl who presented to us with the complaints of recurrent, foul smelling purulent occasionally blood stained vaginal discharge for eight years, where a foreign body in the upper vagina was found after releasing a dense adhesion of the lower vagina which was unable to detect by pelvic ultrasound.

  8. The device for measuring amplitude spectra of ionizing irradiation

    International Nuclear Information System (INIS)

    Polyak, Yu.V.; Nebesnyj, A.F.

    1996-01-01

    The front-end electronic device for measuring of amplitude spectra of ionizing radiation have been made. The device have connection interface with the ionizing radiation detector, the pulse former, adapter, memory, electron ray tube with diode, supply unit and the regime setting unit of the work of electron ray tube. There are linear transmission scheme, level discriminator, pulse series - channel code converter, dividing capacitor in the device. Dynode of electron ray tube has been made in the form of rack or pads installed in the line parallel to axis of vertical scanning and electrically joined with each other. The distance between next tooth of rack or pads is Δy≥0,5 d, where d - diameter of focused electron beam of electron ray tube. The output of pulse former is joined with level discriminator and the first entrance of linear transmission scheme. The output of linear transmission scheme is joined with the entrance of pulse delay scheme, and the second entrance is joined with the first output of level discriminator. The output of pulse delay scheme is joined with Y-deflecting plate of electron ray tube. The first and the second entrance of pulse series - channel code converter are joined correspondingly with the output of adapter and the second output of level discriminator, and its output - with the entrance of memory unit. The first pin of loading resistor is joined through dividing capacitor with the entrance of adapter, its second pin - with the anode output nearest to dynode of electron ray tube. (E.V.Kh.)

  9. Universal pulse generator with a nanosecond fast responce

    International Nuclear Information System (INIS)

    Basiladze, S.G.; Nguen Kuang Min'.

    1977-01-01

    A pulse generator with nanosecond action is described; it is mainly designed for testing and tuning fast electronic devices operating with pulses in the N/1/M standard. The generator is principally based on integral circuits and has wide functional potentialities: it includes a main-pulse channel, a delayed-pulse channel, and an overall output, which sums up these pulses; in addition to the logic pulse outputs it includes a linear pulse output with an amplitude smoothly regulated in the range from 0.3 to 6.0 V; it can operate in the self-oscillation mode, in the pulse series formation mode, in the starting mode, and in the single-start mode. Two generators are placed in a double-width CAMAC cell. The generation frequency is from 3 Hz to 75 MHz, pulse duration from 8 to 320 ns, and pulse front duration 2 ns

  10. In Vitro Activity of Tea Tree Oil Vaginal Suppositories against Candida spp. and Probiotic Vaginal Microbiota.

    Science.gov (United States)

    Di Vito, Maura; Mattarelli, Paola; Modesto, Monica; Girolamo, Antonietta; Ballardini, Milva; Tamburro, Annunziata; Meledandri, Marcello; Mondello, Francesca

    2015-10-01

    The aim of this work is to evaluate the in vitro microbicidal activity of vaginal suppositories (VS) containing tea tree oil (TTO-VS) towards Candida spp. and vaginal probiotics. A total of 20 Candida spp. strains, taken from patients with vaginitis and from an established type collection, including reference strains, were analysed by using the CLSI microdilution method. To study the action of VS towards the beneficial vaginal microbiota, the sensitivity of Bifidobacterium animalis subsp. lactis (DSM 10140) and Lactobacillus spp. (Lactobacillus casei R-215 and Lactobacillus acidophilus R-52) was tested. Both TTO-VS and TTO showed fungicidal activity against all strains of Candida spp. whereas placebo-VS or the Aloe gel used as controls were ineffective. The study of fractional fungicidal concentrations (FFC) showed synergistic interaction with the association between Amphotericin B and TTO (0.25 to 0.08 µg/ml, respectively) against Candida albicans. Instead, the probiotics were only affected by TTO concentration ≥ 4% v/v, while, at concentrations vaginal microbiota. In vivo studies are needed to confirm the efficacy to prevent acute or recurrent vaginal candidiasis. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Vaginally-Assisted Laparoscopic Hysterosacropexy for Advanced Utero-Vaginal Prolapse: A Series of 32 Cases

    Directory of Open Access Journals (Sweden)

    Elvira Brătilă V.

    2014-05-01

    Full Text Available Advanced utero-vaginal prolapse is a frequent condition in the aging female population and several strategies aimed at its treatment have been developed. In order to demonstrate the importance of using the vaginal route in assistance to laparoscopic hysterosacropexy, a retrospective case series was designed, comparing thirty-two patients diagnosed with stage III-IV uterovaginal prolapse according to the POP-Q system. The patients were treated between 2006-2011 using one of two methods of hysterosacropexy: vaginally assisted laparoscopic hysterosacropexy (VALHS in 18 cases and total laparoscopic hysterosacropexy (LHS in 14 cases. The choice of method was based on the primary mechanism of central compartment prolapse. The total operative time, the time required for mesh fixation at the cervix and sacrum, the cure rate of prolapse and the rate of re-operation for prolapse were statistically analyzed for both LHS and VALHS and compared between these two procedures by Student T-Test. The main outcome parameters were related to the operative method. The total operative time proved to be equal for both procedures, although the time necessary to attach the mesh to the cervical ring was shorter in VALHS. Therefore, the combination of the vaginal and laparoscopic routes yields a minimally invasive variant of sacropexy with as short an operative time as possible. The vaginal route offers a safe alternative for suturing the mesh and treating concurrent vaginal wall prolapse, while laparoscopy reduces the inherent risks of open abdominal surgery.

  12. Evaluation of dynamic range for LLNL streak cameras using high contrast pulsed and pulse podiatry on the Nova laser system

    International Nuclear Information System (INIS)

    Richards, J.B.; Weiland, T.L.; Prior, J.A.

    1990-01-01

    This paper reports on a standard LLNL streak camera that has been used to analyze high contrast pulses on the Nova laser facility. These pulses have a plateau at their leading edge (foot) with an amplitude which is approximately 1% of the maximum pulse height. Relying on other features of the pulses and on signal multiplexing, we were able to determine how accurately the foot amplitude was being represented by the camera. Results indicate that the useful single channel dynamic range of the instrument approaches 100:1

  13. Generation of programmable temporal pulse shape and applications in micromachining

    Science.gov (United States)

    Peng, X.; Jordens, B.; Hooper, A.; Baird, B. W.; Ren, W.; Xu, L.; Sun, L.

    2009-02-01

    In this paper we presented a pulse shaping technique on regular solid-state lasers and the application in semiconductor micromachining. With a conventional Q-switched laser, all of the parameters can be adjusted over only limited ranges, especially the pulse width and pulse shape. However, some laser link processes using traditional laser pulses with pulse widths of a few nanoseconds to a few tens of nanoseconds tend to over-crater in thicker overlying passivation layers and thereby cause IC reliability problems. Use of a laser pulse with a special shape and a fast leading edge, such as tailored pulse, is one technique for controlling link processing. The pulse shaping technique is based on light-loop controlled optical modulation to shape conventional Q-switched solid-state lasers. One advantage of the pulse shaping technique is to provide a tailored pulse shape that can be programmed to have more than one amplitude value. Moreover, it has the capability of providing programmable tailored pulse shapes with discrete amplitude and time duration components. In addition, it provides fast rising and fall time of each pulse at fairly high repetition rate at 355nm with good beam quality. The regular-to-shaped efficiency is up to 50%. We conclude with a discussion of current results for laser processing of semiconductor memory link structures using programmable temporal pulse shapes. The processing experiments showed promising results with shaped pulse.

  14. Optical UWB pulse generator using an N tap microwave photonic filter and phase inversion adaptable to different pulse modulation formats.

    Science.gov (United States)

    Bolea, Mario; Mora, José; Ortega, Beatriz; Capmany, José

    2009-03-30

    We propose theoretically and demonstrate experimentally an optical architecture for flexible Ultra-Wideband pulse generation. It is based on an N-tap reconfigurable microwave photonic filter fed by a laser array by using phase inversion in a Mach-Zehnder modulator. Since a large number of positive and negative coefficients can be easily implemented, UWB pulses fitted to the FCC mask requirements can be generated. As an example, a four tap pulse generator is experimentally demonstrated which complies with the FCC regulation. The proposed pulse generator allows different pulse modulation formats since the amplitude, polarity and time delay of generated pulse is controlled.

  15. Group B streptococcus exploits vaginal epithelial exfoliation for ascending infection.

    Science.gov (United States)

    Vornhagen, Jay; Armistead, Blair; Santana-Ufret, Verónica; Gendrin, Claire; Merillat, Sean; Coleman, Michelle; Quach, Phoenicia; Boldenow, Erica; Alishetti, Varchita; Leonhard-Melief, Christina; Ngo, Lisa Y; Whidbey, Christopher; Doran, Kelly S; Curtis, Chad; Waldorf, Kristina M Adams; Nance, Elizabeth; Rajagopal, Lakshmi

    2018-04-09

    Thirteen percent of pregnancies result in preterm birth or stillbirth, accounting for fifteen million preterm births and three and a half million deaths annually. A significant cause of these adverse pregnancy outcomes is in utero infection by vaginal microorganisms. To establish an in utero infection, vaginal microbes enter the uterus by ascending infection; however, the mechanisms by which this occurs are unknown. Using both in vitro and murine models of vaginal colonization and ascending infection, we demonstrate how a vaginal microbe, group B streptococcus (GBS), which is frequently associated with adverse pregnancy outcomes, uses vaginal exfoliation for ascending infection. GBS induces vaginal epithelial exfoliation by activation of integrin and β-catenin signaling. However, exfoliation did not diminish GBS vaginal colonization as reported for other vaginal microbes. Rather, vaginal exfoliation increased bacterial dissemination and ascending GBS infection, and abrogation of exfoliation reduced ascending infection and improved pregnancy outcomes. Thus, for some vaginal bacteria, exfoliation promotes ascending infection rather than preventing colonization. Our study provides insight into mechanisms of ascending infection by vaginal microbes.

  16. Atrophic Vaginitis in Breast Cancer Survivors: A Difficult Survivorship Issue

    Directory of Open Access Journals (Sweden)

    Joanne Lester

    2015-03-01

    Full Text Available Management of breast cancer includes systematic therapies including chemotherapy and endocrine therapy can lead to a variety of symptoms that can impair the quality of life of many breast cancer survivors. Atrophic vaginitis, caused by decreased levels of circulating estrogen to urinary and vaginal receptors, is commonly experienced by this group. Chemotherapy induced ovarian failure and endocrine therapies including aromatase inhibitors and selective estrogen receptor modulators can trigger the onset of atrophic vaginitis or exacerbate existing symptoms. Symptoms of atrophic vaginitis include vaginal dryness, dyspareunia, and irritation of genital skin, pruritus, burning, vaginal discharge, and soreness. The diagnosis of atrophic vaginitis is confirmed through patient-reported symptoms and gynecological examination of external structures, introitus, and vaginal mucosa. Lifestyle modifications can be helpful but are usually insufficient to significantly improve symptoms. Non-hormonal vaginal therapies may provide additional relief by increasing vaginal moisture and fluid. Systemic estrogen therapy is contraindicated in breast cancer survivors. Continued investigations of various treatments for atrophic vaginitis are necessary. Local estrogen-based therapies, DHEA, testosterone, and pH-balanced gels continue to be evaluated in ongoing studies. Definitive results are needed pertaining to the safety of topical estrogens in breast cancer survivors.

  17. Vaginal Masses: Magnetic Resonance Imaging Features with Pathologic Correlation

    International Nuclear Information System (INIS)

    Elsayes, K.M.; Narra, V.R.; Dillman, J.R.; Velcheti, V.; Hameed, O.; Tongdee, R.; Menias, C.O.

    2007-01-01

    The detection of vaginal lesions has increased with the expanding use of cross-sectional imaging. Magnetic resonance imaging (MRI) - with its high-contrast resolution and multiplanar capabilities - is often useful for characterizing vaginal masses. Vaginal masses can be classified as congenital, inflammatory, cystic (benign), and neoplastic (benign or malignant) in etiology. Recognition of the typical MR imaging features of such lesions is important because it often determines the treatment approach and may obviate surgery. Finally, vaginal MR imaging can be used to evaluate post-treatment changes related to previous surgery and radiation therapy. In this article, we will review pertinent vaginal anatomy, vaginal and pelvic MRI technique, and the MRI features of a variety of vaginal lesions with pathological correlation

  18. Twenty-channel high-voltage pulse generators

    International Nuclear Information System (INIS)

    Anan'in, P.S.; Kashirin, A.P.

    1980-01-01

    A 20-channel high-voltage pulse generator operating with a mismatched load is described. The generator contains shaping lines 20 m long made of coaxial cable, a trigatron-type discharged, and isolating plates. The channel characteristic impedance is 50 Ohm. The maximum pulse amplitude is up to 15 kV on a high-resistance load and 7.5 kV on a matched one. The pulse duration is 100 ns at a pulse rise time of 12 ns, the delay introduced by the generator is 200 +-2.5 ns. Provision is made in the control circuit for compensation of the shaped pulse and separation of a pulse reflected from the load. The reflected pulse shape and amplitude characterize load parameters. Generator tests proved its high operational reliability (after 10 5 operations no significant changes in generator performances have been observed). The generator is intended for filmless data output from spark chambers

  19. Nonresonant Multiple-Pulse Control of Molecular Motions in Liquid

    Directory of Open Access Journals (Sweden)

    Nikiforov V.G.

    2015-01-01

    Full Text Available We propose the implementation of the multiple-pulse excitation for manipulation of the molecular contributions to the optically-heterodyne-detected optical-Kerr-effect. The key parameters controlling the specificity of the multiple-pulse excitation scenarios are the pulses durations, the delays between pulses, the relation between the pump pulses amplitudes and the pulses polarizations. We model the high-order optical responses and consider some principles of the scenarios construction. We show that it is possible to adjust the excitation scenario in such a way that the some responses can be removed from detected signal along with the enhancement of the interested response amplitude. The theoretical analysis and first experimental data reveal that the multiple-pulse excitation technique can be useful for the selective spectroscopy of the molecular vibrations and rotations in liquid.

  20. CAMAC differential pulse discriminator-counter

    International Nuclear Information System (INIS)

    Tselikov, N.V.

    1987-01-01

    Differential pulse discriminator-counter for Moessbauer spectrometer is described. Input pulse setting into the channel is performed according to the following algorithm: the pulse is transmitted to the channel depending on the fact whether the preceding pulse has got to the discrimination window or not. The circuit does not contain delay lines, taking into account the delay of a signal from the upper level discriminator in relation to the lower level discriminator signal, which is connected with input pulse rise finite time, which in turn allows one to reduce the discriminator dead time up to the operation time of threshold circuits. The pulse counting rate is 150 MHz, input signal amplitude is ±3 V, dead time is 6 ns, delay time from input to output is 14 ns. The unit is made in CAMAC system

  1. A novel time-to-pulse height converter for fast-neutron time-of-flight techniques; Nouveau convertisseur temps-amplitude d'impulsions pour les mesures du temps de vol des neutrons rapides; Novyj vremya-amplitudnyj preobrazovatel' impul'sov dlya izmereniya vremeni proleta bystrykh nejtronov; Nuevo convertidor tiempo-altura de impulsos para tecnicas de tiempo de vuelo de neutrones rapidos

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, J [Physikalisches Staatsinstitut, Hamburg, Federal Republic of Germany (Germany)

    1962-04-15

    An electronic time-to-pulse height converter is described which uses a multiplicative method instead of the usual one of adding overlapping pulses. This is achieved by a coincidence of a linear sawtooth and a sharply clipped needle-pulse. The sawtooth is fed to the grid of a beam-deflecting tube (E80T) and the needle-pulse is applied to the deflecting plates and opens the tube only during a time-interval of about 5.10{sup -9} s. The plate gets a charge proportional to the time-difference between the start of the sawtooth and the needle pulse. The plate-pulse is stretched and amplified and its height represents a measurement of the time-difference. With this method we got a time resolution of 2{tau} = 7 x 10{sup -12}s with artificial pulses, 2{tau} = 3 x 10{sup -10}s with Co{sup 60} {gamma}-coincidences by using NE 102 plastic crystals and 2{tau} = 1.4 x 10{sup -9} s with 511-keV {gamma}-coincidences using NaI(Te) crystals. The method was also used with pulsed beam techniques. In this case we got from the pulsing RF an 8-Mc, sharply-peaked pulse-sequence, which was fed to the E80T plates. We had a time-resolution of 2{tau} = 1.1 x 10{sup -9} s with 4-MeV neutrons using plastic crystals 0.7 in long. Normally the region of linear response was 30 ns but it was possible to go up to 120 ns. (author) [French] L'auteur decrit un convertisseur electronique temps en amplitude d'impulsions fonctionnant d'apres une methode de multiplication au lieu de la methode habituelle qui consiste a ajouter des impulsions qui se chevauchent. On fait coincider une impulsion lineaire en dents de scie avec une impulsion en forme d'aiguille fortement ecretee. L'impulsion en dents de scie est envoyee sur la grille d'un tube a faisceaux electroniques diriges (E80T) ; et l'impulsion en forme d'aiguille est appliquee aux plaques de deflexion et n'ouvre le tube que pendant un intervalle de temps d'environ 5 {center_dot} 10{sup -9} s. La plaque recoit une charge proportionnelle a la difference de

  2. Current pulse generator of an induction accelerator electromagnet

    International Nuclear Information System (INIS)

    Baginskij, B.A.; Makarevich, V.N.; Shtejn, M.M.

    1987-01-01

    Thyristor generator forming in betatron electromagnet coil sinusoidal and quasisinusoidal current unipolar pulses, the field being deforced at the beginning of acceleration cycle, and with the pulse flat top in the cycle end, is described. The current amplitude is controlled by pulse-phase method. The current pulse time shift permitted to decrease the loss rate in the accumulating capacitor. The generator is used in systems with 1-10 ms pulse duration, electromagnet magnetic field maximal energy - 45-450 J, the voltage amplitude in the coil 960-1500 V and amplitude of the current passing the coil 100-500 A, the repetition frequency being 50-200 Hz. In particular, the generator is used to supply betatrons designed for defectoscopy in nonstationary conditions, the accelerated electron energy being 4, 6, 8 and 15 MeV

  3. To Pack or Not to Pack? A Randomized Trial of Vaginal Packing After Vaginal Reconstructive Surgery.

    Science.gov (United States)

    Westermann, Lauren B; Crisp, Catrina C; Oakley, Susan H; Mazloomdoost, Donna; Kleeman, Steven D; Benbouajili, Janine M; Ghodsi, Vivian; Pauls, Rachel N

    2016-01-01

    Placement of vaginal packing after pelvic reconstructive surgery is common; however, little evidence exists to support the practice. Furthermore, patients have reported discomfort from the packs. We describe pain and satisfaction in women treated with and without vaginal packing. This institutional review board-approved randomized-controlled trial enrolled patients undergoing vaginal hysterectomy with prolapse repairs. The primary outcome was visual analog scales (VASs) for pain on postoperative day 1. Allocation to "packing" ("P") or "no-packing" ("NP") arms occurred intraoperatively at the end of surgery. Visual analog scales regarding pain and satisfaction were completed early on postoperative day 1 before packing removal. Visual analog scale scores for pain, satisfaction, and bother attributable to packing were recorded before discharge. All packing and perineal pads were weighed to calculate a "postoperative vaginal blood loss." Perioperative data were collected from the hospital record. Our sample size estimation required 74 subjects. Ninety-three women were enrolled. After exclusions, 77 were randomized (P, 37; NP, 40). No differences were found in surgical information, hemoglobin levels, or narcotic use between groups. However, "postoperative vaginal blood loss" was greater in packed subjects (P discharge (P, 35.0 vs NP, 40.0; P = 0.43] were not significantly different between treatment arms. Likewise, VAS scores for satisfaction before removal of packing (P, 81.0 vs NP, 90.0; P = 0.08] and before discharge (P, 90.0 vs NP, 90.5; P = 0.60] were not significantly different. Packed patients noted lower nursing verbal pain scores (P = 0.04) and used less ketorolac (P = 0.01). Bother from packing was low overall. Although there was no difference based on VAS, women receiving vaginal packing had lower nursing documented pain and used less ketorolac than packed women. Vaginal packing may provide benefit and can remain part of the surgical practice.

  4. Pulse Width Affects Scalp Sensation of Transcranial Magnetic Stimulation.

    Science.gov (United States)

    Peterchev, Angel V; Luber, Bruce; Westin, Gregory G; Lisanby, Sarah H

    Scalp sensation and pain comprise the most common side effect of transcranial magnetic stimulation (TMS), which can reduce tolerability and complicate experimental blinding. We explored whether changing the width of single TMS pulses affects the quality and tolerability of the resultant somatic sensation. Using a controllable pulse parameter TMS device with a figure-8 coil, single monophasic magnetic pulses inducing electric field with initial phase width of 30, 60, and 120 µs were delivered in 23 healthy volunteers. Resting motor threshold of the right first dorsal interosseus was determined for each pulse width, as reported previously. Subsequently, pulses were delivered over the left dorsolateral prefrontal cortex at each of the three pulse widths at two amplitudes (100% and 120% of the pulse-width-specific motor threshold), with 20 repetitions per condition delivered in random order. After each pulse, subjects rated 0-to-10 visual analog scales for Discomfort, Sharpness, and Strength of the sensation. Briefer TMS pulses with amplitude normalized to the motor threshold were perceived as slightly more uncomfortable than longer pulses (with an average 0.89 point increase on the Discomfort scale for pulse width of 30 µs compared to 120 µs). The sensation of the briefer pulses was felt to be substantially sharper (2.95 points increase for 30 µs compared to 120 µs pulse width), but not stronger than longer pulses. As expected, higher amplitude pulses increased the perceived discomfort and strength, and, to a lesser degree the perceived sharpness. Our findings contradict a previously published hypothesis that briefer TMS pulses are more tolerable. We discovered that the opposite is true, which merits further study as a means of enhancing tolerability in the context of repetitive TMS. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. On the singularities of massive superstring amplitudes

    International Nuclear Information System (INIS)

    Foda, O.

    1987-01-01

    Superstring one-loop amplitudes with massive external states are shown to be in general ill-defined due to internal on-shell propagators. However, we argue that since any massive string state (in the uncompactified theory) has a finite lifetime to decay into massless particles, such amplitudes are not terms in the perturbative expansion of physical S-matrix elements: These can be defined only with massless external states. Consistent massive amplitudes repuire an off-shell formalism. (orig.)

  6. On the singularities of massive superstring amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Foda, O.

    1987-06-04

    Superstring one-loop amplitudes with massive external states are shown to be in general ill-defined due to internal on-shell propagators. However, we argue that since any massive string state (in the uncompactified theory) has a finite lifetime to decay into massless particles, such amplitudes are not terms in the perturbative expansion of physical S-matrix elements: These can be defined only with massless external states. Consistent massive amplitudes repuire an off-shell formalism.

  7. New relations for graviton-matter amplitudes

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    I report on recent progress in finding compact expressions for scattering amplitudes involving gravitons and gluons as well as massive scalar and fermionic matter particles. At tree level the single graviton emission amplitudes may be expressed as linear combination of purely non-gravitational ones. At the one-loop level recent results on all four point Einstein-Yang-Mills amplitudes with at most one opposite helicity state using unitarity methods are reported. 

  8. Analytical properties of multiple production amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Medvedev, B V; Pavlov, V P; Polivanov, M K; Sukhanov, A D [Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Teoreticheskoj i Ehksperimental' noj Fiziki; AN SSSR, Moscow. Matematicheskij Inst.)

    1984-05-01

    Local analytical properties of amplitudes 2..-->..3 and 2..-->..4 are studied. The amplitudes are shown to be analytical functions of total and partial energies at fixed momentum transfers in the neighbourhood of any physical point on the energy shell 14 (for the 2..-->..3 case) and 242 (for the 2..-->..4 case) boundary values are expressed through the amplitudes of real processes.

  9. DVCS amplitude with kinematical twist-3 terms

    International Nuclear Information System (INIS)

    Radyushkin, A.V.; Weiss, C.

    2000-01-01

    The authors compute the amplitude of deeply virtual Compton scattering (DVCS) using the calculus of QCD string operators in coordinate representation. To restore the electromagnetic gauge invariance (transversality) of the twist-2 amplitude they include the operators of twist-3 which appear as total derivatives of twist-2 operators. The results are equivalent to a Wandzura-Wilczek approximation for twist-3 skewed parton distributions. They find that this approximation gives a finite result for the amplitude of a longitudinally polarized virtual photon, while the amplitude for transverse polarization is divergent, i.e., factorization breaks down in this term

  10. Amplitude structure of off-shell processes

    International Nuclear Information System (INIS)

    Fearing, H.W.; Goldstein, G.R.; Moravcsik, M.J.

    1984-01-01

    The structure of M matrices, or scattering amplitudes, and of potentials for off-shell processes is discussed with the objective of determining how one can obtain information on off-shell amplitudes of a process in terms of the physical observables of a larger process in which the first process is embedded. The procedure found is inevitably model dependent, but within a particular model for embedding, a determination of the physically measurable amplitudes of the larger process is able to yield a determination of the off-shell amplitudes of the embedded process

  11. An Alternative Method for Tilecal Signal Detection and Amplitude Estimation

    CERN Document Server

    Sotto-Maior Peralva, B; The ATLAS collaboration; Manhães de Andrade Filho, L; Manoel de Seixas, J

    2011-01-01

    The Barrel Hadronic calorimeter of ATLAS (Tilecal) is a detector used in the reconstruction of hadrons, jets, muons and missing transverse energy from the proton-proton collisions at the Large Hadron Collider (LHC). It comprises 10,000 channels in four readout partitions and each calorimeter cell is made of two readout channels for redundancy. The energy deposited by the particles produced in the collisions is read out by the several readout channels and its value is estimated by an optimal filtering algorithm, which reconstructs the amplitude and the time of the digitized signal pulse sampled every 25 ns. This work deals with signal detection and amplitude estimation for the Tilecal under low signal-to-noise ratio (SNR) conditions. It explores the applicability (at the cell level) of a Matched Filter (MF), which is known to be the optimal signal detector in terms of the SNR. Moreover, it investigates the impact of signal detection when summing both signals from the same cell before estimating the amplitude, ...

  12. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  13. Plasma wave amplitude measurement created by guided laser wakefield

    International Nuclear Information System (INIS)

    Wojda, Franck

    2010-01-01

    The interaction of an intense laser pulse of short duration with a plasma produces a plasma wave with large amplitude in its wake, which is associated with a longitudinal electric field. It can be used to accelerate relativistic electrons injected into the wave to energies in the GeV range over distances of the order of a few centimeters, short compared to acceleration lengths in conventional accelerators. The control of the electron beam characteristics during the acceleration process is fundamental for achieving a usable laser-plasma acceleration stage. The main result of this thesis is the creation and characterization of a plasma wave in a weakly nonlinear regime over a length of several centimeters. Capillary tubes are used to guide the laser beam over these distances, while maintaining a large enough intensity (∼ 10 17 W/cm 2 ). The guided laser beam ionizes the gas in the tube and creates the plasma wave. A diagnostic based on the modification of the laser pulse spectrum was used to determine the amplitude of the plasma wave along the tube. The amplitude of the plasma wave was studied as a function of gas filling pressure, length of the capillary and laser energy. Experimental results are compared; they are in excellent agreement with analytical results and modeling. They show that the electric field associated with the plasma wave is between 1 and 10 GV/m over a length of up to 8 cm. This work has demonstrated the ability to create a controlled plasma wave in a weakly nonlinear regime. (author)

  14. [Morphogenesis of vaginal aplasia. Therapeutic deductions].

    Science.gov (United States)

    Minh, H N; Smadja, A; Belaisch, J

    1985-01-01

    On the basis of the studies of the embryogenesis of the vagina, the authors consider that malformations classically described as being partial aplasia should not be separated from the total absence of the vagina. The important feature is the association of a functioning or non functioning uterus with the absence of the vagina. They believe that it is incorrect to describe the pouch of menstrual retention associated with a functioning uterus as "haematocolpos" and that is not justified to describe the cup-shaped vestibular depression as "hemi-vagina". According to the authors, although vaginal aplasia with a functioning uterus forming a pouch of menstrual retention constitutes an absolute indication for surgery, surgery is not justified in cases of vaginal aplasia with a non functioning uterus. If Frank's method fails in these cases, the patient or the couple should be referred to a sexologist, as women with this anomaly retain a perfect femininity, although unable to conceive.

  15. No. 148-Guidelines for Operative Vaginal Birth.

    Science.gov (United States)

    Cargill, Yvonne M; MacKinnon, Catherine Jane

    2018-02-01

    To provide guidelines for operative vaginal birth in the management of the second stage of labour. Non-operative techniques, episiotomy, and Caesarean section are compared to operative vaginal birth. Reduced fetal and maternal morbidity and mortality. MEDLINE and Cochrane databases were searched using the key words ''vacuum" and "birth" as well as "forceps" and "birth" for literature published in English from january 1970 to June 2004. The level of evidence and quality of rec-ommendations made are described using the Evaluation of Evidence from the Canadian Task Force on the Periodic Health Examination. VALIDATION: The Clinical Practice Obstetrics Committee and Executive and Council of the Society of Obstetricians and Gynaecologists of Canada approved these guidelines. Copyright © 2018. Published by Elsevier Inc.

  16. Broad Ligament Haematoma Following Normal Vaginal Delivery.

    Science.gov (United States)

    Ibrar, Faiza; Awan, Azra Saeed; Fatima, Touseef; Tabassum, Hina

    2017-01-01

    A 37-year-old, patient presented in emergency with history of normal vaginal delivery followed by development of abdominal distention, vomiting, constipation for last 3 days. She was para 4 and had normal vaginal delivery by traditional birth attendant at peripheral hospital 3 days back. Imaging study revealed a heterogeneous complex mass, ascites, pleural effusion, air fluid levels with dilatation gut loops. Based upon pelvic examination by senior gynaecologist in combination with ultrasound; a clinical diagnosis of broad ligament haematoma was made. However, vomiting and abdominal distention raised suspicion of intestinal obstruction. Due to worsening abdominal distention exploratory laparotomy was carried out. It was pseudo colonic obstruction and caecostomy was done. Timely intervention by multidisciplinary approach saved patient life with minimal morbidity.

  17. Biofilms of vaginal Lactobacillus in vitro test.

    Science.gov (United States)

    Wei, Xiao-Yu; Zhang, Rui; Xiao, Bing-Bing; Liao, Qin-Ping

    2017-01-01

    This paper focuses on biofilms of Lactobacillus spp. - a type of normal flora isolated from healthy human vaginas of women of childbearing age; thereupon, it broadens the research scope of investigation of vaginal normal flora. The static slide culture method was adopted to foster biofilms, marked by specific fluorescence staining. Laser scanning confocal and scanning electron microscopy were used to observe the microstructure of the biofilms. Photographs taken from the microstructure were analysed to calculate the density of the biofilms. The body of Lactobacillus spp., though red, turned yellow when interacting with the green extracellular polysaccharides. The structure of the biofilm and aquaporin within the biofilm were imaged. Lactobacillus density increases over time. This study provides convincing evidence that Lactobacillus can form biofilms and grow over time in vitro. This finding establishes an important and necessary condition for selecting proper strains for the pharmaceutics of vaginal ecology.

  18. Spectrum of vaginal discharge in a tertiary care setting.

    Science.gov (United States)

    Sivaranjini, R; Jaisankar, Tj; Thappa, Devinder Mohan; Kumari, Rashmi; Chandrasekhar, Laxmisha; Malathi, M; Parija, Sc; Habeebullah, S

    2013-07-01

    Vaginal discharge is one of the common reasons for gynecological consultation. Many of the causes of vaginitis have a disturbed vaginal microbial ecosystem associated with them. Effective treatment of vaginal discharge requires that the etiologic diagnosis be established and identifying the same offers a precious input to syndromic management and provides an additional strategy for human immunodeficiency virus prevention. The present study was thus carried out to determine the various causes of vaginal discharge in a tertiary care setting. A total of 400 women presenting with vaginal discharge of age between 20 and 50 years, irrespective of marital status were included in this study and women who had used antibiotics or vaginal medication in the previous 14 days and pregnant women were excluded. Of the 400 women with vaginal discharge studied, a diagnosis was established in 303 women. Infectious causes of vaginal discharge were observed in 207 (51.75%) women. Among them, bacterial vaginosis was the most common cause seen in 105 (26.25%) women. The other infections observed were candidiasis alone (61, 15.25%), trichomoniasis alone (12, 3%), mixed infections (22, 5.5%) and mucopurulent cervicitis (7 of the 130 cases looked for, 8.46%). Among the non-infectious causes, 72 (18%) women had physiological vaginal discharge and 13 (3.3%) women had cervical in situ cancers/carcinoma cervix. The pattern of infectious causes of vaginal discharge observed in our study was comparable with the other studies in India. Our study emphasizes the need for including Papanicolaou smear in the algorithm for evaluation of vaginal discharge, as it helps establish the etiology of vaginal discharge reliably and provides a valuable opportunity to screen for cervical malignancies.

  19. Effects of intrauterine contraception on the vaginal microbiota.

    Science.gov (United States)

    Bassis, Christine M; Allsworth, Jenifer E; Wahl, Heather N; Sack, Daniel E; Young, Vincent B; Bell, Jason D

    2017-09-01

    There have been conflicting reports of altered vaginal microbiota and infection susceptibility associated with contraception use. The objectives of this study were to determine if intrauterine contraception altered the vaginal microbiota and to compare the effects of a copper intrauterine device (Cu-IUD) and a levonorgestrel intrauterine system (LNG-IUS) on the vaginal microbiota. DNA was isolated from the vaginal swab samples of 76 women using Cu-IUD (n=36) or LNG-IUS (n=40) collected prior to insertion of intrauterine contraception (baseline) and at 6 months. A third swab from approximately 12 months following insertion was available for 69 (Cu-IUD, n=33; LNG-IUS, n=36) of these women. The V4 region of the bacterial 16S rRNA-encoding gene was amplified from the vaginal swab DNA and sequenced. The 16S rRNA gene sequences were processed and analyzed using the software package mothur to compare the structure and dynamics of the vaginal bacterial communities. The vaginal microbiota from individuals in this study clustered into 3 major vaginal bacterial community types: one dominated by Lactobacillus iners, one dominated by Lactobacillus crispatus and one community type that was not dominated by a single Lactobacillus species. Changes in the vaginal bacterial community composition were not associated with the use of Cu-IUD or LNG-IUS. Additionally, we did not observe a clear difference in vaginal microbiota stability with Cu-IUD versus LNG-IUS use. Although the vaginal microbiota can be highly dynamic, alterations in the community associated with the use of intrauterine contraception (Cu-IUD or LNG-IUS) were not detected over 12 months. We found no evidence that intrauterine contraception (Cu-IUD or LNG-IUS) altered the vaginal microbiota composition. Therefore, the use of intrauterine contraception is unlikely to shift the composition of the vaginal microbiota such that infection susceptibility is altered. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Vaginal Microbiota in Pregnancy: Evaluation Based on Vaginal Flora, Birth Outcome, and Race.

    Science.gov (United States)

    Subramaniam, Akila; Kumar, Ranjit; Cliver, Suzanne P; Zhi, Degui; Szychowski, Jeff M; Abramovici, Adi; Biggio, Joseph R; Lefkowitz, Elliot J; Morrow, Casey; Edwards, Rodney K

    2016-03-01

    This study aims to evaluate vaginal microbiota differences by bacterial vaginosis (BV), birth timing, and race, and to estimate parameters to power future vaginal microbiome studies. Previously, vaginal swabs were collected at 21 to 25 weeks (stored at -80°C), and vaginal smears evaluated for BV (Nugent criteria). In a blinded fashion, 40 samples were selected, creating 8 equal-sized groups stratified by race (black/white), BV (present/absent), and birth timing (preterm/term). Samples were thawed, DNA extracted, and prepared. Polymerase chain reaction (PCR) with primers targeting the 16S rDNA V4 region was used to prepare an amplicon library. PCR products were sequenced and analyzed using quantitative insight into microbial ecology; taxonomy was assigned using ribosomal database program classifier (threshold 0.8) against the modified Greengenes database. After quality control, 97,720 sequences (mean) per sample, single-end 250 base-reads, were analyzed. BV samples had greater microbiota diversity (p Microbiota did not differ by race or birth timing, but there was an association between certain microbial clusters and preterm birth (p = 0.07). To evaluate this difference, 159 patients per group are needed. There are differences in the vaginal microbiota between patients with and without BV. Larger studies should assess the relationship between microbiota composition and preterm birth. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Relationship among vaginal palpation, vaginal squeeze pressure, electromyographic and ultrasonographic variables of female pelvic floor muscles

    Directory of Open Access Journals (Sweden)

    Vanessa S. Pereira

    2014-10-01

    Full Text Available Background: The proper evaluation of the pelvic floor muscles (PFM is essential for choosing the correct treatment. Currently, there is no gold standard for the assessment of female PFM function. Objective: To determine the correlation between vaginal palpation, vaginal squeeze pressure, and electromyographic and ultrasonographic variables of the female PFM. Method: This cross-sectional study evaluated 80 women between 18 and 35 years of age who were nulliparous and had no pelvic floor dysfunction. PFM function was assessed based on digital palpation, vaginal squeeze pressure, electromyographic activity, bilateral diameter of the bulbocavernosus muscles and the amount of bladder neck movement during voluntary PFM contraction using transperineal bi-dimensional ultrasound. The Pearson correlation was used for statistical analysis (p<0.05. Results: There was a strong positive correlation between PFM function and PFM contraction pressure (0.90. In addition, there was a moderate positive correlation between these two variables and PFM electromyographic activity (0.59 and 0.63, respectively and movement of the bladder neck in relation to the pubic symphysis (0.51 and 0.60, respectively. Conclusions: This study showed that there was a correlation between vaginal palpation, vaginal squeeze pressure, and electromyographic and ultrasonographic variables of the PFM in nulliparous women. The strong correlation between digital palpation and PFM contraction pressure indicated that perineometry could easily be replaced by PFM digital palpation in the absence of equipment.

  2. Vaginitis. Reducing the number of refractory cases.

    Science.gov (United States)

    Josey, W E

    1977-09-01

    Therapeutic failure in vaginitis can be minimized if all cases are properly diagnosed and specific therapy is given. Use of wet mounts combined with liberal use of cultures, especially for Corynebacterium vaginale, should result in an accurate diagnosis in over 90% of cases. Treatment of choice for candidiasis is nystatin or miconazole nitrate applied topically. For trichomoniasis, metronidazole should be given orally to both sexual partners. Ampicillin, cephalexin, or cephradine are recommended for C vaginale infection.

  3. Pregnancy and Vaginal Delivery after Sacrohysteropexy

    Directory of Open Access Journals (Sweden)

    Deniz Balsak

    2015-01-01

    Full Text Available Pregnancy and birth after a Pelvic Organ Prolapse (POP surgery is a rare condition and less is known about the method for delivery. A 31-year-old women with gravida 3 para 3 underwent abdominal sacrohysteropexy and transobturatuar tape (TOT procedures for stage III prolapse who delivered via vaginal birth and showed no relapse. Sacrohysteropexy is a good option for women with POP who desire fertility with a long term follow-up period.

  4. Efficacy of oral moxifloxacin for aerobic vaginitis.

    Science.gov (United States)

    Wang, C; Han, C; Geng, N; Fan, A; Wang, Y; Yue, Y; Zhang, H; Xue, F

    2016-01-01

    The purpose of this study was to investigate the therapeutic efficacy of oral moxifloxacin for aerobic vaginitis (AV). We also identified factors that are associated with therapeutic efficacy. This prospective study enrolled general gynecological outpatients at Tianjin Medical University General Hospital between September 2012 and May 2014. Women diagnosed with AV (n = 102) were recruited. All enrolled women were treated with oral moxifloxacin, 400 mg once daily for 6 days (one course). Therapeutic efficacy was evaluated based on microscopic criteria, and cure rates were calculated. Women who were microscopically improved (but not cured) received a second course of therapy. Women classified with microscopic failure were treated using other strategies. Univariate and multivariate logistic regression analysis was used to identify factors that may be associated with a cure after one course of therapy. After one course of therapy, 65.7 % (67/102) of women were cured, 29.4 % (30/102) of women were improved (but not cured), 4.9 % (5/102) of women failed to respond to the therapy. After two courses of therapy, 85.3 % (87/102) of women were cured, 9.8 % (10/102) of women were improved, 4.9 % (5/102) of women failed to respond to the therapy, and clinical improvement was achieved in additional women. In the multivariate logistic regression analysis, women with a baseline vaginal pH value of vaginal pH value of ≥5.0 (OR, 3.503; 95 % CI, 1.278-9.601). Moxifloxacin is an effective therapeutic option for patients with AV. Most women with AV were cured with one course of moxifloxacin. For those with a higher vaginal pH value of ≥5.0 before treatment, two courses of therapy should be considered.

  5. [Saforelle - a new approach to treat vaginitis].

    Science.gov (United States)

    Karamisheva, V; Nachev, A

    2015-01-01

    Infections of the vulva and vagina are one of the most common gynecological diseases. They can be determined by a variety of physical, chemical and biological factors. The main risk factors contributing to vaginitis are aerobic and anaerobic bacterias, fungal and viral infections, and irritants. Subjective complaints are pruritus, vulvar and/or perivulvar erytema and different in volume and characterization discharge. Excepting etiological treatment in most cases it is necessary to use additional agents, for example Saforelle.

  6. A Research Program on the Asymptotic Description of Electromagnetic Pulse Propagation in Spatially Inhomogeneous, Temporally Dispersive, Attenuative Media

    National Research Council Canada - National Science Library

    Oughstun, Kurt E; Cartwright, Natalie A

    2007-01-01

    .... Indeed, previous studies of ultrawideband electromagnetic pulse propagation through dispersive, nonconducting media has shown the existence of a so-called Brillouin precursor whose peak amplitude...

  7. Vaginal rupture and evisceration in a dog.

    Science.gov (United States)

    Prassinos, Nikitas N; Adamama-Moraitou, Katerina K; Ververidis, Haralabos N; Anagnostou, Tilemachos L; Kladakis, Stefanos E

    2010-09-01

    A 1.5-year-old German Shepherd mixed breed dog was admitted with mild haemorrhage from the vulva and a perineal mass of 24-hour duration, which had been first observed immediately after parturition. Parturition had occurred at low ambient temperature, and only one puppy survived out of the seven oversized fetuses. The dog was in poor body condition, dehydrated, hypothermic, depressed, non-ambulatory and in a state of shock. Intestinal loops, the urinary bladder and the uterine horns and body were protruding from the vulva. A true vaginal prolapse was also observed. The abdominal viscera were flushed with warm sterile saline solution, protected and maintained wet. The laboratory findings included moderate anaemia, leukocytosis, hypoalbuminaemia, azotaemia and elevated liver enzyme activities. Stabilisation of the dog's general condition was attempted before surgery. Antimicrobial and analgesic drugs were also administered. After exploratory laparotomy the protruding organs, which were in good condition, were reduced. A recent rupture in the vaginal wall, approximately 6 cm long, was observed. Ovariohysterectomy and partial vaginectomy were performed. The preoperative course of therapy was continued, but the bitch died 12 hours later. The probable cause of vaginal rupture and evisceration in this bitch was tenesmus and/or trauma due to the oversized fetuses.

  8. Vernix caseosa peritonitis after vaginal delivery.

    Science.gov (United States)

    Sadath, Shameema A; Abo Diba, Fathiya I; Nayak, Surendra; Shamali, Iman Al; Diejomaoh, Michael F

    2013-01-01

    Vernix caseosa peritonitis (VCP) is a very unusual complication caused by inflammatory response to amniotic fluid spilled into the maternal peritoneal cavity. Twenty-seven cases have been reported, and all occurred after cesarean section. We present a case of VCP following vaginal delivery; this may be the first case reported after vaginal delivery. Mrs. A, 28 years old, gravida 3, para 2, with one previous cesarean section, was admitted at 41 weeks gestation in active labor. Vacuum extraction was performed to deliver a healthy male baby, 4.410 kg, Apgar scores 7, 8. She developed fever, acute abdominal pain, and distension about 3 hours after delivery. A diagnosis of acute abdomen was made. Laparotomy was performed and it revealed neither uterine scar rupture nor other surgical emergencies, but 500 mL of turbid fluid and some cheesy material on the serosal surface of all viscera. Biopsies were taken. She had a course of antibiotics and her recovery was complete. Histology of the peritoneal fluid and tissue biopsy resulted in a diagnosis of VCP. Clinical diagnosis of peritonitis due to vernix caseosa should be considered in patients presenting postpartum with an acute abdomen after vaginal delivery.

  9. Vaginal agenesis: Experience with sigmoid colon neovaginoplasty

    Directory of Open Access Journals (Sweden)

    Rawat Jiledar

    2010-01-01

    Full Text Available Aim: Objective of this study is to report our experience with sigmoid vaginoplasty in adolescents. Materials and Methods: A retrospective study of children with vaginal atresia and Mayer-Rokitansky-Kuster-Hauser syndrome. The sigmoid segment was used for vaginoplasty in all the cases. Results: Eight children were studied over a period of 7 years. The postoperative complications were ileus in 2, mucosal prolapse of the neovagina in 1, and minor wound infection in 1 patient. Seven patients are on regular follow-up. All the neovaginas were patent and functional. One patient had unacceptable perineal appearance, that is, badly scarred perineum as a late complication. None of the patients had vaginal stenosis or excessive mucus discharge, during follow-up visits. Out of the 7 patients, 2 patients are sexually active and satisfied. Conclusions: Sigmoid vaginoplasty is a safe and acceptable procedure for vaginal agenesis with good cosmetic results and acceptable complications rate. Sigmoid colon vaginoplasty is the treatment of choice because of its large lumen, thick walls resistant to trauma, adequate secretion allowing lubrication, not necessitating prolonged dilatation, and short recovery time.

  10. Development of picosecond pulsed electron beam monitor

    International Nuclear Information System (INIS)

    Hosono, Y.; Nakazawa, M.; Ueda, T.; Kobayasi, T.; Yosida, Y.; Ohkuma, J.; Okuda, S.; Suemine, S.

    1993-01-01

    For the picosecond pulsed electron beam of a linear accelerator a simple monitor using an electric connector has been developed which is constructed with SMA, BNC, N type electric connector through pipe (inner diameter = 50 mm or 100 mm). Under the measurement conditions of peak current (26A-900A) and narrow pulse width (Pw = 10 ps(FWHM), Pw = 30 ps(FWHM)), the following characteristics of this monitor were obtained, (A) rise time is less than 25 ps (B) the amplitude of the monitor output pulse is proportional directly to the area of cross section of the electrode. (author)

  11. Pulsed feedback defers cellular differentiation.

    Directory of Open Access Journals (Sweden)

    Joe H Levine

    2012-01-01

    Full Text Available Environmental signals induce diverse cellular differentiation programs. In certain systems, cells defer differentiation for extended time periods after the signal appears, proliferating through multiple rounds of cell division before committing to a new fate. How can cells set a deferral time much longer than the cell cycle? Here we study Bacillus subtilis cells that respond to sudden nutrient limitation with multiple rounds of growth and division before differentiating into spores. A well-characterized genetic circuit controls the concentration and phosphorylation of the master regulator Spo0A, which rises to a critical concentration to initiate sporulation. However, it remains unclear how this circuit enables cells to defer sporulation for multiple cell cycles. Using quantitative time-lapse fluorescence microscopy of Spo0A dynamics in individual cells, we observed pulses of Spo0A phosphorylation at a characteristic cell cycle phase. Pulse amplitudes grew systematically and cell-autonomously over multiple cell cycles leading up to sporulation. This pulse growth required a key positive feedback loop involving the sporulation kinases, without which the deferral of sporulation became ultrasensitive to kinase expression. Thus, deferral is controlled by a pulsed positive feedback loop in which kinase expression is activated by pulses of Spo0A phosphorylation. This pulsed positive feedback architecture provides a more robust mechanism for setting deferral times than constitutive kinase expression. Finally, using mathematical modeling, we show how pulsing and time delays together enable "polyphasic" positive feedback, in which different parts of a feedback loop are active at different times. Polyphasic feedback can enable more accurate tuning of long deferral times. Together, these results suggest that Bacillus subtilis uses a pulsed positive feedback loop to implement a "timer" that operates over timescales much longer than a cell cycle.

  12. Effect of Vaginal or Systemic Estrogen on Dynamics of Collagen Assembly in the Rat Vaginal Wall1

    Science.gov (United States)

    Montoya, T. Ignacio; Maldonado, P. Antonio; Acevedo, Jesus F.; Word, R. Ann

    2014-01-01

    ABSTRACT The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. PMID:25537371

  13. Recurrent, purulent vaginal discharge associated with longstanding presence of a foreign body and vaginal stenosis.

    Science.gov (United States)

    Simon, Deborah A; Berry, Scott; Brannian, John; Hansen, Keith

    2003-12-01

    A 13-year-old presented with malodorous, purulent, vaginal discharge following each menses for the last three months since menarche. This discharge resolved following antibiotic therapy but recurred with each menses. On exam, the patient was found to have a blind ending vagina with a small, midline perforation. Ultrasound and MRI examinations done prior to surgery did not identify the vaginal foreign body. She was taken to the operating room for examination under anesthesia and vaginoscopy. During surgery this area was found to be comprised of dense adhesions which nearly obliterated the distal vagina. The vaginal adhesions were lysed and a plastic foreign body was discovered in the upper vagina. After removing the foreign body the superior vagina was undermined, pulled down, and sutured to normal inferior vagina. A Mentor mold was placed in the vagina to maintain patency.

  14. Automation of loop amplitudes in numerical approach

    International Nuclear Information System (INIS)

    Fujimoto, J.; Ishikawa, T.; Shimizu, Y.; Kato, K.; Nakazawa, N.; Kaneko, T.

    1997-01-01

    An automatic calculating system GRACE-L1 of one-loop Feynman amplitude is reviewed. This system can be applied to 2 to 2-body one-loop processes. A sample calculation of 2 to 3-body one-loop amplitudes is also presented. (orig.)

  15. On the singularities of massive superstring amplitudes

    NARCIS (Netherlands)

    Foda, O.

    1987-01-01

    Superstring one-loop amplitudes with massive external states are shown to be in general ill-defined due to internal on-shell propagators. However, we argue that since any massive string state (in the uncompactified theory) has a finite lifetime to decay into massless particles, such amplitudes are

  16. Scattering Amplitudes via Algebraic Geometry Methods

    DEFF Research Database (Denmark)

    Søgaard, Mads

    Feynman diagrams. The study of multiloop scattering amplitudes is crucial for the new era of precision phenomenology at the Large Hadron Collider (LHC) at CERN. Loop-level scattering amplitudes can be reduced to a basis of linearly independent integrals whose coefficients are extracted from generalized...

  17. Full amplitude models of 15 day Cepheids

    International Nuclear Information System (INIS)

    Cogan, B.C.; Cox, A.N.; King, D.S.

    1980-01-01

    Numerical models of Cepheids have been computed with a range of effective temperatures and compositions. The amplitudes increase if the helium abundance increases or if the effective temperature decreases. The latter effect is contrary to observational data. The models also exhibit velocity amplitudes which are much lower than those observed

  18. Helicity amplitudes for matter-coupled gravity

    International Nuclear Information System (INIS)

    Aldrovandi, R.; Novaes, S.F.; Spehler, D.

    1992-07-01

    The Weyl-van der Waerden spinor formalism is applied to the evaluation of helicity invariant amplitudes in the framework of linearized gravitation. The graviton couplings to spin-0, 1 - 2 , 1, and 3 - 2 particles are given, and, to exhibit the reach of this method, the helicity amplitudes for the process electron + positron → photon + graviton are obtained. (author)

  19. Dependence of adiabatic population transfer on pulse profile

    Indian Academy of Sciences (India)

    Control of population transfer by rapid adiabatic passage has been an established technique wherein the exact amplitude profile of the shaped pulse is considered to be insignificant. We study the effect of ultrafast shaped pulses for two-level systems, by density-matrix approach. However, we find that adiabaticity depends ...

  20. Electromagnetic pulses in a strongly magnetized electron-positron plasma

    International Nuclear Information System (INIS)

    Yu, M.Y.; Rao, N.N.

    1985-01-01

    The conditions for the existence of large-amplitude localized electromagnetic wave pulses in an electron-positron plasma penetrated by a very strong ambient magnetic field are obtained. It is shown that such pulses can exist in pulsar polar magnetospheres. 12 references

  1. Characteristics of short pulse grid pulser for an electron LINAC

    International Nuclear Information System (INIS)

    Wang Guicheng; Fang Zhigao; Hong Jun

    1996-01-01

    An equivalent circuit is used to obtain the output waveform of a short pulse grid pulser for an electron LINAC, and the amplitude of the output pulse is studied as a function of number of switching transistors for some kinds of transistor. Two pulsers were fabricated to fulfill the requirements of the 200 MeV LINAC at NSRL

  2. Audibility of high harmonics in a periodic pulse

    NARCIS (Netherlands)

    Duifhuis, H.

    1970-01-01

    A periodic pulse consisting of sufficiently narrow pulses has a frequency spectrum which contains all harmonics with equal amplitude. Owing to the limited resolving power of the hearing organ, only the low harmonics can be perceived separately. The high harmonics are heard together as one complex

  3. An unusual cause of vaginal discharge following gender reassignment.

    Science.gov (United States)

    Sukumaran, S; Moran, P A; Makar, A

    2009-02-01

    Neovaginal reconstruction is an important part of gender reassignment surgery. We report a case of stone formation at the apex of vaginal vault constructed with sigmoid colon segment. A 48-year-old woman presented with profuse vaginal discharge for 1 year. She had a history of gender reassignment surgery (male to female) in 1994, and the neovagina had been constructed with an isolated sigmoid colon. Vaginoscopy performed using a cystoscope revealed multiple calculi at the vaginal vault on the endoscopic gastrointestinal anastomosis staples that had been used to close the vault. Colon-vaginoplasty has the advantages of providing adequate lubrication, but excessive vaginal discharge could be a problem, as colon is a mucous membrane. Stone formation in the vaginal vault should be considered in cases of gender reassignment with persistent vaginal discharge. This case also highlights the use of cystoscope in visualising the upper vagina in difficult circumstances.

  4. New relations for gauge-theory amplitudes

    International Nuclear Information System (INIS)

    Bern, Z.; Carrasco, J. J. M.; Johansson, H.

    2008-01-01

    We present an identity satisfied by the kinematic factors of diagrams describing the tree amplitudes of massless gauge theories. This identity is a kinematic analog of the Jacobi identity for color factors. Using this we find new relations between color-ordered partial amplitudes. We discuss applications to multiloop calculations via the unitarity method. In particular, we illustrate the relations between different contributions to a two-loop four-point QCD amplitude. We also use this identity to reorganize gravity tree amplitudes diagram by diagram, offering new insight into the structure of the Kawai-Lewellen-Tye (KLT) relations between gauge and gravity tree amplitudes. This insight leads to similar but novel relations. We expect this to be helpful in higher-loop studies of the ultraviolet properties of gravity theories.

  5. Providers' Experiences with Vaginal Dilator Training for Patients with Vaginal Agenesis.

    Science.gov (United States)

    Patel, Vrunda; Hakim, Julie; Gomez-Lobo, Veronica; Amies Oelschlager, Anne-Marie

    2018-02-01

    To examine providers' experiences with vaginal dilator training for patients with vaginal agenesis. Anonymous electronic survey. Members of the North American Society for Pediatric and Adolescent Gynecology. How providers learn about vaginal dilator training, common techniques, and methods used for patient training, assessment of patient readiness, common patient complaints, issues leading to early discontinuation. There were a total of 55 completed survey responses of which 31 respondents (56%) had been in practice for more than 10 years. Forty-nine were gynecologists (89%), 20 had completed a fellowship in pediatric and adolescent gynecology (36%), and 6 were reproductive endocrinologists (11%). Thirty-one respondents had first learned about vaginal dilator training through lectures (56%) whereas only 9 through mentorship and fellowship (16%). According to respondents, the most common issue leading to early discontinuation was lack of patient motivation and readiness (n = 42; 76%). The most common complication was pain or discomfort (n = 45; 82%). More than half of respondents determined dilator therapy was successful when patients reported comfortable sexual intercourse (n = 30; 55%) and 65% (n = 35) did not delineate any restrictions to initiation of sexual intercourse. Most respondents (87%) requested further vaginal dilator training at either a clinical meeting (n = 26; 47%) or with a training video (n = 22; 40%). Our study in an experienced cohort of pediatric gynecology providers highlights the need for further research and training on vaginal dilation education. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  6. Propagation of complex shaped ultrafast pulses in highly optically dense samples

    International Nuclear Information System (INIS)

    Davis, J. C.; Fetterman, M. R.; Warren, W. S.; Goswami, D.

    2008-01-01

    We examine the propagation of shaped (amplitude- and frequency-modulated) ultrafast laser pulses through optically dense rubidium vapor. Pulse reshaping, stimulated emission dynamics, and residual electronic excitation all strongly depend on the laser pulse shape. For example, frequency swept pulses, which produce adiabatic passage in the optically thin limit (independent of the sign of the frequency sweep), behave unexpectedly in optically dense samples. Paraxial Maxwell optical Bloch equations can model our ultrafast pulse propagation results well and provide insight

  7. A Novel Subnanosecond Monocycle Pulse Generator for UWB Radar Applications

    Directory of Open Access Journals (Sweden)

    Xinfan Xia

    2014-01-01

    Full Text Available A novel ultra-wideband (UWB monocycle pulse generator with good performance is designed and demonstrated in this paper. It contains a power supply circuit, a pulse drive circuit, a unique pulse forming circuit, and a novel monopolar-to-monocycle pulse transition circuit. The drive circuit employs wideband bipolar junction transistors (BJTs and linear power amplifier transistor to produce a high amplitude drive pulse, and the pulse forming circuit uses the transition characteristics of step recovery diode (SRD effectively to produce a negative narrow pulse. At last, the monocycle pulse forming circuit utilizes a novel inductance L short-circuited stub to generate the monocycle pulse directly. Measurement results show that the waveform of the generated monocycle pulses is over 76 V in peak-to-peak amplitude and 3.2 ns in pulse full-width. These characteristics of the monocycle pulse are advantageous for obtaining long detection range and high resolution, when it is applied to ultra-wideband radar applications.

  8. A compact nanosecond pulse generator for DBD tube characterization

    Science.gov (United States)

    Rai, S. K.; Dhakar, A. K.; Pal, U. N.

    2018-03-01

    High voltage pulses of very short duration and fast rise time are required for generating uniform and diffuse plasma under various operating conditions. Dielectric Barrier Discharge (DBD) has been generated by high voltage pulses of short duration and fast rise time to produce diffuse plasma in the discharge gap. The high voltage pulse power generators have been chosen according to the requirement for the DBD applications. In this paper, a compact solid-state unipolar pulse generator has been constructed for characterization of DBD plasma. This pulsar is designed to provide repetitive pulses of 315 ns pulse width, pulse amplitude up to 5 kV, and frequency variation up to 10 kHz. The amplitude of the output pulse depends on the dc input voltage. The output frequency has been varied by changing the trigger pulse frequency. The pulsar is capable of generating pulses of positive or negative polarity by changing the polarity of pulse transformer's secondary. Uniform and stable homogeneous dielectric barrier discharge plasma has been produced successfully in a xenon DBD tube at 400-mbar pressure using the developed high voltage pulse generator.

  9. Effects of a One Year Reusable Contraceptive Vaginal Ring on Vaginal Microflora and the Risk of Vaginal Infection: An Open-Label Prospective Evaluation.

    Science.gov (United States)

    Huang, Yongmei; Merkatz, Ruth B; Hillier, Sharon L; Roberts, Kevin; Blithe, Diana L; Sitruk-Ware, Régine; Creinin, Mitchell D

    2015-01-01

    A contraceptive vaginal ring (CVR) containing Nestorone® (NES) and ethinyl estradiol (EE) that is reusable for 1- year (13 cycles) is under development. This study assessed effects of this investigational CVR on the incidence of vaginal infections and change in vaginal microflora. There were 120 women enrolled into a NES/EE CVR Phase III trial and a microbiology sub-study for up to 1- year of cyclic product use. Gynecological examinations were conducted at baseline, the first week of cycle 6 and last week of cycle 13 (or during early discontinuation visits). Vaginal swabs were obtained for wet mount microscopy, Gram stain and culture. The CVR was removed from the vagina at the last study visit and cultured. Semi-quantitative cultures for Lactobacillus, Gardnerella vaginalis, Enterococcus faecalis, Staphylococcus aureus, Escherichia coli, anaerobic gram negative rods (GNRs), Candida albicans and other yeasts were performed on vaginal and CVR samples. Vaginal infections were documented throughout the study. Over 1- year of use, 3.3% of subjects were clinically diagnosed with bacterial vaginosis, 15.0% with vulvovaginal candidiasis, and 0.8% with trichomoniasis. The detection rate of these three infections did not change significantly from baseline to either Cycle 6 or 13. Nugent scores remained stable. H2O2-positive Lactobacillus dominated vaginal flora with a non-significant prevalence increase from 76.7% at baseline to 82.7% at cycle 6 and 90.2% at cycle 13, and a median concentration of 107 colony forming units (cfu) per gram. Although anaerobic GNRs prevalence increased significantly, the median concentration decreased slightly (104 to 103cfu per gram). There were no significant changes in frequency or concentrations of other pathogens. High levels of agreement between vaginal and ring surface microbiota were observed. Sustained use of the NES/EE CVR did not increase the risk of vaginal infection and was not disruptive to the vaginal ecosystem. Clinical

  10. The treatment of postmenopausal vaginal atrophy with ovestin

    NARCIS (Netherlands)

    Kicovic, P.M.; Cortesprieto, J.; Milojevic, S.; Haspels, A.A.; Aljinovic, A.

    1980-01-01

    Seventy-four postmenopausal women presenting with vaginal atrophy were treated with either Ovestin® vaginal cream (Group A, 23 women: 1 mg/day E3; Group B, 30 women: 0.5 mg/day E3) or vaginal suppositories (Group C, 21 women: 0.5 mg/day E3), applied daily for 3 wk (A and B) or 2 wk (C) before

  11. Relationship between lactobacilli and opportunistic bacterial pathogens associated with vaginitis.

    Science.gov (United States)

    Razzak, Mohammad Sabri A; Al-Charrakh, Alaa H; Al-Greitty, Bara Hamid

    2011-04-01

    Vaginitis, is an infectious inflammation of the vaginal mucosa, which sometimes involves the vulva. The balance of the vaginal flora is maintained by the Lactobacilli and its protective and probiotic role in treating and preventing vaginal infection by producing antagonizing compounds which are regarded as safe for humans. The aim of this study was to evaluate the protective role of Lactobacilli against common bacterial opportunistic pathogens in vaginitis and study the effects of some antibiotics on Lactobacilli isolates. In this study (110) vaginal swabs were obtained from women suffering from vaginitis who admitted to Babylon Hospital of Maternity and Paediatrics in Babylon province, Iraq. The study involved the role of intrauterine device among married women with vaginitis and also involved isolation of opportunistic bacterial isolates among pregnant and non pregnant women. This study also involved studying probiotic role of Lactobacilli by production of some defense factors like hydrogen peroxide, bacteriocin, and lactic acid. Results revealed that a total of 130 bacterial isolates were obtained. Intrauterine device was a predisposing factor for vaginitis. The most common opportunistic bacterial isolates were Staphylococcus aureus, Escherichia coli, Streptococcus agalactiae, and Klebsiella pneumoniae. All Lactobacilli were hydrogen peroxide producers while some isolates were bacteriocin producers that inhibited some of opportunistic pathogens (S. aureus, E. coli). Lactobacilli were sensitive to erythromycin while 93.3% of them were resistant to ciprofloxacin and (40%, 53.3%) of them were resistant to amoxicillin and gentamycin respectively. Results revealed that there was an inverse relationship between Lactobacilli presence and organisms causing vaginitis. This may be attributed to the production of defense factors by Lactobacilli. The types of antibiotics used to treat vaginitis must be very selective in order not to kill the beneficial bacteria

  12. Vaginal Approaches Using Synthetic Mesh to Treat Pelvic Organ Prolapse

    OpenAIRE

    Moon, Jei Won; Chae, Hee Dong

    2016-01-01

    Pelvic organ prolapse (POP) is a very common condition in elderly women. In women with POP, a sacrocolpopexy or a vaginal hysterectomy with anterior and posterior colporrhaphy has long been considered as the gold standard of treatment. However, in recent decades, the tendency to use a vaginal approach with mesh for POP surgery has been increasing. A vaginal approach using mesh has many advantages, such as its being less invasive than an abdominal approach and easier to do than a laparoscopic ...

  13. High-voltage short-fall pulse generator

    International Nuclear Information System (INIS)

    Dolbilov, G.V.; Fateev, A.A.; Petrov, V.A.

    1986-01-01

    Powerful high-voltage pulses with short fall times and relatively low afterpulse amplitude are required for the deflection systems of accelerators. A generator is described that provides, into a 75-ohm load, a voltage pulse of up to 100 kV with a fall time of less than 1 nsec and a relative afterpulse amplitude of less than or equal to 15%. The generator employs a short-circuited ferrite-filled line in which shock waves are formed. A magnetic section is used to increase power. The switch is a TGI1-2500/50 thyratron. The main causes of afterpulses and methods for reducing their amplitude are examined

  14. Parturition pit: the bony imprint of vaginal birth

    International Nuclear Information System (INIS)

    McArthur, Tatum A.; Meyer, Isuzu; Jackson, Bradford; Pitt, Michael J.; Larrison, Matthew C.

    2016-01-01

    To retrospectively evaluate for pits along the dorsum of the pubic body in females and compare the presence/absence of these pits to vaginal birth data. We retrospectively reviewed females with vaginal birth data who underwent pelvic CT. The presence of pits along the dorsum of the pubic body, pit grade (0 = not present; 1 = faintly imperceptible; 2 = present; 3 = prominent), and the presence of osteitis condensans ilii, preauricular sulcus, and sacroiliac joint vacuum phenomenon were assessed on imaging. Musculoskeletal radiologists who were blinded to the birth data evaluated the CTs. 48 males were also evaluated for the presence of pits. 482 female patients underwent CT pelvis and 171 were excluded due to lack of vaginal birth data. Of the 311 study patients, 262 had prior vaginal birth(s) and 194 had pits on CT. Only 7 of the 49 patients without prior vaginal birth had pits. There was a statistically significant association between vaginal birth and presence of pits (p < 0.0001). Patients with more prominent pits (grades 2/3) had a greater number of vaginal births. As vaginal deliveries increased, the odds of having parturition pits greatly increased, adjusting for age and race at CT (p < 0.0001). No males had pits. Our study indicates that parturition pits are associated with prior vaginal birth and should be considered a characteristic of the female pelvis. The lytic appearance of prominent pits on imaging can simulate disease and create a diagnostic dilemma for interpreting radiologists. (orig.)

  15. Human vaginal pH and microbiota: an update.

    Science.gov (United States)

    Godha, Keshav; Tucker, Kelly M; Biehl, Colton; Archer, David F; Mirkin, Sebastian

    2018-06-01

    A woman's vaginal pH has many implications on her health and it can be a useful tool in disease diagnosis and prevention. For that reason, the further examination of the relationship between the human vaginal pH and microbiota is imperative. In the past several decades, much has been learned about the physiological mechanisms modulating the vaginal pH, and exogenous/genetic factors that may influence it. A unified, coherent understanding of these concepts is presented to comprehend their interrelationships and their cumulative effect on a woman's health. In this review, we explore research on vaginal pH and microbiota throughout a woman's life, vaginal intermediate cell anaerobic metabolism and net proton secretion by the vaginal epithelial, and the way these factors interact to acidify the vaginal pH. This review provides foundational information about what a microbiota is and its relationship with human physiology and vaginal pH. We then evaluate the influence of physiological mechanisms, demographic factors, and propose ideas for the mechanisms behind their action on the vaginal pH.

  16. [Vaginal disbacteriosis--social and sexual risk factors].

    Science.gov (United States)

    Kovachev, S

    2013-01-01

    The vaginal microbe equilibrium could be impaired by different agents. Many of the risk factors can change the preventive mechanisms of the vagina and can lead to inflammation and disease. We even do not suppose about the role of most of them in impairing of vaginal microbe equilibrium. The exact understanding of those risk factors and mechanisms by which they disturb the vaginal microbe balance could reduce female morbidity of vaginal disbacteriosis and vaginal inflammations. The aim of this literature synopsis is to review some of the most frequent risk factors for vaginal disbacteriosis and about how they change vaginal micro-flora with dominant lactobacillus within it. The most informative and detailed articles on the theme which were found in the resent literature as well as in Medline for the period between 1990 and 2012 were selected. The risk agents for vaginal disbacteriosis are: endogenetic, social, sexual, infectious and iatrogenic. The social and sexual factors are the most frequent in our daily round. The intensity and the kind of sexual life, smoking, homosexual connections, vaginal douching and contraception methods are included in them. All these factors depend on us. Thus we hope that through their popularization and discussion will help to prevent the females' health.

  17. [Vaginal metastasis revealing an adenocarcinoma of the transverse colon].

    Science.gov (United States)

    Quaranta, D; Delotte, J; Bongain, A; François, E; Bereder, J-M; Bernard, J-L

    2014-09-01

    Secondary localization to vagina had a severe prognosis, suggesting a disseminated metatastic disease. We report the case of prevalent vaginal metastasis of adenocarcinoma of the transverse colon. A 65 years old patient has consulted for vaginal mass. After delayed diagnosis, she presented with disseminated metastatic disease with peritoneal carcinomatosis. After neoadjuvant chemotherapy, the following treatment consisted of complete cytoreductive surgery combined with hyperthermic intraperitoneal chemotherapy and vaginal adjuvant radiotherapy. No recurrence occurred after one year. Vaginal metastasis of colon cancer are rare. The dark prognosis might justify a systematic gynecological examination of women presenting colorectal neoplasy. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Ureterovaginal fistula: A complication of a vaginal foreign body

    Directory of Open Access Journals (Sweden)

    Tsia-Shu Lo

    2018-02-01

    Conclusion: Ureterovaginal fistula following neglected vaginal foreign body is a serious condition. Early diagnosis, treatment of infection and proper surgical management can improve the outcome and decrease complications.

  19. Effects of vaginal discharge on female sexual function.

    Science.gov (United States)

    Gungor, Ayse N C; Uludag, Aysegul; Sahin, Melih; Gencer, Meryem; Uysal, Ahmet

    2014-01-01

    To assess the effects of vaginal discharge on female sexual dysfunction (FSD) by using the Female Sexual Function Index (FSFI). In a study at a university hospital in Canakkale, Turkey, women affected by vaginal discharge and age-matched healthy control women were recruited between January and December 2012. Women were grouped in accordance with their vaginal discharge complaints and each participant completed the FSFI questionnaire. A total of 114 women were included in the study. Women in the first group (n=58) had no vaginal discharge or had physiologic vaginal discharge, those in the second group (n=29) had abnormal vaginal discharge with itching, and those in the third group (n=27) had abnormal vaginal discharge without itching. Compared with the first group, women in the second and third groups had higher FSFI scores for desire, arousal, orgasm, and pain, in addition to higher overall FSFI scores. Women with genital malodor had significantly higher FSFI scores than patients without genital malodor (23.83 ± 5.07 vs 21.15 ± 4.78; P=0.008). Women with abnormal vaginal discharges were found to have better FSFI scores for some domains. This finding may be attributed to the adverse effects of sexual intercourse on vaginal infections. © 2013.

  20. Modeling study on the effects of pulse rise rate in atmospheric pulsed discharges

    Science.gov (United States)

    Zhang, Yuan-Tao; Wang, Yan-Hui

    2018-02-01

    In this paper, we present a modeling study on the discharge characteristics driven by short pulsed voltages, focusing on the effects of pulse rise rate based on the fluid description of atmospheric plasmas. The numerical results show that the breakdown voltage of short pulsed discharge is almost linearly dependent on the pulse rise rate, which is also confirmed by the derived equations from the fluid model. In other words, if the pulse rise rate is fixed as a constant, the simulation results clearly suggest that the breakdown voltage is almost unchanged, although the amplitude of pulsed voltage increases significantly. The spatial distribution of the electric field and electron density are given to reveal the underpinning physics. Additionally, the computational data and the analytical expression also indicate that an increased repetition frequency can effectively decrease the breakdown voltage and current density, which is consistent with the experimental observation.

  1. System and process for pulsed multiple reaction monitoring

    Science.gov (United States)

    Belov, Mikhail E

    2013-05-17

    A new pulsed multiple reaction monitoring process and system are disclosed that uses a pulsed ion injection mode for use in conjunction with triple-quadrupole instruments. The pulsed injection mode approach reduces background ion noise at the detector, increases amplitude of the ion signal, and includes a unity duty cycle that provides a significant sensitivity increase for reliable quantitation of proteins/peptides present at attomole levels in highly complex biological mixtures.

  2. Nonlinear shaping of a two-dimensional ultrashort ionizing pulse

    International Nuclear Information System (INIS)

    Sergeev, A.; Vanin, E.; Stenflo, L.; Anderson, D.; Lisak, M.; Quiroga-Teixeiro, M.L.

    1992-01-01

    A theoretical description of ultrashort ionizing wave pulses is presented by means of two different models where the ionization rate increases or decreases, respectively, as a function of the electric field amplitude. We show that the pulse evolves either into a horse-shoe or a horn-type structure in the time-space domain. In some parameter regions the intensity of the pulse can also increase. (au)

  3. Removal of residual nuclei following a cavitation event using low-amplitude ultrasound.

    Science.gov (United States)

    Duryea, Alexander P; Cain, Charles A; Tamaddoni, Hedieh A; Roberts, William W; Hall, Timothy L

    2014-10-01

    Microscopic residual bubble nuclei can persist on the order of 1 s following a cavitation event. These bubbles can limit the efficacy of ultrasound therapies such as shock wave lithotripsy and histotripsy, because they attenuate pulses that arrive subsequent to their formation and seed repetitive cavitation activity at a discrete set of sites (cavitation memory). Here, we explore a strategy for the removal of these residual bubbles following a cavitation event, using low-amplitude ultrasound pulses to stimulate bubble coalescence. All experiments were conducted in degassed water and monitored using high-speed photography. In each case, a 2-MHz histotripsy transducer was used to initiate cavitation activity (a cavitational bubble cloud), the collapse of which generated a population of residual bubble nuclei. This residual nuclei population was then sonicated using a 1 ms pulse from a separate 500-kHz transducer, which we term the bubble removal pulse. Bubble removal pulse amplitudes ranging from 0 to 1.7 MPa were tested, and the backlit area of shadow from bubbles remaining in the field following bubble removal was calculated to quantify efficacy. It was found that an ideal amplitude range exists (roughly 180 to 570 kPa) in which bubble removal pulses stimulate the aggregation and subsequent coalescence of residual bubble nuclei, effectively removing them from the field. Further optimization of bubble removal pulse sequences stands to provide an adjunct to cavitation-based ultrasound therapies such as shock wave lithotripsy and histotripsy, mitigating the effects of residual bubble nuclei that currently limit their efficacy.

  4. Effects of strength training on mechanomyographic amplitude

    International Nuclear Information System (INIS)

    DeFreitas, Jason M; Beck, Travis W; Stock, Matt S

    2012-01-01

    The aim of the present study was to determine if the patterns of mechanomyographic (MMG) amplitude across force would change with strength training. Twenty-two healthy men completed an 8-week strength training program. During three separate testing visits (pre-test, week 4, and week 8), the MMG signal was detected from the vastus lateralis as the subjects performed isometric step muscle actions of the leg extensors from 10–100% of maximal voluntary contraction (MVC). During pre-testing, the MMG amplitude increased linearly with force to 66% MVC and then plateaued. Conversely, weeks 4 and 8 demonstrated an increase in MMG amplitude up to ∼85% of the subject's original MVC before plateauing. Furthermore, seven of the ten force levels (30–60% and 80–100%) showed a significant decrease in mean MMG amplitude values after training, which consequently led to a decrease in the slope of the MMG amplitude/force relationship. The decreases in MMG amplitude at lower force levels are indicative of hypertrophy, since fewer motor units would be required to produce the same absolute force if the motor units increased in size. However, despite the clear changes in the mean values, analyses of individual subjects revealed that only 55% of the subjects demonstrated a significant decrease in the slope of the MMG amplitude/force relationship. (paper)

  5. A longitudinal analysis of the vaginal microbiota and vaginal immune mediators in women from sub-Saharan Africa

    OpenAIRE

    Jespers, V.; Kyongo, J.; Joseph, S.; Hardy, L.; Cools, P.; Crucitti, T.; Mwaura, M.; Ndayisaba, G.; Delany-Moretlwe, S.; Buyze, J.; Vanham, G.; van de Wijgert, JHHM

    2017-01-01

    In cross-sectional studies increased vaginal bacterial diversity has been associated with vaginal inflammation which can be detrimental for health. We describe longitudinal changes at 5 visits over 8 weeks in vaginal microbiota and immune mediators in African women. Women (N = 40) with a normal Nugent score at all visits had a stable lactobacilli dominated microbiota with prevailing Lactobacillus iners. Presence of prostate-specific antigen (proxy for recent sex) and being amenorrhoeic (due t...

  6. A case of laparoscopy-assisted vaginal cuff suturing for vaginal cuff dehiscence after total laparoscopic hysterectomy

    Directory of Open Access Journals (Sweden)

    Tomoatsu Jimi

    Full Text Available Introduction: Vaginal cuff dehiscence after hysterectomy is a rare complication and occurs in less than 1% of patients. It can present with serious complications, such as bowel evisceration and peritonitis. Presentation of case: A 51-year-old multigravida Korean woman underwent total laparoscopic hysterectomy for leiomyoma. Six months later, she reported lower abdominal pain and vaginal bleeding. Physical examination revealed rebound tenderness in the lower abdomen, and pelvic examination showed a small amount of vaginal bleeding with an evisceration of the small intestine through the vagina that exhibited healthy peristalsis. The eviscerated bowel, which seemed to be a part of the ileum, was carefully manually reduced transvaginally into the abdominal cavity. Laparoscopic observation revealed adhesions between the omentum, small intestine, and the peritoneum. Specifically, the small intestine was adhered around the vaginal cuff. An abdominal abscess was found in the left lower abdominal cavity. An adhesiotomy was performed and the abdominal abscess was removed and irrigated. Complete separation of the anterior and posterior vaginal cuff edges was obtained. The vaginal cuff was closed with interrupted 0-polydioxanone absorbable sutures without bowel injury. A 6-month follow-up examination revealed complete healing of the vaginal cuff. Discussion: In this case, we were able to make use of both laparoscopic and transvaginal methods to perform a successful repair with a minimally invasive and safe technique. Conclusion: Laparoscopically assisted vaginal cuff suturing for vaginal cuff dehiscence after total laparoscopic hysterectomy was found to be effective, safe, and minimally invasive. Keywords: Vaginal cuff dehiscence, Vaginal cuff repair, Vaginal cuff evisceration, Laparoscopic hysterectomy, Complication

  7. The random signal generator of imitated nuclear radiation pulse

    International Nuclear Information System (INIS)

    Li Dongcang; Yang Lei; Yuan Shulin; Yang Yinghui; Zang Fujia

    2007-01-01

    Based in pseudo-random uniformity number, it produces random numbers of Gaussian distribution and exponential distribution by arithmetic. The hardware is the single-chip microcomputer of 89C51. Program language makes use of Keil C. The output pulse amplitude is Gaussian distribution, exponential distribution or uniformity distribution. Likewise, it has two mode or upwards two. The time alternation of output pulse is both periodic and exponential distribution. The generator has achieved output control of multi-mode distribution, imitated random characteristic of nuclear pulse in amplitude and in time. (authors)

  8. Pulsed power

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The key element of our pulsed power program is concentration of power in time and space by suppression of breakdown in dielectrics and in vacuum. Magnetically insulated vacuum transmission lines and magnetic suppression of insulator flashover have continued as the main reserch directions. Vacuum insulated line studies at Physics International have been expanded and a test bed at Sandia, called MITE (Magnetically Insulated Transmission Experiment), is under development. The choice for the baseline EBFA design will depend on the outcome of these studies and should be made in July 1977. The slow and intermediate speed pulsed power approaches to EBFA will be based on Proto I and Proto II results and several of the projected EBFA subsystems are presently being tested in Proto II. A further stage of power concentration, within the vacuum diode itself, would considerably ease the burden on dielectrics; methods of power multiplication involving magnetically imploded plasmas are being considered and tests have begun using the Ripple III apparatus

  9. Holographic corrections to meson scattering amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Armoni, Adi; Ireson, Edwin, E-mail: 746616@swansea.ac.uk

    2017-06-15

    We compute meson scattering amplitudes using the holographic duality between confining gauge theories and string theory, in order to consider holographic corrections to the Veneziano amplitude and associated higher-point functions. The generic nature of such computations is explained, thanks to the well-understood nature of confining string backgrounds, and two different examples of the calculation in given backgrounds are used to illustrate the details. The effect we discover, whilst only qualitative, is re-obtainable in many such examples, in four-point but also higher point amplitudes.

  10. Amplitude-Mode Dynamics of Polariton Condensates

    International Nuclear Information System (INIS)

    Brierley, R. T.; Littlewood, P. B.; Eastham, P. R.

    2011-01-01

    We study the stability of collective amplitude excitations in nonequilibrium polariton condensates. These excitations correspond to renormalized upper polaritons and to the collective amplitude modes of atomic gases and superconductors. They would be present following a quantum quench or could be created directly by resonant excitation. We show that uniform amplitude excitations are unstable to the production of excitations at finite wave vectors, leading to the formation of density-modulated phases. The physical processes causing the instabilities can be understood by analogy to optical parametric oscillators and the atomic Bose supernova.

  11. Hidden simplicity of gauge theory amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Drummond, J M, E-mail: drummond@lapp.in2p3.f [LAPTH, Universite de Savoie, CNRS, B.P. 110, F-74941 Annecy-le-Vieux, Cedex (France)

    2010-11-07

    These notes were given as lectures at the CERN Winter School on Supergravity, Strings and Gauge Theory 2010. We describe the structure of scattering amplitudes in gauge theories, focussing on the maximally supersymmetric theory to highlight the hidden symmetries which appear. Using the Britto, Cachzo, Feng and Witten (BCFW) recursion relations we solve the tree-level S-matrix in N=4 super Yang-Mills theory and describe how it produces a sum of invariants of a large symmetry algebra. We review amplitudes in the planar theory beyond tree level, describing the connection between amplitudes and Wilson loops, and discuss the implications of the hidden symmetries.

  12. Electronic system for recording proportional counter rare pulses with the pulse shape analysis

    International Nuclear Information System (INIS)

    Barabanov, I.R.; Gavrin, V.N.; Zakharov, Yu.I.; Tikhonov, A.A.

    1984-01-01

    The anutomated system for recording proportional counter rare pulses is described. The proportional counters are aimed at identification of 37 Ar and H7 1 Gr decays in chemical radiation detectors of solar neutrino. Pulse shape recording by means of a storage oscilloscope and a TV display is performed in the system considered besides two-parametric selection of events (measurement of pulse amplitude in a slow channel and the amplitude of pulse differentiated with time constant of about 10 ns in a parallel fast channel). Pulse discrimination by a front rise rate provides background decrease in the 55 Fe range (5.9 keV) by 6 times; the visual analysis of pulse shapes recorded allows to decrease the background additionally by 25-30%. The background counting rate in the 55 Fe range being equal to 1 pulse per 1.5 days, is obtained when using the installation described above, as well as the passive Pb shield 5 cm thick, and the active shield based on the anticoincidence NaI(Tl) detector with the cathode 5.6 mm in-diameter made of Fe fabircated by zone melting. The installation described allows to reach the background level of 0.6 pulse/day (the total coefficient of background attenuation is 400). Further background decrease is supposed to be provided by installation allocation in the low-noise underground laboratory of the Baksan Neutrino Observatory

  13. Control and performance improvements of a pulse compressor in use for testing accelerating structures at high power

    Directory of Open Access Journals (Sweden)

    Benjamin Woolley

    2017-10-01

    Full Text Available New developments relating to compact X-band, SLED-I type pulse compressors being developed at CERN for testing high gradient structures are described. Pulse compressors of interest take rf pulses from one or more high power klystrons with duration typically >1.5  μs and deliver up to 5 times the input power for a shorter duration <250  ns. Time domain models for pulse compressor operation with low level rf (LLRF control have been developed. Input drive amplitude and phase for each pulse is evolved with a control algorithm from the pulse compressor output for previous pulses. The goal is to deliver precise amplitude for pulses to test stands and precise amplitude and phase for pulses to accelerator systems. Control algorithms have been developed and validated experimentally.

  14. Repetitive transcranial magnetic stimulator with controllable pulse parameters

    Science.gov (United States)

    Peterchev, Angel V.; Murphy, David L.; Lisanby, Sarah H.

    2011-06-01

    The characteristics of transcranial magnetic stimulation (TMS) pulses influence the physiological effect of TMS. However, available TMS devices allow very limited adjustment of the pulse parameters. We describe a novel TMS device that uses a circuit topology incorporating two energy storage capacitors and two insulated-gate bipolar transistor (IGBT) modules to generate near-rectangular electric field pulses with adjustable number, polarity, duration, and amplitude of the pulse phases. This controllable pulse parameter TMS (cTMS) device can induce electric field pulses with phase widths of 10-310 µs and positive/negative phase amplitude ratio of 1-56. Compared to conventional monophasic and biphasic TMS, cTMS reduces energy dissipation up to 82% and 57% and decreases coil heating up to 33% and 41%, respectively. We demonstrate repetitive TMS trains of 3000 pulses at frequencies up to 50 Hz with electric field pulse amplitude and width variability less than the measurement resolution (1.7% and 1%, respectively). Offering flexible pulse parameter adjustment and reduced power consumption and coil heating, cTMS enhances existing TMS paradigms, enables novel research applications and could lead to clinical applications with potentially enhanced potency.

  15. Vaginal seeding or vaginal microbial transfer from the mother to the cesarean born neonate

    DEFF Research Database (Denmark)

    Haahr, Thor; Glavind, Julie; Axelsson, Paul

    2017-01-01

    Recent evidence suggests cesarean delivery (CD) to be a risk factor for inflammatory and metabolic diseases such as asthma, allergies and other chronic immune disorders in the child. One hypothetical pathogenesis of these associations has been proposed to be a disruption of the neonatal colonizat...... to children delivered vaginally. This article is protected by copyright. All rights reserved....

  16. Directed shift of vaginal microbiota induced by vaginal application of sucrose gel in rhesus macaques

    Directory of Open Access Journals (Sweden)

    Kai-tao Hu

    2015-04-01

    Conclusions: Rhesus macaques can be used as animal models of bacterial vaginosis to develop drugs and test treatment efficacy. Furthermore, the topical application of sucrose gel induced the shifting of vaginal flora of rhesus macaques from a BV kind of flora to a lactobacilli-dominating flora.

  17. Endovascular Management of Intractable Postpartum Hemorrhage Caused by Vaginal Laceration

    International Nuclear Information System (INIS)

    Koganemaru, Masamichi; Nonoshita, Masaaki; Iwamoto, Ryoji; Kuhara, Asako; Nabeta, Masakazu; Kusumoto, Masashi; Kugiyama, Tomoko; Kozuma, Yutaka; Nagata, Shuji; Abe, Toshi

    2016-01-01

    PurposeWe evaluated the management of transcatheter arterial embolization for postpartum hemorrhage caused by vaginal laceration.Materials and MethodsWe reviewed seven cases of patients (mean age 30.9 years; range 27–35) with intractable hemorrhages and pelvic hematomas caused by vaginal lacerations, who underwent superselective transcatheter arterial embolization from January 2008 to July 2014. Postpartum hemorrhage was evaluated by angiographic vascular mapping to determine the vaginal artery’s architecture, technical and clinical success rates, and complications.ResultsThe vaginal artery was confirmed as the source of bleeding in all cases. The artery was found to originate from the uterine artery in three cases, the uterine and obturator arteries in two, or the internal pudendal artery in two. After vaginal artery embolization, persistent contrast extravasation from the inferior mesenteric artery as an anastomotic branch was noted in one patient. Nontarget vessels (the inferior vesical artery and nonbleeding vaginal arterial branches) were embolized in one patient. Effective control of hemostasis and no post-procedural complications were confirmed for all cases.ConclusionPostpartum hemorrhages caused by vaginal lacerations involve the vaginal artery arising from the anterior trunk of the internal iliac artery with various branching patterns. Superselective vaginal artery embolization is clinically acceptable for the successful treatment of vaginal laceration hemorrhages, with no complications. After vaginal artery embolization, it is suggested to check for the presence of other possible bleeding vessels by pelvic aortography with a catheter tip at the L3 vertebral level, and to perform a follow-up assessment.

  18. Endovascular Management of Intractable Postpartum Hemorrhage Caused by Vaginal Laceration

    Energy Technology Data Exchange (ETDEWEB)

    Koganemaru, Masamichi, E-mail: mkoganemaru@med.kurume-u.ac.jp; Nonoshita, Masaaki, E-mail: z2rs-1973@yahoo.co.jp; Iwamoto, Ryoji, E-mail: iwamoto-ryouji@kurume-u.ac.jp; Kuhara, Asako, E-mail: kuhara-asako@med.kurume-u.ac.jp; Nabeta, Masakazu, E-mail: nabeta-masakazu@med.kurume-u.ac.jp; Kusumoto, Masashi, E-mail: kusumoto-masashi@med.kurume-u.ac.jp; Kugiyama, Tomoko, E-mail: kugiyama-tomoko@med.kurume-u.ac.jp [Kurume University School of Medicine, Department of Radiology (Japan); Kozuma, Yutaka, E-mail: kouduma-yutaka@kurume-u.ac.jp [Kurume University School of Medicine, Department of Obstetrics and Gynecology (Japan); Nagata, Shuji, E-mail: sn4735@med.kurume-u.ac.jp; Abe, Toshi, E-mail: toshiabe@med.kurume-u.ac.jp [Kurume University School of Medicine, Department of Radiology (Japan)

    2016-08-15

    PurposeWe evaluated the management of transcatheter arterial embolization for postpartum hemorrhage caused by vaginal laceration.Materials and MethodsWe reviewed seven cases of patients (mean age 30.9 years; range 27–35) with intractable hemorrhages and pelvic hematomas caused by vaginal lacerations, who underwent superselective transcatheter arterial embolization from January 2008 to July 2014. Postpartum hemorrhage was evaluated by angiographic vascular mapping to determine the vaginal artery’s architecture, technical and clinical success rates, and complications.ResultsThe vaginal artery was confirmed as the source of bleeding in all cases. The artery was found to originate from the uterine artery in three cases, the uterine and obturator arteries in two, or the internal pudendal artery in two. After vaginal artery embolization, persistent contrast extravasation from the inferior mesenteric artery as an anastomotic branch was noted in one patient. Nontarget vessels (the inferior vesical artery and nonbleeding vaginal arterial branches) were embolized in one patient. Effective control of hemostasis and no post-procedural complications were confirmed for all cases.ConclusionPostpartum hemorrhages caused by vaginal lacerations involve the vaginal artery arising from the anterior trunk of the internal iliac artery with various branching patterns. Superselective vaginal artery embolization is clinically acceptable for the successful treatment of vaginal laceration hemorrhages, with no complications. After vaginal artery embolization, it is suggested to check for the presence of other possible bleeding vessels by pelvic aortography with a catheter tip at the L3 vertebral level, and to perform a follow-up assessment.

  19. Unusual clinical presentation of rare case of vaginal leiomyoma: a case report

    OpenAIRE

    Ishrat Zuber; Purnima K. Nadkarni; Aditi A. Nadkarni; Akshay Nadkarni

    2016-01-01

    Primary vaginal leiomyoma are rare and usually arise from anterior vaginal wall, approximately 330 cases of vaginal fibroid reported in world literature. Vaginal myoma usually presented as discharge per vaginum, abnormal bleeding, pain lower abdomen, dyspareunia etc. We report a case of primary vaginal leiomyoma arising from lateral vaginal wall which is presented clinically as pain in hip joint and radiating to ipsilateral leg which is unusual clinical presentation creating diagnostic dilemm...

  20. The role of pulse shape in motor cortex transcranial magnetic stimulation using full-sine stimuli

    DEFF Research Database (Denmark)

    Delvendahl, Igor; Gattinger, Norbert; Berger, Thomas

    2014-01-01

    A full-sine (biphasic) pulse waveform is most commonly used for repetitive transcranial magnetic stimulation (TMS), but little is known about how variations in duration or amplitude of distinct pulse segments influence the effectiveness of a single TMS pulse to elicit a corticomotor response. Using......) compared monophasic, half-sine, and full-sine pulses, (ii) applied two-segment pulses consisting of two identical half-sines, and (iii) manipulated amplitude, duration, and current direction of the first or second full-sine pulse half-segments. RMT was significantly higher using half-sine or monophasic...... in considerably higher RMT, whereas varying the amplitude of the half-segment inducing anterior-posterior current had a smaller effect. These findings provide direct experimental evidence that the pulse segment inducing a posterior-anterior directed current in M1 contributes most to corticospinal pathway...

  1. Normal ovarian cycle in endo vaginal ultrasound

    International Nuclear Information System (INIS)

    Martinez, F.; Dualde, D.; Labrador, T.; Morales, F.J.; Vidal, P.; Gordo, G.

    1995-01-01

    The changing morphology of the endometrium and ovaries during the menstrual cycle can be viewed with great richness of image using high frequency (5-6-7.5 Mhz) probes in endo vaginal ultrasound. The radiological findings associated with the menstrual cycle are reviewed in terms of four phases (follicular, preovulatory, ovulatory and luteal) and a study is made of the changes that can lead to different morphologies, some of which, especially those of the corpus luteus, are peculiar. The need to be familiar with these changes in order to avoid confusing them with pathological signs is pointed out. (Author)

  2. Vaginal Lactobacillus isolates inhibit uropathogenic Escherichia coli.

    OpenAIRE

    Atassi , Fabrice; Brassart , Dominique; Grob , Philipp; Graf , Federico; Servin , Alain ,

    2006-01-01

    The purpose of this study was to investigate the antibacterial activities of Lactobacillus jensenii KS119.1 and KS121.1, and Lactobacillus gasserii KS120.1 and KS124.3 strains isolated from the vaginal microflora of healthy women, against uropathogenic, diffusely adhering Afa/Dr Escherichia coli (Afa/Dr DAEC) strains IH11128 and 7372 involved in recurrent cystitis. We observed that some of the Lactobacillus isolates inhibited the growth and decreased the viability of E. coli IH11128 and 7372....

  3. Vaginal contraceptive film gains wider acceptance.

    Science.gov (United States)

    1992-09-01

    In US health departments and family planning clinics, women are beginning to accept vaginal contraceptive film more widely. Further, direct sales of this method, which is also distributed over the counter, has increased. In fact, in 1991, vaginal contraceptive film was the top selling contraceptive in pharmacies. This 2.5 sq. inch water-soluble film is impregnated with nonoxynol-9. The woman uses her finger to insert the folded square as close as possible to the cervix 5-60 minutes before intercourse. If the time between acts of intercourse is greater than 1 hour, she must insert another square. After it dissolves, it is a firm gel removed by vaginal and cervical fluids. The company realizes that its relatively high cost (about $3.59 for 3 films) prevents some family planning providers from offering the film. It has tried to cut costs by not using extra packaging material and by manufacturing it in the US instead of ain England. A manager of the family planning clinic at R.E. Thomason County Hospital in El Paso, Texas, notes that user compliance is higher with the vaginal contraceptive film than foam. In fact, patients at the Planned Parenthood League of Middlesex County, New Jersey, favor the film because it is less messy than foam. Teenagers in El Paso prefer the film because of the privacy issue and gives them more control to protect themselves from pregnancy. A worker at the New Jersey clinic recommends the film as a backup method for women beginning to use oral contraceptives. She also suggests to patients requesting condoms to also use the film. The company makes the same recommendation. Yet, family planning workers note that some women cannot convince partners to use the condom. 90% of patients at the El Paso clinic are Hispanic, and they tend to not accept condom use. Some providers suggest using 2 applications of the film to defend against sexually transmitted diseases, but there is no evidence that double application actually does so.

  4. Radiation therapy of primary vaginal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Pirtoli, L; Santoni, R [Florence Univ. (Italy). Ist. di Radiologia

    1980-01-01

    In a series of 22 patients with primary invasive squamous cell carcinoma of the vagina (stage I through IVa), a radical irradiation was planned in 18 and a palliative in the remaining 4 patients. The 5-year survival rate, in the radically irradiated patients, was 10/18 for all stages, and 8/13 for patients of stage I. A vaginal boost irradiation did not seem to improve the results of external irradiation in patients of stage I. Severe adverse effects did not occur.

  5. Analytic continuation of dual Feynman amplitudes

    International Nuclear Information System (INIS)

    Bleher, P.M.

    1981-01-01

    A notion of dual Feynman amplitude is introduced and a theorem on the existence of analytic continuation of this amplitude from the convergence domain to the whole complex is proved. The case under consideration corresponds to massless power propagators and the analytic continuation is constructed on the propagators powers. Analytic continuation poles and singular set of external impulses are found explicitly. The proof of the theorem on the existence of analytic continuation is based on the introduction of α-representation for dual Feynman amplitudes. In proving, the so-called ''trees formula'' and ''trees-with-cycles formula'' are established that are dual by formulation to the trees and 2-trees formulae for usual Feynman amplitudes. (Auth.)

  6. Amplitude-Integrated EEG in the Newborn

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2008-11-01

    Full Text Available Th value of amplitude-integrated electroencephalography (aEEG in the newborn is explored by researchers at Washington University, St Louis; Wilhelmina Children’s Hospital, Utrecht, Netherlands; and Uppsala University Hospital, Sweden.

  7. Effective string theory and QCD scattering amplitudes

    International Nuclear Information System (INIS)

    Makeenko, Yuri

    2011-01-01

    QCD string is formed at distances larger than the confinement scale and can be described by the Polchinski-Strominger effective string theory with a nonpolynomial action, which has nevertheless a well-defined semiclassical expansion around a long-string ground state. We utilize modern ideas about the Wilson-loop/scattering-amplitude duality to calculate scattering amplitudes and show that the expansion parameter in the effective string theory is small in the Regge kinematical regime. For the amplitudes we obtain the Regge behavior with a linear trajectory of the intercept (d-2)/24 in d dimensions, which is computed semiclassically as a momentum-space Luescher term, and discuss an application to meson scattering amplitudes in QCD.

  8. Scattering Amplitudes via Algebraic Geometry Methods

    CERN Document Server

    Søgaard, Mads; Damgaard, Poul Henrik

    This thesis describes recent progress in the understanding of the mathematical structure of scattering amplitudes in quantum field theory. The primary purpose is to develop an enhanced analytic framework for computing multiloop scattering amplitudes in generic gauge theories including QCD without Feynman diagrams. The study of multiloop scattering amplitudes is crucial for the new era of precision phenomenology at the Large Hadron Collider (LHC) at CERN. Loop-level scattering amplitudes can be reduced to a basis of linearly independent integrals whose coefficients are extracted from generalized unitarity cuts. We take advantage of principles from algebraic geometry in order to extend the notion of maximal cuts to a large class of two- and three-loop integrals. This allows us to derive unique and surprisingly compact formulae for the coefficients of the basis integrals. Our results are expressed in terms of certain linear combinations of multivariate residues and elliptic integrals computed from products of ...

  9. Effective gluon interactions from superstring disk amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Oprisa, D.

    2006-05-15

    In this thesis an efficient method for the calculation of the N-point tree-level string amplitudes is presented. Furthermore it is shown that the six-gluon open-superstring disk amplitude can be expressed by a basis of six triple hypergeometric functions, which encode the full {alpha}' dependence. In this connection material for obtaining the {alpha}' expansion of these functions is derived. Hereby many Euler-Zagier sums are calculated including multiple harmonic series. (HSI)

  10. Effective gluon interactions from superstring disk amplitudes

    International Nuclear Information System (INIS)

    Oprisa, D.

    2006-05-01

    In this thesis an efficient method for the calculation of the N-point tree-level string amplitudes is presented. Furthermore it is shown that the six-gluon open-superstring disk amplitude can be expressed by a basis of six triple hypergeometric functions, which encode the full α' dependence. In this connection material for obtaining the α' expansion of these functions is derived. Hereby many Euler-Zagier sums are calculated including multiple harmonic series. (HSI)

  11. Employing helicity amplitudes for resummation in SCET

    International Nuclear Information System (INIS)

    Moult, Ian; Stewart, Iain W.; Tackmann, Frank J.; Waalewijn, Wouter J.; Nikhef, Amsterdam

    2016-05-01

    Helicity amplitudes are the fundamental ingredients of many QCD calculations for multi-leg processes. We describe how these can seamlessly be combined with resummation in Soft-Collinear Effective Theory (SCET), by constructing a helicity operator basis for which the Wilson coefficients are directly given in terms of color-ordered helicity amplitudes. This basis is crossing symmetric and has simple transformation properties under discrete symmetries.

  12. The amplitude of quantum field theory

    International Nuclear Information System (INIS)

    Medvedev, B.V.; Pavlov, V.P.; Polivanov, M.K.; Sukhanov, A.D.

    1989-01-01

    General properties of the transition amplitude in axiomatic quantum field theory are discussed. Bogolyubov's axiomatic method is chosen as the variant of the theory. The axioms of this method are analyzed. In particular, the significance of the off-shell extension and of the various forms of the causality condition are examined. A complete proof is given of the existence of a single analytic function whose boundary values are the amplitudes of all channels of a process with given particle number

  13. The Cepheid bump progression and amplitude equations

    International Nuclear Information System (INIS)

    Kovacs, G.; Buchler, J.R.

    1989-01-01

    It is shown that the characteristic and systematic behavior of the low-order Fourier amplitudes and phases of hydrodynamically generated radial velocity and light curves of Cepheid model sequences is very well captured not only qualitatively but also quantitatively by the amplitude equation formalism. The 2:1 resonance between the fundamental and the second overtone plays an essential role in the behavior of the models 8 refs

  14. Large and small cells non-keratinizing epidermoid vaginal carcinoma

    International Nuclear Information System (INIS)

    Maso Anaya, Ofelia; Morales Larramendi, Maria Elena; Diaz Perez, Dolores

    2012-01-01

    Five case reports of patients who were assisted at the cervix Pathology Department from 'Mariana Grajales Coello' Provincial Gynecological Obstetrical Hospital in Santiago de Cuba due to vaginal bleeding, low abdominal pain, leukorrhea and vaginal injuries are presented. The pathological study confirmed the diagnosis of squamous or epidermoid cells carcinoma

  15. Vaginal drug delivery systems: A Review of Current Status | Dobaria ...

    African Journals Online (AJOL)

    Among the various routes of drug delivery, the vaginal route offers many advantages due to its large permeation area, rich vascularization, avoidance of first pass metabolism and relatively low enzymatic activity. Several studies have shown that the vaginal cavity is an effective route for drug administration intended mainly ...

  16. Evaluation of vaginal implant transmitters in elk (Cervus elaphus nelsoni).

    Science.gov (United States)

    Bruce K. Johnson; Terrance McCoy; Christopher O. Kochanny; Rachel C. Cook

    2006-01-01

    The effects of vaginal implant transmitters for tissue damage after 11 wk in 13 captive adult elk (Cervus elaphus nelsoni) and subsequent reproductive performance in 38 free-ranging elk were evaluated. Vaginal implant transmitters are designed to be shed at parturition and are used to locate birth sites of wild ungulates; however, potential adverse...

  17. Prevalence of Vaginal Trichomoniasis: An Assessment of Sensitivity ...

    African Journals Online (AJOL)

    This study which was conducted on 400 females patients aged 15 to 60 years who complained of vaginal discharge and itching in some selected health centers in Yola between 2003 and March 2005, is a comparative study of the relative accuracies of three techniques for diagnosing vaginal trichomoniasis. Three sterile ...

  18. The stimulation of the vaginal immune system with short-term administration of a vaginal gel containing fraction of Propionibacterium acnes, hyaluronic acid and polycarbophil is efficacious in vaginal infections dependent on disorders in the vaginal ecosystem.

    Science.gov (United States)

    Melis, Gian Benedetto; Piras, Bruno; Marotto, Maria Francesca; Neri, Manuela; Corda, Valentina; Vallerino, Valerio; Saba, Alessandra; Lello, Stefano; Pilloni, Monica; Zedda, Pierina; Paoletti, Anna Maria; Mais, Valerio

    2018-04-12

    The vaginal immune system (VIS) is the first defense against antigens recognized as foreign. Substances capable of locally activating the VIS could be a valid strategy to treat vulvo-vaginal infections (VVI), caused by changes in the vaginal ecosystem, such as bacterial vaginosis (BV), vulvo-vaginal candidiasis (CA), and mixed vaginitis (MV). Bacterial lysates, obtained by crushing bacterial cultures, exert immuno-modulatory activities. The parietal fraction from Propionibacterium acnes is a patent of Depofarma (MoglianoVeneto, Italy). The preparation that associates such fraction to hyaluronic acid and polycarbophil is a registered trademark, commercially available in Italy as vaginal gel, Immunovag ® . The study aimed to evaluate whether a 5-day-treatment with Immunovag ® improves the symptoms and signs of VVI, in 60 women with Gardnerella vaginalis (GV), 154 with CA, 95 with MV, diagnosed with vulvar vaginal swab (VVS), and in 283 with BV, diagnosed with the Amsel criteria. At the end of the treatment (visit 2), the symptoms and signs of VVI disappeared in a significant number of subjects (χ 2 p < .02 vs pre-treatment) in all VVI groups, and their intensity was significantly (p < .0002) reduced in the subjects in which they were still present. Immunovag ® represents a valid treatment of VVI induced by changes in the vaginal ecosystem.

  19. [Physicopharmaceutical characteristics of ulinastatin vaginal suppositories prepared in a hospital].

    Science.gov (United States)

    Satake, Kiyoshi; Nakajima, Takanori; Iwata, Masanori; Fujikake, Yoshio; Kimura, Masayuki

    2011-01-01

    We studied a locally applied vaginal preparation (vaginal suppositories) of ulinastatin (urinary trypsin inhibitor, UTI), designed to threatened premature delivery and maintain pregnancy. Witepsol S55 was chosen as the basic component of the vaginal suppositories based on the physical pharmaceutical characteristics of three kinds of hard fats. The average particle size of the UTI aqueous injection was approximately 70% as compared with that of the UTI lyophilized product, used as the base material for the preparation of UTI vaginal suppositories. We compared the physical pharmaceutical properties of UTI vaginal suppositories with water contents of 2.5%, 5.0%, and 7.5%, respectively. Preparation strength negatively correlated with the water content. The coefficient of viscosity positively correlated with the water content of the preparation. UTI vaginal suppositories with a water content of 5.0% had the highest average drug release rate on moment analysis. A comprehensive evaluation of the properties of UTI vaginal suppositories, including high strength due to disintegration resistance, the coefficient of viscosity and its influence on local retention, and drug release and its influence on the duration of effect, indicated that a 5.0% UTI aqueous solution for injection combined with Witepsol S55 as the base was the optimal formulation for the hospital preparation of vaginal suppositories.

  20. Evaluation of vaginal pessary use by South African gynaecologists ...

    African Journals Online (AJOL)

    Introduction. The use of vaginal pessaries for conservative management of pelvic organ prolapse (POP) is well established. However, there are limited data on current clinical practice among gynaecologists, and the aim of this survey was therefore to evaluate vaginal pessary use among South African gynaecologists.

  1. Obstetric and gynecological diseases and complications resulting from vaginal dysbacteriosis.

    Science.gov (United States)

    Kovachev, Stefan Miladinov

    2014-08-01

    Accurate knowledge of the composition and ecology of vaginal microbial environment of a healthy woman is necessary for the understanding of normal flora and how to reduce the risk for diseases. Vagina and its microflora form a balanced ecosystem in which dominated bacteria are vaginal lactobacilli. There are dynamic changes in this ecosystem having structure and composition depending on many factors. The term dysbacteriosis defines any movement outside the normal range for the given biotope of obligate and/or facultative microflora. Such a change in the quantity and quality of the respective microbial balance is fraught with danger and requires correction and recovery. The purpose of this overview is to examine obstetric and gynecological diseases that can cause vaginal impaired microbial balance. Vaginal dysbacteriosis is a cause, predecessor, and often also consequence of vaginal infections. In essence, any vaginal infection can be seen as dysbacteriosis, developed to the most severe extent. Here, there is a dominant microorganism other than lactic acid bacteria in the vagina (clinically manifested or not, respectively), depletion of defense mechanisms of the vagina associated with the shift of lactobacilli from their dominant role in the vaginal balance, decrease in their number and species diversity, and a resulting change in the healthy status of the vagina. Vaginal dysbacteriosis can be found in pathogenetic mechanism, whereby many obstetric and gynecological diseases develop. Most of these diseases lead directly to increased maternal and infant morbidity and mortality, so it is important to understand the reasons for them and the arrangements for their prevention.

  2. Vaginal pH: Home-Use Tests

    Science.gov (United States)

    ... doesn't always mean that you have a vaginal infection. pH changes also do not help or differentiate ... of infection from another. Your doctor diagnoses a vaginal infection by using a combination of: pH, microscopic examination ...

  3. Sore throat · vaginal discharge · labial ulcer · Dx?

    Science.gov (United States)

    Caravelli, Ashley; Bhatnagar, Rupal; Ashaye, Adelola

    2016-06-01

    The patient complained of worsening vaginal pain and increased vaginal discharge, but reported resolution of her back and chest pain. She also said that a week earlier, she'd had a fever that reached 104° F and a sore throat. She denied urinary frequency/urgency, sexual activity, or sexual abuse.

  4. The threat of aerobic vaginitis to pregnancy and neonatal morbidity ...

    African Journals Online (AJOL)

    Aerobic vaginitis (AV) is an endogenous opportunistic infection brought about by the disruption of the normal vaginal microbiota. Its early diagnosis and treatment during pregnancy may reduce the risk of negative pregnancy outcomes. The aim of this review was to report on the aerobic bacteria most prevalent in AV and to ...

  5. Vaginal metastasis of pancreatic cancer | Benhayoune | Pan African ...

    African Journals Online (AJOL)

    Vaginal metastasis from pancreatic cancer is an extreme case and often indicates a poor prognosis. We present a case of pancreatic carcinoma with metastasis to the vagina that was discovered by vaginal bleeding. To our knowledge, this is the third case in the world of a primary pancreatic adenocarcinoma discovered of ...

  6. huge abdominal mass secondary to a transverse vaginal septum ...

    African Journals Online (AJOL)

    2011-12-01

    Dec 1, 2011 ... A diagnosis of Transverse Vaginal septum with prob- able vaginal atresia was made. A two-stage surgery was planned: laparotomy to drain the haemorrhagic ... through a low vertical uterine incision. A probe passed through the uterine incision towards the cervix ended blindly. The tubes were distended ...

  7. Paediatric vaginal discharge | Makwela | South African Family Practice

    African Journals Online (AJOL)

    Vaginal discharge in the prepubertal patient is a common symptom, and can be a source of distress for the caregiver and concern for the healthcare worker. Several factors predispose these patients to the development of recurrent vaginal discharge. Unless noticed by the caregiver, this problem can persist for long periods ...

  8. Life threatening vaginal haemorrhage from coital laceration in a post ...

    African Journals Online (AJOL)

    Case report: A 55-year-old woman who presented as an emergency with haemorrhagic shock following vaginal bleeding from consensual coitus is presented. She was resuscitated with intravenous fluids and blood transfusions. The vaginal laceration of about 5 cm on the right side of the posterior fornix was sutured ...

  9. Square pulse linear transformer driver

    Directory of Open Access Journals (Sweden)

    A. A. Kim

    2012-04-01

    Full Text Available The linear transformer driver (LTD technological approach can result in relatively compact devices that can deliver fast, high current, and high-voltage pulses straight out of the LTD cavity without any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The usual LTD architecture [A. A. Kim, M. G. Mazarakis, V. A. Sinebryukhov, B. M. Kovalchuk, V. A. Vizir, S. N Volkov, F. Bayol, A. N. Bastrikov, V. G. Durakov, S. V. Frolov, V. M. Alexeenko, D. H. McDaniel, W. E. Fowler, K. LeCheen, C. Olson, W. A. Stygar, K. W. Struve, J. Porter, and R. M. Gilgenbach, Phys. Rev. ST Accel. Beams 12, 050402 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050402; M. G. Mazarakis, W. E. Fowler, A. A. Kim, V. A. Sinebryukhov, S. T. Rogowski, R. A. Sharpe, D. H. McDaniel, C. L. Olson, J. L. Porter, K. W. Struve, W. A. Stygar, and J. R. Woodworth, Phys. Rev. ST Accel. Beams 12, 050401 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050401] provides sine shaped output pulses that may not be well suited for some applications like z-pinch drivers, flash radiography, high power microwaves, etc. A more suitable power pulse would have a flat or trapezoidal (rising or falling top. In this paper, we present the design and first test results of an LTD cavity that generates such a type of output pulse by including within its circular array a number of third harmonic bricks in addition to the main bricks. A voltage adder made out of a square pulse cavity linear array will produce the same shape output pulses provided that the timing of each cavity is synchronized with the propagation of the electromagnetic pulse.

  10. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  11. Pulse radiolysis

    International Nuclear Information System (INIS)

    Greenshields, H.; Seddon, W.A.

    1982-03-01

    This supplement to two bibliographies published in 1970 and 1972 lists 734 references to the literature of pulse radiolysis, arranged under eight broad subject headings. The references were compiled by searching Biological Abstracts, Chemical Abstracts, Nuclear Science Abstracts and the Weekly List of Papers in Radiation Chemistry issued by the Radiation Chemistry Data Center of Notre Dame University. Full bibliographic data is given for papers published in the period 1971 to 1974. A personal author index listing more than 600 authors and a similar number of co-authors is included

  12. Ablative dual-phase Erbium:YAG laser treatment of atrophy-related vaginal symptoms in post-menopausal breast cancer survivors omitting hormonal treatment.

    Science.gov (United States)

    Mothes, A R; Runnebaum, M; Runnebaum, I B

    2018-05-01

    First evaluation of dual-phase vaginal Er:YAG laser to omit hormonal treatment for atrophy-related symptoms in post-menopausal breast cancer survivors following prolapse surgery. Patients with a history of breast cancer at the time of surgery for pelvic organ prolapse were offered non-hormonal vaginal Er:YAG laser treatment when complaining of atrophy-related genitourinary syndrome of menopause. A single 10-min course of dual-phase protocol of pulsed Er:YAG laser (2940 nm, fractional ablative and thermal mode, fluence according to tissue thickness). Follow-up included subjective satisfaction, vaginal pH, vaginal health index (VHI), and complications after 6 weeks. A total of 16 breast cancer survivors (age 71 years, SD 7) had been seeking treatment for pelvic floor symptoms related to vaginal atrophy at follow-up visits after prolapse surgery. All ablative vaginal Er:YAG laser outpatient procedures were successfully completed, all patients returned to daily activities without a need for analgetic medication. Evaluation was performed after 8.3 (SD 2.5) weeks. Pre-laser VHI scored 16 (SD 4.6) and post-laser VHI 20 (SD 3) with p = 0.01. Patients were satisfied in 94% (n = 15) regarding symptom relief. Breast cancer survivors with atrophy-related complaints after pelvic floor surgery may benefit from vaginal application of this innovative dual protocol of Er:YAG laser technology as a non-hormonal treatment approach.

  13. Experimental Investigation of Propagation and Reflection Phenomena in Finite Amplitude Sound Beams.

    Science.gov (United States)

    Averkiou, Michalakis Andrea

    Measurements of finite amplitude sound beams are compared with theoretical predictions based on the KZK equation. Attention is devoted to harmonic generation and shock formation related to a variety of propagation and reflection phenomena. Both focused and unfocused piston sources were used in the experiments. The nominal source parameters are piston radii of 6-25 mm, frequencies of 1-5 MHz, and focal lengths of 10-20 cm. The research may be divided into two parts: propagation and reflection of continuous-wave focused sound beams, and propagation of pulsed sound beams. In the first part, measurements of propagation curves and beam patterns of focused pistons in water, both in the free field and following reflection from curved targets, are presented. The measurements are compared with predictions from a computer model that solves the KZK equation in the frequency domain. A novel method for using focused beams to measure target curvature is developed. In the second part, measurements of pulsed sound beams from plane pistons in both water and glycerin are presented. Very short pulses (less than 2 cycles), tone bursts (5-30 cycles), and frequency modulated (FM) pulses (10-30 cycles) were measured. Acoustic saturation of pulse propagation in water is investigated. Self-demodulation of tone bursts and FM pulses was measured in glycerin, both in the near and far fields, on and off axis. All pulse measurements are compared with numerical results from a computer code that solves the KZK equation in the time domain. A quasilinear analytical solution for the entire axial field of a self-demodulating pulse is derived in the limit of strong absorption. Taken as a whole, the measurements provide a broad data base for sound beams of finite amplitude. Overall, outstanding agreement is obtained between theory and experiment.

  14. The use of supersaturation for the vaginal application of microbicides

    DEFF Research Database (Denmark)

    Grammen, Carolien; Plum, Jakob; Van Den Brande, Jeroen

    2014-01-01

    In this study, we investigated the potential of supersaturation for the formulation of the poorly water-soluble microbicide dapivirine (DPV) in an aqueous vaginal gel in order to enhance its vaginal tissue uptake. Different excipients such as hydroxypropylmethylcellulose, polyethylene glycol 1000....... The best performing supersaturated gel containing 500 μM DPV (supersaturation degree of 4) in the presence of sulfobutyl ether-beta-cyclodextrin (2.5%) appeared to be stable for at least 3 months. In addition, the gel generated a significant increase in vaginal drug uptake in rabbits as compared...... with suspension gels. We conclude that supersaturation is a possible strategy to enhance the vaginal concentration of hydrophobic microbicides, thereby increasing permeation into the vaginal submucosa....

  15. [Vaginal birth after cesarean section in light of international opinions].

    Science.gov (United States)

    Németh, Gábor; Molnár, András

    2017-07-01

    The tendency of increasing cesarean section rate has drawn worldwide attention. The vaginal birth after cesarean section is a useful method to decrease cesarean section rate at defined cases. Retrospective overview of factors resulting successful vaginal birth, labor/induction's condition, criterias, short and long term benefits and consequences. Overview recommendations of international guidelines and publications' results concerned vaginal birth after cesarean section in "PubMed", "MEDLINE", "Cochrane" databases from 1996 to 2016. Reviewing results of recommendations and publications we can declare that statements are inconsistent, however the option of vaginal birth after cesarean section is appropriate for decrease complications and trend of increasing cesarean section rate. It would be important in our country to define a uniform recommendation regarding vaginal birth after cesarean section, with supporting evidence in obstetrical and gynecological practice. Orv Hetil. 2017; 158(30): 1168-1174.

  16. Aerobic vaginitis: no longer a stranger.

    Science.gov (United States)

    Donders, Gilbert G G; Bellen, Gert; Grinceviciene, Svitrigaile; Ruban, Kateryna; Vieira-Baptista, Pedro

    Aerobic vaginitis (AV) is the name given in 2002 to a vaginal infectious entity which was not recognized as such before. It is characterized by abnormal (dysbiotic) vaginal microflora containing aerobic, enteric bacteria, variable levels of vaginal inflammation and deficient epithelial maturation. Although AV and bacterial vaginosis (BV) share some characteristics, such as a diminished number or absence of lactobacilli, increased discharge (fishy smelling in BV, while in severe forms of AV, a foul, rather rotten smell may be present) and increased pH (often more pronounced in AV), there are also striking differences between the two. There is no inflammation in women with BV, whereas the vagina of women with AV often appears red and edematous, and may even display small erosions or ulcerations. The color of the discharge in BV is usually whitish or gray and of a watery consistency, whereas in AV it is yellow to green and rather thick and mucoid. Women with BV do not have dyspareunia, while some women with severe AV do. Finally, the microscopic appearance differs in various aspects, such as the presence of leucocytes and parabasal or immature epithelial cells in AV and the absence of the granular aspect of the microflora, typical of BV. Despite all these differences, the distinction between AV and BV was not recognized in many former studies, leading to incomplete and imprecise diagnostic workouts and erroneous management of patients in both clinical and research settings. The prevalence of AV ranges between 7 and 12%, and is therefore less prevalent than BV. Although still largely undiagnosed, many researchers and clinicians increasingly take it into account as a cause of symptomatic vaginitis. AV can co-occur with other entities, such as BV and candidiasis. It can be associated with dyspareunia, sexually transmitted infections (such as human papilloma virus, human immunodeficiency virus, Trichomonas vaginalis and Chlamydia trachomatis), chorioamnionitis, fetal

  17. Pulse pile-up. I: Short pulses

    International Nuclear Information System (INIS)

    Wilkinson, D.H.

    1990-07-01

    The search for rare large pulses against an intense background of smaller ones involves consideration of pulse pile-up. Approximate methods are presented, based on ruin theory, by which the probability of such pile-up may be estimated for pulses of arbitrary form and of arbitrary pulse-height distribution. These methods are checked against cases for which exact solutions are available. The present paper is concerned chiefly with short pulses of finite total duration. (Author) (5 refs., 24 figs.)

  18. Sound Beams with Shockwave Pulses

    Science.gov (United States)

    Enflo, B. O.

    2000-11-01

    The beam equation for a sound beam in a diffusive medium, called the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation, has a class of solutions, which are power series in the transverse variable with the terms given by a solution of a generalized Burgers’ equation. A free parameter in this generalized Burgers’ equation can be chosen so that the equation describes an N-wave which does not decay. If the beam source has the form of a spherical cap, then a beam with a preserved shock can be prepared. This is done by satisfying an inequality containing the spherical radius, the N-wave pulse duration, the N-wave pulse amplitude, and the sound velocity in the fluid.

  19. Acceptability of the vaginal contraceptive ring among adolescent women.

    Science.gov (United States)

    Terrell, Lekeisha R; Tanner, Amanda E; Hensel, Devon J; Blythe, Margaret J; Fortenberry, J Dennis

    2011-08-01

    Although underutilized, the vaginal contraceptive ring has several advantages over other contraceptive methods that could benefit adolescents. We examined factors that may influence willingness to try the vaginal ring including: sexual and contraceptive history, genital comfort, and vaginal ring characteristics. Cross sectional Midwestern adolescent health clinics Adolescent women (N = 200; 14-18 years; 89% African-American) INTERVENTIONS/MAIN OUTCOME MEASURES: All participants received education about the vaginal ring and viewed pictures demonstrating insertion; they then completed a visual/audio computer-assisted self interview. The primary outcome variable, willingness to try the vaginal ring, was a single Likert-scale item. Over half the participants reported knowledge of the vaginal ring with healthcare providers identified as the most important source of contraceptive information. Comfort with one's genitals, insertion and removal, using alternative methods of insertion, and knowing positive method characteristics were significantly associated with willingness to try the vaginal ring. A decreased willingness to try the vaginal ring was related to concerns of the ring getting lost inside or falling out of the vagina. Willingness to try the ring was associated with positive feelings about genitals (e.g., comfort with appearance, hygiene, function). Thus, to increase willingness to try the vaginal ring among adolescents, providers should make it common practice to discuss basic female reproductive anatomy, raise awareness about female genital health and address concerns about their genitals. Providers can offer alternative insertion techniques (e.g., gloves) to make use more accessible. These strategies may increase vaginal ring use among adolescents. 2011 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  20. Beneficial effects of a Coriolus versicolor-based vaginal gel on cervical epithelization, vaginal microbiota and vaginal health: a pilot study in asymptomatic women.

    Science.gov (United States)

    Palacios, Santiago; Losa, Fernando; Dexeus, Damián; Cortés, Javier

    2017-03-16

    To assess the effect of a 12-day treatment using a vaginal gel based on niosomes containing hyaluronic acid, ß-glucan, alpha-glucan oligosaccharide, Coriolus versicolor, Asian centella, Azadirachta indica and Aloe vera on vaginal microbiota, cervical epithelization and vaginal health. Open-label, prospective pilot study conducted in asymptomatic women in daily practice. Cervical epithelization was evaluated by colposcopy using an ectopy epithelization score (from 5: no ectopy to 1: severe ectopy and bleeding), vaginal microbiota using the VaginaStatus-Diagnostic test (Instiüt für Mikroökologie, Herborn, Germany) and further rated by the investigator using a 5-point Liker scale (from 5: normal to 1: very severe deterioration in which all evaluated species were altered), and vaginal health using the Vaginal Health Index. In 21 women, a positive effect to improve epithelization of the cervical mucosa, with a mean score of 4.42 at the final visit as compared to 3.09 at baseline (P vaginal microbiota status, with a mean score of 4.0 at the final visit vs. 3.3 at baseline (P = NS) (21.2% improvement). In 11 women, the Vaginal Health Index increased from 19.0 at baseline to 22.3 at the final visit (P = 0.007). The concentration of Lactobacillus spp. increased 54.5% of women and pH decreased from 4.32 to 4.09. These encouraging preliminary results provide the basis for designing a randomized controlled study, and for potential use in human papilloma virus infection. ISRCTN77955077 . Registration date: February 15, 2017. Retrospectively registered.