WorldWideScience

Sample records for vacuum scanning electron

  1. Vacuum electronics

    CERN Document Server

    Eichmeier, Joseph A

    2008-01-01

    Nineteen experts from the electronics industry, research institutes and universities have joined forces to prepare this book. ""Vacuum Electronics"" covers the electrophysical fundamentals, the present state of the art and applications, as well as the future prospects of microwave tubes and systems, optoelectronics vacuum devices, electron and ion beam devices, light and X-ray emitters, particle accelerators and vacuum interrupters. These topics are supplemented by useful information about the materials and technologies of vacuum electronics and vacuum technology.

  2. Observation of Live Ticks (Haemaphysalis flava) by Scanning Electron Microscopy under High Vacuum Pressure

    Science.gov (United States)

    Ishigaki, Yasuhito; Nakamura, Yuka; Oikawa, Yosaburo; Yano, Yasuhiro; Kuwabata, Susumu; Nakagawa, Hideaki; Tomosugi, Naohisa; Takegami, Tsutomu

    2012-01-01

    Scanning electron microscopes (SEM), which image sample surfaces by scanning with an electron beam, are widely used for steric observations of resting samples in basic and applied biology. Various conventional methods exist for SEM sample preparation. However, conventional SEM is not a good tool to observe living organisms because of the associated exposure to high vacuum pressure and electron beam radiation. Here we attempted SEM observations of live ticks. During 1.5×10−3 Pa vacuum pressure and electron beam irradiation with accelerated voltages (2–5 kV), many ticks remained alive and moved their legs. After 30-min observation, we removed the ticks from the SEM stage; they could walk actively under atmospheric pressure. When we tested 20 ticks (8 female adults and 12 nymphs), they survived for two days after SEM observation. These results indicate the resistance of ticks against SEM observation. Our second survival test showed that the electron beam, not vacuum conditions, results in tick death. Moreover, we describe the reaction of their legs to electron beam exposure. These findings open the new possibility of SEM observation of living organisms and showed the resistance of living ticks to vacuum condition in SEM. These data also indicate, for the first time, the usefulness of tick as a model system for biology under extreme condition. PMID:22431980

  3. Scanning Auger Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — A JEOL model 7830F field emission source, scanning Auger microscope.Specifications / Capabilities:Ultra-high vacuum (UHV), electron gun range from 0.1 kV to 25 kV,...

  4. Electronic “Edge” State on Molybdenite Basal Plane Observed by Ultrahigh-Vacuum Scanning Tunneling Microscopy and Spectroscopy

    Science.gov (United States)

    Komiyama, Masaharu; Tomita, Hiroyuki; Yoda, Eisuke

    2007-09-01

    An electronic state heretofore unreported has been found on a cleaved basal plane of a natural molybdenite (MoS2) single crystal by ultrahigh-vacuum scanning tunneling microscopy (UHV-STM), and examined in detail both by STM and scanning tunneling spectroscopy (STS). The new electronic state resides on the edge of the upper terrace of MoS2(0001), manifesting itself in the form of bright ridges with a width of ca. 4 nm along the step edges in negatively sample-biased STM images. This ridge structure is nonexistent in STM images taken with positive sample biases. STS showed that the local density of states (LDOS) on such ridge structures is much higher than that on the terraces in the range of 0.2-1.2 eV below the Fermi edge. The nature and origin of this high LDOS at the step edges are discussed.

  5. Comparative analysis of Trichuris muris surface using conventional, low vacuum, environmental and field emission scanning electron microscopy.

    Science.gov (United States)

    Lopes Torres, Eduardo José; de Souza, Wanderley; Miranda, Kildare

    2013-09-23

    The whipworm of the genus Trichuris Roederer, 1791, is a nematode of worldwide distribution and comprises species that parasitize humans and other mammals. Infections caused by Trichuris spp. in mammals can lead to various intestinal diseases of human and veterinary interest. The morphology of Trichuris spp. and other helminths has been mostly studied using conventional scanning electron microscopy of chemically fixed, dried and metal-coated specimens, although this kind of preparation has been shown to introduce a variety of artifacts such as sample shrinking, loss of secreted products and/or hiding of small structures due to sample coating. Low vacuum (LVSEM) and environmental scanning electron microscopy (ESEM) have been applied to a variety of insulator samples, also used in the visualization of hydrated and/or live specimens in their native state. In the present work, we used LVSEM and ESEM to analyze the surface of T. muris and analyze its interaction with the host tissue using freshly fixed or unfixed hydrated samples. Analysis of hydrated samples showed a set of new features on the surface of the parasite and the host tissue, including the presence of the secretory products of the bacillary glands on the surface of the parasite, and the presence of mucous material and eggs on the intestinal surface. Field emission scanning electron microscopy (FESEM) was also applied to reveal the detailed structure of the glandular chambers in fixed, dried and metal coated samples. Taken together, the results show that analysis of hydrated samples may provide new insights in the structural organization of the surface of helminth parasites and its interaction with the infected tissue, suggesting that the application of alternative SEM techniques may open new perspectives for analysis in taxonomy, morphology and host-parasite interaction fields. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Comparative analysis of Trichuris muris surface using conventional, low vacuum, environmental and field emission scanning electron microscopy

    National Research Council Canada - National Science Library

    Lopes Torres, Eduardo José; de Souza, Wanderley; Miranda, Kildare

    2013-01-01

    .... The morphology of Trichuris spp. and other helminths has been mostly studied using conventional scanning electron microscopy of chemically fixed, dried and metal-coated specimens, although this kind of preparation has been shown...

  7. A modified ‘NanoSuit®’ preserves wet samples in high vacuum: direct observations on cells and tissues in field-emission scanning electron microscopy

    Science.gov (United States)

    Takaku, Yasuharu; Suzuki, Hiroshi; Kawasaki, Hideya; Ohta, Isao; Ishii, Daisuke; Hirakawa, Satoshi; Tsutsui, Takami; Matsumoto, Haruko; Takehara, Sayuri; Nakane, Chinatsu; Sakaida, Kana; Suzuki, Chiaki; Muranaka, Yoshinori; Kikuchi, Hirotoshi; Konno, Hiroyuki; Shimomura, Masatsugu

    2017-01-01

    Although field-emission scanning electron microscopy (FE-SEM) has proven very useful in biomedical research, the high vacuum required (10−3 to 10−7 Pa) precludes direct observations of living cells and tissues at high resolution and often produces unwanted structural changes. We have previously described a method that allows the investigator to keep a variety of insect larvae alive in the high vacuum environment of the electron microscope by encasing the organisms in a thin, vacuum-proof suit, the ‘NanoSuit®'. However, it was impossible to protect wet tissues freshly excised from intact organisms or cultured cells. Here we describe an improved ‘NanoSuit' technique to overcome this limitation. We protected the specimens with a surface shield enhancer (SSE) solution that consists of glycerine and electrolytes and found that the fine structure of the SSE-treated specimens is superior to that of conventionally prepared specimens. The SSE-based NanoSuit affords a much stronger barrier to gas and/or liquid loss than the previous NanoSuit did and, since it allows more detailed images, it could significantly help to elucidate the ‘real' organization of cells and their functions. PMID:28405375

  8. A modified 'NanoSuit®' preserves wet samples in high vacuum: direct observations on cells and tissues in field-emission scanning electron microscopy.

    Science.gov (United States)

    Takaku, Yasuharu; Suzuki, Hiroshi; Kawasaki, Hideya; Ohta, Isao; Ishii, Daisuke; Hirakawa, Satoshi; Tsutsui, Takami; Matsumoto, Haruko; Takehara, Sayuri; Nakane, Chinatsu; Sakaida, Kana; Suzuki, Chiaki; Muranaka, Yoshinori; Kikuchi, Hirotoshi; Konno, Hiroyuki; Shimomura, Masatsugu; Hariyama, Takahiko

    2017-03-01

    Although field-emission scanning electron microscopy (FE-SEM) has proven very useful in biomedical research, the high vacuum required (10-3 to 10-7 Pa) precludes direct observations of living cells and tissues at high resolution and often produces unwanted structural changes. We have previously described a method that allows the investigator to keep a variety of insect larvae alive in the high vacuum environment of the electron microscope by encasing the organisms in a thin, vacuum-proof suit, the 'NanoSuit®'. However, it was impossible to protect wet tissues freshly excised from intact organisms or cultured cells. Here we describe an improved 'NanoSuit' technique to overcome this limitation. We protected the specimens with a surface shield enhancer (SSE) solution that consists of glycerine and electrolytes and found that the fine structure of the SSE-treated specimens is superior to that of conventionally prepared specimens. The SSE-based NanoSuit affords a much stronger barrier to gas and/or liquid loss than the previous NanoSuit did and, since it allows more detailed images, it could significantly help to elucidate the 'real' organization of cells and their functions.

  9. Vacuum scanning capillary photoemission microscopy

    DEFF Research Database (Denmark)

    Aseyev, S.A.; Cherkun, A P; Mironov, B N

    2017-01-01

    We demonstrate the use of a conical capillary in a scanning probe microscopy for surface analysis. The probe can measure photoemission from a substrate by transmitting photoelectrons along the capillary as a function of probe position. The technique is demonstrated on a model substrate consisting...

  10. Microscale Digital Vacuum Electronic Gates

    Science.gov (United States)

    Manohara, Harish (Inventor); Mojarradi, Mohammed M. (Inventor)

    2014-01-01

    Systems and methods in accordance with embodiments of the invention implement microscale digital vacuum electronic gates. In one embodiment, a microscale digital vacuum electronic gate includes: a microscale field emitter that can emit electrons and that is a microscale cathode; and a microscale anode; where the microscale field emitter and the microscale anode are disposed within at least a partial vacuum; where the microscale field emitter and the microscale anode are separated by a gap; and where the potential difference between the microscale field emitter and the microscale anode is controllable such that the flow of electrons between the microscale field emitter and the microscale anode is thereby controllable; where when the microscale anode receives a flow of electrons, a first logic state is defined; and where when the microscale anode does not receive a flow of electrons, a second logic state is defined.

  11. Scanning transmission electron microscope

    NARCIS (Netherlands)

    Kruit, P.

    2006-01-01

    The invention relates to a scanning transmission electron microscope comprising an electron source, an electron accelerator and deflection means for directing electrons emitted by the electron source at an object to be examined, and in addition a detector for detecting electrons coming from the

  12. Scanning transmission electron microscope

    OpenAIRE

    Kruit, P.

    2006-01-01

    The invention relates to a scanning transmission electron microscope comprising an electron source, an electron accelerator and deflection means for directing electrons emitted by the electron source at an object to be examined, and in addition a detector for detecting electrons coming from the object and, connected to the detector, a device for processing the detected electrons so as to form an object image, wherein a beam splitter is provided for dividing the electron beam from the electron...

  13. Scanning ultrafast electron microscopy

    OpenAIRE

    Yang, Ding-Shyue; Mohammed, Omar F.; Zewail, Ahmed H.

    2010-01-01

    Progress has been made in the development of four-dimensional ultrafast electron microscopy, which enables space-time imaging of structural dynamics in the condensed phase. In ultrafast electron microscopy, the electrons are accelerated, typically to 200 keV, and the microscope operates in the transmission mode. Here, we report the development of scanning ultrafast electron microscopy using a field-emission-source configuration. Scanning of pulses is made in the single-electron mode, for whic...

  14. Vacuum electronics applications at CERN

    CERN Document Server

    Jensen, E

    2009-01-01

    CERN operates a large number of vacuum electronics based RF power amplifiers covering a wide frequency range – over 300 sockets with 24 different grid tubes and klystrons are in use and require constant care to insure reliable operation of the accelerators. This is in particular true for the LHC and its injector chain, for which a program of improvement and stepwise upgrade has started. These include IOT’s for the SPS and klystrons and modulators for Linac4 and SPL. The CLIC study and the CTF3 facility are relevant to vacuum electronics in many ways: The CLIC primary RF power, to be provided at 1 GHz, requires highest possible efficiency and phase stability, MBK’s are likely candidates. The CLIC RF power source and CTF3 are themselves large vacuum electronics applications, consequently there are areas of common interest and concern, including fabrication techniques, pulse compression techniques, breakdown and multipactor theory and simulation, material fatigue, numerical analysis of slow-wave structures...

  15. Scanning ultrafast electron microscopy.

    Science.gov (United States)

    Yang, Ding-Shyue; Mohammed, Omar F; Zewail, Ahmed H

    2010-08-24

    Progress has been made in the development of four-dimensional ultrafast electron microscopy, which enables space-time imaging of structural dynamics in the condensed phase. In ultrafast electron microscopy, the electrons are accelerated, typically to 200 keV, and the microscope operates in the transmission mode. Here, we report the development of scanning ultrafast electron microscopy using a field-emission-source configuration. Scanning of pulses is made in the single-electron mode, for which the pulse contains at most one or a few electrons, thus achieving imaging without the space-charge effect between electrons, and still in ten(s) of seconds. For imaging, the secondary electrons from surface structures are detected, as demonstrated here for material surfaces and biological specimens. By recording backscattered electrons, diffraction patterns from single crystals were also obtained. Scanning pulsed-electron microscopy with the acquired spatiotemporal resolutions, and its efficient heat-dissipation feature, is now poised to provide in situ 4D imaging and with environmental capability.

  16. The Dirac-Electron Vacuum Wave

    Directory of Open Access Journals (Sweden)

    Daywitt W. C.

    2016-07-01

    Full Text Available This paper argues that the Dirac equation can be interpreted as an interaction between the electron core and the Planck vacuum state, where the positive and negative solutions represent respectively the dynamics of the electron core and a vacuum wave propagating within the vacuum state. Results show that the nonrelativistic positive solution reduces to the Schrödinger wave equation

  17. Scanning electron microscopy of bone.

    Science.gov (United States)

    Boyde, Alan

    2012-01-01

    This chapter described methods for Scanning Electron Microscopical imaging of bone and bone cells. Backscattered electron (BSE) imaging is by far the most useful in the bone field, followed by secondary electrons (SE) and the energy dispersive X-ray (EDX) analytical modes. This chapter considers preparing and imaging samples of unembedded bone having 3D detail in a 3D surface, topography-free, polished or micromilled, resin-embedded block surfaces, and resin casts of space in bone matrix. The chapter considers methods for fixation, drying, looking at undersides of bone cells, and coating. Maceration with alkaline bacterial pronase, hypochlorite, hydrogen peroxide, and sodium or potassium hydroxide to remove cells and unmineralised matrix is described in detail. Attention is given especially to methods for 3D BSE SEM imaging of bone samples and recommendations for the types of resin embedding of bone for BSE imaging are given. Correlated confocal and SEM imaging of PMMA-embedded bone requires the use of glycerol to coverslip. Cathodoluminescence (CL) mode SEM imaging is an alternative for visualising fluorescent mineralising front labels such as calcein and tetracyclines. Making spatial casts from PMMA or other resin embedded samples is an important use of this material. Correlation with other imaging means, including microradiography and microtomography is important. Shipping wet bone samples between labs is best done in glycerol. Environmental SEM (ESEM, controlled vacuum mode) is valuable in eliminating -"charging" problems which are common with complex, cancellous bone samples.

  18. Suprathermal electrons in a vacuum spark discharge

    Energy Technology Data Exchange (ETDEWEB)

    Bashutin, O. A., E-mail: boa308@mail.ru; Savjolov, A. S., E-mail: savjolov@plasma.mephi.ru [National Research Nuclear University MEPhI (Russian Federation)

    2016-04-15

    Results of experiments on the detection of suprathermal electron beams in the plasma of a highcurrent low-inductance vacuum spark by means of space-resolved spectral X-ray polarimetry are presented. It is shown that the observed polarization of bremsstrahlung may be caused by an ~100-keV electron beam propagating along the discharge axis from the pinching region toward the anode. The influence of the discharge initiation conditions on the parameters of the generated electron beams is analyzed.

  19. Ex situ elaborated proximity mesoscopic structures for ultrahigh vacuum scanning tunneling spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stolyarov, V. S. [UMR 7588, Institut des Nanosciences de Paris, UPMC Univ Paris 06, Sorbonne Universités, F-75005 Paris (France); CNRS, UMR 7588, Institut des Nanosciences de Paris, F-75005 Paris (France); Institute of Solid State Physics RAS, 142432 Chernogolovka (Russian Federation); Moscow Institute of Physics and Technology, 141700 Dolgoprudny (Russian Federation); Kazan Federal University, 420008 Kazan (Russian Federation); Moscow State University, 119991 Moscow (Russian Federation); Cren, T., E-mail: tristan.cren@upmc.fr; Debontridder, F.; Brun, C. [UMR 7588, Institut des Nanosciences de Paris, UPMC Univ Paris 06, Sorbonne Universités, F-75005 Paris (France); CNRS, UMR 7588, Institut des Nanosciences de Paris, F-75005 Paris (France); Veshchunov, I. S. [Université de Bordeaux, LP2N, 351 cours de la Libération, F-33405 Talence (France); Institute of Solid State Physics RAS, 142432 Chernogolovka (Russian Federation); Skryabina, O. V. [Institute of Solid State Physics RAS, 142432 Chernogolovka (Russian Federation); Rusanov, A. Yu. [LLC “Applied radiophysics” 142432 Chernogolovka (Russian Federation); Roditchev, D. [UMR 7588, Institut des Nanosciences de Paris, UPMC Univ Paris 06, Sorbonne Universités, F-75005 Paris (France); CNRS, UMR 7588, Institut des Nanosciences de Paris, F-75005 Paris (France); LPEM-UMR 8213, CNRS, ESPCI-ParisTech, UPMC, 10 rue Vauquelin, F-75005 Paris (France)

    2014-04-28

    We apply ultrahigh vacuum Scanning Tunneling Spectroscopy (STS) at ultra-low temperature to study proximity phenomena in metallic Cu in contact with superconducting Nb. In order to solve the problem of Cu-surface contamination, Cu(50 nm)/Nb(100 nm) structures are grown by respecting the inverted order of layers on SiO{sub 2}/Si substrate. Once transferred into vacuum, the samples are cleaved at the structure-substrate interface. As a result, a contamination-free Cu-surface is exposed in vacuum. It enables high-resolution STS of superconducting correlations induced by proximity from the underlying superconducting Nb layer. By applying magnetic field, we generate unusual proximity-induced superconducting vortices and map them with a high spatial and energy resolution. The suggested method opens a way to access local electronic properties of complex electronic mesoscopic devices by performing ex situ STS under ultrahigh vacuum.

  20. A fluorescence scanning electron microscope

    OpenAIRE

    Kanemaru, Takaaki; Hirata, Kazuho; Takasu, Shin-ichi; Isobe, Shin-Ichiro; Mizuki, Keiji; Mataka, Shuntaro; Nakamura, Kei-ichiro

    2010-01-01

    Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM) and an electron microscope (EM). In the current study, a scanning electron microscope (SEM) (JEOL JXA8600 M) was combined with a fluorescence digital c...

  1. Study on local vacuum electron beam welding of flange rim

    CERN Document Server

    He Cheng Dan; Ying Lei; Xu Qi Jin

    2002-01-01

    Local vacuum electron beam welding and its application prospect in military and civil industry are introduced. A home made local vacuum electron beam welding is completed. Its main technical parameters and key techniques are also presented

  2. Electronically-Scanned Pressure Sensors

    Science.gov (United States)

    Coe, C. F.; Parra, G. T.; Kauffman, R. C.

    1984-01-01

    Sensors not pneumatically switched. Electronic pressure-transducer scanning system constructed in modular form. Pressure transducer modules and analog to digital converter module small enough to fit within cavities of average-sized wind-tunnel models. All switching done electronically. Temperature controlled environment maintained within sensor modules so accuracy maintained while ambient temperature varies.

  3. The Tynode: A new vacuum electron multiplier

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Harry van der, E-mail: vdgraaf@nikhef.nl [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); Akhtar, Hassan; Budko, Neil; Chan, Hong Wah; Hagen, Cornelis W. [Delft University of Technology, Delft (Netherlands); Hansson, Conny C.T. [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); Nützel, Gert; Pinto, Serge D. [Photonis, Roden (Netherlands); Prodanović, Violeta; Raftari, Behrouz; Sarro, Pasqualina M. [Delft University of Technology, Delft (Netherlands); Sinsheimer, John; Smedley, John [Brookhaven National Laboratory, Upton, NY 11973 (United States); Tao, Shuxia [Eindhoven University of Technology/DIFFER (Netherlands); Theulings, Anne M.M.G. [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); Vuik, Kees [Delft University of Technology, Delft (Netherlands)

    2017-03-01

    By placing, in vacuum, a stack of transmission dynodes (tynodes) on top of a CMOS pixel chip, a single free electron detector could be made with outstanding performance in terms of spatial and time resolution. The essential object is the tynode: an ultra thin membrane, which emits, at the impact of an energetic electron on one side, a multiple of electrons at the other side. The electron yields of tynodes have been calculated by means of GEANT-4 Monte Carlo simulations, applying special low-energy extensions. The results are in line with another simulation based on a continuous charge-diffusion model. By means of Micro Electro Mechanical System (MEMS) technology, tynodes and test samples have been realized. The secondary electron yield of several samples has been measured in three different setups. Finally, several possibilities to improve the yield are presented.

  4. Physical electronics handbook of vacuum physics

    CERN Document Server

    Beck, A H

    2013-01-01

    Handbook of Vacuum Physics, Volume 2, Physical Electronics, discusses the fundamentals of electric discharges in gases. Electrical discharges in gases is used generically to denote the passage of electricity through a gas and implicitly embraces the wide variety of physical phenomena which accompany such a discharge of electricity. The discharge currents may be as small as 10-16A in certain ionization growth studies, or be as large as megamperes in thermonuclear and plasma physics studies. Key topics discussed include collision phenomena in gases; surface phenomena and transport of charged par

  5. New Vacuum Electronic Devices for Radar

    Directory of Open Access Journals (Sweden)

    Hu Yinfu

    2016-08-01

    Full Text Available Vacuum Electronic Devices (VEDs which are considered as the heart of a radar system, play an important role in their development. VEDs and radar systems supplement and promote each other. Some new trends in VEDs have been observed with advancements in the simulation tools for designing VEDs, new materials, new fabrication techniques. Recently, the performance of VEDs has greatly improved. In addition, new devices have been invented, which have laid the foundation for the developments of radar detection technology. This study introduces the recent development trends and research results of VEDs from microwave and millimeter wave devices and power modules, integrated VEDs, terahertz VEDs, and high power VEDs.

  6. UAVSAR Active Electronically Scanned Array

    Science.gov (United States)

    Sadowy, Gregory, A.; Chamberlain, Neil F.; Zawadzki, Mark S.; Brown, Kyle M.; Fisher, Charles D.; Figueroa, Harry S.; Hamilton, Gary A.; Jones, Cathleen E.; Vorperian, Vatche; Grando, Maurio B.

    2011-01-01

    The Uninhabited Airborne Vehicle Synthetic Aperture Radar (UAVSAR) is a pod-based, L-band (1.26 GHz), repeatpass, interferometric, synthetic aperture radar (InSAR) used for Earth science applications. Repeat-pass interferometric radar measurements from an airborne platform require an antenna that can be steered to maintain the same angle with respect to the flight track over a wide range of aircraft yaw angles. In order to be able to collect repeat-pass InSAR data over a wide range of wind conditions, UAVSAR employs an active electronically scanned array (AESA). During data collection, the UAVSAR flight software continuously reads the aircraft attitude state measured by the Embedded GPS/INS system (EGI) and electronically steers the beam so that it remains perpendicular to the flight track throughout the data collection

  7. Vacuum nanoelectronic devices novel electron sources and applications

    CERN Document Server

    Evtukh, Anatoliy; Yilmazoglu, Oktay; Mimura, Hidenori; Pavlidis, Dimitris

    2015-01-01

    Introducing up-to-date coverage of research in electron field emission from nanostructures, Vacuum Nanoelectronic Devices outlines the physics of quantum nanostructures, basic principles of electron field emission, and vacuum nanoelectronic devices operation, and offers as insight state-of-the-art and future researches and developments.  This book also evaluates the results of research and development of novel quantum electron sources that will determine the future development of vacuum nanoelectronics. Further to this, the influence of quantum mechanical effects on high frequency vacuum nanoelectronic devices is also assessed. Key features: In-depth description and analysis of the fundamentals of Quantum Electron effects in novel electron sources. Comprehensive and up-to-date summary of the physics and technologies for THz sources for students of physical and engineering specialties and electronics engineers. Unique coverage of quantum physical results for electron-field emission and novel electron sourc...

  8. Transmission environmental scanning electron microscope with scintillation gaseous detection device

    Energy Technology Data Exchange (ETDEWEB)

    Danilatos, Gerasimos, E-mail: gerry@danilatos.com [ESEM Research Laboratory, 28 Wallis Parade, North Bondi, NSW 2026 (Australia); Kollia, Mary [Laboratory of Electron Microscopy and Microanalysis, School of Natural Sciences, University of Patras, GR-26504 Patras (Greece); Dracopoulos, Vassileios [Foundation for Research & Technology-Hellas (FORTH), Institute of Chemical Engineering Sciences (ICE-HT), Stadiou Str., Platani P.O.Box 1414, GR-26504 Patras (Greece)

    2015-03-15

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. - Highlights: • Novel scanning transmission electron microscopy (STEM) with an environmental scanning electron microscope (ESEM) called TESEM. • Use of the gaseous detection device (GDD) in scintillation mode that allows high resolution bright and dark field imaging in the TESEM. • Novel approach towards a unification of both vacuum and environmental conditions in both bulk/surface and transmission mode of electron microscopy.

  9. Multibeam scanning electron microscope : Experimental results

    NARCIS (Netherlands)

    Mohammadi-Gheidari, A.; Hagen, C.W.; Kruit, P.

    2010-01-01

    The authors present the first results obtained with their multibeam scanning electron microscope. For the first time, they were able to image 196 (array of 14×14) focused beams of a multielectron beam source on a specimen using single beam scanning electron microscope (SEM) optics. The system

  10. Historical evolution toward achieving ultrahigh vacuum in JEOL electron microscopes

    CERN Document Server

    Yoshimura, Nagamitsu

    2014-01-01

    This book describes the developmental history of the vacuum system of the transmission electron microscope (TEM) at the Japan Electron Optics Laboratory (JEOL) from its inception to its use in today’s high-technology microscopes. The author and his colleagues were engaged in developing vacuum technology for electron microscopes (JEM series) at JEOL for many years. This volume presents a summary and explanation of their work and the technology that makes possible a clean ultrahigh vacuum. The typical users of the TEM are top-level researchers working at the frontiers of new materials or with new biological specimens. They often use the TEM under extremely severe conditions, with problems sometimes occurring in the vacuum system of the microscopes. JEOL engineers then must work as quickly as possible to improve the vacuum evacuation system so as to prevent the recurrence of such problems. Among the wealth of explanatory material in this book are examples of users’ reports of problems in the vacuum system of...

  11. Scanning Electron Microscopy in modern dentistry research

    OpenAIRE

    Paradella, Thaís Cachuté; Unesp-FOSJC; Bottino, Marco Antonio; Unesp-FOSJC

    2012-01-01

    The purpose of this article was to review the usage of Scanning Electron Microscopy (SEM) in dentistry research nowadays, through a careful and updated literature review. By using the key-words Scanning Electron Microscopy and one of the following areas of research in dentistry (Endodontics, Periodontics and Implant), in international database (PubMed), in the year of 2012 (from January to September), a total of 112 articles were found. This data was tabled and the articles were classified ac...

  12. Measurement of the electron charge by a vacuum diode

    Science.gov (United States)

    Lacsný, Boris; Štubňa, Igor

    2016-03-01

    The measurement of the electron charge is a suitable experimental assignment for high-school and undergraduate courses of physics. We used two vacuum electron-tubes: (a) a double rectifying modern diode with an indirectly heated cathode and (b) a specially prepared double diode with a directly heated cathode and thermocouple. There was a small retarding potential between the cathode and anode, which gave an opportunity to assume Maxwell’s distribution of the velocities of the emitted electrons for the measurement of the electron charge. The electrical scheme for this measurement is simple and common electronic devices can be used. We obtained the value for the electron charge (1.491 ± 0.036) × 10-19 C if measured on the common commercial double diode vacuum-tube with the use of an optical pyrometer and (1.611 ± 0074) × 10-19 C if measured on the specially prepared double diode vacuum-tube using a thermocouple to determine the cathode temperature. The obtained values of the electron charge differs 0.11 × 10-19 C and 0.01 × 10-19 C from the currently accepted value e = 1.6021766208(98) × 10-19 C.

  13. The theory and practice of high resolution scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Joy, D.C. (Tennessee Univ., Knoxville, TN (USA) Oak Ridge National Lab., TN (USA))

    1990-01-01

    Recent advances in instrumentation have produced the first commercial examples of what can justifiably be called High Resolution Scanning Electron Microscopes. The key components of such instruments are a cold field emission gun, a small-gap immersion probe-forming lens, and a clean dry-pumped vacuum. The performance of these microscopes is characterized by several major features including a spatial resolution, in secondary electron mode on solid specimens, which can exceed 1nm on a routine basis; an incident probe current density of the order of 10{sup 6} amps/cm{sup 2}; and the ability to maintain these levels of performance over an accelerating voltage range of from 1 to 30keV. This combination of high resolution, high probe current, low contamination and flexible electron-optical conditions provides many new opportunitites for the application of the SEM to materials science, physics, and the life sciences. 27 refs., 14 figs.

  14. Ultra-high vacuum scanning thermal microscopy for nanometer resolution quantitative thermometry.

    Science.gov (United States)

    Kim, Kyeongtae; Jeong, Wonho; Lee, Woochul; Reddy, Pramod

    2012-05-22

    Understanding energy dissipation at the nanoscale requires the ability to probe temperature fields with nanometer resolution. Here, we describe an ultra-high vacuum (UHV)-based scanning thermal microscope (SThM) technique that is capable of quantitatively mapping temperature fields with ∼15 mK temperature resolution and ∼10 nm spatial resolution. In this technique, a custom fabricated atomic force microscope (AFM) cantilever, with a nanoscale Au-Cr thermocouple integrated into the tip of the probe, is used to measure temperature fields of surfaces. Operation in an UHV environment eliminates parasitic heat transport between the tip and the sample enabling quantitative measurement of temperature fields on metal and dielectric surfaces with nanoscale resolution. We demonstrate the capabilities of this technique by directly imaging thermal fields in the vicinity of a 200 nm wide, self-heated, Pt line. Our measurements are in excellent agreement with computational results-unambiguously demonstrating the quantitative capabilities of the technique. UHV-SThM techniques will play an important role in the study of energy dissipation in nanometer-sized electronic and photonic devices and the study of phonon and electron transport at the nanoscale.

  15. Wettability study using transmitted electrons in environmental scanning electron microscope

    Science.gov (United States)

    Barkay, Z.

    2010-05-01

    A method for quantitative wettability study at nanoscale is presented. It is based on measuring transmitted electrons through nanodroplets using wet scanning transmission electron microscope (wet-STEM) detector in environmental scanning electron microscope. The quantitative information of the nanodroplet shape and contact angle is obtained by fitting Monte Carlo simulation results for transmitted electrons through spherical cap geometry with the experimental wet-STEM results. The characterization is demonstrated for particles and for initial stages of water droplet condensation over a nonhomogeneous holey carbon grid. The method is suggested for application in thin polymer and biological films.

  16. Development of Scanning Ultrafast Electron Microscope Capability.

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Kimberlee Chiyoko [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Talin, Albert Alec [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Chandler, David W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Michael, Joseph R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Modern semiconductor devices rely on the transport of minority charge carriers. Direct examination of minority carrier lifetimes in real devices with nanometer-scale features requires a measurement method with simultaneously high spatial and temporal resolutions. Achieving nanometer spatial resolutions at sub-nanosecond temporal resolution is possible with pump-probe methods that utilize electrons as probes. Recently, a stroboscopic scanning electron microscope was developed at Caltech, and used to study carrier transport across a Si p-n junction [ 1 , 2 , 3 ] . In this report, we detail our development of a prototype scanning ultrafast electron microscope system at Sandia National Laboratories based on the original Caltech design. This effort represents Sandia's first exploration into ultrafast electron microscopy.

  17. Scanning electron microscopy study of Trichomonas gallinae.

    Science.gov (United States)

    Tasca, Tiana; De Carli, Geraldo A

    2003-12-01

    A scanning electron microscopy (SEM) study of Trichomonas gallinae (Rivolta, 1878), provided more information about the morphology of this flagellated protozoan. SEM showed the morphological features of the trophozoites; the emergence of the anterior flagella, the structure of the undulating membrane, the position and shape of the pelta, axostyle and posterior flagellum. Of special interest were the pseudocyst forms.

  18. Application of Concentrated Electron Beams in Extra-Vacuum Technologies

    Science.gov (United States)

    Gorshkov, Oleg; Iliin, A. A.; Lovtsov, A. S.; Rizakhanov, R. N.

    2001-10-01

    At present time the rise in development of the technology with using the concentrated electron beams in gas with atmospheric pressure is observed. Besides the technologies, which are usually carried out in vacuum and connected with surface modification by the concentrated energy flows (welding, cutting, metal surface hardening), at present time the plasma chemical processes become of greater interest. These are processes with using the beam of fast electrons to initiate the plasma chemical reactions. One of such technologies is gas cleaning of the toxic impurities (nitrogen oxides and sulfur oxides and etc.) The electron-beam gas cleaning of the toxic impurities (for example Ebara-process) is based on radiation-enhanced combining of toxic impurities. The disadvantage of this method are high level of consumed power during the gas cleaning and difficulties in devices development for the output of electron beam with megawatt unit power with foil outlet, as the facilities of this very power are necessary for the real industrial application. These problems can be solved by using the devices with concentrated electron beam output into the atmosphere. In this case the beam is transported into the dense gas through the system of lock chambers, independently pumped. But unlike the beam, output through the foil window, the concentrated electron beam is characterized by the noticeable spatial irregularity in distribution of temperature, plasma concentration and area of radiation. This paper is devoted to consideration of using the concentrated electron beams in extra-vacuum technologies.

  19. Advantages of environmental scanning electron microscopy in studies of microorganisms.

    Science.gov (United States)

    Collins, S P; Pope, R K; Scheetz, R W; Ray, R I; Wagner, P A; Little, B J

    1993-08-01

    Microorganisms, including bacteria, fungi, protozoa, and microalgae, are composed predominantly of water which prohibits direct observation in a traditional scanning electron microscope (SEM). Preparation for SEM requires that microorganisms be fixed, frozen or dehydrated, and coated with a conductive film before observation in a high vacuum environment. Sample preparation may mechanically disturb delicate samples, compromise morphological information, and introduce other artifacts. The environmental scanning electron microscope (ESEM) provides a technology for imaging hydrated or dehydrated biological samples with minimal manipulation and without the need for conductive coatings. Sporulating cultures of three fungi, Aspergillus sp., Cunninghamella sp., and Mucor sp., were imaged in the ESEM to assess usefulness of the instrument in the direct observation of delicate, uncoated, biological specimens. Asexual sporophores showed no evidence of conidial displacement or disruption of sporangia. Uncoated algal cells of Euglena gracilis and Spirogyra sp. were examined using the backscatter electron detector (BSE) and the environmental secondary electron detector (ESD) of the ESEM. BSE images had more clearly defined intracellular structures, whereas ESD gave a clearer view of the surface E. gracilis cells fixed with potassium permanganate, Spirogyra sp. stained with Lugol's solution, and Saprolegnia sp. fixed with osmium tetroxide were compared using BSE and ESD to demonstrate that cellular details could be enhanced by the introduction of heavy metals. The effect of cellular water on signal quality was evaluated by comparing hydrated to critical point dried specimens.

  20. ELECTRON AVALANCHE MODEL OF DIELECTRIC-VACUUM SURFACE BREAKDOWN

    Energy Technology Data Exchange (ETDEWEB)

    Lauer, E J

    2007-02-21

    The model assumes that an 'initiating event' results in positive ions on the surface near the anode and reverses the direction of the normal component of electric field so that electrons in vacuum are attracted to the dielectric locally. A sequence of surface electron avalanches progresses in steps from the anode to the cathode. For 200 kV across 1 cm, the spacing of avalanches is predicted to be about 13 microns. The time for avalanches to step from the anode to the cathode is predicted to be about a ns.

  1. Femtosecond electron-bunch dynamics in laser wakefields and vacuum

    Directory of Open Access Journals (Sweden)

    A. G. Khachatryan

    2007-12-01

    Full Text Available Recent advances in laser wakefield acceleration demonstrated the generation of extremely short (with a duration of a few femtoseconds relativistic electron bunches with relatively low (of the order of couple of percent energy spread. In this article we study the dynamics of such bunches in drift space (vacuum and in channel-guided laser wakefields. Analytical solutions were found for the transverse coordinate of an electron and for the bunch envelope in the wakefield in the case of arbitrary change in the energy. Our results show strong bunch dynamics already on a millimeter scale propagation distance both in plasma and in vacuum. When the bunch propagates in vacuum, its transverse sizes grow considerably; the same is observed for the normalized bunch emittance that worsens the focusability of the bunch. A scheme of two-stage laser wakefield accelerator with small drift space between the stages is proposed. It is found that fast longitudinal betatron phase mixing occurs in a femtosecond bunch when it propagates along the wakefield axis. When bunch propagates off axis, strong bunch decoherence and fast emittance degradation due to the finite bunch length was observed.

  2. Aberration corrected Lorentz scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    McVitie, S., E-mail: stephen.mcvitie@glasgow.ac.uk; McGrouther, D.; McFadzean, S.; MacLaren, D.A.; O’Shea, K.J.; Benitez, M.J.

    2015-05-15

    We present results from an aberration corrected scanning transmission electron microscope which has been customised for high resolution quantitative Lorentz microscopy with the sample located in a magnetic field free or low field environment. We discuss the innovations in microscope instrumentation and additional hardware that underpin the imaging improvements in resolution and detection with a focus on developments in differential phase contrast microscopy. Examples from materials possessing nanometre scale variations in magnetisation illustrate the potential for aberration corrected Lorentz imaging as a tool to further our understanding of magnetism on this lengthscale. - Highlights: • Demonstration of nanometre scale resolution in magnetic field free environment using aberration correction in the scanning transmission electron microscope (STEM). • Implementation of differential phase contrast mode of Lorentz microscopy in aberration corrected STEM with improved sensitivity. • Quantitative imaging of magnetic induction of nanostructures in amorphous and cross-section samples.

  3. Scanning electron microscopic observations on bone.

    Science.gov (United States)

    Anderson, C; Danylchuk, K D

    1977-01-01

    The maceration technique employed in the preparation of specimens of bone for museum purposes has also been found to be of use in the preparation of fresh specimens for study with the scanning electron microscope. The technique requires less technical supervision, permits a greater underprocessing to overprocessing margin, and allows comparability of recent biopsy material with previously macerated bone specimens with no less detail than that found by other authors using other techniques on biopsy material.

  4. Scanning electron microscopy of superficial white onychomycosis*

    Science.gov (United States)

    de Almeida Jr., Hiram Larangeira; Boabaid, Roberta Oliveira; Timm, Vitor; Silva, Ricardo Marques e; de Castro, Luis Antonio Suita

    2015-01-01

    Superficial white onychomycosis is characterized by opaque, friable, whitish superficial spots on the nail plate. We examined an affected halux nail of a 20-year-old male patient with scanning electron microscopy. The mycological examination isolated Trichophyton mentagrophytes. Abundant hyphae with the formation of arthrospores were found on the nail's surface, forming small fungal colonies. These findings showed the great capacity for dissemination of this form of onychomycosis. PMID:26560225

  5. Scanning electron microscopy of molluscum contagiosum*

    OpenAIRE

    Almeida Jr,Hiram Larangeira de; Abuchaim,Martha Oliveira; Schneide, Maiko Abel; Marques, Leandra; Castro, Luis Antônio Suíta de

    2013-01-01

    Molluscum contagiosum is a disease caused by a poxvirus. It is more prevalent in children up to 5 years of age. There is a second peak of incidence in young adults. In order to examine its ultrastructure, three lesions were curetted without disruption, cut transversely with a scalpel, and routinely processed for scanning electron microscopy (SEM). The oval structure of molluscum contagiosum could be easily identified. In its core, there was a central umbilication and just below this depressio...

  6. Scanning electron microscopy of cold gases

    Science.gov (United States)

    Santra, Bodhaditya; Ott, Herwig

    2015-06-01

    Ultracold quantum gases offer unique possibilities to study interacting many-body quantum systems. Probing and manipulating such systems with ever increasing degree of control requires novel experimental techniques. Scanning electron microscopy is a high resolution technique which can be used for in situ imaging, single site addressing in optical lattices and precision density engineering. Here, we review recent advances and achievements obtained with this technique and discuss future perspectives.

  7. Cathodoluminescence in the scanning transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Kociak, M., E-mail: mathieu.kociak@u-psud.fr [Laboratoire de Physique des Solides, Université Paris-SudParis-Sud, CNRS-UMR 8502, Orsay 91405 (France); Zagonel, L.F. [“Gleb Wataghin” Institute of Physics University of Campinas - UNICAMP, 13083-859 Campinas, São Paulo (Brazil)

    2017-05-15

    Cathodoluminescence (CL) is a powerful tool for the investigation of optical properties of materials. In recent years, its combination with scanning transmission electron microscopy (STEM) has demonstrated great success in unveiling new physics in the field of plasmonics and quantum emitters. Most of these results were not imaginable even twenty years ago, due to conceptual and technical limitations. The purpose of this review is to present the recent advances that broke these limitations, and the new possibilities offered by the modern STEM-CL technique. We first introduce the different STEM-CL operating modes and the technical specificities in STEM-CL instrumentation. Two main classes of optical excitations, namely the coherent one (typically plasmons) and the incoherent one (typically light emission from quantum emitters) are investigated with STEM-CL. For these two main classes, we describe both the physics of light production under electron beam irradiation and the physical basis for interpreting STEM-CL experiments. We then compare STEM-CL with its better known sister techniques: scanning electron microscope CL, photoluminescence, and electron energy-loss spectroscopy. We finish by comprehensively reviewing recent STEM-CL applications. - Highlights: • Reviews the field of STEM-CL. • Introduces the technical requirements and challenges for STEM-CL. • Introduces the different types of excitations probed by STEM-CL. • Gives comprehensive overview of the last fifteenth years in the field.

  8. Dopant profiling with the scanning electron microscope

    CERN Document Server

    Elliott, S L

    2001-01-01

    This dissertation is a detailed study of dopant profiling with the scanning electron microscope (SEM) using secondary electrons. The technique has been applied to a wide variety of doped silicon, gallium arsenide and gallium nitride semiconductor test structures as well as a metal-oxide field effect transistor and several light emitting diodes. A concise set of guide-lines are provided for users of this technique, including the optimum SEM operating conditions that should be used for maximum contrast, an image manipulation procedure, and the resolution and sensitivity limits that can be expected. Dopant contrast observed with the SEM has been studied over the past few years by a number of researchers, and a theory for the contrast has evolved. This theory considers the patch fields outside the specimen to be the dominant factor determining the secondary electron intensity. In this dissertation the contrast mechanism has been further investigated by examining the contrast at different temperatures and after su...

  9. Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers

    Science.gov (United States)

    2015-01-01

    colin.joye@nrl.navy.mil Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers Figure 2. Results from the 220 GHz TWT . (a) Small signal...Completed tube under hot test. 220 GHz TWT Demonstration The 220 GHz TWT device was based on spare parts from a commercially available CPI VKY2444T G...existing parts, our TWT bested this COTS EIK performance by a factor of 12x in power and 50x in bandwidth for the same size, weight and prime power

  10. Vacuum ultraviolet electronic properties of liquids. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Painter, L.R.

    1980-06-01

    A program to study the electronic structure of liquids over the energy range from 2 to 25 eV was carried out from November, 1968 to October 1980. These studies basically consisted of measuring the reflectance, transmittance, photoionization, and photoemission of liquids in the vacuum ultraviolet spectral region as a function of angle of incidence and photon energy. Such measurements are analyzed to yield the optical and dielectric functions of the liquid as functions of photon energy. A summary of the progress in the program is presented. (GHT)

  11. Ultra-High Vacuum Compatible Optical Chopper System for Synchrotron X-ray Scanning Tunneling Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hao; Cummings, Marvin L.; Shirato, Nozomi; Stripe, Benjamin D.; Rosenmann, Daniel; Preissner, Curt A.; Freeland, John W.; Kersell, Heath R.; Hla, Saw Wai; Rose, Volker

    2015-01-01

    High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

  12. Ultra-high vacuum compatible optical chopper system for synchrotron x-ray scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hao, E-mail: hc000211@ohio.edu [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Nanoscale and Quantum Phenomena Institute, Physics & Astronomy Department, Ohio University, Athens, Ohio 45701 (United States); Cummings, Marvin; Shirato, Nozomi; Stripe, Benjamin; Preissner, Curt; Freeland, John W. [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Rosenmann, Daniel [Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Kersell, Heath; Hla, Saw-Wai [Nanoscale and Quantum Phenomena Institute, Physics & Astronomy Department, Ohio University, Athens, Ohio 45701 (United States); Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Rose, Volker, E-mail: vrose@anl.gov [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States)

    2016-01-28

    High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

  13. Analysis of improvement in performance and design parameters for enhancing resolution in an atmospheric scanning electron microscope.

    Science.gov (United States)

    Yoon, Yeo Hun; Kim, Seung Jae; Kim, Dong Hwan

    2015-12-01

    The scanning electron microscope is used in various fields to go beyond diffraction limits of the optical microscope. However, the electron pathway should be conducted in a vacuum so as not to scatter electrons. The pretreatment of the sample is needed for use in the vacuum. To directly observe large and fully hydrophilic samples without pretreatment, the atmospheric scanning electron microscope (ASEM) is needed. We developed an electron filter unit and an electron detector unit for implementation of the ASEM. The key of the electron filter unit is that electrons are transmitted while air molecules remain untransmitted through the unit. The electron detector unit collected the backscattered electrons. We conducted experiments using the selected materials with Havar foil, carbon film and SiN film. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Phase-contrast scanning transmission electron microscopy.

    Science.gov (United States)

    Minoda, Hiroki; Tamai, Takayuki; Iijima, Hirofumi; Hosokawa, Fumio; Kondo, Yukihito

    2015-06-01

    This report introduces the first results obtained using phase-contrast scanning transmission electron microscopy (P-STEM). A carbon-film phase plate (PP) with a small center hole is placed in the condenser aperture plane so that a phase shift is introduced in the incident electron waves except those passing through the center hole. A cosine-type phase-contrast transfer function emerges when the phase-shifted scattered waves interfere with the non-phase-shifted unscattered waves, which passed through the center hole before incidence onto the specimen. The phase contrast resulting in P-STEM is optically identical to that in phase-contrast transmission electron microscopy that is used to provide high contrast for weak phase objects. Therefore, the use of PPs can enhance the phase contrast of the STEM images of specimens in principle. The phase shift resulting from the PP, whose thickness corresponds to a phase shift of π, has been confirmed using interference fringes displayed in the Ronchigram of a silicon single crystal specimen. The interference fringes were found to abruptly shift at the edge of the PP hole by π. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Towards Automated Nanomanipulation under Scanning Electron Microscopy

    Science.gov (United States)

    Ye, Xutao

    Robotic Nanomaterial Manipulation inside scanning electron microscopes (SEM) is useful for prototyping functional devices and characterizing one-dimensional nanomaterial's properties. Conventionally, manipulation of nanowires has been performed via teleoperation, which is time-consuming and highly skill-dependent. Manual manipulation also has the limitation of low success rates and poor reproducibility. This research focuses on a robotic system capable of automated pick-place of single nanowires. Through SEM visual detection and vision-based motion control, the system transferred individual silicon nanowires from their growth substrate to a microelectromechanical systems (MEMS) device that characterized the nanowires' electromechanical properties. The performances of the nanorobotic pick-up and placement procedures were quantified by experiments. The system demonstrated automated nanowire pick-up and placement with high reliability. A software system for a load-lock-compatible nanomanipulation system is also designed and developed in this research.

  16. Scanning electron microscopy of molluscum contagiosum*

    Science.gov (United States)

    de Almeida Jr, Hiram Larangeira; Abuchaim, Martha Oliveira; Schneider, Maiko Abel; Marques, Leandra; de Castro, Luis Antônio Suíta

    2013-01-01

    Molluscum contagiosum is a disease caused by a poxvirus. It is more prevalent in children up to 5 years of age. There is a second peak of incidence in young adults. In order to examine its ultrastructure, three lesions were curetted without disruption, cut transversely with a scalpel, and routinely processed for scanning electron microscopy (SEM). The oval structure of molluscum contagiosum could be easily identified. In its core, there was a central umbilication and just below this depression, there was a keratinized tunnel. Under higher magnification, a proliferation similar to the epidermis was seen. Moreover, there were areas of cells disposed like a mosaic. Under higher magnification, rounded structures measuring 0.4 micron could be observed at the end of the keratinized tunnel and on the surface of the lesion. PMID:23539009

  17. From the physics of secondary electron emission to image contrasts in scanning electron microscopy.

    Science.gov (United States)

    Cazaux, Jacques

    2012-01-01

    Image formation in scanning electron microscopy (SEM) is a combination of physical processes, electron emissions from the sample, and of a technical process related to the detection of a fraction of these electrons. For the present survey of image contrasts in SEM, simplified considerations in the physics of the secondary electron emission yield, δ, are combined with the effects of a partial collection of the emitted secondary electrons. Although some consideration is initially given to the architecture of modern SEM, the main attention is devoted to the material contrasts with the respective roles of the sub-surface and surface compositions of the sample, as well as with the roles of the field effects in the vacuum gap. The recent trends of energy filtering in normal SEM and the reduction of the incident energy to a few electron volts in very low-energy electron microscopy are also considered. For an understanding by the SEM community, the mathematical expressions are explained with simple physical arguments.

  18. Simplifying Electron Beam Channeling in Scanning Transmission Electron Microscopy (STEM).

    Science.gov (United States)

    Wu, Ryan J; Mittal, Anudha; Odlyzko, Michael L; Mkhoyan, K Andre

    2017-08-01

    Sub-angstrom scanning transmission electron microscopy (STEM) allows quantitative column-by-column analysis of crystalline specimens via annular dark-field images. The intensity of electrons scattered from a particular location in an atomic column depends on the intensity of the electron probe at that location. Electron beam channeling causes oscillations in the STEM probe intensity during specimen propagation, which leads to differences in the beam intensity incident at different depths. Understanding the parameters that control this complex behavior is critical for interpreting experimental STEM results. In this work, theoretical analysis of the STEM probe intensity reveals that intensity oscillations during specimen propagation are regulated by changes in the beam's angular distribution. Three distinct regimes of channeling behavior are observed: the high-atomic-number (Z) regime, in which atomic scattering leads to significant angular redistribution of the beam; the low-Z regime, in which the probe's initial angular distribution controls intensity oscillations; and the intermediate-Z regime, in which the behavior is mixed. These contrasting regimes are shown to exist for a wide range of probe parameters. These results provide a new understanding of the occurrence and consequences of channeling phenomena and conditions under which their influence is strengthened or weakened by characteristics of the electron probe and sample.

  19. Revealing the 1 nm/s Extensibility of Nanoscale Amorphous Carbon in a Scanning Electron Microscope

    DEFF Research Database (Denmark)

    Zhang, Wei

    2013-01-01

    In an ultra-high vacuum scanning electron microscope, the edged branches of amorphous carbon film (∼10 nm thickness) can be continuously extended with an eye-identifying speed (on the order of ∼1 nm/s) under electron beam. Such unusual mobility of amorphous carbon may be associated with deformati...... positive implications to explore some amorphous carbon as electron field emission device. SCANNING 35: 261-264, 2013. © 2012 Wiley Periodicals, Inc.......In an ultra-high vacuum scanning electron microscope, the edged branches of amorphous carbon film (∼10 nm thickness) can be continuously extended with an eye-identifying speed (on the order of ∼1 nm/s) under electron beam. Such unusual mobility of amorphous carbon may be associated with deformation...... promoted by the electric field, which resulted from an inner secondary electron potential difference from the main trunk of carbon film to the tip end of branches under electron beam. This result demonstrates importance of applying electrical effects to modify properties of carbon materials. It may have...

  20. Dental Wear: A Scanning Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Luca Levrini

    2014-01-01

    Full Text Available Dental wear can be differentiated into different types on the basis of morphological and etiological factors. The present research was carried out on twelve extracted human teeth with dental wear (three teeth showing each type of wear: erosion, attrition, abrasion, and abfraction studied by scanning electron microscopy (SEM. The study aimed, through analysis of the macro- and micromorphological features of the lesions (considering the enamel, dentin, enamel prisms, dentinal tubules, and pulp, to clarify the different clinical and diagnostic presentations of dental wear and their possible significance. Our results, which confirm current knowledge, provide a complete overview of the distinctive morphology of each lesion type. It is important to identify the type of dental wear lesion in order to recognize the contributing etiological factors and, consequently, identify other more complex, nondental disorders (such as gastroesophageal reflux, eating disorders. It is clear that each type of lesion has a specific morphology and mechanism, and further clinical studies are needed to clarify the etiological processes, particularly those underlying the onset of abfraction.

  1. Large area scanning probe microscope in ultra-high vacuum demonstrated for electrostatic force measurements on high-voltage devices

    Directory of Open Access Journals (Sweden)

    Urs Gysin

    2015-12-01

    Full Text Available Background: The resolution in electrostatic force microscopy (EFM, a descendant of atomic force microscopy (AFM, has reached nanometre dimensions, necessary to investigate integrated circuits in modern electronic devices. However, the characterization of conducting or semiconducting power devices with EFM methods requires an accurate and reliable technique from the nanometre up to the micrometre scale. For high force sensitivity it is indispensable to operate the microscope under high to ultra-high vacuum (UHV conditions to suppress viscous damping of the sensor. Furthermore, UHV environment allows for the analysis of clean surfaces under controlled environmental conditions. Because of these requirements we built a large area scanning probe microscope operating under UHV conditions at room temperature allowing to perform various electrical measurements, such as Kelvin probe force microscopy, scanning capacitance force microscopy, scanning spreading resistance microscopy, and also electrostatic force microscopy at higher harmonics. The instrument incorporates beside a standard beam deflection detection system a closed loop scanner with a scan range of 100 μm in lateral and 25 μm in vertical direction as well as an additional fibre optics. This enables the illumination of the tip–sample interface for optically excited measurements such as local surface photo voltage detection.Results: We present Kelvin probe force microscopy (KPFM measurements before and after sputtering of a copper alloy with chromium grains used as electrical contact surface in ultra-high power switches. In addition, we discuss KPFM measurements on cross sections of cleaved silicon carbide structures: a calibration layer sample and a power rectifier. To demonstrate the benefit of surface photo voltage measurements, we analysed the contact potential difference of a silicon carbide p/n-junction under illumination.

  2. System and method for compressive scanning electron microscopy

    Science.gov (United States)

    Reed, Bryan W

    2015-01-13

    A scanning transmission electron microscopy (STEM) system is disclosed. The system may make use of an electron beam scanning system configured to generate a plurality of electron beam scans over substantially an entire sample, with each scan varying in electron-illumination intensity over a course of the scan. A signal acquisition system may be used for obtaining at least one of an image, a diffraction pattern, or a spectrum from the scans, the image, diffraction pattern, or spectrum representing only information from at least one of a select subplurality or linear combination of all pixel locations comprising the image. A dataset may be produced from the information. A subsystem may be used for mathematically analyzing the dataset to predict actual information that would have been produced by each pixel location of the image.

  3. Time-Resolved Scanning Electron Microscopy

    National Research Council Canada - National Science Library

    Weber, Peter M

    2006-01-01

    .... The pulsed electron beam is obtained by rapidly switching the electron emission of a field emission tip using the AC electric field arising from exposure to the intense electromagnetic radiation...

  4. Image Resolution in Scanning Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Pennycook, S. J.; Lupini, A.R.

    2008-06-26

    Digital images captured with electron microscopes are corrupted by two fundamental effects: shot noise resulting from electron counting statistics and blur resulting from the nonzero width of the focused electron beam. The generic problem of computationally undoing these effects is called image reconstruction and for decades has proved to be one of the most challenging and important problems in imaging science. This proposal concerned the application of the Pixon method, the highest-performance image-reconstruction algorithm yet devised, to the enhancement of images obtained from the highest-resolution electron microscopes in the world, now in operation at Oak Ridge National Laboratory.

  5. Development of precision numerical controlled high vacuum electron beam welding machine

    CERN Document Server

    Li Shao Lin

    2002-01-01

    The structure, main technical parameters and characteristics of the precision numerical controlled high vacuum electron beam welding machine are introduced. The design principle, some features and solutions to some key technique problems of this new type machine are described

  6. In-vacuum active electronics for microfabricated ion traps.

    Science.gov (United States)

    Guise, Nicholas D; Fallek, Spencer D; Hayden, Harley; Pai, C-S; Volin, Curtis; Brown, K R; Merrill, J True; Harter, Alexa W; Amini, Jason M; Lust, Lisa M; Muldoon, Kelly; Carlson, Doug; Budach, Jerry

    2014-06-01

    The advent of microfabricated ion traps for the quantum information community has allowed research groups to build traps that incorporate an unprecedented number of trapping zones. However, as device complexity has grown, the number of digital-to-analog converter (DAC) channels needed to control these devices has grown as well, with some of the largest trap assemblies now requiring nearly one hundred DAC channels. Providing electrical connections for these channels into a vacuum chamber can be bulky and difficult to scale beyond the current numbers of trap electrodes. This paper reports on the development and testing of an in-vacuum DAC system that uses only 9 vacuum feedthrough connections to control a 78-electrode microfabricated ion trap. The system is characterized by trapping single and multiple (40)Ca(+) ions. The measured axial mode stability, ion heating rates, and transport fidelities for a trapped ion are comparable to systems with external (air-side) commercial DACs.

  7. Systems and Methods for Fabricating Carbon Nanotube-Based Vacuum Electronic Devices

    Science.gov (United States)

    Manohara, Harish (Inventor); Toda, Risaku (Inventor); Del Castillo, Linda Y. (Inventor); Murthy, Rakesh (Inventor)

    2015-01-01

    Systems and methods in accordance with embodiments of the invention proficiently produce carbon nanotube-based vacuum electronic devices. In one embodiment a method of fabricating a carbon nanotube-based vacuum electronic device includes: growing carbon nanotubes onto a substrate to form a cathode; assembling a stack that includes the cathode, an anode, and a first layer that includes an alignment slot; disposing a microsphere partially into the alignment slot during the assembling of the stack such that the microsphere protrudes from the alignment slot and can thereby separate the first layer from an adjacent layer; and encasing the stack in a vacuum sealed container.

  8. Technology scan for electronic toll collection.

    Science.gov (United States)

    2008-06-01

    The purpose of this project was to identify and assess available technologies and methodologies for electronic toll collection (ETC) and to develop recommendations for the best way(s) to implement toll collection in the Louisville metropolitan area. ...

  9. Cobalt Chemical Vapor Deposition Process on Molybdenite Basal Plane Observed by Ultrahigh-Vacuum Scanning Tunneling Microscopy

    Science.gov (United States)

    Komiyama, Masaharu; Kiyohara, Kohei; Yoda, Eisuke; Kubota, Takeshi; Okamoto, Yasuaki

    2005-07-01

    The processes of high-temperature (473 K) resulfidation and cobalt carbonyl adsorption by chemical vapor deposition (CVD) on a cleaved basal plane of a natural molybdenite (MoS2) single crystal were examined by ultrahigh-vacuum scanning tunneling microscopy (UHV-STM) on the nanometer scale. The resulfided cleaved molybdenite basal plane showed a displacement of upper terraces, and a sinusoidal structure at step edges, both of which may be caused by the electronic effect at the surface. Cobalt carbonyl appeared to be adsorbed at both the S- and Mo-terminated edges, resulting in an agglomeration at the step edges on lower terraces with a width of a few tens of nanometers. When this surface with adsorbed carbonyl was sulfided at 513 K for 1 h, most of the adsorbed carbonyl clusters appeared to be desorbed while a small part were dispersed on the terraces in small clusters of 10-20 nm in size. The obtained results are discussed in terms of the preparation of Co-Mo hydrodesulfurization (HDS) catalysts.

  10. Evolution of MEMS scanning mirrors for laser projection in compact consumer electronics

    Science.gov (United States)

    Tauscher, Jason; Davis, Wyatt O.; Brown, Dean; Ellis, Matt; Ma, Yunfei; Sherwood, Michael E.; Bowman, David; Helsel, Mark P.; Lee, Sung; Coy, John Wyatt

    2010-02-01

    The applicability of MOEMS scanning mirrors towards the creation of "flying spot" scanned laser displays is well established. The extension of this concept towards compact embedded pico-projectors has required an evolution of scanners and packaging to accommodate the needs of the consumer electronics space. This paper describes the progression of the biaxial MOEMS scanning mirrors developed by Microvision over recent years. Various aspects of the individual designs are compared. Early devices used a combination of magnetic quasistatic actuation and resonant electrostatic operation in an evacuated atmosphere to create a projection engine for retinal scanned displays. Subsequent designs realized the elimination of both the high voltage electrostatic drive and the vacuum package, and a simplification of the actuation scheme through proprietary technical advances. Additional advances have doubled the scan angle capability and greatly miniaturized the MOEMS component while not incurring significant increase in power consumption, making it an excellent fit for the consumer pico-projector application. The simplicity of the scanned laser-based pico-projector optical design enables high resolution and a large effective image size in a thin projection engine, all of which become critical both to the viability of the technology and adoption by consumers. Microvision's first scanned laser pico-projector is built around a MOEMS scanning mirror capable of projecting 16:9 aspect ratio, WVGA display within a 6.6 mm high package. Further evolution on this path promises continued improvement in resolution, size, and power.

  11. Scanning electron microscopic evaluation of root canal surfaces ...

    African Journals Online (AJOL)

    2014-07-15

    50. How to cite this article: Hema BS, Chandu GS, Shiraguppi VL. Scanning electron microscopic evaluation of root canal surfaces prepared with three rotary endodontic systems: Lightspeed, ProTaper and EndoWave. Niger J.

  12. Simulation study of secondary electron images in scanning ion microscopy

    CERN Document Server

    Ohya, K

    2003-01-01

    The target atomic number, Z sub 2 , dependence of secondary electron yield is simulated by applying a Monte Carlo code for 17 species of metals bombarded by Ga ions and electrons in order to study the contrast difference between scanning ion microscopes (SIM) and scanning electron microscopes (SEM). In addition to the remarkable reversal of the Z sub 2 dependence between the Ga ion and electron bombardment, a fine structure, which is correlated to the density of the conduction band electrons in the metal, is calculated for both. The brightness changes of the secondary electron images in SIM and SEM are simulated using Au and Al surfaces adjacent to each other. The results indicate that the image contrast in SIM is much more sensitive to the material species and is clearer than that for SEM. The origin of the difference between SIM and SEM comes from the difference in the lateral distribution of secondary electrons excited within the escape depth.

  13. UAVSAR Active Electronically-Scanned Array

    Science.gov (United States)

    Sadowy, Gregory; Brown, Kyle; Chamberlain, Neil; Figueroa, Harry; Fisher, Charlie; Grando, Maurio; Hamilton, Gary; Vorperian, Vatche; Zawadzki, Mark

    2010-01-01

    The Uninhabited Airborne Vehicle Synthetic Aperture Radar (UAVSAR) L-band (1.2-1.3 GHz) repeat pass, interferometric synthetic aperture radar (InSAR) used for Earth science applications. Using complex radar images collected during separate passes on time scales of hours to years, changes in surface topography can be measured. The repeat-pass InSAR technique requires that the radar look angle be approximately the same on successive passes. Due to variations in aircraft attitude between passes, antenna beam steering is required to replicate the radar look angle. This paper describes an active, electronically steered array (AESA) that provides beam steering capability in the antenna azimuth plane. The array contains 24 transmit/receive modules generating 2800 W of radiated power and is capable of pulse-to-pulse beam steering and polarization agility. Designed for high reliability as well as serviceability, all array electronics are contained in single 178cm x 62cm x 12 cm air-cooled panel suitable for operation up 60,000 ft altitude.

  14. Electronic properties of (Zn,CoO systems probed by scanning tunnelling spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Moldovan

    2008-05-01

    Full Text Available The aim of this paper is to gain insight into theelectronic properties of (Zn,CoO system - a widebandgap Diluted Magnetic Semiconductors (DMSshowing room temperature (RT ferromagnetism undern-type doping conditions. On the experimental side, ultrahigh-vacuum scanning tunnelling microscopy andspectroscopy (STM and STS at variable temperature (Tare used to probe the local electronic structure of thesystem. It is presented the map of the local density ofstates (LDOS of polar ZnO surfaces. Then, it is possibleto decorate (incorporate Co atoms onto (into thesemiconductor.

  15. Characterization of Polycaprolactone Films Biodeterioration by Scanning Electron Microscopy

    Czech Academy of Sciences Publication Activity Database

    Hrubanová, Kamila; Voberková, S.; Hermanová, S.; Krzyžánek, Vladislav

    2014-01-01

    Roč. 20, S3 (2014), s. 1950-1951 ISSN 1431-9276 R&D Projects: GA MŠk EE.2.3.20.0103; GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : polycaprolactone films * biodeterioration * scanning electron microscopy Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.877, year: 2014

  16. Micro-four-point probes in a UHV scanning electron microscope for in-situ surface-conductivity measurements

    DEFF Research Database (Denmark)

    Shiraki, I.; Nagao, T.; Hasegawa, S.

    2000-01-01

    For in-situ measurements of surface conductivity in ultrahigh vacuum (UHV), we have installed micro-four-point probes (probe spacings down to 4 mum) in a UHV scanning electron microscope (SEM) combined with scanning reflection-high-energy electron diffraction (RHEED). With the aid of piezoactuators...... for precise positioning of the probes, local conductivity of selected surface domains of well-defined superstructures could be measured during SEM and RHEED observations. It was found that the surface sensitivity of the conductivity measurements was enhanced by reducing the probe spacing, enabling...

  17. Research on area source electron gun in vacuum system

    Science.gov (United States)

    Qiu, Yafeng; Chang, Benkang; Shi, Feng; Qian, Yunsheng; Fu, Rongguo

    High-energy area source electron gun is a key component in image intensifier screen testing instrument. On the basis of the analysis of relationship between thermal emission characteristics, the shape of filament and the density of thermal electron emission, high-energy area source electron gun is designed. The distribution of electric field and electronic tracks are theoretically analyzed and calculated to make it has features of dispersing, uniform, converging and submerging. By testing a standard screen, correct the structure of high-energy area source electron gun to meet the requirements of test indexes and obtain reasonable high-energy area source electron gun. Its successful development provides effective technical support to the luminous screen test for uniformity, brightness, luminescence efficiency and afterglow and to the examination of other components (such as MCP parameters)of Low-light Image Intensifier.

  18. Charge compensation by in-situ heating for insulating ceramics in scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Li [Institute of Microstructure and Property of Advanced Materials, Beijing University of Technology, Beijing 100124 (China); Ji, Yuan, E-mail: jiyuan@bjut.edu.cn [Institute of Microstructure and Property of Advanced Materials, Beijing University of Technology, Beijing 100124 (China); Wei, Bin; Zhang, Yinqi; Fu, Jingyong; Xu, Xuedong; Han, Xiaodong [Institute of Microstructure and Property of Advanced Materials, Beijing University of Technology, Beijing 100124 (China)

    2009-10-15

    With a steady temperature increase under high vacuum (HV) in an environmental scanning electronic microscope, we observed charge-free characterization and fine secondary electron (SE) images in focus for insulating ceramics (alumina (Al{sub 2}O{sub 3}), aluminum nitride (AlN), pure magnesium silicate (Mg{sub 2}SiO{sub 4})). The sample current I{sub sc} increased from -8.18x10{sup -13} to 2.76x10{sup -7} A for Al{sub 2}O{sub 3} and -9.28x10{sup -12} to 2.77x10{sup -6} A for AlN with the temperature increased from 298 to 633 K. The surface conductance {sigma} increased from 5.6x10{sup -13} to 5.0x10{sup -11}/{Omega} for Al{sub 2}O{sub 3} and 1.1x10{sup -12} to 1.0x10{sup -7}/{Omega} for AlN with the temperature increased from 363 to 593 K. The SE image contrast obtained via heating approach in high vacuum with an Everhart-Thornley SE-detector was better than that via conventional approach of electron-ion neutralization in low vacuum (LV) with a gaseous SE-detector. The differences of compensation temperatures for charge effects indicate dielectric and thermal properties, and band structures of insulators. The charge compensation mechanisms of heating approach mainly relate to accelerated release of trapped electrons on insulating surface and to increase of electron emission yield by heating.

  19. Optimizing chirped laser pulse parameters for electron acceleration in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Akhyani, Mina; Jahangiri, Fazel; Niknam, Ali Reza; Massudi, Reza, E-mail: r-massudi@sbu.ac.ir [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran 1983969411 (Iran, Islamic Republic of)

    2015-11-14

    Electron dynamics in the field of a chirped linearly polarized laser pulse is investigated. Variations of electron energy gain versus chirp parameter, time duration, and initial phase of laser pulse are studied. Based on maximizing laser pulse asymmetry, a numerical optimization procedure is presented, which leads to the elimination of rapid fluctuations of gain versus the chirp parameter. Instead, a smooth variation is observed that considerably reduces the accuracy required for experimentally adjusting the chirp parameter.

  20. Transmission electron imaging in the Delft multibeam scanning electron microscope 1

    NARCIS (Netherlands)

    Ren, Y.; Kruit, P.

    2016-01-01

    Our group is developing a multibeam scanning electron microscope (SEM) with 196 beams in order to increase the throughput of SEM. Three imaging systems using, respectively, transmission electron detection, secondary electron detection, and backscatter electron detection are designed in order to

  1. Two types of proton-electron atoms in a vacuum and an extremely strong magnetic field

    CERN Document Server

    Fedaruk, R

    2010-01-01

    The Rutherford planetary model of a proton-electron atom is modified. Besides the Coulomb interaction of the point electron with the proton, its strong Coulomb interaction with the physical vacuum as well as the magnetic interaction between moving charges are taken into account. The vacuum interaction leads to the motion of the electron with the velocity of light \\textit{c} in the circle with the radius being equal to the so-called classical electron radius $r_e$. Therefore, the velocity of the electron consists of two components: the velocity $\\vec{\\upsilon }$ of the mechanical motion and the velocity $\\vec{c}$ of the photon-like motion. We postulate that $\\vec{\\upsilon }\\bot \\vec{c}$, and $\\upsilon > r_e $) and short ($ r > 10^8 T$) that are typical for neutron stars are discussed.

  2. Composition quantification of electron-transparent samples by backscattered electron imaging in scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Müller, E., E-mail: erich.mueller@kit.edu; Gerthsen, D.

    2017-02-15

    The contrast of backscattered electron (BSE) images in scanning electron microscopy (SEM) depends on material parameters which can be exploited for composition quantification if some information on the material system is available. As an example, the In-concentration in thin In{sub x}Ga{sub 1−x}As layers embedded in a GaAs matrix is analyzed in this work. The spatial resolution of the technique is improved by using thin electron-transparent specimens instead of bulk samples. Although the BSEs are detected in a comparably small angular range by an annular semiconductor detector, the image intensity can be evaluated to determine the composition and local thickness of the specimen. The measured intensities are calibrated within one single image to eliminate the influence of the detection and amplification system. Quantification is performed by comparison of experimental and calculated data. Instead of using time-consuming Monte-Carlo simulations, an analytical model is applied for BSE-intensity calculations which considers single electron scattering and electron diffusion. - Highlights: • Sample thickness and composition are quantified by backscattered electron imaging. • A thin sample is used to achieve spatial resolution of few nanometers. • Calculations are carried out with a time-saving electron diffusion model. • Small differences in atomic number and density detected at low electron energies.

  3. Scanning tunneling spectroscopy on electron-boson interactions in superconductors

    CERN Document Server

    Schackert, Michael Peter

    2015-01-01

    This work describes the experimental study of electron-boson interactions in superconductors by means of inelastic electron tunneling spectroscopy performed with a scanning tunneling microscope (STM) at temperatures below 1 K. This new approach allows the direct measurement of the Eliashberg function of conventional superconductors as demonstrated on lead (Pb) and niobium (Nb). Preparative experiments on unconventional iron-pnictides are presented in the end.

  4. Applications of orientation mapping by scanning and transmission electron microscopy

    DEFF Research Database (Denmark)

    Juul Jensen, D.

    1997-01-01

    The potentials of orientation mapping techniques (in the following referred to as OIM) for studies of thermomechanical processes are analysed. Both transmission electron microscopy (TEM) and scanning electron microscopy (SEM) based OIM techniques are considered. Among the thermomechanical processes...... information is achieved when the results of OIM and these various techniques are combined. Examples hereof are given to illustrate the potentials of OIM techniques. Finally, limitations of TEM and SEM based OIM for specific applications are discussed....

  5. Scanning electron microscopy-energy dispersive X-ray spectrometer ...

    African Journals Online (AJOL)

    The distribution of arsenic (As) and cadmium (Cd) in himematsutake was analyzed using scanning electron microscopy-energy dispersive X-ray spectrometer (SEM-EDX). The atomic percentage of the metals was confirmed by inductively coupled plasma-mass spectrometer (ICP-MS). Results show that the accumulation of ...

  6. [Scanning electron microscope study of chemically disinfected endodontic files].

    Science.gov (United States)

    Navarro, G; Mateos, M; Navarro, J L; Canalda, C

    1991-01-01

    Forty stainless steel endodontic files were observed at scanning electron microscopy after being subjected to ten disinfection cycles of 10 minutes each one, immersed in different chemical disinfectants. Corrosion was not observed on the surface of the files in circumstances that this study was made.

  7. New Scanning Electron Microscope Used for Cryogenic Tensile Testing

    CERN Multimedia

    Maximilien Brice

    2013-01-01

    At CERN engineering department's installation for cryogenic tensile testing, the new scanning electron microscope (SEM) allows for detailed optical observations to be carried out. Using the SEM, surface coatings and tensile properties of materials can investigated in order to better understand how they behave under different conditions.

  8. Scanning electron microscopy of Dermatobia hominis reveals cutaneous anchoring features.

    Science.gov (United States)

    Möhrenschlager, Matthias; Mempel, Martin; Weichenmeier, Ingrid; Engst, Reinhard; Ring, Johannnes; Behrendt, Heidrun

    2007-10-01

    We report the case of a 45-year-old Caucasian woman suffering from cutaneous myiasis. With the use of scanning electron microscopy, we placed special focus on the mechanisms by which Dermatobia hominis can fasten securely within the human skin.

  9. Scanning electron microscopic evaluation of root canal surfaces ...

    African Journals Online (AJOL)

    Scanning electron microscopic evaluation of root canal surfaces prepared with three rotary endodontic systems: Lightspeed, ProTaper and EndoWave. ... presence or absence of debris and smear layer and the photographs were taken at coronal, middle and apical 1/3 with a magnification of ~200 and ~1000 respectively.

  10. Assessment of root surfaces of apicected teeth: A scanning electron ...

    African Journals Online (AJOL)

    2014-05-15

    May 15, 2014 ... Objectives: The aim of this study was to determine the apical surface characteristics and presence of dental cracks in single‑rooted premolars, resected 3.0 mm from the root apex, using the Er: YAG laser, tungsten carbide bur, and diamond‑coated tip, by scanning electron microscopy (SEM). Experimental ...

  11. Assessment of root surfaces of apicected teeth: A scanning electron ...

    African Journals Online (AJOL)

    Objectives: The aim of this study was to determine the apical surface characteristics and presence of dental cracks in single‑rooted premolars, resected 3.0 mm from the root apex, using the Er: YAG laser, tungsten carbide bur, and diamond‑coated tip, by scanning electron microscopy (SEM). Experimental design: Thirty ...

  12. Femtosecond electron-bunch dynamics in laser wakefields and vacuum

    NARCIS (Netherlands)

    Khachatryan, A.G.; Irman, A.; van Goor, F.A.; Boller, Klaus J.

    2007-01-01

    Recent advances in laser wakefield acceleration demonstrated the generation of extremely short (with a duration of a few femtoseconds) relativistic electron bunches with relatively low (of the order of couple of percent) energy spread. In this article we study the dynamics of such bunches in drift

  13. Field Emission Vacuum (FEV) Electronic Devices for Operation Above 500 Degrees Celsius

    Science.gov (United States)

    Peltz, L.; Jones, W. M.; Frampton, R. V.; Keith, A. R.; Scherer, A.

    2017-11-01

    Boeing is teamed with Caltech to develop FEV (Field-Emission Vacuum) electronics. Our Boeing-Caltech team has recently begun work, under NASA ROSES C.24 HOTTech program, to demonstrate robust FEV operating at 500C, towards Venus surface missions.

  14. High-resolution low-dose scanning transmission electron microscopy.

    Science.gov (United States)

    Buban, James P; Ramasse, Quentin; Gipson, Bryant; Browning, Nigel D; Stahlberg, Henning

    2010-01-01

    During the past two decades instrumentation in scanning transmission electron microscopy (STEM) has pushed toward higher intensity electron probes to increase the signal-to-noise ratio of recorded images. While this is suitable for robust specimens, biological specimens require a much reduced electron dose for high-resolution imaging. We describe here protocols for low-dose STEM image recording with a conventional field-emission gun STEM, while maintaining the high-resolution capability of the instrument. Our findings show that a combination of reduced pixel dwell time and reduced gun current can achieve radiation doses comparable to low-dose TEM.

  15. Proposed Physics Experiments for Laser-Driven Electron Linear Acceleration in a Dielectric Loaded Vacuum, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Byer, Robert L. [Stanford Univ., CA (United States). Dept. of Applied Physics. Edward L. Ginzton Lab.

    2016-07-08

    This final report summarizes the last three years of research on the development of advanced linear electron accelerators that utilize dielectric wave-guide vacuum channels pumped by high energy laser fields to accelerate beams of electrons.

  16. Closed-Loop Autofocus Scheme for Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Cui Le

    2015-01-01

    Full Text Available In this paper, we present a full scale autofocus approach for scanning electron microscope (SEM. The optimal focus (in-focus position of the microscope is achieved by maximizing the image sharpness using a vision-based closed-loop control scheme. An iterative optimization algorithm has been designed using the sharpness score derived from image gradient information. The proposed method has been implemented and validated using a tungsten gun SEM at various experimental conditions like varying raster scan speed, magnification at real-time. We demonstrate that the proposed autofocus technique is accurate, robust and fast.

  17. Parallel electron-beam-induced deposition using a multi-beam scanning electron microscope

    NARCIS (Netherlands)

    Post, P.C.; Mohammadi-Gheidari, A.; Hagen, C.W.; Kruit, P.

    2011-01-01

    Lithography techniques based on electron-beam-induced processes are inherently slow compared to light lithography techniques. The authors demonstrate here that the throughput can be enhanced by a factor of 196 by using a scanning electron microscope equipped with a multibeam electron source. Using

  18. Miniaturized Environmental Scanning Electron Microscope for In Situ Planetary Studies

    Science.gov (United States)

    Gaskin, Jessica; Abbott, Terry; Medley, Stephanie; Gregory, Don; Thaisen, Kevin; Taylor , Lawrence; Ramsey, Brian; Jerman, Gregory; Sampson, Allen; Harvey, Ralph

    2010-01-01

    The exploration of remote planetary surfaces calls for the advancement of low power, highly-miniaturized instrumentation. Instruments of this nature that are capable of multiple types of analyses will prove to be particularly useful as we prepare for human return to the moon, and as we continue to explore increasingly remote locations in our Solar System. To this end, our group has been developing a miniaturized Environmental-Scanning Electron Microscope (mESEM) capable of remote investigations of mineralogical samples through in-situ topographical and chemical analysis on a fine scale. The functioning of an SEM is well known: an electron beam is focused to nanometer-scale onto a given sample where resulting emissions such as backscattered and secondary electrons, X-rays, and visible light are registered. Raster scanning the primary electron beam across the sample then gives a fine-scale image of the surface topography (texture), crystalline structure and orientation, with accompanying elemental composition. The flexibility in the types of measurements the mESEM is capable of, makes it ideally suited for a variety of applications. The mESEM is appropriate for use on multiple planetary surfaces, and for a variety of mission goals (from science to non-destructive analysis to ISRU). We will identify potential applications and range of potential uses related to planetary exploration. Over the past few of years we have initiated fabrication and testing of a proof-of-concept assembly, consisting of a cold-field-emission electron gun and custom high-voltage power supply, electrostatic electron-beam focusing column, and scanning-imaging electronics plus backscatter detector. Current project status will be discussed. This effort is funded through the NASA Research Opportunities in Space and Earth Sciences - Planetary Instrument Definition and Development Program.

  19. Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

    Science.gov (United States)

    Loyd, Jody; Gregory, Don; Gaskin, Jessica

    2016-01-01

    This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM

  20. Metallic Na formation in NaCl crystals with irradiation of electron or vacuum ultraviolet photon

    Energy Technology Data Exchange (ETDEWEB)

    Owaki, Shigehiro [Osaka Prefecture Univ., Sakai, Osaka (Japan). Coll. of Integrated Arts and Sciences; Koyama, Shigeko; Takahashi, Masao; Kamada, Masao; Suzuki, Ryouichi

    1997-03-01

    Metallic Na was formed in NaCl single crystals with irradiation of a variety of radiation sources and analyzed the physical states with several methods. In the case of irradiation of 21 MeV electron pulses to the crystal blocks, the optical absorption and lifetime measurement of positron annihilation indicated appearance of Na clusters inside. Radiation effects of electron beam of 30 keV to the crystals in vacuum showed the appearance of not only metallic Na but atomic one during irradiation with Auger electron spectroscopy. Intense photon fluxes in vacuum ultraviolet region of synchrotron radiation were used as another source and an analyzing method of ultraviolet photoelectron spectroscopy. The results showed the metallic Na layered so thick that bulk plasmon can exist. (author)

  1. Miniature Variable Pressure Scanning Electron Microscope for In-Situ Imaging and Chemical Analysis

    Science.gov (United States)

    Gaskin, Jessica A.; Jerman, Gregory; Gregory, Don; Sampson, Allen R.

    2012-01-01

    NASA Marshall Space Flight Center (MSFC) is leading an effort to develop a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for in-situ imaging and chemical analysis of uncoated samples. This instrument development will be geared towards operation on Mars and builds on a previous MSFC design of a mini-SEM for the moon (funded through the NASA Planetary Instrument Definition and Development Program). Because Mars has a dramatically different environment than the moon, modifications to the MSFC lunar mini-SEM are necessary. Mainly, the higher atmospheric pressure calls for the use of an electron gun that can operate at High Vacuum, rather than Ultra-High Vacuum. The presence of a CO2-rich atmosphere also allows for the incorporation of a variable pressure system that enables the in-situ analysis of nonconductive geological specimens. Preliminary testing of Mars meteorites in a commercial Environmental SEM(Tradmark) (FEI) confirms the usefulness of lowcurrent/low-accelerating voltage imaging and highlights the advantages of using the Mars atmosphere for environmental imaging. The unique capabilities of the MVP-SEM make it an ideal tool for pursuing key scientific goals of NASA's Flagship Mission Max-C; to perform in-situ science and collect and cache samples in preparation for sample return from Mars.

  2. Contribution of Metal Layer Thickness for Quantitative Backscattered Electron Imaging of Field Emission Scanning Electron Microscopy

    National Research Council Canada - National Science Library

    Kim, Hyonchol; Takei, Hiroyuki; Negishi, Tsutomu; Kudo, Masato; Terazono, Hideyuki; Yasuda, Kenji

    2012-01-01

    ...) imaging in field emission scanning electron microscopy (FE-SEM) were studied to evaluate the potential of using these particles as simultaneously distinguishable labels of target molecules in FE-SEM studies...

  3. Time-resolved scanning electron microscopy with polarization analysis

    Energy Technology Data Exchange (ETDEWEB)

    Frömter, Robert, E-mail: rfroemte@physik.uni-hamburg.de; Oepen, Hans Peter [Institut für Nanostruktur-und Festkörperphysik, Universität Hamburg, Jungiusstraße 11, 20355 Hamburg (Germany); The Hamburg Centre for Ultrafast Imaging, Luruper Chaussee 149, 22761 Hamburg (Germany); Kloodt, Fabian; Rößler, Stefan; Frauen, Axel; Staeck, Philipp; Cavicchia, Demetrio R. [Institut für Nanostruktur-und Festkörperphysik, Universität Hamburg, Jungiusstraße 11, 20355 Hamburg (Germany); Bocklage, Lars [Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg (Germany); The Hamburg Centre for Ultrafast Imaging, Luruper Chaussee 149, 22761 Hamburg (Germany); Röbisch, Volker; Quandt, Eckhard [Institute for Materials Science, Christian-Albrechts-Universität zu Kiel, 24143 Kiel (Germany)

    2016-04-04

    We demonstrate the feasibility of investigating periodically driven magnetization dynamics in a scanning electron microscope with polarization analysis based on spin-polarized low-energy electron diffraction. With the present setup, analyzing the time structure of the scattering events, we obtain a temporal resolution of 700 ps, which is demonstrated by means of imaging the field-driven 100 MHz gyration of the vortex in a soft-magnetic FeCoSiB square. Owing to the efficient intrinsic timing scheme, high-quality movies, giving two components of the magnetization simultaneously, can be recorded on the time scale of hours.

  4. Angularly-selective transmission imaging in a scanning electron microscope.

    Science.gov (United States)

    Holm, Jason; Keller, Robert R

    2016-08-01

    This work presents recent advances in transmission scanning electron microscopy (t-SEM) imaging control capabilities. A modular aperture system and a cantilever-style sample holder that enable comprehensive angular selectivity of forward-scattered electrons are described. When combined with a commercially available solid-state transmission detector having only basic bright-field and dark-field imaging capabilities, the advances described here enable numerous transmission imaging modes. Several examples are provided that demonstrate how contrast arising from diffraction to mass-thickness can be obtained. Unanticipated image contrast at some imaging conditions is also observed and addressed. Published by Elsevier B.V.

  5. Surface morphology of Trichinella spiralis by scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, C.W. (State Univ. of New York, Stony Brook); Ledbetter, M.C.

    1980-02-01

    The surface morphology of larval and adult Trichinella spiralis was studied by scanning electron microscopy (SEM) of fixed, dried, and metal-coated specimens. The results are compared with those found earlier by various investigators using light and transmission electron microscopy. Some morphological features reported here are revealed uniquely by SEM. These include the pores of the cephalic sense organs, the character of secondary cuticular folds, variations of the hypodermal gland cell openings or pores, and the presence of particles on the copulatory bell.

  6. Advanced Scanning Electron Microscopy and X Ray Microanalysis

    Science.gov (United States)

    Krinsley, David

    This text is the third in a group that evolved from a short course taught annually at Lehigh University, Bethlehem, Pa., since 1972. Chapters on magnetic contrast a nd electron channeling, dropped from the second volume for reasons of space, are included here along with new topics such as image processing. The first seven chapters should be oT value to those geologists interested in scanning electron microscopy (SEM) and microanalysis. Chapters 8 and 9, concerned with specimen preparation for biological SEM a nd cryomicroscopy, make up about one third of the text.

  7. Scanning transmission electron microscopy: Albert Crewe's vision and beyond.

    Science.gov (United States)

    Krivanek, Ondrej L; Chisholm, Matthew F; Murfitt, Matthew F; Dellby, Niklas

    2012-12-01

    Some four decades were needed to catch up with the vision that Albert Crewe and his group had for the scanning transmission electron microscope (STEM) in the nineteen sixties and seventies: attaining 0.5Å resolution, and identifying single atoms spectroscopically. With these goals now attained, STEM developments are turning toward new directions, such as rapid atomic resolution imaging and exploring atomic bonding and electronic properties of samples at atomic resolution. The accomplishments and the future challenges are reviewed and illustrated with practical examples. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Scanning electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1985-01-01

    The aim of this book is to outline the physics of image formation, electron­ specimen interactions, imaging modes, the interpretation of micrographs and the use of quantitative modes "in scanning electron microscopy (SEM). lt forms a counterpart to Transmission Electron Microscopy (Vol. 36 of this Springer Series in Optical Sciences) . The book evolved from lectures delivered at the University of Münster and from a German text entitled Raster-Elektronenmikroskopie (Springer-Verlag), published in collaboration with my colleague Gerhard Pfefferkorn. In the introductory chapter, the principles of the SEM and of electron­ specimen interactions are described, the most important imaging modes and their associated contrast are summarized, and general aspects of eiemental analysis by x-ray and Auger electron emission are discussed. The electron gun and electron optics are discussed in Chap. 2 in order to show how an electron probe of small diameter can be formed, how the elec­ tron beam can be blanked at high fre...

  9. Black hairy tongue. A scanning electron microscopic study.

    Science.gov (United States)

    Harada, Y; Gaafar, H

    1977-01-01

    A patient with tongue malignancy associated with a black hairy tongue is presented. Specimens from e area fo the black hairy tongue and from a normally appearing part were studied with the scanning electron microscope. The "hairs" consisted of elongated filiform papillae due to accumulated keratinized layers. In-between these layers, fungi and bacteria were found. The aetiology of the blck hairy tongue in this patient is discussed.

  10. Scanning Electron Microscopy of Cristispira Species in Chesapeake Bay Oysters

    OpenAIRE

    Tall, Ben D.; Nauman, Robert K.

    1981-01-01

    Scanning electron microscopy was employed to observe the physical interactions between Cristispira spp. and the crystalline style of the Chesapeake Bay oyster (Crassostrea virginica Gmelin 1791). Cristispira organisms were found associated with both the inner and outer layers of the posterior two-thirds of the style. The spirochetes possessed blunt-tipped ends, a cell diameter range of 0.6 to 0.8 μm, and distended spirochetal envelopes which followed the contour of the cells. Transmission ele...

  11. Scanning Electron Microscopy with Samples in an Electric Field

    Science.gov (United States)

    Frank, Ludĕk; Hovorka, Miloš; Mikmeková, Šárka; Mikmeková, Eliška; Müllerová, Ilona; Pokorná, Zuzana

    2012-01-01

    The high negative bias of a sample in a scanning electron microscope constitutes the “cathode lens” with a strong electric field just above the sample surface. This mode offers a convenient tool for controlling the landing energy of electrons down to units or even fractions of electronvolts with only slight readjustments of the column. Moreover, the field accelerates and collimates the signal electrons to earthed detectors above and below the sample, thereby assuring high collection efficiency and high amplification of the image signal. One important feature is the ability to acquire the complete emission of the backscattered electrons, including those emitted at high angles with respect to the surface normal. The cathode lens aberrations are proportional to the landing energy of electrons so the spot size becomes nearly constant throughout the full energy scale. At low energies and with their complete angular distribution acquired, the backscattered electron images offer enhanced information about crystalline and electronic structures thanks to contrast mechanisms that are otherwise unavailable. Examples from various areas of materials science are presented.

  12. Two-dimensional simulation research of secondary electron emission avalanche discharge on vacuum insulator surface

    Science.gov (United States)

    Cai, Libing; Wang, Jianguo; Zhu, Xiangqin; Wang, Yue; Zhang, Dianhui

    2015-01-01

    Based on the secondary electron emission avalanche (SEEA) model, the SEEA discharge on the vacuum insulator surface is simulated by using a 2D PIC-MCC code developed by ourselves. The evolutions of the number of discharge electrons, insulator surface charge, current, and 2D particle distribution are obtained. The effects of the strength of the applied electric field, secondary electron yield coefficient, rise time of the pulse, length of the insulator on the discharge are investigated. The results show that the number of the SEEA electrons presents a quadratic dependence upon the applied field strength. The SEEA current, which is on the order of Ampere, is directly proportional to the field strength and secondary electron yield coefficient. Finally, the electron-stimulated outgassing is included in the simulation code, and a three-phase discharge curve is presented by the simulation, which agrees with the experimental data.

  13. Simulation and Characterization of a Miniaturized Scanning Electron Microscope

    Science.gov (United States)

    Gaskin, Jessica A.; Jerman, Gregory A.; Medley, Stephanie; Gregory, Don; Abbott, Terry O.; Sampson, Allen R.

    2011-01-01

    A miniaturized Scanning Electron Microscope (mSEM) for in-situ lunar investigations is being developed at NASA Marshall Space Flight Center with colleagues from the University of Alabama in Huntsville (UAH), Advanced Research Systems (ARS), the University of Tennessee in Knoxville (UTK) and Case Western Reserve University (CWRU). This effort focuses on the characterization of individual components of the mSEM and simulation of the complete system. SEMs can provide information on the size, shape, morphology and chemical composition of lunar regolith. Understanding these basic properties will allow us to better estimate the challenges associated with In-Situ Resource Utilization and to improve our basic science knowledge of the lunar surface (either precluding the need for sample return or allowing differentiation of unique samples to be returned to Earth.) The main components of the mSEM prototype includes: a cold field emission electron gun (CFEG), focusing lens, deflection/scanning system and backscatter electron detector. Of these, the electron gun development is of particular importance as it dictates much of the design of the remaining components. A CFEG was chosen for use with the lunar mSEM as its emission does not depend on heating of the tungsten emitter (lower power), it offers a long operation lifetime, is orders of magnitude brighter than tungsten hairpin guns, has a small source size and exhibits low beam energy spread.

  14. Electron beam gun with kinematic coupling for high power RF vacuum devices

    Energy Technology Data Exchange (ETDEWEB)

    Borchard, Philipp

    2016-11-22

    An electron beam gun for a high power RF vacuum device has components joined by a fixed kinematic coupling to provide both precise alignment and high voltage electrical insulation of the components. The kinematic coupling has high strength ceramic elements directly bonded to one or more non-ductile rigid metal components using a high temperature active metal brazing alloy. The ceramic elements have a convex surface that mates with concave grooves in another one of the components. The kinematic coupling, for example, may join a cathode assembly and/or a beam shaping focus electrode to a gun stem, which is preferably composed of ceramic. The electron beam gun may be part of a high power RF vacuum device such as, for example, a gyrotron, klystron, or magnetron.

  15. A versatile atomic force microscope integrated with a scanning electron microscope

    Science.gov (United States)

    Kreith, J.; Strunz, T.; Fantner, E. J.; Fantner, G. E.; Cordill, M. J.

    2017-05-01

    A versatile atomic force microscope (AFM), which can be installed in a scanning electron microscope (SEM), is introduced. The flexible design of the instrument enables correlated analysis for different experimental configurations, such as AFM imaging directly after nanoindentation in vacuum. In order to demonstrate the capabilities of the specially designed AFM installed inside a SEM, slip steps emanating around nanoindents in single crystalline brass were examined. This example showcases how the combination of AFM and SEM imaging can be utilized for quantitative dislocation analysis through the measurement of the slip step heights without the hindrance of oxide formation. Finally, an in situ nanoindentation technique is introduced, illustrating the use of AFM imaging during indentation experiments to examine plastic deformation occurring under the indenter tip. The mechanical indentation data are correlated to the SEM and AFM images to estimate the number of dislocations emitted to the surface.

  16. Cryo scanning electron microscopy of Plasmodium falciparum-infected erythrocytes.

    Science.gov (United States)

    Hempel, Casper

    2017-07-01

    Plasmodium falciparum invades erythrocytes as an essential part of their life cycle. While living inside erythrocytes, the parasite remodels the cell's intracellular organization as well as its outer surface. Late trophozoite-stage parasites and schizonts introduce numerous small protrusions on the erythrocyte surface, called knobs. Current methods for studying these knobs include atomic force microscopy and electron microscopy. Standard electron microscopy methods rely on chemical fixation and dehydration modifying cell size. Here, a novel method is presented using rapid freezing and scanning electron microscopy under cryogenic conditions allowing for high resolution and magnification of erythrocytes. This novel technique can be used for precise estimates of knob density and for studies on cytoadhesion. © 2017 APMIS. Published by John Wiley & Sons Ltd.

  17. Probing Nanoscale Electronic and Magnetic Interaction with Scanning Tunneling Spectroscopy

    DEFF Research Database (Denmark)

    Bork, Jakob

    This thesis is concerned with fundamental research into electronic and magnetic interaction on the nanoscale. From small metallic and magnetic islands and layers to single atoms. The research revolves around magnetic interaction probed through the spectroscopic capabilities of the scanning....... This is related to research in correlated electron materials such as studies of phase transitions in heavy fermion compounds and magnetic interaction in spintronic research. The capping of cobalt islands on Cu(111) with silver is investigated with STM and photoemission spectroscopy. It is shown that at low...... coverage the silver preferably nucleates on top of the bilayer high cobalt islands compared to directly on the Cu(111) substrate. Furthermore, the silver forms a combination of a reconstruction and a Moire pattern which is investigated with low-energy electron diraction and spectroscopic STM mapping at 6...

  18. IASI OGSE Spot Scan: Design and realization of an infrared test equipment for use in vacuum

    NARCIS (Netherlands)

    Kappelhof, J.P.; Dekker, A.; Spierdijk, J.P.F.; Boslooper, E.C.; Bokhove, H.; Verhoeff, P.

    2003-01-01

    This paper presents the development of the IASI Infrared Spot Scan test equipment, with a focus on the mechanical design. The IASI instrument, developed by Alcatel, is a spaceborne meteorological instrument, for observation of the Earth atmosphere in the infrared wavelength region. An infrared

  19. Standard practice for scanning electron microscope beam Size characterization

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This practice provides a reproducible means by which one aspect of the performance of a scanning electron microscope (SEM) may be characterized. The resolution of an SEM depends on many factors, some of which are electron beam voltage and current, lens aberrations, contrast in the specimen, and operator-instrument-material interaction. However, the resolution for any set of conditions is limited by the size of the electron beam. This size can be quantified through the measurement of an effective apparent edge sharpness for a number of materials, two of which are suggested. This practice requires an SEM with the capability to perform line-scan traces, for example, Y-deflection waveform generation, for the suggested materials. The range of SEM magnification at which this practice is of utility is from 1000 to 50 000 × . Higher magnifications may be attempted, but difficulty in making precise measurements can be expected. 1.2 This standard does not purport to address all of the safety concerns, if any, ass...

  20. Gas Condensates onto a LHC Type Cryogenic Vacuum System Subjected to Electron Cloud

    CERN Multimedia

    Baglin, V

    2004-01-01

    In the Large Hadron Collider (LHC), the gas desorbed via photon stimulated molecular desorption or electron stimulated molecular desorption will be physisorbed onto the beam screen held between 5 and 20 K. Studies of the effects of the electron cloud onto a LHC type cryogenic vacuum chamber have been done with the cold bore experiment (COLDEX) installed in the CERN Super Proton Synchrotron (SPS). Experiments performed with gas condensates such as H2, H2O, CO and CO2 are described. Implications for the LHC design and operation are discussed.

  1. Serial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure

    Directory of Open Access Journals (Sweden)

    Denk Winfried

    2004-01-01

    Full Text Available Three-dimensional (3D structural information on many length scales is of central importance in biological research. Excellent methods exist to obtain structures of molecules at atomic, organelles at electron microscopic, and tissue at light-microscopic resolution. A gap exists, however, when 3D tissue structure needs to be reconstructed over hundreds of micrometers with a resolution sufficient to follow the thinnest cellular processes and to identify small organelles such as synaptic vesicles. Such 3D data are, however, essential to understand cellular networks that, particularly in the nervous system, need to be completely reconstructed throughout a substantial spatial volume. Here we demonstrate that datasets meeting these requirements can be obtained by automated block-face imaging combined with serial sectioning inside the chamber of a scanning electron microscope. Backscattering contrast is used to visualize the heavy-metal staining of tissue prepared using techniques that are routine for transmission electron microscopy. Low-vacuum (20-60 Pa H2O conditions prevent charging of the uncoated block face. The resolution is sufficient to trace even the thinnest axons and to identify synapses. Stacks of several hundred sections, 50-70 nm thick, have been obtained at a lateral position jitter of typically under 10 nm. This opens the possibility of automatically obtaining the electron-microscope-level 3D datasets needed to completely reconstruct the connectivity of neuronal circuits.

  2. Simulation of scanning transmission electron microscope images on desktop computers

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, C., E-mail: christian.dwyer@mcem.monash.edu.au [Monash Centre for Electron Microscopy, Department of Materials Engineering, Monash University, Victoria 3800 (Australia)

    2010-02-15

    Two independent strategies are presented for reducing the computation time of multislice simulations of scanning transmission electron microscope (STEM) images: (1) optimal probe sampling, and (2) the use of desktop graphics processing units. The first strategy is applicable to STEM images generated by elastic and/or inelastic scattering, and requires minimal effort for its implementation. Used together, these two strategies can reduce typical computation times from days to hours, allowing practical simulation of STEM images of general atomic structures on a desktop computer.

  3. Evaluation of the bleached human enamel by Scanning Electron Microscopy

    DEFF Research Database (Denmark)

    Miranda, Carolina Baptista; Pagani, Clovis; Benetti, Ana Raquel

    2005-01-01

    Since bleaching has become a popular procedure, the effect of peroxides on dental hard tissues is of great interest in research. Purpose: The aim of this in vitro study was to perform a qualitative analysis of the human enamel after the application of in-office bleaching agents, using Scanning...... Electron Microscopy (SEM). Materials and Methods: Twenty intact human third molars extracted for orthodontic reasons were randomly divided into four groups (n=5) treated as follows: G1- storage in artificial saliva (control group); G2- four 30-minute applications of 35% carbamide peroxide (total exposure...

  4. [Pulmonary hydatidosis. Comparison of cytology and scanning electron microscopy].

    Science.gov (United States)

    Lavaud, F; Nou, J M; Sadrin, R; de Montreynaud, J M; Adnet, J J

    1986-01-01

    The puncture of a hydatid cyst with a fine needle is not generally recommended as a procedure and may even be contra-indicated in the first instance. Sometimes, however, the cytologist will be surprised to discover some scolices in the aspirate when the radiology is misleading, or not suggestive, and the serology is negative. We report two cases where the diagnosis was made by the cytological examination of the aspirate. The cytological study of the liquids was compared with electron microscopy scanning, enabling the stages of development of the parasite in the tissue of the pulmonary parenchyma to be assessed.

  5. [Enamel bundles and lamellae under the scanning electron microscope].

    Science.gov (United States)

    Bures, H; Svejda, J

    1976-01-01

    Lamellae, tufts and cracks were found in the enamel near the dentionenamel junction. When investigated by the scanning electron microscop, lamellae and tufts were very similar to each other as to their structure. Lamellae appeared in two kinds: 1. Organic material originating in the dentionenamel membrane filled the whole space. 2. The space was empty, yet an organic membrane was covering the walls of adjacent prisms. Tufts and lamellae differed merely in their lenght. The walls of the cracks lacked organic material, the prisms being damaged or their course interrupted.

  6. Characteristics of different frequency ranges in scanning electron microscope images

    Energy Technology Data Exchange (ETDEWEB)

    Sim, K. S., E-mail: kssim@mmu.edu.my; Nia, M. E.; Tan, T. L.; Tso, C. P.; Ee, C. S. [Faculty of Engineering and Technology, Multimedia University, 75450 Melaka (Malaysia)

    2015-07-22

    We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.

  7. Adaptive noise Wiener filter for scanning electron microscope imaging system.

    Science.gov (United States)

    Sim, K S; Teh, V; Nia, M E

    2016-01-01

    Noise on scanning electron microscope (SEM) images is studied. Gaussian noise is the most common type of noise in SEM image. We developed a new noise reduction filter based on the Wiener filter. We compared the performance of this new filter namely adaptive noise Wiener (ANW) filter, with four common existing filters as well as average filter, median filter, Gaussian smoothing filter and the Wiener filter. Based on the experiments results the proposed new filter has better performance on different noise variance comparing to the other existing noise removal filters in the experiments. © Wiley Periodicals, Inc.

  8. [Scanning electron microscopy of heat-damaged bone tissue].

    Science.gov (United States)

    Harsanyl, L

    1977-02-01

    Parts of diaphyses of bones were exposed to high temperature of 200-1300 degrees C. Damage to the bone tissue caused by the heat was investigated. The scanning electron microscopic picture seems to be characteristic of the temperature applied. When the bones heated to the high temperature of 700 degrees C characteristic changes appear on the periostal surface, higher temperatura on the other hand causes damage to the compact bone tissue and can be observed on the fracture-surface. Author stresses the importance of this technique in the legal medicine and anthropology.

  9. Angularly-selective transmission imaging in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Holm, Jason, E-mail: jason.holm@nist.gov; Keller, Robert R.

    2016-08-15

    This work presents recent advances in transmission scanning electron microscopy (t-SEM) imaging control capabilities. A modular aperture system and a cantilever-style sample holder that enable comprehensive angular selectivity of forward-scattered electrons are described. When combined with a commercially available solid-state transmission detector having only basic bright-field and dark-field imaging capabilities, the advances described here enable numerous transmission imaging modes. Several examples are provided that demonstrate how contrast arising from diffraction to mass-thickness can be obtained. Unanticipated image contrast at some imaging conditions is also observed and addressed. - Highlights: • A modular aperture system for STEM-in-SEM imaging is described. • A flexible cantilever sample holder that can maximize camera length is described. • The aperture system and sample holder enable complete acceptance angle control. • Most STEM imaging modes can be implemented without multi-segment detectors.

  10. Electron beam confinement and image contrast enhancement in near field emission scanning electron microscopy.

    Science.gov (United States)

    Kirk, T L; De Pietro, L G; Pescia, D; Ramsperger, U

    2009-04-01

    In conventional scanning electron microscopy (SEM), the lateral resolution is limited by the electron beam diameter impinging on the specimen surface. Near field emission scanning electron microscopy (NFESEM) provides a simple means of overcoming this limit; however, the most suitable field emitter remains to be determined. NFESEM has been used in this work to investigate the W (110) surface with single-crystal tungsten tips of (310), (111), and (100)-orientations. The topographic images generated from both the electron intensity variations and the field emission current indicate higher resolution capabilities with decreasing tip work function than with polycrystalline tungsten tips. The confinement of the electron beam transcends the resolution limitations of the geometrical models, which are determined by the minimum beam width.

  11. Ion effects in the SLC electron damping ring under exceptionally poor vacuum conditions

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, F.; Krejcik, P.; Minty, M.; Pritzkau, D.; Raubenheimer, T.; Ross, M.; Woodley, M.

    1997-10-01

    In 1996, due to a catastrophic kicker chamber failure in the SLC electron damping ring, the ring vacuum system was contaminated for several months. During this time, the vertical emittance of the beam extracted from the ring was increased by a large factor (4--20). The emittance slowly decreased as the vacuum pressure gradually improved. At the same time, an intermittent vertical instability was observed. Both the emittance blow-up and the instability behavior depended strongly on beam current, ring pressure, number of bunches in the ring (1 or 2), duty cycle, store time and betatron tunes. In this report, the authors describe the observations, and compare them with predictions from classical ion-trapping and ion-instability theories.

  12. Photoemission and Injection Properties of a Vacuum Photodiode with Two Negative-Electron-Affinity Semiconductor Electrodes

    Science.gov (United States)

    Rodionov, A. A.; Golyashov, V. A.; Chistokhin, I. B.; Jaroshevich, A. S.; Derebezov, I. A.; Haisler, V. A.; Shamirzaev, T. S.; Marakhovka, I. I.; Kopotilov, A. V.; Kislykh, N. V.; Mironov, A. V.; Aksenov, V. V.; Tereshchenko, O. E.

    2017-09-01

    The photoemission and injection properties of two GaAs/(Al,Ga)As electrodes with effective negative electron affinity (NEA) are studied in the parallel-plate capacitorlike vacuum photodiode. Both electrodes are bonded to the glass of the input windows, allowing measuring the quantum yield in the transmission and reflection modes. The photodiode with NEA states of both electrodes is sensitive to the illumination in the 400-900 nm range and produces the photocurrent with no bias applied between electrodes. The energy distribution of emitted electrons is studied as a function of the transverse energy component to the surface in the temperature range of 20-300 K. The presence of the fine structure in the photoemission spectra is associated with the electron-phonon coupling in two-dimensional quantized states in the band-bending region. The two-electrode vacuum photoemission system demonstrates the negative differential conductivity. The cathodoluminescence signal is measured as a function of free-electron injection energy with the threshold appearance less than 0.05 V between electrodes.

  13. Bright-field scanning confocal electron microscopy using a double aberration-corrected transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Peng; Behan, Gavin; Kirkland, Angus I. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Nellist, Peter D., E-mail: peter.nellist@materials.ox.ac.uk [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Cosgriff, Eireann C.; D' Alfonso, Adrian J.; Morgan, Andrew J.; Allen, Leslie J. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Hashimoto, Ayako [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); Takeguchi, Masaki [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); High Voltage Electron Microscopy Station, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Mitsuishi, Kazutaka [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); Quantum Dot Research Center, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Shimojo, Masayuki [High Voltage Electron Microscopy Station, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Advanced Science Research Laboratory, Saitama Institute of Technology, 1690 Fusaiji, Fukaya 369-0293 (Japan)

    2011-06-15

    Scanning confocal electron microscopy (SCEM) offers a mechanism for three-dimensional imaging of materials, which makes use of the reduced depth of field in an aberration-corrected transmission electron microscope. The simplest configuration of SCEM is the bright-field mode. In this paper we present experimental data and simulations showing the form of bright-field SCEM images. We show that the depth dependence of the three-dimensional image can be explained in terms of two-dimensional images formed in the detector plane. For a crystalline sample, this so-called probe image is shown to be similar to a conventional diffraction pattern. Experimental results and simulations show how the diffracted probes in this image are elongated in thicker crystals and the use of this elongation to estimate sample thickness is explored. -- Research Highlights: {yields} The confocal probe image in a scanning confocal electron microscopy image reveals information about the thickness and height of the crystalline layer. {yields} The form of the contrast in a three-dimensional bright-field scanning confocal electron microscopy image can be explained in terms of the confocal probe image. {yields} Despite the complicated form of the contrast in bright-field scanning confocal electron microscopy, we see that depth information is transferred on a 10 nm scale.

  14. Advances in imaging and electron physics the scanning transmission electron microscope

    CERN Document Server

    Hawkes, Peter W

    2009-01-01

    Advances in Imaging and Electron Physics merges two long-running serials--Advances in Electronics and Electron Physics and Advances in Optical and Electron Microscopy. This series features extended articles on the physics of electron devices (especially semiconductor devices), particle optics at high and low energies, microlithography, image science and digital image processing, electromagnetic wave propagation, electron microscopy, and the computing methods used in all these domains.  This particular volume presents several timely articles on the scanning transmission electron microscope. Updated with contributions from leading international scholars and industry experts Discusses hot topic areas and presents current and future research trends Provides an invaluable reference and guide for physicists, engineers and mathematicians.

  15. Studying Dynamic Processes of Nano-sized Objects in Liquid using Scanning Transmission Electron Microscopy.

    Science.gov (United States)

    Hermannsdörfer, Justus; de Jonge, Niels

    2017-02-05

    Samples fully embedded in liquid can be studied at a nanoscale spatial resolution with Scanning Transmission Electron Microscopy (STEM) using a microfluidic chamber assembled in the specimen holder for Transmission Electron Microscopy (TEM) and STEM. The microfluidic system consists of two silicon microchips supporting thin Silicon Nitride (SiN) membrane windows. This article describes the basic steps of sample loading and data acquisition. Most important of all is to ensure that the liquid compartment is correctly assembled, thus providing a thin liquid layer and a vacuum seal. This protocol also includes a number of tests necessary to perform during sample loading in order to ensure correct assembly. Once the sample is loaded in the electron microscope, the liquid thickness needs to be measured. Incorrect assembly may result in a too-thick liquid, while a too-thin liquid may indicate the absence of liquid, such as when a bubble is formed. Finally, the protocol explains how images are taken and how dynamic processes can be studied. A sample containing AuNPs is imaged both in pure water and in saline.

  16. Destructive effects induced by the electron beam in scanning electron microscopy

    Science.gov (United States)

    Popescu, M. C.; Bita, B. I.; Banu, M. A.; Tomescu, R. M.

    2016-12-01

    The Scanning Electron Microscopy has been validated by its impressive imaging and reliable measuring as an essential characterization tool for a variety of applications and research fields. This paper is a comprehensive study dedicated to the undesirable influence of the accelerated electron beam associated with the dielectric materials, sensitive structures or inappropriate sample manipulation. Depending on the scanning conditions, the electron beam may deteriorate the investigated sample due to the extended focusing or excessive high voltage and probe current applied on vulnerable configurations. Our aim is to elaborate an instructive material for improved SEM visualization capabilities by overcoming the specific limitations of the technique. Particular examination and measuring methods are depicted along with essential preparation and manipulation procedures in order to protect the integrity of the sample. Various examples are mentioned and practical solutions are described in respect to the general use of the electron microscope.

  17. Three-Dimensional scanning transmission electron microscopy of biological specimens

    KAUST Repository

    De Jonge, Niels

    2010-01-18

    A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2-3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original dataset. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy. However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved dataset. © 2010 Microscopy Society of America.

  18. Electron beam detection of a Nanotube Scanning Force Microscope.

    Science.gov (United States)

    Siria, Alessandro; Niguès, Antoine

    2017-09-14

    Atomic Force Microscopy (AFM) allows to probe matter at atomic scale by measuring the perturbation of a nanomechanical oscillator induced by near-field interaction forces. The quest to improve sensitivity and resolution of AFM forced the introduction of a new class of resonators with dimensions at the nanometer scale. In this context, nanotubes are the ultimate mechanical oscillators because of their one dimensional nature, small mass and almost perfect crystallinity. Coupled to the possibility of functionalisation, these properties make them the perfect candidates as ultra sensitive, on-demand force sensors. However their dimensions make the measurement of the mechanical properties a challenging task in particular when working in cavity free geometry at ambient temperature. By using a focused electron beam, we show that the mechanical response of nanotubes can be quantitatively measured while approaching to a surface sample. By coupling electron beam detection of individual nanotubes with a custom AFM we image the surface topography of a sample by continuously measuring the mechanical properties of the nanoresonators. The combination of very small size and mass together with the high resolution of the electron beam detection method offers unprecedented opportunities for the development of a new class of nanotube-based scanning force microscopy.

  19. The Radiation Reaction of a Point Electron as a Planck Vacuum Response Phenomenon

    Directory of Open Access Journals (Sweden)

    Daywitt W. C.

    2010-04-01

    Full Text Available The polarizability of the Planck vacuum (PV transforms the bare Coulomb field e = r 2 of a point charge into the observed field e = r 2 , where e and e are the bare and observed electronic charges respectively [1]. In uniform motion this observed field is transformed into the well-known relativistic electric and magnetic fields [2, p.380] by the interac- tion taking place between the bare-charge field and the PV continuum. Given the in- volvement of the PV in both these transformations, it is reasonable to conclude that the negative-energy PV must also be connected to the radiation reaction or damping force of an accelerated point electron. This short paper examines that conclusion by compar- ing it to an early indication [3] that the point electron problem may involve more than just a massive point charge.

  20. A Brief Review on Metamaterial-Based Vacuum Electronics for Terahertz and Microwave Science and Technology

    Science.gov (United States)

    Matsui, Tatsunosuke

    2017-09-01

    Metamaterials, which enable us to realize novel physical effects that cannot be achieved using natural materials, have been extensively studied in recent years and significant progress has been made, especially in the field of optics. This game-changing concept has also initiated a rich variety of research activity in vacuum electronics. Here we review the recent development of metamaterial-based vacuum electronics for terahertz (THz) and microwave science and technology. The reversed Cherenkov radiation (RCR) in double-negative (DNG) metamaterials predicted by Veselago back in the 1960s has been experimentally verified in the microwave frequency range by utilizing specially designed DNG metamaterials. The interaction of an electron beam (e-beam) with DNG metamaterials may lead to the realization of novel applications such as microwave and THz radiation sources, accelerators, and even the visualization of invisibility cloaks. Smith-Purcell radiation (SPR) has recently received renewed interest owing to the development of metamaterials and the concept of spoof surface plasmon polaritons, as discussed in this review, and recent results on e-beam-induced directional and wide-band THz radiation with sharp multiple peaks from a graded grating, as well as directional and monochromatic special SPR and their possible application to THz orotron devices, are also reviewed.

  1. Use of high-thermal conductive aluminum nitride based ceramics in vacuum UHF electronic devices

    Directory of Open Access Journals (Sweden)

    Chasnyk V. I.

    2013-06-01

    Full Text Available Analysis of properties and characteristics of the alumina, beryllium oxide and aluminum nitride based ceramic materials used in UHF electronic devices has been made. It was shown that the complex of parameters including structural and functional characteristics of the high-thermal conductive aluminum nitride ceramics prevail over all types of alumina ceramics and is not lower than the same characteristics of the beryllium oxide ceramics especially at the temperatures higher than 450 °C. The examples of the prevailing use of the aluminum nitride ceramics inside vacuum UHF-region devices: TWT’s and klystrons.

  2. Identification of sandstone core damage using scanning electron microscopy

    Science.gov (United States)

    Ismail, Abdul Razak; Jaafar, Mohd Zaidi; Sulaiman, Wan Rosli Wan; Ismail, Issham; Shiunn, Ng Yinn

    2017-12-01

    Particles and fluids invasion into the pore spaces causes serious damage to the formation, resulting reduction in petroleum production. In order to prevent permeability damage for a well effectively, the damage mechanisms should be identified. In this study, water-based drilling fluid was compared to oil-based drilling fluids based on microscopic observation. The cores were damaged by several drilling fluid systems. Scanning electron microscope (SEM) was used to observe the damage mechanism caused by the drilling fluids. Results showed that the ester based drilling fluid system caused the most serious damage followed by synthetic oil based system and KCI-polymer system. Fine solids and filtrate migration and emulsion blockage are believed to be the major mechanisms controlling the changes in flow properties for the sandstone samples.

  3. Immunolabeling for scanning electron microscopy (SEM) and field emission SEM.

    Science.gov (United States)

    Goldberg, Martin W

    2008-01-01

    Scanning electron microscopy (SEM) is a high resolution surface imaging technique. Many biological process and structures occur at surfaces and if antibodies are available, their components can be located within the surface structure. This is usually done in a similar way to immuno-fluorescence, using an unconjugated primary antibody followed by a tagged secondary antibody against the primary. In this case the tag is usually a colloidal gold particle instead of a fluorophore. Therefore it is quite straightforward to adapt an immuno-fluorescence procedure for SEM, as long as certain precautions are followed, as discussed here. Progressing from immuno-fluorescence, which essentially only indicates the position of a protein within the volume of a cell, to immuno-SEM, puts the labeling into the context of cellular structures. The principles and practices of sample preparation, labeling and imaging are described here.

  4. Lagrange time delay estimation for scanning electron microscope image magnification.

    Science.gov (United States)

    Sim, K-S; Thong, L W; Ting, H Y; Tso, C P

    2010-02-01

    Interpolation techniques that are used for image magnification to obtain more useful details of the surface such as morphology and mechanical contrast usually rely on the signal information distributed around edges and areas of sharp changes and these signal information can also be used to predict missing details from the sample image. However, many of these interpolation methods tend to smooth or blur out image details around the edges. In the present study, a Lagrange time delay estimation interpolator method is proposed and this method only requires a small filter order and has no noticeable estimation bias. Comparing results with the original scanning electron microscope magnification and results of various other interpolation methods, the Lagrange time delay estimation interpolator is found to be more efficient, more robust and easier to execute.

  5. Cryo-Scanning Electron Microscopy of Captured Cirrus Ice Particles

    Science.gov (United States)

    Magee, N. B.; Boaggio, K.; Bandamede, M.; Bancroft, L.; Hurler, K.

    2016-12-01

    We present the latest collection of high-resolution cryo-scanning electron microscopy images and microanalysis of cirrus ice particles captured by high-altitude balloon (ICE-Ball, see abstracts by K. Boaggio and M. Bandamede). Ice particle images and sublimation-residues are derived from particles captured during approximately 15 balloon flights conducted in Pennsylvania and New Jersey over the past 12 months. Measurements include 3D digital elevation model reconstructions of ice particles, and associated statistical analyses of entire particles and particle sub-facets and surfaces. This 3D analysis reveals that morphologies of most ice particles captured deviate significantly from ideal habits, and display geometric complexity and surface roughness at multiple measureable scales, ranging from 100's nanometers to 100's of microns. The presentation suggests potential a path forward for representing scattering from a realistically complex array of ice particle shapes and surfaces.

  6. Trichomes of Cannabis sativa as viewed with scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Ledbetter, M.C.; Krikorian, A.D.

    1975-06-01

    Direct examination of fresh, unfixed and uncoated specimens from vegetative and floral parts of Cannabis sativa with the scanning electron microscope enables one to obtain a faithful representation of their surface morphology. The presence of two major types of trichomes has been confirmed: a glandular type comprising or terminating in a globoid structure, and a conically-shaped nonglandular type. Moreover, three or possibly four distinct glandular types can be distinguished: sessile globoid, small-stalked and large-stalked globoid, and a peltate type. The nonglandular trichomes can be distinguished by the nature of their surfaces: those with a warty surface, and those which are relatively smooth. The range of size and distribution, and the special features of all these types of trichomes are also provided.

  7. [Scanning electron microscopic study on newborn middle ear mucosa].

    Science.gov (United States)

    Li, Y

    1992-01-01

    Scanning electron microscopic studies were made on the mucosa of newborn middle ear. The results were: 1. The epithelial surface was found to contain four types of cell: the ciliated cell, the nonciliated cell without secretory granules (SG), the nonciliated cell with secretory granules (SG) and the flat cell. 2. The ciliated cell population appeared in the following order (from dense to sparse): eustachian tube, hypotympanum, antetympanum, epitympanum, promontory and post-tympanum. 3. The density of nonciliated cell without SG population was gradually increasing from anterior to posterior part of middle ear. 4. The population of nonciliated cell with SG was fewer and they were always found near the ciliated cells. 5. The flat cells were only seen on the flaccid part of tympanic membrane. This paper suggests that the ciliary system is basically mature and the development of mucus secreting members still is not perfect in newborn middle ear mucosa.

  8. Valence electron energy-loss spectroscopy in monochromated scanning transmission electron microscopy.

    Science.gov (United States)

    Erni, Rolf; Browning, Nigel D

    2005-10-01

    With the development of monochromators for (scanning) transmission electron microscopes, valence electron energy-loss spectroscopy (VEELS) is developing into a unique technique to study the band structure and optical properties of nanoscale materials. This article discusses practical aspects of spatially resolved VEELS performed in scanning transmission mode and the alignments necessary to achieve the current optimum performance of approximately 0.15 eV energy resolution with an electron probe size of approximately 1 nm. In particular, a collection of basic concepts concerning the acquisition process, the optimization of the energy resolution, the spatial resolution and the data processing are provided. A brief study of planar defects in a Y(1)Ba(2)Cu(3)O(7-)(delta) high-temperature superconductor illustrates these concepts and shows what kind of information can be accessed by VEELS.

  9. Experimental evaluation of environmental scanning electron microscopes at high chamber pressure.

    Science.gov (United States)

    Fitzek, H; Schroettner, H; Wagner, J; Hofer, F; Rattenberger, J

    2015-11-01

    In environmental scanning electron microscopy (ESEM) high pressure applications have become increasingly important. Wet or biological samples can be investigated without time-consuming sample preparation and potential artefacts from this preparation can be neglected. Unfortunately, the signal-to-noise ratio strongly decreases with increasing chamber pressure. To evaluate the high pressure performance of ESEM and to compare different electron microscopes, information about spatial resolution and detector type is not enough. On the one hand, the scattering of the primary electron beam increases, which vanishes the contrast in images; and on the other hand, the secondary electrons (SE) signal amplification decreases. The stagnation gas thickness (effective distance the beam has to travel through the imaging gas) as well as the SE detection system depend on the microscope and for a complete and serious evaluation of an ESEM or low vacuum SEM it is necessary to specify these two parameters. A method is presented to determine the fraction of scattered and unscattered electrons and to calculate the stagnation gas thickness (θ). To evaluate the high pressure performance of the SE detection system, a method is presented that allows for an analysis of a single image and the calculation of the signal-to-noise ratio of this image. All investigations are performed on an FEI ESEM Quanta 600 (field emission gun) and an FEI ESEM Quanta 200 (thermionic gun). These methods and measurements should represent opportunities for evaluating the high pressure performance of an ESEM. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  10. The Atmospheric Scanning Electron Microscope with open sample space observes dynamic phenomena in liquid or gas

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Mitsuo, E-mail: msuga@jeol.co.jp [Clair Project, JEOL Ltd., 3-1-2, Musashino, Akishima, Tokyo 196-8558 (Japan); Nishiyama, Hidetoshi; Konyuba, Yuji [Clair Project, JEOL Ltd., 3-1-2, Musashino, Akishima, Tokyo 196-8558 (Japan); Iwamatsu, Shinnosuke; Watanabe, Yoshiyuki [Yamagata Research Institute of Technology, 2-2-1, Matsuei, Yamagata, 990-2473 (Japan); Yoshiura, Chie; Ueda, Takumi [Graduate School of Pharmaceutical Sciences, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Sato, Chikara, E-mail: ti-sato@aist.go.jp [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-4, Umezono, Tsukuba 305-8568 (Japan)

    2011-12-15

    Although conventional electron microscopy (EM) requires samples to be in vacuum, most chemical and physical reactions occur in liquid or gas. The Atmospheric Scanning Electron Microscope (ASEM) can observe dynamic phenomena in liquid or gas under atmospheric pressure in real time. An electron-permeable window made of pressure-resistant 100 nm-thick silicon nitride (SiN) film, set into the bottom of the open ASEM sample dish, allows an electron beam to be projected from underneath the sample. A detector positioned below captures backscattered electrons. Using the ASEM, we observed the radiation-induced self-organization process of particles, as well as phenomena accompanying volume change, including evaporation-induced crystallization. Using the electrochemical ASEM dish, we observed tree-like electrochemical depositions on the cathode. In silver nitrate solution, we observed silver depositions near the cathode forming incidental internal voids. The heated ASEM dish allowed observation of patterns of contrast in melting and solidifying solder. Finally, to demonstrate its applicability for monitoring and control of industrial processes, silver paste and solder paste were examined at high throughput. High resolution, imaging speed, flexibility, adaptability, and ease of use facilitate the observation of previously difficult-to-image phenomena, and make the ASEM applicable to various fields. -- Highlights: Black-Right-Pointing-Pointer Atmospheric SEM (ASEM) observes dynamic phenomena in liquid or gas in open ASEM dish. Black-Right-Pointing-Pointer Random motion and radiation-induced self-organization were observed. Black-Right-Pointing-Pointer Tree-like electrochemical deposition of gold was observed on an electrode in situ. Black-Right-Pointing-Pointer Temperature-dependent phase transitions of solder were dynamically observed in air. Black-Right-Pointing-Pointer Silver and solder pastes were easily and rapidly observed in air for process control.

  11. Quantitative three-dimensional ice roughness from scanning electron microscopy

    Science.gov (United States)

    Butterfield, Nicholas; Rowe, Penny M.; Stewart, Emily; Roesel, David; Neshyba, Steven

    2017-03-01

    We present a method for inferring surface morphology of ice from scanning electron microscope images. We first develop a novel functional form for the backscattered electron intensity as a function of ice facet orientation; this form is parameterized using smooth ice facets of known orientation. Three-dimensional representations of rough surfaces are retrieved at approximately micrometer resolution using Gauss-Newton inversion within a Bayesian framework. Statistical analysis of the resulting data sets permits characterization of ice surface roughness with a much higher statistical confidence than previously possible. A survey of results in the range -39°C to -29°C shows that characteristics of the roughness (e.g., Weibull parameters) are sensitive not only to the degree of roughening but also to the symmetry of the roughening. These results suggest that roughening characteristics obtained by remote sensing and in situ measurements of atmospheric ice clouds can potentially provide more facet-specific information than has previously been appreciated.

  12. Amyloid Structure and Assembly: Insights from Scanning Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Goldsbury, C.; Wall, J.; Baxa, U.; Simon, M. N.; Steven, A. C.; Engel, A.; Aebi, U.; Muller, S. A.

    2011-01-01

    Amyloid fibrils are filamentous protein aggregates implicated in several common diseases such as Alzheimer's disease and type II diabetes. Similar structures are also the molecular principle of the infectious spongiform encephalopathies such as Creutzfeldt-Jakob disease in humans, scrapie in sheep, and of the so-called yeast prions, inherited non-chromosomal elements found in yeast and fungi. Scanning transmission electron microscopy (STEM) is often used to delineate the assembly mechanism and structural properties of amyloid aggregates. In this review we consider specifically contributions and limitations of STEM for the investigation of amyloid assembly pathways, fibril polymorphisms and structural models of amyloid fibrils. This type of microscopy provides the only method to directly measure the mass-per-length (MPL) of individual filaments. Made on both in vitro assembled and ex vivo samples, STEM mass measurements have illuminated the hierarchical relationships between amyloid fibrils and revealed that polymorphic fibrils and various globular oligomers can assemble simultaneously from a single polypeptide. The MPLs also impose strong constraints on possible packing schemes, assisting in molecular model building when combined with high-resolution methods like solid-state nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR).

  13. Nanomaterial datasets to advance tomography in scanning transmission electron microscopy

    Science.gov (United States)

    Levin, Barnaby D. A.; Padgett, Elliot; Chen, Chien-Chun; Scott, M. C.; Xu, Rui; Theis, Wolfgang; Jiang, Yi; Yang, Yongsoo; Ophus, Colin; Zhang, Haitao; Ha, Don-Hyung; Wang, Deli; Yu, Yingchao; Abruña, Hector D.; Robinson, Richard D.; Ercius, Peter; Kourkoutis, Lena F.; Miao, Jianwei; Muller, David A.; Hovden, Robert

    2016-06-01

    Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co2P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180° tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of post-processing and visualization techniques. Researchers interested in creating novel data processing and reconstruction algorithms will now have access to state of the art experimental test data.

  14. A 10 mK scanning tunneling microscope operating in ultra high vacuum and high magnetic fields.

    Science.gov (United States)

    Assig, Maximilian; Etzkorn, Markus; Enders, Axel; Stiepany, Wolfgang; Ast, Christian R; Kern, Klaus

    2013-03-01

    We present design and performance of a scanning tunneling microscope (STM) that operates at temperatures down to 10 mK providing ultimate energy resolution on the atomic scale. The STM is attached to a dilution refrigerator with direct access to an ultra high vacuum chamber allowing in situ sample preparation. High magnetic fields of up to 14 T perpendicular and up to 0.5 T parallel to the sample surface can be applied. Temperature sensors mounted directly at the tip and sample position verified the base temperature within a small error margin. Using a superconducting Al tip and a metallic Cu(111) sample, we determined an effective temperature of 38 ± 1 mK from the thermal broadening observed in the tunneling spectra. This results in an upper limit for the energy resolution of ΔE = 3.5 kBT = 11.4 ± 0.3 μeV. The stability between tip and sample is 4 pm at a temperature of 15 mK as demonstrated by topography measurements on a Cu(111) surface.

  15. A 10Â mK scanning tunneling microscope operating in ultra high vacuum and high magnetic fields

    Science.gov (United States)

    Assig, Maximilian; Etzkorn, Markus; Enders, Axel; Stiepany, Wolfgang; Ast, Christian R.; Kern, Klaus

    2013-03-01

    We present design and performance of a scanning tunneling microscope (STM) that operates at temperatures down to 10 mK providing ultimate energy resolution on the atomic scale. The STM is attached to a dilution refrigerator with direct access to an ultra high vacuum chamber allowing in situ sample preparation. High magnetic fields of up to 14 T perpendicular and up to 0.5 T parallel to the sample surface can be applied. Temperature sensors mounted directly at the tip and sample position verified the base temperature within a small error margin. Using a superconducting Al tip and a metallic Cu(111) sample, we determined an effective temperature of 38 ± 1 mK from the thermal broadening observed in the tunneling spectra. This results in an upper limit for the energy resolution of ΔE = 3.5kBT = 11.4 ± 0.3 μeV. The stability between tip and sample is 4 pm at a temperature of 15 mK as demonstrated by topography measurements on a Cu(111) surface.

  16. Direct Observation of Protein Microcrystals in Crystallization Buffer by Atmospheric Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Chikara Sato

    2012-08-01

    Full Text Available X-ray crystallography requires high quality crystals above a given size. This requirement not only limits the proteins to be analyzed, but also reduces the speed of the structure determination. Indeed, the tertiary structures of many physiologically important proteins remain elusive because of the so-called “crystallization bottleneck”. Once microcrystals have been obtained, crystallization conditions can be optimized to produce bigger and better crystals. However, the identification of microcrystals can be difficult due to the resolution limit of optical microscopy. Electron microscopy has sometimes been utilized instead, with the disadvantage that the microcrystals usually must be observed in vacuum, which precludes the usage for crystal screening. The atmospheric scanning electron microscope (ASEM allows samples to be observed in solution. Here, we report the use of this instrument in combination with a special thin-membrane dish with a crystallization well. It was possible to observe protein crystals of lysozyme, lipase B and a histone chaperone TAF-Iβ in crystallization buffers, without the use of staining procedures. The smallest crystals observed with ASEM were a few µm in width, and ASEM can be used with non-transparent solutions. Furthermore, the growth of salt crystals could be monitored in the ASEM, and the difference in contrast between salt and protein crystals made it easy to distinguish between these two types of microcrystals. These results indicate that the ASEM could be an important new tool for the screening of protein microcrystals.

  17. Vacuum ultraviolet circularly polarized coherent femtosecond pulses from laser seeded relativistic electrons

    Directory of Open Access Journals (Sweden)

    N. Čutić

    2011-03-01

    Full Text Available We have demonstrated the generation of circularly polarized coherent light pulses at 66 nm wavelength by combining laser seeding at 263 nm of a 375 MeV relativistic electron bunch with subsequent coherent harmonic generation from an elliptical undulator of APPLE-II type. Coherent pulses at higher harmonics in linear polarization have been produced and recorded up to the sixth order (44 nm. The duration of the generated pulses depends on the temporal overlap of the initial seed laser pulse and the electron bunch and was on the order of 200 fs. Currently, this setup is the only source worldwide producing coherent fs-light pulses with variable polarization in the vacuum ultraviolet.

  18. Design and performance of an ultra-high vacuum scanning tunneling microscope operating at dilution refrigerator temperatures and high magnetic fields

    Science.gov (United States)

    Misra, S.; Zhou, B. B.; Drozdov, I. K.; Seo, J.; Urban, L.; Gyenis, A.; Kingsley, S. C. J.; Jones, H.; Yazdani, A.

    2013-10-01

    We describe the construction and performance of a scanning tunneling microscope capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T) magnetic fields. The fully ultra-high vacuum system features visual access to a two-sample microscope stage at the end of a bottom-loading dilution refrigerator, which facilitates the transfer of in situ prepared tips and samples. The two-sample stage enables location of the best area of the sample under study and extends the experiment lifetime. The successful thermal anchoring of the microscope, described in detail, is confirmed through a base temperature reading of 20 mK, along with a measured electron temperature of 250 mK. Atomically resolved images, along with complementary vibration measurements, are presented to confirm the effectiveness of the vibration isolation scheme in this instrument. Finally, we demonstrate that the microscope is capable of the same level of performance as typical machines with more modest refrigeration by measuring spectroscopic maps at base temperature both at zero field and in an applied magnetic field.

  19. Scanning electron microscope automatic defect classification of process induced defects

    Science.gov (United States)

    Wolfe, Scott; McGarvey, Steve

    2017-03-01

    With the integration of high speed Scanning Electron Microscope (SEM) based Automated Defect Redetection (ADR) in both high volume semiconductor manufacturing and Research and Development (R and D), the need for reliable SEM Automated Defect Classification (ADC) has grown tremendously in the past few years. In many high volume manufacturing facilities and R and D operations, defect inspection is performed on EBeam (EB), Bright Field (BF) or Dark Field (DF) defect inspection equipment. A comma separated value (CSV) file is created by both the patterned and non-patterned defect inspection tools. The defect inspection result file contains a list of the inspection anomalies detected during the inspection tools' examination of each structure, or the examination of an entire wafers surface for non-patterned applications. This file is imported into the Defect Review Scanning Electron Microscope (DRSEM). Following the defect inspection result file import, the DRSEM automatically moves the wafer to each defect coordinate and performs ADR. During ADR the DRSEM operates in a reference mode, capturing a SEM image at the exact position of the anomalies coordinates and capturing a SEM image of a reference location in the center of the wafer. A Defect reference image is created based on the Reference image minus the Defect image. The exact coordinates of the defect is calculated based on the calculated defect position and the anomalies stage coordinate calculated when the high magnification SEM defect image is captured. The captured SEM image is processed through either DRSEM ADC binning, exporting to a Yield Analysis System (YAS), or a combination of both. Process Engineers, Yield Analysis Engineers or Failure Analysis Engineers will manually review the captured images to insure that either the YAS defect binning is accurately classifying the defects or that the DRSEM defect binning is accurately classifying the defects. This paper is an exploration of the feasibility of the

  20. Automated Quantitative Rare Earth Elements Mineralogy by Scanning Electron Microscopy

    Science.gov (United States)

    Sindern, Sven; Meyer, F. Michael

    2016-09-01

    Increasing industrial demand of rare earth elements (REEs) stems from the central role they play for advanced technologies and the accelerating move away from carbon-based fuels. However, REE production is often hampered by the chemical, mineralogical as well as textural complexity of the ores with a need for better understanding of their salient properties. This is not only essential for in-depth genetic interpretations but also for a robust assessment of ore quality and economic viability. The design of energy and cost-efficient processing of REE ores depends heavily on information about REE element deportment that can be made available employing automated quantitative process mineralogy. Quantitative mineralogy assigns numeric values to compositional and textural properties of mineral matter. Scanning electron microscopy (SEM) combined with a suitable software package for acquisition of backscatter electron and X-ray signals, phase assignment and image analysis is one of the most efficient tools for quantitative mineralogy. The four different SEM-based automated quantitative mineralogy systems, i.e. FEI QEMSCAN and MLA, Tescan TIMA and Zeiss Mineralogic Mining, which are commercially available, are briefly characterized. Using examples of quantitative REE mineralogy, this chapter illustrates capabilities and limitations of automated SEM-based systems. Chemical variability of REE minerals and analytical uncertainty can reduce performance of phase assignment. This is shown for the REE phases parisite and synchysite. In another example from a monazite REE deposit, the quantitative mineralogical parameters surface roughness and mineral association derived from image analysis are applied for automated discrimination of apatite formed in a breakdown reaction of monazite and apatite formed by metamorphism prior to monazite breakdown. SEM-based automated mineralogy fulfils all requirements for characterization of complex unconventional REE ores that will become

  1. Visualizing bone porosities using a tabletop scanning electron microscope

    Science.gov (United States)

    Krishnamoorthy, D.; DaPonte, J.; Broadbridge, C. C.; Daniel, D.; Alter, L.

    2010-04-01

    Pores are naturally occurring entities in bone. Changes in pore size and number are often associated with diseases such as Osteoporosis and even microgravity during spaceflight. Studying bone perforations may yield great insight into bone's material properties, including bone density and may contribute to identifying therapies to halt or potentially reverse bone loss. Current technologies used in this field include nuclear magnetic resonance, micro-computed tomography and the field emission scanning electron microscope (FE-SEM) 2, 5. However, limitations in each method limit further advancement. The objective of this study was to assess the effectiveness of using a new generation of analytical instruments, the TM-1000 tabletop, SEM with back-scatter electron (BSE) detector, to analyze cortical bone porosities. Hind limb unloaded and age-based controlled mouse femurs were extracted and tested in vitro for changes in pores on the periosteal surface. An important advantage of using the tabletop is the simplified sample preparation that excludes extra coatings, dehydration and fixation steps that are otherwise required for conventional SEM. For quantitative data, pores were treated as particles in order to use an analyze particles feature in the NIH ImageJ software. Several image-processing techniques for background smoothing, thresholding and filtering were employed to produce a binary image suitable for particle analysis. It was hypothesized that the unloaded bones would show an increase in pore area, as the lack of mechanical loading would affect bone-remodeling processes taking place in and around pores. Preliminary results suggest only a slight different in frequency but not in size of pores between unloaded and control femurs.

  2. Cryo-planing for cryo-scanning electron microscopy.

    Science.gov (United States)

    Nijsse, J; van Aelst, A C

    1999-01-01

    In the past decade, investigators of cryo-planing for low-temperature scanning electron microscopy (cryo-SEM) have developed techniques that enable observations of flat sample surfaces. This study reviews these sample preparation techniques, compares and contrasts their results, and introduces modifications that improve results from cryo-planing. A prerequisite for all successful cryo-planing required a stable attachment of the specimen to a holder. In most cases, clamping with a screw mechanism and using indium as space-filler sufficed. Once this problem was solved, any of three existing cryo-planing methods could be used to provide successful results: cryo-milling, microtomy in a cold room, and cryo-ultramicrotomy. This study introduces modifications to the cryo-planing technique that produces flat surfaces of any desired plane through a specimen. These flat surfaces of frozen, fully hydrated samples can be used to improve observations from cryo-SEM as well as to enhance results from x-ray microanalysis and (digital) image analysis. Cryo-planing results of chrysanthemum (Dendranthema x grandiflorum Tzvelev) stems, hazel (Corylus avelane L.) stems, and repeseed (Brassica napus L.) pistils are presented to illustrate the use of the planing method on fibrous, hard, and delicate materials, respectively.

  3. Non-thermal plasma mills bacteria: Scanning electron microscopy observations

    Energy Technology Data Exchange (ETDEWEB)

    Lunov, O., E-mail: lunov@fzu.cz; Churpita, O.; Zablotskii, V.; Jäger, A.; Dejneka, A. [Institute of Physics AS CR, Prague 18221 (Czech Republic); Deyneka, I. G.; Meshkovskii, I. K. [St. Petersburg State University of Information Technologies, Mechanics and Optics, St. Petersburg 197101 (Russian Federation); Syková, E. [Institute of Experimental Medicine AS CR, Prague 14220 (Czech Republic); Kubinová, Š. [Institute of Physics AS CR, Prague 18221 (Czech Republic); Institute of Experimental Medicine AS CR, Prague 14220 (Czech Republic)

    2015-02-02

    Non-thermal plasmas hold great promise for a variety of biomedical applications. To ensure safe clinical application of plasma, a rigorous analysis of plasma-induced effects on cell functions is required. Yet mechanisms of bacteria deactivation by non-thermal plasma remain largely unknown. We therefore analyzed the influence of low-temperature atmospheric plasma on Gram-positive and Gram-negative bacteria. Using scanning electron microscopy, we demonstrate that both Gram-positive and Gram-negative bacteria strains in a minute were completely destroyed by helium plasma. In contrast, mesenchymal stem cells (MSCs) were not affected by the same treatment. Furthermore, histopathological analysis of hematoxylin and eosin–stained rat skin sections from plasma–treated animals did not reveal any abnormalities in comparison to control ones. We discuss possible physical mechanisms leading to the shred of bacteria under non-thermal plasma irradiation. Our findings disclose how helium plasma destroys bacteria and demonstrates the safe use of plasma treatment for MSCs and skin cells, highlighting the favorability of plasma applications for chronic wound therapy.

  4. Somatic Embryos in Catharanthus roseus: A Scanning Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Junaid ASLAM

    2014-06-01

    Full Text Available Catharanthus roseus (L. G. Don is an important medicinal plant as it contains several anti-cancerous compounds, like vinblastine and vincristine. Plant tissue culture technology (organogenesis and embryogenesis has currently been used in fast mass propagating raw materials for secondary metabolite synthesis. In this present communication, scanning electron microscopic (SEM study of somatic embryos was conducted and discussed. The embryogenic callus was first induced from hypocotyls of in vitro germinated seeds on which somatic embryos, differentiated in numbers, particularly on 2,4-D (1.0 mg/L Murashige and Skoog (MS was medium. To understand more about the regeneration method and in vitro formed embryos SEM was performed. The SEM study revealed normal somatic embryo origin and development from globular to heart-, torpedo- and then into cotyledonary-stage of embryos. At early stage, the embryos were clustered together in a callus mass and could not easily be detached from the parental tissue. The embryos were often long cylindrical structure with or without typical notch at the tip. Secondary embryos were also formed on primary embryo structure. The advanced cotyledonary embryos showed prominent roots and shoot axis, which germinated into plantlets. The morphology, structure and other details of somatic embryos at various stages were presented.

  5. An overview on bioaerosols viewed by scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wittmaack, K. [GSF-National Research Centre for Environment and Health, Institute of Radiation Protection, 85758 Neuherberg (Germany)]. E-mail: wittmaack@gsf.de; Wehnes, H. [GSF-National Research Centre for Environment and Health, Institute of Pathology, 85758 Neuherberg (Germany); Heinzmann, U. [GSF-National Research Centre for Environment and Health, Institute of Pathology, 85758 Neuherberg (Germany); Agerer, R. [Ludwig-Maximilians University Munich, Department Biology, Biodiversity Research: Mycology, Menzinger Stasse 67, 80638 Munich (Germany)

    2005-06-15

    Bioaerosols suspended in ambient air were collected with single-stage impactors at a semiurban site in southern Germany during late summer and early autumn. Sampling was mostly carried out at a nozzle velocity of 35 m/s, corresponding to a minimum aerodynamic diameter (cut-off diameter) of aerosol particles of 0.8 {mu}m. The collected particles, sampled for short periods ({approx}15 min) to avoid pile-up, were characterized by scanning electron microscopy (SEM). The observed bioaerosols include brochosomes, fungal spores, hyphae, insect scales, hairs of plants and, less commonly, bacteria and epicuticular wax. Brochosomes, which serve as a highly water repellent body coating of leafhoppers, are hollow spheroids with diameters around 400 nm, resembling C{sub 60} or footballs (soccer balls). They are usually airborne not as individuals but in the form of large clusters containing up to 10,000 individual species or even more. Various types of spores and scales were observed, but assignment turned out be difficult due to the large number of fungi and insects from which they may have originated. Pollens were observed only once. The absence these presumably elastic particles suggests that they are frequently lost, at the comparatively high velocities, due to bounce-off from the nonadhesive impaction surfaces.

  6. Scanning electron microscopy of eggs of Sabethes cyaneus.

    Science.gov (United States)

    Santos-Mallet, Jacenir; Sarmento, Juliana Soares; Alencar, Jeronimo; Müller, Gerson Azulim; Oliveira, Eliana Medeiros; Foster, Woodbridge A; Marcondes, Carlos Brisola

    2013-03-01

    Mosquitoes of the Neotropical genus Sabethes, some species of which are yellow fever vectors, most often develop through the immature stages in tree holes. Sabethes eggs have not been previously characterized using scanning electron microscopy. Eggs of Sabethes cyaneus (length: 349.6 +/- 2.7 microm; width: 172.6 +/- 1.14 microm; n = 10) are almost biconical when examined from the top. From a lateral perspective 2 surfaces can be seen. One surface is smooth and more convex, whereas the other is less convex and partially covered by a network from which many fungiform tubercles arise. The micropyle is situated on the smooth surface of the pointed anterior tip and is surrounded by an irregular row of tubercles, some of which are leaf shaped. No structures possibly involved in adhesion to surfaces are visible. When hatching, the egg splits dorsoventrally approximately two-thirds of the length from the anterior end. The tubercles appear to be water repellent, and the more convex/smoother surface is downturned, and this position on water was confirmed by direct observation. The eggs float free on the water surface.

  7. Scanning electron microscopy applied to seed-borne fungi examination.

    Science.gov (United States)

    Alves, Marcelo de Carvalho; Pozza, Edson Ampélio

    2009-07-01

    The aim of this study was to test the standard scanning electron microscopy (SEM) as a potential alternative to study seed-borne fungi in seeds, by two different conditions of blotter test and water restriction treatment. In the blotter test, seeds were subjected to conditions that enabled pathogen growth and expression, whereas the water restriction method consisted in preventing seed germination during the incubation period, resulting in the artificial inoculation of fungi. In the first condition, seeds of common bean (Phaseolus vulgaris L.), maize (Zea mays L.), and cotton (Gossypium hirsutum L.) were submitted to the standard blotter test and then prepared and observed with SEM. In the second condition, seeds of cotton (G. hirsutum), soybean (Glycine max L.), and common bean (P. vulgaris L.) were, respectively, inoculated with Colletotrichum gossypii var. cephalosporioides, Colletotrichum truncatum, and Colletotrichum lindemuthianum by the water restriction technique, followed by preparation and observation with SEM. The standard SEM methodology was adopted to prepare the specimens. Considering the seeds submitted to the blotter test, it was possible to identify Fusarium sp. on maize, C. gossypii var. cephalosporioides, and Fusarium oxysporum on cotton, Aspergillus flavus, Penicillium sp., Rhizopus sp., and Mucor sp. on common bean. Structures of C. gossypii var. cephalosporioides, C. truncatum, and C. lindemuthianum were observed in the surface of inoculated seeds. (c) 2009 Wiley-Liss, Inc.

  8. Scanning electron microscopy of the neuropathology of murine cerebral malaria

    Directory of Open Access Journals (Sweden)

    Brenneis Christian

    2006-11-01

    Full Text Available Abstract Background The mechanisms leading to death and functional impairments due to cerebral malaria (CM are yet not fully understood. Most of the knowledge about the pathomechanisms of CM originates from studies in animal models. Though extensive histopathological studies of the murine brain during CM are existing, alterations have not been visualized by scanning electron microscopy (SEM so far. The present study investigates the neuropathological features of murine CM by applying SEM. Methods C57BL/6J mice were infected with Plasmodium berghei ANKA blood stages. When typical symptoms of CM developed perfused brains were processed for SEM or light microscopy, respectively. Results Ultrastructural hallmarks were disruption of vessel walls, parenchymal haemorrhage, leukocyte sequestration to the endothelium, and diapedesis of macrophages and lymphocytes into the Virchow-Robin space. Villous appearance of observed lymphocytes were indicative of activated state. Cerebral oedema was evidenced by enlargement of perivascular spaces. Conclusion The results of the present study corroborate the current understanding of CM pathophysiology, further support the prominent role of the local immune system in the neuropathology of CM and might expose new perspectives for further interventional studies.

  9. [Scanning electron microscopy findings in titanium middle ear prostheses].

    Science.gov (United States)

    Schwager, K

    2000-12-01

    Titanium as a biomaterial in ossicular replacement has widely spread within the last couple of years. 23 prostheses (12 PORPs, partial ossicular replacement prostheses and 11 TORPs total ossicular replacement prostheses) removed during revision surgery were studied using scanning electron microscopy. The average implantation time was 8 (range 3-15) months. The specimens were investigated regarding tissue growth, epithelialization, inflammation and cellular signs of rejection. Only few prostheses were totally covered by connective tissue or epithelium due to technical problems in removing the implant and the covering tissue as one specimen. But this offered the possibility to study the interface at the edges where the tissue was torn off. The connective tissue looked unremarkable. Polygonal squamous epithelium was detected on several implants. Respiratory epithelium with ciliated cells and mucus producing goblet cells was seen in two specimens. In cases of cholesteatoma or protrusion the explanted prostheses showed typical rosette-like formation of hornifying squamous epithelium. According to underlying disease a lymphocytic infiltration could be seen. There were no cellular signs of incompatibility noticed neither macrophages nor foreign body giant cells. From these investigations titanium seems to be a favorable biomaterial for ossicular replacement with good acceptance also in an implantation site showing chronic inflammation.

  10. Scanning electron microscopy investigations regarding Adonis vernalis L. flower morphology

    Directory of Open Access Journals (Sweden)

    Irina Neta GOSTIN

    2009-11-01

    Full Text Available The floral morphology of Adonis vernalis L. was observed with a scanning electron microscope (SEM. The investigations are important to clarify some taxonomical problems and also could provide useful diagnostic elements for the identification of this medicinal plant in powdered materials. All floral organs are initiated spirally and centripetally and develop centripetally. The petals (8-12 are shorter than the sepals (5-6 in early developmental stages. The petals are disposed on spiral (with 3-4 whorls. The stamens (numerous are unbranched and reach maturity centripetally; they are free of the perianth. The anther walls consisting of a single layer epidermis in the anther wall surrounding the sporagenous tissue, one row of endothecium, two to four rows of middle layer and one row of tapetum layer. In the anther walls, the tapetal cells, by glandular type, persist later in ontogenesis. Pollen grains are tricolpate with echinate surface. The gynoecium is multiple, apocarpous with distinct carpels. The carpels are ascidiate from the beginning. At the base of each carpel, numerousness short, unicellular, trichomes are present. The stigma differentiates as two crests along the ventral slit of the ovary. Each carpel contains a single ovule inside the ovary cavity. The mature ovule is anatropous, with two integuments. It is almost parallel to the funicle.

  11. Special raster scanning for reduction of charging effects in scanning electron microscopy.

    Science.gov (United States)

    Suzuki, Kazuhiko; Oho, Eisaku

    2014-01-01

    A special raster scanning (SRS) method for reduction of charging effects is developed for the field of SEM. Both a conventional fast scan (horizontal direction) and an unusual scan (vertical direction) are adopted for acquiring raw data consisting of many sub-images. These data are converted to a proper SEM image using digital image processing techniques. About sharpness of the image and reduction of charging effects, the SRS is compared with the conventional fast scan (with frame-averaging) and the conventional slow scan. Experimental results show the effectiveness of SRS images. By a successful combination of the proposed scanning method and low accelerating voltage (LV)-SEMs, it is expected that higher-quality SEM images can be more easily acquired by the considerable reduction of charging effects, while maintaining the resolution. © 2013 Wiley Periodicals, Inc.

  12. Separating and recycling metals from mixed metallic particles of crushed electronic wastes by vacuum metallurgy.

    Science.gov (United States)

    Zhan, Lu; Xu, Zhenming

    2009-09-15

    During the treatment of electronic wastes, a crushing process is usually used to strip metals from various base plates. Several methods have been applied to separate metals from nonmetals. However, mixed metallic particles obtained from these processes are still a mixture of various metals, including some toxic heavy metals such as lead and cadmium. With emphasis on recovering copper and other precious metals, there have hitherto been no satisfactory methods to recover these toxic metals. In this paper, the criterion of separating metals from mixed metallic particles by vacuum metallurgy is built. The results show that the metals with high vapor pressure have been almost recovered completely, leading to a considerable reduction of environmental pollution. In addition, the purity of copper in mixed particles has been improved from about 80 wt % to over 98 wt %.

  13. Improved Visualization of Vertebrate Nuclear Pore Complexes by Field Emission Scanning Electron Microscopy

    National Research Council Canada - National Science Library

    Shaulov, Lihi; Harel, Amnon

    2012-01-01

    Field emission scanning electron microscopy (FESEM) can provide high-resolution three-dimensional surface imaging of many biological structures, including nuclear envelopes and nuclear pore complexes (NPCs...

  14. SCANNING ELECTRON MICROSCOPY OF THE RAT ADRENAL GLAND AFTER SURGICAL LASER EXPOSURE

    Directory of Open Access Journals (Sweden)

    K. G. Kemoklidze

    2016-01-01

    Full Text Available Aim. We studied via low vacuum scanning electron microscopy the effects of a surgical laser exposure to adrenal glands and results of regeneration processes after. Materials and methods.Purpose of this work is modeling of effects of the removal with a surgical laser a pathological focus in the adrenal glands. For this Wistar male rat (n = 19 adrenal glands were researched without the laser exposure, immediately after it and 1 month later. Results. Immediately after exposure occurs laser ablation crater with rough edges and melted surface penetrated by equidistant pores, which are footprints of blood vessels. Beneath of the surface are numerous vaporizationbubbles. Around the crater, the surface wrinkles and sags due to decreased ability to retain water. 1 month after the laser damage, the affected area tightened by a scar. Its coarse bundles of collagen fibers braid shapeless lumps of coal and caverns. Tissues with normal appearance are close to the scar, both outside and inside of the organ. The wrinkling and the sagging are absent. The undamaged organ part has retained the previous shape, without hypertrophies. The damaged part has shrunk. The nature of the regeneration processes indicates a low probability of a relapse after the destruction of a pathological focus via the surgical laser exposure.

  15. Regenerating titanium ventricular assist device surfaces after gold/palladium coating for scanning electron microscopy.

    Science.gov (United States)

    Achneck, Hardean E; Serpe, Michael J; Jamiolkowski, Ryan M; Eibest, Leslie M; Craig, Stephen L; Lawson, Jeffrey H

    2010-01-01

    Titanium is one of the most commonly used materials for implantable devices in humans. Scanning electron microscopy (SEM) serves as an important tool for imaging titanium surfaces and analyzing cells and other organic matter adhering to titanium implants. However, high-vacuum SEM imaging of a nonconductive sample requires a conductive coating on the surface. A gold/palladium coating is commonly used and to date no method has been described to "clean" such gold/palladium covered surfaces for repeated experiments without etching the titanium itself. This constitutes a major problem with titanium-based implantable devices which are very expensive and thus in short supply. Our objective was to devise a protocol to regenerate titaniumsurfaces after SEM analysis. In a series of experiments, titanium samples from implantable cardiac assist devices were coated with fibronectin, seeded with cells and then coated with gold/palladium for SEM analysis. X-ray photoelectron spectroscopy spectra were obtained before and after five different cleaning protocols. Treatment with aqua regia (a 1:3 solution of concentrated nitric and hydrochloric acid), with or without ozonolysis, followed by sonication in soap solution and sonication in deionized water, allowed regenerating titanium surfaces to their original state. Atomic force microscopy confirmed that the established protocol did not alter the titanium microstructure. The protocol described herein is applicable to almost all titanium surfaces used in biomedical sciences and because of its short exposure time to aqua regia, will likely work for many titanium alloys as well. (c) 2009 Wiley-Liss, Inc.

  16. Scanning Electron Microscope-Cathodoluminescence Analysis of Rare-Earth Elements in Magnets.

    Science.gov (United States)

    Imashuku, Susumu; Wagatsuma, Kazuaki; Kawai, Jun

    2016-02-01

    Scanning electron microscope-cathodoluminescence (SEM-CL) analysis was performed for neodymium-iron-boron (NdFeB) and samarium-cobalt (Sm-Co) magnets to analyze the rare-earth elements present in the magnets. We examined the advantages of SEM-CL analysis over conventional analytical methods such as SEM-energy-dispersive X-ray (EDX) spectroscopy and SEM-wavelength-dispersive X-ray (WDX) spectroscopy for elemental analysis of rare-earth elements in NdFeB magnets. Luminescence spectra of chloride compounds of elements in the magnets were measured by the SEM-CL method. Chloride compounds were obtained by the dropwise addition of hydrochloric acid on the magnets followed by drying in vacuum. Neodymium, praseodymium, terbium, and dysprosium were separately detected in the NdFeB magnets, and samarium was detected in the Sm-Co magnet by the SEM-CL method. In contrast, it was difficult to distinguish terbium and dysprosium in the NdFeB magnet with a dysprosium concentration of 1.05 wt% by conventional SEM-EDX analysis. Terbium with a concentration of 0.02 wt% in an NdFeB magnet was detected by SEM-CL analysis, but not by conventional SEM-WDX analysis. SEM-CL analysis is advantageous over conventional SEM-EDX and SEM-WDX analyses for detecting trace rare-earth elements in NdFeB magnets, particularly dysprosium and terbium.

  17. Calculations of secondary electron yield of graphene coated copper for vacuum electronic applications

    Directory of Open Access Journals (Sweden)

    H. K. A. Nguyen

    2018-01-01

    Full Text Available The suppression of secondary electron yield (SEY which can possibly lead to multipactor is an important goal for several applications. Though some techniques have focused on geometric modifications to lower the SEY, the use of graphene coatings as thin as a few monolayers is a promising new development that deserves attention either as a standalone technique or in concert with geometric alterations. Here we report on Monte Carlo based numerical studies of SEY on graphene coated copper with comparisons to recent experimental data. Our predicted values are generally in good agreement with reported measurements. Suppression of the secondary electron yield by as much as 50 percent (over copper with graphene coating is predicted at energies below 125 eV, and bodes well for multipactor suppression in radio frequency applications.

  18. Calculations of secondary electron yield of graphene coated copper for vacuum electronic applications

    Science.gov (United States)

    Nguyen, H. K. A.; Mankowski, J.; Dickens, J. C.; Neuber, A. A.; Joshi, R. P.

    2018-01-01

    The suppression of secondary electron yield (SEY) which can possibly lead to multipactor is an important goal for several applications. Though some techniques have focused on geometric modifications to lower the SEY, the use of graphene coatings as thin as a few monolayers is a promising new development that deserves attention either as a standalone technique or in concert with geometric alterations. Here we report on Monte Carlo based numerical studies of SEY on graphene coated copper with comparisons to recent experimental data. Our predicted values are generally in good agreement with reported measurements. Suppression of the secondary electron yield by as much as 50 percent (over copper) with graphene coating is predicted at energies below 125 eV, and bodes well for multipactor suppression in radio frequency applications.

  19. Autofocus on moving object in scanning electron microscope.

    Science.gov (United States)

    Kudryavtsev, Andrey V; Dembélé, Sounkalo; Piat, Nadine

    2017-11-01

    The sharpness of the images coming from a Scanning Electron Microscope (SEM) is a very important property for many computer vision applications at micro- and nanoscale. It represents how much object details are distinctive in the images: the object may be perceived sharp or blurred. Image sharpness highly depends on the value of focal distance, or working distance in the case of the SEM. Autofocus is the technique allowing to automatically adjust the working distance to maximize the sharpness. Most of the existing algorithms allows working only with a static object which is enough for the tasks of visualization, manual microanalysis or microcharacterization. These applications work with a low frame rate, less than 1 Hz, that guarantees a low level of noise. However, static autofocus can not be used for samples performing continuous 3D motion, which is the case of robotic applications where it is required to carry out a continuous 3D position measurement, e.g., nano-assembly or nanomanipulation. Moreover, in addition to constantly keeping object in focus while it is moving, it is required to perform the operation at high frame rate. The approach offering both these possibilities is presented in this paper and is referred as dynamic autofocus. The presented solution is based on stochastic optimization techniques. It allows tracking the maximum of the sharpness of the images without sweep and without training. It works under uncertainty conditions: presence of noise in images, unknown maximal sharpness and unknown 3D motion of the specimen. The experiments, that were performed with noisy images at high frame rate (5 Hz), were conducted on a Carl Zeiss Auriga 60 FE-SEM. They prove the robustness of the algorithm with respect to the variation of optimization parameters, object speed and magnification. Moreover, it is invariant to the object structure and its variation in time. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Candida albicans morphologies revealed by scanning electron microscopy analysis

    Directory of Open Access Journals (Sweden)

    M. Staniszewska

    2013-09-01

    Full Text Available Scanning electron microscope (SEM observations were used to analyze particular morphologies of Candida albicans clinical isolate (strain 82 and mutants defective in hyphae-promoting genes EFG1 (strain HLC52 and/ or CPH1 (strains HLC54 and Can16. Transcription factors Efg1 and Cph1 play role in regulating filamentation and adhesion of C. albicans' morphologies. Comparative analysis of such mutants and clinical isolate showed that Efg1 is required for human serum-induced cell growth and morphological switching. In the study, distinct differences between ultrastructural patterns of clinical strain's and null mutants' morphologies were observed (spherical vs tube-like blastoconidia, or solid and fragile constricted septa vs only the latter observed in strains with EFG1 deleted. In addition, wild type strain displayed smooth colonies of cells in comparison to mutants which exhibited wrinkled phenotype. It was observed that blastoconidia of clinical strain exhibited either polarly or randomly located budding. Contrariwise, morphotypes of mutants showed either multiple polar budding or a centrally located single bud scar (mother-daughter cell junction distinguishing tube-like yeast/ pseudohyphal growth (the length-to-width ratios larger than 1.5. In their planktonic form of growth, blastoconidia of clinical bloodstream isolate formed constitutively true hyphae under undiluted human serum inducing conditions. It was found that true hyphae are essential elements for developing structural integrity of conglomerate, as mutants displaying defects in their flocculation and conglomerate-forming abilities in serum. While filamentation is an important virulence trait in C. albicans the true hyphae are the morphologies which may be expected to play a role in bloodstream infections.

  1. Neural Network for Nanoscience Scanning Electron Microscope Image Recognition.

    Science.gov (United States)

    Modarres, Mohammad Hadi; Aversa, Rossella; Cozzini, Stefano; Ciancio, Regina; Leto, Angelo; Brandino, Giuseppe Piero

    2017-10-16

    In this paper we applied transfer learning techniques for image recognition, automatic categorization, and labeling of nanoscience images obtained by scanning electron microscope (SEM). Roughly 20,000 SEM images were manually classified into 10 categories to form a labeled training set, which can be used as a reference set for future applications of deep learning enhanced algorithms in the nanoscience domain. The categories chosen spanned the range of 0-Dimensional (0D) objects such as particles, 1D nanowires and fibres, 2D films and coated surfaces, and 3D patterned surfaces such as pillars. The training set was used to retrain on the SEM dataset and to compare many convolutional neural network models (Inception-v3, Inception-v4, ResNet). We obtained compatible results by performing a feature extraction of the different models on the same dataset. We performed additional analysis of the classifier on a second test set to further investigate the results both on particular cases and from a statistical point of view. Our algorithm was able to successfully classify around 90% of a test dataset consisting of SEM images, while reduced accuracy was found in the case of images at the boundary between two categories or containing elements of multiple categories. In these cases, the image classification did not identify a predominant category with a high score. We used the statistical outcomes from testing to deploy a semi-automatic workflow able to classify and label images generated by the SEM. Finally, a separate training was performed to determine the volume fraction of coherently aligned nanowires in SEM images. The results were compared with what was obtained using the Local Gradient Orientation method. This example demonstrates the versatility and the potential of transfer learning to address specific tasks of interest in nanoscience applications.

  2. Environmental scanning electron microscopy observation of the ultrastructure of Demodex.

    Science.gov (United States)

    Jing, Xu; Shuling, Guo; Ying, Liu

    2005-12-01

    In this study, numbers of Demodex of hair follicles and sebaceous glands were prepared and the ultrastructure (especially the mouthparts) of Demodex was observed firstly with environmental scanning electron microscopy (ESEM). The most suitable treatment methods and optimal environmental condition for observing the genus samples were found. The samples were washed with detergent and rinsed with distilled water, and then were taken to the specimen stage, on which there was carbon adhesive tape, using special tools. When the temperature was at 5 degrees C and chamber pressure at 5 mbar respectively, the surface of the samples could be fully imaged without covering water or dehydration. The sample surfaces were plump and clear without postmortem changes and charging artifacts. Detailed information about each part of Demodex was observed by ESEM, and clear three-dimensional images were recorded. The mouthparts of D. folliculorum were composed of a complex set of structures, which included a round oral opening, a sharp oral needle, and a special hypostome that looked like a longitudinal spindle in the central position. On the end segment of palpus, there were seven strong palpal claws located on each side of the mouthparts. D. folliculorum had special piercing mouthparts, while the mouthparts of D. brevis were a simpler structure. We could not observe the oral needle of D. brevis, and there were only five pairs of palpal claws on the end segment of palpus. The offensive organs of Demodex resulted in its pathogenic effects. After studying hundreds of Demodex, we identified both female and male species of D. folliculorum, but only females of D. brevis in our sample. (c) 2005 Wiley-Liss, Inc.

  3. Kinetics of Evaporation of Alloying Elements under Vacuum: Application to Ti alloys in Electron Beam Melting

    Science.gov (United States)

    Choi, Wonjin; Jourdan, Julien; Matveichev, Alexey; Jardy, Alain; Bellot, Jean-Pierre

    2017-09-01

    Vacuum metallurgical processes such as the electron beam melting are highly conducive to volatilization. In titanium processing, it concerns the alloying elements which show a high vapor pressure with respect to titanium matrix, such as Al. Two different experimental approaches using a laboratory electron beam furnace have been developed for the estimation of volatilization rate and activity coefficient of Al in Ti64. The first innovative method is based on the deposition rate of Al on Si wafers located at different angles θ above the liquid bath. We found that a deposition according to a cos2(π/2-θ) law describes well the experimental distribution of the weight of the deposition layer. The second approach relies on the depletion of aluminum in the liquid pool at two separate times of the volatilization process. Both approaches provide values of the Al activity coefficient at T=1, 860 °C in a fairly narrow range [0.044-0.0495], in good agreement with the range reported in the literature. Furthermore numerical simulation of the Al behavior in the liquid pool reveals (in the specific case of electron beam button melting) a weak transport resistance in the surface boundary layer.

  4. Reproducible strain measurement in electronic devices by applying integer multiple to scanning grating in scanning moiré fringe imaging

    Directory of Open Access Journals (Sweden)

    Suhyun Kim

    2014-10-01

    Full Text Available Scanning moiré fringe (SMF imaging by high-angle annular dark field scanning transmission electron microscopy was used to measure the strain field in the channel of a transistor with a CoSi2 source and drain. Nanometer-scale SMFs were formed with a scanning grating size of ds at integer multiples of the Si crystal lattice spacing dl (ds ∼ ndl, n = 2, 3, 4, 5. The moiré fringe formula was modified to establish a method for quantifying strain measurement. We showed that strain fields in a transistor measured by SMF images were reproducible with an accuracy of 0.02%.

  5. Sparse sampling and reconstruction for electron and scanning probe microscope imaging

    Science.gov (United States)

    Anderson, Hyrum; Helms, Jovana; Wheeler, Jason W.; Larson, Kurt W.; Rohrer, Brandon R.

    2015-07-28

    Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

  6. Focusing on Environmental Biofilms With Variable-Pressure Scanning Electron Microscopy

    Science.gov (United States)

    Joubert, L.; Wolfaardt, G. M.; Du Plessis, K.

    2006-12-01

    Since the term biofilm has been coined almost 30 years ago, visualization has formed an integral part of investigations on microbial attachment. Electron microscopic (EM) biofilm studies, however, have been limited by the hydrated extracellular matrix which loses structural integrity with conventional preparative techniques, and under required high-vacuum conditions, resulting in a loss of information on spatial relationships and distribution of biofilm microbes. Recent advances in EM technology enable the application of Variable Pressure Scanning Electron Microscopy (VP SEM) to biofilms, allowing low vacuum and hydrated chamber atmosphere during visualization. Environmental biofilm samples can be viewed in situ, unfixed and fully hydrated, with application of gold-sputter-coating only, to increase image resolution. As the impact of microbial biofilms can be both hazardous and beneficial to man and his environment, recognition of biofilms as a natural form of microbial existence is needed to fully assess the potential role of microbial communities on technology. The integration of multiple techniques to elucidate biofilm processes has become imperative for unraveling complex phenotypic adaptations of this microbial lifestyle. We applied VP SEM as integrative technique with traditional and novel analytical techniques to (1)localize lignocellulosic microbial consortia applied for producing alternative bio-energy sources in the mining wastewater industry, (2) characterize and visualize wetland microbial communities in the treatment of winery wastewater, and (3)determine the impact of recombinant technology on yeast biofilm behavior. Visualization of microbial attachment to a lignocellulose substrate, and degradation of exposed plant tissue, gave insight into fiber degradation and volatile fatty acid production for biological sulphate removal from mining wastewater. Also, the 3D-architecture of complex biofilms developing in constructed wetlands was correlated with

  7. Non-vacuum electron-beam carburizing and surface hardening of mild steel

    Energy Technology Data Exchange (ETDEWEB)

    Bataev, I.A., E-mail: ivanbataev@ngs.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Golkovskii, M.G., E-mail: M.G.Golkovski@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, Lavrentieva Prospect 11, 630090 Novosibirsk (Russian Federation); Losinskaya, A.A., E-mail: anna.losinskaya@mail.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Bataev, A.A., E-mail: bataev@adm.nstu.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Popelyukh, A.I., E-mail: aip13@mail.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Hassel, T., E-mail: hassel@iw.uni-hannover.de [Leibniz University, Welfengarten 1, 30167 Hannover (Germany); Golovin, D.D., E-mail: ddgolovin@yandex.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation)

    2014-12-15

    Highlights: • Steel specimens were carburized by non-vacuum electron-beam cladding. • The depth of the clad layers reached 2.6 mm. • The cladding rate was 1.8 m{sup 2}/h, the quenching rate 12.6 m{sup 2}/h. • The microhardness of the quenched and tempered layers reached 8 GPa. - Abstract: In this paper, we study the structure, microhardness, and tribological properties of surface layers of mild (0.19% C) steel, which was formed by electron-beam cladding with an iron–graphite powder mixture followed by quenching and tempering. A 1.4 MeV electron beam that was extracted into air was used. Cladding of steel with the iron–graphite mixture at a beam current of 24 and 26 mA formed a hypoeutectic cast iron layer (2.19% C) and a hypereutectoid steel (1.57% C) layer, which were 2.0 and 2.6 mm thick, respectively. The microhardness of the surface-quenched and tempered steel and cast iron layers was 7 and 8 GPa, respectively. Electron-beam quenching of the surface layers of hypoeutectic cast iron was accompanied with multiple cracking. During the quenching of the 1.57% C steel layer, crack formation was not observed. In friction tests against fixed and loose abrasive particles, the surface layers of hypereutectoid steel and hypoeutectic cast iron that were produced by electron-beam cladding and quenching had lower wear rates than mild steel after pack carburizing, quenching, and tempering. In the sliding wear tests, the cast iron clad layer, which was subjected to electron-beam quenching and tempering, exhibited the highest wear resistance. Electron-beam treatment can be used to harden local areas of large workpieces. It is reasonable to treat clad layers of high-carbon steel with electron-beam quenching and tempering. To prevent multiple cracking, white cast iron layers should not be quenched.

  8. Observation of the sweating in lipstick by scanning electron microscopy.

    Science.gov (United States)

    Seo, S Y; Lee, I S; Shin, H Y; Choi, K Y; Kang, S H; Ahn, H J

    1999-06-01

    The relationship between the wax matrix in lipstick and sweating has been investigated by observing the change of size and shape of the wax matrix due to sweating by Scanning Electron Microscopy (SEM). For observation by SEM, a lipstick sample was frozen in liquid nitrogen. The oil in the lipstick was then extracted in cold isopropanol (-70 degrees C) for 1-3 days. After the isopropanol was evaporated, the sample was sputtered with gold and examined by SEM. The change of wax matrix underneath the surface from fine, uniform structure to coarse, nonuniform structure resulted from the caking of surrounding wax matrix. The oil underneath the surface migrated to the surface of lipstick with sweating; consequently the wax matrix in that region was rearranged into the coarse matrix. In case of flamed lipstick, sweating was delayed and the wax matrix was much coarser than that of the unflamed one. The larger wax matrix at the surface region was good for including oil. The effect of molding temperature on sweating was also studied. As the molding temperature rose, sweating was greatly reduced and the size of the wax matrix increased. It was found that sweating was influenced by the compatibility of wax and oil. A formula consisting of wax and oil that have good compatibility has a tendency to reduce sweating and increase the size of the wax matrix. When pigments were added to wax and oil, the size of the wax matrix was changed, but in all cases sweating was increased due to the weakening of the binding force between wax and oil. On observing the thick membrane of wax at the surface of lipstick a month after molding it was also found that sweating was influenced by ageing. In conclusion, the structure of the wax matrix at the surface region of lipstick was changed with the process of flaming, molding temperature, compatibility of wax and oil, addition of pigment, and ageing. In most cases, as the size of the wax matrix was increased, sweating was reduced and delayed.

  9. Active vacuum brazing of CNT films to metal substrates for superior electron field emission performance.

    Science.gov (United States)

    Longtin, Rémi; Ramon Sanchez-Valencia, Juan; Shorubalko, Ivan; Furrer, Roman; Hack, Erwin; Elsener, Hansrudolf; Gröning, Oliver; Greenwood, Paul; Rupesinghe, Nalin; Teo, Kenneth; Leinenbach, Christian; Gröning, Pierangelo

    2015-02-01

    The joining of macroscopic films of vertically aligned multiwalled carbon nanotubes (CNTs) to titanium substrates is demonstrated by active vacuum brazing at 820 °C with a Ag-Cu-Ti alloy and at 880 °C with a Cu-Sn-Ti-Zr alloy. The brazing methodology was elaborated in order to enable the production of highly electrically and thermally conductive CNT/metal substrate contacts. The interfacial electrical resistances of the joints were measured to be as low as 0.35 Ω. The improved interfacial transport properties in the brazed films lead to superior electron field-emission properties when compared to the as-grown films. An emission current of 150 μA was drawn from the brazed nanotubes at an applied electric field of 0.6 V μm-1. The improvement in electron field-emission is mainly attributed to the reduction of the contact resistance between the nanotubes and the substrate. The joints have high re-melting temperatures up to the solidus temperatures of the alloys; far greater than what is achievable with standard solders, thus expanding the application potential of CNT films to high-current and high-power applications where substantial frictional or resistive heating is expected.

  10. Development of a surface conductivity measurement system for ultrahigh vacuum transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Minoda, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012 (Japan); Hatano, K.; Yazawa, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan)

    2009-11-15

    The surface conductivity measurement system using a micro-four-point probe (M4PP) had been developed for the ultrahigh vacuum transmission electron microscope (UHV-TEM). Since the current distribution in the sample crystals during the current voltage measurement by the M4PP is localized within the depth of several micrometers from the surface, the system is sensitive to the surface conductivity, which is related with the surface superstructure. It was installed in the main chamber of the TEM and the surface conductivity can be measured in situ. The surface structures were observed by reflection electron microscopy and diffraction (REM-RHEED). REM-RHEED enables us to observe the surface superstructures and their structure defects such as surface atomic steps and domain boundaries of the surface superstructure. Thus the effects of the defects on the surface conductivity can be investigated. In the present paper we present the surface conductivity measurement system and its application to the Si(111)-{radical}(3)x{radical}(3)-Ag surface prepared on the Si(111) vicinal surfaces. The result clearly showed that the surface conductivity was affected by step configuration.

  11. Vacuum ultraviolet spectroscopy of the lowest-lying electronic state in subcritical and supercritical water.

    Science.gov (United States)

    Marin, Timothy W; Janik, Ireneusz; Bartels, David M; Chipman, Daniel M

    2017-05-17

    The nature and extent of hydrogen bonding in water has been scrutinized for decades, including how it manifests in optical properties. Here we report vacuum ultraviolet absorption spectra for the lowest-lying electronic state of subcritical and supercritical water. For subcritical water, the spectrum redshifts considerably with increasing temperature, demonstrating the gradual breakdown of the hydrogen-bond network. Tuning the density at 381 °C gives insight into the extent of hydrogen bonding in supercritical water. The known gas-phase spectrum, including its vibronic structure, is duplicated in the low-density limit. With increasing density, the spectrum blueshifts and the vibronic structure is quenched as the water monomer becomes electronically perturbed. Fits to the supercritical water spectra demonstrate consistency with dimer/trimer fractions calculated from the water virial equation of state and equilibrium constants. Using the known water dimer interaction potential, we estimate the critical distance between molecules (ca. 4.5 Å) needed to explain the vibronic structure quenching.

  12. Overcoming Challenges in Kinetic Modeling of Magnetized Plasmas and Vacuum Electronic Devices

    Science.gov (United States)

    Omelchenko, Yuri; Na, Dong-Yeop; Teixeira, Fernando

    2017-10-01

    We transform the state-of-the art of plasma modeling by taking advantage of novel computational techniques for fast and robust integration of multiscale hybrid (full particle ions, fluid electrons, no displacement current) and full-PIC models. These models are implemented in 3D HYPERS and axisymmetric full-PIC CONPIC codes. HYPERS is a massively parallel, asynchronous code. The HYPERS solver does not step fields and particles synchronously in time but instead executes local variable updates (events) at their self-adaptive rates while preserving fundamental conservation laws. The charge-conserving CONPIC code has a matrix-free explicit finite-element (FE) solver based on a sparse-approximate inverse (SPAI) algorithm. This explicit solver approximates the inverse FE system matrix (``mass'' matrix) using successive sparsity pattern orders of the original matrix. It does not reduce the set of Maxwell's equations to a vector-wave (curl-curl) equation of second order but instead utilizes the standard coupled first-order Maxwell's system. We discuss the ability of our codes to accurately and efficiently account for multiscale physical phenomena in 3D magnetized space and laboratory plasmas and axisymmetric vacuum electronic devices.

  13. Vacuum Technology

    Energy Technology Data Exchange (ETDEWEB)

    Biltoft, P J

    2004-10-15

    The environmental condition called vacuum is created any time the pressure of a gas is reduced compared to atmospheric pressure. On earth we typically create a vacuum by connecting a pump capable of moving gas to a relatively leak free vessel. Through operation of the gas pump the number of gas molecules per unit volume is decreased within the vessel. As soon as one creates a vacuum natural forces (in this case entropy) work to restore equilibrium pressure; the practical effect of this is that gas molecules attempt to enter the evacuated space by any means possible. It is useful to think of vacuum in terms of a gas at a pressure below atmospheric pressure. In even the best vacuum vessels ever created there are approximately 3,500,000 molecules of gas per cubic meter of volume remaining inside the vessel. The lowest pressure environment known is in interstellar space where there are approximately four molecules of gas per cubic meter. Researchers are currently developing vacuum technology components (pumps, gauges, valves, etc.) using micro electro mechanical systems (MEMS) technology. Miniature vacuum components and systems will open the possibility for significant savings in energy cost and will open the doors to advances in electronics, manufacturing and semiconductor fabrication. In conclusion, an understanding of the basic principles of vacuum technology as presented in this summary is essential for the successful execution of all projects that involve vacuum technology. Using the principles described above, a practitioner of vacuum technology can design a vacuum system that will achieve the project requirements.

  14. U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakaran, Ramprashad [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rhodes, Mark A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Schemer-Kohrn, Alan L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Guzman, Anthony D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-03-30

    The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

  15. U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakaran, Ramprashad [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rhodes, Mark A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Schemer-Kohrn, Alan L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Guzman, Anthony D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-01

    The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

  16. Metal particles in a ceramic matrix--scanning electron microscopy and transmission electron microscopy characterization.

    Science.gov (United States)

    Konopka, K

    2006-09-01

    This paper is concerned with ceramic matrix (Al(2)O(3)) composites with introduced metal particles (Ni, Fe). The composites were obtained via sintering of powders under very high pressure (2.5 GPa). Scanning electron microscopy and transmission electron microscopy were chosen as the tools for the identification and description of the shape, size and distribution of the metal particles. The Al(2)O(3)-Ni composite contained agglomerates of the Ni particles surrounded by ceramic grains and nanometre-size Ni particles located inside the ceramic grains and at the ceramic grain boundaries. In the Al(2)O(3)-Fe composite, the Fe particles were mostly surrounded by ceramic grains. Moreover, holes left by the Fe particles were found. The high pressure used in the fabrication of the composites changed the shape of the metal and ceramic powder grains via plastic deformation.

  17. Annular electron energy-loss spectroscopy in the scanning transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Ruben, Gary [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Bosman, Michel [Institute of Materials Research and Engineering, A-STAR (Agency for Science, Technology and Research), 3 Research Link, Singapore 117602 (Singapore); D' Alfonso, Adrian J. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Okunishi, Eiji; Kondo, Yukihito [JEOL Ltd., 1-2, Musashino 3-chome Akishima, Tokyo 196-8558 (Japan); Allen, Leslie J., E-mail: lja@unimelb.edu.au [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia)

    2011-11-15

    We study atomic-resolution annular electron energy-loss spectroscopy (AEELS) in scanning transmission electron microscopy (STEM) imaging with experiments and numerical simulations. In this technique the central part of the bright field disk is blocked by a beam stop, forming an annular entry aperture to the spectrometer. The EELS signal thus arises only from electrons scattered inelastically to angles defined by the aperture. It will be shown that this method is more robust than conventional EELS imaging to variations in specimen thickness and can also provide higher spatial resolution. This raises the possibility of lattice resolution imaging of lighter elements or ionization edges previously considered unsuitable for EELS imaging. -- Highlights: Black-Right-Pointing-Pointer We study annular electron energy-loss spectroscopy (AEELS) in STEM. Black-Right-Pointing-Pointer This is more robust to changes in specimen thickness than conventional EELS. Black-Right-Pointing-Pointer AEELS provides higher spatial resolution than conventional EELS. Black-Right-Pointing-Pointer This raises the possibility of lattice resolution imaging of lighter elements.

  18. EDITORIAL: 17th International Summer School on Vacuum, Electron, and Ion Technologies (VEIT 2011)

    Science.gov (United States)

    van de Sanden, M. C. M.; Dimitrova, Miglena; Ghelev, Chavdar

    2012-03-01

    The International Summer School on Vacuum, Electron and Ion Technologies (VEIT) has been organized biennially since 1977, when the VEIT Summer School series was launched by the Institute of Electronics, Bulgarian Academy of Sciences. The aim was to act as a forum for the exchange and dissemination of knowledge and ideas on the latest developments in electron-, ion- and plasma-assisted technologies. The organizers of the 2011 edition of the event were the Institute of Electronics, Bulgarian Academy of Sciences, Sofia, Bulgaria and the Department of Applied Physics, Eindhoven University of Technology, Eindhoven, The Netherlands. Whilst the school initially provided a meeting place for researchers mainly from Eastern and Central European countries, its importance has grown issue by issue. The school is now a major scientific event and a meeting place for young scientists from Eastern and Western Europe involved in research and development associated with high-tech industries. Many former school participants have gone on to become leading scientists in research establishments and companies throughout the world. Leading international companies, such as High Voltage Engineering, Balzers, Varian, and Hauzer have used the VEIT forum to present their products through oral presentations, poster contributions and exhibits. The School Proceedings have been published in special issues of the international journals Vacuum, Plasma Processes and Polymers and Journal of Physics: Conference Series. The Seventeenth edition of VEIT was held in the Black Sea resort of Sunny Beach, Bulgaria on 19-23 September 2011. It was attended by 96 participants from 18 countries: Belgium, Brazil, Bulgaria, Czech Republic, Denmark, France, Germany, Greece, The Netherlands, Romania, Russia, Serbia, Sweden, Switzerland, Turkey, Ukraine, UK and USA. Following the tradition of publishing the VEIT Proceedings, a selection of papers presented at the event is published in this special issue of Journal of

  19. Electronically Steerable Antennas with Panoramic Scan Field of View Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Electronically steerable antennas are key to effective radio transmission at millimeter-wave frequencies. To enable communication with rovers, robots, EVA...

  20. The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yuanyuan [Physical & Computational Science Directorate, Pacific Northwest National Laboratory, Richland WA 99352 USA; Browning, Nigel D. [Physical & Computational Science Directorate, Pacific Northwest National Laboratory, Richland WA 99352 USA; Department of Materials Science and Engineering, University of Washington, Seattle WA 98195 USA

    2017-08-02

    As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

  1. Analysis of Bubble Flow in the Deep-Penetration Molten Pool of Vacuum Electron Beam Welding

    Science.gov (United States)

    Luo, Yi; Wan, Rui; Zhu, Yang; Xie, Xiaojian

    2015-03-01

    Based on the vacuum electron beam welding with deep-penetration process, the convection phenomenon of the bubble flow in partially penetrated and fully penetrated molten pool of AZ91D magnesium alloy was simulated under the unsteady-state conditions. At the same time, the distributions of the cavity-type defects in deep-penetration weld were studied. The results showed that the cavity-type defects are more prone to distribute at the bottom of the weld and accumulate along the axis of the weld for the partially penetrated weld seam; there is a high incidence of cavity-type defects in the middle of the weld for the fully penetrated weld seam. As a smooth escape channel for the gas phase is formed in the fully penetrated molten pool, the possibility of gas escaping is much higher than that in the partially penetrated molten pool. A high liquid convection velocity is more conducive to the escape of the gas in molten pool. The liquid convection velocity in the fully penetrated molten pool is higher than that in the partially penetrated molten pool. So, the final gas fraction in the fully penetrated molten pool is low. Therefore, the appearance of cavity-type defects in the fully penetrated weld seam is less than that in the partially penetrated weld seam.

  2. Control of the Polarization of a Vacuum-Ultraviolet, High-Gain, Free-Electron Laser

    Directory of Open Access Journals (Sweden)

    Enrico Allaria

    2014-12-01

    Full Text Available The two single-pass, externally seeded free-electron lasers (FELs of the FERMI user facility are designed around Apple-II-type undulators that can operate at arbitrary polarization in the vacuum ultraviolet-to-soft x-ray spectral range. Furthermore, within each FEL tuning range, any output wavelength and polarization can be set in less than a minute of routine operations. We report the first demonstration of the full output polarization capabilities of FERMI FEL-1 in a campaign of experiments where the wavelength and nominal polarization are set to a series of representative values, and the polarization of the emitted intense pulses is thoroughly characterized by three independent instruments and methods, expressly developed for the task. The measured radiation polarization is consistently >90% and is not significantly spoiled by the transport optics; differing, relative transport losses for horizontal and vertical polarization become more prominent at longer wavelengths and lead to a non-negligible ellipticity for an originally circularly polarized state. The results from the different polarimeter setups validate each other, allow a cross-calibration of the instruments, and constitute a benchmark for user experiments.

  3. PREFACE: 16th International Summer School on Vacuum, Electron, and Ion Technologies (VEIT 2009)

    Science.gov (United States)

    Möller, Wolfhard; Guerassimov, Nikolay; Ghelev, Chavdar

    2010-04-01

    The International Summer School on Vacuum, Electron and Ion Technologies (VEIT) has been organized biennially since 1977 when the series of VEIT Schools was launched by the Institute of Electronics, Bulgarian Academy of Sciences with the aim to act as a forum for interchange and dissemination of knowledge and ideas on the latest developments in electron-, ion-, and plasma-assisted technologies. Beginning from 2001, the school has been jointly organized with the Institute of Ion Beam Physics and Materials Research, Forschungszentrum Dresden-Rossendorf, Germany. Whereas, the school initially provided a meeting place for researchers mainly from Eastern and Central European countries, its importance grew issue by issue. The school is now a major scientific event and a meeting place for young scientists from Eastern and Western Europe involved in research and development associated with high-tech industries. Many former school participants have gone on to become leading scientists in research establishments and companies throughout the world. Leading international companies, such as High Voltage Engineering, Balzers, Varian, and Hauzer have used the VEIT forum to present their products through oral presentations, poster contributions or exhibits. The School Proceedings have been published in special issues of the international journals Vacuum, Plasma Processes and Polymers, Journal of Physics: Conference Series. The Sixteenth VEIT school was held in the Black Sea resort Sunny Beach, Bulgaria on 28 September to 2 October 2009. It was attended by close to 110 participants from 13 countries: Belgium, Bulgaria, Czech Republic, France, Germany, The Netherlands, Romania, Slovak Republic, Spain, Sweden, Ukraine, UK and USA. Following the tradition of publishing the VEIT Proceedings, a selection of papers presented at the event is published in this volume of Journal of Physics: Conference Series, under the originality and quality criteria of acceptance by the journal, including

  4. Experimental setup for energy-filtered scanning confocal electron microscopy (EFSCEM) in a double aberration-corrected transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Wang, P; Behan, G; Kirkland, A I; Nellist, P D, E-mail: peng.wang@materials.ox.ac.u [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom)

    2010-07-01

    Scanning confocal electron microscopy (SCEM) is a new imaging mode in electron microscopy. Spherical aberration corrected electron microscope instruments fitted with two aberration correctors can be used in this mode which provides improved depth resolution and selectivity compared to optical sectioning in a conventional scanning transmission geometry. In this article, we consider a confocal optical configuration for SCEM using inelastically scattered electrons. We lay out the necessary steps for achieving this new operational mode in a double aberration-corrected instrument with uncorrected chromatic aberration and present preliminary experimental results in such mode.

  5. Imaging systems in the Delft Multi-Beam Scanning Electron Microscope 1

    NARCIS (Netherlands)

    Ren, Y.

    2017-01-01

    The goal of this Ph.D. research is to develop imaging systems for the multiple beam scanning electron microscope (MBSEM) built in Delft University of Technology. This thesis includes two imaging systems, transmission electron (TE) imaging system, and secondary electron (SE) imaging system. The major

  6. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    Directory of Open Access Journals (Sweden)

    Xin-Bing Cheng

    2011-04-01

    Full Text Available The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the flatness of the output voltage is discussed before and after adding an insulation plate when a water load is used. It is found that the electron emission at the edges of the cathode holder is the main reason to cause the change of the flatness. Last, a piece of polyester film is used as a target to further show the electron emission of the cathode holder. This analysis shows that decreasing the electron emission of the cathode holder in such a pulse power modulator could be a good way to improve the quality of the output voltage.

  7. Vacuum-thermal-evaporation: the route for roll-to-roll production of large-area organic electronic circuits

    Science.gov (United States)

    Taylor, D. M.

    2015-05-01

    Surprisingly little consideration is apparently being given to vacuum-evaporation as the route for the roll-to-roll (R2R) production of large-area organic electronic circuits. While considerable progress has been made by combining silicon lithographic approaches with solution processing, it is not obvious that these will be compatible with a low-cost, high-speed R2R process. Most efforts at achieving this ambition are directed at conventional solution printing approaches such as inkjet and gravure. This is surprising considering that vacuum-evaporation of organic semiconductors (OSCs) is already used commercially in the production of organic light emitting diode displays. Beginning from a discussion of the materials and geometrical parameters determining transistor performance and drawing on results from numerous publications, this review makes a case for vacuum-evaporation as an enabler of R2R organic circuit production. The potential of the vacuum route is benchmarked against solution approaches and found to be highly competitive. For example, evaporated small molecules tend to have higher mobility than printed OSCs. High resolution metal patterning on plastic films is already a low-cost commercial process for high-volume packaging applications. Similarly, solvent-free flash-evaporation and polymerization of thin films on plastic substrates is also a high-volume commercial process and has been shown capable of producing robust gate dielectrics. Reports of basic logic circuit elements produced in a vacuum R2R environment are reviewed and shown to be superior to all-solution printing approaches. Finally, the main issues that need to be resolved in order to fully develop the vacuum route to R2R circuit production are highlighted.

  8. Evaluation of the bleached human enamel by Scanning Electron Microscopy

    DEFF Research Database (Denmark)

    Miranda, Carolina Baptista; Pagani, Clovis; Benetti, Ana Raquel

    2005-01-01

    Since bleaching has become a popular procedure, the effect of peroxides on dental hard tissues is of great interest in research. Purpose: The aim of this in vitro study was to perform a qualitative analysis of the human enamel after the application of in-office bleaching agents, using Scanning...... characteristic of an erosive process that took place on human enamel. Depression areas, including the formation of craters, and exposure of enamel rods could also be detected. Conclusion: Bleaching effects on enamel morphology were randomly distributed throughout enamel surface and various degrees of enamel...

  9. Method and apparatus for a high-resolution three dimensional confocal scanning transmission electron microscope

    Science.gov (United States)

    de Jonge, Niels [Oak Ridge, TN

    2010-08-17

    A confocal scanning transmission electron microscope which includes an electron illumination device providing an incident electron beam propagating in a direction defining a propagation axis, and a precision specimen scanning stage positioned along the propagation axis and movable in at least one direction transverse to the propagation axis. The precision specimen scanning stage is configured for positioning a specimen relative to the incident electron beam. A projector lens receives a transmitted electron beam transmitted through at least part of the specimen and focuses this transmitted beam onto an image plane, where the transmitted beam results from the specimen being illuminated by the incident electron beam. A detection system is placed approximately in the image plane.

  10. 3D correlative light and electron microscopy of cultured cells using serial blockface scanning electron microscopy

    Science.gov (United States)

    Lerner, Thomas R.; Burden, Jemima J.; Nkwe, David O.; Pelchen-Matthews, Annegret; Domart, Marie-Charlotte; Durgan, Joanne; Weston, Anne; Jones, Martin L.; Peddie, Christopher J.; Carzaniga, Raffaella; Florey, Oliver; Marsh, Mark; Gutierrez, Maximiliano G.

    2017-01-01

    ABSTRACT The processes of life take place in multiple dimensions, but imaging these processes in even three dimensions is challenging. Here, we describe a workflow for 3D correlative light and electron microscopy (CLEM) of cell monolayers using fluorescence microscopy to identify and follow biological events, combined with serial blockface scanning electron microscopy to analyse the underlying ultrastructure. The workflow encompasses all steps from cell culture to sample processing, imaging strategy, and 3D image processing and analysis. We demonstrate successful application of the workflow to three studies, each aiming to better understand complex and dynamic biological processes, including bacterial and viral infections of cultured cells and formation of entotic cell-in-cell structures commonly observed in tumours. Our workflow revealed new insight into the replicative niche of Mycobacterium tuberculosis in primary human lymphatic endothelial cells, HIV-1 in human monocyte-derived macrophages, and the composition of the entotic vacuole. The broad application of this 3D CLEM technique will make it a useful addition to the correlative imaging toolbox for biomedical research. PMID:27445312

  11. Design of Pixellated CMOS Photon Detector for Secondary Electron Detection in the Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Joon Huang Chuah

    2011-01-01

    Full Text Available This paper presents a novel method of detecting secondary electrons generated in the scanning electron microscope (SEM. The method suggests that the photomultiplier tube (PMT, traditionally used in the Everhart-Thornley (ET detector, is to be replaced with a configurable multipixel solid-state photon detector offering the advantages of smaller dimension, lower supply voltage and power requirements, and potentially cheaper product cost. The design of the proposed detector has been implemented using a standard 0.35 μm CMOS technology with optical enhancement. This microchip comprises main circuit constituents of an array of photodiodes connecting to respective noise-optimised transimpedance amplifiers (TIAs, a selector-combiner (SC circuit, and a postamplifier (PA. The design possesses the capability of detecting photons with low input optical power in the range of 1 nW with 100 μm × 100 μm sized photodiodes and achieves a total amplification of 180 dBΩ at the output.

  12. Depth Sectioning with the Aberration-Corrected Scanning Transmission Electron Microscope

    National Research Council Canada - National Science Library

    Albina Y. Borisevich; Andrew R. Lupini; Stephen J. Pennycook

    2006-01-01

    The ability to correct the aberrations of the probe-forming lens in the scanning transmission electron microscope provides not only a significant improvement in transverse resolution but in addition...

  13. A Low Cost, Electronically Scanned Array (ESA) Antenna Technology for Aviation Hazard Detection and Avoidance Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project will investigate the feasibility of utilizing ThinKom's low cost electronically scanned array (ESA) antenna concepts to enable affordable...

  14. Quantitative detection of gold nanoparticles on individual, unstained cancer cells by Scanning Electron Microscopy

    NARCIS (Netherlands)

    Hartsuiker, Liesbeth; van Es, Peter; Petersen, Wilhelmina; van Leeuwen, Ton; Terstappen, Leonardus Wendelinus Mathias Marie; Otto, Cornelis

    2011-01-01

    Gold nanoparticles are rapidly emerging for use in biomedical applications. Characterization of the interaction and delivery of nanoparticles to cells through microscopy is important. Scanning electron microscopes have the intrinsic resolution to visualize gold nanoparticles on cells. A novel sample

  15. Stochastic Micro-Pattern for Automated Correlative Fluorescence - Scanning Electron Microscopy

    Science.gov (United States)

    Begemann, Isabell; Viplav, Abhiyan; Rasch, Christiane; Galic, Milos

    2015-01-01

    Studies of cellular surface features gain from correlative approaches, where live cell information acquired by fluorescence light microscopy is complemented by ultrastructural information from scanning electron micrographs. Current approaches to spatially align fluorescence images with scanning electron micrographs are technically challenging and often cost or time-intensive. Relying exclusively on open-source software and equipment available in a standard lab, we have developed a method for rapid, software-assisted alignment of fluorescence images with the corresponding scanning electron micrographs via a stochastic gold micro-pattern. Here, we provide detailed instructions for micro-pattern production and image processing, troubleshooting for critical intermediate steps, and examples of membrane ultra-structures aligned with the fluorescence signal of proteins enriched at such sites. Together, the presented method for correlative fluorescence – scanning electron microscopy is versatile, robust and easily integrated into existing workflows, permitting image alignment with accuracy comparable to existing approaches with negligible investment of time or capital. PMID:26647824

  16. An electron beam linear scanning mode for industrial limited-angle nano-computed tomography

    Science.gov (United States)

    Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng

    2018-01-01

    Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.

  17. Interstitial cells of Cajal and Auerbach's plexus. A scanning electron microscopical study of guinea-pig small intestine

    DEFF Research Database (Denmark)

    Jessen, Harry; Thuneberg, Lars

    1991-01-01

    Anatomy, interstitial cells of Cajal, myenteric plexus, small intestine, guinea-pig, scanning electron microscopy......Anatomy, interstitial cells of Cajal, myenteric plexus, small intestine, guinea-pig, scanning electron microscopy...

  18. Scanning Electron Microscopy (SEM) Procedure for HE Powders on a Zeiss Sigma HD VP SEM

    Energy Technology Data Exchange (ETDEWEB)

    Zaka, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-11-15

    This method describes the characterization of inert and HE materials by the Zeiss Sigma HD VP field emission Scanning Electron Microscope (SEM). The SEM uses an accelerated electron beam to generate high-magnification images of explosives and other materials. It is fitted with five detectors (SE, Inlens, STEM, VPSE, HDBSD) to enable imaging of the sample via different secondary electron signatures, angles, and energies. In addition to imaging through electron detection, the microscope is also fitted with two Oxford Instrument Energy Dispersive Spectrometer (EDS) 80 mm detectors to generate elemental constituent spectra and two-dimensional maps of the material being scanned.

  19. Big Data Analytics for Scanning Transmission Electron Microscopy Ptychography

    OpenAIRE

    Jesse, S.; Chi, M.; Belianinov, A.; Beekman, C.; Kalinin, S. V.; Borisevich, A. Y.; Lupini, A. R.

    2016-01-01

    Electron microscopy is undergoing a transition; from the model of producing only a few micrographs, through the current state where many images and spectra can be digitally recorded, to a new mode where very large volumes of data (movies, ptychographic and multi-dimensional series) can be rapidly obtained. Here, we discuss the application of so-called ?big-data? methods to high dimensional microscopy data, using unsupervised multivariate statistical techniques, in order to explore salient ima...

  20. SPEAKING IN LIGHT - Jupiter radio signals as deflections of light-emitting electron beams in a vacuum chamber

    Science.gov (United States)

    Petrovic, K.

    2015-10-01

    Light emitting electron beam generated in a vacuum chamber is used as a medium for visualizing Jupiter's electromagnetic radiation. Dual dipole array antenna is receiving HF radio signals that are next amplified to radiate a strong electromagnetic field capable of influencing the propagation of electron beam in plasma. Installation aims to provide a platform for observing the characteristics of light emitting beam in 3D, as opposed to the experiments with cathode ray tubes in 2-dimensional television screens. Gas giant 'speaking' to us by radio waves bends the light in the tube, allowing us to see and hear the messages of Jupiter - God of light and sky.

  1. Scanning Transmission Electron microscope Studies of Deep-Frozen Unfixed Muscle Correlated with Spatial Localization of Intracellular Elements by Fluorescent X-Ray Analysis

    Science.gov (United States)

    Bacaner, Marvin; Broadhurst, John; Hutchinson, Thomas; Lilley, John

    1973-01-01

    Thin sections of deep-frozen unfixed muscle were studied in a scanning electron microscope modified for transmission imaging and equipped with a “cryostage” for vacuum compatibility of hydrated tissue. With an energy-dispersive x-ray analysis system, intracellular atomic species in the scan beam path were identified by their fluorescent x-rays and spatially localized in correlation with the electron optical image of the microstructure. Marked differences are noted between the ultrastructure of deep-frozen hydrated muscle and that of fixed dehydrated muscle. In frozen muscle, myofibrils appear to be composed of previously undescribed longitudinal structures between 400-1000 Å wide (“macromyofilaments”). The usual myofilaments, mitochondria, and sarcoplasmic reticulum were not seen unless the tissue was “fixed” before examination. Fluorescent x-ray analysis of the spatial location of constituent elements clearly identified all elements heavier than Na. Intracellular Cl was relatively higher than expected. Images PMID:4587251

  2. Scanning Probe Evaluation of Electronic, Mechanical and Structural Material Properties

    Science.gov (United States)

    Virwani, Kumar

    2011-03-01

    We present atomic force microscopy (AFM) studies of a range of properties from three different classes of materials: mixed ionic electronic conductors, low-k dielectrics, and polymer-coated magnetic nanoparticles. (1) Mixed ionic electronic conductors are being investigated as novel diodes to drive phase-change memory elements. Their current-voltage characteristics are measured with direct-current and pulsed-mode conductive AFM (C-AFM). The challenges to reliability of the C-AFM method include the electrical integrity of the probe, the sample and the contacts, and the minimization of path capacitance. The role of C-AFM in the optimization of these electro-active materials will be presented. (2) Low dielectric constant (low-k) materials are used in microprocessors as interlayer insulators, a role directly affected by their mechanical performance. The mechanical properties of nanoporous silicate low-k thin films are investigated in a comparative study of nanomechanics measured by AFM and by traditional nanoindentation. Both methods are still undergoing refinement as reliable analytical tools for determining nanomechanical properties. We will focus on AFM, the faster of the two methods, and its developmental challenges of probe shape, cantilever force constant, machine compliance and calibration standards. (3) Magnetic nanoparticles are being explored for their use in patterned media for magnetic storage. Current methods for visualizing the core-shell structure of polymer-coated magnetic nanoparticles include dye-staining the polymer shell to provide contrast in transmission electron microscopy. AFM-based fast force-volume measurements provide direct visualization of the hard metal oxide core within the soft polymer shell based on structural property differences. In particular, the monitoring of adhesion and deformation between the AFM tip and the nanoparticle, particle-by-particle, provides a reliable qualitative tool to visualize core-shell contrast without the use

  3. Big Data Analytics for Scanning Transmission Electron Microscopy Ptychography

    Science.gov (United States)

    Jesse, S.; Chi, M.; Belianinov, A.; Beekman, C.; Kalinin, S. V.; Borisevich, A. Y.; Lupini, A. R.

    2016-05-01

    Electron microscopy is undergoing a transition; from the model of producing only a few micrographs, through the current state where many images and spectra can be digitally recorded, to a new mode where very large volumes of data (movies, ptychographic and multi-dimensional series) can be rapidly obtained. Here, we discuss the application of so-called “big-data” methods to high dimensional microscopy data, using unsupervised multivariate statistical techniques, in order to explore salient image features in a specific example of BiFeO3 domains. Remarkably, k-means clustering reveals domain differentiation despite the fact that the algorithm is purely statistical in nature and does not require any prior information regarding the material, any coexisting phases, or any differentiating structures. While this is a somewhat trivial case, this example signifies the extraction of useful physical and structural information without any prior bias regarding the sample or the instrumental modality. Further interpretation of these types of results may still require human intervention. However, the open nature of this algorithm and its wide availability, enable broad collaborations and exploratory work necessary to enable efficient data analysis in electron microscopy.

  4. Big Data Analytics for Scanning Transmission Electron Microscopy Ptychography.

    Science.gov (United States)

    Jesse, S; Chi, M; Belianinov, A; Beekman, C; Kalinin, S V; Borisevich, A Y; Lupini, A R

    2016-05-23

    Electron microscopy is undergoing a transition; from the model of producing only a few micrographs, through the current state where many images and spectra can be digitally recorded, to a new mode where very large volumes of data (movies, ptychographic and multi-dimensional series) can be rapidly obtained. Here, we discuss the application of so-called "big-data" methods to high dimensional microscopy data, using unsupervised multivariate statistical techniques, in order to explore salient image features in a specific example of BiFeO3 domains. Remarkably, k-means clustering reveals domain differentiation despite the fact that the algorithm is purely statistical in nature and does not require any prior information regarding the material, any coexisting phases, or any differentiating structures. While this is a somewhat trivial case, this example signifies the extraction of useful physical and structural information without any prior bias regarding the sample or the instrumental modality. Further interpretation of these types of results may still require human intervention. However, the open nature of this algorithm and its wide availability, enable broad collaborations and exploratory work necessary to enable efficient data analysis in electron microscopy.

  5. Field-emission scanning electron microscopy of the internal cellular organization of fungi

    NARCIS (Netherlands)

    Muller, W.H.; Aelst, van A.C.; Humbel, B.M.; Krift, van der T.P.; Boekhout, T.

    2000-01-01

    Internal viewing of the cellular organization of hyphae by scanning electron microscopy is an alternative to observing sectioned fungal material with a transmission electron microscope. To study cytoplasmic organelles in the hyphal cells of fungi by SEM, colonies were chemically fixed with

  6. Scanning Electron Microscopy (SEM) Procedure for HE Powders on a LEO 438VP System

    Energy Technology Data Exchange (ETDEWEB)

    Zaka, Fowzia [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Energetic Materials Center

    2016-03-08

    This method describes the characterization of HE powders by Scanning Electron Microscopy (SEM). HE particles are dispersed onto an aluminum standard SEM specimen mount. Electron micrographs are collected at various magnifications (150 to 10,000 X) depending on HE particle size.

  7. Scanning Electron Microscopy (SEM) Procedure for HE Powders on a LEO 438VP System

    Energy Technology Data Exchange (ETDEWEB)

    Zaka, Fowzia [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Energetic Materials Center

    2016-03-21

    This method describes the characterization of HE powders by Scanning Electron Microscopy (SEM). HE particles are dispersed onto an aluminum standard SEM specimen mount. Electron micrographs are collected at various magnifications (150 to 10,000 X) depending on HE particle size.

  8. Structural examination of lithium niobate ferroelectric crystals by combining scanning electron microscopy and atomic force microscopy

    Science.gov (United States)

    Efremova, P. V.; Ped'ko, B. B.; Kuznecova, Yu. V.

    2016-02-01

    The structure of lithium niobate single crystals is studied by a complex technique that combines scanning electron microscopy and atomic force microscopy. By implementing the piezoresponse force method on an atomic force microscope, the domain structure of lithium niobate crystals, which was not revealed without electron beam irradiation, is visualized

  9. PREFACE: Fifteenth International Summer School on Vacuum, Electron and Ion Technologies (VEIT 2007)

    Science.gov (United States)

    Guerassimov, Nikolay; Möller, Wolfhard; Ghelev, Chavdar

    2008-03-01

    The International Summer School on Vacuum, Electron and Ion Technologies (VEIT) has been organized biannually since 1977. It is a forum for the interchange and dissemination of knowledge and ideas on the latest developments in electron-, ion-, and plasma-assisted technologies. The organizers of the event (since 2001) have been the Institute of Electronics, Bulgarian Academy of Sciences, Sofia, Bulgaria, the Institute of Ion Beam Physics and Materials Research, Forschungszentrum Dresden-Rossendorf, Dresden, Germany, and the Evrika Foundation, Sofia, Bulgaria. The fifteenth meeting of VEIT was held in the Black Sea resort of Sozopol, Bulgaria from 17-21 September 2007 and was attended by around 120 participants from 17 countries: Australia, Belgium, Bulgaria, Canada, Czech Republic, Germany, Hungary, Italy, The Netherlands, Poland, Pakistan, Romania, Sweden, Switzerland, Ukraine, UK and USA. Following the tradition of publishing the VEIT Proceedings, a selection of papers presented at the event is published in this volume of Journal of Physics: Conference Series, all peer reviewed to meet the originality and quality criteria of the journal. The school consisted of 11 oral and 3 poster sessions. There were 17 invited talks of general interest and 12 progress reports were presented orally. In total 86 contributed papers were presented during the three poster sessions. There were several scientific highlights covering the fundamentals of gas discharges and interaction of fast particles with solids, a wide range of conventional and novel applications such as for hard coatings and optical/protective layers, nanosized structures produced by evaporation, sputtering or external irradiation. Recent achievements in the modification of materials using charged particles or laser beams, thin layers deposition, properties, and characterization and novel materials, techniques, devices were highlighted. Despite the busy scientific program, the atmosphere was relaxed and informal

  10. Electron Cloud Measurements of Coated and Uncoated Vacuum Chambers in the CERN SPS by Means of the Microwave Transmission Method

    CERN Document Server

    Federmann, S; Mahner, E; Costa Pinto, P; Taborelli, M; Salvant, B; Seebacher, D; Yin Vallgren, C

    2010-01-01

    Electron cloud is a limitation to increasing the beam current in the CERN SPS in the frame of an intensity upgrade of the LHC complex. Coating the vacuum chamber with a thin amorphous carbon layer is expected to reduce the electron cloud build-up. Three SPS MBB magnets have been coated to study the performance of this carbon coating. The microwave transmission method is one possible way to monitor electron cloud and hence to test the effect of the coating. In this paper the evolution of the experimental setup for measurements of the electron cloud using LHC type beams will be described. Due to the low revolution frequency of about 43 kHz serious electromagnetic compatibility problems as well as intermodulation have been found. These effects and their mitigation are described. Finally, we present the measurement results illustrating the possible reduction due to the carbon coating.

  11. Monte Carlo modeling of cavity imaging in pure iron using back-scatter electron scanning microscopy

    Science.gov (United States)

    Yan, Qiang; Gigax, Jonathan; Chen, Di; Garner, F. A.; Shao, Lin

    2016-11-01

    Backscattered electrons (BSE) in a scanning electron microscope (SEM) can produce images of subsurface cavity distributions as a nondestructive characterization technique. Monte Carlo simulations were performed to understand the mechanism of void imaging and to identify key parameters in optimizing void resolution. The modeling explores an iron target of different thicknesses, electron beams of different energies, beam sizes, and scan pitch, evaluated for voids of different sizes and depths below the surface. The results show that the void image contrast is primarily caused by discontinuity of energy spectra of backscattered electrons, due to increased outward path lengths for those electrons which penetrate voids and are backscattered at deeper depths. Size resolution of voids at specific depths, and maximum detection depth of specific voids sizes are derived as a function of electron beam energy. The results are important for image optimization and data extraction.

  12. Customized patterned substrates for highly versatile correlative light-scanning electron microscopy

    Science.gov (United States)

    Benedetti, Lorena; Sogne, Elisa; Rodighiero, Simona; Marchesi, Davide; Milani, Paolo; Francolini, Maura

    2014-01-01

    Correlative light electron microscopy (CLEM) combines the advantages of light and electron microscopy, thus making it possible to follow dynamic events in living cells at nanometre resolution. Various CLEM approaches and devices have been developed, each of which has its own advantages and technical challenges. We here describe our customized patterned glass substrates, which improve the feasibility of correlative fluorescence/confocal and scanning electron microscopy. PMID:25391455

  13. A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

    Science.gov (United States)

    Edmunson, J.; Gaskin, J. A.; Jerman, G. A.; Harvey, R. P.; Doloboff, I. J.; Neidholdt, E. L.

    2016-01-01

    The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

  14. Generation of high charge state metal ion beams by electron cyclotron resonance heating of vacuum arc plasma in cusp trap.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Oks, E M; Vizir, A V; Yushkov, G Yu; Vodopyanov, A V; Izotov, I V; Mansfeld, D A

    2012-02-01

    A method for generating high charge state heavy metal ion beams based on high power microwave heating of vacuum arc plasma confined in a magnetic trap under electron cyclotron resonance conditions has been developed. A feature of the work described here is the use of a cusp magnetic field with inherent "minimum-B" structure as the confinement geometry, as opposed to a simple mirror device as we have reported on previously. The cusp configuration has been successfully used for microwave heating of gas discharge plasma and extraction from the plasma of highly charged, high current, gaseous ion beams. Now we use the trap for heavy metal ion beam generation. Two different approaches were used for injecting the vacuum arc metal plasma into the trap--axial injection from a miniature arc source located on-axis near the microwave window, and radial injection from sources mounted radially at the midplane of the trap. Here, we describe preliminary results of heating vacuum arc plasma in a cusp magnetic trap by pulsed (400 μs) high power (up to 100 kW) microwave radiation at 37.5 GHz for the generation of highly charged heavy metal ion beams.

  15. Fundamental and experimental aspects of diffraction for characterizing dislocations by electron channeling contrast imaging in scanning electron microscope

    OpenAIRE

    Kriaa, H.; Guitton, A.; Maloufi, N.

    2017-01-01

    Nowadays Field Emission Gun-Scanning Electron Microscopes provide detailed crystallographic information with high spatial and angular resolutions, and allow direct observation of crystalline defects, such as dislocations, through an attractive technique called Electron Channeling Contrast Imaging (ECCI). Dislocations play a crucial role in the properties of materials and ECCI has naturally emerged as an adapted tool for characterizing defects in bulk specimen. Nevertheless, fine control of th...

  16. Examination of mycological samples by means of the scanning electron microscope

    Directory of Open Access Journals (Sweden)

    M. Thibaut

    1973-04-01

    Full Text Available Three species of Siphomycetes: Rhizopus arhizus, Rhizopus equinus and Rhizopus nigricans, as well as a Septomycete: Emericella nidulans, have been examined by means of a scanning electron microscope. Among the difjerent Rhizopus, this technique showed differences in the appearance of the sporangia. In Emericella nidulans, scanning microscopy enábled one to ascertain that the "Hull cells" were completely hollow and also demonstrated the ornemented aspect of the ascospores.

  17. Comparative study of image contrast in scanning electron microscope and helium ion microscope.

    Science.gov (United States)

    O'Connell, R; Chen, Y; Zhang, H; Zhou, Y; Fox, D; Maguire, P; Wang, J J; Rodenburg, C

    2017-12-01

    Images of Ga+ -implanted amorphous silicon layers in a 110 n-type silicon substrate have been collected by a range of detectors in a scanning electron microscope and a helium ion microscope. The effects of the implantation dose and imaging parameters (beam energy, dwell time, etc.) on the image contrast were investigated. We demonstrate a similar relationship for both the helium ion microscope Everhart-Thornley and scanning electron microscope Inlens detectors between the contrast of the images and the Ga+ density and imaging parameters. These results also show that dynamic charging effects have a significant impact on the quantification of the helium ion microscope and scanning electron microscope contrast. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  18. X-ray diffraction and scanning electron microscopy of galvannealed coatings on steel.

    Science.gov (United States)

    Schmid, P; Uran, K; Macherey, F; Ebert, M; Ullrich, H-J; Sommer, D; Friedel, F

    2009-04-01

    The formation of Fe-Zn intermetallic compounds, as relevant in the commercial product galvannealed steel sheet, was investigated by scanning electron microscopy and different methods of X-ray diffraction. A scanning electron microscope with high resolution was applied to investigate the layers of the galvannealed coating and its topography. Grazing incidence X-ray diffraction (GID) was preferred over conventional Bragg-Brentano geometry for analysing thin crystalline layers because of its lower incidence angle alpha and its lower depth of information. Furthermore, in situ experiments at an environmental scanning electron microscope (ESEM) with an internal heating plate and at an X-ray diffractometer equipped with a high-temperature chamber were carried out. Thus, it was possible to investigate the phase evolution during heat treatment by X-ray diffraction and to display the growth of the zeta crystals in the ESEM.

  19. Optimal imaging techniques in the scanning transmission electron microscope: applications to biological macromolecules.

    Science.gov (United States)

    Ohtsuki, M; Crewe, A V

    1980-01-01

    We show applications of the optimal imaging method to stained biological macromolecules. This optimal imaging method involves the following basic procedures: (i) for any given resolution, which is represented by the electron probe size in the scanning transmission electron microscope, a preferred magnification is used; (ii) the micrographs taken at the condition described above are then spatially filtered by using a low-pass filter (nu < 1/2d, in which d is the space between scan lines) to optically reconstruct the final optimal image. It is found that the micrographs obtained by using the optimal imaging method clearly show an improvement in contrast. Images PMID:6933454

  20. A correlative optical microscopy and scanning electron microscopy approach to locating nanoparticles in brain tumors.

    Science.gov (United States)

    Kempen, Paul J; Kircher, Moritz F; de la Zerda, Adam; Zavaleta, Cristina L; Jokerst, Jesse V; Mellinghoff, Ingo K; Gambhir, Sanjiv S; Sinclair, Robert

    2015-01-01

    The growing use of nanoparticles in biomedical applications, including cancer diagnosis and treatment, demands the capability to exactly locate them within complex biological systems. In this work a correlative optical and scanning electron microscopy technique was developed to locate and observe multi-modal gold core nanoparticle accumulation in brain tumor models. Entire brain sections from mice containing orthotopic brain tumors injected intravenously with nanoparticles were imaged using both optical microscopy to identify the brain tumor, and scanning electron microscopy to identify the individual nanoparticles. Gold-based nanoparticles were readily identified in the scanning electron microscope using backscattered electron imaging as bright spots against a darker background. This information was then correlated to determine the exact location of the nanoparticles within the brain tissue. The nanoparticles were located only in areas that contained tumor cells, and not in the surrounding healthy brain tissue. This correlative technique provides a powerful method to relate the macro- and micro-scale features visible in light microscopy with the nanoscale features resolvable in scanning electron microscopy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Development of electron optical system using annular pupils for scanning transmission electron microscope by focused ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Matsutani, Takaomi, E-mail: matutani@ele.kindai.ac.jp [Kinki University, 3-4-1 Kowakae, Higashiosaka, Osaka 577-8502 (Japan); Yasumoto, Tsuchika; Tanaka, Takeo [Osaka Sangyo University, 3-1-1 Nakagaito, Daito, Osaka 574-8530 (Japan); Kawasaki, Tadahiro; Ichihashi, Mikio [Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Ikuta, Takashi [Osaka Electro-Communication University, 18-8 Hatsu-cho, Neyagawa, Osaka 572-8530 (Japan)

    2012-02-01

    Annular pupils for electron optics were produced using a focused ion beam (FIB), enabling an increase in the depth of focus and allowing for aberration-free imaging and separation of the amplitude and phase images in a scanning transmission electron microscope (STEM). Simulations demonstrate that an increased focal depth is advantageous for three-dimensional tomography in the STEM. For a 200 kV electron beam, the focal depth is increased to approximately 100 nm by using an annular pupil with inner and outer semi-angles of 29 and 30 mrad, respectively. Annular pupils were designed with various outer diameters of 40-120 {mu}m and the inner diameter was designed at 80% of the outer diameter. A taper angle varying from 1 Degree-Sign to 20 Degree-Sign was applied to the slits of the annular pupils to suppress the influence of high-energy electron scattering. The fabricated annular pupils were inspected by scanning ion beam microscopy and scanning electron microscopy. These annular pupils were loaded into a STEM and no charge-up effects were observed in the scintillator projection images recorded by a CCD camera.

  2. Corrections of magnification and focusing in a cathode lens-equipped scanning electron microscope.

    Science.gov (United States)

    Zobacová, J; Zobac, M; Oral, M; Müllerová, I; Frank, L

    2006-01-01

    One of the well-proven and efficient methods of obtaining a very low-energy impact of primary electrons in the scanning electron microscope is to introduce a retarding field element below the pole piece of the objective lens (OL). It is advantageous to use the specimen alone as the negatively biased electrode (i.e., cathode of the cathode lens). The optical power of the cathode lens modifies some of the standard parameters of the image formation such as relation of working distance to OL excitation or magnification to the scanning coils current, the impact angle of primary electrons, and so forth. In computer-controlled electron microscopes these parameters, particularly with regard to focusing and magnification, can be corrected automatically. Derivation of algorithms for such corrections and their experimental verifications are presented in this paper. Furthermore, a more accurate analytical expression for the focal length of an aperture lens is derived.

  3. Imaging and identifying defects in nitride semiconductor thin films using a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Naresh-Kumar, G.; Hourahine, B.; Trager-Cowan, C. [Department of Physics, SUPA, University of Strathclyde, Glasgow (United Kingdom); Vilalta-Clemente, A.; Ruterana, P. [CIMAP UMR 6252 CNRS-ENSICAEN-CEA-UCBN, 6, Caen (France); Gamarra, P.; Lacam, C.; Tordjman, M.; Di Forte-Poisson, M.A. [Thales Research and Technology, III-V Lab, Marcoussis (France); Parbrook, P.J. [Department of Electrical and Electronic Engineering, University of Sheffield (United Kingdom); Day, A.P. [Aunt Daisy Scientific Ltd., Claremont House, High St, Lydney (United Kingdom); England, G. [K. E. Developments Ltd., Cambridge (United Kingdom)

    2012-03-15

    We describe the use of electron channelling contrast imaging (ECCI) - in a field emission scanning electron microscope (SEM) - to reveal and identify defects in nitride semiconductor thin films. In ECCI changes in crystallographic orientation, or changes in lattice constant due to local strain, are revealed by changes in grey scale in an image constructed by monitoring the intensity of backscattered electrons (BSEs) as an electron beam is scanned over a suitably oriented sample. Extremely small orientation changes are detectable, enabling small angle tilt and rotation boundaries and dislocations to be imaged. Images with a resolution of tens of nanometres are obtainable with ECCI. In this paper, we describe the use of ECCI with TEM to determine threading dislocation densities and types in InAlN/GaN heterostructures grown on SiC and sapphire substrates. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Simultaneous Bright-Field and Dark-Field Scanning Transmission Electron Microscopy in Scanning Electron Microscopy: A New Approach for Analyzing Polymer System Morphology

    Science.gov (United States)

    Patel, Binay S.

    Scanning transmission electron microscopy in scanning electron microscopy (STEM-IN-SEM) is a convenient technique for polymer characterization. Utilizing the lower accelerating voltages, larger field of view and, exclusion of post-specimen projection lens in an SEM; STEM-IN-SEM has shown results comparable to transmission electron microscopy (TEM) observation of polymer morphology. Various specimen-holder geometries and detector arrangements have been used for bright field (BF) STEM-IN-SEM imaging. To further the characterization potential of STEM-IN-SEM a new specimen holder has been developed to facilitate simultaneous BF and dark field (DF) STEM-IN-SEM imaging. A new specimen holder and a new microscope configuration were designed for this new imaging technique. BF and DF signals were maximized for optimal STEM-IN-SEM imaging. BF signal intensities were found to be twice as large as DF signal intensities. BF and DF STEM-IN-SEM imaging spatial resolutions are limited to 1.8 nm and approximately 5 nm, respectively. Simultaneous BF & DF STEM-IN-SEM imaging is applicable to both industrial and academic research environments. Examples of commodity and engineering polymer morphology characterization are provided. Results are comparable to TEM observation and may serve as a suitable precursor to STEM characterization of polymer systems. Finally, future developments of various accessories for this technique are discussed.

  5. Probing cytotoxicity of nanoparticles and organic compounds using scanning proton microscopy, scanning electron microscopy and fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tong Yongpeng [Institute of Nuclear Techniques, Shenzhen University, Nanhai Avenue 3688, Shenzhen 518060 (China)], E-mail: yongpengt@yahoo.com.cn; Li Changming [School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637457 (Singapore); Liang Feng [Institute Pasteur of Shanghai, Chinese Academy of Sciences, Shanghai 200025 (China); Chen Jianmin [Shenzhen Municipal Hospital for Chronic Disease Control and Prevention, Guangdong 518020 (China); Zhang Hong; Liu Guoqing; Sun Huibin [Institute of Nuclear Techniques, Shenzhen University, Nanhai Avenue 3688, Shenzhen 518060 (China); Luong, John H.T. [Biotechnology Research Institute, National Research Council Canada, Montreal, Quebec, H4P 2R2 (Canada)

    2008-12-15

    Scanning proton microscopy, scanning electron microscopy (SEM) and fluorescence microscopy have been used to probe the cytotoxicity effect of benzo[a]pyrene (BaP), ethidium bromide (EB) and nanoparticles (ZnO, Al{sub 2}O{sub 3} and TiO{sub 2}) on a T lymphoblastic leukemia Jurkat cell line. The increased calcium ion (from CaCl{sub 2}) in the culture medium stimulated the accumulation of BaP and EB inside the cell, leading to cell death. ZnO, Al{sub 2}O{sub 3} and TiO{sub 2} nanoparticles, however, showed a protective effect against these two organic compounds. Such inorganic nanoparticles complexed with BaP or EB which became less toxic to the cell. Fe{sub 2}O{sub 3} nanoparticles as an insoluble particle model scavenged by macrophage were investigated in rats. They were scavenged out of the lung tissue about 48 h after infection. This result suggest that some insoluble inorganic nanoparticles of PM (particulate matters) showed protective effects on organic toxins induced acute toxic effects as they can be scavenged by macrophage cells. Whereas, some inorganic ions such as calcium ion in PM may help environmental organic toxins to penetrate cell membrane and induce higher toxic effect.

  6. Microscopic techniques bridging between nanoscale and microscale with an atomically sharpened tip - field ion microscopy/scanning probe microscopy/ scanning electron microscopy.

    Science.gov (United States)

    Tomitori, Masahiko; Sasahara, Akira

    2014-11-01

    to extend a model sample prepared for the microscopies towards a microscale sample while keeping the intrinsic properties found by the microscopies.In this study we present our trial of developing microscopic combined instruments among FIM, field emission microscopy (FEM), STM, AFM and scanning electron microscopy (SEM), in which we prepared and characterized the tips for the SPM, and in addition, the sample preparation to take a correlation between nanoscale and microscale properties of functional materials. Recently, we developed a simple sample preparation method of a rutile single crystal TiO2 covered with an epitaxially-grown monolayer of SiO2 by annealing the crystals in a furnace at high temperatures in air; the crystal samples were placed into a quartz container in the furnace [1]. The vapor of SiO evaporated from the quartz container were adsorbed on the crystal while the crystal surfaces being fully oxidized in air. The SiO2-TiO2 composite systems are promising to protect catalytic TiO2 performance; the photo-catalytic activity is kept by coating with hard and stable SiO2 layers and to extend the lifetime of water super-hydrophilicity even in dark, though understanding of their properties is insufficient due to the lack of techniques to fabricate a well-characterized system on a nanoscale to conduct control experiments. The SiO2 overlayers were observed by low energy electron diffraction (LEED) in vacuum and frequency-modulation (FM) AFM in water [1,2], and water contact angles (WCA) were measured [2]. Although the WCA measurement seems a classic characterization, this method possesses a high potential to make a bridge by controlling the environmental conditions. We will discuss the details. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Studying Dynamic Processes of Nano-sized Objects in Liquid using Scanning Transmission Electron Microscopy

    OpenAIRE

    Hermannsd?rfer, Justus; de Jonge, Niels

    2017-01-01

    Samples fully embedded in liquid can be studied at a nanoscale spatial resolution with Scanning Transmission Electron Microscopy (STEM) using a microfluidic chamber assembled in the specimen holder for Transmission Electron Microscopy (TEM) and STEM. The microfluidic system consists of two silicon microchips supporting thin Silicon Nitride (SiN) membrane windows. This article describes the basic steps of sample loading and data acquisition. Most important of all is to ensure that the liquid c...

  8. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy.

    Science.gov (United States)

    Tate, Mark W; Purohit, Prafull; Chamberlain, Darol; Nguyen, Kayla X; Hovden, Robert; Chang, Celesta S; Deb, Pratiti; Turgut, Emrah; Heron, John T; Schlom, Darrell G; Ralph, Daniel C; Fuchs, Gregory D; Shanks, Katherine S; Philipp, Hugh T; Muller, David A; Gruner, Sol M

    2016-02-01

    We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80-200 keV electron beams.

  9. Electron fluctuation induced resonance broadening in nano electromechanical systems: the origin of shear force in vacuum.

    Science.gov (United States)

    Siria, A; Barois, T; Vilella, K; Perisanu, S; Ayari, A; Guillot, D; Purcell, S T; Poncharal, P

    2012-07-11

    This article presents a study of the poorly understood "shear-force" used in an important class of near-field instruments that use mechanical resonance feedback detection. In the case of a metallic probe near a metallic surface in vacuum, we show that in the 10-60 nm range there is no such a thing as a shear-force in the sense of the nonconservative friction force. Fluctuations of the oscillator resonance frequency, likely induced by local charge variations, could account for the reported effects in the literature without introducing a dissipative force.

  10. EVALUATION OF COMPUTER-CONTROLLED SCANNING ELECTRON MICROSCOPY APPLIED TO AN AMBIENT URBAN AEROSOL SAMPLE

    Science.gov (United States)

    Recent interest in monitoring and speciation of particulate matter has led to increased application of scanning electron microscopy (SEM) coupled with energy-dispersive x-ray analysis (EDX) to individual particle analysis. SEM/EDX provides information on the size, shape, co...

  11. Scanning electron microscopy and X-ray spectroscopy applied to mycelial phase of sporothrix schenckii

    Directory of Open Access Journals (Sweden)

    M. Thibaut

    1975-04-01

    Full Text Available Scanning electron microscopy applied to the mycelial phase of Sporothrix schenckii shows a matted mycelium with conidia of a regular pattern. X-Ray microanalysis applied in energy dispersive spectroscopy and also in wavelength dispersive spectroscopy reveals the presence of several elements of Mendeleef's classification.

  12. Morphologic differences observed by scanning electron microscopy according to the reason for pseudophakic IOL explantation

    DEFF Research Database (Denmark)

    Fernandez-Buenaga, Roberto; Alio, Jorge L.; Ramirez, Jose M.

    2015-01-01

    Purpose To compare variations in surface morphology, as studied by scanning electron microscopy (SEM), of explanted intraocular lenses (IOLs) concerning the cause leading to the explantation surgery. Methods In this prospective multicenter study, explanted IOLs were analyzed by SEM and energy-dis...

  13. Scanning electron microscopy with polarization analysis for multilayered chiral spin textures

    NARCIS (Netherlands)

    Lucassen, Juriaan; Kloodt-Twesten, Fabian; Frömter, Robert; Oepen, Hans Peter; Duine, Rembert A.|info:eu-repo/dai/nl/304830127; Swagten, Henk J. M.; Koopmans, Bert; Lavrijsen, Reinoud

    We show that scanning electron microscopy with polarization analysis (SEMPA) that is sensitive to both in-plane magnetization components can be used to image the out-of-plane magnetized multi-domain state in multilayered chiral spin textures. By depositing a thin layer of Fe on top of the multilayer

  14. RGB color coded images in scanning electron microscopy of biological surfaces

    Czech Academy of Sciences Publication Activity Database

    Kofroňová, Olga; Benada, Oldřich

    2017-01-01

    Roč. 61, č. 3 (2017), s. 349-352 ISSN 0001-723X R&D Projects: GA MŠk(CZ) LO1509; GA ČR(CZ) GA16-20229S Institutional support: RVO:61388971 Keywords : Biological surfaces * Color images * Scanning electron microscopy Subject RIV: EE - Microbiology, Virology Impact factor: 0.673, year: 2016

  15. Local electronic structure of Fe(001) surfaces studied by scanning tunneling spectroscopy

    NARCIS (Netherlands)

    Bischoff, M.M.J.; Yamada, T.K.; Fang, C.M.; Groot, R.A. de; Kempen, H. van

    2003-01-01

    Scanning tunneling spectroscopy is used to study the local electronic structure of Fe(001) whiskers. The influence of a voltage dependent background on the apparent peak energies in the dI/dV curves is discussed. A relation between this background and the apparent barrier height is established. The

  16. Surface morphology of the endolymphatic duct in the rat. A scanning electron microscopy study

    DEFF Research Database (Denmark)

    Qvortrup, K; Rostgaard, Jørgen; Bretlau, P

    1995-01-01

    Following intracardiac vascular perfusion fixation of 8 rats with glutaraldehyde in a buffered and oxygenated blood substitute, the vestibular aqueduct and endolymphatic duct were opened by microsurgery of the resulting 16 temporal bones. Optimum preservation of the epithelium for scanning electron...

  17. Fine structure of the endolymphatic duct in the rat. A scanning and transmission electron microscopy study

    DEFF Research Database (Denmark)

    Qvortrup, K; Rostgaard, Jørgen; Bretlau, P

    1995-01-01

    and thiocarbohydrazide followed by a continuous dehydration procedure. Three types of cells were identified with the scanning electron microscope: A polygonal and oblong epithelial cell was observed in the largest number throughout the duct, whereas in the juxta-saccular half of the duct two additional types...

  18. Focused Ion Beam - Scanning Electron Microscopy Applied to Electrically Insulating Materials

    NARCIS (Netherlands)

    de Winter, D.A.M.

    2015-01-01

    The Focused Ion Beam – Scanning Electron Microscope (FIB-SEM) is a versatile instrument originating from the semiconductor industry. The FIB is used to produce cross sections of pre-defined locations of interest, which are imaged and analyzed with the SEM. Repeated FIB cross sectioning and

  19. Pollen grain surface in Vaccinium myrtillus as seen in scanning electron microscopy

    Directory of Open Access Journals (Sweden)

    Józef Kocoń

    2014-01-01

    Full Text Available Pollen grain surface of Vaccinium myrtillus L. was analyzed by scanning electron microscopy. Pollen grains remain in tetrahedral tetrads. Grain surface is verrucose, consisting of thick, irregularly shaped muri, surrounding small, round or oval lumina. The surface of the muri is fissured, and minute papillae can also be noted.

  20. Scanning electron microscopic observation of the brown tumor of the head of mandible.

    Science.gov (United States)

    Tunali, Selcuk; Celik, Hamdi H; Uslu, Sabri S; Aldur, Mustafa M

    2005-05-01

    Brown tumors are tumor-like, expansile osteolytic lesions of bone which are seen in both primary and secondary hyperparathyroidism. They generally resolve after surgical treatment of the parathyroid adenoma. Here, we report a case of brown tumor of the mandible of a cadaver with its scanning electron microscopic observation and review of literature.

  1. THALLUS SURFACES IN COCCOCARPIACEAE AND PANNARIACEAE (LICHENIZED ASCOMYCETES) VIEWED WITH SCANNING ELECTRON-MICROSCOPY

    NARCIS (Netherlands)

    LUMBSCH, HT; KOTHE, HW

    1992-01-01

    The thallus surfaces of species belonging to the Coccocarpiaceae and Pannariaceae were studied using scanning electron microscopy (SEM). A pored epicortex was shown in Coccocarpia ssp., Degelia gayana and D. plumbea. In the other species studied no definite pores were found. The probable systematic

  2. Carbon-fiber tips for scanning probe microscopes and molecular electronics experiments

    NARCIS (Netherlands)

    Rubio-Bollinger, G.; Castellanos-Gomez, A.; Bilan, S.; Zotti, L.A.; Arroyo, C.R.; Agraït, N.; Cuevas, J.

    2012-01-01

    We fabricate and characterize carbon-fiber tips for their use in combined scanning tunneling and force microscopy based on piezoelectric quartz tuning fork force sensors. An electrochemical fabrication procedure to etch the tips is used to yield reproducible sub-100-nm apex. We also study electron

  3. Cold-induced imbibition damage of lettuce embryos: A study using cryo-scanning electron microscopy

    NARCIS (Netherlands)

    Nijsse, J.; Walther, P.; Hoekstra, F.

    2004-01-01

    The impact of rehydration on a multicellular organism was studied in lettuce (Lactuca sativa L.) embryos, using cryo-scanning electron microscopy (cryo-SEM). Naked embryos were sensitive to imbibitional stress, whereas embryos with an intact, thick-walled endosperm were not. Imbibitional injury to

  4. Low Energy Scanned Electron-Beam Dose Distribution in Thin Layers

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Hjortenberg, P. E.; Pedersen, Walther Batsberg

    1975-01-01

    on different backings (wood, aluminum, and iron) for scanned electron beams (Emax = 400 keV) having a broad energy spectrum and diffuse incidence, such as those used in radiation curing of coatings, textiles, plastics, etc. Theoretical calculations of such distributions of energy depositions are relatively...

  5. [Depth dose characteristics of electron beams released from a scanning type Racetrack Microtron treatment machine].

    Science.gov (United States)

    Sato, Tomoharu

    2002-01-01

    The Racetrack Microtron MM50 capable of taking out x-rays and electron beams having a high energy of up to 50 MeV was evaluated by a dosimetry of electron beams in comparison with Microtron MM22. The MM50 flattens the intensity of electron beams by using the beam scanning method while the MM22 utilizes the flattening-filter method. A percentage depth dose (PDD) curve was obtained through the dosimetry of electron beams using a water phantom. As compared with the MM22, the MM50 emits an electron beam that has an energy much closer to the nominal one, that is less contaminated by x-rays, and whose intensity decreases steeply down to near zero on the PDD curve. The MM50 has an electron beam dose distribution that is practically useful since the dose tends to be concentrated on the target volume.

  6. Analytical Formulae for Calculation of X-Ray Detector Solid Angles in the Scanning and Scanning/Transmission Analytical Electron Microscope

    Energy Technology Data Exchange (ETDEWEB)

    Zaluzec, Nestor J.

    2014-05-22

    Closed form analytical equations used to calculate the collection solid angle of six common geometries of solid-state X-ray detectors in scanning and scanning/transmission analytical electron microscopy are presented. Using these formulae one can make realistic comparisons of the merits of the different detector geometries in modern electron column instruments. This work updates earlier formulations and adds new detector configurations.

  7. High-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy.

    Science.gov (United States)

    Tapia, Juan Carlos; Kasthuri, Narayanan; Hayworth, Kenneth J; Schalek, Richard; Lichtman, Jeff W; Smith, Stephen J; Buchanan, JoAnn

    2012-01-12

    Conventional heavy metal poststaining methods on thin sections lend contrast but often cause contamination. To avoid this problem, we tested several en bloc staining techniques to contrast tissue in serial sections mounted on solid substrates for examination by field emission scanning electron microscopy (FESEM). Because FESEM section imaging requires that specimens have higher contrast and greater electrical conductivity than transmission electron microscopy (TEM) samples, our technique uses osmium impregnation (OTO) to make the samples conductive while heavily staining membranes for segmentation studies. Combining this step with other classic heavy metal en bloc stains, including uranyl acetate (UA), lead aspartate, copper sulfate and lead citrate, produced clean, highly contrasted TEM and scanning electron microscopy (SEM) samples of insect, fish and mammalian nervous systems. This protocol takes 7-15 d to prepare resin-embedded tissue, cut sections and produce serial section images.

  8. Imaging plant nuclei and membrane-associated cytoskeleton by field emission scanning electron microscopy.

    Science.gov (United States)

    Fišerová, Jindřiška; Goldberg, Martin W

    2014-01-01

    Scanning electron microscopy (SEM) is a powerful technique that can image exposed surfaces in 3D. Modern scanning electron microscopes, with field emission electron sources and in-lens specimen chambers, achieve resolutions of better than 0.5 nm and thus offer views of ultrastructural details of subcellular structures or even macromolecular complexes. Obtaining a reliable image is, however, dependent on sample preparation methods that robustly but accurately preserve biological structures. In plants, exposing the object of interest may be difficult due to the existence of a cell wall. This protocol shows how to isolate plant nuclei for SEM imaging of the nuclear envelope and associated structures from both sides of the nuclear envelope in cultured cells as well as in leaf or root cells. Further, it provides a method for uncovering membrane-associated cytoskeletal structures.

  9. A compilation of cold cases using scanning electron microscopy at the University of Rhode Island

    Science.gov (United States)

    Platek, Michael J.; Gregory, Otto J.

    2015-10-01

    Scanning electron microscopy combined with microchemical analysis has evolved into one of the most widely used instruments in forensic science today. In particular, the environmental scanning electron microscope (SEM) in conjunction with energy dispersive spectroscopy (EDS), has created unique opportunities in forensic science in regard to the examination of trace evidence; i.e. the examination of evidence without altering the evidence with conductive coatings, thereby enabling criminalists to solve cases that were previously considered unsolvable. Two cold cases were solved at URI using a JEOL 5900 LV SEM in conjunction with EDS. A cold case murder and a cold missing person case will be presented from the viewpoint of the microscopist and will include sample preparation, as well as image and chemical analysis of the trace evidence using electron microscopy and optical microscopy.

  10. Three-dimensional optical transfer functions in the aberration-corrected scanning transmission electron microscope.

    Science.gov (United States)

    Jones, L; Nellist, P D

    2014-05-01

    In the scanning transmission electron microscope, hardware aberration correctors can now correct for the positive spherical aberration of round electron lenses. These correctors make use of nonround optics such as hexapoles or octupoles, leading to the limiting aberrations often being of a nonround type. Here we explore the effect of a number of potential limiting aberrations on the imaging performance of the scanning transmission electron microscope through their resulting optical transfer functions. In particular, the response of the optical transfer function to changes in defocus are examined, given that this is the final aberration to be tuned just before image acquisition. The resulting three-dimensional optical transfer functions also allow an assessment of the performance of a system for focal-series experiments or optical sectioning applications. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  11. High field electron paramagnetic resonance spectroscopy under ultrahigh vacuum conditions—A multipurpose machine to study paramagnetic species on well defined single crystal surfaces

    Science.gov (United States)

    Rocker, J.; Cornu, D.; Kieseritzky, E.; Seiler, A.; Bondarchuk, O.; Hänsel-Ziegler, W.; Risse, T.; Freund, H.-J.

    2014-08-01

    A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of the resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic

  12. High field electron paramagnetic resonance spectroscopy under ultrahigh vacuum conditions—A multipurpose machine to study paramagnetic species on well defined single crystal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rocker, J.; Cornu, D.; Kieseritzky, E.; Hänsel-Ziegler, W.; Freund, H.-J. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Seiler, A. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Laboratorium für Applikationen der Synchrotronstrahlung, KIT Campus Süd, Kaiserstr. 12, 76131 Karlsruhe (Germany); Bondarchuk, O. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); CIC energiGUNE, Parque Tecnologico, C/Albert Einstein 48, CP 01510 Minano (Alava) (Spain); Risse, T., E-mail: risse@chemie.fu-berlin.de [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Institut für Chemie und Biochemie, Freie Universität Berlin, Takustr. 3, 14195 Berlin (Germany)

    2014-08-01

    A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of the resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic

  13. Computer Archiving and Image Enhancement of Diagnostic Electron Micrographs Using Scanning Transmission Electron Microscope as Real-Time Digitizer

    Science.gov (United States)

    Okagaki, T.; Jones, M.H.; Clark, B.A.; Pan, T.; Ferro, J.M.; Hsing, R.; Tzou, K.H.

    1984-01-01

    Diagnostic electron micrographs were digitized in real time using a scanning transmission electron microscope (STEM) controlled by a devoted front end processor at a resolution of 1K × 1K × 8. Various methods of image enhancement produced satisfactory results. From our experience, a faster front end processor with a larger memory size and 2K × 2K or 4K × 4K spatial resolution of an image are desirable. In order to facilitate storage and retrieval of an image archive, efficient data compression is necessary. ImagesFig. 2Fig. 3

  14. Note on in situ (scanning) transmission electron microscopy study of liquid samples.

    Science.gov (United States)

    Jiang, Nan

    2017-08-01

    Liquid cell (scanning) transmission electron microscopy has been developed rapidly, using amorphous SiNx membranes as electron transparent windows. The current interpretations of electron beam effects are mainly based on radiolytic processes. In this note, additional effects of the electric field due to electron-beam irradiation are discussed. The electric field can be produced by the charge accumulation due to the emission of secondary and Auger electrons. Besides various beam-induced phenomena, such as nanoparticle precipitation and gas bubble formation and motion, two other effects need to be considered; one is the change of Gibbs free energy of nucleation and the other is the violation of Brownian motion due to ion drifting driven by the electric field. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Carbon contamination in scanning transmission electron microscopy and its impact on phase-plate applications.

    Science.gov (United States)

    Hettler, Simon; Dries, Manuel; Hermann, Peter; Obermair, Martin; Gerthsen, Dagmar; Malac, Marek

    2017-05-01

    We analyze electron-beam induced carbon contamination in a transmission electron microscope. The study is performed on thin films potentially suitable as phase plates for phase-contrast transmission electron microscopy. Electron energy-loss spectroscopy and phase-plate imaging is utilized to analyze the contamination. The deposited contamination layer is identified as a graphitic carbon layer which is not prone to electrostatic charging whereas a non-conductive underlying substrate charges. Several methods that inhibit contamination are evaluated and the impact of carbon contamination on phase-plate imaging is discussed. The findings are in general interesting for scanning transmission electron microscopy applications. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  16. Atomic imaging using secondary electrons in a scanning transmission electron microscope: Experimental observations and possible mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Inada, H. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Hitachi High Technologies Corp., Ibaraki (Japan); Su, D. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Egerton, R.F. [University of Alberta, Edmonton (Canada); Konno, M. [Hitachi High Technologies Corp., Ibaraki (Japan); Wu, L.; Ciston, J.; Wall, J. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Zhu, Y., E-mail: zhu@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2011-06-15

    We report detailed investigation of high-resolution imaging using secondary electrons (SE) with a sub-nanometer probe in an aberration-corrected transmission electron microscope, Hitachi HD2700C. This instrument also allows us to acquire the corresponding annular dark-field (ADF) images both simultaneously and separately. We demonstrate that atomic SE imaging is achievable for a wide range of elements, from uranium to carbon. Using the ADF images as a reference, we studied the SE image intensity and contrast as functions of applied bias, atomic number, crystal tilt, and thickness to shed light on the origin of the unexpected ultrahigh resolution in SE imaging. We have also demonstrated that the SE signal is sensitive to the terminating species at a crystal surface. A possible mechanism for atomic-scale SE imaging is proposed. The ability to image both the surface and bulk of a sample at atomic-scale is unprecedented, and can have important applications in the field of electron microscopy and materials characterization. -- Research highlights: {yields} Atomic imaging using secondary electrons in an aberration-corrected electron microscope. {yields} High-resolution secondary electron imaging mechanism. {yields} Image contrast quantification and as functions of imaging conditions. {yields} Simultaneous acquisition of atomic images from surface and bulk.

  17. Cryo-Scanning Electron Microscopy (SEM) and Scanning Transmission Electron Microscopy (STEM)-in-SEM for Bio- and Organo-Mineral Interface Characterization in the Environment.

    Science.gov (United States)

    Wille, Guillaume; Hellal, Jennifer; Ollivier, Patrick; Richard, Annie; Burel, Agnes; Jolly, Louis; Crampon, Marc; Michel, Caroline

    2017-11-16

    Understanding biofilm interactions with surrounding substratum and pollutants/particles can benefit from the application of existing microscopy tools. Using the example of biofilm interactions with zero-valent iron nanoparticles (nZVI), this study aims to apply various approaches in biofilm preparation and labeling for fluorescent or electron microscopy and energy dispersive X-ray spectrometry (EDS) microanalysis for accurate observations. According to the targeted microscopy method, biofilms were sampled as flocs or attached biofilm, submitted to labeling using 4',6-diamidino-2-phenylindol, lectins PNA and ConA coupled to fluorescent dye or gold nanoparticles, and prepared for observation (fixation, cross-section, freezing, ultramicrotomy). Fluorescent microscopy revealed that nZVI were embedded in the biofilm structure as aggregates but the resolution was insufficient to observe individual nZVI. Cryo-scanning electron microscopy (SEM) observations showed nZVI aggregates close to bacteria, but it was not possible to confirm direct interactions between nZVI and cell membranes. Scanning transmission electron microscopy in the SEM (STEM-in-SEM) showed that nZVI aggregates could enter the biofilm to a depth of 7-11 µm. Bacteria were surrounded by a ring of extracellular polymeric substances (EPS) preventing direct nZVI/membrane interactions. STEM/EDS mapping revealed a co-localization of nZVI aggregates with lectins suggesting a potential role of EPS in nZVI embedding. Thus, the combination of divergent microscopy approaches is a good approach to better understand and characterize biofilm/metal interactions.

  18. Further observations on cerebellar climbing fibers. A study by means of light microscopy, confocal laser scanning microscopy and scanning and transmission electron microscopy.

    Science.gov (United States)

    Castejón, O J; Castejón, H V; Alvarado, M V

    2000-12-01

    The intracortical pathways of climbing fibers were traced in several vertebrate cerebella using light microscopy, confocal laser scanning microscopy, scanning and transmission electron microscopy. They were identified as fine fibers up to 1(micron thick, with a characteristic crossing-over bifurcation pattern. Climbing fiber collaterals were tridimensionally visualized forming thin climbing fiber glomeruli in the granular layer. Confocal laser scanning microscopy revealed three types of collateral processes at the interface between granular and Purkinje cell layers. Scanning electron microscopy showed climbing fiber retrograde collaterals in the molecular layer. Asymmetric synaptic contacts of climbing fibers with Purkinje dendritic spines and stellate neuron dendrites were characterized by transmission electron microscopy. Correlative microscopy allowed us to obtain the basic three-dimensional morphological features of climbing fibers in several vertebrates and to show with more accuracy a higher degree of lateral collateralization of these fibers within the cerebellar cortex. The correlative microscopy approach provides new views in the cerebellar cortex information processing.

  19. Effect of vacuum polarization on the excitation of hydrogen atom by electron impact

    Directory of Open Access Journals (Sweden)

    Sujata Bhattacharyya

    1981-01-01

    for 1S−2S excitation of the hydrogen atom by electron impact. The excitation amplitude calculated field theoretically is found to be lowered by 0.47t2/(t2+93 where t2=4|P−Q|2, P and Q being the momenta of the incident and scattered electrons respectively.

  20. Novel low-dose imaging technique for characterizing atomic structures through scanning transmission electron microscope

    Science.gov (United States)

    Su, Chia-Ping; Syu, Wei-Jhe; Hsiao, Chien-Nan; Lai, Ping-Shan; Chen, Chien-Chun

    2017-08-01

    To investigate dislocations or heterostructures across interfaces is now of great interest to condensed matter and materials scientists. With the advances in aberration-corrected electron optics, the scanning transmission electron microscope has demonstrated its excellent capability of characterizing atomic structures within nanomaterials, and well-resolved atomic-resolution images can be obtained through long-exposure data acquisition. However, the sample drifting, carbon contamination, and radiation damage hinder further analysis, such as deriving three-dimensional (3D) structures from a series of images. In this study, a method for obtaining atomic-resolution images with significantly reduced exposure time was developed, using which an original high-resolution image with approximately one tenth the electron dose can be obtained by combining a fast-scan high-magnification image and a slow-scan low-magnification image. The feasibility of obtaining 3D atomic structures using the proposed approach was demonstrated through multislice simulation. Finally, the feasibility and accuracy of image restoration were experimentally verified. This general method cannot only apply to electron microscopy but also benefit to image radiation-sensitive materials using various light sources.

  1. Ultra-high vacuum scanning tunnelling microscopy investigation of free radical adsorption to the Si(111)-7 x 7 surface

    Energy Technology Data Exchange (ETDEWEB)

    Guisinger, Nathan P; Elder, Shaun P; Yoder, Nathan L; Hersam, Mark C [Materials Science and Engineering Department, Northwestern University, 2220 Campus Drive, Evanston, IL 60208-3108 (United States)

    2007-01-31

    Room-temperature ultra-high vacuum (UHV) scanning tunnelling microscopy (STM) has been employed to investigate free radical chemistry on the Si(111)-7 x 7 surface with atomic-scale spatial resolution. In particular, due to its single-site binding mechanism and extensive previous study on the Si(100)-2 x 1 surface, the nitroxyl free radical 2,2,6,6-tetramethyl-1-piperidinyloxy (TEMPO) was explored. UHV STM imaging of isolated molecules revealed that TEMPO covalently reacts with adatom dangling bonds with high affinity. By monitoring TEMPO adsorption as a function of surface coverage, TEMPO was also found to preferentially bind to centre adatom sites at the initial stages of adsorption. On the other hand, as the surface coverage increased, TEMPO molecules adsorbed to centre adatoms and corner adatoms approached a ratio of 1:1. At all surface coverage levels, TEMPO showed minimal preference for binding to either the faulted or unfaulted half of the unit cell. Consequently, upon saturation, the TEMPO adlayer exhibited long-range ordering and preserved the underlying 7 x 7 surface reconstruction. This study provides fundamental insight into free radical surface chemistry and suggests a direct pathway for forming nearly perfectly ordered organic adlayers on the Si(111)-7 x 7 surface.

  2. Nanoscale Vacuum Channel Transistor.

    Science.gov (United States)

    Han, Jin-Woo; Moon, Dong-Il; Meyyappan, M

    2017-04-12

    Vacuum tubes that sparked the electronics era had given way to semiconductor transistors. Despite their faster operation and better immunity to noise and radiation compared to the transistors, the vacuum device technology became extinct due to the high power consumption, integration difficulties, and short lifetime of the vacuum tubes. We combine the best of vacuum tubes and modern silicon nanofabrication technology here. The surround gate nanoscale vacuum channel transistor consists of sharp source and drain electrodes separated by sub-50 nm vacuum channel with a source to gate distance of 10 nm. This transistor performs at a low voltage (3 microamperes). The nanoscale vacuum channel transistor can be a possible alternative to semiconductor transistors beyond Moore's law.

  3. Measuring of plasma properties induced by non-vacuum electron beam welding

    Science.gov (United States)

    Reisgen, U.; Schleser, M.; Abdurakhmanov, A.; Gumenyuk, A.

    2012-01-01

    Electron beam plasma measurement was realised by means of DIABEAM system invented by ISF RWTH Aachen. The Langmuir probe method is used for measurement. The relative simplicity of the method and the possibility of dispersion of high power on the probe allow its application for the investigation of high-power electron beams. The key element of the method is a rotating thin tungsten wire, which intersects the beam transversely on its axis and collects part of the current by itself. The signals, which are registered in the DIABEAM as a voltage, were taken in the form of amplitude. The conversion of the probe current into the distribution along the beam radius was realised using the Abel's method. A voltage-current characteristic was built for the beam current. The local electron density as well as the electron temperature, the floating potential and the plasma potential were measured and calculated by means of this characteristic.

  4. Secondary Electron Yield Measurements of Fermilab?s Main Injector Vacuum Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Scott, D.J.; Capista, D.; Duel, K.L.; Zwaska, R.M.; /Fermilab; Greenwald, S.; Hartung, W.; Li, Y.; Moore, T.P.; Palmer, M.A.; /Cornell U.; Kirby, R.; Pivi, M.; /SLAC

    2012-05-01

    We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.

  5. Comparison of Electron Imaging Modes for Dimensional Measurements in the Scanning Electron Microscope†

    Science.gov (United States)

    Postek, Michael T.; Vladár, András E.; Villarrubia, John S.; Muto, Atsushi

    2016-01-01

    Dimensional measurements from secondary electron (SE) images were compared with those from backscattered electron (BSE) and low-loss electron (LLE) images. With the commonly used 50% threshold criterion, the lines consistently appeared larger in the SE images. As the images were acquired simultaneously by an instrument with the capability to operate detectors for both signals at the same time, the differences cannot be explained by the assumption that contamination or drift between images affected the SE, BSE, or LLE images differently. Simulations with JMONSEL, an electron microscope simulator, indicate that the nanometer-scale differences observed on this sample can be explained by the different convolution effects of a beam with finite size on signals with different symmetry (the SE signal’s characteristic peak versus the BSE or LLE signal’s characteristic step). This effect is too small to explain the > 100 nm discrepancies that were observed in earlier work on different samples. Additional modeling indicates that those discrepancies can be explained by the much larger sidewall angles of the earlier samples, coupled with the different response of SE versus BSE/LLE profiles to such wall angles. PMID:27452278

  6. Scanning Electron Microscope Calibration Using a Multi-Image Non-Linear Minimization Process

    Science.gov (United States)

    Cui, Le; Marchand, Éric

    2015-04-01

    A scanning electron microscope (SEM) calibrating approach based on non-linear minimization procedure is presented in this article. A part of this article has been published in IEEE International Conference on Robotics and Automation (ICRA), 2014. . Both the intrinsic parameters and the extrinsic parameters estimations are achieved simultaneously by minimizing the registration error. The proposed approach considers multi-images of a multi-scale calibration pattern view from different positions and orientations. Since the projection geometry of the scanning electron microscope is different from that of a classical optical sensor, the perspective projection model and the parallel projection model are considered and compared with distortion models. Experiments are realized by varying the position and the orientation of a multi-scale chessboard calibration pattern from 300× to 10,000×. The experimental results show the efficiency and the accuracy of this approach.

  7. Depth sectioning with the aberration-corrected scanning transmission electron microscope

    Science.gov (United States)

    Borisevich, Albina Y.; Lupini, Andrew R.; Pennycook, Stephen J.

    2006-01-01

    The ability to correct the aberrations of the probe-forming lens in the scanning transmission electron microscope provides not only a significant improvement in transverse resolution but in addition brings depth resolution at the nanometer scale. Aberration correction therefore opens up the possibility of 3D imaging by optical sectioning. Here we develop a definition for the depth resolution for scanning transmission electron microscope depth sectioning and present initial results from this method. Objects such as catalytic metal clusters and single atoms on various support materials are imaged in three dimensions with a resolution of several nanometers. Effective focal depth is determined by statistical analysis and the contributing factors are discussed. Finally, current challenges and future capabilities available through new instruments are discussed. PMID:16492746

  8. Nanotubular Structure on the Ti-29Nb-5Zr Alloy by Scanning Transmission Electron Microscope.

    Science.gov (United States)

    Kim, Eun-Ju; Jeong, Yong-Hoon; Kang, Bo-An; Choe, Han-Cheol

    2015-01-01

    In this study, we reported the observation of highly ordered nanotubular structure on the Ti-29Nb-5Zr alloy in various potentials and electrolytes by field emission scanning electron microscopy and scanning transmission electron microscope. From the X-ray diffraction results and microstructure analysis, Ti-29Nb-5Zr alloy had β phase. The nanotube morphologies of Ti-29Nb-5Zr alloy were transformed from nano-porous structure to nanotube structure as NaF concentration and voltage increased. Nanotube diameter and layer changed with different concentration of NaF in 1 M H3PO4 at the same voltage. From the X-ray photoelectron spectroscopy results, nanotube was formed by Nb, Zr, and Ti oxide. Also, barrier layer of large tube was about 50 nm thickness, small one was 60 nm thickness. The nanotube size and crystallinity on the β Ti alloy was controlled by fluoride concentration, applied potential, anodization time, and tube layer.

  9. Field emission scanning electron microscopy of biofilm-growing bacteria involved in nosocomial infections.

    Science.gov (United States)

    Vuotto, Claudia; Donelli, Gianfranco

    2014-01-01

    Scanning electron microscopy (SEM) provides useful information on the shape, size, and localization within the biofilm of single bacteria as well as on the steps of biofilm formation process, on bacterial interactions, and on production of extracellular polymeric substances.When biofilms are constituted by microbial species involved in health care-associated infections, information provided by SEM can be fruitfully used not only for basic researches but also for diagnostic purposes.The protocols currently used in our laboratory for biofilm investigation by SEM are reported here. Particularly, the procedures to fix, dehydrate, and metalize in vitro-developed biofilms or ex vivo clinical specimens colonized by biofilm-growing microorganisms are described as well as the advantages of the observation of these samples by field emission scanning electron microscopy.

  10. Experimental Route to Scanning Probe Hot Electron Nanoscopy (HENs) Applied to 2D Material

    KAUST Repository

    Giugni, Andrea

    2017-06-09

    This paper presents details on a new experimental apparatus implementing the hot electron nanoscopy (HENs) technique introduced for advanced spectroscopies on structure and chemistry in few molecules and interface problems. A detailed description of the architecture used for the laser excitation of surface plasmons at an atomic force microscope (AFM) tip is provided. The photogenerated current from the tip to the sample is detected during the AFM scan. The technique is applied to innovative semiconductors for applications in electronics: 2D MoS2 single crystal and a p-type SnO layer. Results are supported by complementary scanning Kelvin probe microscopy, traditional conductive AFM, and Raman measurements. New features highlighted by HEN technique reveal details of local complexity in MoS2 and polycrystalline structure of SnO at nanometric scale otherwise undetected. The technique set in this paper is promising for future studies in nanojunctions and innovative multilayered materials, with new insight on interfaces.

  11. Scanning electron microscopy analysis of experimental bone hacking trauma of the mandible.

    Science.gov (United States)

    Alunni-Perret, Véronique; Borg, Cybèle; Laugier, Jean-Pierre; Bertrand, Marie-France; Staccini, Pascal; Bolla, Marc; Quatrehomme, Gérald; Muller-Bolla, Michèle

    2010-12-01

    The authors report on a macroscopic and microscopic study of human mandible bone lesions achieved by a single-blade knife and a hatchet. The aim of this work was to complete the previous data (scanning electron microscopy analysis of bone lesions made by a single-blade knife and a hatchet, on human femurs) and to compare the lesions of the femur with those of the mandible. The results indicate that the mandible is a more fragile bone, but the features observed on the mandible are quite similar to those previously observed on the femur. This work spells out the main scanning electron microscopy characteristics of sharp (bone cutting) and blunt (exerting a pressure on the bone) mechanisms on human bone. Weapon characteristics serve to explain all of these features.

  12. Scanning electron microscopy and transmission electron microscopy study of hot-deformed gamma-TiAl-based alloy microstructure.

    Science.gov (United States)

    Chrapoński, J; Rodak, K

    2006-09-01

    The aim of this work was to assess the changes in the microstructure of hot-deformed specimens made of alloys containing 46-50 at.% Al, 2 at.% Cr and 2 at.% Nb (and alloying additions such as carbon and boron) with the aid of scanning electron microscopy and transmission electron microscopy techniques. After homogenization and heat treatment performed in order to make diverse lamellae thickness, the specimens were compressed at 1000 degrees C. Transmission electron microscopy examinations of specimens after the compression test revealed the presence of heavily deformed areas with a high density of dislocation. Deformation twins were also observed. Dynamically recrystallized grains were revealed. For alloys no. 2 and no. 3, the recovery and recrystallization processes were more extensive than for alloy no. 1.

  13. High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy.

    Science.gov (United States)

    Krivanek, Ondrej L; Ursin, Jonathan P; Bacon, Neil J; Corbin, George J; Dellby, Niklas; Hrncirik, Petr; Murfitt, Matthew F; Own, Christopher S; Szilagyi, Zoltan S

    2009-09-28

    An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability comparable to systems using monochromators and spectrometers that are raised to near the high voltage of the instrument. It will also be able to correct the chromatic aberration of the probe-forming column. It should be able to provide variable energy resolution down to approximately 10 meV and spatial resolution less than 1 A.

  14. Applications of aberration corrected scanning transmission electron microscopy and electron energy loss spectroscopy to thin oxide films and interfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Varela del Arco, Maria [ORNL; Gazquez Alabart, Jaume [ORNL; Lupini, Andrew R [ORNL; Luck, Julia T [ORNL; Torija, Maria [University of Minnesota; Sharma, M [University of Minnesota; Leighton, chris [University of Minnesota; Biegalski, Michael D [ORNL; Christen, Hans M [ORNL; Murfitt, Matt [Nion Co; Dellby, Niklas [ORNL; Krivanek, Ondrej [ORNL; Pennycook, Stephen J [ORNL

    2010-01-01

    Aberration correction in the scanning transmission electron microscope allows spatial resolutions of the order of one ngstr m to be routinely achieved. When combined with electron energy loss spectroscopy, it is possible to simultaneously map the structure, the chemistry and even the electronic properties of materials in one single experiment. Here we will apply these techniques to the characterization of thin films and interfaces based on complex oxides with the perovskite structure. The relatively large lattice parameter of these materials combined with the fact that most of them have absorption edges within the reach of the spectrometer optics makes these materials ideal for these experiments. We will show how it is possible to map the chemistry of interfaces atomic plane by atomic plane, including light element imaging such as O. Applications to cobaltite and titanate thin films will be described.

  15. Submolecular Electronic Mapping of Single Cysteine Molecules by in Situ Scanning Tunneling Imaging

    DEFF Research Database (Denmark)

    Zhang, Jingdong; Chi, Qijin; Nazmutdinov, R. R.

    2009-01-01

    based on a slab model for the metal surface. The ordered monolayer offers a platform for submolecular scale electronic mapping that is an issue of fundamental interest but remains a challenge in STM imaging science and surface chemistry. Single Cys molecules were mapped as three electronic subunits......We have used L-Cysteine (Cys) as a model system to study the surface electronic structures of single molecules at the submolecular level in aqueous buffer solution by a combination of electrochemical scanning tunneling microscopy (in situ STM), electrochemistry including voltammetry...... contributed mainly from three chemical moieties: thiol (-SH), carboxylic (-COOH), and amine (-NH2) groups. The contrasts of the three subunits depend on the environment (e.g., pH), which affects the electronic structure of adsorbed species. From the DFT computations focused on single molecules, rational...

  16. Simulation of multicomponent losses in electron beam melting and refining at varying scan frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Powell, A.; Szekely, J. [Massachusetts Inst. of Tech., Cambridge, MA (United States); Van Den Avyle, J.; Damkroger, B. [Sandia National Labs., Albuquerque, NM (United States)

    1995-10-12

    A two-stage model is presented to describe alloy element evaporation rates from molten metal due to transient local heating by an electron beam. The first stage is a simulation of transient phenomena near the melt surface due to periodic heating by a scanning beam, the output of which is the relationship between operating parameters, surface temperature, and evaporation rate. At high scan rates, this can be done using a simple one-dimensional heat transfer model of the surface layer; at lower scan rates, a more complex three-dimensional model with fluid flow and periodic boundary conditions is necessary. The second stage couples this evaporation-surface temperature relationship with a larger steady state heat transfer and fluid flow model of an entire melting hearth or mold, in order to calculate local and total evaporation rates. Predictions are compared with experimental results from Sandia`s 310-kW electron beam melting furnace, in which evaporation rates and vapor compositions were studied in pure titanium and Ti-6%Al-4%V alloy. Evaporation rates were estimated from rate of condensation on a substrate held over the hearth, and were characterized as a function of beam power (150 and 225 kW), scan frequency (30, 115 and 450 Hz) and background pressure (10{sup {minus}3}, 10{sup {minus}4} and 10{sup {minus}5} torr).

  17. Visualizing Morphological Changes of Abscission Zone Cells in Arabidopsis by Scanning Electron Microscope.

    Science.gov (United States)

    Shi, Chun-Lin; Butenko, Melinka A

    2018-01-01

    Scanning electron microscope (SEM) is a type of electron microscope which produces detailed images of surface structures. It has been widely used in plants and animals to study cellular structures. Here, we describe a detailed protocol to prepare samples of floral abscission zones (AZs) for SEM, as well as further image analysis. We show that it is a powerful tool to detect morphologic changes at the cellular level during the course of abscission in wild-type plants and to establish the details of phenotypic alteration in abscission mutants.

  18. Reliable strain measurement in transistor arrays by robust scanning transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    Suhyun Kim

    2013-09-01

    Full Text Available Accurate measurement of the strain field in the channels of transistor arrays is critical for strain engineering in modern electronic devices. We applied atomic-resolution high-angle annular dark-field scanning transmission electron microscopy to quantitative measurement of the strain field in transistor arrays. The quantitative strain profile over 20 transistors was obtained with high reliability and a precision of 0.1%. The strain field was found to form homogeneously in the channels of the transistor arrays. Furthermore, strain relaxation due to the thin foil effect was quantitatively investigated for thicknesses of 35 to 275 nm.

  19. Focused ion beam (FIB)/scanning electron microscopy (SEM) in tissue structural research.

    Science.gov (United States)

    Leser, Vladka; Milani, Marziale; Tatti, Francesco; Tkalec, Ziva Pipan; Strus, Jasna; Drobne, Damjana

    2010-10-01

    The focused ion beam (FIB) and scanning electron microscope (SEM) are commonly used in material sciences for imaging and analysis of materials. Over the last decade, the combined FIB/SEM system has proven to be also applicable in the life sciences. We have examined the potential of the focused ion beam/scanning electron microscope system for the investigation of biological tissues of the model organism Porcellio scaber (Crustacea: Isopoda). Tissue from digestive glands was prepared as for conventional SEM or as for transmission electron microscopy (TEM). The samples were transferred into FIB/SEM for FIB milling and an imaging operation. FIB-milled regions were secondary electron imaged, back-scattered electron imaged, or energy dispersive X-ray (EDX) analyzed. Our results demonstrated that FIB/SEM enables simultaneous investigation of sample gross morphology, cell surface characteristics, and subsurface structures. The same FIB-exposed regions were analyzed by EDX to provide basic compositional data. When samples were prepared as for TEM, the information obtained with FIB/SEM is comparable, though at limited magnification, to that obtained from TEM. A combination of imaging, micro-manipulation, and compositional analysis appears of particular interest in the investigation of epithelial tissues, which are subjected to various endogenous and exogenous conditions affecting their structure and function. The FIB/SEM is a promising tool for an overall examination of epithelial tissue under normal, stressed, or pathological conditions.

  20. Thirty per cent contrast in secondary-electron imaging by scanning field-emission microscopy.

    Science.gov (United States)

    Zanin, D A; De Pietro, L G; Peter, Q; Kostanyan, A; Cabrera, H; Vindigni, A; Bähler, Th; Pescia, D; Ramsperger, U

    2016-11-01

    We perform scanning tunnelling microscopy (STM) in a regime where primary electrons are field-emitted from the tip and excite secondary electrons out of the target-the scanning field-emission microscopy regime (SFM). In the SFM mode, a secondary-electron contrast as high as 30% is observed when imaging a monoatomic step between a clean W(110)- and an Fe-covered W(110)-terrace. This is a figure of contrast comparable to STM. The apparent width of the monoatomic step attains the 1 nm mark, i.e. it is only marginally worse than the corresponding width observed in STM. The origin of the unexpected strong contrast in SFM is the material dependence of the secondary-electron yield and not the dependence of the transported current on the tip-target distance, typical of STM: accordingly, we expect that a technology combining STM and SFM will highlight complementary aspects of a surface while simultaneously making electrons, selected with nanometre spatial precision, available to a macroscopic environment for further processing.

  1. Magnification-continuous static calibration model of a scanning-electron microscope.

    OpenAIRE

    Malti, Abed Choaib; Dembélé, Sounkalo; Piat, Nadine; Rougeot, Patrick; Salut, Roland

    2012-01-01

    International audience; We present a new calibration model of both static distortion and projection for a scanning-electron microscope (SEM). The proposed calibration model depends continuously on the magnification factor. State-of-the-art methods have proposed models to solve the static distortion and projection model but for a discrete set of low and high magnifications: at low magnifications, existing models assume static distortion and perspective projection. At high magnifications, exist...

  2. Solving Research Tasks Using Desk top Scanning Electron Microscope Phenom ProX

    Directory of Open Access Journals (Sweden)

    Vertsanova, O.V.

    2014-03-01

    Full Text Available Phenom ProX — morden effective universal desktop Scanning Electron Microscope with integrated EDS system. Phenom-World helps customers to stay competitive in a world where critical dimensions are continuously getting smaller. All Phenom desktop systems give direct access to the high resolution and high-quality imaging and analysis required in a large variety of applications. They are affordable, flexible and a fast tool enabling engineers, technicians, researchers and educational professionals to investigate micron and submicron structures.

  3. Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy

    OpenAIRE

    Razavian, Hamid; Iranmanesh, Pedram; Mojtahedi, Hamid; Nazeri, Rahman

    2015-01-01

    Introduction: Presence of surface defects in endodontic instruments can lead to unwanted complications such as instrument fracture and incomplete preparation of the canal. The current study was conducted to evaluate the effect of autoclave cycles on surface characteristics of S-File by scanning electron microscopy (SEM). Methods and Materials: In this experimental study, 17 brand new S-Files (#30) were used. The surface characteristics of the files were examined in four steps (without autocla...

  4. Clinical and scanning electron microscopic assessments of porcelain and ceromer resin veneers.

    OpenAIRE

    Dhawan P; Prakash H; Shah N

    2003-01-01

    PURPOSE: Recently available Ceromer resin materials are promising for fabrication of esthetic anterior laminates and provices an alternative, cost effective treament modality to porcelain laminates for discolored anterior anterior teeth. It was proposed to study the esthetic quality and surface finish of veneers fbricated from ceromer resin and compare it with the standard porcelain veneers, both clinically as well as by scanning electron microscope (SEM) at baseline and at 12 months. If foun...

  5. Scanning electron microscopy and calcification in amelogenesis imperfecta in anterior and posterior human teeth

    OpenAIRE

    Sánchez-Quevedo, M.C.; Ceballos, G.; García, J. M.; Rodriguez, I. A.; Gómez de Ferraris, M.E.; Campos, Antonio

    2001-01-01

    Teeth fragments from members of a famil? clinically and genetically diagnosed as having amelogenesis imperfecta were studied by scanning electron microscopy and X-ray microprobe analysis to establish the morphological patterns and the quantitative concentration of calcium in the enamel of anterior (canine, incisor) and posterior (premolar and molar) teeth. The prism patterns in the enamel of teeth from both regions were parallel or irregularly decussate, with ...

  6. Scanning electron microscopy of the egg-shell of the fly synthesiomyia Nudiseta (wulp)

    OpenAIRE

    El Alfy, Nagla Z. [نجلاء زكي الالفي

    1994-01-01

    The ultrastructure of the egg-shell of the fly Synthesiomyia nudiseta has been studied by scanning electron microscopy. The surface of the outer chorion is highly ridged, grooved and has a reticulate appearance except at the collar surrounding the micropyle. There are few aeropyles at the antimicropylar pole. The structure of the egg-shell outside the hatching lines is composed of three layers. The outer layer consists of vertical columns that arise from the middle layer, these columns bra...

  7. Scanning electron microscopy of the teguments of males from five populations of Schistosoma mattheei.

    Science.gov (United States)

    Kruger, F J; Hamilton-Attwell, V L; Schutte, C H

    1986-06-01

    The teguments of males from 5 populations of S. mattheei, of which 3 were sympatric and 2 allopatric with S. haematobium, were studied by means of scanning electron microscopy (SEM). A certain percentage of the males of each sympatric population bore tubercle spines while the allopatric populations were spineless. It is postulated that the presence of tubercle spines is a characteristic inherited from S. haematobium.

  8. Scanning electron microscopical observations on the shedding of the tegument of adult Schistosoma mattheei.

    Science.gov (United States)

    Kruger, F J; Joubert, P H

    1990-11-01

    In search of indications of membrane turnover the teguments of male Schistosoma mattheei from cattle and laboratory rodents were studied by means of scanning electron microscopy. A number of slightly elevated circular patches of tegument which appeared to peel off on the edges were seen on the outer membrane of a limited number of specimens from both rodents and cattle. It is suggested that this phenomenon may represent limited rapid turnover of the outer layer in response to host immunological action.

  9. Scanning Electron Microscopic Evaluation of Root Canal Irrigation with Saline, Sodium Hypochlorite, and Citric Acid,

    Science.gov (United States)

    1983-12-01

    endodontic techniques; citric acid for root canal irrigation 4410,ABSTACgmf --,-,m- ,-rms n roc"---’This Study used a scanning electron microscope and a...wall is instrumented during canal preparation and that the smeared layer seems to be found only where endodontic instruments have scraped the surface...between the extremes. It was also decided to use a magnification of 75X to evaluate the superficial debris and 800X to evaluate the smeared layer

  10. The Dentin Tubule System: A Replica and Scanning Electron Microscope Study.

    Science.gov (United States)

    1978-06-20

    this laboratory to prepare soft and calci fied tissues for scanning and transmission electron microscopy. The resolution, magnification range and...several intertubular connections , originally examined at a magnification of 17,000 times (Fig. 7). In addition to the omnipresent lateral tubule...branches , and the ease of penetration therein of endodontic reagents from the pulp. Intratubular network throughout the dentin may be a route of intra

  11. Scanning Electron Microscopy study of Macbat regeneration effect on lead-acid battery electrodes

    OpenAIRE

    Emanuelsson, Christian

    2013-01-01

    Electrodes from lead-acid batteries were studied using scanning electron microscopy and energy dispersive spectroscopy. This to observe the effects of cycling on the batteries and how a capacity recovery process, known as Macbat regeneration, affected the active material with focus on hard sulphation. First, two new batteries were cycled for two months and electrodes from them were studied when the batteries were new, cycled, fully charged after cycling and regenerated after cycling. Then ele...

  12. Corneal endothelium of the Magellanic penguin (Spheniscus magellanicus) by scanning electron microscopy.

    Science.gov (United States)

    Pigatto, João A T; Laus, José L; Santos, Jaime M; Cerva, Cristine; Cunha, Luciana S; Ruoppolo, Valéria; Barros, Paulo S M

    2005-12-01

    The corneal endothelium is essential for the maintenance of the corneal transparency. The aim of this study was to examine the morphology of the endothelial surface and perform morphometric analysis of the normal corneal endothelial cells of the Magellanic penguin (Spheniscus magellanicus) using scanning electron microscopy. The present work demonstrates that the corneal endothelium of the Magellanic penguin is similar to those described in other vertebrates.

  13. Intensity interferometry experiments in a scanning transmission electron microscope : physics and applications

    OpenAIRE

    Meuret, Sophie

    2015-01-01

    Quantum optics performed at the nanometer scale is an important challenge, especially for quantum emitters characterization. They can be point defects in material (few ang- ströms) or confined structures of a few nanometers. A way to reach this scale is by using cathodoluminescence (CL) performed in a scanning transmission electron microscope (CL- STEM), which has only recently been done [1]. However, when aiming at studying the statistical properties of the light coming out of a CL experimen...

  14. Vison and visual servoing for nanomanipulation and nanocharacterization using scanning electron microscope

    OpenAIRE

    Marturi, Naresh

    2013-01-01

    With the latest advances in nanotechnology, it became possible to design novel nanoscale devicesand systems with increasing efficiency. The consequence of this fact is an increase in the need for developing reliable and cutting edge processes for nanomanipulation and nanocharacterization. Since the human direct sensing is not a feasible option at this particular scale, the tasks are usually performedby an expert human operator using a scanning electron microscope (SEM) equipped withmicro-nano...

  15. Histology and scanning electron microscopy observations of cryopreserved protocorm-like bodies of Dendrobium sonia-28

    OpenAIRE

    POOBATHY, Ranjetta; Sinniah, Uma Rani; RATHINAM, Xavier; Subramaniam, Sreeramanan

    2013-01-01

    The genus Dendrobium possesses horticultural importance. Dendrobium sonia-28 is an important ornamental orchid in the flower industry. Cryopreservation is a favoured long-term storage method for orchids with propagation problems. Protocorm-like bodies (PLBs) of Dendrobium sonia-28 were cryopreserved using the vitrification technique. Histology and scanning electron microscopy (SEM) observations were conducted on stock, non-cryopreserved (control), and cryopreserved PLBs of Dendrobium sonia-28...

  16. A scanning electron microscopic evaluation of different root canal irrigation regimens

    OpenAIRE

    Chaves Medici Mônika; Izabel Cristina Fröner

    2006-01-01

    The purpose of this study was to assess the effectiveness of endodontic irrigants in removing the smear layer from instrumented root canal walls using Scanning Electron Microscopy (SEM). The endodontic irrigants used were: 1% sodium hypochlorite (NaOCl); 1% NaOCl mixed to 17% EDTAC; 2% chlorhexidine gel; and Ricinus communis gel. Photomicrographs of the middle and apical thirds were evaluated with the aid of the Fotoscore - v. 2.0 software. The results indicated that the mixture of sodium hyp...

  17. SCANNING ELECTRON MICROSCOPIC INVESTIGATION OF DENTINAL TUBULES IN MONKEY DENTIN SCANNING ELECTRON MICROSCOPIC INVESTIGATION OF DENTINAL TUBULES IN Cebus apella DENTIN

    Directory of Open Access Journals (Sweden)

    João Humberto Antoniazzi

    2009-12-01

    Full Text Available

    The aim of the study was to investigate the number and diameter of the Cebus apella dentinal tubules. The roots of the Cebus apella teeth were examined in specific tooth locations: the apical, middle and cervical dentin. The calculations were based on the scanning electron microscope photographs of the fractured surfaces. The results showed that the average number of dentinal tubules for each location was: 74,800 tubules/mm2 for apical root dentin, 90,000 tubules/mm2 for mid-root dentin, 91,600 tubules/mm2 for cervical root dentin. The average diameter was the following: apical root dentin, 4,30µm; mid-root dentin, 4,37µm; cervical root dentin,  5,23µm. These findings demonstrate that the Cebus apella teeth are a suitable substitute for human in endodontics studies. 

    KEY WORDS: Dentin, dentinal tubules, teeth.
    The aim of the study was to investigate the number and diameter of the Cebus apella dentinal tubules. The roots of the Cebus apella teeth were examined in specific tooth locations: the apical, middle and cervical dentin. The calculations were based on the scanning electron microscope photographs of the fractured surfaces. The results showed that the average number of dentinal tubules for each location was: 74,800 tubules/mm2 for apical root dentin, 90,000 tubules/mm2 for mid-root dentin, 91,600 tubules/mm2 for cervical root dentin. The average diameter was the following: apical root dentin, 4,30µm; mid-root dentin, 4,37µm; cervical root dentin,  5,23µm. These findings demonstrate that the Cebus apella teeth are a suitable substitute for human in endodontics studies. 

    KEY WORDS: Dentin, dentinal tubules, teeth.

  18. Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography.

    Science.gov (United States)

    Trépout, Sylvain; Bastin, Philippe; Marco, Sergio

    2017-03-12

    This report describes a protocol for preparing thick biological specimens for further observation using a scanning transmission electron microscope. It also describes an imaging method for studying the 3D structure of thick biological specimens by scanning transmission electron tomography. The sample preparation protocol is based on conventional methods in which the sample is fixed using chemical agents, treated with a heavy atom salt contrasting agent, dehydrated in a series of ethanol baths, and embedded in resin. The specific imaging conditions for observing thick samples by scanning transmission electron microscopy are then described. Sections of the sample are observed using a through-focus method involving the collection of several images at various focal planes. This enables the recovery of in-focus information at various heights throughout the sample. This particular collection pattern is performed at each tilt angle during tomography data collection. A single image is then generated, merging the in-focus information from all the different focal planes. A classic tilt-series dataset is then generated. The advantage of the method is that the tilt-series alignment and reconstruction can be performed using standard tools. The collection of through-focal images allows the reconstruction of a 3D volume that contains all of the structural details of the sample in focus.

  19. Construction of a four tip scanning tunneling microscope/scanning electron microscope combination and conductivity measurements of silicide nanowires; Aufbau einer Vierspitzen-Rastertunnelmikroskop/Rasterelektronenmikroskop-Kombination und Leitfaehigkeitsmessungen an Silizid Nanodraehten

    Energy Technology Data Exchange (ETDEWEB)

    Zubkov, Evgeniy

    2013-09-01

    In this work the combination of a four-tip scanning tunneling microscope with a scanning electron microscope is presented. By means of this apparatus it is possible to perform the conductivity measurements on the in-situ prepared nanostructures in ultra-high vacuum. With the aid of a scanning electron microscope (SEM), it becomes possible to position the tunneling tips of the four-tip scanning tunneling microscope (STM), so that an arrangement for a four-point probe measurement on nanostructures can be obtained. The STM head was built according to the novel coaxial Beetle concept. This concept allows on the one hand, a very compact arrangement of the components of the STM and on the other hand, the new-built STM head has a good mechanical stability, in order to achieve atomic resolution with all four STM units. The atomic resolution of the STM units was confirmed by scanning a Si(111)-7 x 7 surface. The thermal drift during the STM operation, as well as the resonant frequencies of the mechanical structure of the STM head, were determined. The scanning electron microscope allows the precise and safe navigation of the tunneling tips on the sample surface. Multi tip spectroscopy with up to four STM units can be performed synchronously. To demonstrate the capabilities of the new-built apparatus the conductivity measurements were carried out on metallic yttrium silicide nanowires. The nanowires were prepared by the in-situ deposition of yttrium on a heated Si(110) sample surface. Current-voltage curves were recorded on the nanowires and on the wetting layer in-between. The curves indicate an existence of the Schottky barrier between the yttrium silicide nanowires and the silicon bulk. By means of the two-tip measurements with a gate, the insulating property of the Schottky barrier has been confirmed. Using this Schottky barrier, it is possible to limit the current to the nanowire and to prevent it from flowing through the silicon bulk. A four-tip resistance measurement

  20. First accelerator test of vacuum components with laser-engineered surfaces for electron-cloud mitigation

    Science.gov (United States)

    Calatroni, Sergio; Garcia-Tabares Valdivieso, Elisa; Neupert, Holger; Nistor, Valentin; Perez Fontenla, Ana Teresa; Taborelli, Mauro; Chiggiato, Paolo; Malyshev, Oleg; Valizadeh, Reza; Wackerow, Stefan; Zolotovskaya, Svetlana A.; Gillespie, W. Allan; Abdolvand, Amin

    2017-11-01

    Electron cloud mitigation is an essential requirement for high-intensity proton circular accelerators. Among other solutions, laser engineered surface structures (LESS) present the advantages of having potentially a very low secondary electron yield (SEY) and allowing simple scalability for mass production. Two copper liners with LESS have been manufactured and successfully tested by monitoring the electron cloud current in a dipole magnet in the SPS accelerator at CERN during the 2016 run. In this paper we report on these results as well as the detailed experiments carried out on samples—such as the SEY and topography studies—which led to an optimized treatment in view of the SPS test and future possible use in the HL-LHC.

  1. Quantification of carbon contamination under electron beam irradiation in a scanning transmission electron microscope and its suppression by plasma cleaning

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, A J V; Walther, T, E-mail: t.walther@sheffield.ac.u [Department of Electronic and Electrical Engineering, University of Sheffield, Sir Frederick Mappin Building, Mappin Street, Sheffield S1 3JD (United Kingdom)

    2010-07-01

    We have measured the build-up of carbon surface contamination as a function of time and irradiated area size for various specimens in a JEOL 2010F (scanning) transmission electron microscope, employing both t/{lambda} mapping with our Gatan imaging filter and recording changes in annular dark-field image intensity. It is shown that the total number of carbon atoms deposited per time for a given beam intensity is roughly constant at room temperature for as-received specimens while it is significantly lower for plasma cleaned specimens. This explains why contamination is generally only an issue at the highest magnifications where the contamination regions become smaller and the carbon layers correspondingly thicker. A Fischione plasma cleaner was then used to remove these carbon layers, and the rate of carbon removal has been determined for contamination spots produced in stationary spot mode as well as for extended regions scanned for a minute so that optimal cleaning times can be chosen.

  2. Dynamic investigation of electron trapping and charge decay in electron-irradiated Al sub 2 O sub 3 in a scanning electron microscope: Methodology and mechanisms

    CERN Document Server

    Fakhfakh, S; Belhaj, M; Fakhfakh, Z; Kallel, A; Rau, E I

    2002-01-01

    The charging and discharging of polycrystalline Al sub 2 O sub 3 submitted to electron-irradiation in a scanning electron microscope (SEM) are investigated by means of the displacement current method. To circumvent experimental shortcomings inherent to the use of the basic sample holder, a redesign of the latter is proposed and tests are carried out to verify its operation. The effects of the primary beam accelerating voltage on charging, flashover and discharging phenomena during and after electron-irradiation are studied. The experimental results are then analyzed. In particular, the divergence between the experimental data and those predicted by the total electron emission yield approach (TEEYA) is discussed. A partial discharge was observed immediately after the end of the electron-irradiation exposure. The experimental data suggests, that the discharge is due to the evacuation to the ground, along the insulator surface, of released electrons from shallow traps at (or in the close vicinity of) the insulat...

  3. The Study of Advanced Accelerator Physics Research at UCLA Using the ATF at BNL: Vacuum Acceleration by Laser of Free Electrons

    Energy Technology Data Exchange (ETDEWEB)

    Cline, David B. [Univ. of California, Los Angeles, CA (United States)

    2016-09-07

    An experiment was designed and data were taken to demonstrate that a tightly focused laser on vacuum can accelerate an electron beam in free space. The experiment was proof-of-principle and showed a clear effect for the laser beam off and on. The size of the effect was about 20% and was consistent over 30 laser and beam shots.

  4. The electronic states of 1,2,3-triazole studied by vacuum ultraviolet photoabsorption and ultraviolet photoelectron spectroscopy, and a comparison with ab initio configuration interaction methods

    DEFF Research Database (Denmark)

    Palmer, Michael H.; Hoffmann, Søren Vrønning; Jones, Nykola C.

    2011-01-01

    The Rydberg states in the vacuum ultraviolet photoabsorption spectrum of 1,2,3-triazole have been measured and analyzed with the aid of comparison to the UV valence photoelectron ionizations and the results of ab initio configuration interaction (CI) calculations. Calculated electronic ionization...

  5. Specimen preparation by ion beam slope cutting for characterization of ductile damage by scanning electron microscopy.

    Science.gov (United States)

    Besserer, Hans-Bernward; Gerstein, Gregory; Maier, Hans Jürgen; Nürnberger, Florian

    2016-04-01

    To investigate ductile damage in parts made by cold sheet-bulk metal forming a suited specimen preparation is required to observe the microstructure and defects such as voids by electron microscopy. By means of ion beam slope cutting both a targeted material removal can be applied and mechanical or thermal influences during preparation avoided. In combination with scanning electron microscopy this method allows to examine voids in the submicron range and thus to analyze early stages of ductile damage. In addition, a relief structure is formed by the selectivity of the ion bombardment, which depends on grain orientation and microstructural defects. The formation of these relief structures is studied using scanning electron microscopy and electron backscatter diffraction and the use of this side effect to interpret the microstructural mechanisms of voids formation by plastic deformation is discussed. A comprehensive investigation of the suitability of ion beam milling to analyze ductile damage is given at the examples of a ferritic deep drawing steel and a dual phase steel. © 2016 Wiley Periodicals, Inc.

  6. Contrast and decay of cathodoluminescence from phosphor particles in a scanning electron microscope.

    Science.gov (United States)

    den Engelsen, Daniel; Harris, Paul G; Ireland, Terry G; Fern, George R; Silver, Jack

    2015-10-01

    Cathodoluminescence (CL) studies are reported on phosphors in a field emission scanning electron microscope (FESEM). ZnO: Zn and other luminescent powders manifest a bright ring around the periphery of the particles: this ring enhances the contrast. Additionally, particles resting on top of others are substantially brighter than underlying ones. These phenomena are explained in terms of the combined effects of electrons backscattered out of the particles, together with light absorption by the substrate. The contrast is found to be a function of the particle size and the energy of the primary electrons. Some phosphor materials exhibit a pronounced comet-like structure at high scan rates in a CL-image, because the particle continues to emit light after the electron beam has moved to a position without phosphor material. Image analysis has been used to study the loss of brightness along the tail and hence to determine the decay time of the materials. The effect of phosphor saturation on the determination of decay times by CL-microscopy was also investigated. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Three-dimensional imaging of cerebellar mossy fiber rosettes by ion-abrasion scanning electron microscopy.

    Science.gov (United States)

    Kim, Hyun-Wook; Kim, Namkug; Kim, Ki Woo; Rhyu, Im Joo

    2013-08-01

    The detailed knowledge of the three-dimensional (3D) organization of the nervous tissue provides essential information on its functional elucidation. We used serial block-face scanning electron microscopy with focused ion beam (FIB) milling to reveal 3D morphologies of the mossy fiber rosettes in the mice cerebellum. Three-week-old C57 black mice were perfused with a fixative of 1% paraformaldehyde/1% glutaraldehyde in phosphate buffer; the cerebellum was osmicated and embedded in the Araldite. The block containing granule cell layer was sliced with FIB and observed by field-emission scanning electron microscopy. The contrast of backscattered electron image of the block-face was similar to that of transmission electron microscopy and processed using 3D visualization software for further analysis. The mossy fiber rosettes on each image were segmented and rendered to visualize the 3D model. The complete 3D characters of the mossy fiber rosette could be browsed on the A-Works, in-house software, and some preliminary quantitative data on synapse of the rosette could be extracted from these models. Thanks to the development of two-beam imaging and optimized software, we could get 3D information on cerebellar mossy fiber rosettes with ease and speedily, which would be an additive choice to explore 3D structures of the nervous systems and their networks.

  8. Facile synthesis and electron transport properties of NiO nanostructures investigated by scanning tunneling microscopy

    Directory of Open Access Journals (Sweden)

    Govind Mallick

    2017-08-01

    Full Text Available Due to their unique chemical, thermal, electronic and photonic properties, low -dimensional transition metal oxides, especially NiO, have attracted great deal of attention for potential applications in a wide range of technologies, such as, sensors, electrochromic coatings and self-healing materials. However, their synthesis involves multi-step complex procedures that in addition to being expensive, further introduce impurities. Here we present a low cost facile approach to synthesize uniform size NiO nanoparticles (NPs from hydrothermally grown Ni(OH2. Detailed transmission electron microscopic analysis reveal the average size of NiO NPs to be around 29 nm. The dimension of NiO NP is also corroborated by the small area scanning tunneling microscope (STM measurements. Further, we investigate electron transport characteristics of newly synthesized Ni(OH2 and NiO nanoparticles on p-type Si substrate using scanning tunneling microscopy. The conductivity of Ni(OH2 and NiO are determined to be 1.46x10-3 S/cm and 2.37x10-5 S/cm, respectively. The NiO NPs exhibit a lower voltage window (∼0.7 V electron tunneling than the parent Ni(OH2.

  9. Facile synthesis and electron transport properties of NiO nanostructures investigated by scanning tunneling microscopy

    Science.gov (United States)

    Mallick, Govind; Labh, Jyotsna; Giri, Lily; Pandey, Avinash C.; Karna, Shashi P.

    2017-08-01

    Due to their unique chemical, thermal, electronic and photonic properties, low -dimensional transition metal oxides, especially NiO, have attracted great deal of attention for potential applications in a wide range of technologies, such as, sensors, electrochromic coatings and self-healing materials. However, their synthesis involves multi-step complex procedures that in addition to being expensive, further introduce impurities. Here we present a low cost facile approach to synthesize uniform size NiO nanoparticles (NPs) from hydrothermally grown Ni(OH)2. Detailed transmission electron microscopic analysis reveal the average size of NiO NPs to be around 29 nm. The dimension of NiO NP is also corroborated by the small area scanning tunneling microscope (STM) measurements. Further, we investigate electron transport characteristics of newly synthesized Ni(OH)2 and NiO nanoparticles on p-type Si substrate using scanning tunneling microscopy. The conductivity of Ni(OH)2 and NiO are determined to be 1.46x10-3 S/cm and 2.37x10-5 S/cm, respectively. The NiO NPs exhibit a lower voltage window (˜0.7 V) electron tunneling than the parent Ni(OH)2.

  10. Chemical-state imaging of Li using scanning Auger electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Nobuyuki, E-mail: ISHIDA.Nobuyuki@nims.go.jp [Global Research Center for Environment and Energy based on Nanomaterials Science (GREEN), National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Fujita, Daisuke [Global Research Center for Environment and Energy based on Nanomaterials Science (GREEN), National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Advanced Nanocharacterization Unit, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan)

    2013-02-15

    Highlights: •Scanning Auger electron microscopy is used to image chemical states of Li. •The combined use of AES and EELS signals for the elemental mapping is powerful. •Distribution corresponding to metallic and oxidized states of Li can be imaged. -- Abstract: The demand for measurement tools to detect Li with high spatial resolution and precise chemical sensitivity is increasing with the spread of lithium-ion batteries (LIBs) for use in a wide range of applications. In this work, scanning Auger electron microscopy (SAM) is used to image chemical states of a partially oxidized Li surface on the basis of the Auger electron spectroscopy (AES) and electron energy loss spectroscopy (EELS) data obtained during an oxidation process of a metal Li. We show that distribution of metallic and oxidized states of Li is clearly imaged by mapping the intensity of the corresponding AES and EELS peaks. Furthermore, a tiny difference in the extent of oxidation can be distinguished by comparing the elemental map of an AES peak with that of an EELS peak owing to the different behaviors of those signals to the chemical states of Li.

  11. Industrial Robot Automation in Solving Non-Vacuum Electron-Beam Welding Problems

    OpenAIRE

    Borovik Vasiliy; Shatravin Vladislav; Junusov Il’jas; Shashev Dmitri; Kornilov Sergei; Rempe Nikolai; Shidlovskiy Stanislav

    2016-01-01

    The paper describes one modeling automated hardware-software system to develop additive technologically - based products. Algorithm synthesis for industrial robot control was performed. In this case, the operating tool is an electron -beam projector with plasma emitter. The model testing results of thermal processes (in 3D-enqueuing) proceeding within additive substrate material system have been described. The modeling results revealed those required parameters of emission power which would p...

  12. Aberration-corrected scanning transmission electron microscopy: the potential for nano- and interface science

    Energy Technology Data Exchange (ETDEWEB)

    Pennycook, S.J.; Pantelides, S.T. [Solid State Div., Oak Ridge National Lab., Oak Ridge, TN (United States); Dept. of Physics and Astronomy, Vanderbilt Univ., Nashville, TN (United States); Lupini, A.R.; Wang, L.G. [Solid State Div., Oak Ridge National Lab., Oak Ridge, TN (United States); Kadavanich, A. [Solid State Div., Oak Ridge National Lab., Oak Ridge, TN (United States); Dept. of Chemistry, Vanderbilt Univ., Nashville, TN (United States); McBride, J.R. [Dept. of Chemistry, Vanderbilt Univ., Nashville, TN (United States); Rosenthal, S.J. [Dept. of Physics and Astronomy, Vanderbilt Univ., Nashville, TN (United States); Puetter, R.C.; Yahil, A. [Pixon LLC, Stony Brook, NY (United States); Krivanek, O.L.; Dellby, N.; Nellist, P.D.L. [Nion Co., Kirkland, WA (United States); Duscher, G. [Solid State Div., Oak Ridge National Lab., Oak Ridge, TN (United States); Dept. of Materials Science and Engineering, North Carolina State Univ., Raleigh, NC (United States)

    2003-04-01

    The sub-Aangstroem probe of an aberration-corrected scanning transmission electron microscope will enable imaging and analysis of nanostructures and interfaces with unprecedented resolution and sensitivity. In conjunction with first-principles theory, new insights are anticipated into the atomistic processes of growth and the subtle link between structure and functionality. We present initial results from the aberration-corrected microscopes at Oak Ridge National Laboratory that indicate the kinds of studies that will become feasible in the near future. Examples include (1) the three-dimensional location and identification of individual dopant and impurity atoms in semiconductor interfaces, and their effect on local electronic structure; (2) the accurate reconstruction of surface atomic and electronic structure on nanocrystals, and the effect on optical properties; and (3) the ability to distinguish which configurations of catalyst atoms are active, and why. (orig.)

  13. High-resolution characterization of multiferroic heterojunction using aberration-corrected scanning transmission electron microscopy

    Science.gov (United States)

    Yuan, Zhoushen; Ruan, Jieji; Xie, Lin; Pan, Xiaoqing; Wu, Di; Wang, Peng

    2017-04-01

    Multiferroic tunnel junctions have been considered as potential candidates for nonvolatile memory devices. Understanding the atomic structure at the interface is crucial for optimizing the performances in such oxide electronics. Spatially resolved electron energy loss spectroscopy (EELS) combined with aberration-corrected scanning transmission electron microscopy is employed to measure the compositional profiles across the interfaces of different layers with atomic resolution. Two-dimensional elemental imaging with atomic resolution is demonstrated, and the influences of the interface sharpness, the terminal layer, and cation intermixing are investigated. An asymmetric sublattice intermixing at the Pr0.8Ca0.2MnO3/BaTiO3/La0.7Sr0.3MnO3 interface is observed, which can affect the local Mn valence and coupling. The reduction in the Mn valence at the interface is further studied using EELS near-edge fine structures.

  14. A menu of electron probes for optimising information from scanning transmission electron microscopy.

    Science.gov (United States)

    Nguyen, D T; Findlay, S D; Etheridge, J

    2018-01-01

    We assess a selection of electron probes in terms of the spatial resolution with which information can be derived about the structure of a specimen, as opposed to the nominal image resolution. Using Ge [001] as a study case, we investigate the scattering dynamics of these probes and determine their relative merits in terms of two qualitative criteria: interaction volume and interpretability. This analysis provides a 'menu of probes' from which an optimum probe for tackling a given materials science question can be selected. Hollow cone, vortex and spherical wave fronts are considered, from unit cell to Ångstrom size, and for different defocus and specimen orientations. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. The Observation of Martensite and Magnetic Domain Structures in Ni53Mn24Ga23 Shape Memory Alloys by Scanning Electron Acoustic Microscopy and Scanning Thermal Microscopy

    Science.gov (United States)

    Zhao, Kun-Yu; Zeng, Hua-Rong; Song, Hong-Zhang; Hui, Sen-Xing; Li, Guo-Rong; Yin, Qing-Rui

    2012-05-01

    We present observations of martensite variants and ferromagnetic domain structures of Ni53Mn24Ga23 ferromagnetic shape memory alloys with a pure tetragonal martensitic phase by using scanning electron acoustic microscopy (SEAM) and scanning thermal microscopy (SThM). Electron acoustic images show a polycrystalline morphology with martensite variants. Direct coincidence between crystallographic martensitic twin variants and magnetic domains is found. A domain-like structure, obtained by SThM, is firstly reported, and then confirmed by magnetic force microscopy (MFM). The experimental results will be helpful for investigating the local thermal properties of ferromagnets and understanding the relationship between martensite variants and magnetic domains.

  16. Fundamental and experimental aspects of diffraction for characterizing dislocations by electron channeling contrast imaging in scanning electron microscope.

    Science.gov (United States)

    Kriaa, H; Guitton, A; Maloufi, N

    2017-08-29

    Nowadays Field Emission Gun-Scanning Electron Microscopes provide detailed crystallographic information with high spatial and angular resolutions, and allow direct observation of crystalline defects, such as dislocations, through an attractive technique called Electron Channeling Contrast Imaging (ECCI). Dislocations play a crucial role in the properties of materials and ECCI has naturally emerged as an adapted tool for characterizing defects in bulk specimen. Nevertheless, fine control of the channeling conditions is absolutely required to get strong dislocation contrast for achieving comprehensive analysis. In this work, experiment-assisted fundamental aspects of the origin of dislocation contrast are studied. Experimentally, the potential of ECCI is explored in several dislocation configurations in Interstitial-Free steel (Fe - 1% Si) used as a model material. Full interpretations of dislocation contrast in (g, -g) and its evolution along the Kikuchi band are shown. Furthermore, a dislocation dipole is observed and fully characterized for the first time in an SEM.

  17. Phase equilibrium in system Ti-Si-C-B and synthesis of MAX phase layers in vacuum under the influence of electron beam

    Science.gov (United States)

    Smirnyagina, N. N.; Khaltanova, V. M.; Dasheev, D. E.; Lapina, A. E.

    2017-05-01

    Composite layers on the basis of carbides and borides the titan and silicon on titanic alloy VТ-1 are generated at diffused saturation by electron beam treatment in vacuum. Formation in a composite of MAX phase Ti3SiC2 is shown. Thermodynamic research of phase equilibrium in systems Ti-Si-C and Ti-B-C in the conditions of high vacuum is executed. The thermodynamics, formation mechanisms of superfirm layers borides and carbides of the titan and silicon are investigated.

  18. Industrial Robot Automation in Solving Non-Vacuum Electron-Beam Welding Problems

    Directory of Open Access Journals (Sweden)

    Borovik Vasiliy

    2016-01-01

    Full Text Available The paper describes one modeling automated hardware-software system to develop additive technologically - based products. Algorithm synthesis for industrial robot control was performed. In this case, the operating tool is an electron -beam projector with plasma emitter. The model testing results of thermal processes (in 3D-enqueuing proceeding within additive substrate material system have been described. The modeling results revealed those required parameters of emission power which would provide the melting of additive material (TiC excluding boiling.

  19. Pressure Model for the Vacuum System for the Electron Gun and Injector for LCLS Final Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Tung, L S; Eriksson, L

    2006-04-28

    The vacuum system of the injector for the Linac Coherent Light Source (LCLS) has been analyzed and configured by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. The vacuum system layout and detailed analyses for the injector are presented in this final design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated.

  20. Atomic Imaging Using Secondary Electrons in a Scanning Transmission Electron Microscope: Experimental Observations and Possible Mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Su, D.; Inada, H.; Egerton, R.F.; Konno, M.; Wua, L.; Ciston, J.; Wall, J.; Zhu, Y.

    2011-11-11

    We report detailed investigation of high-resolution imaging using secondaryelectrons (SE) with a sub-nanometer probe in an aberration-corrected transmissionelectron microscope, Hitachi HD2700C. This instrument also allows us to acquire the corresponding annular dark-field (ADF) images both simultaneously and separately. We demonstrate that atomic SE imaging is achievable for a wide range of elements, from uranium to carbon. Using the ADF images as a reference, we studied the SE image intensity and contrast as functions of applied bias, atomic number, crystal tilt, and thickness to shed light on the origin of the unexpected ultrahigh resolution in SE imaging. We have also demonstrated that the SE signal is sensitive to the terminating species at a crystal surface. Apossiblemechanism for atomic-scale SE imaging is proposed. The ability to image both the surface and bulk of a sample at atomic-scale is unprecedented, and can have important applications in the field of electron microscopy and materials characterization.

  1. Telocytes and putative stem cells in the lungs: electron microscopy, electron tomography and laser scanning microscopy.

    Science.gov (United States)

    Popescu, Laurentiu M; Gherghiceanu, Mihaela; Suciu, Laura C; Manole, Catalin G; Hinescu, Mihail E

    2011-09-01

    This study describes a novel type of interstitial (stromal) cell - telocytes (TCs) - in the human and mouse respiratory tree (terminal and respiratory bronchioles, as well as alveolar ducts). TCs have recently been described in pleura, epicardium, myocardium, endocardium, intestine, uterus, pancreas, mammary gland, etc. (see www.telocytes.com ). TCs are cells with specific prolongations called telopodes (Tp), frequently two to three per cell. Tp are very long prolongations (tens up to hundreds of μm) built of alternating thin segments known as podomers (≤ 200 nm, below the resolving power of light microscope) and dilated segments called podoms, which accommodate mitochondria, rough endoplasmic reticulum and caveolae. Tp ramify dichotomously, making a 3-dimensional network with complex homo- and heterocellular junctions. Confocal microscopy reveals that TCs are c-kit- and CD34-positive. Tp release shed vesicles or exosomes, sending macromolecular signals to neighboring cells and eventually modifying their transcriptional activity. At bronchoalveolar junctions, TCs have been observed in close association with putative stem cells (SCs) in the subepithelial stroma. SCs are recognized by their ultrastructure and Sca-1 positivity. Tp surround SCs, forming complex TC-SC niches (TC-SCNs). Electron tomography allows the identification of bridging nanostructures, which connect Tp with SCs. In conclusion, this study shows the presence of TCs in lungs and identifies a TC-SC tandem in subepithelial niches of the bronchiolar tree. In TC-SCNs, the synergy of TCs and SCs may be based on nanocontacts and shed vesicles.

  2. Justifying the Vacuum as an Electron-Positron Aggregation and Experimental Falsification

    Science.gov (United States)

    Guy Grantham, R.; Montgomery, Ian G.

    2013-09-01

    Historical aether models are placed in context with the electron-positron lattice (epola) model of space due to M. Simhony. A brief outline of the model as an aggregation state of matter, intermediate to the nuclear state and the atomic aggregation state, includes reference to its derivation of physical laws and fundamental constants. The broad application of the epola model is appraised for its validation against a range of physical laws, experiments and constants. Simhony declared a specific dependence for the stability of atomic matter upon speed through the epola, suggesting a test for falsification. This theme is further developed by the same logic to suggest practical experimental and theoretical tests of the epola model. A formula for the inverse fine structure constant of space, providing the accepted CODATA value, is derived from Simhony's explanation of the Bohr - de Broglie model of the ground state electron orbital of the hydrogen atom by including a term for speed through the Cosmos. A theoretical solution of the Michelson-Morley experiment is applied as evidence for the concept. The mechanism of motion through the epola is considered further for possible implications of speed including dependency of decay rates by radio nuclides and the results of former and ongoing experiments are considered.

  3. Examination of mycological samples by means of the scanning electron microscope

    Directory of Open Access Journals (Sweden)

    M. Thibaut

    1973-04-01

    Full Text Available Three species of Siphomycetes: Rhizopus arhizus, Rhizopus equinus and Rhizopus nigricans, as well as a Septomycete: Emericella nidulans, have been examined by means of a scanning electron microscope. Among the difjerent Rhizopus, this technique showed differences in the appearance of the sporangia. In Emericella nidulans, scanning microscopy enábled one to ascertain that the "Hull cells" were completely hollow and also demonstrated the ornemented aspect of the ascospores.Três espécies de Sifomicetas: Rhizopus arhizus, Rhizopus equinus, Rhizopus nigricans e um Septomiceta: Emericella nidulans foram examinados em microscopia de exploração. Esta técnica mostrou detalhes não evidenciáveis ao poder de resolução do microscópio óptico, demonstrando ser útil para o diagnóstico em micologia.

  4. Electronic structure of carbon nanotube systems measured with scanning tunneling microscopy

    Science.gov (United States)

    Hornbaker, Daniel Jay

    Carbon fullerenes are unusually structured molecules with robust mechanical and electronic properties. Their versatility is astounding; envisioned applications range from field emission displays to impregnated metal composites, battery storage media, and nanoelectronic devices. The combination of simple constituency, diverse behavior, and ease of fabrication makes these materials a cornerstone topic in current research. This thesis details scanning tunneling microscopy (STM) experiments investigating how carbon nanotube fullerenes interact with and couple to their local environment. Scanning tunneling microscopy continues to be a key method for characterizing fullerenes, particularly in regards to their electronic properties. The atomic scale nature of this technique makes it uniquely suited for observing individual molecules and determining correlations between locally measured electronic properties and the particular environment of the molecule. The primary subject of this study is single-wall carbon nanotubes (SWNTs), which were observed under various perturbative influences resulting in measurable changes in the electronic structure. Additionally, fullerene heterostructures formed by the encapsulation of C60 molecules within the hollow interiors of SWNTs were characterized for the first time with STM. These novel macromolecules (dubbed "peapods") demonstrate the potential for custom engineering the properties of fullerene materials. Measurements indicate that the properties of individual nanotubes depend sensitively on local interactions. In particular, pronounced changes in electronic behavior are observed in nanotubes exhibiting mechanical distortion, interacting with extrinsic materials (including other nanotubes), and possessing intrinsic defects in the atomic lattice. In fullerene peapods, while no discernable change in the atomic ordering of the encapsulating nanotubes was evident, the presence of interior C60 molecules has a dramatic effect on the

  5. Angle selective backscattered electron contrast in the low-voltage scanning electron microscope: Simulation and experiment for polymers

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Q., E-mail: qwan2@sheffield.ac.uk [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Masters, R.C. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Lidzey, D. [Department of Physics and Astronomy, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Abrams, K.J. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Dapor, M. [European Centre for Theoretical Studies in Nuclear Physics and Related Areas (ECT-FBK) and Trento Institute for Fundamental Physics and Applications (TIFPA-INFN), via Sommarive 18, I-38123 Trento (Italy); Plenderleith, R.A. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Rimmer, S. [Department of Chemistry, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Claeyssens, F.; Rodenburg, C. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom)

    2016-12-15

    Recently developed detectors can deliver high resolution and high contrast images of nanostructured carbon based materials in low voltage scanning electron microscopes (LVSEM) with beam deceleration. Monte Carlo Simulations are also used to predict under which exact imaging conditions purely compositional contrast can be obtained and optimised. This allows the prediction of the electron signal intensity in angle selective conditions for back-scattered electron (BSE) imaging in LVSEM and compares it to experimental signals. Angle selective detection with a concentric back scattered (CBS) detector is considered in the model in the absence and presence of a deceleration field, respectively. The validity of the model prediction for both cases was tested experimentally for amorphous C and Cu and applied to complex nanostructured carbon based materials, namely a Poly(N-isopropylacrylamide)/Poly(ethylene glycol) Diacrylate (PNIPAM/PEGDA) semi-interpenetration network (IPN) and a Poly(3-hexylthiophene-2,5-diyl) (P3HT) film, to map nano-scale composition and crystallinity distribution by avoiding experimental imaging conditions that lead to a mixed topographical and compositional contrast - Highlights: • An optimised model for nano-scale analysis of beam sensitive materials by LVSEM. • Simulation and separation of composition and topography in a CBS detector. • Selective angle backscattered electron collection for mapping of polymers.

  6. Fibrous architecture of cementodentinal junction in disease: A scanning electron microscopic study.

    Science.gov (United States)

    Sudhakar, R; Pratebha, B

    2015-01-01

    The cementodentinal junction (CDJ) forms a biological and structural link between cementum and dentin. This biological link is regarded as a distinct tissue in its own right. Certain important proteins responsible for periodontal regeneration are said to be present in this tissue. Few studies have described the structure and composition of this layer by light and electron microscopy. Scanning electron microscopic studies pertaining to CDJ in health and disease are few and documentation of periodontal pathological changes of CDJ is unclear. In the first phase of our study, the collagenous architecture of CDJ of healthy teeth has been reported. The objective of this study is to observe and report periodontal pathological changes in the fibrous or collagenous architecture of CDJ of periodontitis-affected teeth and discuss the probable clinical implications of CDJ in disease. Twenty periodontitis-affected teeth were collected and processed for observing under a scanning electron microscope. The results are as follows: Increased width of interface at CDJ in periodontitis samples (7.1 μ) compared to that of healthy samples; fewer areas of fiber intermingling at CDJ in periodontitis samples as compared to healthy samples; frequent detachment of cementum from dentin during sodium hydroxide maceration of samples. It may be inferred from results that there is a possibility of a definite weakening of CDJ in periodontally affected root surfaces and we believe that clinical procedures such as scaling and root planning may have a detrimental effect on the cementodentinal attachment of periodontally involved root surfaces.

  7. A streaming multi-GPU implementation of image simulation algorithms for scanning transmission electron microscopy.

    Science.gov (United States)

    Pryor, Alan; Ophus, Colin; Miao, Jianwei

    2017-01-01

    Simulation of atomic-resolution image formation in scanning transmission electron microscopy can require significant computation times using traditional methods. A recently developed method, termed plane-wave reciprocal-space interpolated scattering matrix (PRISM), demonstrates potential for significant acceleration of such simulations with negligible loss of accuracy. Here, we present a software package called Prismatic for parallelized simulation of image formation in scanning transmission electron microscopy (STEM) using both the PRISM and multislice methods. By distributing the workload between multiple CUDA-enabled GPUs and multicore processors, accelerations as high as 1000 × for PRISM and 15 × for multislice are achieved relative to traditional multislice implementations using a single 4-GPU machine. We demonstrate a potentially important application of Prismatic, using it to compute images for atomic electron tomography at sufficient speeds to include in the reconstruction pipeline. Prismatic is freely available both as an open-source CUDA/C++ package with a graphical user interface and as a Python package, PyPrismatic.

  8. Scanning electron microscopy study of adhesion in sea urchin blastulae. M.S. Thesis

    Science.gov (United States)

    Crowther, Susan D.

    1988-01-01

    The dissociation supernatant (DS) isolated by disaggregating Strongylocentrotus purpuratus blastulae in calcium- and magnesium-free seawater specifically promotes reaggregation of S. purpuratus blastula cells. The purpose of this study was to use scanning electron microscopy to examine the gross morphology of aggregates formed in the presence of DS to see if it resembles adhesion in partially dissociated blastulae. A new reaggregation procedure developed here, using large volumes of cell suspension and a large diameter of rotation, was utilized to obtain sufficient quantities of aggregates for scanning electron microscopy. The results indicate that aggregates formed in the presence of DS resemble partially dissociated intact embryos in terms of the direct cell-cell adhesion observed. DS did not cause aggregation to form as a result of the entrapment of cells in masses of extracellular material. These studies provide the groundwork for further studies using transmission electron microscopy to more precisely define the adhesive contacts made by cells in the presence of the putative adhesion molecules present in DS.

  9. Rapid imaging of mycoplasma in solution using Atmospheric Scanning Electron Microscopy (ASEM)

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Chikara, E-mail: ti-sato@aist.go.jp [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Manaka, Sachie [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Nakane, Daisuke [Department of Biology, Graduate School of Science, Osaka City University, Sumiyoshi-ku, Osaka 558-8585 (Japan); Nishiyama, Hidetoshi; Suga, Mitsuo [Advanced Technology Division, JEOL Ltd., Akishima, Tokyo 196-8558 (Japan); Nishizaka, Takayuki [Department of Physics, Faculty of Science, Gakushuin University, 1-5-1 Mejiro, Toshima-ku, Tokyo 171-8588 (Japan); Miyata, Makoto [Department of Biology, Graduate School of Science, Osaka City University, Sumiyoshi-ku, Osaka 558-8585 (Japan); Maruyama, Yuusuke [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan)

    2012-01-27

    Highlights: Black-Right-Pointing-Pointer Mycoplasma mobile was observed in buffer with the Atmospheric Scanning Electron Microscope. Black-Right-Pointing-Pointer Characteristic protein localizations were visualized using immuno-labeling. Black-Right-Pointing-Pointer M. mobile attached to sialic acid on the SiN film surface within minutes. Black-Right-Pointing-Pointer Cells were observed at low concentrations. Black-Right-Pointing-Pointer ASEM should promote study and early-stage diagnosis of mycoplasma. -- Abstract: Mycoplasma is a genus of bacterial pathogen that causes disease in vertebrates. In humans, the species Mycoplasma pneumoniae causes 15% or more of community-acquired pneumonia. Because this bacterium is tiny, corresponding in size to a large virus, diagnosis using optical microscopy is not easy. In current methods, chest X-rays are usually the first action, followed by serology, PCR amplification, and/or culture, but all of these are particularly difficult at an early stage of the disease. Using Mycoplasma mobile as a model species, we directly observed mycoplasma in buffer with the newly developed Atmospheric Scanning Electron Microscope (ASEM). This microscope features an open sample dish with a pressure-resistant thin film window in its base, through which the SEM beam scans samples in solution, from below. Because of its 2-3 {mu}m-deep scanning capability, it can observe the whole internal structure of mycoplasma cells stained with metal solutions. Characteristic protein localizations were visualized using immuno-labeling. Cells were observed at low concentrations, because suspended cells concentrate in the observable zone by attaching to sialic acid on the silicon nitride (SiN) film surface within minutes. These results suggest the applicability of the ASEM for the study of mycoplasmas as well as for early-stage mycoplasma infection diagnosis.

  10. Thermal Processing of Semiconductor Materials Using Soft-Vacuum Electron Beams.

    Science.gov (United States)

    Moore, Cameron Alden

    Electron beams generated in gaseous discharges have been used to perform a variety of thermal treatments germane to semiconductor fabrication. The unique beams employed in these studies are typified by high continuous power (>100 watts per cm^2 of cathode surface), operation in relatively high pressures (0.05-25 Torr), and a wide variety of beam configurations. The ability to extract and direct high power densities lends itself to the heat treatment of silicon-based semiconductor materials. Initial studies examined the rapid thermal processing of various materials and structures using a 7.5 cm. diameter electron beam. Using this source both the annealing of ion implanted single crystal silicon and the formation of titanium disilicide were performed. The repair of damage in single-crystal silicon wafers induced by ions of boron, phosphorus, and arsenic was repaired with minimum redistribution of the dopant profile. The same apparatus was also used to form titanium silicide from both co-deposited and sequentially deposited constituent materials. While low resistivity phases of both materials were obtained, each would exhibit high resistivity behavior as well. Excessive heating of co-deposited films on silicon dioxide induces reactions between the two films, causing oxygen to be incorporated in the silicide. Ti-on-Si structures self-cleanse oxygen from the silicide during formation, in contradiction to known Si-O and Ti-O thermodynamics. A line-source (150 mm x 2 mm) electron beam was used to recrystallize silicon films deposited on oxidized silicon wafers up to 100 mm in diameter. Agglomeration of the silicon while molten was prevented via the use of (i) an encapsulating silicon dioxide film, and (ii) the introduction of appropriate wetting agents into the deposited silicon during wafer preparation. A limiting constraint to the recrystallization of full wafers was the construction of a background heater which can heat the wafer to 1200 ^circC with a uniformity of

  11. Dose-rate-dependent damage of cerium dioxide in the scanning transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Johnston-Peck, Aaron C., E-mail: aaron.johnston-peck@nist.gov [Materials Measurement Lab, National Institute of Standards Technology, Gaithersburg, MD 20899 (United States); DuChene, Joseph S.; Roberts, Alan D.; Wei, Wei David [Department of Chemistry and Center for Nanostructured Electronic Materials, University of Florida, Gainesville, FL 32611 (United States); Herzing, Andrew A. [Materials Measurement Lab, National Institute of Standards Technology, Gaithersburg, MD 20899 (United States)

    2016-11-15

    Beam damage caused by energetic electrons in the transmission electron microscope is a fundamental constraint limiting the collection of artifact-free information. Through understanding the influence of the electron beam, experimental routines may be adjusted to improve the data collection process. Investigations of CeO{sub 2} indicate that there is not a critical dose required for the accumulation of electron beam damage. Instead, measurements using annular dark field scanning transmission electron microscopy and electron energy loss spectroscopy demonstrate that the onset of measurable damage occurs when a critical dose rate is exceeded. The mechanism behind this phenomenon is that oxygen vacancies created by exposure to a 300 keV electron beam are actively annihilated as the sample re-oxidizes in the microscope environment. As a result, only when the rate of vacancy creation exceeds the recovery rate will beam damage begin to accumulate. This observation suggests that dose-intensive experiments can be accomplished without disrupting the native structure of the sample when executed using dose rates below the appropriate threshold. Furthermore, the presence of an encapsulating carbonaceous layer inhibits processes that cause beam damage, markedly increasing the dose rate threshold for the accumulation of damage. - Highlights: • Electron beam interactions introduce oxygen vacancies in CeO{sub 2} nanoparticles. • ADF-STEM and EELS can track the reduction of CeO{sub 2}. • The reduced nanoparticles will oxidize in the microscope environment. • There is no critical dose for the accumulation of detectable damage. • The accumulation of detectable damage is dose rate dependent.

  12. Target, purging magnet and electron collector design for scanned high-energy photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Roger; Aasell, Mats; Naefstadius, Peder; Brahme, Anders [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, PO Box 260, S-171 76 Stockholm (Sweden)

    1998-05-01

    A new method for producing very narrow and intense 50 MV bremsstrahlung beams with a half-width as low as 35 mm at a distance of 1 m from the target is presented. Such a beam is well suited for intensity modulation using scanned photon beams. An algorithm has been developed to minimize the width of the bremsstrahlung beam generated in a multilayer target by varying the individual layer thicknesses and atomic numbers under given constraints on the total target thickness and the mean energy of the transmitted electrons. Under such constraints the narrowest possible bremsstrahlung beam is obtained with a target composed of layers of monotonically increasing atomic number starting with the lowest possible value at the entrance side where the electrons impinge. It is also shown that the narrowest photon beam profile is associated with the highest possible forward photon yield. To be able to use the optimized target clinically it is desirable to be able to collect and stop all the electrons that are transmitted through the target. The electrons are most efficiently collected if they are kept close together, i.e. by minimizing the multiple scatter of the electrons and consequently the half-width of the generated bremsstrahlung beam. This is achieved by a thin low-atomic-number target. A dedicated electron stopper has been developed and integrated with the purging magnet. When the electron stopper is combined with a purging magnet, a primary photon collimator and a multileaf collimator, almost all of the transmitted electrons and their associated bremsstrahlung contamination can effectively be collected. The narrow photon beams from thin low-atomic-number targets have the additional advantage of producing the hardest and most penetrative photon spectrum possible, which is ideal for treating large deep-seated tumours. (author)

  13. A design for a subminiature, low energy scanning electron microscope with atomic resolution

    Science.gov (United States)

    Eastham, D. A.; Edmondson, P.; Greene, S.; Donnelly, S.; Olsson, E.; Svensson, K.; Bleloch, A.

    2009-01-01

    We describe a type of scanning electron microscope that works by directly imaging the electron field-emission sites on a nanotip. Electrons are extracted from the nanotip through a nanoscale aperture, accelerated in a high electric field, and focused to a spot using a microscale Einzel lens. If the whole microscope (accelerating section and lens) and the focal length are both restricted in size to below 10 μm, then computer simulations show that the effects of aberration are extremely small and it is possible to have a system with approximately unit magnification at electron energies as low as 300 eV. Thus a typical emission site of 1 nm diameter will produce an image of the same size, and an atomic emission site will give a resolution of 0.1-0.2 nm (1-2 Å). Also, because the beam is not allowed to expand beyond 100 nm in diameter, the depth of field is large and the contribution to the beam spot size from chromatic aberrations is less than 0.02 nm (0.2 Å) for 500 eV electrons. Since it is now entirely possible to make stable atomic sized emitters (nanopyramids), it is expected that this instrument will have atomic resolution. Furthermore the brightness of the beam is determined only by the field emission and can be up to 1×106 times larger than in a typical (high energy) electron microscope. The advantages of this low energy, bright-beam electron microscope with atomic resolution are described and include the possibility of it being used to rapidly sequence the human genome from a single strand of DNA as well as being able to identify atomic species directly from the elastic scattering of electrons.

  14. Subsurface Examination of a Foliar Biofilm Using Scanning Electron- and Focused-Ion-Beam Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Patricia K.; Arey, Bruce W.; Mahaffee, Walt F.

    2011-08-01

    The dual beam scanning electron microscope, equipped with both a focused ion- and scanning electron- beam (FIB SEM) is a novel tool for the exploration of the subsurface structure of biological tissues. The FIB can remove a predetermined amount of material from a selected site to allow for subsurface exploration and when coupled with SEM or scanning ion- beam microscopy (SIM) could be suitable to examine the subsurface structure of bacterial biofilms on the leaf surface. The suitability of chemical and cryofixation was examined for use with the FIB SEM to examine bacterial biofilms on leaf surfaces. The biological control agent, Burkholderia pyroccinia FP62, that rapidly colonizes the leaf surface and forms biofilms, was inoculated onto geranium leaves and incubated in a greenhouse for 7 or 14 days. Cryofixation was not suitable for examination of leaf biofilms because it created a frozen layer over the leaf surface that cracked when exposed to the electron beam and the protective cap required for FIB milling could not be accurately deposited. With chemically fixed samples, it was possible to precisely FIB mill a single cross section (5 µm) or sequential cross sections from a single site without any damage to the surrounding surface. Biofilms, 7 days post-inoculation (DPI), were composed of 2 to 5 bacterial cell layers while biofilms 14 DPI ranged from 5 to greater than 30 cell layers. Empty spaces between bacteria cells in the subsurface structure were observed in biofilms 7- and 14-DPI. Sequential cross sections inferred that the empty spaces were often continuous between FP62 cells and could possibly make up a network of channels throughout the biofilm. FIB SEM was a useful tool to observe the subsurface composition of a foliar biofilm.

  15. Scanning electron microscopy and X-ray spectroscopy applied to mycelial phase of sporothrix schenckii

    Directory of Open Access Journals (Sweden)

    M. Thibaut

    1975-04-01

    Full Text Available Scanning electron microscopy applied to the mycelial phase of Sporothrix schenckii shows a matted mycelium with conidia of a regular pattern. X-Ray microanalysis applied in energy dispersive spectroscopy and also in wavelength dispersive spectroscopy reveals the presence of several elements of Mendeleef's classification.Sporothrix schenckii foi estudado em microscopia eletrônica. Foram observados caracteres das hífas e dos esporos, vários elementos da classificação periódica foram postos em evidência graças à micro-análise a raios X.

  16. Verifying Data Integrity of Electronically Scanned Pressure Systems at the NASA Glenn Research Center

    Science.gov (United States)

    Panek, Joseph W.

    2001-01-01

    The proper operation of the Electronically Scanned Pressure (ESP) System critical to accomplish the following goals: acquisition of highly accurate pressure data for the development of aerospace and commercial aviation systems and continuous confirmation of data quality to avoid costly, unplanned, repeat wind tunnel or turbine testing. Standard automated setup and checkout routines are necessary to accomplish these goals. Data verification and integrity checks occur at three distinct stages, pretest pressure tubing and system checkouts, daily system validation and in-test confirmation of critical system parameters. This paper will give an overview of the existing hardware, software and methods used to validate data integrity.

  17. Imaging metazoan nuclear pore complexes by field emission scanning electron microscopy.

    Science.gov (United States)

    Fichtman, Boris; Shaulov, Lihi; Harel, Amnon

    2014-01-01

    High resolution three-dimensional surface images of nuclear pore complexes (NPCs) can be obtained by field emission scanning electron microscopy. We present a short retrospective view starting from the early roots of microscopy, through the discovery of the cell nucleus and the development of some modern techniques for sample preparation and imaging. Detailed protocols are presented for assembling anchored nuclei in a Xenopus cell-free reconstitution system and for the exposure of the nuclear surface in mammalian cell nuclei. Immunogold labeling of metazoan NPCs and a promising new technique for delicate coating with iridium are also discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Atomic bonding effects in annular dark field scanning transmission electron microscopy. II. Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Odlyzko, Michael L.; Held, Jacob T.; Mkhoyan, K. Andre, E-mail: mkhoyan@umn.edu [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

    2016-07-15

    Quantitatively calibrated annular dark field scanning transmission electron microscopy (ADF-STEM) imaging experiments were compared to frozen phonon multislice simulations adapted to include chemical bonding effects. Having carefully matched simulation parameters to experimental conditions, a depth-dependent bonding effect was observed for high-angle ADF-STEM imaging of aluminum nitride. This result is explained by computational predictions, systematically examined in the preceding portion of this study, showing the propagation of the converged STEM beam to be highly sensitive to net interatomic charge transfer. Thus, although uncertainties in experimental conditions and simulation accuracy remain, the computationally predicted experimental bonding effect withstands the experimental testing reported here.

  19. Alcoholic liver injury: defenestration in noncirrhotic livers--a scanning electron microscopic study

    DEFF Research Database (Denmark)

    Horn, T; Christoffersen, P; Henriksen, Jens Henrik Sahl

    1987-01-01

    (fractional area of fenestrae) was observed in acinar Zone 3, both in biopsies with and without Zone 3 fibrosis as judged by light microscopy. A significant reduction of porosity as shown in this study may influence the blood hepatocytic exchange and contribute to the alcohol-induced liver injury.......The fenestration of hepatic sinusoidal endothelial cells in 15 needle biopsies obtained from chronic alcoholics without cirrhosis was studied by scanning electron microscopy. As compared to nonalcoholics, a significant reduction in the number of fenestrae and porosity of the sinusoidal lining wall...

  20. Investigation on traceability of 3D Scanning Electron Microscopy based on the Stereo Pair Technique

    DEFF Research Database (Denmark)

    Bariani, Paolo

    The scanning electron microscope (SEM) has a big potential as a metrology instrument for micro and nanotechnology due to its unique combination of three imaging properties: • Lateral ultimate resolution down to 2nm • Large range of possible magnification levels ranging from a few hundred times...... to one hundred thousand times magnification. • Large depth of field. Topography reconstruction with this instrument and stereo photogrammetric techniques has been known for a long time. Nowadays, availability of digital SEMs and the advances in computer technology have made it possible to implement...

  1. Atomic force microscopy and scanning electron microscopy analysis of daily disposable limbal ring contact lenses

    OpenAIRE

    Lorenz, Kathrine Osborn; Kakkassery, Joseph; Boree, Danielle; Pinto, David

    2014-01-01

    Background Limbal ring (also known as ‘circle’) contact lenses are becoming increasingly popular, especially in Asian markets because of their eye-enhancing effects. The pigment particles that give the eye-enhancing effects of these lenses can be found on the front or back surface of the contact lens or ‘enclosed’ within the lens matrix. The purpose of this research was to evaluate the pigment location and surface roughness of seven types of ‘circle’ contact lenses. Methods Scanning electron ...

  2. Compositional analysis of GaAs/AlGaAs heterostructures using quantitative scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kauko, H.; Helvoort, A. T. J. van [Department of Physics, Norwegian University of Science and Technology (NTNU), Trondheim (Norway); Zheng, C. L.; Glanvill, S. [Monash Centre for Electron Microscopy, Monash University, VIC 3800 (Australia); Zhu, Y.; Etheridge, J., E-mail: joanne.etheridge@monash.edu [Monash Centre for Electron Microscopy, Monash University, VIC 3800 (Australia); Department of Materials Engineering, Monash University, VIC 3800 (Australia); Dwyer, C. [Monash Centre for Electron Microscopy, Monash University, VIC 3800 (Australia); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Munshi, A. M.; Fimland, B. O. [Department of Electronics and Telecommunications, Norwegian University of Science and Technology (NTNU), Trondheim (Norway)

    2013-12-02

    We demonstrate a method for compositional mapping of Al{sub x}Ga{sub 1–x}As heterostructures with high accuracy and unit cell spatial resolution using quantitative high angle annular dark field scanning transmission electron microscopy. The method is low dose relative to spectroscopic methods and insensitive to the effective source size and higher order lens aberrations. We apply the method to study the spatial variation in Al concentration in cross-sectioned GaAs/AlGaAs core-shell nanowires and quantify the concentration in the Al-rich radial band and the AlGaAs shell segments.

  3. Metadislocations in complex metallic alloys: A high-resolution scanning transmission electron microscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Heggen, Marc; Houben, Lothar; Feuerbacher, Michael [Ernst Ruska Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Juelich GmbH, D-52425 Juelich (Germany)

    2011-07-01

    Metadislocations are highly complex defects which involve several hundreds of atoms in their core. We present a microstructural investigation on Metadislocations using aberration-corrected high-resolution scanning transmission electron microscopy. A novel and highly complex deformation mechanism is found which is based on the movement of a metadislocation core mediating strain and separate escort defects. Upon deformation, the escort defects move along with the metadislocation core and locally transform the material structure. This mechanism implies the coordinated movement of hundreds of atoms per elementary step. Although the mechanism is very complex, it can be described by a simple jigsaw-puzzle-like rearrangement of basic structural subunits.

  4. [Scanning electron microscopic observations on the copulatory spicules of the male Necator americanus and Ancylostoma duodenale].

    Science.gov (United States)

    Xu, S E; Lu, X J; Xie, L C; Zhang, D P

    1993-01-01

    Scanning electron microscopic observations were made on the morphological structures of the two copulatory spicules of the male Necator americanus and Ancylostoma duodenale. In both species, one of the two copulatory spicules was in the shape of a concave groove and the other, in the shape of an oblate tube. Owing to the difference in the concavity of the groove shaped copulatory spicule between the two species as shown by the cross sections, Necator americanus usually appear to have only one copulatory spicule whereas Ancylostoma duodenale usually show two separate copulatory spicules in appearance (Figs 1-10).

  5. A scanning electron microscopic study of impala (Aepyceros melampus sperm from the Kruger National Park

    Directory of Open Access Journals (Sweden)

    D.J. Ackerman

    1996-02-01

    Full Text Available Since knowledge of sperm morphological characteristics can play an important role in semen evaluation and fertilisation, baseline data on sperm ultrastructure are required. Live spermatozoa were collected from the cauda epididymis from 64 impala rams in the Kruger National Park and 5082 spermatozoa from 40 of these impala were studied by scanning electron microscopy. The mean length of impala sperm was 59.23 @ 2.7 um. The morphology of normal sperm as well as the occurrence of abnormalities were documented. The morphology of impala sperm were compared with those of other mammals. New findings on appendages of the cytoplasmic droplet are described and interpreted.

  6. Calibration of Electrochemical Capacitance-voltage Method on Pyramid Texture Surface Using Scanning Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Komatsu, Y.; Cesar, I. [ECN Solar Energy, P.O.Box 1, 1755ZG Petten (Netherlands); Harata, D. [Department of Electronic Science and Engineering, Kyoto University, Nishikyo-ku, Kyoto 615-8530 (Japan); Schuring, E.W. [ECN Environment and Energy Engineering, P.O.Box 1, 1755ZG Petten (Netherlands); Vlooswijk, A.H.G.; Venema, P.R. [Tempress Systems BV, Radeweg 31, 8171MD Vaassen (Netherlands); Katori, S.; Fujita, S. [Photonics and Electronics Science and Engineering Center, Kyoto University, Nishikyo-ku, Kyoto 615-8530 (Japan)

    2013-07-01

    The electrochemical capacitance-voltage (ECV) technique can practically profile carrier concentrations on textured surfaces, but reliable calibration of the surface area is strongly demanded since it plays a decisive role in calculating both the carrier concentration and the profiling depth. In this work, we calibrate the area factor of pyramidally textured surfaces by comparing ECV profiles with cross-sectional scanning electron microscopy image, and found out it is 1.66, and not 1.73 which was formerly assumed. Furthermore, the calibrated area factor was applied to POCl3 and BBr3 diffusions which resulted in comparable diffusion profiles for both textured and polished surfaces.

  7. Unveiling the Mysteries of Mars with a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM)

    Science.gov (United States)

    Edmunson, J.; Gaskin, J. A.; Doloboff, I. J.; Jerman, G.

    2017-01-01

    Development of a miniaturized scanning electron microscope that will utilize the martian atmosphere to dissipate charge during analysis continues. This instrument is expected to be used on a future rover or lander to answer fundamental Mars science questions. To identify the most important questions, a survey was taken at the 47th Lunar and Planetary Science Conference (LPSC). From the gathered information initial topics were identified for a SEM on the martian surface. These priorities are identified and discussed below. Additionally, a concept of operations is provided with the goal of maximizing the science obtained with the minimum amount of communication with the instrument.

  8. Scanning electron microscopic analyses of Ferrocyanide tank wastes for the Ferrocyanide safety program

    Energy Technology Data Exchange (ETDEWEB)

    Callaway, W.S.

    1995-09-01

    This is Fiscal Year 1995 Annual Report on the progress of activities relating to the application of scanning electron microscopy in addressing the Ferrocyanide Safety Issue associated with Hanford Site high-level radioactive waste tanks. The status of the FY 1995 activities directed towards establishing facilities capable of providing SEM based micro-characterization of ferrocyanide tank wastes is described. A summary of key events in the SEM task over FY 1995 and target activities in FY 1996 are presented. A brief overview of the potential applications of computer controlled SEM analytical data in light of analyses of ferrocyanide simulants performed by an independent contractor is also presented

  9. Observations on mouthparts of Dermatobia hominis (Linneaus Jr., 1781) (Diptera: Cuterebridae) by scanning electron microscopy.

    Science.gov (United States)

    Fernandes, Fernando de Freitas; Linardi, Pedro Marcos

    2002-02-01

    The ultrastructure of the mouthparts of Dermatobia hominis was studied using scanning electron microscopy. The morphological characteristics of the segments, articulations, sensory organs, and pilose covering are described. Mechanoreceptors of the long trichoid sensillum and smaller trichoid sensillum types were observed, as well as labellar gustatory receptors of the basiconic sensillum type, which differed between the sexes. These observations are discussed with reference to the current literature on the morphology and sense organs of dipteran mouthparts, and the prevailing view that the adult mouthparts of this species are non-functional is challenged.

  10. Scanning electron microscopy of the egg and the first instar larva of Dermatobia hominis (Diptera, cuterebridae

    Directory of Open Access Journals (Sweden)

    Antonio Cesar Rios Leite

    1988-06-01

    Full Text Available The egg and the first instar larva of Dermatobia hominis were described based on observation with a scanning electron microscope.O ovo e a larva de primeiro estágio de Dermatobia hominis são descritos baseados em observações com um microscópio eletrônico de varredura. Comparações morfológicas são feitas com outras espécies de Diptera, particularmente com Cuterebridae.

  11. PRISMLESS ENAMEL IN HUMAN NON-ERUPTED DECIDUOUS MOLAR TEETH: A SCANNING ELECTRON MICROSCOPIC STUDY

    Directory of Open Access Journals (Sweden)

    FAVA Marcelo

    1997-01-01

    Full Text Available The frequency, structure and thickness of the prismless enamel layer in the buccal and lingual surfaces of non-erupted deciduous molar teeth were described. The teeth were extracted, kept in a 70% ethanol solution, dried, coated with gold and examined in a scanning electron microscope JEOL, JSM-6.100. The aprismatic layer was observed in the occlusal, middle and cervical thirds of all buccal and lingual surfaces. The hydroxyapatite crystals were arranged parallel to each other and perpendicular to the enamel surface. No statistically significant differences were observed between the occlusal, middle and cervical thirds, which had 7.257 m m of average thickness.

  12. Scanning electron microscopy of the collodion membrane from a self-healing collodion baby*

    Science.gov (United States)

    de Almeida Jr., Hiram Larangeira; Isaacsson, Henrique; Guarenti, Isabelle Maffei; Silva, Ricardo Marques e; de Castro, Luis Antônio Suita

    2015-01-01

    Abstract Self-healing collodion baby is a well-established subtype of this condition. We examined a male newborn, who was covered by a collodion membrane. The shed membrane was examined with scanning electron microscopy. The outer surface showed a very compact keratin without the normal elimination of corneocytes. The lateral view of the specimen revealed a very thick, horny layer. The inner surface showed the structure of lower corneocytes with polygonal contour. With higher magnifications villous projections were seen in the cell membrane. PMID:26375232

  13. Manipulation of nanoparticles of different shapes inside a scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Boris Polyakov

    2014-02-01

    Full Text Available In this work polyhedron-like gold and sphere-like silver nanoparticles (NPs were manipulated on an oxidized Si substrate to study the dependence of the static friction and the contact area on the particle geometry. Measurements were performed inside a scanning electron microscope (SEM that was equipped with a high-precision XYZ-nanomanipulator. To register the occurring forces a quartz tuning fork (QTF with a glued sharp probe was used. Contact areas and static friction forces were calculated by using different models and compared with the experimentally measured force. The effect of NP morphology on the nanoscale friction is discussed.

  14. Scanning electron microscopic study of hamster tracheal organ cultures infected with Bordetella pertussis.

    Science.gov (United States)

    Muse, K E; Collier, A M; Baseman, J B

    1977-12-01

    Hamster tracheal organculture was employed as a model for the study of the pathogenesis of infection due to bordetella pertusis. Scanning electron microscopy provided a three-dimensional view of the surface infection of the tracheal explants. Phase I B. pertussis attached only to the ciliated epithelial cells, and a sequence of events involving the injury, expulsion, and destruction of these differentiated cells occurred. This in vitro model provides insights into the mechanisms by which B. pertussis mediates host cell injury at the site of infection.

  15. Fatal poisoning by Rumex crispus (curled dock): pathological findings and application of scanning electron microscopy.

    Science.gov (United States)

    Reig, R; Sanz, P; Blanche, C; Fontarnau, R; Dominguez, A; Corbella, J

    1990-10-01

    A case of fatal poisoning due to ingestion of the plant Rumex crispus (curled dock) is described. The patient, a 53-year-old male, presented with gastrointestinal symptoms, severe hypocalcemia, metabolic acidosis and acute hepatic insufficiency. Despite therapeutic measures, the patient died 72 h after ingestion of the plant material. Noteworthy among the pathological findings were centrolobular hepatic necrosis and birefringent crystals in the liver and kidneys that were identified by histochemical techniques and scanning electron microscopy. These observations are compared with other reports in the medical literature, with an emphasis on the risk involved in the use of these plants for culinary or medicinal purposes.

  16. Scanning electron observation of protective effect of graphene films on Au nanoparticles

    Science.gov (United States)

    Kim, Jun Woo; An, Jin Yong; Ahn, Sang Jung; Kahng, Yung Ho

    2017-08-01

    Based on recent developments in nanotechnology, many interesting functions are expected to be performed by nanoscale structures in the future. With these expectations comes the realization that these delicate structures must be protected without interfering with their function. In the study reported here, we studied the protective effects of reduced and non-reduced graphene oxide films on Au nanoparticles deposited on a substrate surface as a type of nanoscale structure. The results indicate that the graphene films can function as a protective layer for the nanoparticles without interfering in their observations by scanning electron microscopy. Our results demonstrate the possibility of using graphene as a protective film for nanoscale structures.

  17. Experimental and theoretical studies of vacuum-ultraviolet electronic circular dichroism of hydroxy acids in aqueous solution.

    Science.gov (United States)

    Fukuyama, Takayuki; Matsuo, Koichi; Gekko, Kunihiko

    2011-01-01

    The electronic circular dichroism (ECD) spectra of three L-hydroxy acids (L-lactic acid, (+)-(S)-2-hydroxy-3-methylbutyric acid, and (-)-(S)-2-hydroxyisocaproic acid) were measured down to 160 nm in aqueous solution using a vacuum-ultraviolet ECD spectrophotometer. To assign the two positive peaks around 210 and 175 nm and the one negative peak around 190 nm in the observed spectra, the ECD spectrum of L-lactic acid was calculated using time-dependent density functional theory (DFT) for the optimized structures by DFT and a continuum model. The observed ECD spectrum was successfully reproduced as the average spectrum for four optimized structures with seven water molecules that localized around the COO(-) and OH groups of L-lactic acid. The positive peak around 210 nm and the negative peak around 185 nm in the calculated spectrum were attributable to the nπ* transition of the carboxyl group, with the latter peak also being influenced by the ππ* transition of the carboxyl group; however, the positive peak around 165 nm involved unassignable higher energy transitions. The comparison of the calculated ECD spectra for L-lactic acid and L-alanine revealed that the network with loose hydrogen bonding around the COO(-) and OH groups is responsible for the flexible conformation of hydroxy acids and complicated side-chain dependence of ECD spectra relative to amino acids. Copyright © 2011 Wiley Periodicals, Inc.

  18. Experimental Evaluation and Comparison of Thermal Conductivity of High-Voltage Insulation Materials for Vacuum Electronic Devices

    Science.gov (United States)

    Suresh, C.; Srikrishna, P.

    2017-07-01

    Vacuum electronic devices operate with very high voltage differences between their sub-assemblies which are separated by very small distances. These devices also emit large amounts of heat that needs to be dissipated. Hence, there exists a requirement for high-voltage insulators with good thermal conductivity for voltage isolation and efficient heat dissipation. However, these voltage insulators are generally poor conductors of heat. In the present work, an effort has been made to obtain good high-voltage insulation materials with substantial improvement in their thermal conductivity. New mixtures of composites were formed by blending varying percentages (by volumes) of aluminum nitride powders with that of neat room-temperature vulcanizing (RTV) silicone elastomer compound. In this work, a thermal conductivity test setup has been devised for the quantification of the thermal conductivity of the insulators. The thermal conductivities and high-voltage isolation capabilities of various blended composites were quantified and were compared with that of neat RTV to evaluate the relative improvement.

  19. Clinical applications of scanning electron microscopy and X-ray microanalysis in dermatology

    Energy Technology Data Exchange (ETDEWEB)

    Forslind, B.

    1984-01-01

    Scanning electron microscopy is frequently applied to dermatological problems, as is evident from a review of the recent literature. In this paper, preparation methods and new techniques allowing experimental studies on the integumentary system are emphasized. Quantitative analysis in the electron microscope by use of energy-dispersive X-ray microanalysis (EDX) has become an important accessory technique. EDX can, for instance, be used to study problems involving physiological changes induced in skin by agents causing contact reactions. Recently, it has been shown that treatment with DNCB, chromate and nickel causes changes in elemental distribution in guinea-pig skin. In addition, elemental uptake in the integumentary system and in pathological inclusions in skin can be analyzed.

  20. Placing single atoms in graphene with a scanning transmission electron microscope

    Science.gov (United States)

    Dyck, Ondrej; Kim, Songkil; Kalinin, Sergei V.; Jesse, Stephen

    2017-09-01

    We employ the sub-atomically focused beam of a scanning transmission electron microscope (STEM) to introduce and controllably manipulate individual dopant atoms in a 2D graphene lattice. The electron beam is used to create defects and subsequently sputter adsorbed source materials into the graphene lattice such that individual vacancy defects are controllably passivated by Si substitutional atoms. We further document that Si point defects may be directed through the lattice via e-beam control or modified (as yet, uncontrollably) to form new defects which can incorporate new atoms into the graphene lattice. These studies demonstrate the potential of STEM for atom-by-atom nanofabrication and fundamental studies of chemical reactions in 2D materials on the atomic level.

  1. Annular dark-field scanning transmission electron microscopy (ADF-STEM) tomography of polymer systems.

    Science.gov (United States)

    Lu, Kangbo; Sourty, Erwan; Loos, Joachim

    2010-08-01

    We have utilized bright-field conventional transmission electron microscopy tomography and annular dark-field scanning transmission electron microscopy (ADF-STEM) tomography to characterize a well-defined carbon black (CB)-filled polymer nanocomposite with known CB volume concentration. For both imaging methods, contrast can be generated between the CB and the surrounding polymer matrix. The involved contrast mechanisms, in particular for ADF-STEM, will be discussed in detail. The obtained volume reconstructions were analysed and the CB volume concentrations were carefully determined from the reconstructed data. For both imaging modes, the measured CB volume concentrations are substantially different and only quantification based on the ADF-STEM data revealed about the same value as the known CB loading. Moreover, when applying low-convergence angles for imaging ADF-STEM tomography, data can be obtained of micrometre-thick samples.

  2. Atomic bonding effects in annular dark field scanning transmission electron microscopy. I. Computational predictions

    Energy Technology Data Exchange (ETDEWEB)

    Odlyzko, Michael L.; Mkhoyan, K. Andre, E-mail: mkhoyan@umn.edu [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455 (United States); Himmetoglu, Burak [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455 and Materials Department, University of California, Santa Barbara, California 93106 (United States); Cococcioni, Matteo [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455 and Theory and Simulations of Materials, National Centre for Computational Design and Discovery of Novel Materials, École polytechnique fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland)

    2016-07-15

    Annular dark field scanning transmission electron microscopy (ADF-STEM) image simulations were performed for zone-axis-oriented light-element single crystals, using a multislice method adapted to include charge redistribution due to chemical bonding. Examination of these image simulations alongside calculations of the propagation of the focused electron probe reveal that the evolution of the probe intensity with thickness exhibits significant sensitivity to interatomic charge transfer, accounting for observed thickness-dependent bonding sensitivity of contrast in all ADF-STEM imaging conditions. Because changes in image contrast relative to conventional neutral atom simulations scale directly with the net interatomic charge transfer, the strongest effects are seen in crystals with highly polar bonding, while no effects are seen for nonpolar bonding. Although the bonding dependence of ADF-STEM image contrast varies with detector geometry, imaging parameters, and material temperature, these simulations predict the bonding effects to be experimentally measureable.

  3. In situ study of live specimens in an environmental scanning electron microscope.

    Science.gov (United States)

    Tihlaříková, Eva; Neděla, Vilém; Shiojiri, Makoto

    2013-08-01

    In this paper we introduce new methodology for the observation of living biological samples in an environmental scanning electron microscope (ESEM). The methodology is based on an unconventional initiation procedure for ESEM chamber pumping, free from purge-flood cycles, and on the ability to control thermodynamic processes close to the sample. The gradual and gentle change of the working environment from air to water vapor enables the study of not only living samples in dynamic in situ experiments and their manifestation of life (sample walking) but also its experimentally stimulated physiological reactions. Moreover, Monte Carlo simulations of primary electron beam energy losses in a water layer on the sample surface were studied; consequently, the influence of the water thickness on radiation, temperature, or chemical damage of the sample was considered.

  4. A comparative scanning electron microscopic view of the integument of domestic mammals.

    Science.gov (United States)

    Meyer, W; Neurand, K

    1987-03-01

    Scanning electron microscopy (SEM) demonstrates efficiently species-specific differences of hairy skin (integumentum commune) of domestic mammals (pig, cat, dog, horse, cattle, sheep, goat). This technique is very helpful in characterizing the typical structural features of the epidermal layers, the arrangement of the collagen fibre bundles and the elastic fibre network in the dermis, the external and internal construction of hair follicles and hair shafts, and the functional development of skin glands. It is also possible to observe certain domestication effects, especially where the hair coat is concerned. SEM supplements the knowledge about the integument as available from conventional transmission electron microscopy, light microscopy or histochemistry. Thus, comparative morphology can be the basis for the development of specific functional models of the different integumentary layers and derivatives or their tissues involved.

  5. Sensitivity Analysis of X-ray Spectra from Scanning Electron Microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas Martin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patton, Bruce W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Weber, Charles F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bekar, Kursat B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-10-01

    The primary goal of this project is to evaluate x-ray spectra generated within a scanning electron microscope (SEM) to determine elemental composition of small samples. This will be accomplished by performing Monte Carlo simulations of the electron and photon interactions in the sample and in the x-ray detector. The elemental inventories will be determined by an inverse process that progressively reduces the difference between the measured and simulated x-ray spectra by iteratively adjusting composition and geometric variables in the computational model. The intended benefit of this work will be to develop a method to perform quantitative analysis on substandard samples (heterogeneous phases, rough surfaces, small sizes, etc.) without involving standard elemental samples or empirical matrix corrections (i.e., true standardless quantitative analysis).

  6. Design of a cathodoluminescence image generator using a Raspberry Pi coupled to a scanning electron microscope.

    Science.gov (United States)

    Benítez, Alfredo; Santiago, Ulises; Sanchez, John E; Ponce, Arturo

    2018-01-01

    In this work, an innovative cathodoluminescence (CL) system is coupled to a scanning electron microscope and synchronized with a Raspberry Pi computer integrated with an innovative processing signal. The post-processing signal is based on a Python algorithm that correlates the CL and secondary electron (SE) images with a precise dwell time correction. For CL imaging, the emission signal is collected through an optical fiber and transduced to an electrical signal via a photomultiplier tube (PMT). CL Images are registered in a panchromatic mode and can be filtered using a monochromator connected between the optical fiber and the PMT to produce monochromatic CL images. The designed system has been employed to study ZnO samples prepared by electrical arc discharge and microwave methods. CL images are compared with SE images and chemical elemental mapping images to correlate the emission regions of the sample.

  7. Design of a cathodoluminescence image generator using a Raspberry Pi coupled to a scanning electron microscope

    Science.gov (United States)

    Benítez, Alfredo; Santiago, Ulises; Sanchez, John E.; Ponce, Arturo

    2018-01-01

    In this work, an innovative cathodoluminescence (CL) system is coupled to a scanning electron microscope and synchronized with a Raspberry Pi computer integrated with an innovative processing signal. The post-processing signal is based on a Python algorithm that correlates the CL and secondary electron (SE) images with a precise dwell time correction. For CL imaging, the emission signal is collected through an optical fiber and transduced to an electrical signal via a photomultiplier tube (PMT). CL Images are registered in a panchromatic mode and can be filtered using a monochromator connected between the optical fiber and the PMT to produce monochromatic CL images. The designed system has been employed to study ZnO samples prepared by electrical arc discharge and microwave methods. CL images are compared with SE images and chemical elemental mapping images to correlate the emission regions of the sample.

  8. Electron transport parameters in CO$_2$: scanning drift tube measurements and kinetic computations

    CERN Document Server

    Vass, M; Loffhagen, D; Pinhao, N; Donko, Z

    2016-01-01

    This work presents transport coefficients of electrons (bulk drift velocity, longitudinal diffusion coefficient, and effective ionization frequency) in CO2 measured under time-of-flight conditions over a wide range of the reduced electric field, 15Td <= E/N <= 2660Td in a scanning drift tube apparatus. The data obtained in the experiments are also applied to determine the effective steady-state Townsend ionization coefficient. These parameters are compared to the results of previous experimental studies, as well as to results of various kinetic computations: solutions of the electron Boltzmann equation under different approximations (multiterm and density gradient expansions) and Monte Carlo simulations. The experimental data extend the range of E/N compared with previous measurements and are consistent with most of the transport parameters obtained in these earlier studies. The computational results point out the range of applicability of the respective approaches to determine the different measured tr...

  9. Field emission scanning electron microscopy (FE-SEM) as an approach for nanoparticle detection inside cells.

    Science.gov (United States)

    Havrdova, M; Polakova, K; Skopalik, J; Vujtek, M; Mokdad, A; Homolkova, M; Tucek, J; Nebesarova, J; Zboril, R

    2014-12-01

    When developing new nanoparticles for bio-applications, it is important to fully characterize the nanoparticle's behavior in biological systems. The most common techniques employed for mapping nanoparticles inside cells include transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM). These techniques entail passing an electron beam through a thin specimen. STEM or TEM imaging is often used for the detection of nanoparticles inside cellular organelles. However, lengthy sample preparation is required (i.e., fixation, dehydration, drying, resin embedding, and cutting). In the present work, a new matrix (FTO glass) for biological samples was used and characterized by field emission scanning electron microscopy (FE-SEM) to generate images comparable to those obtained by TEM. Using FE-SEM, nanoparticle images were acquired inside endo/lysosomes without disruption of the cellular shape. Furthermore, the initial steps of nanoparticle incorporation into the cells were captured. In addition, the conductive FTO glass endowed the sample with high stability under the required accelerating voltage. Owing to these features of the sample, further analyses could be performed (material contrast and energy-dispersive X-ray spectroscopy (EDS)), which confirmed the presence of nanoparticles inside the cells. The results showed that FE-SEM can enable detailed characterization of nanoparticles in endosomes without the need for contrast staining or metal coating of the sample. Images showing the intracellular distribution of nanoparticles together with cellular morphology can give important information on the biocompatibility and demonstrate the potential of nanoparticle utilization in medicine. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Visualising impregnated chitosan in Pinus radiata early wood cells using light and scanning electron microscopy.

    Science.gov (United States)

    Singh, Adya P; Singh, Tripti; Rickard, Catherine L

    2010-04-01

    Chitosan, a deacetylated product of an abundant naturally occurring biopolymer chitin, has been used in a range of applications, particularly in food and health areas, as an antimicrobial agent. In the work reported here Pinus radiata wood was impregnated with chitosan as an environmentally compatible organic biocide (Eikenes et al., 2005a,b) to protect wood against wood deteriorating microorganisms and to thus prolong the service life of wooden products. We developed sample preparation techniques targeted to visualise impregnated chitosan within wood tissues using light microscope and field-emission scanning electron microscope (FE-SEM). Sections were viewed with the light microscope without staining with a dye as well as after staining with the dye toluidine blue. Light microscopy was also undertaken on sections that had been stained with 1% aqueous osmium tetroxide (OsO(4)). For SEM observations, the sections were treated with OsO(4) and then examined with the FE-SEM, first in the secondary electron imaging mode (SEI) and then in the backscattered electron imaging (BEI) mode, imaging the same areas of a section in both SEI and BEI modes. The preparation techniques employed and the combined use of light and scanning electron microscopy provided valuable complementary information, revealing that chitosan had penetrated into the cavities (cell lumens, intercellular spaces) of all sizes present within wood tissues and had also impregnated early wood cell walls. The information obtained is discussed in relation to its importance in further development of chitosan formulations and refinement of impregnation technologies to optimise chitosan impregnation into and distribution within wood tissues as well as in assessing chitosan efficacy. Copyright 2009 Elsevier Ltd. All rights reserved.

  11. Investigating the use of in situ liquid cell scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nguy, Amanda [Iowa State Univ., Ames, IA (United States)

    2016-02-19

    Engineering nanoparticles with desired shape-dependent properties is the key to many applications in nanotechnology. Although many synthetic procedures exist to produce anisotropic gold nanoparticles, the dynamics of growth are typically unknown or hypothetical. In the case of seed-mediated growth in the presence of DNA into anisotropic nanoparticles, it is not known exactly how DNA directs growth into specific morphologies. A series of preliminary experiments were carried out to contribute to the investigation of the possible mechanism of DNA-mediated growth of gold nanoprisms into gold nanostars using liquid cell scanning transmission electron microscopy (STEM). Imaging in the liquid phase was achieved through the use of a liquid cell platform and liquid cell holder that allow the sample to be contained within a “chip sandwich” between two electron transparent windows. Ex situ growth experiments were performed using Au-T30 NPrisms (30-base thymine oligonucleotide-coated gold nanoprisms) that are expected to grow into gold nanostars. Growth to form these nanostars were imaged using TEM (transmission electron microscopy) and liquid cell STEM (scanning transmission electron microscopy). An attempt to perform in situ growth experiments with the same Au-T30 nanoprisms revealed challenges in obtaining desired morphology results due to the environmental differences within the liquid cell compared to the ex situ environment. Different parameters in the experimental method were explored including fluid line set up, simultaneous and alternating reagent addition, and the effect of different liquid cell volumes to ensure adequate flow of reagents into the liquid cell. Lastly, the binding affinities were compared for T30 and A30 DNA incubated with gold nanoparticles using zeta potential measurements, absorption spectroscopy, and isothermal titration calorimetry (ITC). It was previously reported thymine bases have a lower binding affinity to gold surfaces than adenine

  12. Evaluation of gas chromatography – electron ionization – full scan high resolution Orbitrap mass spectrometry for pesticide residue analysis

    NARCIS (Netherlands)

    Mol, Hans G.J.; Tienstra, Marc; Zomer, Paul

    2016-01-01

    Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application. The relevant aspects for GC-MS

  13. Axisymmetric charge-conservative electromagnetic particle simulation algorithm on unstructured grids: Application to microwave vacuum electronic devices

    Science.gov (United States)

    Na, Dong-Yeop; Omelchenko, Yuri A.; Moon, Haksu; Borges, Ben-Hur V.; Teixeira, Fernando L.

    2017-10-01

    We present a charge-conservative electromagnetic particle-in-cell (EM-PIC) algorithm optimized for the analysis of vacuum electronic devices (VEDs) with cylindrical symmetry (axisymmetry). We exploit the axisymmetry present in the device geometry, fields, and sources to reduce the dimensionality of the problem from 3D to 2D. Further, we employ 'transformation optics' principles to map the original problem in polar coordinates with metric tensor diag (1 ,ρ2 , 1) to an equivalent problem on a Cartesian metric tensor diag (1 , 1 , 1) with an effective (artificial) inhomogeneous medium introduced. The resulting problem in the meridian (ρz) plane is discretized using an unstructured 2D mesh considering TEϕ-polarized fields. Electromagnetic field and source (node-based charges and edge-based currents) variables are expressed as differential forms of various degrees, and discretized using Whitney forms. Using leapfrog time integration, we obtain a mixed E - B finite-element time-domain scheme for the full-discrete Maxwell's equations. We achieve a local and explicit time update for the field equations by employing the sparse approximate inverse (SPAI) algorithm. Interpolating field values to particles' positions for solving Newton-Lorentz equations of motion is also done via Whitney forms. Particles are advanced using the Boris algorithm with relativistic correction. A recently introduced charge-conserving scatter scheme tailored for 2D unstructured grids is used in the scatter step. The algorithm is validated considering cylindrical cavity and space-charge-limited cylindrical diode problems. We use the algorithm to investigate the physical performance of VEDs designed to harness particle bunching effects arising from the coherent (resonance) Cerenkov electron beam interactions within micro-machined slow wave structures.

  14. Critical-point drying and gold sputtering as applied to scanning electron microscopy of human reproductive tissues.

    Science.gov (United States)

    Ludwig, H; Metzger, H; Hafez, E S

    1976-01-01

    Improved techniques have been developed for washing, pinning, fixation, dehydration and critical-point drying of tissues of female and male reproductive tracts, gametes, for viewing by scanning electron microscopy. The sputtering method, performed by an ion gun, is applied to shadow and produce a thin film of gold. Technical details and metal coating are noted which are suitable to improve images of surface ultrastructure of cilia and microvilli. Studies using scanning electron microscopy, histological and histochemical techniques, and cinematography are described.

  15. Next generation non-vacuum, maskless, low temperature nanoparticle ink laser digital direct metal patterning for a large area flexible electronics.

    Directory of Open Access Journals (Sweden)

    Junyeob Yeo

    Full Text Available Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition- and photolithography-based conventional metal patterning processes. The "digital" nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm and high-performance flexible organic field effect transistor arrays.

  16. Next generation non-vacuum, maskless, low temperature nanoparticle ink laser digital direct metal patterning for a large area flexible electronics.

    Science.gov (United States)

    Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P; Ko, Seung Hwan

    2012-01-01

    Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition- and photolithography-based conventional metal patterning processes. The "digital" nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays.

  17. Next Generation Non-Vacuum, Maskless, Low Temperature Nanoparticle Ink Laser Digital Direct Metal Patterning for a Large Area Flexible Electronics

    Science.gov (United States)

    Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P.; Ko, Seung Hwan

    2012-01-01

    Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition– and photolithography-based conventional metal patterning processes. The “digital” nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays. PMID:22900011

  18. Polarized light and scanning electron microscopic investigation of enamel hypoplasia in primary teeth.

    Science.gov (United States)

    Sabel, Nina; Klingberg, Gunilla; Dietz, Wolfram; Nietzsche, Sandor; Norén, Jörgen G

    2010-01-01

    Enamel hypoplasia is a developmental disturbance during enamel formation, defined as a macroscopic defect in the enamel, with a reduction of the enamel thickness with rounded, smooth borders. Information on the microstructural level is still limited, therefore further studies are of importance to better understand the mechanisms behind enamel hypoplasia. To study enamel hypoplasia in primary teeth by means of polarized light microscopy and scanning electron microscopy. Nineteen primary teeth with enamel hypoplasia were examined in a polarized light microscope and in a scanning electron microscope. The cervical and incisal borders of the enamel hypoplasia had a rounded appearance, as the prisms in the rounded cervical area of the hypoplasia were bent. The rounded borders had a normal surface structure whereas the base of the defects appeared rough and porous. Morphological findings in this study indicate that the aetiological factor has a short duration and affects only certain ameloblasts. The bottom of the enamel hypoplasia is porous and constitutes possible pathways for bacteria into the dentin.

  19. Analysis of acute impact of oleoresin capsicum on rat nasal mucosa using scanning electron microscopy.

    Science.gov (United States)

    Catli, Tolgahan; Acar, Mustafa; Olgun, Yüksel; Dağ, İlknur; Cengiz, Betül Peker; Cingi, Cemal

    2015-01-01

    Analysis of acute cellular changes seen in nasal mucosa of Wistar-Albino rats exposed to different doses of oleoresin capsicum for various time periods by means of scanning electron microscopy. Thirty-five Wistar-Albino rats were divided into five groups of seven rats each. 6-gram oleoresin capsicum per second was sprayed into cages of the groups except group 1. Spray times and duration of exposure to pepper gasses were different for each group. Thirty minutes after the exposure, the animals were killed and specimens from their nasal mucosas were harvested and examined under scanning electron microscope. Mucosal damage was scored from 0-4 points. Mean values of nasal mucosa damage scores of the groups were calculated and compared statistically. Average damage scores of the groups exposed to identical doses of oleoresin capsicum for various exposure times were compared and a statistically significant difference was seen between Groups 2 and 3 (p 0.05). Average damage scores of the groups exposed to various doses for identical exposure times were compared, and statistically significant differences were observed between Groups 2 and 4 and also Groups 3 and 5 (p < 0.05). Outcomes of our study have demonstrated that pepper gas exerts destructive changes on rat nasal mucosa. The extent of these destructive changes increases with the prolonged exposure to higher doses. Besides, exposure time also stands out as an influential factor on the extent of the destructive changes.

  20. Fast Orthogonal Row-Column Electronic Scanning With Top-Orthogonal-to-Bottom Electrode Arrays.

    Science.gov (United States)

    Ceroici, Chris; Harrison, Tyler; Zemp, Roger J

    2017-06-01

    Recently, top-orthogonal-to-bottom electrode 2-D arrays were introduced as a practical design for 3-D ultrasound imaging without requiring the wiring of a 2-D grid of elements. However, previously proposed imaging schemes suffered from speed or image-quality limitations. Here, we propose a new imaging scheme which we call Fast Orthogonal Row-Column Electronic Scanning (FORCES). This new approach takes advantage of bias sensitivity to enable high-quality and fast B-scan imaging. We compare this imaging scheme with an equivalent linear array, a previously proposed row-column imaging scheme, as well as with the Explososcan imaging scheme for 2-D arrays through simulations. In a point phantom simulation, the lateral (azimuthal) resolution of a 64 ×64 element 6.67-MHz λ /2-pitch array using the FORCES imaging scheme with an f-number of 1.7 was 0.52 mm with similar in-plane image quality to an equivalent linear array but with improved and electronically steerable elevational resolution. When compared with other 3-D imaging schemes in point phantom simulations, the FORCES imaging scheme showed an azimuthal resolution improvement of 54% compared with Explososcan. Compared with a previously introduced row-column method, the FORCES imaging scheme had similar resolution but a 25-dB decrease in sidelobe amplitude, significantly impacting contrast to noise in scattering phantoms.

  1. Ultrastructural analysis of testicular tissue and sperm by transmission and scanning electron microscopy.

    Science.gov (United States)

    Chemes, Hector E

    2013-01-01

    Transmission electron microscopy (TEM) studies have provided the basis for an in-depth understanding of the cell biology and normal functioning of the testis and male gametes and have opened the way to characterize the functional role played by specific organelles in spermatogenesis and sperm function. The development of the scanning electron microscope (SEM) extended these boundaries to the recognition of cell and organ surface features and the architectural array of cells and tissues. The merging of immunocytochemical and histochemical approaches with electron microscopy has completed a series of technical improvements that integrate structural and functional features to provide a broad understanding of cell biology in health and disease. With these advances the detailed study of the intricate structural and molecular organization as well as the chemical composition of cellular organelles is now possible. Immunocytochemistry is used to identify proteins or other components and localize them in specific cells or organelles with high specificity and sensitivity, and histochemistry can be used to understand their function (i.e., enzyme activity). When these techniques are used in conjunction with electron microscopy their resolving power is further increased to subcellular levels. In the present chapter we will describe in detail various ultrastructural techniques that are now available for basic or translational research in reproductive biology and reproductive medicine. These include TEM, ultrastructural immunocytochemistry, ultrastructural histochemistry, and SEM.

  2. New insights into subsurface imaging of carbon nanotubes in polymer composites via scanning electron microscopy.

    Science.gov (United States)

    Zhao, Minhua; Ming, Bin; Kim, Jae-Woo; Gibbons, Luke J; Gu, Xiaohong; Nguyen, Tinh; Park, Cheol; Lillehei, Peter T; Villarrubia, J S; Vladár, András E; Alexander Liddle, J

    2015-02-27

    Despite many studies of subsurface imaging of carbon nanotube (CNT)-polymer composites via scanning electron microscopy (SEM), significant controversy exists concerning the imaging depth and contrast mechanisms. We studied CNT-polyimide composites and, by three-dimensional reconstructions of captured stereo-pair images, determined that the maximum SEM imaging depth was typically hundreds of nanometers. The contrast mechanisms were investigated over a broad range of beam accelerating voltages from 0.3 to 30 kV, and ascribed to modulation by embedded CNTs of the effective secondary electron (SE) emission yield at the polymer surface. This modulation of the SE yield is due to non-uniform surface potential distribution resulting from current flows due to leakage and electron beam induced current. The importance of an external electric field on SEM subsurface imaging was also demonstrated. The insights gained from this study can be generally applied to SEM nondestructive subsurface imaging of conducting nanostructures embedded in dielectric matrices such as graphene-polymer composites, silicon-based single electron transistors, high resolution SEM overlay metrology or e-beam lithography, and have significant implications in nanotechnology.

  3. Quantitative atomic resolution mapping using high-angle annular dark field scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Van Aert, S., E-mail: sandra.vanaert@ua.ac.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Verbeeck, J. [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Erni, R. [National Center for Electron Microscopy, Ernest Orlando Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 72R0150, Berkeley, CA 94720 (United States); Bals, S. [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Luysberg, M. [Institute of Solid State Research and Ernst Ruska Center for Microscopy and Spectroscopy with Electrons, Helmholtz Research Center Juelich, 52425 Juelich (Germany); Dyck, D. Van; Tendeloo, G. Van [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium)

    2009-09-15

    A model-based method is proposed to relatively quantify the chemical composition of atomic columns using high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. The method is based on a quantification of the total intensity of the scattered electrons for the individual atomic columns using statistical parameter estimation theory. In order to apply this theory, a model is required describing the image contrast of the HAADF STEM images. Therefore, a simple, effective incoherent model has been assumed which takes the probe intensity profile into account. The scattered intensities can then be estimated by fitting this model to an experimental HAADF STEM image. These estimates are used as a performance measure to distinguish between different atomic column types and to identify the nature of unknown columns with good accuracy and precision using statistical hypothesis testing. The reliability of the method is supported by means of simulated HAADF STEM images as well as a combination of experimental images and electron energy-loss spectra. It is experimentally shown that statistically meaningful information on the composition of individual columns can be obtained even if the difference in averaged atomic number Z is only 3. Using this method, quantitative mapping at atomic resolution using HAADF STEM images only has become possible without the need of simultaneously recorded electron energy loss spectra.

  4. New Insights on Subsurface Imaging of Carbon Nanotubes in Polymer Composites via Scanning Electron Microscopy

    Science.gov (United States)

    Zhao, Minhua; Ming, Bin; Kim, Jae-Woo; Gibbons, Luke J.; Gu, Xiaohong; Nguyen, Tinh; Park, Cheol; Lillehei, Peter T.; Villarrubia, J. S.; Vladar, Andras E.; hide

    2015-01-01

    Despite many studies of subsurface imaging of carbon nanotube (CNT)-polymer composites via scanning electron microscopy (SEM), significant controversy exists concerning the imaging depth and contrast mechanisms. We studied CNT-polyimide composites and, by threedimensional reconstructions of captured stereo-pair images, determined that the maximum SEM imaging depth was typically hundreds of nanometers. The contrast mechanisms were investigated over a broad range of beam accelerating voltages from 0.3 to 30 kV, and ascribed to modulation by embedded CNTs of the effective secondary electron (SE) emission yield at the polymer surface. This modulation of the SE yield is due to non-uniform surface potential distribution resulting from current flows due to leakage and electron beam induced current. The importance of an external electric field on SEM subsurface imaging was also demonstrated. The insights gained from this study can be generally applied to SEM nondestructive subsurface imaging of conducting nanostructures embedded in dielectric matrices such as graphene-polymer composites, silicon-based single electron transistors, high resolution SEM overlay metrology or e-beam lithography, and have significant implications in nanotechnology.

  5. High resolution surface scanning of Thick-GEM for single photo-electron detection

    Science.gov (United States)

    Hamar, G.; Varga, D.

    2012-12-01

    An optical system for high resolution scanning of TGEM UV photon detection systems is introduced. The structure exploits the combination of a single Au-coated TGEM under study, and an asymmetric MWPC (Close Cathode Chamber) as post-amplification stage. A pulsed UV LED source with emission down to 240 nm has been focused to a spot of 0.07 mm on the TGEM surface, and single photo-electron charge spectra has been recorded over selected two dimensional regions. This way, the TGEM gain (order of 10-100) and TGEM photo-electron detection efficiency is clearly separated, unlike in case of continuous illumination. The surface structure connected to the TGEM photon detection is well observable, including inefficiencies in the holes and at the symmetry points between holes. The detection efficiency as well as the gas gain are fluctuating from hole to hole. The gain is constant in the hexagon around any hole, pointing to the fact that the gain depends on hole geometry, and less on the position where the electron enters. The detection probability map strongly changes with the field strength above the TGEM surface, in relation to the change of the actual surface field configuration. The results can be confronted with position-dependent simulations of TGEM electron transfer and gas multiplication.

  6. Weak-beam scanning transmission electron microscopy for quantitative dislocation density measurement in steels.

    Science.gov (United States)

    Yoshida, Kenta; Shimodaira, Masaki; Toyama, Takeshi; Shimizu, Yasuo; Inoue, Koji; Yoshiie, Toshimasa; Milan, Konstantinovic J; Gerard, Robert; Nagai, Yasuyoshi

    2017-04-01

    To evaluate dislocations induced by neutron irradiation, we developed a weak-beam scanning transmission electron microscopy (WB-STEM) system by installing a novel beam selector, an annular detector, a high-speed CCD camera and an imaging filter in the camera chamber of a spherical aberration-corrected transmission electron microscope. The capabilities of the WB-STEM with respect to wide-view imaging, real-time diffraction monitoring and multi-contrast imaging are demonstrated using typical reactor pressure vessel steel that had been used in an European nuclear reactor for 30 years as a surveillance test piece with a fluence of 1.09 × 1020 neutrons cm-2. The quantitatively measured size distribution (average loop size = 3.6 ± 2.1 nm), number density of the dislocation loops (3.6 × 1022 m-3) and dislocation density (7.8 × 1013 m m-3) were carefully compared with the values obtained via conventional weak-beam transmission electron microscopy studies. In addition, cluster analysis using atom probe tomography (APT) further demonstrated the potential of the WB-STEM for correlative electron tomography/APT experiments. © The Author 2017. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Study of fossil bones by synchrotron radiation micro-spectroscopic techniques and scanning electron microscopy.

    Science.gov (United States)

    Zougrou, I M; Katsikini, M; Pinakidou, F; Paloura, E C; Papadopoulou, L; Tsoukala, E

    2014-01-01

    Earlymost Villafranchian fossil bones of an artiodactyl and a perissodactyl from the Milia excavation site in Grevena, Greece, were studied in order to evaluate diagenetic effects. Optical microscopy revealed the different bone types (fibro-lamellar and Haversian, respectively) of the two fragments and their good preservation state. The spatial distribution of bone apatite and soil-originating elements was studied using micro-X-ray fluorescence (µ-XRF) mapping and scanning electron microscopy. The approximate value of the Ca/P ratio was 2.2, as determined from scanning electron microscopy measurements. Bacterial boring was detected close to the periosteal region and Fe bearing oxides were found to fill bone cavities, e.g. Haversian canals and osteocyte lacunae. In the perissodactyl bone considerable amounts of Mn were detected close to cracks (the Mn/Fe weight ratio takes values up to 3.5). Goethite and pyrite were detected in both samples by means of metallographic microscopy. The local Ca/P ratio determined with µ-XRF varied significantly in metal-poor spots indicating spatial inhomogeneities in the ionic substitutions. XRF line scans that span the bone cross sections revealed that Fe and Mn contaminate the bones from both the periosteum and medullar cavity and aggregate around local maxima. The formation of goethite, irrespective of the local Fe concentration, was verified by the Fe K-edge X-ray absorption fine structure (XAFS) spectra. Finally, Sr K-edge extended XAFS (EXAFS) revealed that Sr substitutes for Ca in bone apatite without obvious preference to the Ca1 or Ca2 unit-cell site occupation.

  8. Vacuum extraction

    DEFF Research Database (Denmark)

    Maagaard, Mathilde; Oestergaard, Jeanett; Johansen, Marianne

    2012-01-01

    Objectives. To develop and validate an Objective Structured Assessment of Technical Skills (OSATS) scale for vacuum extraction. Design. Two part study design: Primarily, development of a procedure-specific checklist for vacuum extraction. Hereafter, validationof the developed OSATS scale for vacuum...

  9. Vacuum Referred Binding Energy of the Single 3d, 4d, or 5d Electron in Transition Metal and Lanthanide Impurities in Compounds

    NARCIS (Netherlands)

    Rogers, E.G.; Dorenbos, P.

    2014-01-01

    The vacuum referred binding energy (VRBE) of the single electron in the lowest energy 3d level of Sc2 +, V4 +, Cr5 +, the lowest 4d level of Y2 +, Zr3 +, Nb4 +, Mo5 + and the lowest 5d level of Ta4 +, and W5 + in various compounds are determined by means of the chemical shift model. They will be

  10. Skeletal growth phases of the cold-water coral Lophelia pertusa shown by scanning electron microscope and electron backscatter diffraction

    Science.gov (United States)

    Mouchi, Vincent; Vonlanthen, Pierre; Verrecchia, Eric P.; Crowley, Quentin G.

    2016-04-01

    Lophelia pertusa is a cold-water coral, which may form reefs by the association of multiple coralites within which a polyp lives. Each individual polyp builds an aragonite skeleton by an initial phase of early mineralization (traditionally referred to as centres of calcification) from which aragonite fibres grow in thickening deposits. The skeleton wall features successive optically opaque and translucent bands previously attributed to different regimes of growth as either uniform in crystal orientation (translucent bands) or with a chaotic organization (opaque bands). The processes involved in any organizational changes are still unknown. Microlayers in the coral wall, which represent separate periods of skeletal growth, have been recently identified and described. These growth patterns are readily visible under scanning electron microscope (SEM) after etching in dilute formic acid, but they do not necessarily form continuously visible structures. Here we present high quality SEM images and electron backscatter diffraction (EBSD) maps to study aragonite fibre orientation across the wall of L. pertusa. Both microlayers and opaque and translucent bands are compared to the crystallographic orientation of the aragonite fibres. EBSD maps and SEM images indicate that aragonite fibres do not exhibit a chaotic orientation, even in opaque bands. The absence of continuity of microlayers is partially explained by an association of multiple crystallographic preferred orientations of aragonite fibres. In the case of L. pertusa, careful textural characterisation is necessary prior to elemental or isotope analysis in order to select a skeletal transect representing a linear and continuous time period.

  11. Nanoscale Imaging of Whole Cells Using a Liquid Enclosure and a Scanning Transmission Electron Microscope

    Science.gov (United States)

    Peckys, Diana B.; Veith, Gabriel M.; Joy, David C.; de Jonge, Niels

    2009-01-01

    Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM) using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7) were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wet-STEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM) laboratory. PMID:20020038

  12. Nanoscale imaging of whole cells using a liquid enclosure and a scanning transmission electron microscope.

    Directory of Open Access Journals (Sweden)

    Diana B Peckys

    2009-12-01

    Full Text Available Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7 were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wet-STEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM laboratory.

  13. Direct imaging of defect formation in strained organic flexible electronics by Scanning Kelvin Probe Microscopy.

    Science.gov (United States)

    Cramer, Tobias; Travaglini, Lorenzo; Lai, Stefano; Patruno, Luca; de Miranda, Stefano; Bonfiglio, Annalisa; Cosseddu, Piero; Fraboni, Beatrice

    2016-12-02

    The development of new materials and devices for flexible electronics depends crucially on the understanding of how strain affects electronic material properties at the nano-scale. Scanning Kelvin-Probe Microscopy (SKPM) is a unique technique for nanoelectronic investigations as it combines non-invasive measurement of surface topography and surface electrical potential. Here we show that SKPM in non-contact mode is feasible on deformed flexible samples and allows to identify strain induced electronic defects. As an example we apply the technique to investigate the strain response of organic thin film transistors containing TIPS-pentacene patterned on polymer foils. Controlled surface strain is induced in the semiconducting layer by bending the transistor substrate. The amount of local strain is quantified by a mathematical model describing the bending mechanics. We find that the step-wise reduction of device performance at critical bending radii is caused by the formation of nano-cracks in the microcrystal morphology of the TIPS-pentacene film. The cracks are easily identified due to the abrupt variation in SKPM surface potential caused by a local increase in resistance. Importantly, the strong surface adhesion of microcrystals to the elastic dielectric allows to maintain a conductive path also after fracture thus providing the opportunity to attenuate strain effects.

  14. Simultaneous measurement of lateral and vertical size of nanoparticles using transmission scanning electron microscopy (TSEM)

    Science.gov (United States)

    Buhr, E.; Bug, M. U.; Bergmann, D.; Cizmar, P.; Frase, C. G.

    2017-03-01

    A scanning electron microscope operated in transmission mode (TSEM) enables both the measurement of the lateral and vertical size (thickness) of nanoparticles. The lateral size is measured with a previously described technique where the particle boundary is determined in the TSEM image. Particle thickness is deduced from the TSEM signal level measured at the centre of the particle, which requires prior knowledge of the expected TSEM signal level. We applied different and well-known Monte-Carlo based simulation tools (Geant4 and MCSEM) to describe the electron diffusion in solid states and to calculate the expected TSEM signals taking into account particle and instrument properties. The simulation results of the different simulation models differ slightly revealing current limits of small-angle and low-energy electron scattering modelling in solid states. Nonetheless, the method allows one to correlate lateral and vertical particle thickness and thus to obtain additional information about the 3D morphology of nanoparticles. We demonstrate the method for silica particles with sizes in the range of about 10 nm-100 nm.

  15. Scanning electron microscopy of individual nanoparticle bio-markers in liquid

    Energy Technology Data Exchange (ETDEWEB)

    Liv, Nalan, E-mail: n.liv@tudelft.nl; Lazić, Ivan; Kruit, Pieter; Hoogenboom, Jacob P.

    2014-08-01

    We investigated SEM imaging of nanoparticle biomarkers suspended below a thin membrane, with the ultimate goal of integrating functional fluorescence and structural SEM measurements of samples kept at ambient or hydrated conditions. In particular, we investigated how resolving power in liquid SEM is affected by the interaction of the electron beam with the membrane. Simulations with the Geant4-based Monte Carlo scheme developed by Kieft and Bosch (2008) [1] are compared to experimental results with suspended nanoparticles. For 20 nm and 50 nm thin membranes, we found a beam broadening of 1.5 nm and 3 nm, respectively, with an excellent agreement between simulations and experiments. 15 nm Au nanoparticles and bio-functionalized core-shell quantum dots can be individually resolved in denser clusters. We demonstrated the imaging of single EGF-conjugated quantum dots docked at filopodia during cellular uptake with both fluorescence microscopy and SEM simultaneously. These results open novel opportunities for correlating live fluorescence microscopy with structural electron microscopy. - Highlights: • We investigate the achievable resolution in liquid scanning electron microscopy (SEM). • We demonstrate liquid SEM imaging of individual fluorescent nanoparticle bio-markers • We show imaging of cellular QDot uptake with simultaneous fluorescence microscopy and SEM. • The positions of individual QDots can be resolved with details on cellular structure.

  16. Bottlenecks in bog pine multiplication by somatic embryogenesis and their visualization with the environmental scanning electron microscope

    Czech Academy of Sciences Publication Activity Database

    Vlašínová, H.; Neděla, Vilém; Dordevic, B.; Havel, J.

    2017-01-01

    Roč. 254, č. 4 (2017), s. 1487-1497 ISSN 0033-183X R&D Projects: GA ČR(CZ) GA14-22777S Institutional support: RVO:68081731 Keywords : somatic embryogenesis * pinus uncinata subsp uliginosa * abnormalities * environmental scanning electron microscope Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 2.870, year: 2016

  17. Scanning electron microscopy of Leucochloridiomorpha constantiae during development from metacercaria to adult.

    Science.gov (United States)

    Font, W F; Wittrock, D D

    1980-12-01

    Scanning electron microscopy revealed that the tegument of Leucochloridiomorpha constantiae metacercariae was marked with interconnected longitudinal and transverse ridges. Alteration of the ridges began within 1 hr after implantation into the chick coelom. Ridges were completely lost by the 4th hr, leaving a smooth tegument. Body shape altered from that of a tapered metacercaria to a plump, rounded adult within 3 days, and was accompanied by doubling of the acetabular diameter. Papillae, present in both the metacercaria and adult, were located on the suckers, genital orifice, and body surface. The microtopography of the tegument consisted of knoblike protuberances that gave the surface a cobblestonelike appearance. Tegumental knobs in te vicinity of the genital pore contained minute, rounded inclusions.

  18. Improved visualization of vertebrate nuclear pore complexes by field emission scanning electron microscopy.

    Science.gov (United States)

    Shaulov, Lihi; Harel, Amnon

    2012-03-07

    Field emission scanning electron microscopy (FESEM) can provide high-resolution three-dimensional surface imaging of many biological structures, including nuclear envelopes and nuclear pore complexes (NPCs). For this purpose, it is important to preserve NPCs as close as possible to their native morphology, embedded in undamaged nuclear membranes. We present optimized methodologies for FESEM imaging in a cell-free reconstitution system and for the direct visualization of mammalian cell nuclei. The use of anchored chromatin templates in the cell-free system is particularly advantageous for imaging fragile intermediates inhibited at early stages of assembly. Our new method for exposing the surface of mammalian nuclei results in an unprecedented quality of NPC images, avoiding detergent-induced and physical damage. These new methodologies pave the way for the combined use of FESEM imaging with biochemical and genetic manipulation, in cell-free systems and in mammalian cells. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. The low-temperature method for study of coniferous tissues in the environmental scanning electron microscope.

    Science.gov (United States)

    Neděla, Vilém; Tihlaříková, Eva; Hřib, Jiří

    2015-01-01

    The use of non-standard low-temperature conditions in environmental scanning electron microscopy might be promising for the observation of coniferous tissues in their native state. This study is aimed to analyse and evaluate the method based on the principle of low-temperature sample stabilization. We demonstrate that the upper mucous layer is sublimed and a microstructure of the sample surface can be observed with higher resolution at lower gas pressure conditions, thanks to a low-temperature method. An influence of the low-temperature method on sample stability was also studied. The results indicate that high-moisture conditions are not suitable for this method and often cause the collapse of samples. The potential improvement of stability to beam damage has been demonstrated by long-time observation at different operation parameters. We finally show high applicability of the low-temperature method on different types of conifers and Oxalis acetosella. © 2014 Wiley Periodicals, Inc.

  20. Scanning Electron Microscopic Studies of the Pecten Oculi in the Quail (Coturnix coturnix japonica

    Directory of Open Access Journals (Sweden)

    Aris F. Pourlis

    2013-01-01

    Full Text Available The main purpose of this study is to extend the microscopic investigations of the pecten oculi in the quail in order to add some information on the unresolved functional anatomy of this unique avian organ. The pecten oculi of the quail was studied by scanning electron microscopy. Eighteen- to-twenty two highly vascularised accordion-like folds were joined apically by a heavily pigmented bridge of tissue, which holds the pecten in a fanlike shape, widest at the base. The structure of the double layered limiting membrane was recorded. The presence of hyalocytes with macrophage-like appearance was illustrated. It is assumed that the pecten oculi of the quail resembles that of the chicken. Illustrated morphological features of this species may add information on the active physiological role of the pecten. But still, the functional significance of this organ is a matter of controversies.

  1. Scanning electron microscopy of the tegumental surface of adult Schistosoma spindale.

    Science.gov (United States)

    Kruatrachue, M; Riengrojpitak, S; Upatham, E S; Sahaphong, S

    1983-09-01

    The tegumental surfaces of adult male and female of Schistosoma spindale were studied by scanning electron microscopy. In general, the body surface of the male appears to be fairly uniform from anterior end to posterior end. It is characterized by the presence of transverse ridges and papillae of various types. These papillae are distributed fairly regularly over the whole body surface of the worm. The tegument lining the gynecophoral canal of the male worm is covered with numerous spines interspersed with papillae, some without cilia and some with crater-like holes in the centres and apical cilia. The tegument of the female worm is covered with smooth and perforated ridges and sensory bulbs with apical nodules.

  2. Standard practice for calibrating the magnification of a scanning electron microscope

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers general procedures necessary for the calibration of magnification of scanning electron microscopes. The relationship between true magnification and indicated magnification is a complicated function of operating conditions. Therefore, this practice must be applied to each set of standard operating conditions to be used. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Frequency-doubled Alexandrite laser for use in periodontology: a scanning electron microscopic investigation

    Science.gov (United States)

    Rechmann, Peter; Hennig, Thomas

    1996-12-01

    During prior studies it could be demonstrated that engaging a frequency double Alexandrite-laser allows a fast and strictly selective ablation of supra- and subgingival calculus. Furthermore, the removal of unstained microbial plaque was observed. First conclusions were drawn following light microscopic investigations on undecalcified sections of irradiated teeth. In the present study the cementum surface after irradiation with a frequency doubled Alexandrite-laser was observed by means of a scanning electron microscope. After irradiation sections of teeth were dried in alcohol and sputtered with gold. In comparison irradiated cementum surfaces of unerupted operatively removed wisdom teeth and tooth surfaces after the selective removal of calculus were investigated. A complete removal of calculus was observed as well as a remaining smooth surface of irradiated cementum.

  4. Morphology of the dentin structure of sloths Bradypus tridactylus: a light and scanning electron microscopy investigation.

    Science.gov (United States)

    Santana, L N S; Barbosa, L V M; Teixeira, F B; Costa, A M P; Fernandes, L M P; Lima, R R

    2013-12-01

    The aim of this study was to describe the dentine morphology of sloths (Bradypus tridactylus). The sloth teeth were removed and prepared for light microscopy (LM) and scanning electron microscopy analyses (SEM). LM revealed two patterns of tubular dentins: an outer with dentinary tubules over the all tooth length and one in the inner part with larger diameter and more spaced tubules, when compared to those present in the outer dentine. These findings were confirmed by SEM, which revealed a tubular pattern in the outer dentine like in humans. The inner dentine displayed pared grouped tubules that were characterized as vascular channels. It can be concluded that this sloth species present two types of dentins: an inner dentin (ortodentin) and an outer dentin characterized as a vascular dentin. This suggests a partial evolutive/adaptive process of this dental tissue, as compared to other mammalian species. © 2013 Blackwell Verlag GmbH.

  5. Anterior lens epithelium in cataract patients with retinitis pigmentosa - scanning and transmission electron microscopy study.

    Science.gov (United States)

    Andjelic, Sofija; Drašlar, Kazimir; Hvala, Anastazija; Hawlina, Marko

    2017-05-01

    In retinitis pigmentosa (RP) patients, relatively minor lens opacity in central part of posterior pole of the lens may cause disproportionate functional symptoms requiring cataract operation. To investigate the possible structural reasons for this opacity development, we studied the structure of the lens epithelium of patients with RP. The anterior lens capsule (aLC: basement membrane and associated lens epithelial cells, LECs) was obtained from cataract surgery and prepared for scanning and transmission electron microscopy (SEM and TEM). Both SEM and TEM show a number of abnormal features in the anterior lens epithelium of cataract patients with RP. The abnormalities appear mainly as holes, thinning and degradation of the epithelium, with the dimensions from cataractous lens. We suggest that the lens epithelium has a role in the development of the cataract in patients with RP. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Scanning electron microscopic observations of fibrous structure of cemento-dentinal junction in healthy teeth.

    Science.gov (United States)

    Pratebha, B; Jaikumar, N D; Sudhakar, R

    2014-01-01

    The cemento-dentinal junction (CDJ) is a structural and biologic link between cementum and dentin present in the roots of teeth. Conflicting reports about the origin, structure and composition of this layer are present in literature. The width of this junctional tissue is reported to be about 2-4 μm with adhesion of cementum and dentin by proteoglycans and by collagen fiber intermingling. The objective of this study is to observe and report the fibrous architecture of the CDJ of healthy tooth roots. A total of 15 healthy teeth samples were collected, sectioned into halves, demineralized in 5% ethylenediaminetetraacetic acid, processed using NaOH maceration technique and observed under a scanning electron microscope. The CDJ appeared to be a fibril poor groove with a width of 2-4 µm. Few areas of collagen fiber intermingling could be appreciated. A detailed observation of these tissues has been presented.

  7. Large area strain analysis using scanning transmission electron microscopy across multiple images

    Energy Technology Data Exchange (ETDEWEB)

    Oni, A. A.; Sang, X.; LeBeau, J. M., E-mail: jmlebeau@ncsu.edu [Department of Materials Science and Engineering, North Carolina State University, Raleigh, North Carolina 27695-7907 (United States); Raju, S. V.; Saxena, S. [Center for the Study of Matter under Extreme Conditions, Florida International University, Miami, Florida 33199 (United States); Dumpala, S.; Broderick, S.; Rajan, K. [Department of Materials Science and Engineering, Iowa State University, Ames, Iowa 50011 (United States); Kumar, A.; Sinnott, S. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611 (United States)

    2015-01-05

    Here, we apply revolving scanning transmission electron microscopy to measure lattice strain across a sample using a single reference area. To do so, we remove image distortion introduced by sample drift, which usually restricts strain analysis to a single image. Overcoming this challenge, we show that it is possible to use strain reference areas elsewhere in the sample, thereby enabling reliable strain mapping across large areas. As a prototypical example, we determine the strain present within the microstructure of a Ni-based superalloy directly from atom column positions as well as geometric phase analysis. While maintaining atomic resolution, we quantify strain within nanoscale regions and demonstrate that large, unit-cell level strain fluctuations are present within the intermetallic phase.

  8. The migration of lymphocytes across the vascular endothelium in lymph nodes: a scanning electron microscopic study.

    Science.gov (United States)

    Nishi, M; Hamada, N; Nomura, H; Mastueda, M; Aiko, T

    1979-03-01

    Endothelial cells of Postcapillary Venules (PCV) and the passage of lymphocytes through the wall of PCV were investigated with Scanning Electron Microscope (SEM) in mesenteric lymph nodes of rats. Individual endothelial cells of PCV in the lymph node did not have flat surface or were not typically cubic, but swelled at the central part assuming a foot ball-like shape. Circulating lymphocytes are considered to migrate into lymphatic tissues through the wall of PCV from the blood stream. Two hypotheses, inter-endothelial cell passage and intra-endothelial cell passage, have been proposed. The three-dimensional studies on lymphocytes passing the wall with SEM confirmed that migrating lymphocytes pushes their way through the intercellular space with pressing the adjoining endothelial cells from beginning to end, supporting the former hypothesis. Invasion of lymphocytes into endothelial cells were not observed.

  9. Determination of the sequence of intersecting lines using Focused Ion Beam/Scanning Electron Microscope.

    Science.gov (United States)

    Kim, Jiye; Kim, MinJung; An, JinWook; Kim, Yunje

    2016-05-01

    The aim of this study was to verify that the combination of focused ion beam (FIB) and scanning electron microscope/energy-dispersive X-ray (SEM/EDX) could be applied to determine the sequence of line crossings. The samples were transferred into FIB/SEM for FIB milling and an imaging operation. EDX was able to explore the chemical components and the corresponding elemental distribution in the intersection. The technique was successful in determining the sequence of heterogeneous line intersections produced using gel pens and red sealing ink with highest success rate (100% correctness). These observations show that the FIB/SEM was the appropriate instrument for an overall examination of document. © 2016 American Academy of Forensic Sciences.

  10. Investigation of Nematode Diversity using Scanning Electron Microscopy and Fluorescent Microscopy

    Science.gov (United States)

    Seacor, Taylor; Howell, Carina

    2013-03-01

    Nematode worms account for the vast majority of the animals in the biosphere. They are colossally important to global public health as parasites, and to agriculture both as pests and as beneficial inhabitants of healthy soil. Amphid neurons are the anterior chemosensory neurons in nematodes, mediating critical behaviors including chemotaxis and mating. We are examining the cellular morphology and external anatomy of amphid neurons, using fluorescence microscopy and scanning electron microscopy, respectively, of a wide range of soil nematodes isolated in the wild. We use both classical systematics (e.g. diagnostic keys) and molecular markers (e.g. ribosomal RNA) to classify these wild isolates. Our ultimate aim is to build a detailed anatomical database in order to dissect genetic pathways of neuronal development and function across phylogeny and ecology. Research supported by NSF grants 092304, 0806660, 1058829 and Lock Haven University FPDC grants

  11. Evaluation of vermicompost maturity using scanning electron microscopy and paper chromatography analysis.

    Science.gov (United States)

    Senthil Kumar, D; Satheesh Kumar, P; Rajendran, N M; Uthaya Kumar, V; Anbuganapathi, G

    2014-04-02

    Vermicompost was produced from flower waste inoculated with biofertilizers using the earthworm Eisenia fetida. Principal component analysis (PCA) and cluster analysis (CA) were carried out on the basis of physicochemical parameters of vermicomposted samples. From the results of the PCA and CA, it was possible to classify two different groups of vermicompost samples in the following categories: E2 and E5; and E1, E3, E4, and control. Scanning electron microscopy and biodynamic circular paper chromatography analysis were used to investigate the changes in surface morphology and functional groups in the control and vermicompost products. SEM analysis of E1-E5 shows more fragment and pores than the control. Chromatographic analysis of vermicompost indicated the mature condition of the compost materials.

  12. Imaging thiol redox status in murine tumors in vivo with rapid-scan electron paramagnetic resonance

    Science.gov (United States)

    Epel, Boris; Sundramoorthy, Subramanian V.; Krzykawska-Serda, Martyna; Maggio, Matthew C.; Tseytlin, Mark; Eaton, Gareth R.; Eaton, Sandra S.; Rosen, Gerald M.; Kao, Joseph P. Y.; Halpern, Howard J.

    2017-03-01

    Thiol redox status is an important physiologic parameter that affects the success or failure of cancer treatment. Rapid scan electron paramagnetic resonance (RS EPR) is a novel technique that has shown higher signal-to-noise ratio than conventional continuous-wave EPR in in vitro studies. Here we used RS EPR to acquire rapid three-dimensional images of the thiol redox status of tumors in living mice. This work presents, for the first time, in vivo RS EPR images of the kinetics of the reaction of 2H,15N-substituted disulfide-linked dinitroxide (PxSSPx) spin probe with intracellular glutathione. The cleavage rate is proportional to the intracellular glutathione concentration. Feasibility was demonstrated in a FSa fibrosarcoma tumor model in C3H mice. Similar to other in vivo and cell model studies, decreasing intracellular glutathione concentration by treating mice with L-buthionine sulfoximine (BSO) markedly altered the kinetic images.

  13. A morphological study of molecularly imprinted polymers using the scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Paniagua Gonzalez, Gema [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain)]. E-mail: gpaniagua@pas.uned.es; Fernandez Hernando, Pilar [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain); Durand Alegria, J.S. [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain)

    2006-01-31

    Molecular imprinting is an emerging technique for producing polymers with applications in affinity-based separation, in biomimetic sensors, in catalysis, etc. This variety of uses relies upon the production of polymers with different affinities, specificities, sensitivities and loading capacities. Research into the development of molecular imprinted polymers (MIPs) with new or improved morphologies - which involves modification of the polymerisation process - is therefore underway. This paper reports a comparative study of non-covalent MIPs synthesised by 'bulk' polymerisation using digoxin as template. These were synthesised under different conditions, i.e., changing the functional monomers employed (methacrylic acid or 2-vinylpyridine), the porogens (acetonitrile or dichloromethane) used, and by altering the volume of the latter. The polymerisation process was allowed to proceed either under UV light or in a thermostat-controlled waterbath. The surface morphology (was determined by scanning electron microscopy) and the ability of the different polymers to selectively rebind the template was then evaluated.

  14. [Scanning electron microscopic study of films of the loose connective tissue of mice exposed to DMBA].

    Science.gov (United States)

    Ol'shevskaia, L V

    1979-01-01

    Under examination by scanning electron microscopy were film samples of the subcutaneous connective tissue. The surface of the films from intact mice was even and smooth, fibroblasts have a spread pattern. Following the saline injection the film was even, collagen fibres, differing in the character of surface and the size of diameter, were readily seen. The collagen fibres formed a multilayer system with a definite orientation inside the layer. After DMBA injection the film surface would get uneven and tuberous, the fibroblast body rising over the film surface, thus the orientation of fibres and all strata was disturbed. There was a spacial rearrangement of all tissue components. It is suggested that carcinogenic agents affecting the relationship between tissue components could interfere the contact inhibition of cell division and result in the development of focal cell proliferates.

  15. Descriptive study of Aeolidia papillosa with scanning electron micrographs of the radula

    Energy Technology Data Exchange (ETDEWEB)

    Bertsch, H.

    1974-01-01

    Aeolidia papillosa (Linnaeus, 1761) is a cosmopolitan nudibranch of the northern hemisphere which feeds on sea anemones. The radula of Aeolidia papillosa, here figured by scanning electron micrographs for the first time, has 18 to 28 rows of teeth. Each row consists of a single large, pectinate, arched tooth, which is curved forward, and bears a series of stout, regular, lanceolate tipped denticles. The denticles vary in number: anywhere from 30 to 58 having been reported; the specimen figured in this paper from the Bodega Bay area, California, has 55 denticles. Some specimens show a distinctly wider space separating the central two denticles. This has also been illustrated by Pruvot-Fol and O'Donoghue. Other specimens show no interruption in the midline of the teeth as figured by MacFarland and Marcus. This variation has no geographical correlation, and is not considered of specific importance.

  16. A novel and compact nanoindentation device for in situ nanoindentation tests inside the scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Hu Huang

    2012-03-01

    Full Text Available In situ nanomechanical tests provide a unique insight into mechanical behaviors of materials, such as fracture onset and crack propagation, shear band formation and so on. This paper presents a novel in situ nanoindentation device with dimensions of 103mm×74mm×60mm. Integrating the stepper motor, the piezoelectric actuator and the flexure hinge, the device can realize coarse adjustment of the specimen and precision loading and unloading of the indenter automatically. A novel indenter holder was designed to guarantee that the indenter penetrates into and withdraws from the specimen surface vertically. Closed-loop control of the indentation process was established to solve the problem of nonlinearity of the piezoelectric actuator and to enrich the loading modes. The in situ indentation test of Indium Phosphide (InP inside the scanning electron microscope (SEM was carried out and the experimental result indicates the feasibility of the developed device.

  17. Regenerated middle ear mucosa after tympanoplasty. Part II. Scanning electron microscopy.

    Science.gov (United States)

    Gamoletti, R; Lanzarini, P; Sanna, M; Zini, C

    1986-04-01

    The ultrastructural appearance of the regenerated middle ear epithelium, found at the second operation of staged ICWT with mastoidectomy, has been investigated herein with the scanning electron microscope. The regenerated epithelium consists of flat nonciliated cells, "elevated" nonciliated cells with microvilli, and ciliated cells. Secretory material is present on the surface of the "elevated" nonciliated cells surrounding the ciliated ones. Regeneration of the mucosa occurs following precise topographic differences that mimic the distribution of epithelial cells in the normal middle ear. It is confirmed that a morphologically normal middle ear epithelium regenerates to cover all denuded bone surfaces within 12 months--after first stage ICWT with mastoidectomy--when silicone rubber sheeting has been used to maintain an aerated middle ear and mastoid space.

  18. Colorimeter and scanning electron microscopy analysis of teeth submitted to internal bleaching.

    Science.gov (United States)

    Martin-Biedma, Benjamin; Gonzalez-Gonzalez, Teresa; Lopes, Manuela; Lopes, Luis; Vilar, Rui; Bahillo, José; Varela-Patiño, Purificación

    2010-02-01

    This in vitro study compared the tooth color and the ultrastructure of internal dental tissues before and after internal bleaching. Sodium perborate was placed in the pulp chamber of endodontically treated molars and sealed with intermediate restorative material. The test samples were stored in a physiologic solution, and the bleaching agent was replaced every 7 days. A control group was used. After 1 month, the colors of the test and control samples were measured with a colorimeter, and the internal surfaces were observed under field emission scanning electron microscopy (FESEM). Statistically significant differences were found between the test and control sample colors. The FESEM ultrastructure analysis of the internal enamel and dentin surfaces did not show any changes after the internal bleaching. The results of the present study show that sodium perborate is effective in bleaching nonvital teeth and does not produce ultrastructural changes in the dental tissues. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Use of scanning electron microscopy to monitor nanofibre/cell interaction in digestive epithelial cells.

    Science.gov (United States)

    Millaku, Agron; Drobne, Damjana; Torkar, Matjaz; Novak, Sara; Remškar, Maja; Pipan-Tkalec, Živa

    2013-09-15

    We provide data obtained by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) on the interaction of ingested tungsten nanofibers with epithelial cells of the digestive tubes of a test organism Porcellio scaber. Conventional toxicity endpoints including feeding behaviour, weight loss and mortality were also measured in each investigated animal. No toxicity was detected in any of exposed animals after 14 days of feeding on tungsten nanofiber dosed food, but when nanofibers enter the digestive system they can react with epithelial cells of the digestive tubes, becoming physically inserted into the cells. In this way, nanofibers can injure the epithelial cells of digestive gland tubes when they are ingested with food. Our SEM data suggest that peristaltic forces may have an important role, not predicted by in vitro experiments, in the interactions of nanomaterials with digestive intestinal cells. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Characterization of Emulsions of Fish Oil and Water by Cryo Scanning Electron Microscopy

    DEFF Research Database (Denmark)

    Jensen, Louise Helene Søgaard; Horn, Anna Frisenfeldt; Jacobsen, Charlotte

    to the many double bonds. Emulsions of fish oil in water are potential candidates for a delivery system of fish oil to food products. It has been suggested that oxidation of oil-in-water emulsions is initiated at the interface between oil and water. It has also been proposed that oxidation is to some extent...... dependent on the ultra structure of the emulsion; including the size of oil droplets, their distribution and the thickness of the interface between oil and water. This interface is stabilized by macromolecules such as proteins, phospholipids and hydrocolloids. The main objective of this study...... is to characterize fish oil in water emulsions with respect to oil droplet size, distribution, and ultimately to view the structure and thickness of the interface layer. A freeze-fractured surface viewed at low temperatures under the scanning electron microscope is a promising strategy to reveal variations...

  1. Marginal Leakage of Class V Composite Restorations Assessed Using Microcomputed Tomography and Scanning Electron Microscope.

    Science.gov (United States)

    Rengo, C; Goracci, C; Ametrano, G; Chieffi, N; Spagnuolo, G; Rengo, S; Ferrari, M

    2015-01-01

    The aim of the study was to compare in Class V composite restorations marginal leakage measurements obtained with microcomputed tomography (micro-CT) and scanning electron microscopy (SEM) observations. Class V cavities were prepared on 10 human molars and restored using Optibond FL (Kerr, Orange, CA, USA) and Premise Flowable (Kerr). Sealing ability was evaluated by assessing silver-nitrate penetration depth along enamel and dentin margins. Leakage was quantified using a scoring system. Micro-CT analysis provided 502 cross-sectional images for each tooth. Microleakage evaluation was performed first on three cross-sections corresponding to the sections examined by SEM, then on all 502 of the obtained micro-CT images. SEM observations were performed first at 20× magnification, then, if showing a zero score, at 80× magnification. Enamel and dentin microleakage scores assigned to corresponding sections through micro-CT and SEM (20×) were compared (Wilcoxon signed-rank test, α=0.05). No statistically significant difference in leakage scores emerged between micro-CT and 20×-magnification SEM. Eight tooth sections that were given a zero score under SEM at 20× magnification showed to be infiltrated at the higher magnification (80×). For five teeth a higher score was assigned following scanning of 502 cross-sections than based on the observation of three sections. Micro-CT presents as a valid, nondestructive in vitro method to quantitatively evaluate marginal leakage of adhesive restorations.

  2. Examination of Scanning Electron Microscope and Computed Tomography Images of PICA

    Science.gov (United States)

    Lawson, John W.; Stackpoole, Margaret M.; Shklover, Valery

    2010-01-01

    Micrographs of PICA (Phenolic Impregnated Carbon Ablator) taken using a Scanning Electron Microscope (SEM) and 3D images taken with a Computed Tomography (CT) system are examined. PICA is a carbon fiber based composite (Fiberform ) with a phenolic polymer matrix. The micrographs are taken at different surface depths and at different magnifications in a sample after arc jet testing and show different levels of oxidative removal of the charred matrix (Figs 1 though 13). CT scans, courtesy of Xradia, Inc. of Concord CA, were captured for samples of virgin PICA, charred PICA and raw Fiberform (Fig. 14). We use these images to calculate the thermal conductivity (TC) of these materials using correlation function (CF) methods. CF methods give a mathematical description of how one material is embedded in another and is thus ideally suited for modeling composites like PICA. We will evaluate how the TC of the materials changes as a function of surface depth. This work is in collaboration with ETH-Zurich, which has expertise in high temperature materials and TC modeling (including CF methods).

  3. Preliminary Study of In Vivo Formed Dental Plaque Using Confocal Microscopy and Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    KA. Al-Salihi

    2009-12-01

    Full Text Available Objective: Confocal laser scanning microscopy (CLSM is relatively a new light microscopical imaging technique with a wide range of applications in biological sciences. The primary value of CLSM for the biologist is its ability to provide optical sections from athree-dimensional specimen. The present study was designed to assess the thickness and content of in vivo accumulated dental plaque using CLSM and scanning electron microscopy (SEM.Materials and Methods: Acroflat lower arch splints (acrylic appliance were worn by five participants for three days without any disturbance. The formed plaques were assessed using CLSM combined with vital fluorescence technique and SEM.Results: In this study accumulated dental plaque revealed varied plaque microflora vitality and thickness according to participant’s oral hygiene. The thickness of plaque smears ranged from 40.32 to 140.72 μm and 65.00 to 128.88 μm for live (vital and dead accumulated microorganisms, respectively. Meanwhile, the thickness of plaque on the appliance ranged from 101 μm to 653 μm. CLSM revealed both dead and vital bacteria on the surface of the dental plaque. In addition, SEM revealed layers of various bacterial aggregations in all dental plaques.Conclusion: This study offers a potent non-invasive tool to evaluate and assess the dental plaque biofilm, which is a very important factor in the development of dental caries.

  4. Plasmons and Electrons as Nanosecond-Fast Sensors for Scanning Tunneling Microscopy

    Science.gov (United States)

    Loth, Sebastian

    2014-03-01

    The ability to measure the fast dynamical evolution of atomic-scale systems often holds the key to their understanding. We combine fast pump-probe spectroscopy tools with low-temperature scanning tunneling microscopy to study atomically assembled arrays of magnetic atoms. The dynamical information quantifies spin lifetimes, magnetic stability and even allows identifying the cross-over between quantum spins and classical magnetism. The spin relaxation times of transition metal atoms can be measured by all-electronic pump probe spectroscopy in which nanosecond-fast voltage pulses excite the spins and probe the average time-dependent response by variations in the spin-polarized tunnel current. In addition, the fast evolution of the local electrostatic potential can be mapped by detecting plasmonic light emission from the STM tunnel junction with time correlating single photon counting. The combination of electrical stimulus and optical detection provides precise control of the excitation process of individual atoms enabling new experiments to probe charge and spin dynamics in the scanning tunneling microscope.

  5. Autoregressive linear least square single scanning electron microscope image signal-to-noise ratio estimation.

    Science.gov (United States)

    Sim, Kok Swee; NorHisham, Syafiq

    2016-11-01

    A technique based on linear Least Squares Regression (LSR) model is applied to estimate signal-to-noise ratio (SNR) of scanning electron microscope (SEM) images. In order to test the accuracy of this technique on SNR estimation, a number of SEM images are initially corrupted with white noise. The autocorrelation function (ACF) of the original and the corrupted SEM images are formed to serve as the reference point to estimate the SNR value of the corrupted image. The LSR technique is then compared with the previous three existing techniques known as nearest neighbourhood, first-order interpolation, and the combination of both nearest neighborhood and first-order interpolation. The actual and the estimated SNR values of all these techniques are then calculated for comparison purpose. It is shown that the LSR technique is able to attain the highest accuracy compared to the other three existing techniques as the absolute difference between the actual and the estimated SNR value is relatively small. SCANNING 38:771-782, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  6. Snow crystal imaging using scanning electron microscopy: III. Glacier ice, snow and biota

    Science.gov (United States)

    Rango, A.; Wergin, W.P.; Erbe, E.F.; Josberger, E.G.

    2000-01-01

    Low-temperature scanning electron microscopy (SEM) was used to observe metamorphosed snow, glacial firn, and glacial ice obtained from South Cascade Glacier in Washington State, USA. Biotic samples consisting of algae (Chlamydomonas nivalis) and ice worms (a species of oligochaetes) were also collected and imaged. In the field, the snow and biological samples were mounted on copper plates, cooled in liquid nitrogen, and stored in dry shipping containers which maintain a temperature of -196??C. The firn and glacier ice samples were obtained by extracting horizontal ice cores, 8 mm in diameter, at different levels from larger standard glaciological (vertical) ice cores 7.5 cm in diameter. These samples were cooled in liquid nitrogen and placed in cryotubes, were stored in the same dry shipping container, and sent to the SEM facility. In the laboratory, the samples were sputter coated with platinum and imaged by a low-temperature SEM. To image the firn and glacier ice samples, the cores were fractured in liquid nitrogen, attached to a specimen holder, and then imaged. While light microscope images of snow and ice are difficult to interpret because of internal reflection and refraction, the SEM images provide a clear and unique view of the surface of the samples because they are generated from electrons emitted or reflected only from the surface of the sample. In addition, the SEM has a great depth of field with a wide range of magnifying capabilities. The resulting images clearly show the individual grains of the seasonal snowpack and the bonding between the snow grains. Images of firn show individual ice crystals, the bonding between the crystals, and connected air spaces. Images of glacier ice show a crystal structure on a scale of 1-2 mm which is considerably smaller than the expected crystal size. Microscopic air bubbles, less than 15 ??m in diameter, clearly marked the boundaries between these crystal-like features. The life forms associated with the glacier were

  7. External morphogenesis of the tardigrade Hypsibius dujardini as revealed by scanning electron microscopy.

    Science.gov (United States)

    Gross, Vladimir; Minich, Irene; Mayer, Georg

    2017-04-01

    Tardigrada, commonly called water bears, is a taxon of microscopic panarthropods with five-segmented bodies and four pairs of walking legs. Although tardigrades have been known to science for several centuries, questions remain regarding many aspects of their biology, such as embryogenesis. Herein, we used scanning electron microscopy to document the external changes that occur during embryonic development in the tardigrade Hypsibius dujardini (Eutardigrada, Parachela, Hypsibiidae). Our results show an accelerated development of external features, with approximately 30 hrs separating the point at which external structures first become recognizable and a fully formed embryo. All segments appear to arise simultaneously between ∼20 and 25 hrs of development, and no differences in the degree of development could be detected between the limb buds at any stage. Claws emerge shortly after the limb buds and are morphologically similar to those of adults. The origin of the claws is concurrent with that of the sclerotized parts of the mouth, suggesting that all cuticular structures arise simultaneously at ∼30 hrs. The mouth arises as an invagination in the terminal region of the head at ∼25 hrs, closes later in development, and opens again shortly before hatching. The anlagen of the peribuccal lobes arise as one dorsal and one ventral row, each consisting of three lobes, and later form a ring in the late embryo, whereas there is no indication of a labrum anlage at any point during development. Furthermore, we describe limited postembryonic development in the form of cuticular pores that are absent in juveniles but present in adults. This study represents the first scanning electron micrographs of tardigrade embryos, demonstrating the utility of this technique for studying embryogenesis in tardigrades. This work further adds an external morphological perspective to the developmental data already available for H. dujardini, facilitating future comparisons to related

  8. Use of scanning electron microscopy to monitor nanofibre/cell interaction in digestive epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Millaku, Agron, E-mail: agron.mi@hotmail.com [Limnos-Company for Applied Ecology Ltd, Podlimbarskega 31, 1000 Ljubljana (Slovenia); Drobne, Damjana [University of Ljubljana, Biotechnical Faculty, Department of Biology, Večna pot 111, 1000 Ljubljana (Slovenia); Centre of Excellence, Advanced Materials and Technologies for the Future (CO NAMASTE), Jamova cesta 39, 1000 Ljubljana (Slovenia); Centre of Excellence, Nanoscience and Nanotechnology (Nanocentre), Jamova cesta 39, 1000 Ljubljana (Slovenia); Torkar, Matjaz [Institute of Metals and Technology IMT, Lepi pot 11, 1000 Ljubljana (Slovenia); Jožef Stefan Institute, Condensed Matter Physics Department, Jamova cesta 39, 1000 Ljubljana (Slovenia); Novak, Sara [University of Ljubljana, Biotechnical Faculty, Department of Biology, Večna pot 111, 1000 Ljubljana (Slovenia); Remškar, Maja [Jožef Stefan Institute, Condensed Matter Physics Department, Jamova cesta 39, 1000 Ljubljana (Slovenia); Pipan-Tkalec, Živa [University of Ljubljana, Biotechnical Faculty, Department of Biology, Večna pot 111, 1000 Ljubljana (Slovenia)

    2013-09-15

    Graphical abstract: Scanning electron microscopy is particularly well suited to the observation of nanofibre/cell interaction in the endothelial cells lining the hepatopancreas. (a) Tungsten oxide nanofibres, (b) test organism Porcellio scaber and schematic appearance of digestive tubes, (c) digestive tube (hepatopancreas) prepared for SEM investigation, (d) digestive gland cells (C) with nanofibres (NF) embedded in the cell membrane and (e) nanofibres inserted deeply in the cells and damaged nanofibres due to peristalsis. -- Highlights: • Tungsten oxide nanofibres react physically with digestive gland epithelial cells in Porcellio scaber. • Physical peristaltic forces of lead to insertion of nanofibres into the cells. • No toxic responses as measured by conventional toxicity biomarkers were detected. • Physical interactions were observed in a majority of the investigated animals. -- Abstract: We provide data obtained by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) on the interaction of ingested tungsten nanofibers with epithelial cells of the digestive tubes of a test organism Porcellio scaber. Conventional toxicity endpoints including feeding behaviour, weight loss and mortality were also measured in each investigated animal. No toxicity was detected in any of exposed animals after 14 days of feeding on tungsten nanofiber dosed food, but when nanofibers enter the digestive system they can react with epithelial cells of the digestive tubes, becoming physically inserted into the cells. In this way, nanofibers can injure the epithelial cells of digestive gland tubes when they are ingested with food. Our SEM data suggest that peristaltic forces may have an important role, not predicted by in vitro experiments, in the interactions of nanomaterials with digestive intestinal cells.

  9. Correlative scanning electron and confocal microscopy imaging of labeled cells coated by indium-tin-oxide

    KAUST Repository

    Rodighiero, Simona

    2015-03-22

    Confocal microscopy imaging of cells allows to visualize the presence of specific antigens by using fluorescent tags or fluorescent proteins, with resolution of few hundreds of nanometers, providing their localization in a large field-of-view and the understanding of their cellular function. Conversely, in scanning electron microscopy (SEM), the surface morphology of cells is imaged down to nanometer scale using secondary electrons. Combining both imaging techniques have brought to the correlative light and electron microscopy, contributing to investigate the existing relationships between biological surface structures and functions. Furthermore, in SEM, backscattered electrons (BSE) can image local compositional differences, like those due to nanosized gold particles labeling cellular surface antigens. To perform SEM imaging of cells, they could be grown on conducting substrates, but obtaining images of limited quality. Alternatively, they could be rendered electrically conductive, coating them with a thin metal layer. However, when BSE are collected to detect gold-labeled surface antigens, heavy metals cannot be used as coating material, as they would mask the BSE signal produced by the markers. Cell surface could be then coated with a thin layer of chromium, but this results in a loss of conductivity due to the fast chromium oxidation, if the samples come in contact with air. In order to overcome these major limitations, a thin layer of indium-tin-oxide was deposited by ion-sputtering on gold-decorated HeLa cells and neurons. Indium-tin-oxide was able to provide stable electrical conductivity and preservation of the BSE signal coming from the gold-conjugated markers. © 2015 Wiley Periodicals, Inc.

  10. Correlative scanning electron and confocal microscopy imaging of labeled cells coated by indium-tin-oxide.

    Science.gov (United States)

    Rodighiero, Simona; Torre, Bruno; Sogne, Elisa; Ruffilli, Roberta; Cagnoli, Cinzia; Francolini, Maura; Di Fabrizio, Enzo; Falqui, Andrea

    2015-06-01

    Confocal microscopy imaging of cells allows to visualize the presence of specific antigens by using fluorescent tags or fluorescent proteins, with resolution of few hundreds of nanometers, providing their localization in a large field-of-view and the understanding of their cellular function. Conversely, in scanning electron microscopy (SEM), the surface morphology of cells is imaged down to nanometer scale using secondary electrons. Combining both imaging techniques have brought to the correlative light and electron microscopy, contributing to investigate the existing relationships between biological surface structures and functions. Furthermore, in SEM, backscattered electrons (BSE) can image local compositional differences, like those due to nanosized gold particles labeling cellular surface antigens. To perform SEM imaging of cells, they could be grown on conducting substrates, but obtaining images of limited quality. Alternatively, they could be rendered electrically conductive, coating them with a thin metal layer. However, when BSE are collected to detect gold-labeled surface antigens, heavy metals cannot be used as coating material, as they would mask the BSE signal produced by the markers. Cell surface could be then coated with a thin layer of chromium, but this results in a loss of conductivity due to the fast chromium oxidation, if the samples come in contact with air. In order to overcome these major limitations, a thin layer of indium-tin-oxide was deposited by ion-sputtering on gold-decorated HeLa cells and neurons. Indium-tin-oxide was able to provide stable electrical conductivity and preservation of the BSE signal coming from the gold-conjugated markers. © 2015 Wiley Periodicals, Inc.

  11. The study of the modes of Ta-Zr powder mixture non-vacuum electron-beam cladding on the surface of the cp-titanium plates

    Science.gov (United States)

    Samoylenko, V. V.; Lozhkina, E. A.; Polyakov, I. A.; Lenivtseva, O. G.; Ivanchik, I. S.; Matts, O. E.

    2016-11-01

    The effect of the modes of non-vacuum electron-beam cladding of Ta-Zr powder mixtures on the structure and properties of the layers formed on the surface of cp-titanium were studied. The mode of the electron-beam alloying of titanium with zirconium and tantalum, which ensured the formation of a defect-free layer with a high content of alloying elements was selected. Metallographic examination indicated the presence of a dendritic- and plate-type structure of cladded layers. The microhardness of the layers, formed at the optimum mode, was not changed in the cross section and was equal to 450 HV.

  12. Direct Visualization of Local Electromagnetic Field Structures by Scanning Transmission Electron Microscopy.

    Science.gov (United States)

    Shibata, Naoya; Findlay, Scott D; Matsumoto, Takao; Kohno, Yuji; Seki, Takehito; Sánchez-Santolino, Gabriel; Ikuhara, Yuichi

    2017-07-18

    The functional properties of materials and devices are critically determined by the electromagnetic field structures formed inside them, especially at nanointerface and surface regions, because such structures are strongly associated with the dynamics of electrons, holes and ions. To understand the fundamental origin of many exotic properties in modern materials and devices, it is essential to directly characterize local electromagnetic field structures at such defect regions, even down to atomic dimensions. In recent years, rapid progress in the development of high-speed area detectors for aberration-corrected scanning transmission electron microscopy (STEM) with sub-angstrom spatial resolution has opened new possibilities to directly image such electromagnetic field structures at very high-resolution. In this Account, we give an overview of our recent development of differential phase contrast (DPC) microscopy for aberration-corrected STEM and its application to many materials problems. In recent years, we have developed segmented-type STEM detectors which divide the detector plane into 16 segments and enable simultaneous imaging of 16 STEM images which are sensitive to the positions and angles of transmitted/scattered electrons on the detector plane. These detectors also have atomic-resolution imaging capability. Using these segmented-type STEM detectors, we show DPC STEM imaging to be a very powerful tool for directly imaging local electromagnetic field structures in materials and devices in real space. For example, DPC STEM can clearly visualize the local electric field variation due to the abrupt potential change across a p-n junction in a GaAs semiconductor, which cannot be observed by normal in-focus bright-field or annular type dark-field STEM imaging modes. DPC STEM is also very effective for imaging magnetic field structures in magnetic materials, such as magnetic domains and skyrmions. Moreover, real-time imaging of electromagnetic field structures can

  13. Dark field imaging of biological macromolecules with the scanning transmission electron microscope

    Science.gov (United States)

    Ohtsuki, Mitsuo; Isaacson, Michael S.; Crewe, A. V.

    1979-01-01

    A scanning transmission electron microscope (STEM) equipped with a field emission gun has been employed for the examination of biological macromolecules at high resolution. The quality of micrographs obtained with the STEM is dependent upon the quality of the substrate used to support biological objects because the image contrast in dark field is proportional to the mass density of the specimen. In order to reduce deleterious effects of the substrates on the image quality, we have developed a method of fabricating substrates consisting of very thin, very clean carbon films supported on very clean fenestrated plastic films. These films are approximately 15 Å thick. Well-known biological macromolecules such as glutamine synthetase and tobacco mosaic virus (both stained) and low-density lipoprotein and ferritin (both unstained were placed on these substrates and examined with the STEM by using various modes of contrast. The micrographs obtained by using the dark field mode of contrast employing an annular detector were free from phase contrast, as expected. Using this contrast mode, we have been able to directly observe (in-focus) 2.5- to 4.4-Å lattice spacings in the ferritin core. The effect of electron radiation damage on the helical structure of tobacco mosaic virus was also examined. Micrographs as well as corresponding optical diffraction patterns obtained with moderately low doses showed very clear helical structure from both sides of the virus. In addition, the (11.5 Å)-1 layer lines indicated the effective resolution attained on these particles. Images PMID:35788

  14. Orientation mapping of nanostructured materials using transmission Kikuchi diffraction in the scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Trimby, Patrick W., E-mail: patrick.trimby@sydney.edu.au [Australian Centre for Microscopy and Microanalysis, The University of Sydney, Madsen Building F09 Sydney, NSW 2006 (Australia)

    2012-09-15

    In this study, the new technique of transmission Kikuchi diffraction (TKD) in the scanning electron microscope (SEM) has been applied for the first time to enable orientation mapping of bulk, nanostructured metals. The results show how the improved spatial resolution of SEM-TKD, compared to conventional EBSD, enables reliable mapping of truly nanostructured metals and alloys, with mean grain sizes in the 40-200 nm range. The spatial resolution of the technique is significantly below 10 nm, and contrasting examples are shown from both dense (Ni) and lighter (Al-alloy) materials. Despite the burden of preparing thin, electron-transparent samples, orientation mapping using SEM-TKD is likely to become invaluable for routine characterisation of nanocrystalline and, potentially, highly deformed microstructures. -- Highlights: Black-Right-Pointing-Pointer First report of orientation mapping by transmission Kikuchi diffraction in the SEM. Black-Right-Pointing-Pointer The SEM-TKD technique can achieve an effective spatial resolution of 2-4 nm. Black-Right-Pointing-Pointer Nanostructured Ni with a mean grain size of <50 nm has been effectively mapped. Black-Right-Pointing-Pointer Highly deformed Al-alloy, with sub-200 nm grains, has also been characterized. Black-Right-Pointing-Pointer The sample thickness is critical for effective results: ideally 75-200 nm for Al.

  15. Advanced scanning transmission stereo electron microscopy of structural and functional engineering materials.

    Science.gov (United States)

    Agudo Jácome, L; Eggeler, G; Dlouhý, A

    2012-11-01

    Stereo transmission electron microscopy (TEM) provides a 3D impression of the microstructure in a thin TEM foil. It allows to perform depth and TEM foil thickness measurements and to decide whether a microstructural feature lies inside of a thin foil or on its surface. It allows appreciating the true three-dimensional nature of dislocation configurations. In the present study we first review some basic elements of classical stereo TEM. We then show how the method can be extended by working in the scanning transmission electron microscope (STEM) mode of a modern analytical 200 kV TEM equipped with a field emission gun (FEG TEM) and a high angle annular dark field (HAADF) detector. We combine two micrographs of a stereo pair into one anaglyph. When viewed with special colored glasses the anaglyph provides a direct and realistic 3D impression of the microstructure. Three examples are provided which demonstrate the potential of this extended stereo TEM technique: a single crystal Ni-base superalloy, a 9% Chromium tempered martensite ferritic steel and a NiTi shape memory alloy. We consider the effect of camera length, show how foil thicknesses can be measured, and discuss the depth of focus and surface effects. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. The use of field emission scanning electron microscopy to assess recombinant adenovirus stability.

    Science.gov (United States)

    Obenauer-Kutner, Linda J; Ihnat, Peter M; Yang, Tong-Yuan; Dovey-Hartman, Barbara J; Balu, Arthi; Cullen, Constance; Bordens, Ronald W; Grace, Michael J

    2002-09-20

    A field emission scanning electron microscopy (FESEM) method was developed to assess the stability of a recombinant adenovirus (rAd). This method was designed to simultaneously sort, count, and size the total number of rAd viral species observed within an image field. To test the method, a preparation of p53 transgene-expressing recombinant adenovirus (rAd/p53) was incubated at 37 degrees C and the viral particles were evaluated by number, structure, and degree of aggregation as a function of time. Transmission electron microscopy (TEM) was also used to obtain ultrastructural detail. In addition, the infectious activity of the incubated rAd/p53 samples was determined using flow cytometry. FESEM image-analysis revealed that incubation at 37 degrees C resulted in a time-dependent decrease in the total number of detectable single rAd/p53 virus particles and an increase in apparent aggregates composed of more than three adenovirus particles. There was also an observed decrease in both the diameter and perimeter of the single rAd/p53 viral particles. TEM further revealed the accumulation of damaged single particles with time at 37 degrees C. The results of this study demonstrate that FESEM, coupled with sophisticated image analysis, may be an important tool in quantifying the distribution of aggregated species and assessing the overall stability of rAd samples.

  17. Cryo-field emission scanning electron microscopy imaging of a rigid surfactant mesophase.

    Science.gov (United States)

    Tan, Grace; Xu, Peng; John, Vijay T; He, Jibao; McPherson, Gary L; Agarwal, Vivek; Bose, Arijit

    2008-10-07

    The aerosol OT/ L-alpha-phosphatidylcholine/isooctane/water system forms a rigid mesophase that transitions from reverse hexagonal to multilamellar in structure at specific water contents. This study shows that characteristics of ordered liquid-crystalline mesophases can be distinguished and imaged in high clarity using cryo-field emission scanning electron microscopy (cryo-FESEM). The reverse hexagonal phase consists of bundles of long cylinders, some with length scales of over 2 microm, that are randomly oriented as part of a larger domain. Cryo-imaging allows the visualization of the intercylinder spacings and the details of transitions from one domain to another. The multilamellar structured mesophase consists of spherical vesicles of 100 nm to 10 microm in diameter, with intervening noncrystalline isotropic regions. Coexistence regions containing both the reverse hexagonal and lamellar structures are also observed in the transition from the reverse hexagonal to the lamellar phase. These results complement and qualitatively verify our earlier studies with small-angle neutron scattering, high-field nuclear magnetic resonance spectroscopy, and freeze-fracture direct imaging transmission electron microscopy. The information is useful in understanding materials templating in these rigid systems.

  18. Immunogold labeling of amelogenin in developing porcine enamel revealed by field emission scanning electron microscopy.

    Science.gov (United States)

    Du, Chang; Fan, Daming; Sun, Zhi; Fan, Yuwei; Lakshminarayanan, Rajamani; Moradian-Oldak, Janet

    2009-01-01

    The present study describes a method using immunohistochemical labeling in combination with high-resolution imaging (field emission scanning electron microscopy) to investigate the spatial localization of amelogenins on apatite crystallites in developing porcine enamel. Cross-sections of developing enamel tissue from freeze-fractured pig third molar were treated with antiserum against recombinant mouse amelogenin and immunoreactivity confirmed by Western blot analysis. The samples were then treated with the goat anti-rabbit IgG conjugated with 10-nm gold particles. The control samples were treated with the secondary antibody only. The in-lens secondary electrons detector and quadrant back-scattering detector were employed to reveal the high-resolution morphology of enamel structures and gold particle distribution. The immunolabeling showed a preference of the gold particle localization along the side faces of the ribbon-like apatite crystals. The preferential localization of amelogenin in vivo on enamel crystals strongly supports its direct function in controlling crystal morphology. Copyright 2008 S. Karger AG, Basel.

  19. Correlative microscopy of Purkinje dendritic spines: a field emission scanning and transmission electron microscopic study.

    Science.gov (United States)

    Castejón, O J; Castellano, A; Arismendi, G; Apkarian, R

    2004-01-01

    Purkinje dendritic spines (Pds) of mouse cerebellar cortex were examined by field emission scanning electron microscopy (FESEM) and by transmission electron microscopy (TEM) using ultrathin sections and freeze-etching replicas, to study their three-dimensional features and intramembrane morphology. FESEM showed unattached mushroom-type, elongated and lanceolate Pds separated by 100-500 nm on the dendritic shaft surface. High resolution FESEM showed 25-50 nm globular subunits at the spine postsynaptic density corresponding to the localization of postsynaptic proteins and/or postsynaptic receptors. TEM images of ultrathin sections showed gem-like, mushroom-shaped, lanceolate and neckless or stubby spines. Freeze etching replicas exposed postsynaptic intramembrane particles that can be correlated with the globular subunits observed at high resolution FESEM. Parallel and climbing fiber endings were observed making asymmetric synaptic contacts with the Pds heads. Simultaneous contacts with the necks and heads were also found. The variety of Pds shapes were interpreted as spine conformational changes related with spine dynamic, and spine plasticity.

  20. Evaluation of the infection process by Lecanicillium fungicola in Agaricus bisporus by scanning electron microscopy.

    Science.gov (United States)

    Santana Nunes, Janaira; Rocha de Brito, Manuela; Cunha Zied, Diego; Aparecida das Graças Leite, Eloisa; Souza Dias, Eustáquio; Alves, Eduardo

    Lecanicillium fungicola causes dry bubble disease in Agaricus bisporus mushrooms leading to significant economic losses in commercial production. To monitor the infection process of L. fungicola in Brazilian strains of A. bisporus. The interaction between the mycelium of L. fungicola (LF.1) and three strains of A. bisporus (ABI 7, ABI 11/14 and ABI 11/21) was studied. Electron microscopy and X-ray microanalyses of vegetative growth and basidiocarp infection were evaluated. Micrographs show that the vegetative mycelium of the Brazilian strains of A. bisporus is not infected by the parasite. The images show that the pathogen can interlace the hyphae of A. bisporus without causing damage, which contributes to the presence of L. fungicola during the substrate colonization, allowing their presence during primordial formation of A. bisporus. In the basidiocarp, germ tubes form within 16h of infection with L. fungicola and the beginning of penetration takes place within 18h, both without the formation of specialized structures. Scanning electron microscopy enabled the process of colonization and reproduction to be observed within the formation of phialides, conidiophores and verticils of L. fungicola. The formation of calcium oxalate crystals by the pathogen was also visible using the X-ray microanalysis, both at the hyphae in the Petri plate and at basidiocarp infection site. Copyright © 2016 Asociación Española de Micología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Mapping Carrier Dynamics on Material Surfaces in Space and Time using Scanning Ultrafast Electron Microscopy

    KAUST Repository

    Sun, Jingya

    2016-02-25

    Selectively capturing the ultrafast dynamics of charge carriers on materials surfaces and at interfaces is crucial to the design of solar cells and optoelectronic devices. Despite extensive research efforts over the past few decades, information and understanding about surface-dynamical processes, including carrier trapping and recombination remains extremely limited. A key challenge is to selectively map such dynamic processes, a capability that is hitherto impractical by time-resolved laser techniques, which are limited by the laser’s relatively large penetration depth and consequently they record mainly bulk information. Such surface dynamics can only be mapped in real space and time by applying four-dimensional (4D) scanning ultrafast electron microscopy (S-UEM), which records snapshots of materials surfaces with nanometer spatial and sub-picosecond temporal resolutions. In this method, the secondary electron (SE) signal emitted from the sample’s surface is extremely sensitive to the surface dynamics and is detected in real time. In several unique applications, we spatially and temporally visualize the SE energy gain and loss, the charge carrier dynamics on the surface of InGaN nanowires and CdSe single crystals and its powder film. We also provide the mechanisms for the observed dynamics, which will be the foundation for future potential applications of S-UEM to a wide range of studies on material surfaces and device interfaces.

  2. Joint denoising and distortion correction of atomic scale scanning transmission electron microscopy images

    Science.gov (United States)

    Berkels, Benjamin; Wirth, Benedikt

    2017-09-01

    Nowadays, modern electron microscopes deliver images at atomic scale. The precise atomic structure encodes information about material properties. Thus, an important ingredient in the image analysis is to locate the centers of the atoms shown in micrographs as precisely as possible. Here, we consider scanning transmission electron microscopy (STEM), which acquires data in a rastering pattern, pixel by pixel. Due to this rastering combined with the magnification to atomic scale, movements of the specimen even at the nanometer scale lead to random image distortions that make precise atom localization difficult. Given a series of STEM images, we derive a Bayesian method that jointly estimates the distortion in each image and reconstructs the underlying atomic grid of the material by fitting the atom bumps with suitable bump functions. The resulting highly non-convex minimization problems are solved numerically with a trust region approach. Existence of minimizers and the model behavior for faster and faster rastering are investigated using variational techniques. The performance of the method is finally evaluated on both synthetic and real experimental data.

  3. Novel scanning electron microscopy methods for analyzing the 3D structure of the Golgi apparatus.

    Science.gov (United States)

    Koga, Daisuke; Ushiki, Tatsuo; Watanabe, Tsuyoshi

    2017-01-01

    The structure of the Golgi apparatus has been extensively examined by light and electron microscopy, but details of its three-dimensional (3D) structure have remained unclear because of the technical limitations of conventional microscopy techniques. To overcome this problem, we have developed several novel scanning electron microscopy (SEM) methods for observing the 3D structure of subcellular organelles including the Golgi apparatus: (1) an osmium maceration method that facilitates SEM observation of membranous organelles, including the Golgi apparatus, by selectively removing soluble cytoplasmic proteins, (2) an osmium impregnation/maceration method that combines an osmium impregnation method with the osmium maceration method to determine the polarity of the Golgi apparatus by SEM, (3) a correlative light and SEM method that combines a cryosectioning technique with the osmium maceration method to enable correlation of the immunocytochemical distribution of molecules with the 3D ultrastructure of the Golgi apparatus, and (4) array tomography based on the systematic collection and integration of SEM images of serial ultrathin sections on glass slides for revealing the 3D ultrastructure of the entire Golgi apparatus. Together, the novel SEM techniques listed above can reveal the complete 3D structure of the Golgi apparatus in different cell types.

  4. Hygroscopic analysis of individual Beijing haze aerosol particles by environmental scanning electron microscopy

    Science.gov (United States)

    Bai, Zhangpeng; Ji, Yuan; Pi, Yiqun; Yang, Kaixiang; Wang, Li; Zhang, Yinqi; Zhai, Yadi; Yan, Zhengguang; Han, Xiaodong

    2018-01-01

    Investigating the hygroscopic behavior of haze aerosol particles is essential for understanding their physicochemical properties and their impacts on regional weather and visibility. An environmental scanning electron microscope equipped with a home-made transmission-scattering electron imaging setup and an energy dispersive spectrometer was used for in-situ observations of pure water-soluble (WS) salts and Beijing haze particles. This imaging setup showed obvious advantages for improving the resolution and acquiring internal information of mixed particles in hydrated environments. We measured the deliquescence relative humidity of pure NaCl, NH4NO3, and (NH4)2SO4 by deliquescence-crystallization processes with an accuracy of up to 0.3% RH. The mixed haze particles showed hygroscopic activation like water uptake and morphological changes when they included WS components such as nitrates, sulfates, halides, ammoniums, and alkali metal salts. In addition, the hygroscopic behavior provides complementary information for analyzing possible phases in mixed haze particles.

  5. In situ observation of water in a fuel cell catalyst using scanning electron microscopy.

    Science.gov (United States)

    Ueda, Satoru; Kobayashi, Yoshio; Koizumi, Satoshi; Tsutsumi, Yasuyuki

    2015-04-01

    To visualize water in the catalyst of polymer electrolyte fuel cells (PEFCs), backscattered electron (BSE) imaging by means of scanning electron microscopy was employed. To confine a wet specimen of catalyst, an environmental wet cell was manufactured with a silicon nitride thin film (∼100 nm) as the beam window. By supplying humidified gas into the cell, a change in BSE brightness was detected in the catalyst attached to the silicon nitride window. As humidification proceeded, the BSE image became darker and returned brighter by switching to a dry gas. Monte Carlo simulations were performed to evaluate the energy and number of BSE obtained after passing through water with thickness d. Combining the results of the Monte Carlo simulation successfully converted the change in brightness to the change in thickness from d = 100 nm to d = 3 μm. This established method of evaluating water with a thickness resolution of the order of Δd = 100 nm can be applied to in situ observations of the catalyst in a PEFC during operation. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Scanning transmission electron microscopy: Albert Crewe's vision and beyond

    Energy Technology Data Exchange (ETDEWEB)

    Krivanek, Ondrej L., E-mail: krivanek@nion.com [Nion Company, 1102 8th Street, Kirkland, WA 98033 (United States); Chisholm, Matthew F. [Oak Ridge National Laboratory, Materials Science and Technology Division, Oak Ridge, TN 37831-6069 (United States); Murfitt, Matthew F.; Dellby, Niklas [Nion Company, 1102 8th Street, Kirkland, WA 98033 (United States)

    2012-12-15

    Some four decades were needed to catch up with the vision that Albert Crewe and his group had for the scanning transmission electron microscope (STEM) in the nineteen sixties and seventies: attaining 0.5 A resolution, and identifying single atoms spectroscopically. With these goals now attained, STEM developments are turning toward new directions, such as rapid atomic resolution imaging and exploring atomic bonding and electronic properties of samples at atomic resolution. The accomplishments and the future challenges are reviewed and illustrated with practical examples. -- Highlights: Black-Right-Pointing-Pointer TV-rate STEM imaging of heavy atoms is demonstrated. Black-Right-Pointing-Pointer DNA sequencing by STEM dark field imaging should be possible at a rate of 10{sup 6} bases/s. Black-Right-Pointing-Pointer Individual silicon atom impurities in graphene are imaged atom-by-atom. Black-Right-Pointing-Pointer Single atoms of nitrogen and boron incorporated in graphene are imaged spectroscopically. Black-Right-Pointing-Pointer Bonding of individual atoms can be probed by analyzing the fine structures of their EEL spectra.

  7. Video-frequency scanning transmission electron microscopy of moving gold nanoparticles in liquid.

    Science.gov (United States)

    Ring, Elisabeth A; de Jonge, Niels

    2012-11-01

    Immobilized gold nanoparticles were imaged in a liquid containing water and 50% glycerol with scanning transmission electron microscopy (STEM). The specimen was enclosed in a liquid compartment formed by two silicon microchips with electron transparent windows. A series of images was recorded at video frequency with a spatial resolution of 1.5nm. The nanoparticles detached from their support after imaging them for several seconds at a magnification of 250,000. Their movement was found to be much different than the movement of nanoparticles moving freely in liquid as described by Brownian Motion. The direction of motion was not random-the nanoparticles moved either in a preferred direction, or radially outwards from the center of the image. The displacement of the gold nanoparticles over time was three orders of magnitude smaller than expected on the basis of Brownian Motion. This finding implies that nanoscale objects of flexible structure or freely floating, including nanoparticles and biological objects, can be imaged with nanoscale resolution, as long as they are in close proximity to a solid support structure. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Immunogold scanning electron microscopy can reveal the polysaccharide architecture of xylem cell walls.

    Science.gov (United States)

    Sun, Qiang; Sun, Yuliang; Juzenas, Kevin

    2017-04-01

    Immunofluorescence microscopy (IFM) and immunogold transmission electron microscopy (TEM) are the two main techniques commonly used to detect polysaccharides in plant cell walls. Both are important in localizing cell wall polysaccharides, but both have major limitations, such as low resolution in IFM and restricted sample size for immunogold TEM. In this study, we have developed a robust technique that combines immunocytochemistry with scanning electron microscopy (SEM) to study cell wall polysaccharide architecture in xylem cells at high resolution over large areas of sample. Using multiple cell wall monoclonal antibodies (mAbs), this immunogold SEM technique reliably localized groups of hemicellulosic and pectic polysaccharides in the cell walls of five different xylem structures (vessel elements, fibers, axial and ray parenchyma cells, and tyloses). This demonstrates its important advantages over the other two methods for studying cell wall polysaccharide composition and distribution in these structures. In addition, it can show the three-dimensional distribution of a polysaccharide group in the vessel lateral wall and the polysaccharide components in the cell wall of developing tyloses. This technique, therefore, should be valuable for understanding the cell wall polysaccharide composition, architecture and functions of diverse cell types. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  9. Nano-Tomography of Porous Geological Materials Using Focused Ion Beam-Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2016-10-01

    Full Text Available Tomographic analysis using focused ion beam-scanning electron microscopy (FIB-SEM provides three-dimensional information about solid materials with a resolution of a few nanometres and thus bridges the gap between X-ray and transmission electron microscopic tomography techniques. This contribution serves as an introduction and overview of FIB-SEM tomography applied to porous materials. Using two different porous Earth materials, a diatomite specimen, and an experimentally produced amorphous silica layer on olivine, we discuss the experimental setup of FIB-SEM tomography. We then focus on image processing procedures, including image alignment, correction, and segmentation to finally result in a three-dimensional, quantified pore network representation of the two example materials. To each image processing step we consider potential issues, such as imaging the back of pore walls, and the generation of image artefacts through the application of processing algorithms. We conclude that there is no single image processing recipe; processing steps need to be decided on a case-by-case study.

  10. Cell organelles at uncoated cryofractured surfaces as viewed with the scanning electron microscope.

    Science.gov (United States)

    Woods, P S; Ledbetter, M C

    1976-06-01

    A method of direct visualization of cell organelles by scanning electron microscopy (SEM) is described. Plant and animal tissues fixed in glutaraldehyde and osmium tetroxide are treated with the ligand thiocarbohydrazide and a second osmium tetroxide solution, to increase their osmium content. Tissues are then dehydrated, infiltrated with an epoxy monomer, and together solidified with dry ice and fractured. The pieces are transferred to pure acetone, critical-point dried, attached to stubs with silver paint and viewed by SEM. The ligating procedure increases the osmium concentration at its original bonding site sufficiently to render the tissue electrically conductive, thus obviating the need for metallic coating. he organelles at the fractured surface are revaled in relation to their osmium incorporation rather than by surface irregularities as with coating methods. The image derived from the uncoated surface approaches in resolution that of transmission electron micrographs of thin sections. A protion of the image arising from a small distance below the surface, while at progressively lower resolution, provides some 3-dimensional information about cell fine structure.

  11. Study of skin of an Egyptian mummy using a scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Mańkowska-Pliszka Hanna

    2017-06-01

    Full Text Available The first study of modified human remains using an electron microscope was carried out at the end of the 1950 and in 1979 the first result of the study involving a scanning electron microscope (SEM was published for the first time. The study was mainly focused on the structure of tissues and cells. With the help of this technique cell and tissue elements, viruses and bacterial endospores as well as the structure of epithelium and the collagen contents of dermis were identified and described. In the above-mentioned case the object of the study using a SEM was a free part of the right hand (forearm with the dorsal and palmar parts of hand of unknown origin, with signs of mummification revealed during microscopic analysis. Our study was aimed at finding the answer to the question if the mummification of the studied limb was natural or intentional, and if the study using a SEM could link the anonymous remains with ancient Egypt.

  12. Poor electronic screening in lightly doped Mott insulators observed with scanning tunneling microscopy

    Science.gov (United States)

    Battisti, I.; Fedoseev, V.; Bastiaans, K. M.; de la Torre, A.; Perry, R. S.; Baumberger, F.; Allan, M. P.

    2017-06-01

    The effective Mott gap measured by scanning tunneling microscopy (STM) in the lightly doped Mott insulator (Sr1-xLax) 2IrO4 differs greatly from values reported by photoemission and optical experiments. Here we show that this is a consequence of the poor electronic screening of the tip-induced electric field in this material. Such effects are well known from STM experiments on semiconductors and go under the name of tip-induced band bending (TIBB). We show that this phenomenon also exists in the lightly doped Mott insulator (Sr1-xLax) 2IrO4 and that, at doping concentrations of x ≤4 % , it causes the measured energy gap in the sample density of states to be bigger than the one measured with other techniques. We develop a model able to retrieve the intrinsic energy gap leading to a value which is in rough agreement with other experiments, bridging the apparent contradiction. At doping x ≈5 % we further observe circular features in the conductance layers that point to the emergence of a significant density of free carriers in this doping range and to the presence of a small concentration of donor atoms. We illustrate the importance of considering the presence of TIBB when doing STM experiments on correlated-electron systems and discuss the similarities and differences between STM measurements on semiconductors and lightly doped Mott insulators.

  13. Can X-ray spectrum imaging replace backscattered electrons for compositional contrast in the scanning electron microscope?

    Science.gov (United States)

    Newbury, Dale E; Ritchie, Nicholas W M

    2011-01-01

    The high throughput of the silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS) enables X-ray spectrum imaging (XSI) in the scanning electron microscope to be performed in frame times of 10-100 s, the typical time needed to record a high-quality backscattered electron (BSE) image. These short-duration XSIs can reveal all elements, except H, He, and Li, present as major constituents, defined as 0.1 mass fraction (10 wt%) or higher, as well as minor constituents in the range 0.01-0.1 mass fraction, depending on the particular composition and possible interferences. Although BSEs have a greater abundance by a factor of 100 compared with characteristic X-rays, the strong compositional contrast in element-specific X-ray maps enables XSI mapping to compete with BSE imaging to reveal compositional features. Differences in the fraction of the interaction volume sampled by the BSE and X-ray signals lead to more delocalization of the X-ray signal at abrupt compositional boundaries, resulting in poorer spatial resolution. Improved resolution in X-ray elemental maps occurs for the case of a small feature composed of intermediate to high atomic number elements embedded in a matrix of lower atomic number elements. XSI imaging strongly complements BSE imaging, and the SDD-EDS technology enables an efficient combined BSE-XSI measurement strategy that maximizes the compositional information. If 10 s or more are available for the measurement of an area of interest, the analyst should always record the combined BSE-XSI information to gain the advantages of both measures of compositional contrast. Copyright © 2011 Wiley Periodicals, Inc.

  14. Ultrastructural study of polyspermy during early embryo development in pigs, observed by scanning electron microscope and transmission electron microscope.

    Science.gov (United States)

    Xia, P; Wang, Z; Yang, Z; Tan, J; Qin, P

    2001-02-01

    Polyspermy is generally considered a pathological phenomenon in mammals. Incidence of polyspermy in porcine eggs in vivo is extremely high (30-40%) compared with other species, and polyspermy rate in the in vitro fertilized eggs in pigs can reach 65%. It is still unknown whether polyspermy to a certain degree is a physiological condition in pigs, and whether porcine eggs have any capability with which to remove the accessory sperm in the cytoplasm. The objectives in the present study are to observe the ultrastructural changes of accessory sperm during early embryonic development in pigs. A total of 58 normal, early embryos at one-, two, three-, and four-cell and morular stages were collected from gilts and were studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The surface ultrastructure showed that sperm fusion with the zona pellucida was a continuous process during one-, two-, three-, and four-cell and morular stages, as observed by the SEM. Accessory sperm were present in the cytoplasm of cleaved embryos. The sperm heads in the cytoplasm of cleaved embryos did not decondense. TEM revealed the presence of a condensed sperm head within a lysosome (or phagolysosome) in a three-cell embryo. These observations suggest that polyspermy may be a physiological condition in pigs and that early embryos may develop to term if accessory sperm do not interrupt the embryo genome. Furthermore, lysosome activity could be another physiological mechanism for removing accessory sperm in the cytoplasm of fertilized eggs and cleaved embryos after fertilization in pigs.

  15. Analysis of Facial Implants for Bacterial Biofilm Formation Using Scanning Electron Microscopy.

    Science.gov (United States)

    Walker, Thomas J; Toriumi, Dean M

    2016-07-01

    Alloplastic implants are widely used in facial plastic surgery, both in rhinoplasty and nonrhinoplasty procedures. Implant infection and extrusion are significant concerns of such implants after placement. Bacterial biofilms have been previously implicated in chronic wound infections, particularly in the presence of foreign bodies, such as alloplastic facial implants. Owing to their structural composition, biofilms are resistant to treatment with conventional antibiotics, and implant removal is frequently the only option. To evaluate explanted alloplastic facial implants for the presence or absence of bacterial biofilm using scanning electron microscopy. Facial implants explanted by a single surgeon were analyzed for biofilm formation between July 1, 2012, and June 30, 2013. Of 7 facial implants, 4 consisted of silicone, and 3 were porous polyethylene. Six of the 7 were nasal dorsal implants, and 1 silicone implant was removed from the midface. Nonexplanted fresh silicone and porous polyethylene implants were each used as a control. Scanning electron microscopy images were analyzed by an electron microscopist masked to the clinical history and implant type. The presence of biofilm formation was graded as none, mild, moderate, or severe. A total of 7 patients with previously placed alloplastic facial implants at an outside institution underwent revision rhinoplasty and removal of facial implants. All porous polyethylene implants showed biofilm formation to various degrees. Furthermore, all porous polyethylene implants had at least some areas of severe biofilm formation. One of the 3 porous polyethylene implants demonstrated severe biofilm formation on the entire implant, and the other 2 porous polyethylene implants showed areas of mild and severe biofilm formation. The only 2 implants without any evidence of biofilm were silicone implants. Of the other 2 silicone implants, 1 demonstrated no biofilm formation in 1 area and severe biofilm formation in another area

  16. Low energy electron diffraction (LEED) and sum frequency generation (SFG) vibrational spectroscopy studies of solid-vacuum, solid-air and solid-liquid interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, Saskia [Univ. of California, Berkeley, CA (United States)

    2002-01-01

    Electron based surface probing techniques can provide detailed information about surface structure or chemical composition in vacuum environments. The development of new surface techniques has made possible in situ molecular level studies of solid-gas interfaces and more recently, solid-liquid interfaces. The aim of this dissertation is two-fold. First, by using novel sample preparation, Low Energy Electron Diffraction (LEED) and other traditional ultra high vacuum (UHV) techniques are shown to provide new information on the insulator/vacuum interface. The surface structure of the classic insulator NaCl has been determined using these methods. Second, using sum frequency generation (SFG) surface specific vibrational spectroscopy studies were performed on both the biopolymer/air and electrode/electrolyte interfaces. The surface structure and composition of polyetherurethane-silicone copolymers were determined in air using SFG, atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). SFG studies of the electrode (platinum, gold and copper)/electrolyte interface were performed as a function of applied potential in an electrochemical cell.

  17. Is scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) quantitative?

    Science.gov (United States)

    Newbury, Dale E; Ritchie, Nicholas W M

    2013-01-01

    Scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) is a widely applied elemental microanalysis method capable of identifying and quantifying all elements in the periodic table except H, He, and Li. By following the "k-ratio" (unknown/standard) measurement protocol development for electron-excited wavelength dispersive spectrometry (WDS), SEM/EDS can achieve accuracy and precision equivalent to WDS and at substantially lower electron dose, even when severe X-ray peak overlaps occur, provided sufficient counts are recorded. Achieving this level of performance is now much more practical with the advent of the high-throughput silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS). However, three measurement issues continue to diminish the impact of SEM/EDS: (1) In the qualitative analysis (i.e., element identification) that must precede quantitative analysis, at least some current and many legacy software systems are vulnerable to occasional misidentification of major constituent peaks, with the frequency of misidentifications rising significantly for minor and trace constituents. (2) The use of standardless analysis, which is subject to much broader systematic errors, leads to quantitative results that, while useful, do not have sufficient accuracy to solve critical problems, e.g. determining the formula of a compound. (3) EDS spectrometers have such a large volume of acceptance that apparently credible spectra can be obtained from specimens with complex topography that introduce uncontrolled geometric factors that modify X-ray generation and propagation, resulting in very large systematic errors, often a factor of ten or more. © Wiley Periodicals, Inc.

  18. Aberration-corrected scanning transmission electron microscopy for complex transition metal oxides

    Science.gov (United States)

    Qing-Hua, Zhang; Dong-Dong, Xiao; Lin, Gu

    2016-06-01

    Lattice, charge, orbital, and spin are the four fundamental degrees of freedom in condensed matter, of which the interactive coupling derives tremendous novel physical phenomena, such as high-temperature superconductivity (high-T c SC) and colossal magnetoresistance (CMR) in strongly correlated electronic system. Direct experimental observation of these freedoms is essential to understanding the structure-property relationship and the physics behind it, and also indispensable for designing new materials and devices. Scanning transmission electron microscopy (STEM) integrating multiple techniques of structure imaging and spectrum analysis, is a comprehensive platform for providing structural, chemical and electronic information of materials with a high spatial resolution. Benefiting from the development of aberration correctors, STEM has taken a big breakthrough towards sub-angstrom resolution in last decade and always steps forward to improve the capability of material characterization; many improvements have been achieved in recent years, thereby giving an in-depth insight into material research. Here, we present a brief review of the recent advances of STEM by some representative examples of perovskite transition metal oxides; atomic-scale mapping of ferroelectric polarization, octahedral distortions and rotations, valence state, coordination and spin ordering are presented. We expect that this brief introduction about the current capability of STEM could facilitate the understanding of the relationship between functional properties and these fundamental degrees of freedom in complex oxides. Project supported by the National Key Basic Research Project, China (Grant No. 2014CB921002), the Strategic Priority Research Program of Chinese Academy of Sciences (Grant No. XDB07030200), and the National Natural Science Foundation of China (Grant Nos. 51522212 and 51421002).

  19. STEMsalabim: A high-performance computing cluster friendly code for scanning transmission electron microscopy image simulations of thin specimens.

    Science.gov (United States)

    Oelerich, Jan Oliver; Duschek, Lennart; Belz, Jürgen; Beyer, Andreas; Baranovskii, Sergei D; Volz, Kerstin

    2017-06-01

    We present a new multislice code for the computer simulation of scanning transmission electron microscope (STEM) images based on the frozen lattice approximation. Unlike existing software packages, the code is optimized to perform well on highly parallelized computing clusters, combining distributed and shared memory architectures. This enables efficient calculation of large lateral scanning areas of the specimen within the frozen lattice approximation and fine-grained sweeps of parameter space. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Comparison of macroscopic and microscopic (stereomicroscopy and scanning electron microscopy) features of bone lesions due to hatchet hacking trauma.

    Science.gov (United States)

    Nogueira, Luísa; Quatrehomme, Gérald; Bertrand, Marie-France; Rallon, Christophe; Ceinos, Romain; du Jardin, Philippe; Adalian, Pascal; Alunni, Véronique

    2017-03-01

    This experimental study examined the lesions produced by a hatchet on human bones (tibiae). A total of 30 lesions were produced and examined macroscopically (naked eye) and by stereomicroscopy. 13 of them were also analyzed using scanning electron microscopy. The general shape of the lesion, both edges, both walls, the kerf floor and the extremities were described. The length and maximum width of the lesions were also recorded. The microscopic analysis of the lesions led to the description of a sharp-blunt mechanism. Specific criteria were identified (lateral pushing back, fragmentation of the upraising, fossa dug laterally to the edge and vertical striae) enabling the forensic expert to conclude that a hacking instrument was used. These criteria are easily identifiable using scanning electron microscopy, but can also be observed with stereomicroscopy. Overall, lateral pushing back and vertical striae visible using stereomicroscopy and scanning electron microscopy signal the use of a hacking tool.

  1. Performance assessment of methods for estimation of fractal dimension from scanning electron microscope images.

    Science.gov (United States)

    Risović, Dubravko; Pavlović, Zivko

    2013-01-01

    Processing of gray scale images in order to determine the corresponding fractal dimension is very important due to widespread use of imaging technologies and application of fractal analysis in many areas of science, technology, and medicine. To this end, many methods for estimation of fractal dimension from gray scale images have been developed and routinely used. Unfortunately different methods (dimension estimators) often yield significantly different results in a manner that makes interpretation difficult. Here, we report results of comparative assessment of performance of several most frequently used algorithms/methods for estimation of fractal dimension. To that purpose, we have used scanning electron microscope images of aluminum oxide surfaces with different fractal dimensions. The performance of algorithms/methods was evaluated using the statistical Z-score approach. The differences between performances of six various methods are discussed and further compared with results obtained by electrochemical impedance spectroscopy on the same samples. The analysis of results shows that the performance of investigated algorithms varies considerably and that systematically erroneous fractal dimensions could be estimated using certain methods. The differential cube counting, triangulation, and box counting algorithms showed satisfactory performance in the whole investigated range of fractal dimensions. Difference statistic is proved to be less reliable generating 4% of unsatisfactory results. The performances of the Power spectrum, Partitioning and EIS were unsatisfactory in 29%, 38%, and 75% of estimations, respectively. The results of this study should be useful and provide guidelines to researchers using/attempting fractal analysis of images obtained by scanning microscopy or atomic force microscopy. © Wiley Periodicals, Inc.

  2. VACUUM TRAP

    Science.gov (United States)

    Gordon, H.S.

    1959-09-15

    An improved adsorption vacuum trap for use in vacuum systems was designed. The distinguishing feature is the placement of a plurality of torsionally deformed metallic fins within a vacuum jacket extending from the walls to the central axis so that substantially all gas molecules pass through the jacket will impinge upon the fin surfaces. T fins are heated by direct metallic conduction, thereby ol taining a uniform temperature at the adeorbing surfaces so that essentially all of the condensible impurities from the evacuating gas are removed from the vacuum system.

  3. Electropolymerized nanoporous polymeric SPME coatings: preparation and characterization by small angle X-ray scattering and scanning electron microscopy.

    Science.gov (United States)

    Buszewski, Boguslaw; Olszowy, Pawel; Pikus, Stanislaw; Kozak, Maciej

    Polymeric polypyrrole and polythiophene solid phase microextraction (SPME) coatings were prepared using electropolymerization with a linear sweep voltammetry technique. Physicochemical properties were measured using different methods, in particular small angle X-ray scattering and scanning electron microscopy. By using innovative approaches for pore size measurement, we were able to calculate a maximum of the pore size range from 80 to 90 nm. Additionally, film thicknesses measured from 90 to 150 μm. Using scanning electron microscopy, we describe the characteristics of polymer growth on the support surface.

  4. Validation of cell-free culture using scanning electron microscopy (SEM) and gene expression studies.

    Science.gov (United States)

    Yang, R; Elankumaran, Y; Hijjawi, N; Ryan, U

    2015-06-01

    A cell-free culture system for Cryptosporidium parvum was analysed using scanning electron microscopy (SEM) to characterise life cycle stages and compare gene expression in cell-free culture and cell culture using HCT-8 cells. Cryptosporidium parvum samples were harvested at 2 h, 8 h, 14 h, 26 h, 50 h, 74 h, 98 h, 122 h and 170 h, chemically fixed and specimens were observed using a Zeiss 1555 scanning electron microscope. The presence of sporozoites, trophozoites and type I merozoites were identified by SEM. Gene expression in cell culture and cell-free culture was studied using reverse transcriptase quantitative PCR (RT-qPCR) of the sporozoite surface antigen protein (cp15), the glycoprotein 900 (gp900), the Cryptosporidium oocyst wall protein (COWP) and 18S ribosomal RNA (rRNA) genes in both cell free and conventional cell culture. In cell culture, cp15 expression peaked at 74 h, gp900 expression peaked at 74 h and 98 h and COWP expression peaked at 50 h. In cell-free culture, CP15 expression peaked at 98 h, gp900 expression peaked at 74 h and COWP expression peaked at 122 h. The present study is the first to compare gene expression of C. parvum in cell culture and cell-free culture and to characterise life cycle stages of C. parvum in cell-free culture using SEM. Findings from this study showed that gene expression patterns in cell culture and cell-free culture were similar but in cell-free culture, gene expression was delayed for CP15 and COWP in cell free culture compared with the cell culture system and was lower. Although three life cycle stageswere conclusively identified, improvements in SEM methodology should lead to the detection of more life cycle stages. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. The importance of scanning electron microscopy (sem in taxonomy and morphology of Chironomidae (Diptera

    Directory of Open Access Journals (Sweden)

    Andrzej Kownacki

    2015-07-01

    Full Text Available The paper reports on the value of scanning electron microscopy (SEM in the taxonomy and morphology of Chironomidae. This method has been relatively rarely used in Chironomidae studies. Our studies suggest that the SEM method provides a lot of new information. For example, the plastron plate of the thoracic horn of Macropelopia nebulosa (Meigen under light microscopy is visible as points, while under SEM we have found that it consists of a reticular structure with holes. By using SEM a more precise picture of the body structure of Chironomidae can be revealed. It allows researchers to explain inconsistencies in the existing descriptions of species. Another advantage of the SEM method is obtaining spatial images of the body and organs of Chironomidae. However, the SEM method also has some limitations. The main problem is dirt or debris (e.g. algae, mud, secretions, mucus, bacteria, etc., which often settles on the external surface of structures, especially those which are uneven or covered with hair. The dirt should be removed after collection of chironomid material because if left in place it can become chemically fixed to various surfaces. It unnecessarily remains at the surface and final microscopic images may contain artifacts that obscure chironomid structures being investigated. In this way many details of the surface are thus unreadable. The results reported here indicate that SEM examination helps us to identify new morphological features and details that will facilitate the identification of species of Chironomidae and may help to clarify the function of various parts of the body. Fast development of electron microscope technique allows us to learn more about structure of different organisms.

  6. Interfacial reactions of glasses for biomedical application by scanning transmission electron microscopy and microanalysis.

    Science.gov (United States)

    Banchet, V; Michel, J; Jallot, E; Wortham, L; Bouthors, S; Laurent-Maquin, D; Balossier, G

    2006-05-01

    Short-term physico-chemical reactions at the interface between bioactive glass particles and biological fluids are studied for three glasses with different bioactive properties; these glasses are in the SiO(2)-Na(2)O-CaO-P(2)O(5)-K(2)O-Al(2)O(3)-MgO system. Our aim is to show the difference between the mechanisms of their surface reactions. The relation between the composition and the bioactive properties of these glasses is also discussed. The elemental analysis is performed at the submicrometer scale by scanning transmission electron microscopy associated with energy-dispersive X-ray spectroscopy and electron energy loss spectroscopy. After different immersion times (ranging from 0 to 96 h) of bioactive glass particles in a simulated biological solution, results show the formation of different surface layers at the glass periphery in the case of two bioactive glasses (A9 and BVA). For the third glass (BVH) we do not observe any surface layer formation or any modification of the glass composition. For the two other glasses (A9 and BVA), we observe the presence of different layers: an already observed (Si, O, Al) rich layer at the periphery, a previously demonstrated thin (Si, O) layer formed on top of the (Si, O, Al) layer and a (Ca, P) layer. We determine the different steps of the mechanisms of the surface reactions, which appear to be similar in these glasses, and compare the physico-chemical reactions and kinetics using the different immersion times. The A9 glass permits the observation of all important steps of the surface reactions which lead to bioactivity. This study shows the important relationship between composition and bioactivity which can determine the medical applicability of the glass.

  7. An optimized methodology to analyze biopolymer capsules by environmental scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Conforto, Egle, E-mail: egle.conforto@univ-lr.fr [LaSIE UMR 7356 CNRS-ULR, Université de La Rochelle, UFR Sciences, Avenue Michel Crepeau, 17042 La Rochelle (France); Joguet, Nicolas [Equipe Approches Moléculaires Environnement-Santé, LIENSs, UMR 7266 CNRS-ULR, Université de La Rochelle, UFR Sciences, Avenue Michel Crepeau, 17042 La Rochelle (France); Buisson, Pierre [INNOV' IA, 4 rue Samuel Champlain, Z.I. Chef de Baie, 17000 La Rochelle (France); Vendeville, Jean-Eudes; Chaigneau, Carine [IDCAPS, filiale R and D INNOV' IA, 4 rue Samuel Champlain, Z.I. Chef de Baie, 17000 La Rochelle (France); Maugard, Thierry [Equipe Approches Moléculaires Environnement-Santé, LIENSs, UMR 7266 CNRS-ULR, Université de La Rochelle, UFR Sciences, Avenue Michel Crepeau, 17042 La Rochelle (France)

    2015-02-01

    The aim of this paper is to describe an optimized methodology to study the surface characteristics and internal structure of biopolymer capsules using scanning electron microscopy (SEM) in environmental mode. The main advantage of this methodology is that no preparation is required and, significantly, no metallic coverage is deposited on the surface of the specimen, thus preserving the original capsule shape and its surface morphology. This avoids introducing preparation artefacts which could modify the capsule surface and mask information concerning important feature like porosities or roughness. Using this method gelatin and mainly fatty coatings, difficult to be analyzed by standard SEM technique, unambiguously show fine details of their surface morphology without damage. Furthermore, chemical contrast is preserved in backscattered electron images of unprepared samples, allowing visualizing the internal organization of the capsule, the quality of the envelope, etc.… This study provides pointers on how to obtain optimal conditions for the analysis of biological or sensitive material, as this is not always studied using appropriate techniques. A reliable evaluation of the parameters used in capsule elaboration for research and industrial applications, as well as that of capsule functionality is provided by this methodology, which is essential for the technological progress in this domain. - Highlights: • We optimized a methodology using ESEM to analyze biopolymer capsules. • This methodology allows analyzing original surface samples without any preparation. • No preparation artefact are introduced which would mask important surface details. • Morphological details and chemical contrast from the original surface are preserved. • Capsule shape, volume, surface roughness and coating quality were reliably evaluated.

  8. Scanning electron microscope technique for measuring electrical conductivity: application to tetrathiafulvalene--tetracyanoquinodimethane

    Energy Technology Data Exchange (ETDEWEB)

    Long, James Peter [Univ. of Illinois, Urbana-Champaign, IL (United States)

    1977-01-01

    A new technique for measuring the electrical conductivity of small samples and its application to the organic conductor tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ) is reported. A movable current source provided by the electron beam of a scanning electron microscope is used to map out the potential distribution on crystal faces containing the a-b crystallographic axes. Silver paint contacts are used to return the beam current to ground and measure voltage changes as the beam position is moved. The results of the new technique are confirmed and complemented by the conventional movable contact method and the extension of both methods to low temperature is discussed. The potential distributions for our samples reveal frequently occurring irregularities in current flow which are attributable to sample imperfections and inhomogeneities in the silver paint contacts. Methods are presented whereby the commonly reported conductivities sigmaa and sigmab can be determined despite the presence of certain current flow irrgularities; room temperature values are found to be: sigmab = 490 ± 80 (Ωcm)-1 and sigmaa = 1.21 ± 0.15 (Ωcm)-1. The relationship of sigmaa/ and sigmab to the elements of the correctly expressed conductivity tensor for TTF-TCNQ is clarified. The influence of contact inhomogeneities on four-probe measurements of the temperature dependence of the b-axis conductivity as determined with an electrolytic tank model are also presented. It is found that there is a large probability of slightly underestimating conductivity, but that it is possible in a small number of cases to greatly overestimate conductivity.

  9. Cytoarchitecture of the normal rat olfactory epithelium: light and scanning electron microscopic studies.

    Science.gov (United States)

    Nomura, Tomoyuki; Takahashi, Sugata; Ushiki, Tatsuo

    2004-06-01

    The three-dimensional cytoarchitecture of the normal rat olfactory epithelium was examined by scanning electron microscopy (SEM) of KOH digested tissues as well as by light and transmission electron microscopy of plastic sections. Observations specimens from the lateral side of the olfactory epithelium allowed identification of four cell types by their surface structure: olfactory neurons, supporting cells, basal cells, and duct cells of the Bowman's gland. The olfactory neurons were characterized by the presence of a thick apical process (i.e., dendrite) and a thin basal process (i.e., axon). These olfactory neurons tended to be aligned along the vertical axis of the epithelium. Immature olfactory neurons were present at the basal part of the epithelium and had a pear-shaped cell body with a thin and long axon and a short dendrite which failed to reach the epithelial surface. Supporting cells were roughly columnar in shape and occupied the full length of the epithelium. They became thinner in the basal two thirds of their length but had branched foot processes spreading on the basal surface of the epithelium. Basal cells located in the basal epithelial region were oval, round or cuboidal and present among the foot processes of the supporting cells. The ducts of the Bowman's gland entered the epithelium from the lamina propria and took straight, perpendicular courses within the epithelium. These intraepithelial ducts were composed of several slender cells. The acinar cells are sometimes present in the epithelium and appeared as a globular bulge of the duct at the basal part of the epithelium. SEM observation of the basal surface of the olfactory epithelium also clearly showed that axon bundles were surrounded by the sheet-like processes of Schwann cells, the investment being found at the base of the epithelium just before axon bundles leave the epithelium.

  10. Cleaning graphene: Comparing heat treatments in air and in vacuum

    Science.gov (United States)

    Tripathi, Mukesh; Mittelberger, Andreas; Mustonen, Kimmo; Mangler, Clemens; Kotakoski, Jani; Meyer, Jannik C.; Susi, Toma

    2017-08-01

    Surface impurities and contamination often seriously degrade the properties of two-dimensional materials such as graphene. To remove contamination, thermal annealing is commonly used. We present a comparative analysis of annealing treatments in air and in vacuum, both ex situ and "pre-situ", where an ultra-high vacuum treatment chamber is directly connected to an aberration-corrected scanning transmission electron microscope. While ex situ treatments do remove contamination, it is challenging to obtain atomically clean surfaces after ambient transfer. However, pre-situ cleaning with radiative or laser heating appears reliable and well suited to clean graphene without undue damage to its structure.

  11. Thromboembolic ischemic stroke and the presence of necrotic platelets: a scanning electron microscopy investigation.

    Science.gov (United States)

    Pretorius, Etheresia; Engelbrecht, Mia-Jeanne; Duim, Wiebren

    2012-02-01

    Stroke is one of the most debilitating diseases worldwide, with its occurrence increasing in Western societies. Central to the pathogenesis of thromboembolic stroke is the involvement of platelets. During thromboembolic events, nucleated cells undergo cell death, and platelets are also affected by parameters causing these incidents. Particularly, initiation of necrotic cell death at sites of vascular injury may play an important role in inducing inflammatory and repair processes. In the current research, the authors investigate whether a changed platelet ultrastructure is visible in thromboembolic stroke and whether it might be visible in platelets as apoptosis or necrosis. Therefore, in the current investigation, the authors study smears of platelet-rich plasma (PRP) from thromboembolic ischemic stroke patients to investigate whether a changed morphology is visible in distressed platelets. Scanning electron microscopy is used and platelets are viewed at up to 200,000× machine magnification. Results indicate that thromboembolic ischemic stroke causes membrane tears and swollen platelets, and this is indicative of necrosis. It is therefore concluded that this morphology might be due to the pro-coagulant activity characteristic of the disease.

  12. Reissner's fibre in the rat: a scanning and transmission electron microscope study.

    Science.gov (United States)

    Woollam, D H; Collins, P

    1980-01-01

    The structure and connexions of Reissner's fibre have been studied in the rat by means of scanning and transmission electron microscopy. The fibre was found to arise from a series of filaments, each of which was formed by a structure forming the juxta-aqueductal surface or lining of the subcommissural organ. This structure was termed 'apical spherical protrusion' and was found to be rich in rough endoplasmic reticulum. The fibre was firmly attached at its rostral end to the subcommissural organ, at its middle to the ventral surface of the termination of the aqueduct and finally to the calamus scriptorius of the fourth ventricle. It was held in a state of considerable tension between these three points and attached to it were numerous cilia from the ependymal lining. In sections examined by TEM the fibre appeared to be totally amorphous in structure, with erythrocytes and other debris attached to it. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 PMID:7440397

  13. Mass mapping of a protein complex with the scanning transmission electron microscope.

    Science.gov (United States)

    Engel, A; Baumeister, W; Saxton, W O

    1982-01-01

    A mass map of the hexagonally packed intermediate layer (HPI-layer), a regular protein monolayer from the cell envelope of Micrococcus radiodurans, has been obtained by scanning transmission electron microscopy. Samples were freeze-dried within the microscope, and low-dose images were recorded in the dark-field mode directly in digital form and processed by correlation averaging. The averaged projection of the unstained structure--i.e., the mass map--thus calculated shows a resolution to 3-nm period and reveals morphological features consistent with those obtained by negative staining. The mass of individual morphological domains was extracted by using variously the mass map itself or an average from a negatively stained HPI layer to define the domain boundaries. Protrusions as small as 1,300 daltons could be measured reproducibly within the unit cell of 655,000 daltons. The method developed opens an avenue to identify molecular species in situ and to correlate topographic information with biochemical data. Images PMID:6955791

  14. Profile and Morphology of Fungal Aerosols Characterized by Field Emission Scanning Electron Microscopy (FESEM).

    Science.gov (United States)

    Afanou, Komlavi Anani; Straumfors, Anne; Skogstad, Asbjørn; Skaar, Ida; Hjeljord, Linda; Skare, Øivind; Green, Brett James; Tronsmo, Arne; Eduard, Wijnand

    Fungal aerosols consist of spores and fragments with diverse array of morphologies; however, the size, shape, and origin of the constituents require further characterization. In this study, we characterize the profile of aerosols generated from Aspergillus fumigatus, A. versicolor, and Penicillium chrysogenum grown for 8 weeks on gypsum boards. Fungal particles were aerosolized at 12 and 20 L min-1 using the Fungal Spore Source Strength Tester (FSSST) and the Stami particle generator (SPG). Collected particles were analyzed with field emission scanning electron microscopy (FESEM). We observed spore particle fraction consisting of single spores and spore aggregates in four size categories, and a fragment fraction that contained submicronic fragments and three size categories of larger fragments. Single spores dominated the aerosols from A. fumigatus (median: 53%), while the submicronic fragment fraction was the highest in the aerosols collected from A. versicolor (median: 34%) and P. chrysogenum (median: 31%). Morphological characteristics showed near spherical particles that were only single spores, oblong particles that comprise some spore aggregates and fragments (3.5 μm). Further, the near spherical particles dominated the aerosols from A. fumigatus (median: 53%), while oblong particles were dominant in the aerosols from A. versicolor (68%) and P. chrysogenum (55%). Fiber-like particles represented 21% and 24% of the aerosols from A. versicolor and P. chrysogenum, respectively. This study shows that fungal particles of various size, shape, and origin are aerosolized, and supports the need to include a broader range of particle types in fungal exposure assessment.

  15. Ion milling coupled field emission scanning electron microscopy reveals current misunderstanding of morphology of polymeric nanoparticles.

    Science.gov (United States)

    Francis, Donny; Mouftah, Samiha; Steffen, Robert; Beduneau, Arnaud; Pellequer, Yann; Lamprecht, Alf

    2015-01-01

    Nanoparticles (NPs) are currently used as drug delivery systems for numerous therapeutic macromolecules, e.g. proteins or DNA. Based on the preparation by double emulsion solvent evaporation a sponge-like structure was postulated entrapping hydrophilic drugs inside an internal aqueous phase. However, a direct proof of this hypothesized structure is still missing today. NPs were prepared from different polymers using a double-emulsion method and characterized for their physicochemical properties. Combining ion milling with field emission scanning electron microscopy allowed to cross section single NP and to visualize their internal morphology. The imaging procedure permitted cross-sectioning of NPs and visualization of the internal structure as well as localizing drugs associated with NPs. It was observed that none of the model actives was encapsulated inside the polymeric matrix when particle diameters were below around 470 nm but predominantly adsorbed to the particle surface. Even at larger diameters only a minority of particles of a diameter below 1 μm contained an internal phase. The properties of such drug loaded NPs, i.e. drug release or the observations in cellular uptake or even drug targeting needs to be interpreted carefully since in most cases NP surface properties are potentially dominated by the 'encapsulated' drug characteristics. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Microbe repelling coated stainless steel analysed by field emission scanning electron microscopy and physicochemical methods.

    Science.gov (United States)

    Raulio, Mari; Järn, Mikael; Ahola, Juhana; Peltonen, Jouko; Rosenholm, Jarl B; Tervakangas, Sanna; Kolehmainen, Jukka; Ruokolainen, Timo; Narko, Pekka; Salkinoja-Salonen, Mirja

    2008-07-01

    Coating of stainless steel with diamond-like carbon or certain fluoropolymers reduced or almost eliminated adhesion and biofilm growth of Staphylococcus epidermidis, Deinococcus geothermalis, Meiothermus silvanus and Pseudoxanthomonas taiwanensis. These species are known to be pertinent biofilm formers on medical implants or in the wet-end of paper machines. Field emission scanning electron microscopic analysis showed that Staph. epidermidis, D. geothermalis and M. silvanus grew on stainless steel using thread-like organelles for adhesion and biofilm formation. The adhesion threads were fewer in number on fluoropolymer-coated steel than on plain steel and absent when the same strains were grown in liquid culture. Psx. taiwanensis adhered to the same surfaces by a mechanism involving cell ghosts on which the biofilm of live cells grew. Hydrophilic (diamond-like carbon) or hydrophobic (fluoropolymer) coatings reduced the adherence of the four test bacteria on different steels. Selected topographic parameters, including root-mean-square roughness (S (q)), skewness (S (sk)) and surface kurtosis (S (ku)), were analysed by atomic force microscopy. The surfaces that best repelled microbial adhesion of the tested bacteria had higher skewness values than those only slightly repelling. Water contact angle, measured (theta (m)) or roughness corrected (theta (y)), affected the tendency for biofilm growth in a different manner for the four test bacteria.

  17. Indirect Immunodetection of Fungal Fragments by Field Emission Scanning Electron Microscopy.

    Science.gov (United States)

    Afanou, Komlavi Anani; Straumfors, Anne; Skogstad, Asbjørn; Nayak, Ajay P; Skaar, Ida; Hjeljord, Linda; Tronsmo, Arne; Eduard, Wijnand; Green, Brett James

    2015-09-01

    Submicronic fungal fragments have been observed in in vitro aerosolization experiments. The occurrence of these particles has therefore been suggested to contribute to respiratory health problems observed in mold-contaminated indoor environments. However, the role of submicronic fragments in exacerbating adverse health effects has remained unclear due to limitations associated with detection methods. In the present study, we report the development of an indirect immunodetection assay that utilizes chicken polyclonal antibodies developed against spores from Aspergillus versicolor and high-resolution field emission scanning electron microscopy (FESEM). Immunolabeling was performed with A. versicolor fragments immobilized and fixed onto poly-l-lysine-coated polycarbonate filters. Ninety percent of submicronic fragments and 1- to 2-μm fragments, compared to 100% of >2-μm fragments generated from pure freeze-dried mycelial fragments of A. versicolor, were positively labeled. In proof-of-concept experiments, air samples collected from moldy indoor environments were evaluated using the immunolabeling technique. Our results indicated that 13% of the total collected particles were derived from fungi. This fraction comprises 79% of the fragments that were detected by immunolabeling and 21% of the spore particles that were morphologically identified. The methods reported in this study enable the enumeration of fungal particles, including submicronic fragments, in a complex heterogeneous environmental sample. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  18. Evaluation of an automated system for root canal irrigation: a scanning electron microscopy study.

    Science.gov (United States)

    Mattioli-Belmonte, Monica; Orsini, Giovanna; Giuliodori, Francesca; DI Cristoforo, Adriano; Procaccini, Maurizio; Mengucci, Paolo; Putignano, Angelo

    2012-01-01

    This study evaluated a new automated system using alternative irrigants for root canal cleaning treatments. This method relies on a system inserting an enzymatic solution based on Trypsin flowing inside the pulp chambers and root canals, completely avoiding traditional endodontic instrumentation. Sixty freshly extracted human molar teeth were randomly divided into 4 groups to assess 3 regimens (R1-3) differing in 0.25% Trypsin/EDTA and 5% Sodium Hypochlorite (NaOCl) solutions administration. Scanning electron microscopy observations and scores taking into account changes in dentin tubules were used to assess treatment effects in pulp chambers and roots. Significant changes in root cleaning ability relative to administration timing were observed, with the best results found in R3, with scheduled alternated cycles of Trypsin/EDTA and NaOCl inside the tooth. The non-invasive root canal method demonstrates good teeth cleaning ability independent of root morphology. This equipment may provide lower discomfort levels for patients undergoing endodontic treatment.

  19. Scanning electron microscopy of the attachment of Treponema pallidum to nerve cells in vitro.

    Science.gov (United States)

    Repesh, L A; Fitzgerald, T J; Oakes, S G; Pozos, R S

    1982-01-01

    Treponema pallidum (Nichols strain) was incubated with cultured nerve cells derived from rat embryos. Primary cultures were established from dorsal root ganglia, superior cervical ganglia, and spinal cord. Using phase contrast microscopy treponemes were seen to interact with the nerve cells in a similar manner to other cultured mammalian cells. Organisms began to attach within minutes after inoculation, actively motile organisms attached at the tip of one end, higher numbers of organisms attached with continued incubation, and attached organisms survived longer than unattached organisms. T pallidum attached both to nerve cell bodies and to neuronal processes of each of the three nerve cell cultures. As shown by scanning electron microscopy the mechanism of attachment was identical to that of cultured cells derived from rabbits testis, rat skeletal muscle, and human cervical carcinoma. There was no indentation or swelling of the cultured cell surface at the point of attachment, just a close physical proximity of organisms and cells. These techniques provide a biological means of studying the in-vitro detrimental influences of micro-organisms on nerve tissue. Images PMID:7049315

  20. Antioxidant mix: A novel pulpotomy medicament: A scanning electron microscopy evaluation

    Directory of Open Access Journals (Sweden)

    M Ajay Reddy

    2014-01-01

    Full Text Available Aim: This study aims to evaluate the clinical, radiographic, and histological success rate of antioxidant mix as a new pulpotomy agent for primary teeth. Settings and Design: Commercially available antioxidants, namely Antioxidants plus trace elements (OXIn-Xt tm , India were used. Materials and Methods: This prospective study was carried out on 36 primary molar teeth in 32 children, with age that ranged from 6 to 9 years. Regular conventional pulpotomy procedure followed by placement of antioxidant mix over the radicular orifice was done. Recall was scheduled for 3, 6, and 9 months, respectively, after treatment. Results: Thirty-six pulpotomized primary molars were available for follow-up evaluations. Scanning electron microscopy analysis of samples showing convex shaped hard tissue barrier formation may be proof of the role of antioxidant material in localization and direction and morphology of the hard tissue barrier. One tooth which presented with pain was assessed as unsuccessful. Conclusion: Quite promising clinical, radiographic, and histological results of antioxidants in the present study shows their potential to be an ideal pulpotomy agent.