WorldWideScience

Sample records for vacuum electronics applications

  1. Vacuum electronics applications at CERN

    CERN Document Server

    Jensen, E

    2009-01-01

    CERN operates a large number of vacuum electronics based RF power amplifiers covering a wide frequency range – over 300 sockets with 24 different grid tubes and klystrons are in use and require constant care to insure reliable operation of the accelerators. This is in particular true for the LHC and its injector chain, for which a program of improvement and stepwise upgrade has started. These include IOT’s for the SPS and klystrons and modulators for Linac4 and SPL. The CLIC study and the CTF3 facility are relevant to vacuum electronics in many ways: The CLIC primary RF power, to be provided at 1 GHz, requires highest possible efficiency and phase stability, MBK’s are likely candidates. The CLIC RF power source and CTF3 are themselves large vacuum electronics applications, consequently there are areas of common interest and concern, including fabrication techniques, pulse compression techniques, breakdown and multipactor theory and simulation, material fatigue, numerical analysis of slow-wave structures...

  2. Vacuum electronics

    CERN Document Server

    Eichmeier, Joseph A

    2008-01-01

    Nineteen experts from the electronics industry, research institutes and universities have joined forces to prepare this book. ""Vacuum Electronics"" covers the electrophysical fundamentals, the present state of the art and applications, as well as the future prospects of microwave tubes and systems, optoelectronics vacuum devices, electron and ion beam devices, light and X-ray emitters, particle accelerators and vacuum interrupters. These topics are supplemented by useful information about the materials and technologies of vacuum electronics and vacuum technology.

  3. Application of Concentrated Electron Beams in Extra-Vacuum Technologies

    Science.gov (United States)

    Gorshkov, Oleg; Iliin, A. A.; Lovtsov, A. S.; Rizakhanov, R. N.

    2001-10-01

    At present time the rise in development of the technology with using the concentrated electron beams in gas with atmospheric pressure is observed. Besides the technologies, which are usually carried out in vacuum and connected with surface modification by the concentrated energy flows (welding, cutting, metal surface hardening), at present time the plasma chemical processes become of greater interest. These are processes with using the beam of fast electrons to initiate the plasma chemical reactions. One of such technologies is gas cleaning of the toxic impurities (nitrogen oxides and sulfur oxides and etc.) The electron-beam gas cleaning of the toxic impurities (for example Ebara-process) is based on radiation-enhanced combining of toxic impurities. The disadvantage of this method are high level of consumed power during the gas cleaning and difficulties in devices development for the output of electron beam with megawatt unit power with foil outlet, as the facilities of this very power are necessary for the real industrial application. These problems can be solved by using the devices with concentrated electron beam output into the atmosphere. In this case the beam is transported into the dense gas through the system of lock chambers, independently pumped. But unlike the beam, output through the foil window, the concentrated electron beam is characterized by the noticeable spatial irregularity in distribution of temperature, plasma concentration and area of radiation. This paper is devoted to consideration of using the concentrated electron beams in extra-vacuum technologies.

  4. Vacuum nanoelectronic devices novel electron sources and applications

    CERN Document Server

    Evtukh, Anatoliy; Yilmazoglu, Oktay; Mimura, Hidenori; Pavlidis, Dimitris

    2015-01-01

    Introducing up-to-date coverage of research in electron field emission from nanostructures, Vacuum Nanoelectronic Devices outlines the physics of quantum nanostructures, basic principles of electron field emission, and vacuum nanoelectronic devices operation, and offers as insight state-of-the-art and future researches and developments.  This book also evaluates the results of research and development of novel quantum electron sources that will determine the future development of vacuum nanoelectronics. Further to this, the influence of quantum mechanical effects on high frequency vacuum nanoelectronic devices is also assessed. Key features: In-depth description and analysis of the fundamentals of Quantum Electron effects in novel electron sources. Comprehensive and up-to-date summary of the physics and technologies for THz sources for students of physical and engineering specialties and electronics engineers. Unique coverage of quantum physical results for electron-field emission and novel electron sourc...

  5. Vacuum science, technology, and applications

    CERN Document Server

    Naik, Pramod K

    2018-01-01

    Vacuum plays an important role in science and technology. The study of interaction of charged particles, neutrals and radiation with each other and with solid surfaces requires a vacuum environment for reliable investigations. Vacuum has contributed immensely to advancements made in nuclear science, space, metallurgy, electrical/electronic technology, chemical engineering, transportation, robotics and many other fields. This book is intended to assist students, scientists, technicians and engineers to understand the basics of vacuum science and technology for application in their projects. The fundamental theories, concepts, devices, applications, and key inventions are discussed.

  6. Calculations of secondary electron yield of graphene coated copper for vacuum electronic applications

    Directory of Open Access Journals (Sweden)

    H. K. A. Nguyen

    2018-01-01

    Full Text Available The suppression of secondary electron yield (SEY which can possibly lead to multipactor is an important goal for several applications. Though some techniques have focused on geometric modifications to lower the SEY, the use of graphene coatings as thin as a few monolayers is a promising new development that deserves attention either as a standalone technique or in concert with geometric alterations. Here we report on Monte Carlo based numerical studies of SEY on graphene coated copper with comparisons to recent experimental data. Our predicted values are generally in good agreement with reported measurements. Suppression of the secondary electron yield by as much as 50 percent (over copper with graphene coating is predicted at energies below 125 eV, and bodes well for multipactor suppression in radio frequency applications.

  7. Calculations of secondary electron yield of graphene coated copper for vacuum electronic applications

    Science.gov (United States)

    Nguyen, H. K. A.; Mankowski, J.; Dickens, J. C.; Neuber, A. A.; Joshi, R. P.

    2018-01-01

    The suppression of secondary electron yield (SEY) which can possibly lead to multipactor is an important goal for several applications. Though some techniques have focused on geometric modifications to lower the SEY, the use of graphene coatings as thin as a few monolayers is a promising new development that deserves attention either as a standalone technique or in concert with geometric alterations. Here we report on Monte Carlo based numerical studies of SEY on graphene coated copper with comparisons to recent experimental data. Our predicted values are generally in good agreement with reported measurements. Suppression of the secondary electron yield by as much as 50 percent (over copper) with graphene coating is predicted at energies below 125 eV, and bodes well for multipactor suppression in radio frequency applications.

  8. Study on local vacuum electron beam welding of flange rim

    CERN Document Server

    He Cheng Dan; Ying Lei; Xu Qi Jin

    2002-01-01

    Local vacuum electron beam welding and its application prospect in military and civil industry are introduced. A home made local vacuum electron beam welding is completed. Its main technical parameters and key techniques are also presented

  9. Microscale Digital Vacuum Electronic Gates

    Science.gov (United States)

    Manohara, Harish (Inventor); Mojarradi, Mohammed M. (Inventor)

    2014-01-01

    Systems and methods in accordance with embodiments of the invention implement microscale digital vacuum electronic gates. In one embodiment, a microscale digital vacuum electronic gate includes: a microscale field emitter that can emit electrons and that is a microscale cathode; and a microscale anode; where the microscale field emitter and the microscale anode are disposed within at least a partial vacuum; where the microscale field emitter and the microscale anode are separated by a gap; and where the potential difference between the microscale field emitter and the microscale anode is controllable such that the flow of electrons between the microscale field emitter and the microscale anode is thereby controllable; where when the microscale anode receives a flow of electrons, a first logic state is defined; and where when the microscale anode does not receive a flow of electrons, a second logic state is defined.

  10. Kinetics of Evaporation of Alloying Elements under Vacuum: Application to Ti alloys in Electron Beam Melting

    Science.gov (United States)

    Choi, Wonjin; Jourdan, Julien; Matveichev, Alexey; Jardy, Alain; Bellot, Jean-Pierre

    2017-09-01

    Vacuum metallurgical processes such as the electron beam melting are highly conducive to volatilization. In titanium processing, it concerns the alloying elements which show a high vapor pressure with respect to titanium matrix, such as Al. Two different experimental approaches using a laboratory electron beam furnace have been developed for the estimation of volatilization rate and activity coefficient of Al in Ti64. The first innovative method is based on the deposition rate of Al on Si wafers located at different angles θ above the liquid bath. We found that a deposition according to a cos2(π/2-θ) law describes well the experimental distribution of the weight of the deposition layer. The second approach relies on the depletion of aluminum in the liquid pool at two separate times of the volatilization process. Both approaches provide values of the Al activity coefficient at T=1, 860 °C in a fairly narrow range [0.044-0.0495], in good agreement with the range reported in the literature. Furthermore numerical simulation of the Al behavior in the liquid pool reveals (in the specific case of electron beam button melting) a weak transport resistance in the surface boundary layer.

  11. The Dirac-Electron Vacuum Wave

    Directory of Open Access Journals (Sweden)

    Daywitt W. C.

    2016-07-01

    Full Text Available This paper argues that the Dirac equation can be interpreted as an interaction between the electron core and the Planck vacuum state, where the positive and negative solutions represent respectively the dynamics of the electron core and a vacuum wave propagating within the vacuum state. Results show that the nonrelativistic positive solution reduces to the Schrödinger wave equation

  12. Suprathermal electrons in a vacuum spark discharge

    Energy Technology Data Exchange (ETDEWEB)

    Bashutin, O. A., E-mail: boa308@mail.ru; Savjolov, A. S., E-mail: savjolov@plasma.mephi.ru [National Research Nuclear University MEPhI (Russian Federation)

    2016-04-15

    Results of experiments on the detection of suprathermal electron beams in the plasma of a highcurrent low-inductance vacuum spark by means of space-resolved spectral X-ray polarimetry are presented. It is shown that the observed polarization of bremsstrahlung may be caused by an ~100-keV electron beam propagating along the discharge axis from the pinching region toward the anode. The influence of the discharge initiation conditions on the parameters of the generated electron beams is analyzed.

  13. Recent advances in vacuum sciences and applications

    Science.gov (United States)

    Mozetič, M.; Ostrikov, K.; Ruzic, D. N.; Curreli, D.; Cvelbar, U.; Vesel, A.; Primc, G.; Leisch, M.; Jousten, K.; Malyshev, O. B.; Hendricks, J. H.; Kövér, L.; Tagliaferro, A.; Conde, O.; Silvestre, A. J.; Giapintzakis, J.; Buljan, M.; Radić, N.; Dražić, G.; Bernstorff, S.; Biederman, H.; Kylián, O.; Hanuš, J.; Miloševič, S.; Galtayries, A.; Dietrich, P.; Unger, W.; Lehocky, M.; Sedlarik, V.; Stana-Kleinschek, K.; Drmota-Petrič, A.; Pireaux, J. J.; Rogers, J. W.; Anderle, M.

    2014-04-01

    Recent advances in vacuum sciences and applications are reviewed. Novel optical interferometer cavity devices enable pressure measurements with ppm accuracy. The innovative dynamic vacuum standard allows for pressure measurements with temporal resolution of 2 ms. Vacuum issues in the construction of huge ultra-high vacuum devices worldwide are reviewed. Recent advances in surface science and thin films include new phenomena observed in electron transport near solid surfaces as well as novel results on the properties of carbon nanomaterials. Precise techniques for surface and thin-film characterization have been applied in the conservation technology of cultural heritage objects and recent advances in the characterization of biointerfaces are presented. The combination of various vacuum and atmospheric-pressure techniques enables an insight into the complex phenomena of protein and other biomolecule conformations on solid surfaces. Studying these phenomena at solid-liquid interfaces is regarded as the main issue in the development of alternative techniques for drug delivery, tissue engineering and thus the development of innovative techniques for curing cancer and cardiovascular diseases. A review on recent advances in plasma medicine is presented as well as novel hypotheses on cell apoptosis upon treatment with gaseous plasma. Finally, recent advances in plasma nanoscience are illustrated with several examples and a roadmap for future activities is presented.

  14. Brazing vacuum ceramic tubes for magnets applications

    Energy Technology Data Exchange (ETDEWEB)

    Bagnato, O.R.; Francisco, R.F. [Laboratorio Nacional de Luz Sincrotron (LNLS), SP (Brazil); Gobbi, A.L. [Laboratorio Nacional de Nanotecbologia (LNNano), SP (Brazil); Falvo, T. [Engecer Ltda, Sao Carlos, SP (Brazil)

    2014-07-01

    Full text: The Sirius Project is an initiative of the Brazilian Synchrotron Light Laboratory - LNLS (CNPEM - MCTI ), for the design, construction and operation of a new synchrotron radiation source 3rd generation, with high brightness and energy of the electrons of 3. 0 GeV. Among many other components, will be built 80 ceramic cameras embedded in specials magnets, whose function is to act to correct the orbit of the electron beam in the storage ring. The ceramic chamber is crucial for this application because this material is transparent to the magnetic field generated in the electro magnet and thus acts directly on the electron beam. The difficulty of these constructive components lies in the fact that, the ceramic components must be attached to metal components will join vacuum chambers that make up the ring, and then must present excellent mechanical and vacuum tight. The process of chemical bonding between the ceramic and metal components is performed by brazing in high vacuum. After brazing, is deposited a film of copper with 7 micrometers thickness. The objective of this paper is to describe the process of film deposition and brazing of copper and the excellent results obtained in the production, mechanical characterization, microstructural and tightness. The results obtained with the process indicate an homogeneous film with high adhesion and electrical resistance near the estimated values??. Tests are being carried out by XPS and SEM techniques for chemical and structural characterization. (author)

  15. Axisymmetric charge-conservative electromagnetic particle simulation algorithm on unstructured grids: Application to microwave vacuum electronic devices

    Science.gov (United States)

    Na, Dong-Yeop; Omelchenko, Yuri A.; Moon, Haksu; Borges, Ben-Hur V.; Teixeira, Fernando L.

    2017-10-01

    We present a charge-conservative electromagnetic particle-in-cell (EM-PIC) algorithm optimized for the analysis of vacuum electronic devices (VEDs) with cylindrical symmetry (axisymmetry). We exploit the axisymmetry present in the device geometry, fields, and sources to reduce the dimensionality of the problem from 3D to 2D. Further, we employ 'transformation optics' principles to map the original problem in polar coordinates with metric tensor diag (1 ,ρ2 , 1) to an equivalent problem on a Cartesian metric tensor diag (1 , 1 , 1) with an effective (artificial) inhomogeneous medium introduced. The resulting problem in the meridian (ρz) plane is discretized using an unstructured 2D mesh considering TEϕ-polarized fields. Electromagnetic field and source (node-based charges and edge-based currents) variables are expressed as differential forms of various degrees, and discretized using Whitney forms. Using leapfrog time integration, we obtain a mixed E - B finite-element time-domain scheme for the full-discrete Maxwell's equations. We achieve a local and explicit time update for the field equations by employing the sparse approximate inverse (SPAI) algorithm. Interpolating field values to particles' positions for solving Newton-Lorentz equations of motion is also done via Whitney forms. Particles are advanced using the Boris algorithm with relativistic correction. A recently introduced charge-conserving scatter scheme tailored for 2D unstructured grids is used in the scatter step. The algorithm is validated considering cylindrical cavity and space-charge-limited cylindrical diode problems. We use the algorithm to investigate the physical performance of VEDs designed to harness particle bunching effects arising from the coherent (resonance) Cerenkov electron beam interactions within micro-machined slow wave structures.

  16. The Tynode: A new vacuum electron multiplier

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Harry van der, E-mail: vdgraaf@nikhef.nl [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); Akhtar, Hassan; Budko, Neil; Chan, Hong Wah; Hagen, Cornelis W. [Delft University of Technology, Delft (Netherlands); Hansson, Conny C.T. [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); Nützel, Gert; Pinto, Serge D. [Photonis, Roden (Netherlands); Prodanović, Violeta; Raftari, Behrouz; Sarro, Pasqualina M. [Delft University of Technology, Delft (Netherlands); Sinsheimer, John; Smedley, John [Brookhaven National Laboratory, Upton, NY 11973 (United States); Tao, Shuxia [Eindhoven University of Technology/DIFFER (Netherlands); Theulings, Anne M.M.G. [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); Vuik, Kees [Delft University of Technology, Delft (Netherlands)

    2017-03-01

    By placing, in vacuum, a stack of transmission dynodes (tynodes) on top of a CMOS pixel chip, a single free electron detector could be made with outstanding performance in terms of spatial and time resolution. The essential object is the tynode: an ultra thin membrane, which emits, at the impact of an energetic electron on one side, a multiple of electrons at the other side. The electron yields of tynodes have been calculated by means of GEANT-4 Monte Carlo simulations, applying special low-energy extensions. The results are in line with another simulation based on a continuous charge-diffusion model. By means of Micro Electro Mechanical System (MEMS) technology, tynodes and test samples have been realized. The secondary electron yield of several samples has been measured in three different setups. Finally, several possibilities to improve the yield are presented.

  17. Physical electronics handbook of vacuum physics

    CERN Document Server

    Beck, A H

    2013-01-01

    Handbook of Vacuum Physics, Volume 2, Physical Electronics, discusses the fundamentals of electric discharges in gases. Electrical discharges in gases is used generically to denote the passage of electricity through a gas and implicitly embraces the wide variety of physical phenomena which accompany such a discharge of electricity. The discharge currents may be as small as 10-16A in certain ionization growth studies, or be as large as megamperes in thermonuclear and plasma physics studies. Key topics discussed include collision phenomena in gases; surface phenomena and transport of charged par

  18. New Vacuum Electronic Devices for Radar

    Directory of Open Access Journals (Sweden)

    Hu Yinfu

    2016-08-01

    Full Text Available Vacuum Electronic Devices (VEDs which are considered as the heart of a radar system, play an important role in their development. VEDs and radar systems supplement and promote each other. Some new trends in VEDs have been observed with advancements in the simulation tools for designing VEDs, new materials, new fabrication techniques. Recently, the performance of VEDs has greatly improved. In addition, new devices have been invented, which have laid the foundation for the developments of radar detection technology. This study introduces the recent development trends and research results of VEDs from microwave and millimeter wave devices and power modules, integrated VEDs, terahertz VEDs, and high power VEDs.

  19. Results of vacuum assisted wound closure application.

    Science.gov (United States)

    Atay, Tolga; Burc, Halil; Baykal, Yakup Barbaros; Kirdemir, Vecihi

    2013-08-01

    In recent past, various methods have been used for wound treatment purpose. In this study, we aimed to compare our results established from the vacuum-assisted wound closure method, which has gained popularity day by day, with the literature. A total of 48 patients, who received vacuum-assisted wound closure treatment in our clinic between 2007and 2010, were included in this study. Etiological distribution of the patients was as follows: 32 traumatic, 6 pressure sore, 9 diabetic, and 1 iliac disarticulation. All cases were evaluated in terms of age, gender, etiology, period of treatment, and size of the wound. In the patients studied, 42 were men (87.5 %) and 6 were women (12.5 %). Mean age of the patients was 39.6 years (11-61 years). All of our traumatic patients suffered from open fracture. After the vacuum-assisted wound closure application, wound size reduced by 28.8 %, while the mean area of the surface of the wound was 94.7 cm(2) (13.7-216.3 cm(2)) on average. After the wounds became ready for surgery, 15 of them were treated with split-thickness grafting, 9 of them were treated with secondary suture, 18 of them were treated with full-thickness grafting, and 6 of them were treated with flap. Average period of the application of vacuum-assisted wound closure was 11.6 days (7-15 days). Results of vacuum-assisted wound closure can be regarded as satisfactory when cases are selected properly. This system has three different effect mechanisms. Firstly, it increases local blood flow on the wound bed. Secondly, cell proliferation is triggered following the mechanic stress. Thirdly, vacuum removes the proteases from the environment which obstructs healing. Therefore, it is intended to prepare alive wound bed which is required for subsequent soft tissue reconstructions.

  20. Applications of vacuum technology to novel accelerator problems

    Energy Technology Data Exchange (ETDEWEB)

    Garwin, E.L.

    1983-01-01

    Vacuum requirements for electron storage rings are most demanding to fulfill, due to the presence of gas desorption caused by large quantities of synchrotron radiation, the very limited area accessible for pumping ports, the need for 10/sup -9/ torr pressures in the ring, and for pressures a decade lower in the interaction regions. Design features of a wide variety of distributed ion sublimation pumps (DIP) developed at SLAC to meet these requirements are discussed, as well as NEG (non-evaporable getter) pumps tested for use in the Large Electron Positron Collider at CERN. Application of DIP to much higher pressures in electron damping rings for the Stanford Linear Collider are discussed.

  1. Historical evolution toward achieving ultrahigh vacuum in JEOL electron microscopes

    CERN Document Server

    Yoshimura, Nagamitsu

    2014-01-01

    This book describes the developmental history of the vacuum system of the transmission electron microscope (TEM) at the Japan Electron Optics Laboratory (JEOL) from its inception to its use in today’s high-technology microscopes. The author and his colleagues were engaged in developing vacuum technology for electron microscopes (JEM series) at JEOL for many years. This volume presents a summary and explanation of their work and the technology that makes possible a clean ultrahigh vacuum. The typical users of the TEM are top-level researchers working at the frontiers of new materials or with new biological specimens. They often use the TEM under extremely severe conditions, with problems sometimes occurring in the vacuum system of the microscopes. JEOL engineers then must work as quickly as possible to improve the vacuum evacuation system so as to prevent the recurrence of such problems. Among the wealth of explanatory material in this book are examples of users’ reports of problems in the vacuum system of...

  2. Measurement of the electron charge by a vacuum diode

    Science.gov (United States)

    Lacsný, Boris; Štubňa, Igor

    2016-03-01

    The measurement of the electron charge is a suitable experimental assignment for high-school and undergraduate courses of physics. We used two vacuum electron-tubes: (a) a double rectifying modern diode with an indirectly heated cathode and (b) a specially prepared double diode with a directly heated cathode and thermocouple. There was a small retarding potential between the cathode and anode, which gave an opportunity to assume Maxwell’s distribution of the velocities of the emitted electrons for the measurement of the electron charge. The electrical scheme for this measurement is simple and common electronic devices can be used. We obtained the value for the electron charge (1.491 ± 0.036) × 10-19 C if measured on the common commercial double diode vacuum-tube with the use of an optical pyrometer and (1.611 ± 0074) × 10-19 C if measured on the specially prepared double diode vacuum-tube using a thermocouple to determine the cathode temperature. The obtained values of the electron charge differs 0.11 × 10-19 C and 0.01 × 10-19 C from the currently accepted value e = 1.6021766208(98) × 10-19 C.

  3. ELECTRON AVALANCHE MODEL OF DIELECTRIC-VACUUM SURFACE BREAKDOWN

    Energy Technology Data Exchange (ETDEWEB)

    Lauer, E J

    2007-02-21

    The model assumes that an 'initiating event' results in positive ions on the surface near the anode and reverses the direction of the normal component of electric field so that electrons in vacuum are attracted to the dielectric locally. A sequence of surface electron avalanches progresses in steps from the anode to the cathode. For 200 kV across 1 cm, the spacing of avalanches is predicted to be about 13 microns. The time for avalanches to step from the anode to the cathode is predicted to be about a ns.

  4. Femtosecond electron-bunch dynamics in laser wakefields and vacuum

    Directory of Open Access Journals (Sweden)

    A. G. Khachatryan

    2007-12-01

    Full Text Available Recent advances in laser wakefield acceleration demonstrated the generation of extremely short (with a duration of a few femtoseconds relativistic electron bunches with relatively low (of the order of couple of percent energy spread. In this article we study the dynamics of such bunches in drift space (vacuum and in channel-guided laser wakefields. Analytical solutions were found for the transverse coordinate of an electron and for the bunch envelope in the wakefield in the case of arbitrary change in the energy. Our results show strong bunch dynamics already on a millimeter scale propagation distance both in plasma and in vacuum. When the bunch propagates in vacuum, its transverse sizes grow considerably; the same is observed for the normalized bunch emittance that worsens the focusability of the bunch. A scheme of two-stage laser wakefield accelerator with small drift space between the stages is proposed. It is found that fast longitudinal betatron phase mixing occurs in a femtosecond bunch when it propagates along the wakefield axis. When bunch propagates off axis, strong bunch decoherence and fast emittance degradation due to the finite bunch length was observed.

  5. Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers

    Science.gov (United States)

    2015-01-01

    colin.joye@nrl.navy.mil Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers Figure 2. Results from the 220 GHz TWT . (a) Small signal...Completed tube under hot test. 220 GHz TWT Demonstration The 220 GHz TWT device was based on spare parts from a commercially available CPI VKY2444T G...existing parts, our TWT bested this COTS EIK performance by a factor of 12x in power and 50x in bandwidth for the same size, weight and prime power

  6. Vacuum ultraviolet electronic properties of liquids. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Painter, L.R.

    1980-06-01

    A program to study the electronic structure of liquids over the energy range from 2 to 25 eV was carried out from November, 1968 to October 1980. These studies basically consisted of measuring the reflectance, transmittance, photoionization, and photoemission of liquids in the vacuum ultraviolet spectral region as a function of angle of incidence and photon energy. Such measurements are analyzed to yield the optical and dielectric functions of the liquid as functions of photon energy. A summary of the progress in the program is presented. (GHT)

  7. A double vacuum window mechanism for space-borne applications

    Science.gov (United States)

    Zilic, K.; Aboobaker, A.; Aubin, F.; Geach, C.; Hanany, S.; Jarosik, N.; Milligan, M.; Sagiv, I.

    2017-04-01

    We present a vacuum window mechanism that is useful for applications requiring two different vacuum windows in series, with one of them movable and resealable. Such applications include space borne instruments that can benefit from a thin vacuum window at low ambient pressures but must also have an optically open aperture at atmospheric pressures. We describe the implementation and successful operation with the E and B experiment balloon-borne payload, a millimeter-wave instrument designed to measure the polarization of the cosmic microwave background radiation.

  8. Application benefits of single-phase digitally controlled vacuum reclosers

    Energy Technology Data Exchange (ETDEWEB)

    Gadbury, J.E. [Cooper Industries, South Milwaukee, WI (United States). Cooper Power Systems

    1994-12-31

    The merging of digital control technology and vacuum interruption technology has given engineers a tool that allows them to successfully coordinate parts of their system where compromises would have been made in the past. This technology has recently been used in the area of single phase reclosers. The electronic method of recloser control is more flexible, more easily adjusted and tested, and more accurate than hydraulic control. The minimum trip level chosen does not alter the maximum continuous current capacity of the recloser as with traditional hydraulic control. The sequence coordination feature greatly enhances coordination. These benefits can all be provided without the need for additional distribution transformers, arresters, or other auxiliary power supplies. Installation costs of digitally controlled reclosers remain the same as the installation costs of hydraulic reclosers. Because of the innovations, single-phase digitally-controlled vacuum reclosers lend themselves to many specific applications. These would include long rural lines where several single phase reclosers are in series, single phase taps close to the substation where potential fault currents run high, remote areas where supervisory control and status indication would most likely be utilized, and in climates with low temperature extremes.

  9. Vacuum system operating experience review for fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Cadwallader, L.C.

    1994-03-01

    This report presents a review of vacuum system operating experiences from particle accelerator, fusion experiment, space simulation chamber, and other applications. Safety relevant operating experiences and accident information are discussed. Quantitative order-of-magnitude estimates of vacuum system component failure rates and accident initiating event frequencies are presented for use in risk assessment, reliability, and availability studies. Safety concerns with vacuum systems are discussed, including personnel safety, foreign material intrusion, and factors relevant to vacuum systems being the primary confinement boundary for tritium and activated dusts. This information should be useful to fusion system designers and safety analysts, such as the team working on the Engineering Design Activities for the International Thermonuclear Experimental Reactor.

  10. UNICOS CPC New Domains of Application: Vacuum and Cooling & Ventilation

    CERN Document Server

    Willeman, D; Bradu, B; Ortola, J

    2011-01-01

    The UNICOS (UNified Industrial COntrol System) framework, and concretely the CPC (Continuous Process Control) package, has been extensively used in the domain of continuous processes (e.g. cryogenics, gas flows) and also in others specific to the LHC machine as the collimators environmental measurements interlock system. The application of the UNICOS-CPC to other kind of processes: vacuum and the cooling and ventilation cases are depicted here. One of the major challenges was to figure out whether the model and devices created so far were also adapted for other type of processes (e.g. Vacuum). To illustrate this challenge two domain use cases will be shown: ISOLDE vacuum control system and the RFQ4 and STP18 (cooling & ventilation) control systems. Both scenarios will be illustrated emphasizing the adaptability of the UNICOS CPC package to create those applications and highlighting the discovered needed features to include in a future version of the UNICOS CPC package. This paper will a...

  11. A Brief Review on Metamaterial-Based Vacuum Electronics for Terahertz and Microwave Science and Technology

    Science.gov (United States)

    Matsui, Tatsunosuke

    2017-09-01

    Metamaterials, which enable us to realize novel physical effects that cannot be achieved using natural materials, have been extensively studied in recent years and significant progress has been made, especially in the field of optics. This game-changing concept has also initiated a rich variety of research activity in vacuum electronics. Here we review the recent development of metamaterial-based vacuum electronics for terahertz (THz) and microwave science and technology. The reversed Cherenkov radiation (RCR) in double-negative (DNG) metamaterials predicted by Veselago back in the 1960s has been experimentally verified in the microwave frequency range by utilizing specially designed DNG metamaterials. The interaction of an electron beam (e-beam) with DNG metamaterials may lead to the realization of novel applications such as microwave and THz radiation sources, accelerators, and even the visualization of invisibility cloaks. Smith-Purcell radiation (SPR) has recently received renewed interest owing to the development of metamaterials and the concept of spoof surface plasmon polaritons, as discussed in this review, and recent results on e-beam-induced directional and wide-band THz radiation with sharp multiple peaks from a graded grating, as well as directional and monochromatic special SPR and their possible application to THz orotron devices, are also reviewed.

  12. Terra Vac In Situ Vacuum Extraction System: Applications Analysis Report

    Science.gov (United States)

    This document is an evaluation of the Terra Vac in situ vacuum extraction system and its applicability as a treatment method for waste site cleanup. This report analyzes the results from the Superfund Innovative Technology Evaluation (SITE) Program’s 56-day demonstration at t...

  13. Vacuum deposited polymer/metal films for optical applications

    Science.gov (United States)

    Affinito, J. D.; Martin, P. M.; Gross, M. E.; Coronado, C.; Greenwell, E.

    1995-04-01

    Vacuum deposited Polymer/Silver/Polymer reflectors and Tantalum/Polymer/Aluminum Fabry-Perot interference filters were fabricated in a vacuun web coating operation on polyester substrates with a new, high speed deposition process. Reflectivities were measured in the wavelength range from 0.3 to 0.8(mu)m. This new vacuum processing technique has been shown to be capable of deposition line speeds in excess of 500 linear meters/minute. Central to this technique is a new position process for the high rate deposition of polymer films. This polymer process involves the flash evaporation of an acrylic monomer onto a moving substrate. The monomer is subsequently cured by an electron beam or ultraviolet light. This high speed polymer film deposition process has been named the PML process -- for Polymer Multi-Layer. Also, vacuum deposited, index matched, polymer/CaF(sub 2) composites were fabricated from monomer slurries that were subsequently cured with LTV light. This second technique is called the Liquid Multi-Layer (or LML) process. Each of these polymer processes is compatible with each other and with conventional vacuum deposition processes such as sputtering or evaporation.

  14. Development of precision numerical controlled high vacuum electron beam welding machine

    CERN Document Server

    Li Shao Lin

    2002-01-01

    The structure, main technical parameters and characteristics of the precision numerical controlled high vacuum electron beam welding machine are introduced. The design principle, some features and solutions to some key technique problems of this new type machine are described

  15. In-vacuum active electronics for microfabricated ion traps.

    Science.gov (United States)

    Guise, Nicholas D; Fallek, Spencer D; Hayden, Harley; Pai, C-S; Volin, Curtis; Brown, K R; Merrill, J True; Harter, Alexa W; Amini, Jason M; Lust, Lisa M; Muldoon, Kelly; Carlson, Doug; Budach, Jerry

    2014-06-01

    The advent of microfabricated ion traps for the quantum information community has allowed research groups to build traps that incorporate an unprecedented number of trapping zones. However, as device complexity has grown, the number of digital-to-analog converter (DAC) channels needed to control these devices has grown as well, with some of the largest trap assemblies now requiring nearly one hundred DAC channels. Providing electrical connections for these channels into a vacuum chamber can be bulky and difficult to scale beyond the current numbers of trap electrodes. This paper reports on the development and testing of an in-vacuum DAC system that uses only 9 vacuum feedthrough connections to control a 78-electrode microfabricated ion trap. The system is characterized by trapping single and multiple (40)Ca(+) ions. The measured axial mode stability, ion heating rates, and transport fidelities for a trapped ion are comparable to systems with external (air-side) commercial DACs.

  16. Systems and Methods for Fabricating Carbon Nanotube-Based Vacuum Electronic Devices

    Science.gov (United States)

    Manohara, Harish (Inventor); Toda, Risaku (Inventor); Del Castillo, Linda Y. (Inventor); Murthy, Rakesh (Inventor)

    2015-01-01

    Systems and methods in accordance with embodiments of the invention proficiently produce carbon nanotube-based vacuum electronic devices. In one embodiment a method of fabricating a carbon nanotube-based vacuum electronic device includes: growing carbon nanotubes onto a substrate to form a cathode; assembling a stack that includes the cathode, an anode, and a first layer that includes an alignment slot; disposing a microsphere partially into the alignment slot during the assembling of the stack such that the microsphere protrudes from the alignment slot and can thereby separate the first layer from an adjacent layer; and encasing the stack in a vacuum sealed container.

  17. Vacuum Arc Ion Sources: Recent Developments and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Ian; Oks, Efim

    2005-05-01

    The vacuum arc ion source has evolved over the past twenty years into a standard laboratory tool for the production of high current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. The primary application of this kind of source has evolved to be ion implantation for material surface modification. Another important use is for injection of high current beams of heavy metal ions into the front ends of particle accelerators, and much excellent work has been carried out in recent years in optimizing the source for reliable accelerator application. The source also provides a valuable tool for the investigation of the fundamental plasma physics of vacuum arc plasma discharges. As the use of the source has grown and diversified, at the same time the ion source performance and operational characteristics have been improved in a variety of different ways also. Here we review the growth and status of vacuum arc ion sources around the world, and summarize some of the applications for which the sources have been used.

  18. Recent advances and applications of gas chromatography vacuum ultraviolet spectroscopy.

    Science.gov (United States)

    Santos, Inês C; Schug, Kevin A

    2017-01-01

    The vacuum ultraviolet spectrophotometer was developed recently as an alternative to existing gas chromatography detectors. This detector measures the absorption of gas-phase chemical species in the range of 120-240 nm, where all chemical compounds present unique absorption spectra. Therefore, qualitative analysis can be performed and quantification follows standard Beer-Lambert law principles. Different fields of application, such as petrochemical, food, and environmental analysis have been explored. Commonly demonstrated is the capability for facile deconvolution of co-eluting analytes. The concept of additive absorption for co-eluting analytes has also been advanced for classification and speciation of complex mixtures using a data treatment procedure termed time interval deconvolution. Furthermore, pseudo-absolute quantitation can be performed for system diagnosis, as well as potentially calibrationless quantitation. In this manuscript an overview of these features, the vacuum ultraviolet spectrophotometer instrumentation, and performance capabilities are given. A discussion of the applications of the vacuum ultraviolet detector is provided by describing and discussing the papers published thus far since 2014. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Vacuum insulation panels for building applications: A review and beyond

    Energy Technology Data Exchange (ETDEWEB)

    Baetens, Ruben [Department of Building Materials and Structures, SINTEF Building and Infrastructure, NO-7465 Trondheim (Norway); Department of Civil and Transport Engineering, Norwegian University of Science and Technology (NTNU), NO-7491 Trondheim (Norway); Laboratory of Building Physics, Department of Civil Engineering, Catholic University of Leuven (KUL), BE-3001 Heverlee (Belgium); Jelle, Bjoern Petter [Department of Building Materials and Structures, SINTEF Building and Infrastructure, NO-7465 Trondheim (Norway); Department of Civil and Transport Engineering, Norwegian University of Science and Technology (NTNU), NO-7491 Trondheim (Norway); Thue, Jan Vincent [Department of Civil and Transport Engineering, Norwegian University of Science and Technology (NTNU), NO-7491 Trondheim (Norway); Tenpierik, Martin J. [Faculty of Architecture, Urbanism and Building Sciences, Delft University of Technology, Julianalaan 134, 2628 BL Delft (Netherlands); Grynning, Steinar; Uvsloekk, Sivert [Department of Building Materials and Structures, SINTEF Building and Infrastructure, NO-7465 Trondheim (Norway); Gustavsen, Arild [Department of Architectural Design, History and Technology, Norwegian University of Science and Technology (NTNU), NO-7491 Trondheim (Norway)

    2010-02-15

    Vacuum insulation panels (VIPs) are regarded as one of the most promising high performance thermal insulation solutions on the market today. Thermal performances three to six times better than still-air are achieved by applying a vacuum to an encapsulated micro-porous material, resulting in a great potential for combining the reduction of energy consumption in buildings with slim constructions. However, thermal bridging due to the panel envelope and degradation of thermal performance through time occurs with current technology. Furthermore, VIPs cannot be cut on site and the panels are fragile towards damaging. These effects have to be taken into account for building applications as they may diminish the overall usability and thermal performance. This paper is as far as the authors know the first comprehensive review on VIPs. Properties, requirements and possibilities of foil encapsulated VIPs for building applications are studied based on available literature, emphasizing thermal bridging and degradation through time. An extension is made towards gas-filled panels and aerogels, showing that other high performance thermal insulation solutions do exist. Combining the technology of these solutions and others may lead to a new leap forward. Feasible paths beyond VIPs are investigated and possibilities such as vacuum insulation materials (VIMs) and nano insulation materials (NIMs) are proposed. (author)

  20. Development of self-aligned gated porous silicon microtip field emission arrays for vacuum microelectronic applications

    Science.gov (United States)

    Jessing, Jeffrey Richard

    Solid state microelectronics is the dominate technology in the present day electronics industry. However, as the physical dimensions decrease, it is becoming apparent that solid state devices have inherent performance limitations, such as finite saturation drift velocity, high temperature degradation, and failure in extreme radiation environments. To address these problems a relatively new technology, called vacuum microelectronics, has emerged. Vacuum microelectronics encompasses the fabrication, characterization, and application of various devices whose operation is based on vacuum ballistic transport of field emitted electrons from microminiature electrodes. The field of vacuum microelectronics has advanced at a rapid rate over the past decade; however, there remain key issues to be addressed prior to any widespread commercialization of this technology. Field emission arrays (FEAs) must operate at low voltages and generate high current densities with uniform, long-lifetime operation. The use of porous silicon cathodes in vacuum microelectronic applications is a promising alternative to existing silicon and metal field emitters. Surface modification of bulk crystalline silicon by electrochemical anodization in a concentrated hydrofluoric acid (HF) solution has been shown to produce large submicroscopic field enhancement and large emission area. The primary focus of this research was the development of novel gated FEAs based on porous silicon microtip cathodes. Device design consisted of both experimental and theoretical efforts. Employing semiconductor process technology, the successful fabrication of an operational self-aligned gated porous silicon microtip FEA was demonstrated. Small arrays exhibited Fowler-Nordheim characteristics over several decades of anode current. A peak stable current of approximately 60 to 70 nA per tip was obtained at less than 125 V. A correlation of anodization conditions with emission properties has been found, and a simple emission

  1. Electronic circuits fundamentals & applications

    CERN Document Server

    Tooley, Mike

    2015-01-01

    Electronics explained in one volume, using both theoretical and practical applications.New chapter on Raspberry PiCompanion website contains free electronic tools to aid learning for students and a question bank for lecturersPractical investigations and questions within each chapter help reinforce learning Mike Tooley provides all the information required to get to grips with the fundamentals of electronics, detailing the underpinning knowledge necessary to appreciate the operation of a wide range of electronic circuits, including amplifiers, logic circuits, power supplies and oscillators. The

  2. Research on area source electron gun in vacuum system

    Science.gov (United States)

    Qiu, Yafeng; Chang, Benkang; Shi, Feng; Qian, Yunsheng; Fu, Rongguo

    High-energy area source electron gun is a key component in image intensifier screen testing instrument. On the basis of the analysis of relationship between thermal emission characteristics, the shape of filament and the density of thermal electron emission, high-energy area source electron gun is designed. The distribution of electric field and electronic tracks are theoretically analyzed and calculated to make it has features of dispersing, uniform, converging and submerging. By testing a standard screen, correct the structure of high-energy area source electron gun to meet the requirements of test indexes and obtain reasonable high-energy area source electron gun. Its successful development provides effective technical support to the luminous screen test for uniformity, brightness, luminescence efficiency and afterglow and to the examination of other components (such as MCP parameters)of Low-light Image Intensifier.

  3. Observation of Live Ticks (Haemaphysalis flava) by Scanning Electron Microscopy under High Vacuum Pressure

    Science.gov (United States)

    Ishigaki, Yasuhito; Nakamura, Yuka; Oikawa, Yosaburo; Yano, Yasuhiro; Kuwabata, Susumu; Nakagawa, Hideaki; Tomosugi, Naohisa; Takegami, Tsutomu

    2012-01-01

    Scanning electron microscopes (SEM), which image sample surfaces by scanning with an electron beam, are widely used for steric observations of resting samples in basic and applied biology. Various conventional methods exist for SEM sample preparation. However, conventional SEM is not a good tool to observe living organisms because of the associated exposure to high vacuum pressure and electron beam radiation. Here we attempted SEM observations of live ticks. During 1.5×10−3 Pa vacuum pressure and electron beam irradiation with accelerated voltages (2–5 kV), many ticks remained alive and moved their legs. After 30-min observation, we removed the ticks from the SEM stage; they could walk actively under atmospheric pressure. When we tested 20 ticks (8 female adults and 12 nymphs), they survived for two days after SEM observation. These results indicate the resistance of ticks against SEM observation. Our second survival test showed that the electron beam, not vacuum conditions, results in tick death. Moreover, we describe the reaction of their legs to electron beam exposure. These findings open the new possibility of SEM observation of living organisms and showed the resistance of living ticks to vacuum condition in SEM. These data also indicate, for the first time, the usefulness of tick as a model system for biology under extreme condition. PMID:22431980

  4. Active vacuum brazing of CNT films to metal substrates for superior electron field emission performance.

    Science.gov (United States)

    Longtin, Rémi; Ramon Sanchez-Valencia, Juan; Shorubalko, Ivan; Furrer, Roman; Hack, Erwin; Elsener, Hansrudolf; Gröning, Oliver; Greenwood, Paul; Rupesinghe, Nalin; Teo, Kenneth; Leinenbach, Christian; Gröning, Pierangelo

    2015-02-01

    The joining of macroscopic films of vertically aligned multiwalled carbon nanotubes (CNTs) to titanium substrates is demonstrated by active vacuum brazing at 820 °C with a Ag-Cu-Ti alloy and at 880 °C with a Cu-Sn-Ti-Zr alloy. The brazing methodology was elaborated in order to enable the production of highly electrically and thermally conductive CNT/metal substrate contacts. The interfacial electrical resistances of the joints were measured to be as low as 0.35 Ω. The improved interfacial transport properties in the brazed films lead to superior electron field-emission properties when compared to the as-grown films. An emission current of 150 μA was drawn from the brazed nanotubes at an applied electric field of 0.6 V μm-1. The improvement in electron field-emission is mainly attributed to the reduction of the contact resistance between the nanotubes and the substrate. The joints have high re-melting temperatures up to the solidus temperatures of the alloys; far greater than what is achievable with standard solders, thus expanding the application potential of CNT films to high-current and high-power applications where substantial frictional or resistive heating is expected.

  5. Optimizing chirped laser pulse parameters for electron acceleration in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Akhyani, Mina; Jahangiri, Fazel; Niknam, Ali Reza; Massudi, Reza, E-mail: r-massudi@sbu.ac.ir [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran 1983969411 (Iran, Islamic Republic of)

    2015-11-14

    Electron dynamics in the field of a chirped linearly polarized laser pulse is investigated. Variations of electron energy gain versus chirp parameter, time duration, and initial phase of laser pulse are studied. Based on maximizing laser pulse asymmetry, a numerical optimization procedure is presented, which leads to the elimination of rapid fluctuations of gain versus the chirp parameter. Instead, a smooth variation is observed that considerably reduces the accuracy required for experimentally adjusting the chirp parameter.

  6. Vacuum-thermal-evaporation: the route for roll-to-roll production of large-area organic electronic circuits

    Science.gov (United States)

    Taylor, D. M.

    2015-05-01

    Surprisingly little consideration is apparently being given to vacuum-evaporation as the route for the roll-to-roll (R2R) production of large-area organic electronic circuits. While considerable progress has been made by combining silicon lithographic approaches with solution processing, it is not obvious that these will be compatible with a low-cost, high-speed R2R process. Most efforts at achieving this ambition are directed at conventional solution printing approaches such as inkjet and gravure. This is surprising considering that vacuum-evaporation of organic semiconductors (OSCs) is already used commercially in the production of organic light emitting diode displays. Beginning from a discussion of the materials and geometrical parameters determining transistor performance and drawing on results from numerous publications, this review makes a case for vacuum-evaporation as an enabler of R2R organic circuit production. The potential of the vacuum route is benchmarked against solution approaches and found to be highly competitive. For example, evaporated small molecules tend to have higher mobility than printed OSCs. High resolution metal patterning on plastic films is already a low-cost commercial process for high-volume packaging applications. Similarly, solvent-free flash-evaporation and polymerization of thin films on plastic substrates is also a high-volume commercial process and has been shown capable of producing robust gate dielectrics. Reports of basic logic circuit elements produced in a vacuum R2R environment are reviewed and shown to be superior to all-solution printing approaches. Finally, the main issues that need to be resolved in order to fully develop the vacuum route to R2R circuit production are highlighted.

  7. Two types of proton-electron atoms in a vacuum and an extremely strong magnetic field

    CERN Document Server

    Fedaruk, R

    2010-01-01

    The Rutherford planetary model of a proton-electron atom is modified. Besides the Coulomb interaction of the point electron with the proton, its strong Coulomb interaction with the physical vacuum as well as the magnetic interaction between moving charges are taken into account. The vacuum interaction leads to the motion of the electron with the velocity of light \\textit{c} in the circle with the radius being equal to the so-called classical electron radius $r_e$. Therefore, the velocity of the electron consists of two components: the velocity $\\vec{\\upsilon }$ of the mechanical motion and the velocity $\\vec{c}$ of the photon-like motion. We postulate that $\\vec{\\upsilon }\\bot \\vec{c}$, and $\\upsilon > r_e $) and short ($ r > 10^8 T$) that are typical for neutron stars are discussed.

  8. Femtosecond electron-bunch dynamics in laser wakefields and vacuum

    NARCIS (Netherlands)

    Khachatryan, A.G.; Irman, A.; van Goor, F.A.; Boller, Klaus J.

    2007-01-01

    Recent advances in laser wakefield acceleration demonstrated the generation of extremely short (with a duration of a few femtoseconds) relativistic electron bunches with relatively low (of the order of couple of percent) energy spread. In this article we study the dynamics of such bunches in drift

  9. Field Emission Vacuum (FEV) Electronic Devices for Operation Above 500 Degrees Celsius

    Science.gov (United States)

    Peltz, L.; Jones, W. M.; Frampton, R. V.; Keith, A. R.; Scherer, A.

    2017-11-01

    Boeing is teamed with Caltech to develop FEV (Field-Emission Vacuum) electronics. Our Boeing-Caltech team has recently begun work, under NASA ROSES C.24 HOTTech program, to demonstrate robust FEV operating at 500C, towards Venus surface missions.

  10. Development of a surface conductivity measurement system for ultrahigh vacuum transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Minoda, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012 (Japan); Hatano, K.; Yazawa, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan)

    2009-11-15

    The surface conductivity measurement system using a micro-four-point probe (M4PP) had been developed for the ultrahigh vacuum transmission electron microscope (UHV-TEM). Since the current distribution in the sample crystals during the current voltage measurement by the M4PP is localized within the depth of several micrometers from the surface, the system is sensitive to the surface conductivity, which is related with the surface superstructure. It was installed in the main chamber of the TEM and the surface conductivity can be measured in situ. The surface structures were observed by reflection electron microscopy and diffraction (REM-RHEED). REM-RHEED enables us to observe the surface superstructures and their structure defects such as surface atomic steps and domain boundaries of the surface superstructure. Thus the effects of the defects on the surface conductivity can be investigated. In the present paper we present the surface conductivity measurement system and its application to the Si(111)-{radical}(3)x{radical}(3)-Ag surface prepared on the Si(111) vicinal surfaces. The result clearly showed that the surface conductivity was affected by step configuration.

  11. Application of vacuum technology: Vacuum insulated glazing- improving the energy efficiency of buildings

    OpenAIRE

    Memon, S.

    2014-01-01

    Heat loss through the windows of buildings is one of the factors contributing to high energy consumption for space heating resulting in excessive CO2 emissions which lead to climate change. Replacing standard double air filled glazing, U value of 2.85 Wm-2K-1, with vacuum insulated glazing, U value of approximately 0.8 Wm-2K-1, reduces the heat loss by more than three times and reduces the frame thickness due to the thinness of vacuum insulated glazing (8.15mm) as illustrated in Fig.1. Furthe...

  12. Proposed Physics Experiments for Laser-Driven Electron Linear Acceleration in a Dielectric Loaded Vacuum, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Byer, Robert L. [Stanford Univ., CA (United States). Dept. of Applied Physics. Edward L. Ginzton Lab.

    2016-07-08

    This final report summarizes the last three years of research on the development of advanced linear electron accelerators that utilize dielectric wave-guide vacuum channels pumped by high energy laser fields to accelerate beams of electrons.

  13. Metallic Na formation in NaCl crystals with irradiation of electron or vacuum ultraviolet photon

    Energy Technology Data Exchange (ETDEWEB)

    Owaki, Shigehiro [Osaka Prefecture Univ., Sakai, Osaka (Japan). Coll. of Integrated Arts and Sciences; Koyama, Shigeko; Takahashi, Masao; Kamada, Masao; Suzuki, Ryouichi

    1997-03-01

    Metallic Na was formed in NaCl single crystals with irradiation of a variety of radiation sources and analyzed the physical states with several methods. In the case of irradiation of 21 MeV electron pulses to the crystal blocks, the optical absorption and lifetime measurement of positron annihilation indicated appearance of Na clusters inside. Radiation effects of electron beam of 30 keV to the crystals in vacuum showed the appearance of not only metallic Na but atomic one during irradiation with Auger electron spectroscopy. Intense photon fluxes in vacuum ultraviolet region of synchrotron radiation were used as another source and an analyzing method of ultraviolet photoelectron spectroscopy. The results showed the metallic Na layered so thick that bulk plasmon can exist. (author)

  14. EDITORIAL: 17th International Summer School on Vacuum, Electron, and Ion Technologies (VEIT 2011)

    Science.gov (United States)

    van de Sanden, M. C. M.; Dimitrova, Miglena; Ghelev, Chavdar

    2012-03-01

    The International Summer School on Vacuum, Electron and Ion Technologies (VEIT) has been organized biennially since 1977, when the VEIT Summer School series was launched by the Institute of Electronics, Bulgarian Academy of Sciences. The aim was to act as a forum for the exchange and dissemination of knowledge and ideas on the latest developments in electron-, ion- and plasma-assisted technologies. The organizers of the 2011 edition of the event were the Institute of Electronics, Bulgarian Academy of Sciences, Sofia, Bulgaria and the Department of Applied Physics, Eindhoven University of Technology, Eindhoven, The Netherlands. Whilst the school initially provided a meeting place for researchers mainly from Eastern and Central European countries, its importance has grown issue by issue. The school is now a major scientific event and a meeting place for young scientists from Eastern and Western Europe involved in research and development associated with high-tech industries. Many former school participants have gone on to become leading scientists in research establishments and companies throughout the world. Leading international companies, such as High Voltage Engineering, Balzers, Varian, and Hauzer have used the VEIT forum to present their products through oral presentations, poster contributions and exhibits. The School Proceedings have been published in special issues of the international journals Vacuum, Plasma Processes and Polymers and Journal of Physics: Conference Series. The Seventeenth edition of VEIT was held in the Black Sea resort of Sunny Beach, Bulgaria on 19-23 September 2011. It was attended by 96 participants from 18 countries: Belgium, Brazil, Bulgaria, Czech Republic, Denmark, France, Germany, Greece, The Netherlands, Romania, Russia, Serbia, Sweden, Switzerland, Turkey, Ukraine, UK and USA. Following the tradition of publishing the VEIT Proceedings, a selection of papers presented at the event is published in this special issue of Journal of

  15. Preparation methodology and possible treatments for improved ceramics for high voltage vacuum applications

    CERN Document Server

    Tan, J

    1998-01-01

    The flashover characteristics of an insulator bridged high voltage vacuum gap can play an important role in the overall performance of a high voltage device, for example in the extreme environments of high energy particle accelerators. The detailed preparation of the insulators is, at present, governed by the commercial production methods and by standard bulk cleaning processes, which for a particular application may be far from optimum. The influence of the mechanical preparation, thermal history and particular cleaning technique have been investigated for commercially available alumina samples, with measurement of surface characteristics by scanning electron microscopy and laser diffraction, measurement of the secondary electron emission curve and analysis of the high voltage performance with the possibility of applied fields up to 200kV/cm. The results of the different measurements are discussed in the overall context of the problems encountered in the full sized high voltage devices, and suggestions are m...

  16. Electronic Noses and Applications

    Directory of Open Access Journals (Sweden)

    Martine LUMBRERAS

    2014-05-01

    Full Text Available Electronic noses are customized devices employed to detect and to identify gaseous mixtures, even to give the concentration of the atmosphere components. Nowadays, the research in this domain is more and more growing, in Europe and other countries in the world, for many applications, such as environmental protection, food industries, perfumery, public safety, medicine, and pharmacy. Electronic noses allow to detect many organic volatile compounds, for which there is no specific detector. They constitute an alternative to complex, long, and too expensive existing methods, unable to ensure continuous monitoring. Their conception deals with many related areas (metrology, chemistry, physics, electronics, informatics, statistics, modelisation as well as areas related to the molecules to be detected. The system training is a primary step: during a measurement under a gaseous atmosphere, we must record the sensor time-responses in a treatment system, while specifying the name of the concerned odor. This process must be repeated many times for each studied atmosphere, and for all the chosen atmospheres. So a learning data base can be created, made from representative parameters of all the realized measures. After this training stage, clustering software will classify the data analysis in “concentration” or “nature” groups. Using the group separation rules given by this supervised classification, the system will be able to find itself the name of an odor or a concentration.

  17. Vacuum Plasma Spray (VPS) Material Applications for Thruster Components

    Science.gov (United States)

    Elam, Sandra; Holmes, Richard; Hickman, Robert

    2006-01-01

    A variety of vacuum plasma spray (VPS) material systems have been successfully applied to injector and thrust chamber components. VPS offers a versatile fabrication process with relatively low costs to produce near net shape parts. The materials available with VPS increase operating margins and improve component life by providing superior thermal and oxidation protection in specific engine environments. Functional gradient materials (FGM) formed with VPS allow thrust chamber liners to be fabricated with GRCop-84 (an alloy of copper, chrome, and niobium) and a protective layer of NiCrAlY on the hot wall. A variety of thrust chamber liner designs have been fabricated to demonstrate the versatility of the process. Hot-fire test results have confined the improved durability and high temperature performance of the material systems for thrust chamber liners. Similar FGM s have been applied to provide superior thermal protection on injector faceplates with NiCrAlY and zirconia coatings. The durability of the applied materials has been demonstrated with hot-fire cycle testing on injector faceplates in high temperature environments. The material systems can benefit the components used in booster and main engine propulsion systems. More recent VPS efforts are focused on producing rhenium based material systems for high temperature applications to benefit in-space engines like reaction control system (RCS) thrusters.

  18. Non-Evaporable Getter Thin Film Coatings for Vacuum Applications

    CERN Document Server

    Prodromides, A E

    2002-01-01

    Getters are solid materials capable of chemisorbing gas molecules on their surface: getters are chemical pumps. They are widely used for a variety of applications such as in particle accelerators, vacuum tubes, field-emission display (FED), inert gas purification systems, H2 plasma purification, hydrogen species recycling as in the Tokamak Fusion Test Reactor. Among the different Non-Evaporable Getter (NEG) materials tested, the TiZrV alloys have the lowest activation temperature. For this reason, the TiZrV coatings were the object of this work. In particular, the aim of this investigation was to understand how to optimise three important properties of TiZrV coatings: to achieve the lowest possible activation temperature (Ta), and to obtain the highest pumping speed and surface pumping capacity. This objective is important in the context of the Large Hadron Collider (LHC) accelerator, since, before this work, the understanding and the knowledge of the TiZrV coatings properties were insufficient to adopt it fo...

  19. Two-dimensional simulation research of secondary electron emission avalanche discharge on vacuum insulator surface

    Science.gov (United States)

    Cai, Libing; Wang, Jianguo; Zhu, Xiangqin; Wang, Yue; Zhang, Dianhui

    2015-01-01

    Based on the secondary electron emission avalanche (SEEA) model, the SEEA discharge on the vacuum insulator surface is simulated by using a 2D PIC-MCC code developed by ourselves. The evolutions of the number of discharge electrons, insulator surface charge, current, and 2D particle distribution are obtained. The effects of the strength of the applied electric field, secondary electron yield coefficient, rise time of the pulse, length of the insulator on the discharge are investigated. The results show that the number of the SEEA electrons presents a quadratic dependence upon the applied field strength. The SEEA current, which is on the order of Ampere, is directly proportional to the field strength and secondary electron yield coefficient. Finally, the electron-stimulated outgassing is included in the simulation code, and a three-phase discharge curve is presented by the simulation, which agrees with the experimental data.

  20. Electron beam gun with kinematic coupling for high power RF vacuum devices

    Energy Technology Data Exchange (ETDEWEB)

    Borchard, Philipp

    2016-11-22

    An electron beam gun for a high power RF vacuum device has components joined by a fixed kinematic coupling to provide both precise alignment and high voltage electrical insulation of the components. The kinematic coupling has high strength ceramic elements directly bonded to one or more non-ductile rigid metal components using a high temperature active metal brazing alloy. The ceramic elements have a convex surface that mates with concave grooves in another one of the components. The kinematic coupling, for example, may join a cathode assembly and/or a beam shaping focus electrode to a gun stem, which is preferably composed of ceramic. The electron beam gun may be part of a high power RF vacuum device such as, for example, a gyrotron, klystron, or magnetron.

  1. PREFACE: 16th International Summer School on Vacuum, Electron, and Ion Technologies (VEIT 2009)

    Science.gov (United States)

    Möller, Wolfhard; Guerassimov, Nikolay; Ghelev, Chavdar

    2010-04-01

    The International Summer School on Vacuum, Electron and Ion Technologies (VEIT) has been organized biennially since 1977 when the series of VEIT Schools was launched by the Institute of Electronics, Bulgarian Academy of Sciences with the aim to act as a forum for interchange and dissemination of knowledge and ideas on the latest developments in electron-, ion-, and plasma-assisted technologies. Beginning from 2001, the school has been jointly organized with the Institute of Ion Beam Physics and Materials Research, Forschungszentrum Dresden-Rossendorf, Germany. Whereas, the school initially provided a meeting place for researchers mainly from Eastern and Central European countries, its importance grew issue by issue. The school is now a major scientific event and a meeting place for young scientists from Eastern and Western Europe involved in research and development associated with high-tech industries. Many former school participants have gone on to become leading scientists in research establishments and companies throughout the world. Leading international companies, such as High Voltage Engineering, Balzers, Varian, and Hauzer have used the VEIT forum to present their products through oral presentations, poster contributions or exhibits. The School Proceedings have been published in special issues of the international journals Vacuum, Plasma Processes and Polymers, Journal of Physics: Conference Series. The Sixteenth VEIT school was held in the Black Sea resort Sunny Beach, Bulgaria on 28 September to 2 October 2009. It was attended by close to 110 participants from 13 countries: Belgium, Bulgaria, Czech Republic, France, Germany, The Netherlands, Romania, Slovak Republic, Spain, Sweden, Ukraine, UK and USA. Following the tradition of publishing the VEIT Proceedings, a selection of papers presented at the event is published in this volume of Journal of Physics: Conference Series, under the originality and quality criteria of acceptance by the journal, including

  2. Gas Condensates onto a LHC Type Cryogenic Vacuum System Subjected to Electron Cloud

    CERN Multimedia

    Baglin, V

    2004-01-01

    In the Large Hadron Collider (LHC), the gas desorbed via photon stimulated molecular desorption or electron stimulated molecular desorption will be physisorbed onto the beam screen held between 5 and 20 K. Studies of the effects of the electron cloud onto a LHC type cryogenic vacuum chamber have been done with the cold bore experiment (COLDEX) installed in the CERN Super Proton Synchrotron (SPS). Experiments performed with gas condensates such as H2, H2O, CO and CO2 are described. Implications for the LHC design and operation are discussed.

  3. Ion effects in the SLC electron damping ring under exceptionally poor vacuum conditions

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, F.; Krejcik, P.; Minty, M.; Pritzkau, D.; Raubenheimer, T.; Ross, M.; Woodley, M.

    1997-10-01

    In 1996, due to a catastrophic kicker chamber failure in the SLC electron damping ring, the ring vacuum system was contaminated for several months. During this time, the vertical emittance of the beam extracted from the ring was increased by a large factor (4--20). The emittance slowly decreased as the vacuum pressure gradually improved. At the same time, an intermittent vertical instability was observed. Both the emittance blow-up and the instability behavior depended strongly on beam current, ring pressure, number of bunches in the ring (1 or 2), duty cycle, store time and betatron tunes. In this report, the authors describe the observations, and compare them with predictions from classical ion-trapping and ion-instability theories.

  4. Photoemission and Injection Properties of a Vacuum Photodiode with Two Negative-Electron-Affinity Semiconductor Electrodes

    Science.gov (United States)

    Rodionov, A. A.; Golyashov, V. A.; Chistokhin, I. B.; Jaroshevich, A. S.; Derebezov, I. A.; Haisler, V. A.; Shamirzaev, T. S.; Marakhovka, I. I.; Kopotilov, A. V.; Kislykh, N. V.; Mironov, A. V.; Aksenov, V. V.; Tereshchenko, O. E.

    2017-09-01

    The photoemission and injection properties of two GaAs/(Al,Ga)As electrodes with effective negative electron affinity (NEA) are studied in the parallel-plate capacitorlike vacuum photodiode. Both electrodes are bonded to the glass of the input windows, allowing measuring the quantum yield in the transmission and reflection modes. The photodiode with NEA states of both electrodes is sensitive to the illumination in the 400-900 nm range and produces the photocurrent with no bias applied between electrodes. The energy distribution of emitted electrons is studied as a function of the transverse energy component to the surface in the temperature range of 20-300 K. The presence of the fine structure in the photoemission spectra is associated with the electron-phonon coupling in two-dimensional quantized states in the band-bending region. The two-electrode vacuum photoemission system demonstrates the negative differential conductivity. The cathodoluminescence signal is measured as a function of free-electron injection energy with the threshold appearance less than 0.05 V between electrodes.

  5. The Radiation Reaction of a Point Electron as a Planck Vacuum Response Phenomenon

    Directory of Open Access Journals (Sweden)

    Daywitt W. C.

    2010-04-01

    Full Text Available The polarizability of the Planck vacuum (PV transforms the bare Coulomb field e = r 2 of a point charge into the observed field e = r 2 , where e and e are the bare and observed electronic charges respectively [1]. In uniform motion this observed field is transformed into the well-known relativistic electric and magnetic fields [2, p.380] by the interac- tion taking place between the bare-charge field and the PV continuum. Given the in- volvement of the PV in both these transformations, it is reasonable to conclude that the negative-energy PV must also be connected to the radiation reaction or damping force of an accelerated point electron. This short paper examines that conclusion by compar- ing it to an early indication [3] that the point electron problem may involve more than just a massive point charge.

  6. Use of high-thermal conductive aluminum nitride based ceramics in vacuum UHF electronic devices

    Directory of Open Access Journals (Sweden)

    Chasnyk V. I.

    2013-06-01

    Full Text Available Analysis of properties and characteristics of the alumina, beryllium oxide and aluminum nitride based ceramic materials used in UHF electronic devices has been made. It was shown that the complex of parameters including structural and functional characteristics of the high-thermal conductive aluminum nitride ceramics prevail over all types of alumina ceramics and is not lower than the same characteristics of the beryllium oxide ceramics especially at the temperatures higher than 450 °C. The examples of the prevailing use of the aluminum nitride ceramics inside vacuum UHF-region devices: TWT’s and klystrons.

  7. Vacuum deposition of organic molecules for photovoltaic applications

    OpenAIRE

    2012-01-01

    Organic photovoltaics have attracted considerable research and commercial interest due to their lightness, mechanical flexibility and low production costs. There are two main approaches for the fabrication of organic solar cells – solution and vacuum processing. The former relies on morphology control in polymer-fullerene blends resulting from natural phase separation in these systems. The latter takes advantage of solvent-free processing allowing highly complex multi-junction architectures s...

  8. Next generation non-vacuum, maskless, low temperature nanoparticle ink laser digital direct metal patterning for a large area flexible electronics.

    Directory of Open Access Journals (Sweden)

    Junyeob Yeo

    Full Text Available Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition- and photolithography-based conventional metal patterning processes. The "digital" nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm and high-performance flexible organic field effect transistor arrays.

  9. Next generation non-vacuum, maskless, low temperature nanoparticle ink laser digital direct metal patterning for a large area flexible electronics.

    Science.gov (United States)

    Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P; Ko, Seung Hwan

    2012-01-01

    Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition- and photolithography-based conventional metal patterning processes. The "digital" nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays.

  10. Next Generation Non-Vacuum, Maskless, Low Temperature Nanoparticle Ink Laser Digital Direct Metal Patterning for a Large Area Flexible Electronics

    Science.gov (United States)

    Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P.; Ko, Seung Hwan

    2012-01-01

    Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition– and photolithography-based conventional metal patterning processes. The “digital” nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays. PMID:22900011

  11. Vacuum ultraviolet circularly polarized coherent femtosecond pulses from laser seeded relativistic electrons

    Directory of Open Access Journals (Sweden)

    N. Čutić

    2011-03-01

    Full Text Available We have demonstrated the generation of circularly polarized coherent light pulses at 66 nm wavelength by combining laser seeding at 263 nm of a 375 MeV relativistic electron bunch with subsequent coherent harmonic generation from an elliptical undulator of APPLE-II type. Coherent pulses at higher harmonics in linear polarization have been produced and recorded up to the sixth order (44 nm. The duration of the generated pulses depends on the temporal overlap of the initial seed laser pulse and the electron bunch and was on the order of 200 fs. Currently, this setup is the only source worldwide producing coherent fs-light pulses with variable polarization in the vacuum ultraviolet.

  12. Solid Lubrication by Multiwalled Carbon Nanotubes in Air and in Vacuum for Space and Aeronautics Applications

    Science.gov (United States)

    Miyoshi, Kazuhisa; Street, Kenneth W., Jr.; Andraws, Rodney; Jacques, David; VanderWal, Randy L.; Sayir, Ali

    2005-01-01

    To evaluate recently developed aligned multiwalled carbon nanotubes (MWNTs) and dispersed MWNTs for solid lubrication applications, unidirectional sliding friction experiments were conducted with 440 C stainless steel balls and hemispherical alumina-yttria stabilized zirconia pins in sliding contact with the MWNTs deposited on quartz disks in air and in vacuum. The results indicate that MWNTs have superior solid lubrication friction properties and endurance lives in air and vacuum under dry conditions. The coefficient of friction of the dispersed MWNTs is close to 0.05 and 0.009 in air and in vacuum, respectively, showing good dry lubricating ability. The wear life of MWNTs exceeds 1 million passes in both air and vacuum showing good durability. In general, the low coefficient of friction can be attributed to the combination of the transferred, agglomerated patches of MWNTs on the counterpart ball or pin surfaces and the presence of tubular MWNTs at interfaces.

  13. PREFACE: Fifteenth International Summer School on Vacuum, Electron and Ion Technologies (VEIT 2007)

    Science.gov (United States)

    Guerassimov, Nikolay; Möller, Wolfhard; Ghelev, Chavdar

    2008-03-01

    The International Summer School on Vacuum, Electron and Ion Technologies (VEIT) has been organized biannually since 1977. It is a forum for the interchange and dissemination of knowledge and ideas on the latest developments in electron-, ion-, and plasma-assisted technologies. The organizers of the event (since 2001) have been the Institute of Electronics, Bulgarian Academy of Sciences, Sofia, Bulgaria, the Institute of Ion Beam Physics and Materials Research, Forschungszentrum Dresden-Rossendorf, Dresden, Germany, and the Evrika Foundation, Sofia, Bulgaria. The fifteenth meeting of VEIT was held in the Black Sea resort of Sozopol, Bulgaria from 17-21 September 2007 and was attended by around 120 participants from 17 countries: Australia, Belgium, Bulgaria, Canada, Czech Republic, Germany, Hungary, Italy, The Netherlands, Poland, Pakistan, Romania, Sweden, Switzerland, Ukraine, UK and USA. Following the tradition of publishing the VEIT Proceedings, a selection of papers presented at the event is published in this volume of Journal of Physics: Conference Series, all peer reviewed to meet the originality and quality criteria of the journal. The school consisted of 11 oral and 3 poster sessions. There were 17 invited talks of general interest and 12 progress reports were presented orally. In total 86 contributed papers were presented during the three poster sessions. There were several scientific highlights covering the fundamentals of gas discharges and interaction of fast particles with solids, a wide range of conventional and novel applications such as for hard coatings and optical/protective layers, nanosized structures produced by evaporation, sputtering or external irradiation. Recent achievements in the modification of materials using charged particles or laser beams, thin layers deposition, properties, and characterization and novel materials, techniques, devices were highlighted. Despite the busy scientific program, the atmosphere was relaxed and informal

  14. Biological applications of ultraviolet free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J.C.

    1997-10-01

    This review examines the possibilities for biological research using the three ultraviolet free-electron lasers that are nearing operational status in the US. The projected operating characteristics of major interest in biological research of the free-electron lasers at Brookhaven National Laboratory, the Thomas Jefferson National Accelerator Facility, and Duke University are presented. Experimental applications in the areas of far- and vacuum ultraviolet photophysics and photochemistry, structural biology, environmental photobiology, and medical research are discussed and the prospects for advances in these areas, based upon the characteristics of the new ultraviolet free-electron lasers, are evaluated.

  15. Polymers for electronic & photonic application

    CERN Document Server

    Wong, C P

    2013-01-01

    The most recent advances in the use of polymeric materials by the electronic industry can be found in Polymers for Electronic and Photonic Applications. This bookprovides in-depth coverage of photoresis for micro-lithography, microelectronic encapsulants and packaging, insulators, dielectrics for multichip packaging,electronic and photonic applications of polymeric materials, among many other topics. Intended for engineers and scientists who design, process, and manufacturemicroelectronic components, this book will also prove useful for hybrid and systems packaging managers who want to be info

  16. Matrix assisted ionization in vacuum, a sensitive and widely applicable ionization method for mass spectrometry.

    Science.gov (United States)

    Trimpin, Sarah; Inutan, Ellen D

    2013-05-01

    An astonishingly simple new method to produce gas-phase ions of small molecules as well as proteins from the solid state under cold vacuum conditions is described. This matrix assisted ionization vacuum (MAIV) mass spectrometry (MS) method produces multiply charged ions similar to those that typify electrospray ionization (ESI) and uses sample preparation methods that are nearly identical to matrix-assisted laser desorption/ionization (MALDI). Unlike these established methods, MAIV does not require a laser or voltage for ionization, and unlike the recently introduced matrix assisted ionization inlet method, does not require added heat. MAIV-MS requires only introduction of a crystalline mixture of the analyte incorporated with a suitable small molecule matrix compound such as 3-nitrobenzonitrile directly to the vacuum of the mass spectrometer. Vacuum intermediate pressure MALDI sources and modified ESI sources successfully produce ions for analysis by MS with this method. As in ESI-MS, ion formation is continuous and, without a laser, little chemical background is observed. MAIV, operating from a surface offers the possibility of significantly improved sensitivity relative to atmospheric pressure ionization because ions are produced in the vacuum region of the mass spectrometer eliminating losses associated with ion transfer from atmospheric pressure to vacuum. Mechanistic aspects and potential applications for this new ionization method are discussed.

  17. Separating and recycling metals from mixed metallic particles of crushed electronic wastes by vacuum metallurgy.

    Science.gov (United States)

    Zhan, Lu; Xu, Zhenming

    2009-09-15

    During the treatment of electronic wastes, a crushing process is usually used to strip metals from various base plates. Several methods have been applied to separate metals from nonmetals. However, mixed metallic particles obtained from these processes are still a mixture of various metals, including some toxic heavy metals such as lead and cadmium. With emphasis on recovering copper and other precious metals, there have hitherto been no satisfactory methods to recover these toxic metals. In this paper, the criterion of separating metals from mixed metallic particles by vacuum metallurgy is built. The results show that the metals with high vapor pressure have been almost recovered completely, leading to a considerable reduction of environmental pollution. In addition, the purity of copper in mixed particles has been improved from about 80 wt % to over 98 wt %.

  18. Industrial applications of electron accelerators

    CERN Document Server

    Cleland, M R

    2006-01-01

    This paper addresses the industrial applications of electron accelerators for modifying the physical, chemical or biological properties of materials and commercial products by treatment with ionizing radiation. Many beneficial effects can be obtained with these methods, which are known as radiation processing. The earliest practical applications occurred during the 1950s, and the business of radiation processing has been expanding since that time. The most prevalent applications are the modification of many different plastic and rubber products and the sterilization of single-use medical devices. Emerging applications are the pasteurization and preservation of foods and the treatment of toxic industrial wastes. Industrial accelerators can now provide electron energies greater than 10 MeV and average beam powers as high as 700 kW. The availability of high-energy, high-power electron beams is stimulating interest in the use of X-rays (bremsstrahlung) as an alternative to gamma rays from radioactive nuclides.

  19. Application of electron accelerator worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Machi, Sueo [Japan Atomic Industrial Forum, Inc., Tokyo (Japan)

    2003-02-01

    Electron accelerator is an important radiation source for radiation technology, which covers broad fields such as industry, health care, food and environmental protection. There are about 1,000 electron accelerators for radiation processing worldwide. Electron accelerator has advantage over Co-60 irradiator in term of high dose rate and power, assurance of safety, and higher economic performance at larger volume of irradiation. Accelerator generating higher energy in the range of 10 MeV and high power electron beam is now commercially available. There is a trend to use high-energy electron accelerator replacing Co-60 in case of large through-put of medical products. Irradiated foods, in particular species, are on the commercial market in 35 countries. Electron accelerator is used efficiently and economically for production of new or modified polymeric materials through radiation-induced cross-linking, grafting and polymerization reaction. Another important application of electron beam is the curing of surface coatings in the manufacture of products. Electron accelerators of large capacity are used for cleaning exhaust gases in industrial scale. Economic feasibility studies of this electron beam process have shown that this technology is more cost effective than the conventional process. It should be noted that the conventional limestone process produce gypsum as a by-product, which cannot be used in some countries. By contrast, the by-product of the electron beam process is a valuable fertilizer. (Y. Tanaka)

  20. Application of Vacuum Insulation Panels in the cold chain - Analysis of viability

    OpenAIRE

    Hammond, EC; Evans, JA

    2014-01-01

    © 2014 Elsevier Ltd and IIR.Vacuum Insulation Panels (VIPs) have already found application in some specialist applications where minimal energy consumption is important and space is at a premium. This paper investigates the feasibility of widespread application of VIPs in the cold chain by embedding them into the polyurethane (PU) foamed walls of traditional refrigerator and freezer cabinets. Thermal modelling of the insulation of a range of typical refrigerator and freezer cabinets as used t...

  1. Non-vacuum electron-beam carburizing and surface hardening of mild steel

    Energy Technology Data Exchange (ETDEWEB)

    Bataev, I.A., E-mail: ivanbataev@ngs.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Golkovskii, M.G., E-mail: M.G.Golkovski@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, Lavrentieva Prospect 11, 630090 Novosibirsk (Russian Federation); Losinskaya, A.A., E-mail: anna.losinskaya@mail.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Bataev, A.A., E-mail: bataev@adm.nstu.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Popelyukh, A.I., E-mail: aip13@mail.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Hassel, T., E-mail: hassel@iw.uni-hannover.de [Leibniz University, Welfengarten 1, 30167 Hannover (Germany); Golovin, D.D., E-mail: ddgolovin@yandex.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation)

    2014-12-15

    Highlights: • Steel specimens were carburized by non-vacuum electron-beam cladding. • The depth of the clad layers reached 2.6 mm. • The cladding rate was 1.8 m{sup 2}/h, the quenching rate 12.6 m{sup 2}/h. • The microhardness of the quenched and tempered layers reached 8 GPa. - Abstract: In this paper, we study the structure, microhardness, and tribological properties of surface layers of mild (0.19% C) steel, which was formed by electron-beam cladding with an iron–graphite powder mixture followed by quenching and tempering. A 1.4 MeV electron beam that was extracted into air was used. Cladding of steel with the iron–graphite mixture at a beam current of 24 and 26 mA formed a hypoeutectic cast iron layer (2.19% C) and a hypereutectoid steel (1.57% C) layer, which were 2.0 and 2.6 mm thick, respectively. The microhardness of the surface-quenched and tempered steel and cast iron layers was 7 and 8 GPa, respectively. Electron-beam quenching of the surface layers of hypoeutectic cast iron was accompanied with multiple cracking. During the quenching of the 1.57% C steel layer, crack formation was not observed. In friction tests against fixed and loose abrasive particles, the surface layers of hypereutectoid steel and hypoeutectic cast iron that were produced by electron-beam cladding and quenching had lower wear rates than mild steel after pack carburizing, quenching, and tempering. In the sliding wear tests, the cast iron clad layer, which was subjected to electron-beam quenching and tempering, exhibited the highest wear resistance. Electron-beam treatment can be used to harden local areas of large workpieces. It is reasonable to treat clad layers of high-carbon steel with electron-beam quenching and tempering. To prevent multiple cracking, white cast iron layers should not be quenched.

  2. 40 CFR 417.110 - Applicability; description of the SO3 solvent and vacuum sulfonation subcategory.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the SO3 solvent and vacuum sulfonation subcategory. 417.110 Section 417.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING...

  3. Vacuum ultraviolet spectroscopy of the lowest-lying electronic state in subcritical and supercritical water.

    Science.gov (United States)

    Marin, Timothy W; Janik, Ireneusz; Bartels, David M; Chipman, Daniel M

    2017-05-17

    The nature and extent of hydrogen bonding in water has been scrutinized for decades, including how it manifests in optical properties. Here we report vacuum ultraviolet absorption spectra for the lowest-lying electronic state of subcritical and supercritical water. For subcritical water, the spectrum redshifts considerably with increasing temperature, demonstrating the gradual breakdown of the hydrogen-bond network. Tuning the density at 381 °C gives insight into the extent of hydrogen bonding in supercritical water. The known gas-phase spectrum, including its vibronic structure, is duplicated in the low-density limit. With increasing density, the spectrum blueshifts and the vibronic structure is quenched as the water monomer becomes electronically perturbed. Fits to the supercritical water spectra demonstrate consistency with dimer/trimer fractions calculated from the water virial equation of state and equilibrium constants. Using the known water dimer interaction potential, we estimate the critical distance between molecules (ca. 4.5 Å) needed to explain the vibronic structure quenching.

  4. Overcoming Challenges in Kinetic Modeling of Magnetized Plasmas and Vacuum Electronic Devices

    Science.gov (United States)

    Omelchenko, Yuri; Na, Dong-Yeop; Teixeira, Fernando

    2017-10-01

    We transform the state-of-the art of plasma modeling by taking advantage of novel computational techniques for fast and robust integration of multiscale hybrid (full particle ions, fluid electrons, no displacement current) and full-PIC models. These models are implemented in 3D HYPERS and axisymmetric full-PIC CONPIC codes. HYPERS is a massively parallel, asynchronous code. The HYPERS solver does not step fields and particles synchronously in time but instead executes local variable updates (events) at their self-adaptive rates while preserving fundamental conservation laws. The charge-conserving CONPIC code has a matrix-free explicit finite-element (FE) solver based on a sparse-approximate inverse (SPAI) algorithm. This explicit solver approximates the inverse FE system matrix (``mass'' matrix) using successive sparsity pattern orders of the original matrix. It does not reduce the set of Maxwell's equations to a vector-wave (curl-curl) equation of second order but instead utilizes the standard coupled first-order Maxwell's system. We discuss the ability of our codes to accurately and efficiently account for multiscale physical phenomena in 3D magnetized space and laboratory plasmas and axisymmetric vacuum electronic devices.

  5. Vacuum Technology

    Energy Technology Data Exchange (ETDEWEB)

    Biltoft, P J

    2004-10-15

    The environmental condition called vacuum is created any time the pressure of a gas is reduced compared to atmospheric pressure. On earth we typically create a vacuum by connecting a pump capable of moving gas to a relatively leak free vessel. Through operation of the gas pump the number of gas molecules per unit volume is decreased within the vessel. As soon as one creates a vacuum natural forces (in this case entropy) work to restore equilibrium pressure; the practical effect of this is that gas molecules attempt to enter the evacuated space by any means possible. It is useful to think of vacuum in terms of a gas at a pressure below atmospheric pressure. In even the best vacuum vessels ever created there are approximately 3,500,000 molecules of gas per cubic meter of volume remaining inside the vessel. The lowest pressure environment known is in interstellar space where there are approximately four molecules of gas per cubic meter. Researchers are currently developing vacuum technology components (pumps, gauges, valves, etc.) using micro electro mechanical systems (MEMS) technology. Miniature vacuum components and systems will open the possibility for significant savings in energy cost and will open the doors to advances in electronics, manufacturing and semiconductor fabrication. In conclusion, an understanding of the basic principles of vacuum technology as presented in this summary is essential for the successful execution of all projects that involve vacuum technology. Using the principles described above, a practitioner of vacuum technology can design a vacuum system that will achieve the project requirements.

  6. Computer Applications: Using Electronic Spreadsheets.

    Science.gov (United States)

    Riley, Connee; And Others

    This instructional unit is intended to assist teachers in helping students learn to use electronic spreadsheets. The 11 learning activities included, all of which are designed for use in conjunction with Multiplan Spreadsheet Software, are arranged in order of increasing difficulty. An effort has been made to include problems applicable to each of…

  7. Vacuum mechatronics

    Science.gov (United States)

    Hackwood, Susan; Belinski, Steven E.; Beni, Gerardo

    1989-01-01

    The discipline of vacuum mechatronics is defined as the design and development of vacuum-compatible computer-controlled mechanisms for manipulating, sensing and testing in a vacuum environment. The importance of vacuum mechatronics is growing with an increased application of vacuum in space studies and in manufacturing for material processing, medicine, microelectronics, emission studies, lyophylisation, freeze drying and packaging. The quickly developing field of vacuum mechatronics will also be the driving force for the realization of an advanced era of totally enclosed clean manufacturing cells. High technology manufacturing has increasingly demanding requirements for precision manipulation, in situ process monitoring and contamination-free environments. To remove the contamination problems associated with human workers, the tendency in many manufacturing processes is to move towards total automation. This will become a requirement in the near future for e.g., microelectronics manufacturing. Automation in ultra-clean manufacturing environments is evolving into the concept of self-contained and fully enclosed manufacturing. A Self Contained Automated Robotic Factory (SCARF) is being developed as a flexible research facility for totally enclosed manufacturing. The construction and successful operation of a SCARF will provide a novel, flexible, self-contained, clean, vacuum manufacturing environment. SCARF also requires very high reliability and intelligent control. The trends in vacuum mechatronics and some of the key research issues are reviewed.

  8. Comparative analysis of Trichuris muris surface using conventional, low vacuum, environmental and field emission scanning electron microscopy.

    Science.gov (United States)

    Lopes Torres, Eduardo José; de Souza, Wanderley; Miranda, Kildare

    2013-09-23

    The whipworm of the genus Trichuris Roederer, 1791, is a nematode of worldwide distribution and comprises species that parasitize humans and other mammals. Infections caused by Trichuris spp. in mammals can lead to various intestinal diseases of human and veterinary interest. The morphology of Trichuris spp. and other helminths has been mostly studied using conventional scanning electron microscopy of chemically fixed, dried and metal-coated specimens, although this kind of preparation has been shown to introduce a variety of artifacts such as sample shrinking, loss of secreted products and/or hiding of small structures due to sample coating. Low vacuum (LVSEM) and environmental scanning electron microscopy (ESEM) have been applied to a variety of insulator samples, also used in the visualization of hydrated and/or live specimens in their native state. In the present work, we used LVSEM and ESEM to analyze the surface of T. muris and analyze its interaction with the host tissue using freshly fixed or unfixed hydrated samples. Analysis of hydrated samples showed a set of new features on the surface of the parasite and the host tissue, including the presence of the secretory products of the bacillary glands on the surface of the parasite, and the presence of mucous material and eggs on the intestinal surface. Field emission scanning electron microscopy (FESEM) was also applied to reveal the detailed structure of the glandular chambers in fixed, dried and metal coated samples. Taken together, the results show that analysis of hydrated samples may provide new insights in the structural organization of the surface of helminth parasites and its interaction with the infected tissue, suggesting that the application of alternative SEM techniques may open new perspectives for analysis in taxonomy, morphology and host-parasite interaction fields. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Analysis of Bubble Flow in the Deep-Penetration Molten Pool of Vacuum Electron Beam Welding

    Science.gov (United States)

    Luo, Yi; Wan, Rui; Zhu, Yang; Xie, Xiaojian

    2015-03-01

    Based on the vacuum electron beam welding with deep-penetration process, the convection phenomenon of the bubble flow in partially penetrated and fully penetrated molten pool of AZ91D magnesium alloy was simulated under the unsteady-state conditions. At the same time, the distributions of the cavity-type defects in deep-penetration weld were studied. The results showed that the cavity-type defects are more prone to distribute at the bottom of the weld and accumulate along the axis of the weld for the partially penetrated weld seam; there is a high incidence of cavity-type defects in the middle of the weld for the fully penetrated weld seam. As a smooth escape channel for the gas phase is formed in the fully penetrated molten pool, the possibility of gas escaping is much higher than that in the partially penetrated molten pool. A high liquid convection velocity is more conducive to the escape of the gas in molten pool. The liquid convection velocity in the fully penetrated molten pool is higher than that in the partially penetrated molten pool. So, the final gas fraction in the fully penetrated molten pool is low. Therefore, the appearance of cavity-type defects in the fully penetrated weld seam is less than that in the partially penetrated weld seam.

  10. Control of the Polarization of a Vacuum-Ultraviolet, High-Gain, Free-Electron Laser

    Directory of Open Access Journals (Sweden)

    Enrico Allaria

    2014-12-01

    Full Text Available The two single-pass, externally seeded free-electron lasers (FELs of the FERMI user facility are designed around Apple-II-type undulators that can operate at arbitrary polarization in the vacuum ultraviolet-to-soft x-ray spectral range. Furthermore, within each FEL tuning range, any output wavelength and polarization can be set in less than a minute of routine operations. We report the first demonstration of the full output polarization capabilities of FERMI FEL-1 in a campaign of experiments where the wavelength and nominal polarization are set to a series of representative values, and the polarization of the emitted intense pulses is thoroughly characterized by three independent instruments and methods, expressly developed for the task. The measured radiation polarization is consistently >90% and is not significantly spoiled by the transport optics; differing, relative transport losses for horizontal and vertical polarization become more prominent at longer wavelengths and lead to a non-negligible ellipticity for an originally circularly polarized state. The results from the different polarimeter setups validate each other, allow a cross-calibration of the instruments, and constitute a benchmark for user experiments.

  11. Measuring of plasma properties induced by non-vacuum electron beam welding

    Science.gov (United States)

    Reisgen, U.; Schleser, M.; Abdurakhmanov, A.; Gumenyuk, A.

    2012-01-01

    Electron beam plasma measurement was realised by means of DIABEAM system invented by ISF RWTH Aachen. The Langmuir probe method is used for measurement. The relative simplicity of the method and the possibility of dispersion of high power on the probe allow its application for the investigation of high-power electron beams. The key element of the method is a rotating thin tungsten wire, which intersects the beam transversely on its axis and collects part of the current by itself. The signals, which are registered in the DIABEAM as a voltage, were taken in the form of amplitude. The conversion of the probe current into the distribution along the beam radius was realised using the Abel's method. A voltage-current characteristic was built for the beam current. The local electron density as well as the electron temperature, the floating potential and the plasma potential were measured and calculated by means of this characteristic.

  12. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    Directory of Open Access Journals (Sweden)

    Xin-Bing Cheng

    2011-04-01

    Full Text Available The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the flatness of the output voltage is discussed before and after adding an insulation plate when a water load is used. It is found that the electron emission at the edges of the cathode holder is the main reason to cause the change of the flatness. Last, a piece of polyester film is used as a target to further show the electron emission of the cathode holder. This analysis shows that decreasing the electron emission of the cathode holder in such a pulse power modulator could be a good way to improve the quality of the output voltage.

  13. A vacuum tube vee-trough collector for solar heating and air conditioning applications

    Science.gov (United States)

    Selcuk, M. K.

    1978-01-01

    An analysis is conducted of the performance of a vee-trough vacuum tube collector proposed for use in solar heating and cooling applications. The vee-trough reflector is a triangular sectioned, flat surfaced reflector, whose axis is laid in the East-West direction. A vacuum tube receiver placed at the bottom of the vee-trough collects solar heat most efficiently since convection is completely eliminated. Radiation losses are reduced by use of selective coatings on the absorber. Owing to its high temperature capabilities (300-400 F), the proposed scheme could also be used for power generation applications in combination with an organic Rankine conversion system. It is especially recommended for unattended pumping stations since the reflectors only require reversal once every six months.

  14. Structural, optical and electrical characterization of vacuum-evaporated nanocrystalline CdSe thin films for photosensor applications

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Vipin; Sharma, D.K.; Sharma, Kapil [Krishna Institute of Engineering and Technology, Department of Physics, Ghaziabad (India); Dwivedi, D.K. [M.M.M University of Technology, Department of Physics, Gorakhpur (India)

    2016-11-15

    II-VI nanocrystalline semiconductors offer a wide range of applications in electronics, optoelectronics and photonics. Thin films of CdSe were deposited onto ultra-clean glass substrates by vacuum evaporation method. The as-deposited films were annealed in vacuum at 350 K. The structural, elemental, morphological, optical and electrical investigations of annealed films were carried out. The X-ray diffraction pattern of the films shows that films were polycrystalline in nature having hexagonal structure with preferential orientation of grains along (002) plane. SEM image indicates that the films were uniform and well covered to the glass substrate. EDAX analysis confirms the stoichiometric composition of the film. Raman spectra were used to observe the characteristic vibrational modes of CdSe. The energy band gap of these films was obtained by absorption spectra. The films were found to have a direct type of transition of band gap occurring at 1.75 eV. The dark electrical conductivity and photoconductivity reveals that the films were semiconducting in nature indicating the suitability of these films for photosensor applications. The Hall effect measurement reveals that the films have n-type electrical conductivity. (orig.)

  15. Structural, optical and electrical characterization of vacuum-evaporated nanocrystalline CdSe thin films for photosensor applications

    Science.gov (United States)

    Kumar, Vipin; Sharma, D. K.; Sharma, Kapil; Dwivedi, D. K.

    2016-11-01

    II-VI nanocrystalline semiconductors offer a wide range of applications in electronics, optoelectronics and photonics. Thin films of CdSe were deposited onto ultra-clean glass substrates by vacuum evaporation method. The as-deposited films were annealed in vacuum at 350 K. The structural, elemental, morphological, optical and electrical investigations of annealed films were carried out. The X-ray diffraction pattern of the films shows that films were polycrystalline in nature having hexagonal structure with preferential orientation of grains along (002) plane. SEM image indicates that the films were uniform and well covered to the glass substrate. EDAX analysis confirms the stoichiometric composition of the film. Raman spectra were used to observe the characteristic vibrational modes of CdSe. The energy band gap of these films was obtained by absorption spectra. The films were found to have a direct type of transition of band gap occurring at 1.75 eV. The dark electrical conductivity and photoconductivity reveals that the films were semiconducting in nature indicating the suitability of these films for photosensor applications. The Hall effect measurement reveals that the films have n-type electrical conductivity.

  16. PREFACE: International Symposium on Vacuum Science & Technology and its Application for Accelerators (IVS 2012)

    Science.gov (United States)

    Pandit, V. S.; Pal, Gautam

    2012-11-01

    The Indian Vacuum Society (IVS) was established in 1970 to promote vacuum science and technology in academic, industrial and R&D institutions in India. IVS is a member society of the International Union for Vacuum Science, Technique and Applications (IUVSTA). It has organized International and national symposia, short term courses and workshops on different aspects of Vacuum Science and Technology at regular intervals. So far 27 National symposia, 4 International Symposia and 47 courses have been organized at various locations in India. There has been an active participation from R&D establishments, universities and Indian industries during all these events. In view of the current global situation and emerging trends in vacuum technology, the executive committee of the IVS suggested to us that we organize an International Symposium at the Variable Energy Cyclotron Centre, Kolkata from 15-17 February 2012. At the Variable Energy Cyclotron Centre we have a large number of high vacuum systems used in the K130 Cyclotron and K500 Superconducting Cyclotron. Also a large cryogenic system using LHe plant is in operation for cryopanels and a superconducting magnet for K-500 Cyclotron. The main areas covered at the symposium were the production and measurement of vacuums, leak detection, design and development of large vacuum systems, vacuum metallurgy, vacuum materials and the application of high vacuums in cyclotrons, LINACS and other accelerators. This symposium provided an opportunity for interaction between active researchers and technologists and allowed them to review the current situation, report recent experimental results, share the available expertise and consider the future R&D efforts needed in this area. Keeping the industrial significance of vacuum technology in mind, an exhibition of the vacuum related equipment, accessories, products etc by various suppliers and manufactures was organized alongside the symposium. Participation by a large number of exhibitors

  17. Surface Effects and Challenges for Application of Piezoelectric Langasite Substrates in Surface Acoustic Wave Devices Caused by High Temperature Annealing under High Vacuum

    Directory of Open Access Journals (Sweden)

    Marietta Seifert

    2015-12-01

    Full Text Available Substrate materials that are high-temperature stable are essential for sensor devices which are applied at high temperatures. Although langasite is suggested as such a material, severe O and Ga diffusion into an O-affine deposited film was observed during annealing at high temperatures under vacuum conditions, leading to a damage of the metallization as well as a change of the properties of the substrate and finally to a failure of the device. Therefore, annealing of bare LGS (La 3 Ga 5 SiO 14 substrates at 800 ∘ C under high vacuum conditions is performed to analyze whether this pretreatment improves the suitability and stability of this material for high temperature applications in vacuum. To reveal the influence of the pretreatment on the subsequently deposited metallization, RuAl thin films are used as they are known to oxidize on LGS at high temperatures. A local study of the pretreated and metallized substrates using transmission electron microscopy reveals strong modification of the substrate surface. Micro cracks are visible. The composition of the substrate is strongly altered at those regions. Severe challenges for the application of LGS substrates under high-temperature vacuum conditions arise from these substrate damages, revealing that the pretreatment does not improve the applicability.

  18. Mechanics and Physics of Precise Vacuum Mechanisms

    CERN Document Server

    Deulin, E. A; Panfilov, Yu V; Nevshupa, R. A

    2010-01-01

    In this book the Russian expertise in the field of the design of precise vacuum mechanics is summarized. A wide range of physical applications of mechanism design in electronic, optical-electronic, chemical, and aerospace industries is presented in a comprehensible way. Topics treated include the method of microparticles flow regulation and its determination in vacuum equipment and mechanisms of electronics; precise mechanisms of nanoscale precision based on magnetic and electric rheology; precise harmonic rotary and not-coaxial nut-screw linear motion vacuum feedthroughs with technical parameters considered the best in the world; elastically deformed vacuum motion feedthroughs without friction couples usage; the computer system of vacuum mechanisms failure predicting. This English edition incorporates a number of features which should improve its usefulness as a textbook without changing the basic organization or the general philosophy of presentation of the subject matter of the original Russian work. Exper...

  19. [POSSIBILITIES OF VACUUM THERAPY APPLICATION IN DISORDERS OF VENOUS OUTFLOW IN ISLET GRAFTS].

    Science.gov (United States)

    Badyul, P O; Samoylenko, G E; Nor, N M; Slesarenko, K S

    2015-07-01

    The experience of "distressed" (problematic) flaps application in 33 patients with soft tissue defects over 2010-2014 years were analysed. It was proposed to use the local negative pressure for the prevention and treatment of complications associated with venous insufficiency or trombosis in using of plastics with vascularised complexes of tissues. Vacuum-therapy was conducted with the help of negative pressure apparatus "AGATE-Dnepr" (Ukraine) by attaching silver-containing polyurethane sponge on the operating zone, covering the flap with the surrounding skin netting band "Grassolind". The recommended standard of negative pressure of 75-125 mm Hg, both in impulse and in continuous mode was used. The high efficiency of vacuum-therapy for survival of grafts has been demonstrated. Thus, it might be considered as an effective element of prevention and treatment of complications associated with venous insufficiency or trombosis using of vascularised tissue complex plastics of defects.

  20. Field Emission in Vacuum Microelectronics

    CERN Document Server

    Fursey, George; Schwoebel, Paul

    2005-01-01

    Field emission is a phenomenon described by quantum mechanics. Its emission capability is millions times higher than that of any other known types of electron emission. Nowadays this phenomenon is experiencing a new life due to wonderful applications in the atomic resolution microscopy, in electronic holography, and in the vacuum micro- and nanoelectronics in general. The main field emission properties, and some most remarkable experimental facts and applications, are described in this book.

  1. SPEAKING IN LIGHT - Jupiter radio signals as deflections of light-emitting electron beams in a vacuum chamber

    Science.gov (United States)

    Petrovic, K.

    2015-10-01

    Light emitting electron beam generated in a vacuum chamber is used as a medium for visualizing Jupiter's electromagnetic radiation. Dual dipole array antenna is receiving HF radio signals that are next amplified to radiate a strong electromagnetic field capable of influencing the propagation of electron beam in plasma. Installation aims to provide a platform for observing the characteristics of light emitting beam in 3D, as opposed to the experiments with cathode ray tubes in 2-dimensional television screens. Gas giant 'speaking' to us by radio waves bends the light in the tube, allowing us to see and hear the messages of Jupiter - God of light and sky.

  2. Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.

    Science.gov (United States)

    Jiang, Xinian

    2010-04-26

    Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80?C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.

  3. Advanced electrical and electronics materials processes and applications

    CERN Document Server

    Gupta, K M

    2015-01-01

    This comprehensive and unique book is intended to cover the vast and fast-growing field of electrical and electronic materials and their engineering in accordance with modern developments.   Basic and pre-requisite information has been included for easy transition to more complex topics. Latest developments in various fields of materials and their sciences/engineering, processing and applications have been included. Latest topics like PLZT, vacuum as insulator, fiber-optics, high temperature superconductors, smart materials, ferromagnetic semiconductors etc. are covered. Illustrations and exa

  4. APPLICATION OF VACUUM SALT DISTILLATION TECHNOLOGY FOR THE REMOVAL OF FLUORIDE

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, R.; Pak, D.

    2011-08-10

    Vacuum distillation of chloride salts from plutonium oxide (PuO{sub 2}) and simulant PuO{sub 2} has been previously demonstrated at Department of Energy (DOE) sites using kilogram quantities of chloride salt. The apparatus for vacuum distillation contains a zone heated using a furnace and a zone actively cooled using either recirculated water or compressed air. During a vacuum distillation operation, a sample boat containing the feed material is placed into the apparatus while it is cool, and the system is sealed. The system is evacuated using a vacuum pump. Once a sufficient vacuum is attained, heating begins. Volatile salts distill from the heated zone to the cooled zone where they condense, leaving behind the non-volatile materials in the feed boat. The application of vacuum salt distillation (VSD) is of interest to the HB-Line Facility and the MOX Fuel Fabrication Facility (MFFF) at the Savannah River Site (SRS). Both facilities are involved in efforts to disposition excess fissile materials. Many of these materials contain chloride and fluoride salt concentrations which make them unsuitable for dissolution without prior removal of the chloride and fluoride salts. Between September 2009 and January 2011, the Savannah River National Laboratory (SRNL) and HB-Line designed, developed, tested, and successfully deployed a system for the distillation of chloride salts. Subsequent efforts are attempting to adapt the technology for the removal of fluoride. Fluoride salts of interest are less-volatile than the corresponding chloride salts. Consequently, an alternate approach is required for the removal of fluoride without significantly increasing the operating temperature. HB-Line Engineering requested SRNL to evaluate and demonstrate the feasibility of an alternate approach using both non-radioactive simulants and plutonium-bearing materials. Whereas the earlier developments targeted the removal of sodium chloride (NaCl) and potassium chloride (KCl), the current

  5. Optimal application of the Contura multilumen balloon breast brachytherapy catheter vacuum port to deliver accelerated partial breast irradiation.

    Science.gov (United States)

    Tokita, Kenneth M; Cuttino, Laurie W; Vicini, Frank A; Arthur, Douglas W; Todor, Dorin A; Julian, Thomas B; Lyden, Maureen R

    2011-01-01

    The impact of using the Contura multilumen balloon (MLB) (SenoRx, Inc., Irvine, CA) breast brachytherapy catheter's vacuum port in patients treated with accelerated partial breast irradiation (APBI) was analyzed. Data from 32 patients at two sites were reviewed. Variables analyzed included the seroma fluid (SF):air volume around the MLB before and after vacuum port use and on its ability to improve (1) the eligibility of patients for APBI and (2) dose coverage of the planning target volume for evaluation (PTV_EVAL) in eligible patients. The median SF/air volume before vacuum removal was 6.8 cc vs. 0.8 cc after vacuum removal (median reduction in SF/air volume was 90.5%). Before vacuum port use, the median SF/air volume expressed as percentage of the PTV_EVAL was 7.8% (range, 1.9-26.6) in all patients. After application of the vacuum, this was reduced to 1.2%. Before vacuum port use, 10 (31.3%) patients were not considered acceptable candidates for APBI because the SF/air volume:PTV_EVAL ratio (SF:PTV) was greater than 10% (range, 10.1-26.6%; median, 15.2%). After vacuum port use, the median SF:PTV ratio was 1.6% for a median reduction of 91.5%. In addition, the percentage of the prescribed dose covering greater than or equal to 90% of the PTV_EVAL proportionally increased a median of 8% (range, 3-10%) in eligible patients. Use of the Contura MLB vacuum port significantly improved the conformity of the target tissue to the balloon surface, leading to reproducible dose delivery and increased target volume coverage. In addition, application of the vacuum allowed the safe treatment of unacceptable patients with APBI. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Electron Cloud Measurements of Coated and Uncoated Vacuum Chambers in the CERN SPS by Means of the Microwave Transmission Method

    CERN Document Server

    Federmann, S; Mahner, E; Costa Pinto, P; Taborelli, M; Salvant, B; Seebacher, D; Yin Vallgren, C

    2010-01-01

    Electron cloud is a limitation to increasing the beam current in the CERN SPS in the frame of an intensity upgrade of the LHC complex. Coating the vacuum chamber with a thin amorphous carbon layer is expected to reduce the electron cloud build-up. Three SPS MBB magnets have been coated to study the performance of this carbon coating. The microwave transmission method is one possible way to monitor electron cloud and hence to test the effect of the coating. In this paper the evolution of the experimental setup for measurements of the electron cloud using LHC type beams will be described. Due to the low revolution frequency of about 43 kHz serious electromagnetic compatibility problems as well as intermodulation have been found. These effects and their mitigation are described. Finally, we present the measurement results illustrating the possible reduction due to the carbon coating.

  7. Windowless transition between atmospheric pressure and high vacuum via differential pumping for synchrotron radiation applications.

    Energy Technology Data Exchange (ETDEWEB)

    Gog, T.; Casa, D. M.; Kuzmenko, I.; Krakora, R. J.; Bolin, T. B.; X-Ray Science Division

    2007-07-01

    A differential pump assembly is introduced which can provide a windowless transition between the full atmospheric pressure of an in-air sample environment and the high-vacuum region of a synchrotron radiation beamline, while providing a clear aperture of approximately 1 mm to pass through the X-ray beam from a modern third-generation synchrotron radiation source. This novel pump assembly is meant to be used as a substitute for an exit vacuum window on synchrotron beamlines, where the existence of such a window would negatively impact the coherent nature of the X-ray beam or would introduce parasitic scattering, distorting weak scattering signals from samples under study. It is found that the length of beam pipe necessary to reduce atmospheric pressure to below 10 mbar is only about 130 mm, making the expected photon transmission for hard X-rays through this pipe competitive with that of a regular Be beamline window. This result is due to turbulent flow dominating the first pumping stage, providing a mechanism of strong gas conductance limitation, which is further enhanced by introducing artificial surface roughness in the pipe. Successive reduction of pressure through the transitional flow regime into the high-vacuum region is accomplished over a length of several meters, using beam pipes of increasing diameter. While the pump assembly has not been tested with X-rays, possible applications are discussed in the context of coherent and small-angle scattering.

  8. Short periodic applications of the vacuum-assisted closure device cause an extended tissue response in the diabetic mouse model.

    Science.gov (United States)

    Scherer, Sandra Saja; Pietramaggiori, Giorgio; Mathews, Jasmine C; Orgill, Dennis P

    2009-11-01

    The vacuum-assisted closure device is a widely used mechanical modulator of wound healing; however, the optimal time kinetics of application have not been determined. The objective of the study was to optimize the kinetics of vacuum-assisted closure application. Full-thickness wounds in seven diabetic mice per study group were treated with either an occlusive dressing alone, the vacuum-assisted closure device for 6 or 12 hours, or the vacuum-assisted closure device periodically for 4 hours every other day or continuously for 7 days. Wound closure and tissue response were evaluated by macroscopic, histologic, and immunohistochemical analyses on day 7. Wound closure was significantly faster after short initial vacuum-assisted closure (6-hour and 12-hour groups) when compared with continuous treatment. Increased granulation tissue formation was seen in the 12-hour group (2.4-fold increase) and in those treated periodically for 4 hours every other day (3.2-fold increase) compared with the dressing-alone controls. Significant stimulation of cell proliferation was seen after all vacuum-assisted closure patterns (3.6- to 5.3-fold increase), whereas angiogenesis was augmented only after the device was applied for either three times for 4 hours (4.3-fold) or continuously (4.7-fold) when compared with dressing-treated wounds. Treatment three times for 4 hours showed a superior angiogenic effect also when compared with short initial applications (6-hour and 12-hour groups). Short vacuum-assisted closure treatment induced an extended biological response in the wound. A total of 12 hours of periodically applied vacuum-assisted closure reached a similar wound tissue response as continuously applied vacuum-assisted closure for 7 days. These findings suggest new clinical approaches for mechanical wound-healing devices.

  9. DEVELOPING APPLICATIONS FOR ELECTRONIC BUSINESS

    Directory of Open Access Journals (Sweden)

    Georgeta Șoavă

    2012-12-01

    Full Text Available We are in the early 3rd millennium as companies face the need to exploit technology changing computer environments, in order to improve customer satisfaction and reduce costs. Thus, the development of e-business, the efficient use of new information technologies in business, by developing an alternative sales channel with relatively low costs, it manages to establish relationships with incomparably greater number of customers, to traditional approaches. Starting from these general considerations, we conducted this work we divided it into four parts. In the first part we present general context in which companies can achieve needs using new technologies, then we reviewed the basic elements in developing e-business type applications presenting their main benefits. Next, I approached refining models for e-business software development and use of distributed architectures for electronic commerce, concluding with a set of conclusions.

  10. Versatile, low-cost, computer-controlled, sample positioning system for vacuum applications

    Science.gov (United States)

    Vargas-Aburto, Carlos; Liff, Dale R.

    1991-01-01

    A versatile, low-cost, easy to implement, microprocessor-based motorized positioning system (MPS) suitable for accurate sample manipulation in a Second Ion Mass Spectrometry (SIMS) system, and for other ultra-high vacuum (UHV) applications was designed and built at NASA LeRC. The system can be operated manually or under computer control. In the latter case, local, as well as remote operation is possible via the IEEE-488 bus. The position of the sample can be controlled in three linear orthogonal and one angular coordinates.

  11. Generation of high charge state metal ion beams by electron cyclotron resonance heating of vacuum arc plasma in cusp trap.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Oks, E M; Vizir, A V; Yushkov, G Yu; Vodopyanov, A V; Izotov, I V; Mansfeld, D A

    2012-02-01

    A method for generating high charge state heavy metal ion beams based on high power microwave heating of vacuum arc plasma confined in a magnetic trap under electron cyclotron resonance conditions has been developed. A feature of the work described here is the use of a cusp magnetic field with inherent "minimum-B" structure as the confinement geometry, as opposed to a simple mirror device as we have reported on previously. The cusp configuration has been successfully used for microwave heating of gas discharge plasma and extraction from the plasma of highly charged, high current, gaseous ion beams. Now we use the trap for heavy metal ion beam generation. Two different approaches were used for injecting the vacuum arc metal plasma into the trap--axial injection from a miniature arc source located on-axis near the microwave window, and radial injection from sources mounted radially at the midplane of the trap. Here, we describe preliminary results of heating vacuum arc plasma in a cusp magnetic trap by pulsed (400 μs) high power (up to 100 kW) microwave radiation at 37.5 GHz for the generation of highly charged heavy metal ion beams.

  12. Justifying the Vacuum as an Electron-Positron Aggregation and Experimental Falsification

    Science.gov (United States)

    Guy Grantham, R.; Montgomery, Ian G.

    2013-09-01

    Historical aether models are placed in context with the electron-positron lattice (epola) model of space due to M. Simhony. A brief outline of the model as an aggregation state of matter, intermediate to the nuclear state and the atomic aggregation state, includes reference to its derivation of physical laws and fundamental constants. The broad application of the epola model is appraised for its validation against a range of physical laws, experiments and constants. Simhony declared a specific dependence for the stability of atomic matter upon speed through the epola, suggesting a test for falsification. This theme is further developed by the same logic to suggest practical experimental and theoretical tests of the epola model. A formula for the inverse fine structure constant of space, providing the accepted CODATA value, is derived from Simhony's explanation of the Bohr - de Broglie model of the ground state electron orbital of the hydrogen atom by including a term for speed through the Cosmos. A theoretical solution of the Michelson-Morley experiment is applied as evidence for the concept. The mechanism of motion through the epola is considered further for possible implications of speed including dependency of decay rates by radio nuclides and the results of former and ongoing experiments are considered.

  13. Structure, Mechanism, and Application of Vacuum Insulation Panels in Chinese Buildings

    Directory of Open Access Journals (Sweden)

    Changhai Peng

    2016-01-01

    Full Text Available Thermal insulation is one of the most used approaches to reduce energy consumption in buildings. Vacuum insulation panels (VIPs are new thermal insulation materials that have been used in the domestic and overseas market in the last 20 years. Due to the vacuum thermal insulation technology of these new materials, their thermal conductivity can be as low as 0.004 W/(m·K at the center of panels. In addition, VIPs that are composites with inorganic core and an envelope out of commonly three metallized PET layers and a PE sealing layer can provide B class fire resistance (their core materials are not flammable and are classified as A1. Compared with other conventional thermal insulation materials, the thermal insulation and fire resistance performances form the foundation of VIP’s applications in the construction industry. The structure and thermal insulation mechanism of VIP and their application potential and problems in Chinese buildings are described in detail.

  14. Vacuum circuit breaker modelling for the assessment of transient recovery voltages: application to various network configurations

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Borghetti, Alberto; Glasdam, Jakob Bærholm

    2018-01-01

    for both VCB sizing and insulation coordination studies of the components nearby the switching device. In this respect, their accurate modelling, which is the object of the paper, becomes crucial. In particular, the paper presents (the concept of) a VCB model and two relevant applications showing the model......Vacuum circuit breakers (VCBs) are widely used for medium voltage applications when low maintenance, long operating life, and large number of allowable switching cycles are required. The accurate estimation of the transient recovery voltages (TRVs) associated with their manoeuvres is indispensable...... capabilities of simulating TRVs due to opening/closing manoeuvres, namely the switching of large electrical motors and the switching of cables collecting offshore wind farms (OWFs). Data from digital fault recorder (DFR) in a water-pumping plant and from a measurement campaign in an OWF using a high...

  15. Applicability of Under Vacuum Fresh Tissue Sealing and Cooling to Omics Analysis of Tumor Tissues.

    Science.gov (United States)

    Veneroni, Silvia; Dugo, Matteo; Daidone, Maria Grazia; Iorio, Egidio; Valeri, Barbara; Pinciroli, Patrizia; De Bortoli, Maida; Marchesi, Edoardo; Miodini, Patrizia; Taverna, Elena; Ricci, Alessandro; Canevari, Silvana; Pelosi, Giuseppe; Bongarzone, Italia

    2016-12-01

    Biobanks of frozen human normal and malignant tissues represent a valuable source for "omics" analysis in translational cancer research and molecular pathology. However, the success of molecular and cellular analysis strongly relies on the collection, handling, storage procedures, and quality control of fresh human tissue samples. We tested whether under vacuum storage (UVS) effectively preserves tissues during the time between surgery and storage for "omics" analyses. Normal and matched tumor specimens, obtained from 16 breast, colon, or lung cancer patients and 5 independent mesenchymal tumors, were dissected within 20 minutes from surgical excision and divided in three to five aliquots; for each tissue sample, one aliquot was snap-frozen in liquid nitrogen (defined as baseline or T0 samples), and the other portions were sealed into plastic bags and kept at 4°C for 1, 24, 48, or 72 hours under vacuum and then frozen. The tissue and molecular preservation under vacuum was evaluated over time in terms of histomorphology, transcription (Illumina microarrays), protein (surface-enhanced laser desorption/ionization-time of flight/mass spectrometry and Western blot), and metabolic profile (nuclear magnetic resonance spectroscopy). Tissue morphology, Mib-1, and vimentin immunostaining were preserved over time without signs of tissue degradation. Principal variance component analysis showed that time of storage had a minimal effect on gene expression or the proteome, but affected the preservation of some metabolites to a greater extent. UVS did not impact the RNA and protein integrity or specific phosphorylation sites on mTOR and STAT3. Measurement of metabolites revealed pronounced changes after 1 hour of storage. Our results show that UVS can preserve tissue specimens for histological, transcriptomic, and proteomic examinations up to 48 hours and possibly longer, whereas it has limitations for metabolomic applications.

  16. Electron-molecule interactions and their applications

    CERN Document Server

    Christophorou, L G

    1984-01-01

    Electron-Molecule Interactions and Their Applications, Volume 2 provides a balanced and comprehensive account of electron-molecule interactions in dilute and dense gases and liquid media. This book consists of six chapters. Chapter 1 deals with electron transfer reactions, while Chapter 2 discusses electron-molecular positive-ion recombination. The electron motion in high-pressure gases and electron-molecule interactions from single- to multiple-collision conditions is deliberated in Chapter 3. In Chapter 4, knowledge on electron-molecule interactions in gases is linked to that on similar proc

  17. Electronic “Edge” State on Molybdenite Basal Plane Observed by Ultrahigh-Vacuum Scanning Tunneling Microscopy and Spectroscopy

    Science.gov (United States)

    Komiyama, Masaharu; Tomita, Hiroyuki; Yoda, Eisuke

    2007-09-01

    An electronic state heretofore unreported has been found on a cleaved basal plane of a natural molybdenite (MoS2) single crystal by ultrahigh-vacuum scanning tunneling microscopy (UHV-STM), and examined in detail both by STM and scanning tunneling spectroscopy (STS). The new electronic state resides on the edge of the upper terrace of MoS2(0001), manifesting itself in the form of bright ridges with a width of ca. 4 nm along the step edges in negatively sample-biased STM images. This ridge structure is nonexistent in STM images taken with positive sample biases. STS showed that the local density of states (LDOS) on such ridge structures is much higher than that on the terraces in the range of 0.2-1.2 eV below the Fermi edge. The nature and origin of this high LDOS at the step edges are discussed.

  18. Electron fluctuation induced resonance broadening in nano electromechanical systems: the origin of shear force in vacuum.

    Science.gov (United States)

    Siria, A; Barois, T; Vilella, K; Perisanu, S; Ayari, A; Guillot, D; Purcell, S T; Poncharal, P

    2012-07-11

    This article presents a study of the poorly understood "shear-force" used in an important class of near-field instruments that use mechanical resonance feedback detection. In the case of a metallic probe near a metallic surface in vacuum, we show that in the 10-60 nm range there is no such a thing as a shear-force in the sense of the nonconservative friction force. Fluctuations of the oscillator resonance frequency, likely induced by local charge variations, could account for the reported effects in the literature without introducing a dissipative force.

  19. Effect of vacuum polarization on the excitation of hydrogen atom by electron impact

    Directory of Open Access Journals (Sweden)

    Sujata Bhattacharyya

    1981-01-01

    for 1S−2S excitation of the hydrogen atom by electron impact. The excitation amplitude calculated field theoretically is found to be lowered by 0.47t2/(t2+93 where t2=4|P−Q|2, P and Q being the momenta of the incident and scattered electrons respectively.

  20. Flow injection of liquid samples to a mass spectrometer with ionization under vacuum conditions: a combined ion source for single-photon and electron impact ionization.

    Science.gov (United States)

    Schepler, Claudia; Sklorz, Martin; Passig, Johannes; Famiglini, Giorgio; Cappiello, Achille; Zimmermann, Ralf

    2013-09-01

    Electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo-ionization (APPI) are the most important techniques for the ionization of liquid samples. However, working under atmospheric pressure conditions, all these techniques involve some chemical rather than purely physical processes, and therefore, side reactions often yield to matrix-dependent ionization efficiencies. Here, a system is presented that combines both soft single-photon ionization (SPI) and hard 70 eV electron impact ionization (EI) of dissolved compounds under vacuum conditions. A quadrupole mass spectrometer was modified to enable direct EI, a technique developed by Cappiello et al. to obtain library-searchable EI mass spectra as well as soft SPI mass spectra of sample solutions. An electron beam-pumped rare gas excimer lamp working at 126 nm was used as well as a focusable vacuum UV light source for single-photon ionization. Both techniques, EI and SPI, were applied successfully for flow injection experiments providing library-matchable EI fragment mass spectra and soft SPI mass spectra, showing dominant signals for the molecular ion. Four model compounds were analyzed: hexadecane, propofol, chlorpropham, and eugenol, with detection limits in the picomolar range. This novel combination of EI and SPI promises great analytical benefits, thanks to the possibility of combining database alignment for EI data and molecular mass information provided by SPI. Possible applications for the presented ionization technology system are a matrix-effect-free detection and a rapid screening of different complex mixtures without time-consuming sample preparation or separation techniques (e.g., for analysis of reaction solutions in combinatorial chemistry) or a switchable hard (EI) and soft (SPI) MS method as detection step for liquid chromatography.

  1. Electrospun Polymer Fibers for Electronic Applications

    Science.gov (United States)

    Luzio, Alessandro; Canesi, Eleonora Valeria; Bertarelli, Chiara; Caironi, Mario

    2014-01-01

    Nano- and micro- fibers of conjugated polymer semiconductors are particularly interesting both for applications and for fundamental research. They allow an investigation into how electronic properties are influenced by size confinement and chain orientation within microstructures that are not readily accessible within thin films. Moreover, they open the way to many applications in organic electronics, optoelectronics and sensing. Electro-spinning, the technique subject of this review, is a simple method to effectively form and control conjugated polymer fibers. We provide the basics of the technique and its recent advancements for the formation of highly conducting and high mobility polymer fibers towards their adoption in electronic applications. PMID:28788493

  2. Electrospun Polymer Fibers for Electronic Applications

    Directory of Open Access Journals (Sweden)

    Alessandro Luzio

    2014-01-01

    Full Text Available Nano- and micro- fibers of conjugated polymer semiconductors are particularly interesting both for applications and for fundamental research. They allow an investigation into how electronic properties are influenced by size confinement and chain orientation within microstructures that are not readily accessible within thin films. Moreover, they open the way to many applications in organic electronics, optoelectronics and sensing. Electro-spinning, the technique subject of this review, is a simple method to effectively form and control conjugated polymer fibers. We provide the basics of the technique and its recent advancements for the formation of highly conducting and high mobility polymer fibers towards their adoption in electronic applications.

  3. Nanoscale Vacuum Channel Transistor.

    Science.gov (United States)

    Han, Jin-Woo; Moon, Dong-Il; Meyyappan, M

    2017-04-12

    Vacuum tubes that sparked the electronics era had given way to semiconductor transistors. Despite their faster operation and better immunity to noise and radiation compared to the transistors, the vacuum device technology became extinct due to the high power consumption, integration difficulties, and short lifetime of the vacuum tubes. We combine the best of vacuum tubes and modern silicon nanofabrication technology here. The surround gate nanoscale vacuum channel transistor consists of sharp source and drain electrodes separated by sub-50 nm vacuum channel with a source to gate distance of 10 nm. This transistor performs at a low voltage (3 microamperes). The nanoscale vacuum channel transistor can be a possible alternative to semiconductor transistors beyond Moore's law.

  4. Dosimetry for Electron Beam Applications

    DEFF Research Database (Denmark)

    Miller, Arne

    1983-01-01

    This report describes two aspects of electron bean dosimetry, on one hand developaent of thin fil« dosimeters and measurements of their properties, and on the other hand developaent of calorimeters for calibration of routine dosimeters, e.g. thin films. Two types of radiochromic thin film...

  5. Secondary Electron Yield Measurements of Fermilab?s Main Injector Vacuum Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Scott, D.J.; Capista, D.; Duel, K.L.; Zwaska, R.M.; /Fermilab; Greenwald, S.; Hartung, W.; Li, Y.; Moore, T.P.; Palmer, M.A.; /Cornell U.; Kirby, R.; Pivi, M.; /SLAC

    2012-05-01

    We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.

  6. Vacuum arc plasma deposition of thin titanium dioxide films on silicone elastomer as a functional coating for medical applications.

    Science.gov (United States)

    Boudot, Cécile; Kühn, Marvin; Kühn-Kauffeldt, Marina; Schein, Jochen

    2017-05-01

    Silicone elastomer is a promising material for medical applications and is widely used for implants with blood and tissue contact. However, its strong hydrophobicity limits adhesion of tissue cells to silicone surfaces, which can impair the healing process. To improve the biological properties of silicone, a triggerless pulsed vacuum cathodic arc plasma deposition technique was applied to deposit titanium dioxide (TiO2) films onto the surface. Scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy and contact angle measurements were used for coating characterization. Deposited films were about 150nm thick and exhibited good adhesion to the underlying silicone substrate. Surface wettability and roughness both increased after deposition of the TiO2 layer. In addition, cell-biological investigations demonstrated that the in-vitro cytocompatibility of TiO2-coated samples was greatly improved without impacting silicone's nontoxicity. For validation of use in medical devices, further investigations were conducted and demonstrated stability of surface properties in an aqueous environment for a period of 68days and the coating's resistance to several sterilization methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. First accelerator test of vacuum components with laser-engineered surfaces for electron-cloud mitigation

    Science.gov (United States)

    Calatroni, Sergio; Garcia-Tabares Valdivieso, Elisa; Neupert, Holger; Nistor, Valentin; Perez Fontenla, Ana Teresa; Taborelli, Mauro; Chiggiato, Paolo; Malyshev, Oleg; Valizadeh, Reza; Wackerow, Stefan; Zolotovskaya, Svetlana A.; Gillespie, W. Allan; Abdolvand, Amin

    2017-11-01

    Electron cloud mitigation is an essential requirement for high-intensity proton circular accelerators. Among other solutions, laser engineered surface structures (LESS) present the advantages of having potentially a very low secondary electron yield (SEY) and allowing simple scalability for mass production. Two copper liners with LESS have been manufactured and successfully tested by monitoring the electron cloud current in a dipole magnet in the SPS accelerator at CERN during the 2016 run. In this paper we report on these results as well as the detailed experiments carried out on samples—such as the SEY and topography studies—which led to an optimized treatment in view of the SPS test and future possible use in the HL-LHC.

  8. Failure behaviors of vacuum plasma sprayed tungsten coatings for plasma facing application

    Science.gov (United States)

    Chong, F. L.; Chen, J. L.; Li, J. G.; Zheng, X. B.

    2009-04-01

    About 1 mm vacuum plasma sprayed tungsten (VPS-W) coatings were fabricated on the copper chromium zirconium (CuCrZr) alloys substrate. The failure behaviors were studied by means of the steady state and transient heat load using the electron beam facility and the Nd: YAG laser, respectively. The results indicated that the columnar crystals grew up and then micro-cracks between the lamellar layers were observed. Macro-cracks and delamination appeared with the fatigue cycles increase. Finally, the coating failed. The surface cracks were also observed and propagated during the fatigue tests. The failure behaviors of the transient heat load are as follows: the homogeneous melting and micro-cracks, melting tungsten ejection which enhanced the erosion of tungsten due to the splash and evaporation. In addition, the physical properties of W coatings such as porosity, Vickers hardness were degraded. The roughing phenomenon was not easy to be observed due to the rough surface characteristic of VPS-W coatings.

  9. Power electronics handbook components, circuits and applications

    CERN Document Server

    Mazda, F F

    1993-01-01

    Power Electronics Handbook: Components, Circuits, and Applications is a collection of materials about power components, circuit design, and applications. Presented in a practical form, theoretical information is given as formulae. The book is divided into three parts. Part 1 deals with the usual components found in power electronics such as semiconductor devices and power semiconductor control components, their electronic compatibility, and protection. Part 2 tackles parts and principles related to circuits such as switches; link frequency chargers; converters; and AC line control, and Part 3

  10. The Study of Advanced Accelerator Physics Research at UCLA Using the ATF at BNL: Vacuum Acceleration by Laser of Free Electrons

    Energy Technology Data Exchange (ETDEWEB)

    Cline, David B. [Univ. of California, Los Angeles, CA (United States)

    2016-09-07

    An experiment was designed and data were taken to demonstrate that a tightly focused laser on vacuum can accelerate an electron beam in free space. The experiment was proof-of-principle and showed a clear effect for the laser beam off and on. The size of the effect was about 20% and was consistent over 30 laser and beam shots.

  11. The electronic states of 1,2,3-triazole studied by vacuum ultraviolet photoabsorption and ultraviolet photoelectron spectroscopy, and a comparison with ab initio configuration interaction methods

    DEFF Research Database (Denmark)

    Palmer, Michael H.; Hoffmann, Søren Vrønning; Jones, Nykola C.

    2011-01-01

    The Rydberg states in the vacuum ultraviolet photoabsorption spectrum of 1,2,3-triazole have been measured and analyzed with the aid of comparison to the UV valence photoelectron ionizations and the results of ab initio configuration interaction (CI) calculations. Calculated electronic ionization...

  12. The application of vacuum heat and thermo-chemical treatment to improve strength of different heavily loaded machine parts and engineering instruments

    OpenAIRE

    A. E. Smirnov; M. Yu. Semenov

    2014-01-01

    The paper was analyzes an application of vacuum equipment for heat and thermo-chemical treatment of aviation gear wheals, small bearings for aircraft equipment parts, and high strength stamps.The generalization of designed vacuum technologies of heat and thermo-chemical treatment results compared with traditional processes is accepted as objective of the paper.The practical use of vacuum processes (low pressure ones) has been first discussed in the specific context of the problem solution to ...

  13. Industrial Robot Automation in Solving Non-Vacuum Electron-Beam Welding Problems

    OpenAIRE

    Borovik Vasiliy; Shatravin Vladislav; Junusov Il’jas; Shashev Dmitri; Kornilov Sergei; Rempe Nikolai; Shidlovskiy Stanislav

    2016-01-01

    The paper describes one modeling automated hardware-software system to develop additive technologically - based products. Algorithm synthesis for industrial robot control was performed. In this case, the operating tool is an electron -beam projector with plasma emitter. The model testing results of thermal processes (in 3D-enqueuing) proceeding within additive substrate material system have been described. The modeling results revealed those required parameters of emission power which would p...

  14. Materials and applications of bioresorbable electronics

    Science.gov (United States)

    Huang, Xian

    2018-01-01

    Bioresorbable electronics is a new type of electronics technology that can potentially lead to biodegradable and dissolvable electronic devices to replace current built-to-last circuits predominantly used in implantable devices and consumer electronics. Such devices dissolve in an aqueous environment in time periods from seconds to months, and generate biological safe products. This paper reviews materials, fabrication techniques, and applications of bioresorbable electronics, and aims to inspire more revolutionary bioresorbable systems that can generate broader social and economic impact. Existing challenges and potential solutions in developing bioresorbable electronics have also been presented to arouse more joint research efforts in this field to build systematic technology framework. Project supported by the National Natural Science Foundation of China (No. 61604108) and the Natural Science Foundation of Tianjin (No. 16JCYBJC40600).

  15. Electron Beam Source for Technological Applications

    Science.gov (United States)

    Polyakov, V. A.; Shchedrin, I. S.

    1997-05-01

    Electron beam source with thermionic cathode and its application for technological purposes are described.Three electrode electron gun has a lanthanum hexaboride disc emitter with indirect heating. Accelerating voltage can be varied from 20 to 100 kV.Maximum d.c. current is 1-2 A for emitter diameter 4-5 mm.Magnetic focusing lens of solenoidal type ensures high beam power density on the object processed - up to 10 MW per sq.sm.This electron source was used for welding and thermoprocessing - surface hardening of ball-bearings. To ensure required complex power distribution on their surface special electronic unit for electron beam position control was designed.At the surface of ball-bearings the layer with hardness of 62-64 HRC and thickness about 1-1.5 mm was formed after electron processing that considerably increased their working period.

  16. Electronic Nose Technology and its Applications

    Directory of Open Access Journals (Sweden)

    Esmaeil MAHMOUDI

    2009-08-01

    Full Text Available In the past decade, Electronic Nose instrumentation has generated much interest internationally for its potential to solve a wide variety of problems in fragrance and cosmetics production, food and beverages manufacturing, chemical engineering, environmental monitoring and more recently medical diagnostic, bioprocesses and clinical diagnostic plant diseases. This instrument measure electrical resistance changes generated by adsorption of volatiles to the surface of electro active- polymer coated sensor- unique digital electronic fingerprint of aroma derived from multi-sensor- responses to distinct mixture of microbial volatiles. Major advances in information and gas sensor technology could enhance the diagnostic power of future bio-electronic nose and facilitate global surveillance mode of disease control and management. Several dozen companies are now designed and selling electronic nose units globally for a wide variety of expending markets. The present review includes principles of electronic nose technology, biosensor structure and applications of electronic nose in many fields.

  17. Thermal Insulation System for Non-Vacuum Applications Including a Multilayer Composite

    Science.gov (United States)

    Fesmire, James E. (Inventor)

    2017-01-01

    The thermal insulation system of the present invention is for non-vacuum applications and is specifically tailored to the ambient pressure environment with any level of humidity or moisture. The thermal insulation system includes a multilayered composite including i) at least one thermal insulation layer and at least one compressible barrier layer provided as alternating, successive layers, and ii) at least one reflective film provided on at least one surface of the thermal insulation layer and/or said compressible barrier layer. The different layers and materials and their combinations are designed to provide low effective thermal conductivity for the system by managing all modes of heat transfer. The thermal insulation system includes an optional outer casing surrounding the multilayered composite. The thermal insulation system is particularly suited for use in any sub-ambient temperature environment where moisture or its adverse effects are a concern. The thermal insulation system provides physical resilience against damaging mechanical effects including compression, flexure, impact, vibration, and thermal expansion/contraction.

  18. Phase equilibrium in system Ti-Si-C-B and synthesis of MAX phase layers in vacuum under the influence of electron beam

    Science.gov (United States)

    Smirnyagina, N. N.; Khaltanova, V. M.; Dasheev, D. E.; Lapina, A. E.

    2017-05-01

    Composite layers on the basis of carbides and borides the titan and silicon on titanic alloy VТ-1 are generated at diffused saturation by electron beam treatment in vacuum. Formation in a composite of MAX phase Ti3SiC2 is shown. Thermodynamic research of phase equilibrium in systems Ti-Si-C and Ti-B-C in the conditions of high vacuum is executed. The thermodynamics, formation mechanisms of superfirm layers borides and carbides of the titan and silicon are investigated.

  19. Industrial Robot Automation in Solving Non-Vacuum Electron-Beam Welding Problems

    Directory of Open Access Journals (Sweden)

    Borovik Vasiliy

    2016-01-01

    Full Text Available The paper describes one modeling automated hardware-software system to develop additive technologically - based products. Algorithm synthesis for industrial robot control was performed. In this case, the operating tool is an electron -beam projector with plasma emitter. The model testing results of thermal processes (in 3D-enqueuing proceeding within additive substrate material system have been described. The modeling results revealed those required parameters of emission power which would provide the melting of additive material (TiC excluding boiling.

  20. Pressure Model for the Vacuum System for the Electron Gun and Injector for LCLS Final Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Tung, L S; Eriksson, L

    2006-04-28

    The vacuum system of the injector for the Linac Coherent Light Source (LCLS) has been analyzed and configured by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. The vacuum system layout and detailed analyses for the injector are presented in this final design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated.

  1. Thermal Processing of Semiconductor Materials Using Soft-Vacuum Electron Beams.

    Science.gov (United States)

    Moore, Cameron Alden

    Electron beams generated in gaseous discharges have been used to perform a variety of thermal treatments germane to semiconductor fabrication. The unique beams employed in these studies are typified by high continuous power (>100 watts per cm^2 of cathode surface), operation in relatively high pressures (0.05-25 Torr), and a wide variety of beam configurations. The ability to extract and direct high power densities lends itself to the heat treatment of silicon-based semiconductor materials. Initial studies examined the rapid thermal processing of various materials and structures using a 7.5 cm. diameter electron beam. Using this source both the annealing of ion implanted single crystal silicon and the formation of titanium disilicide were performed. The repair of damage in single-crystal silicon wafers induced by ions of boron, phosphorus, and arsenic was repaired with minimum redistribution of the dopant profile. The same apparatus was also used to form titanium silicide from both co-deposited and sequentially deposited constituent materials. While low resistivity phases of both materials were obtained, each would exhibit high resistivity behavior as well. Excessive heating of co-deposited films on silicon dioxide induces reactions between the two films, causing oxygen to be incorporated in the silicide. Ti-on-Si structures self-cleanse oxygen from the silicide during formation, in contradiction to known Si-O and Ti-O thermodynamics. A line-source (150 mm x 2 mm) electron beam was used to recrystallize silicon films deposited on oxidized silicon wafers up to 100 mm in diameter. Agglomeration of the silicon while molten was prevented via the use of (i) an encapsulating silicon dioxide film, and (ii) the introduction of appropriate wetting agents into the deposited silicon during wafer preparation. A limiting constraint to the recrystallization of full wafers was the construction of a background heater which can heat the wafer to 1200 ^circC with a uniformity of

  2. Experimental and theoretical studies of vacuum-ultraviolet electronic circular dichroism of hydroxy acids in aqueous solution.

    Science.gov (United States)

    Fukuyama, Takayuki; Matsuo, Koichi; Gekko, Kunihiko

    2011-01-01

    The electronic circular dichroism (ECD) spectra of three L-hydroxy acids (L-lactic acid, (+)-(S)-2-hydroxy-3-methylbutyric acid, and (-)-(S)-2-hydroxyisocaproic acid) were measured down to 160 nm in aqueous solution using a vacuum-ultraviolet ECD spectrophotometer. To assign the two positive peaks around 210 and 175 nm and the one negative peak around 190 nm in the observed spectra, the ECD spectrum of L-lactic acid was calculated using time-dependent density functional theory (DFT) for the optimized structures by DFT and a continuum model. The observed ECD spectrum was successfully reproduced as the average spectrum for four optimized structures with seven water molecules that localized around the COO(-) and OH groups of L-lactic acid. The positive peak around 210 nm and the negative peak around 185 nm in the calculated spectrum were attributable to the nπ* transition of the carboxyl group, with the latter peak also being influenced by the ππ* transition of the carboxyl group; however, the positive peak around 165 nm involved unassignable higher energy transitions. The comparison of the calculated ECD spectra for L-lactic acid and L-alanine revealed that the network with loose hydrogen bonding around the COO(-) and OH groups is responsible for the flexible conformation of hydroxy acids and complicated side-chain dependence of ECD spectra relative to amino acids. Copyright © 2011 Wiley Periodicals, Inc.

  3. Experimental Evaluation and Comparison of Thermal Conductivity of High-Voltage Insulation Materials for Vacuum Electronic Devices

    Science.gov (United States)

    Suresh, C.; Srikrishna, P.

    2017-07-01

    Vacuum electronic devices operate with very high voltage differences between their sub-assemblies which are separated by very small distances. These devices also emit large amounts of heat that needs to be dissipated. Hence, there exists a requirement for high-voltage insulators with good thermal conductivity for voltage isolation and efficient heat dissipation. However, these voltage insulators are generally poor conductors of heat. In the present work, an effort has been made to obtain good high-voltage insulation materials with substantial improvement in their thermal conductivity. New mixtures of composites were formed by blending varying percentages (by volumes) of aluminum nitride powders with that of neat room-temperature vulcanizing (RTV) silicone elastomer compound. In this work, a thermal conductivity test setup has been devised for the quantification of the thermal conductivity of the insulators. The thermal conductivities and high-voltage isolation capabilities of various blended composites were quantified and were compared with that of neat RTV to evaluate the relative improvement.

  4. Adsorption geometry, conformation, and electronic structure of 2H-octaethylporphyrin on Ag(111) and Fe metalation in ultra high vacuum.

    Science.gov (United States)

    Borghetti, Patrizia; Di Santo, Giovanni; Castellarin-Cudia, Carla; Fanetti, Mattia; Sangaletti, Luigi; Magnano, Elena; Bondino, Federica; Goldoni, Andrea

    2013-04-14

    Due to the growing interest in the ferromagnetic properties of Fe-octaethylporphyrins (Fe-OEP) for applications in spintronics, methods to produce stable Fe-porphyrins with no Cl atoms are highly demanded. Here, we demonstrate the formation of Fe-OEP layers on Ag(111) single crystal by the ultra high vacuum in situ metalation of the free-base 2H-2,3,7,8,12,13,17,18-octaethylporphyrin (2H-OEP) molecules. The metalation proceeds exactly as in the case of 2H-5,10,15,20-tetraphenylporphyrin (2H-TPP) on the same substrate. An extensive surface characterization by means of X-ray photoemission spectroscopy, valence band photoemission, and NEXAFS with synchrotron radiation light provides information on molecular conformation and electronic structure in the monolayer and multilayer cases. We demonstrate that the presence of the ethyl groups affects the tilt of the adsorbed molecules, the conformation of the macrocycle, and the polarization screening in multilayers, but has only a minor effect in the metalation process with respect to 2H-TPP.

  5. Adsorption geometry, conformation, and electronic structure of 2H-octaethylporphyrin on Ag(111) and Fe metalation in ultra high vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Borghetti, Patrizia; Sangaletti, Luigi [I-LAMP and Department of Mathematics and Physics, Universita Cattolica del Sacro Cuore, Brescia (Italy); Santo, Giovanni Di; Castellarin-Cudia, Carla; Goldoni, Andrea [ST-INSTM micro- and nano-carbon lab., Elettra - Sincrotrone Trieste S.C.p.A., s.s.14 Km. 163.5, 34149 Trieste (Italy); Fanetti, Mattia [ST-INSTM micro- and nano-carbon lab., Elettra - Sincrotrone Trieste S.C.p.A., s.s.14 Km. 163.5, 34149 Trieste (Italy); Istituto Officina dei Materiali-CNR, Laboratorio TASC, s.s. 14 km 163.5, 34149 Trieste (Italy); Magnano, Elena; Bondino, Federica [Istituto Officina dei Materiali-CNR, Laboratorio TASC, s.s. 14 km 163.5, 34149 Trieste (Italy)

    2013-04-14

    Due to the growing interest in the ferromagnetic properties of Fe-octaethylporphyrins (Fe-OEP) for applications in spintronics, methods to produce stable Fe-porphyrins with no Cl atoms are highly demanded. Here, we demonstrate the formation of Fe-OEP layers on Ag(111) single crystal by the ultra high vacuum in situ metalation of the free-base 2H-2,3,7,8,12,13,17,18-octaethylporphyrin (2H-OEP) molecules. The metalation proceeds exactly as in the case of 2H-5,10,15,20-tetraphenylporphyrin (2H-TPP) on the same substrate. An extensive surface characterization by means of X-ray photoemission spectroscopy, valence band photoemission, and NEXAFS with synchrotron radiation light provides information on molecular conformation and electronic structure in the monolayer and multilayer cases. We demonstrate that the presence of the ethyl groups affects the tilt of the adsorbed molecules, the conformation of the macrocycle, and the polarization screening in multilayers, but has only a minor effect in the metalation process with respect to 2H-TPP.

  6. Applications for Energy Recovering Free Electron Lasers

    Energy Technology Data Exchange (ETDEWEB)

    George Neil

    2007-08-01

    The availability of high-power, high-brilliance sources of tunable photons from energy-recovered Free Electron Lasers is opening up whole new fields of application of accelerators in industry. This talk will review some of the ideas that are already being put into production, and some of the newer ideas that are still under development.

  7. Application of electron closures in extended MHD

    Science.gov (United States)

    Held, Eric; Adair, Brett; Taylor, Trevor

    2017-10-01

    Rigorous closure of the extended MHD equations in plasma fluid codes includes the effects of electron heat conduction along perturbed magnetic fields and contributions of the electron collisional friction and stress to the extended Ohms law. In this work we discuss application of a continuum numerical solution to the Chapman-Enskog-like electron drift kinetic equation using the NIMROD code. The implementation is a tightly-coupled fluid/kinetic system that carefully addresses time-centering in the advance of the fluid variables with their kinetically-computed closures. Comparisons of spatial accuracy, computational efficiency and required velocity space resolution are presented for applications involving growing magnetic islands in cylindrical and toroidal geometry. The reduction in parallel heat conduction due to particle trapping in toroidal geometry is emphasized. Work supported by DOE under Grant Nos. DE-FC02-08ER54973 and DE-FG02-04ER54746.

  8. 4D electron microscopy: principles and applications.

    Science.gov (United States)

    Flannigan, David J; Zewail, Ahmed H

    2012-10-16

    The transmission electron microscope (TEM) is a powerful tool enabling the visualization of atoms with length scales smaller than the Bohr radius at a factor of only 20 larger than the relativistic electron wavelength of 2.5 pm at 200 keV. The ability to visualize matter at these scales in a TEM is largely due to the efforts made in correcting for the imperfections in the lens systems which introduce aberrations and ultimately limit the achievable spatial resolution. In addition to the progress made in increasing the spatial resolution, the TEM has become an all-in-one characterization tool. Indeed, most of the properties of a material can be directly mapped in the TEM, including the composition, structure, bonding, morphology, and defects. The scope of applications spans essentially all of the physical sciences and includes biology. Until recently, however, high resolution visualization of structural changes occurring on sub-millisecond time scales was not possible. In order to reach the ultrashort temporal domain within which fundamental atomic motions take place, while simultaneously retaining high spatial resolution, an entirely new approach from that of millisecond-limited TEM cameras had to be conceived. As shown below, the approach is also different from that of nanosecond-limited TEM, whose resolution cannot offer the ultrafast regimes of dynamics. For this reason "ultrafast electron microscopy" is reserved for the field which is concerned with femtosecond to picosecond resolution capability of structural dynamics. In conventional TEMs, electrons are produced by heating a source or by applying a strong extraction field. Both methods result in the stochastic emission of electrons, with no control over temporal spacing or relative arrival time at the specimen. The timing issue can be overcome by exploiting the photoelectric effect and using pulsed lasers to generate precisely timed electron packets of ultrashort duration. The spatial and temporal resolutions

  9. Vacuum extraction

    DEFF Research Database (Denmark)

    Maagaard, Mathilde; Oestergaard, Jeanett; Johansen, Marianne

    2012-01-01

    Objectives. To develop and validate an Objective Structured Assessment of Technical Skills (OSATS) scale for vacuum extraction. Design. Two part study design: Primarily, development of a procedure-specific checklist for vacuum extraction. Hereafter, validationof the developed OSATS scale for vacuum...

  10. Vacuum Referred Binding Energy of the Single 3d, 4d, or 5d Electron in Transition Metal and Lanthanide Impurities in Compounds

    NARCIS (Netherlands)

    Rogers, E.G.; Dorenbos, P.

    2014-01-01

    The vacuum referred binding energy (VRBE) of the single electron in the lowest energy 3d level of Sc2 +, V4 +, Cr5 +, the lowest 4d level of Y2 +, Zr3 +, Nb4 +, Mo5 + and the lowest 5d level of Ta4 +, and W5 + in various compounds are determined by means of the chemical shift model. They will be

  11. Technology handbook of vacuum physics

    CERN Document Server

    Beck, A H

    2013-01-01

    Handbook of Vacuum Physics, Volume 3: Technology is part of a series of publications that presents articles featuring the whole spectrum of vacuum physics. This particular volume presents materials that deal with technology concerns in vacuum mechanics. The first material talks about the utilization of ceramic materials in the construction of vacuum devices. The next paper details the application of vacuum physics in soldering and brazing process. The last article deals with the utilization of vacuum technology in high frequency heating. The book will be of great use to professionals involved

  12. Tensile Behavior of Electron Beam-Welded and Post-Weld Vacuum-Annealed Nb-10% Hf-1% Ti Refractory Alloy Weldments

    Science.gov (United States)

    Anil Kumar, V.; Gupta, R. K.; Venkateswaran, T.; Ram Kumar, P.

    2018-01-01

    Nb-10% Hf-1% Ti refractory alloy is a high performance material extensively used for high temperature applications. Electron beam welding is one of the most widely used techniques to join refractory and reactive alloys. Bigger sizes of nozzles for rocket propulsion applications can be either made through deep drawing and flow turning route or by roll bending and welding route both using sheets/plates as input material for fabrication. The latter is a more economical option for mass production of the hardware using such exotic and expensive alloys. In view of this, both as-welded (AW) coupon and weld plus post-weld vacuum-annealed (AW + VA) coupon have been prepared to study their mechanical behavior. It has been observed that tensile strength and ductility have not been reduced in both these conditions vis-à-vis the base metal, confirming weld efficiency of the alloy to be 100%. Microhardness is found to be 150-160 VHN in the base metal and 200-225 VHN in the weld fusion zone in AW condition, which became uniform (145-155 VHN) throughout the weldment in AW + VA condition. Microstructure of the weldment in AW condition is found to be consisting of grains solidified by epitaxial mode from base metal toward the weld centre. In AW + VA condition, improvement in tensile elongation is observed, which is found to be due to the presence of homogenized grains/more uniform microstructure near the heat-affected zone as compared to the steep gradient in grain size in different zones in the weld in AW condition.

  13. Axial Vircator for Electronic Warfare Applications

    Directory of Open Access Journals (Sweden)

    L. Drazan

    2009-12-01

    Full Text Available This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered by magneto-cumulative generator and in weapons for defense of objects (WDO, it is powered by Marx generator. The possible applications of a vircator in the DEWM area are discussed.

  14. Applications of electron accelerator in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Khairul Zaman Hj. Mohd Dahlan [Malaysian Institute for Nuclear Technology Research (MINT), Bangi, Selangor Darul Ehsan (Malaysia)

    2003-02-01

    Current status of radiation processing, as one of the core research programs of the Malaysian Institute for Nuclear Technology Research (MINT), is presented. Industrial applications of six electron accelerators from 150 kV up to 3 MV in Malaysia now in operation are mainly for curing of surface coatings, crosslinking of tubes, heat shrinkable tubes and packaging films, crosslinking of wire insulation. Their performances are listed. New technology now in R and D stage includes natural rubber, sago starch and chitosan for biomedical applications, and radiation curable materials from oil palm for pressure sensitive adhesive and printing ink. (S. Ohno)

  15. Handbook of vacuum technology

    CERN Document Server

    2016-01-01

    This comprehensive, standard work has been updated to remain an important resource for all those needing detailed knowledge of the theory and applications of vacuum technology. With many numerical examples and illustrations to visualize the theoretical issues.

  16. Synaptic electronics: materials, devices and applications.

    Science.gov (United States)

    Kuzum, Duygu; Yu, Shimeng; Wong, H-S Philip

    2013-09-27

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented.

  17. The study of the modes of Ta-Zr powder mixture non-vacuum electron-beam cladding on the surface of the cp-titanium plates

    Science.gov (United States)

    Samoylenko, V. V.; Lozhkina, E. A.; Polyakov, I. A.; Lenivtseva, O. G.; Ivanchik, I. S.; Matts, O. E.

    2016-11-01

    The effect of the modes of non-vacuum electron-beam cladding of Ta-Zr powder mixtures on the structure and properties of the layers formed on the surface of cp-titanium were studied. The mode of the electron-beam alloying of titanium with zirconium and tantalum, which ensured the formation of a defect-free layer with a high content of alloying elements was selected. Metallographic examination indicated the presence of a dendritic- and plate-type structure of cladded layers. The microhardness of the layers, formed at the optimum mode, was not changed in the cross section and was equal to 450 HV.

  18. Power vacuum tubes handbook

    CERN Document Server

    Whitaker, Jerry

    2012-01-01

    Providing examples of applications, Power Vacuum Tubes Handbook, Third Edition examines the underlying technology of each type of power vacuum tube device in common use today. The author presents basic principles, reports on new development efforts, and discusses implementation and maintenance considerations. Supporting mathematical equations and extensive technical illustrations and schematic diagrams help readers understand the material. Translate Principles into Specific Applications This one-stop reference is a hands-on guide for engineering personnel involved in the design, specification,

  19. Stable, high quantum efficiency silicon photodiodes for vacuum-UV applications

    Science.gov (United States)

    Korde, Raj; Canfield, L. Randall; Wallis, Brad

    1988-01-01

    Silicon photodiodes have been developed by defect-free phosphorus diffusion having practically no carrier recombination at the SiSiO2 interface or in the front diffused region. The quantum efficiency of these photodiodes was found to be around 120 percent at 100 nm. Unlike the previously tested silicon photodiodes, the developed photodiodes exhibit extremely stable quantum efficiency over extended periods of time. The possibility of using these photodiodes as vacuum ultraviolet detector standards is being currently investigated.

  20. The Application of Vacuum-Assisted Closure Device in the Management of Empyema Necessitans

    Directory of Open Access Journals (Sweden)

    Yasser Aljehani

    2016-01-01

    Full Text Available Vacuum-assisted closure (VAC is gaining popularity in the management of many types of acute and chronic wounds. The use of VAC devices in thoracic surgery is limited, but it appears to be promising in complex cases of empyema thoraces. We report a case of empyema necessitans, in which VAC was used to achieve complete wound healing after open drainage which was communicating with the pleural space.

  1. Application of Vacuum-Assisted Closure Device in Management of Postpneumonectomy Empyema

    Science.gov (United States)

    Sohn, Suk Ho; Choi, Se Hoon; Kim, Young Tae

    2013-01-01

    A 57-year-old man was diagnosed with lung cancer and underwent pneumonectomy and mediastinal lymph node dissection. He was discharged without acute complications, but on a regular outpatient follow-up, he was readmitted with postpneumonectomy empyema. He was successfully treated with a vacuum-assisted closure device and for 1 year period of outpatient follow-up, there was no recurrence of empyema or lung cancer. PMID:23614105

  2. Development of a camera casing suited for cryogenic and vacuum applications

    Science.gov (United States)

    Delaquis, S. C.; Gornea, R.; Janos, S.; Lüthi, M.; von Rohr, Ch Rudolf; Schenk, M.; Vuilleumier, J.-L.

    2013-12-01

    We report on the design, construction, and operation of a PID temperature controlled and vacuum tight camera casing. The camera casing contains a commercial digital camera and a lighting system. The design of the camera casing and its components are discussed in detail. Pictures taken by this cryo-camera while immersed in argon vapour and liquid nitrogen are presented. The cryo-camera can provide a live view inside cryogenic set-ups and allows to record video.

  3. A modified ‘NanoSuit®’ preserves wet samples in high vacuum: direct observations on cells and tissues in field-emission scanning electron microscopy

    Science.gov (United States)

    Takaku, Yasuharu; Suzuki, Hiroshi; Kawasaki, Hideya; Ohta, Isao; Ishii, Daisuke; Hirakawa, Satoshi; Tsutsui, Takami; Matsumoto, Haruko; Takehara, Sayuri; Nakane, Chinatsu; Sakaida, Kana; Suzuki, Chiaki; Muranaka, Yoshinori; Kikuchi, Hirotoshi; Konno, Hiroyuki; Shimomura, Masatsugu

    2017-01-01

    Although field-emission scanning electron microscopy (FE-SEM) has proven very useful in biomedical research, the high vacuum required (10−3 to 10−7 Pa) precludes direct observations of living cells and tissues at high resolution and often produces unwanted structural changes. We have previously described a method that allows the investigator to keep a variety of insect larvae alive in the high vacuum environment of the electron microscope by encasing the organisms in a thin, vacuum-proof suit, the ‘NanoSuit®'. However, it was impossible to protect wet tissues freshly excised from intact organisms or cultured cells. Here we describe an improved ‘NanoSuit' technique to overcome this limitation. We protected the specimens with a surface shield enhancer (SSE) solution that consists of glycerine and electrolytes and found that the fine structure of the SSE-treated specimens is superior to that of conventionally prepared specimens. The SSE-based NanoSuit affords a much stronger barrier to gas and/or liquid loss than the previous NanoSuit did and, since it allows more detailed images, it could significantly help to elucidate the ‘real' organization of cells and their functions. PMID:28405375

  4. A modified 'NanoSuit®' preserves wet samples in high vacuum: direct observations on cells and tissues in field-emission scanning electron microscopy.

    Science.gov (United States)

    Takaku, Yasuharu; Suzuki, Hiroshi; Kawasaki, Hideya; Ohta, Isao; Ishii, Daisuke; Hirakawa, Satoshi; Tsutsui, Takami; Matsumoto, Haruko; Takehara, Sayuri; Nakane, Chinatsu; Sakaida, Kana; Suzuki, Chiaki; Muranaka, Yoshinori; Kikuchi, Hirotoshi; Konno, Hiroyuki; Shimomura, Masatsugu; Hariyama, Takahiko

    2017-03-01

    Although field-emission scanning electron microscopy (FE-SEM) has proven very useful in biomedical research, the high vacuum required (10-3 to 10-7 Pa) precludes direct observations of living cells and tissues at high resolution and often produces unwanted structural changes. We have previously described a method that allows the investigator to keep a variety of insect larvae alive in the high vacuum environment of the electron microscope by encasing the organisms in a thin, vacuum-proof suit, the 'NanoSuit®'. However, it was impossible to protect wet tissues freshly excised from intact organisms or cultured cells. Here we describe an improved 'NanoSuit' technique to overcome this limitation. We protected the specimens with a surface shield enhancer (SSE) solution that consists of glycerine and electrolytes and found that the fine structure of the SSE-treated specimens is superior to that of conventionally prepared specimens. The SSE-based NanoSuit affords a much stronger barrier to gas and/or liquid loss than the previous NanoSuit did and, since it allows more detailed images, it could significantly help to elucidate the 'real' organization of cells and their functions.

  5. Low energy electron diffraction (LEED) and sum frequency generation (SFG) vibrational spectroscopy studies of solid-vacuum, solid-air and solid-liquid interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, Saskia [Univ. of California, Berkeley, CA (United States)

    2002-01-01

    Electron based surface probing techniques can provide detailed information about surface structure or chemical composition in vacuum environments. The development of new surface techniques has made possible in situ molecular level studies of solid-gas interfaces and more recently, solid-liquid interfaces. The aim of this dissertation is two-fold. First, by using novel sample preparation, Low Energy Electron Diffraction (LEED) and other traditional ultra high vacuum (UHV) techniques are shown to provide new information on the insulator/vacuum interface. The surface structure of the classic insulator NaCl has been determined using these methods. Second, using sum frequency generation (SFG) surface specific vibrational spectroscopy studies were performed on both the biopolymer/air and electrode/electrolyte interfaces. The surface structure and composition of polyetherurethane-silicone copolymers were determined in air using SFG, atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). SFG studies of the electrode (platinum, gold and copper)/electrolyte interface were performed as a function of applied potential in an electrochemical cell.

  6. Indian Vacuum Society: The Indian Vacuum Society

    Science.gov (United States)

    Saha, T. K.

    2008-03-01

    The Indian Vacuum Society (IVS) was established in 1970. It has over 800 members including many from Industry and R & D Institutions spread throughout India. The society has an active chapter at Kolkata. The society was formed with the main aim to promote, encourage and develop the growth of Vacuum Science, Techniques and Applications in India. In order to achieve this aim it has conducted a number of short term courses at graduate and technician levels on vacuum science and technology on topics ranging from low vacuum to ultrahigh vacuum So far it has conducted 39 such courses at different parts of the country and imparted training to more than 1200 persons in the field. Some of these courses were in-plant training courses conducted on the premises of the establishment and designed to take care of the special needs of the establishment. IVS also regularly conducts national and international seminars and symposia on vacuum science and technology with special emphasis on some theme related to applications of vacuum. A large number of delegates from all over India take part in the deliberations of such seminars and symposia and present their work. IVS also arranges technical visits to different industries and research institutes. The society also helped in the UNESCO sponsored post-graduate level courses in vacuum science, technology and applications conducted by Mumbai University. The society has also designed a certificate and diploma course for graduate level students studying vacuum science and technology and has submitted a syllabus to the academic council of the University of Mumbai for their approval, we hope that some colleges affiliated to the university will start this course from the coming academic year. IVS extended its support in standardizing many of the vacuum instruments and played a vital role in helping to set up a Regional Testing Centre along with BARC. As part of the development of vacuum education, the society arranges the participation of

  7. Electronic structure theory: Applications and geometrical aspects

    Science.gov (United States)

    Coh, Sinisa

    This thesis contains several applications of the first-principles electronic-structure theory with special emphasis in parts of the thesis on the geometrical aspects of the theory. We start by reviewing the basics of the first-principles electronic-structure methods which are then used throughout the thesis. The first application of these methods is on the analysis of the stability and lattice dynamics of alpha- and beta-cristobalite phases of SiO2. We also map the complete low-energy landscape connecting these two structures and give implications on the phase transition in this compound. Next we study a family of Pbnm perovskites that are promising candidates for silicon-compatible high-K dielectrics. We calculate their structure and dielectric response, and compare with experimental results where available. The third application of these methods is to the large isosymmetric reorientation of oxygen octahedra rotation axes in epitaxially strained perovskites. We explain the origin of the peculiar energy landscape topology as a function of epitaxial strain. In the part of the thesis devoted to the geometrical aspects of electronic structure theory, we begin by extending the concept of electronic polarization to a Chern insulators. These insulators are characterized by a non-zero off-diagonal sigma_xy conductivity tensor component, quantized in units of e 2/h. Finally we discuss another geometrical quantity, the Chern-Simons orbital magnetoelectric coupling. We present a first-principles based calculation of this quantity in several compounds, and motivated by recent developments in the theory of topological insulators, we speculate about the existence of "large-theta materials," in which this kind of coupling could be unusually large.

  8. Electron cyclotron wave sources and applications for fusion

    Science.gov (United States)

    Thomassen, K. I.

    1990-03-01

    Advances in magnetic fusion research have come as often from the use of new technologies as from the invention of ideas and discovery of phenomena that are then applied to new experiments. The technologies needed for plasma production, heating, confinement, and control have largely been developed and are a major factor in the success of our current experiments. These include high vacuum techniques, normal and superconducting magnets, particle beams, pellet fueling devices, and rf sources in the ion cylotron and lower hybrid range of frequencies. One area where development is especially required, and where the potential impact on fusion research is large, is that of electron cyclotron wave (ECW) sources in the 100-600 GHz range. This journal issue is devoted to methods for ECW generation and transmission, and to applications including heating, current drive, profile shaping, and instability control. To help focus these articles the requirements(1) for a system to heat the Compact Ignition Tokamak (CIT) were used to define the necessary technology. Somewhat lower frequencies, but similar power, is anticipated(2) for the International Thermonuclear Experimental Reactor (ITER), and for future large devices of that class, should they use ECW sources in them.

  9. VACUUM TRAP

    Science.gov (United States)

    Gordon, H.S.

    1959-09-15

    An improved adsorption vacuum trap for use in vacuum systems was designed. The distinguishing feature is the placement of a plurality of torsionally deformed metallic fins within a vacuum jacket extending from the walls to the central axis so that substantially all gas molecules pass through the jacket will impinge upon the fin surfaces. T fins are heated by direct metallic conduction, thereby ol taining a uniform temperature at the adeorbing surfaces so that essentially all of the condensible impurities from the evacuating gas are removed from the vacuum system.

  10. Microwave receivers with electronic warfare applications

    CERN Document Server

    Tsui, James

    2005-01-01

    This book by the author of Digital Techniques for Wideband Receivers willbe like no other one on your book shelf as the definitive word on electronicwarfare (EW) receiver design and performance. Whether you are an EWscientist involved in the test and evaluation of EW receivers or a designerof RWR's and other EW-related receivers, Microwave Receivers withElectronic Warfare Applications is a handy reference through which you canperfect your technical art. Lucidly written, this book is a treatise on EWreceivers that is relevant to you if you are just looking for a top-levelinsight into EW receive

  11. Vacuum spin squeezing

    Science.gov (United States)

    Hu, Jiazhong; Chen, Wenlan; Vendeiro, Zachary; Urvoy, Alban; Braverman, Boris; Vuletić, Vladan

    2017-11-01

    We investigate the generation of entanglement (spin squeezing) in an optical-transition atomic clock through the coupling to an optical cavity in its vacuum state. We show that if each atom is prepared in a superposition of the ground state and a long-lived electronic excited state, and viewed as a spin-1/2 system, then the collective vacuum light shift entangles the atoms, resulting in a squeezed distribution of the ensemble collective spin, without any light applied. This scheme reveals that even an electromagnetic vacuum can constitute a useful resource for entanglement and quantum manipulation. By rotating the spin direction while coupling to the vacuum, the scheme can be extended to implement two-axis twisting resulting in stronger squeezing.

  12. High-vacuum optical platform for cryo-CLEM (HOPE): A new solution for non-integrated multiscale correlative light and electron microscopy.

    Science.gov (United States)

    Li, Shuoguo; Ji, Gang; Shi, Yang; Klausen, Lasse Hyldgaard; Niu, Tongxin; Wang, Shengliu; Huang, Xiaojun; Ding, Wei; Zhang, Xiang; Dong, Mingdong; Xu, Wei; Sun, Fei

    2018-01-01

    Cryo-correlative light and electron microscopy (cryo-CLEM) offers a unique way to analyze the high-resolution structural information of cryo-vitrified specimen by cryo-electron microscopy (cryo-EM) with the guide of the search for unique events by cryo-fluorescence microscopy (cryo-FM). To achieve cryo-FM, a trade-off must be made between the temperature and performance of objective lens. The temperature of specimen should be kept below devitrification while the distance between the objective lens and specimen should be short enough for high resolution imaging. Although special objective lens was designed in many current cryo-FM approaches, the unavoided frosting and ice contamination are still affecting the efficiency of cryo-CLEM. In addition, the correlation accuracy between cryo-FM and cryo-EM would be reduced during the current specimen transfer procedure. Here, we report an improved cryo-CLEM technique (high-vacuum optical platform for cryo-CLEM, HOPE) based on a high-vacuum optical stage and a commercial cryo-EM holder. The HOPE stage comprises of a special adapter to suit the cryo-EM holder and a high-vacuum chamber with an anti-contamination system. It provides a clean and enduring environment for cryo specimen, while the normal dry objective lens in room temperature can be used via the optical windows. The 'touch-free' specimen transfer via cryo-EM holder allows least specimen deformation and thus maximizes the correlation accuracy between cryo-FM and cryo-EM. Besides, we developed a software to perform semi-automatic cryo-EM acquisition of the target region localized by cryo-FM. Our work provides a new solution for cryo-CLEM and can be adapted for different commercial fluorescence microscope and electron microscope. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Applications of Canonical transformations and nontrivial vacuum solutions to flavor mixing and critical phenomena in quantum field theory

    Energy Technology Data Exchange (ETDEWEB)

    Mishchenko, Yuriy [North Carolina State Univ., Raleigh, NC (United States)

    2004-12-01

    MISHCHENKO, YURIY. Applications of Canonical Transformations and Nontrivial Vacuum Solutions to flavor mixing and critical phenomena in Quantum Field Theory. (Under the direction of Chueng-Ryong Ji.) In this dissertation we consider two recent applications of Bogoliubov Transformation to the phenomenology of quantum mixing and the theory of critical phenomena. In recent years quantum mixing got in the focus of the searches for New Physics due to its unparalleled sensitivity to SM parameters and indications of neutrino mixing. It was recently suggested that Bogoliubov Transformation may be important in proper definition of the flavor states that otherwise results in problems in perturbative treatment. As first part of this dissertation we investigate this conjecture and develop a complete formulation of such a mixing field theory involving introduction of general formalism, analysis of space-time conversion and phenomenological implications. As second part of this dissertati

  14. On Schwinger mechanics of electron-positron pair production from vacuum by the field of optical and x-ray laser

    CERN Document Server

    Popov, V S

    2001-01-01

    One calculated W probability of e sup + e sup - -pair production from vacuum under the effect of the intensive a-c field generated by optical or X-ray range lasers. One studied two peculiar ranges: gamma 1 and gamma 1, where gamma - parameter of adiabatic nature. It is shown that with rise of gamma, as well as, at transition from monochromatic radiation to finite duration laser pulse W probability increases abruptly (at similar value of field intensity). One discusses dependence of W probability and pulsed spectrum of electrons and positrons on the shape of laser pulse (the Schwinger dynamic effect)

  15. Characteristics of a miniature vacuum spark

    Science.gov (United States)

    Wong, C. S.; Ong, C. X.; Chin, O. H.; Lee, S.; Choi, P.

    1989-12-01

    The characteristics of a miniature vacuum spark device are investigated. It is powered by a 2-stage 50 kV Marx and operated without an external triggering source. Discharge initiation is effected by an electron beam produced by the Pseudospark effect behind the hollow cathode. For discharges performed in air at a pressure of below 10-2 mbar, intense X-ray is detected. Although this X-ray has been found to consist of predominantly the Fe-Kα line produced by the electron beam bombardment of the stainless steel anode, its high intensity, singly-pulsed short-duration temporal structure and nearly monochromatic spectrum make the present vacuum spark an ideal pulsed X-ray source for many applications. The device is also compact, low cost and easy to operate. As an example of its applications, the contact radiography of a living lizard has been obtained using this X-ray source.

  16. Heat resistant polymers for electronics applications

    Science.gov (United States)

    Sillion, B.; Verdet, L.

    This review looks at how the heat resistant polymers have become components of necessity in the building of electronic systems, starting with the fabrication of the integrated circuit, through its packaging, and concluding with its final assembly onto a circuit board. The specific material requirements for each application in terms of properties and processing and the response which has been given by the polymer chemist are discussed. An overview of the various classes of polymeric materials, which are used or considered for applications in the mentioned area, is provided. It includes linear and crosslinkable materials. Among linear thermostable polymers, some of them are offered as polyimide precursors, like conventional polyamic acids, as well as modified structures such as photoimagable polymers and alignment coatings for display tehcnologies. However, fully cyclized soluble materials such as polyimides or polyphenylquinoxalines are now considered when better dielectric properties are needed. Applications of crosslinkable resins such as maleimides, benzocyclobutenes and acetylenics are also reviewed. The respective benefits of these different materials in relationship with their structure are examined.

  17. Effect of drying methods with the application of vacuum microwaves on the bioactive compounds, color, and antioxidant activity of strawberry fruits.

    Science.gov (United States)

    Wojdyło, Aneta; Figiel, Adam; Oszmiański, Jan

    2009-02-25

    The objective of this study was to evaluate the application of vacuum-microwave drying (240, 360, and 480 W) in the production process of dehydrated strawberry and to compare and contrast the quality of these dehydrated strawberries in terms of their polyphenol compounds, concentration of some heat liable components, and color to that of freeze-dried, convective, and vacuum-dried strawberry. Thus, the effect of vacuum-microwave drying and other drying methods on the antioxidant activity of berries was evaluated. Whole fresh and dried fruits were assessed for phenolics (anthocyanins, flavanols, hydroxycinnamic acids, and flavonols), ascorbic acid, and antioxidant activity (all parameters were calculated on a dry matter basis). Analysis of data shows that ellagic acid and flavanol changes were affected by drying techniques and cultivar. Drying destroyed anthocyanins, flavanols, and ascorbic acid, and there was a significant decrease in antioxidant activity. The most striking result was that conventional and vacuum drying decreased antioxidant activity in both cultivars, whereas contradictory results were found for vacuum-microwave processed strawberry. This study has demonstrated that vacuum-microwave drying, especially at 240 W, can produce high-quality products, with the additional advantage of reduced processing times, compared to other processes such as freeze-drying.

  18. Invariant vacuum

    Science.gov (United States)

    Robles-Pérez, Salvador

    2017-11-01

    We apply the Lewis-Riesenfeld invariant method for the harmonic oscillator with time dependent mass and frequency to the modes of a charged scalar field that propagates in a curved, homogeneous and isotropic spacetime. We recover the Bunch-Davies vacuum in the case of a flat DeSitter spacetime, the equivalent one in the case of a closed DeSitter spacetime and the invariant vacuum in a curved spacetime that evolves adiabatically. In the three cases, it is computed the thermodynamical magnitudes of entanglement between the modes of the particles and antiparticles of the invariant vacuum, and the modification of the Friedmann equation caused by the existence of the energy density of entanglement. The amplitude of the vacuum fluctuations are also computed.

  19. Cosmic vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Chernin, Artur D [P.K. Shternberg State Astronomical Institute at the M.V. Lomonosov Moscow State University, Moscow (Russian Federation)

    2001-11-30

    Recent observational studies of distant supernovae have suggested the existence of cosmic vacuum whose energy density exceeds the total density of all the other energy components in the Universe. The vacuum produces the field of antigravity that causes the cosmological expansion to accelerate. It is this accelerated expansion that has been discovered in the observations. The discovery of cosmic vacuum radically changes our current understanding of the present state of the Universe. It also poses new challenges to both cosmology and fundamental physics. Why is the density of vacuum what it is? Why do the densities of the cosmic energy components differ in exact value but agree in order of magnitude? On the other hand, the discovery made at large cosmological distances of hundreds and thousands Mpc provides new insights into the dynamics of the nearby Universe, the motions of galaxies in the local volume of 10 - 20 Mpc where the cosmological expansion was originally discovered. (reviews of topical problems)

  20. Novel technique of creating a seal for the vacuum-assisted closure system application in complex head and neck wounds.

    Science.gov (United States)

    Tian, Brian; Iyer, N Gopalakrishna; Tan, Hiang Khoon; Tay, Ai Choo; Soo, Khee Chee; Tan, Ngian Chye

    2016-12-01

    Achieving a good seal for the application of the vacuum-assisted closure (VAC) system in complex head and neck wounds is difficult. A case series of 4 patients who developed postoperative orocutaneous or pharyngocutaneous fistulas were studied. A sterile green glove was used as a sealant together with the VAC system. With utilization of a green glove, a good seal for the VAC system was obtained. This gave ample time to cleanse the wound and allow granulation tissue to form before proceeding on to the next stage of treatment. A green glove technique allows for a good seal for the VAC system to work, especially when applied to complex head and neck wounds. © 2016 Wiley Periodicals, Inc. Head Neck 38: E2523-E2526, 2016. © 2016 Wiley Periodicals, Inc.

  1. [Advances in the research of application of vacuum-assisted closure in wound healing and its mechanism].

    Science.gov (United States)

    Xie, S L; Guo, G H; Min, D H

    2017-06-20

    As a new generation of negative pressure drainage technology, vacuum-assisted closure (VAC) can provide stable and persistent negative pressure, and there are several modes to choose from. VAC plays an important role in closing wounds quickly, controlling infection, promoting angiogenesis, increasing blood flow, and promoting granulation tissue growth of wounds. It is now widely applied in all kinds of acute, chronic, and special wounds in clinic with good therapeutic results. However, we need to pay attention to contraindications and complications of VAC when it is used, avoiding secondary damage due to improper treatment. In this review, we summarize VAC dressings, treating pressure and mode choice, mechanism in promoting wound healing, and clinical application of VAC.

  2. Vacuum II

    CERN Document Server

    Franchetti, G

    2013-01-01

    This paper continues the presentation of pumps begun in ‘Vacuum I’. The main topic here is gauges and partial-pressure measurements. Starting from the kinetics of gases, the various strategies for measuring vacuum pressures are presented at an introductory level, with some reference to hardware devices. Partial-pressure measurement techniques are introduced, showing that the principles of ion selection have a direct similarity to particle dynamics in accelerators.

  3. 21 CFR 1311.120 - Electronic prescription application requirements.

    Science.gov (United States)

    2010-04-01

    ... prescription information to medical records. (22) If the transmission of an electronic prescription fails, the... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Electronic prescription application requirements... REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Electronic Prescriptions § 1311.120...

  4. Intrinsically shunted Josephson junctions for electronics applications

    Science.gov (United States)

    Belogolovskii, M.; Zhitlukhina, E.; Lacquaniti, V.; De Leo, N.; Fretto, M.; Sosso, A.

    2017-07-01

    Conventional Josephson metal-insulator-metal devices are inherently underdamped and exhibit hysteretic current-voltage response due to a very high subgap resistance compared to that in the normal state. At the same time, overdamped junctions with single-valued characteristics are needed for most superconducting digital applications. The usual way to overcome the hysteretic behavior is to place an external low-resistance normal-metal shunt in parallel with each junction. Unfortunately, such solution results in a considerable complication of the circuitry design and introduces parasitic inductance through the junction. This paper provides a concise overview of some generic approaches that have been proposed in order to realize internal shunting in Josephson heterostructures with a barrier that itself contains the desired resistive component. The main attention is paid to self-shunted devices with local weak-link transmission probabilities that are so strongly disordered in the interface plane that transmission probabilities are tiny for the main part of the transition region between two super-conducting electrodes, while a small part of the interface is well transparent. We discuss the possibility of realizing a universal bimodal distribution function and emphasize advantages of such junctions that can be considered as a new class of self-shunted Josephson devices promising for practical applications in superconducting electronics operating at 4.2 K.

  5. Comparison of intraocular pressure during the application of a liquid patient interface (FEMTO LDV Z8) for femtosecond laser-assisted cataract surgery using two different vacuum levels.

    Science.gov (United States)

    Ebner, Martina; Mariacher, Siegfried; Januschowski, Kai; Boden, Katrin; Seuthe, Anna-Maria; Szurman, Peter; Boden, Karl Thomas

    2017-08-01

    To evaluate intraocular pressure (IOP) using the application of a novel liquid patient interface for femtosecond laser-assisted cataract surgery with the FEMTO LDV Z8. IOP was evaluated in enucleated porcine eyes prior, during and after the application of the Femto LDV Z8 liquid patient interface (Ziemer Ophthalmic Systems, Switzerland) using intracameral cannulation (n=20), intravitreal cannulation (n=20), rebound tonometry (n=20) and indentation tonometry (n=20). Pressure was assessed prior vacuum, during vacuum (30 s, 1 min, 2 min, 3 min) and after releasing the vacuum (1 min and 2 min). Two groups with different predefined vacuum levels (350 mbar, 420 mbar) were investigated. Mean intracameral pressure (±SD) increased during vacuum application from 20 mm Hg to 52.00 mm Hg (±6.35mm Hg; p=0.005) and 45.18 mmHg (±4.34 mm Hg; p=0.005) for the 420 mbar and the 350 mbar vacuum levels, respectively. Mean intravitreal pressure increased from 20 mm Hg to 25.60 mm Hg (±9.85 mm Hg; p=0.058) and 28.10 mm Hg (±2.54 mm Hg; p=0.059) for the 420 mbar and the 350 mbar vacuum levels, respectively. Pressure values from indentation and rebound tonometry were in between intracameral and intravitreal values. Mean intracameral IOP was 18.1% higher (p=0.019) in the 420 mbar group compared with the 350 mbar group. During vacuum application of the liquid patient interface of the Femto LDV Z8 for femtosecond laser-assisted cataract surgery, IOP values were higher in the anterior chamber compared with the intravitreal pressure measurements. The higher predefined vacuum level (350 mbar vs 420 mbar) resulted in significant higher intracameral IOP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Low-energy electron beams through ultra-thin foils, applications for electron microscopy

    NARCIS (Netherlands)

    Van Aken, R.H.

    2005-01-01

    This thesis has discussed two electron microscopy applications that make use of ultra-thin foils: the tunnel junction emitter and the low-energy foil corrector. Both applications have in common that the electron beam is sent through the thin foil at low energy. Part of the electrons will scatter in

  7. Optimized demineralization of human cancellous bone by application of a vacuum.

    Science.gov (United States)

    Eagle, Mark J; Rooney, Paul; Kearney, John N

    2015-07-01

    Human demineralized bone matrix derived from cortical bone is used by surgeons due to its ability to promote bone formation. There is also a need for shaped demineralized bone matrices made from cancellous bone, where the properties of the material allow its insertion into defects, therefore acting as a void filler and scaffold onto which new bone can form. In this study, we report that demineralized bone sponges were prepared by dissecting and cutting knee bone into cancellous bone cubes of 1 cm(3) . These cubes were then taken through a series of warm water washes, some with sonication, centrifugation, and two decontamination chemical washes. The cubes were optimally demineralized into sponges with 0.5N hydrochloric acid under vacuum with constant pH measurement. Demineralization was confirmed by quantitative measurement of calcium and qualitatively by compression. The sponges were freeze dried before terminal sterilisation with a target dose of 25 kGy gamma radiation whilst frozen. Samples of the sponges were histologically examined for calcium and collagen and also tested for osteoinductivity. Data showed well defined collagen staining in the sponges, with little residual calcium. Sponges from two out of three donors demonstrated osteoinductivity when implanted into the muscle of an athymic mouse. © 2014 Wiley Periodicals, Inc.

  8. Experimental study of the reduction of field emission by gas injection in vacuum for accelerator applications

    Directory of Open Access Journals (Sweden)

    K. Almaksour

    2014-10-01

    Full Text Available Field emission current from surfaces under vacuum and at high field strengths can be reduced by the injection of gas into the evacuated volume. In this paper, the effects of H_{2}, He, N_{2}, and Ar on this “dark” current emitted from a tungsten carbide point cathode for 2 cm gap distance is studied. Exposure to any of these gases at pressures on the order of 10^{−3}–10^{−2}  Pa was found to reduce the emission current by up to 90% with a time constant on the order of ∼1  minute as compared to the current at 10^{−6}  Pa. The effect was strongly dependent on the gas nature, with Ar and N_{2} having larger effects at lower pressures than He and H_{2}. The reduction was reversible, with the current increasing to near its original value with a time constant on the order of ∼1–10  minutes after pumping down. The effect of the gas remained in the absence of electric field, whatever the gas pressure. Mechanisms for these and related phenomena are discussed.

  9. Experimental study of the reduction of field emission by gas injection in vacuum for accelerator applications

    Science.gov (United States)

    Almaksour, K.; Kirkpatrick, M. J.; Dessante, Ph.; Odic, E.; Simonin, A.; de Esch, H. P. L.; Lepetit, B.; Alamarguy, D.; Bayle, F.; Teste, Ph.

    2014-10-01

    Field emission current from surfaces under vacuum and at high field strengths can be reduced by the injection of gas into the evacuated volume. In this paper, the effects of H2, He, N2, and Ar on this "dark" current emitted from a tungsten carbide point cathode for 2 cm gap distance is studied. Exposure to any of these gases at pressures on the order of 10-3-10-2 Pa was found to reduce the emission current by up to 90% with a time constant on the order of ˜1 minute as compared to the current at 10-6 Pa. The effect was strongly dependent on the gas nature, with Ar and N2 having larger effects at lower pressures than He and H2. The reduction was reversible, with the current increasing to near its original value with a time constant on the order of ˜1-10 minutes after pumping down. The effect of the gas remained in the absence of electric field, whatever the gas pressure. Mechanisms for these and related phenomena are discussed.

  10. Power electronic converters and systems frontiers and applications

    CERN Document Server

    Trzynadlowski, Andrzej M

    2016-01-01

    Power electronics is a branch of electrical engineering dealing with conversion and control of electric power using semiconductor power switches. This book provides an overview of modern power electronic converters and systems, and their applications.

  11. Industrial application of electron sources with plasma emitters

    CERN Document Server

    Belyuk, S I; Rempe, N G

    2001-01-01

    Paper contains a description, operation, design and parameters of electron sources with plasma emitters. One presents examples of application of these sources as part of automated electron-beam welding lines. Paper describes application of such sources for electron-beam deposition of composite powders. Electron-beam deposition is used to rebuild worn out part and to increase strength of new parts of machines and tools. Paper presents some examples of rebuilding part and the advantages gained in this case

  12. A rotating quantum vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Lorenci, V.A. de; Svaiter, N.F. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    1996-11-01

    It was investigated which mapping has to be used to compare measurements made in a rotating frame to those made in an inertial frame. Using a non-Galilean coordinate transformation, the creation-annihilation operators of a massive scalar field in the rotating frame are not the same as those of an inertial observer. This leads to a new vacuum state(a rotating vacuum) which is a superposition of positive and negative frequency Minkowski particles. Polarization effects in circular accelerators in the proper frame of the electron making a connection with the inertial frame point of view were analysed. 65 refs.

  13. Electrospun Fibers for Energy, Electronic, & Environmental Applications

    Science.gov (United States)

    Bedford, Nicholas M.

    applications, fibers consisting of the commonly used organic photovoltaic electron donor/acceptor pair P3HT:PCBM were made by coaxial electrospinning. The inclusion of P3HT:PCBM fibers into an active layer of a organic photovoltaic device led to a ˜ 50% increase in power conversion efficiency over a thin film device of identical chemical composition and thickness. The inclusion of biological photosynthetic moieties into electrically relevant conjugated polymers was also explored for electrical applications. Polymeric fibers consisting largely of PEDOT:PSS were doped with thylakoid vesicles from spinach, and were found to act as photo-detectors. Native PEDOT:PSS does not exhibit such properties. For environmental applications, photocatalytic degradation membranes were also created by electrospinning cellulosic fibers which could be used as platforms to efficiently bind the photocatalyst TiO2. Employing different fiber-titania binding strategies, titania nanoparticles of various sizes and band gap configurations were successfully incorporated into mats of non-woven cellulosic nanofibers. These mats were found to successfully degrade dyes and relevant fresh water toxins such as microcystin-LR.

  14. Analysis of the effect of the Electron-Beam welding sequence for a fixed manufacturing route using finite element simulations applied to ITER vacuum vessel manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Martín-Menéndez, Cristina, E-mail: cristina@natec-ingenieros.com [Numerical Analysis Technologies, S.L. Marqués de San Esteban No. 52, 33206 Gijón (Spain); Rodríguez, Eduardo [Department of Mechanical Engineering, University of Oviedo, Campus de Gijón, 33203 Gijón (Spain); Ottolini, Marco [Ansaldo Nucleare S.p.A., Corso Perrone 25, 16152 Genova (Italy); Caixas, Joan [F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Guirao, Julio [Numerical Analysis Technologies, S.L. Marqués de San Esteban No. 52, 33206 Gijón (Spain)

    2016-03-15

    Highlights: • The simulation methodology employed in this paper is able to adapt inside a complex manufacturing route. • The effect of the sequence is lower in a highly constrained assembly than in a lowly constrained one. • The most relevant influence on the distortions is the jigs design, instead of the welding sequence. • The welding distortion analysis should be used as a guidance to design and improve the manufacturing strategy. - Abstract: The ITER Vacuum Vessel Sectors have very tight tolerances and high density of welding. Therefore, prediction and reduction of welding distortion are critical to allow the final assembly with the other Vacuum Vessel Sectors without the production of a full scale prototype. In this paper, the effect of the welding sequence in the distortions inside a fixed manufacturing route and in a highly constrained assembly is studied in the poloidal segment named inboard (PS1). This is one of the four poloidal segments (PS) assembled for the sector. Moreover, some restrictions and limitations in the welding sequence related to the manufacturing process are explained. The results obtained show that the effect of the sequence is lower in a highly constrained assembly than in a low constrained one. A prototype manufactured by AMW consortium (PS1 mock-up) is used in order to validate the finite element method welding simulation employed. The obtained results confirmed that for Electron-Beam welds, both the welding simulation and the mock-up show a low value of distortions.

  15. Right Ventricular Perforation From a Floating Rib Following Deep Sternal Wound Infection Debridement and Application of a Vacuum-Assisted Closure Device: A Case Report and Literature Review.

    Science.gov (United States)

    Ross, Amanda J; Berry, Nada N

    2017-01-01

    Introduction: Deep sternal wound infection following major cardiac surgery is a deleterious complication with sequelae that can be life threatening. The use of vacuum-assisted closure therapy in management of sternal wounds with resultant right ventricular rupture has been documented in the cardiothoracic and to a lesser extent in the reconstructive literature. Methods/Case Report: We present a case of a 67-year-old male patient who suffered from right ventricular perforation from a floating rib following debridement of a deep sternal wound infection and placement of a vacuum-assisted closure device. Results: Despite meticulous debridement and ensuring the release of all retrosternal adhesions, massive bleeding was encountered shortly after application of the vacuum-assisted closure device. Fortunately, quick identification of the complication and the application of direct manual pressure allowed for swift return to the operating room for repair of the defect. The patient secondarily underwent definitive closure of the mediastinal wound with an omental flap and bilateral pectoral advancement flaps. Discussion: Following the conclusion of this article, the reconstructive surgeon should be able to (1) identify patients at risk for ventricular perforation, (2) exhaust all means intraoperatively to prevent cardiac perforation when using vacuum-assisted closure therapy, (3) comprehend the physiology associated with vacuum-assisted closure use in this patient population, (4) have protocols in place for the management of patients with deep sternal wound infection with vacuum-assisted closure therapy postoperatively, and (5) understand basic tenets of ventricular rupture treatment should this occur to ensure prompt repair and survival.

  16. Synergistic Formation of Radicals by Irradiation with Both Vacuum Ultraviolet and Atomic Hydrogen: A Real-Time In Situ Electron Spin Resonance Study

    CERN Document Server

    Ishikawa, Kenji; Kono, Akihiko; Horibe, Hideo; Takeda, Keigo; Kondo, Hiroki; Sekine, Makoto; Hori, Masaru; 10.1021/jz2002937

    2012-01-01

    We report on the surface modification of polytetrafluoroethylene (PTFE) as an example of soft- and bio-materials that occur under plasma discharge by kinetics analysis of radical formation using in situ real-time electron spin resonance (ESR) measurements. During irradiation with hydrogen plasma, simultaneous measurements of the gas-phase ESR signals of atomic hydrogen and the carbon dangling bond (C-DB) on PTFE were performed. Dynamic changes of the C-DB density were observed in real time, where the rate of density change was accelerated during initial irradiation and then became constant over time. It is noteworthy that C-DBs were formed synergistically by irradiation with both vacuum ultraviolet (VUV) and atomic hydrogen. The in situ real-time ESR technique is useful to elucidate synergistic roles during plasma surface modification.

  17. Vacuum Technology for Superconducting Devices

    CERN Document Server

    Chiggiato, P

    2014-01-01

    The basic notions of vacuum technology for superconducting applications are presented, with an emphasis on mass and heat transport in free molecular regimes. The working principles and practical details of turbomolecular pumps and cryopumps are introduced. The specific case of the Large Hadron Collider’s cryogenic vacuum system is briefly reviewed.

  18. Nanostructures for Electronic and Sensing Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project will develop sensors and electronic components from metal oxide based nanotubes and nanowires. These nanostructured materials will be grown...

  19. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  20. Hexavalent Chrome Free Coatings for Electronics Applications: Joint Test Report

    Science.gov (United States)

    Rothgeb, Matt; Kessel, Kurt

    2013-01-01

    The overall objective of the Hexavalent Chrome Free Coatings for Electronics Applications project is to evaluate and test pretreatments not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders.

  1. Applications and advances in electronic-nose technologies

    Science.gov (United States)

    A. D. Wilson; M. Baietto

    2009-01-01

    Electronic-nose devices have received considerable attention in the field of sensor technology during the past twenty years, largely due to the discovery of numerous applications derived from research in diverse fields of applied sciences. Recent applications of electronic nose technologies have come through advances in sensor design, material improvements, software...

  2. CERN's web application updates for electron and laser beam technologies

    CERN Document Server

    Sigas, Christos

    2017-01-01

    This report describes the modifications at CERN's web application for electron and laser beam technologies. There are updates at both the front and the back end of the application. New electron and laser machines were added and also old machines were updated. There is also a new feature for printing needed information.

  3. Advances in Electronic Commerce, Web Application and Communication v.2

    CERN Document Server

    Lin, Sally; Second International Conference on Electronic Commerce, Web Application and Communication (ECWAC 2012)

    2012-01-01

    ECWAC2012 is an integrated conference devoted to Electronic Commerce, Web Application and Communication. In the this proceedings you can find the carefully reviewed scientific outcome of the second International Conference on Electronic Commerce, Web Application and Communication (ECWAC 2012) held at March 17-18,2012  in Wuhan, China, bringing together researchers from all around the world in the field.

  4. Advances in Electronic Commerce, Web Application and Communication v.1

    CERN Document Server

    Lin, Sally; Second International Conference on Electronic Commerce, Web Application and Communication (ECWAC 2012)

    2012-01-01

    ECWAC2012 is an integrated conference devoted to Electronic Commerce, Web Application and Communication. In the this proceedings you can find the carefully reviewed scientific outcome of the second International Conference on Electronic Commerce, Web Application and Communication (ECWAC 2012) held at March 17-18,2012  in Wuhan, China, bringing together researchers from all around the world in the field.

  5. R&D ERL: Vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Mapes, M.; Smart, L.; Weiss, D.; Steszyn, A.; Todd, R.

    2010-01-01

    The ERL Vacuum systems are depicted in a figure. ERL has eight vacuum volumes with various sets of requirements. A summary of vacuum related requirements is provided in a table. Five of the eight volumes comprise the electron beamline. They are the 5-cell Superconducting RF Cavity, Superconducting e-gun, injection, loop and beam dump. Two vacuum regions are the individual cryostats insulating the 5-cell Superconducting RF Cavity and the Superconducting e-gun structures. The last ERL vacuum volume not shown in the schematic is the laser transport line. The beamline vacuum regions are separated by electropneumatic gate valves. The beam dump is common with loop beamline but is considered a separate volume due to geometry and requirements. Vacuum in the 5-cell SRF cavity is maintained in the {approx}10{sup -9} torr range at room temperature by two 20 l/s ion pumps and in the e-gun SRF cavity by one 60 l/s ion pump. Vacuum in the SRF cavities operated at 2{sup o}K is reduced to low 10{sup -11} torr via cryopumping of the cavity walls. The cathode of the e-gun must be protected from poisoning, which can occur if vacuum adjacent to the e-gun in the injection line exceeds 10-11 torr range in the injection warm beamline near the e-gun exit. The vacuum requirements for beam operation in the loop and beam dump are 10-9 torr range. The beamlines are evacuated from atmospheric pressure to high vacuum level with a particulate free, oil free turbomolecular pumping cart. 25 l/s shielded ion pumps distributed throughout the beamlines maintain the vacuum requirement. Due to the more demanding vacuum requirement of the injection beamline proximate to the e-gun, a vacuum bakeout of the injection beamline is required. In addition, two 200 l/s diode ion pumps and supplemental pumping provided by titanium sublimation pumps are installed in the injection line just beyond the exit of the e-gun. Due to expected gas load a similar pumping arrangement is planned for the beam dump. The

  6. Comparative analysis of Trichuris muris surface using conventional, low vacuum, environmental and field emission scanning electron microscopy

    National Research Council Canada - National Science Library

    Lopes Torres, Eduardo José; de Souza, Wanderley; Miranda, Kildare

    2013-01-01

    .... The morphology of Trichuris spp. and other helminths has been mostly studied using conventional scanning electron microscopy of chemically fixed, dried and metal-coated specimens, although this kind of preparation has been shown...

  7. AN APPLICATION OF ELECTRONIC AMPLIFIER STETHOSCOPE

    Directory of Open Access Journals (Sweden)

    Alper KAÇAR

    2014-05-01

    Full Text Available Electronic stethoscopes are one of the important medical devices which affects the self-diagnostic or remote diagnostic in medical area. Rather the general stethoscopes, electronic ones increases the sound amplitude and quality. By filtering ambient noise, they can be used for advance analysis of heart or lung related diseases.

  8. Advances in vacuum ultraviolet detection with multistep gaseous detectors and application to Cherenkov ring imaging

    CERN Document Server

    Breskin, Amos; Charpak, Georges; Peisert, Anna; Policarpo, Armando; Sauli, Fabio

    1981-01-01

    The multistep avalanche chamber permits an efficient detection of VUV photons. In a two-step proportional mode charges higher than 1 pC are obtained from single electrons. By using as the final localization step a spark chamber viewed by a TV digitizer it is easy to have imaging of complex patterns. This is applied to Cherenkov ring imaging and (K, pi ) separation with 3 sigma up to 320 GeV is envisaged. The properties of various photoionizable vapours have been studied. By combining a scintillation xenon chamber with a photoionization wire chamber, a resolution of 8.3% (FWHM) has been obtained for 5.9 keV X- rays using tetrakis(dimethylamine)-ethylene vapour. (15 refs).

  9. Polycystalline silicon thin films for electronic applications

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, Christian Claus

    2012-01-15

    with an activation energy of E{sub A}{sup poly-Si}=1.1 eV. By long-lasting tempering or a short high-temperature step finally the stable layer configuration substrate/Al+Si islands(hillocks)/poly-Si can be reached (E{sub A}{sup hillocks}=2.4 eV). The further main topic of this thesis is the study of the applicability of the poly-silicon layers fabricated by means of the ALILE and R-ALILE process for electronic applications. First thin-film transistors were studied. Additionally thin-film solar cells with microcrystalline silicon as absorber material on polycrystalline R-ALILE seed layers were fabricated. Finally the suitedness of the fabricated poly-silicon layers for crytographic applications were studied.

  10. Vacuum Arc Ion Sources

    CERN Document Server

    Brown, I.

    2013-12-16

    The vacuum arc ion source has evolved into a more or less standard laboratory tool for the production of high-current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. Applications include primarily ion implantation for material surface modification research, and good performance has been obtained for the injection of high-current beams of heavy-metal ions, in particular uranium, into particle accelerators. As the use of the source has grown, so also have the operational characteristics been improved in a variety of different ways. Here we review the principles, design, and performance of vacuum arc ion sources.

  11. Handbook of vacuum physics

    CERN Document Server

    1964-01-01

    Handbook of Vacuum Physics, Volume 3: Technology is a handbook of vacuum physics, with emphasis on the properties of miscellaneous materials such as mica, oils, greases, waxes, and rubber. Accurate modern tables of physical constants, properties of materials, laboratory techniques, and properties of commercial pumps, gauges, and leak detectors are presented. This volume is comprised of 12 chapters and begins with a discussion on pump oils, divided into rotary pump oils and vapor pump oils. The next chapter deals with the properties and applications of greases, including outgassing and vapor pr

  12. The application of vacuum heat and thermo-chemical treatment to improve strength of different heavily loaded machine parts and engineering instruments

    Directory of Open Access Journals (Sweden)

    A. E. Smirnov

    2014-01-01

    Full Text Available The paper was analyzes an application of vacuum equipment for heat and thermo-chemical treatment of aviation gear wheals, small bearings for aircraft equipment parts, and high strength stamps.The generalization of designed vacuum technologies of heat and thermo-chemical treatment results compared with traditional processes is accepted as objective of the paper.The practical use of vacuum processes (low pressure ones has been first discussed in the specific context of the problem solution to design hardening technologies for critical parts from complex alloyed steels with exclusive operational properties. To solve this problem by traditional methods is impossible.The research techniques included the complex combination of experimental studies conducted using an industrial universal vacuum furnace of SECO/WARWICK S.A. company (Poland, and of metallographic exams and mechanic tests as well as of numerical simulations accomplished by original vacuum carburizing (nitrocarburizing models.The study objects were as follows:a steels containing chromium, nickel, molybdenum, tungsten and vanadium, which were used for gear wheals. In particular, a precipitation-hardening steel 13Kh3N3M2VFB was for the first time applied at carburized (nitrocarburized condition;b Steel 8Kh4V9F2, which was used for bearing rings;c Steel Kh12MF, which was used for stamps.The following operation properties are critical for gears: high contact fatigue endurance on the pitch circle; high bending fatigue endurance on the gears tooth-root; wear resistance on entire surface. Designing the technological operating conditions is complicated due to need to combine high values of all these properties, which stipulate the little-compatible requirements for physical and phase composition of the diffusion layers. Due to the advantages of thermo-chemical vacuum processes in oxygen-free atmosphere, namely technological flexibility and high reproducibility, the aperiodic cycles of

  13. Vacuum circuit breaker modelling for the assessment of transient recovery voltages: application to various network configurations

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Borghetti, Alberto; Glasdam, Jakob Bærholm

    2017-01-01

    for both VCB sizing and insulation coordination studies of the components nearby the switching device. In this respect, their accurate modelling, which is the object of the paper, becomes crucial. In particular, the paper presents (the concept of) a VCB model and two relevant applications showing the model......-bandwidth GPS-synchronised measurement system, respectively, are used for model validation. It is shown that the inclusion of detailed VCB models significantly improves the agreement between the measurements related to both pre- and restrikes and the corresponding simulation results obtained by using two well...

  14. Pristine fullerenes mixed by vacuum-free solution process: Efficient electron transport layer for planar perovskite solar cells

    Science.gov (United States)

    Dai, Si-Min; Tian, Han-Rui; Zhang, Mei-Lin; Xing, Zhou; Wang, Lu-Yao; Wang, Xin; Wang, Tan; Deng, Lin-Long; Xie, Su-Yuan; Huang, Rong-Bin; Zheng, Lan-Sun

    2017-01-01

    Discovery of organic-inorganic hybrid perovskites ignites the dream of next-generation solar cells fabricated by low-cost solution processing. To date, fullerene derivative [6,6]-phenyl-C61- butyric acid methyl ester (PC61BM), is the most prevalently used electron transport layer for high efficiency p-i-n planar heterojunction perovskite solar cells. Compared with PC61BM, pristine fullerenes, such as C60 and C70, have shown superiority of higher electron mobility and much lower costs. Due to the poor solubility and strong tendency to crystallize for pristine fullerenes in solution process, it is still a challenge to deposit compact and continuous film of pristine fullerenes for p-i-n type perovskite solar cells by solution processing. Herein, solution processed pristine fullerenes (C60 and C70) were used as electron transport layers to replace PC61BM in perovskite solar cells with high performance and enhanced stability. Power conversion efficiency of 14.04% was obtained by using mixture of C60 and C70 as electron transport layer, which is comparable to that of PC61BM based device (13.74%). We demonstrated that the strong tendency of pristine fullerenes to crystallize during solvent removal can be largely mitigated by mixing different kinds of pristine fullerenes. These findings implicate pristine fullerenes as promising electron transport layers for high performance perovskite solar cells.

  15. Gases and vacua handbook of vacuum physics

    CERN Document Server

    Beck, A H

    2013-01-01

    Handbook of Vacuum Physics, Volume 1: Gases and Vacua provides information on the many aspects of vacuum technology, from material on the quantum theoretical aspects of the complex semi-conductors used for thermionic and photo-electric emission to data on the performance of commercially available pumps, gauges, and high-vacuum materials. The handbook satisfies the need of workers using vacuum apparatuses or works on the diverse applications of high-vacuum technology in research and industry. The book is a compilation of long articles prepared by experts in vacuum technology. Sufficient theoret

  16. The extension of shelf-life of chicken meat after application of caraway and anise essential oils and vacuum packaging

    Directory of Open Access Journals (Sweden)

    Maciej Kluz

    2016-01-01

    Full Text Available Normal 0 21 false false false SK X-NONE X-NONE The effect of caraway (CEO and anise (AEO essential oils as well as vacuum packaging (VP in extending of the shelf life of fresh chicken breast meat stored at 4 °C was investigated. CEO and AEO were used at concentrations 0.2% v/w with and without VP. Microbiological properties of chicken breast meat were monitored over a 16 day period. The microbiological parameters as the anaerobic plate count (AC, Enterobacteraceae, lactic acid bacteria and Pseudomonas spp. counts were detected. The anaerobic plate counts ranged from 2.77 log cfu.g-1 in all tested group on 0 day to 5.45 log cfu.g-1 on 16 day in control group stored in air condition. The number of lactic acid bacteria ranged from 3.20 log cfu.g-1 in all tested group on 0 day to 4.75 log cfu.g-1 on 16 day in control group stored in air condition. Enterobacteriaceae counts ranged from 0.00 to 4.25 log cfu.g-1 on 16 day in control group stored in air condition. The number of Pseudomonas spp. ranged from 0.00 log cfu.g-1 in all tested group on 0 day to 2.65 log cfu.g-1 on 16 day in control group stored in air condition. Statistically significant differences (P≤0.001 were found among tested group in all tested microorganisms. Among the antimicrobial combination treatments were examined in the study, the as application of vacuum packaging, EDTA, and essential oils were the most effective against the growth of lactic acid bacteria and Enterobactericeae and to a less extent on anaerobic plate count. The results of this present study suggest the possibility of using the essential oil of caraway and anise as natural food preservatives and potential source of antimicrobial ingredients for chicken breast meat.

  17. An application of vacuum insulated tubing (VIT) in a SAGD thermal completion at Surmont

    Energy Technology Data Exchange (ETDEWEB)

    Handfield, T.C.; Martin, W.; Spenceley, N. [ConocoPhillips (Canada); Banman, R.M. [Total EandP (Canada)

    2011-07-01

    In the oil sands industry, steam assisted gravity drainage (SAGD) is a thermal recovery method. During the preheating of an SAGD well pair, high quality steam is injected down hole through the long string while return fluids are returned to the surface through the short string; this situation leads to unwanted heat exchanges between the two. The aim of the study is to determine the possible benefits of using acuum insulated tubing (VIT), a technology which manages downhole temperature successfully, in the SAGD process. A theoretical analysis and a field test were conducted on 2 injection wells in an in-situ oil sands project in Surmont in the Athabasca area. Results showed that the use of VIT improves heat transfer efficiency, leading to lower steam injection requirements and a reduction of concerns relating to thermal expansion and well integrity. This paper demonstrated that the application of VIT to the SAGD process is beneficial.

  18. Freeform Compliant CMOS Electronic Systems for Internet of Everything Applications

    KAUST Repository

    Shaikh, Sohail F.

    2017-01-17

    The state-of-the-art electronics technology has been an integral part of modern advances. The prevalent rise of the mobile device and computational technology in the age of information technology offers exciting applications that are attributed to sophisticated, enormously reliable, and most mature CMOS-based electronics. We are accustomed to high performance, cost-effective, multifunctional, and energy-efficient scaled electronics. However, they are rigid, bulky, and brittle. The convolution of flexibility and stretchability in electronics for emerging Internet of Everything application can unleash smart application horizon in unexplored areas, such as robotics, healthcare, smart cities, transport, and entertainment systems. While flexible and stretchable device themes are being remarkably chased, the realization of the fully compliant electronic system is unaddressed. Integration of data processing, storage, communication, and energy management devices complements a compliant system. Here, a comprehensive review is presented on necessity and design criteria for freeform (physically flexible and stretchable) compliant high-performance CMOS electronic systems.

  19. Simulation of Vacuum UV Absorption and Electronic Circular Dichroism Spectra of Methyl Oxirane: the Role of Vibrational Effects

    Science.gov (United States)

    Hodecker, Manuel; Biczysko, Malgorzata; Dreuw, Andreas; Barone, Vincenzo

    2017-01-01

    Vibrationally resolved one-photon absorption and electronic circular dichroism spectra of (R)-methyl oxirane were calculated with different electronic and vibronic models selecting, through an analysis of the convergence of the results, the best compromise between reliability and computational cost. Linear-response TD-DFT/CAM-B3LYP/SNST electronic computations in conjunction with the simple vertical gradient vibronic model were chosen and employed for systematic comparison with the available experimental data. Remarkable agreement between simulated and experimental spectra was achieved for both one photon absorption and circular dichroism concerning peak positions, relative intensities, and general spectral shapes considering the computational efficiency of the chosen theoretical approach. The significant improvement of the results with respect to smearing of vertical electronic transitions by phenomenological Gaussian functions and the possible inclusion of solvent effects by polarizable continuum models at a negligible additional cost paves the route toward the simulation and analysis of spectral shapes of complex molecular systems in their natural environment. PMID:27159495

  20. Expressions for Neutrino Wave Functions and Transition Probabilities at Three-Neutrino Oscillations in Vacuum and Some of Their Applications

    CERN Document Server

    Beshtoev, K M

    2006-01-01

    I have considered three-neutrino vacuum transitions and oscillations in the general case and obtained expressions for neutrino wave functions in three cases: with $CP$ violation, without $CP$ violation and in the case when direct $\

  1. Ferroelectric emission studies for electron emission lithography applications.

    Science.gov (United States)

    Yoo, In K; Ryu, Sang O; Suchicital, Carlos T A; Lee, June K; Kim, Byong M; Chung, Chee W

    2003-10-01

    Ferroelectric switching emission, dielectric switching emission, and pyroelectric emission were studied by patterning images on electron resist for electron emission lithography applications. It was observed that the pyroelectric emission is most acceptable for a high throughput 1:1 electron projection lithography application. A 1:1 electron projection lithography was demonstrated by patterning images with line widths of 30 microm and using pyroelectric emission. A degradation of the pyroelectric emission property of the material was observed during repeated heating cycles below the phase-transition temperature of the ferroelectric material. Annealing excursions above the phase transition temperature prevented the degradation of the pyroelectric emitter.

  2. High field electron paramagnetic resonance spectroscopy under ultrahigh vacuum conditions—A multipurpose machine to study paramagnetic species on well defined single crystal surfaces

    Science.gov (United States)

    Rocker, J.; Cornu, D.; Kieseritzky, E.; Seiler, A.; Bondarchuk, O.; Hänsel-Ziegler, W.; Risse, T.; Freund, H.-J.

    2014-08-01

    A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of the resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic

  3. High field electron paramagnetic resonance spectroscopy under ultrahigh vacuum conditions—A multipurpose machine to study paramagnetic species on well defined single crystal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rocker, J.; Cornu, D.; Kieseritzky, E.; Hänsel-Ziegler, W.; Freund, H.-J. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Seiler, A. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Laboratorium für Applikationen der Synchrotronstrahlung, KIT Campus Süd, Kaiserstr. 12, 76131 Karlsruhe (Germany); Bondarchuk, O. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); CIC energiGUNE, Parque Tecnologico, C/Albert Einstein 48, CP 01510 Minano (Alava) (Spain); Risse, T., E-mail: risse@chemie.fu-berlin.de [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Institut für Chemie und Biochemie, Freie Universität Berlin, Takustr. 3, 14195 Berlin (Germany)

    2014-08-01

    A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of the resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic

  4. Microminiature thermionic vacuum flat panel display prototype

    Energy Technology Data Exchange (ETDEWEB)

    Sadwick, L.P.; Baker, B.; Chen, C.C.; Petersen, R.; Johnson, S.; Hwu, R.J. [Univ. of Utah, Salt Lake City, UT (United States). Dept. of Electrical Engineering

    1996-12-31

    The authors report on the fabrication and electrical characteristics of low work microminiature thermionic vacuum (MTV) diodes for use in flat panel display applications. In this work advances in the technology and performance of a novel thermionic analog to field emission vacuum microelectronic emitters that will be referred to by the descriptive name microminiature thermionic vacuum (MTV) emitters will be presented. The salient feature of MTV emitter technology is the use of an air-bridge (suspended) filament that greatly reduces the thermal load and stress on the system. MTV devices can be fabricated using conventional semiconductor and micromachining processing techniques on any thermally stable, vacuum compatible substrate for which a high temperature stable insulating layer can be grown or deposited on. In addition, the small (micron to sub-micron) distances between the cathode and anode allow the possibility of intrinsic operation to high frequencies comparable to that of field emitters since these devices will not suffer from solid-state electron transport effects that limit the upper frequency of operation for all semiconductor devices.

  5. Analysis of the possibility of performing microminiature low-voltage electron devices for vacuum millimeter-wavelength integral circuit

    Science.gov (United States)

    Gulyaev, Yuri V.; Nefyodov, I. S.; Nechaev, A. V.; Sinitsyn, Nickolay I.; Torgashov, Gennadii V.; Zakharchenko, Yu. F.; Zhbanov, A. I.

    1994-08-01

    The output characteristics of a strip distributed microwave (MW) power amplifier tuned by voltage in a wide frequency range analyzed. New energy collector designs are proposed to be employed in the amplifier in the form of a periodically nonuniform strip line and electron optical system comprising an electron gun with the multi-edge field emitter array current modulator. Their electrodynamic and current parameters have been calculated by rigorous methods. The analysis of the output amplitude-frequency characteristics of the amplifier was performed. It is shown that, unlike the previously reported amplifier design, it can allow for a higher gain in the short-wavelength region of centimeter band, including the millimeter band, or operate at substantially lower beam currents.

  6. Application of a grating coupler for surface plasmon polariton excitation in a photoemission electron microscopy experiment

    DEFF Research Database (Denmark)

    Leißner, Till; Jauernik, Stephan; Lemke, Christoph

    Surface plasmon polariton (SPP) excitation at a gold-vacuum interface via 800 nm light pulses mediated by a periodic array of gold ridges is probed at high lateral resolution by means of photoemission electron microscopy (PEEM). We directly monitor and quantify the coupling properties as a function...... to the grazing incidence excitation geometry intrinsic to a conventional PEEM scheme and the limited propagation distance of the SPP modes at the gold-vacuum interface at the used wavelength....

  7. Crystal Structure, Optical, and Electrical Properties of SnSe and SnS Semiconductor Thin Films Prepared by Vacuum Evaporation Techniques for Solar Cell Applications

    Science.gov (United States)

    Ariswan; Sutrisno, H.; Prasetyawati, R.

    2017-05-01

    Thin films of SnSe and SnS semiconductors had been prepared by vacuum evaporation techniques. All prepared samples were characterized on their structure, optical, and electrical properties in order to know their application in technology. The crystal structure of SnSe and SnS was determined by X-Ray Diffraction (XRD) instrument. The morphology and chemical composition were obtained by Scanning Electron Microscopy (SEM) coupled with Energy Dispersive of X-Ray Analysis (EDAX). The optical property such as band gap was determined by DR-UV-Vis (Diffuse Reflectance-Ultra Violet-Visible) spectroscopy, while the electrical properties were determined by measuring the conductivity by four probes method. The characterization results indicated that both SnSe and SnS thin films were polycrystalline. SnSe crystallized in an orthorhombic crystal system with the lattice parameters of a = 11.47 Å, b = 4.152 Å and c = 4.439 Å, while SnS had an orthorhombic crystal system with lattice parameters of a = 4.317 Å, b = 11.647 Å and c = 3.981 Å. Band gaps (Eg) of SnSe and SnS were 1.63 eV and 1.35 eV, respectively. Chemical compositions of both thin films were non-stoichiometric. Molar ratio of Sn : S was close to ideal which was 1 : 0.96, while molar ratio of Sn : S was 1 : 0.84. The surface morphology described the arrangement of the grains on the surface of the thin film with sizes ranging from 0.2 to 0.5 microns. Color similarity on the surface of the SEM images proved a homogenous thin layer.

  8. Ferrite nanoparticles: Synthesis, characterisation and applications in electronic device

    Energy Technology Data Exchange (ETDEWEB)

    Kefeni, Kebede K., E-mail: kkefeni@gmail.com; Msagati, Titus A.M.; Mamba, Bhekie B.

    2017-01-15

    Highlights: • Available synthesis methods of ferrite nanoparticles (FNPs) are briefly reviewed. • Summary of the advantage and limitation of FNPs synthesis techniques are presented. • The existing most common FNPs characterisation techniques are briefly reviewed. • Major application areas of FNPs in electronic materials are reviewed. - Abstract: Ferrite nanoparticles (FNPs) have attracted a great interest due to their wide applications in several areas such as biomedical, wastewater treatment, catalyst and electronic device. This review focuses on the synthesis, characterisation and application of FNPs in electronic device with more emphasis on the recently published works. The most commonly used synthesis techniques along with their advantages and limitations are discussed. The available characterisation techniques and their application in electronic materials such as sensors and biosensors, energy storage, microwave device, electromagnetic interference shielding and high-density recording media are briefly reviewed.

  9. Power electronic converter systems for direct drive renewable energy applications

    DEFF Research Database (Denmark)

    Chen, Zhe

    2013-01-01

    This chapter presents power electronic conversion systems for wind and marine energy generation applications, in particular, direct drive generator energy conversion systems. Various topologies are presented and system design optimization and reliability are briefly discussed....

  10. Electronic Health Services: An Introduction to Theory and Application

    African Journals Online (AJOL)

    Information and communication technologies have made dramatic changes in our lives. Healthcare communities also made use of these technologies. Using computerized medical knowledge, electronic patients' information and telecommunications a lot of applications are now established throughout the world.

  11. Electronic Nose Technology and its Applications

    OpenAIRE

    Esmaeil MAHMOUDI

    2009-01-01

    In the past decade, Electronic Nose instrumentation has generated much interest internationally for its potential to solve a wide variety of problems in fragrance and cosmetics production, food and beverages manufacturing, chemical engineering, environmental monitoring and more recently medical diagnostic, bioprocesses and clinical diagnostic plant diseases. This instrument measure electrical resistance changes generated by adsorption of volatiles to the surface of electro active- polymer coa...

  12. The multiple applications of electrons in space

    Science.gov (United States)

    Grard, R. J. L.

    1977-01-01

    An electron source such as a simple cathode is a cheap and light device which can serve several technological and scientific purposes in space: (1) electrostatic charging of a spacecraft can be limited by releasing electrons accumulated on the conductive elements of their surface; (2) the erosion of conductive coatings and the ability of conductive paints to withstand the space environment can be evaluated by monitoring the flow of charged particles impinging on their surface; (3) measuring the current collected by the spacecraft surface as a function of its potential with respect to an emitter is a very sensitive diagnostic technique which can yield a number of plasma parameters, such as density and temperature; (4) it is possible to convert the thermal motion of space plasmas into electrical energy by collecting energetic electrons and returning them to the medium as cold particles; (5) a wave in a plasma is characterized by a conduction current density which gives rise to fluctuations of the current flowing to the surface.

  13. Potential applications of electron emission membranes in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Bilevych, Yevgen [Fraunhofer Institute for Reliability and Microintegration (IZM), Berlin (Germany); University of Bonn, Bonn (Germany); Brunner, Stefan E. [Delft University of Technology, Delft (Netherlands); Stefan Meyer Institute for Subatomic Physics, Austrian Academy of Sciences, Vienna (Austria); Chan, Hong Wah; Charbon, Edoardo [Delft University of Technology, Delft (Netherlands); Graaf, Harry van der, E-mail: vdgraaf@nikhef.nl [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); Hagen, Cornelis W. [Delft University of Technology, Delft (Netherlands); Nützel, Gert; Pinto, Serge D. [Photonis, Roden (Netherlands); Prodanović, Violeta [Delft University of Technology, Delft (Netherlands); Rotman, Daan [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands); University of Amsterdam, Amsterdam (Netherlands); Santagata, Fabio [State Key Lab for Solid State Lighti Changzhou base, F7 R& D HUB 1, Science and Education Town, Changzhou 213161, Jangsu Province (China); Sarro, Lina; Schaart, Dennis R. [Delft University of Technology, Delft (Netherlands); Sinsheimer, John; Smedley, John [Brookhaven National Laboratory, Upton, NY (United States); Tao, Shuxia; Theulings, Anne M.M.G. [Delft University of Technology, Delft (Netherlands); Nikhef, Science Park 105, 1098 XG Amsterdam (Netherlands)

    2016-02-11

    With a miniaturised stack of transmission dynodes, a noise free amplifier is being developed for the detection of single free electrons, with excellent time- and 2D spatial resolution and efficiency. With this generic technology, a new family of detectors for individual elementary particles may become possible. Potential applications of such electron emission membranes in medicine are discussed.

  14. Optical Thermal Characterization Enables High-Performance Electronics Applications

    Energy Technology Data Exchange (ETDEWEB)

    2016-02-01

    NREL developed a modeling and experimental strategy to characterize thermal performance of materials. The technique provides critical data on thermal properties with relevance for electronics packaging applications. Thermal contact resistance and bulk thermal conductivity were characterized for new high-performance materials such as thermoplastics, boron-nitride nanosheets, copper nanowires, and atomically bonded layers. The technique is an important tool for developing designs and materials that enable power electronics packaging with small footprint, high power density, and low cost for numerous applications.

  15. Handbook of power systems engineering with power electronics applications

    CERN Document Server

    Hase, Yoshihide

    2012-01-01

    Formerly known as Handbook of Power System Engineering, this second edition provides rigorous revisions to the original treatment of systems analysis together with a substantial new four-chapter section on power electronics applications. Encompassing a whole range of equipment, phenomena, and analytical approaches, this handbook offers a complete overview of power systems and their power electronics applications, and presents a thorough examination of the fundamental principles, combining theories and technologies that are usually treated in separate specialised fields, in a single u

  16. Electronic excitation of furfural as probed by high-resolution vacuum ultraviolet spectroscopy, electron energy loss spectroscopy, and ab initio calculations

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira da Silva, F.; Lange, E. [Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Limão-Vieira, P., E-mail: plimaovieira@fct.unl.pt, E-mail: michael.brunger@flinders.edu.au, E-mail: maplima@ifi.unicamp.br [Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001 (Australia); Jones, N. C.; Hoffmann, S. V. [ISA, Department of Physics and Astronomy, Aarhus University, Ny Munkegade, DK-8000 Århus C (Denmark); Hubin-Franskin, M.-J.; Delwiche, J. [Départment de Chimie, Institut de Chimie-Bât. B6C, Université de Liège, B-4000 Liège 1 (Belgium); Brunger, M. J., E-mail: plimaovieira@fct.unl.pt, E-mail: michael.brunger@flinders.edu.au, E-mail: maplima@ifi.unicamp.br [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001 (Australia); Institute of Mathematical Sciences, University of Malaya, 50603 Kuala Lumpur (Malaysia); and others

    2015-10-14

    The electronic spectroscopy of isolated furfural (2-furaldehyde) in the gas phase has been investigated using high-resolution photoabsorption spectroscopy in the 3.5–10.8 eV energy-range, with absolute cross section measurements derived. Electron energy loss spectra are also measured over a range of kinematical conditions. Those energy loss spectra are used to derive differential cross sections and in turn generalised oscillator strengths. These experiments are supported by ab initio calculations in order to assign the excited states of the neutral molecule. The good agreement between the theoretical results and the measurements allows us to provide the first quantitative assignment of the electronic state spectroscopy of furfural over an extended energy range.

  17. Vacuum fiber-fiber coupler

    Science.gov (United States)

    Heinrici, Axel; Bjelajac, Goran; Jonkers, Jeroen; Jakobs, Stefan; Olschok, Simon; Reisgen, Uwe

    2017-02-01

    Research and development carried out by the ISF Welding and Joining Institute of RWTH Aachen University has proven that combining high power laser and low vacuum atmosphere provides a welding performance and quality, which is comparable to electron beam welding. The developed welding machines are still using a beam forming which takes place outside the vacuum and the focusing laser beam has to be introduced to the vacuum via a suitable window. This inflexible design spoils much of the flexibility of modern laser welding. With the target to bring a compact, lightweight flying optics with flexible laser transport fibers into vacuum chambers, a high power fiber-fiber coupler has been adapted by II-VI HIGHYAG that includes a reliable vacuum interface. The vacuum-fiber-fiber coupler (V-FFC) is tested with up to 16 kW sustained laser power and the design is flexible in terms of a wide variety of laser fiber plug systems and vacuum flanges. All that is needed to implement the V-FFC towards an existing or planned vacuum chamber is an aperture of at least 100 mm (4 inch) diameter with any type of vacuum or pressure flange. The V-FFC has a state-of-the-art safety interface which allows for fast fiber breakage detection for both fibers (as supported by fibers) by electric wire breakage and short circuit detection. Moreover, the System also provides connectors for cooling and electric signals for the laser beam optics inside the vacuum. The V-FFC has all necessary adjustment options for coupling the laser radiation to the receiving fiber.

  18. Cellulose-gold nanowire (GNW) composite for electronic applications

    Science.gov (United States)

    Kim, Joo-Hyung; Lim, Byungwook; Park, Seongsoon

    2012-04-01

    In recent years, regenerated cellulose has received much attention due to its huge industrial potentials and its feasibility for many industrial applications such as sensors and actuators. However, due to its insulating property, few results used for potential electronic applications have been reported. By modification of cellulose itself, nano-sized electrical inner paths can be formed by chemical bonding of metallic or semiconducting nanowires to cellulose fibrils during regenerated process. Already our earlier result of the chemical bonding between carbon nanotubes and the regenerated cellulose has been reported as a novel electronic material for potential paper transistor. In this paper, we study the cellulose-gold nanowire (GNW) composite for electronic application due to its huge potential for paper transistor and other applications such as biosensors and strain sensors due to its electrical response sensitivity. The detailed material properties of GNW cellulose composite and its potential for electrical applications will be demonstrated.

  19. The LHC Vacuum Pilot Sectors Project

    CERN Document Server

    Henrist, B; Bregliozzi, G; Chiggiato, P

    2014-01-01

    The operation of the CERN Large Hadron Collider (LHC) at nominal beam parameters is expected for the next years. Increased synchrotron-radiation stimulated-desorption and electron-cloud build-up are expected. A deep understanding of the interactions between the proton beams and the beam pipe wall is mandatory to control the anticipated beam-induced pressure rise. A Vacuum Pilot Sector (VPS) has been designed to monitor the performance of the vacuum system with time. The VPS is installed along a double LHC room temperature vacuum sector (18 m long, 80 mm inner diameter beam pipes) and includes 8 standard modules, 1.4 m long each. Such modules are equipped with residual gas analysers, Bayard-Alpert gauges, photon and electron flux monitors etc. The chosen modular approach opens the possibility of studying different configurations and implementing future modifications. This contribution will describe the apparatus, the control system designed to drive measurements and possible applications during the LHC Run 2.

  20. Semiconductor nanowires and templates for electronic applications

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Xiang

    2009-07-15

    This thesis starts by developing a platform for the organized growth of nanowires directly on a planar substrate. For this, a method to fabricate horizontal porous alumina membranes is studied. The second part of the thesis focuses on the study of nanowires. It starts by the understanding of the growth mechanisms of germanium nanowires and follows by the structural and electrical properties at the single nanowire level. Horizontally aligned porous anodic alumina (PAA) was used as a template for the nanowire synthesis. Three PAA arrangements were studied: - high density membranes - micron-sized fingers - multi-contacts Membranes formed by a high density of nanopores were obtained by anodizing aluminum thin films. Metallic and semiconducting nanowires were synthesized into the PAA structures via DC deposition, pulsed electro-depostion and CVD growth. The presence of gold, copper, indium, nickel, tellurium, and silicon nanowires inside PAA templates was verified by SEM and EDX analysis. Further, room-temperature transport measurements showed that the pores are completely filled till the bottom of the pores. In this dissertation, single crystalline and core-shell germanium nanowires are synthesized using indium and bismuth as catalyst in a chemical vapor deposition procedure with germane (GeH{sub 4}) as growth precursor. A systematic growth study has been performed to obtain high aspect-ratio germanium nanowires. The influence of the growth conditions on the final morphology and the crystalline structure has been determined via scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM). In the case of indium catalyzed germanium nanowires, two different structures were identified: single crystalline and crystalline core-amorphous shell. The preferential growth axis of both kinds of nanowires is along the [110] direction. The occurrence of the two morphologies was found to only depend on the nanowire dimension. In the case of bismuth

  1. MRI-guided breast vacuum biopsy: Localization of the lesion without contrast-agent application using diffusion-weighted imaging.

    Science.gov (United States)

    Berger, Nicole; Varga, Zsuzsanna; Frauenfelder, Thomas; Boss, Andreas

    2017-05-01

    In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weighted imaging (DWI) for lesion targeting in vacuum assisted magnetic resonance imaging (MRI) biopsies. DWI may be used as an alternative to dynamic contrast-enhanced MRI with the advantage of reproducibility. However, the targeted lesion requires the characteristics of a mass-like lesion, substantial diffusion restriction, and a minimum size of approximately 1cm. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Channel electron multiplier operated on a sounding rocket without a cryogenic vacuum pump from 120 - 75 km altitude

    Science.gov (United States)

    Dickson, S.; Gausa, M. A.; Robertson, S. H.; Sternovsky, Z.

    2012-12-01

    We demonstrate that a channel electron multiplier (CEM) can be operated on a sounding rocket in the pulse-counting mode from 120 km to 75 km altitude without the cryogenic evacuation used in the past. Evacuation of the CEM is provided only by aerodynamic flow around the rocket. This demonstration is motivated by the need for additional flights of mass spectrometers to clarify the fate of metallic compounds and ions ablated from micrometeorites and their possible role in the nucleation of noctilucent clouds. The CEMs were flown as guest instruments on the two sounding rockets of the CHAMPS (CHarge And mass of Meteoritic smoke ParticleS) rocket campaign which were launched into the mesosphere in October 2011 from Andøya Rocket Range, Norway. Modeling of the aerodynamic flow around the payload with Direct Simulation Monte-Carlo (DSMC) code showed that the pressure is reduced below ambient in the void beneath an aft-facing surface. An enclosure containing the CEM was placed above an aft-facing deck and a valve was opened on the downleg to expose the CEM to the aerodynamically evacuated region below. The CEM operated successfully from apogee down to ~75 km. A Pirani gauge confirmed pressures reduced to as low as 20% of ambient with the extent of reduction dependent upon altitude and velocity. Additional DSMC simulations indicate that there are alternate payload designs with improved aerodynamic pumping for forward mounted instruments such as mass spectrometers.

  3. Channel electron multiplier operated on a sounding rocket without a cryogenic vacuum pump from 120 to 80 km altitude

    Science.gov (United States)

    Dickson, Shannon; Gausa, Michael; Robertson, Scott; Sternovsky, Zoltan

    2013-04-01

    We demonstrate that a channel electron multiplier (CEM) can be operated on a sounding rocket in the pulse-counting mode from 120 km to 80 km altitude without the cryogenic evacuation used in the past. Evacuation of the CEM is provided only by aerodynamic flow around the rocket. This demonstration is motivated by the need for additional flights of mass spectrometers to clarify the fate of metallic compounds and ions ablated from micrometeorites and their possible role in the nucleation of noctilucent clouds. The CEMs were flown as guest instruments on two sounding rockets to the mesosphere. Modeling of the aerodynamic flow around the payload with Direct Simulation Monte-Carlo (DSMC) code showed that the pressure is reduced below ambient in the void behind (relative to the direction of motion) an aft-facing surface. An enclosure containing the CEM was placed forward of an aft-facing deck and a valve was opened during flight to expose the CEM to the aerodynamically evacuated region behind it. The CEM operated successfully from apogee down to ∼80 km. A Pirani gauge confirmed pressures reduced to as low as 20% of ambient with the extent of reduction dependent upon altitude and velocity. Additional DSMC simulations indicate that there are alternate payload designs with improved aerodynamic pumping for forward mounted instruments such as mass spectrometers.

  4. Power electronics basics operating principles, design, formulas, and applications

    CERN Document Server

    Rozanov, Yuriy; Chaplygin, Evgeny; Voronin, Pavel

    2015-01-01

    Power Electronics Basics: Operating Principles, Design, Formulas, and Applications provides fundamental knowledge for the analysis and design of modern power electronic devices. This concise and user-friendly resource:Explains the basic concepts and most important terms of power electronicsDescribes the power assemblies, control, and passive components of semiconductor power switchesCovers the control of power electronic devices, from mathematical modeling to the analysis of the electrical processesAddresses pulse-width modulation, power quality control, and multilevel, modular, and multicell

  5. Theory and applications of free-electron vortex states

    Science.gov (United States)

    Bliokh, K. Y.; Ivanov, I. P.; Guzzinati, G.; Clark, L.; Van Boxem, R.; Béché, A.; Juchtmans, R.; Alonso, M. A.; Schattschneider, P.; Nori, F.; Verbeeck, J.

    2017-05-01

    Both classical and quantum waves can form vortices : entities with helical phase fronts and circulating current densities. These features determine the intrinsic orbital angular momentum carried by localized vortex states. In the past 25 years, optical vortex beams have become an inherent part of modern optics, with many remarkable achievements and applications. In the past decade, it has been realized and demonstrated that such vortex beams or wavepackets can also appear in free electron waves, in particular, in electron microscopy. Interest in free-electron vortex states quickly spread over different areas of physics: from basic aspects of quantum mechanics, via applications for fine probing of matter (including individual atoms), to high-energy particle collision and radiation processes. Here we provide a comprehensive review of theoretical and experimental studies in this emerging field of research. We describe the main properties of electron vortex states, experimental achievements and possible applications within transmission electron microscopy, as well as the possible role of vortex electrons in relativistic and high-energy processes. We aim to provide a balanced description including a pedagogical introduction, solid theoretical basis, and a wide range of practical details. Special attention is paid to translating theoretical insights into suggestions for future experiments, in electron microscopy and beyond, in any situation where free electrons occur.

  6. Application of the vacuum-assisted closure in pediatric patients with orthopedic sequelae of meningococcemia: report of a case successfully treated.

    Science.gov (United States)

    Canavese, Federico; Krajbich, Joseph I; Kuang, Anna A

    2009-11-01

    Patients who survive the initial acute phase of fulminant meningococcemia are at an increased risk for serious complications as a result of poor tissue perfusion. It is rare that early surgical intervention is required, as it is relatively difficult to determine the degree of tissue loss early on. Once the patient is stable, debridement of all necrotic tissue is essential and may necessitate extensive removal of skin, subcutaneous tissue, and muscle. Widespread use of the vacuum-assisted closure for complex soft tissue injuries has generally showed accelerated wound healing compared with traditional methods. We report a new possible application of the vacuum-assisted closure system in very young patients with loss of tissue as a result of purpura fulminans secondary to meningococcemia.

  7. HiPTI - High Performance Thermal Insulation, Annex 39 to IEA/ECBCS-Implementing Agreement. Vacuum insulation in the building sector. Systems and applications

    Energy Technology Data Exchange (ETDEWEB)

    Binz, A.; Moosmann, A.; Steinke, G.; Schonhardt, U.; Fregnan, F. [Fachhochschule Nordwestschweiz (FHNW), Muttenz (Switzerland); Simmler, H.; Brunner, S.; Ghazi, K.; Bundi, R. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Heinemann, U.; Schwab, H. [ZAE Bayern, Wuerzburg (Germany); Cauberg, H.; Tenpierik, M. [Delft University of Technology, Delft (Netherlands); Johannesson, G.; Thorsell, T. [Royal Institute of Technology (KTH), Stockholm (Sweden); Erb, M.; Nussbaumer, B. [Dr. Eicher und Pauli AG, Basel and Bern (Switzerland)

    2005-07-01

    This final report on vacuum insulation panels (VIP) presents and discusses the work done under IEA/Energy Conservation in Buildings and Community Systems (ECBCS) Annex 39, subtask B on the basis of a wide selection of reports from practice. The report shows how the building trade deals with this new material today, the experience gained and the conclusions drawn from this work. As well as presenting recommendations for the practical use of VIP, the report also addresses questions regarding the effective insulation values to be expected with current VIP, whose insulation performance is stated as being a factor of five to eight times better than conventional insulation. The introduction of this novel material in the building trade is discussed. Open questions and risks are examined. The fundamentals of vacuum insulation panels are discussed and the prerequisites, risks and optimal application of these materials in the building trade are examined.

  8. High-Power Electron Accelerators for Space (and other) Applications

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lewellen, John W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-23

    This is a presentation on high-power electron accelerators for space and other applications. The main points covered are: electron beams for space applications, new designs of RF accelerators, high-power high-electron mobility transistors (HEMT) testing, and Li-ion battery design. In summary, the authors have considered a concept of 1-MeV electron accelerator that can operate up to several seconds. This concept can be extended to higher energy to produce higher beam power. Going to higher beam energy requires adding more cavities and solid-state HEMT RF power devices. The commercial HEMT have been tested for frequency response and RF output power (up to 420 W). Finally, the authors are testing these HEMT into a resonant load and planning for an electron beam test in FY17.

  9. 2015 Applications in Electronics Pervading Industry, Environment and Society Conference

    CERN Document Server

    2017-01-01

    This book provides a thorough overview of cutting-edge research on electronics applications relevant to industry, the environment, and society at large. It covers a broad spectrum of application domains, from automotive to space and from health to security, while devoting special attention to the use of embedded devices and sensors for imaging, communication and control. The book is based on the 2015 ApplePies Conference, held in Rome, which brought together researchers and stakeholders to consider the most significant current trends in the field of applied electronics and to debate visions for the future. Areas addressed by the conference included information communication technology; biotechnology and biomedical imaging; space; secure, clean and efficient energy; the environment; and smart, green and integrated transport. As electronics technology continues to develop apace, constantly meeting previously unthinkable targets, further attention needs to be directed toward the electronics applications and the ...

  10. Applications in Electronics Pervading Industry, Environment and Society

    CERN Document Server

    2016-01-01

    This book provides a thorough overview of cutting-edge research on electronics applications relevant to industry, the environment, and society at large. A wide spectrum of application domains are covered, from automotive to space and from health to security, and special attention is devoted to the use of embedded devices and sensors for imaging, communication, and control. The book is based on the 2014 APPLEPIES Conference, held in Rome, which brought together researchers and stakeholders to consider the most significant current trends in the field of applied electronics and to debate visions for the future. Areas covered by the conference included information communication technology; biotechnology and biomedical imaging; space; secure, clean, and efficient energy; the environment; and smart, green, and integrated transport. As electronics technology continues to develop apace, constantly meeting previously unthinkable targets, further attention needs to be directed toward the electronics applications and th...

  11. Advances in electronic-nose technologies developed for biomedical applications

    Science.gov (United States)

    Dan Wilson; Manuela. Baietto

    2011-01-01

    The research and development of new electronic-nose applications in the biomedical field has accelerated at a phenomenal rate over the past 25 years. Many innovative e-nose technologies have provided solutions and applications to a wide variety of complex biomedical and healthcare problems. The purposes of this review are to present a comprehensive analysis of past and...

  12. Multifrequency Electron Paramagnetic Resonance Theory and Applications

    CERN Document Server

    Misra, Sushil K

    2011-01-01

    Filling the gap for a systematic, authoritative, and up-to-date review of this cutting-edge technique, this book covers both low and high frequency EPR, emphasizing the importance of adopting the multifrequency approach to study paramagnetic systems in full detail by using the EPR method. In so doing, it discusses not only the underlying theory and applications, but also all recent advances -- with a final section devoted to future perspectives.

  13. Developing a model for application of electronic banking based on electronic trust

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Nazarpoori

    2014-05-01

    Full Text Available This study develops a model for application of electronic banking based on electronic trust among costumers of Day bank in KhoramAbad city. A sample of 150 people was selected based on stratified random sampling. Questionnaires were used for the investigation. Results indicate that technology-based factors, user-based factors, and trust had negative relationships with perceived risk types including financial, functional, personal, and private. Moreover, trust including trust in system and trust in bank had a positive relationship with tendency to use and real application of electronic banking.

  14. Physics of electronic materials principles and applications

    CERN Document Server

    Rammer, Jorgen

    2017-01-01

    Adopting a uniquely pedagogical approach, this comprehensive textbook on the quantum mechanics of semiconductor materials and devices focuses on the materials, components and devices themselves whilst incorporating a substantial amount of fundamental physics related to condensed matter theory and quantum mechanics. Written primarily for advanced undergraduate students in physics and engineering, this book can also be used as a supporting text for introductory quantum mechanics courses, and will be of interest to anyone interested in how electronic devices function at a fundamental level. Complete with numerous exercises, and with all the necessary mathematics and physics included in appendices, this book guides the reader seamlessly through the principles of quantum mechanics and the quantum theory of metals and semiconductors, before describing in detail how devices are exploited within electric circuits and in the hardware of computers, for example as amplifiers, switches and transistors. Includes nume...

  15. Applications of electronic noses in meat analysis

    Directory of Open Access Journals (Sweden)

    Elżbieta GÓRSKA-HORCZYCZAK

    2016-01-01

    Full Text Available Abstract Electronic noses are devices able to characterize and differentiate the aroma profiles of various food, especially meat and meat products. During recent years e-noses have been widely used in food analysis and proved to provide a fast, simple, non-expensive and non-destructive method of food assessment and quality control. The aim of this study is to summarize the most important features of this analytic tool and to present basic fields and typical areas of e-nose use as well as most commonly used sensor types and patterns for e-nose design. Prospects for the future development of this technique are presented. Methods and research results presented in this manuscript may be a guideline for practical e-nose use.

  16. Power electronics for renewable energy systems, transportation and industrial applications

    CERN Document Server

    Malinowski, Mariusz; Al-Haddad, Kamal

    2014-01-01

    Power Electronics for Renewable Energy, Transportation, and Industrial Applications combines state-of-the-art global expertise to present the latest research on power electronics and its application in transportation, renewable energy, and different industrial applications. This timely book aims to facilitate the implementation of cutting-edge techniques to design problems offering innovative solutions to the growing power demands in small- and large-size industries. Application areas in the book range from smart homes and electric and plug-in hybrid electrical vehicles (PHEVs), to smart distribution and intelligence operation centers where significant energy efficiency improvements can be achieved through the appropriate use and design of power electronics and energy storage devices.

  17. Electronic excitation of carbonyl sulphide (COS) by high-resolution vacuum ultraviolet photoabsorption and electron-impact spectroscopy in the energy region from 4 to 11 eV

    Energy Technology Data Exchange (ETDEWEB)

    Limão-Vieira, P., E-mail: plimaovieira@fct.unl.pt [Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Department of Physics, Sophia University, Tokyo 102-8554 (Japan); Department of Physical Sciences, The Open University, Walton Hall, Milton Keynes MK7 6AA (United Kingdom); Ferreira da Silva, F.; Almeida, D. [Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Hoshino, M.; Tanaka, H. [Department of Physics, Sophia University, Tokyo 102-8554 (Japan); Mogi, D. [Development and Marketing Department, New Products Development Division, Kanto Denka, Kogyo Co., Ltd., Chiyoda-ku, Tokyo 101-0063 (Japan); Tanioka, T. [Shibukawa Development Research Laboratory, New Products Development Division, Kanto Denka Kogyo Co., Ltd., Shibukawa City, Gunma 377-8513 (Japan); Mason, N. J. [Department of Physical Sciences, The Open University, Walton Hall, Milton Keynes MK7 6AA (United Kingdom); Hoffmann, S. V. [ISA, Department of Physics and Astronomy, Aarhus University, Ny Munkegade 120, DK-8000 Århus C (Denmark); Hubin-Franskin, M.-J.; Delwiche, J. [Départment de Chimie, Université de Liège, Institut de Chimie-Bât. B6C, allée de la Chimie 3, B-4000 Liège 1 (Belgium)

    2015-02-14

    The electronic state spectroscopy of carbonyl sulphide, COS, has been investigated using high resolution vacuum ultraviolet photoabsorption spectroscopy and electron energy loss spectroscopy in the energy range of 4.0–10.8 eV. The spectrum reveals several new features not previously reported in the literature. Vibronic structure has been observed, notably in the low energy absorption dipole forbidden band assigned to the (4π←3π) ({sup 1}Δ←{sup 1}Σ{sup +}) transition, with a new weak transition assigned to ({sup 1}Σ{sup −}←{sup 1}Σ{sup +}) reported here for the first time. The absolute optical oscillator strengths are determined for ground state to {sup 1}Σ{sup +} and {sup 1}Π transitions. Based on our recent measurements of differential cross sections for the optically allowed ({sup 1}Σ{sup +} and {sup 1}Π) transitions of COS by electron impact, the optical oscillator strength f{sub 0} value and integral cross sections (ICSs) are derived by applying a generalized oscillator strength analysis. Subsequently, ICSs predicted by the scaling are confirmed down to 60 eV in the intermediate energy region. The measured absolute photoabsorption cross sections have been used to calculate the photolysis lifetime of carbonyl sulphide in the upper stratosphere (20–50 km)

  18. Pinched propagation of high-power, pulsed electron beams for welding and materials processing applications

    Science.gov (United States)

    Fernsler, Richard F.; Hubbard, Richard F.; Lampe, Martin

    1994-01-01

    Electron beams are used commercially as intense heating sources for welding and related materials processing applications. The beams used for welding operate continuously with energy up to 200 keV and current approximately 1 A. Because these beams are severely degraded by propagation in air over any substantial range, most present-day electron-beam welders require vacuum pumping and precision focusing, which has severely restricted utilization of the technology. Over the past few decades, a different class of electron-beam generators has been developed that produces pulsed beams with energies of several MeV, currents of 1 kA or more, radii as small as 1 mm, pulse lengths of tens of ns, and pulse repetition rates up to several kHz. We show here that beams of this type can propagate in ambient air, in a tightly pinched mode and with acceptable stability, over distances of a few tens of cm. We determine the constraints on the choice of beam parameters, due mainly to the effects of gas scattering and the resistive instability. We show that stability can be enhanced, and the acceptable parameter range extended considerably, by using a narrow conducting pipe filled with air or another gas to guide the beam to the workpiece.

  19. On the application of quantum transport theory to electron sources.

    Science.gov (United States)

    Jensen, Kevin L

    2003-01-01

    Electron sources (e.g., field emitter arrays, wide band-gap (WBG) semiconductor materials and coatings, carbon nanotubes, etc.) seek to exploit ballistic transport within the vacuum after emission from microfabricated structures. Regardless of kind, all sources strive to minimize the barrier to electron emission by engineering material properties (work function/electron affinity) or physical geometry (field enhancement) of the cathode. The unique capabilities of cold cathodes, such as instant ON/OFF performance, high brightness, high current density, large transconductance to capacitance ratio, cold emission, small size and/or low voltage operation characteristics, commend their use in several advanced devices when physical size, weight, power consumption, beam current, and pulse repletion frequency are important, e.g., RF power amplifier such as traveling wave tubes (TWTs) for radar and communications, electrodynamic tethers for satellite deboost/reboost, and electric propulsion systems such as Hall thrusters for small satellites. The theoretical program described herein is directed towards models to evaluate emission current from electron sources (in particular, emission from WBG and Spindt-type field emitter) in order to assess their utility, capabilities and performance characteristics. Modeling efforts particularly include: band bending, non-linear and resonant (Poole-Frenkel) potentials, the extension of one-dimensional theory to multi-dimensional structures, and emission site statistics due to variations in geometry and the presence of adsorbates. Two particular methodologies, namely, the modified Airy approach and metal-semiconductor statistical hyperbolic/ellipsoidal model, are described in detail in their present stage of development.

  20. Toward Environmentally Robust Organic Electronics: Approaches and Applications.

    Science.gov (United States)

    Lee, Eun Kwang; Lee, Moo Yeol; Park, Cheol Hee; Lee, Hae Rang; Oh, Joon Hak

    2017-11-01

    Recent interest in flexible electronics has led to a paradigm shift in consumer electronics, and the emergent development of stretchable and wearable electronics is opening a new spectrum of ubiquitous applications for electronics. Organic electronic materials, such as π-conjugated small molecules and polymers, are highly suitable for use in low-cost wearable electronic devices, and their charge-carrier mobilities have now exceeded that of amorphous silicon. However, their commercialization is minimal, mainly because of weaknesses in terms of operational stability, long-term stability under ambient conditions, and chemical stability related to fabrication processes. Recently, however, many attempts have been made to overcome such instabilities of organic electronic materials. Here, an overview is provided of the strategies developed for environmentally robust organic electronics to overcome the detrimental effects of various critical factors such as oxygen, water, chemicals, heat, and light. Additionally, molecular design approaches to π-conjugated small molecules and polymers that are highly stable under ambient and harsh conditions are explored; such materials will circumvent the need for encapsulation and provide a greater degree of freedom using simple solution-based device-fabrication techniques. Applications that are made possible through these strategies are highlighted. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Liquid phase exfoliated graphene for electronic applications

    Science.gov (United States)

    Sukumaran, Sheena S.; Jinesh, K. B.; Gopchandran, K. G.

    2017-09-01

    Graphene dispersions were prepared using the liquid phase exfoliation method with three different surfactants. One surfactant was used from each of the surfactant types, anionic, cationic, and non-ionic; those used, were sodium dodecylbenzene sulfonate (SDBS), cetyltrimethylammonium bromide (CTAB) and polyvinylpyrrolidone (PVP), respectively. Raman spectroscopy was used to investigate the number of layers and the nature of any defects present in the exfoliated graphene. The yield of graphene was found to be less with the non-ionic surfactant, PVP. The deconvolution of 2D peaks at ~2700 cm-1 indicated that graphene prepared using these surfactants resulted in sheets consisting of few-layer graphene. The ratio of intensity of the D and G bands in the Raman spectra showed that edge defect density is high for samples prepared with SDBS compared to the other two, and is attributed to the smaller size of the graphene sheets, as shown in the electron micrographs. In the case of the dispersion in PVP, it is found that the sizes of the graphene sheets are highly sensitive to the concentration of the surfactant used. Here, we have made an attempt to investigate the local density of states in the graphene sheets by measuring the tunnelling current-voltage characteristics. Graphene layers have shown consistent p-type behaviour when exfoliated with SDBS and n-type behaviour when exfoliated with CTAB, with a larger band gap for graphene exfoliated using CTAB. Hence, in addition to the known advantages of liquid phase exfoliation, we found that by selecting suitable surfactants, to a certain extent it is possible to tune the band gap and determine the type of majority carriers.

  2. Molecular modeling and multiscaling issues for electronic material applications

    CERN Document Server

    Iwamoto, Nancy; Yuen, Matthew; Fan, Haibo

    Volume 1 : Molecular Modeling and Multiscaling Issues for Electronic Material Applications provides a snapshot on the progression of molecular modeling in the electronics industry and how molecular modeling is currently being used to understand material performance to solve relevant issues in this field. This book is intended to introduce the reader to the evolving role of molecular modeling, especially seen through the eyes of the IEEE community involved in material modeling for electronic applications.  Part I presents  the role that quantum mechanics can play in performance prediction, such as properties dependent upon electronic structure, but also shows examples how molecular models may be used in performance diagnostics, especially when chemistry is part of the performance issue.  Part II gives examples of large-scale atomistic methods in material failure and shows several examples of transitioning between grain boundary simulations (on the atomistic level)and large-scale models including an example ...

  3. Electron beam irradiation processing for industrial and medical applications

    Science.gov (United States)

    Ozer, Zehra Nur

    2017-09-01

    In recent years, electron beam processing has been widely used for medical and industrial applications. Electron beam accelerators are reliable and durable equipments that can produce ionizing radiation when it is needed for a particular commercial use. On the industrial scale, accelerators are used to generate electrons in between 0.1-100 MeV energy range. These accelerators are used mainly in plastics, automotive, wire and electric cables, semiconductors, health care, aerospace and environmental industries, as well as numerous researches. This study presents the current applications of electron beam processing in medicine and industry. Also planned study of a design for such a system in the energy range of 200-300 keV is introduced.

  4. Silicon nanocrystal films for electronic applications

    Energy Technology Data Exchange (ETDEWEB)

    Lechner, Robert W.

    2009-02-06

    Whether nanoparticles of silicon are really suited for such applications, whether layers fabricated from this exhibit semiconducting properties, whether they can be doped, and whether for instance via the doping the conductivity can be tuned, was studied in the present thesis. Starting material for this were on the one hand spherical silicon nanocrystals with a sharp size distribution and mean diameters in the range from 4-50 nm. Furthermore silicon particle were available, which are with 50-500 nm distinctly larger and exhibit a broad distribution of the mean size and a polycrystalline fine structure with strongly bifurcated external morphology. The small conductivities and tje low mobility values of the charge carriers in the layers of silicon nanocrystals suggest to apply suited thermal after-treatment procedures. So was found that the aluminium-induced layer exchange (ALILE) also can be transferred to the porous layers of nanocrystals. With the deuteron passivation a method was available to change the charge-carrier concentration in the polycrystalline layers. Additionally to ALILE laser crystallization as alternative after-treatment procedure of the nanocrystal layers was studied.

  5. Industrial applications of electron beam; Przemyslowe zastosowamia wiazki elektronow

    Energy Technology Data Exchange (ETDEWEB)

    Chmielewski, A.G. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    The review of industrial applications with use of electron beams has been done. Especially the radiation technologies being developed in Poland have been shown. Industrial installations with electron accelerators as radiation source have been applied for: modification of polymers; modification of thyristors; sterilization of health care materials; radiopreservation of food and other consumer products; purification of combustion flue gases in heat and power plants. 14 refs, 6 tabs, 7 figs.

  6. Applications of orientation mapping by scanning and transmission electron microscopy

    DEFF Research Database (Denmark)

    Juul Jensen, D.

    1997-01-01

    The potentials of orientation mapping techniques (in the following referred to as OIM) for studies of thermomechanical processes are analysed. Both transmission electron microscopy (TEM) and scanning electron microscopy (SEM) based OIM techniques are considered. Among the thermomechanical processes...... information is achieved when the results of OIM and these various techniques are combined. Examples hereof are given to illustrate the potentials of OIM techniques. Finally, limitations of TEM and SEM based OIM for specific applications are discussed....

  7. Applicability of Vacuum Impregnation to Modify Physico-Chemical, Sensory and Nutritive Characteristics of Plant Origin Products—A Review

    Science.gov (United States)

    Radziejewska-Kubzdela, Elżbieta; Biegańska-Marecik, Róża; Kidoń, Marcin

    2014-01-01

    Vacuum impregnation is a non-destructive method of introducing a solution with a specific composition to the porous matrices of fruit and vegetables. Mass transfer in this process is a result of mechanically induced differences in pressure. Vacuum impregnation makes it possible to fill large volumes of intercellular spaces in tissues of fruit and vegetables, thus modifying physico-chemical properties and sensory attributes of products. This method may be used, e.g., to reduce pH and water activity of the product, change its thermal properties, improve texture, color, taste and aroma. Additionally, bioactive compounds may be introduced together with impregnating solutions, thus improving health-promoting properties of the product or facilitating production of functional food. PMID:25244012

  8. Adhesives technology for electronic applications materials, processing, reliability

    CERN Document Server

    Licari, James J

    2011-01-01

    Adhesives are widely used in the manufacture and assembly of electronic circuits and products. Generally, electronics design engineers and manufacturing engineers are not well versed in adhesives, while adhesion chemists have a limited knowledge of electronics. This book bridges these knowledge gaps and is useful to both groups. The book includes chapters covering types of adhesive, the chemistry on which they are based, and their properties, applications, processes, specifications, and reliability. Coverage of toxicity, environmental impacts and the regulatory framework make this book par

  9. Handbook of polymer coatings for electronics chemistry, technology and applications

    CERN Document Server

    Licari, James J

    1990-01-01

    This completely revised edition remains the only comprehensive treatise on polymer coatings for electronics. Since the original edition, the applications of coatings for the environmental protection of electronic systems have greatly increased, largely driven by the competitive need to reduce costs, weight and volume. The demands for high-speed circuits for the rapid processing of signals and data, high-density circuits for the storage and retrieval of megabits of memory, and the improved reliability required of electronics for guiding and controlling weapons and space vehicles have triggered

  10. Electronically Tunable Multi-Terminal Floating Nullor and Its Applications

    Directory of Open Access Journals (Sweden)

    W. Tangsrirat

    2008-12-01

    Full Text Available A realization scheme of an electronically tun- able multi-terminal floating nullor (ET-MTFN is de- scribed in this paper. The proposed circuit mainly employs a transconductance amplifier, an improved translinear cell, two complementary current mirrors with variable current gain and improved Wilson current mirrors, which provide an electronic tuning of the current gain. The va- lidity of the performance of the scheme is verified through PSPICE simulation results. Example applications employing the proposed ET-MTFN as an active element demonstrate that the circuit properties can be varied by electronic means.

  11. Applications and Advances in Electronic-Nose Technologies

    Directory of Open Access Journals (Sweden)

    Manuela Baietto

    2009-06-01

    Full Text Available Electronic-nose devices have received considerable attention in the field of sensor technology during the past twenty years, largely due to the discovery of numerous applications derived from research in diverse fields of applied sciences. Recent applications of electronic nose technologies have come through advances in sensor design, material improvements, software innovations and progress in microcircuitry design and systems integration. The invention of many new e-nose sensor types and arrays, based on different detection principles and mechanisms, is closely correlated with the expansion of new applications. Electronic noses have provided a plethora of benefits to a variety of commercial industries, including the agricultural, biomedical, cosmetics, environmental, food, manufacturing, military, pharmaceutical, regulatory, and various scientific research fields. Advances have improved product attributes, uniformity, and consistency as a result of increases in quality control capabilities afforded by electronic-nose monitoring of all phases of industrial manufacturing processes. This paper is a review of the major electronic-nose technologies, developed since this specialized field was born and became prominent in the mid 1980s, and a summarization of some of the more important and useful applications that have been of greatest benefit to man.

  12. Vacuum phenomenon.

    Science.gov (United States)

    Yanagawa, Youichi; Ohsaka, Hiromichi; Jitsuiki, Kei; Yoshizawa, Toshihiko; Takeuchi, Ikuto; Omori, Kazuhiko; Oode, Yasumasa; Ishikawa, Kouhei

    2016-08-01

    This article describes the theory of the formation of the vacuum phenomenon (VP), the detection of the VP, the different medical causes, the different locations of the presentation of the VP, and the differential diagnoses. In the human body, the cavitation effect is recognized on radiological studies; it is called the VP. The mechanism responsible for the formation of the VP is as follows: if an enclosed tissue space is allowed to expand as a rebound phenomenon after an external impact, the volume within the enclosed space will increase. In the setting of expanding volume, the pressure within the space will decrease. The solubility of the gas in the enclosed space will decrease as the pressure of the space decreases. Decreased solubility allows a gas to leave a solution. Clinically, the pathologies associated with the VP have been reported to mainly include the normal joint motion, degeneration of the intervertebral discs or joints, and trauma. The frequent use of CT for trauma patients and the high spatial resolution of CT images might produce the greatest number of chances to detect the VP in trauma patients. The VP is observed at locations that experience a traumatic impact; thus, an analysis of the VP may be useful for elucidating the mechanism of an injury. When the VP is located in the abdomen, it is important to include perforation of the digestive tract in the differential diagnosis. The presence of the VP in trauma patients does not itself influence the final outcome.

  13. Transition metal oxides for organic electronics: energetics, device physics and applications.

    Science.gov (United States)

    Meyer, Jens; Hamwi, Sami; Kröger, Michael; Kowalsky, Wolfgang; Riedl, Thomas; Kahn, Antoine

    2012-10-23

    During the last few years, transition metal oxides (TMO) such as molybdenum tri-oxide (MoO(3) ), vanadium pent-oxide (V(2) O(5) ) or tungsten tri-oxide (WO(3) ) have been extensively studied because of their exceptional electronic properties for charge injection and extraction in organic electronic devices. These unique properties have led to the performance enhancement of several types of devices and to a variety of novel applications. TMOs have been used to realize efficient and long-term stable p-type doping of wide band gap organic materials, charge-generation junctions for stacked organic light emitting diodes (OLED), sputtering buffer layers for semi-transparent devices, and organic photovoltaic (OPV) cells with improved charge extraction, enhanced power conversion efficiency and substantially improved long term stability. Energetics in general play a key role in advancing device structure and performance in organic electronics; however, the literature provides a very inconsistent picture of the electronic structure of TMOs and the resulting interpretation of their role as functional constituents in organic electronics. With this review we intend to clarify some of the existing misconceptions. An overview of TMO-based device architectures ranging from transparent OLEDs to tandem OPV cells is also given. Various TMO film deposition methods are reviewed, addressing vacuum evaporation and recent approaches for solution-based processing. The specific properties of the resulting materials and their role as functional layers in organic devices are discussed. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Application of vacuum metallurgy to separate pure metal from mixed metallic particles of crushed waste printed circuit board scraps.

    Science.gov (United States)

    Zhan, Lu; Xu, Zhenming

    2008-10-15

    The principle of separating pure metal from mixed metallic particles (MMPs) byvacuum metallurgy is that the vapor pressures of various metals at the same temperature are different As a result, the metal with high vapor pressure and low boiling point can be separated from the mixed metals through distillation or sublimation, and then it can be recycled through condensation under a certain condition. The vacuum metallurgy separation (VMS) of MMPs of crushed waste printed circuit boards (WPCBs) has been studied in this paper. Theoretical analyses show that the MMPs (copper, zinc, bismuth, lead, and indium, for example) can be separated by vacuum metallurgy. The copper particles (0.15-0.20 mm) and zinc particles (<0.30 mm) were chosen to simulate the MMPs of crushed WPCBs. Experimental results show that the separated efficiency of zinc in the copper-rich particles achieves 96.19 wt % when the vacuum pressure is 0.01-0.10 Pa, the heating temperature is 1123 K, and the heating time is 105 min. Under this operation condition, the separated efficiency of zinc in the copper-rich particles from crushed WPCBs achieves 97.00 wt % and the copper purity increases from 90.68 to 99.84 wt %.

  15. History and modern applications of nano-composite materials carrying GA/cm2 current density due to a Bose-Einstein Condensate at room temperature produced by Focused Electron Beam Induced Processing for many extraordinary novel technical applications

    Science.gov (United States)

    Koops, Hans W. P.

    2015-12-01

    The discovery of Focused Electron Beam Induced Processing and early applications of this technology led to the possible use of a novel nanogranular material “Koops-GranMat®” using Pt/C and Au/C material. which carries at room temperature a current density > 50 times the current density which high TC superconductors can carry. The explanation for the characteristics of this novel material is given. This fact allows producing novel products for many applications using Dual Beam system having a gas supply and X.Y.T stream data programming and not using GDSII layout pattern control software. Novel products are possible for energy transportation. -distribution.-switching, photon-detection above 65 meV energy for very efficient energy harvesting, for bright field emission electron sources used for vacuum electronic devices like amplifiers for HF electronics, micro-tubes, 30 GHz to 6 THz switching amplifiers with signal to noise ratio >10(!), THz power sources up to 1 Watt, in combination with miniaturized vacuum pumps, vacuum gauges, IR to THz detectors, EUV- and X-Ray sources. Since focusing electron beam induced deposition works also at low energy, selfcloning multibeam-production machines for field emitter lamps, displays, multi-beam - lithography, - imaging, and - inspection, energy harvesting, and power distribution with switches controlling field-emitter arrays for KA of currents but with < 100 V switching voltage are possible. Finally the replacement of HTC superconductors and its applications by the Koops-GranMat® having Koops-Pairs at room temperature will allow the investigation devices similar to Josephson Junctions and its applications now called QUIDART (Quantum interference devices at Room Temperature). All these possibilities will support a revolution in the optical, electric, power, and electronic technology.

  16. Pixel readout electronics for LHC and biomedical applications

    CERN Document Server

    Blanquart, L; Comes, G; Delpierre, P A; Fischer, P; Hausmann, J C; Keil, M; Lindner, Manfred; Meuser, S; Wermes, N

    2000-01-01

    The demanding requirements for pixel readout electronics for high- energy physics experiments and biomedical applications are reviewed. Some examples of the measured analog performance of prototype chips are given. The readout architectures of the PIxel readout for the ATlas experiment (PIRATE) chip suited for LHC experiments and of the multi-picture element counter (MPEC) counting chip targeted for biomedical applications are presented. First results with complete chip-sensor assemblies are also shown. (12 refs).

  17. Generation and application of bessel beams in electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Grillo, Vincenzo, E-mail: vincenzo.grillo@cnr.it [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); CNR-IMEM, Parco Area delle Scienze 37/A, I-43124 Parma (Italy); Harris, Jérémie [Department of Physics, University of Ottawa, 25 Templeton St., Ottawa, Ontario, Canada K1N 6N5 (Canada); Gazzadi, Gian Carlo [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); Balboni, Roberto [CNR-IMM Bologna, Via P. Gobetti 101, 40129 Bologna (Italy); Mafakheri, Erfan [Dipartimento di Fisica Informatica e Matematica, Università di Modena e Reggio Emilia, via G Campi 213/a, I-41125 Modena (Italy); Dennis, Mark R. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom); Frabboni, Stefano [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); Dipartimento di Fisica Informatica e Matematica, Università di Modena e Reggio Emilia, via G Campi 213/a, I-41125 Modena (Italy); Boyd, Robert W.; Karimi, Ebrahim [Department of Physics, University of Ottawa, 25 Templeton St., Ottawa, Ontario, Canada K1N 6N5 (Canada)

    2016-07-15

    We report a systematic treatment of the holographic generation of electron Bessel beams, with a view to applications in electron microscopy. We describe in detail the theory underlying hologram patterning, as well as the actual electron-optical configuration used experimentally. We show that by optimizing our nanofabrication recipe, electron Bessel beams can be generated with relative efficiencies reaching 37±3%. We also demonstrate by tuning various hologram parameters that electron Bessel beams can be produced with many visible rings, making them ideal for interferometric applications, or in more highly localized forms with fewer rings, more suitable for imaging. We describe the settings required to tune beam localization in this way, and explore beam and hologram configurations that allow the convergences and topological charges of electron Bessel beams to be controlled. We also characterize the phase structure of the Bessel beams generated with our technique, using a simulation procedure that accounts for imperfections in the hologram manufacturing process. - Highlights: • Bessel beams with different convergence, topological charge, visible fringes are demonstrated. • The relation between the Fresnel hologram and the probe shape is explained by detailed calculations and experiments. • Among the holograms here presented the highest relative efficiency is 37%, the best result ever reached for blazed holograms.

  18. Application of a grating coupler for surface plasmon polariton excitation in a photoemission electron microscopy experiment

    DEFF Research Database (Denmark)

    Leißner, Till; Jauernik, Stephan; Lemke, Christoph

    Surface plasmon polariton (SPP) excitation at a gold-vacuum interface via 800 nm light pulses mediated by a periodic array of gold ridges is probed at high lateral resolution by means of photoemission electron microscopy (PEEM). We directly monitor and quantify the coupling properties as a function...

  19. 20 CFR 321.1 - Filing applications electronically.

    Science.gov (United States)

    2010-04-01

    ... Section 321.1 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE RAILROAD UNEMPLOYMENT... under the Railroad Unemployment Insurance Act may be filed electronically through the Board's Internet Web site, http://www.rrb.gov, utilizing a User ID and a PIN/Password. (b) Adjudication of applications...

  20. Application of maximum entropy method for the study of electron ...

    Indian Academy of Sciences (India)

    Application of maximum entropy method for the study of electron density distribution in ... the sulphide has been divided into 64 × 64 × 64 pixels), a supercomputing system is needed in most cases involving lower ..... predicting metallurgical behaviour of the elements in binary alloy systems, LA-2345. (Los Alamos Scientific ...

  1. Development and applications of gas electron multiplier detectors

    CERN Document Server

    Sauli, Fabio

    2003-01-01

    An overview of the recent developments in the field of gas electron multiplier (GEM) detectors was presented. Cascading of several GEM foils permits the sustaining of large gains and thereby allows the detection of minimum ionizing particles. The application of GEM included, fast and position sensitive detection in particle physics, medicine, neutron spectrometry, and astrophysics. (Edited abstract) 19 Refs.

  2. Biological applications of phase-contrast electron microscopy.

    Science.gov (United States)

    Nagayama, Kuniaki

    2014-01-01

    Here, I review the principles and applications of phase-contrast electron microscopy using phase plates. First, I develop the principle of phase contrast based on a minimal model of microscopy, introducing a double Fourier-transform process to mathematically formulate the image formation. Next, I explain four phase-contrast (PC) schemes, defocus PC, Zernike PC, Hilbert differential contrast, and schlieren optics, as image-filtering processes in the context of the minimal model, with particular emphases on the Zernike PC and corresponding Zernike phase plates. Finally, I review applications of Zernike PC cryo-electron microscopy to biological systems such as protein molecules, virus particles, and cells, including single-particle analysis to delineate three-dimensional (3D) structures of protein and virus particles and cryo-electron tomography to reconstruct 3D images of complex protein systems and cells.

  3. Carbon nanotube buckypaper reinforced acrylonitrile-butadiene-styrene composites for electronic applications.

    Science.gov (United States)

    Díez-Pascual, Ana M; Gascón, David

    2013-11-27

    Novel acrylonitrile-butadiene-styrene (ABS) nanocomposites reinforced with pristine or functionalized single- or multiwalled carbon nanotube buckypaper (BP) sheets were manufactured via hot-compression and vacuum infiltration. Their morphology, thermal, mechanical, and electrical properties were comparatively investigated. Scanning electron microscopy and thermogravimetric analysis showed that the infiltration process leads to better BP impregnation than the hot-press technique. BPs made from functionalized or short nanotubes form compact networks that hamper the penetration of the matrix chains, whereas those composed of pristine tubes possess large pores that facilitate the polymer flow, resulting in composites with low degree of porosity and improved mechanical performance. Enhanced thermal and electrical properties are found for samples incorporating functionalized BPs since dense networks lead to more conductive pathways, and a stronger barrier effect to the diffusion of degradation products, thus better thermal stability. According to dynamic mechanical analysis these composites exhibit the highest glass transition temperatures, suggesting enhanced filler-matrix interactions as corroborated by the Raman spectra. The results presented herein demonstrate that the composite performance can be tailored by controlling the BP architecture and offer useful insights into the structure-property relationships of these materials to be used in electronic applications, particularly for EMI shielding and packaging of integrated circuits.

  4. Wafer bonding technology for new generation vacuum MEMS: challenges and promises

    Science.gov (United States)

    Dragoi, V.; Pabo, E.

    2015-05-01

    Various MEMS devices are incorporated into consumer electronic devices. A particular category of MEMS require vacuum packaging by wafer bonding with the need to encapsulate vacuum levels of 10-2 mbar or higher with long time stability. The vacuum requirement is limiting the choice of the wafer bonding process and raises significant challenges to the existing investigation methods (metrology) used for results qualification. From the broad range of wafer bonding processes only few are compatible with vacuum applications: fusion bonding, anodic bonding, glass frit bonding and metal-based bonding. The outgassing from the enclosed surfaces after bonding will affect the vacuum level in the cavity: in some cases, a getter material is used inside the device cavity to compensate for this outgassing. Additionally the selected bonding process must be compatible with the devices on the wafers being bonded. This work reviews the principles of vacuum encapsulation using wafer bonding. Examples showing the suitability of each process for specific applications types will be presented. A significant challenge in vacuum MEMS fabrication is the lack of analytical methods needed for process characterization or reliability testing. A short overview of the most used methods and their limitations will be presented. Specific needs to be addressed will be introduced with examples.

  5. Filler-wire positioner for electron beam welding

    Science.gov (United States)

    Beaupre, W. M.; Fueg, L. B.; Phillips, J. A.

    1970-01-01

    Miniaturized positioner is installed in any electron beam vacuum chamber for use with wire feed applications requiring filler wire. Horizontal and vertical control of the positioner is maintained from a console while chamber is under vacuum. Device permits more positive positioning of welding filler wire.

  6. Many-body approach to electronic excitations concepts and applications

    CERN Document Server

    Bechstedt, Friedhelm

    2015-01-01

    The many-body-theoretical basis and applications of theoretical spectroscopy of condensed matter, e.g. crystals, nanosystems, and molecules are unified in one advanced text for readers from graduate students to active researchers in the field. The theory is developed from first principles including fully the electron-electron interaction and spin interactions. It is based on the many-body perturbation theory, a quantum-field-theoretical description, and Green's functions. The important expressions for ground states as well as electronic single-particle and pair excitations are explained. Based on single-particle and two-particle Green's functions, the Dyson and Bethe-Salpeter equations are derived. They are applied to calculate spectral and response functions. Important spectra are those which can be measured using photoemission/inverse photoemission, optical spectroscopy, and electron energy loss/inelastic X-ray spectroscopy. Important approximations are derived and discussed in the light of selected computa...

  7. Measurement of partial pressures in vacuum technology and vacuum physics

    Science.gov (United States)

    Huber, W. K.

    1986-01-01

    It is pointed out that the measurement of gaseous pressures of less than 0.0001 torr is based on the ionization of gas atoms and molecules due to collisions with electrons. The particle density is determined in place of the pressure. The ionization cross sections for molecules of various gases are discussed. It is found that the true pressure in a vacuum system cannot be determined with certainty if it is unknown which gas is present. Effects of partial pressure determination on the condition of the vacuum system are discussed together with ion sources, systems of separation, and ion detection.

  8. High efficiency digital cooler electronics for aerospace applications

    Science.gov (United States)

    Kirkconnell, C. S.; Luong, T. T.; Shaw, L. S.; Murphy, J. B.; Moody, E. A.; Lisiecki, A. L.; Ellis, M. J.

    2014-06-01

    Closed-cycle cryogenic refrigerators, or cryocoolers, are an enabling technology for a wide range of aerospace applications, mostly related to infrared (IR) sensors. While the industry focus has tended to be on the mechanical cryocooler thermo mechanical unit (TMU) alone, implementation on a platform necessarily consists of the combination of the TMU and a mating set of command and control electronics. For some applications the cryocooler electronics (CCE) are technologically simple and low cost relative to the TMU, but this is not always the case. The relative cost and complexity of the CCE for a space-borne application can easily exceed that of the TMU, primarily due to the technical constraints and cost impacts introduced by the typical space radiation hardness and reliability requirements. High end tactical IR sensor applications also challenge the state of the art in cryocooler electronics, such as those for which temperature setpoint and frequency must be adjustable, or those where an informative telemetry set must be supported, etc. Generally speaking for both space and tactical applications, it is often the CCE that limits the rated lifetime and reliability of the cryocooler system. A family of high end digital cryocooler electronics has been developed to address these needs. These electronics are readily scalable from 10W to 500W output capacity; experimental performance data for nominally 25W and 100W variants are presented. The combination of a FPGA-based controller and dual H-bridge motor drive architectures yields high efficiency (>92% typical) and precision temperature control (+/- 30 mK typical) for a wide range of Stirling-class mechanical cryocooler types and vendors. This paper focuses on recent testing with the AIM INFRAROT-MODULE GmbH (AIM) SX030 and AIM SF100 cryocoolers.

  9. Integrated graphene/nanoparticle hybrids for biological and electronic applications.

    Science.gov (United States)

    Nguyen, Kim Truc; Zhao, Yanli

    2014-06-21

    The development of novel graphene/nanoparticle hybrid materials is currently the subject of tremendous research interest. The intrinsic exceptional assets of both graphene (including graphene oxide and reduced graphene oxide) and nanoparticles render their hybrid materials synergic properties that can be useful in various applications. In this feature review, we highlight recent developments in graphene/nanoparticle hybrids and their promising potential in electronic and biological applications. First, the latest advances in synthetic methods for the preparation of the graphene/nanoparticle hybrids are introduced, with the emphasis on approaches to (1) decorate nanoparticles onto two-dimensional graphene and (2) wrap nanoparticles with graphene sheets. The pros and cons of large-scale synthesis are also discussed. Then, the state-of-the-art of graphene/nanoparticle hybrids in electronic and biological applications is reviewed. For electronic applications, we focus on the advantages of using these hybrids in transparent conducting films, as well as energy harvesting and storage. Biological applications, electrochemical biosensing, bioimaging, and drug delivery using the hybrids are showcased. Finally, the future research prospects and challenges in this rapidly developing area are discussed.

  10. Vacuum ultraviolet spectroscopy I

    CERN Document Server

    Samson, James A; Lucatorto, Thomas

    1998-01-01

    This volume is for practitioners, experimentalists, and graduate students in applied physics, particularly in the fields of atomic and molecular physics, who work with vacuum ultraviolet applications and are in need of choosing the best type of modern instrumentation. It provides first-hand knowledge of the state-of-the-art equipment sources and gives technical information on how to use it, along with a broad reference bibliography.Key Features* Aimed at experimentalists who are in need of choosing the best type of modern instrumentation in this applied field* Contains a detailed chapter on la

  11. Application of Vacuum-Assisted Closure Therapy and Hyperbaric Oxygen Therapy for an Exposed Titanium Plate After Mandible Reconstruction.

    Science.gov (United States)

    Maeda, Taku; Yamamoto, Yuhei; Tanaka, Soichi; Hayashi, Toshihiko

    2016-10-01

    The authors report a case of an 84-year-old woman with an exposed mandibular plate after reconstruction, which finally healed with combination therapy using vacuum-assisted closure therapy and hyperbaric oxygen therapy. The woman was diagnosed with mucosal carcinoma of the right oral cavity. During reconstruction after segmental excision of the mandible, a titanium plate was selected based on several risk factors. After the operation, the plate became exposed at the center of the chin. A second surgery was deemed inappropriate because of her age, malnutrition, and recurrent aspiration pneumonia. Instead, combination therapy consisting of vacuum-assisted closure therapy and hyperbaric oxygen therapy was initiated, leading to epithelizaion of the wound. Adapt Barrier Rings was effectively used to generate a stable negative pressure at the complicated craniofacial wound. A surgical or conservative approach is chosen as salvage treatment of an exposed plate. In this patient, only conservative treatment involving combination therapy resulted in complete healing of the wound with plate exposure. This patient highlights 2 important clinical issues: combination therapy was effective for an exposed mandibular plate, and a dressing technique using Adapt Barrier Rings enabled stable negative pressure in the craniofacial wound.

  12. Organic structures design applications in optical and electronic devices

    CERN Document Server

    Chow, Tahsin J

    2014-01-01

    ""Presenting an overview of the syntheses and properties of organic molecules and their applications in optical and electronic devices, this book covers aspects concerning theoretical modeling for electron transfer, solution-processed micro- and nanomaterials, donor-acceptor cyclophanes, molecular motors, organogels, polyazaacenes, fluorogenic sensors based on calix[4]arenes, and organic light-emitting diodes. The publication of this book is timely because these topics have become very popular nowadays. The book is definitely an excellent reference for scientists working in these a

  13. Carbon nanotubes based vacuum gauge

    Science.gov (United States)

    Rudyk, N. N.; Il’in, O. I.; Il’ina, M. V.; Fedotov, A. A.; Klimin, V. S.; Ageev, O. A.

    2017-11-01

    We have created an ionization type Vacuum gauge with sensor element based on an array of vertically aligned carbon nanotubes. Obtained asymmetrical current-voltage characteristics at different voltage polarity on the electrode with the CNTs. It was found that when applying a negative potential on an electrode with the CNTs, the current in the gap is higher than at a positive potential. In the pressure range of 1 ÷ 103 Torr vacuum gauge sensitivity was 6 mV/Torr (at a current of 4.5·10-5 A) and in the range of 10-5 ÷ 1 Torr was 10 mV/Torr (at a current of 1.3·10-5 A). It is shown that the energy efficiency of vacuum gauge can be increased in the case where electrode with CNT operates as an emitter of electrons.

  14. Band gaps induced by vacuum photons in closed semiconductor cavities

    OpenAIRE

    Kibis, O. V.; Arnardottir, K. B.; Shelykh, I. A.

    2014-01-01

    We consider theoretically a closed (zero-dimensional) semiconductor microcavity where confined vacuum photonic mode is coupled to electrons in valence band of the semiconductor. It is shown that vacuum-induced virtual electron transitions between valence and conduction bands result in renormalization of electron energy spectrum. As a consequence, vacuum-induced band gaps appear within the valence band. Calculated values of the band gaps are of sub-meV scale, that makes this QED effect to be m...

  15. Fabrication of graphene from graphite by a thermal assisted vacuum arc discharge system

    Science.gov (United States)

    Cheng, Guo-Wei; Chu, Kevin; Chen, Jeng Shiung; Tsai, Jeff T. H.

    2017-04-01

    In this study, graphene was fabricated on copper foils using a high temperature furnace embedded in a vacuum arc discharge method. Combining the advantages of chemical vapor deposition and vacuum arc discharge, single-layer graphene can be fabricated at 600 °C base temperature from the mini furnace embedded with a fast heating via the photon radiation from the vacuum arc to 1100 °C on the substrates' surface. The optimal fabrication condition was determined through a series of experiments on ambient pressure, processing time, arc currents, and the cooling process. Observations by scanning electron microscopy, Raman spectroscopy, and optical microscopy showed that the main products were single-layer graphene, which has a uniform thickness across the entire substrate. The results demonstrated that the combination of a vacuum arc with a thermal method that uses graphite as a carbon source provides a low-cost and straight forward method to synthesize graphene films for graphene-based applications.

  16. Relativistic Shear Flow between Electron-Ion and Electron-Positron Plasmas and Astrophysical Applications

    Science.gov (United States)

    Liang, Edison; Fu, Wen; Böttcher, Markus

    2017-10-01

    We present particle-in-cell simulation results of relativistic shear boundary layers between electron-ion and electron-positron plasmas and discuss their potential applications to astrophysics. Specifically, we find that in the case of a fast electron-positron spine surrounded by a slow-moving or stationary electron-ion sheath, lepton acceleration proceeds in a highly anisotropic manner due to electromagnetic fields created at the shear interface. While the highest-energy leptons still produce a beaming pattern (as seen in the quasi-stationary frame of the sheath) of order 1/Γ, where Γ is the bulk Lorentz factor of the spine, for lower-energy particles, the beaming is much less pronounced. This is in stark contrast to the case of pure electron-ion shear layers, in which anisotropic particle acceleration leads to significantly narrower beaming patterns than 1/Γ for the highest-energy particles. In either case, shear-layer acceleration is expected to produce strongly angle-dependent lepton (hence, emanating radiation) spectra, with a significantly harder spectrum in the forward direction than viewed from larger off-axis angles, much beyond the regular Doppler boosting effect from a co-moving isotropic lepton distribution. This may solve the problem of the need for high (and apparently arbitrarily chosen) minimum Lorentz factors of radiating electrons, often plaguing current blazar and GRB jet modeling efforts.

  17. Reliability Oriented Circuit Design For Power Electronics Applications

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Cristian

    for improving the reliability is by active thermal control of the power electronic devices. The work developed during the Ph.D. studies the above mentioned topics, and is divided into two main parts: the first part develops a reliability-oriented design tool which is using a long term real-field mission....... The temperature variation of the semiconductor devices plays a key role in the robustness design and reliability of power electronics converters. This factor has a major impact on the power converters used in renewable energy systems, like solar and wind energy applications, due to the fluctuating nature......-profile as input and the second part propose an advanced gatedriver concept for enhancing the reliability of the power electronics devices. Chapter 1 introduce the emerging challenges of a design tool for reliability and which are the main methods for achieving active thermal control of the devices. To overcome...

  18. Electronic noses and their applications in environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hashem, S.; Keller, P.E.; Kouzes, R.T.; Kangas, L.J. [Pacific Northwest Lab., Richland, WA (United States)

    1995-12-31

    Compact, portable systems capable of quickly identifying contaminants in the field are of great importance when monitoring the environment. In this paper, we examine the effectiveness of using artificial neural networks for real-time data analysis of a sensor array. Analyzing the sensor data in parallel may allow for rapid identification of contaminants in the field without requiring highly selective component sensors. A sensor array combined with a data analysis module is referred to as an electronic nose. In this paper, we investigate the trade off between sensor sensitivity and selectivity relating to the applications of neural network based-electronic noses in environmental monitoring. We use a prototype electronic nose which consists of nine tin-oxide Taguchi-type sensors, a temperature sensor, and a humidity sensor. We illustrate that by using neural network based analysis of a sensor data, the selectivity of a sensor array may be significantly improved, especially when some (or all) sensors are not highly selective.

  19. Multiphysics coupling between periodic gear mesh excitation and input/output fluctuating torques: Application to a roots vacuum pump

    Science.gov (United States)

    Garambois, Pierre; Donnard, Guillaume; Rigaud, Emmanuel; Perret-Liaudet, Joël

    2017-09-01

    This paper presents the analysis of multiphysics coupling between periodic gear mesh excitation and upstream/downstream fluctuating loads using an iterative spectral methodology. This one is based on the resolution of the parametric equations of motion in the spectral domain. Its efficiency makes possible to treat both low and high frequency excitations for systems having a large number of degrees-of-freedom. The different excitation sources, the dynamic coupled equations of motion, the spectral methodology and the iterative resolution principle are described. The dynamic responses of a roots vacuum pump for which the spur gear high mesh frequency parametric excitation is coupled with a low fluidic drag torque frequency. The coupling between excitations generates a frequency enrichment of the dynamic response which is reflected on waterfall plots by emergence of numerous sidebands around harmonics of the mesh frequency.

  20. The application of similar image retrieval in electronic commerce.

    Science.gov (United States)

    Hu, YuPing; Yin, Hua; Han, Dezhi; Yu, Fei

    2014-01-01

    Traditional online shopping platform (OSP), which searches product information by keywords, faces three problems: indirect search mode, large search space, and inaccuracy in search results. For solving these problems, we discuss and research the application of similar image retrieval in electronic commerce. Aiming at improving the network customers' experience and providing merchants with the accuracy of advertising, we design a reasonable and extensive electronic commerce application system, which includes three subsystems: image search display subsystem, image search subsystem, and product information collecting subsystem. This system can provide seamless connection between information platform and OSP, on which consumers can automatically and directly search similar images according to the pictures from information platform. At the same time, it can be used to provide accuracy of internet marketing for enterprises. The experiment shows the efficiency of constructing the system.

  1. The Application of Similar Image Retrieval in Electronic Commerce

    Science.gov (United States)

    Hu, YuPing; Yin, Hua; Han, Dezhi; Yu, Fei

    2014-01-01

    Traditional online shopping platform (OSP), which searches product information by keywords, faces three problems: indirect search mode, large search space, and inaccuracy in search results. For solving these problems, we discuss and research the application of similar image retrieval in electronic commerce. Aiming at improving the network customers' experience and providing merchants with the accuracy of advertising, we design a reasonable and extensive electronic commerce application system, which includes three subsystems: image search display subsystem, image search subsystem, and product information collecting subsystem. This system can provide seamless connection between information platform and OSP, on which consumers can automatically and directly search similar images according to the pictures from information platform. At the same time, it can be used to provide accuracy of internet marketing for enterprises. The experiment shows the efficiency of constructing the system. PMID:24883411

  2. The Application of Similar Image Retrieval in Electronic Commerce

    Directory of Open Access Journals (Sweden)

    YuPing Hu

    2014-01-01

    Full Text Available Traditional online shopping platform (OSP, which searches product information by keywords, faces three problems: indirect search mode, large search space, and inaccuracy in search results. For solving these problems, we discuss and research the application of similar image retrieval in electronic commerce. Aiming at improving the network customers’ experience and providing merchants with the accuracy of advertising, we design a reasonable and extensive electronic commerce application system, which includes three subsystems: image search display subsystem, image search subsystem, and product information collecting subsystem. This system can provide seamless connection between information platform and OSP, on which consumers can automatically and directly search similar images according to the pictures from information platform. At the same time, it can be used to provide accuracy of internet marketing for enterprises. The experiment shows the efficiency of constructing the system.

  3. Transformers and inductors for power electronics theory, design and applications

    CERN Document Server

    Hurley, WG

    2013-01-01

    Based on the fundamentals of electromagnetics, this clear and concise text explains basic and applied principles of transformer and inductor design for power electronic applications. It details both the theory and practice of inductors and transformers employed to filter currents, store electromagnetic energy, provide physical isolation between circuits, and perform stepping up and down of DC and AC voltages. The authors present a broad range of applications from modern power conversion systems. They provide rigorous design guidelines based on a robust methodology for inductor and transform

  4. Trends for Electron Beam Accelerator Applications in Industry

    Science.gov (United States)

    Machi, Sueo

    2011-02-01

    Electron beam (EB) accelerators are major pieces of industrial equipment used for many commercial radiation processing applications. The industrial use of EB accelerators has a history of more than 50 years and is still growing in terms of both its economic scale and new applications. Major applications involve the modification of polymeric materials to create value-added products, such as heat-resistant wires, heat-shrinkable sheets, automobile tires, foamed plastics, battery separators and hydrogel wound dressing. The surface curing of coatings and printing inks is a growing application for low energy electron accelerators, resulting in an environmentally friendly and an energy-saving process. Recently there has been the acceptance of the use of EB accelerators in lieu of the radioactive isotope cobalt-60 as a source for sterilizing disposable medical products. Environmental protection by the use of EB accelerators is a new and important field of application. A commercial plant for the cleaning flue gases from a coal-burning power plant is in operation in Poland, employing high power EB accelerators. In Korea, a commercial plant uses EB to clean waste water from a dye factory.

  5. Vacuum technology in the chemical industry

    CERN Document Server

    Jorisch, Wolfgang

    2015-01-01

    Based on the very successful German edition and a seminar held by the German Engineers` Association (VDI) on a regular basis for years now, this English edition has been thoroughly updated and revised to reflect the latest developments. It supplies in particular the special aspects of vacuum technology, applied vacuum pump types and vacuum engineering in the chemical, pharmaceutical and process industry application-segments. The text includes chapters dedicated to latest European regulations for operating in hazardous zones with vacuum systems, methods for process pressure control and regulati

  6. A flexible inkjet printed antenna for wearable electronics applications

    KAUST Repository

    Karimi, Muhammad Akram

    2016-11-02

    Wearable electronics has gained enormous attention since past few years because it is a promising technology to enhance the human experience. This paper shows a modified inverted-F antenna (IFA), inkjet printed directly on the fabric. A flexible and UV curable interface layer has been used to reduce the surface roughness of the fabric to realize the antenna on top of fabric with fine features. Flexibility tests of the prototype confirm the viability of the design for the wearable applications.

  7. Vacuum deposition onto webs, films and foils

    CERN Document Server

    Bishop, Charles A

    2011-01-01

    Roll-to-roll vacuum deposition is the technology that applies an even coating to a flexible material that can be held on a roll and provides a much faster and cheaper method of bulk coating than deposition onto single pieces or non-flexible surfaces, such as glass. This technology has been used in industrial-scale applications for some time, including a wide range of metalized packaging (e.g. snack packets). Its potential as a high-speed, scalable process has seen an increasing range of new products emerging that employ this cost-effective technology: solar energy products are moving from rigid panels onto flexible substrates, which are cheaper and more versatile; in a similar way, electronic circuit 'boards' can be produced on a flexible polymer, creating a new range of 'flexible electronics' products; and, flexible displays are another area of new technology in vacuum coating, with flexible display panels and light sources emerging. Charles Bishop has written this book to meet the need he identified, as a t...

  8. Electrically and Thermally Conducting Nanocomposites for Electronic Applications

    Directory of Open Access Journals (Sweden)

    Daryl Santos

    2010-02-01

    Full Text Available Nanocomposites made up of polymer matrices and carbon nanotubes are a class of advanced materials with great application potential in electronics packaging. Nanocomposites with carbon nanotubes as fillers have been designed with the aim of exploiting the high thermal, electrical and mechanical properties characteristic of carbon nanotubes. Heat dissipation in electronic devices requires interface materials with high thermal conductivity. Here, current developments and challenges in the application of nanotubes as fillers in polymer matrices are explored. The blending together of nanotubes and polymers result in what are known as nanocomposites. Among the most pressing current issues related to nanocomposite fabrication are (i dispersion of carbon nanotubes in the polymer host, (ii carbon nanotube-polymer interaction and the nature of the interface, and (iii alignment of carbon nanotubes in a polymer matrix. These issues are believed to be directly related to the electrical and thermal performance of nanocomposites. The recent progress in the fabrication of nanocomposites with carbon nanotubes as fillers and their potential application in electronics packaging as thermal interface materials is also reported.

  9. Applications of Silicon Carbide for High Temperature Electronics and Sensors

    Science.gov (United States)

    Shields, Virgil B.

    1995-01-01

    Silicon carbide (SiC) is a wide bandgap material that shows great promise in high-power and high temperature electronics applications because of its high thermal conductivity and high breakdown electrical field. The excellent physical and electronic properties of SiC allows the fabrication of devices that can operate at higher temperatures and power levels than devices produced from either silicon or GaAs. Although modern electronics depends primarily upon silicon based devices, this material is not capable of handling may special requirements. Devices which operate at high speeds, at high power levels and are to be used in extreme environments at high temperatures and high radiation levels need other materials with wider bandgaps than that of silicon. Many space and terrestrial applications also have a requirement for wide bandgap materials. SiC also has great potential for high power and frequency operation due to a high saturated drift velocity. The wide bandgap allows for unique optoelectronic applications, that include blue light emitting diodes and ultraviolet photodetectors. New areas involving gas sensing and telecommunications offer significant promise. Overall, the properties of SiC make it one of the best prospects for extending the capabilities and operational regimes of the current semiconductor device technology.

  10. [Special applications in health telematics: electronic prescription/electronic patient file/digital archiving].

    Science.gov (United States)

    Brenner, G

    2001-10-01

    Our challenge for the upcoming years is the development and the implementation of telematic applications that allow the exchange of data between different sectors of the health care system by a network system. Although most of the techniques already exist today, our highly administrated health care system makes further developments difficult. The communication process is subject to conventional procedures that have to be agreed upon between the contracting parties. The aim is to implement a common electronic communication platform for the health care system which can be accessed by all users. For this purpose, the implementation of electronic prescriptions (digital transmission of data that are up to now communicated from the physicians' office to the pharmacy in paper form) and of electronic patient files (structured documentations of findings according to standards agreed upon between the contracting parties) are of fundamental importance.

  11. Vacuum sewerage system: an appropriate and economical ...

    African Journals Online (AJOL)

    However, vacuum technology has grown enormously in the last years. This paper reviews the applicability of the vacuum system as opposed to gravity systems, especially in Botswana. It is based on the training and visits to installed systems at Shoshong (Botswana), Dubai (UAE) and Hanau (Germany) offered by Roediger ...

  12. New-type spin polarized electron source and its applications; Atarashii spin henkyoku denshi sengen to sono oyo

    Energy Technology Data Exchange (ETDEWEB)

    Saka, T.; Kato, T. [Daido Steel Co. Ltd., Nagoya (Japan); Nakanishi, T.; Okumi, S. [Nagoya University, Nagoya (Japan); Horinaka, H. [Osaka Prefectural University, Osaka (Japan). College of Engineering

    1998-08-20

    This paper reveals that using distorted thin GaAs film can realize high polarization in spin polarized electron ray, and introduces properties of the developed ray source. The paper also touches on the application thereof to property physics. Realization of the high spin polarization is based on use of the `optical polarization method`. With this method, electrons in specific spin state are excited into a conduction band by utilizing the selection law used when valency electrons of zincblende type crystal such as GaAs absorb circular polarization. These electrons are taken out into vacuum and used as polarized electron beams. In order to realize uniformly distorted GaAs film, a method was discussed, with which the thin GaAs films are grown on substrates with different lattice constants, and the films are distorted by means of lattice mismatch. GaAs(1-x)Px was used for the substrates. GaAs(1-x)Px has the lattice constant decrease as the P`s mixed crystal ratio `x` increases. If a thin GaAs film is grown on this substrate, it is possible to obtain GaAs which is subjected to compression stress in the direction parallel with the growing surface, and tensile stress in the vertical direction. 13 refs., 5 figs., 1 tab.

  13. Quantum vacuum noise in physics and cosmology.

    Science.gov (United States)

    Davies, P. C. W.

    2001-09-01

    The concept of the vacuum in quantum field theory is a subtle one. Vacuum states have a rich and complex set of properties that produce distinctive, though usually exceedingly small, physical effects. Quantum vacuum noise is familiar in optical and electronic devices, but in this paper I wish to consider extending the discussion to systems in which gravitation, or large accelerations, are important. This leads to the prediction of vacuum friction: The quantum vacuum can act in a manner reminiscent of a viscous fluid. One result is that rapidly changing gravitational fields can create particles from the vacuum, and in turn the backreaction on the gravitational dynamics operates like a damping force. I consider such effects in early universe cosmology and the theory of quantum black holes, including the possibility that the large-scale structure of the universe might be produced by quantum vacuum noise in an early inflationary phase. I also discuss the curious phenomenon that an observer who accelerates through a quantum vacuum perceives a bath of thermal radiation closely analogous to Hawking radiation from black holes, even though an inertial observer registers no particles. The effects predicted raise very deep and unresolved issues about the nature of quantum particles, the role of the observer, and the relationship between the quantum vacuum and the concepts of information and entropy. (c) 2001 American Institute of Physics.

  14. Vacuum Cleaner Fan Being Improved

    Science.gov (United States)

    Tweedt, Daniel L.

    1997-01-01

    As part of the technology utilization program at the NASA Lewis Research Center, efforts are underway to transfer aerospace technologies to new areas of practical application. One such effort involves using advanced computational fluid dynamics (CFD) codes for turbomachinery to analyze the internal fluid dynamics of low-speed fans and blowers. This year, the Kirby Company in Cleveland, Ohio, approached NASA with a request for technologies that could help them improve their vacuum cleaners. Of particular interest to Kirby is the high-frequency blade-passing noise generation of their vacuum cleaner fan at low airflow rates.

  15. Leuconostoc carnosum 4010 has the potential for use as a protective culture for vacuum-packed meats: culture isolation, bacteriocin identification, and meat application experiments

    DEFF Research Database (Denmark)

    Budde, B.B.; Hornbæk, T.; Jacobsen, T.

    2003-01-01

    -packed meat products and examined for antibacterial activity. Bacteriocin-producing colonies were isolated from 46% of the packages examined. Leuc. carnosum was the predominant bacteriocin-producing strain and Leuc. carnosum 4010 was selected for further experiments because it showed strong antilisterial...... activity corresponding to molecular sizes of 4.6 and 5.3 kDa. N-terminal amino acid sequencing showed that Leuc. carnosum 4010 produced two bacteriocins highly similar or identical to leucocin A and leucocin C. Application experiments showed that the addition of 10(7) cfu/g Leuc. carnosum 4010 to a vacuum-packaged...... activity without producing any undesirable flavour components in meat products. For identification of the bacteriocins produced, partial purification was carried out by ammonium sulphate precipitation, dialysis, and cation exchange chromatography. SDS-PAGE analysis revealed two bands with inhibitory...

  16. Vacuum-free, maskless patterning of Ni electrodes by laser reductive sintering of NiO nanoparticle ink and its application to transparent conductors.

    Science.gov (United States)

    Lee, Daeho; Paeng, Dongwoo; Park, Hee K; Grigoropoulos, Costas P

    2014-10-28

    We introduce a method for direct patterning of Ni electrodes through selective laser direct writing (LDW) of NiO nanoparticle (NP) ink. High-resolution Ni patterns are generated from NiO NP thin films by a vacuum-free, lithography-free, and solution-processable route. In particular, a continuous wave laser is used for the LDW reductive sintering of the metal oxide under ambient conditions with the aid of reducing agents in the ink solvent. Thin (∼ 40 nm) Ni electrodes of glossy metallic surfaces with smooth morphology and excellent edge definition can be fabricated. By applying this method, we demonstrate a high transmittance (>87%), electrically conducting panel for a touch screen panel application. The resistivity of the Ni electrode is less than an order of magnitude higher compared to that of the bulk Ni. Mechanical bending test, tape-pull test, and ultrasonic bath test confirm the robust adhesion of the electrodes on glass and polymer substrates.

  17. Electronic and photonic application of C60. Denki denshi kogaku eno oyo

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, T. (NTT Interdisciplinary Research Laboratories, Tokyo (Japan))

    1994-01-20

    This paper describes the following matters related to application of photonic and electronic characteristics of Fullerene: C60 crystals precipitated from benzene aqueous solution have an fcc structure and an hcp structure mixed, with its mixing ratio depending on hysteresis of test specimens. Mono-crystal thin films of C60 and C70 can be formed on mica substrates by means of a vacuum deposition process. On a CaF2 (111) substrate under normal temperature, a C60 thin film with the fcc structure grows in a single direction in the plane having its (111) plane paralleled with the substrate face. However, on a substrate under elevated temperatures, the film grows in two different directions in the plane, making grid conformity better in C60 and CaF2. Thin films of C60 and C70 transfer to a low temperature phase at a temperature of about 260 K or lower. Carbon nanocapsules containing LaC2 monocrystals can be obtained from arc discharge of a graphite electrode containing La oxides. The paper introduces nonlinear optical characteristics of C60 and C70 thin films, and light conductive polymers doped with C6O and C70. 39 refs., 10 figs.

  18. Qualification of electron-beam welded joints between copper and stainless steel for cryogenic application

    Science.gov (United States)

    Lusch, C.; Borsch, M.; Heidt, C.; Magginetti, N.; Sas, J.; Weiss, K.-P.; Grohmann, S.

    2015-12-01

    Joints between copper and stainless steel are commonly applied in cryogenic systems. A relatively new and increasingly important method to combine these materials is electron-beam (EB) welding. Typically, welds in cryogenic applications need to withstand a temperature range from 300K down to 4K, and pressures of several MPa. However, few data are available for classifying EB welds between OFHC copper and 316L stainless steel. A broad test program was conducted in order to qualify this kind of weld. The experiments started with the measurement of the hardness in the weld area. To verify the leak-tightness of the joints, integral helium leak tests at operating pressures of 16 MPa were carried out at room- and at liquid nitrogen temperature. The tests were followed by destructive tensile tests at room temperature, at liquid nitrogen and at liquid helium temperatures, yielding information on the yield strength and the ultimate tensile strength of the welds at these temperatures. Moreover, nondestructive tensile tests up to the yield strength, i.e. the range in which the weld can be stressed during operation, were performed. Also, the behavior of the weld upon temperature fluctuations between room- and liquid nitrogen temperature was tested. The results of the qualification indicate that EB welded joints between OFHC copper and 316L stainless steel are reliable and present an interesting alternative to other technologies such as vacuum brazing or friction welding.

  19. III - V semiconductor structures for biosensor and molecular electronics applications

    Energy Technology Data Exchange (ETDEWEB)

    Luber, S.M.

    2007-01-15

    The present work reports on the employment of III-V semiconductor structures to biosensor and molecular electronics applications. In the first part a sensor based on a surface-near two dimensional electron gas for a use in biological environment is studied. Such a two dimensional electron gas inherently forms in a molecular beam epitaxy (MBE) grown, doped aluminum gallium arsenide - gallium arsenide (AlGaAs-GaAs) heterostructure. Due to the intrinsic instability of GaAs in aqueous solutions the device is passivated by deposition of a monolayer of 4'-substituted mercaptobiphenyl molecules. The influence of these molecules which bind to the GaAs via a sulfur group is investigated by Kelvin probe measurements in air. They reveal a dependence of GaAs electron affinity on the intrinsic molecular dipole moment of the mercaptobiphenyls. Furthermore, transient surface photovoltage measurements are presented which demonstrate an additional influence of mercaptobiphenyl chemisorption on surface carrier recombination rates. As a next step, the influence of pH-value and salt concentration upon the sensor device is discussed based on the results obtained from sensor conductance measurements in physiological solutions. A dependence of the device surface potential on both parameters due to surface charging is deduced. Model calculations applying Poisson-Boltzmann theory reveal as possible surface charging mechanisms either the adsorption of OH- ions on the surface, or the dissociation of OH groups in surface oxides. A comparison between simulation settings and physical device properties indicate the OH- adsorption as the most probable mechanism. In the second part of the present study the suitability of MBE grown III-V semiconductor structures for molecular electronics applications is examined. In doing so, a method to fabricate nanometer separated, coplanar, metallic electrodes based on the cleavage of a supporting AlGaAs-GaAs heterostructure is presented. This is followed

  20. The use and potential application of electron accelerator in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Danu, Sugiarto [National Nuclear Energy Agency, Center for Research and Development of Isotopes and Radiation Technology, Jakarta (Indonesia)

    2003-02-01

    The use of electron accelerator in Indonesia for research and development, radiation services, commercial purposes and potential application in the future is described. A pilot plant for radiation curing technology particularly for wood surface coating using low energy electron accelerator (300 keV, 50 mA; installed in 1984) and a EBM GJ 2 (2 MeV, 10 mA, installed in 1994) for R and D of crosslinking process such as wire and cable and heat shrinkable tube and sheets in Center for Research and Development of Isotopes and Radiation Technology, Jakarta, and also a low energy electron accelerator (installed in 1998) in a private company, PT Gajah Tunggai, are being mainly used. Their performances are presented with activities achieved in the fields of wood surface coating, vulcanization of natural rubber latex, grafting of polyethylene terephthalate (PET), radiation sterilization, degradation of cellulose and, as promising applications, radiation curing for composite production and uses for environmental preservation are introduced. (S. Ohno)

  1. Application of a Heat Flux Sensor in Wind Power Electronics

    Directory of Open Access Journals (Sweden)

    Elvira Baygildina

    2016-06-01

    Full Text Available This paper proposes and investigates the application of the gradient heat flux sensor (GHFS for measuring the local heat flux in power electronics. Thanks to its thinness, the sensor can be placed between the semiconductor module and the heat sink. The GHFS has high sensitivity and yields direct measurements without an interruption to the normal power device operation, which makes it attractive for power electronics applications. The development of systems for monitoring thermal loading and methods for online detection of degradation and failure of power electronic devices is a topical and crucial task. However, online condition monitoring (CM methods, which include heat flux sensors, have received little research attention so far. In the current research, an insulated-gate bipolar transistor (IGBT module-based test setup with the GHFS implemented on the base plate of one of the IGBTs is introduced. The heat flux experiments and the IGBT power losses obtained by simulations show similar results. The findings give clear evidence that the GHFS can provide an attractive condition monitoring method for the thermal loading of power devices.

  2. Electron Beam Irradiated Intercalated CNT Yarns For Aerospace Applications

    Science.gov (United States)

    Waters, Deborah L.; Gaier, James R.; Williams, Tiffany S.; Lopez Calero, Johnny E.; Ramirez, Christopher; Meador, Michael A.

    2015-01-01

    Multi-walled CNT yarns have been experimentally and commercially created to yield lightweight, high conductivity fibers with good tensile properties for application as electrical wiring and multifunctional tendons. Multifunctional tendons are needed as the cable structures in tensegrity robots for use in planetary exploration. These lightweight robust tendons can provide mechanical strength for movement of the robot in addition to power distribution and data transmission. In aerospace vehicles, such as Orion, electrical wiring and harnessing mass can approach half of the avionics mass. Use of CNT yarns as electrical power and data cables could reduce mass of the wiring by thirty to seventy percent. These fibers have been intercalated with mixed halogens to increase their specific electrical conductivity to that near copper. This conductivity, combined with the superior strength and fatigue resistance makes it an attractive alternative to copper for wiring and multifunctional tendon applications. Electron beam irradiation has been shown to increase mechanical strength in pristine CNT fibers through increased cross-linking. Both pristine and intercalated CNT yarns have been irradiated using a 5-megavolt electron beam for various durations and the conductivities and tensile properties will be discussed. Structural information obtained using a field emission scanning electron microscope, energy dispersive X-ray spectroscopy (EDS), and Raman spectroscopy will correlate microstructural details with bulk properties.

  3. Interfacial microstructures and hardness distributions of vacuum plasma spraying W-coated ODS ferritic steels for fusion plasma facing applications

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Sanghoon, E-mail: shnoh@kaeri.re.kr [Nuclear Materials Division, Korea Atomic Energy Research Institute, Yuseong-gu, Daejeon (Korea, Republic of); Kasada, Ryuta; Kimura, Akihiko [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto (Japan); Nagasaka, Takuya [National Institute for Fusion Science, Toki, Gifu (Japan); Sokolov, Mikhail A. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Kim, Tae Kyu [Nuclear Materials Division, Korea Atomic Energy Research Institute, Yuseong-gu, Daejeon (Korea, Republic of)

    2014-04-15

    In the present study, interfacial microstructures and hardness distributions of W-coated ODS steels as plasma facing structural materials were investigated. A vacuum plasma spraying (VPS) technique was employed to fabricate a W layer on the surface of the ODS ferritic steel substrates. The microstructural observations revealed that the VPS-W has very fine grains aligned toward the spraying direction, and a favorable interface between W and ODS ferritic steels by a mechanical inter-locking without an intermetallic layer. However, crack-type defects were found in VPS-W. Because a brittle inter-diffused layer does not exist at the joint interface, the hardness was gradually distributed in the joint region. After neutron irradiation, irradiation hardening significantly occurred in the VPS-W. However, the hardening of VPS-W was less than that of bulk W irradiated at 773 K. Thus, the VPS is considered to be one of the promising ways to join dissimilar materials between W and ODS steels, which can avoid the formation of an interfacial intermetallic layer and create favorable irradiation hardening resistance on the W coated layer.

  4. Field Emitter Arrays for a Free Electron Laser Application

    CERN Document Server

    Shing-Bruce-Li, Kevin; Ganter, Romain; Gobrecht, Jens; Raguin, Jean Yves; Rivkin, Leonid; Wrulich, Albin F

    2004-01-01

    The development of a new electron gun with the lowest possible emittance would help reducing the total length and cost of a free electron laser. Field emitter arrays (FEAs) are an attractive technology for electron sources of ultra high brightness. Indeed, several thousands of microscopic tips can be deposited on a 1 mm diameter area. Electrons are then extracted by applying voltage to a first grid layer close to the tip apexes, the so called gate layer, and focused by a second grid layer one micrometer above the tips. The typical aperture diameter of the gate and the focusing layer is in the range of one micrometer. One challenge for such cathodes is to produce peak currents in the ampere range since the usual applications of FEAs require less than milliampere. Encouraging peak current performances have been obtained by applying voltage pulses at low frequency between gate and tips. In this paper we report on different tip materials available on the market: diamond FEAs from Extreme Devices Inc., ZrC single ...

  5. Vacuum and ultravacuum physics and technology

    CERN Document Server

    Bello, Igor

    2018-01-01

    Vacuum technology has enormous impact on human life in many aspects and fields, such as metallurgy, material development and production, food and electronic industry, microelectronics, device fabrication, physics, materials science, space science, engineering, chemistry, technology of low temperature, pharmaceutical industry, and biology. All decorative coatings used in jewelries and various daily products—including shiny decorative papers, the surface finish of watches, and light fixtures—are made using vacuum technological processes. Vacuum analytical techniques and vacuum technologies are pillars of the technological processes, material synthesis, deposition, and material analyses—all of which are used in the development of novel materials, increasing the value of industrial products, controlling the technological processes, and ensuring the high product quality. Based on physical models and calculated examples, the book provides a deeper look inside the vacuum physics and technology.

  6. Growth, characterisation and electronic applications of amorphous hydrogenated carbon

    CERN Document Server

    Paul, S

    2000-01-01

    temperature on GaAs, has been studied and concluded to be satisfactory on the basis of good adherence and low leakage currents. Such a structure was motivated by the applicability in Metal Insulator Semiconductor Field Effect Transistors (MISFET). My thesis proposes solutions to a number of riddles associated with the material, hydrogenated amorphous carbon, (a-C:H). This material has lately generated interest in the electronic engineering community, owing to some remarkable properties. The characterisation of amorphous carbon films, grown by radio frequency plasma enhanced chemical vapour deposition has been reported. The coexistence of multiple phases in the same a-C:H film manifests itself in the inconsistent electrical behaviour of different parts of the film, thus rendering it difficult to predict the nature of films. For the first time, in this thesis, a reliable prediction of Schottky contact formation on a-C:H films is reported. A novel and simple development on a Scanning Electron Microscope, configu...

  7. High performance protection circuit for power electronics applications

    Science.gov (United States)

    Tudoran, Cristian D.; Dǎdârlat, Dorin N.; Toşa, Nicoleta; Mişan, Ioan

    2015-12-01

    In this paper we present a high performance protection circuit designed for the power electronics applications where the load currents can increase rapidly and exceed the maximum allowed values, like in the case of high frequency induction heating inverters or high frequency plasma generators. The protection circuit is based on a microcontroller and can be adapted for use on single-phase or three-phase power systems. Its versatility comes from the fact that the circuit can communicate with the protected system, having the role of a "sensor" or it can interrupt the power supply for protection, in this case functioning as an external, independent protection circuit.

  8. Application of FPGA's in Flexible Analogue Electronic Image Generator Design

    Directory of Open Access Journals (Sweden)

    Peter Kulla

    2006-01-01

    Full Text Available This paper focuses on usage of the FPGAs (Field Programmable Gate Arrays Xilinx as a part of our more complex workdedicated to design of flexible analogue electronic images generator for application in TV measurement technique or/and TV servicetechnique or/and education process. The FPGAs performs here the role of component colour R, G, B, synchronization and blanking signals source. These signals are next processed and amplified in other parts of the generator as NTSC/PAL source encoder and RF modulator. The main aim of this paper is to show the possibilities how with suitable development software use a FPGAs in analog TV technology.

  9. High performance protection circuit for power electronics applications

    Energy Technology Data Exchange (ETDEWEB)

    Tudoran, Cristian D., E-mail: cristian.tudoran@itim-cj.ro; Dădârlat, Dorin N.; Toşa, Nicoleta; Mişan, Ioan [National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat, PO 5 Box 700, 400293 Cluj-Napoca (Romania)

    2015-12-23

    In this paper we present a high performance protection circuit designed for the power electronics applications where the load currents can increase rapidly and exceed the maximum allowed values, like in the case of high frequency induction heating inverters or high frequency plasma generators. The protection circuit is based on a microcontroller and can be adapted for use on single-phase or three-phase power systems. Its versatility comes from the fact that the circuit can communicate with the protected system, having the role of a “sensor” or it can interrupt the power supply for protection, in this case functioning as an external, independent protection circuit.

  10. The analysis of web application quality for electronic banking

    OpenAIRE

    Jankovič, Jernej

    2016-01-01

    The purpose of this thesis is to demonstrate a systematic analysis of web applications quality for electronic banking. In the theoretical part we focused on the ISO/IEC 25000 standard, which deals with quality of the product. With help of SQuaRE set of standards we have reviewed the contents of some standards from ISO/IEC 25000 family. At the and we used ISO/IEC 25010 quality model and ISO/IEC 25040 which contains procedure for assessing the product quality. For the assessment of user in...

  11. DC photogun vacuum characterization through photocathode lifetime studies

    Energy Technology Data Exchange (ETDEWEB)

    Marcy Stutzman; Joseph Grames; Matt Poelker; Kenneth Surles-Law; Philip Adderley

    2007-07-02

    Excellent vacuum is essential for long photocathode lifetimes in DC high voltage photoelectron guns. Vacuum Research at Thomas Jefferson National Accelerator Facility has focused on characterizing the existing vacuum systems at the CEBAF polarized photoinjector and on quantifying improvements for new systems. Vacuum chamber preprocessing, full activation of NEG pumps and NEG coating the chamber walls should improve the vacuum within the electron gun, however, pressure measurement is difficult at pressures approaching the extreme-high-vacuum (XHV) region and extractor gauge readings are not significantly different between the improved and original systems. The ultimate test of vacuum in a DC high voltage photogun is the photocathode lifetime, which is limited by the ionization and back-bombardment of residual gasses. Discussion will include our new load-locked gun design as well as lifetime measurements in both our operational and new photo-guns, and the correlations between measured vacuum and lifetimes will be investigated.

  12. Investigation of several dynamic processes on solid surfaces and its application to the extreme high vacuum technology. Kotai hyomenjo no doteki katei no kaimei to sono goku koshinku gijutsu eno oyo

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, D.; Honma, T. (The Univ. of Tokyo, Tokyo (Japan). Inst. of Industrial Science)

    1991-08-26

    This paper makes fundamental studies on several dynamic processes on solid surfaces such as adsorption, desorption, surface segregation, surface precipitation and initial oxidation. The studies aim at applying the information and knowledge obtained to development of an extreme high vacuum technology. Theoretical and technological consideration is given to quantification and precision of surface analytical methods necessary and indispensable for a base technology for the study. The paper pays particular attention to the following three surface analytical methods: Auger electron spectroscopy for a composition analysis, surface extended electron energy loss fine strucutre as a surface short-distance order structural analysis, and thermal sesorption spectroscopy as an adsorption/desorption process analysis. These methods are applied to fundamental studies for development of materials required for creation of an extreme high vacuum. Taking an outgassing phenomenon in the extreme high vacuum as a set of various dynamic processes, quantitative measurement and a mechanism analysis of outgassing are conducted. Actually, the extreme high vacuum is trially produced. 244 refs., 128 figs., 21 tabs.

  13. Fluorinated graphene films with graphene quantum dots for electronic applications

    Energy Technology Data Exchange (ETDEWEB)

    Antonova, I. V., E-mail: antonova@isp.nsc.ru [Rzhanov Institute of Semiconductor Physics, Russian Academy of Sciences, Siberian Branch, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Novosibirsk 630090 (Russian Federation); Nebogatikova, N. A.; Prinz, V. Ya. [Rzhanov Institute of Semiconductor Physics, Russian Academy of Sciences, Siberian Branch, Novosibirsk 630090 (Russian Federation)

    2016-06-14

    This work analyzes carrier transport, the relaxation of non-equilibrium charge, and the electronic structure of fluorinated graphene (FG) films with graphene quantum dots (GQDs). The FG films with GQDs were fabricated by means of chemical functionalization in an aqueous solution of hydrofluoric acid. High fluctuations of potential relief inside the FG barriers have been detected in the range of up to 200 mV. A phenomenological expression that describes the dependence of the time of non-equilibrium charge emission from GQDs on quantum confinement levels and film thickness (potential barrier parameters between GQDs) is suggested. An increase in the degree of functionalization leads to a decrease in GQD size, the removal of the GQD effect on carrier transport, and the relaxation of non-equilibrium charge. The study of the electronic properties of FG films with GQDs has revealed a unipolar resistive switching effect in the films with a relatively high degree of fluorination and a high current modulation (up to ON/OFF ∼ 10{sup 4}–10{sup 5}) in transistor-like structures with a lower degree of fluorination. 2D films with GQDs are believed to have considerable potential for various electronic applications (nonvolatile memory, 2D connections with optical control and logic elements).

  14. Hospital electronic medical record enterprise application strategies: do they matter?

    Science.gov (United States)

    Fareed, Naleef; Ozcan, Yasar A; DeShazo, Jonathan P

    2012-01-01

    Successful implementations and the ability to reap the benefits of electronic medical record (EMR) systems may be correlated with the type of enterprise application strategy that an administrator chooses when acquiring an EMR system. Moreover, identifying the most optimal enterprise application strategy is a task that may have important linkages with hospital performance. This study explored whether hospitals that have adopted differential EMR enterprise application strategies concomitantly differ in their overall efficiency. Specifically, the study examined whether hospitals with a single-vendor strategy had a higher likelihood of being efficient than those with a best-of-breed strategy and whether hospitals with a best-of-suite strategy had a higher probability of being efficient than those with best-of-breed or single-vendor strategies. A conceptual framework was used to formulate testable hypotheses. A retrospective cross-sectional approach using data envelopment analysis was used to obtain efficiency scores of hospitals by EMR enterprise application strategy. A Tobit regression analysis was then used to determine the probability of a hospital being inefficient as related to its EMR enterprise application strategy, while moderating for the hospital's EMR "implementation status" and controlling for hospital and market characteristics. The data envelopment analysis of hospitals suggested that only 32 hospitals were efficient in the study's sample of 2,171 hospitals. The results from the post hoc analysis showed partial support for the hypothesis that hospitals with a best-of-suite strategy were more likely to be efficient than those with a single-vendor strategy. This study underscores the importance of understanding the differences between the three strategies discussed in this article. On the basis of the findings, hospital administrators should consider the efficiency associations that a specific strategy may have compared with another prior to moving toward

  15. Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses

    Energy Technology Data Exchange (ETDEWEB)

    Javedani, J B; Goerz, D A; Houck, T L; Lauer, E J; Speer, R D; Tully, L K; Vogtlin, G E; White, A D

    2007-03-05

    High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions

  16. Wet/Dry Vacuum Cleaner

    Science.gov (United States)

    Reimers, Harold; Andampour, Jay; Kunitser, Craig; Thomas, Ike

    1995-01-01

    Vacuum cleaner collects and retains dust, wet debris, and liquids. Designed for housekeeping on Space Station Freedom, it functions equally well in normal Earth Gravity or in microgravity. Generates acoustic noise at comfortably low levels and includes circuitry that reduces electromagnetic interference to other electronic equipment. Draws materials into bag made of hydrophobic sheet with layers of hydrophilic super-absorbing pads at downstream end material. Hydrophilic material can gel many times its own weight of liquid. Blower also provides secondary airflow to cool its electronic components.

  17. Anaerobic polymers as high vacuum leak sealants

    Science.gov (United States)

    Kendall, B. R. F.

    1982-01-01

    Anaerobic polymers are useful as solventless leak sealants with good vacuum properties at moderate temperatures. Loctite 290 can seal leaks in a range generally encountered in carefully constructed ultrahigh vacuum and high vacuum systems. It was found that small leaks are sealed best under vacuum, whereas large leaks should be sealed at atmospheric pressure. The high-temperature behavior of Loctite 290 is limited by its fast cure, which prevents deep penetration into small leaks; cracking eventually occurs at the entrance to the leak. Repeated thermal cycling to about 300 C is possible, however, provided viscosity, curing time, and leak size are properly matched to ensure penetration into the body of the leak. This may require special formulations for high temperature vacuum applications.

  18. Applications and research on nano power electronics: an adventure beyond quantum electronics

    Science.gov (United States)

    Chakraborty, Arindam; Emadi, Ali

    2005-06-01

    This paper is a roadmap to the exhaustive role of the newly emerging field of nanotechnology in various application and research areas. Some of the today's important topics are plasma, dielectric layer semiconductor, and carbon nanoparticle based technologies. Carbon nanotubes are very useful for the purpose of fabricating nano opto power devices. The basic concept behind tunneling of electrons has been utilized to define another scope of this technology, and thus came many quantum scale tunneling devices and elements. Fabrication of crystal semiconductors of high quality along with oxides of nano aspect would give rise to superior device performance and find applications such as LEDs, LASER, VLSI technology and also in highly efficient solar cells. Many nano-research based organizations are fully devoted to develop nano power cells, which would give birth to new battery cells, tunneling devises, with high power quality, longer lives, and higher activation rates. Different electronics industries as well as the military organizations would be largely benefited due to this major component and system design ideas of 'Smart Power' technologies. The contribution of nano scale power electronics would be realized in various fields like switching devices, electromechanical systems and quantum science. Such a sophisticated technology will have great impact on the modernization of robotics; space systems, automotive systems and many other fields. The highly emerging field of nanomedicine according to specialists would bring a dramatic revolution in the present century. However nanomedicine is nothing but an integration of biology, medicine and technology. Thermoelectric materials as been referred earlier also are used in case of implantable medical equipments for generation of electric power sufficient for those equipments.

  19. Vacuum ultraviolet emission spectrum measurement of a microwave-discharge hydrogen-flow lamp in several configurations: Application to photodesorption of CO ice

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.-J.; Wu, C.-Y. R. [Space Sciences Center and Department of Physics and Astronomy, University of Southern California, Los Angeles, CA 90089-1341 (United States); Chuang, K.-J.; Chu, C.-C.; Yih, T.-S. [Department of Physics, National Central University, Jhongli City, Taoyuan County 32054, Taiwan (China); Muñoz Caro, G. M. [Centro de Astrobiología, INTA-CSIC, Torrejón de Ardoz, E-28850 Madrid (Spain); Nuevo, M. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Ip, W.-H., E-mail: yujung@usc.edu [Graduate Institute of Astronomy, National Central University, Jhongli City, Taoyuan County 32049, Taiwan (China)

    2014-01-20

    We report measurements of the vacuum ultraviolet (VUV) emission spectra of a microwave-discharge hydrogen-flow lamp (MDHL), a common tool in astrochemistry laboratories working on ice VUV photoprocessing. The MDHL provides hydrogen Ly-α (121.6 nm) and H{sub 2} molecular emission in the 110-180 nm range. We show that the spectral characteristics of the VUV light emitted in this range, in particular the relative proportion of Ly-α to molecular emission bands, strongly depend on the pressure of H{sub 2} inside the lamp, the lamp geometry (F type versus T type), the gas used (pure H{sub 2} versus H{sub 2} seeded in He), and the optical properties of the window used (MgF{sub 2} versus CaF{sub 2}). These different configurations are used to study the VUV irradiation of CO ice at 14 K. In contrast to the majority of studies dedicated to the VUV irradiation of astrophysical ice analogs, which have not taken into consideration the emission spectrum of the MDHL, our results show that the processes induced by photons in CO ice from a broad energy range are different and more complex than the sum of individual processes induced by monochromatic sources spanning the same energy range, as a result of the existence of multistate electronic transitions and discrepancy in absorption cross sections between parent molecules and products in the Ly-α and H{sub 2} molecular emission ranges.

  20. High Temperature Wireless Communication And Electronics For Harsh Environment Applications

    Science.gov (United States)

    Hunter, G. W.; Neudeck, P. G.; Beheim, G. M.; Ponchak, G. E.; Chen, L.-Y

    2007-01-01

    In order for future aerospace propulsion systems to meet the increasing requirements for decreased maintenance, improved capability, and increased safety, the inclusion of intelligence into the propulsion system design and operation becomes necessary. These propulsion systems will have to incorporate technology that will monitor propulsion component conditions, analyze the incoming data, and modify operating parameters to optimize propulsion system operations. This implies the development of sensors, actuators, and electronics, with associated packaging, that will be able to operate under the harsh environments present in an engine. However, given the harsh environments inherent in propulsion systems, the development of engine-compatible electronics and sensors is not straightforward. The ability of a sensor system to operate in a given environment often depends as much on the technologies supporting the sensor element as the element itself. If the supporting technology cannot handle the application, then no matter how good the sensor is itself, the sensor system will fail. An example is high temperature environments where supporting technologies are often not capable of operation in engine conditions. Further, for every sensor going into an engine environment, i.e., for every new piece of hardware that improves the in-situ intelligence of the components, communication wires almost always must follow. The communication wires may be within or between parts, or from the engine to the controller. As more hardware is added, more wires, weight, complexity, and potential for unreliability is also introduced. Thus, wireless communication combined with in-situ processing of data would significantly improve the ability to include sensors into high temperature systems and thus lead toward more intelligent engine systems. NASA Glenn Research Center (GRC) is presently leading the development of electronics, communication systems, and sensors capable of prolonged stable

  1. The vacuum disconnector

    Energy Technology Data Exchange (ETDEWEB)

    Schellekens, H.

    1989-05-01

    After showing the extended experience of Holec with vacuum disconnectors, the difficulties encountered in developing the type SVS vacuum bottle are indicated. The implications of demands imposed on price and dimensions are translated into design features. The function and the design of the getter is explained to show how Holec guarantees a 20 year approved vacuum in the bottle. Finally, the results of switching tests are mentioned to explain the reliability and capability of the new disconnector. 12 figs.

  2. Electron beam immobilization of hydrolytic ferments having polyfunctional application

    Energy Technology Data Exchange (ETDEWEB)

    Gonchar, A.M.; Auslender, V.L

    1998-06-01

    We have acquired the experience in the use of the linear electron accelerators type ILU in two main technological directions. The first one is the radiation-induced immobilization of various biologically active substances on polymer matrix. The second one is the radiation-induced linkage of low molecular polyethilenoxides in water solutions at the stage of formation of gels which are used as the basic component in the production of creams, gel-like toothpastes, contact media for ultrasonic diagnostics, absorption pastes. The report describes the production of cellulase complex stabilized on polymer carrier. The immobilization improved the quality of preparation: the pH range is widened with simultaneous increase of activity in more wide working temperature range (up to 70 centigrades). As a result the possibilities of their application for hydrolytic decomposition of cellulose containing materials are increased.

  3. Current and future industrial application of electron accelerators in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Siri-Upathum, Chyagrit [Chulalongkorn Univ., Faculty of Engineering, Bangkok (Thailand)

    2003-02-01

    Industrial applications of electron accelerators in Thailand, first introduced in 1997 for radiation sterilized products such as doctor gown, pampas, feminine napkin etc followed by installation of accelerators, one with energies at 20 MV and the other at 5 MV to produce new value added products like gem stones, topaz, tourmaline and zircon. The machines operate in pulse mode and is also used for irradiation services for food and sterilized products treatment. The need for low and medium energy accelerators in radiation technology is stressed. They are to be used for crosslinking of electrical wire and cable, heat shrinkable materials, low protein concentrated rubber latex, rubber wood furniture and parts, and silk protein degradation. The role of governmental organizations like Nuclear Research Institute (OAEP) and universities in stimulating the utilization of radiation processing in Thailand is strengthened. (S. Ohno)

  4. Virtual screening of electron acceptor materials for organic photovoltaic applications

    Science.gov (United States)

    Halls, Mathew D.; Djurovich, Peter J.; Giesen, David J.; Goldberg, Alexander; Sommer, Jonathan; McAnally, Eric; Thompson, Mark E.

    2013-10-01

    Virtual screening involves the generation of structure libraries, automated analysis to predict properties related to application performance and subsequent screening to identify lead systems and estimate critical structure-property limits across a targeted chemical design space. This approach holds great promise for informing experimental discovery and development efforts for next-generation materials, such as organic semiconductors. In this work, the virtual screening approach is illustrated for nitrogen-substituted pentacene molecules to identify systems for development as electron acceptor materials for use in organic photovoltaic (OPV) devices. A structure library of tetra-azapentacenes (TAPs) was generated by substituting four nitrogens for CH at 12 sites on the pentacene molecular framework. Molecular properties (e.g. ELUMO, Eg and μ) were computed for each candidate structure using hybrid DFT at the B3LYP/6-311G** level of theory. The resulting TAPs library was then analyzed with respect to intrinsic properties associated with OPV acceptor performance. Marcus reorganization energies for charge transport for the most favorable TAP candidates were then calculated to further determine suitability as OPV electron acceptors. The synthesis, characterization and OPV device testing of TAP materials is underway, guided by these results.

  5. Carbon Nanotube Composites for Electronic Packaging Applications: A Review

    Directory of Open Access Journals (Sweden)

    Lavanya Aryasomayajula

    2013-01-01

    Full Text Available Composite engineering comprises of metal matrix composites. They have high strength-weight ratio, better stiffness, economical production, and ease of availability of raw materials. The discovery of carbon nanotubes has opened new possibilities to face challenges better. Carbon Nanotubes are known for their high mechanical strength, excellent thermal and electrical properties. Recent research has made progress in fabricating carbon nanotube metal matrix and polymer-based composites. The methods of fabrication of these composites, their properties and possible applications restricted to the field of electronic packaging have been discussed in this paper. Experimental and theoretical calculations have shown improved mechanical and physical properties like tensile stress, toughness, and improved electrical and thermal properties. They have also demonstrated the ease of production of the composites and their adaptability as one can tailor their properties as per the requirement. This paper reviews work reported on fabricating and characterizing carbon- nanotube-based metal matrix and polymer composites. The focus of this paper is mainly to review the importance of these composites in the field of electronics packaging.

  6. Electronic structure and physical properties of Heusler compounds for thermoelectric and spintronic applications

    Energy Technology Data Exchange (ETDEWEB)

    Ouardi, Siham

    2012-03-19

    This thesis focuses on synthesis as well as investigations of the electronic structure and properties of Heusler compounds for spintronic and thermoelectric applications. The first part reports on the electronic and crystal structure as well as the mechanical, magnetic, and transport properties of the polycrystalline Heusler compound Co{sub 2}MnGe. The crystalline structure was examined in detail by extended X-ray absorption fine structure spectroscopy and anomalous X-ray diffraction. The low-temperature magnetic moment agrees well with the Slater-Pauling rule and indicates a half-metallic ferromagnetic state of the compound, as is predicted by ab-initio calculations. Transport measurements and hard X-ray photoelectron spectroscopy (HAXPES) were performed to explain the electronic structure of the compound. A major part of the thesis deals with a systematical investigation of Heusler compounds for thermoelectric applications. This thesis focuses on the search for new p-type Heusler compounds with high thermoelectric efficiency. The substitutional series NiTi{sub 1-x}M{sub x}Sn (where M=Sc, V and 0electronic structure and transport properties. The results show the possibility to create n-type and p-type thermoelectrics within one Heusler compound. The pure compounds showed n-type behavior, while under Sc substitution the system switched to p-type behavior. A maximum Seebeck coefficient of +230 {mu}V/K (350 K) was obtained for NiTi{sub 0.26}Sc{sub 0.04}Zr{sub 0.35}Hf{sub 0.35}Sn. HAXPES valence band measurement show massive in gap states for the parent compounds NiTiSn, CoTiSb and NiTi{sub 0.3}Zr{sub 0.35}Hf{sub 0.35}Sn. This proves that the electronic states close to the Fermi energy play a key role for the behavior of the transport properties. Furthermore, the electronic structure of the gapless Heusler compounds PtYSb, PtLaBi and PtLuSb were investigated by bulk

  7. Gases and vacua handbook of vacuum physics

    CERN Document Server

    Beck, A H

    2013-01-01

    Handbook of Vacuum Physics, Volume 1: Gases and Vacua presents three major topics, which are the fourth to sixth parts of this volume. These topics are the remarks on units of physical quantities; kinetic theory of gases and gaseous flow; and theory of vacuum diffusion pumps. The first topic aims to present concisely the significance of units of physical quantities, catering the need and interest of those who take measurements and make calculations in different fields of vacuum sciences. The technique and applications of this particular topic are also provided. The second main topic focuses sp

  8. Electronics for guitarists

    CERN Document Server

    Dailey, Denton J

    2014-01-01

    Electronics for Guitarists focuses on analog circuitry, and is written for the guitarist interested in transistor and vacuum tube-based amplifiers. Topics include discrete transistors and diodes, classical filter circuits, and vacuum tube-based amplifiers.

  9. Vacuum-Free, Maskless Patterning of Ni Electrodes by Laser Reductive Sintering of NiO Nanoparticle Ink and Its Application to Transparent Conductors

    KAUST Repository

    Lee, Daeho

    2014-10-28

    © 2014 American Chemical Society. We introduce a method for direct patterning of Ni electrodes through selective laser direct writing (LDW) of NiO nanoparticle (NP) ink. High-resolution Ni patterns are generated from NiO NP thin films by a vacuum-free, lithography-free, and solution-processable route. In particular, a continuous wave laser is used for the LDW reductive sintering of the metal oxide under ambient conditions with the aid of reducing agents in the ink solvent. Thin (∼40 nm) Ni electrodes of glossy metallic surfaces with smooth morphology and excellent edge definition can be fabricated. By applying this method, we demonstrate a high transmittance (>87%), electrically conducting panel for a touch screen panel application. The resistivity of the Ni electrode is less than an order of magnitude higher compared to that of the bulk Ni. Mechanical bending test, tape-pull test, and ultrasonic bath test confirm the robust adhesion of the electrodes on glass and polymer substrates.

  10. Vacuum insulation - Panel properties and building applications. HiPTI - High Performance Thermal Insulation - IEA/ECBCS Annex 39 - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Erb, M. (ed.)

    2005-12-15

    This paper takes a look at the properties of vacuum insulation panels (VIP) that have already been developed some time ago for use in appliances such as refrigerators and deep-freezers. Their insulation performance is a factor of five to ten times better than that of conventional insulation. The paper discusses the use of such panels in buildings to provide thin, highly-insulating constructions for walls, roofs and floors. The motivation for examining the applicability of high performance thermal insulation in buildings is discussed, including solutions where severe space limitations and other technical and aesthetic considerations exist. The use of nano-structured materials and laminated foils is examined and discussed. The questions arising from the use of such panels in buildings is discussed and the open questions and risks involved are examined. Finally, an outlook on the introduction of VIP technology is presented and quality assurance aspects are examined. This work was done within the framework of the Task 39 'High Performance Thermal Insulation' of the 'Energy Conservation in Buildings and Community Systems ECBCS' programme of the International Energy Agency IEA.

  11. GaN Technology for Power Electronic Applications: A Review

    Science.gov (United States)

    Flack, Tyler J.; Pushpakaran, Bejoy N.; Bayne, Stephen B.

    2016-06-01

    Power semiconductor devices based on silicon (Si) are quickly approaching their limits, set by fundamental material properties. In order to address these limitations, new materials for use in devices must be investigated. Wide bandgap materials, such as silicon carbide (SiC) and gallium nitride (GaN) have suitable properties for power electronic applications; however, fabrication of practical devices from these materials may be challenging. SiC technology has matured to point of commercialized devices, whereas GaN requires further research to realize full material potential. This review covers fundamental material properties of GaN as they relate to Si and SiC. This is followed by a discussion of the contemporary issues involved with bulk GaN substrates and their fabrication and a brief overview of how devices are fabricated, both on native GaN substrate material and non-native substrate material. An overview of current device structures, which are being analyzed for use in power switching applications, is then provided; both vertical and lateral device structures are considered. Finally, a brief discussion of prototypes currently employing GaN devices is given.

  12. Comparison of the ultrafast hot electron dynamics of titanium nitride and gold for plasmonic applications

    Science.gov (United States)

    Doiron, Brock; Li, Yi; Mihai, Andrei P.; Cohen, Lesley F.; Petrov, Peter K.; Alford, Neil M.; Oulton, Rupert F.; Maier, Stefan A.

    2017-08-01

    With similar optical properties to gold and high thermal stability, titanium nitride continues to prove itself as a promising plasmonic material for high-temperature applications in the visible and near-infrared. In this work, we use transient pump probe differential reflection measurements to compare the electron energy decay channels in titanium nitride and gold thin films. Using an extended two temperature model to incorporate the photoexcited electrons, it is possible to separate the electron-electron and electron-phonon scattering contributions immediately following the arrival of the pump pulse. This model allows for incredibly accurate determination of the internal electronic properties using only optical measurements. As the electronic properties are key in hot electron applications, we show that titanium nitide has substantially longer electron thermalization and electron-phonon scattering times. With this, we were also able to resolve electron thermal conduction in the film using purely optical measurements.

  13. Introduction to electronics and applications in high energy physics

    CERN Multimedia

    CERN. Geneva

    2004-01-01

    Electronics in HEP experiments: specificities and evolution The Art of Electronics: is there something beyond Ohm's law? Basic building blocks of Analog electronics: quickly understanding a schematic Charge preamps, current preamps and future preamps, shaping and the rest Electronics noise: fundamental and practical Evolution of technology: ASICs, FPGAs...

  14. Applications of CCTO supercapacitor in energy storage and electronics

    Directory of Open Access Journals (Sweden)

    R. K. Pandey

    2013-06-01

    Full Text Available Since the discovery of colossal dielectric constant in CCTO supercapacitor in 2000, development of its practical application to energy storage has been of great interest. In spite of intensive efforts, there has been thus far, no report of proven application. The object of this research is to understand the reason for this lack of success and to find ways to overcome this limitation. Reported herein is the synthesis of our research in ceramic processing of this material and its characterization, particularly with the objective of identifying potential applications. Experimental results have shown that CCTO's permittivity and loss tangent, the two most essential dielectric parameters of fundamental importance for the efficiency of a capacitor device, are intrinsically coupled. They increase or decrease in tandem. Therefore, efforts to simultaneously retain the high permittivity while minimizing the loss tangent of CCTO might not succeed unless an entirely non-typical approach is taken for processing this material. Based on the experimental results and their analysis, it has been identified that it is possible to produce CCTO bulk ceramics with conventional processes having properties that can be exploited for fabricating an efficient energy storage device (EDS. We have additionally identified that CCTO can be used for the development of efficient solid state capacitors of Class II type comparable to the widely used barium titanate (BT capacitors. Based on high temperature studies of the resistivity and the Seebeck coefficient it is found that CCTO is a wide bandgap n-type semiconductor material which could be used for high temperature electronics. The temperature dependence of the linear thermal expansion of CCTO shows the presence of possible phase changes at 220 and 770 °C the origin of which remains unexplained.

  15. Microfabricated triggered vacuum switch

    Science.gov (United States)

    Roesler, Alexander W [Tijeras, NM; Schare, Joshua M [Albuquerque, NM; Bunch, Kyle [Albuquerque, NM

    2010-05-11

    A microfabricated vacuum switch is disclosed which includes a substrate upon which an anode, cathode and trigger electrode are located. A cover is sealed over the substrate under vacuum to complete the vacuum switch. In some embodiments of the present invention, a metal cover can be used in place of the trigger electrode on the substrate. Materials used for the vacuum switch are compatible with high vacuum, relatively high temperature processing. These materials include molybdenum, niobium, copper, tungsten, aluminum and alloys thereof for the anode and cathode. Carbon in the form of graphitic carbon, a diamond-like material, or carbon nanotubes can be used in the trigger electrode. Channels can be optionally formed in the substrate to mitigate against surface breakdown.

  16. Field emission electronics

    CERN Document Server

    Egorov, Nikolay

    2017-01-01

    This book is dedicated to field emission electronics, a promising field at the interface between “classic” vacuum electronics and nanotechnology. In addition to theoretical models, it includes detailed descriptions of experimental and research techniques and production technologies for different types of field emitters based on various construction principles. It particularly focuses on research into and production of field cathodes and electron guns using recently developed nanomaterials and carbon nanotubes. Further, it discusses the applications of field emission cathodes in new technologies such as light sources, flat screens, microwave and X-ray devices.

  17. 75 FR 4343 - Foreign-Trade Zone 22-Chicago, IL; Application for Manufacturing Authority; LG Electronics...

    Science.gov (United States)

    2010-01-27

    ... Electronics MobileComm USA, Inc. (Cell Phone Kitting and Distribution); Bolingbrook, IL An application has..., grantee of FTZ 22, requesting manufacturing authority on behalf of LG Electronics MobileComm USA, Inc...

  18. Insulation vacuum and beam vacuum overpressure release

    CERN Document Server

    Parma, V

    2009-01-01

    There is evidence that the incident of 19th September caused a high pressure build-up inside the cryostat insulation vacuum which the existing overpressure devices could not contain. As a result, high longitudinal forces acting on the insulation vacuum barriers developed and broke the floor and the floor fixations of the SSS with vacuum barriers. The consequent large longitudinal displacements of the SSS damaged chains of adjacent dipole cryo-magnets. Estimates of the helium mass flow and the pressure build- up experienced in the incident are presented together with the pressure build-up for an even more hazardous event, the Maximum Credible Incident (MCI). The strategy of limiting the maximum pressure by the installation of addition pressure relieve devices is presented and discussed. Both beam vacuum lines were ruptured during the incident in sector 3-4 giving rise to both mechanical damage and pollution of the system. The sequence, causes and effects of this damage will be briefly reviewed. We will then an...

  19. Modification of Ultra-High Vacuum Surfaces Using Free Radicals

    CERN Document Server

    Vorlaufer, G

    2002-01-01

    In ultra-high vacuum systems outgassing from vacuum chamber walls and desorption of surface adsorbates are usually the factors which determine pressure and residual gas composition. In particular in beam vacuum systems of accelerators like the LHC, where surfaces are exposed to intense synchrotron radiation and bombardment by energetic ions and electrons, surface properties like the molecular desorption yield or secondary electron yield can strongly influence the performance of the accelerator. Well-established treatment methods like vacuum bake-out or glow-discharge cleaning have been successfully applied in the past to condition ultra-high vacuum surfaces, but these methods are sometimes difficult to carry out, for example if the vacuum chambers are not accessible. In this work, an alternative treatment method is investigated. This method is based on the strong chemical reactivity of free radicals, electrically neutral fragments of molecules. Free radicals (in the case of this work, nitrogen and oxygen radi...

  20. Chalcogenide based materials and devices for flexible electronics applications

    Science.gov (United States)

    Salas-Villasenor, Ana Lizeth

    The scaling of large-area electronics for applications in flat-panel displays, digital X-ray images, and flexible electronics is pushing the technological and cost limits of conventional materials and device processing. Chemical bath deposited chalcogenide films are attractive for thin film transistors (TFTs) for large area electronics given its simple fabrication, low temperature and compatibility with most substrates. In this dissertation, we describe the development of a high performance chalcogenide based TFTs using chemical bath deposition (CBD) methods. Cadmium sulfide (CdS) and lead sulfide (PbS) are used as the TFT channel layer. The influence of several CBD parameters is studied. CBD pH and CdS film thickness have a profound influence on the TFT electrical characteristics. These parameters impact film cluster size and impurity concentration. With the optimized CdS deposition conditions TFTs with excellent electrical properties are demonstrated. With a novel photolithography approach demonstrated here, TFTs with mobilities as high as 18 cm2 /V s, Ion/Ioff of 109 and V T shift of less than 0.1 eV were fabricated. To achieve these TFTs characteristics, a variety of contact materials, gate dielectrics, annealing conditions and device structures were studied. The factors affecting VT instability for CdS based TFTs are also presented and correlated to electrode materials, gate dielectrics, and post-annealing. In summary, TFT instability is correlated to traps and impurities at the dielectric/semiconductor and/or in the semiconductor film. In addition, this dissertation demonstrates CdS TFTs integration in hybrid complementary metal-oxide-semiconductor (CMOS) circuits. In particular, logic gates and ferroelectric random access (FRAM) memory cells are demonstrated. Finally, CdS based TFTs on flexible and transparent substrates with excellent stability and mobility of 10-18 cm2/V-s, threshold voltage of 1.6-4.8 V, and Ion/Ioff ratios of 107 are demonstrated. This

  1. Vacuum silicon photomultipliers: Recent developments

    Energy Technology Data Exchange (ETDEWEB)

    Barbarino, Giancarlo [Dipartimento Scienze Fisiche, Università “Federico II” Napoli (Italy); INFN Napoli (Italy); Barbato, Felicia Carla Tiziana [INFN Napoli (Italy); Campajola, Luigi [Dipartimento Scienze Fisiche, Università “Federico II” Napoli (Italy); Asmundis, Riccardo de [INFN Napoli (Italy); De Rosa, Gianfranca [Dipartimento Scienze Fisiche, Università “Federico II” Napoli (Italy); Mollo, Carlos Maximiliano [INFN Napoli (Italy); Vivolo, Daniele, E-mail: vivolo@na.infn.it [Dipartimento Scienze Fisiche, Università “Federico II” Napoli (Italy); INFN Napoli (Italy)

    2013-08-01

    VSiPMT (Vacuum Silicon PhotoMultiplier Tube) is an innovative design for a modern hybrid, high gain, silicon based photodetector based on the combination of a SiPM with a hemispherical vacuum glass PMT standard envelope. In such a device photoelectrons emitted by the photocathode are accelerated and focused by an electric field towards a small focal area covered by the SiPM which therefore acts as an amplifier, thus substituting the classical dynode chain of a PMT. With a view to the realization of a first prototype of VSiPMT our group is carrying out a preliminary work aimed at the study of SiPM performances as an electron detector, including an accurate Geant4-based simulation of the interaction between SiPM and electron beams. In order to perform a full characterization of the SiPM we developed an experimental setup for the extraction and the acceleration of a beam of backward secondary electrons emitted after the bombardment of a carbon foil by a proton beam extracted in a TTT-3 accelerator.

  2. JURISDICTION RULES APPLICABLE TO CONTRACTS CONCLUDED BY ELECTRONIC MEANS

    Directory of Open Access Journals (Sweden)

    MIHAELA GIURANIUC (TUDORACHE

    2011-04-01

    Full Text Available The purpose of this paper is to analyse the legislation, doctrinal opinions and relevant case law regarding the rules of jurisdiction applicable to the cases arising from contracts concluded by electronic means (e-contracts.Considering the elements of foreign origin that often affect this type of contracts, and the lack of a global agreement regarding international jurisdiction and recognition and enforcement of judgements, the objectives pursued by the author are:- identification of rules of jurisdiction applicable to the cases arising from e-contracts,- identification of problems that could arise from law’s interpretation,- issuing of the de lege ferenda proposals.At European Union level, according to the provisions of Brussels I Regulation, as a general rule, actions against a person domiciled in a Member State shall be brought to the courts of that State.According to the same Regulation, cases resulting from a contractual relationship may be decided by the courts of the place of performance of the contractual obligation. In lack of specific jurisdictional rules, the above rules apply to B2B e-contracts. In the case of B2C e-contracts, the consumer can bring proceedings either before the courts of the Member State of his domicile or before the courts of the Member State of the defendant’s domicile. The consumer can only be sued in the Member State of his domicile. The rules protecting the consumer apply if the trader ‘directs its activities’ to the Member State in which the consumer is domiciled. If the defendant is not domiciled in a Member State, the international jurisdiction is determined, in each Member State, according to its national rules of international private laws.

  3. Diamond-like nanocomposites: electronic transport mechanisms and some applications

    Energy Technology Data Exchange (ETDEWEB)

    Dorfman, V.F.; Skotheim, T.A.; Srivatsa, A.R. (Moltech Corporation, Engineering Building, SUNY, Stony Brook, NY (United States)); Bozhko, A.; Khan, I. (Dept. of Physics, Moscow State Univ. (Russia)); Pypkin, B.N. (Moscow Inst. of Controlling Machines, Moscow (Russia)); Borra, R.T.; Zhang, H. (Dept. of Materials Science and Engineering, SUNY, Stony Brook, NY (United States)); Rodichev, D.; Kirpilenko, G. (Inst. of Physical Problems, Zelenograd (Russia))

    1992-05-15

    A new class of electrically conductive diamond-like nanocomposite (DLN) was synthesized in which the conductivity can be varied over 18 orders of magnitude, from 10{sup 14}-10{sup 16} {Omega} cm to 2-4 x 10{sup -4} {Omega} cm. The electron transport mechanisms of the materials as amorphous dielectric, amorphous metal and in an intermediate state were studied. In the highly conducting state, the DLN structure contains a filamentary (on an atomic scale) random metallic network. A variety of metals, including lithium, silver, copper, aluminum, zinc, magnesium, niobium, tantalum, chromium, molybdenum, tungsten, rhenium, iron, cobalt and nickel can be used to form metallic DLN. Conducting DLN materials can be used as Schottky barriers with semiconductors such as silicon and GaAs. Extremely stable metal-dielectric multilayer structures without interfacial structural boundaries were fabricated. The unique combination of diamond-like chemical and mechanical properties and high electrical conductivity opens the possibility for applications of DLN materials in several areas such as microelectronics and stable anode materials for battery technology. (orig.).

  4. Superconducting coplanar waveguide resonators for electron spin resonance applications

    Science.gov (United States)

    Sigillito, A. J.; Jock, R. M.; Tyryshkin, A. M.; Malissa, H.; Lyon, S. A.

    2013-03-01

    Superconducting coplanar waveguide (CPW) resonators are a promising alternative to conventional volume resonators for electron spin resonance (ESR) experiments where the sample volume and thus the number of spins is small. However, the magnetic fields required for ESR could present a problem for Nb superconducting resonators, which can be driven normal. Very thin Nb films (50 nm) and careful alignment of the resonators parallel to the magnetic field avoid driving the Nb normal, but flux trapping can still be an issue. Trapped flux reduces the resonator Q-factor, can lead to resonant frequency instability, and can lead to magnetic field inhomogeneities. At temperatures of 1.9 K and in a magnetic field 0.32 T, we have tested X-band resonators fabricated directly on the surface of a silicon sample. Q-factors in excess of 15,000 have been obtained. A thin layer of GE varnish applied directly to the resonator has been used to glue a sapphire wafer to its surface, and we still find Q-factors of 16,000 or more in the 0.32 T field. ESR applications of these resonators will be discussed. Supported in part by the ARO.

  5. Applications of Organic and Printed Electronics A Technology-Enabled Revolution

    CERN Document Server

    2013-01-01

    Organic and printed electronics can enable a revolution in the applications of electronics and this book offers readers an overview of the state-of-the-art in this rapidly evolving domain.  The potentially low cost, compatibility with flexible substrates and the wealth of devices that characterize organic and printed electronics will make possible applications that go far beyond the well-known displays made with large-area silicon electronics. Since organic electronics are still in their early stage, undergoing transition from lab-scale and prototype activities to production, this book serves as a valuable snapshot of the current landscape of the different devices enabled by this technology, reviewing all applications that are developing and those can be foreseen.   Provides a complete roadmap for organic and printed electronics research and development for the next several years; Includes an overview of the printing processes for organic electronics, along with state of the art applications, such as solar ...

  6. Direct Methanol Fuel Cell Prototype Demonstration for Consumer Electronics Applications

    Energy Technology Data Exchange (ETDEWEB)

    Carlstrom, Charles, M., Jr.

    2009-07-07

    demonstrated robust operation when tested at various orientations, temperatures, and humidity levels. Durability testing has progressed significantly over the course of the program. MEA, engine, and system level steady state testing has demonstrated degradation rates acceptable for initial product introduction. Test duration of over 5000 hrs has been achieved at both the MEA and breadboard system level. P3 level prototype life testing on engines (stacks with reactant conditioning) showed degradation rates comparable to carefully constructed lab fixtures. This was a major improvement over the P2 and P1 engine designs, which exhibited substantial reductions in life and performance between the lab cell and the actual engine. Over the course of the work on the P3 technology set, a platform approach was taken to the system design. By working in this direction, a number of product iterations with substantial market potential were identified. Although the main effort has been the development of a prototype charger for consumer electronic devices, multiple other product concepts were developed during the program showing the wide variety of potential applications.

  7. ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

    Science.gov (United States)

    Garrett, J. W.; Glassford, A. P. M.; Steakley, J. M.

    1994-01-01

    The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a

  8. Secondary electron imaging of monolayer materials inside a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Cretu, Ovidiu, E-mail: cretu.ovidiu@nims.go.jp; Lin, Yung-Chang; Suenaga, Kazutomo [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8565 (Japan)

    2015-08-10

    A scanning transmission electron microscope equipped with a backscattered and secondary electron detector is shown capable to image graphene and hexagonal boron nitride monolayers. Secondary electron contrasts of the two lightest monolayer materials are clearly distinguished from the vacuum level. A signal difference between these two materials is attributed to electronic structure differences, which will influence the escape probabilities of the secondary electrons. Our results show that the secondary electron signal can be used to distinguish between the electronic structures of materials with atomic layer sensitivity, enhancing its applicability as a complementary signal in the analytical microscope.

  9. Cold Vacuum Drying Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the K-Basins (see K-Basins link) in Hanford's 100 Area is a facility called the Cold Vacuum Drying Facility (CVDF).Between 2000 and 2004, workers at the...

  10. Vacuum-assisted delivery

    Science.gov (United States)

    ... the birth canal. The vacuum uses a soft plastic cup that attaches to the baby's head with suction. ... a numbing medicine placed in the vagina. The plastic cup will be placed on the baby's head. Then, ...

  11. Ultra high vacuum technology

    CERN Multimedia

    CERN. Geneva

    2001-01-01

    A short introduction for some basic facts and equations. Subsquently, discussion about: Building blocks of an ultrahigh vacuum system - Various types of pumps required to reach uhv and methods to reduce these effects - Outgassing phenomena induced by the presence of a particle beam and the most common methods to reduce these effects It will be given some practical examples from existing CERN accelerators and discuss the novel features of the future LHC vacuum system.

  12. A Planck Vacuum Cosmology

    Directory of Open Access Journals (Sweden)

    Daywitt W. C.

    2009-04-01

    Full Text Available Both the big-bang and the quasi-steady-state cosmologies originate in some type of Planck state. This paper presents a new cosmological theory based on the Planck- vacuum negative-energy state, a state consisting of a degenerate collection of negative- energy Planck particles. A heuristic look at the Einstein field equation provides a con- vincing argument that such a vacuum state could provide a theoretical explanation for the visible universe.

  13. Improved Aerogel Vacuum Thermal Insulation

    Science.gov (United States)

    Ruemmele, Warren P.; Bue, Grant C.

    2009-01-01

    An improved design concept for aerogel vacuum thermal-insulation panels calls for multiple layers of aerogel sandwiched between layers of aluminized Mylar (or equivalent) poly(ethylene terephthalate), as depicted in the figure. This concept is applicable to both the rigid (brick) form and the flexible (blanket) form of aerogel vacuum thermal-insulation panels. Heretofore, the fabrication of a typical aerogel vacuum insulating panel has involved encapsulation of a single layer of aerogel in poly(ethylene terephthalate) and pumping of gases out of the aerogel-filled volume. A multilayer panel according to the improved design concept is fabricated in basically the same way: Multiple alternating layers of aerogel and aluminized poly(ethylene terephthalate) are assembled, then encapsulated in an outer layer of poly(ethylene terephthalate), and then the volume containing the multilayer structure is evacuated as in the single-layer case. The multilayer concept makes it possible to reduce effective thermal conductivity of a panel below that of a comparable single-layer panel, without adding weight or incurring other performance penalties. Implementation of the multilayer concept is simple and relatively inexpensive, involving only a few additional fabrication steps to assemble the multiple layers prior to evacuation. For a panel of the blanket type, the multilayer concept, affords the additional advantage of reduced stiffness.

  14. Optical electronics self-organized integration and applications

    CERN Document Server

    Yoshimura, Tetsuzo

    2012-01-01

    IntroductionFrom Electronics to Optical ElectronicsAnalysis Tools for Optical CircuitsSelf-Organized Optical Waveguides: Theoretical AnalysisSelf-Organized Optical Waveguides: Experimental DemonstrationsOptical Waveguide Films with Vertical Mirrors 3-D Optical Circuits with Stacked Waveguide Films Heterogeneous Thin-Film Device IntegrationOptical Switches OE Hardware Built by Optical ElectronicsIntegrated Solar Energy Conversion SystemsFuture Challenges.

  15. Applicability of thin film phase plates in biological electron microscopy

    OpenAIRE

    Danev, Radostin; Nagayama, Kuniaki

    2006-01-01

    Presented is an evaluation of phase contrast techniques in transmission electron microscopy. The traditional defocus phase contrast is compared to two recently developed phase plate techniques. One is the Zernike phase contrast transmission electron microscope, the other is the Hilbert differential contrast thransmission electron microscope. The imaging characteristics of each technique are discussed. Phase plate techniques provide improved contrast for ice-embedded biological samples which a...

  16. Vacuum Insulation Panels - Study on VIP-components and panels for service life prediction of VIP in building applications (Subtask A)

    Energy Technology Data Exchange (ETDEWEB)

    Simmler, H.; Brunner, S. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Heinemann, U.; Schwab, H. [Bavarian Centre for Applied Energy Research (ZAE Bayern), Garching (Germany); Kumaran, K.; Mukhopadhyaya, P. [National Research Council, Institute for Research in Construction (NRC-IRC), Ottawa (Canada); Quenard, D.; Sallee, H. [Scientific and Technical Centre for Construction (CSTB), Marne la Vallee (France); Noller, K.; Kuecuekpinar-Niarchos, E.; Stramm, C. [Fraunhofer Institute for Process Engineering and Packaging (IVV), Freising (Germany); Tenpierik, M.; Cauberg, H. [Technical University of Delft, Delft (Netherlands); Erb, M. [Dr. Eicher und Pauli AG (Switzerland)

    2005-09-15

    This comprehensive paper takes a look at the properties of vacuum insulation panels (VIP) and was presented as a contribution to the IEA's ECBCS (Energy Conservation in Buildings and Community Systems) Annex 39. The various institutions in Switzerland, Germany, Canada, France, Sweden and the Netherlands participating in the task and their activities are listed. The paper describes the concept of vacuum insulation for buildings and examines the physics involved and core materials that can be used. The physical, mechanical and thermal properties of the core materials are examined and the requirements placed on the envelope of the panels are looked at. Tests made on materials as well as on the complete vacuum insulation panels are described in detail. The results obtained are presented and reviewed. Service-life and quality assurance aspects are also discussed. A comprehensive appendix completes the report.

  17. Microscopic effective interaction between electrons: Application to sodium clusters

    Science.gov (United States)

    Lipparini, E.; Serra, Ll.; Takayanagi, K.

    1994-06-01

    The effects of short-range electronic correlations on the properties of sodium clusters are studied using the Brueckner g matrix as an effective interaction which describes the scattering of two electrons in the presence of a many-electron medium. The associated cluster Hamiltonian is solved within the Hartree-Fock approximation for the ground state and the dipole plasmon resonance is studied using the self-consistent random-phase approximation. Effects due to ionic core electrons are considered within the pseudojellium model of metal cluster, which goes beyond jellium by using ionic pseudo-Hamiltonians.

  18. 76 FR 6186 - Applications for Membership on the Electronic Tax Administration Advisory Committee (ETAAC)

    Science.gov (United States)

    2011-02-03

    ... on the Electronic Tax Administration Advisory Committee (ETAAC) AGENCY: Internal Revenue Service (IRS... applications of individuals to be considered for membership on the Electronic Tax Administration Advisory... IRS' strategy for electronic tax administration. The ETAAC also provides an organized public forum for...

  19. Application of the electronic educational resources in the higher educational institution

    Directory of Open Access Journals (Sweden)

    Александр Петрович Колошеин

    2014-12-01

    Full Text Available In article approaches to effective application of electronic educational resources are described. The analysis of methods and forms of education in higher education institution is carried out, the principles of application of the electronic educational resources, adequate to used methods and forms of education are established.

  20. Application of the electronic educational resources in the higher educational institution

    OpenAIRE

    Александр Петрович Колошеин

    2014-01-01

    In article approaches to effective application of electronic educational resources are described. The analysis of methods and forms of education in higher education institution is carried out, the principles of application of the electronic educational resources, adequate to used methods and forms of education are established.

  1. Bake-Out Mobile Controls for Large Vacuum Systems

    CERN Document Server

    Blanchard, S; Gomes, P; Pereira, H; Kopylov, L; Merker, S; Mikheev, M

    2014-01-01

    Large vacuum systems at CERN (Large Hadron Collider - LHC, Low Energy Ion Rings - LEIR...) require bake-out to achieve ultra-high vacuum specifications. The bake-out cycle is used to decrease the outgassing rate of the vacuum vessel and to activate the Non-Evaporable Getter (NEG) thin film. Bake-out control is a Proportional-Integral-Derivative (PID) regulation with complex recipes, interlocks and troubleshooting management and remote control. It is based on mobile Programmable Logic Controller (PLC) cabinets, fieldbus network and Supervisory Control and Data Acquisition (SCADA) application. The CERN vacuum installations include more than 7 km of baked vessels; using mobile cabinets reduces considerably the cost of the control system. The cabinets are installed close to the vacuum vessels during the time of the bake-out cycle. Mobile cabinets can be used in any of the CERN vacuum facilities. Remote control is provided through a fieldbus network and a SCADA application

  2. Correlative light and electron microscopy : strategies and applications

    NARCIS (Netherlands)

    Driel, Linda Francina van

    2011-01-01

    Correlative light and electron microscopy (CLEM) refers to the observation of the same structures or ultrastructures with both light microscopy (LM) and electron microscopy (EM). LM provides an overview of the studied material, and enables the quick localization of structures that are fluorescently

  3. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    user

    The use of electron beam to disinfect sewage water is gaining importance. The current problem on environmental health in relation to water pollution insists for the safe disposal of sewage water. In general, sewage water comprises of heterogeneous organic based chemicals as well as pathogens. EB. (electron beam) ...

  4. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    The use of electron beam to disinfect sewage water is gaining importance. The current problem on environmental health in relation to water pollution insists for the safe disposal of sewage water. In general, sewage water comprises of heterogeneous organic based chemicals as well as pathogens. EB (electron beam) ...

  5. Carbon nanotubes--electronic/electrochemical properties and application for nanoelectronics and photonics.

    Science.gov (United States)

    Sgobba, Vito; Guldi, Dirk M

    2009-01-01

    The fundamental chemical, redox, electrochemical, photoelectrochemical, optical and optoelectronic features of carbon nanotubes are surveyed with particular emphasis on the most relevant applications as electron donor/electron acceptor or as electron conductor/hole conductor materials, in solutions and in the solid state. Methods that aim at p- and n-doping as a means to favor hole or electron injection/transport are covered as well (critical review, 208 references).

  6. Development of advanced electron holographic techniques and application to industrial materials and devices.

    Science.gov (United States)

    Yamamoto, Kazuo; Hirayama, Tsukasa; Tanji, Takayoshi

    2013-06-01

    The development of a transmission electron microscope equipped with a field emission gun paved the way for electron holography to be put to practical use in various fields. In this paper, we review three advanced electron holography techniques: on-line real-time electron holography, three-dimensional (3D) tomographic holography and phase-shifting electron holography, which are becoming important techniques for materials science and device engineering. We also describe some applications of electron holography to the analysis of industrial materials and devices: GaAs compound semiconductors, solid oxide fuel cells and all-solid-state lithium ion batteries.

  7. Vacuum ultraviolet detector for gas chromatography.

    Science.gov (United States)

    Schug, Kevin A; Sawicki, Ian; Carlton, Doug D; Fan, Hui; McNair, Harold M; Nimmo, John P; Kroll, Peter; Smuts, Jonathan; Walsh, Phillip; Harrison, Dale

    2014-08-19

    Analytical performance characteristics of a new vacuum ultraviolet (VUV) detector for gas chromatography (GC) are reported. GC-VUV was applied to hydrocarbons, fixed gases, polyaromatic hydrocarbons, fatty acids, pesticides, drugs, and estrogens. Applications were chosen to feature the sensitivity and universal detection capabilities of the VUV detector, especially for cases where mass spectrometry performance has been limited. Virtually all chemical species absorb and have unique gas phase absorption cross sections in the approximately 120-240 nm wavelength range monitored. Spectra are presented, along with the ability to use software for deconvolution of overlapping signals. Some comparisons with experimental synchrotron data and computed theoretical spectra show good agreement, although more work is needed on appropriate computational methods to match the simultaneous broadband electronic and vibronic excitation initiated by the deuterium lamp. Quantitative analysis is governed by Beer-Lambert Law relationships. Mass on-column detection limits reported for representatives of different classes of analytes ranged from 15 (benzene) to 246 pg (water). Linear range measured at peak absorption for benzene was 3-4 orders of magnitude. Importantly, where absorption cross sections are known for analytes, the VUV detector is capable of absolute determination (without calibration) of the number of molecules present in the flow cell in the absence of chemical interferences. This study sets the stage for application of GC-VUV technology across a wide breadth of research areas.

  8. On vacuum-insulated thermal storage

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Benjamin [Georg-Simon-Ohm Univ. of Applied Sciences, Nuernberg (Germany); Technische Univ. Muenchen (Germany). Inst. of Resource and Energy Technology; Hofbeck, Klaus [Georg-Simon-Ohm Univ. of Applied Sciences, Nuernberg (Germany)

    2011-07-01

    Nowadays, the insulation for thermal energy storage (TES) is not as good as it should be. One reason for this is the higher investment cost for better insulation. Nevertheless, most of the recent studies show that the thermal losses of long-term storage have been underestimated. Therefore, recent research studies have focused on vacuum-insulated thermal storage. There are two common concepts with regard to the use of vacuum insulation for thermal storage. On the one hand, the Center for Applied Energy Research (ZAE) in Munich uses an evacuated double vessel filled with pearlite. On the other hand, the Ohm University uses vacuum insulation panels (VIP). Both the insulation concepts are based on the Knudsen effect. Thus, the thermal conductivity is lowered by a factor of 6-10, when compared with the conventional insulation materials, such as EPS, XPS, or mineral wool. Both the concepts are adoptions of the existing insulation applications. The filled double vessel tank is already being used for cryogenic storage for liquid gases. Furthermore, VIPs are being used to insulate passive houses. However, the use of vacuum insulation for thermal energy storage causes different problems due to higher temperatures and moisture. Nevertheless, vacuum insulations are a promising solution for small thermal long-tenn storage. This study presents the first state-of-the-art review on vacuum-insulated thermal tanks.

  9. Vacuum induced photoresist outgassing

    Science.gov (United States)

    Waterman, Justin; Mbanaso, Chimaobi; Denbeaux, Gregory

    2008-03-01

    In order to continue the trend toward smaller feature sizes in lithography, new methods of lithography will be needed. A likely method for printing features 32 nm and smaller is extreme ultraviolet (EUV) lithography. EUV allows for features to be printed that are smaller than the current methods can achieve. However, outgassing of the photoresist is a concern for EUV lithography. The outgassed components can lead to contamination of the optics, degrading the reflectivity and hence lowering throughput of the exposure tools. Outgassing due to EUV exposure has been investigated by many groups. However, there were no complete investigations available of vacuum induced outgassing. In this paper, several methods were employed to investigate the outgassing due to vacuum. It was found that the vacuum induced outgassing outgassed a similar number of molecules as the outgassing due to EUV exposure. Furthermore, almost all of the outgassing was completed after about two minutes in vacuum. To mitigate the potential concern of outgassing due to vacuum causing contamination of optics, this work shows that photoresist coated silicon wafers only require about two minutes of pumping prior to insertion near the optics within EUV lithography tools.

  10. Design of electron beam accelerator for microwave application

    Science.gov (United States)

    Prestwich, K. R.

    Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx 1 microsec) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. Alternatively, a low voltage PFN followed by a highly coupled transformer can be used. Basic design principles for all of the above subsystems are discussed. Both PFLs and PFNs can also be operated as inductive storage systems with opening switches.

  11. Application of electronic nose for industrial odors and gaseous emissions measurement and monitoring--An overview.

    Science.gov (United States)

    Deshmukh, Sharvari; Bandyopadhyay, Rajib; Bhattacharyya, Nabarun; Pandey, R A; Jana, Arun

    2015-11-01

    The present review evaluates the key modules of the electronic nose, a biomimetic system, with specific examples of applications to industrial emissions monitoring and measurement. Regulations concerning the odor control are becoming very strict, due to ever mounting environmental pollution and its subsequent consequences and it is advantageous to employ real time measurement system. In this perspective, systems like the electronic nose are an improved substitute for assessing the complex industrial emissions over other analytical techniques (odorant concentration measurement) and olfactometry (odor concentration measurement). Compared to tools like gas chromatography, electronic nose systems are easy to develop, are non-destructive and useful for both laboratory and on field purposes. Although there has been immense development of more sensitive and selective sensor arrays and advanced data mining techniques, there have been limited reports on the application of electronic nose for the measurement of industrial emissions. The current study sheds light on the practical applicability of electronic nose for the effective industrial odor and gaseous emissions measurement. The applications categorization is based on gaseous pollutants released from the industries. Calibration and calibration transfer methodologies have been discussed to enhance the applicability of electronic nose system. Further, industrial gas grab sampling technique is reviewed. Lastly, the electronic mucosa system, which has the ability to overcome the flaws of electronic nose system, has been examined. The review ends with the concluding remarks describing the pros and cons of artificial olfaction technique for the industrial applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Improving Vacuum Cleaners

    Science.gov (United States)

    1997-01-01

    Under a Space Act Agreement between the Kirby company and Lewis Research Center, NASA technology was applied to a commercial vacuum cleaner product line. Kirby engineers were interested in advanced operational concepts, such as particle flow behavior and vibration, critical factors to improve vacuum cleaner performance. An evaluation of the company 1994 home care system, the Kirby G4, led to the refinement of the new G5 and future models. Under the cooperative agreement, Kirby had access to Lewis' holography equipment, which added insight into how long a vacuum cleaner fan would perform, as well as advanced computer software that can simulate the flow of air through fans. The collaboration resulted in several successes including fan blade redesign and continuing dialogue on how to improve air-flow traits in various nozzle designs.

  13. Baryogenesis in false vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Yuta [KEK Theory Center, IPNS, KEK, Tsukuba, Ibaraki (Japan); Yamada, Masatoshi [Kanazawa University, Institute for Theoretical Physics, Kanazawa (Japan)

    2017-09-15

    The null result in the LHC may indicate that the standard model is not drastically modified up to very high scales, such as the GUT/string scale. Having this in the mind, we suggest a novel leptogenesis scenario realized in the false vacuum of the Higgs field. If the Higgs field develops a large vacuum expectation value in the early universe, a lepton number violating process is enhanced, which we use for baryogenesis. To demonstrate the scenario, several models are discussed. For example, we show that the observed baryon asymmetry is successfully generated in the standard model with higher-dimensional operators. (orig.)

  14. Gap application results for adjacent electron beams treatment

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio, Francisco G.A., E-mail: francisampaio@pg.ffclrp.usp.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Del Lama, Lucas S., E-mail: lucasdellama@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Petchevist, Paulo C.D., E-mail: petchevist12@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Instituto de Radioterapia e Megavoltagem de Ribeirao Preto - IRMEV, Rua Sete de Setembro 1150, CEP 14010-180, Ribeirao Preto, SP (Brazil); Moreira, Marcos V., E-mail: marcos_vasques@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Instituto de Radioterapia e Megavoltagem de Ribeirao Preto - IRMEV, Rua Sete de Setembro 1150, CEP 14010-180, Ribeirao Preto, SP (Brazil); Almeida, Adelaide de, E-mail: dalmeida@ffclrp.usp.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil)

    2011-12-15

    Nowadays, electron beams from high-energy linear accelerators (LINAC) are widely used in a variety of radiotherapy treatments being suitable especially for superficial tumors. Since this sort of ionizing radiation has stopping power higher than photons, deeper and healthier tissues can be preserved. On the other hand, when applying adjacent electron beams, 'hot' spots can be observed, due to penumbra and/or scattering, contributing to the increase of the absorbed dose in the target volume. In this sense, the objective of this work was to investigate the effects of parallel adjacent electron beams using the chemical dosimeter Fricke Xylenol Gel (FXG) and compare the experimental results with ones acquired using Monte Carlo simulation. Thus, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15 and 20 Multiplication-Sign 20 cm{sup 2} fields were irradiated with 5, 8 and 10 MeV electron beams applying different gap widths. The experimental results and the simulations indicated overdose values up to 40% from the prescribed one for the specific tumor. This demonstrates that specific gaps are necessary in the case of treatments with parallel adjacent electron beams in order to prevent overdoses in the depth of interest.

  15. Application of transmission electron tomography for modeling the renal corpuscle.

    Science.gov (United States)

    Cheng, Delfine; Shen, Sylvie; Chen, Xin-Ming; Pollock, Carol; Braet, Filip

    2013-11-01

    Structural alteration to the microanatomical organization of the glomerular filtration barrier results in proteinuria. Conventional transmission electron microscopy is an important diagnostic tool to assess the degree of ultrastructural damage of the corpusclar filtration unit. However, this approach lacks the ability to collect accurate stereological insights in a relative large tissue volume. Transmission electron tomography offers the ability to gather three-dimensional information with relative ease. Therefore, this contribution aims to highlight what electron tomography can bring to the pathologist in this challenging area of diagnostic practice. Kidney tissue was prepared for routine ultrastructural transmission electron microscopy investigation. Three-dimensional data stacks were automatically acquired by tilting semi-thin sections of 270 nm in an angular range of typically -60° to +60° with 1° increment. Subsequently, models of the filtration unit were produced by computer-assisted tracking of structures of interest. This short report illustrates the capability that transmission electron tomography can offer in the fine structure-function assessment of the porous fenestrated glomerular capillary endothelium, the underlying basement membrane and the podocyte filtration slits. Furthermore, this approach allows the generation of morphometric data about size, shape and volume alterations of the kidney's filtration barrier at the nanoscale. Copyright © 2013 Elsevier GmbH. All rights reserved.

  16. A concept of applications in the electronic commerce market

    OpenAIRE

    Oboyanskiy, Andrey; Shuvalova, Mariya

    2017-01-01

    This article considers the potential of mobile applications in the e-commerce. The current state of e-commerce has been considered. The Internet users' involvement in the e-commerce has been analyzed. Analyzed example of the most popular applications for further analysis sphere of e-commerce. The work analyzes the successful e-commerce site on the market. The different concepts for using mobile applications on e-commerce market. Examples of the use of augmented reality applications aimed at p...

  17. APPLICATION OF ELECTRONIC NOSE IN HONEY GEOGRAPHICAL ORIGIN CHARACTERISATION

    Directory of Open Access Journals (Sweden)

    FRANE Čačić

    2009-08-01

    Full Text Available Honey volatile compounds were analysed by means of electronic nose, with the aim to capture honey aroma profile. 49 samples of black locust (Robinia pseudoacacia L. and 16 of chestnut (Castanea sativa Mill. honeys were analysed. Their botanical origin and physicochemical properties were analysed in accredited laboratory Geographical origin of samples has been known from interviews with beekeepers. Data obtained by electronic nose analysis were further analysed by principal component analysis (PCA in order to determine differences among volatile profiles of samples with the same botanical origin but with different geographical origin. PCA result showed that honey samples from geographically close regions tend to group together, while those of distant geographical regions show differences though they are of the same botanical origin. Those results imply possibility to use electronic nose as a tool for honey geographical origin determination.

  18. Application of Similarity in Fault Diagnosis of Power Electronics Circuits

    Science.gov (United States)

    Rongjie, Wang; Yiju, Zhan; Meiqian, Chen; Haifeng, Zhou; Kewei, Guo

    A method of fault diagnosis was proposed for power electronics circuits based on S transforms similarity. At first, the standard module time-frequency matrixes of S transforms for all fault signals were constructed, then the similarity of fault signals' module time-frequency matrixes to standard module time-frequency matrixes were calculated, and according to the principle of maximum similarity, the faults were diagnosed. The simulation result of fault diagnosis of a thyristor in a three-phase full-bridge controlled rectifier shows that the method can accurately diagnose faults and locate the fault element for power electronics circuits, and it has excellent performance for noise robustness and calculation complexity, thus it also has good practical engineering value in the solution to the fault problems for power electronics circuits.

  19. Low energy electron beams for industrial and environmental applications

    CERN Document Server

    Skarda, Vlad

    2017-01-01

    EuCARD-2 Workshop, 8-9 December 2016, Warsaw, Poland. Organizers: Science and Technology Facilities Council, UK CERN - The European Organization for Nuclear Research, Switzerland, Institute of Nuclear Chemistry and Technology, Poland, Fraunhofer Institute for Electron Beam and Plasma Technology, Germany, Warsaw University of Technology, Poland. An article presents short information about EuCARD-2 Workshop “Low energy electron beams for industrial and environmental applications”, which was held in December 2016 in Warsaw. Objectives, main topics and expected output of meeting are described. List of organizers is included.

  20. Monte Carlo method for studies of spin relaxation in degenerate electron gas: Application to monolayer graphene

    Science.gov (United States)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-07-01

    Monte Carlo method allowing to account for the effect of Pauli Exclusion Principle in the case of spin polarized electron gas is demonstrated. Modeling requires calculation of electron states occupancy accounting for the direction of the spin of the scattered electron. As an example of application, calculations for the case of spin and energy relaxation of initially polarized electrons in monolayer graphene have been performed. Model includes D'yakonov-Perel' and Elliot-Yafet relaxation mechanisms. It is demonstrated that electron distribution function and energy relaxation follow the spin polarization relaxation and they are mainly governed by spin related scattering processes.

  1. Applications of Digital Libraries and Electronic Technologies in ...

    African Journals Online (AJOL)

    The paper analyses the corroborative applications offered by different organisations in Uganda and describes prospects for the use of digital libraries in Uganda. A qualitative approach design with a purposive sampling strategy was adopted. The study was limited to practical experiences on the services and applications.

  2. Evolution of gettering technologies for vacuum tubes to getters for MEMS

    Science.gov (United States)

    Amiotti, M.

    2008-05-01

    Getter materials are technically proven and industrially accepted practical ways to maintain vacuum inside hermetically sealed tubes or devices to assure high reliability and long lifetime of the operating devices. The most industrially proven vacuum tube is the cathode rays tubes (CRTs), where large surfaces are available for the deposition of an evaporated barium film by a radio frequency inductive heating of a stainless steel container filled with a BaAl4 powder mixed to Ni powder. The evolution of the CRTs manufacturing technologies required also new types of barium getters able to withstand some thermal process in air without any deterioration of the evaporation characteristics. In other vacuum tubes such as traveling waves tubes, the space available for the evaporation of a barium film and the sorption capacity required to assure the vacuum for the lifetime of the devices did not allow the use of the barium film, prompting the development of sintered non evaporable getter pills that can be activated during the manufacturing process or by flowing current through an embedded resistance. The same sintered non evaporable getter pills could find usage also in evacuated parts to thermally isolate the infrared sensors for different final applications. In high energy physics particle accelerators, the getter technology moved from localized vacuum getter pumps or getter strips to a getter coating over the surface of vacuum chambers in order to guarantee a more uniform pumping speed. With the advent of solid state electronics, new challenges faced the getter technology to assure long life to vacuum or inert gas filled hermetical packages containing microelectronic devices, especially in the telecommunication and military applications. A well known problem of GaAs devices with Pd or Pt metalization is the H2 poisoning of the metal gate: to prevent this degradation a two layer getter film has been develop to absorb a large quantity of H2 per unit of getter surface. The

  3. Fuskite® preliminary experimental tests based on permeation against vacuum for hydrogen recovery as a potential application in Pb15.7Li loop systems.

    Energy Technology Data Exchange (ETDEWEB)

    Sacristán, R., E-mail: mrosa.sacristan@sener.es [SENER Ingeniería y Sistemas, C/ Provença 392, 5a, 08025 Barcelona (Spain); Veredas, G. [EURATOM-CIEMAT Fusion Assoc., Fusion Technology Division, Av. Complutense 40, 28040 Madrid (Spain); Bonjoch, I. [SENER Ingeniería y Sistemas, C/ Provença 392, 5a, 08025 Barcelona (Spain); Peñalva, I. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain); Calderón, E. [SENER Ingeniería y Sistemas, C/ Provença 392, 5a, 08025 Barcelona (Spain); Alberro, G. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain); Balart, D. [SENER Ingeniería y Sistemas, Avda. Zugazarte 56, 48930 Las Arenas, Vizcaya (Spain); Sarrionandia-Ibarra, A. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain); Pérez, V. [SENER Ingeniería y Sistemas, Avda. Zugazarte 56, 48930 Las Arenas, Vizcaya (Spain); Ibarra, A. [EURATOM-CIEMAT Fusion Assoc., Fusion Technology Division, Av. Complutense 40, 28040 Madrid (Spain); Legarda, F. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2014-10-15

    Highlights: • Full material characterization as far as hydrogen transport properties are concern. • Quantification of permeator leaks and material degasification. • Analysis of H{sub 2} recovered by means of permeation against vacuum in different conditions. • Hydrogen recovery efficiencies determination. - Abstract: Tritium recovery in fusion reactors is one of the main goals in R and D, as a limited inventory is available and its uneconomic production. That is the reason why efficient technologies are indispensable to be developed in order to achieve fast tritium recovery and its subsequent reuse in the system for increasing its self-sufficiency. In this work a flexible tritium recovery demonstrator prototype based on permeation against vacuum concept has been designed and manufactured, as well as all necessary equipment for a Pb15.7Li loop implementation in order to test and demonstrate that an in-pipe integrated solution is possible, and at the same time, to validate the manufacturing process. Thus, efficient rates for more optimized future models could be then extrapolated. The aim of this paper is to show the different testing results that have been carried out in this research project. These results include permeation properties of the material considered for the permeator, as long as it has been manufactured with a novel technique, Selective Laser Melting. They also include vacuum tests on the permeator to quantify possible leakages and to set up and analyze the capability to generate vacuum inside the permeator, and finally, permeation tests with the prototype, in a first stage with a gas mixture of hydrogen and argon inside the loop instead of Pb15.7Li.

  4. Dromion solutions for an electron acoustic wave and its application ...

    Indian Academy of Sciences (India)

    Abstract. The nonlinear evolution of an electron acoustic wave is shown to obey the Davey–. Stewartson I equation which admits so called dromion solutions. The importance of these two dimensional localized solutions for recent satellite observations of wave structures in the day side polar cap regions is discussed and the ...

  5. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    user

    2Radiation Technology Development Division, Bhabha Atomic Research Centre (BARC), Mumbai-400085, India. Accepted 30 May, 2011. The use of electron beam to disinfect sewage water is gaining importance. The current problem on environmental health in relation to water pollution insists for the safe disposal of ...

  6. The application of a linear electron accelerator in radiation processing

    Science.gov (United States)

    Ruiying, Zhou; Binglin, Wang; Wenxiu, Chen; Yongbao, Gu; Yinfen, Zhang; Simin, Qian; Andong, Liu; Peide, Wang

    A 3-5 MeV electron beam generated by a BF-5 type linear electron accelerator has been used in some radiation processing works, such as, (1) The cross-linking technology by radiation for the polyethylene foaming processing --- the correlation between the cross-linkage and the absorbed dose, the relation between the elongation of foaming polyethylene and the dose, the relation between the size of the cavities and the gelatin rate and the optimum range of dosage for foaming have been found. (2) The research work on the fast switch thyristor irradiated by electron beam --- The relation between the absorbed dose and the life-time of minority carriers has been studied and the optimum condition for radiation processing was determined. This process is much better than the conventional gold diffusion in raising the quality and end-product rate of these devices. Besides, we have made some testing works on the hereditary mutation of plant seeds and microorganism mutation induced by electron radiation and radiation sterilization for some medical instruments and foods.

  7. Failure modes of conducting yarns in electronic-textile applications

    NARCIS (Netherlands)

    Kok, M. de; Vries, H. de; Pacheco, K.; Heck, G. van

    2015-01-01

    Integration of electronic functionalities into textiles adds to the value of textiles. It allows measuring, detecting, actuating and treating or communicating with a body or object. These added values can render the smart textiles very useful, fun, supporting, protecting or even lifesaving. It is,

  8. Application of compact electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Muramatsu, M.; Kitagawa, A.; Iwata, Y.; Ogawa, H.; Hojo, S.; Kubo, T.; Kato, Y.; Biri, S.; Fekete, E.; Yoshida, Y.; Drentje, A. G.

    The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C(4+) ions; its performance such as beam

  9. Electronics system design techniques for safety critical applications

    CERN Document Server

    Sterpone, Luca

    2008-01-01

    Addresses the development of techniques for the evaluation and the hardening of designs implemented on SRAM-based Field Programmable Gate Arrays. This title presents a design methodology solving industrial designer''s needs for implementing electronic systems using SRAM-based FPGAs in critical environments, like the space or avionic ones.

  10. Electron Beam Cured Epoxy Resin Composites for High Temperature Applications

    Science.gov (United States)

    Janke, Christopher J.; Dorsey, George F.; Havens, Stephen J.; Lopata, Vincent J.; Meador, Michael A.

    1997-01-01

    Electron beam curing of Polymer Matrix Composites (PMC's) is a nonthermal, nonautoclave curing process that has been demonstrated to be a cost effective and advantageous alternative to conventional thermal curing. Advantages of electron beam curing include: reduced manufacturing costs; significantly reduced curing times; improvements in part quality and performance; reduced environmental and health concerns; and improvement in material handling. In 1994 a Cooperative Research and Development Agreement (CRADA), sponsored by the Department of Energy Defense Programs and 10 industrial partners, was established to advance the electron beam curing of PMC technology. Over the last several years a significant amount of effort within the CRADA has been devoted to the development and optimization of resin systems and PMCs that match the performance of thermal cured composites. This highly successful materials development effort has resulted in a board family of high performance, electron beam curable cationic epoxy resin systems possessing a wide range of excellent processing and property profiles. Hundreds of resin systems, both toughened and untoughened, offering unlimited formulation and processing flexibility have been developed and evaluated in the CRADA program.

  11. Electronic properties of boron and nitrogen doped graphene nanoribbons and its application for graphene electronics

    Energy Technology Data Exchange (ETDEWEB)

    Huang Bing, E-mail: Bing.Huang@nrel.go [Department of Physics, Tsinghua University, Beijing 100084 (China)

    2011-01-24

    On the basis of density functional theory calculations, we have systematically investigated the electronic properties of armchair-edge graphene nanoribbons (GNRs) doped with boron (B) and nitrogen (N) atoms. B (N) atoms could effectively introduce holes (electrons) to GNRs and the system exhibits p- (n-) type semiconducting behavior after B (N) doping. According to the electronic structure calculations, Z-shape GNR-based field effect transistors (FETs) is constructed by selective doping with B or N atoms. Using first-principles quantum transport calculations, we demonstrate that the B-doped p-type GNR-FETs can exhibit high levels of performance, with high ON/OFF ratios and low subthreshold swing. Furthermore, the performance parameters of GNR-FETs could be controlled by the p-type semiconducting channel length.

  12. Low-rank factorization of electron integral tensors and its application in electronic structure theory

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Bo; Kowalski, Karol

    2017-03-01

    In this letter, we introduce the reverse Cuthill-McKee (RCM) algorithm, which is often used for the bandwidth reduction of sparse tensors, to transform the two-electron integral tensors to their block diagonal forms. By further applying the pivoted Cholesky decomposition (CD) on each of the diagonal blocks, we are able to represent the high-dimensional two-electron integral tensors in terms of permutation matrices and low-rank Cholesky vectors. This representation facilitates the low-rank factorization of the high-dimensional tensor contractions that are usually encountered in post-Hartree-Fock calculations. In this letter, we discuss the second-order Møller-Plesset (MP2) method and linear coupled- cluster model with doubles (L-CCD) as two simple examples to demonstrate the efficiency of the RCM-CD technique in representing two-electron integrals in a compact form.

  13. Application of ionic liquids in vacuum microwave-assisted extraction followed by macroporous resin isolation of three flavonoids rutin, hyperoside and hesperidin from Sorbus tianschanica leaves.

    Science.gov (United States)

    Gu, Huiyan; Chen, Fengli; Zhang, Qiang; Zang, Jing

    2016-03-01

    Rutin, hyperoside and hesperidin were effectively extracted from Sorbus tianschanica leaves by an ionic liquid vacuum microwave-assisted method. A series of ionic liquids with various anions and alkyl chain length of the cations were studied and the extraction was performed in [C6mim][BF4] aqueous solution. After optimization by a factorial design and response surface methodology, total extraction yield of 2.37mg/g with an error of 0.12mg/g (0.71±0.04mg/g, 1.18±0.06mg/g and 0.48±0.02 for rutin, hyperoside and hesperidin, respectively) was achieved under -0.08MPa for vacuum, 19min and 420W for microwave irradiation time and power, and 15mL/g for liquid-solid ratio. The proposed method here is more efficient and needs a shorter extraction time for rutin, hyperoside and hesperidin from S. tianschanica leaves than reference extraction techniques. In stability studies performed with standard rutin, hyperoside and hesperidin, the target analytes were stable under the optimum conditions. The proposed method had a high reproducibility and precision. In addition, separation of rutin, hyperoside and hesperidin from [C6mim][BF4] extraction solution was completed effectively by AB-8 macroporous resin adsorption and desorption process. Ionic liquid vacuum microwave-assisted extraction is a simple, rapid and efficient sample extraction technique. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. LEP Vacuum Chamber

    CERN Multimedia

    1983-01-01

    This is a cut-out of a LEP vacuum chamber for dipole magnets showing the beam channel and the pumping channel with the getter (NEG) strip and its insulating supports. A water pipe connected to the cooling channel can also be seen at the back.The lead radiation shield lining is also shown. See also 8305563X.

  15. The vacuum strikes back

    CERN Multimedia

    2007-01-01

    "Modern physics has shown that the vacuum, previously thought of as a stated of total nothingness, is really a seething background of virtual particles springing in and out of eixstence until they can seize enough energy to materialize as "real" particles." (1,5 page)

  16. LEP vacuum chamber, prototype

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  17. ISR vacuum system

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    Some of the most important components of the vacuum system are shown. At the left, the rectangular box is a sputter-ion pump inside its bake-out oven. The assembly in the centre includes a sector valve, three roughing valves, a turbomolecular pump, a rotary backing pump and auxiliary equipment. At the right, the small elbow houses a Bayard-

  18. A Survey on the Reliability of Power Electronics in Electro-Mobility Applications

    DEFF Research Database (Denmark)

    Gadalla, Brwene Salah Abdelkarim; Schaltz, Erik; Blaabjerg, Frede

    2015-01-01

    Reliability is an important issue in the field of power electronics since most of the electrical energy is today processed by power electronics. In most of the electro-mobility applications, e.g. electric and hybridelectric vehicles, power electronic are commonly used in very harsh environment...... and extending the service lifetime as well. Research within power electronics is of high interest as it has an important impact in the industry of the electro-mobility applications. According to the aforementioned explanations, this paper will provide an overview of the common factors (thermal cycles, power...... cycles, vibrations, voltage stress and current ripple stress) affecting the reliability of power electronics in electromobility applications. Also, the researchers perspective is summarized from 2001 to 2015....

  19. Mobile agent application and integration in electronic anamnesis system.

    Science.gov (United States)

    Liu, Chia-Hui; Chung, Yu-Fang; Chen, Tzer-Shyong; Wang, Sheng-De

    2012-06-01

    Electronic anamnesis is to transform ordinary paper trails to digitally formatted health records, which include the patient's general information, health status, and follow-ups on chronic diseases. Its main purpose is to let the records could be stored for a longer period of time and could be shared easily across departments and hospitals. Which means hospital management could use less resource on maintaining ever-growing database and reduce redundancy, so less money would be spent for managing the health records. In the foreseeable future, building up a comprehensive and integrated medical information system is a must, because it is critical to hospital resource integration and quality improvement. If mobile agent technology is adopted in the electronic anamnesis system, it would help the hospitals to make the medical practices more efficiently and conveniently. Nonetheless, most of the hospitals today are still using paper-based health records to manage the medical information. The reason why the institutions continue using traditional practices to manage the records is because there is no well-trusted and reliable electronic anamnesis system existing and accepted by both institutions and patients. The threat of privacy invasion is one of the biggest concerns when the topic of electronic anamnesis is brought up, because the security threats drag us back from using such a system. So, the medical service quality is difficult to be improved substantially. In this case, we have come up a theory to remove such security threats and make electronic anamnesis more appealing for use. Our theory is to integrate the mobile agent technology with the backbone of electronic anamnesis to construct a hierarchical access control system to retrieve the corresponding information based upon the permission classes. The system would create a classification for permission among the users inside the medical institution. Under this framework, permission control center would distribute an

  20. Two-Dimensional Electronic Spectroscopies for Probing Electronic Structure and Charge Transfer: Applications to Photosystem II

    Energy Technology Data Exchange (ETDEWEB)

    Ogilvie, Jennifer P. [Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Physics

    2016-11-22

    Photosystem II (PSII) is the only known natural enzyme that uses solar energy to split water, making the elucidation of its design principles critical for our fundamental understanding of photosynthesis and for our ability to mimic PSII’s remarkable properties. This report discusses progress towards addressing key open questions about the PSII RC. It describes new spectroscopic methods that were developed to answer these questions, and summarizes the outcomes of applying these methods to study the PSII RC. Using 2D electronic spectroscopy and 2D electronic Stark spectroscopy, models for the PSII RC were tested and refined. Work is ongoing to use the collected data to elucidate the charge separation mechanism in the PSII RC. Coherent dynamics were also observed in the PSII RC for the first time. Through extensive characterization and modeling we have assigned these coherences as vibronic in nature, and believe that they reflect resonances between key vibrational pigment modes and electronic energy gaps that may facilitate charge separation. Work is ongoing to definitively test the functional relevance of electronic-vibrational resonances.

  1. Inkjet printing and low temperature sintering for organic electronic applications

    NARCIS (Netherlands)

    Wünscher, S.; Teichler, A.; Perelaer, J.; Abbel, R.J.; Schubert, U.S.

    2012-01-01

    In recent years, inkjet printing is increasingly used as a flexible and digital patterning technique in order to deposit functional materials for the manufacturing of microelectronic applications, including radio frequency identification (RFID) tags, organic photovoltaics (OPV), organic light

  2. Furnace brazing under partial vacuum

    Science.gov (United States)

    Mckown, R. D.

    1979-01-01

    Brazing furnace utilizing partial-vacuum technique reduces tooling requirements and produces better bond. Benefit in that partial vacuum helps to dissociate metal oxides that inhibit metal flow and eliminates heavy tooling required to hold parts together during brazing.

  3. Tritium handling in vacuum systems

    Energy Technology Data Exchange (ETDEWEB)

    Gill, J.T. [Monsanto Research Corp., Miamisburg, OH (United States). Mound Facility; Coffin, D.O. [Los Alamos National Lab., NM (United States)

    1986-10-01

    This report provides a course in Tritium handling in vacuum systems. Topics presented are: Properties of Tritium; Tritium compatibility of materials; Tritium-compatible vacuum equipment; and Tritium waste treatment.

  4. New Leverage for Increasing Tax Revenues in Turkey: Traditional Tax Applications Supported by Electronic Tax Audits

    National Research Council Canada - National Science Library

    Ozge Onkan

    2016-01-01

    In this study, it is examined for the period 2000- 2015 in Turkey that increasing the electronic applications regarding tax audits had the effects on the required amount of tax levied as a result of tax audits...

  5. Artificial Intelligence Tool and Electronic Systems Used to Develop Optical Applications

    OpenAIRE

    Tecpoyotl-Torres, Margarita; Ochoa, Alberto; Escobedo-Alatorre, Jesus; Basurto-Pensado, Miguel; Garcia-Arias, Arturo; Morales-Valladares, Jessica

    2010-01-01

    This work confirms the relevance of the automation in optics applications. For the realization of all the prototype, it was required of a multidisciplinary team, involving basically programming, electronics and optics knowledge.

  6. Electronic absorption spectra and geometry of organic molecules an application of molecular orbital theory

    CERN Document Server

    Suzuki, Hiroshi

    1967-01-01

    Electronic Absorption Spectra and Geometry of Organic Molecules: An Application of Molecular Orbital Theory focuses on electronic absorption spectra of organic compounds and molecules. The book begins with the discussions on molecular spectra, electronic absorption spectra of organic compounds, and practical measures of absorption intensity. The text also focuses on molecular orbital theory and group theory. Molecular state functions; fundamental postulates of quantum theory; representation of symmetry groups; and symmetry operations and symmetry groups are described. The book also dis

  7. Application of the maximum entropy method to electron density determination

    Energy Technology Data Exchange (ETDEWEB)

    Wei Wendo

    1985-12-01

    The principle of maximum entropy is adopted to derive a procedure for obtaining the electron density distribution in crystals from incomplete X-ray diffraction data. This method was applied to cementite and the result proved to be better than the conventional Fourier inversion in resolution as well as in the absence of ripples. The potential advantages of this method are: (1) the amount of subjective judgment imposed on unavailable data is significantly limited, and (2) the result of this method is consistent with the known information and maximally noncommittal with regard to the unknowns. It is shown that the method is especially well suited to the problem of the determination of a high-resolution electron density map from insufficient experimental data. (orig.).

  8. Electronic Healthcare Records: an essential part of Health Telematics Applications.

    Science.gov (United States)

    Engelbrecht, R; Hildebrand, C; Moser, W

    2000-01-01

    A healthcare record should ideally be a repository of data, describing a person's health and how it is being supported; and not, as it is now, describing a person's diseases and treatment only. The healthcare record is the basis for monitoring and decisions. Therefore it should be open and available to all authorized health professionals and to the patient. To make this easier is one of the major advantages of electronic healthcare records (EHCR). The computer-based patient record could make major contributions to improving the healthcare system. This is the motivation to initiatives, projects and routine implementations of electronic patient records. The European Union and national initiatives have put major efforts into the support of this main field of medical information processing.

  9. Nanobiotechnology in energy, environment and electronics methods and applications

    CERN Document Server

    Nicolini, Claudio

    2015-01-01

    Introduction: Present Challenges and Future Solutions via Nanotechnology for Electronics, Environment and Energy; Claudio NicoliniPart A: MethodsInfluence of Chromosome Translocation on Yeast Life Span: Implications for Long-Term Industrial Biofermentation; Jason Sims, Dmitri Nikitin, and Carlo V. BruschiPulsed Power Nanotechnologies for Disintegration and Breaking Up of Refractory Precious Metals Ores; Valentin A. Chanturiya and Igor Zh. BuninModeling of Software Sensors in Bioprocess; Luca Belmonte and Claudio NicoliniN

  10. Research and application of electron accelerator in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhan Wenlong; Liu Zhenghao [Chinese Academy of Sciences, Institute of Modern Physics, Lanzhou (China)

    2003-02-01

    There are more than 30 product lines of irradiation cross-linking wire and cable and shrinkable tube by EB in Chinese industry. Total of 3,000 KW power of EB, in which 40% coming from home made accelerator. Recently, about 450 KW electron accelerator is being manufactured and used in protection of environment that is removal of SO{sub 2} and NO{sub x} from flue gas. (author)

  11. Stretchable Electronic Platform for Soft and Smart Contact Lens Applications

    OpenAIRE

    Vasquez Quintero, Andrés Felipe; Verplancke, Rik; De Smet, Herbert; Vanfleteren, Jan

    2017-01-01

    A stretchable platform with spherical-shaped electronics based on thermo- plastic polyurethane (TPU) is introduced for soft smart contact lenses. The low glass transition temperature of TPU, its relatively low hardness, and its proven biocompatibility (i.e., protection of exterior body wounds) fulfill the essential requirements for eye wearable devices. These requirements include optical transparency, conformal fitting, and flexibility comparable with soft contact lense...

  12. Application of Hybrid IC's to the Automotive Electronics Market in Europe

    OpenAIRE

    von Roda, Eckart

    1981-01-01

    In the last few years hybrids have been increasingly used in automotive electronics in Europe. With examples from the BOSCH and BLAUPUNKT production range their application in regulators, breakerless ignition modules, electronically-controlled fuel injection systems and car radios is illustrated. The elements and techniques used to assemble the hybrids, and the advantages which can be gained are discussed.

  13. 78 FR 19182 - Electronic Filing of Import Inspection Applications for Meat, Poultry, and Egg Products...

    Science.gov (United States)

    2013-03-29

    ... Food Safety and Inspection Service Electronic Filing of Import Inspection Applications for Meat... Listserv, a free electronic mail subscription service for industry, trade groups, consumer interest groups...: Food Safety and Inspection Service, USDA. ACTION: Notice and request for comments. SUMMARY: The Food...

  14. Future applications of electronic-nose technologies in healthcare and biomedicine

    Science.gov (United States)

    Alphus D. Wilson

    2011-01-01

    The development and utilization of many new electronic-nose (e-nose) applications in the healthcare and biomedical fields have continued to rapidly accelerate over the past 20 years. Innovative e-nose technologies are providing unique solutions to a diversity of complex problems in biomedicine that are now coming to fruition. A wide range of electronic-nose instrument...

  15. A Study on the Training Mode of Electronic Application-Oriented Undergraduate with Industry Needs

    Science.gov (United States)

    Wang, Zhonghua; Cheng, Lifang; Wang, Hao

    2017-01-01

    Electronic industry is an economic pillar in China. Due to the Moore's Law, the industry requires continuous development and innovation. In order to achieve these goals, the cultivation of electronic application-oriented undergraduate is essential. However, at current, the innovative educational concepts and teaching methods are lagging behind so…

  16. Application of models for exchange of electronic documents in complex administrative services

    Science.gov (United States)

    Glavev, Victor

    2015-11-01

    The report presents application of models for exchange of electronic documents between different administrations in government and business sectors. It shows the benefits of implementing electronic exchange of documents between different local offices of one administration in government sector such as a municipality and the way it is useful for implementing complex administrative services.

  17. 76 FR 70651 - Fee for Filing a Patent Application Other Than by the Electronic Filing System

    Science.gov (United States)

    2011-11-15

    ... the Electronic Filing System AGENCY: United States Patent and Trademark Office, Commerce. ACTION... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF COMMERCE... for a design, plant, or provisional application, that is not filed by electronic means as prescribed...

  18. Applications of aberration corrected scanning transmission electron microscopy and electron energy loss spectroscopy to thin oxide films and interfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Varela del Arco, Maria [ORNL; Gazquez Alabart, Jaume [ORNL; Lupini, Andrew R [ORNL; Luck, Julia T [ORNL; Torija, Maria [University of Minnesota; Sharma, M [University of Minnesota; Leighton, chris [University of Minnesota; Biegalski, Michael D [ORNL; Christen, Hans M [ORNL; Murfitt, Matt [Nion Co; Dellby, Niklas [ORNL; Krivanek, Ondrej [ORNL; Pennycook, Stephen J [ORNL

    2010-01-01

    Aberration correction in the scanning transmission electron microscope allows spatial resolutions of the order of one ngstr m to be routinely achieved. When combined with electron energy loss spectroscopy, it is possible to simultaneously map the structure, the chemistry and even the electronic properties of materials in one single experiment. Here we will apply these techniques to the characterization of thin films and interfaces based on complex oxides with the perovskite structure. The relatively large lattice parameter of these materials combined with the fact that most of them have absorption edges within the reach of the spectrometer optics makes these materials ideal for these experiments. We will show how it is possible to map the chemistry of interfaces atomic plane by atomic plane, including light element imaging such as O. Applications to cobaltite and titanate thin films will be described.

  19. Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron-electron interactions, application to graphene

    Science.gov (United States)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2017-07-01

    Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron-electron (e-e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e-e interactions. This required adapting the treatment of e-e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

  20. Electronic aroma detection technology for forensic and law enforcement applications

    Energy Technology Data Exchange (ETDEWEB)

    Barshick, S.-A.; Griest, W.H.; Vass, A.A.

    1996-12-31

    A major problem hindering criminal investigations is the lack of appropriate tools for proper crime scene investigations. Often locating important pieces of evidence means relying on the ability of trained detection canines. Development of analytical technology to uncover and analyze evidence, potentially at the scene, could serve to expedite criminal investigations, searches, and court proceedings. To address this problem, a new technology based on gas sensor arrays was investigated for its applicability to forensic and law enforcement problems. The technology employs an array of sensors that respond to volatile chemical components yielding a characteristic `fingerprint` pattern representative of the vapor- phase composition of a sample. Sample aromas can be analyzed and identified using artificial neural networks that are trained on known aroma patterns. Several candidate applications based on known technological needs of the forensic and law enforcement communities have been investigated. These applications have included the detection of aromas emanating from cadavers to aid in determining time since death, drug detection for deterring the manufacture, sale, and use of drugs of abuse, and the analysis of fire debris for accelerant identification. The results to date for these applications have been extremely promising and demonstrate the potential applicability of this technology for forensic use.

  1. Electron beam mediated synthesis of grapheme-based nano hybrids for energy storage applications

    Energy Technology Data Exchange (ETDEWEB)

    Paek, Seungmin [Kyungpook National Univ., Taegu (Korea, Republic of)

    2013-07-01

    A new synthetic strategy for preparing nanoporous materials was developed using an electron beam irradiation technique. Graphene-based nanosheets were hybridized with nickel nanoparticles to fabricate flexible delaminated structures for energy storage applications. To elucidate the influence of an electron beam irradiation, the resulting hybrids were irradiated by an electron beam with 100-250 kGy doses under atmospheric conditions. According to X-ray diffraction and transmission electron microscopic analysis, graphene nanosheets were randomly reassembled with nickel nanoparticles without any self-restacking into the layered phase. X-ray absorption spectroscopic analysis revealed that nickel particles in the hybrid materials maintained their nanosized nature even after an electron beam irradiation. The energy storage performances of electron beam-irradiated samples were superior to those of starting materials, highlighting the effectiveness of an electron beam irradiation.

  2. New Materials for Vacuum Chambers in High Energy Physics

    CERN Document Server

    Garion, Cédric

    2014-01-01

    Vacuum chambers must fulfil ultra-high vacuum requirements while withstanding thermo-mechanical loads. This is particularly true in high energy particle accelerator where interactions of particles with matter may induce thermal load, material activation, background… The choice of the material of the vacuum chamber is crucial for the final application. Metals such as stainless steel, copper and aluminium are usually used. Even with outstanding mechanical and physical properties, beryllium is used for very specific applications because of its cost and toxicity.Ceramics such as alumina are usually used for fast magnet vacuum chambers. With the next generation of high energy physics accelerator generation such as CLIC and TLEP, the problematic of high cyclic thermal load induced by synchrotron radiation is raised. This paper aims at defining some figures of merit of different materials with respect to several load scenarios and presents briefly their vacuum compatibility.

  3. Detailed Modeling of Flat Plate Solar Collector with Vacuum Glazing

    Directory of Open Access Journals (Sweden)

    Viacheslav Shemelin

    2017-01-01

    Full Text Available A theoretical analysis of flat plate solar collectors with a vacuum glazing is presented. Different configurations of the collector have been investigated by a detailed theoretical model based on a combined external and internal energy balance of the absorber. Performance characteristics for vacuum flat plate collector alternatives have been derived. Subsequently, annual energy gains have been evaluated for a selected variant and compared with state-of-the-art vacuum tube collectors. The results of modeling indicate that, in the case of using advanced vacuum glazing with optimized low-emissivity coating (emissivity 0.20, solar transmittance 0.85, it is possible to achieve efficiency parameters similar to or even better than vacuum tube collectors. The design presented in this paper can be considered promising for the extension of the applicability range of FPC and could be used in applications, which require low-to-medium temperature level.

  4. Vacuum Attachment for XRF Scanner

    Science.gov (United States)

    Schramm, Harry F.; Kaiser, Bruce

    2005-01-01

    Vacuum apparatuses have been developed for increasing the range of elements that can be identified by use of x-ray fluorescent (XRF) scanners of the type mentioned in the two immediately preceding articles. As a consequence of the underlying physical principles, in the presence of air, such an XRF scanner is limited to analysis of chlorine and elements of greater atomic number. When the XRF scanner is operated in a vacuum, it extends the range of analysis to lower atomic numbers - even as far as aluminum and sodium. Hence, more elements will be available for use in XRF labeling of objects as discussed in the two preceding articles. The added benefits of the extended capabilities also have other uses for NASA. Detection of elements of low atomic number is of high interest to the aerospace community. High-strength aluminum alloys will be easily analyzed for composition. Silicon, a major contaminant in certain processes, will be detectable before the process is begun, possibly eliminating weld or adhesion problems. Exotic alloys will be evaluated for composition prior to being placed in service where lives depend on them. And in the less glamorous applications, such as bolts and fasteners, substandard products and counterfeit items will be evaluated at the receiving function and never allowed to enter the operation

  5. Low-Cost, Rugged High-Vacuum System

    Science.gov (United States)

    Sorensen, Paul; Kline-Schoder, Robert

    2012-01-01

    A need exists for miniaturized, rugged, low-cost high-vacuum systems. Recent advances in sensor technology have led to the development of very small mass spectrometer detectors as well as other analytical instruments such as scanning electron microscopes. However, the vacuum systems to support these sensors remain large, heavy, and power-hungry. To meet this need, a miniaturized vacuum system was developed based on a very small, rugged, and inexpensive-to-manufacture molecular drag pump (MDP). The MDP is enabled by a miniature, very-high-speed (200,000 rpm), rugged, low-power, brushless DC motor optimized for wide temperature operation and long life. The key advantages of the pump are reduced cost and improved ruggedness compared to other mechanical hig-hvacuum pumps. The machining of the rotor and stators is very simple compared to that necessary to fabricate rotor and stator blades for other pump designs. Also, the symmetry of the rotor is such that dynamic balancing of the rotor will likely not be necessary. Finally, the number of parts in the unit is cut by nearly a factor of three over competing designs. The new pump forms the heart of a complete vacuum system optimized to support analytical instruments in terrestrial applications and on spacecraft and planetary landers. The MDP achieves high vacuum coupled to a ruggedized diaphragm rough pump. Instead of the relatively complicated rotor and stator blades used in turbomolecular pumps, the rotor in the MDP consists of a simple, smooth cylinder of aluminum. This will turn at approximately 200,000 rpm inside an outer stator housing. The pump stator comprises a cylindrical aluminum housing with one or more specially designed grooves that serve as flow channels. To minimize the length of the pump, the gas is forced down the flow channels of the outer stator to the base of the pump. The gas is then turned and pulled toward the top through a second set of channels cut into an inner stator housing that surrounds the

  6. Analysis and application of analog electronic circuits to biomedical instrumentation

    CERN Document Server

    Northrop, Robert B

    2012-01-01

    All chapters include an introduction and chapter summary.Sources and Properties of Biomedical SignalsSources of Endogenous Bioelectric SignalsNerve Action PotentialsMuscle Action PotentialsThe ElectrocardiogramOther BiopotentialsElectrical Properties of BioelectrodesExogenous Bioelectric SignalsProperties and Models of Semiconductor Devices Used in Analog Electronic Systemspn Junction DiodesMidfrequency Models for BJT BehaviorMidfrequency Models for Field-Effect TransistorsHigh-Frequency Models for Transistors and Simple Transistor AmplifiersPhotons, Photodiodes, Photoconductors, LEDs, and Las

  7. Application of an Electronic Medical Record in Space Medicine

    Science.gov (United States)

    McGinnis, Patrick J.

    2000-01-01

    Electronic Medical Records (EMR) have been emerging over the past decade. Today, they are replacing the paper chart in clinics throughout the nation. Approximately three years ago, the NASA-JSC Flight Medicine Clinic initiated an assessment of the EMRs available on the market. This assessment included comparing these products with the particular scope of practice at JSC. In 1998, the Logician EMR from Medicalogic was selected for the JSC Flight Medicine Clinic. This presentation reviews the process of selection and implementation of the EMR into the unique practice of aerospace medicine at JSC.

  8. Electronic recording of holograms with applications to holographic displays

    Science.gov (United States)

    Claspy, P. C.; Merat, F. L.

    1979-01-01

    The paper describes an electronic heterodyne recording which uses electrooptic modulation to introduce a sinusoidal phase shift between the object and reference wave. The resulting temporally modulated holographic interference pattern is scanned by a commercial image dissector camera, and the rejection of the self-interference terms is accomplished by heterodyne detection at the camera output. The electrical signal representing this processed hologram can then be used to modify the properties of a liquid crystal light valve or a similar device. Such display devices transform the displayed interference pattern into a phase modulated wave front rendering a three-dimensional image.

  9. Electronics speckle interferometry applications for NDE of spacecraft structural components

    Science.gov (United States)

    Rao, M. V.; Samuel, R.; Ananthan, A.; Dasgupta, S.; Nair, P. S.

    2008-09-01

    The spacecraft components viz., central cylinder, deck plates, solar panel substrates, antenna reflectors are made of aluminium/composite honeycomb sandwich construction. Detection of these defects spacecraft structural components is important to assess the integrity of the spacecraft structure. Electronic Speckle Interferometry (ESI) techniques identify the defects as anomalous regions in the interferometric fringe patterns of the specklegram while the component is suitably stressed to give rise to differential displacement/strain around the defective region. Calibration studies, different phase shifting methods associated with ESI and the development of a prototype Twin Head ESSI System (THESSIS) and its use for the NDE of a typical satellite structural component are presented.

  10. Quantum Monte Carlo for electronic structure: Recent developments and applications

    Energy Technology Data Exchange (ETDEWEB)

    Rodriquez, Maria Milagos Soto [Lawrence Berkeley Lab. and Univ. of California, Berkeley, CA (United States). Dept. of Chemistry

    1995-04-01

    Quantum Monte Carlo (QMC) methods have been found to give excellent results when applied to chemical systems. The main goal of the present work is to use QMC to perform electronic structure calculations. In QMC, a Monte Carlo simulation is used to solve the Schroedinger equation, taking advantage of its analogy to a classical diffusion process with branching. In the present work the author focuses on how to extend the usefulness of QMC to more meaningful molecular systems. This study is aimed at questions concerning polyatomic and large atomic number systems. The accuracy of the solution obtained is determined by the accuracy of the trial wave function`s nodal structure. Efforts in the group have given great emphasis to finding optimized wave functions for the QMC calculations. Little work had been done by systematically looking at a family of systems to see how the best wave functions evolve with system size. In this work the author presents a study of trial wave functions for C, CH, C2H and C2H2. The goal is to study how to build wave functions for larger systems by accumulating knowledge from the wave functions of its fragments as well as gaining some knowledge on the usefulness of multi-reference wave functions. In a MC calculation of a heavy atom, for reasonable time steps most moves for core electrons are rejected. For this reason true equilibration is rarely achieved. A method proposed by Batrouni and Reynolds modifies the way the simulation is performed without altering the final steady-state solution. It introduces an acceleration matrix chosen so that all coordinates (i.e., of core and valence electrons) propagate at comparable speeds. A study of the results obtained using their proposed matrix suggests that it may not be the optimum choice. In this work the author has found that the desired mixing of coordinates between core and valence electrons is not achieved when using this matrix. A bibliography of 175 references is

  11. Efficacy of Gaseous Ozone Application during Vacuum Cooling against Escherichia coli O157:H7 on Spinach Leaves as Influenced by Bacterium Population Size.

    Science.gov (United States)

    Yesil, Mustafa; Kasler, David R; Huang, En; Yousef, Ahmed E

    2017-07-01

    Foodborne disease outbreaks associated with the consumption of fresh produce pose a threat to public health, decrease consumer confidence in minimally processed foods, and negatively impact the sales of these commodities. The aim of the study was to determine the influence of population size of inoculated pathogen on its inactivation by gaseous ozone treatment during vacuum cooling. Spinach leaves were spot inoculated with Escherichia coli O157:H7 at approximate initial populations of 108, 107, and 105 CFU/g. Inoculated leaves were vacuum cooled (28.5 inHg; 4°C) in a custom-made vessel and then were subjected to a gaseous ozone treatment under the following conditions: 1.5 g of ozone per kg of gas mixture, vessel pressure at 10 lb/in2 gauge, 94 to 98% relative humidity, and 30 min of holding time at 9°C. Treatment of the leaves, having the aforementioned inocula, decreased E. coli populations by 0.2, 2.1, and 2.8 log CFU/g, respectively, compared with the inoculated untreated controls. Additionally, spinach leaves were inoculated at 1.4 × 103 CFU/g, which approximates natural contamination level, and the small populations remaining after ozone treatment were quantified using the most-probable-number (MPN) method. Vacuum and ozone sequential treatment decreased this E. coli O157:H7 population to ozone is effective against pathogen loads comparable to those found in naturally contaminated fresh produce, but efficacy decreases as inoculum level increases.

  12. Investigation of Heat Sink Efficiency for Electronic Component Cooling Applications

    DEFF Research Database (Denmark)

    Staliulionis, Ž.; Zhang, Zhe; Pittini, Riccardo

    2014-01-01

    of relatively simple heat sink application is performed using modeling based on finite element method, and also the potential of such analysis was demonstrated by real-world measurements and comparing obtained results. Thermal modeling was accomplished using finite element analysis software COMSOL and thermo...

  13. Beam dynamics performances and applications of a low-energy electron-beam magnetic bunch compressor

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, C. R.; Piot, P.; Carlsten, B. E.; Church, M.

    2013-08-01

    Many front-end applications of electron linear accelerators rely on the production of temporally compressed bunches. The shortening of electron bunches is often realized with magnetic bunch compressors located in high-energy sections of accelerators. Magnetic compression is subject to collective effects including space charge and self interaction via coherent synchrotron radiation. In this paper we explore the application of magnetic compression to low-energy (~40MeV), high-charge (nC) electron bunches with low normalized transverse emittances (<5@mm).

  14. LHC Vacuum Upgrade during LS1

    CERN Document Server

    Jimenez, J M; Chiggiato, P; Cruikshank, P; Gallilee, M; Garion, C; Gomes, P

    2012-01-01

    The last two years of LHC operation have highlighted concerns on the levels of the dynamic vacuum in the long straight sections in presence of high intensity beams. The analysis of the existing data has shown relationship between pressures spikes and beam screen temperature oscillations or micro-sparking in the RF fingers of the bellows on one side and coincidence of pressure bumps with stimulated desorption by electron cloud, beam losses and/or thermal out gassing stimulated by higher order modes (HOM) losses. The electron cloud mitigation solutions will be adapted to the different configurations: cold/warm transitions, non-coated surfaces in direct view of beams, photoelectrons, etc. All scenarios will be presented together with their efficiencies. Additional pumping and reengineering of components will reduce the sensitivity of the vacuum system to beam losses or HOM inducing out gassing. The expected margin at nominal intensity and energy resulting from these consolidations will be summarized. Finally, th...

  15. Particle emission characteristics of filter-equipped vacuum cleaners.

    Science.gov (United States)

    Trakumas, S; Willeke, K; Grinshpun, S A; Reponen, T; Mainelis, G; Friedman, W

    2001-01-01

    Industrial vacuum cleaners with final high-efficiency particulate air (HEPA) filters traditionally have been used for cleanup operations in which all of the nozzle-entrained dust must be collected with high efficiency, for example, after lead-based paint abatement in homes. In this study household vacuum cleaners ranging from $70 to $650 and an industrial vacuum cleaner costing more than $1400 were evaluated relative to their collection efficiency immediately after installing new primary dust collectors in them. Using newly developed testing technology, some of the low-cost household vacuum cleaners equipped with a final HEPA filter were found to have initial overall filtration efficiencies comparable to those of industrial vacuum cleaners equipped with a final HEPA filter. The household vacuum cleaners equipped with a final HEPA filter efficiently collect about 100% of the dry dust entrained by the nozzle. For extensive cleaning efforts and for vacuum cleaning of wet surfaces, however, industrial vacuum cleaners may have an advantage, including ruggedness and greater loading capacity. The methods and findings of this study are applicable to field evaluations of vacuum cleaners.

  16. Thermodynamic modelling of phase equilibrium in system Ti-B-Si-C, synthesis and phases composition of borides and carbides layers on titanic alloyVT-1 at electron beam treatment in vacuum

    Science.gov (United States)

    Smirnyagina, N. N.; Khaltanova, V. M.; Lapina, A. E.; Dasheev, D. E.

    2017-01-01

    Composite layers on the basis of carbides and borides the titan and silicon on titanic alloy VT-1 are generated at diffused saturation in vacuum. Formation in a composite of MAX phase Ti3SiC2 is shown. Thermodynamic research of phase equilibrium in systems Ti-Si-C and Ti-B-C in the conditions of high vacuum is executed. The thermodynamics, formation mechanisms of superfirm layers borides and carbides of the titan and silicon are investigated.

  17. Electron microscopy by specimen design: application to strain measurements.

    Science.gov (United States)

    Cherkashin, Nikolay; Denneulin, Thibaud; Hÿtch, Martin J

    2017-09-29

    A bewildering number of techniques have been developed for transmission electron microscopy (TEM), involving the use of ever more complex combinations of lens configurations, apertures and detector geometries. In parallel, the developments in the field of ion beam instruments have modernized sample preparation and enabled the preparation of various types of materials. However, the desired final specimen geometry is always almost the same: a thin foil of uniform thickness. Here we will show that judicious design of specimen geometry can make all the difference and that experiments can be carried out on the most basic electron microscope and in the usual imaging modes. We propose two sample preparation methods that allow the formation of controlled moiré patterns for general monocrystalline structures in cross-section and at specific sites. We developed moiré image treatment algorithms using an absolute correction of projection lens distortions of a TEM that allows strain measurements and mapping with a nanometer resolution and 10-4 precision. Imaging and diffraction techniques in other fields may in turn benefit from this technique in perspective.

  18. Epidermal electronics for electromyography: An application to swallowing therapy.

    Science.gov (United States)

    Constantinescu, Gabriela; Jeong, Jae-Woong; Li, Xinda; Scott, Dylan K; Jang, Kyung-In; Chung, Hyun-Joong; Rogers, John A; Rieger, Jana

    2016-08-01

    Head and neck cancer treatment alters the anatomy and physiology of patients. Resulting swallowing difficulties can lead to serious health concerns. Surface electromyography (sEMG) is used as an adjuvant to swallowing therapy exercises. sEMG signal collected from the area under the chin provides visual biofeedback from muscle contractions and is used to help patients perform exercises correctly. However, conventional sEMG adhesive pads are relatively thick and difficult to effectively adhere to a patient's altered chin anatomy, potentially leading to poor signal acquisition in this population. Here, the emerging technology of epidermal electronics is introduced, where ultra-thin geometry allows for close contouring of the chin. The two objectives of this study were to (1) assess the potential of epidermal electronics technology for use with swallowing therapy and (2) assess the significance of the reference electrode placement. This study showed comparative signals between the new epidermal sEMG patch and the conventional adhesive patches used by clinicians. Furthermore, an integrated reference yielded optimal signal for clinical use; this configuration was more robust to head movements than when an external reference was used. Improvements for future iterations of epidermal sEMG patches specific to day-to-day clinical use are suggested. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Portable X-Band Linear Electron Accelerators for Radiographic Applications

    CERN Document Server

    Saverskiy, Aleksandr J; Hernandez, Michael; Mishin, Andrey V; Skowbo, Dave

    2005-01-01

    The MINAC series portable linear electron accelerator systems designed and manufactured at American Science and Engineering, Inc. High Energy Systems Division (AS&E HESD) are discussed in this paper. Each system can be configured as either an X-ray or electron beam source. The powerful 4 MeV and 6 MeV linacs powered by a 1,5 MW magnetron permit operation in a dose rate range from 100 R/min at 80 cm to 600 R/min at 80 cm. Each MINAC is a self-contained source with radiation leakage outside of the X-ray head less than 0,1% of the maximum dose. Along with these systems a 1 MeV ultra compact MINAC has been successfully tested. The unit is available with radiation leakage less then 0.01% and permits producing X-ray beam in an energy range (1…2) MeV at a high output dose rate. Design and experimental parameters are presented. The common and system specific features are also discussed.

  20. Electronic system for floor surface type detection in robotics applications

    Science.gov (United States)

    Tarapata, Grzegorz; Paczesny, Daniel; Tarasiuk, Łukasz

    2016-11-01

    The paper reports a recognizing method base on ultrasonic transducers utilized for the surface types detection. Ultra-sonic signal is transmitted toward the examined substrate, then reflected and scattered signal goes back to another ultra-sonic receiver. Thee measuring signal is generated by a piezo-electric transducer located at specified distance from the tested substrate. The detector is a second piezo-electric transducer located next to the transmitter. Depending on thee type of substrate which is exposed by an ultrasonic wave, the signal is partially absorbed inn the material, diffused and reflected towards the receiver. To measure the level of received signal, the dedicated electronic circuit was design and implemented in the presented systems. Such system was designed too recognize two types of floor surface: solid (like concrete, ceramic stiles, wood) and soft (carpets, floor coverings). The method will be applied in electronic detection system dedicated to autonomous cleaning robots due to selection of appropriate cleaning method. This work presents the concept of ultrasonic signals utilization, the design of both the measurement system and the measuring stand and as well number of wide tests results which validates correctness of applied ultrasonic method.

  1. Reduced density matrix hybrid approach: Application to electronic energy transfer

    Energy Technology Data Exchange (ETDEWEB)

    Berkelbach, Timothy C.; Reichman, David R. [Department of Chemistry, Columbia University, 3000 Broadway, New York, New York 10027 (United States); Markland, Thomas E. [Department of Chemistry, Stanford University, 333 Campus Drive, Stanford, California 94305 (United States)

    2012-02-28

    Electronic energy transfer in the condensed phase, such as that occurring in photosynthetic complexes, frequently occurs in regimes where the energy scales of the system and environment are similar. This situation provides a challenge to theoretical investigation since most approaches are accurate only when a certain energetic parameter is small compared to others in the problem. Here we show that in these difficult regimes, the Ehrenfest approach provides a good starting point for a dynamical description of the energy transfer process due to its ability to accurately treat coupling to slow environmental modes. To further improve on the accuracy of the Ehrenfest approach, we use our reduced density matrix hybrid framework to treat the faster environmental modes quantum mechanically, at the level of a perturbative master equation. This combined approach is shown to provide an efficient and quantitative description of electronic energy transfer in a model dimer and the Fenna-Matthews-Olson complex and is used to investigate the effect of environmental preparation on the resulting dynamics.

  2. Nonperturbative QED vacuum birefringence

    Science.gov (United States)

    Denisov, V. I.; Dolgaya, E. E.; Sokolov, V. A.

    2017-05-01

    In this paper we represent nonperturbative calculation for one-loop Quantum Electrodynamics (QED) vacuum birefringence in presence of strong magnetic field. The dispersion relations for electromagnetic wave propagating in strong magnetic field point to retention of vacuum birefringence even in case when the field strength greatly exceeds Sauter-Schwinger limit. This gives a possibility to extend some predictions of perturbative QED such as electromagnetic waves delay in pulsars neighbourhood or wave polarization state changing (tested in PVLAS) to arbitrary magnetic field values. Such expansion is especially important in astrophysics because magnetic fields of some pulsars and magnetars greatly exceed quantum magnetic field limit, so the estimates of perturbative QED effects in this case require clarification.

  3. Vacuum distillation device

    Energy Technology Data Exchange (ETDEWEB)

    Hamer, J.A.; Burg, C.J. Van Der; Kanbier, D.; Heijden, P. Van Der.

    1990-09-18

    This invention relates to a vacuum distillation device comprising a vacuum distillation column, a furnace provided with a heat exchange tube, and a connecting conduit between the column and the heat exchange tube. Such a device is used to fractionate a hydrocarbon-containing feed sometimes referred to as long residue. An object of this invention is to provide a vacuum distillation device which allows vaporization of a major part of the feed upstream of the column inlet. To this end, the device according to the invention comprises a vacuum distillation device as described above, in which the inner diameter of the heat exchange tube increases along its length to between 2.4 and 3 times the inner diameter of the tube inlet, and in which the inner diameter of the connecting conduit gradually increases along its length to between 2.5 and 5.4 times the inner diameter of the tube outlet. During normal operation of the device of the invention, only less than 50 wt % of the feed is vaporized in the heat exchange tube in the furnace, and more feed is vaporized in the connecting conduit, so that at the outlet end of the conduit the feed comprises about 0.9 kg vapor per kg of feed. The invention provides improved heat transfer in the heat exchange tubes such that fouling is reduced, consequently more heat can be applied per unit of time in the heat exchange tube. This allows either heating of the feed to a higher temperature or increasing the throughput for the same temperature.

  4. Diffraction effects and inelastic electron transport in angle-resolved microscopic imaging applications.

    Science.gov (United States)

    Winkelmann, A; Nolze, G; Vespucci, S; Naresh-Kumar, G; Trager-Cowan, C; Vilalta-Clemente, A; Wilkinson, A J; Vos, M

    2017-09-01

    We analyse the signal formation process for scanning electron microscopic imaging applications on crystalline specimens. In accordance with previous investigations, we find nontrivial effects of incident beam diffraction on the backscattered electron distribution in energy and momentum. Specifically, incident beam diffraction causes angular changes of the backscattered electron distribution which we identify as the dominant mechanism underlying pseudocolour orientation imaging using multiple, angle-resolving detectors. Consequently, diffraction effects of the incident beam and their impact on the subsequent coherent and incoherent electron transport need to be taken into account for an in-depth theoretical modelling of the energy- and momentum distribution of electrons backscattered from crystalline sample regions. Our findings have implications for the level of theoretical detail that can be necessary for the interpretation of complex imaging modalities such as electron channelling contrast imaging (ECCI) of defects in crystals. If the solid angle of detection is limited to specific regions of the backscattered electron momentum distribution, the image contrast that is observed in ECCI and similar applications can be strongly affected by incident beam diffraction and topographic effects from the sample surface. As an application, we demonstrate characteristic changes in the resulting images if different properties of the backscattered electron distribution are used for the analysis of a GaN thin film sample containing dislocations. © 2017 The Authors. Journal of Microscopy published by JohnWiley & Sons Ltd on behalf of Royal Microscopical Society.

  5. Silicon-germanium (Sige) nanostructures production, properties and applications in electronics

    CERN Document Server

    Usami, N

    2011-01-01

    Nanostructured silicon-germanium (SiGe) provides the prospect of novel and enhanced electronic device performance. This book reviews the materials science and technology of SiGe nanostructures, including crystal growth, fabrication of nanostructures, material properties and applications in electronics.$bNanostructured silicon-germanium (SiGe) opens up the prospects of novel and enhanced electronic device performance, especially for semiconductor devices. Silicon-germanium (SiGe) nanostructures reviews the materials science of nanostructures and their properties and applications in different electronic devices. The introductory part one covers the structural properties of SiGe nanostructures, with a further chapter discussing electronic band structures of SiGe alloys. Part two concentrates on the formation of SiGe nanostructures, with chapters on different methods of crystal growth such as molecular beam epitaxy and chemical vapour deposition. This part also includes chapters covering strain engineering and mo...

  6. PARAFFIN SEPARATION VACUUM DISTILLATION

    Directory of Open Access Journals (Sweden)

    Zaid A. Abdulrahman

    2013-05-01

    Full Text Available Simulated column performance curves were constructed for existing paraffin separation vacuum distillation column in LAB plant (Arab Detergent Company/Baiji-Iraq. The variables considered in this study are the thermodynamic model option, top vacuum pressure, top and bottom temperatures, feed temperature, feed composition & reflux ratio. Also simulated columns profiles for the temperature, vapor & liquid flow rates composition were constructed. Four different thermodynamic model options (SRK, TSRK, PR, and ESSO were used, affecting the results within 1-25% variation for the most cases.The simulated results show that about 2% to 8 % of paraffin (C10, C11, C12, & C13 present at the bottom stream which may cause a problem in the LAB plant. The major variations were noticed for the top temperature & the  paraffin weight fractions at bottom section with top vacuum pressure. The bottom temperature above 240 oC is not recommended because the total bottom flow rate decreases sharply, where as  the weight fraction of paraffins decrease slightly. The study gives evidence about a successful simulation with CHEMCAD

  7. Microfabrication Techniques for Millimeter Wave Vacuum Electronics

    Science.gov (United States)

    2015-01-01

    Figure 4. (a) 220 GHz TWT circuit fabricated by UV-LIGA, (b) completed compact tube, (c) small signal gain, (d) power drive curve achieving 63 W...output. Demonstration A 220 GHz traveling wave tube ( TWT ) circuit was created using the UV-LIGA method with a photomask in two layers with the...gain TWTs . Acknowledgements This work was funded by the U.S. Office of Naval Research. The authors wish to thank R. E. Myers, B. S. Albright, and

  8. INVESTIGATION OF TITANIUM BONDED GRAPHITE FOAM COMPOSITES FOR MICRO ELECTRONIC MECHANICAL SYSTEMS (MEMS) APPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Menchhofer, Paul A [ORNL; Bozorgi, Payam [ORNL

    2016-04-01

    PiMEMS Inc. (Santa Barbara, CA) in collaboration with ORNL investigated the use of Titanium Bonded Graphite Foam Composites (TBGC) for thermal mitigation in Micro Electronic Mechanical Systems (MEMS) applications. Also considered were potentially new additive manufacturing routes to producing novel high surface area micro features and diverse shaped heat transfer components for numerous lightweight MEMs applications.

  9. Silicon material technology status. [assessment for electronic and photovoltaic applications

    Science.gov (United States)

    Lutwack, R.

    1983-01-01

    Silicon has been the basic element for the electronic and photovoltaic industries. The use of silicon as the primary element for terrestrial photovoltaic solar arrays is projected to continue. The reasons for this projection are related to the maturity of silicon technology, the ready availability of extremely pure silicon, the performance of silicon solar cells, and the considerable present investment in technology and manufacturing facilities. The technologies for producing semiconductor grade silicon and, to a lesser extent, refined metallurgical grade silicon are considered. It is pointed out that nearly all of the semiconductor grade silicon is produced by processes based on the Siemens deposition reactor, a technology developed 26 years ago. The state-of-the-art for producing silicon by this process is discussed. It is expected that efforts to reduce polysilicon process costs will continue.

  10. Applications of damage models to durability investigations for electronic connectors

    Energy Technology Data Exchange (ETDEWEB)

    Liao, K.-C. [Department of Mechanical Engineering, National Yunlin University of Science and Technology, 123 University Road, Section 3, Douliou, Yunlin 64002, Taiwan (China)], E-mail: kokki@yuntech.edu.tw; Chang, C.-C. [Department of Mechanical Engineering, National Yunlin University of Science and Technology, 123 University Road, Section 3, Douliou, Yunlin 64002, Taiwan (China)

    2009-01-15

    Contact forces between terminals of an electronic connector and the corresponding counterparts play an important role on signal transmission. The mated terminal with insufficient contact force might severely raise electrical resistance and induce intermittence or disconnection of current eventually. The contact force of the terminal could decay dramatically after several thousand mating/unmating cycles. Critical plane approaches are adopted to estimate the service life indicating the number of cycles as the contact force of the terminal degrades beneath the certain value in the present study. Damage parameters based on various criteria are evaluated for the terminal under the cyclic loading conditions. Relationships among the damage parameter, the contact force reduction ratio, and the number of cycles are then constructed by linking numerical results to experimental measurements. It is validated that the Smith-Watson-Topper criterion could be successfully applied to the service life assessment of the terminal.

  11. Application of CO2 laser for electronic components soldering

    Science.gov (United States)

    Mascorro-Pantoja, J.; Soto-Bernal, J. J.; Nieto-Pérez, M.; Gonzalez-Mota, R.; Rosales-Candelas, I.

    2011-10-01

    Laser provides a high controllable and localized spot for soldering joint formation and this is a valuable tool in Sn/Pb Soldering process on electronic industry, in recent years, laser beam welding has become an emerging welding technique, the use of laser in welding area is a high efficiency method. A 60 Watts CO2 continuous laser was used on this study, during welding experimental results indicated the laser could significantly improve speed and weld quality. In this work, the welding interactions of CO2 laser with Sn/Pb wire have been investigated in details through varying the energy ratios of laser. And at the same time, the effect of distance from laser spot to material.

  12. Synthesis and electrical properties of silver nanoplates for electronic applications

    Directory of Open Access Journals (Sweden)

    Xiong Nana

    2015-06-01

    Full Text Available In this paper, silver nanoplates of 100 to 500 nm size were synthesized by reduction of silver nitrate with N,Ndimethylformamide, using poly(vinylpyrolidone as a surfactant and ferric chloride as a controlling agent, at 120 to 160 °C for 5 to 24 hours. The influence of the concentration of ferric chloride, the reaction temperature and reaction time on the morphology of the product has been investigated by transmission electron microscopy, scanning electron microscopy and UV-Vis spectroscopy. The results indicated that the products obtained at the low reaction temperature and short reaction time in the presence of FeCl3 in the reaction solution were in the form of silver nanoplates, whose morphology was mainly triangular and hexagonal. In addition, the size and thickness of the nanoplates increased with increasing of the FeCl3 concentration. At a high reaction temperature and long reaction time, the truncated triangle and hexagonal nanoplates were mainly produced. Furthermore, the sintering behavior of nanoplates was studied and the results showed that sintering of the silver nanoplates started at 180 °C, and a typical sintering behavior was observed at higher temperatures. The incorporation of the silver nanoplates into the polymer matrix with micro-sized silver flakes led to an increase in the matrix resistivity in almost all cases, especially at high fractions and low curing temperatures. The curing temperature had an influence on the resistivity of the conductive adhesives filled with micro-sized silver flakes and silver nanoplates due to sintering of the silver nanoplates.

  13. CMOS-Technology-Enabled Flexible and Stretchable Electronics for Internet of Everything Applications

    KAUST Repository

    Hussain, Aftab M.

    2015-11-26

    Flexible and stretchable electronics can dramatically enhance the application of electronics for the emerging Internet of Everything applications where people, processes, data and devices will be integrated and connected, to augment quality of life. Using naturally flexible and stretchable polymeric substrates in combination with emerging organic and molecular materials, nanowires, nanoribbons, nanotubes, and 2D atomic crystal structured materials, significant progress has been made in the general area of such electronics. However, high volume manufacturing, reliability and performance per cost remain elusive goals for wide commercialization of these electronics. On the other hand, highly sophisticated but extremely reliable, batch-fabrication-capable and mature complementary metal oxide semiconductor (CMOS)-based technology has facilitated tremendous growth of today\\'s digital world using thin-film-based electronics; in particular, bulk monocrystalline silicon (100) which is used in most of the electronics existing today. However, one fundamental challenge is that state-of-the-art CMOS electronics are physically rigid and brittle. Therefore, in this work, how CMOS-technology-enabled flexible and stretchable electronics can be developed is discussed, with particular focus on bulk monocrystalline silicon (100). A comprehensive information base to realistically devise an integration strategy by rational design of materials, devices and processes for Internet of Everything electronics is offered. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. An Evaluation of Dynamic Partial Reconfiguration for Signal and Image Processing in Professional Electronics Applications

    Directory of Open Access Journals (Sweden)

    Philippe Manet

    2009-02-01

    Full Text Available Signal and image processing applications require a lot of computing resources. For low-volume applications like in professional electronics applications, FPGA are used in combination with DSP and GPP in order to reach the performances required by the product roadmaps. Nevertheless, FPGA designs are static, which raises a flexibility issue with new complex or software defined applications like software-defined radio (SDR. In this scope, dynamic partial reconfiguration (DPR is used to bring a virtualization layer upon the static hardware of FPGA. During the last decade, DPR has been widely studied in academia. Nevertheless, there are very few real applications using it, and therefore, there is a lack of feedback providing relevant issues to address in order to improve its applicability. This paper evaluates the interest and limitations when using DPR in professional electronics applications and provides guidelines to improve its applicability. It makes a fair evaluation based on experiments made on a set of signal and image processing applications. It identifies the missing elements of the design flow to use DPR in professional electronics applications. Finally, it introduces a fast reconfiguration manager providing an 84-time improvement compared to the vendor solution.

  15. An Evaluation of Dynamic Partial Reconfiguration for Signal and Image Processing in Professional Electronics Applications

    Directory of Open Access Journals (Sweden)

    Aulagnier Denis

    2008-01-01

    Full Text Available Abstract Signal and image processing applications require a lot of computing resources. For low-volume applications like in professional electronics applications, FPGA are used in combination with DSP and GPP in order to reach the performances required by the product roadmaps. Nevertheless, FPGA designs are static, which raises a flexibility issue with new complex or software defined applications like software-defined radio (SDR. In this scope, dynamic partial reconfiguration (DPR is used to bring a virtualization layer upon the static hardware of FPGA. During the last decade, DPR has been widely studied in academia. Nevertheless, there are very few real applications using it, and therefore, there is a lack of feedback providing relevant issues to address in order to improve its applicability. This paper evaluates the interest and limitations when using DPR in professional electronics applications and provides guidelines to improve its applicability. It makes a fair evaluation based on experiments made on a set of signal and image processing applications. It identifies the missing elements of the design flow to use DPR in professional electronics applications. Finally, it introduces a fast reconfiguration manager providing an 84-time improvement compared to the vendor solution.

  16. CMOS technology: a critical enabler for free-form electronics-based killer applications

    KAUST Repository

    Hussain, Muhammad Mustafa

    2016-05-17

    Complementary metal oxide semiconductor (CMOS) technology offers batch manufacturability by ultra-large-scaleintegration (ULSI) of high performance electronics with a performance/cost advantage and profound reliability. However, as of today their focus has been on rigid and bulky thin film based materials. Their applications have been limited to computation, communication, display and vehicular electronics. With the upcoming surge of Internet of Everything, we have critical opportunity to expand the world of electronics by bridging between CMOS technology and free form electronics which can be used as wearable, implantable and embedded form. The asymmetry of shape and softness of surface (skins) in natural living objects including human, other species, plants make them incompatible with the presently available uniformly shaped and rigidly structured today’s CMOS electronics. But if we can break this barrier then we can use the physically free form electronics for applications like plant monitoring for expansion of agricultural productivity and quality, we can find monitoring and treatment focused consumer healthcare electronics – and many more creative applications. In our view, the fundamental challenge is to engage the mass users to materialize their creative ideas. Present form of electronics are too complex to understand, to work with and to use. By deploying game changing additive manufacturing, low-cost raw materials, transfer printing along with CMOS technology, we can potentially stick high quality CMOS electronics on any existing objects and embed such electronics into any future objects that will be made. The end goal is to make them smart to augment the quality of our life. We use a particular example on implantable electronics (brain machine interface) and its integration strategy enabled by CMOS device design and technology run path. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is

  17. CMOS technology: a critical enabler for free-form electronics-based killer applications

    Science.gov (United States)

    Hussain, Muhammad M.; Hussain, Aftab M.; Hanna, Amir

    2016-05-01

    Complementary metal oxide semiconductor (CMOS) technology offers batch manufacturability by ultra-large-scaleintegration (ULSI) of high performance electronics with a performance/cost advantage and profound reliability. However, as of today their focus has been on rigid and bulky thin film based materials. Their applications have been limited to computation, communication, display and vehicular electronics. With the upcoming surge of Internet of Everything, we have critical opportunity to expand the world of electronics by bridging between CMOS technology and free form electronics which can be used as wearable, implantable and embedded form. The asymmetry of shape and softness of surface (skins) in natural living objects including human, other species, plants make them incompatible with the presently available uniformly shaped and rigidly structured today's CMOS electronics. But if we can break this barrier then we can use the physically free form electronics for applications like plant monitoring for expansion of agricultural productivity and quality, we can find monitoring and treatment focused consumer healthcare electronics - and many more creative applications. In our view, the fundamental challenge is to engage the mass users to materialize their creative ideas. Present form of electronics are too complex to understand, to work with and to use. By deploying game changing additive manufacturing, low-cost raw materials, transfer printing along with CMOS technology, we can potentially stick high quality CMOS electronics on any existing objects and embed such electronics into any future objects that will be made. The end goal is to make them smart to augment the quality of our life. We use a particular example on implantable electronics (brain machine interface) and its integration strategy enabled by CMOS device design and technology run path.

  18. Increasing the shelf- life of papaya through vacuum packing

    National Research Council Canada - National Science Library

    Padmanaban, Geetha; Singaravelu, Kanchana; Annavi, Susheela Thirumaran

    2014-01-01

    .... Papaya fruits were pretreated with waxing, oil application, purafil packets, tissue paper wrapping given along with control and were packed in 150 gauge thickness polyethylene film bags under vacuum...

  19. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    Science.gov (United States)

    Teng, Chen; Elias, Luis R.

    1995-02-01

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations.

  20. Graphene-Based Chemical Vapor Sensors for Electronic Nose Applications

    Science.gov (United States)

    Nallon, Eric C.

    An electronic nose (e-nose) is a biologically inspired device designed to mimic the operation of the olfactory system. The e-nose utilizes a chemical sensor array consisting of broadly responsive vapor sensors, whose combined response produces a unique pattern for a given compound or mixture. The sensor array is inspired by the biological function of the receptor neurons found in the human olfactory system, which are inherently cross-reactive and respond to many different compounds. The use of an e-nose is an attractive approach to predict unknown odors and is used in many fields for quantitative and qualitative analysis. If properly designed, an e-nose has the potential to adapt to new odors it was not originally designed for through laboratory training and algorithm updates. This would eliminate the lengthy and costly R&D costs associated with materiel and product development. Although e-nose technology has been around for over two decades, much research is still being undertaken in order to find new and more diverse types of sensors. Graphene is a single-layer, 2D material comprised of carbon atoms arranged in a hexagonal lattice, with extraordinary electrical, mechanical, thermal and optical properties due to its 2D, sp2-bonded structure. Graphene has much potential as a chemical sensing material due to its 2D structure, which provides a surface entirely exposed to its surrounding environment. In this configuration, every carbon atom in graphene is a surface atom, providing the greatest possible surface area per unit volume, so that electron transport is highly sensitive to adsorbed molecular species. Graphene has gained much attention since its discovery in 2004, but has not been realized in many commercial electronics. It has the potential to be a revolutionary material for use in chemical sensors due to its excellent conductivity, large surface area, low noise, and versatile surface for functionalization. In this work, graphene is incorporated into a

  1. Analytical distance distributions in systems of spherical symmetry with applications to double electron-electron resonance

    Science.gov (United States)

    Kattnig, Daniel R.; Hinderberger, Dariush

    2013-05-01

    Based on a simple geometrical approach, we derive analytical expression of the probability density functions (pdfs) of distance of probe molecules distributed homogeneously in spherical aggregates with shell structure. These distance distributions can be utilized in the investigation of double electron-electron resonance (DEER) data of disordered nanometer-sized spin clusters. Structural insights and geometrical parameters of the aggregates can be extracted by modeling the DEER time traces based on the analytical pdfs. This approach is efficient and avoids difficulties of the model-free solution of the inverse problem that are related to multi-spin effects, limited excitation bandwidth, bias introduced by the regularization scheme, or ambiguity resulting from broad distance distributions. The derived pdfs can serve as building blocks, from which the distance distributions in arbitrary spherically symmetric objects can be assembled. The scenario of the pumped species being chemically distinct from the observed species is covered as well as that of a single type of probe molecules. We demonstrate the merits of analytical distance distributions by studying the distribution of three different spin probes in SDS micelles. By simultaneously analyzing DEER data corresponding to different spin probe concentrations, the distribution of the spin probes over the micelle can be determined. Employing Bayesian inference it is found that for all probes studied, a spherical shell model is most appropriate among the studied models and by orders of magnitude more likely than a homogeneous distribution in a ball. This statement also applies to probes that are deemed nonpolar. We envisage that the spin probe distributions in disordered soft and hard matter systems can now be quantified using DEER spectroscopy with greater precision and reduced ambiguity.

  2. Vacuum radiation induced by time dependent electric field

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bo, E-mail: zhangbolfrc@caep.cn [Department of High Energy Density Physics, Research Center of Laser Fusion, 621900, Mianyang, Sichuan (China); Laboratory of Science and Technology on Plasma Physics, Research Center of Laser Fusion, 621900, Mianyang, Sichuan (China); Zhang, Zhi-meng; Hong, Wei; He, Shu-Kai; Teng, Jian [Department of High Energy Density Physics, Research Center of Laser Fusion, 621900, Mianyang, Sichuan (China); Laboratory of Science and Technology on Plasma Physics, Research Center of Laser Fusion, 621900, Mianyang, Sichuan (China); Gu, Yu-qiu, E-mail: yqgu@caep.cn [Department of High Energy Density Physics, Research Center of Laser Fusion, 621900, Mianyang, Sichuan (China); Laboratory of Science and Technology on Plasma Physics, Research Center of Laser Fusion, 621900, Mianyang, Sichuan (China)

    2017-04-10

    Many predictions of new phenomena given by strong field quantum electrodynamics (SFQED) will be tested on next generation multi-petawatt laser facilities in the near future. These new phenomena are basis to understand physics in extremely strong electromagnetic fields therefore have attracted wide research interest. Here we discuss a new SFQED phenomenon that is named as vacuum radiation. In vacuum radiation, a virtual electron loop obtain energy from time dependent external electric field and radiate an entangled photon pair. Features of vacuum radiation in a locally time dependent electric field including spectrum, characteristic temperature, production rate and power are given.

  3. Vacuum radiation induced by time dependent electric field

    Directory of Open Access Journals (Sweden)

    Bo Zhang

    2017-04-01

    Full Text Available Many predictions of new phenomena given by strong field quantum electrodynamics (SFQED will be tested on next generation multi-petawatt laser facilities in the near future. These new phenomena are basis to understand physics in extremely strong electromagnetic fields therefore have attracted wide research interest. Here we discuss a new SFQED phenomenon that is named as vacuum radiation. In vacuum radiation, a virtual electron loop obtain energy from time dependent external electric field and radiate an entangled photon pair. Features of vacuum radiation in a locally time dependent electric field including spectrum, characteristic temperature, production rate and power are given.

  4. Note: Triggering behavior of a vacuum arc plasma source.

    Science.gov (United States)

    Lan, C H; Long, J D; Zheng, L; Dong, P; Yang, Z; Li, J; Wang, T; He, J L

    2016-08-01

    Axial symmetry of discharge is very important for application of vacuum arc plasma. It is discovered that the triggering method is a significant factor that would influence the symmetry of arc discharge at the final stable stage. Using high-speed multiframe photography, the transition processes from cathode-trigger discharge to cathode-anode discharge were observed. It is shown that the performances of the two triggering methods investigated are quite different. Arc discharge triggered by independent electric source can be stabilized at the center of anode grid, but it is difficult to achieve such good symmetry through resistance triggering. It is also found that the triggering process is highly correlated to the behavior of emitted electrons.

  5. Particles and Antiparticles in the Planck Vacuum Theory

    Directory of Open Access Journals (Sweden)

    Daywitt W. C.

    2011-01-01

    Full Text Available This short note sheds some light on the negative energy vacuum state by expanding the Planck vacuum (PV model and taking a closer look at the particle-antiparticle nature of the Dirac equation. Results of the development are briefly discussed with regard to the complexity of the PV interaction with the massless free charge, the Dirac electron, and the proton; an exercise that may lead to a better proton model.

  6. Semiconductor cavity QED: Bandgap induced by vacuum fluctuations

    OpenAIRE

    Espinosa-Ortega, T.; Kyriienko, O.; Kibis, O. V.; Shelykh, I. A.

    2014-01-01

    We consider theoretically a semiconductor nanostructure embedded in one-dimensional microcavity and study the modification of its electron energy spectrum by the vacuum fluctuations of the electromagnetic field. To solve the problem, a non-perturbative diagrammatic approach based on the Green's function formalism is developed. It is shown that the interaction of the system with the vacuum fluctuations of the optical cavity opens gaps within the valence band of the semiconductor. The approach ...

  7. Optical and Electronic NOx Sensors for Applications in Mechatronics

    Science.gov (United States)

    Di Franco, Cinzia; Elia, Angela; Spagnolo, Vincenzo; Scamarcio, Gaetano; Lugarà, Pietro Mario; Ieva, Eliana; Cioffi, Nicola; Torsi, Luisa; Bruno, Giovanni; Losurdo, Maria; Garcia, Michael A.; Wolter, Scott D.; Brown, April; Ricco, Mario

    2009-01-01

    Current production and emerging NOx sensors based on optical and nanomaterials technologies are reviewed. In view of their potential applications in mechatronics, we compared the performance of: i) Quantum cascade lasers (QCL) based photoacoustic (PA) systems; ii) gold nanoparticles as catalytically active materials in field-effect transistor (FET) sensors, and iii) functionalized III-V semiconductor based devices. QCL-based PA sensors for NOx show a detection limit in the sub part-per-million range and are characterized by high selectivity and compact set-up. Electrochemically synthesized gold-nanoparticle FET sensors are able to monitor NOx in a concentration range from 50 to 200 parts per million and are suitable for miniaturization. Porphyrin-functionalized III-V semiconductor materials can be used for the fabrication of a reliable NOx sensor platform characterized by high conductivity, corrosion resistance, and strong surface state coupling. PMID:22412315

  8. Optical microresonator for application to an opto-electronic oscillator

    Science.gov (United States)

    Wu, Yu-Mei; Vivien, Laurent; Cassan, Eric; Luong, Vu Hai Nam; Nguyen, Lam Duy; Journet, Bernard

    2010-02-01

    Optoelectronic oscillators are classically based on a feedback fiber loop acting as a delay line for high spectral purity. One of the problems due to long fiber loops is the size and the requirement of temperature control. Going toward integrated solutions requires the introduction of optical resonators with a very high quality factor. A structure based on silicon on insulator material has been designed for application to an oscillator working at 8 GHz. The micro-resonator has a stadium shape with a ridge of 30 nm height, 1 μm width, a millimetric radius and a gap of some microns in agreement with the required free spectral range. A quality factor of 500000 can be achieved leading to an equivalent fiber loop of 2 km.

  9. Hexavalent Chrome Free Coatings for Electronics Applications: Joint Test Report

    Science.gov (United States)

    Kessel, Kurt

    2012-01-01

    Regardless of the corrosivity of the environment, all metals require periodic maintenance activity to guard against the insidious effects of corrosion and thus ensure that alloys meet or exceed design or performance life. The standard practice for protecting metallic substrates is the application of a coating system. Applied coating systems work via a variety of methods (barrier, galvanic, and/or inhibitor) and adhere to the substrate through a combination of chemical and physical bonds. For years hexavalent chromium has been a widely used element within applied coating systems because of its self healing and corrosion resistant properties. Occupational Safety and Health Administration (OSHA) studies have concluded that hexavalent chromium (hex chrome) is carcinogenic and poses significant risk to human health. On May 5, 2011 amendments to the Defense Federal Acquisition Regulation Supplement (DFARS) were issued in the Federal Register. Subpart 223.73 prohibits contracts from requiring hexavalent chromium in deliverables unless certain exceptions apply. These exceptions include authorization from a general or flag officer and members of the Senior Executive Service from a Program Executive Office, and unmodified legacy systems. Otherwise, Subpart 252.223-7008 provides the contract clause prohibiting contractors from using or delivering hexavalent chromium in a concentration greater than 0.1 percent by weight for all new contracts and to be included down to subcontractors for supplies, maintenance and repair services, and construction materials. National Aeronautics and Space Administration (NASA), Department of Defense (DoD), and industry stakeholders continue to search for alternatives to hex chrome in coatings applications that meet their performance requirements in corrosion protection, cost, operability, and health and safety, while typically specifying that performance must be equal to or greater than existing systems.

  10. An electronic application for rapidly calculating Charlson comorbidity score

    Directory of Open Access Journals (Sweden)

    Jani Ashesh B

    2004-12-01

    Full Text Available Abstract Background Uncertainty regarding comorbid illness, and ability to tolerate aggressive therapy has led to minimal enrollment of elderly cancer patients into clinical trials and often substandard treatment. Increasingly, comorbid illness scales have proven useful in identifying subgroups of elderly patients who are more likely to tolerate and benefit from aggressive therapy. Unfortunately, the use of such scales has yet to be widely integrated into either clinical practice or clinical trials research. Methods This article reviews evidence for the validity of the Charlson Comorbidity Index (CCI in oncology and provides a Microsoft Excel (MS Excel Macro for the rapid and accurate calculation of CCI score. The interaction of comorbidity and malignant disease and the validation of the Charlson Index in oncology are discussed. Results The CCI score is based on one year mortality data from internal medicine patients admitted to an inpatient setting and is the most widely used comorbidity index in oncology. An MS Excel Macro file was constructed for calculating the CCI score using Microsoft Visual Basic. The Macro is provided for download and dissemination. The CCI has been widely used and validated throughout the oncology literature and has demonstrated utility for most major cancers. The MS Excel CCI Macro provides a rapid method for calculating CCI score with or without age adjustments. The calculator removes difficulty in score calculation as a limitation for integration of the CCI into clinical research. The simple nature of the MS Excel CCI Macro and the CCI itself makes it ideal for integration into emerging electronic medical records systems. Conclusions The increasing elderly population and concurrent increase in oncologic disease has made understanding the interaction between age and comorbid illness on life expectancy increasingly important. The MS Excel CCI Macro provides a means of increasing the use of the CCI scale in clinical

  11. X-ray free-electron lasers principles, properties and applications f*9493

    CERN Document Server

    Stöhr, J

    2002-01-01

    Creating matter from the vacuum, taking an atomic scale motion picture of a chemical process in a time of a few femtoseconds (1 fs = 10 sup - sup 1 sup 5 sec) or unraveling the complex molecular structure of a single protein or virus. These are some of the new exciting experiments envisioned with a novel radiation source, the X-ray free-electron laser (FEL). John Madey and collaborators built the first FEL in the 1970s. It is a powerful and challenging combination of particle accelerator and laser physics and technology. Until recently FELs have been operating at infrared or near ultraviolet wavelengths. A combination of theoretical, experimental, and technological advances has made possible their extension to the X-ray region. X rays have allowed us to see the invisible for almost a century. With their help we have been making great progress in understanding the properties of materials and of living systems. Today the best sources of X rays utilize synchrotron radiation from relativistic electron beams in st...

  12. Frequency mixing in accelerator based sources and application to tunable seeded free-electron lasers

    Directory of Open Access Journals (Sweden)

    C. Evain

    2014-12-01

    Full Text Available In this article we address the problem of tunability of seeded free-electron lasers (FELs, working typically in the domain of the vacuum ultraviolet. The seeding of FELs with an external laser permits us to obtain FEL pulses with both good longitudinal coherence and good stability properties (contrary to an amplification starting from noise. However, with a fixed external laser wavelength, only amplification at harmonics of this wavelength is possible. If full tunability is wanted, it is necessary to have a tunable external source; but this type of source has much less power, hence it is much harder to reach high harmonics numbers. Here we propose the so-called frequency mixing scheme (from its analogy with the similar process in nonlinear optics, based on two laser/electron interactions. Numerical and analytic studies show that it permits to increase significantly the tunability at short wavelengths using a low-energy tunable source. Numerical simulations are made with the parameters of FERMI-FEL 1, the first seeded FEL for user operation.

  13. Vacuum Simulations in High Energy Accelerators and Distribution Properties of Continuous and Discrete Particle Motions

    CERN Document Server

    Aichinger, Ida; Kersevan, Roberto

    The underlying thesis on mathematical simulation methods in application and theory is structured into three parts. The first part sets up a mathematical model capable of predicting the performance and operation of an accelerator’s vacuum system based on analytical methods. A coupled species-balance equation system describes the distribution of the gas dynamics in an ultra-high vacuum system considering impacts of conductance limitations, beam induced effects (ion-, electron-, and photon-induced de- sorption), thermal outgassing and sticking probabilities of the chamber materials. A new solving algorithm based on sparse matrix representations, is introduced and presents a closed form solution of the equation system. The model is implemented in a Python environment, named PyVasco, and is supported by a graphical user interface to make it easy available for everyone. A sensitivity analysis, a cross-check with the Test-Particle Monte Carlo simulation program Molflow+ and a comparison of the simulation results t...

  14. Vacuum filling of complex microchannels with liquid metal.

    Science.gov (United States)

    Lin, Yiliang; Gordon, Olivia; Khan, M Rashed; Vasquez, Neyanel; Genzer, Jan; Dickey, Michael D

    2017-09-12

    This paper describes the utilization of vacuum to fill complex microchannels with liquid metal. Microchannels filled with liquid metal are useful as conductors for soft and stretchable electronics, as well as for microfluidic components such as electrodes, antennas, pumps, or heaters. Liquid metals are often injected manually into the inlet of a microchannel using a syringe. Injection can only occur if displaced air in the channels has a pathway to escape, which is usually accomplished using outlets. The positive pressure (relative to atmosphere) needed to inject fluids can also cause leaks or delamination of the channels during injection. Here we show a simple and hands-free method to fill microchannels with liquid metal that addresses these issues. The process begins by covering a single inlet with liquid metal. Placing the entire structure in a vacuum chamber removes the air from the channels and the surrounding elastomer. Restoring atmospheric pressure in the chamber creates a positive pressure differential that pushes the metal into the channels. Experiments and a simple model of the filling process both suggest that the elastomeric channel walls absorb residual air displaced by the metal as it fills the channels. Thus, the metal can fill dead-ends with features as small as several microns and branched structures within seconds without the need for any outlets. The method can also fill completely serpentine microchannels up to a few meters in length. The ability to fill dense and complex geometries with liquid metal in this manner may enable broader application of liquid metals in electronic and microfluidic applications.

  15. The vacuum platform

    Science.gov (United States)

    McNab, A.

    2017-10-01

    This paper describes GridPP’s Vacuum Platform for managing virtual machines (VMs), which has been used to run production workloads for WLCG and other HEP experiments. The platform provides a uniform interface between VMs and the sites they run at, whether the site is organised as an Infrastructure-as-a-Service cloud system such as OpenStack, or an Infrastructure-as-a-Client system such as Vac. The paper describes our experience in using this platform, in developing and operating VM lifecycle managers Vac and Vcycle, and in interacting with VMs provided by LHCb, ATLAS, ALICE, CMS, and the GridPP DIRAC service to run production workloads.

  16. Ruthenium(II) Complex Based Photodiode for Organic Electronic Applications

    Science.gov (United States)

    Tataroglu, A.; Ocaya, R.; Dere, A.; Dayan, O.; Serbetci, Z.; Al-Sehemi, Abdullah G.; Soylu, M.; Al-Ghamdi, Ahmed A.; Yakuphanoglu, F.

    2018-01-01

    In this study, the electrical and photoresponse properties of a photovoltaic device with Ruthenium(II) complex interfacial thin film were investigated. Heteroleptic Ru(II) complex including bidentate and tridentate ligands thin film was coated on n-Si substrate by the spin coating technique. From current-voltage ( I- V) measurements of an Au/Ru(II)/n-Si photodiode, it is observed that the reverse bias current under light is higher than that of the current in the dark. This indicates that the photodiode exhibits a photoconducting characteristic. The transient measurements such as photocurrent, photocapacitance and photoconductance were performed under various illumination conditions. These measurements indicate that the photodiode has a high photoresponsivity. The electrical parameters such as barrier height (Φb), ideality factor ( n) and series resistance ( R s) of the photodiode were determined from the analysis of I- V characteristics. Moreover, the capacitance/conductance-voltage characteristics of the photodiode highly depend on both voltage and frequency. Results show that the heterojunction can be used for various optoelectronic applications.

  17. Ruthenium(II) Complex Based Photodiode for Organic Electronic Applications

    Science.gov (United States)

    Tataroglu, A.; Ocaya, R.; Dere, A.; Dayan, O.; Serbetci, Z.; Al-Sehemi, Abdullah G.; Soylu, M.; Al-Ghamdi, Ahmed A.; Yakuphanoglu, F.

    2017-10-01

    In this study, the electrical and photoresponse properties of a photovoltaic device with Ruthenium(II) complex interfacial thin film were investigated. Heteroleptic Ru(II) complex including bidentate and tridentate ligands thin film was coated on n-Si substrate by the spin coating technique. From current-voltage (I-V) measurements of an Au/Ru(II)/n-Si photodiode, it is observed that the reverse bias current under light is higher than that of the current in the dark. This indicates that the photodiode exhibits a photoconducting characteristic. The transient measurements such as photocurrent, photocapacitance and photoconductance were performed under various illumination conditions. These measurements indicate that the photodiode has a high photoresponsivity. The electrical parameters such as barrier height (Φb), ideality factor (n) and series resistance (R s) of the photodiode were determined from the analysis of I-V characteristics. Moreover, the capacitance/conductance-voltage characteristics of the photodiode highly depend on both voltage and frequency. Results show that the heterojunction can be used for various optoelectronic applications.

  18. Graphene Inks with Cellulosic Dispersants: Development and Applications for Printed Electronics

    Science.gov (United States)

    Secor, Ethan Benjamin

    Graphene offers promising opportunities for applications in printed and flexible electronic devices due to its high electrical and thermal conductivity, mechanical flexibility and strength, and chemical and environmental stability. However, scalable production and processing of graphene presents a critical technological challenge preventing the application of graphene for flexible electronic interconnects, electrochemical energy storage, and chemically robust electrical contacts. In this thesis, a promising and versatile platform for the production, patterning, and application of graphene inks is presented based on cellulosic dispersants. Graphene is produced from flake graphite using scalable liquid-phase exfoliation methods, using the polymers ethyl cellulose and nitrocellulose as multifunctional dispersing agents. These cellulose derivatives offer high colloidal stability and broadly tunable rheology for graphene dispersions, providing an effective and tunable platform for graphene ink development. Thermal or photonic annealing decomposes the polymer dispersant to yield high conductivity, flexible graphene patterns for various electronics applications. In particular, the chemical stability of graphene enables robust electrical contacts for ceramic, metallic, organic and electrolytic materials, validating the diverse applicability of graphene in printed electronics. Overall, the strategy for graphene ink design presented here offers a simple, efficient, and versatile method for integrating graphene in a wide range of printed devices and systems, providing both fundamental insight for nanomaterial ink development and realistic opportunities for practical applications.

  19. Power Electronics for Distributed Energy Systems and Transmission and Distribution Applications: Assessing the Technical Needs for Utility Applications

    Energy Technology Data Exchange (ETDEWEB)

    Tolbert, L.M.

    2005-12-21

    Power electronics can provide utilities the ability to more effectively deliver power to their customers while providing increased reliability to the bulk power system. In general, power electronics is the process of using semiconductor switching devices to control and convert electrical power flow from one form to another to meet a specific need. These conversion techniques have revolutionized modern life by streamlining manufacturing processes, increasing product efficiencies, and increasing the quality of life by enhancing many modern conveniences such as computers, and they can help to improve the delivery of reliable power from utilities. This report summarizes the technical challenges associated with utilizing power electronics devices across the entire spectrum from applications to manufacturing and materials development, and it provides recommendations for research and development (R&D) needs for power electronics systems in which the U.S. Department of Energy (DOE) could make a substantial impact toward improving the reliability of the bulk power system.

  20. Diffraction effects and inelastic electron transport in angle-resolved microscopic imaging applications

    OpenAIRE

    Winkelmann, A.; Nolze, G.; Vespucci, S.; Naresh-Kumar, G; Trager-Cowan, C.; Vilalta-Clementes, A; Wilkinson, A; De Vos, M.

    2017-01-01

    We analyse the signal formation process for scanning electronmicroscopic imaging applications on crystalline specimens. Inaccordance with previous investigations, we find nontrivialeffects of incident beam diffraction on the backscattered elec-tron distribution in energy and momentum. Specifically, inci-dent beam diffraction causes angular changes of the backscat-tered electron distribution which we identify as the dominantmechanism underlying pseudocolour orientation imaging us-ing multiple,...