WorldWideScience

Sample records for urban sewage loadings

  1. Urban Sewage Sludge, Sustainability, and Transition for Eco-City

    DEFF Research Database (Denmark)

    Ren, Jingzheng; Liang, Hanwei; Chan, Felix T. S.

    2017-01-01

    The treatment of urban sewage sludge is of vital importance for mitigating the risks of environmental contaminations, and the negative effects on human health. However, there are usually various different technologies for the treatment of urban sewage sludge; thus, it is difficult for decision......-makers/stakeholders to select the most sustainable technology among multiple alternatives. This study aims at developing a generic multi-criteria decision support framework for sustainability assessment of the technologies for the treatment of urban sewage sludge. A generic criteria system including both hard and soft criteria...... in economic, environmental, social and technological aspects was developed for sustainability assessment. The improved analytic hierarchy process method, namely Best-Worst method, was employed to determine the weights of the criteria and the relative priorities of the technologies with respect to the soft...

  2. Quantification of human-associated fecal indicators reveal sewage from urban watersheds as a source of pollution to Lake Michigan

    Science.gov (United States)

    Olds, Hayley T.; Dila, Deborah K.; Bootsma, Melinda J.; Corsi, Steven; McLellan, Sandra L.

    2016-01-01

    Sewage contamination of urban waterways from sewer overflows and failing infrastructure is a major environmental and public health concern. Fecal coliforms (FC) are commonly employed as fecal indicator bacteria, but do not distinguish between human and non-human sources of fecal contamination. Human Bacteroides and humanLachnospiraceae, two genetic markers for human-associated indicator bacteria, were used to identify sewage signals in two urban rivers and the estuary that drains to Lake Michigan. Grab samples were collected from the rivers throughout 2012 and 2013 and hourly samples were collected in the estuary across the hydrograph during summer 2013. Human Bacteroides and human Lachnospiraceae were highly correlated with each other in river samples (Pearson’s r = 0.86), with average concentrations at most sites elevated during wet weather. These human indicators were found during baseflow, indicating that sewage contamination is chronic in these waterways. FC are used for determining total maximum daily loads (TMDLs) in management plans; however, FC concentrations alone failed to prioritize river reaches with potential health risks. While 84% of samples with >1000 CFU/100 ml FC had sewage contamination, 52% of samples with moderate (200–1000 CFU/100 ml) and 46% of samples with low (events and was highest during an event with a short duration of intense rain. This work demonstrates urban areas have unrecognized sewage inputs that may not be adequately prioritized for remediation by the TMDL process. Further analysis using these approaches could determine relationships between land use, storm characteristics, and other factors that drive sewage contamination in urban waterways.

  3. Estrogenic compounds in Tunisian urban sewage treatment plant: occurrence, removal and ecotoxicological impact of sewage discharge and sludge disposal.

    Science.gov (United States)

    Belhaj, Dalel; Athmouni, Khaled; Jerbi, Bouthaina; Kallel, Monem; Ayadi, Habib; Zhou, John L

    2016-12-01

    The occurrence, fate and ecotoxicological assessment of selected estrogenic compounds were investigated at Tunisian urban sewage treatment plant. The influents, effluents, as well as primary, secondary and dehydrated sludge, were sampled and analyzed for the target estrogens to evaluate their fate. All target compounds were detected in both sewage and sludge with mean concentrations from 0.062 to 0.993 μg L -1 and from 11.8 to 792.9 μg kg -1 dry weight, respectively. A wide range of removal efficiencies during the treatment processes were observed, from 6.3 % for estrone to 76.8 % for estriol. Ecotoxicological risk assessment revealed that the highest ecotoxicological risk in sewage effluent and dehydrated sludge was due to 17β-estradiol with a risk quotient (RQ) of 4.6 and 181.9, respectively, and 17α-ethinylestradiol with RQ of 9.8 and 14.85, respectively. Ecotoxicological risk after sewage discharge and sludge disposal was limited to the presence of 17β-estradiol in dehydrated-sludge amended soil with RQ of 1.38. Further control of estrogenic hormones in sewage effluent and sludge is essential before their discharge and application in order to prevent their introduction into the natural environment.

  4. Detection of enteroviruses from urban sewage in Parma.

    Science.gov (United States)

    Cesari, C; Colucci, M E; Veronesi, L; Giordano, R; Paganuzzi, F; Affanni, P; Bracchi, M T; Capobianco, E; Ferrari, G; Tanzi, Maria Luisa

    2010-12-01

    The human enteroviruses (EV) are the most common and widespread human viruses in the world. They have bowel as their natural habitat and they can spread in the environment through the faecal excretion. In the continental climate Regions these viruses may cause epidemic outbreaks in summer and fall, while in the tropical Regions the EV infections present a high incidence during all year. The symptoms can be minor or subclinic, but they can be also associated to rare and serious diseases. The aim of this study was to evaluate the environmental circulation of polioviruses and non-polio enteroviruses (NPEV) using standard methods of urban wastewater surveillance recommended by the WHO. A total of 188 wastewater samples were collected between February 2005 and December 2008 from two sewage treatment plants in Parma. The sampling was carried out twice a month. Environmental variables were collected for each day of sampling. Out of the 188 examined wastewater samples, 78.7% were positive to the enterovirus research. One out of the 148 positive samples was identified as poliovirus Sabin-like type 3. The remaining 147 positive samples were enteroviruses non polio: Coxsakieviruses and Echoviruses. All Coxsakieviruses isolated were of type B. The proposed method has shown high sensibility, also in presence of very low expected prevalence of vaccine poliovirus. It allows to verify the kind and relative frequency of enteric viruses circulating in the country, whose characteristics (virulence and pathogenicity) may vary with reference to a different epidemiologic and demographic structure of the resident population.

  5. Fast increases in urban sewage inputs to rivers of Indonesia

    NARCIS (Netherlands)

    Suwarno, D.; Löhr, A.; Kroeze, C.; Widianarko, B.

    2014-01-01

    We present estimates for nitrogen (N) and phosphorus (P) sewage inputs to 19 Indonesian rivers for 1970–2050. Future trends are based on the four scenarios of the Millennium Ecosystem Assessment. Our results indicate a rapid increase in N and P pollution from sewage over time. In 1970, N and P

  6. Treating urban sewage using constructed wetlands; Depuracion de aguas residuales urbanas mediante humedales contruidos

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, J. [ETS Camins, Canals i Ports. UPC. Barcelona (Spain); Ruiz, A. [Biologa. Barcelona. (Spain); Junqueras, X. [Biologo. Barcelona (Spain)

    1997-09-01

    Constructed wetlands are a low-cost alternative for treating sewage from small urbanized areas. The ``Can Massaguer`` children`s holiday home has a 230 m``2 subsurface flow wetland for secondary treatment of the sewage generated by 130 people. The system comprises two porous substrate beds with macrophytes (ditch reed, Phragmites australis) and entry and exit units. Its high purification performance and nil running costs make it ideal for treating wastewaters from small built-up areas. (Author)

  7. Pharmaceutical load in sewage sludge and biochar produced by hydrothermal carbonization.

    Science.gov (United States)

    vom Eyser, C; Palmu, K; Schmidt, T C; Tuerk, J

    2015-12-15

    We investigated the removal of twelve pharmaceuticals in sewage sludge by hydrothermal carbonization (HTC), which has emerged as a technology for improving the quality of organic waste materials producing a valuable biochar material. In this study, the HTC converted sewage sludge samples to a biochar product within 4h at a temperature of 210 °C and a resulting pressure of about 15 bar. Initial pharmaceutical load of the sewage sludge was investigated as well as the residual concentrations in biochar produced from spiked and eight native sewage sludge samples from three waste water treatment plants. Additionally, the solid contents of source material and product were compared, which showed a considerable increase of the solid content after filtration by HTC. All pharmaceuticals except sulfamethoxazole, which remained below the limit of quantification, frequently occurred in the investigated sewage sludges in the μg/kg dry matter (DM) range. Diclofenac, carbamazepine, metoprolol and propranolol were detected in all sludge samples with a maximum concentration of 800 μg/kgDM for metoprolol. HTC was investigated regarding its contaminant removal efficiency using spiked sewage sludge. Pharmaceutical concentrations were reduced for seven compounds by 39% (metoprolol) to≥97% (carbamazepine). In native biochar samples the four compounds phenazone, carbamazepine, metoprolol and propranolol were detected, which confirmed that the HTC process can reduce the load of micropollutants. In contrast to the other investigated compounds phenazone concentration increased, which was further addressed in thermal behaviour studies including three structurally similar potential precursors. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Nitrous oxide emissions in the Shanghai river network: implications for the effects of urban sewage and IPCC methodology.

    Science.gov (United States)

    Yu, Zhongjie; Deng, Huanguang; Wang, Dongqi; Ye, Mingwu; Tan, Yongjie; Li, Yangjie; Chen, Zhenlou; Xu, Shiyuan

    2013-10-01

    Global nitrogen (N) enrichment has resulted in increased nitrous oxide (N(2)O) emission that greatly contributes to climate change and stratospheric ozone destruction, but little is known about the N(2)O emissions from urban river networks receiving anthropogenic N inputs. We examined N(2)O saturation and emission in the Shanghai city river network, covering 6300 km(2), over 27 months. The overall mean saturation and emission from 87 locations was 770% and 1.91 mg N(2)O-N m(-2) d(-1), respectively. Nitrous oxide (N(2)O) saturation did not exhibit a clear seasonality, but the temporal pattern was co-regulated by both water temperature and N loadings. Rivers draining through urban and suburban areas receiving more sewage N inputs had higher N(2)O saturation and emission than those in rural areas. Regression analysis indicated that water ammonium (NH(4)(+)) and dissolved oxygen (DO) level had great control on N(2)O production and were better predictors of N(2)O emission in urban watershed. About 0.29 Gg N(2)O-N yr(-1) N(2)O was emitted from the Shanghai river network annually, which was about 131% of IPCC's prediction using default emission values. Given the rapid progress of global urbanization, more study efforts, particularly on nitrification and its N(2)O yielding, are needed to better quantify the role of urban rivers in global riverine N(2)O emission. © 2013 John Wiley & Sons Ltd.

  9. Metagenomics of urban sewage identifies an extensively shared antibiotic resistome in China.

    Science.gov (United States)

    Su, Jian-Qiang; An, Xin-Li; Li, Bing; Chen, Qing-Lin; Gillings, Michael R; Chen, Hong; Zhang, Tong; Zhu, Yong-Guan

    2017-07-19

    Antibiotic-resistant pathogens are challenging treatment of infections worldwide. Urban sewage is potentially a major conduit for dissemination of antibiotic resistance genes into various environmental compartments. However, the diversity and abundance of such genes in wastewater are not well known. Here, seasonal and geographical distributions of antibiotic resistance genes and their host bacterial communities from Chinese urban sewage were characterized, using metagenomic analyses and 16S rRNA gene-based Illumina sequencing, respectively. In total, 381 different resistance genes were detected, and these genes were extensively shared across China, with no geographical clustering. Seasonal variation in abundance of resistance genes was observed, with average concentrations of 3.27 × 10 11 and 1.79 × 10 12 copies/L in summer and winter, respectively. Bacterial communities did not exhibit geographical clusters, but did show a significant distance-decay relationship (P resistome accounted for 57.7% of the total resistance genes, and was significantly associated with the core microbial community (P resistome, demonstrating the potential contribution of human gut microbiota to the dissemination of resistance elements via sewage disposal. This study provides a baseline for investigating environmental dissemination of resistance elements and raises the possibility of using the abundance of resistance genes in sewage as a tool for antibiotic stewardship.

  10. Microbial activities in a vertical-flow wetland system treating sewage sludge with high organic loads

    Energy Technology Data Exchange (ETDEWEB)

    Wang, R. Y.; Perissol, C.; Baldy, V.; Bonin, G.; Korboulewsky, N.

    2009-07-01

    The rhizosphere is the most active zone in treatment wetlands where take place physicochemical and biological processes between the substrate, plants, microorganisms, and contaminants. Microorganisms play the key role in the mineralisation of organic matter. substrate respiration and phosphatase activities (acid and alkaline) were chosen as indicators of microbial activities, and studied in a vertical-flow wetland system receiving sewage sludge with high organic loads under the Mediterranean climate. (Author)

  11. Evaluation of biochemical and redox parameters in rats fed with corn grown in soil amended with urban sewage sludge.

    Science.gov (United States)

    Grotto, Denise; Carneiro, Maria Fernanda Hornos; Sauer, Elisa; Garcia, Solange Cristina; de Melo, Wanderley José; Barbosa, Fernando

    2013-09-01

    The increased production of urban sewage sludge requires alternative methods for final disposal. A very promising choice is the use of sewage sludge as a fertilizer in agriculture, since it is rich in organic matter, macro and micronutrients. However, urban sewage sludge may contain toxic substances that may cause deleterious effects on the biota, water and soil, and consequently on humans. There is a lack of studies evaluating how safe the consumption of food cultivated in soils containing urban sewage sludge is. Thus, the aim of this paper was to evaluate biochemical and redox parameters in rats fed with corn produced in a soil treated with urban sewage sludge for a long term. For these experiments, maize plants were grown in soil amended with sewage sludge (rates of 5, 10 and 20 t/ha) or not (control). Four different diets were prepared with the corn grains produced in the field experiment, and rats were fed with these diets for 1, 2, 4, 8 and 12 weeks. Biochemical parameters (glucose, total cholesterol and fractions, triglycerides, aspartate aminotransferase and alanine aminotransferase) as well the redox state biomarkers such as reduced glutathione (GSH), malondialdehyde (MDA), catalase, glutathione peroxidase and butyrylcholinesterase (BuChE) were assessed. Our results show no differences in the biomarkers over 1 or 2 weeks. However, at 4 weeks BuChE activity was inhibited in rats fed with corn grown in soil amended with sewage sludge (5, 10 and 20 t/ha), while MDA levels increased. Furthermore, prolonged exposure to corn cultivated in the highest amount per hectare of sewage sludge (8 and 12 weeks) was associated with an increase in MDA levels and a decrease in GSH levels, respectively. Our findings add new evidence of the risks of consuming food grown with urban sewage sludge. However, considering that the amount and type of toxic substances present in urban sewage sludge varies considerably among different sampling areas, further studies are needed to

  12. Sewage-treatment under substantial load variations in winter tourism areas--a full case study.

    Science.gov (United States)

    Winkler, S; Matsché, N; Gamperer, T; Dum, M

    2004-01-01

    The sewage-load variations in winter tourism areas are characterized by sudden increases--in the range of a factor two to three--within only a few days at the start and the end of the tourist season, especially at Christmas. The sudden load increases occur during periods of low wastewater temperatures, which is an additional demanding factor with respect to nitrogen removal. A full case study was carried out at WWTP Saalfelden, which is located near one of Austria's largest skiing resorts. The plant is designed for 80,000 PE and built according to the HYBRID-concept, which is a special two stage activated sludge process for extensive nutrient removal.

  13. Distribution of human fecal marker GB-124 bacteriophages in urban sewage and reclaimed water of São Paulo city, Brazil.

    Science.gov (United States)

    Prado, Tatiana; Bruni, Antônio de Castro; Barbosa, Mikaela Renata Funada; Bonanno, Vilma Marques Santos; Garcia, Suzi Cristina; Sato, Maria Inês Zanoli

    2018-04-01

    Bacteriophages infecting Bacteroides fragilis GB-124 have been described as potential markers of human fecal contamination in water sources. The aim of this study was to evaluate the occurrence of GB-124 phages in raw sewage, secondary effluents and reclaimed water of the São Paulo city using a low-cost microbial source tracking method. Samples were collected monthly from April 2015 to March 2016 in four municipal wastewater treatment plants that operate with activated sludge processes followed by different tertiary treatments (sand-anthracite filtration, membrane bioreactor/reverse osmosis) and final chlorination. GB-124 phages were detected in 100% of the raw sewage samples, with viral loads varying from 7.5 × 10 3 to 1.32 × 10 6 PFU/L. Virus removal efficiency in activated sludge processes ranged from 1.89 to 2.31 log 10 . Frequencies of phage detection were lower in reclaimed water samples (0-22.2%). The results indicated that GB-124 phage could be a complementary low-cost viral marker for the detection of human fecal pollution in waters impacted with urban sewage in this region. However, the datasets of tertiary effluents resulted in several samples with concentrations below the detection limit (DL ≤1 PFU/mL) suggesting the need to obtain analytical methods with lower DL for greater accuracy of negative results.

  14. Pollution loads in urban runoff and sanitary wastewater.

    Science.gov (United States)

    Taebi, Amir; Droste, Ronald L

    2004-07-05

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha.year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control.

  15. Pollution loads in urban runoff and sanitary wastewater

    International Nuclear Information System (INIS)

    Taebi, Amir; Droste, Ronald L.

    2004-01-01

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha·year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control

  16. An environmental LCA of alternative scenarios of urban sewage sludge treatment and disposal

    Directory of Open Access Journals (Sweden)

    Tarantini Mario

    2007-01-01

    Full Text Available The majority of pollutants that affect wastewater are concentrated by treatment processes in sludge; it is therefore critical to have a suitable evaluation methodology of sludge management options to analyze if pollution is redirected from water to other media, such as air and soil. Life cycle assessment is one of the most widely known and internationally accepted methodologies to compare environmental impacts of processes and systems and to evaluate their sustainability in the entire life cycle. In this study the methodology was applied to assess and compare three scenarios of urban sewage sludge treatment and disposal: sludge anaerobic digestion followed by dedicated incineration, sludge incineration without previous digestion, and sludge anaerobic digestion followed by composting. The potential benefits of spreading the compost to soil were not included in the system boundaries even if, due to its nutrients contents and soil improving features, compost could partially replace the use of commercial products. The study was aimed at finding out the environmental critical points of the treatment alternatives selected and at providing a technical and scientific contribution for further debates with national and local authorities on the environmental optimization of sewage sludge management. Life cycle assessment results confirmed the major contribution of electricity and methane consumption on several environmental impact categories. Incineration contributes more than sludge composting to almost all categories, although the heavy metals content of urban wastewater sludge raises substantial concerns when composted sludge is spread to soil. In this paper the models adopted, the hypotheses assumed and the main findings of the study are presented and discussed. .

  17. Rare earth and precious elements in the urban sewage sludge and lake surface sediments under anthropogenic influence in the Republic of Benin.

    Science.gov (United States)

    Yessoufou, Arouna; Ifon, Binessi Edouard; Suanon, Fidèle; Dimon, Biaou; Sun, Qian; Dedjiho, Comlan Achille; Mama, Daouda; Yu, Chang-Ping

    2017-11-09

    Nowadays, sewage sludge and water bodies are subjected to heavy pollution due to rapid population growth and urbanization. Heavy metal pollution represents one of the main challenges threatening our environment and the ecosystem. The present work aims to evaluate the contamination state of the sewage sludge and lake sediments in the Republic of Benin. Twenty metallic elements including 15 rare earth elements (Eu, Sb, Cs, Nd, Pr, Gd, La, Ce, Tb, Sm, Dy, Ho, Eu, Yb, and Lu) and five precious elements (Ag, Au, Pd, Pt, and Ru) were investigated using inductive plasma-mass spectrometry. Results showed broad range concentrations of the elements. Ce, La, and Nd were present in both sediments and sewage sludge at concentrations ranging 5.80-41.30 mg/kg dry matter (DM), 3.23-15.60 mg/kg DM, and 2.74-19.26 mg/kg DM, respectively. Pr, Sm, Gd, Tb, Dy, Eu, Er, Yb, Cs, Ho, and Tm concentrations were lower (0.02-5.94 mg/kg DM). Among precious elements, Ag was detected at the highest concentration in all sites (0.43-4.72 mg/kg DM), followed by Pd (0.20-0.57 mg/kg DM) and Au (0.01-0.57 mg/kg DM). Ru and Pt concentrations were sewage sludge. This revealed a growing anthropogenic input which was also implied by principal component analysis. The evaluation of pollution loading index (PLI) indicated a moderate to strong contamination (0.12 ≤ PLI ≤ 0.58; 37 ≤ PLI ≤ 114, respectively, for rare earth elements and precious elements), while the degree of contamination indicated a moderate polymetallic contamination for rare earth elements and significant contamination for precious elements.

  18. Trace metal uptake by tropical vegetables grown on soil amended with urban sewage sludge

    International Nuclear Information System (INIS)

    Nabulo, G.; Black, C.R.; Young, S.D.

    2011-01-01

    Trace metal uptake was measured for tropical and temperate leafy vegetables grown on soil from an urban sewage disposal farm in the UK. Twenty-four leafy vegetables from East Africa and the UK were assessed and the five vegetable types that showed the greatest Cd concentrations were grown on eight soils differing in the severity of contamination, pH and other physico-chemical properties. The range of Cd concentrations in the edible shoots was greater for tropical vegetables than for temperate types. Metal uptake was modelled as a function of (i) total soil metal concentration, (ii) CaCl 2 -soluble metal, (iii) soil solution concentration and (iv) the activity of metal ions in soil pore water. Tropical vegetables were not satisfactorily modelled as a single generic 'green vegetable', suggesting that more sophisticated approaches to risk assessment may be required to assess hazard from peri-urban agriculture in developing countries. - Research highlights: → Cadmium uptake by tropical green vegetables varies greatly between types. → Modelling metal uptake works best for Ni, Cd and Zn but is poor for Cu, Ba and Pb. → Modelling with dilute CaCl 2 extraction is as good as metal ion activity in pore water. - Trace metal uptake by tropical leaf vegetables can be predicted from dilute CaCl 2 extraction of soil but model parameters are genotype-specific.

  19. Trace metal uptake by tropical vegetables grown on soil amended with urban sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    Nabulo, G.; Black, C.R. [School of Biosciences, University of Nottingham, University Park, Nottingham, NG7 2RD (United Kingdom); Young, S.D., E-mail: scott.young@nottingham.ac.u [School of Biosciences, University of Nottingham, University Park, Nottingham, NG7 2RD (United Kingdom)

    2011-02-15

    Trace metal uptake was measured for tropical and temperate leafy vegetables grown on soil from an urban sewage disposal farm in the UK. Twenty-four leafy vegetables from East Africa and the UK were assessed and the five vegetable types that showed the greatest Cd concentrations were grown on eight soils differing in the severity of contamination, pH and other physico-chemical properties. The range of Cd concentrations in the edible shoots was greater for tropical vegetables than for temperate types. Metal uptake was modelled as a function of (i) total soil metal concentration, (ii) CaCl{sub 2}-soluble metal, (iii) soil solution concentration and (iv) the activity of metal ions in soil pore water. Tropical vegetables were not satisfactorily modelled as a single generic 'green vegetable', suggesting that more sophisticated approaches to risk assessment may be required to assess hazard from peri-urban agriculture in developing countries. - Research highlights: Cadmium uptake by tropical green vegetables varies greatly between types. Modelling metal uptake works best for Ni, Cd and Zn but is poor for Cu, Ba and Pb. Modelling with dilute CaCl{sub 2} extraction is as good as metal ion activity in pore water. - Trace metal uptake by tropical leaf vegetables can be predicted from dilute CaCl{sub 2} extraction of soil but model parameters are genotype-specific.

  20. Application of subsurface wastewater infiltration system to on-site treatment of domestic sewage under high hydraulic loading rate

    Directory of Open Access Journals (Sweden)

    Ying-hua Li

    2015-01-01

    Full Text Available In order to enhance the hydraulic loading rate (HLR of a subsurface wastewater infiltration system (SWIS used in treating domestic sewage, the intermittent operation mode was employed in the SWIS. The results show that the intermittent operation mode contributes to the improvement of the HLR and the pollutant removal rate. When the wetting-drying ratio (RWD was 1.0, the pollutant removal rate increased by (13.6 ± 0.3% for NH3-N, (20.7 ± 1.1% for TN, (18.6 ± 0.4% for TP, (12.2 ± 0.5% for BOD, (10.1 ± 0.3% for COD, and (36.2 ± 1.2% for SS, compared with pollutant removal rates under the continuous operation mode. The pollutant removal rate declined with the increase of the HLR. The effluent quality met The Reuse of Urban Recycling Water – Water Quality Standard for Scenic Environment Use (GB/T 18921-2002 even when the HLR was as high as 10 cm/d. Hydraulic conductivity, oxidation reduction potential (ORP, the quantity of nitrifying bacteria, and the pollutant removal rate of NH3-N increased with the decrease of the RWD. For the pollutant removal rates of TP, BOD, and COD, there were no significant difference (p < 0.05 under different RWDs. The suggested RWD was 1.0. Relative contribution of the pretreatment and SWIS to the pollutant removal was examined, and more than 80% removal of NH3-N, TN, TP, COD, and BOD occurred in the SWIS.

  1. Biogas Production Experimental Research by Using Sewage Sludge Loading with Biochar Additive

    Directory of Open Access Journals (Sweden)

    Vitalij Kolodynskij

    2017-09-01

    Full Text Available Biogas – ecological fuel, which is assigned to alternative energy sources. It should be noted, that biogas – renewable energy source, which does not require any specific climatic conditions or geographical position of a country. This power source is available and can be successfully produced and used in all countries of the world. The main components of biogas – methane CH4 and carbon monoxide CO2. This gas is formed under anaerobic conditions, when microorganisms decompose biodegradable biomass. In biological sciences biomass means a living matter content, expressed in grams per unit area. Meanwhile, in the energy sector, the definition of biomass is limited and biomass is characterized as fuel source, produced from plant materials and organic waste (food waste, wood, sludge, manure, vegetables, etc.. Currently, to produce biogas from biomass, bioreactors are used worldwide. However, in order to increase the quality and yield of biogas, in the world practice various bioload additives are used: vegetable waste, clay minerals, and a large amount of the protein-containing waste. The goal – to evaluate the impact of biochar on biogas quality and yield using sewage sludge load. It was found, that 10% biochar additive increased average CH4 concentration of 7.9%, reduced the CO2 concentration of 3–4% and totally removed H2S from biogas.

  2. Heavy metal and microbial loads in sewage irrigated vegetables of Kabul, Afghanistan

    Directory of Open Access Journals (Sweden)

    Andreas Buerkert

    2011-06-01

    Full Text Available Little is known about the heavy metal and microbial contamination of vegetables produced in Central Asian cities. We therefore measured the concentration of cadmium (Cd, copper (Cu, lead (Pb, and zinc (Zn and of faecal pathogens (Coliform bacteria, Salmonella sp., Shigella sp., Ascaris lubricoides, Entamoeba sp. and pinworms [Oxyuris vermicularis syn. Enterobius vermicularis] in soil, irrigation water, and marketed vegetables of Kabul City, Afghanistan. Leaf Pb and Zn concentrations of leafy vegetables were with 1–5 and 33–160 mg kg^{-1} dry weight (DW several-fold above respective international thresholds of 0.3 mg Pb kg^{-1} and 50 mg Zn kg^{-1}. The tissue concentration of Cu was below threshold limits in all samples except for spinach in one farm. Above-threshold loads of microbes and parasites on vegetables were found in five out of six gardens with coliforms ranging from 0.5–2 × 10^7 cells 100g^{-1} fresh weight (FW, but no Salmonella and Shigella were found. Contamination with 0.2 × 10^7 eggs 100g^{-1} FW of Ascaris was detected on produce of three farms and critical concentrations of Entamoeba in a single case, while Oxyuris vermicularis, and Enterobius vermicularis were found on produce of three and four farms, respectively. Irrigation water had Ascaris, Coliforms, Salmonella, Shigella, Entamoeba, and Oxyuris vermicularis syn. Enterobius vermicularis ranging from 0.35 × 10^7 to 2 × 10^7 cells l^{-1}. The heavy metal and microbial loads on fresh UPA vegetables are likely the result of contamination from rising traffic, residues of the past decades of war and lacking treatment of sewage which needs urgent attention.

  3. Biodiversity of bacteriophages: morphological and biological properties of a large group of phages isolated from urban sewage

    OpenAIRE

    Agata Jurczak-Kurek; Tomasz Gąsior; Bożena Nejman-Faleńczyk; Sylwia Bloch; Aleksandra Dydecka; Gracja Topka; Agnieszka Necel; Magdalena Jakubowska-Deredas; Magdalena Narajczyk; Malwina Richert; Agata Mieszkowska; Borys Wróbel; Grzegorz Węgrzyn; Alicja Węgrzyn

    2016-01-01

    A large scale analysis presented in this article focuses on biological and physiological variety of bacteriophages. A collection of 83 bacteriophages, isolated from urban sewage and able to propagate in cells of different bacterial hosts, has been obtained (60 infecting Escherichia coli, 10 infecting Pseudomonas aeruginosa, 4 infecting Salmonella enterica, 3 infecting Staphylococcus sciuri, and 6 infecting Enterococcus faecalis). High biological diversity of the collection is indicated by its...

  4. Effect of gamma irradiation and moisture on microbiological load of sewage sludge

    International Nuclear Information System (INIS)

    Al-Bachir, M.; Al-Adawi, M. A.; Shamma, M.

    2002-07-01

    Concentrated municipal sewage sludge, stored for 2, 4, and 6 months, with moisture content of 2, 20, 40, 60, and 80% were exposed to doses of 0, 1, 2, 3, 4, and 5 kGy in a 60 Co package irradiator. Immediately after irradiation, total microbial count, bacterial pathogens in sewage sludge was determined. Techno-economic feasibility of irradiated sewage according to the moisture content in sewage sludge and the needed irradiation dose to eliminate pathogens was evaluated. The results indicated that, all tested sewage sludge sample, bacterial pathogens including Enterobacter sp., Klebsiella sp., Salmonella sp., and e. coli, were detected. Used doses of gamma irradiation reduced the counts of microorganisms. D 1 0 of total count decreased with increasing the moisture level of sewage sludge. The lowest lethal dose for bacterial pathogens including Enterobacter sp., Klebsiella sp., Salmonella sp., and e. coli is over 5 kGy and 1 kGy in air dried and watered sludge with more than 40% sewage sludge respectively, for samples taken at 2, 4 and 6 months of storage. (author)

  5. Hydrochar from sewage sludge and urban wastes as a peat replacement in growing media preparation

    Science.gov (United States)

    Álvarez, Maria Luisa; Méndez, Ana; Paz-Ferreiro, Jorge; Soler-Rovira, Pedro; García-Gil, Juan Carlos; Plaza, César; Gascó, Gabriel

    2016-04-01

    Nowadays, there is an important trend in Europe for peat replacement with biochar in growing media formulation in order to reduce the environmental impact of peat exploitation. Hydrothermal carbonization (HTC) is a thermochemical process of converting organic feedstock into a high carbon rich solid product named hydrochar. It is performed in water mild temperature (180-260°C) under pressure conditions (2-6MPa) for 5-250 min. The reaction pressure is not controlled in the process and is autogenic with the saturation vapour pressure of water corresponding to the reaction temperature. In recent years, the possibility of subjecting organic wastes to HTC has attracted the scientific community attention due to their interesting advantages over other thermal treatments such as pyrolysis, torrefaction or gasification. The aim of the present paper is to study the possible use of two hydrochars produced by Ingelia (Spain) from sewage sludge and urban waste treatment as growing media material in horticulture. For this, thermal, chemical and hydrophysical properties were determined and compared with that of brown commercial peat.

  6. Thiol oxidation of hemolymph proteins in oysters Crassostrea brasiliana as markers of oxidative damage induced by urban sewage exposure.

    Science.gov (United States)

    Trevisan, Rafael; Flores-Nunes, Fabrício; Dolores, Euler S; Mattos, Jacó J; Piazza, Clei E; Sasaki, Sílvio T; Taniguchi, Satie; Montone, Rosalinda C; Bícego, Márcia C; Dos Reis, Isis M M; Zacchi, Flávia L; Othero, Bárbara N M; Bastolla, Camila L V; Mello, Danielle F; Fraga, Ana Paula M; Wendt, Nestor; Toledo-Silva, Guilherme; Razzera, Guilherme; Dafre, Alcir L; de Melo, Cláudio M R; Bianchini, Adalto; Marques, Maria R F; Bainy, Afonso C D

    2017-07-01

    Urban sewage is a concerning issue worldwide, threatening both wildlife and human health. The present study investigated protein oxidation in mangrove oysters (Crassostrea brasiliana) exposed to seawater from Balneário Camboriú, an important tourist destination in Brazil that is affected by urban sewage. Oysters were exposed for 24 h to seawater collected close to the Camboriú River (CAM1) or 1 km away (CAM2). Seawater from an aquaculture laboratory was used as a reference. Local sewage input was marked by higher levels of coliforms, nitrogen, and phosphorus in seawater, as well as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), linear alkylbenzenes (LABs), and fecal steroid in sediments at CAM1. Exposure of oysters to CAM1 caused marked bioaccumulation of LABs and decreased PAH and PCB concentrations after exposure to both CAM1 and CAM2. Protein thiol oxidation in gills, digestive gland, and hemolymph was evaluated. Lower levels of reduced protein thiols were detected in hemolymph from CAM1, and actin, segon, and dominin were identified as targets of protein thiol oxidation. Dominin susceptibility to oxidation was confirmed in vitro by exposure to peroxides and hypochlorous acid, and 2 cysteine residues were identified as potential sites of oxidation. Overall, these data indicate that urban sewage contamination in local waters has a toxic potential and that protein thiol oxidation in hemolymph could be a useful biomarker of oxidative stress in bivalves exposed to contaminants. Environ Toxicol Chem 2017;36:1833-1845. © 2016 SETAC. © 2016 SETAC.

  7. Occurrence of quaternary ammonium compounds (QACs) and their application as a tracer for sewage derived pollution in urban estuarine sediments

    International Nuclear Information System (INIS)

    Li, Xiaolin; Luo, Xiaojun; Mai, Bixian; Liu, Jingqin; Chen, Li; Lin, Shanshan

    2014-01-01

    Particle reactive organic contaminants in estuarine sediments can lead to various environmental problems affecting ecosystem and public health. In this study, the occurrence and homologous distribution pattern of quaternary ammonium compounds (QACs) in the surficial sediments collected from the Pearl River Estuary (PRE), China were examined along with polychlorinated biphenyls (PCBs) and polybrominated diphenylethers (PBDEs). The composition pattern of the QACs was found to be uniform in most of the sediments analyzed throughout the PRE, and the average composition pattern was identical to that determined in the sewage sludge from Guangzhou, the biggest city in the PRE. Dialkyldimethylammonium compounds, the most abundant type of QACs, positively correlated to the total concentrations of PCBs and PBDEs in most of the sediments with similar composition patterns. Therefore, the QACs are proposed as potential tracers to evaluate the transport of sewage-derived pollution in estuarine environments. -- Highlights: • Analysis method is developed for quaternary ammonium compounds (QACs) in sediment. • Occurrence of QACs is observed in the Pearl River Estuary, China for the first time. • QACs are proposed to be a tracer for sewage derived pollution in estuarine sediment. -- QACs were found to be present in the estuarine sediments in China for the first time and proposed as potential tracers for sewage-derived pollution in urban estuary

  8. Adsorption of phosphate from aqueous solutions and sewage using zirconium loaded okara (ZLO): Fixed-bed column study

    International Nuclear Information System (INIS)

    Nguyen, T.A.H.; Ngo, H.H.; Guo, W.S.; Pham, T.Q.; Li, F.M.; Nguyen, T.V.; Bui, X.T.

    2015-01-01

    This study explores the potential of removing phosphorus from aqueous solutions and sewage by Zr(IV)-loaded okara (ZLO) in the fixed-bed column. Soybean residue (okara) was impregnated with 0.25 M Zr(IV) solution to prepare active binding sites for phosphate. The effect of several factors, including flow rate, bed height, initial phosphorus concentration, pH and adsorbent particle size on the performance of ZLO was examined. The maximum dynamic adsorption capacity of ZLO for phosphorus was estimated to be 16.43 mg/g. Breakthrough curve modeling indicated that Adams–Bohart model and Thomas model fitted the experimental data better than Yoon–Nelson model. After treatment with ZLO packed bed column, the effluent could meet the discharge standard for phosphorus in Australia. Successful desorption and regeneration were achieved with 0.2 NaOH and 0.1 HCl, respectively. The results prove that ZLO can be used as a promising phosphorus adsorbent in the dynamic adsorption system. - Highlights: • Dynamic adsorption of P from water and wastewater by Zr(IV)-loaded okara was tested. • Effects of column design parameters on the adsorption performance were investigated. • The dynamic adsorption capacity of Zr(IV)-loaded okara for P was reasonably high. • The spent column was effectively regenerated with 0.2 M NaOH followed by 0.1 M HCl. • Zr(IV)-loaded okara column was efficient in eliminating P from municipal sewage

  9. Adsorption of phosphate from aqueous solutions and sewage using zirconium loaded okara (ZLO): Fixed-bed column study

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T.A.H. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Ngo, H.H., E-mail: ngohuuhao121@gmail.com [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Guo, W.S. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Pham, T.Q. [Faculty of Geography, University of Science, Vietnam National University, Hanoi (Viet Nam); Li, F.M. [College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100 (China); Nguyen, T.V. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Bui, X.T. [Environmental Engineering and Management Research Group, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology-Vietnam National University, Ho Chi Minh City (Viet Nam)

    2015-08-01

    This study explores the potential of removing phosphorus from aqueous solutions and sewage by Zr(IV)-loaded okara (ZLO) in the fixed-bed column. Soybean residue (okara) was impregnated with 0.25 M Zr(IV) solution to prepare active binding sites for phosphate. The effect of several factors, including flow rate, bed height, initial phosphorus concentration, pH and adsorbent particle size on the performance of ZLO was examined. The maximum dynamic adsorption capacity of ZLO for phosphorus was estimated to be 16.43 mg/g. Breakthrough curve modeling indicated that Adams–Bohart model and Thomas model fitted the experimental data better than Yoon–Nelson model. After treatment with ZLO packed bed column, the effluent could meet the discharge standard for phosphorus in Australia. Successful desorption and regeneration were achieved with 0.2 NaOH and 0.1 HCl, respectively. The results prove that ZLO can be used as a promising phosphorus adsorbent in the dynamic adsorption system. - Highlights: • Dynamic adsorption of P from water and wastewater by Zr(IV)-loaded okara was tested. • Effects of column design parameters on the adsorption performance were investigated. • The dynamic adsorption capacity of Zr(IV)-loaded okara for P was reasonably high. • The spent column was effectively regenerated with 0.2 M NaOH followed by 0.1 M HCl. • Zr(IV)-loaded okara column was efficient in eliminating P from municipal sewage.

  10. Sewage pollution in urban stormwater runoff as evident from the widespread presence of multiple microbial and chemical source tracking markers.

    Science.gov (United States)

    Sidhu, J P S; Ahmed, W; Gernjak, W; Aryal, R; McCarthy, D; Palmer, A; Kolotelo, P; Toze, S

    2013-10-01

    The concurrence of human sewage contamination in urban stormwater runoff (n=23) from six urban catchments across Australia was assessed by using both microbial source tracking (MST) and chemical source tracking (CST) markers. Out of 23 stormwater samples human adenovirus (HAv), human polyomavirus (HPv) and the sewage-associated markers; Methanobrevibacter smithii nifH and Bacteroides HF183 were detected in 91%, 56%, 43% and 96% of samples, respectively. Similarly, CST markers paracetamol (87%), salicylic acid (78%) acesulfame (96%) and caffeine (91%) were frequently detected. Twenty one samples (91%) were positive for six to eight sewage related MST and CST markers and remaining two samples were positive for five and four markers, respectively. A very good consensus (>91%) observed between the concurrence of the HF183, HAv, acesulfame and caffeine suggests good predictability of the presence of HAv in samples positive for one of the three markers. High prevalence of HAv (91%) also suggests that other enteric viruses may also be present in the stormwater samples which may pose significant health risks. This study underscores the benefits of employing a set of MST and CST markers which could include monitoring for HF183, adenovirus, caffeine and paracetamol to accurately detect human sewage contamination along with credible information on the presence of human enteric viruses, which could be used for more reliable public health risk assessments. Based on the results obtained in this study, it is recommended that some degree of treatment of captured stormwater would be required if it were to be used for non-potable purposes. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  11. The effect of sewage urban and industrial sludge on the development of wheat and colza

    Science.gov (United States)

    Lasoued, Najla; Bilal, Essaid; Rejeb, Saloua; Guénole-Bilal, Issam; Rejeb, Nejib

    2013-04-01

    The main objective of this study is to evaluate the effect of two types of sludge from sewage treatment urban and industrial plants on the wheat and colza. These sludge is made at different doses (5, 25, 50 and 100 t / ha). We are therefore interested in the growth and absorption of heavy metals by plants and follow the fate of the latter in the ground to prevent pollution events and toxicity. The soil is characterized by an alkaline pH; conductivity ranging from 1.06 to 1.52mmho/cm resulting low salinity and soil saturation is between 30.4 and 31.8ml/100g. The sand is the most representative size fraction in this soil which is a sandy loam soil texture. The percentages of limestone in the different horizons are less than 5% so it is a non-calcareous soil, with organic matter content very low. Contents of total nitrogen are relatively low. The C/N ratio is about 7 at the first horizon (0-10cm) indicates that organic matter will be quickly mineralized. The mean levels of heavy metals found in the soil are organized in the following order: Fe >> Mn> Zn> Pb> Cu> Ni> Co> Cd mean concentrations of heavy metals introduced by the sludge. With the addition of sludge, there is a parallel increase in the number of ears and an increased number of grains per m². The ears and grains also increases with increasing dose of sludge, whatever the type of sludge made. The increase in the number of grains with the addition of sludge has the consequence of decrease in PMG this can be explained by the decrease in weight and grain quality response to stress. The numbers of feet of wheat increases dice the contribution of 5t/ha sludge, this increase is more pronounced with the addition of urban sludge. The leaf area increases with the contribution of sludge as well as for urban or industrial sludge's. The leaf surface of this crop varies between 15.77cm2 of the oldest leaf to 3.78cm2 for the youngest leaf in the control soil. The leaf surface increases by 10cm² for 5BI and 11cm² 5BU

  12. Challenge of urban sewage disposal in a karst region: Mérida, Yucátan, Mexico

    Science.gov (United States)

    Perry, E. C.; Villasuso, M.

    2013-05-01

    Four hydrogeologic factors influence urban sewage management on the northern Yucátan (Mexico) Peninsula: 1) lack of rivers capable of transporting and/or oxidizing sewage, 2) near-surface flat-lying, porous, permeable limestone and dolomite with shallow layers of variable permeability but without major subsurface aquitards, 3) rapid groundwater transmission, penetration of seawater inland beneath a fresh water lens, and a flat water table only a few meters below land surface and controlled by sea level, 4) near absence of soil cover. Mérida, Yucátan (population approaching one million, approximately the world's 450th most populous city) has no central sewage system. The water table beneath the city is consistently only 7-9 m below land surface, and the 40 m-thick fresh water lens, which is the sole source of municipal, industrial, and agricultural water, directly overlies a marine intrusion of modified seawater composition. The old city has an estimated 130,000 drains feeding untreated household waste directly into the permeable karst aquifer. Numerous storm drains send street runoff directly to the aquifer. In addition, industries, hotels, and some subdivisions have unmonitored injection wells that pump untreated wastewater into the underlying saline intrusion. Some injection wells have flow problems possibly because of low aquifer permeability within the saline intrusion. Deep injection is also problematic because density contrast with saline intrusion water can produce a gravity imbalance, and high sulfate water can react with organic waste to produce H2S. Some city water supply wells are reportedly affected by inflation of the water table beneath the city, by local upconing of saline water, and by nitrate contamination. Paradoxically, Mérida with an abundant, easily contaminated source of fresh water, lacks streams to transport sewage off-site, and thus shares some water supply/sewage treatment problems with cities in arid regions. Recently, compact

  13. Assessing the impact of releases of radionuclides into sewage systems in urban environment - simulation, modelling and experimental studies - LUCIA

    International Nuclear Information System (INIS)

    Sundelll-Bergman, S.; Avila, R.; Cruz, I. de la; Xu, S.; Puhakainen, M.; Heikkinene, T.; Rahola, T.; Hosseini, A.; Nielsen, Sven; Sigurgeirsson, M.

    2009-06-01

    This report summarises the findings of a project on assessing the impact of releases of radionuclides into sewage systems and was established to provide more knowledge and suitable tools for emergency preparedness purposes in urban areas. It was known that the design of sewage plants, and their wastewater treatments, is rather similar between the Nordic countries. One sewage plant in each of the five Nordic countries was selected for assessing the impact of radionuclide releases from hospitals into their sewerage systems. Measurements and model predictions of dose assessments to different potentially exposed members of the public were carried out. The results from the dose assessments indicate that in case of routine releases annual doses to the three hypothetical groups of individuals are most likely insignificant. Estimated doses for workers are below 10 μSv/y, for the two studied radionuclides 99mTc and 131I. If uncertainties in the predictions of activity concentrations in sludge are considered, then the probability of obtaining doses above 10 μSv/y may not be insignificant. The models and approaches developed can also be applied in case of accidental releases. A laboratory inter-comparison exercise was also organised to compare analytical results across the laboratories participating in the project, using both 131I, dominating man-made radionuclide in sewage systems due to the medical use. A process oriented model of the biological treatment is also proposed in the report that does not require as much input data as for the LUCIA model. This model is a combination of a simplified well known Activated Sludge Model No.1 (Henze, 1987) and the Kd concept used in the LUCIA model. The simplified model is able to estimate the concentrations and the retention time of the sludge in different parts of the treatment plant, which in turn, can be used as a tool for the dose assessment purpose.filled by the activity. (au)

  14. Assessing the impact of releases of radionuclides into sewage systems in urban environment - simulation, modelling and experimental studies - LUCIA

    Energy Technology Data Exchange (ETDEWEB)

    Sundelll-Bergman, S. (Vattenfall Power Consultant, Stockholm (Sweden)); Avila, R.; Cruz, I. de la (Facilia AB, (Sweden)); Xu, S. (Swedish Radiation Safety Authority, (Sweden)); Puhakainen, M.; Heikkinene, T.; Rahola, T. (STUK (Finland)); Hosseini, A. (Norwegian Radiation Protection Authority (Norway)); Nielsen, Sven (Risoe National Laboratory for Sustainable Energy, DTU (Denmark)); Sigurgeirsson, M. (Geislavarnir rikisins (Iceland))

    2009-06-15

    This report summarises the findings of a project on assessing the impact of releases of radionuclides into sewage systems and was established to provide more knowledge and suitable tools for emergency preparedness purposes in urban areas. It was known that the design of sewage plants, and their wastewater treatments, is rather similar between the Nordic countries. One sewage plant in each of the five Nordic countries was selected for assessing the impact of radionuclide releases from hospitals into their sewerage systems. Measurements and model predictions of dose assessments to different potentially exposed members of the public were carried out. The results from the dose assessments indicate that in case of routine releases annual doses to the three hypothetical groups of individuals are most likely insignificant. Estimated doses for workers are below 10 muSv/y, for the two studied radionuclides 99mTc and 131I. If uncertainties in the predictions of activity concentrations in sludge are considered, then the probability of obtaining doses above 10 muSv/y may not be insignificant. The models and approaches developed can also be applied in case of accidental releases. A laboratory inter-comparison exercise was also organised to compare analytical results across the laboratories participating in the project, using both 131I, dominating man-made radionuclide in sewage systems due to the medical use. A process oriented model of the biological treatment is also proposed in the report that does not require as much input data as for the LUCIA model. This model is a combination of a simplified well known Activated Sludge Model No.1 (Henze, 1987) and the Kd concept used in the LUCIA model. The simplified model is able to estimate the concentrations and the retention time of the sludge in different parts of the treatment plant, which in turn, can be used as a tool for the dose assessment purpose.filled by the activity. (au)

  15. The process of biosorption of heavy metals in bioreactors loaded with sanitary sewage sludge

    Directory of Open Access Journals (Sweden)

    A. J. Morais Barros

    2006-06-01

    Full Text Available This work on the process of biosorption of nickel and chromium in an ascendant continuous-flow, fixed packed-bed bioreactor of sanitary sewage sludge was conducted in a search for solutions to the environmental problem caused by heavy metals. Analysis of the results demonstrated that the absorbent had an extraordinary capacity for biosorption of the heavy metals studied at about 9.0 pH of the effluent, with a removal percentage of over 90.0% for the two metals. Chemometric study results demonstrated that 20 days of the experimental system function were sufficient for achieving the maximum efficiency of sorption of the heavy metals studied by the sanitary sewage sludge employed.

  16. Source-specific sewage pollution detection in urban river waters using pharmaceuticals and personal care products as molecular indicators.

    Science.gov (United States)

    Kiguchi, Osamu; Sato, Go; Kobayashi, Takashi

    2016-11-01

    Source-specific elucidation of domestic sewage pollution caused by various effluent sources in an urban river water, as conducted for this study, demands knowledge of the relation between concentrations of pharmaceuticals and personal care products (PPCPs) as molecular indicators (caffeine, carbamazepine, triclosan) and water quality concentrations of total nitrogen (T-N) and total phosphorous (T-P). River water and wastewater samples from the Asahikawa River Basin in northern Japan were analyzed using derivatization-gas chromatography/mass spectrometry. Caffeine, used as an indicator of domestic sewage in the Asahikawa River Basin, was more ubiquitous than either carbamazepine or triclosan (92-100 %). Its concentration was higher than any target compound used to assess the basin: caffeine, caffeine concentrations detected in wastewater effluents and the strongly positive mutual linear correlation between caffeine and T-N or T-P (R 2  > 0.759) reflect the contribution of septic tank system effluents to the lower Asahikawa River Basin. Results of relative molecular indicators in combination with different molecular indicators (caffeine/carbamazepine and triclosan/carbamazepine) and cluster analysis better reflect the contribution of sewage than results obtained using concentrations of respective molecular indicators and cluster analysis. Relative molecular indicators used with water quality parameters (e.g., caffeine/T-N ratio) in this study provide results more clearly, relatively, and quantitatively than results obtained using molecular indicators alone. Moreover, the caffeine/T-N ratio reflects variations of caffeine flux from effluent sources. These results suggest strongly relative molecular indicators are also useful indicators, reflecting differences in spatial contributions of domestic sources for PPCPs in urban areas.

  17. Sedimentary records of sewage pollution using faecal markers in contrasting peri-urban shallow lakes

    Energy Technology Data Exchange (ETDEWEB)

    Vane, C.H., E-mail: chv@bgs.ac.uk [British Geological Survey, Keyworth, Nottingham, NG12 5GG (United Kingdom); Kim, A.W. [British Geological Survey, Keyworth, Nottingham, NG12 5GG (United Kingdom); McGowan, S. [School of Geography, University of Nottingham, University Park, Nottingham, NG7 2RD (United Kingdom); Leng, M.J.; Heaton, T.H.E.; Kendrick, C.P. [NERC Isotope Geosciences Laboratory, British Geological Survey, Keyworth, Nottingham, NG12 5GG (United Kingdom); Coombs, P. [British Geological Survey, Keyworth, Nottingham, NG12 5GG (United Kingdom); Yang, H. [Environmental Change Research Centre, University College London, WC1 6BT (United Kingdom); Swann, G.E.A. [NERC Isotope Geosciences Laboratory, British Geological Survey, Keyworth, Nottingham, NG12 5GG (United Kingdom)

    2010-12-15

    Sewage contamination in shallow lake sediments is of concern because the pathogens, organic matter and nutrients contribute to the deterioration of the water-bodies' health and ecology. Sediment cores from three shallow lakes (Coneries, Church and Clifton Ponds) within Attenborough nature reserve located downstream of sewage treatment works were analysed for TOC, C/N, {delta}{sup 13}C, {delta}{sup 15}N, bacterial coliforms and faecal sterols. {sup 210}Pb and {sup 137}Cs activities were used to date the sediments. Elemental analysis suggests that the source of organic matter was algal and down profile changes in {delta}{sup 13}C indicate a possible decrease in productivity with time which could be due to improvements in sewage treatment. {delta}{sup 15}N for Coneries Pond are slightly higher than those observed in Church or Clifton and are consistent with a sewage-derived nitrate source which has been diluted by non-sewage sources of N. The similarity in {delta}{sup 15}N values (+ 12 per mille to + 10 per mille ) indicates that the three ponds were not entirely hydrologically isolated. Analysis by gas chromatography/mass spectrometry (GC/MS) reveals that Coneries Pond had sterol concentrations in the range 20 to 30 {mu}g/g (dry wt.), whereas, those from Clifton and Church Ponds were lower. The highest concentrations of the human-sourced sewage marker 5{beta}-coprostanol were observed in the top 40 cm of Coneries Pond with values up to 2.2 {mu}g/g. In contrast, Church and Clifton Pond sediments contain only trace amounts throughout. Down-profile comparison of 5{beta}-coprostanol/cholesterol, 5{beta}-coprostanol/(5{beta}-coprostanol + 5{alpha}-cholestanol) and 5{beta}-epicoprostanol/coprostanol as well as 5{alpha}-cholestanol/cholesterol suggests that Coneries Pond has received appreciable amounts of faecal contamination. Examination of 5{beta}-stigmastanol (marker for herbivorous/ruminant animals) down core concentrations suggests a recent decrease in manure

  18. Phosphorus availability to ryegrass from urban sewage sludges assessed by isotopic labeling and dilution technique, effect of irradiation

    International Nuclear Information System (INIS)

    El-Motaium, R.A.; Morel, C.

    2007-01-01

    Urban sewage sludge are widely used as alternative P input because of their high P content. Irradiation of sewage sludge is developed in Egypt to make safe spreading of sludge on agricultural fields. Five sludges were sampled from representative urban wastewater treatment plants located in Cairo, Egypt. Sub samples were irradiated using gamma radiation at 6 KGy dose. A pot experiment was conducted under plastic greenhouse using sandy P-deficient soil. The soil was homogeneously labelled with a radioactive solution of carrier-free 32 PO 4 (about 3 MBq kg / soil) to determine the contribution of the different sources of P in plant nutrition. Sludges were applied at 50 mg P/ kg soil. In addition, a control treatment was also carried out to analyze sludge P availability in comparison to a water soluble mineral fertilizer, i.e. 50 mg P/kg soil was applied as commercial monocalcium phosphate (SSP). A reference treatment was included without any P application but the radioactive solution was added. One gram of ryegrass seeds (Lolium multiflorium) was sown in each pot. The aerial parts of the ryegrass were harvested four times, every 3 weeks. Analysis of all harvests included 32 P and total P content was used to determine the respective contribution of soil and sludge to plant P nutrition and the plant available P (L value) using the isotopic dilution principle. The ratio of radioactive P to non-radioactive P, i.e. isotopic composition, was calculated. The total P content in the different urban sewage sludge was ranged from 6.2 to 13.8 g P/ kg and affected by irradiation. Because the soil was extremely P deficient (L value=0.3 mg P/ kg soil), P derived from seeds represented 99% of the P taken up when no P was applied and 87% when applying 50 mg P-SSP/ kg. After correcting the contribution of ryegrass seeds, sludge P contributed by 98% to plant nutrition and 7.2% of the applied P was recovered. The sludge type and irradiation factors did not significantly affect sludge P

  19. Seasonal variations and resilience of bacterial communities in a sewage polluted urban river.

    Directory of Open Access Journals (Sweden)

    Tamara García-Armisen

    Full Text Available The Zenne River in Brussels (Belgium and effluents of the two wastewater treatment plants (WWTPs of Brussels were chosen to assess the impact of disturbance on bacterial community composition (BCC of an urban river. Organic matters, nutrients load and oxygen concentration fluctuated highly along the river and over time because of WWTPs discharge. Tag pyrosequencing of bacterial 16S rRNA genes revealed the significant effect of seasonality on the richness, the bacterial diversity (Shannon index and BCC. The major grouping: -winter/fall samples versus spring/summer samples- could be associated with fluctuations of in situ bacterial activities (dissolved and particulate organic carbon biodegradation associated with oxygen consumption and N transformation. BCC of the samples collected upstream from the WWTPs discharge were significantly different from BCC of downstream samples and WWTPs effluents, while no significant difference was found between BCC of WWTPs effluents and the downstream samples as revealed by ANOSIM. Analysis per season showed that allochthonous bacteria brought by WWTPs effluents triggered the changes in community composition, eventually followed by rapid post-disturbance return to the original composition as observed in April (resilience, whereas community composition remained altered after the perturbation by WWTPs effluents in the other seasons.

  20. Effect of electron beam irradiation on bacterial and Ascaris ova loads and volatile organic compounds in municipal sewage sludge

    International Nuclear Information System (INIS)

    Engohang-Ndong, Jean; Uribe, R.M.; Gregory, Roger; Gangoda, Mahinda; Nickelsen, Mike G.; Loar, Philip

    2015-01-01

    Wastewater treatment plants produce large amounts of biosolids that can be utilized for land applications. However, prior to their use, these biosolids must be treated to eliminate risks of infections and to reduce upsetting odors. In this study, microbiological and chemical analyzes were performed before and after treatment of sewage sludge with 3 MeV of an electron beam accelerator in a pilot processing plant. Thus, we determined that dose 4.5 kGy was required to reduce fecal coliform counts to safe levels for land applications of sludge while, 14.5 kGy was necessary to decrease Ascaris ova counts to safe levels. Furthermore, at low doses, electron beam irradiation showed little effect on the concentrations of volatile organic compounds, while some increase were recorded at high doses. The concentration of dimethyl sulfide was reduced by 50–70% at irradiation doses of 25.7 kGy and 30.7 kGy respectively. By contrast, electron beam irradiation increased dimethyl disulfide concentrations. We also showed that electron beam treatment was less energy-consuming with shorter processing times than conventional techniques used to decontaminate sludge. Hence opening new avenues for large urban agglomerations to save money and time when treating biosolids for land application. - Highlights: • Use of electron beam irradiation for the treatment of municipal sewage sludge. • Irradiation at 4.5 kGy is required to eliminate risks of bacterial infection. • Irradiation at 14.5 kGy is required to eliminate risks of helminth infection. • Electron beam technology is not effective for controlling volatile organic compounds. • Electron beam treatment of sludge is less expensive than traditional techniques

  1. Lachnospiraceae and Bacteroidales Alternative Fecal Indicators Reveal Chronic Human Sewage Contamination in an Urban Harbor▿†

    Science.gov (United States)

    Newton, Ryan J.; VandeWalle, Jessica L.; Borchardt, Mark A.; Gorelick, Marc H.; McLellan, Sandra L.

    2011-01-01

    detect sewage compared to general indicators, and the relationship to a human pathogen group suggests that the use of these alternative indicators will improve assessments for human health risks in urban waters. PMID:21803887

  2. Multiple lines of evidence to identify sewage as the cause of water quality impairment in an urbanized tropical watershed.

    Science.gov (United States)

    Kirs, Marek; Kisand, Veljo; Wong, Mayee; Caffaro-Filho, Roberto A; Moravcik, Philip; Harwood, Valerie J; Yoneyama, Bunnie; Fujioka, Roger S

    2017-06-01

    Indicator bacteria, which are conventionally used to evaluate recreational water quality, can originate from various non-human enteric and extra-enteric sources, hence they may not be indicative of human health risk nor do they provide information on the sources of contamination. In this study we utilized traditional (enterococci and Escherichia coli) and alternative (Clostridium perfringens) indicator bacteria, F + -specific coliphage, molecular markers for microorganisms associated with human sewage (human-associated Bacteroides and polyomaviruses), and microbial community analysis tools (16S rRNA gene fragment amplicon sequencing), to identify and evaluate human sewage-related impact in the Manoa watershed in Honolulu, Hawaii. Elevated concentrations of enterococci (geometric mean ranging from 1604 to 2575 CFU 100 mL -1 ) and C. perfringens (45-77 CFU 100 mL -1 ) indicated impairment of the urbanized section of the stream, while indicator bacteria concentrations decreased downstream in the tidally influenced Ala Wai Canal. The threshold values triggering water quality violation notifications in Hawaii were exceeded in 33.3-75.0% of samples collected at sites in the urbanized section of Manoa Stream, but were not exceeded in any of the samples collected at an upstream site located in a forested area. Correlation between indicator bacteria concentrations and rainfall amounts was weak to moderate but significant (E. coli R = 0.251, P = 0.009; enterococci R = 0.369, P watershed, it was lower in the impaired section. Leaking sewer systems and illegal cross-connections are implicated in the impairment of the watershed, hence both the sewer and the storm water lines should be routinely inspected. Collectively, our data suggest that information derived from the analysis of microbial communities complements current marker-based microbial source tracking techniques and environmental monitoring programs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. From municipal sewage to drinking water: fate and removal of pharmaceutical residues in the aquatic environment in urban areas.

    Science.gov (United States)

    Heberer, Th; Reddersen, K; Mechlinski, A

    2002-01-01

    Recently, the occurrence and fate of pharmaceutically active compounds (PhACs) in the aquatic environment was recognized as one of the emerging issues in environmental chemistry and as a matter of public concern. Residues of PhACs have been found as contaminants in sewage, surface, and ground- and drinking water samples. Since June 2000, a new long-term monitoring program of sewage, surface, ground- and drinking water has been carried out in Berlin, Germany. Samples, collected periodically from selected sites in the Berlin area, are investigated for residues of PhACs and related contaminants. The purpose of this monitoring is to investigate these compounds over a long time period to get more reliable data on their occurrence and fate in the different aquatic compartments. Moreover, the surface water investigations allow the calculation of season-dependent contaminant loads in the Berlin waters. In the course of the monitoring program, PhACs and some other polar compounds were detected at concentrations up to the microg/L-level in all compartments of the Berlin water cycle. The monitoring is accompanied and supported by several other investigations such as laboratory column experiments and studies on bank filtration and drinking water treatment using conventional or membrane filtration techniques.

  4. [Estimation of urban non-point source pollution loading and its factor analysis in the Pearl River Delta].

    Science.gov (United States)

    Liao, Yi-Shan; Zhuo, Mu-Ning; Li, Ding-Qiang; Guo, Tai-Long

    2013-08-01

    In the Pearl Delta region, urban rivers have been seriously polluted, and the input of non-point source pollution materials, such as chemical oxygen demand (COD), into rivers cannot be neglected. During 2009-2010, the water qualities at eight different catchments in the Fenjiang River of Foshan city were monitored, and the COD loads for eight rivulet sewages were calculated in respect of different rainfall conditions. Interesting results were concluded in our paper. The rainfall and landuse type played important roles in the COD loading, with greater influence of rainfall than landuse type. Consequently, a COD loading formula was constructed that was defined as a function of runoff and landuse type that were derived SCS model and land use map. Loading of COD could be evaluated and predicted with the constructed formula. The mean simulation accuracy for single rainfall event was 75.51%. Long-term simulation accuracy was better than that of single rainfall. In 2009, the estimated COD loading and its loading intensity were 8 053 t and 339 kg x (hm2 x a)(-1), and the industrial land was regarded as the main source of COD pollution area. The severe non-point source pollution such as COD in Fenjiang River must be paid more attention in the future.

  5. Determination of phosphorus in urban sewage sludge using the isotopic exchange kinetics method

    International Nuclear Information System (INIS)

    Rojas de Tramontini, Susana; Barbaro, Nestor O.; Lopez, Silvia C.

    1999-01-01

    The aim of this work was to assess the differences among soil available P, the use by the plants of sludge P, and of a water soluble fertilizer (Ca(H 2 PO 4 ) 2 ) P, using isotopic exchange kinetics methods. The sludge was provided by the Sewage Sludge Treatment Plant of Tucuman City, Argentina. The isotopic exchange kinetics experiment, in which the fate of carrier free 32 PO 4 added to the soil solution at a steady state was studied, gives information on soil P exchangeability. The experiment was carried out in the laboratory, where sewage sludge and water soluble fertilizer were added to soil samples taken at a depth of 0-25 and 25-40 cm. Changes in the soil P isotopically exchangeable within 1 minute measurements in the soil with sludge and in the soil with water soluble fertilizer showed that the 0-25 cm deep soil samples had a low P sorption capacity (r1 /R values were low). The sludge had high total and organic P, but the P in the soil solution was lower than the P provided by the water soluble fertilizer. Therefore, despite its higher total P content, this sludge contained slow available forms of P

  6. Enantiomer profiling of high loads of amphetamine and MDMA in communal sewage: a Dutch perspective

    NARCIS (Netherlands)

    Emke, E.; Evans, S; Kasprzyk-Hordern, B.; de Voogt, P.

    2014-01-01

    Analysis of wastewater with an aim of community-wide estimation of drug use is a new and very promising approach. Until now it was very difficult to determine if mass loads of studied drugs were actually originating from consumption, or disposal of unused drugs or production waste. This uncertainty

  7. Decreasing the Thermal Load on the Environment with the Help of Thermal Pumps in the Sewage Treatment System

    Science.gov (United States)

    Lozovetskii, V. V.; Lebedev, V. V.; Cherkina, V. M.; Ivanchuk, M. S.

    2018-05-01

    We propose designs for practical use of residual heat of sewage by means of thermal-pump transformation of thermal energy in plants operating on inverse Rankine and Lorentz cycles, as well as a method for sewage heat removal in drainage canals of water removal systems based on the application of double-pipe heat exchangers known as Field tubes.

  8. Property of filler-loaded magnetic ferrite from plastic waste bottle used to treat municipal domestic sewage.

    Science.gov (United States)

    Zhao, Ru-Jin; Gong, Li-Ying; Zhu, Hai-Dong; Liu, Qiao; Xu, Li-Xia; Lu, Lu; Yang, Qi-Zhi

    2018-06-01

    The present work investigates the properties of self-made magnetic filler from plastic waste bottle and explores a new technology approach of waste plastic resource utilization. The magnetic filler was prepared by air plasma modification and loading magnetic ferrite on the plastic strip from waste plastic bottle. The surface properties of magnetic filler were characterized by Atomic Force Microscope (AFM), contact angle system and Fourier Transform Infrared (FTIR). AFM images of original and modified plastic strip showed that low-temperature plasma treatment markedly increased the surface roughness of plastic strip. The mean roughness (Ra) of plastic strip rose from 1.116 to 5.024 nm. FTIR spectra indicated that a lot of polar oxygenic groups were introduced onto the surface of plastic by plasma modification. Modification by low-temperature plasma increased the hydrophilicity of plastic strip surface. When treatment time is 40 s, water contact angle of plastic strip surface reduced from 78.2° of original plastic strip to 25.3°. When used in bioreactor, magnetic filler had very favorable microenvironment for microorganism growth. Magnetic filler was more efficient for removing chemical oxygen demand (COD) and [Formula: see text] in sewage than nonmagnetic filler. The resource utilization of plastic wastes will become reality if the magnetic filler is applied widely.

  9. Fate, partitioning, and mass loading of polybrominated diphenyl ethers (PBDEs) during the treatment processing of municipal sewage.

    Science.gov (United States)

    Song, Min; Chu, Shaogang; Letcher, Robert J; Seth, Rajesh

    2006-10-15

    Sewage treatment plant (STP) effluents are likely a major source of contamination for PBDEs, especially in the receiving water bodies of local aquatic environments surrounding the location of these discharges. Congeners of the pentaBDE mixture, 2,2,',4,4'-tetrabromodiphenyl ether (BDE47), 2,2,',4,4',5-pentabromodiphenyl ether (BDE99), 2,2,',4,4',6-pentabromodiphenyl ether (BDE100), 2,2,',4,4',5,5'-hexabromodiphenyl ether (BDE153), and 2,2,',4,4',5,6'-hexabromodiphenyl ether (BDE154), are of great environmental concern in North America due to their persistence, potential for bioaccumulation, and >97% use of the global production of the mixture in the region. Detailed characterization of the distribution of eight PBDE congeners (2,4,4'-tribromoDE (BDE28) and BDE47, 99, 100, 138, 153, 154, and 183) was carried out at five sites along the treatment process at an activated sludge-type secondary treatment municipal STP facility. PentaBDE mixture congeners, sigma5PBDE (sum of BDE47, 99, 100, 153, and 154) accounted for >98% of the total (sigma 8) PBDE concentration at all sites, with over 80% of the composition being BDE47 and BDE99. Presence of dissolved organic matter affected the mobility of PBDEs during the initial stages of the treatment process. About 9% of the influent mass of sigma5PBDE to the facility is estimated to be discharged into the Little River (leading to the Detroit River) with the final effluent, resulting in an estimated mass loading of approximately 0.7 kg/year. The total mass loading of sigma5PBDE to the Detroit River is expected to be much larger as effluent from this facility accounts for <10% of the total STP discharges to the river.

  10. Hybrid cogeneration system fueled with biogas obtained from urban sewage water

    Directory of Open Access Journals (Sweden)

    Laurentiu Călin

    2008-10-01

    Full Text Available When treating urban waste water, a large quantity of sludge is produced. This sludge may by used in fermentation tanks to obtain biogas with medium to high levels of methane, which is ideal for electric energy and heat production. The aim of this paper is to develop a theoretical study regarding the use of biogas in power and heat generation modules. Biogas can be used for fueling internal combustion engines or fuel cells, which in turn generate electricity. Waste heat contained in the exhaust gas can be recovered in order to maximize efficiency. The theoretical study presented in this paper evaluates electrical and overall efficiency of a biogas production installation inside an urban waste water treatment.

  11. Grey water characterisation and pollutant loads in an urban slum

    International Nuclear Information System (INIS)

    Katukiza, A. Y.; Ronteltap, M.; Niwagaba, C. B.; Kansiime, F.; Lens, P. N. L.

    2015-01-01

    On-site sanitation provisions in urban slums rarely prioritise grey water management, yet it forms the largest fraction of wastewater. This study was carried out to characterise grey water and quantify its pollutant loads in Bwaise III (Uganda) and to provide data for grey water management in urban slums of developing countries. Samples were collected for analysis from ten representative households as well as from four tertiary drains and the main drainage channel for 7 months in two dry seasons. Grey water production was found to comprise 85 % of the domestic water consumption. The chemical oxygen demand concentration in the grey water generated by laundry, in the kitchen and in the bathroom was 9,225 ± 1,200 mg L-1, 71,250 ± 1,011 mg L-1 and 4,675 ± 750 mg L-1, while the BOD5 (biochemical oxygen demand) to COD ratio was 0.24 ± 0.05, 0.33 ± 0.08 and 0.31 ± 0.07, respectively. The maximum concentration of Escherichia coli and total coliforms was 2.05 9 107 cfu (100 mL)-1 and 1.75 9 108 cfu (100 mL)-1, respectively, in grey water from the bathroom, while that of Salmonella spp. was 7.32 9 106 cfu (100 mL)-1 from laundry. Analysis of variance (ANOVA) showed a significant difference in the concentration of COD, total suspended solids, total organic carbon, dissolved organic carbon, total phosphorus, sodium adsorption ratio, oil and grease, and Salmonella spp. in grey water from laundry, bathroom and kitchen (p/0.05). The high loads of COD ([500 kg day-1), total suspended solids ([200 kg day-1), nutrients (8.3 kg TKN day-1 and 1.4 kg total phosphorus day-1) and microorganisms (106 to 109 cfu c-1 day-1) originating from grey water in Bwaise III show that grey water poses a threat to the environment and a risk to human health in urban slums. Therefore, there is a need to prioritise grey water treatment in urban slums of developing countries to achieve adequate sanitation.

  12. Saline sewage treatment and source separation of urine for more sustainable urban water management.

    Science.gov (United States)

    Ekama, G A; Wilsenach, J A; Chen, G H

    2011-01-01

    While energy consumption and its associated carbon emission should be minimized in wastewater treatment, it has a much lower priority than human and environmental health, which are both closely related to efficient water quality management. So conservation of surface water quality and quantity are more important for sustainable development than green house gas (GHG) emissions per se. In this paper, two urban water management strategies to conserve fresh water quality and quantity are considered: (1) source separation of urine for improved water quality and (2) saline (e.g. sea) water toilet flushing for reduced fresh water consumption in coastal and mining cities. The former holds promise for simpler and shorter sludge age activated sludge wastewater treatment plants (no nitrification and denitrification), nutrient (Mg, K, P) recovery and improved effluent quality (reduced endocrine disruptor and environmental oestrogen concentrations) and the latter for significantly reduced fresh water consumption, sludge production and oxygen demand (through using anaerobic bioprocesses) and hence energy consumption. Combining source separation of urine and saline water toilet flushing can reduce sewer crown corrosion and reduce effluent P concentrations. To realize the advantages of these two approaches will require significant urban water management changes in that both need dual (fresh and saline) water distribution and (yellow and grey/brown) wastewater collection systems. While considerable work is still required to evaluate these new approaches and quantify their advantages and disadvantages, it would appear that the investment for dual water distribution and wastewater collection systems may be worth making to unlock their benefits for more sustainable urban development.

  13. Nowcasting of rainfall and of combined sewage flow in urban drainage systems.

    Science.gov (United States)

    Achleitner, Stefan; Fach, Stefan; Einfalt, Thomas; Rauch, Wolfgang

    2009-01-01

    Nowcasting of rainfall may be used additionally to online rain measurements to optimize the operation of urban drainage systems. Uncertainties quoted for the rain volume are in the range of 5% to 10% mean square error (MSE), where for rain intensities 45% to 75% MSE are noted. For larger forecast periods up to 3 hours, the uncertainties will increase up to some hundred percents. Combined with the growing number of real time control concepts in sewer systems, rainfall forecast is used more and more in urban drainage systems. Therefore it is of interest how the uncertainties influence the final evaluation of a defined objective function. Uncertainty levels associated with the forecast itself are not necessarily transferable to resulting uncertainties in the catchment's flow dynamics. The aim of this paper is to analyse forecasts of rainfall and specific sewer output variables. For this study the combined sewer system of the city of Linz in the northern part of Austria located on the Danube has been selected. The city itself represents a total area of 96 km2 with 39 municipalities connected. It was found that the available weather radar data leads to large deviations in the forecast for precipitation at forecast horizons larger than 90 minutes. The same is true for sewer variables such a CSO overflow for small sub-catchments. Although the results improve for larger spatial scales, acceptable levels at forecast horizons larger than 90 minutes are not reached.

  14. Runoff quality and pollution loadings from a tropical urban catchment.

    Science.gov (United States)

    Yusop, Z; Tan, L W; Ujang, Z; Mohamed, M; Nasir, K A

    2005-01-01

    Runoff quality draining from 17.14 km2 urban catchment in Johor Bahru, Malaysia, was analysed. The land-use consists of residential (30.3%), agricultural (27.3%), open space (27.9%), industrial (8.1%) and commercial (6.4%) areas. Three storm events were sampled in detail. These storms produced stormflow between 0.84 mm and 27.82 mm, and peakflow from 2.19 m3/s to 42.36 m3/s. Water quality showed marked variation during storms especially for TSS, BOD and COD with maximum concentrations of 778 mg/l, 135 mg/l and 358 mg/l, respectively. Concentrations of TOC, DOC, NH3-N, Fe and level of colour were also high. In general, the river quality is badly polluted and falls in Class V based on the Malaysian Interim National Water Quality Standards. Event Mean Concentrations (EMC) for various parameters varied considerably between storms. The largest storm produced higher EMC for TSS, NO3-N and SS whereas the smaller storms tend to register higher EMC for BOD, COD, NH3-N, TOC, Ca, K, Mg, Fe and Zn. Such variations could be explained in terms of pollutant availability and the effects of flushing and dilution. Based on a three-month average recurrence interval (ARI) of rainfall, the estimated event loadings (ton/ha) of TSS, BOD, COD, TOC, NH3-N and NO3-N were 0.055, 0.016, 0.012, 0.039, 0.010, 0.0007 and 0.0002, respectively. Heavy metals present in trace quantities. Storms with 3 months ARI could capture about 70% of the total annual loads of major pollutants.

  15. Autotrophic and heterotrophic nitrification-anoxic denitrification dominated the anoxic/oxic sewage treatment process during optimization for higher loading rate and energy savings.

    Science.gov (United States)

    Zhang, Xueyu; Zheng, Shaokui; Zhang, Hangyu; Duan, Shoupeng

    2018-04-30

    This study clarified the dominant nitrogen (N)-transformation pathway and the key ammonia-oxidizing microbial species at three loading levels during optimization of the anoxic/oxic (A/O) process for sewage treatment. Comprehensive N-transformation activity analysis showed that ammonia oxidization was performed predominantly by aerobic chemolithotrophic and heterotrophic ammonia oxidization, whereas N 2 production was performed primarily by anoxic denitrification in the anoxic unit. The abundances of ammonia-oxidizing bacteria (AOB), nitrite-oxidizing bacteria, and anaerobic AOB in activated sludge reflected their activities on the basis of high-throughput sequencing data. AOB amoA gene clone libraries revealed that the predominant AOB species in sludge samples shifted from Nitrosomonas europaea (61% at the normal loading level) to Nitrosomonas oligotropha (58% and 81% at the two higher loading levels). Following isolation and sequencing, the predominant culturable heterotrophic AOB in sludge shifted from Agrobacterium tumefaciens (42% at the normal loading level) to Acinetobacter johnsonii (52% at the highest loading level). Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Evaluation of triclosan and triclocarban at river basin scale using monitoring and modeling tools: implications for controlling of urban domestic sewage discharge.

    Science.gov (United States)

    Zhao, Jian-Liang; Zhang, Qian-Qian; Chen, Feng; Wang, Li; Ying, Guang-Guo; Liu, You-Sheng; Yang, Bin; Zhou, Li-Jun; Liu, Shan; Su, Hao-Chang; Zhang, Rui-Quan

    2013-01-01

    Triclosan (TCS) and triclocarban (TCC) are two commonly used personal care products. They may enter into aquatic environments after consumption and pose potential risks to aquatic organisms. We investigated the occurrence and fate of TCS and TCC in five large rivers (the Liao River, Hai River, Yellow River, Zhujiang River and Dongjiang River) in China, and compared the monitoring data with the predicted results from Level III fugacity modeling. TCS and TCC were detected in the five large rivers with the detection frequencies of 100% or close to 100% in surface water and sediments of almost every river. TCS and TCC were found at concentrations of up to 478 ng/L and 338 ng/L in surface water, and up to 1329 ng/g and 2723 ng/g in sediments. Cluster analysis indicated that the sites with higher concentrations were usually located in or near urban area. Meanwhile, principal component analysis also suggested that the mass inventories of TCS and TCC in water and sediment were significantly influenced by the factors such as the total or untreated urban domestic sewage discharge at river basin scale. The concentrations and mass inventories from the fugacity modeling were found at the same order of magnitude with the measured values, suggesting that the fugacity modeling can provide a useful tool for evaluating the fate of TCS and TCC in riverine environments. Both monitoring and modeling results indicated that the majority of mass inventories of TCS and TCC were stored into sediment, which could be a potential pollution source for river water. The wide presence of TCS and TCC in these large rivers of China implies that better controlling of urban domestic sewage discharge is needed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Twenty two years of sewage sludge marine disposal monitoring in the Eastern Mediterranean Sea: Impact on sediment quality and infauna and the response to load reduction.

    Science.gov (United States)

    Kress, N; Shoham-Frider, E; Galil, B S

    2016-09-15

    Effects of sewage sludge disposal on sediments and infauna are presented in a unique long-term (22years) data set from the Eastern Mediterranean. While organic carbon (Corg) and metals affected sediment quality in an area which size varied seasonally, the infauna exhibited seasonal "boom and bust" cycle. Metal concentrations declined following load reduction. However, Corg did not decrease and infaunal abundance, closely related to Corg, varied with changes in environmental forcing. Mild winters affected the infaunal populations at the heavily impacted stations, due to anoxic conditions. Planned cessation of disposal is estimated to reduce Corg and metal concentrations to pre-discharge levels. Yet the resettling biota is expected to differ significantly from the pre-discharge one and consist in large part of Erythraean non indigenous species. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. [Effect of antecedent dry weather period on urban storm runoff pollution load].

    Science.gov (United States)

    Li, Li-qing; Yin, Cheng-qing; Kong, Ling-li; He, Qing-ci

    2007-10-01

    Twelve storm events were surveyed at Shilipu catchment in Wuhan City through three-year monitoring regime. The flow discharges, total suspended solids (TSS), chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) in runoff were measured to study the mechanism of urban stormwater runoff pollution. The relationship between the event pollution load and the antecedent dry weather period was identified to discuss the influence of the urban surface sanitation management, operation of sewer pipe maintenance and rainfall characteristics on the urban stormwater runoff pollution. It was found that the antecedent dry weather period and runoff amount were the important determining factors in the generation of urban stormwater runoff pollution. The event pollution load was positively correlated to the antecedent dry weather period between two rainfall events (R2 = 0.95, p pollution loads. The best regression equation to estimate pollution load for storm events was developed based on the antecedent dry weather period and runoff depth. Source control including improving urban street sweeping activities and operation of sewer pipe maintenance should be made to reduce the amount of available pollutant over the dry days. It is important alternative to control urban stormwater runoff pollution for Hanyang District.

  19. An urban observatory for quantifying phosphorus and suspended solid loads in combined natural and stormwater conveyances.

    Science.gov (United States)

    Melcher, Anthony A; Horsburgh, Jeffery S

    2017-06-01

    Water quality in urban streams and stormwater systems is highly dynamic, both spatially and temporally, and can change drastically during storm events. Infrequent grab samples commonly collected for estimating pollutant loadings are insufficient to characterize water quality in many urban water systems. In situ water quality measurements are being used as surrogates for continuous pollutant load estimates; however, relatively few studies have tested the validity of surrogate indicators in urban stormwater conveyances. In this paper, we describe an observatory aimed at demonstrating the infrastructure required for surrogate monitoring in urban water systems and for capturing the dynamic behavior of stormwater-driven pollutant loads. We describe the instrumentation of multiple, autonomous water quality and quantity monitoring sites within an urban observatory. We also describe smart and adaptive sampling procedures implemented to improve data collection for developing surrogate relationships and for capturing the temporal and spatial variability of pollutant loading events in urban watersheds. Results show that the observatory is able to capture short-duration storm events within multiple catchments and, through inter-site communication, sampling efforts can be synchronized across multiple monitoring sites.

  20. Evaluation of the nitrogen load of the sludge liquor from the band filters of the sewage treatment plant of Pinedo (Valencia); Nitrogeno aportado por el licor del fango de los filtros banda a la linea de retorno en la EDAR de Pinedo (Valencia)

    Energy Technology Data Exchange (ETDEWEB)

    Bes Pia, A.; Mendoza Roca, J. A. [Universidad Politecnica de Valencia (Spain)

    2000-07-01

    The sludge treatment in a sewage treatment plant generates liquid effluents called sludge liquors that are pumped to the plant entrance. These effluents provide a pollution load that must be considered in the design of the sewage treatment plant, outstanding, all and above the nitrogen load produced by the sludge dewatering after its anaerobic digestion. In the present research the mentioned liquor is studied and characterized in order to determine the nitrogen load recirculated to the entrance of the old-established line of the Pinedo sewage treatment plant (Valencia). (Author) 3 refs.

  1. Analysis of the Impact of Urban Microclimate on Air Conditioning Load Control

    Directory of Open Access Journals (Sweden)

    Hu Xiaoqing

    2016-01-01

    Full Text Available Due to the presence of urban heat island effect (UHIE, high humidity and other urban microclimate, temperature of city central area rises. This causes that the actual air-conditioning energy consumption (ACEC in the urban central area is much higher than that in the suburbs. Load control of air-conditioners (ACs is considered to be equivalent to a power plant of the same capacity, and it can greatly reduce the system pressure to peak load shift. In this paper, a simplified second order transfer function control model of ACs is presented, and its parameters will be influenced by the ambient temperature and urban microclimate. The temperature is obtained by using the temperature inversion algorithm of the heat island effect. Then, the heat index is calculated by combining temperature and humidity. The ambient temperature index of urban central area is modified based on the above microclimate, and the second order linear time invariant model of aggregated ACs is upgraded to the linear time varying model. Furthermore, the consequent parameter changes of the second order transfer function model are studied and the influence of urban microclimate on AC load control is analyzed. The proposed method is verified on numerical examples

  2. Urban Saturated Power Load Analysis Based on a Novel Combined Forecasting Model

    Directory of Open Access Journals (Sweden)

    Huiru Zhao

    2015-03-01

    Full Text Available Analysis of urban saturated power loads is helpful to coordinate urban power grid construction and economic social development. There are two different kinds of forecasting models: the logistic curve model focuses on the growth law of the data itself, while the multi-dimensional forecasting model considers several influencing factors as the input variables. To improve forecasting performance, a novel combined forecasting model for saturated power load analysis was proposed in this paper, which combined the above two models. Meanwhile, the weights of these two models in the combined forecasting model were optimized by employing a fruit fly optimization algorithm. Using Hubei Province as the example, the effectiveness of the proposed combined forecasting model was verified, demonstrating a higher forecasting accuracy. The analysis result shows that the power load of Hubei Province will reach saturation in 2039, and the annual maximum power load will reach about 78,630 MW. The results obtained from this proposed hybrid urban saturated power load analysis model can serve as a reference for sustainable development for urban power grids, regional economies, and society at large.

  3. Influences of rainfall variables and antecedent discharge on urban effluent concentrations and loads in wet weather.

    Science.gov (United States)

    Xu, Zuxin; Xiong, Lijun; Li, Huaizheng; Liao, Zhengliang; Yin, Hailong; Wu, Jun; Xu, Jin; Chen, Hao

    2017-04-01

    For storm drainages inappropriately connected with sewage, wet weather discharge is a major factor that adversely affects receiving waters. A study of the wet weather influences of rainfall-discharge variables on storm drainages connected with sewage was conducted in the downtown Shanghai area (374 ha). Two indicators, event mean concentration (EMC) and event pollutant load per unit area (EPL), were used to describe the pollution discharge during 20 rain events. The study showed that the total rainfall and discharge volume were important factors that affect the EMCs and EPLs of the chemical oxygen demand, total phosphorus, and especially those of NH 4 + -N. The pollutant concentrations at the beginning of the discharge and the discharge period were also major factors that influence the EMCs of these three pollutants. Regression relationships between the rainfall-discharge variables and discharge volume/ EPLs (R 2 = 0.824-0.981) were stronger than the relationships between the rainfall-discharge variables and EMCs. These regression equations can be considered reliable in the system, with a relative validation error of less than ±10% for the discharge volume, and less than ±20% for the EPLs. The results presented in this paper provide guidance for effectively controlling pollution in similar storm drainages.

  4. Water-quality data for two surface coal mines reclaimed with alkaline waste or urban sewage sludge, Clarion County, Pennsylvania, May 1983 through November 1989

    Science.gov (United States)

    Dugas, D.L.; Cravotta, C.A.; Saad, D.A.

    1993-01-01

    Water-quality and other hydrologic data for two surface coal mines in Clarion County, Pa., were collected during 1983-89 as part of studies conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Environmental Resources. Water samples were collected from streams, seeps, monitor wells, and lysimeters on a monthly basis to evaluate changes in water quality resulting from the addition of alkaline waste or urban sewage sludge to the reclaimed mine-spoil surface. The mines are about 3.5 miles apart and were mined for bituminous coal of the upper and lower Clarion seams of the Allegheny Group of Pennsylvanian age. The coal had high sulfur (greater than 2 weight percent) concentrations. Acidic mine drainage is present at both mines. At one mine, about 8 years after mining was completed, large quantities (greater than 400 tons per acre) of alkaline waste consisting of limestone and lime-kiln flue dust were applied on two 2.5-acre plots within the 65-acre mine area. Water-quality data for the alkaline-addition plots and surrounding area were collected for 1 year before and 3 years after application of the alkaline additives (May 1983-July 1987). Data collected for the alkaline-addition study include ground-water level, surface-water discharge rate, temperature, specific conductance, pH, and concentrations of alkalinity, acidity, sulfate, iron (total and ferrous), manganese, aluminum, calcium, and magnesium. At the other mine, about 3.5 years after mining was completed, urban sewage sludge was applied over 60 acres within the 150-acre mine area. Waterquality data for the sludge-addition study were collected for 3.5 years after the application of the sludge (June 1986-December 1989). Data collected for the sludge-addition study include the above constituents plus dissolved oxygen, redox potential (Eh), and concentrations of dissolved solids, phosphorus, nitrogen species, sulfide, chloride, silica, sodium, potassium, cyanide, arsenic, barium

  5. Urban sewage lipids in the suspended particulate matter of a coral reef under river influence in the South West Gulf of Mexico.

    Science.gov (United States)

    Carreón-Palau, Laura; Parrish, Christopher C; Pérez-España, Horacio

    2017-10-15

    Nutritional quality of suspended particulate matter (SPM) and the degree of human fecal pollution in the largest coral reef system in the southwest Gulf of Mexico were evaluated using lipid classes, fatty acids (FA) and sterols in the dry and rainy seasons. High proportions of triacylglycerols and saturated and monounsaturated FA were detected in the SPM however it was considered poor quality because it had low proportions of highly unsaturated FA which can be used to determine production of marine biogenic material of dietary value to pelagic and benthic organisms. Urban sewage organic carbon was traced with coprostanol. The reference value of coprostanol from the point source of pollution was set using two samples from a sewage treatment plant processing waste from >140,000 people near the coral reef system, and it was contrasted with one river station and nine marine stations including six coral reefs. The concentration of coprostanol in the SPM was 3621 ± 98 ng L -1 comprising 26% of total sterols. During the dry season, the river was contaminated upstream with human feces as evidenced by coprostanol at 1823 ng L -1 , the 5β-coprostanol: cholesterol ratio at 0.5, and 5β-coprostanol: [5α-cholestanol+5β-coprostanol] at 0.7. In contrast, marine stations had concentrations of coprostanol lower than a suggested regulation limit for tropical marine coastal waters (30 ng L -1 ), ranging between 6 and 28 ng L -1 . During the rainy season a dilution effect was detected in the river, however significantly higher concentrations of coprostanol in the marine stations were detected ranging between 15 and 215 ng L -1 , higher than the tentative tropical regulation range (30-100 ng L -1 ). Among the reefs, the nearshore one, 14.3 km from the treatment plant, was more exposed to human-fecal pollution, and offshore reefs, >17.3 km from the plant, had a lower degree of contamination. Finally, only three stations were clearly uncontaminated during both seasons

  6. An assessment of landscape characteristics affecting estuarine nitrogen loading in an urban watershed.

    Science.gov (United States)

    Yang, Xiaojun

    2012-02-01

    Exploring the quantitative association between landscape characteristics and the ecological conditions of receiving waters has recently become an emerging area for eco-environmental research. While the landscape-water relationship research has largely targeted on inland aquatic systems, there has been an increasing need to develop methods and techniques that can better work with coastal and estuarine ecosystems. In this paper, we present a geospatial approach to examine the quantitative relationship between landscape characteristics and estuarine nitrogen loading in an urban watershed. The case study site is in the Pensacola estuarine drainage area, home of the city of Pensacola, Florida, USA, where vigorous urban sprawling has prompted growing concerns on the estuarine ecological health. Central to this research is a remote sensor image that has been used to extract land use/cover information and derive landscape metrics. Several significant landscape metrics are selected and spatially linked with the nitrogen loading data for the Pensacola bay area. Landscape metrics and nitrogen loading are summarized by equal overland flow-length rings, and their association is examined by using multivariate statistical analysis. And a stepwise model-building protocol is used for regression designs to help identify significant variables that can explain much of the variance in the nitrogen loading dataset. It is found that using landscape composition or spatial configuration alone can explain most of the nitrogen loading variability. Of all the regression models using metrics derived from a single land use/cover class as the independent variables, the one from the low density urban gives the highest adjusted R-square score, suggesting the impact of the watershed-wide urban sprawl upon this sensitive estuarine ecosystem. Measures towards the reduction of non-point source pollution from urban development are necessary in the area to protect the Pensacola bay ecosystem and its

  7. Urban summer heat load. Meteorological data as a proxy for metropolitan biodiversity

    Energy Technology Data Exchange (ETDEWEB)

    Kappes, Heike [Naturalis Biodiversity Center, Leiden (Netherlands); Katzschner, Lutz [Kassel Univ. (Germany). Environmental Meteorological Dept.; Nowak, Carsten [Senckenberg Gesellschaft fuer Naturforschung, Gelnhausen (Germany). Conservation Genetics Section; Biodiversity and Climate Research Centre (BiK-F), Frankfurt am Main (Germany)

    2012-10-15

    Regional climate models forecast that the incidence of extreme heat waves will increase in Central Europe, and the associated intensification of urban heat islands causes concerns about human health and biodiversity. We investigated species diversity of terrestrial gastropods across an urban gradient in a metropolitan area. We considered 34 sites of different degrees of urbanization and of different thermal stress classes (TSC) that were derived from a classification of urban heat load based on the physiological equivalent temperature (PET). A total of 31 species were recorded with 0-21 species per site (mean: 4.4 {+-} 5.2 species per site). Alpha diversity was best explained by TSC, bush cover and perennial vegetation cover, and it decreased with increasing thermal stress. Overall, thermal stress predicted snail and slug species richness better than urban cover (ANOVA(analysis of variance); TSC: F = 10.0, p < 0.001; urbanization: F = 3.9, p = 0.018), and the proportional loss in species richness was higher for native species than for introduced species. The results indicate that climatic stress contributes to the impoverishment of biodiversity in urban areas. We propose that TSC and/or PET are useful indicators for environmental stress levels in biodiversity studies in natural and anthropogenically transformed landscapes. (orig.)

  8. Performance of a pilot-scale constructed wetland for stormwater runoff and domestic sewage treatment on the banks of a polluted urban river.

    Science.gov (United States)

    Guo, Weijie; Li, Zhu; Cheng, Shuiping; Liang, Wei; He, Feng; Wu, Zhenbin

    2014-01-01

    To examine the performance of a constructed wetland system on stormwater runoff and domestic sewage (SRS) treatment in central east China, two parallel pilot-scale integrated constructed wetland (ICW) systems were operated for one year. Each ICW consisted of a down-flow bed, an up-flow bed and a horizontal subsurface flow bed. The average removal rates of chemical oxygen demand (CODCr), total suspended solids (TSS), ammonia (NH4(+)-N), total nitrogen (TN) and total phosphorus (TP) were 63.6, 91.9, 38.7, 43.0 and 70.0%, respectively, and the corresponding amounts of pollutant retention were approximately 368.3, 284.9, 23.2, 44.6 and 5.9 g m(-2) yr(-1), respectively. High hydraulic loading rate (HLR) of 200 mm/d and low water temperatures (<15 °C) resulted in significant decrease in removals for TP and NH4(+)-N, but had no significant effects on removals of COD and TSS. These results indicated that the operation of this ICW at higher HLR (200 mm/d) might be effective and feasible for TSS and COD removal, but for acceptable removal efficiencies of nitrogen and phosphorus it should be operated at lower HLR (100 mm/d). This kind of ICW could be employed as an effective technique for SRS treatment.

  9. Removal of antibiotics and antibiotic resistance genes from domestic sewage by constructed wetlands: Optimization of wetland substrates and hydraulic loading.

    Science.gov (United States)

    Chen, Jun; Wei, Xiao-Dong; Liu, You-Sheng; Ying, Guang-Guo; Liu, Shuang-Shuang; He, Liang-Ying; Su, Hao-Chang; Hu, Li-Xin; Chen, Fan-Rong; Yang, Yong-Qiang

    2016-09-15

    This study aimed to assess removal potential of antibiotics and antibiotic resistance genes (ARGs) in raw domestic wastewater by various mesocosm-scale horizontal subsurface-flow constructed wetlands (CWs) planted Cyperus alternifolius L. with different design parameters. Twelve CWs with three hydraulic loading rates (HLR 10, 20 and 30cm/day) and four substrates (oyster shell, zeolite, medical stone and ceramic) were set up in order to select the best optimized wetland. The result showed that 7 target antibiotics compounds including erythromycin-H2O, lincomycin, monensin, ofloxacin, sulfamerazine, sulfamethazine and novobiocin were detected, and all selected 18 genes (three sulfonamide resistance genes (sul1, sul2 and sul3), four tetracycline resistance genes (tetG, tetM, tetO and tetX), two macrolide resistance genes (ermB and ermC), three quinolone resistance genes (qnrB, qnrD and qnrS) and four chloramphenicol resistance genes (cmlA, fexA, fexB and floR)) and two integrase genes (int1 and int2) were positively detected in the domestic wastewaters. The aqueous removal rates of the total antibiotics ranged from17.9 to 98.5%, while those for the total ARGs varied between 50.0 and 85.8% by the mesocosm-scale CWs. After considering their aqueous removal rates in combination with their mass removals, the CW with zeolite as the substrate and HLR of 20cm/day was selected as the best choice. Combined chemical and biological analyses indicate that both microbial degradation and physical sorption processes were responsible for the fate of antibiotics and ARGs in the wetlands. The findings from this study suggest constructed wetlands could be a promising technology for the removal of emerging contaminants such as antibiotics and ARGs in domestic wastewater. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Integrated model of biopurification system for home sewage. A proposal for peri-urban communities from south center of Chile

    International Nuclear Information System (INIS)

    Parra Pierart, Izaul; Chiang Rojas, Gustavo

    2013-01-01

    The rapid growth of world population and its impacts has led to search new sources of water supply. Wastewater constitutes an additional source to satisfy the demand of this resource. Diverse researchers have designed alternatives for improve its processing and promote its utilization. This study examines some alternatives of bio-purification and proposes a conceptual design of a hybrid system that combines the use of a bio filter with artificial wetlands. The model designed contributes to improve water resources management and has educational, landscape and environmental benefits for peri-urban communities. Besides constitutes an alternative to promote more efficiently natural resources management at the local level.

  11. Perspective loads of transformer substations at development of urban power supply systems

    Directory of Open Access Journals (Sweden)

    Svetlana Guseva

    2012-06-01

    Full Text Available In work the system approach to formation of the urban power supply system is given. The hierarchical structure of the construction, voltage levels and load densities is considered. The mathematical and geometrical modeling of service areas for transformer substations of diff erent voltage is fulfi lled. Determination of perspective loads of transformer substations is given. The method of graphic placement of transformer substations in the city territory for new substations at existing structure of networks is off ered. The calculation program Microsoft EXCEL and the graphic program AutoCad are used for realization of method. The method allows fi nding a rational decision for the development of urban power supply system on the beginning design stages in conditions of the information uncertainty.

  12. [Pollution load and the first flush effect of phosphorus in urban runoff of Wenzhou City].

    Science.gov (United States)

    Zhou, Dong; Chen, Zhen-lou; Bi, Chun-juan

    2012-08-01

    Five typical rainfalls were monitored in two different research areas of Wenzhou municipality. The pH and concentrations of total phosphorus (TP), dissolved phosphorus (DP), particulate phosphorus (PP), total inorganic carbon (TIC), total organic carbon (TOC), total suspended substances (TSS), BOD5 and COD in six different kinds of urban runoff were measured. The results showed that, the concentrations of TP, DP and PP in different kinds of urban runoff of Wenzhou ranged from 0.01 to 4.32 mg x L(-1), ND to 0.88 mg x L(-1) and ND to 4.31 mg x L(-1), respectively. In the early stages of runoff process PP was dominated, while in the later, the proportion of DP in most of the runoff samples would show a rising trend, especially in roof and outlet runoff. Judged by the event mean concentration (EMC) of TP and DP in these five rainfalls, some kinds of urban runoff could cause environmental pressure to the next level receiving water bodies. Meanwhile, the differences among the TP and DP content (maximum, minimum and mean content) in various urban runoffs were significant, and so were the differences among various rainfall events. According to the M (V) curve, the first flush effect of TP in most kinds of urban runoff was common; while the first flush effect of DP was more difficult to occur comparing with TP. Not only the underlying surface types but also many physico-chemical properties of runoff could affect the concentration of TP in urban runoff. All the results also suggested that different best management plans (BMPs) should be selected for various urban runoff types for the treatment of phosphorus pollution, and reducing the concentration of TSS is considered as one of the effective ways to decrease the pollution load of phosphorus in urban runoff.

  13. Storm loads of culturable and molecular fecal indicators in an inland urban stream.

    Science.gov (United States)

    Liao, Hehuan; Krometis, Leigh-Anne H; Cully Hession, W; Benitez, Romina; Sawyer, Richard; Schaberg, Erin; von Wagoner, Emily; Badgley, Brian D

    2015-10-15

    Elevated concentrations of fecal indicator bacteria in receiving waters during wet-weather flows are a considerable public health concern that is likely to be exacerbated by future climate change and urbanization. Knowledge of factors driving the fate and transport of fecal indicator bacteria in stormwater is limited, and even less is known about molecular fecal indicators, which may eventually supplant traditional culturable indicators. In this study, concentrations and loading rates of both culturable and molecular fecal indicators were quantified throughout six storm events in an instrumented inland urban stream. While both concentrations and loading rates of each fecal indicator increased rapidly during the rising limb of the storm hydrographs, it is the loading rates rather than instantaneous concentrations that provide a better estimate of transport through the stream during the entire storm. Concentrations of general fecal indicators (both culturable and molecular) correlated most highly with each other during storm events but not with the human-associated HF183 Bacteroides marker. Event loads of general fecal indicators most strongly correlated with total runoff volume, maximum discharge, and maximum turbidity, while event loads of HF183 most strongly correlated with the time to peak flow in a hydrograph. These observations suggest that collection of multiple samples during a storm event is critical for accurate predictions of fecal indicator loading rates and total loads during wet-weather flows, which are required for effective watershed management. In addition, existing predictive models based on general fecal indicators may not be sufficient to predict source-specific genetic markers of fecal contamination. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Sewage Treatment

    Science.gov (United States)

    1991-01-01

    Stennis Space Center's aquaculture research program has led to an attractive wastewater treatment for private homes. The system consists of a septic tank or tanks for initial sewage processing and a natural secondary treatment facility for further processing of septic tanks' effluent, consisting of a narrow trench, which contains marsh plants and rocks, providing a place for microorganisms. Plants and microorganisms absorb and digest, thus cleansing partially processed wastewater. No odors are evident and cleaned effluent may be discharged into streams or drainage canals. The system is useful in rural areas, costs about $1,900, and requires less maintenance than mechanical systems.

  15. Antibiotic resistant bacteria in urban sewage: Role of full-scale wastewater treatment plants on environmental spreading.

    Science.gov (United States)

    Turolla, A; Cattaneo, M; Marazzi, F; Mezzanotte, V; Antonelli, M

    2018-01-01

    The presence of antibiotic resistant bacteria (ARB) in wastewater was investigated and the role of wastewater treatment plants (WWTPs) in promoting or limiting antibiotic resistance was assessed. Escherichia coli (E. coli) and total heterotrophic bacteria (THB) resistance to ampicillin, chloramphenicol and tetracycline was monitored in three WWTPs located in Milan urban area (Italy), differing among them for the operating parameters of biological process, for the disinfection processes (based on sodium hypochlorite, UV radiation, peracetic acid) and for the discharge limits to be met. Wastewater was collected from three sampling points along the treatment sequence (WWTP influent, effluent from sand filtration, WWTP effluent). Antibiotic resistance to ampicillin was observed both for E. coli and for THB. Ampicillin resistant bacteria in the WWTP influents were 20-47% of E. coli and 16-25% of THB counts. A limited resistance to chloramphenicol was observed only for E. coli, while neither for E. coli nor for THB tetracycline resistance was observed. The biological treatment and sand filtration led to a decrease in the maximum percentage of ampicillin-resistant bacteria (20-29% for E. coli, 11-21% for THB). However, the conventionally adopted parameters did not seem adequate to support an interpretation of WWTP role in ARB spread. Peracetic acid was effective in selectively acting on antibiotic resistant THB, unlike UV radiation and sodium hypochlorite. The low counts of E. coli in WWTP final effluents in case of agricultural reuse did not allow to compare the effect of the different disinfection processes on antibiotic resistance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Predicting runoff induced mass loads in urban watersheds: Linking land use and pyrethroid contamination.

    Science.gov (United States)

    Chinen, Kazue; Lau, Sim-Lin; Nonezyan, Michael; McElroy, Elizabeth; Wolfe, Becky; Suffet, Irwin H; Stenstrom, Michael K

    2016-10-01

    Pyrethroid pesticide mass loadings in the Ballona Creek Watershed were calculated using the volume-concentration method with a Geographic Information Systems (GIS) to explore potential relationships between urban land use, impervious surfaces, and pyrethroid runoff flowing into an urban stream. A calibration of the GIS volume-concentration model was performed using 2013 and 2014 wet-weather sampling data. Permethrin and lambda-cyhalothrin were detected as the highest concentrations; deltamethrin, lambda-cyhalothrin, permethrin and cyfluthrin were the most frequently detected synthetic pyrethroids. Eight neighborhoods within the watershed were highlighted as target areas based on a Weighted Overlay Analysis (WOA) in GIS. Water phase concentration of synthetic pyrethroids (SPs) were calculated from the reported usage. The need for stricter BMP and consumer product controls was identified as a possible way of reducing the detections of pyrethroids in Ballona Creek. This model has significant implications for determining mass loadings due to land use influence, and offers a flexible method to extrapolate data for a limited amount of samplings for a larger watershed, particularly for chemicals that are not subject to environmental monitoring. Offered as a simple approach to watershed management, the GIS-volume concentration model has the potential to be applied to other target pesticides and is useful for simulating different watershed scenarios. Further research is needed to compare results against other similar urban watersheds situated in mediterranean climates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Modelling reduction of urban heat load in Vienna by modifying surface properties of roofs

    Science.gov (United States)

    Žuvela-Aloise, Maja; Andre, Konrad; Schwaiger, Hannes; Bird, David Neil; Gallaun, Heinz

    2018-02-01

    The study examines the potential of urban roofs to reduce the urban heat island (UHI) effect by changing their reflectivity and implementing vegetation (green roofs) using the example of the City of Vienna. The urban modelling simulations are performed based on high-resolution orography and land use data, climatological observations, surface albedo values from satellite imagery and registry of the green roof potential in Vienna. The modelling results show that a moderate increase in reflectivity of roofs (up to 0.45) reduces the mean summer temperatures in the densely built-up environment by approximately 0.25 °C. Applying high reflectivity materials (roof albedo up to 0.7) leads to average cooling in densely built-up area of approximately 0.5 °C. The green roofs yield a heat load reduction in similar order of magnitude as the high reflectivity materials. However, only 45 % of roof area in Vienna is suitable for greening and the green roof potential mostly applies to industrial areas in city outskirts and is therefore not sufficient for substantial reduction of the UHI effect, particularly in the city centre which has the highest heat load. The strongest cooling effect can be achieved by combining the green roofs with high reflectivity materials. In this case, using 50 or 100 % of the green roof potential and applying high reflectivity materials on the remaining surfaces have a similar cooling effect.

  18. Benzo[a]pyrene in urban environments of eastern Moscow: pollution levels and critical loads

    Science.gov (United States)

    Kasimov, Nikolay S.; Kosheleva, Natalia E.; Nikiforova, Elena M.; Vlasov, Dmitry V.

    2017-02-01

    Polycyclic aromatic hydrocarbons (PAHs), particularly benzo[a]pyrene (BaP), are toxic compounds emitted from various anthropogenic sources. Understanding the BaP concentrations, dynamics and decomposition in soil is required to assess the critical loads of BaP in urban environments. This study is the first attempt to evaluate all major input and output components of benzo[a]pyrene (BaP) balance and to calculate the permissible load on the urban environment in different land-use zones in the Eastern district of Moscow. BaP contamination of the snow cover in the Eastern district of Moscow was related to daily BaP fallout from the atmosphere. In 2010, the mean content of the pollutant in the snow dust was 1942 ng g-1, whereas the average intensity of its fallout was 7.13 ng m-2 per day. Across the territory, BaP winter fallout intensities varied from 0.3 to 1100 ng m-2 per day. The average BaP content in the surface (0-10 cm) soil horizons was 409 ng g-1, which is 83 times higher than the local background value and 20 times higher than the maximum permissible concentration (MPC) accepted in Russia. The variations in soil and snow BaP concentrations among different land-use zones were examined. A significant contribution of BaP from the atmosphere to urban soils was identified. Based on the measurements of BaP atmospheric fallout and BaP reserves in the soils, the critical loads of BaP for the land-use zones in the Eastern district were calculated for different values of degradation intensity and different exposure times. It was established that at an annual degradation intensity of 1-10 %, ecologically safe BaP levels in the soils of all land-use zones, excluding the agricultural zone, will only be reached after many decades or centuries.

  19. Pre- and post-fire pollutant loads in an urban fringe watershed in Southern California.

    Science.gov (United States)

    Burke, M P; Hogue, T S; Kinoshita, A M; Barco, J; Wessel, C; Stein, E D

    2013-12-01

    Post-fire runoff has the potential to be a large source of contaminants to downstream areas. However, the magnitude of this effect in urban fringe watersheds adjacent to large sources of airborne contaminants is not well documented. The current study investigates the impacts of wildfire on stormwater contaminant loading from the upper Arroyo Seco watershed, burned in 2009. This watershed is adjacent to the Greater Los Angeles, CA, USA area and has not burned in over 60 years. Consequently, it acts as a sink for regional urban pollutants and presents an opportunity to study the impacts of wildfire. Pre- and post-fire storm samples were collected and analyzed for basic cations, trace metals, and total suspended solids. The loss of vegetation and changes in soil properties from the fire greatly increased the magnitude of storm runoff, resulting in sediment-laden floods carrying high concentrations of particulate-bound constituents. Post-fire concentrations and loads were up to three orders of magnitude greater than pre-fire values for many trace metals, including lead and cadmium. A shift was also observed in the timing of chemical delivery, where maximum suspended sediment, trace metal, and cation concentrations coincided with, rather than preceded, peak discharge in the post-fire runoff, amplifying the fire's impacts on mass loading. The results emphasize the importance of sediment delivery as a primary mechanism for post-fire contaminant transport and suggest that traditional management practices that focus on treating only the early portion of storm runoff may be less effective following wildfire. We also advocate that watersheds impacted by regional urban pollutants have the potential to pose significant risk for downstream communities and ecosystems after fire.

  20. Sewage Monitors

    Science.gov (United States)

    1987-01-01

    Every U.S. municipality must determine how much waste water it is processing and more importantly, how much is going unprocessed into lakes and streams either because of leaks in the sewer system or because the city's sewage facilities were getting more sewer flow than they were designed to handle. ADS Environmental Services, Inc.'s development of the Quadrascan Flow Monitoring System met the need for an accurate method of data collection. The system consists of a series of monitoring sensors and microcomputers that continually measure water depth at particular sewer locations and report their findings to a central computer. This provides precise information to city managers on overall flow, flow in any section of the city, location and severity of leaks and warnings of potential overload. The core technology has been expanded upon in terms of both technical improvements, and functionality for new applications, including event alarming and control for critical collection system management problems.

  1. Design of a new urban wind turbine airfoil using a pressure-load inverse method

    Energy Technology Data Exchange (ETDEWEB)

    Henriques, J.C.C.; Gato, L.M.C. [IDMEC, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Marques da Silva, F. [LNEC - Laboratorio Nacional de Engenharia Civil, Av. Brasil, 101, 1700-066 Lisboa (Portugal); Estanqueiro, A.I. [INETI - Instituto Nacional de Engenharia, Tecnologia e Inovacao Estrada do Paco do Lumiar, 1649-038 Lisboa (Portugal)

    2009-12-15

    This paper presents the design methodology of a new wind turbine airfoil that achieves high performance in urban environment by increasing the maximum lift. For this purpose, an inverse method was applied to obtain a new wind turbine blade section with constant pressure-load along the chord, at the design inlet angle. In comparison with conventional blade section designs, the new airfoil has increased maximum lift, reduced leading edge suction peak and controlled soft-stall behaviour, due to a reduction of the adverse pressure gradient on the suction side. Wind tunnel experimental results confirmed the computational results. (author)

  2. Sewage sludge application on cultivated soils: effects on runoff and trace metal load Aplicação de lodo de esgoto em solos agrícolas: efeitos na enxurrada e no carreamento de metais

    Directory of Open Access Journals (Sweden)

    Marcelo Valadares Galdos

    2009-06-01

    Full Text Available The use of sewage sludge in agricultural soils as a macro and micronutrient source and as a soil conditioner has been one of the alternatives for its disposal. However, sewage sludge contains trace metals, which are potential sources of pollution. The goal of this study was to evaluate the effect of sewage sludge application on surface water contamination through runoff when it was applied in a soil cultivated with corn. The effect of sludge application on the concentration and load of copper, nickel and zinc and the volume of runoff water and sediment were evaluated. The experiment was set up in plots used to study erosion losses in Campinas, Sao Paulo State, Brazil. The soil is a clayey Rhodic Hapludox. Three treatments were studied: no sewage sludge, sewage sludge to supply the N required by the crop and twice that amount, with four replications. The water and sediment lost by runoff were measured after each rainfall, and sampled for chemical analysis. The volumes of water and sediment lost by runoff decreased after sewage sludge application. The waste application increased trace metal concentration in the runoff water and sediment, especially zinc, which was present in high concentration in the sewage sludge used. Nevertheless, the load of trace metals transported from the plot was mostly dependent on the total runoff volume. Most of the Cu, Zn and Ni losses were via sediment, and occurred in a few highly erosive rainfall events in the period studied.O uso de lodo de esgoto em solos agrícolas como fonte de macro e micronutrientes e como condicionador de solos tem sido uma das alternativas para sua disposição final. O lodo de esgoto, entretanto, contém metais que são potencialmente fonte de poluição. Estudou-se o efeito da aplicação de lodo de esgoto na contaminação de águas superficiais por meio da enxurrada proveniente de solo agrícola cultivado com milho. O efeito da aplicação do lodo na concentração e no carreamento de

  3. Canadian House Dust Study: Population-based concentrations, loads and loading rates of arsenic, cadmium, chromium, copper, nickel, lead, and zinc inside urban homes

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Pat E. [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Levesque, Christine [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Chénier, Marc; Gardner, H. David [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Jones-Otazo, Heather [Regions and Programs Branch, Health Canada, 180 Queen Street West, Toronto, ON, Canada M5V 3L7 (Canada); Petrovic, Sanya [Contaminated Sites Division, Healthy Environments and Consumer Safety Branch, Health Canada, 269 Laurier Ave West, Ottawa, ON, Canada K1A 0K9 (Canada)

    2013-01-15

    The Canadian House Dust Study was designed to obtain nationally representative urban house dust metal concentrations (μg g{sup −1}) and metal loadings (μg m{sup −2}) for arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), lead (Pb), and zinc (Zn). Consistent sampling of active dust of known age and provenance (area sampled) also permitted the calculation of indoor loading rates (mg m{sup −2} day{sup −1} for dust and μg m{sup −2} day{sup −1} for metals) for the winter season (from 2007 to 2010) when houses are most tightly sealed. Geomean/median indoor dust loading rates in homes located more than 2 km away from industry of any kind (9.6/9.1 mg m{sup −2} day{sup −1}; n = 580) were significantly lower (p < .001) than geomean (median) dust loading rates in homes located within 2 km of industry (13.5/13.4 mg m{sup −2} day{sup −1}; n = 421). Proximity to industry was characterized by higher indoor metal loading rates (p < .003), but no difference in dust metal concentrations (.29 ≥ p ≤ .97). Comparisons of non-smokers' and smokers' homes in non-industrial zones showed higher metal loading rates (.005 ≥ p ≤ .038) in smokers' homes, but no difference in dust metal concentrations (.15 ≥ p ≤ .97). Relationships between house age and dust metal concentrations were significant for Pb, Cd and Zn (p < .001) but not for the other four metals (.14 ≥ p ≤ .87). All seven metals, however, displayed a significant increase in metal loading rates with house age (p < .001) due to the influence of higher dust loading rates in older homes (p < .001). Relationships between three measures of metals in house dust – concentration, load, and loading rate – in the context of house age, smoking behavior and urban setting consistently show that concentration data is a useful indicator of the presence of metal sources in the home, whereas dust mass is the overriding influence on metal loadings and loading rates

  4. Hydrology, water quality, and response to changes in phosphorus loading of Minocqua and Kawaguesaga Lakes, Oneida County, Wisconsin, with special emphasis on effects of urbanization

    Science.gov (United States)

    Garn, Herbert S.; Robertson, Dale M.; Rose, William J.; Saad, David A.

    2010-01-01

    Minocqua and Kawaguesaga Lakes are 1,318- and 690-acre interconnected lakes in the popular recreation area of north-central Wisconsin. The lakes are the lower end of a complex chain of lakes in Oneida and Vilas Counties, Wis. There is concern that increased stormwater runoff from rapidly growing residential/commercial developments and impervious surfaces from the urbanized areas of the Town of Minocqua and Woodruff, as well as increased effluent from septic systems around their heavily developed shoreline has increased nutrient loading to the lakes. Maintaining the quality of the lakes to sustain the tourist-based economy of the towns and the area was a concern raised by the Minocqua/Kawaguesaga Lakes Protection Association. Following several small studies, a detailed study during 2006 and 2007 was done by the U.S. Geological Survey, in cooperation with the Minocqua/Kawaguesaga Lakes Protection Association through the Town of Minocqua to describe the hydrology and water quality of the lakes, quantify the sources of phosphorus including those associated with urban development and to better understand the present and future effects of phosphorus loading on the water quality of the lakes. The water quality of Minocqua and Kawaguesaga Lakes appears to have improved since 1963, when a new sewage-treatment plant was constructed and its discharge was bypassed around the lakes, resulting in a decrease in phosphorus loading to the lakes. Since the mid-1980s, the water quality of the lakes has changed little in response to fluctuations in phosphorus loading from the watershed. From 1986 to 2009, summer average concentrations of near-surface total phosphorus in the main East Basin of Minocqua Lake fluctuated from 0.009 mg/L to 0.027 mg/L but generally remained less than 0.022 mg/L, indicating that the lake is mesotrophic. Phosphorus concentrations from 1988 through 1996, however, were lower than the long-term average, possibly the result of an extended drought in the area

  5. Comparative metagenome of a stream impacted by the urbanization phenomenon

    Directory of Open Access Journals (Sweden)

    Julliane Dutra Medeiros

    Full Text Available Abstract Rivers and streams are important reservoirs of freshwater for human consumption. These ecosystems are threatened by increasing urbanization, because raw sewage discharged into them alters their nutrient content and may affect the composition of their microbial community. In the present study, we investigate the taxonomic and functional profile of the microbial community in an urban lotic environment. Samples of running water were collected at two points in the São Pedro stream: an upstream preserved and non-urbanized area, and a polluted urbanized area with discharged sewage. The metagenomic DNA was sequenced by pyrosequencing. Differences were observed in the community composition at the two sites. The non-urbanized area was overrepresented by genera of ubiquitous microbes that act in the maintenance of environments. In contrast, the urbanized metagenome was rich in genera pathogenic to humans. The functional profile indicated that the microbes act on the metabolism of methane, nitrogen and sulfur, especially in the urbanized area. It was also found that virulence/defense (antibiotic resistance and metal resistance and stress response-related genes were disseminated in the urbanized environment. The structure of the microbial community was altered by uncontrolled anthropic interference, highlighting the selective pressure imposed by high loads of urban sewage discharged into freshwater environments.

  6. Calculation Method for Load Capacity of Urban Rail Transit Station considering Cascading Failure

    Directory of Open Access Journals (Sweden)

    Jiajun Huang

    2018-01-01

    Full Text Available The load capacity of urban rail transit station is of great significance to provide reference in station design and operation management. However, it is difficult to carry out quantitative calculation quickly and accurately due to the complex interaction among passenger behaviors, facility layout, and the limit capacity of single facility. In this paper, the association network of facilities is set up based on the analysis of passenger service chain in station. Then the concept of cascading failure is introduced to the dynamic calculation model of load capacity, which is established on the user-equilibrium allocation model. The solution algorithm is optimized with node attack strategy of complex network to effectively reduce the computational complexity. Finally, a case study of Lujiabang Road Station in Shanghai is carried out and compared with the simulation results of StaPass, verifying the feasibility of this approach. The proposed method can not only search for the bottleneck of capacity, but also help to trace the loading variation of facilities network in different scenarios, providing theoretical supports on passenger flow organization.

  7. Runoff and loads of nutrients and heavy metals from an urbanized area.

    Science.gov (United States)

    Shirasuna, H; Fukushima, T; Matsushige, K; Imai, A; Ozaki, N

    2006-01-01

    To investigate the run-off characteristics of dissolved and particulate substances from a heavily urbanized area (basin area: 95 ha, percentage of impervious surfaces: 60%), sensors for measuring water level, water temperature, DO, pH, electric conductivity (EC), turbidity and ammonium ion were placed in the channel connecting storm sewers and natural river, together with water sampling for analyzing SS, nutrients and metals. While both turbidity and EC showed apparent "first flush", the peaks of EC were always earlier than those of turbidity. In a similar manner, dissolved nutrients and metals exhibited earlier "first flush" compared with particulate nutrients and acid-extractable metals. Significantly positive correlations between EC and dissolved substances as well as those between turbidity and particulate (acid-extractable minus dissolved) substances were usually observed, and two distinct different regressions were found between the two datasets separated before and after the concentration peaks. Using these relationships, the total loads during the respective rainfall events were calculated on the basis of EC and turbidity changes. The total loads of nitrogen, zinc, etc. were nearly proportional to the lengths of non-rainfall periods before the events, indicating that these loads derived from the atmospheric deposition.

  8. Research on the sewage treatment in high altitude region based on Lhasa Sewage Treatment Plant

    Science.gov (United States)

    Xu, Jin; Li, Shuwen

    2017-12-01

    Sewage treatment is of great significance to enhance environmental quality, consolidate pollution prevention and ecological protection, and ensure sustainable economic and social development in high altitude region. However, there are numerous difficulties in sewage treatment due to the alpine climate, the relatively low economic development level, and the backward operation and management styles, etc. In this study, the characteristics of influent quality in the sewage treatment plant in Lhasa are investigated by analysing the influent BOD5/COD and BOD5/TN, comparing key indexes recorded from 2014 to 2016 with the hinterland. Results show that the concentration of influent COD, BOD5, NH3-N and SS in the Lhasa sewage treatment plant, in which the sewage belongs to low-concentration urban sewage, is smaller than that in the domestic sewage treatment plants in the mainland. The concentration ratio of BOD5/COD and BOD5/TN is below 0.4 and 4, which indicates that the biodegradation is poor and the carbon sources are in bad demand. The consequences obtained play a vital role in the design, operation and management of sewage treatment plants in high altitude region.

  9. Vermicompostagem de lodo de esgoto urbano e bagaço de cana-de-açúcar Vermicomposting of urban sewage sludge and sugarcane bagasse

    Directory of Open Access Journals (Sweden)

    Carlos D. da Silva

    2002-12-01

    Full Text Available Com o objetivo de se avaliar alterações químicas no substrato orgânico no decorrer do processo de vermicompostagem de diferentes combinações de lodo de esgoto urbano (LEU com bagaço de cana-de-açúcar (BC, além de sua qualidade final como adubo orgânico, realizou-se um experimento em laboratório e campo. Os vermicompostos foram obtidos a partir dos tratamentos T1 = 150 kg de LEU; T2 = 121,6 kg de LEU + 97,30 kg de BC; T3 = 59 kg de LEU + 97,30 kg de BC; T4 = 35,5 kg de LEU + 97,30 kg de BC e T5 = 23,10 kg de LEU + 97,30 kg de BC. Para a realização do processo de vermicompostagem, foram utilizadas minhocas vermelhas-da-Califórnia (Eisenia fetida. As características químicas determinadas nos vermicompostos produzidos indicaram que os mesmos podem ser utilizados como adubo orgânico, principalmente no que se refere ao conteúdo de matéria orgânica, pH, relação C/N, concentração de nitrogênio e fósforo. As concentrações de metais pesados situaram-se abaixo dos limites de toxicidade, considerados pela legislação internacional. Aumento da proporção de LEU como substrato proporcionou aumento na concentração final de N, Ca e Mg, diminuídas de K.The purpose of the present study was to evaluate the chemical alterations in the substrate with time of the vermicomposting involving different combinations of urban sewage sludge (USS and sugarcane bagasse (SB, besides it's quality as organic fertilizer. The vermicomposts were obtained from the treatments T1= 150 kg of USS; T2 = 121.6 kg of USS + 97.30 kg of SB; T3 = 59 kg of USS + 97.30 kg of SB; T4 = 35.5 kg of USS + 97.30 kg of SB; T5= 23.10 kg of USS + 97.30 kg of SB. For the vermicomposting process, Red-California earthworm (Eisenia fetida was utilized. Chemical characteristics determined in the vermicomposts indicate that it can be used as organic fertilizer, mainly with regard to organic matter content, pH, C/N ratio, nitrogen and phosphorus levels. Heavy metal

  10. Sewage discharges and nutrient levels in Marimba River, Zimbabwe ...

    African Journals Online (AJOL)

    Sewage discharges and nutrient levels in Marimba River, Zimbabwe. ... Population distribution, land-use, industrial activity, urban agricultural ... River, one of the major inflow rivers into the Lake Chivero, Harare city\\'s main water supply source.

  11. The impact of major earthquakes and subsequent sewage discharges on the microbial quality of water and sediments in an urban river.

    Science.gov (United States)

    Devane, Megan L; Moriarty, Elaine M; Wood, David; Webster-Brown, Jenny; Gilpin, Brent J

    2014-07-01

    A series of large earthquakes struck the city of Christchurch, New Zealand in 2010-2011. Major damage sustained by the sewerage infrastructure required direct discharge of up to 38,000 m(3)/day of raw sewage into the Avon River of Christchurch for approximately six months. This allowed evaluation of the relationship between concentrations of indicator microorganisms (Escherichia coli, Clostridium perfringens and F-RNA phage) and pathogens (Campylobacter, Giardia and Cryptosporidium) in recreational water and sediment both during and post-cessation of sewage discharges. Giardia was the pathogen found most frequently in river water and sediment, although Campylobacter was found at higher levels in water samples. E. coli levels in water above 550 CFU/100 mL were associated with increased likelihood of detection of Campylobacter, Giardia and Cryptosporidium, supporting the use of E. coli as a reliable indicator for public health risk. The strength of the correlation of microbial indicators with pathogen detection in water decreased in the following order: E. coli>F-RNA phage>C. perfringens. All the microorganisms assayed in this study could be recovered from sediments. C. perfringens was observed to accumulate in sediments, which may have confounded its usefulness as an indicator of fresh sewage discharge. F-RNA phage, however, did not appear to accumulate in sediment and in conjunction with E. coli, may have potential as an indicator of recent human sewage discharge in freshwater. There is evidence to support the low-level persistence of Cryptosporidium and Giardia, but not Campylobacter, in river sediments after cessation of sewage discharges. In the event of disturbances of the sediment, it is highly probable that there could be re-mobilisation of microorganisms beyond the sediment-water exchange processes occurring under base flow conditions. Re-suspension events do, therefore, increase the potential risk to human health for those who participate in recreational

  12. Extremely fast increase in the organic loading rate during the co-digestion of rapeseed oil and sewage sludge in a CSTR--characterization of granules formed due to CaO addition to maintain process stability.

    Science.gov (United States)

    Kasina, M; Kleyböcker, A; Michalik, M; Würdemann, H

    2015-01-01

    In a co-digestion system running with rapeseed oil and sewage sludge, an extremely fast increase in the organic loading rate was studied to develop a procedure to allow for flexible and demand-driven energy production. The over-acidification of the digestate was successfully prevented by calcium oxide dosage, which resulted in granule formation. Mineralogical analyses revealed that the granules were composed of insoluble salts of long chain fatty acids and calcium and had a porous structure. Long chain fatty acids and calcium formed the outer cover of granules and offered interfaces on the inside thereby enhancing the growth of biofilms. With granule size and age, the pore size increased and indicated degradation of granular interfaces. A stable biogas production up to the organic loading rate of 10.4 kg volatile solids m(-3) d(-1) was achieved although the hydrogen concentration was not favorable for propionic acid degradation. However, at higher organic loading rates, unbalanced granule formation and degradation were observed. Obviously, the adaption time for biofilm growth was too short to maintain the balance, thereby resulting in a low methane yield.

  13. Inactivation of enteroviruses in sewage with ozone

    Energy Technology Data Exchange (ETDEWEB)

    Ivanova, O.E.; Bogdanov, M.V.; Kazantseva, V.A.; Gabrilevskaia, L.N.; Kodkind, G.K.H.

    The study of ozone inactivation of enteroviruses in sewage showed the presence in sewage of suspensions of organic origin and bacterial flora to influence the rate of inactivation. The inactivation rate of poliomyelitis virus in sewage free from organic suspension and bacterial flora was significantly higher than that in sewage containing such suspension and bacterial flora. The inactivation rate of enteroviruses was found not to depend upon the protein and salt composition and pH of sewage or strain appurtenance of viruses. The inactivation rate of enteroviruses directly depended upon the dose of ozone and time of contact with it. Differences in the resistance of different types of poliomyelitis virus, ECHO and Coxsackie viruses to the effect of ozone are likely exist. These differences are manifested within the range of relatively small doses of ozone. E. coli is more resistant to ozone than entero-viruses. The results of laboratory studies were used to choose the regimen of sanitation of urban sewage to be used in technological cycles of industrial enterprises.

  14. Towards a rational use of loading and unloading areas in urban environments

    Science.gov (United States)

    Barba, Daniel; Garcia-Villanueva, Sergio; Del-Campo-Pardo, Hector; March, Juan A.; Llanos, Diego R.

    2017-10-01

    Despite the efforts of the authorities, that promote the use of alternative transportation systems, the traffic still increases in European cities, leading not only to traffic jams but also to pollution episodes. Delivery vehicles are part of both problems, because of their intensive use, the advent of e-commerce, the limited number and sizes of loading and unloading areas in many ancient European cities, and the difficulties associated to keep track of the correct use of these spaces. In this work we propose an holistic solution to the management of delivery vehicles in urban environments. Our solution, called RYDER, is based on the use of BLE (Bluetooth Low Energy) devices that should be provided by the local authority to delivery vehicles, as part of their authorization to use the loading and unloading areas. With the help of low-cost, low-power antennas with Bluetooth and 4G capabilities installed next to each loading/unloading area, the authorities are able to know in real time (a) the use of these areas by delivery vehicles, (b) the paths of the vehicles while they travel across the city, (c) the time spent in each area by each one of them, and (d) with the help of a mobile/tablet App, the local Police can check in seconds the permissions of each vehicle using these public spaces. Moreover, the use of a GIS-based platform allows the Traffic Department to track online each particular vehicle, based on the loading/unloading spaces being used, and to infer the most representative paths they follow, an information that may guide the decision about where these spaces are really necessary and whether each particular vehicle follows their associated usage rules. The deployment of RYDER low-cost antennas can also serve for other purposes, such as to track the routes followed by public loan bicycles, or by other fleets of public vehicles. With the help of low-cost sensors, antennas can also return an estimation of pollution values, such as levels of ozone, particulate

  15. Retrofitting impervious urban infrastructure with green technology for rainfall-runoff restoration, indirect reuse and pollution load reduction

    International Nuclear Information System (INIS)

    Sansalone, John; Raje, Saurabh; Kertesz, Ruben; Maccarone, Kerrilynn; Seltzer, Karl; Siminari, Michele; Simms, Peter; Wood, Brandon

    2013-01-01

    The built environs alter hydrology and water resource chemistry. Florida is subject to nutrient criteria and is promulgating “no-net-load-increase” criteria for runoff and constituents (nutrients and particulate matter, PM). With such criteria, green infrastructure, hydrologic restoration, indirect reuse and source control are potential design solutions. The study simulates runoff and constituent load control through urban source area re-design to provide long-term “no-net-load-increases”. A long-term continuous simulation of pre- and post-development response for an existing surface parking facility is quantified. Retrofits include a biofiltration area reactor (BAR) for hydrologic and denitrification control. A linear infiltration reactor (LIR) of cementitious permeable pavement (CPP) provides infiltration, adsorption and filtration. Pavement cleaning provided source control. Simulation of climate and source area data indicates re-design achieves “no-net-load-increases” at lower costs compared to standard construction. The retrofit system yields lower cost per nutrient load treated compared to Best Management Practices (BMPs). -- Continuous simulation of climate and site data demonstrate that urban re-design using green infrastructure can provide long-term “no-net-load-increases” at a lower costs compared to BMPs

  16. The use of simulated rainfall to study the discharge process and the influence factors of urban surface runoff pollution loads.

    Science.gov (United States)

    Qinqin, Li; Qiao, Chen; Jiancai, Deng; Weiping, Hu

    2015-01-01

    An understanding of the characteristics of pollutants on impervious surfaces is essential to estimate pollution loads and to design methods to minimize the impacts of pollutants on the environment. In this study, simulated rainfall equipment was constructed to investigate the pollutant discharge process and the influence factors of urban surface runoff (USR). The results indicated that concentrations of total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and chemical oxygen demand (COD) appeared to be higher in the early period and then decreased gradually with rainfall duration until finally stabilized. The capacity and particle size of surface dust, rainfall intensity and urban surface slopes affected runoff pollution loads to a variable extent. The loads of TP, TN and COD showed a positive relationship with the surface dust capacity, whereas the maximum TSS load appeared when the surface dust was 0.0317 g·cm⁻². Smaller particle sizes (pollution carrying capacity of runoff, leading to higher pollution loads. Knowledge of the influence factors could assist in the management of USR pollution loads.

  17. Statistical summary of selected physical, chemical, and microbial characteristics, and estimates of constituent loads in urban stormwater, Maricopa County, Arizona

    Science.gov (United States)

    Lopes, T.J.; Fossum, K.D.; Phillips, J.V.; Monical, J.E.

    1995-01-01

    Stormwater and streamflow in the Phoenix, Arizona, area were monitored to determine the physical, chemical, and microbial characteristics of storm- water from areas having different land uses; to describe the characteristics of streamflow in a river that receives urban stormwater; and to estimate constituent loads in stormwater from unmonitored areas in Maricopa County, Arizona. Land use affects urban stormwater chemistry mostly because the percentage of impervious area controls the suspended-solids concentrations and varies with the type of land use. Urban activities also seem to concentrate cadmium, lead, and zinc in sediments. Urban stormwater had larger concentrations of chemical oxygen demand and biological oxygen demand, oil and grease, and higher counts of fecal bacteria than streamflow and could degrade the quality of the Salt River. Most regression equations for estimating constituent loads require three explanatory variables (total rainfall, drainage area, and per- centage of impervious area) and had standard errors that were from 65 to 266 percent. Localized areas that appear to contribute a large proportion of the constituent loads typically have 40 percent or more impervious area and are associated with industrial, commercial, and high-density residential land uses. The use of the mean value of the event-mean constituent concentrations measured in stormwater may be the best way of estimating constituent concentrations.

  18. Enhancement of urban heat load through social inequalities on an example of a fictional city King's Landing

    Science.gov (United States)

    Žuvela-Aloise, M.

    2017-03-01

    The numerical model MUKLIMO_3 is used to simulate the urban climate of an imaginary city as an illustrative example to demonstrate that the residential areas with deprived socio-economic conditions can exhibit an enhanced heat load at night, and thus more disadvantageous environmental conditions, compared with the areas of higher socio-economic status. The urban climate modelling simulations differentiate between orographic, natural landscape, building and social effects, where social differences are introduced by selection of location, building type and amount of vegetation. The model results show that the increase of heat load can be found in the areas inhabited by the poor population as a combined effect of natural and anthropogenic factors. The unfavourable location in the city and the building type, consisting of high density, low housing with high fraction of pavement and small amount of vegetation contribute to the formation of excessive heat load. This abstract example shows that the enhancement of urban heat load can be linked to the concept of a socially stratified city and is independent of the historical development of any specific city.

  19. Composting sewage sludge

    International Nuclear Information System (INIS)

    Epstein, E.

    1979-01-01

    Sewage sludge is predominantly organic matter containing domestic and industrial wastes. The inefficiency of the waste water treatment to destroy pathogens and stabilization of odor-producing volatile organic compounds necessitates further treatment before sludge can be used as a soil amendment or fertilizer. Composting, which is the rapid biological decomposition of the sludge organic matter is an excellent method of sludge stabilization. During the process, volatile organics are decomposed and many of the pathogens destoyed. The low cost of the process and its flexibility with respect to labor and capital makes the system highly attractive to municipalities. A major problem facing large urban waste water treatment facilities is the distribution or marketing. The light weight of the material, expensive hauling costs, and low fertilizer value reduce its attractiveness to the agricultural sector. Thus, the greatest market is for horticultural purposes, sod, nurseries, greenhouses, parks, and reclamation areas. The major potential benefits of irradiating compost as a means of further disinfection are: (1) elimination of any health hazard; (2) increase of market potential, i.e., providing more market outlets to distribute the material; (3) compliance with state and federal health regulations; and (4) enhancement of the economics of composting as a result of utilizing compost in speciality products commanding a higher value

  20. Sanitary and bacteriological aspects of sewage treatment.

    Science.gov (United States)

    Filipkowska, Zofia

    2003-01-01

    A study into the removal of contamination load and indicator bacteria was carried out in 1992-1996 in the mechanical, biological and chemical waste-water treatment plant WTP in Lezany, in the County of Reszel, in the Province of Warmia and Mazury in Poland. The results of chemical analyses found a high efficiency of removal of carbon compounds, COD (90%) and BOD (98%), in the process of purification of household sewage. In addition, a high effectiveness of total nitrogen, on average 71%, and unsatisfactory removal of ammonia nitrogen and phosphorus compounds were found. The results of microbiological analyses confirmed the high efficiency of removal of indicator bacteria in the process of sewage treatment from 94 to 97%. In the sewage after the final phase of purification in stabilization ponds, the following pathogenic bacteria were identified with the use of the EPL 21tests: Escherichia coli, Enterobacter agglomerans, Enterobacter aerogenes, Enterobacter cloacae, Enterobacter georgoriae, Citrobacter freundii, Klebsiella pnemoniae, Klebsiella oxytoca, Klebsiella ozaenae, Ervinia herbicola, Edwardsiella tarda, Serratia odoriefra, Serratia marcescens, Providencia alcalifaciens, Hafnia alvei, Yersina pestis, Yersina pseudotuberculosis, Yersinia fredericksenii, Salmonella spp., Shigella dysenteriae, Aeromons hydrophila, Pseudomonas aerulginosa. The obtained results show that although the sewage purification system is efficient and reduces the contamination load to the level required by the regulations (Ministry of Environmental Protection, Natural Resources and Forestry from 20 September 1991) and removes a great percentage of indicator bacteria, the purified sewage may be a source of pathogenic bacteria in inland waters.

  1. Assessing earthworm and sewage sludge impacts on microbiological and biochemical soil quality using multivariate analysis

    Directory of Open Access Journals (Sweden)

    Hanye Jafari Vafa

    2017-06-01

    Full Text Available Introduction: Land application of organic wastes and biosolids such as municipal sewage sludge has been an important and attractive practice for improving different properties of agricultural soils with low organic matter content in semi-arid regions, due to an increase of soil organic matter level and fertility. However, application of this organic waste may directly or indirectly affect soil bio-indicators such as microbial and enzymatic activities through a change in the activity of other soil organisms such as earthworms. Earthworms are the most important soil saprophagous fauna and much of the faunal biomass is attributed to the presence of these organisms in the soil. Therefore, it is crucial to evaluate the effect of earthworm activity on soil microbial and biochemical attributes, in particularly when soils are amended with urban sewage sludge. The purpose of this study was to evaluate the earthworm effects on biochemical and microbiological properties of a calcareous soil amended with municipal sewage sludge using Factor Analysis (FA. Materials and Methods: In the present study, the experimental treatments were sewage sludge (without and with 1.5% sewage sludge as the first factor and earthworm (no earthworm, Eiseniafoetida from epigeic group, Allolobophracaliginosa from endogeic group and a mixture of the two species as the second factor. The study was setup as 2×4 full factorial experiment arranged in a completely randomized design with three replications for each treatment under greenhouse conditions over 90 days. A calcareous soil from the 0-30 cm layer with clay loam texture was obtained from a farmland field under fallow without cultivation history for ten years. The soil was air-dried and passed through a 2-mm sieve for the experiment. Sewage sludge as the soil organic amendment was collected from Wastewater Treatment Plant in Shahrekord. Sewage sludge was air-dried and grounded to pass through a 1-mm sieve for a uniform mixture

  2. Comparison of heavy metal loads in stormwater runoff from major and minor urban roads using pollutant yield rating curves

    International Nuclear Information System (INIS)

    Davis, Brett; Birch, Gavin

    2010-01-01

    Trace metal export by stormwater runoff from a major road and local street in urban Sydney, Australia, is compared using pollutant yield rating curves derived from intensive sampling data. The event loads of copper, lead and zinc are well approximated by logarithmic relationships with respect to total event discharge owing to the reliable appearance of a first flush in pollutant mass loading from urban roads. Comparisons of the yield rating curves for these three metals show that copper and zinc export rates from the local street are comparable with that of the major road, while lead export from the local street is much higher, despite a 45-fold difference in traffic volume. The yield rating curve approach allows problematic environmental data to be presented in a simple yet meaningful manner with less information loss. - A simple method for representing data onroad runoff pollution allows comparisons among dissimilar sites and could form the basis for a pollution database.

  3. Modelling the impact of soakaway retrofits on combined sewage overflows in a 3km2 urban catchment in Copenhagen, Denmark

    DEFF Research Database (Denmark)

    Roldin, Maria Kerstin; Fryd, Ole; Jeppesen, Jan

    2012-01-01

    a more realistic scenario where only 8% of the impervious area was connected to soakaways and the reduction in CSO volume was 24%. The potential and realistic scenarios were modelled both with hydraulic coupling between soakaway and sewer, and as fully disconnected. Results show that infiltration...... step led to a potential infiltration scenario where 65% of the total impervious area was connected to soakaways, and resulted in an estimated reduction in annual sewage overflow volume of 68%. This scenario was then further developed in the third step by adding groundwater constraints, which formed...... than the fully disconnected model for the potential infiltration scenario, whereas no difference is seen between these two models in the realistic infiltration scenario. The effect of infiltration on combined sewer overflows is thus expected to be limited in the case study area. General conclusions...

  4. [Pollution load and the first flush effect of BOD5 and COD in urban runoff of Wenzhou City].

    Science.gov (United States)

    Wang, Jun; Bi, Chun-juan; Chen, Zhen-lou; Zhou, Dong

    2013-05-01

    Four typical rainfalls were monitored in two different research areas of Wenzhou Municipality. Concentrations of BOD5 and COD in six different urban runoffs were measured. In addition the event mean concentration (EMC), M (V) curve and BOD5/COD of pollutant were calculated. The results showed that concentrations of BOD5 and COD in different urban runoffs of Wenzhou ranged from ND to 69.21 mg x L(-1) and ND to 636 mg x L(-1). Concentrations of BOD5 and COD in different urban runoffs were decreasing over time, so it is greatly significant to manage the initial runoff for reducing organic pollution. Judged by EMC of BOD5 and COD in these five rainfalls, concentrations of pollutant in some urban runoffs were out of the integrated wastewater discharge standard. If these runoffs flowed into river, it would cause environmental pressure to the next level receiving water bodies. According to the M (V) curve, the first flush effect of COD in most urban runoffs was common; while the first flush effect of BOD5 was same as that of COD. The result also showed that organic pollution was serious at the beginning of runoff. The underlying surface type could affect the concentration of BOD5 and COD in urban runoff. While the results of BOD5/COD also suggested that biodegradation was considered as one of the effective ways to decrease the pollution load of organics in urban runoff, and the best management plans (BMPs) should be selected for various urban runoff types for the treatment of organic pollution.

  5. Urban microbial ecology of a freshwater estuary of Lake Michigan.

    Science.gov (United States)

    Fisher, Jenny C; Newton, Ryan J; Dila, Deborah K; McLellan, Sandra L

    Freshwater estuaries throughout the Great Lakes region receive stormwater runoff and riverine inputs from heavily urbanized population centers. While human and animal feces contained in this runoff are often the focus of source tracking investigations, non-fecal bacterial loads from soil, aerosols, urban infrastructure, and other sources are also transported to estuaries and lakes. We quantified and characterized this non-fecal urban microbial component using bacterial 16S rRNA gene sequences from sewage, stormwater, rivers, harbor/estuary, and the lake surrounding Milwaukee, WI, USA. Bacterial communities from each of these environments had a distinctive composition, but some community members were shared among environments. We used a statistical biomarker discovery tool to identify the components of the microbial community that were most strongly associated with stormwater and sewage to describe an "urban microbial signature," and measured the presence and relative abundance of these organisms in the rivers, estuary, and lake. This urban signature increased in magnitude in the estuary and harbor with increasing rainfall levels, and was more apparent in lake samples with closest proximity to the Milwaukee estuary. The dominant bacterial taxa in the urban signature were Acinetobacter, Aeromonas , and Pseudomonas , which are organisms associated with pipe infrastructure and soil and not typically found in pelagic freshwater environments. These taxa were highly abundant in stormwater and sewage, but sewage also contained a high abundance of Arcobacter and Trichococcus that appeared in lower abundance in stormwater outfalls and in trace amounts in aquatic environments. Urban signature organisms comprised 1.7% of estuary and harbor communities under baseflow conditions, 3.5% after rain, and >10% after a combined sewer overflow. With predicted increases in urbanization across the Great Lakes, further alteration of freshwater communities is likely to occur with potential

  6. Urban microbial ecology of a freshwater estuary of Lake Michigan

    Directory of Open Access Journals (Sweden)

    Jenny C. Fisher

    2015-07-01

    Full Text Available Abstract Freshwater estuaries throughout the Great Lakes region receive stormwater runoff and riverine inputs from heavily urbanized population centers. While human and animal feces contained in this runoff are often the focus of source tracking investigations, non-fecal bacterial loads from soil, aerosols, urban infrastructure, and other sources are also transported to estuaries and lakes. We quantified and characterized this non-fecal urban microbial component using bacterial 16S rRNA gene sequences from sewage, stormwater, rivers, harbor/estuary, and the lake surrounding Milwaukee, WI, USA. Bacterial communities from each of these environments had a distinctive composition, but some community members were shared among environments. We used a statistical biomarker discovery tool to identify the components of the microbial community that were most strongly associated with stormwater and sewage to describe an “urban microbial signature,” and measured the presence and relative abundance of these organisms in the rivers, estuary, and lake. This urban signature increased in magnitude in the estuary and harbor with increasing rainfall levels, and was more apparent in lake samples with closest proximity to the Milwaukee estuary. The dominant bacterial taxa in the urban signature were Acinetobacter, Aeromonas, and Pseudomonas, which are organisms associated with pipe infrastructure and soil and not typically found in pelagic freshwater environments. These taxa were highly abundant in stormwater and sewage, but sewage also contained a high abundance of Arcobacter and Trichococcus that appeared in lower abundance in stormwater outfalls and in trace amounts in aquatic environments. Urban signature organisms comprised 1.7% of estuary and harbor communities under baseflow conditions, 3.5% after rain, and >10% after a combined sewer overflow. With predicted increases in urbanization across the Great Lakes, further alteration of freshwater communities is

  7. Urban microbial ecology of a freshwater estuary of Lake Michigan

    Science.gov (United States)

    Fisher, Jenny C.; Newton, Ryan J.; Dila, Deborah K.

    2015-01-01

    Freshwater estuaries throughout the Great Lakes region receive stormwater runoff and riverine inputs from heavily urbanized population centers. While human and animal feces contained in this runoff are often the focus of source tracking investigations, non-fecal bacterial loads from soil, aerosols, urban infrastructure, and other sources are also transported to estuaries and lakes. We quantified and characterized this non-fecal urban microbial component using bacterial 16S rRNA gene sequences from sewage, stormwater, rivers, harbor/estuary, and the lake surrounding Milwaukee, WI, USA. Bacterial communities from each of these environments had a distinctive composition, but some community members were shared among environments. We used a statistical biomarker discovery tool to identify the components of the microbial community that were most strongly associated with stormwater and sewage to describe an “urban microbial signature,” and measured the presence and relative abundance of these organisms in the rivers, estuary, and lake. This urban signature increased in magnitude in the estuary and harbor with increasing rainfall levels, and was more apparent in lake samples with closest proximity to the Milwaukee estuary. The dominant bacterial taxa in the urban signature were Acinetobacter, Aeromonas, and Pseudomonas, which are organisms associated with pipe infrastructure and soil and not typically found in pelagic freshwater environments. These taxa were highly abundant in stormwater and sewage, but sewage also contained a high abundance of Arcobacter and Trichococcus that appeared in lower abundance in stormwater outfalls and in trace amounts in aquatic environments. Urban signature organisms comprised 1.7% of estuary and harbor communities under baseflow conditions, 3.5% after rain, and >10% after a combined sewer overflow. With predicted increases in urbanization across the Great Lakes, further alteration of freshwater communities is likely to occur with

  8. Modeling the Effects of Onsite Wastewater Treatment Systems on Nitrate Loads Using SWAT in an Urban Watershed of Metropolitan Atlanta.

    Science.gov (United States)

    Hoghooghi, Nahal; Radcliffe, David E; Habteselassie, Mussie Y; Jeong, Jaehak

    2017-05-01

    Onsite wastewater treatment systems (OWTSs) can be a source of nitrogen (N) pollution in both surface and ground waters. In metropolitan Atlanta, GA, >26% of homes are on OWTSs. In a previous article, we used the Soil Water Assessment Tool to model the effect of OWTSs on stream flow in the Big Haynes Creek Watershed in metropolitan Atlanta. The objective of this study was to estimate the effect of OWTSs, including failing systems, on nitrate as N (NO-N) load in the same watershed. Big Haynes Creek has a drainage area of 44 km with mainly urban land use (67%), and most of the homes use OWTSs. A USGS gauge station where stream flow was measured daily and NO-N concentrations were measured monthly was used as the outlet. The model was simulated for 12 yr. Overall, the model showed satisfactory daily stream flow and NO-N loads with Nash-Sutcliffe coefficients of 0.62 and 0.58 for the calibration period and 0.67 and 0.33 for the validation period at the outlet of the Big Haynes Watershed. Onsite wastewater treatment systems caused an average increase in NO-N load of 23% at the watershed scale and 29% at the outlet of a subbasin with the highest density of OWTSs. Failing OWTSs were estimated to be 1% of the total systems and did not have a large impact on stream flow or NO-N load. The NO-N load was 74% of the total N load in the watershed, indicating the important effect of OWTSs on stream loads in this urban watershed. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  9. Limit values in special agreements between factories and sewage works

    International Nuclear Information System (INIS)

    Lundstroem, Yrjoe

    1987-01-01

    The operation of sewage works is controlled in Finland by the water and health authorities. These authorities set special quality demands for the effluent from sewage treatment plants into the recipient. Also other wastes from treatment plants, mainly sludges, have special regulations and operational target values. Sewage works have to achieve the aim goals and limit values set. In order to fulfill the regulations, sewage works impose such limit values on factory wastewaters that there will be no problems at the treatment plants. Sewage works can act in two ways: - require the factory to operate in such a way that the limit values are not exceeded, - the factory pays a certain sum of money to the sewage works, which takes care of the whole problem. It can be said in general, that it is not possible to get rid of harmful substances by payment to the sewage works if the substances cause treatment problems or problems in sludge disposal. If the factory produces wastewater that contains a higher organic load, more suspended solids or a higher nutrient load than normal sanitary wastewater, the problem is most often solved by paying an extra fee to the sewage works

  10. Sewage sludge additive

    Science.gov (United States)

    Kalvinskas, J. J.; Mueller, W. A.; Ingham, J. D. (Inventor)

    1980-01-01

    The additive is for a raw sewage treatment process of the type where settling tanks are used for the purpose of permitting the suspended matter in the raw sewage to be settled as well as to permit adsorption of the dissolved contaminants in the water of the sewage. The sludge, which settles down to the bottom of the settling tank is extracted, pyrolyzed and activated to form activated carbon and ash which is mixed with the sewage prior to its introduction into the settling tank. The sludge does not provide all of the activated carbon and ash required for adequate treatment of the raw sewage. It is necessary to add carbon to the process and instead of expensive commercial carbon, coal is used to provide the carbon supplement.

  11. Nutrient load estimates for Manila Bay, Philippines using population data

    Science.gov (United States)

    Sotto, Lara Patricia A.; Beusen, Arthur H. W.; Villanoy, Cesar L.; Bouwman, Lex F.; Jacinto, Gil S.

    2015-06-01

    A major source of nutrient load to periodically hypoxic Manila Bay is the urban nutrient waste water flow from humans and industries to surface water. In Manila alone, the population density is as high as 19,137 people/km2. A model based on a global point source model by Morée et al. (2013) was used to estimate the contribution of the population to nitrogen and phosphorus emissions which was then used in a water transport model to estimate the nitrogen (N) and phosphorus (P) loads to Manila Bay. Seven scenarios for 2050 were tested, with varying degrees and amounts for extent of sewage treatment, and population growth rates were also included. In scenario 1, the sewage connection and treatment remains the same as 2010; in scenario 2, sewage connection is improved but the treatment is the same; in scenario 3, the sewage connection as well as treatment is improved (70% tertiary); and in scenario 4, a more realistic situation of 70% primary treatment achieved with 100% connection to pipes is tested. Scenarios 5, 6, and 7 have the same parameters as 1, 2, and 3 respectively, but with the population growth rate per province reduced to half of what was used in 1, 2, and 3. In all scenarios, a significant increase in N and P loads was observed (varying from 27% to 469% relative to 2010 values). This was found even in scenario 3 where 70% of the waste water undergoes tertiary treatment which removes 80% N and 90% P. However, the lowest increase in N and P load into the bay was achieved in scenarios 5 to 7 where population growth rate is reduced to half of 2010 values. The results suggest that aside from improving sewage treatment, the continued increase of the human population in Manila at current growth rates will be an important determinant of N and P load into Manila Bay.

  12. Impact of Urban Heat Island under the Hanoi Master Plan 2030 on Cooling Loads in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Tran Hoang Hai Nam

    2015-01-01

    Full Text Available This study aims to evaluate the influence of urban heat island (UHI under the Hanoi Master Plan 2030 on the energy consumption for space cooling in residential buildings. The weather conditions under the current and future status (master plan condition simulated in the previous study (Trihamdani et al., 2014 were used and cooling loads in all the residential buildings in Hanoi over the hottest month were estimated under the simulated current and future conditions by using the building simulation program, TRNSYS (v17. Three most typical housing types in the city were selected for the simulation. The cooling loads of respective housing types were obtained in each of the districts in Hanoi. The results show that the total cooling loads over June 2010 is approximately 683 Terajoule (TJ under the current status, but it is predicted to increase to 903 TJ under the master plan condition. The increment is largely due to the increase in number of households (203 TJ or 92%, but partially due to the increase in urban temperature, i.e. UHI effect (17 TJ or 8%. The increments in new built-up areas were found to be larger than those in existing built-up areas. The cooling load in apartment is approximately half of that in detached house, which is approximately half of that in row house. Moreover, it was seen that although sensible cooling loads increased with the increase in outdoor temperature, the latent cooling loads decreased due to the decrease in absolute humidity and the increase in air temperature.

  13. Electrodialytic recovery of phosphorus from chemically precipitated sewage sludge ashes

    DEFF Research Database (Denmark)

    Parés Viader, Raimon; Jensen, Pernille Erland; Ottosen, Lisbeth M.

    Phosphorus scarcity requires improved recover and reuse of urban sources; the recycling of this nutrient from sewage sludge has become increasingly important in the last years. Using an innovative electrodialytic process, the present study shows the potential for P separation from Fe and Al...... precipitated sewage sludge ash using this technique, with a recovery rate of around 70%. Furthermore, heavy metals were removed from the phosphorous fraction, producing a pure and safe phosphorus source in the end....

  14. Electrodialytic recovery of phosphorus from chemically precipitated sewage sludge ashes

    DEFF Research Database (Denmark)

    Viader, Raimon Parés; Erland Jensen, Pernille; Ottosen, Lisbeth M.

    Phosphorus scarcity requires improved recover and reuse of urban sources; the recycling of this nutrient from sewage sludge has become increasingly important in the last years. Using an innovative electrodialytic process, the present study shows the potential for P separation from Fe and Al...... precipitated sewage sludge ash using this technique, with a recovery rate of around 70%. Furthermore, heavy metals were removed from the phosphorous fraction, producing a pure and safe phosphorus source in the end...

  15. The existing state of sewage sludge containing radioactive substances

    International Nuclear Information System (INIS)

    Shirasaki, Makoto; Hisaoka, Natsuki

    2012-01-01

    Radioactive substances were discharged over a wide range from the accident of the Fukushima Daiichi Nuclear Station of Tokyo Electric Power Company. As a result, in sewer system, especially in the combined sewer system that jointly collects rainwater and sewage, radioactive substances accumulated on the surface of urban areas were transferred together with rainwater to sewage plants and accumulated there. In the process of further treatment, radioactive substances were transferred to and concentrated in sewage sludge, and a high concentration of radioactive substances were detected in incineration ash. For this reason, some sewage plants still continuously store dewatered sludge, incinerator ash, etc. This paper introduces the current state of waste treatment from the published data from each local government in Tohoku and Kanto districts. As for the sewer, which is essential as a lifeline, the Ministry of Land, Infrastructure, Transport and Tourism, together with the Japan Sewage Works Association, established 'Investigative Commission on Radioactive Substance Countermeasures in Sewerage System.' This group grasped the damage situation due to radioactive substances, and summarized the measures to be taken by sewage managers, such as the storage method for sewage sludge containing radioactive substances as well as the method for the volume reduction of sewage sludge. (O.A.)

  16. Contribution of hospital effluents to the load of pharmaceuticals in urban wastewaters: identification of ecologically relevant pharmaceuticals.

    Science.gov (United States)

    Santos, Lúcia H M L M; Gros, Meritxell; Rodriguez-Mozaz, Sara; Delerue-Matos, Cristina; Pena, Angelina; Barceló, Damià; Montenegro, M Conceição B S M

    2013-09-01

    The impact of effluent wastewaters from four different hospitals: a university (1456 beds), a general (350 beds), a pediatric (110 beds) and a maternity hospital (96 beds), which are conveyed to the same wastewater treatment plant (WWTP), was evaluated in the receiving urban wastewaters. The occurrence of 78 pharmaceuticals belonging to several therapeutic classes was assessed in hospital effluents and WWTP wastewaters (influent and effluent) as well as the contribution of each hospital in WWTP influent in terms of pharmaceutical load. Results indicate that pharmaceuticals are widespread pollutants in both hospital and urban wastewaters. The contribution of hospitals to the input of pharmaceuticals in urban wastewaters widely varies, according to their dimension. The estimated total mass loadings were 306 g d(-1) for the university hospital, 155 g d(-1) for the general one, 14 g d(-1) for the pediatric hospital and 1.5 g d(-1) for the maternity hospital, showing that the biggest hospitals have a greater contribution to the total mass load of pharmaceuticals. Furthermore, analysis of individual contributions of each therapeutic group showed that NSAIDs, analgesics and antibiotics are among the groups with the highest inputs. Removal efficiency can go from over 90% for pharmaceuticals like acetaminophen and ibuprofen to not removal for β-blockers and salbutamol. Total mass load of pharmaceuticals into receiving surface waters was estimated between 5 and 14 g/d/1000 inhabitants. Finally, the environmental risk posed by pharmaceuticals detected in hospital and WWTP effluents was assessed by means of hazard quotients toward different trophic levels (algae, daphnids and fish). Several pharmaceuticals present in the different matrices were identified as potentially hazardous to aquatic organisms, showing that especial attention should be paid to antibiotics such as ciprofloxacin, ofloxacin, sulfamethoxazole, azithromycin and clarithromycin, since their hazard quotients

  17. Return of phosphorus in agricultural residues and urban sewage sludge to soil using biochar from low-temperature gasification as fertilizer product

    DEFF Research Database (Denmark)

    Müller-Stöver, Dorette Sophie; Jensen, Lars Stoumann; Grønlund, Mette

    The return of residual products from bioenergy generation to soils is a step towards closing nutrient cycles, which is especially important for nutrients produced from non-renewable resources such as phosphorus (P). Low-temperature gasification is an innovative process efficiently generating ener...... from different biomass fuels, such as agricultural residues and waste streams, and at the same time producing a biochar product potentially valuable for soil amendment. In pot experiments, different residual products originating from low-temperature gasification were tested for their P......-fertilizing potential with spring barley as a test crop. Biochar resulting from gasification of pure wheat straw showed the best P fertilizer value, however, because of the low P content, extremely high amounts had to be applied when crop P demand should be met, which came along with an over-fertilization of potassium...... (K). Gasification of pure sewage sludge with a high Fe and Al content practically eliminated its P fertilizer value, while co-gasification of sludge lower in Fe and Al together with wheat straw resulted in a biochar product with only somewhat reduced P availability and improved P/K ratio...

  18. Physicochemical and bacteriological characterization of raw sewage from the Meknes region Morocco

    Science.gov (United States)

    Hassan, Ouallal; Hamzaoui Najia, El; Mohammed, Sbiti; Mohammed, Machkor; Lahcen, Messaoudi; Mohamed, Azrour

    2018-05-01

    The region of Meknes suffers from a significant delay in the water sector, including sewage treatment. The Urban waste water in the region originates from various activities; households, industry, agriculture and hospital. These waters are released in to nature without any treatment, which constitutes a serious risk for the environment. The objective of this research is to characterize the physicochemical and bacteriological pollution of the three sewage collectors of the Meknes region (Aïn Choubbik, Oued Ouislane and Aïn Taoujdate). Indeed, the pollution parameters; biological and chemical oxygen demand are abnormally high, which indicates clearly that waste waters is rich of reducing or oxidizing organic materials. Ammonium, nitrogen, phosphorus and heavy metals concentrations exceed the limit values. So these waters are classified as bad or very bad quality. On the one hand, the presence of a large bacterial load indicates fecal contamination. The total coliform, fecal coliform and fecal streptococci levels are high exceeding exceed the values specified the WHO guidelines and the Moroccan standards. This situation is likely to cause serious and irreparable damage to the environment groundwater. To counter this, make the necessary investment in sewage treatment and other remedial measures is key to preventing pollution and its spread.

  19. Retrofitting impervious urban infrastructure with green technology for rainfall-runoff restoration, indirect reuse and pollution load reduction.

    Science.gov (United States)

    Sansalone, John; Raje, Saurabh; Kertesz, Ruben; Maccarone, Kerrilynn; Seltzer, Karl; Siminari, Michele; Simms, Peter; Wood, Brandon

    2013-12-01

    The built environs alter hydrology and water resource chemistry. Florida is subject to nutrient criteria and is promulgating "no-net-load-increase" criteria for runoff and constituents (nutrients and particulate matter, PM). With such criteria, green infrastructure, hydrologic restoration, indirect reuse and source control are potential design solutions. The study simulates runoff and constituent load control through urban source area re-design to provide long-term "no-net-load-increases". A long-term continuous simulation of pre- and post-development response for an existing surface parking facility is quantified. Retrofits include a biofiltration area reactor (BAR) for hydrologic and denitrification control. A linear infiltration reactor (LIR) of cementitious permeable pavement (CPP) provides infiltration, adsorption and filtration. Pavement cleaning provided source control. Simulation of climate and source area data indicates re-design achieves "no-net-load-increases" at lower costs compared to standard construction. The retrofit system yields lower cost per nutrient load treated compared to Best Management Practices (BMPs). Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  1. Characterization, treatment and releases of PBDEs and PAHs in a typical municipal sewage treatment plant situated beside an urban river, East China.

    Science.gov (United States)

    Wang, Xiaowei; Xi, Beidou; Huo, Shouliang; Sun, Wenjun; Pan, Hongwei; Zhang, Jingtian; Ren, Yuqing; Liu, Hongliang

    2013-07-01

    Characterization, treatment and releases of eight polybrominated diphenyl ethers (PBDEs) congeners and sixteen polycyclic aromatic hydrocarbons (PAHs) in wastewater were evaluated along the treatment processes of a typical secondary treatment municipal sewage treatment plant (STP) (in Hefei City) situated the beside Nanfei River, East China. The findings showed that the average concentrations of the total PBDEs in raw wastewater and treated effluent were 188.578 and 36.884 ng/L respectively. Brominated diphenyl ether (BDE) 209 congener, the predominant PBDE in the STP and Nanfei River, could be related to the discharge of car-industry-derived wastes. For PAHs, the average concentrations in raw wastewater and treated effluent were 5758.8 and 2240.4 ng/L respectively, with naphthalene, benzo[a]pyrene and indeno[1,2,3-c,d]pyrene being detected at the highest concentrations. PAHs mainly originate from the combustion of biomass/coal and petroleum. The STP reduced about 80% of the PBDEs and 61% of the PAHs, which were eliminated mainly by sedimentation processes. The removal rates of PBDEs/PAHs increased with the increase of their solid-water partitioning coefficients. Accordingly, the STP's effluent, containing some PBDE congeners (e.g., BDE 47, 99 and 209, etc.) and low-molecular-weight PAHs, could be an important contributor of these contaminants' input to Nanfei River. It resulted in a significant increase of PBDE/PAH concentrations and PAH toxicological risk in the river water downstream. About 4.040 kg/yr of PBDEs and 245.324 kg/yr of PAHs could be released into the Nanfei River. The current conventional wastewater treatment processes should be improved to remove the relatively low-molecular-weight PBDEs/PAHs more effectively.

  2. Contribution and loading estimation of organochlorine pesticides from rain and canopy throughfall to runoff in an urban environment.

    Science.gov (United States)

    Zhang, Wei; Ye, Youbin; Tong, Yindong; Ou, Langbo; Hu, Dan; Wang, Xuejun

    2011-01-30

    Concentrations of OCPs in rain, canopy throughfall, and runoff water were measured in the Beijing metropolitan area during the rainy seasons from 2006 to 2007. This study was conducted to calculate the fluxes of OCPs in rain and canopy throughfall, as well as their contributions to runoff. At urban sites, the contribution of HCB and ΣHCHs from rainfall accounted for approximately 50% of the mass in runoff. At the site with significant coverage of landscaping trees, the HCB, ΣHCHs, and ΣDDTs from the net canopy throughfall accounted for approximately 10% of the mass in the runoff. Based on the data obtained in this study, loadings of OCPs (in μg) in rain, net canopy throughfall, and runoff water were calculated. The input of OCPs from rain and canopy throughfall water accounted for a significant portion of urban runoff. In cities undergoing rapid urban sprawl, monitoring and control of the transport of OCPs in urban runoff are essential for effective control of environmental hazards in surface water bodies. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Sewage sludges compost and organic fraction urban solid waste from selective collection; Compostaje de lodos de depuradora y FORSU procedente de recogida selectiva

    Energy Technology Data Exchange (ETDEWEB)

    Chica, A.; Diaz, M. M.; Mohedo, J.

    2001-07-01

    The organic fraction of urban solid waste (FORSU) from selective collection has been analysed to make a good quality compost for soils an agricultural use. Different mixtures of FORSU, sludge from the municipal water treatment plant, and pruning garden has been composted in turned windrow. The composting process and the obtained refined compost were characterised. The results on evolution of pH, conductivity, C/N relation, P, metals,-organic matter and recovery yield were related. (Author) 15 refs.

  4. Comparison of Health Risk Assessments of Heavy Metals and As in Sewage Sludge from Wastewater Treatment Plants (WWTPs for Adults and Children in the Urban District of Taiyuan, China

    Directory of Open Access Journals (Sweden)

    Baoling Duan

    2017-10-01

    Full Text Available Abstract: To compare the human health risk of heavy metals and As in sewage sludge between adults and children, samples were collected from five wastewater treatment plants (WWTPs located in the urban district of Taiyuan, the capital of Shanxi. Heavy metals and As in sewage sludge can be ranked according to the mean concentration in the following order: Cu > Cr > Zn > Pb > As > Hg > Cd. Compared with the concentration limit set by different countries, the heavy metals contents in sewage sludge were all within the standard limits, except for the content of As, which was higher than the threshold limit established by Canada. A health risk assessment recommended by the United States Environmental Protection Agency (USEPA was used to compare the non-cancer risk and cancer risk between adults and children. Based on the mean and 95% upper confidence limit (UCL of the average daily dose (ADD, heavy metals and As can be ranked in the order of Cu > Cr > Zn > Pb > As > Hg > Cd for adults, and Cu > Cr > Zn > Pb > Hg > As > Cd for children. Moreover, results of ADDingest and ADDinhale indicated that ingestion was the main pathway for heavy metals and As exposure for both adults and children, and the sum of ADD implied that the exposure to all heavy metals and As for children was 8.65 and 9.93 times higher, respectively, than that for adults according to the mean and 95% UCL. For the non-carcinogenic risk, according to the hazard quotient (HQ, the risk of Cu, Hg and Cr was higher than the risk of Zn and Pb. The hazard index (HI for adults was 0.144 and 0.208 for the mean and 95% UCL, which was less than the limit value of 1; for children, the HI was 1.26 and 2.25, which is higher than the limit value of 1. This result indicated that children had non-carcinogenic risk, but adults did not. Furthermore, ingestion was the main pathway for non-carcinogenic risk exposure by the HQingest and HQinhale. For the carcinogenic risk, Cd and As were classified as

  5. Comparison of Health Risk Assessments of Heavy Metals and As in Sewage Sludge from Wastewater Treatment Plants (WWTPs) for Adults and Children in the Urban District of Taiyuan, China.

    Science.gov (United States)

    Duan, Baoling; Zhang, Wuping; Zheng, Haixia; Wu, Chunyan; Zhang, Qiang; Bu, Yushan

    2017-10-08

    Abstract : To compare the human health risk of heavy metals and As in sewage sludge between adults and children, samples were collected from five wastewater treatment plants (WWTPs) located in the urban district of Taiyuan, the capital of Shanxi. Heavy metals and As in sewage sludge can be ranked according to the mean concentration in the following order: Cu > Cr > Zn > Pb > As > Hg > Cd. Compared with the concentration limit set by different countries, the heavy metals contents in sewage sludge were all within the standard limits, except for the content of As, which was higher than the threshold limit established by Canada. A health risk assessment recommended by the United States Environmental Protection Agency (USEPA) was used to compare the non-cancer risk and cancer risk between adults and children. Based on the mean and 95% upper confidence limit (UCL) of the average daily dose (ADD), heavy metals and As can be ranked in the order of Cu > Cr > Zn > Pb > As > Hg > Cd for adults, and Cu > Cr > Zn > Pb > Hg > As > Cd for children. Moreover, results of ADD ingest and ADD inhale indicated that ingestion was the main pathway for heavy metals and As exposure for both adults and children, and the sum of ADD implied that the exposure to all heavy metals and As for children was 8.65 and 9.93 times higher, respectively, than that for adults according to the mean and 95% UCL. For the non-carcinogenic risk, according to the hazard quotient (HQ), the risk of Cu, Hg and Cr was higher than the risk of Zn and Pb. The hazard index (HI) for adults was 0.144 and 0.208 for the mean and 95% UCL, which was less than the limit value of 1; for children, the HI was 1.26 and 2.25, which is higher than the limit value of 1. This result indicated that children had non-carcinogenic risk, but adults did not. Furthermore, ingestion was the main pathway for non-carcinogenic risk exposure by the HQ ingest and HQ inhale . For the carcinogenic risk, Cd and As were classified as carcinogenic

  6. Monitoring of β-d-Galactosidase Activity as a Surrogate Parameter for Rapid Detection of Sewage Contamination in Urban Recreational Water

    Directory of Open Access Journals (Sweden)

    Ingun Tryland

    2016-02-01

    Full Text Available Simple, automated methods are required for rapid detection of wastewater contamination in urban recreational water. The activity of the enzyme β-d-galactosidase (GAL can rapidly (<2 h be measured by field instruments, or a fully automated instrument, and was evaluated as a potential surrogate parameter for estimating the level of fecal contamination in urban waters. The GAL-activity in rivers, affected by combined sewer overflows, increased significantly during heavy rainfall, and the increase in GAL-activity correlated well with the increase in fecal indicator bacteria. The GAL activity in human feces (n = 14 was high (mean activity 7 × 107 ppb MU/hour and stable (1 LOG10 variation, while the numbers of Escherichia coli and intestinal enterococci varied by >5 LOG10. Furthermore, the GAL-activity per gram feces from birds, sheep and cattle was 2–3 LOG10 lower than the activity from human feces, indicating that high GAL-activity in water may reflect human fecal pollution more than the total fecal pollution. The rapid method can only be used to quantify high levels of human fecal pollution, corresponding to about 0.1 mg human feces/liter (or 103 E. coli/100 mL, since below this limit GAL-activity from non-fecal environmental sources may interfere.

  7. THE ANALYSIS OF SEWAGE SYSTEM INFLUENCE ON RECEIVERS

    Directory of Open Access Journals (Sweden)

    Kamil Pluta

    2015-11-01

    Full Text Available Reducing waste water discharges to the receiver is now one of the most important activities to ensure the protection of surface waters. This is caused mainly by progressive urbanization and increasing impervious surfaces. Discharge of sewage with a large load of pollutants affect the receivers in a negative way. The quality of waste water varies and depends on many factors, but above all, it is closely linked with sewer system applied to the drainage catchment. The article presents a comparative analysis of the environmental impact of three basic sewer systems: combined, separate and semi-separate. The analysis was performed for a typical urban catchment, using the average concentration of the basic indicators of pollution, which total suspended solids, nitrogen and phosphorus, COD, BOD5, selected heavy metals are merked. The results concluded that each of these sewer systems characterized by varying environmental impacts depending on the indicator of pollution. The best of today available technical solutions seem to be semi-separate sewer system, using the storage tank with the control in real time (RTC for controlling the flow.

  8. Distribution and disinfection of bacterial loadings associated with particulate matter fractions transported in urban wet weather flows.

    Science.gov (United States)

    Dickenson, Joshua A; Sansalone, John J

    2012-12-15

    Urban runoff is a resource for reuse water. However, runoff transports indicator and pathogenic organisms which are mobilized from sources of fecal contamination. These organisms are entrained with particulate matter (PM) that can serve as a mobile substrate for these organisms. Within a framework of additional treatment for reuse of treated runoff which requires the management of PM inventories in unit operations and drainage systems there is a need to characterize organism distributions on PM and the disinfection potential thereof. This study quantifies total coliform, Escherichia coli, fecal streptococcus, and enterococcus generated from 25 runoff events. With the ubiquity and hetero-dispersivity of PM in urban runoff this study examines organism distributions for suspended, settleable and sediment PM fractions differentiated based on PM size and transport functionality. Hypochlorite is applied in batch to elaborate inactivation of PM-associated organisms for each PM fraction. Results indicate that urban runoff bacterial loadings of indicator organisms exceed U.S. wastewater reuse, recreational contact, and Australian runoff reuse criteria as comparative metrics. All monitored events exceeded the Australian runoff reuse criteria for E. coli in non-potable residential and unrestricted access systems. In PM-differentiated events, bacteriological mobilization primarily occurred in the suspended PM fraction. However, sediment PM shielded PM-associated coliforms at all hypochlorite doses, whereas suspended and settleable PM fractions provide less shielding resulting in higher inactivation by hypochlorite. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Parasitic helminth load in urban waste-water of Kenitra City, Morocco

    African Journals Online (AJOL)

    Waste-waters of Kenitra City are rejected without any preliminary treatment in the receiving medium (Sebou River, Fouarat Lake). A small fraction is used to irrigate crops in the peri-urban area of Kenitra City. The parasitological characterization revealed an average parasitic helminth egg concentration of 25.07 per liter ...

  10. Effects of Urban Wastewater Loading on Macro- and Meio-infauna ...

    African Journals Online (AJOL)

    Benthic infaunal community studies are a useful tool to determine the health of an ecosystem. In this study, an unbalanced ACI (After Control/Impact) design was used to compare the infaunal community structure in a contaminated peri-urban mangrove swamp with two nearby pristine mangroves of similar ecological traits in ...

  11. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment—A review

    International Nuclear Information System (INIS)

    Verlicchi, P.; Al Aukidy, M.; Zambello, E.

    2012-01-01

    This review focuses on 118 pharmaceuticals, belonging to seventeen different therapeutic classes, detected in raw urban wastewater and effluent from an activated sludge system, a usual treatment adopted for urban wastewaters worldwide prior to final discharge into surface water bodies. Data pertaining to 244 conventional activated sludge systems and 20 membrane biological reactors are analysed and the observed ranges of variability of each selected compound in their influent and effluent reported, with particular reference to the substances detected most frequently and in higher concentrations. A snapshot of the ability of these systems to remove such compounds is provided by comparing their global removal efficiencies for each substance. Where possible, the study then evaluates the average daily mass load of the majority of detected pharmaceuticals exiting the secondary treatment step. The final part of the review provides an assessment of the environmental risk posed by their presence in the secondary effluent by means of the risk quotient that is the ratio between the average pharmaceutical concentration measured in the secondary effluent and the predicted no-effect concentration. Finally, mass load rankings of the compounds under review are compared with those based on their risk level. This analysis shows that the highest amounts discharged through secondary effluent pertain to one antihypertensive, and several beta-blockers and analgesics/anti-inflammatories, while the highest risk is posed by antibiotics and several psychiatric drugs and analgesics/anti-inflammatories. These results are reported with a view to aiding scientists and administrators in planning measures aiming to reduce the impact of treated urban wastewater discharge into surface water bodies. - Highlights: ► The review refers to 118 pharmaceuticals occurring in raw and treated wastewaters. ► Data from 264 municipal WWTPs with a CAS or an MBR were analysed. ► The removal rates achieved

  12. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment-A review

    Energy Technology Data Exchange (ETDEWEB)

    Verlicchi, P., E-mail: paola.verlicchi@unife.it [Dept. of Engineering, University of Ferrara, Via Saragat 1, I-44122 Ferrara (Italy); Terra and AcquaTech Technopoles, Via Borsari 46, I-44121 Ferrara (Italy); Al Aukidy, M., E-mail: mustafakether.alaukidi@unife.it [Dept. of Engineering, University of Ferrara, Via Saragat 1, I-44122 Ferrara (Italy); Zambello, E., E-mail: elena.zambello@unife.it [Dept. of Engineering, University of Ferrara, Via Saragat 1, I-44122 Ferrara (Italy); Terra and AcquaTech Technopoles, Via Borsari 46, I-44121 Ferrara (Italy)

    2012-07-01

    This review focuses on 118 pharmaceuticals, belonging to seventeen different therapeutic classes, detected in raw urban wastewater and effluent from an activated sludge system, a usual treatment adopted for urban wastewaters worldwide prior to final discharge into surface water bodies. Data pertaining to 244 conventional activated sludge systems and 20 membrane biological reactors are analysed and the observed ranges of variability of each selected compound in their influent and effluent reported, with particular reference to the substances detected most frequently and in higher concentrations. A snapshot of the ability of these systems to remove such compounds is provided by comparing their global removal efficiencies for each substance. Where possible, the study then evaluates the average daily mass load of the majority of detected pharmaceuticals exiting the secondary treatment step. The final part of the review provides an assessment of the environmental risk posed by their presence in the secondary effluent by means of the risk quotient that is the ratio between the average pharmaceutical concentration measured in the secondary effluent and the predicted no-effect concentration. Finally, mass load rankings of the compounds under review are compared with those based on their risk level. This analysis shows that the highest amounts discharged through secondary effluent pertain to one antihypertensive, and several beta-blockers and analgesics/anti-inflammatories, while the highest risk is posed by antibiotics and several psychiatric drugs and analgesics/anti-inflammatories. These results are reported with a view to aiding scientists and administrators in planning measures aiming to reduce the impact of treated urban wastewater discharge into surface water bodies. - Highlights: Black-Right-Pointing-Pointer The review refers to 118 pharmaceuticals occurring in raw and treated wastewaters. Black-Right-Pointing-Pointer Data from 264 municipal WWTPs with a CAS or an

  13. Analysis of Organic and Inorganic Contaminants in Dried Sewage Sludge and By-Products of Dried Sewage Sludge Gasification

    Directory of Open Access Journals (Sweden)

    Sebastian Werle

    2014-01-01

    Full Text Available Organic and inorganic contaminants in sewage sludge may cause their presence also in the by-products formed during gasification processes. Thus, this paper presents multidirectional chemical instrumental activation analyses of dried sewage sludge as well as both solid (ash, char coal and liquid (tar by-products formed during sewage gasification in a fixed bed reactor which was carried out to assess the extent of that phenomenon. Significant differences were observed in the type of contaminants present in the solid and liquid by-products from the dried sewage sludge gasification. Except for heavy metals, the characteristics of the contaminants in the by-products, irrespective of their form (solid and liquid, were different from those initially determined in the sewage sludge. It has been found that gasification promotes the migration of certain valuable inorganic compounds from sewage sludge into solid by-products which might be recovered. On the other hand, the liquid by-products resulting from sewage sludge gasification require a separate process for their treatment or disposal due to their considerable loading with toxic and hazardous organic compounds (phenols and their derivatives.

  14. Disinfection of sewage

    International Nuclear Information System (INIS)

    Arenas, J.

    1984-01-01

    Laboratory studies at IPEN and SEDAPAL have shown the effectiveness disinfection of sewage by means of ionizing radiations. A dose of 1 Kilo Gray reduces the coliforms and salmonella under the permissible levels. This method should allow to use again the liquids in the agriculture or its disposal like sea nutrient

  15. Plumbing and Sewage Disposal.

    Science.gov (United States)

    Sutliff, Ronald D.; And Others

    This self-study course is designed to familiarize Marine enlisted personnel with the principles of plumbing and sewage disposal used by Marine Hygiene Equipment Operators to perform their mission. The course contains three study units. Each study unit begins with a general objective, which is a statement of what the student should learn from the…

  16. Basic Sewage Treatment Operation.

    Science.gov (United States)

    Ontario Ministry of the Environment, Toronto.

    This manual was developed for use at workshops designed to introduce operators to the fundamentals of sewage plant operation. The course consists of lecture-discussions and hands-on activities. Each of the lessons has clearly stated behavioral objectives to tell the trainee what he should know or do after completing that topic. Areas covered in…

  17. Solar electricity: An effective asset to supply urban loads in hot climates

    Science.gov (United States)

    Robert, Fabien Chidanand; Gopalan, Sundararaman

    2018-04-01

    While human population has been multiplied by four in the last hundred years, the world energy consumption was multiplied by ten. The common method of using fossil fuels to provide energy and electricity has dangerously disturbed nature's and climate's balance. It has become urgent and crucial to find sustainable and eco-friendly alternatives to preserve a livable environment with unpolluted air and water. Renewable energy is the unique eco-friendly opportunity known today. The main challenge of using renewable energy is to ensure the constant balance of electricity demand and generation on the electrical grid. This paper investigates whether the solar electricity generation is correlated with the urban electricity consumption in hot climates. The solar generation and total consumption have been compared for three cities in Florida. The hourly solar generation has been found to be highly correlated with the consumption that occurs 6 h later, while the monthly solar generation is correlated with the monthly energy consumption. Producing 30% of the electricity using solar energy has been found to compensate partly for the monthly variation in the urban electricity demand. In addition, if 30% of the world electricity is produced using solar, global CO2 emissions would be reduced by 11.7% (14.6% for India). Thus, generating 30% solar electricity represents a valuable asset for urban areas situated in hot climates, reducing the need for electrical operating reserve, providing local supply with minimal transmission losses, but above all reducing the need for fossil fuel electricity and reducing global CO2 emission.

  18. Characterizing Ecosystem and Watershed Response to Atmospheric Loading at the Urban Fringe

    Science.gov (United States)

    Curto, V.; Lopez, S.; Hogue, T.; Rademacher, L.

    2006-12-01

    The southern California region, although highly urbanized and densely populated, is also characterized by steep mountain ranges with extensive forests and diverse ecosystems. Growing population pressure in the region has forced continuing development at the urban fringe. The large mountain systems situated on the windward side of the Los Angeles basin experience high atmospheric nitrogen deposition rates from various urban pollutants. Arroyo Seco, a watershed located on the eastern edge of the Los Angeles basin, is no exception to this trend. The present study uses hydrologic and geochemical data to assess current watershed dynamics and ecosystem responses to the impacts of regional urbanization. The Arroyo Seco stream runs through a deeply incised canyon originating in the San Gabriel Mountains and draining into the Los Angeles River. The current riparian habitat, which comprises only 15 percent of the total land cover within the watershed, contains over 705 species of plants and animals. We focused our studies on the upper reaches of the basin (~18 square miles), which remains undeveloped and consists primarily of chaparral and evergreen forests. This portion of the watershed has an average watershed slope of approximately 6 percent and relatively porous soils. However, estimated runoff ratio from the existing USGS gage and local precipitation gages indicates fairly high runoff (discharge/precipitation ratio of 0.29). Weekly stream samples have been collected over a several year period and analyzed for standard geochemical constituents and stable isotopes to assess deposition impacts on ecosystem function and overall watershed behavior. Stable isotopes of water measured in the weekly Arroyo Seco stream samples deviate from the global meteoric water line (GMWL), particularly during summer months. High evaporative rates in the summer may be responsible for the distinct summer pattern and overall deviation from the GMWL of stream isotope values. An

  19. Will urban expansion lead to an increase in future water pollution loads?--a preliminary investigation of the Haihe River Basin in northeastern China.

    Science.gov (United States)

    Dong, Yang; Liu, Yi; Chen, Jining

    2014-01-01

    Urban expansion is a major driving force changing regional hydrology and nonpoint source pollution. The Haihe River Basin, the political, economic, and cultural center of northeastern China, has undergone rapid urbanization in recent decades. To investigate the consequences of future urban sprawl on nonpoint source water pollutant emissions in the river basin, the urban sprawl in 2030 was estimated, and the annual runoff and nonpoint source pollution in the Haihe River basin were simulated. The Integrated Model of Non-Point Sources Pollution Processes (IMPULSE) was used to simulate the effects of urban sprawl on nonpoint source pollution emissions. The outcomes indicated that the urban expansion through 2030 increased the nonpoint source total nitrogen (TN), total phosphorous (TP), and chemical oxygen demand (COD) emissions by 8.08, 0.14, and 149.57 kg/km(2), respectively. Compared to 2008, the total nonpoint emissions rose by 15.33, 0.57, and 12.39 %, respectively. Twelve percent of the 25 cities in the basin would increase by more than 50 % in nonpoint source TN and COD emissions in 2030. In particular, the nonpoint source TN emissions in Xinxiang, Jiaozuo, and Puyang would rise by 73.31, 67.25, and 58.61 %, and the nonpoint source COD emissions in these cities would rise by 74.02, 51.99, and 53.27 %, respectively. The point source pollution emissions in 2008 and 2030 were also estimated to explore the effects of urban sprawl on total water pollution loads. Urban sprawl through 2030 would bring significant structural changes of total TN, TP, and COD emissions for each city in the area. The results of this study could provide insights into the effects of urbanization in the study area and the methods could help to recognize the role that future urban sprawl plays in the total water pollution loads in the water quality management process.

  20. Seasonal and spatial variations of PPCP occurrence, removal and mass loading in three wastewater treatment plants located in different urbanization areas in Xiamen, China

    International Nuclear Information System (INIS)

    Sun, Qian; Li, Mingyue; Ma, Cong; Chen, Xiangqiang; Xie, Xiaoqing; Yu, Chang-Ping

    2016-01-01

    The occurrence and fate of 48 pharmaceuticals and personal care products (PPCPs) in three wastewater treatment plants (WWTPs) located in different urbanization areas in Xiamen, China was investigated over one year. Results showed that PPCPs were widely detected, but the major PPCPs in the influent, effluent, and sludge were different. Spatial and seasonal variations of PPCP levels in the influent and sludge were observed. The removal efficiencies for most PPCPs were similar among the three WWTPs, although they employed different biological treatment processes. Furthermore, the mass loadings per inhabitant of most pharmaceuticals had a positive correlation with the urbanization levels, indicating that most pharmaceutical usage was higher in the urban core compared to the suburban zones. The total mass loadings of all the 48 PPCPs in the effluent and waste sludge showed close proportions, which suggested the importance of proper waste sludge disposal to prevent a large quantity of PPCPs from entering the environment. - Highlights: • The major components in the influent, effluent, and sludge were different. • Removal rates were similar for most PPCPs under different treatment processes. • Pharmaceutical usage was higher in the urban core compared to suburban zones. • Effluent and sludge shared close proportions for PPCP releasing to the environment. - The total mass loadings of PPCPs per inhabitant in the influent, effluent and waste sludge of WWTPs were higher in the urban core compared to the suburban zones.

  1. System simulation for an untreated sewage source heat pump (USSHP) in winter

    Science.gov (United States)

    Qin, Na; Hao, Peng Z.

    2017-01-01

    The paper discusses the system characteristics of an untreated sewage source heat pump in winter. In this system, the sewage enters into the evaporator directly. The variable parameters to control the system contain the sewage temperature at evaporator inlet and the water temperature at condenser inlet. It is found that most parameters, except the condensation heat transfer coefficient, change in the form of sine wave the same as the sewage temperature at inlet. The heating load and consumed power are 12.9kW and 3.45kW when the sewage temperature at inlet is 13°C. COP is about 3.75 in the range of the sewage temperature at inlet of 12-13°C.

  2. Lichens as indicators for immission load in the urban region of Frankfurt/M

    Energy Technology Data Exchange (ETDEWEB)

    Kirschbaum, U; Klee, R; Steubing, L

    1971-01-01

    The plotting of a map showing the natural lichen growth on trees has been undertaken in Frankfurt, and, in addition, the degree of air pollution has also been tested by means of Parmelia physodes planted at different measuring points. The city center is characterized by a complete absence of lichen which shows that the air in this zone is very unhealthy. In contrast to this, the middle and outer pollution control zones are to be considered as a residential district offering better hygienic conditions. The limits of the zone completely devoid of lichen is characterized in Frankfurt by an average SO/sub 2/ load of 0.11 mg SO/sub 2//m/sup 3/, and by a high dust concentration. 20 references.

  3. Toxicity and pollutant impact analysis in an urban river due to combined sewer overflows loads.

    Science.gov (United States)

    Casadio, A; Maglionico, M; Bolognesi, A; Artina, S

    2010-01-01

    The Navile Channel (Bologna, Italy) is an ancient artificial water course derived from the Reno river. It is the main receiving water body for the urban catchment of Bologna sewer systems and also for the Waste Water Treatment Plant (WWTP) main outlet. The aim of this work is to evaluate the Combined Sewer Overflows (CSOs) impact on Navile Channel's water quality. In order to collect Navile flow and water quality data in both dry and wet weather conditions, two measuring and sampling stations were installed, right upstream and downstream the WWTP outflow. The study shows that even in case of low intensity rain events, CSOs have a significant effect on both water quantity and quality, spilling a considerable amount of pollutants into the Navile Channel and presenting also acute toxicity effects. The collected data shown a good correlations between the concentrations of TSS and of chemical compounds analyzed, suggesting that the most part of such substances is attached to suspended solids. Resulting toxicity values are fairly high in both measuring points and seem to confirm synergistic interactions between heavy metals.

  4. Stormwater quality and pollution loading from an urban residential catchment in Johor, Malaysia.

    Science.gov (United States)

    Nazahiyah, R; Yusop, Z; Abustan, I

    2007-01-01

    Sampling of urban runoff was carried out in a small catchment, which represents a residential area (3.34 ha) in Skudai, Johor. One hundred and seventeen runoff samples from ten storm events were analysed. Runoff quality showed large variations in concentrations during storms, especially for SS, BOD5 and COD. Concentrations of NO3-N, NO2-N, NH3-N, and P were also high. Lead (Pb) was also detected but the levels were low (<0.001 mg/L). In general, the river quality is badly polluted and falls in Class V based on the Malaysian Interim National Water Quality Standards. Event mean concentrations for all parameters were found to vary greatly between storms. The values (mg/L) were BOD5 (72), COD (325), SS (386), NO3-N (2.5), NO2-N (0.58), NH3-N (6.8), P (3.4), respectively. First flush phenomena were observed for BOD, COD, SS, NO3-N, NH3-N and P. The first 20-30% of the runoff volume evacuated between 20-59% BOD, 15-69% COD, 15-78% SS, 14-49% NO3-N, 14-19% NO2-N, 23-53% NH3-N and 23-43% P.

  5. Sewage sludge irradiation with electrons

    International Nuclear Information System (INIS)

    Tauber, M.

    1976-01-01

    The disinfection of sewage sludge by irradiation has been discussed very intensively in the last few months. Powerful electron accelerators are now available and the main features of the irradiation of sewage sludge with fast electrons are discussed and the design parameters of such installations described. AEG-Telefunken is building an irradiation plant with a 1.5 MeV, 25 mA electron accelerator, to study the main features of electron irradiation of sewage sludge. (author)

  6. The effect of purified sewage discharge from a sewage treatment plant on the physicochemical state of water in the receiver

    Directory of Open Access Journals (Sweden)

    Kanownik Włodzimierz

    2016-09-01

    Full Text Available The paper presents changes in the contents of physicochemical indices of the Sudół stream water caused by a discharge of purified municipal sewage from a small mechanical-biological treatment plant with throughput of 300 m3·d−1 and a population equivalent (p.e. – 1,250 people. The discharge of purified sewage caused a worsening of the stream water quality. Most of the studied indices values increased in water below the treatment plant. Almost a 100-fold increase in ammonium nitrogen, 17-fold increase in phosphate concentrations and 12-fold raise in BOD5 concentrations were registered. Due to high values of these indices, the water physicochemical state was below good. Statistical analysis revealed a considerable effect of the purified sewage discharge on the stream water physicochemical state. A statistically significant increase in 10 indices values (BOD5, COD-Mn, EC, TDS, Cl−, Na+, K+, PO43−, N-NH4+ and N-NO2 as well as significant decline in the degree of water saturation with oxygen were noted below the sewage treatment plant. On the other hand, no statistically significant differences between the water indices values were registered between the measurement points localised 150 and 1,000 m below the purified sewage discharge. It evidences a slow process of the stream water self-purification caused by an excessive loading with pollutants originating from the purified sewage discharge.

  7. Spatial and Seasonal Variations of Heavy Metal Loads in Uyo Urban Drainage Stream under PS and NPS Pollution

    Directory of Open Access Journals (Sweden)

    O. E. Essien

    2012-12-01

    Full Text Available The concentration of heavy metals (HM in the 4km urban drainage stream in Uyo was studied using grab and composite sampling of water from six stations on the stream, and analyzed by a multipurpose atomic absorption spectrophotometer. The data were statistically analyzed using SPSS version 17 software arid correlated between stations and among samples. HM contamination was evaluated with the coefficient and rate of dispersion between stations and the Normalized Scatter Coefficient (NSC. The seasonal distribution of metal pollution varied individually amongst metals at stations. The Fe and Pb concentrations exceeded the safe drinking water standard, rendering the water quality not acceptable for drinking; however, the quality was within the safe limit for crop production along the river bank. The relative.dominance of heavy metals followed a different sequence in upstream leachate effluent from all downstream stations. The NSC in dry-wet season was higher than in wet season, and was in the order: Fe>Cu>Zn>Pb, showing that large but variable concentration of Fe from PS and NPS contaminated the stream at faster rate in the wet season while Pb contaminated at nearly constant rate. However, in the dry season, Fe and Pb depleted at downstream at rates far higher than Zn as Cu was increasing. Fe and Pb could be good pollution monitor for total maximum daily load (TMDL pollution monitoring programme.

  8. Sewage treatment method

    Science.gov (United States)

    Fassbender, Alex G.

    1995-01-01

    The invention greatly reduces the amount of ammonia in sewage plant effluent. The process of the invention has three main steps. The first step is dewatering without first digesting, thereby producing a first ammonia-containing stream having a low concentration of ammonia, and a second solids-containing stream. The second step is sending the second solids-containing stream through a means for separating the solids from the liquid and producing an aqueous stream containing a high concentration of ammonia. The third step is removal of ammonia from the aqueous stream using a hydrothermal process.

  9. Sewage-pollution indicator bacteria

    Digital Repository Service at National Institute of Oceanography (India)

    Ramaiah, N.; Rodrigues, V.; Alwares, E.; Rodrigues, C.; Baksh, R.; Jayan, S.; Mohandass, C.

    estuaries, Goa, India are described in this chapter. Raw sewage disposal into the Mandovi and Zuari estuaries has been a common practice in the history of the estuaries. With increasing population, the amount of sewage dumped in the estuary has also...

  10. Optimal Planning Method of On-load Capacity Regulating Distribution Transformers in Urban Distribution Networks after Electric Energy Replacement Considering Uncertainties

    Directory of Open Access Journals (Sweden)

    Yu Su

    2018-06-01

    Full Text Available Electric energy replacement is the umbrella term for the use of electric energy to replace oil (e.g., electric automobiles, coal (e.g., electric heating, and gas (e.g., electric cooking appliances, which increases the electrical load peak, causing greater valley/peak differences. On-load capacity regulating distribution transformers have been used to deal with loads with great valley/peak differences, so reasonably replacing conventional distribution transformers with on-load capacity regulating distribution transformers can effectively cope with load changes after electric energy replacement and reduce the no-load losses of distribution transformers. Before planning for on-load capacity regulating distribution transformers, the nodal effective load considering uncertainties within the life cycle after electric energy replacement was obtained by a Monte Carlo method. Then, according to the loss relation between on-load capacity regulating distribution transformers and conventional distribution transformers, three characteristic indexes of annual continuous apparent power curve and replacement criteria for on-load capacity regulating distribution transformers were put forward in this paper, and a set of distribution transformer replaceable points was obtained. Next, based on cost benefit analysis, a planning model of on-load capacity regulating distribution transformers which consists of investment profitability index within the life cycle, investment cost recouping index and capacity regulating cost index was put forward. The branch and bound method was used to solve the planning model within replaceable point set to obtain upgrading and reconstruction scheme of distribution transformers under a certain investment. Finally, planning analysis of on-load capacity regulating distribution transformers was carried out for electric energy replacement points in one urban distribution network under three scenes: certain load, uncertain load and nodal

  11. Redistribution of sewage-nitrogen in estuarine food webs following sewage treatment upgrades

    International Nuclear Information System (INIS)

    Pitt, Kylie A.; Connolly, Rod M.; Maxwell, Paul

    2009-01-01

    Stable nitrogen isotopes were used to assess the effects of wastewater treatment plant (WWTP) upgrades on the utilisation of sewage-N by estuarine biota in Moreton Bay, Australia. We measured δ 15 N of filamentous algae, mangrove leaves and shore crabs at the Brisbane and Logan Rivers before and after scheduled WWTP upgrades, and at two reference rivers where WWTPs had been upgraded >4 years previously. The total N discharged into Brisbane River decreased by >80% after the upgrades had occurred, but N loads remained similar at Logan River despite the upgrade. In Brisbane River, δ 15 N values of algae and crabs decreased and were comparable to the reference rivers within 1-2 years but no changes occurred at Logan River. The δ 15 N of mangrove leaves remained elevated in all rivers, indicating that sewage-N remained a major source to mangroves either from residual WWTP discharges or from N accumulated in the sediments over many years.

  12. Co-digestion of pig slaughterhouse waste with sewage sludge.

    Science.gov (United States)

    Borowski, Sebastian; Kubacki, Przemysław

    2015-06-01

    Slaughterhouse wastes (SHW) are potentially very attractive substrates for biogas production. However, mono-digestion of these wastes creates great technological problems associated with the inhibitory effects of ammonia and fatty acids on methanogens as well as with the foaming in the digesters. In the following study, the co-digestion of slaughterhouse wastes with sewage sludge (SS) was undertaken. Batch and semi-continuous experiments were performed at 35°C with municipal sewage sludge and pig SHW composed of meat tissue, intestines, bristles and post-flotation sludge. In batch assays, meat tissue and intestinal wastes gave the highest methane productions of 976 and 826 dm(3)/kg VS, respectively, whereas the methane yield from the sludge was only 370 dm(3)/kg VS. The co-digestion of sewage sludge with 50% SHW (weight basis) provided the methane yield exceeding 600 dm(3)/kg VS, which was more than twice as high as the methane production from sewage sludge alone. However, when the loading rate exceeded 4 kg VS/m(3) d, a slight inhibition of methanogenesis was observed, without affecting the digester stability. The experiments showed that the co-digestion of sewage sludge with large amount of slaughterhouse wastes is feasible, and the enhanced methane production does not affect the digester stability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Sewage sludge disposal in Austria

    International Nuclear Information System (INIS)

    Koch, F.

    1997-01-01

    Sewage systems serve about 70% of the Austrian population, producing 6 million m 3 of sewage sludge per year with a dry matter content of 4-5%. At present about 52% of this sludge is disposed of in land fills, 33% is incinerated, and only about 15 % is used in agriculture. Although agricultural utilization is becoming increasingly important, several problems, especially those related to public opinion, need to be resolved before increased use will be possible. In this paper, wastewater treatment and sewage-sludge production in Austria, and problems associated with sludge disposal are discussed. (author)

  14. Sewage sludges disinfection

    International Nuclear Information System (INIS)

    Alexandre, D.

    1977-01-01

    There is an hygienic risk in using biological sewage sludges for agriculture. Systematic analysis carried out on sludges samples obtained from purification plants in East and South part of France, show the almost uniform presence of pathogenic microorganisms. Some of it survive more than 9 months after soil application. Conventional process for disinfection: liming and heat are not suitable for agricultural use. On the other hand, irradiation involves no modification in structure and composition of sludges. Radiation doses required for disinfection vary according to microorganisms. If some of them are eliminated with rather light doses (200 krad) mycobacteria, viruses and eggs of worms resist to more important doses. Security dose is estimated around 1000 krad

  15. Sewage sludges disinfection

    International Nuclear Information System (INIS)

    Alexandre, D.; Gevaudan, P.P.

    1977-01-01

    There is a hygienic risk in using biological sewage sludges for agriculture. Systematic analyses carried out on sludge samples obtained from purification plants in the Eastern and Southern part of France, show the almost uniform presence of pathogenic microorganisms. Some of them survive more than nine months after application to the soil. Conventional processes for disinfection, liming and heat, make the sludge unsuitable for agricultural use. On the other hand, irradiation involves no modification of structure and composition of sludges. Radiation doses required for disinfection vary according to the type of microorganism. Some of them are eliminated at rather low doses (200 krad), but mycobacteria, viruses and eggs of worms resist to more important doses. The security dose is estimated to be approx. 1000 krad

  16. Impact of Climate Variability and Landscape Patterns on Water Budget and Nutrient Loads in a Peri-urban Watershed: A Coupled Analysis Using Process-based Hydrological Model and Landscape Indices.

    Science.gov (United States)

    Li, Chongwei; Zhang, Yajuan; Kharel, Gehendra; Zou, Chris B

    2018-06-01

    Nutrient discharge into peri-urban streams and reservoirs constitutes a significant pressure on environmental management, but quantitative assessment of non-point source pollution under climate variability in fast changing peri-urban watersheds is challenging. Soil and Water Assessment Tool (SWAT) was used to simulate water budget and nutrient loads for landscape patterns representing a 30-year progression of urbanization in a peri-urban watershed near Tianjin metropolis, China. A suite of landscape pattern indices was related to nitrogen (N) and phosphorous (P) loads under dry and wet climate using CANOCO redundancy analysis. The calibrated SWAT model was adequate to simulate runoff and nutrient loads for this peri-urban watershed, with Nash-Sutcliffe coefficient (NSE) and coefficient of determination (R 2 ) > 0.70 and percentage bias (PBIAS) between -7 and +18 for calibration and validation periods. With the progression of urbanization, forest remained the main "sink" landscape while cultivated and urban lands remained the main "source" landscapes with the role of orchard and grassland being uncertain and changing with time. Compared to 1984, the landscape use pattern in 2013 increased nutrient discharge by 10%. Nutrient loads modelled under wet climate were 3-4 times higher than that under dry climate for the same landscape pattern. Results indicate that climate change could impose a far greater impact on runoff and nutrient discharge in a peri-urban watershed than landscape pattern change.

  17. Impact of Climate Variability and Landscape Patterns on Water Budget and Nutrient Loads in a Peri-urban Watershed: A Coupled Analysis Using Process-based Hydrological Model and Landscape Indices

    Science.gov (United States)

    Li, Chongwei; Zhang, Yajuan; Kharel, Gehendra; Zou, Chris B.

    2018-06-01

    Nutrient discharge into peri-urban streams and reservoirs constitutes a significant pressure on environmental management, but quantitative assessment of non-point source pollution under climate variability in fast changing peri-urban watersheds is challenging. Soil and Water Assessment Tool (SWAT) was used to simulate water budget and nutrient loads for landscape patterns representing a 30-year progression of urbanization in a peri-urban watershed near Tianjin metropolis, China. A suite of landscape pattern indices was related to nitrogen (N) and phosphorous (P) loads under dry and wet climate using CANOCO redundancy analysis. The calibrated SWAT model was adequate to simulate runoff and nutrient loads for this peri-urban watershed, with Nash-Sutcliffe coefficient (NSE) and coefficient of determination ( R 2) > 0.70 and percentage bias (PBIAS) between -7 and +18 for calibration and validation periods. With the progression of urbanization, forest remained the main "sink" landscape while cultivated and urban lands remained the main "source" landscapes with the role of orchard and grassland being uncertain and changing with time. Compared to 1984, the landscape use pattern in 2013 increased nutrient discharge by 10%. Nutrient loads modelled under wet climate were 3-4 times higher than that under dry climate for the same landscape pattern. Results indicate that climate change could impose a far greater impact on runoff and nutrient discharge in a peri-urban watershed than landscape pattern change.

  18. Optimization of municipal pressure pumping station layout and sewage pipe network design

    Science.gov (United States)

    Tian, Jiandong; Cheng, Jilin; Gong, Yi

    2018-03-01

    Accelerated urbanization places extraordinary demands on sewer networks; thus optimization research to improve the design of these systems has practical significance. In this article, a subsystem nonlinear programming model is developed to optimize pumping station layout and sewage pipe network design. The subsystem model is expanded into a large-scale complex nonlinear programming system model to find the minimum total annual cost of the pumping station and network of all pipe segments. A comparative analysis is conducted using the sewage network in Taizhou City, China, as an example. The proposed method demonstrated that significant cost savings could have been realized if the studied system had been optimized using the techniques described in this article. Therefore, the method has practical value for optimizing urban sewage projects and provides a reference for theoretical research on optimization of urban drainage pumping station layouts.

  19. Essential oil production of lemongrass (Cymbopogon citratus under organic compost containing sewage sludge

    Directory of Open Access Journals (Sweden)

    Júlia V. d'Ávila

    Full Text Available ABSTRACT One of the main urban polluting agents are the sewers, which even with proper treatment end up generating a polluting waste, the sewage sludge. One of the options for the disposal of this sludge is the use in agriculture, due to its high content of organic matter and nutrients. This study aimed to use urban sewage sludge for lemongrass cultivation and essential oil production. The plants were grown in soil containing different organic compost doses (0, 5, 10, 20, 40 and 60 t ha-1, formed from the sewage sludge composting process and waste of urban vegetation pruning. At harvest, plants were analyzed for the concentration of nutrients, chlorophyll content, number of tillers, biomass production, essential oil content and the microbiological quality of the leaves. The results showed that the addition of the compost increased the levels of nutrients in the plants, mainly nitrogen, positively influencing the production of tillers, biomass, chlorophyll contents, yield and essential oil content.

  20. Impact of Battery Energy Storage System Operation Strategy on Power System: An Urban Railway Load Case under a Time-of-Use Tariff

    Directory of Open Access Journals (Sweden)

    Hyeongig Kim

    2017-01-01

    Full Text Available Customer-owned battery energy storage systems (BESS have been used to reduce electricity costs of energy storage owners (ESOs under a time-of-use (TOU tariff in Korea. However, the current TOU tariff can unintentionally induce customer’s electricity usage to have a negative impact on power systems. This paper verifies the impact of different BESS operation strategies on power systems under a TOU tariff by analyzing the TOU tariff structure and the customer’s load pattern. First, several BESS operation strategies of ESO are proposed to reduce the electricity cost. In addition, a degradation cost calculation method for lithium ion batteries is considered for the ESO to determine the optimal BESS operation strategy that maximizes both electricity cost and annual investment cost. The optimal BESS operation strategy that maximizes ESO’s net benefit is illustrated by simulation using an urban railway load data from Namgwangju Station, Korea. The results show that BESS connected to urban railway loads can negative impact power system operation. This is due to the high BESS degradation costs and lack of incentive of differential rates in TOU tariff that can effectively induce proper demand response.

  1. SEWAGE SLUDGE AS AN INGREDIENT IN FERTILIZERS AND SOIL SUBSTITUTES

    Directory of Open Access Journals (Sweden)

    Anna Grobelak

    2016-06-01

    Full Text Available In Poland, sludge management especially in medium and small sewage treatment plants is still a significant problem. According to data from the Central Statistical Office and the report on the implementation of the National Urban Wastewater Treatment Program (in polish KPOŚK land application of sewage sludge remains one of the main methods, although there has been considerable interest known: 'application for other purposes ", where the preparation of composts and fertilizers is included. The use of fertilizer produced from sewage sludge (compost, granules, organic and mineral fertilizers, is regulated by the Act on fertilizers and fertilization, and the relevant implementing rules. For example, they define the test procedure (concerning the quality of fertilizers to enable appropriate permissions to market this type of fertilizers. There is still only several technologies existing on the Polish market dedicated to production of fertilizers in advanced technologies of sewage sludge treatment. Usually the treatment plants are trying to obtain the necessary certificates for generated fertilizers (including composts, or soils substitutes. The advantages of these technologies should be no doubt: the loss of waste status, ability to store the fertilizer and unlimited transportation between areas, sanitization of the product (as a result of the use of calcium or sulfur compounds or temperature should be an alternative for drying technology. While the disadvantages are primarily the investment costs and time consuming certification procedures. However, these solutions enable to maintain the organic matter and phosphorus as well as greater control over possible pollution introduced into the soil.

  2. Effects of urbanization on streamflow, sediment loads, and channel morphology in Pheasant Branch Basin near Middleton, Wisconsin

    Science.gov (United States)

    Krug, W.R.; Goddard, G.L.

    1986-01-01

    A 5-year, data-collection and modeling study was conducted on Pheasant Branch basin in and near Middleton, Wisconsin. The objectives of the study were to: (1) describe the streamflow characteristics, sediment transport, and stream-channel morphology in the Pheasant Branch basin; and (2) relate the above factors to changes caused by urbanization and project the effect of urbanization on the hydrology and channel morphology of the study area.

  3. Integral study of sewage sludges

    International Nuclear Information System (INIS)

    1994-01-01

    Sewage sludges are the by-product generated during the treatment process of waste water, and they are conformed by a solid phase which origin is the accumulation of pollutant materials which has been added to water during natural and anthropogenic activities. Its handling is one of the most serious problems faced by water treatment plants which involve the production, gathering, transportation, re utilization and final disposal of sewage sludges. The main purpose of this project is to perform a technical evaluation of the process of sewage sludge irradiation for its possible application as a choice for treatment and final disposal. Irradiation with gammas from Cobalt-60 shows effectiveness in disinfestation of sewage sludges, since they reduce six times the microbial population with a 7 KGy dose. In like manners with doses of 10 KGy is possible to bring down in 70 % the concentration of organic compounds, as well as to eliminate the presence of 6 to 22 organic compounds on samples of sewage sludges. The whole content of this work is presented in six sections: Introduction, Antecedents, Methodology, Conclusions, Suggestions and Bibliography. (Author)

  4. Radiation sterilization of animal farm sewage

    International Nuclear Information System (INIS)

    Rosiak, J.; Perkowski, J.; Pekala, W.

    1984-01-01

    Influence of irradiation on organisms appearing in farm sewage has been discussed. Practical examples of employing the radiation to sterilization of municipal wastes and liquid sewage from the industrial swine farms have been presented. (author)

  5. Preparation of lightweight concretes with sewage sludge ash and their properties

    International Nuclear Information System (INIS)

    Lee, Hwa Young

    2010-01-01

    Sewage sludge results from the accumulation of solids from the unit processes of chemical coagulation, flocculation and sedimentation during wastewater treatment. Rapid urbanization in many areas of the world has resulted in a drastic increase of sewage sludge. More than two million tons of sewage sludge resulted from the treatment of urban sewage is produced annually in Korea. The majority of sewage sludge is disposed of conventionally by the landfill or ocean disposal method, both of which create severe environmental pollution. However, increasingly stringent environmental regulations and scarcity of landfill sites have posed disposal problems of sludge. Incineration is a viable alternative providing a means of sludge stabilization resulting in a reduced volume of sterile, odorless and practically inert residue. Accordingly, the development of environment friendly treatment technique of SSA (sewage sludge ash) inevitably produced during incineration of sewage sludge may be urgently required. For this aim, an attempt to manufacture the lightweight concrete has been made using sewage sludge ash and the physical properties have been determined in terms of specific gravity, compressive strength and thermal conductivity. As a result, the density of specimen prepared with SSA was ranged from 0.6 to 1.4g/ cm 3 and the compressive strength was ranged from 20 to 40kg/ cm 2 . As far as the thermal conductivity of specimen was concerned, it was ranged from 0.3 to 0.6 W/ mK depending on material composition which was far less than that of concrete. It was concluded that the lightweight concretes prepared with SSA could be applicable to building or construction materials such as insulation board and sound absorption material. (author)

  6. Energy consumption modeling during dairy sewage pretreatment

    Directory of Open Access Journals (Sweden)

    Dąbrowski Wojciech

    2017-01-01

    Full Text Available The research was conducted in a dairy WWTP located in north-eastern Poland with the average flow of 546 m3d-1 and PE 11500 in 2016. Energy consumption was measured with the help of Lumel 3-phase network parameter transducers installed within the plant. The modeling was conducted based on the quantity and quality of raw sewage, after its screening, averaging and dissolved air flotation. The following parameters were determined: BOD5, COD. N-total and P-total. During the research period. 15 measurement series were carried out. Pollution loads removed in primary treatment varied from 167.0 to 803.5 kgO2d-1 and 1205.9 to 10032 kgO2d-1 for BOD5 and COD respectively. The energy consumption share during dairy pretreatment in relation to the total energy consumption was in the range from 13.8 to 28.5% with the mean value of 18.7% during the research period. Energy consumption indicators relating to removed pollution loads for primary treatment were established with the mean values of 0.74 and 0.83 kWhkg-1d-1 for BOD5 and COD respectively. An attempt was made to determine the influence of raw sewage characteristics and pretreatment efficiency on energy consumption of the object. A model of energy consumption during pretreatment was estimated according to the experimental data obtained in the research period. It was modeled using the linear regression model and principal component analysis.

  7. Comprehensive disposal organic sewage by radiation

    International Nuclear Information System (INIS)

    Zheng Zuohuan

    2004-01-01

    With the rapid development of industry, the constituents of sewage have been becoming complicated, and the treating effect of ordinary methods on standard sewage treatment have decreased evidently. Effective application of radiation in the disposal of sewage with some examples is presented, especially the better effect when radiation combined with ordinary methods. (author)

  8. Disinfection of sewage sludge with gamma radiation

    International Nuclear Information System (INIS)

    1980-01-01

    In the Geiselbullach sewage treatment plant near Munich, sewage irradiation by a 60 Co source is being investigated on a technical scale. 145 m 3 of sewage sludge are irradiated per day and then used as field fertilizer. (orig./HBR) [de

  9. 33 CFR 159.85 - Sewage removal.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Sewage removal. 159.85 Section...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.85 Sewage removal. The device must be designed for efficient removal of nearly all of the liquid and solids in the sewage retention...

  10. 33 CFR 159.307 - Untreated sewage.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Untreated sewage. 159.307 Section 159.307 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Operations § 159.307 Untreated sewage. No person shall discharge any untreated sewage from a cruise vessel...

  11. Radioactive contamination of sewage sludge

    International Nuclear Information System (INIS)

    Soeder, C.J.; Zanders, E.; Raphael, T.

    1986-01-01

    Because of the radioactivity released through the explosion of the nuclear reactor near Chernobyl radionuclides have been accumulated to a significant extent in sewage sludge in the Federal Republic of Germany. This is demonstrated for samples from four activated sludge plants according to a recent recommendation of the German Commission for Radiation Protection, there is until now no reason to deviate from the common practices of sludge disposal or incineration. The degree of radioactive contamination of plant materials produced on farm lands on which sewage sludge is being spread cannot be estimated with sufficient certainty yet. Additional information is required. (orig.) [de

  12. Waste management - sewage - special wastes

    International Nuclear Information System (INIS)

    1987-01-01

    The 27 papers represent a cross-section of the subject waste management. Particular attention is paid to the following themes: waste avoidance, waste product utilization, household wastes, dumping technology, sewage sludge treatments, special wastes, seepage from hazardous waste dumps, radioactive wastes, hospital wastes, purification of flue gas from waste combustion plants, flue gas purification and heavy metals, as well as combined sewage sludge and waste product utilization. The examples given relate to plants in Germany and other European countries. 12 papers have been separately recorded in the data base. (DG) [de

  13. Transformation of Silver Nanoparticles in Sewage Sludge during Incineration.

    Science.gov (United States)

    Meier, Christoph; Voegelin, Andreas; Pradas del Real, Ana; Sarret, Geraldine; Mueller, Christoph R; Kaegi, Ralf

    2016-04-05

    Silver nanoparticles (Ag-NP) discharged into the municipal sewer system largely accumulate in the sewage sludge. Incineration and agricultural use are currently the most important strategies for sewage sludge management. Thus, the behavior of Ag-NP during sewage sludge incineration is essential for a comprehensive life cycle analysis and a more complete understanding of the fate of Ag-NP in the (urban) environment. To address the transformation of Ag-NP during sewage sludge incineration, we spiked metallic Ag(0)-NP to a pilot wastewater treatment plant and digested the sludge anaerobically. The sludge was then incinerated on a bench-scale fluidized bed reactor in a series of experiments under variable conditions. Complementary results from X-ray absorption spectroscopy (XAS) and electron microscopy-energy dispersive X-ray (EM-EDX) analysis revealed that Ag(0)-NP transformed into Ag2S-NP during the wastewater treatment, in agreement with previous studies. On the basis of a principal component analysis and subsequent target testing of the XAS spectra, Ag(0) was identified as a major Ag component in the ashes, and Ag2S was clearly absent. The reformation of Ag(0)-NP was confirmed by EM-EDX. The fraction of Ag(0) of the total Ag in the ashes was quantified by linear combination fitting (LCF) of XAS spectra, and values as high as 0.8 were found for sewage sludge incinerated at 800 °C in a synthetic flue gas atmosphere. Low LCF totals (72% to 94%) indicated that at least one relevant reference spectrum was missing in the LCF analysis. The presence of spherical Ag-NP with a diameter of incineration, as demonstrated in this study, needs to be considered in the life cycle assessment of engineered Ag-NP.

  14. Identifying the source, transport path and sinks of sewage derived organic matter

    International Nuclear Information System (INIS)

    Mudge, Stephen M.; Duce, Caroline E.

    2005-01-01

    Since sewage discharges can significantly contribute to the contaminant loadings in coastal areas, it is important to identify sources, pathways and environmental sinks. Sterol and fatty alcohol biomarkers were quantified in source materials, suspended sediments and settling matter from the Ria Formosa Lagoon. Simple ratios between key biomarkers including 5β-coprostanol, cholesterol and epi-coprostanol were able to identify the sewage sources and effected deposition sites. Multivariate methods (PCA) were used to identify co-varying sites. PLS analysis using the sewage discharge as the signature indicated ∼ 25% of the variance in the sites could be predicted by the sewage signature. A new source of sewage derived organic matter was found with a high sewage predictable signature. The suspended sediments had relatively low sewage signatures as the material was diluted with other organic matter from in situ production. From a management viewpoint, PLS provides a useful tool in identifying the pathways and accumulation sites for such contaminants. - Multivariate statistical analysis was used to identify pathways and accumulation sites for contaminants in coastal waters

  15. Diazinon and chlorpyrifos loads in precipitation and urban and agricultural storm runoff during January and February 2001 in the San Joaquin River basin, California

    Science.gov (United States)

    Zamora, Celia; Kratzer, Charles R.; Majewski, Michael S.; Knifong, Donna L.

    2003-01-01

    The application of diazinon and chlorpyrifos on dormant orchards in 2001 in the San Joaquin River Basin was 24 percent less and 3.2 times more than applications in 2000, respectively. A total of 16 sites were sampled during January and February 2001 storm events: 7 river sites, 8 precipitation sites, and 1 urban storm drain. The seven river sites were sampled weekly during nonstorm periods and more frequently during storm runoff from a total of four storms. The monitoring of storm runoff at a city storm drain in Modesto, California, occurred simultaneously with the collection of precipitation samples from eight sites during a January 2001 storm event. The highest concentrations of diazinon occurred during the storm periods for all 16 sites, and the highest concentrations of chlorpyrifos occurred during weekly nonstorm sampling for the river sites and during the January storm period for the urban storm drain and precipitation sites. A total of 60 samples (41 from river sites, 10 from precipitation sites, and 9 from the storm drain site) had diazinon concentrations greater than 0.08 ?g/L, the concentration being considered by the California Department of Fish and Game as its criterion maximum concentration for the protection of aquatic habitats. A total of 18 samples (2 from river sites, 9 from precipitation sites, and 7 from the storm drain site) exceeded the equivalent California Department of Fish and Game guideline of 0.02 ?g/L for chlorpyrifos. The total diazinon load in the San Joaquin River near Vernalis during January and February 2001 was 23.8 pounds active ingredient; of this amount, 16.9 pounds active ingredient were transported by four storms, 1.06 pounds active ingredient were transported by nonstorm events, and 5.82 pounds active ingredient were considered to be baseline loads. The total chlorpyrifos load in the San Joaquin River near Vernalis during January and February 2001 was 2.17 pounds active ingredient; of this amount, 0.702 pound active

  16. Incorporation of cigarette butts into nests reduces nest ectoparasite load in urban birds: new ingredients for an old recipe?

    Science.gov (United States)

    Suárez-Rodríguez, Monserrat; López-Rull, Isabel; Garcia, Constantino Macías

    2013-02-23

    Birds are known to respond to nest-dwelling parasites by altering behaviours. Some bird species, for example, bring fresh plants to the nest, which contain volatile compounds that repel parasites. There is evidence that some birds living in cities incorporate cigarette butts into their nests, but the effect (if any) of this behaviour remains unclear. Butts from smoked cigarettes retain substantial amounts of nicotine and other compounds that may also act as arthropod repellents. We provide the first evidence that smoked cigarette butts may function as a parasite repellent in urban bird nests. The amount of cellulose acetate from butts in nests of two widely distributed urban birds was negatively associated with the number of nest-dwelling parasites. Moreover, when parasites were attracted to heat traps containing smoked or non-smoked cigarette butts, fewer parasites reached the former, presumably due to the presence of nicotine. Because urbanization changes the abundance and type of resources upon which birds depend, including nesting materials and plants involved in self-medication, our results are consistent with the view that urbanization imposes new challenges on birds that are dealt with using adaptations evolved elsewhere.

  17. Effectiveness of DTPA Chelate on Cd Availability in Soils Treated with Sewage Sludge

    Directory of Open Access Journals (Sweden)

    Pegah Houshyar

    2017-09-01

    Full Text Available Application of sewage sludge as a fertilizer on farmlands is a common practice in most countries. Although the practice may play a positive role in plant performance, the organic amendments introduced may increase the soil heavy metals content. This study was conducted in Arak, Iran, to investigate the effectiveness of DTPA chelate on corn Cd availability in a sewage sludge treated soil. The treatments consisted of sewage sludge (0, 15, and 30 t ha-1 polluted with cadmium applied at 0, 5, 10, and 15 mg kg-1 as well as DTPA applied at 0 and 1.5 mmol kg-1 soil. Corn plants were then grown in the soil in each treatmnent and, on day 60, the physic-chemical characteristics and Cd quantities were measured ion both the corn plants and soil samples. Application of 1.5 m mol of DTPA chelate in soil contaminated with 5 mg Cd led to a significant increase in the soil available Cd content. It was also observed that application of DTPA chelate to soils containing 30 t ha-1 of sewage sludge polluted with 10 mg Cd increased root and shoot Cd concentrations by 17 and 25%, respectively. Results indicated the effectiveness of DTPA chelate in reducing Cd phytoremediation with increasing sewage sludge loading rate. This was evidenced by the lowest phytoremediation effectiveness observed for the treatment with the greatest sewage sludge loading (30 t ha-1 and the lowest cadmium pollution (5 mg Cd.

  18. Process for sewage biological treatment from uranium

    International Nuclear Information System (INIS)

    Popa, K.; Cecal, A.; Craciun, I.

    2004-01-01

    The invention relates to the sewage treatment, in particular to the sewage biological treatmen from radioactive waste, namely from uranium. The process dor sewage biological treatment from uranium includes cultivation in the sewage of the aquatic plants Lemna minor and Spirulina platensis. The plants cultivation is carried out in two stages. In the first stage for cultivation is used Lemna minor in the second stage - Spirulina platensis . After finishing the plant cultivation it is carried out separation of their biomass. The result of the invention consists in increasing the uranyl ions by the biomass of plants cultivated in the sewage

  19. Process for sewage biological treatment from uranium

    International Nuclear Information System (INIS)

    Popa, Karin; Cecal, Alexandru; Craciun, Iftimie Ionel; Rudic, Valeriu; Gulea, Aurelian; Cepoi, Liliana

    2004-01-01

    The invention relates to the sewage treatment, in particular to the sewage biological treatment from radioactive waste, namely from uranium. The process for sewage biological treatment from uranium includes cultivation in the sewage of the aquatic plants Lemna minor and Spirulina platensis. The plant cultivation is carried out in two stages. In the first stage for cultivation is used Lemna minor and in the second stage - Spirulina platensis. After finishing the plant cultivation it is carried out separation of their biomass. The result of the invention consists in increasing the uranyl ions accumulation by the biomass of plants cultivated in the sewage.

  20. Sewage sterilization through gamma radiation

    International Nuclear Information System (INIS)

    Vieira, D.V.; Teixeira, W.M.S.; Silva, F.C.A. da

    2017-01-01

    Lack of sewage treatment and adequate sanitation conditions can contribute to the proliferation of numerous parasitic and infectious diseases in addition to water degradation. Approximately fifty types of infections can be transmitted from a sick to a healthy person through different pathways involving human excreta. Untreated sewage can contaminate water, food, hands, soil, etc. Epidemics of certain diseases such as typhoid, cholera, dysenteries, etc., and countless cases of worms are responsible for high mortality rates in third world countries. In the work the different techniques of sewage treatment by disinfestation and sterilization were analyzed, highlighting the use and the advantages of the gamma radiation as well as the aspects of the radiological protection involved. The technique of sewage sterilization using gamma radiation is a method of controlling bacteria and microorganisms. It is estimated that more than 200 large irradiators are in operation worldwide, of which 5 are in Brazil, for general sterilization use. These facilities use a large amount of radioactive material, in the order of millions of Becquerel, for sterilization with high doses of radiation, which can generate lethal doses in a few minutes. These industrial facilities use Cobalt-60, being classified by the International Atomic Energy Agency - IAEA as Category 1 of high risk, and must possess a high level of radiological protection to carry out the sterilization, standing out the defense in depth. Specific legislation on radiological protection should be drafted for safe work and avoid future radiation accidents

  1. Fast pyrolysis of lignin, macroalgae and sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    Trinh, N.T.

    2013-04-15

    macronutrients as N, P, K, S, Mg and Ca and this could make the chars most valuable as raw materials for fertilizer production. The sewage sludge waste bulk volume (the char compared to the sludge) was reduced with 52 % by pyrolysis at 575 deg. C. It is seen that the fast pyrolysis process provides a promising method to reduce cost for landfilling and produce a bio-oil that can be used as a fuel. The pyrolysis temperature has a considerable effect on the product distributions of the lignin and sewage sludge PCR pyrolysis, as well as their bio-oil properties with respect to molecular mass distribution, identified GC-MS component compositions, water-insoluble fraction, viscosity, and HHV. A maximum of organic oil yields of lignin and sewage sludge PCR pyrolysis were obtained at optimal temperatures of 550 - 575 deg. C. In this work, the behaviors of slurry samples of wood, char and grinded char with respect to phase transitions, rheological properties, elemental composition, and energy density were investigated. Also pumping properties were investigated at temperatures of 25, 40 and 60 deg. C and the solids loading of 0 - 20 wt%. The bioslurries obtained a volume energy density of 21-23 GJ/m{sup 3} and an energy densification factor of 4.5 - 5 (when compared to beech wood). Their apparent viscosities were significantly influenced by the solid loading levels (0 - 20 wt %) and temperatures (25 - 60 deg. C). The slurry samples with 10 wt% char (having d80 of 276 {mu}m) and 20 wt% grinded char (having d80 of 118 {mu}m) were successfully pumped into a pressurized chamber (0 - 6 bar). (LN)

  2. Using nitrogen stable isotope ratios (δ15N) of macroalgae to determine the effectiveness of sewage upgrades: changes in the extent of sewage plumes over four years in Moreton Bay, Australia

    International Nuclear Information System (INIS)

    Costanzo, Simon D.; Udy, James; Longstaff, Ben; Jones, Adrian

    2005-01-01

    Nitrogen loading to aquatic ecosystems from sewage is recognised worldwide as a growing problem. The use of nitrogen stable isotopes as a means of discerning sewage nitrogen in the environment has been used annually by the Ecosystem Health Monitoring Program in Moreton Bay (Australia) since 1997 when the technique was first developed. This ('sewage plume mapping') technique, which measures the δ 15 N isotopic signature of the red macroalga Catenella nipae after incubation in situ, has demonstrated a large reduction in the magnitude and spatial extent of sewage nitrogen within Moreton Bay over the past 5 years. This observed reduction coincides with considerable upgrades to the nitrogen removal efficacy at several sewage treatment plants within the region. This paper describes the observed changes and evaluates whether they can be attributed to the treatment upgrades

  3. Using nitrogen stable isotope ratios ({delta}{sup 15}N) of macroalgae to determine the effectiveness of sewage upgrades: changes in the extent of sewage plumes over four years in Moreton Bay, Australia

    Energy Technology Data Exchange (ETDEWEB)

    Costanzo, Simon D. [National Research Centre for Environmental Toxicology, University of Queensland, 39 Kessels Road, Coopers Plains, QLD 4108 (Australia)]. E-mail: s.costanzo@uq.edu.au; Udy, James [Marine Botany, Centre for Marine Studies, University of Queensland, 4072 (Australia); Longstaff, Ben [Environmental Protection Agency, 80 Meiers Road, Indooroopilly, QLD 4058 (Australia); Jones, Adrian [University of Maryland Center for Environmental Science, P.O. Box 775, Cambridge, MD 21613, USA (United States)

    2005-07-01

    Nitrogen loading to aquatic ecosystems from sewage is recognised worldwide as a growing problem. The use of nitrogen stable isotopes as a means of discerning sewage nitrogen in the environment has been used annually by the Ecosystem Health Monitoring Program in Moreton Bay (Australia) since 1997 when the technique was first developed. This ('sewage plume mapping') technique, which measures the {delta}{sup 15}N isotopic signature of the red macroalga Catenella nipae after incubation in situ, has demonstrated a large reduction in the magnitude and spatial extent of sewage nitrogen within Moreton Bay over the past 5 years. This observed reduction coincides with considerable upgrades to the nitrogen removal efficacy at several sewage treatment plants within the region. This paper describes the observed changes and evaluates whether they can be attributed to the treatment upgrades.

  4. Environmental Groundwater Vulnerability Assessment in Urban Water Mines (Porto, NW Portugal

    Directory of Open Access Journals (Sweden)

    Maria José Afonso

    2016-11-01

    Full Text Available A multidisciplinary approach was developed to estimate urban groundwater vulnerability to contamination combining hydrogeology, hydrogeochemistry, subterranean hydrogeotechnics, groundwater ecotoxicology and isotope tracers. Paranhos and Salgueiros spring waters in Porto City were used as a case study. Historical and current vulnerability scenarios were compared using hydrogeological GIS-based modelling. Potential contamination sources were mapped around the spring galleries. Most of these were point sources and their potential contamination load was moderate. The ecotoxicological assessment indicated a low acute toxicity potential. Groundwater radionuclides appeared to be mainly controlled by geological factors and biomineralisation. Vulnerability maps suggest that most of the area has a moderate to low vulnerability to contamination. However, some surface sources such as sewage systems cause contamination and contribute to increased vulnerability. This integrated approach was demonstrated to be adequate for a better knowledge of urban hydrogeological processes and their dynamics, and highlighted the importance of a vulnerability assessment in urban areas.

  5. Effects of cumulative trauma load on perceptions of health, blood pressure, and resting heart rate in urban African American youth.

    Science.gov (United States)

    Conner-Warren, Rhonda

    2014-04-01

    This study examined relationships between cumulative trauma (CT) and urban African American (AA) adolescents' blood pressure (BP), heart rate (HR), and perceptions of health. A correlational design using secondary data analysis studied effects of CT, health outcomes, and perceptions of health. Participants were 175 urban AA youth (11-16 years) who completed structured surveys and physiological measures of HR and BP before and after exercise. AA youth were experiencing high levels of CT. Negative correlations were obtained between AA females' perceptions of their health and systolic BP with levels of trauma. No gender differences were found in HR or BP. AA females with high CT may perceive themselves as less healthy and can be at risk for health problems. © 2014, Wiley Periodicals, Inc.

  6. Heavy metals availability and soil fertility after land application of sewage sludge on dystroferric Red Latosol

    Directory of Open Access Journals (Sweden)

    Rodrigo Santos Moreira

    2013-12-01

    Full Text Available Sewage sludge is the solid residue obtained from urban sewage treatment plants. It is possible to use the sludge in a sustainable way as fertilizer and as soil conditioner due to its high levels of organic matter and nutrients. Besides pathogens and volatile organic compounds, the residue may also contain heavy metals which may accumulate and contaminate crops and the food chain. The aim of this study was evaluates the changes in the fertility of dystrophic Red Latosol and in the availability of heavy metals following application of sewage sludge. It was assessed whether organic matter supplied to the soil as large amounts of sewage sludge would decrease availability of heavy metals in the soil due to of insoluble compounds formation. From this, an experiment was carried out in polyethylene pots using lettuce plant for test. Sewage sludge were applied to the soil in concentrations equivalent to 60, 120 and 180 t ha-1, and a control without sludge, in four replicates, in a completely randomized design. The results show that sewage sludge led to an increase of organic matter contents, of the cation exchange capacity (CEC and of nutrients found in the soil. It also improved plant growth up to a concentration of 120 t ha-1. Availability of heavy metals, however, was reduced in sludge concentrations starting with 120 t ha-1.

  7. The contribution of pharmaceutically active compounds from healthcare facilities to a receiving sewage treatment plant in Canada.

    Science.gov (United States)

    Kleywegt, Sonya; Pileggi, Vince; Lam, Yuet Ming; Elises, Alan; Puddicomb, Aaron; Purba, Gurminder; Di Caro, Joanne; Fletcher, Tim

    2016-04-01

    Concentrations and percent loadings of pharmaceutically active compounds (PhACs) and other emerging contaminants released from healthcare facilities (2 hospitals and a long-term care facility) to a sewage treatment plant (STP) in a large urban sewershed were evaluated. An additional hospital outside the sewershed was also monitored. Fourteen of the 24 steroids/hormones and 88 of the 117 PhACs and emerging contaminants were detected at least once. Commonly used substances, including cotinine, caffeine and its metabolite 1,7-dimethylxanthine, ibuprofen and naproxen (analgesics), venlafaxine (antidepressant), and N,N-diethyl-meta-toluamide (insect repellant), were detected in all samples at all sites. Concentrations detected in the large specialty hospital outside the sewershed were similar to those within the sewershed. Cytotoxic drugs (tamoxifen and cyclophosphamide) and x-ray contrast media (iopamidol and diatrizoic acid) were infrequently detected in hospital effluents. Analysis for antibiotics indicated that azithromycin, clarithromycin, ciprofloxacin, erythromycin, ofloxacin, and sulfamethoxazole were consistently detected in hospital wastewaters, as was triclosan (antibacterial agent). Fifteen compounds individually contributed greater than 1% to the total PhAC and emerging contaminant load to the STP from the 2 hospitals in the sewershed, and 9 compounds in the STP effluent exceeded ecotoxicological criteria. The present survey demonstrates that point source discharges from healthcare facilities in this sewershed make a small contribution to the overall PhAC and emerging contaminant loading compared with the total concentrations entering the receiving STP. © 2015 SETAC.

  8. Fast pyrolysis of lignin, macroalgae and sewage sludge

    DEFF Research Database (Denmark)

    Trinh, Ngoc Trung

    effect on the product distributions of the lignin and sewage sludge PCR pyrolysis, as well as their bio-oil properties with respect to molecular mass distribution, identified GC-MS component compositions, water-insoluble fraction, viscosity, and HHV. A maximum of organic oil yields of lignin and sewage...... samples of wood, char and grinded char with respect to phase transitions, rheological properties, elemental composition, and energy density were investigated. Also pumping properties were investigated at temperatures of 25, 40 and 60 ºC and the solids loading of 0 - 20 wt%. The bioslurries obtained...... of the condenser nozzle and high rotor speed for obtaining high bio-oil. The recognized limitations lead to that the old PCR set-up cannot be safely scaled up and perform well in a continuous mode. Thus a new set-up with significant modifications of reactor and bio-condenser has been manufactured to overcome...

  9. Detection and genotyping of group A rotaviruses isolated from sewage samples in Monastir, Tunisia between April 2007 and April 2010.

    Science.gov (United States)

    Hassine-Zaafrane, M; Kaplon, J; Ben Salem, I; Sdiri-Loulizi, K; Sakly, N; Pothier, P; Aouni, M; Ambert-Balay, K

    2015-11-01

    To ascertain the viral load, the distribution of G and P types of group A rotaviruses (RV-A) in sewage samples and to compare strains in clinical, animal and environmental samples. During our study from April 2007 to April 2010, 518 samples of raw and treated sewage were collected from two biological sewage treatment plants (STPs) located in the Monastir region, Tunisia. RV-A was detected by real-time RT-PCR in 375 (72·4%) sewage samples. According to the quantification results of RV-A, it appears that the viral load in raw and treated sewage of the two STPs was quite similar (P = 0·735). The genotyping of RV-A strains detected in sewage samples showed a great diversity with 10 G types and 8 P types. Most of them were described as common in humans, but we also detected genotypes commonly found in animals. All the genotypes detected in two previous studies performed in our laboratory on clinical and bovine samples were also found in environmental samples. However, some genotypes commonly found in animal were only found in sewage samples. The comparison of environmental, clinical and animal data suggests that STPs may convey not only human sewage but also animal wastes, both of them contaminated with numerous RV-A strains which are not efficiently eliminated by the sewage treatment process and may spread to surface waters. This work demonstrates the potential release of human and animal RV-A into water sources, representing a public health risk, by inducing gastroenteritis in population, but also by increasing the risk of zoonotic transmission and formation of reassortant viruses which could get a higher infectious potential. Our findings also suggest that monitoring of sewage may provide an additional tool to determine the epidemiology of RV-A circulating in a given community. © 2015 The Society for Applied Microbiology.

  10. Effects of urban wastewater on crab and mollusc assemblages in equatorial and subtropical mangroves of East Africa

    Science.gov (United States)

    Cannicci, Stefano; Bartolini, Fabrizio; Dahdouh-Guebas, Farid; Fratini, Sara; Litulo, Carlos; Macia, Adriano; Mrabu, Elisha J.; Penha-Lopes, Gil; Paula, José

    2009-09-01

    Mangrove forests are known to accomplish crucial ecosystem functions and services. They are nursery areas for fish, prawns and crabs, which provide coastal communities with a variety of food, timber and chemicals, and protect coasts from catastrophic events, such as tsunamis. Recently, a novel ecological service has been proposed for mangrove systems, namely natural wastewater treatment wetlands. This hypothesis was based on experimental data collected mainly in Chinese mangrove systems, which proved that mangrove soils were efficient in absorbing nutrients. Moreover, sewage loading seemed harmless to both plants and benthic communities in these systems. However, before promoting the use of natural mangroves as pollution buffers, or constructed mangrove wetlands as sewage treatment facilities, more data are needed on their overall tolerance to organic loading. Differences in macrobenthos patterns were thus investigated between peri-urban mangroves and sites not affected by sewage disposal in East Africa. We assessed differences in epifaunal assemblages, comprising crabs and molluscs, employing multivariate ACI unbalanced analyses to compare peri-urban mangrove swamps with those characteristic of non-urban mangroves with similar ecological traits. The sampling design was spatially nested, replicates being assessed at equatorial (southern Kenya) and subtropical (southern Mozambique) sites. The results manifested a consistent increase in crab biomass at the peri-urban sites in both Kenya and Mozambique. Moreover, the peri-urban systems were richer than the non-urban mangroves, both in terms of fiddler crabs ( Uca spp.) which feed on benthic microalgae and bacteria, and sesarmids, such as Perisesarma guttatum and Neosarmatium meinerti, which feed on both substratum and leaf litter. The abundance of gastropods, in contrast, decreased significantly, especially in Kenya, mainly due to the disappearance of the mud whelk Terebralia palustris. The results thus indicate that

  11. The importance of excretion by Chironomus larvae on the internal loads of nitrogen and phosphorus in a small eutrophic urban reservoir

    Directory of Open Access Journals (Sweden)

    R. Henry

    Full Text Available Measurements of ammonium and phosphate excretion by the Chironomus larvae were conducted in order to evaluate the importance of these chironomids for the internal loads of a small eutrophic urban reservoir. Ammonium and phosphate excretion rates by Chironomus larvae of small size (6-10 mm total length were significantly higher than those of the Chironomids having medium (9-11 mm and large (11-16 mm sizes. A dependence in relation to temperature was recorded for the ammonium and phosphate excretions that was significantly higher at 25 °C than at 20 and 15 °C. Through a linear relation between biomass (dry weight and total length and, between excretion and biomass and, data on chironomids densities, after an intense sampling in 33 sites distributed all along the reservoir bottom, the mean phosphate and ammonium excretion rates corresponded to 2,014 ± 5,134 µg.m-2/day and 1,643 ± 3,974 µg.m-2/day, respectively. Considering the mean biomass (34 mg.m-2 of Chironomus, the lake area (88,156 m² and the mean excretion rates, the contribution of benthic chironomids to the internal loads would be 181 KgP and 147 KgN. for the sampling months (October-November 1998. These values showed that the internal loads by excretion from Chironomus larvae correspond to approximately 33% of the external loads of phosphorus in the lake and, in the case of nitrogen, to only 5%.

  12. Cold Vacuum Drying facility sanitary sewage collection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) sanitary sewage collection system. The sanitary sewage collection system provides collection and storage of effluents and raw sewage from the CVDF to support the cold vacuum drying process. This system is comprised of a sanitary sewage holding tank and pipes for collection and transport of effluents to the sanitary sewage holding tank

  13. Non-Point Source Pollutant Load Variation in Rapid Urbanization Areas by Remote Sensing, Gis and the L-THIA Model: A Case in Bao'an District, Shenzhen, China

    Science.gov (United States)

    Li, Tianhong; Bai, Fengjiao; Han, Peng; Zhang, Yuanyan

    2016-11-01

    Urban sprawl is a major driving force that alters local and regional hydrology and increases non-point source pollution. Using the Bao'an District in Shenzhen, China, a typical rapid urbanization area, as the study area and land-use change maps from 1988 to 2014 that were obtained by remote sensing, the contributions of different land-use types to NPS pollutant production were assessed with a localized long-term hydrologic impact assessment (L-THIA) model. The results show that the non-point source pollution load changed significantly both in terms of magnitude and spatial distribution. The loads of chemical oxygen demand, total suspended substances, total nitrogen and total phosphorus were affected by the interactions between event mean concentration and the magnitude of changes in land-use acreages and the spatial distribution. From 1988 to 2014, the loads of chemical oxygen demand, suspended substances and total phosphorus showed clearly increasing trends with rates of 132.48 %, 32.52 % and 38.76 %, respectively, while the load of total nitrogen decreased by 71.52 %. The immigrant population ratio was selected as an indicator to represent the level of rapid urbanization and industrialization in the study area, and a comparison analysis of the indicator with the four non-point source loads demonstrated that the chemical oxygen demand, total phosphorus and total nitrogen loads are linearly related to the immigrant population ratio. The results provide useful information for environmental improvement and city management in the study area.

  14. Composting of sewage sludge irradiated

    International Nuclear Information System (INIS)

    Hashimoto, Shoji; Watanabe, Hiromasa; Nishimura, Koichi; Kawakami, Waichiro

    1981-01-01

    Recently, the development of the techniques to return sewage sludge to forests and farm lands has been actively made, but it is necessary to assure its hygienic condition lest the sludge is contaminated by pathogenic bacteria. The research to treat sewage sludge by irradiation and utilize it as fertilizer or soil-improving material has been carried out from early on in Europe and America. The effects of the irradiation of sludge are sterilization, to kill parasites and their eggs, the inactivation of weed seeds and the improvement of dehydration. In Japan, agriculture is carried out in the vicinity of cities, therefore it is not realistic to use irradiated sludge for farm lands as it is. The composting treatment of sludge by aerobic fermentation is noticed to eliminate the harms when the sludge is returned to forests and farm lands. It is desirable to treat sludge as quickly as possible from the standpoint of sewage treatment, accordingly, the speed of composting is a problem. The isothermal fermentation experiment on irradiated sludge was carried out using a small-scale fermentation tank and strictly controlling fermentation conditions, and the effects of various factors on the fermentation speed were studied. The experimental setup and method are described. The speed of composting reached the maximum at 50 deg C and at neutral or weak alkaline pH. The speed increased with the increase of irradiation dose up to 30 Mrad. (Kako, I.)

  15. Let a sewage plant running smart

    Science.gov (United States)

    Yang, Shan-Shan; Pang, Ji-Wei; Jin, Xiao-Man; Wu, Zhong-Yang; Yang, Xiao-Yin; Guo, Wan-Qian; Zhao, Zhi-Qing; Ren, Nan-Qi

    2018-03-01

    Out-dated technical equipment, occlusive information communication, inadequate sanitation, low management level and some irrational distribution structures in the existing sewage plants bring about lower sewage treatment efficiency and poorer water quality, thereby permanently harming human health and severely damaging the environment. With the rapid development of scientific-technological progress and the vigorous support of the entire international community, the existing sewage plants call for more and more intelligent operation and management in the future. This review for the first time proposes the novel concept of the “smart” sewage plant, and gives a through interpretation of its special functions and attributes. We envision that the future smart sewage plant will became an “ambient intelligence” in all aspects in the sewage plants.

  16. Urbanization, housing and environmental quality indicators ...

    African Journals Online (AJOL)

    Urbanization, housing and environmental quality indicators. ... Journal of Agriculture, Forestry and the Social Sciences ... Urbanization ideally should also imply an enhancement of housing quality and other components of human settlements such as power supply, portable water, good roads, proper refuse and sewage ...

  17. A proposal to improve e-waste collection efficiency in urban mining: Container loading and vehicle routing problems - A case study of Poland.

    Science.gov (United States)

    Nowakowski, Piotr

    2017-02-01

    Waste electrical and electronic equipment (WEEE), also known as e-waste, is one of the most important waste streams with high recycling potential. Materials used in these products are valuable, but some of them are hazardous. The urban mining approach attempts to recycle as many materials as possible, so efficiency in collection is vital. There are two main methods used to collect WEEE: stationary and mobile, each with different variants. The responsibility of WEEE organizations and waste collection companies is to assure all resources required for these activities - bins, containers, collection vehicles and staff - are available, taking into account cost minimization. Therefore, it is necessary to correctly determine the capacity of containers and number of collection vehicles for an area where WEEE need to be collected. There are two main problems encountered in collection, storage and transportation of WEEE: container loading problems and vehicle routing problems. In this study, an adaptation of these two models for packing and collecting WEEE is proposed, along with a practical implementation plan designed to be useful for collection companies' guidelines for container loading and route optimization. The solutions are presented in the case studies of real-world conditions for WEEE collection companies in Poland. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Research on Performance and Microstructure of Sewage Pipe Mortar Strengthened with Different Anti-Corrosion Technologies

    Science.gov (United States)

    Mu, Song; Zhou, Huaxin; Shi, Liang; Liu, Jianzhong; Cai, Jingshun; Wang, Feng

    2017-10-01

    Mostly urban underground sewage is the acidic corrosion environment with a high concentration of aggressive ions and microbe, which resulted in performance deterioration and service-life decrease of sewage concrete pipe. In order to effectively protect durability of the concrete pipe, the present paper briefly analysed the main degradation mechanism of concrete pipe attacked by urban underground sewage, and proposed that using penetrating and strengthening surface sealer based on inorganic chemistry. In addition, using index of compressive strength, weight loss and appearance level to investigate the influence of the sealer on corrosion resistance of mortar samples after different dry-wet cycles. Besides, comparative research on effect of the sealer, aluminate cement and admixture of corrosion resistance was also addressed. At last, the SEM technology was used to reveal the improvement mechanism of different technologies of corrosion resistance. The results indicated that the sealer and aluminate cement can significantly improve corrosion resistance of mortar. Besides, the improvement effect can be described as the descending order: the penetrating and strengthening surface sealer > aluminate cement > admixture of corrosion resistance. The mortar sample treated with the sealer displayed the condensed and sound microstructure which proved that the sealer can improve the corrosion resistance to urban underground sewage.

  19. Identification of sewage leaks by active remote-sensing methods

    Science.gov (United States)

    Goldshleger, Naftaly; Basson, Uri

    2016-04-01

    The increasing length of sewage pipelines, and concomitant risk of leaks due to urban and industrial growth and development is exposing the surrounding land to contamination risk and environmental harm. It is therefore important to locate such leaks in a timely manner, to minimize the damage. Advances in active remote sensing Ground Penetrating Radar (GPR) and Frequency Domain Electromagnetic (FDEM) technologies was used to identify leaking potentially responsible for pollution and to identify minor spills before they cause widespread damage. This study focused on the development of these electromagnetic methods to replace conventional acoustic methods for the identification of leaks along sewage pipes. Electromagnetic methods provide an additional advantage in that they allow mapping of the fluid-transport system in the subsurface. Leak-detection systems using GPR and FDEM are not limited to large amounts of water, but enable detecting leaks of tens of liters per hour, because they can locate increases in environmental moisture content of only a few percentage along the pipes. The importance and uniqueness of this research lies in the development of practical tools to provide a snapshot and monitoring of the spatial changes in soil moisture content up to depths of about 3-4 m, in open and paved areas, at relatively low cost, in real time or close to real time. Spatial measurements performed using GPR and FDEM systems allow monitoring many tens of thousands of measurement points per hectare, thus providing a picture of the spatial situation along pipelines and the surrounding. The main purpose of this study was to develop a method for detecting sewage leaks using the above-proposed geophysical methods, since their contaminants can severely affect public health. We focused on identifying, locating and characterizing such leaks in sewage pipes in residential and industrial areas.

  20. Multi-Criteria Sustainability Assessment of Urban Sludge Treatment Technologies

    DEFF Research Database (Denmark)

    An, Da; Xi, Beidou; Ren, Jingzheng

    2017-01-01

    to determine the weights of the criteria for sustainability assessment, and extension theory was used to prioritize the alternative technologies for the treatment of urban sewage sludge and grade their sustainability performances. An illustrative case including three technologies (compositing, incineration...

  1. Where to dispose of the sewage sludge?

    International Nuclear Information System (INIS)

    Beurer, P.; Geering, F.

    2001-01-01

    The 'proper' course for the disposal of sewage sludge is a topic that has continually sparked intense discussion for years. New legal regulations have developed which have significantly changed the disposal structure. Nevertheless, the consumer market of agriculture products has an increasing influence on sewage sludge recycling possibilities. In this report, the changes in sewage sludge disposal within the last ten years and the expected development is pointed out. On account of legal guidelines and of political market influences, the thermal recycling of sewage sludge is considered as the future solution, which should, however, be adapted according to marginal situations. (author)

  2. Dewatering properties of differently treated sewage sludge

    International Nuclear Information System (INIS)

    Zehnder, H.J.

    1977-01-01

    A study on dewatering properties of radiosterilized sewage sludge of different type and origin was carried out. For comparison, also heat-treated (pasteurized) sludge was investigated. The specific filtration resistance of irradiated sewage sludge was lowered in all types of sludge examined. In general, pasteurization increased this parameter. The settling properties of irradiated digested sewage sludge was slightly improved, mainly in the first hours after treatment. Microbial effects may mask the real sedimentation relations especcially in aerobically stabilized sludges. A pasteurization treatment of sewage sludge caused an increased content of soluble substances and suspended particles in the supernatant water. The supernatant water from irradiated sludge showed a smaller increase

  3. Distribution, fate and risk assessment of antibiotics in sewage treatment plants in Hong Kong, South China.

    Science.gov (United States)

    Leung, H W; Minh, T B; Murphy, M B; Lam, James C W; So, M K; Martin, Michael; Lam, Paul K S; Richardson, B J

    2012-07-01

    Occurrence, removal, consumption and environmental risks of sixteen antibiotics were investigated in several sewage treatment plants (STPs) featuring different treatment levels in Hong Kong, China. Cefalexin, ofloxacin and erythromycin-H(2)O were predominant with concentrations of 1020-5640, 142-7900 and 243-4740 ng/L in influent, respectively; their mass loads were comparable to levels reported in urban regions in China and were at the high end of the range reported for western countries. The target antibiotics behaved differently depending on the treatment level employed at the STPs and relatively higher removal efficiencies (>70%) were observed for cefalexin, cefotaxime, amoxicillin, sulfamethoxazole and chloramphenicol during secondary treatment. ß-lactams were especially susceptible to removal via the activated sludge process while macrolides were recalcitrant (antibiotic consumption in Hong Kong was back-calculated based on influent mass flows and compared with available prescription and usage data. This model was verified by a good approximation of 82% and 141% to the predicted consumption of total ofloxacin, but a less accurate estimate was obtained for erythromycin usage. Risk assessment indicated that algae are susceptible to the environmental concentrations of amoxicillin as well as the mixture of the nine detected antibiotics in receiving surface waters. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. SewageLCI 1.0 - A first generation inventory model for quantification of chemical emissions via sewage systems. Application on chemicals of concern

    DEFF Research Database (Denmark)

    Gallice, Aurélie; Birkved, Morten; Kech, Sébastien

    obtained applying SewageLCI 1.0 model reveal that it’s possible to account for many of the variations in emission quantities of chemicals, caused by variations in the chemical fate properties and in the composition of national waste water treatment grids. The results indicate that the total emission...... treatment is emission to surface water recipients, other environmental compartments such as agricultural soil may receive considerable loads of chemicals emitted by the national specific waste water grids. The SewageLCI 1.0 presentation and case study reveal how broad inclusion of chemicals emitted......Lack of inventory data on chemical emissions often forces life cycle assessors to rely on crude emissions estimates (e.g. 100 % of the applied chemical mass is assumed emitted) or in the worst case to omit chemical emissions due to lack of emission data. The inventory model SewageLCI 1.0, provides...

  5. Stabilization/solidification of sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    Boura, Panagiota; Katsioti, Margarita; Tsakiridis, Petros; Katsiri, Alexandra

    2003-07-01

    The main objective of this work is to investigate a viable alternative for the final disposal of sewage sludge from urban wastewater treatment plants by its use as an additive in developing new construction materials. For this purpose, several mixtures of sludge- cement and sludge-cement and jarosite/alunite precipitate were prepared. Jarosite/alunite precipitate is a waste product of a new hydrometallurgical process. Two kinds of sludge were used: primary sludge from Psyttalia Wastewater Treatment Plant, which receives a considerable amount of industrial waste, and biological sludge from Metamorphosi Wastewater Treatment Plant. Various percentages of these sludges were stabilized/solidified with Portland cement and Portland cement with jarosite/alunite. The specimens were tested by determination of compressive strength according to the methods described by European Standard EN 196. X-Ray Diffraction (XRD) analysis as well as Thermogravimetry-Differential Thermal Analysis (TG-DTA) were used to determine the hydration products in 28 days. Furthermore, Toxicity Characteristic Leaching Procedure test for heavy metals (TCLP), were carried out in order to investigate the environmental compatibility of these new materials. (author)

  6. Treatment and re-use of urban sewage by means of aerated submerged biological filters and tertiary treatment; Depuracion y reutilizacion de las aguas residuales urbanas mediante filtros biologicos sumergidos aireados con tratamiento terciario

    Energy Technology Data Exchange (ETDEWEB)

    Mujal, F. J.

    2000-07-01

    The installations required for treating and re-using urban waste waters are reviewed. The treatment system put forward is called AERATED SURMERGED BIOLOGICAL FILTER AQUA PROCESS (S.B.F.). In this system, once that water has been clarified, it is treated biologically in an aerated reactor containing porous ceramic balls. After this it is filtered with silica+anthracite as a tertiary treatment. This technique minimize energy consumption and achieve optimum treatment performance at low running costs, as it requires little maintenance. Once the waste water has been treated in this way, the effluent is suitable for re-use to irrigate crops or infiltrate into underground aquifers. (Author)

  7. Urban Waste Grease Resource Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Wiltsee, G.

    1999-03-17

    This study collected and analyzed data on urban waste grease resources in 30 randomly selected metropolitan areas in the United States. Two major categories (yellow grease feedstock collected from restaurants by rendering companies; and grease trap wastes from restaurants, which can either be pumped into tank trucks for disposal or flow through municipal sewage systems into wastewater treatment plants) were considered in this study.

  8. SMART MANAGEMENT OF THE WATER URBAN CYCLE

    OpenAIRE

    Sánchez Zaplana, Antonio

    2014-01-01

    Aguas Municipalizadas de Alicante, AMAEM, is the company in charge of managing the urban water cycle in Alicante and several neighbour towns: San Vicente, Sant Joan, Petrer, Monforte and El Campello. More specifically, AMAEM provides the water distribution service in all of them, and is responsible for the sewage service in Alicante, Sant Joan and Monforte. The population served amounts to 750,000 inhabitants, supplied by a 2,000 km water distribution network and 700 km of sewage drains. AMAE...

  9. Volatile fatty acids production from sewage organic matter by combined bioflocculation and anaerobic fermentation

    NARCIS (Netherlands)

    Khiewwijit, R.; Keesman, K.J.; Rijnaarts, H.H.M.; Temmink, B.G.

    2014-01-01

    This work aims at exploring the feasibility of a combined process bioflocculation to concentrate sewage organic matter and anaerobic fermentation to produce volatile fatty acids (VFA). Bioflocculation, using a high-loaded aerobic membrane bioreactor (HL-MBR), was operated at an HRT of 1 h and an SRT

  10. Effect of linear alkylbenzene mixtures and sanitary sewage in biochemical and molecular responses in pacific oyster Crassostrea gigas.

    Science.gov (United States)

    Flores-Nunes, Fabrício; Mattos, Jacó J; Zacchi, Flávia L; Serrano, Miguel A S; Piazza, Clei E; Sasaki, Silvio T; Taniguchi, Satie; Bicego, Márcia C; Melo, Cláudio M R; Bainy, Afonso C D

    2015-11-01

    Urban effluents are rich in nutrients, organic matter, pharmaceuticals and personal care products (PPCPs), pesticides, hydrocarbons, surfactants, and others. Previous studies have shown that oysters Crassostrea gigas accumulate significant levels of linear alkylbenzenes (LABs) in sanitary sewage contaminated sites, but there is little information about its toxicological effects in marine bivalves. The aim of this study was to analyze the transcription of genes in two tissues of C. gigas exposed for 12, 24, and 36 h to LABs or sanitary sewage. Likewise, the activity of antioxidant and biotransformation enzymes was measured in oysters exposed for 36 h in all groups. Oysters exposed to LABs and oysters exposed to sanitary sewage showed different patterns of transcriptional responses. LAB-exposed oysters showed lower level of biological responses than the oysters exposed to sanitary sewage. Despite the ability of the oyster C. gigas to accumulate LABs (28-fold), the data indicate that these contaminants are not the cause for the transcriptional responses observed in oysters exposed to sanitary sewage. Possibly, the biological changes observed in the sanitary sewage-exposed oysters are associated with the presence of other contaminants, which might have caused synergistic, additive, or antagonistic effects. The results show that FABP-like and GST-ω-like messenger RNAs (mRNAs) have a rapid response in tissues of oyster C. gigas exposed to sanitary sewage, suggesting a possible protective response and a role in maintaining homeostasis of these organisms.

  11. Sewage Disposal in Port Harcourt, Nigeria.

    Science.gov (United States)

    Ayotamuno, M. J.

    1993-01-01

    This survey of the Port Harcourt, Nigeria, sewage disposal system exemplifies sewage disposal in the developing world. Results reveal that some well-constructed and maintained drains, as well as many open drains and septic tanks, expose women and children to the possibility of direct contact with parasitic organisms and threaten water resources.…

  12. Survey of radiation effect on sewage sludge

    International Nuclear Information System (INIS)

    M'selmi, Nadia Ammar

    2005-01-01

    The high nutrient and organic matter contents of sewage sludge make it a useful soil amandment for famers. the presence of heavy metals and pathogens poses a major problem for utilisation of sladge to agriculture land. Radiation is a convenable method of sewage treatment. (author)

  13. Storm Sewage Dilution in Smaller Streams

    DEFF Research Database (Denmark)

    Larsen, Torben; Vestergaard, Kristian

    1987-01-01

    A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow.......A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow....

  14. Contamination profiles and mass loadings of macrolide antibiotics and illicit drugs from a small urban wastewater treatment plant.

    Science.gov (United States)

    Loganathan, Bommanna; Phillips, Malia; Mowery, Holly; Jones-Lepp, Tammy L

    2009-03-01

    Information is limited regarding sources, distribution, environmental behavior, and fate of prescribed and illicit drugs. Wastewater treatment plant (WWTP) effluents can be one of the sources of pharmaceutical and personal care products (PPCP) into streams, rivers and lakes. The objective of this study was to determine the contamination profiles and mass loadings of urobilin (a chemical marker of human waste), macrolide antibiotics (azithromycin, clarithromycin, roxithromycin), and two drugs of abuse (methamphetamine and ecstasy), from a small (antibiotics analyzed, azithromycin was consistently detected in influent and effluent samples. In general, influent samples contained relatively higher concentrations of the analytes than the effluents. Based on the daily flow rates and an average concentration of 17.5 ng L(-1) in the effluent, the estimated discharge of azithromycin was 200 mg day(-1) (range 63-400 mg day(-1)). Removal efficiency of the detected analytes from this WWTP were in the following order: urobilin>methamphetamine>azithromycin with percentages of removal of 99.9%, 54.5% and 47%, respectively, indicating that the azithromycin and methamphetamine are relatively more recalcitrant than others and have potential for entering receiving waters.

  15. Faecal coliform simulation on sewage discharge for an environmentally sustainable township in Medini Iskandar Johor Malaysia

    Science.gov (United States)

    Teh, Su Yean; Koh, Hock Lye; Lee, Elizabeth; Woo, Wing Thye; Tan, Wai Kiat

    2017-11-01

    The Medini Iskandar Development is a 2300-acre multi-purpose urban development comprising residential, commercial, educational, business and recreational areas. The developer applied to the Department of Environment (DOE) Johor in July 2008 for approval of the environmental impact assessment (EIA) report for the overall Medini development. A conditional approval of the EIA report was granted by the DOE subject to some conditions, one of which stipulated that sewage effluent from the centralized sewage treatment plant (STP) is not permitted to be discharged into Sungai Pendas. A suitable location for the discharge of sewage into the Selat Johor is to be identified, based on a hydraulic and water quality modelling investigation. This modelling investigation aims to assess the impact of the discharge of treated sewage effluent on the marine water quality and on aquatic life in the Selat Johor. The supplementary EIA report was submitted to the DOE. Approval was granted in December 2011 for the construction of the marine sewage outfall and its operations. This paper presents the sampling and simulation results for key hydraulic and environmental parameters suitable for sustaining acceptable faecal coliform criteria in Selat Johor. Simulation models used include WASP7 developed by USEPA and AQUASEA developed by Vatnaskil Consulting Engineers.

  16. EFFECTS OF EXCESS URBAN RUNOFF ON WASTE WATER FLOW IN PÉCS, HUNGARY

    Directory of Open Access Journals (Sweden)

    L. RONCZYK

    2012-12-01

    Full Text Available Global warming has been leading to climate change that is predicted to cause an increase in the frequency and intensity of rainfall. Urban areas must be designed to cope with the undesired effect and risks associated with stormwater runoff. Stormwater, entering into the sewerage of Pécs, SW Hungary, exerts an extra load on wastewater and sewage transfer in the underground pipeline system. Based on precipitation and pumping station flow data, we identified a strong correspondence between rainfall and flow behavior in Pécs. We also determined the types of foreign waters entering the sewerage according to their source and origin. Our study also indicates that 32% of the entire land area has a low-degree infrastructure for cutting-edge stormwater drainage and management. The results of the current research aid to evaluate the adequate methodology for risk analysis of each sewage catchment. The spatial analysis of waste water system and its physical and human geographical environment became an effective tool to help the local waterworks (Tettye Forrásház Ltd. to estimate potential hazard level in each sewage catchment and allocate and distribute pumping costs and efforts among the pumping stations during spatiallyheterogeneous torrential rainfall events.

  17. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013)

    Science.gov (United States)

    Lara-Santillán, Pedro M.; Mendoza-Villena, Montserrat; Fernández-Jiménez, L. Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008–2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period. PMID:24895677

  18. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013

    Directory of Open Access Journals (Sweden)

    Pedro M. Lara-Santillán

    2014-01-01

    Full Text Available This paper presents a comparative study of the electricity consumption (EC in an urban low-voltage substation before and during the economic crisis (2008–2013. This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012 with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis. These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.. The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period.

  19. Sewage sludge pasteurization by gamma radiation: financial viability case studies

    International Nuclear Information System (INIS)

    Swinwood, J.F.; Kotler, J.

    1990-01-01

    This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1. Small volume sewage treatment plant experiencing high sludge disposal costs; 2. Large volume sewage treatment plant experiencing low sludge disposal costs; 3. Large volume sewage treatment plant experiencing high sludge disposal costs. (author)

  20. Sewage sludge pasteurization by gamma radiation: financial viability case studies

    Energy Technology Data Exchange (ETDEWEB)

    Swinwood, J.F.; Kotler, J. (Nordion International Inc., Kanata, Ontario (Canada))

    1990-01-01

    This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1. Small volume sewage treatment plant experiencing high sludge disposal costs; 2. Large volume sewage treatment plant experiencing low sludge disposal costs; 3. Large volume sewage treatment plant experiencing high sludge disposal costs. (author).

  1. 40 CFR 35.925-13 - Sewage collection system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Sewage collection system. 35.925-13... Sewage collection system. That, if the project involves sewage collection system work, such work (a) is... existing or planned capacity to adequately treat such collected sewage. Replacement or major rehabilitation...

  2. Sewage sludge pasteurization by gamma radiation: Financial viability case studies

    Science.gov (United States)

    Swinwood, Jean F.; Kotler, Jiri

    This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1) Small volume sewage treatment plant experiencing high sludge disposal costs. 2) Large volume sewage treatment plant experiencing low sludge disposal costs. 3) Large volume sewage treatment plant experiencing high sludge disposal costs.

  3. Pressurized Fluidized Bed Combustion of Sewage Sludge

    Science.gov (United States)

    Suzuki, Yoshizo; Nojima, Tomoyuki; Kakuta, Akihiko; Moritomi, Hiroshi

    A conceptual design of an energy recovering system from sewage sludge was proposed. This system consists of a pressurized fluidized bed combustor, a gas turbine, and a heat exchanger for preheating of combustion air. Thermal efficiency was estimated roughly as 10-25%. In order to know the combustion characteristics of the sewage sludge under the elevated pressure condition, combustion tests of the dry and wet sewage sludge were carried out by using laboratory scale pressurized fluidized bed combustors. Combustibility of the sewage sludge was good enough and almost complete combustion was achieved in the combustion of the actual wet sludge. CO emission and NOx emission were marvelously low especially during the combustion of wet sewage sludge regardless of high volatile and nitrogen content of the sewage sludge. However, nitrous oxide (N2O) emission was very high. Hence, almost all nitrogen oxides were emitted as the form of N2O. From these combustion tests, we judged combustion of the sewage sludge with the pressurized fluidized bed combustor is suitable, and the conceptual design of the power generation system is available.

  4. Land application of sewage sludge: Pathogen issues

    International Nuclear Information System (INIS)

    Chang, A.C.

    1997-01-01

    Diseases transmitted via the faecal-oral exposure route cause severe gastroenteric disorders, and large numbers of causative organisms are discharged with the faecal matter of infected individuals. For this reason, pathogenic bacteria, viruses, protozoa, or helminths, are always found in sewage sludge. If not properly treated for use in agriculture, sludge can be a source of pathogenic contamination. Radiation is an attractive method to reduce the numbers of microorganisms in sewage sludge. Routine examination for pathogens is not practised nor recommended because complicated and costly procedures are involved. Instead, an indicator organism is usually assayed and enumerated. In this paper, methods are discussed for the investigation of pathogens in sewage sludge. (author)

  5. Optimization of monitoring sewage with radionuclide contaminants

    International Nuclear Information System (INIS)

    Egorov, V.N.

    1991-01-01

    Recommendations on optimization of monitoring contaminated sewage aimed at enviromental protection agxinst radioactive contamination at minimum cost are presented. The way of selecting water sampling technique depends on water composition stability and flow rate. Depending on the type of radionuclide distribution in the sewage one can estimate minimum frequency of sampling or number of samples sufficient for assuring reliability of the conclusion on the excess or non-excess of permissible radioactive contamination levels, as well as analysis assigned accuracy. By irregular contaminated sewage-discharge and possibility of short-term releases of different form and duration, sampling should be accomplished through automatic devices of continuons or periodic operation

  6. REEMISSION OF MERCURY COMPOUNDS FROM SEWAGE SLUDGE DISPOSAL

    OpenAIRE

    Beata Janowska

    2016-01-01

    The sewage sludge disposal and cultivation methods consist in storage, agricultural use, compost production, biogas production or heat treatment. The sewage sludge production in municipal sewage sludge treatment plants in year 2013 in Poland amounted to 540.3 thousand Mg d.m. The sewage sludge for agricultural or natural use must satisfy chemical, sanitary and environmental safety requirements. The heavy metal content, including the mercury content, determines the sewage sludge disposal metho...

  7. Linking river nutrient concentrations to land use and rainfall in a paddy agriculture-urban area gradient watershed in southeast China.

    Science.gov (United States)

    Xia, Yongqiu; Ti, Chaopu; She, Dongli; Yan, Xiaoyuan

    2016-10-01

    The effects of land use and land-use changes on river nutrient concentrations are not well understood, especially in the watersheds of developing countries that have a mixed land use of rice paddy fields and developing urban surfaces. Here, we present a three-year study of a paddy agricultural-urban area gradient watershed in southeast China. The annual anthropogenic nitrogen (N) input from the agricultural region to the urban region was high, yet the results showed that the monthly nutrient concentrations in the river were low in the rainy seasons. The nutrient concentrations decreased continuously as the river water passed through the traditional agriculture region (TAR; paddy rice and wheat rotation) and increased substantially in the city region (CR). The traditional agricultural reference region exported most of the nutrient loads at high flows (>1mmd(-1)), the intensified agricultural region (IAR, aquaculture and poultry farming) exported most of the nutrient loads at moderate flows (between 0.5 and 1mmd(-1)), and the CR reference area exported most of the nutrient loads under low to moderate flows. We developed a statistical model to link variations in the nutrient concentrations to the proportion of land-use types and rainfall. The statistical results showed that impervious surfaces, which we interpret as a proxy for urban activities including sewage disposal, were the most important drivers of nutrient concentrations, whereas water surfaces accounted for a substantial proportion of the nutrient sinks. Therefore, to efficiently reduce water pollution, sewage from urban areas must be addressed as a priority, although wetland restoration could also achieve substantial pollutant removal. Copyright © 2016. Published by Elsevier B.V.

  8. Dynamics of pollution-indicator and heterotrophic bacteria in sewage treatment lagoons.

    OpenAIRE

    Legendre, P; Baleux, B; Troussellier, M

    1984-01-01

    The spatio-temporal dynamics of pollution-indicator bacteria and aerobic heterotrophic bacteria were studied in the sewage treatment lagoons of an urban wastewater center after 26 months of biweekly sampling at eight stations in these lagoons. Robust statistical methods of time-series analysis were used to study successional steps (through chronological clustering) and rhythmic behavior through time (through contingency periodogram). The aerobic heterotrophic bacterial community showed two ty...

  9. VT Data - Onsite Sewage Disposal Soil Ratings

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) ONSITE is a pre-selected subset of SSURGO certified soil data depicting onsite sewage disposal ratings of Vermont soils. The NRCS Top20 table was...

  10. Toxic effects of domestic sewage on zooplankton

    Digital Repository Service at National Institute of Oceanography (India)

    Gajbhiye, S.N.; Nair, V.R.; Desai, B.N.

    that they are very sensitive to the sewage. Copepods, Lucifer and decapod larvae (20-30% concentration.) were moderately tolerant. Acetes, medusae, ctenophores and mysids were the most resistant groups (42-49% concentration)....

  11. phytoremediation of sewage sludge in soils contaminated

    African Journals Online (AJOL)

    PROF EKWUEME

    repeated increase daily or weekly application of sewage ... fertilizers, herbicides, germicides and decomposition and burning of fossil fuels. ... However, organic and inorganic pollutants greatly ... green vegetables for the in-situ or ex-situ.

  12. Agricultural yields of irradiated sewage sludge

    International Nuclear Information System (INIS)

    Magnavacca, Cecilia; Miranda, E.; Sanchez, M.

    1999-01-01

    Lettuce, radish and ryegrass have been used to study the nitrogen fertilization of soil by sewage sludge. The results show that the irradiated sludge improve by 15 - 30 % the production yield, compared to the non-irradiated sludge. (author)

  13. grown on soil amended with sewage sludge

    African Journals Online (AJOL)

    DELL

    2Department of Civil Engineering, Federal University of Agriculture, Abeokuta, Ogun State, Nigeria. Corresponding ... Key Words: Sewage sludge, Green amaranth, Phytoextraction, Heavy metals. ..... Wastewater-irrigated Areas of Titagarh,.

  14. Sewage reflects the microbiomes of human populations.

    Science.gov (United States)

    Newton, Ryan J; McLellan, Sandra L; Dila, Deborah K; Vineis, Joseph H; Morrison, Hilary G; Eren, A Murat; Sogin, Mitchell L

    2015-02-24

    Molecular characterizations of the gut microbiome from individual human stool samples have identified community patterns that correlate with age, disease, diet, and other human characteristics, but resources for marker gene studies that consider microbiome trends among human populations scale with the number of individuals sampled from each population. As an alternative strategy for sampling populations, we examined whether sewage accurately reflects the microbial community of a mixture of stool samples. We used oligotyping of high-throughput 16S rRNA gene sequence data to compare the bacterial distribution in a stool data set to a sewage influent data set from 71 U.S. cities. On average, only 15% of sewage sample sequence reads were attributed to human fecal origin, but sewage recaptured most (97%) human fecal oligotypes. The most common oligotypes in stool matched the most common and abundant in sewage. After informatically separating sequences of human fecal origin, sewage samples exhibited ~3× greater diversity than stool samples. Comparisons among municipal sewage communities revealed the ubiquitous and abundant occurrence of 27 human fecal oligotypes, representing an apparent core set of organisms in U.S. populations. The fecal community variability among U.S. populations was significantly lower than among individuals. It clustered into three primary community structures distinguished by oligotypes from either: Bacteroidaceae, Prevotellaceae, or Lachnospiraceae/Ruminococcaceae. These distribution patterns reflected human population variation and predicted whether samples represented lean or obese populations with 81 to 89% accuracy. Our findings demonstrate that sewage represents the fecal microbial community of human populations and captures population-level traits of the human microbiome. The gut microbiota serves important functions in healthy humans. Numerous projects aim to define a healthy gut microbiome and its association with health states. However

  15. Urban stormwater - greywater management system for sustainable urban water management at sub-watershed level

    Science.gov (United States)

    Singh Arora, Amarpreet

    2017-11-01

    Urban water management involves urban water supply (import, treatment and distribution of water), urban wastewater management (collection, treatment and disposal of urban sewage) and urban storm water management. Declining groundwater tables, polluted and declining sources of water, water scarcity in urban areas, unsatisfactory urban water supply and sanitation situation, pollution of receiving water bodies (including the ground water), and urban floods have become the concerns and issues of sustainable urban water management. This paper proposes a model for urban stormwater and sewage management which addresses these concerns and issues of sustainable urban water management. This model proposes segregation of the sewage into black water and greywater, and urban sub-watershed level stormwater-greywater management systems. During dry weather this system will be handling only the greywater and making the latter available as reclaimed water for reuse in place of the fresh water supply. During wet weather, the system will be taking care of (collection and treatment) both the storm water and the greywater, and the excess of the treated water will be disposed off through groundwater recharging. Application of this model in the Patiala city, Punjab, INDIA for selected urban sub-watersheds has been tried. Information and background data required for the conceptualization and design of the sub-watershed level urban stormwater-greywater management system was collected and the system has been designed for one of the sub-watersheds in the Patiala city. In this paper, the model for sustainable urban water management and the design of the Sub-watershed level Urban Stormwater-Greywater Management System are described.

  16. Sewage Reflects the Microbiomes of Human Populations

    Science.gov (United States)

    Newton, Ryan J.; McLellan, Sandra L.; Dila, Deborah K.; Vineis, Joseph H.; Morrison, Hilary G.; Eren, A. Murat

    2015-01-01

    ABSTRACT Molecular characterizations of the gut microbiome from individual human stool samples have identified community patterns that correlate with age, disease, diet, and other human characteristics, but resources for marker gene studies that consider microbiome trends among human populations scale with the number of individuals sampled from each population. As an alternative strategy for sampling populations, we examined whether sewage accurately reflects the microbial community of a mixture of stool samples. We used oligotyping of high-throughput 16S rRNA gene sequence data to compare the bacterial distribution in a stool data set to a sewage influent data set from 71 U.S. cities. On average, only 15% of sewage sample sequence reads were attributed to human fecal origin, but sewage recaptured most (97%) human fecal oligotypes. The most common oligotypes in stool matched the most common and abundant in sewage. After informatically separating sequences of human fecal origin, sewage samples exhibited ~3× greater diversity than stool samples. Comparisons among municipal sewage communities revealed the ubiquitous and abundant occurrence of 27 human fecal oligotypes, representing an apparent core set of organisms in U.S. populations. The fecal community variability among U.S. populations was significantly lower than among individuals. It clustered into three primary community structures distinguished by oligotypes from either: Bacteroidaceae, Prevotellaceae, or Lachnospiraceae/Ruminococcaceae. These distribution patterns reflected human population variation and predicted whether samples represented lean or obese populations with 81 to 89% accuracy. Our findings demonstrate that sewage represents the fecal microbial community of human populations and captures population-level traits of the human microbiome. PMID:25714718

  17. Global nitrogen and phosphate in urban wastewater for the period 1970 to 2050

    NARCIS (Netherlands)

    Drecht, van G.; Bouwman, A.F.; Harrison, J.; Knoop, J.M.

    2009-01-01

    This paper presents estimates for global N and P emissions from sewage for the period 1970-2050 for the four Millennium Ecosystem Assessment scenarios. Using country-specific projections for population and economic growth, urbanization, development of sewage systems, and wastewater treatment

  18. Tracking persistent pharmaceutical residues from municipal sewage to drinking water

    Science.gov (United States)

    Heberer, Thomas

    2002-09-01

    In urban areas such as Berlin (Germany) with high municipal sewage water discharges and low surface water flows there is a potential risk of drinking water contamination by polar organic compounds when groundwater recharge is used in drinking water production. Thus, some pharmaceutically active compounds (PhACs) are not eliminated completely in the municipal sewage treatment plants (STPs) and they are discharged as contaminants into the receiving waters. In terms of several monitoring studies carried out in Berlin between 1996 and 2000, PhACs such as clofibric acid, diclofenac, ibuprofen, propyphenazone, primidone and carbamazepine were detected at individual concentrations up to the μg/l-level in influent and effluent samples from STPs and in all surface water samples collected downstream from the STPs. Under recharge conditions, several compounds were also found at individual concentrations up to 7.3 μg/l in samples collected from groundwater aquifers near to contaminated water courses. A few of the PhACs were also identified at the ng/l-level in Berlin tap water samples.

  19. A 1-Year Quantitative Survey of Noro-, Adeno-, Human Boca-, and Hepatitis E Viruses in Raw and Secondarily Treated Sewage from Two Plants in Norway.

    Science.gov (United States)

    Myrmel, M; Lange, H; Rimstad, E

    2015-09-01

    A study of enteric viruses in raw and treated sewage from two secondary treatment plants, which received sewage from Oslo city (plant A) and small municipalities in Hedmark county in Norway (plant B), showed high levels of noro-, adeno-, and bocavirus throughout the year. A seasonal variation was observed for adeno- and GII norovirus with higher levels during winter and bocavirus that had more positive samples during winter. The virus concentrations in raw sewage were comparable in the two plants, with medians (log10 genome copies per liter) of 6.1, 6.3, 6.0, and 4.5 for noro GI, noro GII, adeno-, and bocavirus, respectively. The level of hepatitis E virus was not determined as it was below the limit of quantification. The mean log10 virus reduction was 0.55 (plant A) and 1.44 (plant B) with the highest reduction found in the plant with longer hydraulic retention time. The adenoviruses were dominantly serotype 41, while serotype 12 appeared sporadically. Of the 102 raw and treated sewage samples that were tested, eight were positive for hepatitis E virus of which four were from treated sewage. Two of the four obtained gene sequences from hepatitis E virus originated from the rural sewage samples and showed high similarity with a genotype 3 strain of hepatitis E virus detected in local piglets. Two other hepatitis E virus sequences obtained from urban sewage samples showed high similarities with genotype 3 strains isolated from urban sewage in Spain and a human genotype 1 isolate from India. The study gives information on the levels of noroviruses in raw and treated sewage, which is valuable to risk assessment, information indicating that some infections with hepatitis E viruses in Norway have a regional origin and that human bocavirus 2 and 3 are prevalent in the Norwegian population.

  20. Sustainability of Domestic Sewage Sludge Disposal

    Directory of Open Access Journals (Sweden)

    Claudia Bruna Rizzardini

    2014-04-01

    Full Text Available Activated sludge is now one of the most widely used biological processes for the treatment of wastewaters from medium to large populations. It produces high amounts of sewage sludge that can be managed and perceived in two main ways: as a waste it is discharged in landfill, as a fertilizer it is disposed in agriculture with direct application to soil or subjected to anaerobic digestion and composting. Other solutions, such as incineration or production of concrete, bricks and asphalt play a secondary role in terms of their degree of diffusion. The agronomical value of domestic sewage sludge is a proved question, which may be hidden by the presence of several pollutants such as heavy metals, organic compounds and pathogens. In this way, the sustainability of sewage sludge agricultural disposal requires a value judgment based on knowledge and evaluation of the level of pollution of both sewage sludge and soil. The article analyzed a typical Italian case study, a water management system of small communities, applying the criteria of evaluation of the last official document of European Union about sewage sludge land application, the “Working Document on Sludge (3rd draft, 2000”. The report brought out good sewage sludge from small wastewater treatment plants and soils quality suggesting a sustainable application.

  1. Urban Transport and Communication

    International Nuclear Information System (INIS)

    Irandu, E.M.

    1999-01-01

    The population according to the 1989 census was 21,448,774 inhabitants. This figure shows that on average the total population has been increasing by more than 40% every decade since 1948. As a result the widening gap between fertility and mortality, the population is growing at an accelerated rate. The current official population growth rate figure of 3.4% per annum puts the country among the world's most rapidly growing nations. It is projected that by the year 2010, the population will be about 37.4 million. At present the urban centres with a population size of 2,000 people and above constitute about 18.1% of the total population (Kenya, 1994). Rapid economic growth has led to the development of a number of urban centres as centres of commerce, industry and tourism. Consequently, this has led to rural urban drift. This drift to urban areas causes a number of problems which if unresolved will limit the ability of the urban centres to support their population The rapid increase in urban population causes a shortage of facilities to meet the increasing demand in services such as public transport, water supply, sewage and housing (Ramatullah, 1997: 161-168). Urban Transport acts as catalyst to both urban and national development, by facilitating the movements associated with urban and national Development. They provide a means by which goods and services are made available to industry and consumers, creating opportunity for social and economic interaction and employment. Without urban transport, access to health, education and employment would not be possible. Indeed urban transport is what gives life to urban development

  2. Indicating anthropogenic effectson urban water system - indicators and extension

    Science.gov (United States)

    Strauch, G.; Ufz-Team

    2003-04-01

    Urban water systems are polluted by diffusive and direct contribution of anthropogenic activities. Besides industrial contaminants like aromatic and chlorinated HC and other persistent organic compounds, the urban aquatic environment is increasingly polluted by low concentrated but high eco-toxic compounds as pharmaceuticals, fragrances, plasticizers which most have disrupt endocrine functions, and trace elements carried in by surface and sub-surface waste water and seeping processes. This contamination could have a longtime impact on the urban ecosystem and on the human health. The interdisciplinary project on risk assessment of water pollution was initiated to explore new methodologies for assessing human activities on the urban water system and processes among urban watersheds. In a first assumption we used a flow model concept with in- and output and surface water transport represented by the city of Halle, Germany, and the river Saale. The river Saale acts as surface water system collecting waste water inputs along the city traverse. We investigated the anthropogenic effect on the urban water system using the indicators hydrological parameters, compound specific pattern of complex organic substances and trace elements, isotopic signatures of water (H, O) and dissolved substances (sulfate, DIC, nitrate), pathogens, and microbiota. A first balance modeling showed that main ions are not very sensitive concerning the direct urban input into the river. Depending on the discharge of the river in high and low flood stages the load of dissolved matter has no specific urban effect. However, the concentration pattern of fragrances (tonalid, galaxolid) and endocrine disrupters (t-nonylphenol) point to a different pollution along the city traverse: downstream of the sewage plant a higher load was observed in comparison to the upstream passage. Furthermore, a degradation ability of fungi and bacteria occurred in the bank sediments could be detected in lab experiments

  3. Urban Evolution: The Role of Water

    Directory of Open Access Journals (Sweden)

    Sujay S. Kaushal

    2015-07-01

    Full Text Available The structure, function, and services of urban ecosystems evolve over time scales from seconds to centuries as Earth’s population grows, infrastructure ages, and sociopolitical values alter them. In order to systematically study changes over time, the concept of “urban evolution” was proposed. It allows urban planning, management, and restoration to move beyond reactive management to predictive management based on past observations of consistent patterns. Here, we define and review a glossary of core concepts for studying urban evolution, which includes the mechanisms of urban selective pressure and urban adaptation. Urban selective pressure is an environmental or societal driver contributing to urban adaptation. Urban adaptation is the sequential process by which an urban structure, function, or services becomes more fitted to its changing environment or human choices. The role of water is vital to driving urban evolution as demonstrated by historical changes in drainage, sewage flows, hydrologic pulses, and long-term chemistry. In the current paper, we show how hydrologic traits evolve across successive generations of urban ecosystems via shifts in selective pressures and adaptations over time. We explore multiple empirical examples including evolving: (1 urban drainage from stream burial to stormwater management; (2 sewage flows and water quality in response to wastewater treatment; (3 amplification of hydrologic pulses due to the interaction between urbanization and climate variability; and (4 salinization and alkalinization of fresh water due to human inputs and accelerated weathering. Finally, we propose a new conceptual model for the evolution of urban waters from the Industrial Revolution to the present day based on empirical trends and historical information. Ultimately, we propose that water itself is a critical driver of urban evolution that forces urban adaptation, which transforms the structure, function, and services of urban

  4. Chemical investigation of sewage effluents of Hyderabad city

    International Nuclear Information System (INIS)

    Laghari, A.; Chandio, S.N.; Khushawar, M.Y.; Laghari, M.Y.

    2000-01-01

    Water samples of sewage effluents were collected from sewage collection points located at Latifabad units 9-11, Husainabad and Qasimabad sewage pumping stations. The sewage is pumped towards Southern Sewage treatment plant (SSTP) or is used for agricultural purposes. The water samples from SSTP were also collected and analyzed for pH, conducively, salinity, alkalinity, chlorides, hardness, total, volatile and fixed residues, dissolved oxygen, chemical oxygen demand, nitrogen and phosphorous contents. Variation in the results between sewage water and effluents were noted. (author)

  5. The Territorial Dimension of Sewage Networks: the Case of Recreio dos Bandeirantes, Rio de Janeiro, Brazil.

    Science.gov (United States)

    Mendes, Thiago Monteiro; Barcellos, Christovam

    2018-02-01

    The urban suburbs of Brazilian cities have grown without an adequate sanitation infrastructure. Different social groups try to overcome these shortcomings seeking local sanitation alternatives at individual or community levels, contrasting with the universal model of sewage networks. This study was developed in the suburban neighborhood of Recreio dos Bandeirantes, Rio de Janeiro, Brazil, in order to analyze the installation process of the sewage system under a territorial approach. Data facilitated the construction of territorial schemes related to conflicts during the implementation of sewage networks in this neighborhood, where middle class groups and favela residents coexist with environmental preservation areas, beaches and commercial activities. This work revealed the need for contextualized sanitation information made available by the Brazilian Institute of Geography and Statistics (IBGE) and state sewage collection company, which conceal these conflicts or the representation of residents about their sanitation problems. Overlapping territorial managing functions should be considered as one of the factors responsible for the conflicts identified in the neighborhood. Further studies are suggested as methodological complementation and data update.

  6. Beneficial uses of nuclear byproducts/sewage sludge irradiation project. Progress report, October 1982-March 1983

    International Nuclear Information System (INIS)

    Pierce, J.D.

    1984-11-01

    Gamma irradiation of various commodities in the Sandia Irradiator for Dried Sewage Solids (SIDSS) and the Gamma Irradiation Facility (GIF) continued during this reporting period. One truck-load of grapefruit was irradiated. Pelletized straw was irradiated to doses of 1, 5, 10, 20, and 40 megarads in SIDSS. Sludge, virus, and fungus samples were irradiated. Infected ground pork and infected pig carcasses were irradiated in the GIF as a method of Trichinella spiralis inactivation. Other experiments conducted in the GIF included irradiation of cut flowers to extend their shelf life and irradiation of kepone to induce its degradation. Waste Encapsulation and Storage Facility (WESF) capsule studies at ORNL and SNLA continued. A purchase order was placed for a prototype sludge solar dryer. Sewage Sludge Irradiation Transportation System (SSITS) cask activities included thermal stress analyses of cask performance following separation from the impact limiters during a fire. Analyses of cask performance, when loaded with six strontium-90 (Sr-90) capsules, also were done

  7. Preparation of sewage treatment material PVFM

    Directory of Open Access Journals (Sweden)

    Wenling YANG

    2018-04-01

    Full Text Available In order to study the optimal operating condition of the sewage treatment material PVFM(polyvinyl formal, the mechanical blowing method and the chemical foaming method are adopted. Single-factor experiments and orthogonal experiments are conducted to study the factors including the amount of raw materials, reaction time and reaction temperature influencing the preparation of the material PVFM. The material is characterized by SEM. The properties of the material are explored through the contrastive experiments of sewage treatment. The results show that when PVA mass concentration is 9% (50 mL, cellulose content is 0.4 g, sulfuric acid content is 6 mL, formaldehyde content is 6 mL, SDS content is 0.4 g, carbonate calcium content is 0.8 g, reaction temperature is 30 ℃, the dripping time of sulfuric acid is 9 minutes, the dripping time of formaldehyde is 4 minutes, and the curing time is 8 hours, the material has good physical and chemical property, and the results of the contrastive experiments of sewage treatment show that PVFM has good removal effects on both COD and NH4+-N in simulated sewage. The sewage treatment material PVFM with good properties can be obtained by the mechanical blowing method and the chemical foaming method.

  8. Supercritical water gasification of sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    Aye, L.; Yamaguchi, D. [Melbourne Univ. International Technologies Centre, Melbourne, Victoria (Australia). Dept. of Civil and Environmental Engineering

    2006-07-01

    Supercritical water gasification (SCWG) is an attractive technology for producing fuels from biomass and waste materials. As a result of greenhouse gas emissions and issues related to local air pollutants, hydrogen production from these renewable energy resources has been gaining in popularity. Disposal of sewage sludge is another environmental problem that have led to severe regulations. Incineration has been one of the most commonly used means of sewage sludge disposal. Thermal gasification produces gaseous fuel, making it a better option over incineration. However, due to its high moisture content, this process is not feasible to make use of sewage sludge directly. In order to analyze SCWG of sewage sludge, it has been determined that equilibrium analysis is most suitable since the maximum achievable amount of hydrogen in a given reacting condition can be estimated. The equilibrium model can be divided into two types of models, namely stoichiometric and non-stoichiometric. This paper presented the results of a study that used a computer program to develop a nonstoichiometric model with the direct Gibbs free energy minimization technique. In addition, various biomass were simulated for comparisons in order to identify if sewage sludge is a potential feedstock for hydrogen production. Last, the effects of reaction pressure and temperature on product distribution were also examined. It was shown that the proposed model is capable of estimating the product distribution at equilibrium. 33 refs., 4 tabs., 6 figs.

  9. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    user

    irradiation sewage water can find its application either in agriculture for irrigation or in industry sector for cooling ... The water samples were collected from sewage water treatment .... to be irrigated, soil conditions and the irrigation system.

  10. Vessel Sewage Discharges: Statutes, Regulations, and Related Laws and Treaties

    Science.gov (United States)

    Vessel sewage discharges can be regulated under multiple statutes, regulations, and laws/treaties, including the Clean Water Act, Title XIV, MARPOL Annex IV and the Vessel General Permit. This page describes how these are applied to vessel sewage.

  11. Lipid profiling in sewage sludge.

    Science.gov (United States)

    Zhu, Fenfen; Wu, Xuemin; Zhao, Luyao; Liu, Xiaohui; Qi, Juanjuan; Wang, Xueying; Wang, Jiawei

    2017-06-01

    High value-added reutilization of sewage sludge from wastewater treatment plants (WWTPs) is essential in sustainable development in WWTPs. However, despite the advantage of high value reutilization, this process must be based on a detailed study of organics in sludge. We used the methods employed in life sciences to determine the profile of lipids (cellular lipids, free fatty acids (FFAs), and wax/gum) in five sludge samples obtained from three typical WWTPs in Beijing; these samples include one sludge sample from a primary sedimentation tank, two activated sludge samples from two Anaerobic-Anoxic-Oxic (A2/O) tanks, and two activated sludge samples from two membrane bioreactor tanks. The percentage of total raw lipids varied from 2.90% to 12.3%. Sludge from the primary sedimentation tank showed the highest concentrations of lipid, FFA, and wax/gum and the second highest concentration of cellular lipids. All activated sludge contained an abundance of cellular lipids (>54%). Cells in sludge can from plants, animals, microbes and so on in wastewater. Approximately 14 species of cellular lipids were identified, including considerable high value-potential ceramide (9567-38774 mg/kg), coenzyme (937-3897 mg/kg), and some phosphatidylcholine (75-548 mg/kg). The presence of those lipid constituents would thus require a wider range of recovery methods for sludge. Both cellular lipids and FFAs contain an abundance of C16-C18 lipids at high saturation level, and they serve as good resources for biodiesel production. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Urban runoff - Swedish experience

    International Nuclear Information System (INIS)

    Falk, Jan

    1987-01-01

    During the past 20 years hard effort has been devoted to the protection of rivers, lakes and the sea from pollution. This effort has mainly been focused on the obvious sources of pollution i.e. the concentrated outlet of sewage. Currently 75% of the urban population is served by advanced treatment plants. Not until recently attention was paid to sewerage. The official policy was that separate storm sewers was the only acceptable system and discharge permits generally required separation of existing combined sewers were to be abandoned there was little concern about overflows

  13. Land application of sewage sludge: Pathogen issues

    Energy Technology Data Exchange (ETDEWEB)

    Chang, A C [Department of Soil and Environmental Sciences, Univ. of California at Riverside, Riverside, CA (United States)

    1997-10-01

    Diseases transmitted via the faecal-oral exposure route cause severe gastroenteric disorders, and large numbers of causative organisms are discharged with the faecal matter of infected individuals. For this reason, pathogenic bacteria, viruses, protozoa, or helminths, are always found in sewage sludge. If not properly treated for use in agriculture, sludge can be a source of pathogenic contamination. Radiation is an attractive method to reduce the numbers of microorganisms in sewage sludge. Routine examination for pathogens is not practised nor recommended because complicated and costly procedures are involved. Instead, an indicator organism is usually assayed and enumerated. In this paper, methods are discussed for the investigation of pathogens in sewage sludge. (author). 8 refs, 3 tabs.

  14. Cs-137 for irradiation of sewage sludge

    International Nuclear Information System (INIS)

    Lessel, T.

    1986-01-01

    Since 1973, the Geiselbullach sewage treatment works have been continuously operating their first system for gamma irradiation of sewage sludge. Within the framework of a German-American agreement, nine Cs-137 sources with a total activity of 56.000 Ci have been made available to the works free of charge in 1983, in order to test in practice and to demonstrate the applicability of these radiation sources in comparison to the Co-60 sources exclusively used up to then. This first study on the applicability of Cs-137 as a radiation source for sewage sludge treatment revealed no findings or effects speaking against Cs-137 as a radiation source for this purpose. (orig./RB) [de

  15. Effect of watershed urbanization on N2O emissions from the Chongqing metropolitan river network, China

    Science.gov (United States)

    He, Yixin; Wang, Xiaofeng; Chen, Huai; Yuan, Xingzhong; Wu, Ning; Zhang, Yuewei; Yue, Junsheng; Zhang, Qiaoyong; Diao, Yuanbin; Zhou, Lilei

    2017-12-01

    Watershed urbanization, an integrated anthropogenic perturbation, is another considerable global concern in addition to that of global warming and may significantly enrich the N loadings of watersheds, which then greatly influences the nitrous oxide (N2O) production and fluxes of these aquatic systems. However, little is known about the N2O dynamics in human-dominated metropolitan river networks. In this study, we present the temporal and spatial variations in N2O saturation and emission in the Chongqing metropolitan river network, which is undergoing intensified urbanization. The N2O saturation and fluxes at 84 sampling sites ranged from 126% to 10536% and from 4.5 to 1566.8 μmol N2O m-2 d-1, with means of 1780% and 261 μmol N2O m-2 d-1. The riverine N2O saturation and fluxes increased along with the urbanization gradient and urbanization rate, with disproportionately higher values in urban rivers due to the N2O-rich sewage inputs and enriched in situ N substrates. We found a clear seasonal pattern of N2O saturation, which was co-regulated by both water temperature and precipitation. Regression analysis indicated that the N substrates and dissolved oxygen (DO) that controlled nitrogen metabolism acted as good predictors of the N2O emissions of urban river networks. Particularly, phosphorus (P) and hydromorphological factors (water velocity, river size and bottom substrate) had stronger relationships with the N2O saturation and could also be used to predict the N2O emission hotspots in regions with rapid urbanization. In addition, the default emission factors (EF5-r) used in the Intergovernmental Panel on Climate Change (IPCC) methodology may need revision given the differences among the physical and chemical factors in different rivers, especially urban rivers.

  16. Impacts from urban water systems on receiving waters - How to account for severe wet-weather events in LCA?

    Science.gov (United States)

    Risch, Eva; Gasperi, Johnny; Gromaire, Marie-Christine; Chebbo, Ghassan; Azimi, Sam; Rocher, Vincent; Roux, Philippe; Rosenbaum, Ralph K; Sinfort, Carole

    2018-01-01

    Sewage systems are a vital part of the urban infrastructure in most cities. They provide drainage, which protects public health, prevents the flooding of property and protects the water environment around urban areas. On some occasions sewers will overflow into the water environment during heavy rain potentially causing unacceptable impacts from releases of untreated sewage into the environment. In typical Life Cycle Assessment (LCA) studies of urban wastewater systems (UWS), average dry-weather conditions are modelled while wet-weather flows from UWS, presenting a high temporal variability, are not currently accounted for. In this context, the loads from several storm events could be important contributors to the impact categories freshwater eutrophication and ecotoxicity. In this study we investigated the contributions of these wet-weather-induced discharges relative to average dry-weather conditions in the life cycle inventory for UWS. In collaboration with the Paris public sanitation service (SIAAP) and Observatory of Urban Pollutants (OPUR) program researchers, this work aimed at identifying and comparing contributing flows from the UWS in the Paris area by a selection of routine wastewater parameters and priority pollutants. This collected data is organized according to archetypal weather days during a reference year. Then, for each archetypal weather day and its associated flows to the receiving river waters (Seine), the parameters of pollutant loads (statistical distribution of concentrations and volumes) were determined. The resulting inventory flows (i.e. the potential loads from the UWS) were used as LCA input data to assess the associated impacts. This allowed investigating the relative importance of episodic wet-weather versus "continuous" dry-weather loads with a probabilistic approach to account for pollutant variability within the urban flows. The analysis at the scale of one year showed that storm events are significant contributors to the impacts

  17. Continuous COD measurement in sewage receipts at sewage treatment plants; Kontinuierliche CSB-Messung im Klaeranlagenzulauf

    Energy Technology Data Exchange (ETDEWEB)

    Pirsing, A. [Siemens AG, Anlagentechnik/Wasserwirtschaft (ATD TD ISA 6), Karlsruhe (Germany)

    1997-11-01

    Neural networks are a new instrument in process automation. Contrary to conventional methods, they can dispense with theoretical models. This independence from mathematical models is one of their most important advantages. The article describes how typical sewage parameters can be measured on-line by means of neural networks. On-line measurement of parameters of pollution, for instance COD in sewage, permits new automatic control strategies for the operation of a sewage treatment plant, aiming at the reduction of pollutant freights with simultaneous minimization of operating cost. (orig./SR)

  18. Polybrominated diphenyl ethers in sewage sludge from Shanghai, China: possible ecological risk applied to agricultural land.

    Science.gov (United States)

    Yang, Chao; Meng, Xiang-Zhou; Chen, Ling; Xia, Siqing

    2011-10-01

    Ideally, agricultural use is a treatment for the sewage sludge generated from municipal wastewater. However, this treatment probably causes ecological risks due to the occurrence of organic contaminants in sludge, which has attracted rising concerns recently. To assess the possible ecological risk, in this study, sewage sludge samples were collected from 28 wastewater treatment plants (WWTPs) in Shanghai, China for exploring the level and profile of polybrominated diphenyl ethers (PBDEs). The mean concentration of Σ18PBDE (sum of all target analytes except for BDE-209) was at the low end of global range. However, we found the highest reported BDE-209 levels (34,900 ng g(-1) dw) in sewage sludge/biosoilds to date. The annual mass loadings of penta-BDE, octa-BDE, and deca-BDE were 3.6, 0.6, and 763 kg through sludge, respectively. Following sludge application in agricultural land, the concentrations of penta-BDE, octa-BDE, and deca-BDE in soil were 0.19, 0.03, and 39.5 ng g(-1), respectively. Preliminary results indicate that the ecological risk of soil in organisms exposed to PBDEs was relatively low. Nevertheless, further studies are needed to explore the fate of PBDEs in sewage sludge due to no restriction on the usage and production of PBDEs products in China currently. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Elemental transport and distribution in soils amended with incinerated sewage sludge.

    Science.gov (United States)

    Paramasivam, S; Sajwan, K S; Alva, A K; VanClief, D; Hostler, K H

    2003-05-01

    Sewage sludge (SS) is the major solid waste of sewage and wastewater treatment plants in cities around the world. Even though treated effluent water from wastewater treatment plants are utilized for irrigation, disposal of sewage sludge is becoming a serious problem. This is due to its high content of certain heavy metals still posing threat of accumulation in plants and groundwater contamination when it is used as soil amendment or disposed in landfills. Water treatment plants incinerate the dewatered activated sewage sludge (ISS) and dissolve the ash in water to store in ash ponds for long-term storage (WISS). A study was undertaken to evaluate the transport and leaching potential of various elements and their distribution within soil columns amended with various rates of ISS. Results of this study indicates that ISS from wastewater treatment plants can be used as soil amendment on agricultural lands at low to medium rates (< or = 100 Mg ha(-1)) without causing potential loading of metals into groundwater.

  20. 33 CFR 159.121 - Sewage processing test.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Sewage processing test. 159.121...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.121 Sewage processing test. (a) The device must process human sewage in the manner for which it is designed when tested in accordance...

  1. Submersible microbial fuel cell for electricity production from sewage sludge

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Olias, Lola Gonzalez; Kongjan, Prawit

    2010-01-01

    A submersible microbial fuel cell (SMFC) was utilized to treatment of sewage sludge and simultaneous generate electricity. Stable power generation (145±5 mW/m2) was produced continuously from raw sewage sludge for 5.5 days. The corresponding total chemical oxygen demand (TCOD) removal efficiency...... of an effective system to treatment of sewage sludge and simultaneous recover energy....

  2. 21 CFR 211.50 - Sewage and refuse.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sewage and refuse. 211.50 Section 211.50 Food and... CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Buildings and Facilities § 211.50 Sewage and refuse. Sewage, trash, and other refuse in and from the building and immediate premises shall be...

  3. Wastes to Resources: Appropriate Technologies for Sewage Treatment and Conversion.

    Science.gov (United States)

    Anderson, Stephen P.

    Appropriate technology options for sewage management systems are explained in this four-chapter report. The use of appropriate technologies is advocated for its health, environmental, and economic benefits. Chapter 1 presents background information on sewage treatment in the United States and the key issues facing municipal sewage managers.…

  4. Iodine-131 monitoring in sewage plant outflow

    International Nuclear Information System (INIS)

    McGowan, D R; Crawley, M T; Pratt, B E; Hinton, P J; Peet, D J

    2014-01-01

    Three different hospital sites (Oxford, Sutton and Guildford) have performed sampling of their local sewage plant outflow to determine levels of radioactivity resulting from iodine-131 patients undergoing radionuclide therapies. It was found that a maximum of 20% of activity discharged from the hospitals was present in the sewage plant final effluent channel. This is significantly below the level predicted by mathematical models in current use. The results further show that abatement systems to reduce public exposure are unlikely to be warranted at hospital sites. (paper)

  5. Enantioselective degradation of Bromocyclene in sewage plants

    Energy Technology Data Exchange (ETDEWEB)

    Bester, K [Duisburg-Essen Univ. (Germany). FG Siedlungswasser- und Abfallwirtschaft/Inst. fuer Umweltanalytik

    2004-09-15

    Bromocyclene has been utilised as insecticide against ectoparasites, however the production in Germany was stopped around 1995. Until that time it was used in pet care as well as in sheep farming. Due to its high bioaccumulation it was detected not only in sewage systems and sewage treatment plants, but also in fresh water fish. Enatioselective determination at that time was used to obtain results on the biodegradation of Bromocyclene in fish. Considering the long time period since the phase out of Bromocyclene it was surprising it was easily identified in sludge samples from 2002.

  6. Radioactive contamination of sewage sludge. Preliminary data

    Energy Technology Data Exchange (ETDEWEB)

    Soeder, C J; Zanders, E; Raphael, T

    1986-01-01

    Because of the radioactivity released through the explosion of the nuclear reactor near Chernobyl radionuclides have been accumulated to a significant extent in sewage sludge in the Federal Republic of Germany. This is demonstrated for samples from four activated sludge plants according to a recent recommendation of the German Commission for Radiation Protection, there is until now no reason to deviate from the common practices of sludge disposal or incineration. The degree of radioactive contamination of plant materials produced on farm lands on which sewage sludge is being spread cannot be estimated with sufficient certainty yet. Additional information is required.

  7. Radiation treatment of sewage effluent, (2)

    International Nuclear Information System (INIS)

    Sawai, Teruko; Sekiguchi, Masayuki; Sawai, Takeshi; Shimokawa, Toshinari; Tanabe, Hiroko

    1991-01-01

    The water demand of the past several years has increased rapidly. Recycling of municipal waste water is an effective mean of coping with the water shortage in Tokyo. We studied the radiation treatment method of further purification of the effluent from sewage treatment plants. By gamma irradiation the refractory organic substances in the effluent were decomposed and the COD values decreased with increasing dose. The high molecular weight components in the effluent were degraded to lower molecular weight substances and were decomposed finally to carbon dioxide. In this paper we studied on the fading color and the reducing of order of sewage effluent. (author)

  8. 2010 Annual Wastewater Reuse Report for the Idaho National Laboratory Site's Central Facilities Area Sewage Treatment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Mike lewis

    2011-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2009, through October 31, 2010. The report contains the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of special compliance conditions • Discussion of the facility’s environmental impacts. During the 2010 permit year, approximately 2.2 million gallons of treated wastewater was land-applied to the irrigation area at Central Facilities Area Sewage Treatment plant.

  9. Modeling urban flood risk territories for Riga city

    Science.gov (United States)

    Piliksere, A.; Sennikovs, J.; Virbulis, J.; Bethers, U.; Bethers, P.; Valainis, A.

    2012-04-01

    the Gumbell extreme value analysis. The hydrological modelling driven by the temperature and precipitation data series from regional climate models were used for evaluation of rain event maximums in the future periods. The usage of the climate model data in hydrological models causes systematic errors; therefore the bias correction method (Sennikovs, Bethers, 2009) was applied for determination of the future rainfall intensities. SWMM model was built for the urban area. Objects of hydraulic importance (manifold, penstock, ditch, pumping station, weir, well, catchment sub-basin etc.) were included in the model. There exist pure rain sewage system and mixed rain-water/household sewage system in Riga. Sewage system with wastewater load proportional to population density was taken account and calibrated. Model system was calibrated for a real rain event against the water flux time series into sewage treatment plant of Riga. High resolution (~1.5 points per square meter) digital terrain map was used as the base for finite element mesh for the geospatial mapping of results of hydraulic calculations. Main results of study are (1) detection of the hot spots of densely populated urban areas; (2) identification of the weak chains of the melioration and sewage systems; (3) mapping the elevation of ground water mainly caused by snow melting. A.Piliksere, A.Valainis, J.Seņņikovs, (2011), A flood risk assessment for Riga city taking account climate changes, EGU, Vienna, Austria. EPA, (2004), Storm water management model. User's manual version 5.0. US Environmental Protection Agency J.Sennikovs, U.Bethers, (2009), Statistical downscaling method of regional climate model results for hydrological modelling. 18th World IMACS/MODSIM Congress, Cairns, Australia.

  10. Sewage pollution in Negril, Jamaica: effects on nutrition and ecology of coral reef macroalgae

    Science.gov (United States)

    Lapointe, B. E.; Thacker, K.; Hanson, C.; Getten, L.

    2011-07-01

    Coral reefs in the Negril Marine Park (NMP), Jamaica, have been increasingly impacted by nutrient pollution and macroalgal blooms following decades of intensive development as a major tourist destination. A baseline survey of DIN and SRP concentrations, C:N:P and stable nitrogen isotope ratios (δ15N) of abundant reef macroalgae on shallow and deep reefs of the NMP in 1998 showed strong P-limitation and evidence of increasing sewage pollution. In 1999, a sewage collection and treatment project began diverting wastewater from the resort and urban areas to a pond system that discharged partially-treated effluent into the South Negril River (SNR). These sewage discharges significantly increased concentrations of NH{4/+} and SRP (N:P ˜13) in the SNR, which flows into Long Bay and around Negril's "West End". Concentrations of SRP, the primary limiting nutrient, were higher on shallow reefs of the West End in 2001 compared to 1998. Stable nitrogen isotope ratios (δ15N) of abundant reef macroalgae on both shallow and deep reefs of the West End in 2002 were significantly higher than baseline values in 1998, indicating an escalating impact of sewage nitrogen pollution over this timeframe. The increased nutrient concentrations and δ15N enrichment of reef macroalgae correlated with blooms of the chlorophyte Chaetomorpha linum in shallow waters of Long Bay and Codium isthmocladum and Caulerpa cupressoides on deep reefs of the West End. Sewage treatment systems adjacent to coral reefs must include nutrient removal to ensure that DIN and SRP concentrations, after dilution, are below the low thresholds noted for these oligotrophic ecosystems.

  11. Investigation of sewage contamination using steroid indexes in sediments of the Guajará Estuary (Amazon coast, Brazil

    Directory of Open Access Journals (Sweden)

    Heyde Gonçalves Gomes

    2015-12-01

    Full Text Available Abstract Amazonian aquatic systems are usually associated with pristine waters, however, irregular urban occupation of the hydrographic basins and sewerage deficiencies may lead to point and diffuse contamination. Sewage contamination in intertidal surface sediments from the Guajará Estuary, Brazilian Amazon coast, was evaluated using a set of steroids as biomarkers. Sediments collected along the urbanized margin were also analyzed for chlorophyll a, total organic carbon and grain sizes. Coprostanol, the main fecal sterol, was found at concentrations varying from 0.06 to 7.93 µg g-1 dry sediment, following the sequence Tucunduba > Ver-o-Peso > Porto da Palha > Tamandaré > Icoaraci > Miramar. Mixed sources of organic matter and coastal process probably concurred to produce weak correlations among the parameters. Plant derived sterols, including n-C30 alcohol and β-amyrinyl alkanoates, were clearly abundant, but they did not preclude the use of other steroid signals to the assessment of sewage contamination. High values of the steroid indexes involving 5α and 5β stanols and stanones highlighted sewage contamination at the sites with the lowest absolute coprostanol concentrations. The predominance of 5β stanols indicated a chronically sewage contamination of the area.

  12. Electrokinetic extraction of surfactants and heavy metals from sewage sludge

    International Nuclear Information System (INIS)

    Ferri, Violetta; Ferro, Sergio; Martinez-Huitle, Carlos A.; De Battisti, Achille

    2009-01-01

    Waste management represents a quite serious problem involving aspects of remediation technologies and potential re-utilization in different fields of human activities. Of course, wastes generated in industrial activities deserve more attention because of the nature and amount of xenobiotic components, often difficult to be eliminated. However, also ordinary wastes of urban origin are drawing more and more attention, depending on the concentration of noxious substances like surfactants and some heavy metal, which may eventually require expensive disposal. In the present paper, a research has been carried out on the application of electrokinetic treatments for the abatement of the above xenobiotic components from sewage sludge generated in urban wastewater treatment plants. Experiments were carried out on a laboratory scale, in a 250 mm x 50 mm x 100 mm cell, using 250-300 g of sludge for each test and current densities between 2.4 and 5.7 mA cm -2 . As a general result, quite significant abatements of heavy-metal ions and surfactants were achieved, with relatively low energy consumption

  13. Evaluation of leafy vegetables as bioindicators of gaseous mercury pollution in sewage-irrigated areas.

    Science.gov (United States)

    Zheng, Shun-An; Wu, Zeying; Chen, Chun; Liang, Junfeng; Huang, Hongkun; Zheng, Xiangqun

    2018-01-01

    Mercury (Hg) can evaporate and enter the plants through the stomata of plant leaves, which will cause a serious threat to local food safety and human health. For the risk assessment, this study aimed to investigate the concentration and accumulation of total gaseous mercury (TGM) in five typical leafy vegetables (Chinese chives (Allium tuberosum Rottler), amaranth (Amaranthus mangostanus L.), rape (Brassica campestris L.), lettuce (Lactuca sativa L.), and spinach (Spinacia oleracea L.)) grown on sewage-irrigated areas in Tianjin, China. The following three sites were chosen to biomonitor Hg pollution: a paddy field receiving sewage irrigation (industrial and urban sewage effluents) for the last 30 years, a vegetable field receiving sewage irrigation for 15 years, and a grass field which did not receive sewage irrigation in history. Results showed that the total Hg levels in the paddy (0.65 mg kg -1 ) and vegetation fields (0.42 mg kg -1 ) were significantly higher than the local background level (0.073 mg kg -1 ) and the China national soil environment quality standard for Hg in grade I (0.30 mg kg -1 ). The TGM levels in ambient air were significantly higher in the paddy (71.3 ng m -3 ) and vegetable fields (39.2 ng m -3 ) relative to the control (9.4 ng m -3 ) and previously reported levels (1.45 ng m -3 ), indicating severe Hg pollution in the atmospheric environment of the sewage-irrigated areas. Furthermore, gaseous mercury was the dominant form of Hg uptake in the leaves or irreversibly bound to leaves. The comparison of Hg uptake levels among the five vegetables showed that the gradient of Hg accumulation followed the order spinach > red amaranth > Chinese chives > rape > lettuce. These results suggest that gaseous Hg exposure in the sewage-irrigated areas is a dominant Hg uptake route in leafy vegetables and may pose a potential threat to agricultural food safety and human health.

  14. PBDEs in Italian sewage sludge and environmental risk of using sewage sludge for land application

    International Nuclear Information System (INIS)

    Cincinelli, Alessandra; Martellini, Tania; Misuri, Lorenza; Lanciotti, Eudes; Sweetman, Andy; Laschi, Serena; Palchetti, Ilaria

    2012-01-01

    Polybrominated diphenyl ethers (PBDEs) were determined in sewage sludge samples collected from eight Italian wastewater treatment plants (WWTPs) between June 2009 and March 2010. Total PBDE concentrations ranged from 158.3 to 9427 ng g −1 dw, while deca-BDE (BDE-209) (concentrations ranging from 130.6 to 9411 ng g −1 dw) dominated the congener profile in all the samples, contributing between 77% and 99.8% of total PBDE. The suitability of using a magnetic particle enzyme-linked immunoassay (ELISA) to analyse PBDEs in sewage sludge was also tested. The ELISA results, expressed as BDE-47 equivalents, were well correlated with those obtained by GC–NCI–MS, with correlation coefficients (r 2 ) of 0.899 and 0.959, depending on the extraction procedure adopted. The risk assessment of PBDEs in sewage sludge addressed to land application was calculated. PEC soil values compared to the relative PNEC soil for penta and deca-BDE suggests that there is a low risk to the soil environment. - Highlights: ► PBDEs in sewage sludge were determined in eight Italian WWTPs for the first time. ► PBDEs concentrations showed differences between the eight investigated WWTPs. ► Deca-BDE (BDE-209) was the dominant congener in all samples. ► The suitability of using ELISA method to analyse PBDEs in sewage sludge was tested. ► The risk assessment of using sewage sludge for land application was evaluated. - Determination of PBDEs in sewage sludge by GC–NCI–MS and ELISA test and risk assessment when sewage sludge is used for land application.

  15. 8. European sewage and refuse symposium. Documentation

    International Nuclear Information System (INIS)

    1990-01-01

    The subject of the 8. European Sewage and Refuse Symposium is covered under the following headings: collection and control in sewers, industrial waste water management, pretreatment, combined treatment, special cases, industrial waste water sludges disposal and the European waste business. (orig./BBR)

  16. Sewage Effluent Infiltrates Frozen Forest Soil

    Science.gov (United States)

    Alfred Ray Harris

    1976-01-01

    Secondarily treated sewage effluent, applied at the rate of 1 and 2 inches per week, infiltrated a frozen Sparta sand soil forested with jack pine and scrub oak. Maximum frost depth in treated plots averaged 60 cm and in check plots averages 35 cm. Nitrogen was mobile with some accumulation. Phosphorus was absorbed.

  17. Gamma irradiation treatment of secondary sewage effluent

    International Nuclear Information System (INIS)

    Vajdic, A.H.

    The operation and monitoring of a pilot scale Co-60 gamma irradiation unit treating secondary sewage effluent is described. The disinfecting efficiency of the unit is compared to that of an experimental 'ideal' chlorination unit and to the plant chlorination process. A cost estimate for disinfection by gamma irradiation on a full plant scale is included. (author)

  18. Phosphorus recovery from sewage sludge char ash

    NARCIS (Netherlands)

    Atienza-Martinez, M.; Gea, G.; Arauzo, J.; Kersten, Sascha R.A.; Kootstra, A.M.J.

    2014-01-01

    Phosphorus was recovered from the ash obtained after combustion at different temperatures (600 °C, 750 °C and 900 °C) and after gasification (at 820 °C using a mixture of air and steam as fluidising agent) of char from sewage sludge fast pyrolysis carried out at 530 °C. Depending on the leaching

  19. Home Sewage Disposal. Special Circular 212.

    Science.gov (United States)

    Wooding, N. Henry

    This circular provides current information for homeowners who must repair or replace existing on-lot sewage disposal systems. Site requirements, characteristics and preparation are outlined for a variety of alternatives such as elevated sand mounds, sand-lined beds and trenches, and oversized absorption area. Diagrams indicating construction…

  20. Heavy metals precipitation in sewage sludge

    NARCIS (Netherlands)

    Marchioretto, M.M.; Rulkens, W.H.; Bruning, H.

    2005-01-01

    There is a great need for heavy metal removal from strongly metal-polluted sewage sludges. One of the advantages of heavy metal removal from this type of sludge is the possibility of the sludge disposal to landfill with reduced risk of metals being leached to the surface and groundwater. Another

  1. Tomatoes from the sewage treatment works

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    In Stendsund a sewage cleaning method was developed in which waste water is subjected to a special treatment in order to regain nutrients which would otherwise aggravate the pollution of the Baltic Sea and to use them as fertilizer and food for food plants and fish. Structure and mode of operation of the method are described. (BWI) [de

  2. Changes on sewage sludge stability after greenhouse drying

    Science.gov (United States)

    Soriano-Disla, J. M.; Houot, S.; Imhoff, M.; Valentin, N.; Gómez, I.; Navarro-Pedreño, J.

    2009-04-01

    The progressive implementation of the Urban Waste Water Treatment Directive 91/271/EEC in all the European member states is increasing the quantities of sewage sludge requiring disposal. Sludge application onto cultivated soils as organic fertilizers allows the recycling of nutrients. The application of only dehydrated sludges has generated many problems including unpleasant odours and difficult management (regarding transport and application) related to their high water content. One way to overcome these problems, in a cheap and clean way, is the drying of sludges using the energy of the sun under greenhouse conditions. This drying may affect sludge chemical characteristics including organic matter stability and nitrogen availability, parameters which have to be controlled for the proper management of dry sludge application onto soils. For this reason, the main aim of this work was to study the impact of greenhouse drying of different sewage sludges on their organic matter stability and nitrogen availability, assessed by biochemical fractionation and mineralization assays. Three sewage sludges were sampled before (dehydrated sludges) and after greenhouse drying (dried sludges). The analyses consisted of: humidity, organic matter, mineral and organic N contents, N and C mineralization during 91-day laboratory incubations in controlled conditions, and biochemical fractionation using the Van Soest procedure. Greenhouse drying decreased the water content from 70-80% to 10% and also the odours, both of which will improve the management of the final product from the perspective of application and transport. We also found that drying reduced the organic matter content of the sludges but not the biodegradability of the remaining carbon. Organic N mineralization occurred during greenhouse drying, explaining why mineral N content tended to increase and the potential mineralization of organic nitrogen decreased after greenhouse drying. The biochemical stability did not

  3. Sustainable sewage management and the inertia to change

    Science.gov (United States)

    Öberg, G.

    2012-12-01

    Increasing economic costs and environmental concerns have led to that planners around the world are progressively questioning the prevailing sewage management paradigm, calling for a shift in the hydrosocial contract to embrace more sustainable solutions, to be based on closed-loops rather than linear end-of-pipe solutions. Despite considerable attention to the technical possibilities for delivering sewage services in a more integrated and sustainable fashion, shifts in planning and management have been slow. Based on an extensive study of Australian cities, Brown et al (2009) have developed a model with six transitional stages and argue that "while there may be cognitive changes (best practice thinking such as water sustainable urban design), there has not been sufficient normative and regulative change to support new practice." They contrast three historic transition stages with three successive sustainable stages. Unfortunately, the study ends in a rather vague outline of "the Water Sensitive City", with little sign-posts indicating how one might transition to this seemingly utopian last stage. In the present paper, we discuss the normative tensions created between the different actors in this increasingly complex playing field, who represent different and often competing values. We suggest that cities have difficulties transitioning from the old contract to one of the newer ones because the hydro-social contract promised by these new stages create normative tensions not only between the new and the old, but also between what one might call different types of environmentalists: naturalists and pragmatists. The naturalists, who for example are very voiced in several cities along the North American west coast, tend to embrace the perception of Nature described by environmental historians as Untouched Wilderness, where technology is pinpointed as the root of the problems. In contrast, the other side lean more on the idea of modernity, with a more pragmatic approach

  4. In-situ caustic generation from sewage: the impact of caustic strength and sewage composition.

    Science.gov (United States)

    Pikaar, Ilje; Rozendal, René A; Rabaey, Korneel; Yuan, Zhiguo

    2013-10-01

    Periodic caustic dosage is a commonly used method by the water industry to elevate pH levels and deactivate sewer biofilms responsible for hydrogen sulfide generation. Caustic (NaOH) can be generated in-situ from sewage using a divided electrochemical cell, which avoids the need for transport, handling and storage of concentrated caustic solutions. In this study, we investigated the impact of caustic strength in the cathode compartment and the impact of sodium concentration in sewage on the Coulombic efficiency (CE) for caustic generation. The CE was found to be independent of the caustic strength produced in the range of up to ~3 wt%. Results showed that a caustic solution of ~3 wt% could be produced directly from sewage at a CE of up to 75 ± 0.5%. The sodium concentration in sewage had a significant impact on the CE for caustic generation as well as on the energy requirements of the system, with a higher sodium concentration leading to a higher CE and lower energy consumption. The proton, calcium, magnesium and ammonium concentrations in sewage affected the CE for caustic generation, especially at low sodium concentrations. Economical assessment based on the experimental results indicated that sulfide control in sewers using electrochemically-generated caustic from sewage is an economically attractive strategy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Predicting phosphorus concentrations in British rivers resulting from the introduction of improved phosphorus removal from sewage effluent

    International Nuclear Information System (INIS)

    Bowes, Michael J.; Neal, Colin; Jarvie, Helen P.; Smith, Jim T.; Davies, Helen N.

    2010-01-01

    Phosphorus (P) concentration and flow data gathered during the 1990s for a range of British rivers were used to determine the relative contributions of point and diffuse inputs to the total P load, using the Load Apportionment Model (LAM). Heavily urbanised catchments were dominated by sewage inputs, but the majority of the study catchments received most of their annual phosphorus load from diffuse sources. Despite this, almost 80% of the study sites were dominated by point source inputs for the majority of the year, particularly during summer periods when eutrophication risk is greatest. This highlights the need to reduce sewage P inputs to improve the ecological status of British rivers. These modelled source apportionment estimates were validated against land-use data and boron load (a chemical marker for sewage). The LAM was applied to river flow data in subsequent years, to give predicted P concentrations (assuming no change in P source inputs), and these estimates were compared with observed concentration data. This showed that there had been significant reductions in P concentration in the River Thames, Aire and Ouse in the period 1999 to 2002, which were attributable to the introduction of P stripping at sewage treatment works (STW). The model was then used to forecast P concentrations resulting from the introduction of P removal at STW to a 2 or 1 mg l -1 consent limit. For the urbanised rivers in this study, the introduction of phosphorus stripping to a 1 mg l -1 consent level at all STW in the catchment would not reduce P concentrations in the rivers to potentially limiting concentrations. Therefore, further sewage P stripping will be required to comply with the Water Framework Directive. Diffuse P inputs may also need to be reduced before some of the highly nutrient-enriched rivers achieve good ecological status.

  6. Green infrastructure and urban sustainability

    Science.gov (United States)

    Hagishima, Aya

    2018-02-01

    Temperature increase in urban areas due to the urban heat island as well as the global climate change inevitably raises the peak load supply for space cooling as well as the risk of heat-related illness in hot climate. This paper provides the comprehensive review of the thermal mitigation effect of urban vegetation based on the field observations.

  7. Radionuclides in sewage sludge and problems of use and disposal

    International Nuclear Information System (INIS)

    Schneider, P.; Tiefenbrunner, F.; Dierich, M.P.; Brunner, P.

    1987-01-01

    In a sewage plant with radioactive contaminated sewage an accumulation of radionuclide in the sewage sludge was to be found. The specific activities are in inverse proportion to the water content of the sewage sludge, the dehydrated sewage sludge shows the highest specific activities. These enriched radionuclides seem to be absorbed from the sludge. Yet they can be utilized by plants. This was demonstrated in experiments with Trifolium repens and Secale cereale, where the rate of absorption amounted 15-33% (inCi/kg dry weight plant:nCi/kg dry weight soil X 100) (transfer factors). This is why fertilization with radioactive contaminated sewage sludge seems to cause problems. In further experiments an extraction of radionuclides from ashed sewage sludge was shown. By acidifying the mobile phasis an increase in radioactivity in the eluated fractions was achieved. (orig./HP) [de

  8. Combustion characteristics of biodried sewage sludge.

    Science.gov (United States)

    Hao, Zongdi; Yang, Benqin; Jahng, Deokjin

    2018-02-01

    In this study, effects of biodrying on the characteristics of sewage sludge and the subsequent combustion behavior were investigated. 7-Day of biodrying removed 49.78% of water and 23.17% of VS initially contained in the sewage sludge and increased lower heating value (LHV) by 37.87%. Meanwhile, mass contents of C and N decreased from 36.25% and 6.12% to 32.06% and 4.82%, respectively. Surface of the biodried sewage sludge (BDSS) appeared granulated and multi-porous, which was thought to facilitate air transfer during combustion. According to thermogravimetric (TG) analysis coupled with mass spectrometer (MS) with a heating rate of 10 °C/min from 35 °C to 1000 °C, thermally-dried sewage sludge (TDSS) and BDSS lost 74.39% and 67.04% of the initial mass, respectively. In addition, combustibility index (S) of BDSS (8.67 × 10 -8  min -2  K -3 ) was higher than TDSS. TG-MS analyses also showed that less nitrogenous gases were generated from BDSS than TDSS. It was again showed that the average CO and NO concentrations in exit gas from isothermal combustion of BDSS were lower than those from TDSS, especially at low temperatures (≤800 °C). Based on these results, it was concluded that biodrying of sewage sludge was an energy-efficient water-removal method with less emission of air pollutants when BDSS was combusted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Recycling by the brick making industry of ashes from sewage sludge incineration; Verwertung von Aschen der Klaerschlammverbrennung in der Ziegelindustrie

    Energy Technology Data Exchange (ETDEWEB)

    Wiebusch, B.; Seyfried, C.F. [Hannover Univ. (Germany). ISAH Inst. fuer Siedlungswasserwirtschaft und Abfalltechnik

    1998-09-01

    The present project focuses on the recycling of sewage sludge ashes by the brick making industry. The following aspects are dealt with in detail: Overview of the state of the art of sewage sludge combustion in Germany; influence of wastewater and sludge treatment on ash quality (determination of the seasonal course of chemical sewage sludge composition); use of sewage sludge ashes in as loading material in fluidised-bed furnaces or as clay substitute in brick manufacture; semi-technical trials in ceramic laboratories; assessment of the environmental impact of bricks containing sewage sludge ash; performance of leaching experiments; and examination of the mineralogical binding of heavy metals into the ceramic matrix. [Deutsch] Das Projekt konzentriert sich dabei auf eine Verwertung von Klaerschlammaschen in der Ziegelindustrie, wobei die im folgenden genannten Aspekte im Einzelnen bearbeitet werden: - Ueberblick ueber den Stand der Technik bei der Klaerschlammverbrennung in Deutschland - Einfluss der Abwasser- und Schlammbehandlung auf die Aschequalitaet (Ermittlung von Jahresganglinien der chemischen Zusammensetzung von Klaerschlammaschen) - Einsatz von Klaerschlammaschen aus Wirbelschichtoefen als Zuschlagstoff bzw. Tonersatz bei der Ziegelproduktion - halbtechnische Versuche im keramischen Labor - Abschaetzung der Umweltvertraeglichkeit von Ziegeln mit Klaerschlammaschezusatz: Durchfuehrung von Auslangversuchen, Untersuchung einer mineralogischen Einbindung von Schwermetallen in die keramische Matrix. (orig./SR)

  10. Biogeochemistry and community ecology in a spring-fed urban river following a major earthquake

    International Nuclear Information System (INIS)

    Wells, Naomi S.; Clough, Tim J.; Condron, Leo M.; Baisden, W. Troy; Harding, Jon S.; Dong, Y.; Lewis, G.D.; Lear, Gavin

    2013-01-01

    In February 2011 a M W 6.3 earthquake in Christchurch, New Zealand inundated urban waterways with sediment from liquefaction and triggered sewage spills. The impacts of, and recovery from, this natural disaster on the stream biogeochemistry and biology were assessed over six months along a longitudinal impact gradient in an urban river. The impact of liquefaction was masked by earthquake triggered sewage spills (∼20,000 m 3 day −1 entering the river for one month). Within 10 days of the earthquake dissolved oxygen in the lowest reaches was −1 , in-stream denitrification accelerated (attenuating 40–80% of sewage nitrogen), microbial biofilm communities changed, and several benthic invertebrate taxa disappeared. Following sewage system repairs, the river recovered in a reverse cascade, and within six months there were no differences in water chemistry, nutrient cycling, or benthic communities between severely and minimally impacted reaches. This study highlights the importance of assessing environmental impact following urban natural disasters. -- Highlights: •Earthquakes triggered sewage spills and liquefaction into an urban river. •Combined chemical, isotopic, and biological measurements to quantify stream recovery. •Sustained sewage discharge into the river drove eutrophication in lower reaches. •River function recovered in a reverse cascade, from chemical to macroinvertebrate. -- Linking stream community ecology with biogeochemical function, we provide an in-depth quantification of urban stream recovery following a catastrophic earthquake

  11. COMPOSITIONAL ANALYSIS OF THE SEWAGE INCOMING TO AND DISCHARGED FROM THE SEWAGE TREATMENT PLANT IN KOLBUSZOWA DOLNA

    Directory of Open Access Journals (Sweden)

    Krzysztof Chmielowski

    2016-11-01

    Full Text Available The paper presents the compositional analysis of sewage supplied to and discharged from the wastewater treatment plant in Kolbuszowa Dolna in the Subcarpathian region. The analysis was based on three basic indicators of sewage pollution (BOD5, CODCr, total suspended solids and two biogenic indicators (total nitrogen and total phosphorus. The composition of sewage was studied in the years 2010–2015. Basic descriptive statistics for the values of the analyzed indicators of sewage pollution were summarized and the obtained results were interpreted. The study showed that the sewage was susceptible to biological treatment. Descriptive statistics for the relationship between the following indicators were presented: CODCr/BOD5, BOD5/Ntot, BOD5/Ptot. The collected results indicate high variability of the composition of sewage entering the studied facility. The coefficients of variation for the values of basic indicators (BOD5, CODCr, total suspended solids in the raw sewage were similar and amounted to Wn = 0.45 while for total nitrogen it was Wn = 0.33 and for total phosphorus Wn = 0.40. The analysis of the collected material showed that sewage entering the treatment plant was readily biodegradable. On the other hand, the treated sewage was characterized by low values of the analyzed indicators, much below the permissible values provided by the water permit. The raw sewage was divided into five groups depending on the concentration of each pollution indicator. The number of raw sewage samples was determined for each group of the analyzed pollution indicator concentrations.

  12. Front-loading urban stormwater management for success – a perspective incorporating current studies on the implementation of retrofit low-impact development

    Science.gov (United States)

    Recent work into the implementation of low-impact development and green infrastructure suggests that a decentralized, source-control approach has the potential to significantly reduce urban stormwater runoff quantity. We posit that the factors of increasing public participation i...

  13. Effects of rainfalls variability and physical-chemical parameters on enteroviruses in sewage and lagoon in Yopougon, Côte d'Ivoire

    Science.gov (United States)

    Momou, Kouassi Julien; Akoua-Koffi, Chantal; Traoré, Karim Sory; Akré, Djako Sosthène; Dosso, Mireille

    2017-07-01

    The aim of this study was to assess the variability of the content of nutrients, oxidizable organic and particulate matters in raw sewage and the lagoon on the effect of rainfall. Then evaluate the impact of these changes in the concentration of enteroviruses (EVs) in waters. The sewage samples were collected at nine sampling points along the channel, which flows, into a tropical lagoon in Yopougon. Physical-chemical parameters (5-day Biochemical Oxygen Demand, Chemical Oxygen Demand, Suspended Particulate Matter, Total Phosphorus, Orthophosphate, Total Kjeldahl Nitrogen and Nitrate) as well as the concentration of EV in these waters were determined. The average numbers of EV isolated from the outlet of the channel were 9.06 × 104 PFU 100 ml-1. Consequently, EV was present in 55.55 and 33.33 % of the samples in the 2 brackish lagoon collection sites. The effect of rainfall on viral load at the both sewage and brackish lagoon environments is significant correlate (two-way ANOVA, P < 0.05). Furthermore, in lagoon environment, nutrients (Orthophosphate, Total Phosphorus), 5-day Biochemical Oxygen Demand, Chemical Oxygen Demand and Suspended Particulate Matter were significant correlated with EVs loads ( P < 0.05 by Pearson test). The overall results highlight the problem of sewage discharge into the lagoon and correlation between viral loads and water quality parameters in sewage and lagoon.

  14. Possible Applications of Hardening Slurries with Fly Ash from Thermal Treatment of Municipal Sewage Sludge in Environmental Protection Structures

    Science.gov (United States)

    Falacinski, Paweł; Szarek, Łukasz

    2016-06-01

    In Poland, in recent years, there has been a rapid accumulation of sewage sludge - a by-product in the treatment of urban wastewater. This has come about as a result of infrastructure renewal, specifically, the construction of modern sewage treatment plants. The more stringent regulations and strategic goals adopted for modern sewage management have necessitated the application of modern engineering methodology for the disposal of sewage sludge. One approach is incineration. As a consequence, the amount of fly ash resulting from the thermal treatment of municipal sewage sludge has grown significantly. Hence, intensive work is in progress for environmentally safe management of this type of waste. The aim of the experiment was to evaluate the possibility of using the fly ash that results from municipal sewage sludge thermal treatment (SSTT) as an additive to hardening slurries. This type of hardening slurry with various types of additives, e.g. coal combustion products, is used in the construction of cut-off walls in hydraulic structures. The article presents the technological and functional parameters of hardening slurries with an addition of fly ash obtained by SSTT. Moreover, the usefulness of these slurries is analysed on the basis of their basic properties, i.e. density, contractual viscosity, water separation, structural strength, volumetric density, hydraulic conductivity, compressive and tensile strength. The mandated requirements for slurries employed in the construction of cut-off walls in flood embankments are listed as a usefulness criteria. The article presents the potential uses of fly ash from SSTT in hardening slurry technology. It also suggests directions for further research to fully identify other potential uses of this by-product in this field.

  15. 40 CFR 503.7 - Requirement for a person who prepares sewage sludge.

    Science.gov (United States)

    2010-07-01

    ... sewage sludge. 503.7 Section 503.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SEWAGE SLUDGE STANDARDS FOR THE USE OR DISPOSAL OF SEWAGE SLUDGE General Provisions § 503.7 Requirement for a person who prepares sewage sludge. Any person who prepares sewage sludge shall ensure that the...

  16. Solute-specific patterns and drivers of urban stream chemistry revealed by long-term monitoring in Baltimore, Maryland

    Science.gov (United States)

    Reisinger, A. J.; Woytowitz, E.; Majcher, E.; Rosi, E. J.; Groffman, P.

    2017-12-01

    Urban streams receive a myriad of chemical inputs from the surrounding landscape due to altered lithology (asphalt, concrete), leaky sewage infrastructure, and other human activities (road salt, fertilizer, industrial wastes, wastewater effluent), potentially leading to multiple chemical stressors occurring simultaneously. To evaluate potential drivers of water chemistry change, we used approximately 20 years of weekly water chemistry monitoring data from streams in the Baltimore Ecosystem Study (BES) to quantify trends of annual loads and flow-weighted concentrations for multiple solutes of interest, including nitrate (NO3-), phosphate (PO43-), total nitrogen (TN), total phosphorus (TP), chloride (Cl-), and sulfate (SO42-) and subsequently examined various gray and green infrastructure characteristics at the watershed scale. For example, we quantified annual volume and duration of reported sanitary sewer overflows (SSO) and cumulative storage volume and area of various best management practices (BMPs). Site- and solute-specific trends differed, but across our monitoring network we found evidence for decreasing annual export for multiple solutes. Additionally, we found that changes in gray- and green-infrastructure characteristics were related to changes in water quality at our most downstream (most urban) monitoring site. For example, annual NO3- loads increased with longer cumulative SSO duration, whereas annual PO43- and TP loads decreased with a cumulative BMP area in the watershed. Further, we used same long-term water chemistry data and multivariate analyses to investigate whether urban streams have unique water chemistry fingerprints representing the multiple chemical stressors at a given site, which could provide insight into sources and impacts of water-quality impairment. These analyses and results illustrate the major role gray and green infrastructure play in influencing water quality in urban environments, and illustrate that focusing on a variety of

  17. [Estimate the abatement rate of septic tank sewage outfall soil on nitrogen pollutants of typical farmer household sewage].

    Science.gov (United States)

    Zhou, Feng; Wang, Wen-Lin; Wang, Guo-Xiang; Ma, Jiu-Yuan; Wan, Yin-Jing; Tang, Xiao-Yan; Liang, Bin; Ji, Bin

    2013-10-01

    The surface soil on sewage outfall and effluent of farmer household septic tank were collected in situ from the typical region of plain river network areas in Taihu Lake Basin, and the typical rainfall (summer 30 mm . times-1, winter 5 mm times -1), temperature (summer 27 degrees C, winter 5 degrees C ) condition and pollutant load were artificial simulated by indoor simulation soil column experiments for estimating nitrogen abatement rate of rural sewage treated by the outfall soil and exploring the abatement rule in different seasons and weather process (7 days before the rain, 3 rainy days, 7 days after the rain). Results showed that: there was the significant difference (P 0. 05). Therefore, the TN, NH+4 -N abatement rate, NO-3 -N increase rate need to be divided by seasons, TN abatement rate, NO-3 -N increase rate of summer need to be divided by the weather process, which were 38.5% , - 25.0% , 46. 0% and 478. 1%, 913.8%, 382. 0% , before the rain, in rainy day, after the rain, respectively; while the NH+4 -N abatement rate of summer and the TN, NH+4 -N abatement rate, NO-3 -N increase rate of winter do not need to be divided by weather process, were 91.7% , 50.4% , 85.5% and 276.0% , respectively. In the summer, the TN abatement rate in different weather processes was not correlated with NH+4 -N abatement rate, but significantly negative correlated with NO-3 -N increase rate. In the winter, the stable accumulation of TN in soil was an important reason of the TN abatement rate which had no significant difference and kept a high level among different weather processes, and it was closely related to the stable accumulation of NH+4 -N in soil.

  18. Experimental study of hydrodynamic and operation start of a baffled anaerobic reactor treating sewage

    Directory of Open Access Journals (Sweden)

    Ana Carolina Silveira Perico

    2009-12-01

    Full Text Available It is important to provide individual sanitation systems for sewage peri-urban communities or rural areas to minimize impacts on the environment and human health caused by sewage discharge in natura into water resources. In this context, the anaerobic digestion of effluent has been one of the main considered technologies due to easy implementation, material minimization and reduction in waste production. The objective of this work was to study a Baffled Anaerobic Reactor (BAR including its hydrodynamic characteristics, percentile of inoculum to be applied and reactor operation start. It was concluded that the flow is dispersed with 3.84% of dead spaces and that 20% of the cow manure provided best results; however, due to the high fiber content of the manure, its use is not recommended as inoculum. The BAR system, composed of four chambers, presented good performance for sewage treatment of a rural community in terms of organic substance removal (COD, turbidity and solids meeting effluent disposal standards of these parameters considering the Federal and Minas Gerais State legislation, in Brazil, even in a transient phase of operation, at temperatures below 20°C. However, the effluents from the BAR can’t be released into water bodies without other parameters such as nitrogen, phosphorus, fecal coliforms, and others are investigated to be conforming to those standards.

  19. Sanitizing effects of sewage sludge irradiation treatment

    International Nuclear Information System (INIS)

    Zhao Yongfu

    2005-01-01

    A large quantity of pathogenic organisms were found in sewage sludge. An investigation was carried out on the relationship in the chain of sludge-soil-vegetable between the survival of pathogenic organisms and the irradiation dosage. After irradiation with 5-6 kGy, coliform group reduced 3 log cycles, and ascarid ova were completely eliminated with a dose of 1 kGy, making the water matched the standard quality of irrigating water. In the soil applied with irradiated sewage sludge, the total bacteria and coliforms group count reduced to one tenth, and alive ascarid ova was not detected. The coliform group on the Chinese cabbage was extremely low and reached the standard of fresh eating. (authors)

  20. Numerical convergence for a sewage disposal problem

    OpenAIRE

    Alvarez-Vázquez, L.J.; Martínez, A.; Rodríguez, C.; Vázquez-Méndez, M.E.

    2001-01-01

    The management of sewage disposal and the design of wastewater treatment systems can be formulated as a constrained pointwise optimal control problem. In this paper we study the convergence of the numerical resolution for the corresponding state system by means of a characteristics Galerkin method. The main difficulty of the problem is due to the existence of Radon measures in the right-hand side of the state system. Finally, we present numerical results for a realistic problem posed in a ria...

  1. Sustainability of Domestic Sewage Sludge Disposal

    OpenAIRE

    Claudia Bruna Rizzardini; Daniele Goi

    2014-01-01

    Activated sludge is now one of the most widely used biological processes for the treatment of wastewaters from medium to large populations. It produces high amounts of sewage sludge that can be managed and perceived in two main ways: as a waste it is discharged in landfill, as a fertilizer it is disposed in agriculture with direct application to soil or subjected to anaerobic digestion and composting. Other solutions, such as incineration or production of concrete, bricks and asphalt play a s...

  2. Virological investigations on inadiated sewage sludge

    International Nuclear Information System (INIS)

    Epp, C.

    1980-08-01

    The virusinactivating activity of a Co 60 -irradiation pilot plant at Geiselbullach/Munich was to be examined. We investigated 16 impure sewage water, 15 purified sewage water, 32 raw sladge samples, 62 digested sludge samples before irradiation, 52 digested sludge samples after irradiation and 9 raw sludge samples after irradiation. We completed these investigations by adding poliovaccinevirus type 1 to the digested sludge before irradiation and by adding suspensions of pure virus in MEM + 2% FBS packed in synthetic capsules and mixtures of virus and sludge packed in synthetic capsules to the digested sludge. After the irradiation we collected the capsules and determined the virustiter. The testviruses were poliovaccinevirus type 1, poliowildvirus type 1, echovirus type 6, coxsackie-B-virus type 5, coxsackie-A-virus type 9 and adenovirus type 1. In the field trial the irradiation results were like the laboratory results assuming that the sewage sludge was homogenized enough by digestion and the solid particle concentration was not more than 3%. The D-value was 300-400 krad for enteroviruses and 700 krad for adenovirus. (orig.) [de

  3. Electron beam disinfection of sewage sludge

    International Nuclear Information System (INIS)

    Hashimoto, Shoji

    1992-01-01

    Electron beam treatment of dehydrated sewage sludge for safe reutilization was performed. Ranges of total bacterial counts and total coliforms in the sludge were from 1.5 x 10 8 to 1.6 x 10 9 and from 2.2 x 10 7 to 1.5 x 10 8 per wet gram, respectively. Total bacterial counts decreased about 5 log cycles after irradiating 5 kGy and irradiation with 2 kGy was enough to kill all coliforms in sewage sludge. The survival curves of total bacteria, obtained by irradiation in oxygen atmosphere, approached to that in nitrogen atmosphere with the increase of sludge thickness. No effects of dose rate and electron energy were found when the sludge layers were thin enough. Continuous disinfection of sewage sludge cake, with the maximum feed rate of 300 kg-sludge/hr, was successfully performed with a Cockcroft-Walton type electron accelerator, a sludge pump and a flat nozzle. (J.P.N.)

  4. Sewage sludge as a biomass energy source

    Directory of Open Access Journals (Sweden)

    Pavel Kolat

    2013-01-01

    Full Text Available The major part of the dry matter content of sewage sludge consists of nontoxic organic compounds, in general a combination of primary sludge and secondary microbiological sludge. The sludge also contains a substantive amount of inorganic material and a small amount of toxic components. There are many sludge-management options in which production of energy is one of the key treatment steps. The most important options are anaerobic digestion, co-digestion, incineration in combination with energy recovery and co-incineration in coal-fired power plants. The goal of our applied research is to verify, if the sludge from waste water treatment plants may be used as a biomass energy source in respect of the EU legislation, which would comply with emission limits or the proposal of energy process optimizing the preparation of coal/sludge mixture for combustion in the existing fluid bed boilers in the Czech Republic. The paper discusses the questions of thermal usage of mechanically drained stabilized sewage sludge from the waste water treatment plants in the boiler with circulated fluid layer. The paper describes methods of thermal analysis of coal, sewage sludge and its mixtures, mud transport to the circulating fluidised bed boiler, effects on efficiency, operational reliability of the combustion equipment, emissions and solid combustion residues.

  5. Sewage sludge treatment, utilisation and disposal; Schlammbehandlung, -verwertung und -beseitigung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    In view of recent events and the resulting emotional and political decisions, the issue of sewage sludge treatment and disposal in Germany. must be seen in a new light. First, a new concept for sewage sludge management must be developed as recent legislation interferes with the 'classic' strategy of utilisation in agriculture, dumping and combustion. Scientists and sewage plant owners must find new ways to implement the specifications of the Act on Recycling and Waste Management. This ATV-DVWK training course discusses subjects that may be helpful on the new path. Starting from current legislation, problems, decision criteria and cost of sewage sludge treatment are gone into. Dimensioning fundamentals for sewage treatment plants re presented, and new and established treatment methods, operational problems and pollution problems are discussed. Further subjects are recycling of useful materials from sewage sludge, co-treatment of organic materials in fermenters, and disposal concepts for small and medium-sized communities. (orig.)

  6. Increased risk of hepatitis E in sewage workers from India.

    Science.gov (United States)

    Vaidya, Sunil R; Tilekar, Bipin N; Walimbe, Atul M; Arankalle, Vidya A

    2003-11-01

    Considering feco-oral transmission of hepatitis E virus (HEV), the risk of the infection was assessed among sewage workers. On the basis of the close contact with sewage, the participants (n = 147) were divided into sewage workers (n = 92) and others (n = 55); none used personal protective equipment (eg, coveralls, boots, gloves) Age-matched individuals from lower socioeconomic status and without any exposure to sewage were used as controls. IgG-anti-HEV positivity in enzyme-linked immunosorbent assay was significantly higher (P 5 years. Multivariate regression analysis identified contact with sewage as the independent variable associated with anti-HEV positivity. Strict adherence to good working practices must take top priority for protection of these workers from sewage pathogens.

  7. The exploitation of swamp plants for dewatering liquid sewage sludge

    Directory of Open Access Journals (Sweden)

    Jiří Šálek

    2006-01-01

    Full Text Available The operators of little rural wastewater treatment plants have been interested in economic exploitation of sewage sludge in local conditions. The chance is searching simply and natural ways of processing and exploitation stabilized sewage sludge in agriculture. Manure substrate have been obtained by composting waterless sewage sludge including rest plant biomass after closing 6–8 years period of filling liquid sewage sludge to the basin. Main attention was focused on exploitation of swamp plants for dewatering liquid sewage sludge and determination of influence sewage sludge on plants, intensity and course of evapotranspiration and design and setting of drying beds. On the base of determined ability of swamp plants evapotranspiration were edited suggestion solutions of design and operation sludge bed facilities in the conditions of small rural wastewater treatment plant.

  8. Biological nitrogen removal from sewage via anammox: Recent advances.

    Science.gov (United States)

    Ma, Bin; Wang, Shanyun; Cao, Shenbin; Miao, Yuanyuan; Jia, Fangxu; Du, Rui; Peng, Yongzhen

    2016-01-01

    Biological nitrogen removal from sewage via anammox is a promising and feasible technology to make sewage treatment energy-neutral or energy-positive. Good retention of anammox bacteria is the premise of achieving sewage treatment via anammox. Therefore the anammox metabolism and its factors were critically reviewed so as to form biofilm/granules for retaining anammox bacteria. A stable supply of nitrite for anammox bacteria is a real bottleneck for applying anammox in sewage treatment. Nitritation and partial-denitrification are two promising methods of offering nitrite. As such, the strategies for achieving nitritation in sewage treatment were summarized by reviewing the factors affecting nitrite oxidation bacteria growth. Meanwhile, the methods of achieving partial-denitrification have been developed through understanding the microorganisms related with nitrite accumulation and their factors. Furthermore, two cases of applying anammox in the mainstream sewage treatment plants were documented. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. MICROBIAL LOAD AND MULTIPLE DRUG RESISTANCE OF PATHOGENIC BACTERIA ISOLATED FROM FEACES AND BODY SURFACES OF COCKROACHES IN AN URBAN AREA OF SOUTHWESTERN NIGERIA

    Directory of Open Access Journals (Sweden)

    Monsuru Adebayo Adeleke

    2012-06-01

    Full Text Available This study investigates the microbial load and antibiotic susceptibility pattern of pathogenic bacteria isolated from the faeces and body surfaces of cockroaches in Osogbo, Southwestern Nigeria. The cockroaches collected from residential areas and hospital vicinities were screened for microbial load and antibiotic susceptibility pattern using standard protocols. A total of twenty- three microorganisms namely Klebsiella aerogenes, Bacillius cereus, Proteus spp, Staphyloccocus aureus, S. saprophyticus, Enteroccocus faecalis, Staphylococus epididermis, E. coli, Listeria monoctogene, Proteus mirabilis, Citrobacter species, Pseudomonas aeruginosa, Psuedomonas species, Seretia mensence, Candida albicans, Candida spp., Aspergilius spp., A. flavus, A. fumigates, Mucor species and Penicilium species were isolated. The microbial load of the microorganisms was significantly higher in the isolates from hospital as compared with the residential area (p<0.05 with the exception of Canidida species, Mucor and Penicillium which had higher or equal microbial load at the residential areas. All the pathogenic bacteria isolated had multiple resistance to antibiotics most importantly, Ampicillin, Augumentin, Amoxicillin and Septrin (30μg. Efforts geared towards controlling the insects will be indispensable in curbing the wide spread of multi-drug resistant pathogens in the study area.

  10. Analysis of the concentrations and fate of heavy metals and sewage in municipal sewage treatment systems

    International Nuclear Information System (INIS)

    Ried, A.

    1992-01-01

    The fate of selected substances during sewage treatment was investigated in the Marburg/Cappel sewage plant. The following parameters were measured: Concentrations of the metal ions of Cr, Cu, Pb, Cd, Fe, Ca and Zn; pH; conductivity; extinctions at 254 and 436 nm; phosphate, chloride and solids concentrations in the sample. Heavy metals (in solution and in bands) were eliminated in the following order: Cr(97%) > Pb(96%) > Cu(84%) > Zn(80%) > Ni(72%) > Cd(61%). Further, the effects of EDTA on the bonded and dissolved metal ions of iron(III), zinc(II), nickel(II) and copper(II) were investigated in a sewage sample. Resolution of bonded metals was observed only in the case of zinc. (orig.) [de

  11. Water Hyacinths and Alligator Weeds for Final Filtration of Sewage

    Science.gov (United States)

    Wolverton, B. C.; Mcdonald, R. C.; Gordon, J.

    1976-01-01

    The potential of water hyacinths (Eichhornia crassipes) (Mart.) Solms and alligator weeds (Alternanthera philoxerides) (Mart.) Griesb. as secondary and tertiary filtration systems for domestic sewage was demonstrated. These two vascular aquatic plants reduced the suspended solids, total Kjeldahl nitrogen, total phosphorus, BOD sub 5, and total organic carbon levels in domestic sewage from 60 percent to 98 percent within a two week period. These plants grown in domestic sewage were also free of toxic levels of trace heavy metals.

  12. REEMISSION OF MERCURY COMPOUNDS FROM SEWAGE SLUDGE DISPOSAL

    Directory of Open Access Journals (Sweden)

    Beata Janowska

    2016-12-01

    Full Text Available The sewage sludge disposal and cultivation methods consist in storage, agricultural use, compost production, biogas production or heat treatment. The sewage sludge production in municipal sewage sludge treatment plants in year 2013 in Poland amounted to 540.3 thousand Mg d.m. The sewage sludge for agricultural or natural use must satisfy chemical, sanitary and environmental safety requirements. The heavy metal content, including the mercury content, determines the sewage sludge disposal method. Mercury has a high chemical activity and biological form compounds with different properties. The properties of the mercury present in sewage sludge or composts, its potential bioavailability depend on its physicochemical forms. Different forms of mercury, which are found in soil and sediments and sewage sludge, may be determined using various techniques sequential extraction. In order to assess the bioavailability the analysis of fractional of mercury in samples of sewage sludge and composts was made. For this purpose the analytical procedure based on a four sequential extraction process was applied. Mercury fractions were classified as exchangeable (EX, base soluble (BS, acids soluble (AS and oxidizable (OX. This article presents the research results on the mercury compounds contents in sewage sludge subjected to drying process, combustion and in composted sewage sludge. During drying and combustion process of the sewage sludge, mercury transforms into volatile forms that could be emitted into the atmosphere. The mercury fractionation in composted sewage sludge proved that mercury in compost occurs mainly in an organic fraction and in a residual fraction that are scarce in the environment.

  13. Submersible microbial fuel cell for electricity production from sewage sludge

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Olias, Lola Gonzalez; Kongjan, Prawit

    2011-01-01

    A submersible microbial fuel cell (SMFC) was utilized to treat sewage sludge and simultaneously generate electricity. Stable power generation (145± 5 mW/m2, 470 Ω) was produced continuously from raw sewage sludge for 5.5 days. The maximum power density reached 190±5 mW/m2. The corresponding total...... system to treat sewage sludge and simultaneously recover energy....

  14. Mathematical experimental modeling for muffle furnace drying process of municipal sewage sludge in Beijing and Osaka

    International Nuclear Information System (INIS)

    Li, Xinyi; Takaoka, Masaki; Zhu, Fenfen; Oshita, Kazuyuki; Mizuno, Tadao; Morisawa, Shinsuke

    2010-01-01

    Over the past two decades, China has experienced rapid urbanization, which also leads to a lot of environmental problems including those of sewage sludge. As the amount of sewage sludge increases, conventional methods of treatment, such as compost and landfill, are facing the problems of limitations in demands or land. Considering that the demand of constructive materials in China keeps increasing, reusing municipal sewage sludge (MSS) in cement manufactory plant as fuels and raw materials is another practicable way to deal with it. The aim of this study is to describe the process of the heating of sewage sludge under different atmospheres of nitrogen and oxygen, and to find out some relation between the moisture of MSS and the heating time under different surrounding temperature by means of a mathematical model. In this study, we compared 4 kinds of MSS sampled in Beijing and Osaka. First of all, we defined the differences in those fundamental physical properties, such as concentration of various elements, calorific values and so on. Then the macroscopical thermal properties of the sludges were observed by means of thermogravimetric (TG) analysis. Both pyrolysis and combustion of 4 samples of MSS were studied by TG dynamic runs carried out at 10K/m. Visual observation of the heating profiles shows three stages in the heating process, which have been characterized. At last, we focused on batch processing drying tests using muffle furnace under temperature of 200, 250 and 300 degrees Celsius. The volatile matters loss besides moisture during heating process was evaluated and the experimental drying curves were matched with a mathematical model. (author)

  15. A critical review of the bioavailability and impacts of heavy metals in municipal solid waste composts compared to sewage sludge.

    Science.gov (United States)

    Smith, Stephen R

    2009-01-01

    The content, behaviour and significance of heavy metals in composted waste materials is important from two potentially conflicting aspects of environmental legislation in terms of: (a) defining end-of-waste criteria and increasing recycling of composted residuals on land and (b) protecting soil quality by preventing contamination. This review examines the effects of heavy metals in compost and amended soil as a basis for achieving a practical and sustainable balance between these different policy objectives, with particular emphasis on agricultural application. All types of municipal solid waste (MSW) compost contain more heavy metals than the background concentrations present in soil and will increase their contents in amended soil. Total concentrations of heavy metals in source-segregated and greenwaste compost are typically below UK PAS100 limits and mechanical segregated material can also comply with the metal limits in UK PAS100, although this is likely to be more challenging. Zinc and Pb are numerically the elements present in the largest amounts in MSW-compost. Lead is the most limiting element to use of mechanically-segregated compost in domestic gardens, but concentrations are typically below risk-based thresholds that protect human health. Composted residuals derived from MSW and greenwaste have a high affinity for binding heavy metals. There is general consensus in the scientific literature that aerobic composting processes increase the complexation of heavy metals in organic waste residuals, and that metals are strongly bound to the compost matrix and organic matter, limiting their solubility and potential bioavailability in soil. Lead is the most strongly bound element and Ni the weakest, with Zn, Cu and Cd showing intermediate sorption characteristics. The strong metal sorption properties of compost produced from MSW or sewage sludge have important benefits for the remediation of metal contaminated industrial and urban soils. Compost and sewage sludge

  16. Sewage pollution: mitigation is key for coral reef stewardship.

    Science.gov (United States)

    Wear, Stephanie L; Thurber, Rebecca Vega

    2015-10-01

    Coral reefs are in decline worldwide, and land-derived sources of pollution, including sewage, are a major force driving that deterioration. This review presents evidence that sewage discharge occurs in waters surrounding at least 104 of 112 reef geographies. Studies often refer to sewage as a single stressor. However, we show that it is more accurately characterized as a multiple stressor. Many of the individual agents found within sewage, specifically freshwater, inorganic nutrients, pathogens, endocrine disrupters, suspended solids, sediments, and heavy metals, can severely impair coral growth and/or reproduction. These components of sewage may interact with each other to create as-yet poorly understood synergisms (e.g., nutrients facilitate pathogen growth), and escalate impacts of other, non-sewage-based stressors. Surprisingly few published studies have examined impacts of sewage in the field, but those that have suggest negative effects on coral reefs. Because sewage discharge proximal to sensitive coral reefs is widespread across the tropics, it is imperative for coral reef-focused institutions to increase investment in threat-abatement strategies for mitigating sewage pollution. © 2015 The Authors. Annals of the New York Academy of Sciences published by Wiley Periodicals Inc. on behalf of The New York Academy of Sciences.

  17. Wekiva Basin onsite sewage treatment and disposal system study

    OpenAIRE

    Booher, Paul

    2006-01-01

    Existing onsite systems and aquifer vulnerability in the Wekiva Basin. Recommendations from the Bureau of Onsite Sewage Programs, Division of Environmental Health, Florida Department of Health. (11 slides)

  18. Biogeochemistry and community ecology in a spring-fed urban river following a major earthquake.

    Science.gov (United States)

    Wells, Naomi S; Clough, Tim J; Condron, Leo M; Baisden, W Troy; Harding, Jon S; Dong, Y; Lewis, G D; Lear, Gavin

    2013-11-01

    In February 2011 a MW 6.3 earthquake in Christchurch, New Zealand inundated urban waterways with sediment from liquefaction and triggered sewage spills. The impacts of, and recovery from, this natural disaster on the stream biogeochemistry and biology were assessed over six months along a longitudinal impact gradient in an urban river. The impact of liquefaction was masked by earthquake triggered sewage spills (~20,000 m(3) day(-1) entering the river for one month). Within 10 days of the earthquake dissolved oxygen in the lowest reaches was urban natural disasters. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Towards sustainable urban water governance in Denmark: collective building of capabilities in local authorities

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Jensen, Marina Bergen

    2016-01-01

    be achieved. The ‘urban water platform’ was tested and is hereby presented as a course concept for building collective capabilities for integrated sustainable water design among local authorities in Denmark. The course is an innovation because: 1) it invites urban planners, road and park managers and sewage...

  20. Sewage pollution: genotoxicity assessment and phytoremediation of nutrients excess with Hydrocotyle ranunculoides.

    Science.gov (United States)

    Basílico, Gabriel; Magdaleno, Anahí; Paz, Marta; Moretton, Juan; Faggi, Ana; de Cabo, Laura

    2017-04-01

    The discharge of sewage effluents into low-order streams has negative effects on water quality. Macrophytes can be efficient in the treatment of this wastewater due to the removal of the main pollutants. The genotoxicity of sewage-polluted water discharging into La Choza stream was evaluated by testing with Allium cepa. Also, a phytoremediation assay with continuous recirculation of the residual water was conducted for 12 days. Three treatments were carried out. One treatment (Hr) was performed with a macrophyte (Hydrocotyle ranunculoides), and two treatments were conducted without macrophytes: with lighting (Ai) and without lighting (Ao). The wastewater was toxic according to all the evaluated indexes (mitotic index, frequency of chromosomal aberrations and micronucleus). High concentrations of ammonium, dissolved inorganic nitrogen (DIN), total (TP) and soluble reactive phosphorous (SRP) and indicators of faecal contamination were determined in the wastewater. The ammonium, DIN, SRP and TP loads at the end of the assay were significantly lower in the treatments with light (Hr and Ai). So, the nutrient removal was due to their absorption and adsorption by the periphyton and H. ranunculoides. Our results lead us to recommend the maintenance and planting of macrophytes in lowland streams subject to sewage pollution.

  1. Integration of the management of urban solid residues and muds: a symbiotic solution; Integracion de la gestion de residuos solidos urbanos y lodos: una solucion simbiotica

    Energy Technology Data Exchange (ETDEWEB)

    McCarty, T.; Mulder, M.; Van Berlo, M.

    2008-07-01

    Linking a sewage treatment plant and a waste-to-energy plant brings energy efficiency benefits to both. The combined plant minimizes environmental impact and maximizes energy production, putting Amsterdam at the forefront of urban waste management. (Author)

  2. Economic and environmental sustainability of submerged anaerobic MBR-based (AnMBR-based) technology as compared to aerobic-based technologies for moderate-/high-loaded urban wastewater treatment.

    Science.gov (United States)

    Pretel, R; Robles, A; Ruano, M V; Seco, A; Ferrer, J

    2016-01-15

    The objective of this study was to assess the economic and environmental sustainability of submerged anaerobic membrane bioreactors (AnMBRs) in comparison with aerobic-based technologies for moderate-/high-loaded urban wastewater (UWW) treatment. To this aim, a combined approach of steady-state performance modelling, life cycle analysis (LCA) and life cycle costing (LCC) was used, in which AnMBR (coupled with an aerobic-based post-treatment) was compared to aerobic membrane bioreactor (AeMBR) and conventional activated sludge (CAS). AnMBR with CAS-based post-treatment for nutrient removal was identified as a sustainable option for moderate-/high-loaded UWW treatment: low energy consumption and reduced sludge production could be obtained at given operating conditions. In addition, significant reductions can be achieved in different aspects of environmental impact (global warming potential (GWP), abiotic depletion, acidification, etc.) and LCC over existing UWW treatment technologies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Experimental Study on the Treatment of low C/N ratio disposal of sewage with BAF

    Science.gov (United States)

    Wang, W. J.; Ma, T.; Cheng, W.

    2010-03-01

    The Biological Aerated Filter (BAF) is a simple, high-efficient, low-consumptive for new biological membrane method correspond to the situation of china, will be one of the main technical measures to solve the progressive deterioration of water environment problem faced china especially medium and small towns. This paper focuses on the experimental study and mechanism analysis in which the up flow, cocurrent gas-water, single-stage BAF was adopted on treatment domestic wastewater, the results showed that BAF has good performance in treating domestic sewage, and it had steady treatment effect with different pollution loads.

  4. Distributed models coupling soakaways, urban drainage and groundwater

    DEFF Research Database (Denmark)

    Roldin, Maria Kerstin

    in receiving waters, urban flooding etc. WSUD structures are generally small, decentralized systems intended to manage stormwater near the source. Many of these alternative techniques are based on infiltration which can affect both the urban sewer system and urban groundwater levels if widely implemented......Alternative methods for stormwater management in urban areas, also called Water Sensitive Urban Design (WSUD) methods, have become increasingly important for the mitigation of urban stormwater management problems such as high runoff volumes, combined sewage overflows, poor water quality......, and how these can be modeled in an integrated environment with distributed urban drainage and groundwater flow models. The thesis: 1. Identifies appropriate models of soakaways for use in an integrated and distributed urban water and groundwater modeling system 2. Develops a modeling concept that is able...

  5. Sewage sludge irradiators: Batch and continuous flow

    International Nuclear Information System (INIS)

    Lavale, D.S.; George, J.R.; Shah, M.R.; Rawat, K.P.

    1998-01-01

    The potential threat to the environment imposed by high pathogenic organism content in municipal wastewater, especially the sludge and the world-wide growing aspirations for a cleaner, salubrious environment have made it mandatory for the sewage and sludge to undergo treatment, prior to their ultimate disposal to mother nature. Incapabilities associated with the conventional wastewater treatments to mitigate the problem of microorganisms have made it necessary to look for other alternatives, radiation treatment being the most reliable, rapid and environmentally sustainable of them. To promote the use of radiation for the sludge hygienization, Department of Atomic Energy has endeavoured to set up an indigenous, Sludge Hygienization Research Irradiator (SHRI) in the city of Baroda. Designed for 18.5 PBq of 60 Co to disinfect the digested sludge, the irradiator has additional provision for treatment of effluent and raw sewage. From engineering standpoint, all the subsystems have been functioning satisfactorily since its commissioning in 1990. Prolonged studies, spanning over a period of six years, primarily focused on inactivation of microorganism revealed that 3 kGy dose of gamma radiation is adequate to make the sludge pathogen and odour-free. A dose of 1.6 kGy in raw sewage and 0.5 kGy in effluent reduced coliform counts down to the regulatory discharge limits. These observations reflect a possible cost-effective solution to the burgeoning problem of surface water pollution across the globe. In the past, sub 37 PBq 60 Co batch irradiators have been designed and commissioned successfully for the treatment of sludge. Characterized with low dose delivery rates they are well-suited for treating low volumes of sludge in batches. Some concepts of continuous flow 60 Co irradiators having larger activities, yet simple and economic in design, are presented in the paper

  6. Oil and coal from sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    Naumann, H

    1981-01-01

    Under the leadership of professor Ernst Bayer a research group of Tuebingen succeeded in producing oil and coal from sewage sludge. The conversion of biomass into fossil fuels which in nature can only be calculated in historical periods of time is here brought about by the use of a catalyst on the basis of silicate and aluminium oxide, dopened with copper. First breakeven evaluations have given a real chance to be able to operate economically in a large scale plant the process being developed in laboratory tests.

  7. Adapting UASB technology for sewage treatment in Palestine and Jordan

    NARCIS (Netherlands)

    Mahmoud, N.A.; Zeeman, G.; Lier, van J.B.

    2008-01-01

    High rate anaerobic technologies offer cost-effective solutions for "sewage" treatment in the temperate climate of Palestine and Jordan. However, local sewage characteristics demand amendments to the conventional UASB reactor design. A solution is found in a parallel operating digester unit that

  8. Vancomycin resistant enterococci (VRE in Swedish sewage sludge

    Directory of Open Access Journals (Sweden)

    Aspan Anna

    2009-05-01

    Full Text Available Abstract Background Antimicrobial resistance is a serious threat in veterinary medicine and human healthcare. Resistance genes can spread from animals, through the food-chain, and back to humans. Sewage sludge may act as the link back from humans to animals. The main aims of this study were to investigate the occurrence of vancomycin resistant enterococci (VRE in treated sewage sludge, in a Swedish waste water treatment plant (WWTP, and to compare VRE isolates from sewage sludge with isolates from humans and chickens. Methods During a four month long study, sewage sludge was collected weekly and cultured for VRE. The VRE isolates from sewage sludge were analysed and compared to each other and to human and chicken VRE isolates by biochemical typing (PhenePlate, PFGE and antibiograms. Results Biochemical typing (PhenePlate-FS and pulsed field gel electrophoresis (PFGE revealed prevalence of specific VRE strains in sewage sludge for up to 16 weeks. No connection was found between the VRE strains isolated from sludge, chickens and humans, indicating that human VRE did not originate from Swedish chicken. Conclusion This study demonstrated widespread occurrence of VRE in sewage sludge in the studied WWTP. This implies a risk of antimicrobial resistance being spread to new farms and to the society via the environment if the sewage sludge is used on arable land.

  9. Modeling of Seepage Losses in Sewage Sludge Drying Bed ...

    African Journals Online (AJOL)

    This research was carried out to develop a model governing seepage losses in sewage sludge drying bed. The model will assist in the design of sludge drying beds for effective management of wastes derived from households' septic systems. In the experiment conducted this study, 125kg of sewage sludge, 90.7% moisture ...

  10. Arthropod fauna of the University of Nigeria, Nsukka, Sewage pond ...

    African Journals Online (AJOL)

    A survey of arthropod fauna of the University of Nigeria Nsukka sewage pond was carried out within May and June 2011. The aim was to determine the various arthropod species and its abundance in the sewage pond. The analysis was carried out by two methods, physico-chemical analysis and arthropod faunal studies.

  11. Anaerobic biodegradability and treatment of Egyption domestic sewage

    NARCIS (Netherlands)

    Elmitwally, T.A.; Al-Sarawey, A.; El-Sherbiny, M.F.; Zeeman, G.; Lettinga, G.

    2003-01-01

    The anaerobic biodegradability of domestic sewage for four Egyptian villages and four Egyptian cities was determined in batch experiments. The results showed that the biodegradability of the Egyptian-villages sewage (73%) was higher than that of the cities (66%). The higher biodegradability of the

  12. Development of sewage system for mega-city Karachi

    International Nuclear Information System (INIS)

    Talat, B.; Ahsan-Ullah

    2005-01-01

    The growth of mega-cities in recent times has brought to the fore a large number of issues with respect environmental conditions such as development of slum areas, poor localities, solid waste disposal, management of sewage system, lack of open spaces and health facilities. One of the major issues effecting environment proper disposal of sewage and development of sewage system including recycling of sewage water and its use. The heavy pressure of population calls for adequate provision of sewage disposal in the new areas and remodeling of systems in the old areas of the cities to ensure a pollution-free environment. Recycling of sewage and prevention of sewage discharge into natural water channels and the sea has to be undertaken on urgent bases. The paper seeks to outline the present status of sewage system of the city of Karachi, the problems involved and the proposals for management and development of the system compatible with the need and requirement of mega-city population. (author)

  13. Dosimetry report for the Sandia irradiator for dried sewage solids

    International Nuclear Information System (INIS)

    Greene, R.T.; McFarland, E.W.; Dickson, H.W.

    1981-06-01

    Gamma dose measurements were made at the Sandia Irradiator for Dried Sewage Solids. Passive plastic, chemical, and thermoluminescent dosimeters were exposed in the facility under conditions designed to simulate typical plant operation. Absolute dose and dose distribution information were obtained in air, water, compost, fruit, and sewage sludge

  14. Integral urban wastewater treatment process with a combined anaerobic and aerobic system; Tratamiento integral de aguas residuales urbanas mediante procesos combinados anaerobios y aerobios. Aplicacion de sistema Bioredox a escala piloto

    Energy Technology Data Exchange (ETDEWEB)

    Moreno Carmona, A; Angulo Sanchez, R.

    1997-04-01

    A pilot study was carried out of an integral urban sewage treatment process involving a combined anaerobic and aerobic system. the anaerobic digester has a fixed bed on a ceramic support and a 10m``3 upward flow. It operates at ambient temperature (12-15 degree centigree) with hydraulic retention to,es (HRTs) of 24-12 hours and a load of 4-2.6 kg DQO/m``3/day. Anaerobic digestion reduced SSt by over 90% for HRT of 16 and 12 hours. The 20 m``3 prolonged oxidation reactor operates with a load of 0.17-0.45 kg DQO/m``3/day. the plant`s DQO and SST reduction varied between 81% and 89% for the 16 and 12 hour tests and 85-92% (HRT=16 hours and 12 hours respectively). the overall proportions of pathogenic microorganisms eliminated in the experimental plant was greater than 97%. (Author) 23 refs.

  15. Irradiated sewage sludge for application to cropland. Results of a co-ordinated research project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-01

    Modern urban societies produce large volumes of sewage, which are transported through a network of underground sewers to wastewater treatment plants, where one or more stages of physical, biological and chemical treatment are imposed. Considerable tonnages of aerobically, and sometimes anaerobically, digested sludge are produced, and treated or untreated effluent is discharged to lagoons, waterways or the ocean. The disposal of sewage sludge is a major issue for municipal authorities. There are increasing legislative restrictions in many countries on disposal methods (e.g. incineration, landfill, composting) including surface application to agricultural land. Sludge can either be viewed as a dangerous waste requiring expensive disposal procedures, or it can be seen as a resource for possible use in agriculture as a soil conditioning agent and a source of plant nutrients. Untreated sewage sludge presents a public-health hazard as it contains human pathogens, including bacteria, viruses and other harmful organisms. Although it has been demonstrated that an appropriate dose of gamma-irradiation can eliminate human parasites and bacterial pathogens from sewage sludge, there is still public concern about the presence of viruses, as well as heavy metals and toxic organic compounds from industrial sources that could enter the food chain if sludge is applied to croplands. More information is also needed on the value of sludge as a source of plant nutrients, expressed in terms of fertilizer equivalence. In this regard, isotopic labelling techniques have a unique role to play in estimating the contribution of sewage sludge to crop nutrition. As a result of recommendations formulated at a Consultants Meeting organized by the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture and the IAEA Division of Physical and Chemical Sciences, 5-9 December 1994 (IAEA-TECDOC-971, Sewage Sludge and Wastewater for Use in Agriculture) the Joint Division implemented a Co

  16. OPERATION OF THE HOUSEHOLD SEWAGE TREATMENT PLANTS IN POLAND

    Directory of Open Access Journals (Sweden)

    Marcelina Pryszcz

    2015-01-01

    Full Text Available In many rural communities the building of sewage collection and treatment system is still current and important problem of water and wastewater management. Besides the collection of sewage in the septic tank, the solution for wastewater treatment from individual buildings without access to sewerage system is the construction of household sewage treatment plants. Construction of household sewage treatment plant poses a number of challenges for municipalities and potential investors. The existing plants should be analyzed, so that in the future the selected systems would be characterized by high performance, simple operation and reliable exploitation. In the paper, the assessment of selection criteria of adopted technical solution and the functioning of household sewage treatment plants is carried out.

  17. Combustion of Sewage Sludge as Alternative Fuel for Cement Industry

    Institute of Scientific and Technical Information of China (English)

    LI Fuzhou; ZHANG Wei

    2011-01-01

    The combustion of sewage sludge and coal was studied by thermogravimetric analysis.Both differential scanning calorimetric analysis and derivative thermogravimetric profiles showed differences between combustion of sewage sludge and coal, and non-isothermal kinetics analysis method was applied to evaluate the combustion process. Based on Coats-Redfem integral method, some reaction models were tested,the mechanism and kinetics of the combustion reaction were discussed. The results show that the combustion of sewage sludge is mainly in the Iow temperature stage, meanwhile the ignition temperature and Arrhenius activation energy are lower than that of coal. The combustion of sewage sludge has the advantage over coal in some aspects, thus sewage sludge can partly replace coal used as cement industry fuel.

  18. The effect of bioleaching on sewage sludge pyrolysis.

    Science.gov (United States)

    Chen, Zhihua; Hu, Mian; Cui, Baihui; Liu, Shiming; Guo, Dabin; Xiao, Bo

    2016-02-01

    The effects of bioleaching on sewage sludge pyrolysis were studied. Sewage sludge was treated by bioleaching with solid concentrations of 6% (w/v), 8% (w/v), 10% (w/v). Results showed that bioleaching treatment could modify the physicochemical properties of sewage sludge and enhance the metals removal. The optimum removal efficiencies of heavy metals were achieved with solid concentration of 6% (w/v) bioleaching treatment: Cu, 73.08%; Zn, 78.67%; Pb, 24.65%; Cd, 79.46%. The characterization results of thermogravimetric analysis (TGA) showed that the bioleached sewage sludge with a 6% (w/v) solid concentration treatment was the easiest to decompose. Pyrolytic experiments of bioleached sewage sludge were performed in a laboratory-scale fixed bed reactor. Results indicated that bioleaching treatment greatly influenced the product yields and gas composition. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Sewage sludge - What can be done with it?

    International Nuclear Information System (INIS)

    Beurer, P.; Geering, F.

    2002-01-01

    This article presents a review of the state-of-the-art in the disposal of the sewage sludge that is left over after treatment of wastewater. Also, developments over the past ten years both in market structures and in legislation are discussed and future developments are reviewed. On account of legislation and political influences on the market, the thermal exploitation of sewage sludge is looked at in depth. The ecological and economic aspects of sewage sludge disposal are examined and the costs of different methods of sewage sludge treatment are compared. Various methods of disposal including dumping, composting, incineration in cement ovens, coal-fired power stations and waste incineration facilities are discussed, as is burning in special sludge incineration plant. A prognosis is made on the development of sewage sludge quantities for Germany, Switzerland and Austria over the next years

  20. Monitoring anthropogenic sewage pollution on mangrove creeks in southern Mozambique: A test of Palaemon concinnus Dana, 1852 (Palaemonidae) as a biological indicator

    International Nuclear Information System (INIS)

    Penha-Lopes, Gil; Torres, Paulo; Cannicci, Stefano; Narciso, Luis; Paula, Jose

    2011-01-01

    Tropical coastal ecosystems, such as mangroves, have a great ecological and socioeconomic importance for adjacent systems and local populations, but intensive environmental impact monitoring is still lacking, mainly in East Africa. This study evaluated the potential anthropogenic disturbance on Palaemon concinnus population structure and fitness. Palaemon concinnus populations from one peri-urban (domestic sewage impacted) and two pristine mangrove creeks were studied by sampling nearly 100 shrimps per location every 15 days for 12 months. The shrimps at the peri-urban location were larger, experienced longer reproductive periods, presented higher proportion of ovigerous females and better embryo quality when compared with shrimps inhabiting pristine locations. Physiological indices (RNA/DNA ratio) were similar between shrimps at pristine and peri-urban mangroves. However, a higher level of parasitation by a Bopyridae isopod, Pseudione elongata indicated some degree of stress on the host at the peri-urban mangrove, with potential effects on the host population dynamics. -Research highlights: → Domestic sewage discharges at low concentrations increase fauna mangrove population parameters, due to the nutrient limitations. → Shrimps in the peri-urban mangrove location were larger, had longer reproductive periods, higher ovigerous females proportions and better embryo. → Physiological indice analysis (RNA/DNA ratio) between pristine and peri-urban mangroves. → Within the peri-urban mangrove, high levels of parasitation by Pseudionee longata caused stress and potential effects on the host population dynamics. → The effects of sewage on P. concinnus population increased the choice of possible bioindicators in East African coastal water. - The identification of the effects of the peri-urban conditions on P. concinnus increases the choice of possible bioindicators in East African coastal waters.

  1. Monitoring anthropogenic sewage pollution on mangrove creeks in southern Mozambique: A test of Palaemon concinnus Dana, 1852 (Palaemonidae) as a biological indicator

    Energy Technology Data Exchange (ETDEWEB)

    Penha-Lopes, Gil, E-mail: gil.penha-lopes@fc.ul.p [Laboratorio Maritimo da Guia, Centro de Oceanografia, FCUL, Avenida Na Senhora do Cabo, No 939, 2750-374 Cascais (Portugal); Institute of Biology, University of Southern Denmark, DK-5230 Odense M (Denmark); Torres, Paulo, E-mail: biol.paulo@gmail.co [Laboratorio Maritimo da Guia, Centro de Oceanografia, FCUL, Avenida Na Senhora do Cabo, No 939, 2750-374 Cascais (Portugal); Cannicci, Stefano, E-mail: stefano.cannicci@unifi.i [Dipartimento di Biologia Evoluzionistica, Universita degli Studi di Firenze, via Romana 17, I-50125 Firenze (Italy); Narciso, Luis, E-mail: lfnarciso@fc.ul.p [Laboratorio Maritimo da Guia, Centro de Oceanografia, FCUL, Avenida Na Senhora do Cabo, No 939, 2750-374 Cascais (Portugal); Paula, Jose, E-mail: jppaula@fc.ul.p [Laboratorio Maritimo da Guia, Centro de Oceanografia, FCUL, Avenida Na Senhora do Cabo, No 939, 2750-374 Cascais (Portugal)

    2011-02-15

    Tropical coastal ecosystems, such as mangroves, have a great ecological and socioeconomic importance for adjacent systems and local populations, but intensive environmental impact monitoring is still lacking, mainly in East Africa. This study evaluated the potential anthropogenic disturbance on Palaemon concinnus population structure and fitness. Palaemon concinnus populations from one peri-urban (domestic sewage impacted) and two pristine mangrove creeks were studied by sampling nearly 100 shrimps per location every 15 days for 12 months. The shrimps at the peri-urban location were larger, experienced longer reproductive periods, presented higher proportion of ovigerous females and better embryo quality when compared with shrimps inhabiting pristine locations. Physiological indices (RNA/DNA ratio) were similar between shrimps at pristine and peri-urban mangroves. However, a higher level of parasitation by a Bopyridae isopod, Pseudione elongata indicated some degree of stress on the host at the peri-urban mangrove, with potential effects on the host population dynamics. -Research highlights: Domestic sewage discharges at low concentrations increase fauna mangrove population parameters, due to the nutrient limitations. Shrimps in the peri-urban mangrove location were larger, had longer reproductive periods, higher ovigerous females proportions and better embryo. Physiological indice analysis (RNA/DNA ratio) between pristine and peri-urban mangroves. Within the peri-urban mangrove, high levels of parasitation by Pseudionee longata caused stress and potential effects on the host population dynamics. The effects of sewage on P. concinnus population increased the choice of possible bioindicators in East African coastal water. - The identification of the effects of the peri-urban conditions on P. concinnus increases the choice of possible bioindicators in East African coastal waters.

  2. Trail Creek II: Modeling Flow and E. Coli Concentrations in a Small Urban Stream using SWAT

    Science.gov (United States)

    Radcliffe, D. E.; Saintil, T.

    2017-12-01

    Pathogens are one of the leading causes of stream and river impairment in the State of Georgia. The common presence of fecal bacteria is driven by several factors including rapid population growth stressing pre-existing and ageing infrastructure, urbanization and poor planning, increase percent imperviousness, urban runoff, municipal discharges, sewage, pet/wildlife waste and leaky septic tanks. The Trail Creek watershed, located in Athens-Clarke County, Georgia covers about 33 km2. Stream segments within Trail Creek violate the GA standard due to high levels of fecal coliform bacteria. In this study, the Soil and Water Assessment Tool (SWAT) modeling software was used to predict E. coli bacteria concentrations during baseflow and stormflow. Census data from the county was used for human and animal population estimates and the Fecal Indicator Tool to generate the number of colony forming units of E. Coli for each source. The model was calibrated at a daily time step with one year of monitored streamflow and E. coli bacteria data using SWAT-CUP and the SUFI2 algorithm. To simulate leaking sewer lines, we added point sources in the five subbasins in the SWAT model with the greatest length of sewer line within 50 m of the stream. The flow in the point sources were set to 5% of the stream flow and the bacteria count set to that of raw sewage (30,000 cfu/100 mL). The calibrated model showed that the average load during 2003-2013 at the watershed outlet was 13 million cfu per month. Using the calibrated model, we simulated scenarios that assumed leaking sewers were repaired in one of the five subbasins with point sources. The reduction ranged from 10 to 46%, with the largest reduction in subbasin in the downtown area. Future modeling work will focus on the use of green infrastructure to address sources of bacteria.

  3. Vitrification as an alternative to landfilling of tannery sewage sludge.

    Science.gov (United States)

    Celary, Piotr; Sobik-Szołtysek, Jolanta

    2014-12-01

    Due to high content of heavy metals such as chromium, tannery sewage sludge is a material which is difficult to be biologically treated as it is in the case of organic waste. Consequently, a common practice in managing tannery sewage sludge is landfilling. This poses a potential threat to both soil and water environments and it additionally generates costs of construction of landfills that meet specific environment protection requirements. Vitrification of this kind of sewage sludge with the addition of mineral wastes can represent an alternative to landfilling. The aim of this study was to investigate the possibility of obtaining an environmentally safe product by means of vitrification of tannery sewage sludge from a flotation wastewater treatment process and chemical precipitation in order to address the upcoming issue of dealing with sewage sludge from the tannery industry which will be prohibited to be landfilled in Poland after 2016. The focus was set on determining mixtures of tannery sewage sludge with additives which would result in the lowest possible heavy metal leaching levels and highest hardness rating of the products obtained from their vitrification. The plasma vitrification process was carried out for mixtures with various amounts of additives depending on the type of sewage sludge used. Only the materials of waste character were used as additives. One finding of the study was an optimum content of mineral additives in vitrified mixture of 30% v/v waste molding sands with 20% v/v carbonate flotation waste from the zinc and lead industry for the formulations with flotation sewage sludge, and 45% v/v and 5% v/v, respectively, for precipitation sewage sludge. These combinations allowed for obtaining products with negligible heavy metal leaching levels and hardness similar to commercial glass, which suggests they could be potentially used as construction aggregate substitutes. Incineration of sewage sludge before the vitrification process lead to

  4. Cesium and strontium loads into a combined sewer system from rainwater runoff.

    Science.gov (United States)

    Kamei-Ishikawa, Nao; Yoshida, Daiki; Ito, Ayumi; Umita, Teruyuki

    2016-12-01

    In this study, combined sewage samples were taken with time in several rain events and sanitary sewage samples were taken with time in dry weather to calculate Cs and Sr loads to sewers from rainwater runoff. Cs and Sr in rainwater were present as particulate forms at first flush and the particulate Cs and Sr were mainly bound with inorganic suspended solids such as clay minerals in combined sewage samples. In addition, multiple linear regression analysis showed Cs and Sr loads from rainwater runoff could be estimated by the total amount of rainfall and antecedent dry weather days. The variation of the Sr load from rainwater to sewers was more sensitive to total amount of rainfall and antecedent dry weather days than that of the Cs load. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Urban solid waste in the production of Lafoensia pacari seedlings

    Directory of Open Access Journals (Sweden)

    Alan H. M. de Abreu

    Full Text Available ABSTRACT This study aimed to verify the potential of urban solid wastes as substrate for production of seedlings of Lafoensia pacari. Five treatments were tested, four with solid wastes and one standard substrate, namely: sewage sludge from Alegria Wastewater Treatment Plant (WTP; sewage sludge from Ilha do Governador WTP; sewage sludge from Sarapuí WTP; domestic garbage compost (Fertlurb; and a commercial substrate made of biostabilized pine bark (standard substrate. The wastes received 20% (in volume of shredded coconut fiber. At 105 days after sowing, the seedlings were evaluated for different quality parameters. Seedlings produced with Sarapuí WTP sewage sludge showed the best results in all the parameters, followed by seedlings produced with sewage sludge from Alegria and Ilha do Governador WTPs, which did not differ. Seedlings produced with domestic garbage compost showed satisfactory results, higher than the ones observed for seedlings produced with commercial substrate. The urban solid wastes with 20% of coconut fiber showed high potential and can be recommended for the composition of substrate in the production of Lafoensia pacari seedlings.

  6. Sludge, garbage may fuel California sewage plant

    Energy Technology Data Exchange (ETDEWEB)

    Sieger, R B

    1977-01-01

    The combustion and pyrolysis of sewage sludge and refuse-derived fuel (RFD) in multiple-hearth furnaces were recommended as a means of generating energy to power the Central Contra Costa Sanitary District's 30 mgd wastewater treatment plant using an off-gas from the pyrolysis process. In a full-scale test, a furnace in Concord, once used for sewage sludge incineration, was operated under O/sub 2/-starved conditions by limiting air addition through the burners and air nozzles, resulting in partial combustion. Using temperature as the controlled variable, the process was regulated to form a fuel gas through composition of the organic feed matter. Just enough fuel gas was combusted to evaporate moisture in the feed solids and furnish heat for the decomposition process. During most of the testing the afterburner was maintained at a temperature > 1400/sup 0/F with pyrolysis gas. At this temperature, automatic ignition of the gas occurred. When the gas generated dropped to a low heat of combustion because of high feed moisture content, the afterburner burner was used to ignite the gas. Some test observations are discussed. Preparation of the solid waste for processing by the use of shredders, air classifiers, and magnetic separators is described.

  7. Atmospheric Inputs of Nitrogen, Carbon, and Phosphorus across an Urban Area: Unaccounted Fluxes and Canopy Influences

    Science.gov (United States)

    Decina, Stephen M.; Templer, Pamela H.; Hutyra, Lucy R.

    2018-02-01

    Rates of atmospheric deposition are declining across the United States, yet urban areas remain hotspots of atmospheric deposition. While past studies show elevated rates of inorganic nitrogen (N) deposition in cities, less is known about atmospheric inputs of organic N, organic carbon (C), and organic and inorganic phosphorus (P), all of which can affect ecosystem processes, water quality, and air quality. Further, the effect of the tree canopy on amounts and forms of nutrients reaching urban ground surfaces is not well-characterized. We measured growing season rates of total N, organic C, and total P in bulk atmospheric inputs, throughfall, and soil solution around the greater Boston area. We found that organic N constitutes a third of total N inputs, organic C inputs are comparable to rural inputs, and inorganic P inputs are 1.2 times higher than those in sewage effluent. Atmospheric inputs are enhanced two-to-eight times in late spring and are elevated beneath tree canopies, suggesting that trees augment atmospheric inputs to ground surfaces. Additionally, throughfall inputs may directly enter runoff when trees extend above impervious surfaces, as is the case with 26.1% of Boston's tree canopy. Our results indicate that the urban atmosphere is a significant source of elemental inputs that may impact urban ecosystems and efforts to improve water quality, particularly in terms of P. Further, as cities create policies encouraging tree planting to provide ecosystem services, locating trees above permeable surfaces to reduce runoff nutrient loads may be essential to managing urban biogeochemical cycling and water quality.

  8. Intensification of sewage treatment processes from harmful substances

    International Nuclear Information System (INIS)

    Asadov, S.M.

    2007-01-01

    Full text: Intensive development of power, chemical, oil, machine-building and other industries results in increase of industrial toxic emissions. Local pollutions as a result of emissions of the industrial enterprises in many cases surpass the maximum permissible sanitary norms. E.g. works connected to an oil recovery, have led to pollution of huge territories of the Azerbaijan Republic, including Caspian Sea. Development of scientific bases of optimization of operating practices of industrial sewage treatment will allow to liquidate the harmful impurities. It is necessary for preservation of the environment to increase the clearing and sewage quality degree. During modeling a real process of sewage treatment from polluting impurities we need to build more and more complex models. It demands in return the application of applied mathematics methods for process of clearing of liquids. General theory and technology of sewage treatment, in particular, from heavy metals, radioactive nuclides now are absent. Achievement of an object provides for solution of the following problems: a) Research of laws of influence of various technological and physical and chemical parameters on efficiency of waste treatment from heavy metals and radioactive nuclides; b) Development of the effective reagents, allowing to remove from sewage cations of toxic heavy metals and radioactive nuclides; c) Construction of statistical models of an experimental material on clearing concrete sewage; d) Modeling of searches of optimum modes of sewage treatment processes from heavy metals ions; e) Development of optimum processes of sewage treatment from toxic heavy metals ions. The mentioned above problems are scantily studied both in experimental, and in the theoretical point of view. Expected scientific novelty of the offered project can be made in the following: Technological modes of carrying out of deep clearing processes of real sewage from toxic impurities, in particular from heavy metals ions

  9. Assessment of heavy metal pollution risks and enzyme activity of meadow soils in urban area under tourism load: a case study from Zakopane (Poland).

    Science.gov (United States)

    Ciarkowska, Krystyna

    2018-05-01

    Effect of tourism, especially skiing activities, and urbanization on chemical and biochemical properties of soils in touristy town-Zakopane-was investigated. The concentration of heavy metals, nutrients, soil organic matter (SOM), dehydrogenase (DHA), invertase (IA) and urease (Ure) activities in soils from the town centre and out of the town centre was compared with the respective values of adjacent soils in protected areas (TNP). In order to evaluate a degree of contamination and risks of degradation enrichment factor (EF), ecological risk index (RI), Nemerov Pollution Index (PI Nemerov ) as well as enzyme activity index (EAI) were calculated. Soils in the centre of Zakopane were polluted with Zn, Pb, Cd and Cu in a moderate degree when those of skiing areas were polluted with Pb and Cd in a high degree. Strong positive correlation between these metals and negative correlation between them and a distance from the main roundabout in town indicated their anthropogenic origin. Soils of both locations were also enriched in P, but depleted in SOM when compared to TNP soils. Soils of touristy areas (out of the centre) were additionally enriched in N. Activity of studied enzymes was also lowered in soils of Zakopane when compared to soils of TNP. Pollution indices, RI, PI Nemerov as well as EAI, indicated that soils of Zakopane are at risk of degradation. Soils of touristy areas are under stronger negative impact than soils of the centre because of the cumulative effect of transport of heavy metals from the city centre, pollution by skiing machinery and melting water from the artificial snow.

  10. Estimating risks for water-quality exceedances of total-copper from highway and urban runoff under predevelopment and current conditions with the Stochastic Empirical Loading and Dilution Model (SELDM)

    Science.gov (United States)

    Granato, Gregory E.; Jones, Susan C.; Dunn, Christopher N.; Van Weele, Brian

    2017-01-01

    The stochastic empirical loading and dilution model (SELDM) was used to demonstrate methods for estimating risks for water-quality exceedances of event-mean concentrations (EMCs) of total-copper. Monte Carlo methods were used to simulate stormflow, total-hardness, suspended-sediment, and total-copper EMCs as stochastic variables. These simulations were done for the Charles River Basin upstream of Interstate 495 in Bellingham, Massachusetts. The hydrology and water quality of this site were simulated with SELDM by using data from nearby, hydrologically similar sites. Three simulations were done to assess the potential effects of the highway on receiving-water quality with and without highway-runoff treatment by a structural best-management practice (BMP). In the low-development scenario, total copper in the receiving stream was simulated by using a sediment transport curve, sediment chemistry, and sediment-water partition coefficients. In this scenario, neither the highway runoff nor the BMP effluent caused concentration exceedances in the receiving stream that exceed the once in three-year threshold (about 0.54 percent). In the second scenario, without the highway, runoff from the large urban areas in the basin caused exceedances in the receiving stream in 2.24 percent of runoff events. In the third scenario, which included the effects of the urban runoff, neither the highway runoff nor the BMP effluent increased the percentage of exceedances in the receiving stream. Comparison of the simulated geometric mean EMCs with data collected at a downstream monitoring site indicates that these simulated values are within the 95-percent confidence interval of the geometric mean of the measured EMCs.

  11. 26 CFR 1.142(a)(5)-1 - Exempt facility bonds: Sewage facilities.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Exempt facility bonds: Sewage facilities. 1.142... Bonds § 1.142(a)(5)-1 Exempt facility bonds: Sewage facilities. (a) In general. Under section 103(a), a... in section 142(a) is a sewage facility. This section defines the term sewage facility for purposes of...

  12. Applying SWAT to predict ortho-phosphate loads and trophic status in four reservoirs in the upper Olifants catchment, South Africa

    CSIR Research Space (South Africa)

    Dabrowski, James M

    2014-07-01

    Full Text Available Excessive phosphate loading in the upper Olifants River, South Africa has resulted in widespread eutrophication and associated ecosystem health impacts. The majority of sewage treatment works (STWs) are operating poorly and are likely an important...

  13. Radiocarbon measurements of dissolved organic carbon in sewage-treatment-plant effluent and domestic sewage

    International Nuclear Information System (INIS)

    Nara, Fumiko Watanabe; Imai, Akio; Matsushige, Kazuo; Komatsu, Kazuhiro; Kawasaki, Nobuyuki; Shibata, Yasuyuki

    2010-01-01

    In an attempt to better characterize dissolved organic carbon (DOC) in several specific sources to Lake Kasumigaura, such as sewage-treatment-plant effluent (STPE), domestic sewage (DS) and forest stream (FS), we analyzed radiocarbon ( 14 C) and stable carbon isotopic compositions ( 13 C) of the DOCs. The measurements of 14 C for DOC were performed by an accelerator mass spectrometer (AMS) at the National Institute for Environmental Studies (NIES-TERRA) in Japan. The Δ 14 C and δ 13 C values of the DOCs in several sources to Lake Kasumigaura, have low carbon isotopic values, ranging from -470 per mille to -79 per mille and from -27.9 per mille to -24.2 per mille , respectively. These carbon isotopic values are substantially different from those of Lake Kasumigaura. These results imply different origins for the DOC in Lake Kasumigaura. The 14 C and 13 C analyses of DOC led to a useful classification for DOCs in Lake Kasumigaura, Japan.

  14. Hepatitis E Virus Genotype 4 Sequences Detected in Sewage from Treatment Plants of China

    OpenAIRE

    Li, Heng; Li, Wei; She, Ruiping; Yu, Liang; Wu, Qiaoxing; Yang, Jingling; Hu, Fengjiao; Soomro, Majid Hussain; Shi, Ruihan; Hao, Wenzhuo; Zhao, Yue; Mao, Jingjing

    2017-01-01

    The aim of this study was to investigate the occurrence of hepatitis E virus (HEV) in sewage samples in Shen Zhen, China. Sewage samples were collected from 152 sewage plants including livestock sewage, domestic sewage and treated sewage from May to July of 2015. Two of 152 samples were HEV positive (1.32%) from the livestock sewage plants. Partial ORF2 fragments of HEV were sequenced and a phylogenetic tree was constructed using MEGA5.1. Blast and phylogenetic analyses showed that both of th...

  15. Presence of Methicillin Resistant Staphylococcus aureus (MRSA) in sewage treatment plant.

    Science.gov (United States)

    Boopathy, Raj

    2017-09-01

    The presence of antibiotic resistant bacteria and antibiotic resistance genes in rural sewage treatment plants are not well reported in the literature. The aim of the present study was to study the frequency occurrence of Methicillin Resistant Staphylococcus aureus (MRSA) in a rural sewage treatment plant. This study was conducted using raw sewage as well as treated sewage from a small town sewage treatment plant in rural southeast Louisiana of USA. Results showed the presence of MRSA consistently in both raw and treated sewage. The presence of mecA gene responsible for methicillin resistance was confirmed in the raw and treated sewage water samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Pilot-scale anaerobic co-digestion of sewage sludge with agro-industrial by-products for increased biogas production of existing digesters at wastewater treatment plants.

    Science.gov (United States)

    Maragkaki, A E; Fountoulakis, M; Gypakis, A; Kyriakou, A; Lasaridi, K; Manios, T

    2017-01-01

    Due to low degradability of dry solids, most of the digesters at wastewater treatment plants (WWTP) operate at low loading rates resulting in poor biogas yields. In this study, co-digestion of sewage sludge (SS) with olive mill wastewater (OMW), cheese whey (CW) and crude glycerol (CG) was studied in an attempt to improve biogas production of existing digesters at WWTPs. The effect of agro-industrial by-products in biogas production was investigated using a 220L pilot-scale (180L working volume) digester under mesophilic conditions (35°C) with a total feeding volume of 7.5L daily and a 24-day hydraulic retention time. The initial feed was sewage sludge and the bioreactor was operated using this feed for 40days. Each agro-industrial by-product was then added to the feed so that the reactor was fed continuously with 95% sewage sludge and 5% (v/v) of each examined agro-industrial by-product. The experiments showed that a 5% (v/v) addition of OMW, CG or CW to sewage sludge significantly increased biogas production by nearly 220%, 350% and 86% as values of 34.8±3.2L/d, 185.7±15.3L/d and 45.9±3.6L/d respectively, compared to that with sewage sludge alone (375ml daily, 5% v/v in the feed). The average removal of dissolved chemical oxygen demand (d-COD) ranged between 72 and 99% for organic loading rates between 0.9 and 1.5kgVSm -3 d -1 . Reduction in the volatile solids ranged between 25 and 40%. This work suggests that methane can be produced very efficiently by adding a small concentration (5%) of agro-industrial by-products and especially CG in the inlet of digesters treating sewage sludge. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. INCA Modelling of the Lee System: strategies for the reduction of nitrogen loads

    Science.gov (United States)

    Flynn, N. J.; Paddison, T.; Whitehead, P. G.

    The Integrated Nitrogen Catchment model (INCA) was applied successfully to simulate nitrogen concentrations in the River Lee, a northern tributary of the River Thames for 1995-1999. Leaching from urban and agricultural areas was found to control nitrogen dynamics in reaches unaffected by effluent discharges and abstractions; the occurrence of minimal flows resulted in an upward trend in nitrate concentration. Sewage treatment works (STW) discharging into the River Lee raised nitrate concentrations substantially, a problem which was compounded by abstractions in the Lower Lee. The average concentration of nitrate (NO3) for the simulation period 1995-96 was 7.87 mg N l-1. Ammonium (NH4) concentrations were simulated less successfully. However, concentrations of ammonium rarely rose to levels which would be of environmental concern. Scenarios were run through INCA to assess strategies for the reduction of nitrate concentrations in the catchment. The conversion of arable land to ungrazed vegetation or to woodland would reduce nitrate concentrations substantially, whilst inclusion of riparian buffer strips would be unsuccessful in reducing nitrate loading. A 50% reduction in nitrate loading from Luton STW would result in a fall of up to 5 mg N l-1 in the reach directly affected (concentrations fell from maxima of 13 to 8 mg N l-1 , nearly a 40 % reduction), whilst a 20% reduction in abstractions would reduce maximum peaks in concentration in the lower Lee by up to 4 mg l-1 (from 17 to 13 mg N l-1, nearly a 25 % reduction),.

  18. Pysical Properties of Soil with Addition of Sewage Dried with Heated Edible Oil

    OpenAIRE

    大坪, 政美; 中司, 敬; 中園, 修三; 中園, 英司; 徳留, 斉将

    2000-01-01

    The present study investigates the water holding capacity, density, permeability, and swelling properties of the soil samples mixed with the sewage that was dried with heated edible oil. For comparison similar experiments were conducted for the soil samples mixed with sun-dried sewage and sewage compost. The water holding capacity was higher for the soil samples with oil-dried and sun-dried sewage addition than for those with sewage-compost addition. For statically compacted soil samples, wit...

  19. Radiation Fusion Technology for Sewage Sterilization

    International Nuclear Information System (INIS)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H.

    2011-01-01

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  20. Certification of power generation from sewage gas

    International Nuclear Information System (INIS)

    Ronchetti, C.

    2004-01-01

    This article discusses the certification of power generated from sewage gas in packaged co-generation units in Switzerland. Since 2003, such electricity can be sold as 'green power' to consumers, who pay an additional charge for this ecologically generated power. Since the eco-balance of this electricity generated in wastewater treatment plant is considered as being excellent, the prestigious 'Naturemade Star' label has been awarded to it. This label sets most stringent requirements. The Canius wastewater treatment plant in the 'Lenzerheide' in eastern Switzerland is taken as an example to illustrate the procedure that has to be gone through to receive certification. This certification is carried out by independent auditors and guarantees that the 'green' electricity offered by the utility meets the high ecological criteria set by the label

  1. Radiation hygienization of raw sewage sludge

    International Nuclear Information System (INIS)

    Shah, M.R.; Lavale, D.S.; Rawat, P.; Benny, P.G.; Sharma, A.K.; Dey, G.R.; Bhave, V.

    2001-01-01

    'Radiation treatment of municipal sewage sludge can achieve resource conservation and recovery objectives. The liquid sludge irradiator of Sludge Hygienization Research Irradiator at Baroda (India) was operated for generating data on treatment of raw sludge containing 3-4 % solids. The plant system was modified for irradiating raw sludge without affecting basic irradiator initially designed to treat digested sludge. Hourly samples were analysed for estimation of disinfection dose requirement. Sand separated from the sludge was used as in-situ dosimeter by making use of its thermoluminescence property. Investigations are being carried out for regrowth of Total Coliforms in the sludge samples from this irradiator. Possibility of inadequate treatment due to geometric configuration of irradiator is being checked. (author)

  2. Putative radioresistant bacterial isolate from sewage water

    International Nuclear Information System (INIS)

    Ang, April; Chua, Patricia; Perez, Kristine; Rey, April; Rivor Kristel; San Pablo, Czarina; Santos, Ernestine

    2001-01-01

    Sewage water was collected from a stagnant body of water in Balara, Quezon City. approximately 150 ml was aseptically transferred into eight Erlenmeyer flasks. Seven flasks were then subjected to different doses of radiation at the 60 Co irradiation facility, PNRI (Philippine Nuclear Research Institute) which are as follows: 0.01 kGy, 0.1 kGy, 0.5 kGy, 1 kGy, 5 kGy, 10 kGy, and 15 kGy. The remaining flask was used as the control. After irradiation, all the different treatments were subjected to colony count at the culture collection laboratory, NSRI. Results showed that the colonies from sewage water treatments irradiated at 0.01 kGy (treatment A), 0.10 kGy (treatment B), and 0.50 kGy (treatment C) exhibited a decreasing trend with colony counts 4.60 x 10 3 CFU/ml, and 1.30 x 10 3 CFU/ml, and 26 CFU/ml, respectively. Contrastingly, at 1 kGy (treatment D), high colony count of 2.95 x 10 3 CFU/ml was observed which is even higher compared to the control (1.02 x 10 3 CFU/ml). Treatment E that was irradiated at 5 kGy manifested low survival rate (25 CFU/ml) indicating the presence of few putative intermediate radioresistant bacteria. Radiation dose treatments higher than 5 kGy (i.e., 10 kGy and 15 kGy) exhibited no bacterial survival. (Author)

  3. Putative radioresistant bacterial isolate from sewage water

    Energy Technology Data Exchange (ETDEWEB)

    Ang, April; Chua, Patricia; Perez, Kristine; Rey, April; Kristel, Rivor; San Pablo, Czarina; Santos, Ernestine

    2001-01-29

    Sewage water was collected from a stagnant body of water in Balara, Quezon City. approximately 150 ml was aseptically transferred into eight Erlenmeyer flasks. Seven flasks were then subjected to different doses of radiation at the {sup 60}Co irradiation facility, PNRI (Philippine Nuclear Research Institute) which are as follows: 0.01 kGy, 0.1 kGy, 0.5 kGy, 1 kGy, 5 kGy, 10 kGy, and 15 kGy. The remaining flask was used as the control. After irradiation, all the different treatments were subjected to colony count at the culture collection laboratory, NSRI. Results showed that the colonies from sewage water treatments irradiated at 0.01 kGy (treatment A), 0.10 kGy (treatment B), and 0.50 kGy (treatment C) exhibited a decreasing trend with colony counts 4.60 x 10{sup 3} CFU/ml, and 1.30 x 10{sup 3} CFU/ml, and 26 CFU/ml, respectively. Contrastingly, at 1 kGy (treatment D), high colony count of 2.95 x 10{sup 3} CFU/ml was observed which is even higher compared to the control (1.02 x 10{sup 3} CFU/ml). Treatment E that was irradiated at 5 kGy manifested low survival rate (25 CFU/ml) indicating the presence of few putative intermediate radioresistant bacteria. Radiation dose treatments higher than 5 kGy (i.e., 10 kGy and 15 kGy) exhibited no bacterial survival. (Author)

  4. Raw Sewage Harbors Diverse Viral Populations

    Science.gov (United States)

    Cantalupo, Paul G.; Calgua, Byron; Zhao, Guoyan; Hundesa, Ayalkibet; Wier, Adam D.; Katz, Josh P.; Grabe, Michael; Hendrix, Roger W.; Girones, Rosina; Wang, David; Pipas, James M.

    2011-01-01

    ABSTRACT At this time, about 3,000 different viruses are recognized, but metagenomic studies suggest that these viruses are a small fraction of the viruses that exist in nature. We have explored viral diversity by deep sequencing nucleic acids obtained from virion populations enriched from raw sewage. We identified 234 known viruses, including 17 that infect humans. Plant, insect, and algal viruses as well as bacteriophages were also present. These viruses represented 26 taxonomic families and included viruses with single-stranded DNA (ssDNA), double-stranded DNA (dsDNA), positive-sense ssRNA [ssRNA(+)], and dsRNA genomes. Novel viruses that could be placed in specific taxa represented 51 different families, making untreated wastewater the most diverse viral metagenome (genetic material recovered directly from environmental samples) examined thus far. However, the vast majority of sequence reads bore little or no sequence relation to known viruses and thus could not be placed into specific taxa. These results show that the vast majority of the viruses on Earth have not yet been characterized. Untreated wastewater provides a rich matrix for identifying novel viruses and for studying virus diversity. Importance At this time, virology is focused on the study of a relatively small number of viral species. Specific viruses are studied either because they are easily propagated in the laboratory or because they are associated with disease. The lack of knowledge of the size and characteristics of the viral universe and the diversity of viral genomes is a roadblock to understanding important issues, such as the origin of emerging pathogens and the extent of gene exchange among viruses. Untreated wastewater is an ideal system for assessing viral diversity because virion populations from large numbers of individuals are deposited and because raw sewage itself provides a rich environment for the growth of diverse host species and thus their viruses. These studies suggest that

  5. Addition of biochar to sewage sludge decreases freely dissolved PAHs content and toxicity of sewage sludge-amended soil.

    Science.gov (United States)

    Stefaniuk, Magdalena; Oleszczuk, Patryk

    2016-11-01

    Due to an increased content of polycyclic aromatic hydrocarbons (PAHs) frequently found in sewage sludges, it is necessary to find solutions that will reduce the environmental hazard associated with their presence. The aim of this study was to determine changes of total and freely dissolved concentration of PAHs in sewage sludge-biochar-amended soil. Two different sewage sludges and biochars with varying properties were tested. Biochars (BC) were produced from biogas residues at 400 °C or 600 °C and from willow at 600 °C. The freely dissolved PAH concentration was determined by means of passive sampling using polyoxymethylene (POM). Total and freely dissolved PAH concentration was monitored at the beginning of the experiment and after 90 days of aging of the sewage sludge with the biochar and soil. Apart from chemical evaluation, the effect of biochar addition on the toxicity of the tested materials on bacteria - Vibrio fischeri (Microtox ® ), plants - Lepidium sativum (Phytotestkit F, Phytotoxkit F), and Collembola - Folsomia candida (Collembolan test) was evaluated. The addition of biochar to the sewage sludges decreased the content of C free PAHs. A reduction from 11 to 43% of sewage sludge toxicity or positive effects on plants expressed by root growth stimulation from 6 to 25% to the control was also found. The range of reduction of C free PAHs and toxicity was dependent on the type of biochar. After 90 days of incubation of the biochars with the sewage sludge in the soil, C free PAHs and toxicity were found to further decrease compared to the soil with sewage sludge alone. The obtained results show that the addition of biochar to sewage sludges may significantly reduce the risk associated with their environmental use both in terms of PAH content and toxicity of the materials tested. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Field-scale electrolysis/ceramic membrane system for the treatment of sewage from decentralized small communities.

    Science.gov (United States)

    Son, Dong-Jin; Kim, Woo-Yeol; Yun, Chan-Young; Kim, Dae-Gun; Chang, Duk; Sunwoo, Young; Hong, Ki-Ho

    2017-07-05

    The electrolysis process adopting copper electrodes and ceramic membrane with pore sizes of 0.1-0.2 μm were consisted to a system for the treatment of sewage from decentralized small communities. The system was operated under an HRT of 0.1 hour, voltage of 24 V, and TMP of 0.05 MPa. The system showed average removals of organics, nitrogen, phosphorus, and solids of up to 80%, 52%, 92%, and 100%, respectively. Removal of organics and nitrogen dramatically increased in proportion to increment of influent loading. Phosphorus and solids were remarkably eliminated by both electro-coagulation and membrane filtration. The residual particulate constituents could also be removed successfully through membrane process. A system composed of electrolysis process with ceramic membrane would be a compact, reliable, and flexible option for the treatment of sewage from decentralized small communities.

  7. 2013 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2012, through October 31, 2013. The report contains, as applicable, the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2013 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. However, soil samples were collected in October from soil monitoring unit SU-014101.

  8. Chemical characterisation and source apportionment of PM1 during massive loading at an urban location in Indo-Gangetic Plain: impact of local sources and long-range transport

    Directory of Open Access Journals (Sweden)

    Prashant Rajput

    2016-07-01

    Full Text Available This study assesses temporal variability and source contributions of PM1 (particles with aerodynamic diameter ≤ 1.0 µm samples (n=51; November 2009–February 2010 from an urban location at Kanpur (26.30°N; 80.13°E; 142 m above mean sea-level in the Indo-Gangetic Plain (IGP. A study period from November to February is preferred owing to massive loading of particulate matter in entire IGP. PM1 varies from 18 to 348 (Avg±SD: 113±72 µg m−3 in this study. A total of 11 trace metals, five major elements and four water-soluble inorganic species (WSIS have been measured. Mass fraction of total metals (∑metals=trace+major centres at 18±14 %, of which nearly 15 % is contributed by major elements. Furthermore, ∑WSIS contributes about 26 % to PM1 mass concentration. Abundance pattern among assessed WSIS in this study follows the order: ≈> > Cl−. The K-to-PM1 mass fraction (Avg: 2 % in conjunction with air-mass back trajectories (AMBT indicates that the prevailing north-westerly winds transport biomass burning derived pollutants from upwind IGP. A recent version of positive matrix factorisation (PMF 5.0 has been utilised to quantify the contribution of fine-mode aerosols from various sources. The contribution from each source is highly variable and shows a strong dependence on AMBT. Events with predominant contribution from biomass burning emission (>70 % indicate origin of air-masses from source region upwind in IGP. One of the most interesting features of our study relates to the observation that secondary aerosols (contributing as high as ~60 % to PM1 loading are predominantly derived from stationary combustion sources (/ ratio: 0.30±0.23. Thus, our study highlights a high concentration of PM1 loading and atmospheric fog prevalent during wintertime can have a severe impact on atmospheric chemistry in the air-shed of IGP.

  9. Aspects of land application of sewage solids and gamma-irradiated dried sewage solids on calcareous soils

    International Nuclear Information System (INIS)

    McCaslin, B.D.; O'Connor, G.A.; Sivinski, J.S.

    1980-01-01

    One of the cheapest and generally most convenient methods of disposing of sewage sludge is by land application. The greatest risks of land application are potential contamination of the environment by heavy metals, other toxicants, and pathogens. Irradiation of sewage sludge has been shown to have little or no effect on sludge elements available to plants, and can remove the potential pathogen problem. Work at New Mexico State University has shown that, with little risk, gamma-irradiated sewage sludge can be used to great advantage for crop production, especially on highly calcareous soils low in heavy metals essential for plant growth

  10. ANALYSIS OF HYDRAULIC LOAD OF SELECTED WASTEWATER TREATMENT PLANT IN JASŁO COUNTY

    Directory of Open Access Journals (Sweden)

    Dariusz Piotr Młyński

    2016-12-01

    Full Text Available The paper presents an analysis of hydraulic load in selected a wastewater treatment plant (WTP in Jasło County: in Przysieki, Kołaczyce and Szebnie. The study was based on the records of daily sewage volume entering the treatment plants within a multi-year period of 2011-2014. The analysis took into account the average daily amount of incoming sewage, the maximum daily peaking factor for the incoming sewage, changes in the sewage volume depending on specific month and the intervals with the greatest frequency of occurrence were designated. The analysis revealed that investigated wastewater treatment plants were hydraulically underloaded. Moreover it was conclude a significant variables of inflowing sewage amount. The sewage admission was the largest in spring and summer periods. Sewage volume interval most often occurring at the WTP in Przysieki was the one between 320 and 480 m3•d-1, for Kołaczyce between 290 and 320 m3•d-1 and Szebnie between 120 and 240 m3•d-1.

  11. Use of sewage sludge for agriculture in Japan

    International Nuclear Information System (INIS)

    Kumazawa, K.

    1997-01-01

    In Japan, the use of sewage sludge and composted sewage sludge is gradually increasing. They are applied not only to agricultural land, but also to golf courses, parks, etc. The presence of heavy metals and pathogens poses a major problem for such utilization of sludge. Composting is a traditional method of sewage treatment. Laws have been introduced and guidelines prepared for proper and safe use of these materials by farmers. Public acceptance plays a crucial role. At a time when environmental preservation is a major issue in almost every aspect of life, greater emphasis will have to be placed on making sludge and compost hygienically acceptable with minimum contamination from pathogenic organisms and heavy metals. The advantages of using sludges as fertilizer for improving and sustaining soil fertility and crop production are many. This paper reviews studies conducted on the use of sewage sludge in agriculture in japan. (author)

  12. Fermentation of sewage sludge using the MixAlco process

    African Journals Online (AJOL)

    Nafiisah

    Sewage sludge consists mainly of the excess biomass produced during biological treatment ... The traditional method of converting biomass to alcohol is by simultaneous saccharification .... Lime pretreatment and enzymatic hydrolysis of corn ...

  13. modeling of evaporation modeling of evaporation losses in sewage

    African Journals Online (AJOL)

    eobe

    ffective treatment of wastes derived from households' septic systems. Data generated ... incineration and co-incineration of sludge, facilitate handling for ... environment [3]. Drying beds ..... management of sewage sludge derived from various.

  14. Sandis irradiator for dried sewage solids. Final safety analysis report

    International Nuclear Information System (INIS)

    Morris, M.

    1980-07-01

    Analyses of the hazards associated with the operation of the Sandia irradiator for dried sewage solids, as well as methods and design considerations to minimize these hazards, are presented in accordance with DOE directives

  15. TRIMETHOPRIM-SULFAMETHOXAZOLE RESISTANCE IN SEWAGE ISOLATES OF ESCHERICHIA COLI

    Science.gov (United States)

    Sewage samples from seven locations in the United States were analyzed for Escherichia coli isolates which were resistant to trimethoprim-sulfamethoxazole (SXT). The prevalence rate of SXT resistant organisms varied between the different geographical locales. The majority of th...

  16. Dried, irradiated sewage solids as supplemental feed for cattle

    International Nuclear Information System (INIS)

    Smith, G.S.; Kiesling, H.E.; Ray, E.E.; Orcasberro, R.; Trujillo, P.; Herbel, C.H.; Sivinski, J.S.

    1980-01-01

    Sewage solids were collected as 'primary settled solids' and then dried and gamma-irradiated (using 60 Co or 177 Cs) to absorbed dosage of about one magarad to minimize viable parasites and pathogenic organisms. Nutrient composition and bioassays suggested prospective usage as supplemental feed for ruminants. In a large-scale experiment, beef cows grazing poor-quality rangeland forage during late gestation-early lactation were given either no supplemental feed or cottonseed meal or experimental supplement comprised of 62% sewage solids. Supplements were provided for 13 weeks until rangeland forage quality improved seasonably. Supplemental cottenseed meal for cows improved weaning weights of calves by about 11% over unsupplemented controls; whereas, supplement with 62% sewage solids improved calf weaning weights by about 7%. Hazards or risks to animals or to human health appear to be slight when sewage solids of this type are fed as supplemental feeds to cattle in production programs of this type. (Auth.)

  17. assessment of fecal bacteria contamination in sewage and non

    African Journals Online (AJOL)

    Mgina

    ABSTRACT. Microbiological quality of the intertidal pool water was evaluated in sewage impacted (Mtoni ... forest's act as filtering systems by trapping ... mangrove filtration will be useful in ..... enough to make decisions such as closure of.

  18. Vessel Sewage Discharges: No-Discharge Zones (NDZs)

    Science.gov (United States)

    States may petition the EPA to establish areas, called no discharge zones (NDZs), where vessel sewage discharges are prohibited. This page describes how NDZs are designated, the types of designations, who enforces them, and how to comply.

  19. Effect of treated sewage on growth of marine algae

    Digital Repository Service at National Institute of Oceanography (India)

    Dhargalkar, V.K.

    Eight algal species belonging to Chlorophyta, Rhodophyta and Phaeophyta were used to assess the effect of different concentrations of secondary treated sewage on their growth. Chlorophyta and Rhodophyta members. Ulva fasciata and Gracilaria...

  20. Vitrification as an alternative to landfilling of tannery sewage sludge

    International Nuclear Information System (INIS)

    Celary, Piotr; Sobik-Szołtysek, Jolanta

    2014-01-01

    Highlights: • The possibility of vitrification of tannery sewage sludge was investigated. • Glass cullet was substituted with different wastes of mineral character. • Component ratio in the processed mixtures was optimized. • Environmental safety of the acquired vitrificates was verified. • An alternative management approach of usually landfilled waste was presented. - Abstract: Due to high content of heavy metals such as chromium, tannery sewage sludge is a material which is difficult to be biologically treated as it is in the case of organic waste. Consequently, a common practice in managing tannery sewage sludge is landfilling. This poses a potential threat to both soil and water environments and it additionally generates costs of construction of landfills that meet specific environment protection requirements. Vitrification of this kind of sewage sludge with the addition of mineral wastes can represent an alternative to landfilling. The aim of this study was to investigate the possibility of obtaining an environmentally safe product by means of vitrification of tannery sewage sludge from a flotation wastewater treatment process and chemical precipitation in order to address the upcoming issue of dealing with sewage sludge from the tannery industry which will be prohibited to be landfilled in Poland after 2016. The focus was set on determining mixtures of tannery sewage sludge with additives which would result in the lowest possible heavy metal leaching levels and highest hardness rating of the products obtained from their vitrification. The plasma vitrification process was carried out for mixtures with various amounts of additives depending on the type of sewage sludge used. Only the materials of waste character were used as additives. One finding of the study was an optimum content of mineral additives in vitrified mixture of 30% v/v waste molding sands with 20% v/v carbonate flotation waste from the zinc and lead industry for the formulations with

  1. Vitrification as an alternative to landfilling of tannery sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    Celary, Piotr, E-mail: pcelary@is.pcz.czest.pl; Sobik-Szołtysek, Jolanta, E-mail: jszoltysek@is.pcz.czest.pl

    2014-12-15

    Highlights: • The possibility of vitrification of tannery sewage sludge was investigated. • Glass cullet was substituted with different wastes of mineral character. • Component ratio in the processed mixtures was optimized. • Environmental safety of the acquired vitrificates was verified. • An alternative management approach of usually landfilled waste was presented. - Abstract: Due to high content of heavy metals such as chromium, tannery sewage sludge is a material which is difficult to be biologically treated as it is in the case of organic waste. Consequently, a common practice in managing tannery sewage sludge is landfilling. This poses a potential threat to both soil and water environments and it additionally generates costs of construction of landfills that meet specific environment protection requirements. Vitrification of this kind of sewage sludge with the addition of mineral wastes can represent an alternative to landfilling. The aim of this study was to investigate the possibility of obtaining an environmentally safe product by means of vitrification of tannery sewage sludge from a flotation wastewater treatment process and chemical precipitation in order to address the upcoming issue of dealing with sewage sludge from the tannery industry which will be prohibited to be landfilled in Poland after 2016. The focus was set on determining mixtures of tannery sewage sludge with additives which would result in the lowest possible heavy metal leaching levels and highest hardness rating of the products obtained from their vitrification. The plasma vitrification process was carried out for mixtures with various amounts of additives depending on the type of sewage sludge used. Only the materials of waste character were used as additives. One finding of the study was an optimum content of mineral additives in vitrified mixture of 30% v/v waste molding sands with 20% v/v carbonate flotation waste from the zinc and lead industry for the formulations with

  2. THE IMPACT OF SEWAGE TREATMENT PLANT ON THE AMOUNT OF HEAVY METALS IN WATER OF THE SUPRAŚL RIVER CATCHMENT AREA

    Directory of Open Access Journals (Sweden)

    Mirosław Skorbiłowicz

    2016-01-01

    Full Text Available The main purpose of this study was to evaluate the effect of treated sewage flowing from sewage treatment plants located in the basin of the Supraśl river on the concentration and load of metals in river waters and its main tributaries. Three measuring- control points were chosen, on the river and its tributaries, located near Gródek, Sokółka and Dobrzyniewo. Selected points were located behind the discharge of treated wastewater from sewage treatment plants respectively – Gródek, Sokółka and Bialystok. The samples of treated sewage and water were collected in a period from May to November, once a month in 2014. Each individual sample was examined for the content of dissolved form of the following metals: Pb2+, Cu2+, Cd2+, Ni2+, Zn2+, Fe2+/3+. After taking into account water flow of the Biała, Sokołda and Supraśl in every month, metals loads expressed in mg·h-1, transported by the Supraśl and its tributaries waters were calculated. In the study monthly metals loads discharged into the Biała, Sokołda and Supraśl by sewage treatment plants in Białystok, Sokółka and Gródek were also calculated. The studies have shown the impact of metals load in treated wastewater on metals loads in waters of studied rivers based on the obtained correlation. Most of the searched relations between loafs of Pb2+ – r = 0,88; Cd2+ – r = 0,98; Fe2+/3+ – r = 0,45; Ni2+ – r = 0,55; Zn2+ – r = 0,86 were obtained in case of wastewater treatment plant in Gródek and Supraśl waters. In the study period we observed a diversity in concentration of Cd2+, Fe2+/3+, Ni2+ and Zn2+ in treated sewage and in river waters, which affected loads of this metals.

  3. Using fecal sterols to assess dynamics of sewage input in sediments along a human-impacted river-estuary system in eastern China.

    Science.gov (United States)

    He, Ding; Zhang, Kai; Tang, Jianhui; Cui, Xingqian; Sun, Yongge

    2018-05-01

    Sedimentary fecal sterols and other sterol biomarkers, combined with bulk total organic carbon (TOC) and its stable carbon isotope were applied to characterize the sewage contamination across a ca. 280 km transect from the Xiaoqing River to the Laizhou Bay, a typical river-estuary system subjected to extensive anthropogenic stress due to rapid regional urbanization and industrialization in eastern China. Two sampling events were performed in both spring and summer seasons in the Laizhou Bay adjacent to the Xiaoqing River in order to assess the potential seasonal variation. Fecal sterols such as coprostanol and epicoprostanol, which are typical indicators of anthropogenic sewage input, displayed high concentrations of up to 63.2 μg g -1 dry weight (dw) and 13.1 μg g -1 dw, respectively. Results suggested that most of the stations along the Xiaoqing River were severely contaminated by fecal inputs with a decreasing trend from the river to the estuary that was mainly explained by the increasing distance from the diffuse sewage sources and the gradual dilution by sea water. Although there was no significant difference in fecal sterol concentrations between spring and summer in the Laizhou Bay, suggestive of no significant difference in sewage abundance, significantly higher average epicoprostanol/coprostanol and lower coprostanol/epicoprostanol ratios were observed in spring than summer, indicative of different sewage sources (e.g., human vs. non-human). Seasonal discharge and land-runoff, air temperature related to microbial activity differences and different extend of animal manure irrigation during agricultural planting could be additional reasons and need further investigation. Nevertheless, fecal sterol concentrations, distributions and diagnostic ratios should all be taken into consideration to better understand sewage inputs and source dynamics in river-estuary ecosystems. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. The key to sewage sludge disposal. Wohin mit dem Klaerschlamm

    Energy Technology Data Exchange (ETDEWEB)

    Florin, G. (Sulzer-Escher Wyss GmbH, Fliessbett-Technik, Ravensburg (Germany))

    1994-01-01

    At the sewage treatment plant in Dornbirn (Austria), the quality of the treated effluent is so good that trout can be seen swimming in the outfall. Nevertheless, the quantity of removed polluting matter has posed a real problem for the persons responsible. In their efforts to find a means for reducing the volume of sewage sludge, they came across the so-called fluidbed drying process. (orig.)

  5. Odor assessment for sewage sludge samples 300A01002

    International Nuclear Information System (INIS)

    Cash, D.B.; Molton, P.M.

    1976-12-01

    The use of radiation as a means of detoxifying sewage sludge as an alternate to the more conventional biological digestion treatment method was studied. A combination of gamma irradiation and heat (thermoradiation) treatment is being considered. In support of this effort, Battelle's Pacific Northwest Laboratories (PNL) were requested to assess the odor change of the sewage sludge, if any, that occurs with time after the samples were subjected to the treatment conditions. The test methods and results are presented

  6. Dynamics of pollution-indicator and heterotrophic bacteria in sewage treatment lagoons.

    Science.gov (United States)

    Legendre, P; Baleux, B; Troussellier, M

    1984-09-01

    The spatio-temporal dynamics of pollution-indicator bacteria and aerobic heterotrophic bacteria were studied in the sewage treatment lagoons of an urban wastewater center after 26 months of biweekly sampling at eight stations in these lagoons. Robust statistical methods of time-series analysis were used to study successional steps (through chronological clustering) and rhythmic behavior through time (through contingency periodogram). The aerobic heterotrophic bacterial community showed two types of temporal evolution: in the first four stations, it seems mainly controlled by the nutrient support capacity of the sewage input, whereas in the remaining part of the lagoon, it seems likely that the pollution-indicator bacteria are gradually replaced by other bacterial types that are better adapted to this environment. On the other hand, the pollution-indicator bacteria showed an annual cycle which increased in amplitude at distances further from the wastewater source. The main events in this cycle were produced simultaneously at all stations, indicating control of these bacterial populations by climatic factors, which act through physical and chemical factors, and also through other biological components of this ecosystem (phytoplankton and zooplankton). Finally, we use results from this study to suggest a modified design for a future study program.

  7. Removal of emerging contaminants in sewage water subjected to advanced oxidation with ozone.

    Science.gov (United States)

    Ibáñez, M; Gracia-Lor, E; Bijlsma, L; Morales, E; Pastor, L; Hernández, F

    2013-09-15

    Advanced oxidation processes (AOP) based on ozone treatments, assisted by ultrasounds, have been investigated at a pilot-plant scale in order to evaluate the removal of emerging contaminants in sewage water. Around 60 emerging contaminants, mainly pharmaceuticals from different therapeutically classes and drugs of abuse, have been determined in urban wastewater samples (treated and untreated) by LC-MS/MS. In a first step, the removal efficiency of these contaminants in conventional sewage water treatment plants was evaluated. Our results indicate that most of the compounds were totally or partially removed during the treatment process of influent wastewater. Up to 30 contaminants were quantified in the influent and effluent samples analysed, being antibiotics, anti-inflammatories, cholesterol lowering statin drugs and angiotensin II receptor antagonists the most frequently detected. Regarding drugs of abuse, cocaine and its metabolite benzoylecgonine were the most frequent. In a second step, the effectiveness of AOP in the removal of emerging contaminants remaining in the effluent was evaluated. Ozone treatments have been proven to be highly efficient in the removal, notably decreasing the concentrations for most of the emerging contaminants present in the water samples. The use of ultrasounds, alone or assisting ozone treatments, has been shown less effective, being practically unnecessary. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Evaluation of the efficiency of peracetic acid in the disinfection of sewage effluents.

    Science.gov (United States)

    Stampi, S; De Luca, G; Zanetti, F

    2001-11-01

    Evaluation of the efficiency of peracetic acid in the disinfection of wastewater in a large treatment plant. Over a period of 18 months 30 sample collections were made, each consisting of three samples taken from: raw incoming sewage, secondary effluent (after 10-12 h) and secondary effluent disinfected with 1.5-2 mg l(-1) of peracetic acid (contact time: 20 min). Total coliforms and Escherichia coli declined from 10(7) MPN 100 ml(-1) in the raw sewage to 10(2) in the disinfected effluent and the enterococci fell from 10(6) MPN 100 ml(-1) to 702 MPN 100 ml(-1). The reduction of bacteria increased with the rise in temperature and decreased with the rise in BOD5. Disinfection with peracetic acid reduced levels of faecal contamination by 97%, thus attaining the limit recommended by current Italian law (Escherichia coli disinfection with peracetic acid is easier to manage than other more common methods and the tests performed confirm that from the bacteriological point of view good results can be obtained for urban effluents.

  9. Wood ash to treat sewage sludge for agricultural use

    Energy Technology Data Exchange (ETDEWEB)

    White, R.K. [Clemson Univ., SC (United States)

    1993-12-31

    About 90% of the three million tons of wood ash generated in the United States from wood burning facilities is being landfilled. Many landfills are initiated tipping fees and/or restrictions on the disposal of special wastes such as ash. The purpose of this work was to evaluate (1) the feasibility of using wood ash to stabilize sewage sludge and (2) the fertilizer and liming value of the sludge/ash mixture on plant response and soil pH. Research showed that wood ash, when mixed with sludge, will produce a pH above 12.0, which meets US EPA criteria for pathogen reduction for land application on non-direct food chain crops. Different ratios of wood ash to sludge mixtures were tested and the 1:1 ratio (by weight) was found to be optimal. Five replications of wood ash from four sources were tested for moisture content, pH and fertilizer nutrients. The pH of the ash/sludge mixture (1:1) on day one ranged from 12.4 to 13.2. In most cases the pH remained the same over a 21 day test or only dropped 0.1 to 0.3 units. Analyses of the mixtures showed that heavy metal concentrations (As, B, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, S, Se, Zn) were low. The 1:1 ash/sludge mixture had a calcium carbonate equivalency of 17%. Green house pot studies using tall fescue grass were loadings of 300 to 750 pounds per acre of TKN-N than for 500 lb/acre of 10-10-10 commercial fertilizer. Plant tissue analysis showed N, P, K, Ca, and Mg levels to be within the sufficiency range for tall fescue.

  10. The presence of contaminations in sewage sludge - The current situation.

    Science.gov (United States)

    Fijalkowski, Krzysztof; Rorat, Agnieszka; Grobelak, Anna; Kacprzak, Malgorzata J

    2017-12-01

    Sewage sludge/biosolids are by-wastes of municipal and industrial wastewater treatment. As sources of nutrients (C, N, P) they are widely used in intensive farming where large supplementation of organic matter to maintain fertility and enhance crop yields is needed. However, according to the report of European Commission published in 2010, only 39% of produced sewage sludge is recycled into agriculture in the European Union. This situation occurs mainly due to the fact, that the sewage sludge may contain a dangerous volume of different contaminants. For over decades, a great deal of attention has been focused on total concentration of few heavy metals and pathogenic bacteria Salmonella and Escherichia coli. The Sewage Sludge Directive (86/278/EEC) regulates the allowable limits of Zn, Cu, Ni, Pb, Cd, Cr and Hg and pathogens and allows for recovery of sludge on land under defined sanitary and environmentally sound conditions. In this paper, a review on quality of sewage sludge based on the publications after 2010 has been presented. Nowadays there are several papers focusing on new serious threats to human health and ecosystem occurring in sewage sludge - both chemicals (such as toxic trace elements - Se, Ag, Ti; nanoparticles; polyaromatic hydrocarbons; polychlorinated biphenyl; perfluorinated surfactants, polycyclic musks, siloxanes, pesticides, phenols, sweeteners, personal care products, pharmaceuticals, benzotriazoles) and biological traits (Legionella, Yersinia, Escherichia coli O157:H7). Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. High congruence of isotope sewage signals in multiple marine taxa

    International Nuclear Information System (INIS)

    Connolly, Rod M.; Gorman, Daniel; Hindell, Jeremy S.; Kildea, Timothy N.; Schlacher, Thomas A.

    2013-01-01

    Highlights: • Sewage inputs are routinely mapped with stable isotopes ( 15 N) in organisms. • We tested whether choice of species influences spatial 15 N distributions. • Spatial gradients were consistent between algae, seagrasses, crabs, and fish. • A match of sewage-N signals in multiple marine taxa has not been reported before. • Spatially-coupled transfers in the food web produce the congruence of N imprints. -- Abstract: Assessments of sewage pollution routinely employ stable nitrogen isotope analysis (δ 15 N) in biota, but multiple taxa are rarely used. This single species focus leads to underreporting of whether derived spatial N patterns are consistent. Here we test the question of ‘reproducibility’, incorporating ‘taxonomic replication’ in the measurement of δ 15 N gradients in algae, seagrasses, crabs and fish with distance from a sewage outfall on the Adelaide coast (southern Australia). Isotopic sewage signals were equally strong in all taxa and declined at the same rate. This congruence amongst taxa has not been reported previously. It implies that sewage-N propagates to fish via a tight spatial coupling between production and consumption processes, resulting from limited animal movement that closely preserves the spatial pollution imprint. In situations such as this where consumers mirror pollution signals of primary producers, analyses of higher trophic levels will capture a broader ambit of ecological effects

  12. In-situ Fluorometers Reveal High Frequency Dynamics In Dissolved Organic Matter For Urban Rivers

    Science.gov (United States)

    Croghan, D.; Bradley, C.; Khamis, K.; Hannah, D. M.; Sadler, J. P.; Van Loon, A.

    2017-12-01

    To-date Dissolved Organic Matter (DOM) dynamics have been quantified poorly in urban rivers, despite the substantial water quality issues linked to urbanisation. Research has been hindered by the low temporal resolution of observations and over-reliance on manual sampling which often fail to capture precipitation events and diurnal dynamics. High frequency data are essential to estimate more accurately DOM fluxes/loads and to understand DOM furnishing and transport processes. Recent advances in optical sensor technology, including field deployable in-situ fluorometers, are yielding new high resolution DOM information. However, no consensus regarding the monitoring resolution required for urban systems exists, with no studies monitoring at lower temporal resolution monitoring. High temporal variation occurs during storm events in TLF and HLF intensity: TLF intensity is highest during the rising limb of the hydrograph and can rapidly decline thereafter, indicating the importance of fast flow-path and close proximity sources to TLF dynamics. HLF intensity tracks discharge more closely, but can also quickly decline during high flow events due to dilution effects. Furthermore, the ratio of TLF:HLF when derived at high-frequency provides a useful indication of the presence and type of organic effluents in stream, which aids in the identification of Combined Sewage Overflow releases. Our work highlights the need for future studies to utilise shorter temporal scales than previously used to monitor urban DOM dynamics. The application of higher frequency monitoring enables the identification of finer-scale patterns and subsequently aids in deciphering the sources and pathways controlling urban DOM dynamics.

  13. Spatial and Temporal Microbial Patterns in a Tropical Macrotidal Estuary Subject to Urbanization

    Directory of Open Access Journals (Sweden)

    Mirjam Kaestli

    2017-07-01

    Full Text Available Darwin Harbour in northern Australia is an estuary in the wet-dry tropics subject to increasing urbanization with localized water quality degradation due to increased nutrient loads from urban runoff and treated sewage effluent. Tropical estuaries are poorly studied compared to temperate systems and little is known about the microbial community-level response to nutrients. We aimed to examine the spatial and temporal patterns of the bacterial community and its association with abiotic factors. Since Darwin Harbour is macrotidal with strong seasonal patterns and mixing, we sought to determine if a human impact signal was discernible in the microbiota despite the strong hydrodynamic forces. Adopting a single impact–double reference design, we investigated the bacterial community using next-generation sequencing of the 16S rRNA gene from water and sediment from reference creeks and creeks affected by effluent and urban runoff. Samples were collected over two years during neap and spring tides, in the dry and wet seasons. Temporal drivers, namely seasons and tides had the strongest relationship to the water microbiota, reflecting the macrotidal nature of the estuary and its location in the wet-dry tropics. The neap-tide water microbiota provided the clearest spatial resolution while the sediment microbiota reflected current and past water conditions. Differences in patterns of the microbiota between different parts of the harbor reflected the harbor's complex hydrodynamics and bathymetry. Despite these variations, a microbial signature was discernible relating to specific effluent sources and urban runoff, and the composite of nutrient levels accounted for the major part of the explained variation in the microbiota followed by salinity. Our results confirm an overall good water quality but they also reflect the extent of some hypereutrophic areas. Our results show that the microbiota is a sensitive indicator to assess ecosystem health even in this

  14. Load leveling air conditioning technology development by unused energy high-level utilization. Summary of achievements by development themes; Miriyo energy kodo katsuyo fuka heijunka reidanbo gijutsu kaihatsu. Kaihatsu temabetsu seika gaiyo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This paper introduces a number of research and development cases on utilization of unutilized energies. In developing the component technology for a thermal plant utilizing low-temperature unutilized energies, the paper introduces a heat exchanger system to collect heat from sea water, a heat exchanger system to collect heat from waste heated area in subways and urban sewage plants, and a high-density heat transportation system using ice plus water slurry or PCM-C plus water slurry. Furthermore, with regard to the heat pump system using low-temperature unutilized hear sources, development was introduced on a 'heat source load responsive heat pump system', which combines a load variation responsive heat pump utilizing river waters with a latent heat storage system using nighttime electric power serving for electric power load leveling. In developing the component technology for a heat plant utilizing high-temperature unutilized energies, introduction was given on a turbine driven turbo type heat pump system, a high-efficiency absorption type heat pump, a waste heat driven absorption type freezer, and an urban type underground heat storage tank. (NEDO)

  15. Preparing sewage sludge for land application or surface disposal: A guide for preparers of sewage sludge on the monitoring, record keeping, and reporting requirements of the federal standards for the use of disposal of sewage sludge, 40 CFR part 503

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    The document focuses on the monitoring, recordkeeping, and reporting requirements that apply to persons who prepare sewage sludge or a material derived from sewage sludge. It defines persons who prepare sewage sludge and then summarizes their general responsibilities. USEPA promulgated at 40 CFR Part 503 Phase 1 of the risk-based regulations that govern the final use or disposal of sewage sludge. The intent of the Federal program is to ensure that the use or disposal of sewage sludge occurs in a way that protects both human health and the environment. The Part 503 regulation establishes general requirements, pollutant limits, operational standards, and management practices, as well as monitoring, recordkeeping, and reporting requirements. These requirements apply to sewage sludge that is land applied, placed on a surface disposal site, or incinerated in a sewage sludge-only incinerator.

  16. River catchment responses to anthropogenic acidification in relationship with sewage effluent: An ecotoxicology screening application.

    Science.gov (United States)

    Oberholster, P J; Botha, A-M; Hill, L; Strydom, W F

    2017-12-01

    Rising environmental pressures on water resources and resource quality associated with urbanisation, industrialisation, mining and agriculture are a global concern. In the current study the upper Olifants River catchment as case study was used, to show that acid mine drainage (AMD) and acid precipitation were the two most important drivers of possible acidification during a four-year study period. Over the study period 59% of the precipitation sampled was classified as acidic with a pH value below 5.6. Traces of acidification in the river system using aquatic organisms at different trophic levels were only evident in areas of AMD point sources. Data gathered from the ecotoxicology screening tools, revealed that discharge of untreated and partially treated domestic sewage from municipal sewage treatment works and informal housing partially mitigate any traces of acidification by AMD and acid precipitation in the main stem of the upper Olifants River. The outcome of the study using phytoplankton and macroinvertebrates as indicator organisms revealed that the high loads of sewage effluent might have played a major role in the neutralization of acidic surface water conditions caused by AMD and acid precipitation. Although previous multi-stage and microcosm studies confirmed the decrease in acidity and metals concentrations by municipal wastewater, the current study is the first to provide supportive evidence of this co-attenuation on catchment scale. These findings are important for integrated water resource management on catchment level, especially in river systems with a complex mixture of pollutants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Enhanced composting of radiation disinfected sewage sludge

    International Nuclear Information System (INIS)

    Kawakami, W.; Hashimoto, S.

    1984-01-01

    Studies on isothermal composting of radiation disinfected sewage sludge and liquid chromatography of water extracts of the products were carried out. The optimum temperature and pH were around 50 deg C and 7 to 8, respectively. The repeated use of products as seeds increased the rate of CO 2 evolution. The rate reached a maximum within 10 hours and decreased rapidly, and the CO 2 evolution ceased after about 3 days. The conversion of organic carbon to carbon dioxide attained to about 40% for the repeated use of products as seeds at the optimum conditions. As long as seeds as available were used, no remarkable difference was found in the composting of unirradiated and irradiated sludges. The composting process using radiation, however, can be carried out at the optimum conditions and is expected to shorten the composting period, because it is not necessary to keep fermentation temperature higher to reduce pathogen in sludge. Liquid chromatographic studies of the products showed that low molecular components decreased and higher molecular ones increased with fermentation. An index expressing the degree of reduction of easily decomposable organics was presented. The index also showed that the optimum temperature for fermentation was 50 deg C. (author)

  18. Rheological properties of disintegrated sewage sludge

    Science.gov (United States)

    Wolski, Paweł

    2017-11-01

    The rheology of the sludge provides information about the capacity and the flow, which in the case of project tasks for the hydraulic conveying installation is an important control parameter. Accurate knowledge of the rheological properties of sludge requires the designation of rheological models. Models single and multiparameter (Ostwald, Bingham, Herschel-Bulkley'a, and others) allow an approximation of flow curves, and the determination of the boundaries of the flow of modified sludge allows you to control the process compaction or are dewatered sludge undergoing flow. The aim of the study was to determine the rheological parameters and rheological models of sludge conditioned by physical methods before and after the process of anaerobic digestion. So far, studies have shown that the application of conditioning in the preparation of sewage sludge increases shear stress, viscosity as well as the limits of flow in relation to the untreated sludge. Offset yield point by the application of a conditioning agent is associated with decreased flowability tested sludge, which has also been observed by analyzing the structure of the prepared samples. Lowering the yield point, and thus the shear stress was recorded as a result of the fermentation test of disintegrated sludge.

  19. A microbiological study on sewage sludge treatment

    International Nuclear Information System (INIS)

    Sermkiattipong, Ngamnit; Ito, Hitoshi; Hashimoto, Shoji.

    1990-09-01

    Isolation and identification of salmonellae in sewage sludge cake and radiation sensitivities of the isolated strains were studied. Disinfection of the sludge by heat or radiation and effect of such treatment on composting were also carried out. Five groups of O-antigen and seven serotypes of salmonellae were identified from the sludge cakes. D 10 values of the salmonellae in phosphate buffer were ranged from 0.16 to 0.22 kGy and those in sludge were about three times larger. Total bacterial counts and coliforms in the sludges were determined to be 4.6 x 10 7 - 5.1 x 10 9 and 1.3 x 10 5 - 1.1 x 10 9 colony forming unit (cfu/g). After irradiation at 20 kGy by gamma ray or electron beam, decrease of total bacterial count was 5 - 7 log cycles and a dose of 5 kGy was enough to eliminate all of the coliforms. Coliforms decreased rapidly by heating at 65degC, but only one log cycle decrease was observed in total bacterial count. By heating at 100degC, total bacterial count decreased rapidly. Two peaks were observed in CO 2 evolution curves of radiation disinfected sludge composting, but only one peak in heat disinfected sludge composting. (author)

  20. On the rheological characteristics of sewage sludge

    Directory of Open Access Journals (Sweden)

    Tomáš Vítěz

    2010-01-01

    Full Text Available The work is focused on characterization of rheological behavior of sewage sludges sampled at different stages of waste water treatment. The main attention was focused on dynamic viscosity dependence on temperature, and shear rate. The sludge samples were examined under temperature ranging from 1 °C to 25 °C and under shear rate ranging from 0.34 s−1 to 68 s−1. Rotary digital viscometer (concentric cylinders geometry was used to perform the reological measurements. The solids content of the sludge samples ranged from 0.43 % to 21.45 % (A and C samples, respectively and ash free dry mass from 56.21 % to 67.80 % (A and B samples, respectively. The tested materials were found to be of non–Newtoninan nature and temperature dependent. Measured data were successfully cha­ra­cte­ri­zed by several mathematical models (Arrhenius, Bingham Plastic, Casson Law, Exponential, Gaussian, and IPC Paste in MATLAB® software with satisfying correlations between experimental and computed results. The best match (R2 = 0.999 was received with use of Gaussian model, in both cases, shear rate and temperature dependence. The results are quite useful e.g. for the purpose of technological equipment design.

  1. Recycling of Treated Sewage Sludge in Sustainable Agriculture

    International Nuclear Information System (INIS)

    Galal, Y.G.M.

    2012-01-01

    Agricultural utilization of organic wastes amendments has been shown to be a sound alternative for both waste recycling and soil fertility improvement. Also, attention had been paid to use the biological agents that most cheap and safe for agricultural application in poor sandy soils. In this respect, irradiated sewage sludge and individual and dual inoculants of Azospirillum, Rhizobium and Arbuscular mycorrhizae fungi were applied for reclamation and development of low fertile sandy soil. The fertilizer value of sewage sludge has been known for a long time, but the concomitant problems of heavy metals in soil, as a result of its continuous applications, have only been recognized recently. Most of the studies were devoted to follow up the effect of high concentrations of metals when sewage sludge was applied, but no attention has been accelerated about its effect on soil microorganisms. Adverse effects of sewage sludge on microbial activity and populations of cyanobacteria, Rhizobium, Mycorrhizae and total microbial biomass have been detected in some cases of Europe. For example, N 2 fixation by free-living heterotrophic bacteria was found to be inhibited at concentrations (mg kg -1 ) of 127 Zn, 37 Cu, 21 Ni, 3.4 Cd, 52 Cr, and 71 Pb. Impact of bio fertilizers combined with irradiated sewage sludge on micro nutrients, e.g. Fe, Zn, Mn, Pb availability to clover and wheat plants, and productivity of both crops was the main objective of this study. In this connection, nuclear technology may offer a safety method against pathogenic effects of sewage sludge applied into agricultural ecosystems. Therefore, irradiated sludge is considered as safely source of organic wastes as well as the benefits on enrichment the low fertile soil with available nutrients, which act as a limiting factor for crop production. The N, P and K nutrients uptake by either shoots or grains of tested crops were positively and significantly affected by application of sewage sludge as well as bio

  2. Sewage treatment in integrated system of UASB reactor and duckweed pond and reuse for aquaculture.

    Science.gov (United States)

    Mohapatra, D P; Ghangrekar, M M; Mitra, A; Brar, S K

    2012-06-01

    The performance of a laboratory-scale upflow anaerobic sludge blanket (UASB) reactor and a duckweed pond containing Lemna gibba was investigated for suitability for treating effluent for use in aquaculture. While treating low-strength sewage having a chemical oxygen demand (COD) of typically less than 200 mg/L, with an increase in hydraulic retention time (HRT) from 10.04 to 33.49 h, COD removal efficiency of the UASB reactor decreased owing to a decrease in organic loading rate (OLR) causing poor mixing in the reactor. However, even at the lower OLR (0.475 kg COD/(m3 x d)), the UASB reactor gave a removal efficiency of 68% for COD and 74% for biochemical oxygen demand (BOD). The maximum COD, BOD, ammonia-nitrogen and phosphate removal efficiencies of the duckweed pond were 40.77%, 38.01%, 61.87% and 88.57%, respectively. Decreasing the OLR by increasing the HRT resulted in an increase in efficiency of the duckweed pond for removal of ammonia-nitrogen and phosphate. The OLR of 0.005 kg COD/(m2 x d) and HRT of 108 h in the duckweed pond satisfied aquaculture quality requirements. A specific growth rate of 0.23% was observed for tilapia fish fed with duckweed harvested from the duckweed pond. The economic analysis proved that it was beneficial to use the integrated system of a UASB reactor and a duckweed pond for treatment of sewage.

  3. A REVIEW ON SEWAGE TREATMENT AND POLISHING USING MOVING BED BIOREACTOR (MBBR

    Directory of Open Access Journals (Sweden)

    JAMAL ALI KAWAN

    2016-08-01

    Full Text Available Effluent treatment and polishing using moving bed bioreactors (MBBRs are advanced technique in biological treatment operations become increasing widely and popular use all over the world to treat various types of effluents with very different operating status. It is a combination of two separate processes suspended and attached growth systems for the treatment in order to minimize the concentrations of the contaminated parameters at the required level for reuse or final destination. The MBBR has been proved to be effective in great removing biochemical oxygen demand (BOD and chemical oxygen demand (COD with nutrients (N and P from the effluent stream simultaneously. It provides additional capacity of wastewater treatment technology with high treatment efficiency; low capital, operational, maintenance and replacement cost; single reliable and robust operation procedure. This process can be used for new sewage treatment works or for modifying (upgrading existing wastewater treatment plants as it is efficient, compact and easy to operate. The efficiency of MBBR depends on the filling percent of biofilm carriers to be provided inside the tank, surface area of the biocarrier, diffused aeration supply and the organic loading. The aim of this paper is reviewing the sewage treatment and polishing using moving bed bioreactor MBB technology as an alternative and successful method. It presents the advantages of the MBBR compared to conventional waste water treatment. The review also includes many relevant researches carried out at the laboratory andpilot scales plants that could improve these systems by enhancing performance and reducing costs.

  4. Pilot plant experience on anaerobic codigestion of source selected OFMSW and sewage sludge.

    Science.gov (United States)

    Cabbai, Valentina; De Bortoli, Nicola; Goi, Daniele

    2016-03-01

    Anaerobic codigestion of source selected organic fraction of municipal solid waste (SS-OFMSW) and sewage sludge may be one of the most viable solutions to optimize oversized digesters efficiency in wastewater treatment plants. Based on results of BMP tests obtained for sewage sludge and SS-OFMSW, pilot plant tests were carried out by 3.4 m(3) CSTR reactor at mesophilic temperature. A mix of fruit and vegetable waste from wholesale market and canteen waste was used as SS-OFMSW substrate. Tests were conducted applying an OLR (organic loading rate) ramp with 6 different phases until a value of 3.2 kgVS/m(3) d. Feedstock and digestate characteristics, efficiency and process parameters were monitored. The anaerobic codigestion development was stable in each phase: early indicators like VFA (volatile fatty acids) and FOS/TAC ratio were always below instability threshold values. The maximum OLR tested determined a GPR (gas production rate) of 0.95 N m(3)/m(3) d and SGP (specific gas production) of 0.49 N m(3)/kgVS with a VS abatement of 67.3%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Effect of biodegradation on the consolidation properties of a dewatered municipal sewage sludge.

    Science.gov (United States)

    O'Kelly, Brendan C

    2008-01-01

    The effect of biodegradation on the consolidation characteristics of an anaerobically digested, dewatered municipal sewage sludge was studied. Maintained-load oedometer consolidation tests that included measurement of the pore fluid pressure response were conducted on moderately degraded sludge material and saturated bulk samples that had been stored under static conditions and allowed to anaerobically biodegrade further (simulating what would happen in an actual sewage sludge monofill or lagoon condition). Strongly degraded sludge material was produced after a storage period of 13 years at ambient temperatures of 5-15 degrees C, with the total volatile solids reducing from initially 70% to 55%. The sludge materials were highly compressible, although impermeable for practical purposes. Primary consolidation generally occurred very slowly, which was attributed to the microstructure of the solid phase, the composition and viscosity of the pore fluid, ongoing biodegradation and the high organic contents. The coefficient of primary consolidation values decreased from initially about 0.35m2/yr to 0.003-0.03m2/yr with increasing effective stress (sigmav'=3-100kPa). Initially, the strongly degraded sludge material was slightly more permeable, although both the moderately and strongly degraded materials became impermeable for practical purposes (k=10(-9)-10(-12)m/s) below about 650% and 450% water contents, respectively. Secondary compression became more dominant with increasing effective stress with a mean secondary compression index (Calphae) value of 0.9 measured for both the moderately and strongly degraded materials.

  6. Chemical state of mercury and selenium in sewage sludge ash based P-fertilizers

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, Christian, E-mail: cv.vogel@yahoo.de [Division 4.4 Thermochemical Residues Treatment and Resource Recovery, Bundesanstalt für Materialforschung und −prüfung (BAM), Unter den Eichen 87, 12205 Berlin (Germany); Krüger, Oliver; Herzel, Hannes [Division 4.4 Thermochemical Residues Treatment and Resource Recovery, Bundesanstalt für Materialforschung und −prüfung (BAM), Unter den Eichen 87, 12205 Berlin (Germany); Amidani, Lucia [ESRF—The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble (France); Adam, Christian [Division 4.4 Thermochemical Residues Treatment and Resource Recovery, Bundesanstalt für Materialforschung und −prüfung (BAM), Unter den Eichen 87, 12205 Berlin (Germany)

    2016-08-05

    Highlights: • Mercury bonded to carbon/organic material was detected in some sewage sludge ashes. • After thermochemcial treatment some mercury remains stabilized in the SSA matrix. • Analysis of the chemical state of mercury and selenium in highly diluted samples. - Abstract: Phosphorus-fertilizers from secondary resources such as sewage sludge ash (SSA) will become more important in the future as they could substitute conventional fertilizers based on the nonrenewable resource phosphate rock. Thermochemical approaches were developed which remove heavy metals from SSA prior to its fertilizer application on farmlands. We analyzed the chemical state of mercury and selenium in SSA before and after thermochemical treatment under different conditions for P-fertilizer production by X-ray absorption near edge structure (XANES) spectroscopy. In some incineration plants the mercury loaded carbon adsorber from off-gas cleaning was collected together with the SSA for waste disposal. SSAs from those plants contained mercury mainly bound to carbon/organic material. The other SSAs contained inorganic mercury compounds which are most probably stabilized in the SSA matrix and were thus not evaporated during incineration. During thermochemical treatment, carbon-bound mercury was removed quantitatively. In contrast, a certain immobile fraction of inorganic mercury compounds remained in thermochemically treated SSA, which were not clearly identified. HgSe might be one of the inorganic compounds, which is supported by results of Se K-edge XANES spectroscopy. Furthermore, the chemical state of selenium in the SSAs was very sensitive to the conditions of the thermochemical treatment.

  7. Adsorption of organic stormwater pollutants onto activated carbon from sewage sludge.

    Science.gov (United States)

    Björklund, Karin; Li, Loretta Y

    2017-07-15

    Adsorption filters have the potential to retain suspended pollutants physically, as well as attracting and chemically attaching dissolved compounds onto the adsorbent. This study investigated the adsorption of eight hydrophobic organic compounds (HOCs) frequently detected in stormwater - including four polycyclic aromatic hydrocarbons (PAHs), two phthalates and two alkylphenols - onto activated carbon produced from domestic sewage sludge. Adsorption was studied using batch tests. Kinetic studies indicated that bulk adsorption of HOCs occurred within 10 min. Sludge-based activated carbon (SBAC) was as efficient as tested commercial carbons for adsorbing HOCs; adsorption capacities ranged from 70 to 2800 μg/g (C initial  = 10-300 μg/L; 15 mg SBAC in 150 mL solution; 24 h contact time) for each HOC. In the batch tests, the adsorption capacity was generally negatively correlated to the compounds' hydrophobicity (log K ow ) and positively associated with decreasing molecule size, suggesting that molecular sieving limited adsorption. However, in repeated adsorption tests, where competition between HOCs was more likely to occur, adsorbed pollutant loads exhibited strong positive correlation with log K ow . Sewage sludge as a carbon source for activated carbon has great potential as a sustainable alternative for sludge waste management practices and production of a high-capacity adsorption material. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Compiled data on the vascular aquatic plant program, 1975 - 1977. [for sewage lagoon

    Science.gov (United States)

    Wolverton, B. C.; Mcdonald, R.

    1977-01-01

    The performance of a single cell, facultative sewage lagoon was significantly improved with the introduction of vascular aquatic plants. Water hyacinth (Eichhornia crassipes) was the dominant plant from April to November; duckweed (Lemna spp.) and (Spirodela spp.) flourished from December to March. This 2 ha lagoon received approximately 475 cu m/day of untreated sewage and has a variable COD sub 5 loading rate of 22-30 kg/ha/day. During the first 14 months of operation with aquatic plants, the average influent BOD sub 5 was reduced by 95% from 110 mg/l to an average of 5 mg/l in the effluent. The average influent suspended solids were reduced by 90% from 97 mg/l to 10 mg/l in the effluent. Significant reductions in nitrogen and phosphorus were effected. The monthly kjeldahl nitrogen for influent and effluent averaged 12.0 and 3.4 mg/l, respectively, a reduction of 72%. The total phosphorus was reduced on an average of 56% from 3.7 mg/l influent to 1.6 mg/l effluent.

  9. Environmental and economic life cycle assessment for sewage sludge treatment processes in Japan.

    Science.gov (United States)

    Hong, Jinglan; Hong, Jingmin; Otaki, Masahiro; Jolliet, Olivier

    2009-02-01

    Life cycle assessment for sewage sludge treatment was carried out by estimating the environmental and economic impacts of the six alternative scenarios most often used in Japan: dewatering, composting, drying, incineration, incinerated ash melting and dewatered sludge melting, each with or without digestion. Three end-of-life treatments were also studied: landfilling, agricultural application and building material application. The results demonstrate that sewage sludge digestion can reduce the environmental load and cost through reduced dry matter volume. The global warming potential (GWP) generated from incineration and melting processes can be significantly reduced through the reuse of waste heat for electricity and/or heat generation. Equipment production in scenarios except dewatering has an important effect on GWP, whereas the contribution of construction is negligible. In addition, the results show that the dewatering scenario has the highest impact on land use and cost, the drying scenario has the highest impact on GWP and acidification, and the incinerated ash melting scenario has the highest impact on human toxicity due to re-emissions of heavy metals from incinerated ash in the melting unit process. On the contrary, the dewatering, composting and incineration scenarios generate the lowest impact on human toxicity, land use and acidification, respectively, and the incinerated ash melting scenario has the lowest impact on GWP and cost. Heavy metals released from atmospheric effluents generated the highest human toxicity impact, with the effect of dioxin emissions being significantly lower. This study proved that the dewatered sludge melting scenario is an environmentally optimal and economically affordable method.

  10. Load forecasting

    International Nuclear Information System (INIS)

    Mak, H.

    1995-01-01

    Slides used in a presentation at The Power of Change Conference in Vancouver, BC in April 1995 about the changing needs for load forecasting were presented. Technological innovations and population increase were said to be the prime driving forces behind the changing needs in load forecasting. Structural changes, market place changes, electricity supply planning changes, and changes in planning objectives were other factors discussed. It was concluded that load forecasting was a form of information gathering, that provided important market intelligence

  11. Real-time estimation of small-area populations with human biomarkers in sewage

    Energy Technology Data Exchange (ETDEWEB)

    Daughton, Christian G., E-mail: daughton.christian@epa.gov

    2012-01-01

    A new approach is conceptualized for measuring small-area human populations by using biomarkers in sewage. The basis for the concept (SCIM: Sewage Chemical-Information Mining) is supported by a comprehensive examination and synthesis of data published across several disciplines, including medicine, microbiology, clinical chemistry, and environmental science. Accurate measures of human populations are fundamental to numerous disciplines, including economics, marketing, politics, sociology, public health and safety (e.g., disease management; assessment of natural hazards; disaster prevention and response), quality of life, and the environment. Knowing the size, distribution, and flow of a small-area (local) population facilitates understanding the numerous and complex linkages and interactions between humans and the environment. Examples include material-flow (substance-flow) analysis, determining the magnitude of per capita contribution of pollutant loadings to watersheds, or forecasting future impacts of local populations on the environment or a population's demands on resources. While no definitive approach exists for measuring small-area populations, census-taking is a long-established convention. No approach exists, however, for gauging small-area populations in real-time, as none is able to capture population dynamics, which involve transient changes (e.g., daily influx and efflux) and lasting changes (e.g., births, deaths, change in residence). Accurate measurement of small-area populations in real time has never been possible but is essential for facilitating the design of more sustainable communities. Real-time measurement would provide communities the capability of testing what-if scenarios in design and policy decisions. After evaluation of a range of biomarkers (including the nitrogenous waste product creatinine, which has been long used in clinical chemistry as a parameter to normalize the concentrations of other urinary excretion products to

  12. Real-time estimation of small-area populations with human biomarkers in sewage

    International Nuclear Information System (INIS)

    Daughton, Christian G.

    2012-01-01

    A new approach is conceptualized for measuring small-area human populations by using biomarkers in sewage. The basis for the concept (SCIM: Sewage Chemical-Information Mining) is supported by a comprehensive examination and synthesis of data published across several disciplines, including medicine, microbiology, clinical chemistry, and environmental science. Accurate measures of human populations are fundamental to numerous disciplines, including economics, marketing, politics, sociology, public health and safety (e.g., disease management; assessment of natural hazards; disaster prevention and response), quality of life, and the environment. Knowing the size, distribution, and flow of a small-area (local) population facilitates understanding the numerous and complex linkages and interactions between humans and the environment. Examples include material-flow (substance-flow) analysis, determining the magnitude of per capita contribution of pollutant loadings to watersheds, or forecasting future impacts of local populations on the environment or a population's demands on resources. While no definitive approach exists for measuring small-area populations, census-taking is a long-established convention. No approach exists, however, for gauging small-area populations in real-time, as none is able to capture population dynamics, which involve transient changes (e.g., daily influx and efflux) and lasting changes (e.g., births, deaths, change in residence). Accurate measurement of small-area populations in real time has never been possible but is essential for facilitating the design of more sustainable communities. Real-time measurement would provide communities the capability of testing what-if scenarios in design and policy decisions. After evaluation of a range of biomarkers (including the nitrogenous waste product creatinine, which has been long used in clinical chemistry as a parameter to normalize the concentrations of other urinary excretion products to account for

  13. Methanogenic degradation of toilet-paper cellulose upon sewage treatment in an anaerobic membrane bioreactor at room temperature.

    Science.gov (United States)

    Chen, Rong; Nie, Yulun; Kato, Hiroyuki; Wu, Jiang; Utashiro, Tetsuya; Lu, Jianbo; Yue, Shangchao; Jiang, Hongyu; Zhang, Lu; Li, Yu-You

    2017-03-01

    Toilet-paper cellulose with rich but refractory carbon sources, are the main insoluble COD fractions in sewage. An anaerobic membrane bioreactor (AnMBR) was configured for sewage treatment at room temperature and its performance on methanogenic degradation of toilet paper was highlighted. The results showed, high organic removal (95%), high methane conversion (90%) and low sludge yield (0.08gVSS/gCOD) were achieved in the AnMBR. Toilet-paper cellulose was fully biodegraded without accumulation in the mixed liquor and membrane cake layer. Bioconversion efficiency of toilet paper approached 100% under a high organic loading rate (OLR) of 2.02gCOD/L/d and it could provide around 26% of total methane generation at most of OLRs. Long sludge retention time and co-digestion of insoluble/soluble COD fractions achieving mutualism of functional microorganisms, contributed to biodegradation of toilet-paper cellulose. Therefore the AnMBR successfully implemented simultaneously methanogenic bioconversion of toilet-paper cellulose and soluble COD in sewage at room temperature. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Zinc Regime in the Sewage Sludge-Soil-Plant System of a City Waste Water Treatment Pond

    Directory of Open Access Journals (Sweden)

    Lacatusu Radu

    2014-10-01

    Full Text Available The sewage sludge from wastewater treatment plant of Iasi, a city with 300,000 inhabitants, for domestic and industrial origin, was stored in a mud pond arranged on an area of 18,920 m2. Chemical analyzes of the sludge showed that, of all the chemical elements determined, only Zn is found at pollutant level (5739 mg∙kg-1, i.e. almost 30 times more than the maximum allowable limit for Zn in soil and 45 times more than the Zn content of the soil on which the mud pond has been set. Over time, the content of Zn in the mud pond, but also from soil to which it has been placed, has become upper the normal content of the surrounding soil up to a depth of 260 cm. On the other hand, the vegetation installed on sewage sludge in the process of mineralization, composed predominantly of Phragmites, Rumex, Chenopodium, and Aster species had accumulated in roots, stems and leaves Zn quantities equivalent to 1463 mg Kg-1, 3988 mg Kg-1, 1463 mg Kg-1, respectively, 1120 mg∙Kg-1. The plants in question represents the natural means of phytoremediation, and sewage sludge as such may constitute a fertilizer material for soils in the area, on which Zn deficiency in maize has been recorded. In addition, the ash resulted from the incineration of plants loaded with zinc may constitute, in its turn, a good material for fertilizing of the soils that are deficient in zinc.

  15. Urban bioclimatology.

    Science.gov (United States)

    Mayer, H

    1993-11-15

    This article deals with the part of urban climatology which is of particular relevance to human beings. Presented first is a summary of all human biometerologically effective complexes, as well as other factors which are relevant to urban planning and which depend on atmospheric conditions in urban structures in a direct or indirect manner. Later, methods for human biometerologically significant assessment of thermal and air pollution components of the urban climate are discussed in detail, because these components can be strongly influenced by urban planning. The application of these methods is illustrated by some results of appropriate investigations in urban areas.

  16. Participatory urbanism

    DEFF Research Database (Denmark)

    Ejsing-Duun, Stine

    2016-01-01

    cannot directly influence their structures, they can influence their contours through such leisure practices. In this chapter focus will be on how citizens’ engagement in locative leisure activities may allow them to co-create urban space. This participatory urbanism is a form of everyday democracy......Urban areas are planned structures that cannot easily be changed. Urban areas do however still afford physical spaces for various types of leisure expression and participation, from street art to parkour and from urban gaming to artistic happenings. Thus, while citizens who inhabit the urban areas...

  17. Streamflow, water quality, and contaminant loads in the lower Charles River Watershed, Massachusetts, 1999-2000

    Science.gov (United States)

    Breault, Robert F.; Sorenson, Jason R.; Weiskel, Peter K.

    2002-01-01

    Streamflow data and dry-weather and stormwater water-quality samples were collected from the main stem of the Charles River upstream of the lower Charles River (or the Basin) and from four partially culverted urban streams that drain tributary subbasins in the lower Charles River Watershed. Samples were collected between June 1999 and September 2000 and analyzed for a number of potential contaminants including nitrate (plus nitrite), ammonia, total Kjeldahl nitrogen, phosphorus, cadmium, chromium, copper, lead, and zinc; and water-quality properties including specific conductance, turbidity, biochemical oxygen demand, fecal coliform bacteria, Entero-coccus bacteria, total dissolved solids, and total suspended sediment. These data were used to identify the major pathways and to determine the magnitudes of contaminants loads that contribute to the poor water quality of the lower Charles River. Water-quality and streamflow data, for one small urban stream and two storm drains that drain subbasins with uniform (greater than 73 percent) land use (including single-family residential, multifamily residential, and commercial), also were collected. These data were used to elucidate relations among streamflow, water quality, and subbasin characteristics. Streamflow in the lower Charles River Watershed can be characterized as being unsettled and flashy. These characteristics result from the impervious character of the land and the complex infrastructure of pipes, pumps, diversionary canals, and detention ponds throughout the watershed. The water quality of the lower Charles River can be considered good?meeting water-quality standards and guidelines?during dry weather. After rainstorms, however, the water quality of the river becomes impaired, as in other urban areas. The poor quality of stormwater and its large quantity, delivered over short periods (hours and days), together with illicit sanitary cross connections, and combined sewer overflows, results in large contaminant

  18. ZEOLITIZATION OF SEWAGE SLUDGE ASH WITH A FUSION METHOD

    Directory of Open Access Journals (Sweden)

    Jolanta Latosińska

    2016-11-01

    Full Text Available The study shows the results of zeolitization of municipal sewage sludge ash with the indirect fusion method followed by a hydrothermal method. The zeolitization of sewage sludge ash was conducted at the melting temperature of 550°C and the melting time of 60 minutes, crystallization temperatures of 60°C and 90°C, crystallization time of 6 hours and the SSA:NaOH ratio of 1:1.8; 1:1.4. The research of modified sewage sludge ashes included the observation of changes of ash particles surface and the identification of crystalized phases. The zeolitization of sewage sludge ash at the ratio of SSA:NaOH 1.0:1.4 did not cause the formation of zeolite phases. On the other hand, the zeolitization at the ratio of SSA:NaOH 1.0:1.8 resulted in the formation of desired zeolite phases such as zeolite Y (faujasite and hydroxysodalite. The presented method of sewage sludge ash zeolitization allows to obtain highly usable material. Synthesized zeolites may be used as adsorbents and ion exchangers. They can be potentially used to remove heavy metals as well as ammonia from water and wastewater.

  19. [Analysis on relationship between regional economic development and sewage disposal].

    Science.gov (United States)

    Wang, La-Chun; Huo, Yu; Zhu, Ji-Ye; Li, Sheng-Feng; Gao, Chao

    2008-03-01

    Based on the relationship between district GDP and sewage disposal, the water environment protection effect in 3 cities, Suzhou, Nanjing and Xuzhou, with different economic development degrees in Jiangsu Province was dynamically analyzed. The economy in Suzhou was well developed, where the foreign capital proportion was in a high level. Its GDP per capita was 53,800 yuan in 2005 and the sewage disposal grew linearly when its GDP increased in the study time period. Nanjing was less developed than Suzhou, and the state-owned enterprises in large and medium sizes were in a high percentage. Its GDP per capita was 37,100 yuan in 2005, while the sewage disposal reduced linearly when its GDP increased in the study time period. The economy in Xuzhou is under-developed, where coal-based heavy industry was the most important one. The GDP per capita in this city was 13,200 yuan in 2005 and the sewage disposal fluctuated when its GDP increased in the study time period. According to the relationship between economic development and sewage disposal in different cities, we suggested that the water environment protection in Suzhou should focus on the control of both water pollutant total emission and emission concentration, the major work in Nanjing should focus on adjusting the industrial structure and meanwhile controlling the total emission of water pollutants, while in Xuzhou the water pollutant emission concentration should be firstly controlled.

  20. Hydrogen and syngas production from sewage sludge via steam gasification

    Energy Technology Data Exchange (ETDEWEB)

    Nipattummakul, Nimit [The Combustion Laboratory, Dept. of Mechanical Engineering, University of Maryland, College Park, MD (United States); The Waste Incineration Research Center, Dept. of Mechanical and Aerospace Engineering, King Mongkut' s University of Technology, North Bangkok (Thailand); Ahmed, Islam I.; Gupta, Ashwani K. [The Combustion Laboratory, Dept. of Mechanical Engineering, University of Maryland, College Park, MD (United States); Kerdsuwan, Somrat [The Waste Incineration Research Center, Dept. of Mechanical and Aerospace Engineering, King Mongkut' s University of Technology, North Bangkok (Thailand)

    2010-11-15

    High temperature steam gasification is an attractive alternative technology which can allow one to obtain high percentage of hydrogen in the syngas from low-grade fuels. Gasification is considered a clean technology for energy conversion without environmental impact using biomass and solid wastes as feedstock. Sewage sludge is considered a renewable fuel because it is sustainable and has good potential for energy recovery. In this investigation, sewage sludge samples were gasified at various temperatures to determine the evolutionary behavior of syngas characteristics and other properties of the syngas produced. The syngas characteristics were evaluated in terms of syngas yield, hydrogen production, syngas chemical analysis, and efficiency of energy conversion. In addition to gasification experiments, pyrolysis experiments were conducted for evaluating the performance of gasification over pyrolysis. The increase in reactor temperature resulted in increased generation of hydrogen. Hydrogen yield at 1000 C was found to be 0.076 g{sub gas} g{sub sample}{sup -1}. Steam as the gasifying agent increased the hydrogen yield three times as compared to air gasification. Sewage sludge gasification results were compared with other samples, such as, paper, food wastes and plastics. The time duration for sewage sludge gasification was longer as compared to other samples. On the other hand sewage sludge yielded more hydrogen than that from paper and food wastes. (author)

  1. Pharmaceuticals as indictors of sewage-influenced groundwater

    Science.gov (United States)

    Müller, Beate; Scheytt, Traugott; Asbrand, Martin; de Casas, Andrea Mross

    2012-09-01

    A set of human pharmaceuticals enables identification of groundwater that is influenced by sewage and provides information on the time of recharge. As the consumption rates of the investigated pharmaceuticals have changed over time, so too has the composition of the sewage. At the study area, south of Berlin (Germany), irrigation was performed as a method of wastewater clean-up at sewage irrigation farms until the early 1990s. Today, treated wastewater is discharged into the surface-water-stream Nuthegraben. Groundwater and surface-water samples were analyzed for the pharmaceutical substances clofibric acid, bezafibrate, diclofenac, carbamazepine and primidone, the main ions and organic carbon. The pharmaceutical substances were detected at concentrations up to microgram-per-liter level in groundwater and surface-water samples from the Nuthegraben Lowland area and from the former irrigation farms. Concentrations detected in groundwater are generally much lower than in surface water and there is significant variation in the distribution of pharmaceutical concentrations in groundwater. Groundwater influenced by the irrigation of sewage water shows higher primidone and clofibric-acid concentrations. Groundwater influenced by recent discharge of treated sewage water into the surface water shows high carbamazepine concentrations while concentrations of primidone and clofibric acid are low.

  2. Sewage reflects the distribution of human faecal Lachnospiraceae

    Science.gov (United States)

    McLellan, Sandra L.; Newton, Ryan J.; Vandewalle, Jessica L.; Shanks, Orin C.; Huse, Susan M.; Eren, A. Murat; Sogin, Mitchell L.

    2014-01-01

    Summary Faecal pollution contains a rich and diverse community of bacteria derived from animals and humans, many of which might serve as alternatives to the traditional enterococci and Escherichia coli faecal indicators. We used massively parallel sequencing (MPS) of the 16S rRNA gene to characterize microbial communities from wastewater treatment plant (WWTP) influent sewage from 12 cities geographically distributed across the USA. We examined members of the Clostridiales, which included the families Clostridiaceae, Lachnospiraceae and Ruminococcaceae for their potential as sewage indicators. Lachnospiraceae was one of the most abundant groups of faecal bacteria in sewage, and several Lachnospiraceae high-abundance sewage pyrotags occurred in at least 46 of 48 human faecal samples. Clone libraries targeting Clostridium coccoides (C. coccoides) in sewage samples demonstrated that Lachnospiraceae-annotated V6 pyrotags encompassed the previously reported C. coccoides group. We used oligotyping to profile the genus Blautia within Lachnospiraceae and found oligotypes comprised of 24 entropy components that showed patterns of host specificity. These findings suggest that indicators based on Blautia might have the capacity to discriminate between different faecal pollution sources. Development of source-specific alternative indicators would enhance water quality assessments, which leads to improved ecosystem health and reduced human health risk due to waterborne disease. PMID:23438335

  3. The Device Design of a Rural Domestic Sewage Treatment Performance

    Science.gov (United States)

    Liu, Zuhan; Wang, Lili; Deng, Chengzhi

    2017-10-01

    A kind of device for removing pollutant from rural domestic sewage isstudied in this paper, which belongs to the field of sewage treatment technology. The device include anaerobic pool, aerobiotic pool and aerating apparatus. Specifically, the aerobiotic pool is a sealed rectangular body with a rectangular groove on its top cover. The fixed wall is established on one side of the rectangular groove, and the wall is located in the middle of the top cover. The anaerobic pool is opposite to the fixed wall. And there is a aerating apparatusbetween the anaerobic pool and fixed wall, and the apparatus is situated right above the rectangular groove. The design is simple in structure and low in manufacturing cost. The biochemical ratio to the sewage could be improved through the anaerobic pool, and then the sewage is sufficiently aerated by means of natural ventilation and height of water. Theaerated sewage enter into aerobiotic pool, and then the organic matter is degraded into Carbon Dioxide and water under the action of aerobic bacteria, of which function is that the ammonia nitrogen is oxidized into nitrate and nitrite. The water that is far from the aerating apparatus inside of the aerobiotic pool enters into oxygen-deficient environment, and the nitrate is converted into nitrogen. After the effluent is checked qualified, the water is discharged into the drainage ditch or utilized for irrigation.

  4. Gamma irradiation for sewage treatment at US army facilities

    International Nuclear Information System (INIS)

    Van den Berg, A.J.; Hollis, H.D.; Musselman, H.D.; Woodbridge, D.D.

    1975-01-01

    The US Army Corps of Engineers has been sponsoring research for many years on the use of gamma irradiation for disinfection and sterilization of sewage plant effluents. Initial research was directed to laboratory experiments using sterile solutions to determine the effects of gamma irradiation on E. coli, M-pyogenes and M-smegmatis organisms, and on the chemical constituents of sewage such as phenols, surfactants and pesticides. The results of the initial research warranted further study using municipal sewage secondary effluent as test samples. Current research is directed towards investigating the effects of radiation on the constituents of sewage sludge and on the cyst stage of the amoebic protozoa. Consideration has been given by the Corps to the management of waste-waters by disposal on land. Legal and medical reasons dictate that the plant effluents be sterilized before being used as fertilizers and soil conditioners. Gamma radiation from isotopic sources appears to be the best source of sterilizing energy for Army waste-water disposal. The Corps of Engineers is considering the construction of an experimental gamma irradiation pilot facility to validate laboratory experimental work and to establish design criteria for operating plants. The data obtained will provide a basis for performing detailed cost effectiveness studies on gamma irradiation as a method to treat secondary plant effluent. In addition, optimization work will be conducted to determine where in the sewage treatment cycle the use of gamma irradiation will produce the best results in meeting current and anticipated standards. (author)

  5. Urban lifestyle and urban biodiversity

    DEFF Research Database (Denmark)

    Petersen, L. K.; Lyytimäki, J.; Normander, B.

    2007-01-01

    This report is concerned with the relations between lifestyles of urban populations on one hand and protection of biodiversity in urban areas on the other. Urban areas are of importance for the general protection of biodiversity. In the surroundings of cities and within urban sprawls there can...... biodiversity, recreational, educational and other needs. However, uncovered and unsealed space is constantly under pressure for building and infrastructure development in the urban landscape, and the design and usages of urban green structure is a matter of differing interests and expectations. Integrating...... the green needs of urban lifestyle in the planning process does not come by itself. Nor does finding the synergies between urban lifestyle and urban biodiversity. Careful planning including stakeholder involvement is required. In this process various mapping techniques and use of indicators can be most...

  6. Composting of sewage sludge from wastewater treatment plant mixed with a recirculated vegetal fraction in two ratios; Compostaje de fangos de E.D.A.R. en pilas con dos proporciones diferentes de estructurante vegetal recirculado

    Energy Technology Data Exchange (ETDEWEB)

    Plana, R.; Dominguez, J. [Universidad de Vigo (Spain); Aguilera, F.

    2002-07-01

    Due to the next European Directives that are being prepared about the waste management, specially about the organic fraction (U. S. W. sewage sludges, pig slurries, etc.) it will be necessary a previous biological treatment of the waste before spreading it on the soil. the current work studies the windrow composting of sewage sludge from an urban wastewater treatment plant mixed with a recirculated vegetal fraction in two different volumetric ratios (2:1 and 1:1). Temperature and oxygen consumption are measured to control the composting process, as well as the turning frequency and the quantity of products that is degradated. Although the process reaches thermofilic temperatures in both windrow, it is showed that in the 2:1 ratio more sludge is proportionally degradated. An economic study of the composting of this sewage sludge in different composting methods (dynamic and semi static) was made. (Author) 7 refs.

  7. Changes in bacterial and eukaryotic communities during sewage decomposition in Mississippi River water

    Science.gov (United States)

    Microbial decay processes are one of the mechanisms whereby sewage contamination is reduced in the environment. This decomposition process involves a highly complex array of bacterial and eukaryotic communities from both sewage and ambient waters. However, relatively little is kn...

  8. Joint NRC/EPA Sewage Sludge Radiological Survey: Survey Design & Test Site Results

    Science.gov (United States)

    This report contains the results of a radiological survey of nine publicly POTWs around the country, which was commissioned by the Sewage Sludge Subcommittee, to determine whether and to what extent radionuclides concentrate in sewage treatment wastes.

  9. Environmentally compatible sewage sludge disposal; Umweltgerechte Klaerschlammentsorgung

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, J. [Technische Univ. Braunschweig (Germany). Inst. fuer Mechanische Verfahrenstechnik; Schwedes, J. [Technische Univ. Braunschweig (Germany). Inst. fuer Mechanische Verfahrenstechnik

    1997-09-01

    Cleaning of municipal and industrial waste water is done by means of biological processes: micro-organisms degrade pollutants. The resulting products are, besides cleaned waste water, sewage sludge and surplus sludge. Their disposal involves ecological and economic problems. One approach to their partial disposal is their degradation in a digester. Approximately one half of the organic substance is converted by anaerobic bacteria into energy-rich biogas. Optimization of this digestion process accelerates the anaerobic degradation process, increases the accruing amount of digester gas and reduces the volume of digested sludge to be disposed of. With these objectives, the Institute fuer Mechanische Verfahrenstechnik is conducting research into the mechanical treatment of micro-organisms remaining in surplus sludge by means of different treatment devices. The project is sponsored under the programme of the Deutsche Forschungsgemeinschaft DFG ``Biological processes with dispersive solids``. Mechanical treatment renders the cell constituents exploitable to anaerobic bacteria; the resulting sludge degradation is more rapid and more complete. (orig./ABI) [Deutsch] Zur Reinigung haeuslicher und industrieller Abwaesser werden biologische Prozesse eingesetzt. Dabei sorgen Mikroorganismen fuer den Abbau der Verunreinigungen. Neben dem gereinigten Abwasser fallen Primaer- und Ueberschussschlamm an, deren Entsorgung oekologische und oekonomische Probleme verursacht. Ein Weg zur partiellen Beseitigung dieser Klaerschlaemme ist ihr Abbau in einem Faulbehaelter. Dabei wird etwa die Haelfe der organischen Substanz durch anaerobe Bakterien zu einem energiereichen Biogas umgewandelt. Eine Optimierung dieses Faulprozesses beinhaltet: 1. Beschleunigung des anaeroben Abbauprozesses, 2. Erhoehung der anfallenden Faulgasmenge und 3. Reduzierung der zu entsorgenden Faulschlammenge. Mit diesen Zielsetzungen wird am Institut fuer Mechanische Verfahrenstechnik im Rahmen der DFG

  10. Bioremediation of Acidic and Metalliferous Drainage (AMD) through organic carbon amendment by municipal sewage and green waste.

    Science.gov (United States)

    McCullough, Clint D; Lund, Mark A

    2011-10-01

    Pit lakes (abandoned flooded mine pits) represent a potentially valuable water resource in hot arid regions. However, pit lake water is often characterised by low pH with high dissolved metal concentrations resulting from Acidic and Metalliferous Drainage (AMD). Addition of organic matter to pit lakes to enhance microbial sulphate reduction is a potential cost effective remediation strategy. However, cost and availability of suitable organic substrates are often limiting. Nevertheless, large quantities of sewage and green waste (organic garden waste) are often available at mine sites from nearby service towns. We treated AMD pit lake water (pH 2.4) from tropical, North Queensland, Australia, with primary-treated sewage sludge, green waste, and a mixture of sewage and green waste (1:1) in a controlled microcosm experiment (4.5 L). Treatments were assessed at two different rates of organic loading of 16:1 and 32:1 pit water:organic matter by mass. Combined green waste and sewage treatment was the optimal treatment with water pH increased to 5.5 in only 145 days with decreases of dissolved metal concentrations. Results indicated that green waste was a key component in the pH increase and concomitant heavy metal removal. Water quality remediation was primarily due to microbially-mediated sulphate reduction. The net result of this process was removal of sulphate and metal solutes to sediment mainly as monosulfides. During the treatment process NH(3) and H(2)S gases were produced, albeit at below concentrations of concern. Total coliforms were abundant in all green waste-treatments, however, faecal coliforms were absent from all treatments. This study demonstrates addition of low-grade organic materials has promise for bioremediation of acidic waters and warrants further experimental investigation into feasibility at higher scales of application such as pit lakes. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  11. Urban physics

    NARCIS (Netherlands)

    Blocken, B.J.E.

    2012-01-01

    Urban Physics is the multiscale and interdisciplinary research area dealing with physical processes in urban environments that influence our everyday health, comfort and productivity. It involves disciplines ranging from mesoscale meteorology to human thermophysiology. The introductory lecture

  12. Urban Times

    DEFF Research Database (Denmark)

    Nielsen, Morten

    2017-01-01

    This is a proposed special issue with six thematic articles by different contributors on 'urban times' edited by me.......This is a proposed special issue with six thematic articles by different contributors on 'urban times' edited by me....

  13. Soil Microbial Functional and Fungal Diversity as Influenced by Municipal Sewage Sludge Accumulation

    OpenAIRE

    Frąc, Magdalena; Oszust, Karolina; Lipiec, Jerzy; Jezierska-Tys, Stefania; Nwaichi, Eucharia Oluchi

    2014-01-01

    Safe disposal of municipal sewage sludge is a challenging global environmental concern. The aim of this study was to assess the response of soil microbial functional diversity to the accumulation of municipal sewage sludge during landfill storage. Soil samples of a municipal sewage sludge (SS) and from a sewage sludge landfill that was 3 m from a SS landfill (SS3) were analyzed relative to an undisturbed reference soil. Biolog EcoPlatesTM were inoculated with a soil suspension, and the Avera...

  14. A Feasibility Study of Power Generation from Sewage Using a Hollowed Pico-Hydraulic Turbine

    OpenAIRE

    Tomomi Uchiyama; Satoshi Honda; Tomoko Okayama; Tomohiro Degawa

    2016-01-01

    This study is concerned with the feasibility of power generation using a pico-hydraulic turbine from sewage flowing in pipes. First, the sewage flow rate at two connection points to the Toyogawa River-Basin Sewerage, Japan, was explored for over a year to elucidate the hydraulic energy potential of the sewage. Second, the performance of the pico-hydraulic turbine was investigated via laboratory experiments that supposed the turbine to be installed in the sewage pipe at the connection points. ...

  15. Assessing sewage impact in a South-West Atlantic rocky shore intertidal algal community.

    Science.gov (United States)

    Becherucci, Maria Eugenia; Santiago, Lucerito; Benavides, Hugo Rodolfo; Vallarino, Eduardo Alberto

    2016-05-15

    The spatial and seasonal variation of the specific composition and community parameters (abundance, diversity, richness and evenness) of the intertidal algal assemblages was studied at four coastal sampling sites, distributed along an environmental gradient from the sewage water outfall of Mar del Plata, Buenos Aires, Argentina. Two of them were located close to the sewage outfall (sewage outfall impact. Ulva spp. did not reflect the typical pattern observed for other sewage pollution areas. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Sources and transformations of anthropogenic nitrogen along an urban river–estuarine continuum

    Directory of Open Access Journals (Sweden)

    M. J. Pennino

    2016-11-01

    Full Text Available Urbanization has altered the fate and transport of anthropogenic nitrogen (N in rivers and estuaries globally. This study evaluates the capacity of an urbanizing river–estuarine continuum to transform N inputs from the world's largest advanced (e.g., phosphorus and biological N removal wastewater treatment facility. Effluent samples and surface water were collected monthly along the Potomac River estuary from Washington D.C. to the Chesapeake Bay over a distance of 150 km. In conjunction with box model mass balances, nitrate stable isotopes and mixing models were used to trace the fate of urban wastewater nitrate. Nitrate concentrations and δ15N-NO3− values were higher down-estuary from the Blue Plains wastewater outfall in Washington D.C. (2.25 ± 0.62 mg L−1 and 25.7 ± 2.9 ‰, respectively compared to upper-estuary concentrations (1.0 ± 0.2 mg L−1 and 9.3 ± 1.4 ‰, respectively. Nitrate concentration then decreased rapidly within 30 km down-estuary (to 0.8 ± 0.2 mg L−1, corresponding to an increase in organic nitrogen and dissolved organic carbon, suggesting biotic uptake and organic transformation. TN loads declined down-estuary (from an annual average of 48 000 ± 5000 kg day−1 at the sewage treatment plant outfall to 23 000 ± 13 000 kg day−1 at the estuary mouth, with the greatest percentage decrease during summer and fall. Annually, there was a 70 ± 31 % loss in wastewater NO3− along the estuary, and 28 ± 6 % of urban wastewater TN inputs were exported to the Chesapeake Bay, with the greatest contribution of wastewater TN loads during the spring. Our results suggest that biological transformations along the urban river–estuary continuum can significantly transform wastewater N inputs from major cities globally, and more work is necessary to evaluate the potential of organic nitrogen and carbon to contribute to eutrophication and hypoxia.

  17. Removal and factors influencing removal of sulfonamides and trimethoprim from domestic sewage in constructed wetlands.

    Science.gov (United States)

    Dan A; Yang, Yang; Dai, Yu-Nv; Chen, Chun-Xing; Wang, Su-Yu; Tao, Ran

    2013-10-01

    Twelve pilot-scale constructed wetlands with different configurations were set up in the field to evaluate the removal and factors that influence removal of sulfonamides (sulfadiazine, sulfapyridine, sulfacetamide, sulfamethazine and sulfamethoxazole) and trimethoprim from domestic sewage. The treatments included four flow types, three substrates, two plants and three hydraulic loading rates across two seasons (summer and winter). Most target antibiotics were efficiently removed by specific constructed wetlands; in particular, all types of constructed wetlands performed well for the degradation of sulfapyridine. Flow types were the most important influencing factor in this study, and the best removal of sulfonamides was achieved in vertical subsurface-flow constructed wetlands; however, the opposite phenomenon was found with trimethoprim. Significant relationships were observed between antibiotic degradation and higher temperature and redox potential, which indicated that microbiological pathways were the most probable degradation route for sulfonamides and trimethoprim in constructed wetlands. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Effects of cadmium on the performance and microbiology of laboratory-scale lagoons treating domestic sewage.

    Science.gov (United States)

    Bonnet, J L; Bohatier, J; Pépin, D

    1999-06-01

    Two experiments were performed to assess the impact of cadmium on the sewage lagoon wastewater treatment process. For each one, three laboratory-scale pilot plants with one tank receiving the same raw effluent were used; one plant served as control and the other two were contaminated once only with cadmium. In the first study, the effects of a shock load of two concentrations of cadmium chloride (60 and 300 micrograms/l) on the plant performance, microbial populations (protists and bacteria) and enzyme activities were determined. Initially, most of the performance parameters were affected concentration-dependently. A reduction in the protist population density and some influence on the total bacterial population were observed, and the potential enzymatic activities were also modified. A second experiment with a lower cadmium concentration (30 micrograms/l), supplied as chloride or sulphate, still perturbed most of the parameters studied, and the effects of the two cadmium salts were identical.

  19. Bioleaching of heavy metals from sewage sludge using Acidithiobacillus thiooxidans

    Science.gov (United States)

    Wen, Ye-Ming; Lin, Hong-Yan; Wang, Qing-Ping; Chen, Zu-Liang

    2010-11-01

    Acidithiobacillus thiooxidans was isolated from sewage sludge using the incubation in the Waksman liquor medium and the inoculation in Waksman solid plate. It was found that the optimum conditions of the bioleaching included solid concentration 2%, sulfur concentration 5 gṡL-1 and cell concentration 10%. The removal efficiency of Cr, Cu, Pb and Zh in sewage sludge, which was obtained from waste treatment plant, Jinshan, Fuzhou, was 43.65%, 96.24%, 41.61% and 96.50% in the period of 4˜10 days under the optimum conditions, respectively. After processing using the proposed techniques, the heavy metals in sewage sludge did meet the requirement the standards of nation.

  20. Recycling of sewage in Swedish municipalities - Policy implications

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, H

    1998-12-31

    The construction of sewage treatment plants, which increased dramatically during the sixties in Sweden, was based on the idea that sewage is a waste, despite the fact that it contains considerable amounts of nourishment. Environmental research today, focuses more and more on recycling and on the potential resource inherent in sewage. This chapter deals with how to manage a change from problem elimination to recycling of resources, and discuss such from an institutional perspective. A shift towards recycling implies a shift of techniques, decision-makers and process strategies. Implementation of recycling will need strategic principles, and thereby results from research focusing common property resource management can be used in the policy process 32 refs, 5 figs

  1. Recycling of sewage in Swedish municipalities - Policy implications

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, H.

    1997-12-31

    The construction of sewage treatment plants, which increased dramatically during the sixties in Sweden, was based on the idea that sewage is a waste, despite the fact that it contains considerable amounts of nourishment. Environmental research today, focuses more and more on recycling and on the potential resource inherent in sewage. This chapter deals with how to manage a change from problem elimination to recycling of resources, and discuss such from an institutional perspective. A shift towards recycling implies a shift of techniques, decision-makers and process strategies. Implementation of recycling will need strategic principles, and thereby results from research focusing common property resource management can be used in the policy process 32 refs, 5 figs

  2. Urban streets

    NARCIS (Netherlands)

    Schönfeld, von Kim Carlotta; Bertolini, Luca

    2017-01-01

    Today's urban streets are usually planned for purposes of mobility: pedestrians, as well as a variety of vehicles such as cars, trucks, and sometimes bicycles, are usually factored into an urban street plan. However, urban streets are also increasingly recognized as public spaces, accommodating

  3. Impact of urban waste water treatment on sludge utilization and disposal with special emphasis on thermal treatment

    International Nuclear Information System (INIS)

    Gammeltoft, P.

    1993-01-01

    The acceptance of the European Communities Directive 9/271/CEE concerning urban waste water treatment by all the EC Member States will result in a sewage sludge production increase of 2 to 3 times the actual amounts (for the year 2000 the forecast is about 30 million tonnes per year). All the traditional sewage sludge treatment methods (agricultural, disposal, compost, thermal treatment) entail costs which are always increasing because of the stricter requirements; in addition EC policy is oriented towards the reduction of the quantity of sludge production. In some situations, drying and subseque incineration may thus be the only practicable method of disposal, particularly, in very large urban agglomerations

  4. Experience with a pilot plant for the irradiation of sewage sludge: Results on the effect of differently treated sewage sludge on plants and soil

    International Nuclear Information System (INIS)

    Suess, A.; Rosopulo, A.; Borchert, H.; Beck, Th.; Bauchhenss, J.; Schurmann, G.

    1975-01-01

    Since hygienization of sewage sludge will be important for an agricultural application it is necessary to study the effect of differently treated sewage sludge on plants and soil. In bean and maize experiments in 1973 and 1974 it was found that the treatment of sewage sludge is less important than soil properties and water capacity. Analysis on the efficiency of nutrients, minor elements and heavy metals from differently treated sewage sludge to plants were performed. Microbiological greenhouse studies indicated that there is a distinct tendency for different reactions, that irradiated sewage sludge gives a slightly better effect than untreated sludge, while the heat-treated sewage sludge indicates always a decrease, especially with the increase of applied amounts (respiration, protease and nitrification). In the field experiments there were almost no differences between untreated and irradiated sewage sludge, whereas there was always a smaller microbial activity after application of heat-treated sewage sludge. Studies on soil fauna (especially on Collemboles and Oribatidae) in the field trials indicate the influences of abiotic factors on the different locations. Besides these influences there was a decrease in the number of Collemboles and mites (in comparison with a normal fertilized plot) on the plots with 800 m 3 /ha treated sewage sludge. There was a remarkably large decrease in the plots with irradiated sewage sludge after an application of 800 m 3 /ha. Depending on the soil type, physical and chemical studies indicated an increase in the effective field capacity after the application of sewage sludge, and sometimes the best effects occurred with irradiated sewage sludge. Relative high aggregate values were observed (6-2, 6-5 mm diameter) in the plots with irradiated sewage sludge. (author)

  5. Occurrence and ecological risk assessment of emerging organic chemicals in urban rivers

    NARCIS (Netherlands)

    Peng, Feng Jiao; Pan, Chang Gui; Zhang, Min; Zhang, Nai Sheng; Windfeld, Ronja; Salvito, Daniel; Selck, Henriette; Brink, Van den Paul J.; Ying, Guang Guo

    2017-01-01

    Urban rivers may receive contamination from various sources including point sources like domestic sewage and nonpoint sources (e.g., runoff), resulting in contamination with various chemicals. This study investigated the occurrence of emerging organic contaminants (3 endocrine disrupting

  6. Waste water as a source for secondary resources and linkage to other urban systems

    NARCIS (Netherlands)

    Agudelo Vera, C.M.; Mels, A.R.; Rijnaarts, H.H.M.

    2010-01-01

    Urban metabolism studies have shown that, in terms of sheer mass, water is the largest and the most vital component. Population growth and higher living standards will cause ever increasing demands for good quality municipal and industrial water, and ever increasing sewage flows within a limited

  7. Hydraulic conductivity and soil-sewage sludge interactions

    Directory of Open Access Journals (Sweden)

    Silvio Romero de Melo Ferreira

    2011-10-01

    Full Text Available One of the main problems faced by humanity is pollution caused by residues resulting from the production and use of goods, e.g, sewage sludge. Among the various alternatives for its disposal, the agricultural use seems promising. The purpose of this study was to evaluate the hydraulic conductivity and interaction of soil with sandy-silty texture, classified as Spodosols, from the Experimental Station Itapirema - IPA, in Goiana, state of Pernambuco, in mixtures with sewage sludge from the Mangueira Sewage Treatment Station, in the city of Recife, Pernambuco at rates of 25, 50 and 75 Mg ha-1. Tests were conducted to let water percolate the natural saturated soil and soil-sludge mixtures to characterize their physical, chemical, and microstructural properties as well as hydraulic conductivity. Statistical data analysis showed that the presence of sewage sludge in soils leads to an increase of the < 0.005 mm fraction, reduction in real specific weight and variation in optimum moisture content from 11.60 to 12.90 % and apparent specific dry weight from 17.10 and 17.50 kN m-3. In the sludge-soil mixture, the quartz grains were covered by sludge and filling of the empty soil macropores between grains. There were changes in the chemical characteristics of soil and effluent due to sewage sludge addition and a small decrease in hydraulic conductivity. The results indicate the possibility that soil acidity influenced the concentrations of the elements found in the leachate, showing higher levels at higher sludge doses. It can be concluded that the leaching degree of potentially toxic elements from the sewage sludge treatments does not harm the environment.

  8. Response of rice to nitrogenous fertilizer and irradiated sewage sludge

    International Nuclear Information System (INIS)

    Azam, F.; Lodhi, A.; Sajjad, M.H.

    2003-01-01

    A greenhouse pot experiment was conducted to study the effect of Gamma-irradiated sewage sludge, applied alone or along with /sup 15/N-labelled ammonium sulphate (1.0 atom % /sup 15/N excess), on rice yield and N uptake. Six-kg portions of a clay loam were amended wit sewage sludge to obtain N addition rates of 30, 60, 90 and 120 mg kg/sub -1/ soil. In other treatments nitrogen was applied at 120 mg kg/sup -1/ as /sup 15/N-labelled ammonium sulphate or 120 mg kg/sub -1/ as /sup 15/NH/sub 4/-N + sludge-N in the ratios of 1:3, 1:1, or 3:1. All the treatments were given before transplanting rice. Three healthy seedlings (4-week old) of rice (Oryza sativa L., var. Bas-Pak) were transplanted pot/sup -1/ and the plants harvested at maturity. Application of sewage sludge caused a significant improvement in rice yield. Grain yield increased by 188% at sludge-N of 120 mg N kg/sup -1/. The yield benefit at similar rate of fertilizer N was 304%, the increase being more at higher rates of application. The increase in rice yield was dependent on uptake of N and sewage sludge significantly improved the availability of N to the plants. The additional plant N in sludge treated soil was partially attributable to enhanced mineralization of soil N and N/sub 2/ fixation by free living microorganisms. Application of inorganic N led to a significant increase in the availability of N to plants from soil organic matter and sewage sludge. Results of combined application suggested that substantial savings of fertilizer N can be made by using sewage sludge on rice-fields. (author)

  9. Health status and bioremediation capacity of wild freshwater mussels (Diplodon chilensis) exposed to sewage water pollution in a glacial Patagonian lake.

    Science.gov (United States)

    Bianchi, Virginia A; Castro, Juan M; Rocchetta, Iara; Bieczynski, Flavia; Luquet, Carlos M

    2014-04-01

    Deleterious effects on health and fitness are expected in mussels chronically exposed to sewage water pollution. Diplodon chilensis inhabiting SMA, an area affected by untreated and treated sewage water, shows increased hemocyte number and phagocytic activity, while bacteriolytic and phenoloxidase activities in plasma and reactive oxygen species production in hemocytes are lower compared to mussels from an unpolluted area (Yuco). There are not differences in cell viability, lysosomal membrane stability, lipid peroxidation and total oxygen scavenging capacity between SMA and Yuco mussels' hemocytes. Energetic reserves and digestive gland mass do not show differences between groups; although the condition factor is higher in SMA than in Yuco mussels. Gills of SMA mussels show an increase in mass and micronuclei frequency compared to those of Yuco. Mussels from both sites reduce bacterial loads in polluted water and sediments, improving their quality with similar feeding performance. These findings suggest that mussels exposed to sewage pollution modulate physiological responses by long-term exposure; although, gills are sensitive to these conditions and suffer chronic damage. Bioremediation potential found in D. chilensis widens the field of work for remediation of sewage bacterial pollution in water and sediments by filtering bivalves. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. New process controls in the co-fermentation of organic waste and municipal sewage sludge; Neue Verfahrensfuehrungen bei der Co-Vergaerung von Bioabfaellen und kommunalen Klaerschlaemmen

    Energy Technology Data Exchange (ETDEWEB)

    Schaepers, D.; Schierholt, M.; Buer, T.; Risse, H. [Technische Hochschule Aachen (DE). Inst. fuer Siedlungswasserwirtschaft (ISA)

    1999-07-01

    For the co-fermentation of organic waste and sewage sludge in digester towers at municipal sewage treatment plant, mainly single-stage processes have so far been studied or are in use in part. Within the framework of a project sponsored by the foundation Oswald-Schulze-Stiftung, the use of a two-stage mode of operation (thermophilic/mesophilic) for co-fermenting organic waste and sewage sludge was investigated. By adding organic waste to the digester content, biogas production per reactor volume was more than doubled in comparison with exclusive sewage sludge fermentation. Because of the thermophilic stage for the conditioning of organic waste, specific biogas yield for an organic load of 1.5 kg organic dry residue TR/m{sup 3*}d was slightly enhanced in comparison with single-stage co-fermentation. (orig.) [German] Zur Co-Vergaerung von Bioabfaellen und Klaerschlamm in Faultuermen kommunaler Klaeranlagen werden bislang hauptsaechlich einstufige Verfahren untersucht und teilweise eingesetzt. Im Rahmen eines von der Oswald-Schulze-Stiftung gefoerderten Projektes wurde der Einsatz einer 2-stufigen Betriebsweise (thermophil/mesophil) bei der Co-Vergaerung von Bioabfaellen und Klaerschlamm untersucht. Die Biogasproduktion pro Reaktorvolumen konnte durch die Zugabe von Bioabfall in die Faulbehaelter gegenueber der reinen Klaerschlammfaulung mehr als verdoppelt werden. Durch die thermophile Stufe zur Vorbehandlung der Bioabfaelle konnte die spezifische Biogasausbeute bei einer organischen Raumbelastung von 1,5 kg o TR/m{sup 3*}d gegenueber der 1-stufigen Co-Vergaerung leicht erhoeht werden. (orig.)

  11. Sewage sludge treatment and disposal. Experiences and perspectives; Klaerschlammbehandlung und -entsorgung. Erfahrungen und Perspektiven

    Energy Technology Data Exchange (ETDEWEB)

    Dichtl, N.; Mueller, J. [comps.] [Technische Univ. Braunschweig (Germany). Inst. fuer Siedlungswasserwirtschaft

    1997-09-01

    Topics of the proceedings are: sewage sludge treatment and sewage sludge disposal by means of: thermal treatment, fermentation, composting, wet oxidation, hydrolysis, disposal in agriculture, economical aspects of sewage sludge treatment. This book deals with theoretical aspects and practical examples. (SR)

  12. 33 CFR 151.79 - Operating requirements: Discharge of sewage within Antarctica.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Operating requirements: Discharge of sewage within Antarctica. 151.79 Section 151.79 Navigation and Navigable Waters COAST GUARD... Pollution and Sewage § 151.79 Operating requirements: Discharge of sewage within Antarctica. (a) A vessel...

  13. Study of heavy metal in sewage sludge and in Chinese cabbage ...

    African Journals Online (AJOL)

    The study was performed to investigate the heavy metal content and availability for crops in sewage sludge and its accumulation in Chinese cabbage grown in sewage sludge amended soil. We determined the total and chemical fraction of As, Cr, Cd, Pb, Ni, Cu, Zn, Fe, Mg and Mn in sewage sludge and the total content of ...

  14. Vivianite as an important iron phosphate precipitate in sewage treatment plants

    NARCIS (Netherlands)

    Wilfert, P.K.; Mandalidis, A.; Dugulan, A.I.; Goubitz, K.; Korving, L; Temmink, H; Witkamp, G.J.; van Loosdrecht, Mark C.M.

    2016-01-01

    Iron is an important element for modern sewage treatment, inter alia to remove phosphorus from sewage. However, phosphorus recovery from iron phosphorus containing sewage sludge, without incineration, is not yet economical. We believe, increasing the knowledge about iron-phosphorus speciation in

  15. 78 FR 34918 - Direct Final Approval of Sewage Sludge Incinerators State Plan for Designated Facilities and...

    Science.gov (United States)

    2013-06-11

    ... Approval of Sewage Sludge Incinerators State Plan for Designated Facilities and Pollutants; Indiana AGENCY... to control air pollutants from ``Sewage Sludge Incinerators'' (SSI). The Indiana Department of... unit,'' in part, as any device that combusts sewage sludge for the purpose of reducing the volume of...

  16. 33 CFR 159.309 - Limitations on discharge of treated sewage or graywater.

    Science.gov (United States)

    2010-07-01

    ... treated sewage or graywater. 159.309 Section 159.309 Navigation and Navigable Waters COAST GUARD... Certain Alaskan Waters by Cruise Vessel Operations § 159.309 Limitations on discharge of treated sewage or graywater. (a) No person shall discharge treated sewage or graywater from a cruise vessel into the...

  17. A COMPREHENSIVE STUDY OF HOURLY AND DAILY SEWAGE FLOW RATES IN FLORIDA PUBLIC SCHOOLS.

    Science.gov (United States)

    FOGARTY, WILLIAM J.; REEDER, MILTON E.

    A DETERMINATION OF THE HOURLY AND DAILY SEWAGE FLOW RATES IN FLORIDA PUBLIC SCHOOLS WAS MADE TO IDENTIFY THE FLOW CHARACTERISTICS AND TO PROVIDE A MORE PRECISE BASIS FOR THE ESTABLISHMENT OF DESIGN CRITERIA FOR SEWAGE DISPOSAL FACILITIES IN SCHOOLS. WATER FLOW DATA WAS COLLECTED FOR 158 SCHOOLS AND SEWAGE FLOW DATA FROM 42 SCHOOLS. THE FINDINGS…

  18. 18 CFR 1304.403 - Marina sewage pump-out stations and holding tanks.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Marina sewage pump-out... OTHER ALTERATIONS Miscellaneous § 1304.403 Marina sewage pump-out stations and holding tanks. All pump... purposes of inspection; (i) Spill-proof features adequate for transfer of sewage from all movable floating...

  19. 7 CFR 1780.63 - Sewage treatment and bulk water sales contracts.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Sewage treatment and bulk water sales contracts. 1780..., Designing, Bidding, Contracting, Constructing and Inspections § 1780.63 Sewage treatment and bulk water sales contracts. Owners entering into agreements with private or public parties to treat sewage or...

  20. Detection and distribution of rotavirus in raw sewage and creeks in Sao Paulo, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Mehnert, D.U.; Stewien, K.E. (Univ. of Sao Paulo (Brazil))

    1993-01-01

    Rotavirus invection is an important cause of hospitalization and mortality of infants and children in developing countries, especially where the water supply and sewage disposal systems are in precarious conditions. This report describes the detection, quantitation, and distribution of rotaviruses in domestic sewage and sewage polluted creeks in the city of San Paulo. 22 refs., 1 fig., 3 tabs.

  1. Production of glass-ceramic materials obtained from sewage sludge treatment plant for urban wastewater in El-Sadat city (Egypt); Materiales vitroceramicos a partir de lodos procedentes de una estacion de depuracion de aguas residuales urbanas (en la Ciudad de El-Sadat, Egipto).

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Valles, M.; Aly, M. H.; El-Fadaly, E.; Hafez, H. S.; Nogues, J.; Martinez, S.

    2011-07-01

    Urban wastewater security is a source of significant volumes of sludge which is to be managed. This paper presents the possibility of applying a management process based on vitrification and by which, in addition to inert contaminants in sludge, you get a ceramic material with a significant added value. As a base of different analysis of the sludges, chemical (XRF), mineralogical (XRD) and thermal (DTA-TG), we obtain the original glass composition and its energy. By DTATG, dilatometry and SEM, it was determined the temperature of maximum nucleation rate, growth temperature and the morphology and size of developed nuclei, in this case are nano scale. Briefly, it was found as the management of municipal solid waste by vitrification as an alternative to landfills and incineration. (Author)

  2. Urban architecture in urban renewal

    DEFF Research Database (Denmark)

    Holmgren, Steen; Svensson, Ole

    2001-01-01

    and without obvious architectural value. These issues raise pertinent questions: what urban architectural problems and qualities exist in the complex, inner suburbs? What differences exist between professionals' and residents' perceptions and assessments of urban architecture? How can a shared language...

  3. Ensuring Sustainable Development through Urban Planning in Pakistan

    Directory of Open Access Journals (Sweden)

    Mohammad Qasim

    2013-04-01

    Full Text Available Urban planning includes land use management and environmental change. It makes arrangement for community facilities and services. Since, sustainable development has been included as a vital end product of all planning goals it also provides for balanced use of land, housing and transportation and better quality of life. Present urban planning in Pakistan is not ensuring sustainable development in Pakistan. This is tested through the case study of master planning in Rawalpindi and its implementation through housing schemes in Rawalpindi, Pakistan. Large portions of provisions of master plans are not implemented. This paper explains how the urban planning will be made enabled to ensure sustainable development in Pakistan. Six numbers of housing schemes and two squatter settlements have been surveyed through questionnaires, secondary data, the opinions of the experts from related fields and site observations. Amenities and social services at far distance, very less green area, Less quantity and bad quality of water, absence of comprehensive solid waste management and sewage disposal system and nontreatment of solid waste, effluent and sewage, prevalent unhygienic conditions and air and water pollution are the existing factors effecting the sustainability. There is a need to revisit the urban planning and a comprehensive Urban and Environment Planning Law at national level and at provincial level is recommended to enable the urban planning to ensure the sustainable development in Pakistan

  4. Ensuring sustainable development through urban planing in pakistan

    International Nuclear Information System (INIS)

    Qasim, M.; Zaidi, S.S.U.

    2013-01-01

    Urban planning includes land use management and environmental change. It makes arrangement for community facilities and services. Since, sustainable development has been included as a vital end product of all planning goals it also provides for balanced use of land, housing and transportation and better quality of life. Present urban planning in Pakistan is not ensuring sustainable development in Pakistan. This is tested through the case study of master planning in Rawalpindi and its implementation through housing schemes in Rawalpindi, Pakistan. Large portions of provisions of master plans are not implemented. This paper explains how the urban planning will be made enabled to ensure sustainable development in Pakistan. Six numbers of housing schemes and two squatter settlements have been surveyed through questionnaires, secondary data, the opinions of the experts from related fields and site observations. Amenities and social services at far distance, very less green area, Less quantity and bad quality of water, absence of comprehensive solid waste management and sewage disposal system and non- treatment of solid waste, effluent and sewage, prevalent unhygienic conditions and air and water pollution are the existing factors effecting the sustainability. There is a need to revisit the urban planning and a comprehensive Urban and Environment Planning Law at national level and at provincial level is recommended to enable the urban planning to ensure the sustainable development in Pakistan. (author)

  5. Life cycle assessment of sewage sludge management: A review

    DEFF Research Database (Denmark)

    Yoshida, Hiroko; Christensen, Thomas Højlund; Scheutz, Charlotte

    2013-01-01

    In this article, 35 published studies on life cycle assessment (LCA) of sewage sludge were reviewed for their methodological and technological assumptions. Overall, LCA has been providing a flexible framework to quantify environmental impacts of wastewater and sewage sludge treatment and disposal...... and how they were estimated in the analysis. In order to reduce these choice uncertainties, consolidation of the modelling approach in the following area are recommended: quantification of fugitive gas emissions and modelling of disposal practices. Besides harmonization of the key technical assumptions...

  6. Reasonable management plan of sludge in sewage disposal plant

    Energy Technology Data Exchange (ETDEWEB)

    Yum, Kyu Jin; Koo, Hyun Jung [Korea Environment Institute, Seoul (Korea)

    1998-12-01

    The compost method, which is widely used as a sewage disposal recycling in Korea, is now basically impossible to recycle sludge to compost by the Ministry of Agriculture and Forestry announcement. Therefore, the disposal of sludge will be much harder with reducing the amount of sludge used as compost. The amount of sludge other than using as compost is very small, so the development of various sludge recycling and use will be needed with regulations. This study was implemented to help the establishment of sewage sludge recycling policy in Korea. 30 refs., 17 figs., 58 tabs.

  7. Borehole drilling for sewage disposal at Asuka Station, East Antarctica

    OpenAIRE

    Ishizawa,Kenji; Takahashi,Akiyoshi

    1994-01-01

    A borehole for sewage disposal was drilled at Asuka Station (71°31′34″S, 24°08′17″E, 930m a. s. l.) in January 1987. The borehole, 400mm in diameter and 27.5m in depth, was drilled 50m distant from the main hut using a steam drilling system. The drilling speed was 4m/h between the snow surface and 20m depth. The total amount of kerosene used for melting snow and steam generation was 110/. Sewage stored in the tank was directed to the borehole through a heated pipe. The cumulative amount of se...

  8. Future of sewage sludge in disposal; Klaerschlammentsorgung. Quo vadis?

    Energy Technology Data Exchange (ETDEWEB)

    Wiechmann, Benjamin [Umweltbundesamt, Dessau (Germany). Fachgebiet III 2.4 - Abfalltechnik, Abfalltechniktransfer

    2013-06-01

    The thermal treatment of sewage sludge is changing continuously. In the future, the disposal of sewage sludge is framed and will be adjust by the idea of resource saving. Simultaneously due the amendment of the 17th BImSchV emission control will be encouraged. Although, more than a quarter of the upcoming sludge is incinerated in mono-incineration plants, this amount should be increased. Therefore, it is necessary to build up new capacities of mono-incineration plants. The legal and strategic framework which has an influence on the combustion of sludge will be examined in this paper. (orig.)

  9. Irradiation treatment of sewage sludge: History and prospects

    International Nuclear Information System (INIS)

    Bao Borong; Wu Minghong; Zhou Ruimin; Zhu Jinliang

    1998-01-01

    This paper first reviews the history of irradiation treatment of sewage sludge in the world. The first sludge irradiation plant was built in Geiselbullach, West Germany in 1973 and used 60 Co as irradiation source. Since then, many sludge irradiators were constructed in U.S.A., India, Japan, Canada, Poland, etc., which used 60 Co, 137 Cs or electron beam as irradiation sources. The paper then describes some basic research on irradiation treatment of sewage sludge including optimization of irradiation parameters, synergistic effect of radiation with heat, oxygenation, irradiation-composting and potential applications of treated sludge. Some proposals have been suggested for further development of this technology in the future

  10. Phosphorus recovery from sewage sludge by an electrokinetic process

    DEFF Research Database (Denmark)

    Ribeiro, A.B.; Couto, N.; Mateus, E.P.

    to supply P for the next ca. 80 years. Additionaly, the quality of this raw material has deteriorated due to contamination, which has increased processing costs of mineral P fertilizers. The recovery of nutrients, like P, from secondary resources urges. Sewage sludge (SS) and sewage sludge ash (SSA) from...... waste water treatment plants (WWTP) may contain contaminants or unwanted elements regarding specific applications, but they also contain secondary resources of high value. Using these ash as a P resource, while removing the contaminants, seems a sustainable option. The electrokinetic (EK) process can....... This communication aims to discuss preliminary results of the feasibility of EK process to recover P from WWTP target wastes....

  11. Comparative short-term effects of sewage sludge and its biochar on soil properties, maize growth and uptake of nutrients on a tropical clay soil in Zimbabwe

    Institute of Scientific and Technical Information of China (English)

    Willis Gwenzi; Moreblessing Muzava; Farai Mapanda; Tonny P Tauro

    2016-01-01

    Soil application of biochar from sewage could potentialy enhance carbon sequestration and close urban nutrient balances. In sub-Saharan Africa, comparative studies investigating plant growth effect and nutrients uptake on tropical soils amended with sewage sludge and its biochar are very limited. A pot experiment was conducted to investigate the effects of sewage sludge and its biochar on soil chemical properties, maize nutrient and heavy metal uptake, growth and biomass partitioning on a tropical clayey soil. The study compared three organic amendments; sewage sludge (SS), sludge biochar (SB) and their combination (SS+SB) to the unamended control and inorganic fertilizers. Organic amendments were applied at a rate of 15 t ha–1 for SS and SB, and 7.5 t ha–1 each for SS and SB. Maize growth, biomass production and nutrient uptake were signiifcantly improved in biochar and sewage sludge amendments compared to the unamended control. Comparable results were observed with F, SS and SS+SB on maize growth at 49 d of sowing. Maize growth for SB, SS, SS+SB and F increased by 42, 53, 47, and 49%, respectively compared to the unamended control. Total biomass for SB, SS, SS+SB, and F increased by 270, 428, 329, and 429%, respectively compared with the unamended control. Biochar amendments reduced Pb, Cu and Zn uptakes by about 22% compared with sludge alone treatment in maize plants. However, there is need for future research based on the current pot experiment to determine whether the same results can be produced under ifeld conditions.

  12. Incineration of sewage sludge. Self-heating in storage silo; Incineration de boues d'epuration. Auto-echauffement dans les silos de stockage

    Energy Technology Data Exchange (ETDEWEB)

    Poffet, M.

    2008-07-01

    Elimination of urban sewage sludge occurs exclusively by incineration in Switzerland, because recycling as fertilizer in agriculture is banned since October 2006. This new elimination route is hampered, however, by the tendency of dried sewage granules to self-heating and by occasional thermal runaway ending up in fire. The presented research project deals with the investigation of the characteristics of this waste material and the possible reasons for the observed self-heating phenomenon. It was found that a cascade of reactions is responsible for the thermal runaway such as oxidation of ferrous (Fe{sup 2+}) and sulfides (S{sup 2-}) compounds and exothermic hydration which triggers the initial temperature raise. (author) $$$ continuer ici $$.

  13. Affective Urbanism

    DEFF Research Database (Denmark)

    Samson, Kristine

    Urban design and architecture are increasingly used as material and affective strategies for setting the scene, for manipulation and the production of urban life: The orchestration of atmospheres, the framing and staging of urban actions, the programming for contemplation, involvement, play......, experience and consumption are all strategic design tools applied by planners and architects. Whereas urban design in former modernist planning served merely functional or political means, urban design has increasingly become an aesthetical mediator of ideologies embedded in the urban field of life forces....... Under these circumstances affective aesthetics operate strategically within the urban field of interests, capital flows and desires of the social. This ‘affective urbanism’ (Anderson & Holden 2008) is linked to a society influenced by new kinds of information flows, where culture is mediated and enacted...

  14. Changing perspectives on the importance of urban phosphorus inputs as the cause of nutrient enrichment in Lough Neagh.

    Science.gov (United States)

    Foy, R H; Lennox, S D; Gibson, C E

    2003-07-01

    The scale and chronology of the phosphorus (P) enrichment of Lough Neagh, a large hypertrophic lake, was assessed using, as enrichment proxies, published palaeocological studies on diatoms and chironomid head capsules preserved in the lake sediments and, from 1974, monitoring data from the lake and its inflowing rivers. Enrichment commenced in 1880, and the scale and chronology of the diatom and chironomid records were similar up to 1960, but in the 1960s, chironomid accumulation rates increased dramatically, whereas diatom rates remained unchanged. From subsequent lake monitoring, the absence of a diatom response after 1960 was attributed to silica limitation so that P could be considered as the driver of increased diatom production only up to 1960. Using a coefficient for the demand for P by diatoms of 4 microg P mg SiO(2)(-1), it was calculated that the increased diatom production between 1881 and 1961 required an increase in lake P of 26 microg P l(-1). This value is close to the predicted increase of 22.5 microg P l(-1) in the lake caused by inputs of P from sewage treatment works and septic tanks. There was no evidence that diffuse source P contributed to enrichment over this period. Enrichment up to 1960 appears modest in comparison to subsequent years. From 1961 to 1974, lake P was estimated to have increased by 62 microg P l(-1), but only 25 microg P l(-1) of this increase was attributable to greater loadings of P from urban and septic tank sources. The enrichment response of chironomids at this time was also much greater than expected from a regression-derived relationship between urban P inputs and chironomid accumulation rates suggesting additional sources of P. The larger than expected increase in lake P was attributed to the onset of a significant internal loading of P and the commencement of an increase in diffuse source loadings of P. River monitoring has shown that diffuse P has increased steadily since 1974, more than counterbalancing a 40

  15. Rapid thermal conditioning of sewage sludge

    Science.gov (United States)

    Zheng, Jianhong

    Rapid thermal conditioning (RTC) is a developing technology recently applied to sewage sludge treatment. Sludge is heated rapidly to a reaction temperature (up to about 220sp°C) under sufficient pressure to maintain the liquid phase. Reaction is quenched after 10 to 30 seconds when the mixture of sludge and steam pass through a pressure let-down valve. This process reduces the amount of sludge requiring land disposal, eliminates the need for polymer coagulant, improves dewaterability, increases methane production, and further reduces the concentration of pathogens. The odor problem associated with traditional thermal conditioning processes is largely minimized. Ammonia removal is readily integrated with the process. For this research, a pilot unit was constructed capable of processing 90 liters of sludge per hour. Over 22 runs were made with this unit using sludge from New York City Water Pollution Control Plants (WPCP). Sludges processed in this equipment were tested to determine the effect of RTC operating conditions on sludge dewaterability, biodegradability, and other factors affecting the incorporation of RTC into wastewater treatment plants. Dewaterability of thermally conditioned sludge was assessed for cetrifugeability and filterability. Bench scale centrifugation was used for evaluating centrifugeability, pressure filtration and capillary suction time (CST) for filterability. A mathematical model developed for centrifuge dewatering was used to predict the effect of RTC on full scale centrifuge performance. Particle size distribution and solids density of raw and treated PDS were also analyzed. An observed increase in sludge solids density at least partially explains its improved centrifugeability. An investigation of thermally conditioned amino acids showed that the L-isomer is highly biodegradable while the D-isomers are generally less so. Glucose is highly biodegradable, but rapidly becomes refractory as thermal conditioning time is lengthened. This

  16. Distribution of sewage indicated by Clostridium perfringens at a deep-water disposal site after cessation of sewage disposal.

    OpenAIRE

    Hill, R T; Straube, W L; Palmisano, A C; Gibson, S L; Colwell, R R

    1996-01-01

    Clostridium perfringens, a marker of domestic sewage contamination, was enumerated in sediment samples obtained from the vicinity of the 106-Mile Site 1 month and 1 year after cessation of sewage disposal at this site. C. perfringens counts in sediments collected at the disposal site and from stations 26 nautical miles (ca. 48 km) and 50 nautical miles (ca. 92 km) to the southwest of the site were, in general, more than 10-fold higher than counts from an uncontaminated reference site. C. perf...

  17. A high rate clarifier for load levelling in sewerage systems.

    Science.gov (United States)

    Jago, R A; Davey, A; Li, H

    2003-01-01

    The combining of chemically assisted clarification with a proprietary physical separation technology has led to a high rate process for clarifying flocculated sewage and other waste streams. This hybrid physico-chemical system, known as the CDS Fine Solids Separation (FSS) System, was developed over a two year period within a sewage treatment plant environment. This paper summarises the results of a recent field trial of the system with a Victorian water authority which experiences heavy loading of sewers in a coastal town during holiday periods. The trial sought to evaluate the FSS as a tool for smoothing the load on the 11 km long sewer to the sewage treatment plant (STP). The FSS system could possibly enable the costly augmentation of the sewer to be deferred, particularly as the capacity of the existing sewer pipe is satisfactory for most of the year. Water quality parameters were determined for a range of flowrates and operational conditions over a two month period. Large reductions were achieved in TSS, TP, FC, turbidity and BOD5, with only minimal reductions in NH3 and TON. These results showed that the FSS could meet the authority's objectives for load levelling and would provide a 20-25% increase in effective sewer capacity. The data are also discussed in terms of possible use of the effluent from the FSS for water reuse applications.

  18. Beam loading

    OpenAIRE

    Boussard, Daniel

    1987-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superco...

  19. 40 CFR Appendix A to Part 503 - Procedure To Determine the Annual Whole Sludge Application Rate for a Sewage Sludge

    Science.gov (United States)

    2010-07-01

    ... Whole Sludge Application Rate for a Sewage Sludge A Appendix A to Part 503 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SEWAGE SLUDGE STANDARDS FOR THE USE OR DISPOSAL OF SEWAGE SLUDGE Pt... a Sewage Sludge Section 503.13(a)(4)(ii) requires that the product of the concentration for each...

  20. Evaluation of nonpoint-source contamination, Wisconsin: Land-use and Best-Management-Practices inventory, selected streamwater-quality data, urban-watershed quality assurance and quality control, constituent loads in rural streams, and snowmelt-runoff analysis, water year 1994

    Science.gov (United States)

    Walker, J.F.; Graczyk, D.J.; Corsi, S.R.; Owens, D.W.; Wierl, J.A.

    1995-01-01

    The objective of the watershed-management evaluation monitoring program in Wisconsin is to evaluate the effectiveness of best-management practices (BMP) for controlling nonpoint-source contamination in rural and urban watersheds. This report is an annual summary of the data collected for the program by the U.S Geological Survey and a report of the results of several different detailed analyses of the data. A land-use and BMP inventory is ongoing for 12 evaluation monitoring projects to track the sources of nonpoint-source pollution in each watershed and to document implementation of BMP's that may cause changes in the water quality of streams. Updated information is gathered each year, mapped, and stored in a geographic-information-system data base. Summaries of data collected during water years 1989-94 are presented. A water year is the period beginning October 1 and ending September 30; the water year is designated by the calendar year in which it ends. Suspended-sediment and total-phosphorus data (storm loads and annual loads) are summarized for eight rural sites. For all sites, the annual suspended-sediment or suspended-solids load for water year 1993 exceeded the average for the period of data collection; the minimum annual loads were transported in water year 1991 or 1992. Continuous dissolved-oxygen data were collected at seven rural sites during water year 1994. Data for water years 1990-93 are summarized and plotted in terms of percentage of time that a particular concentration is equaled or exceeded. Dissolved-oxygen concentrations in four streams were less than 9 mg/L at least 50 percent of the time, a condition that fails to meet suggested criterion for coldwater streams. The dissolved-oxygen probability curve for one of the coldwater streams is markedly different than the curves for the other streams, perhaps because of differences in aquatic biomass. Blank quality-assurance samples were collected at two of the urban evaluation monitoring sites to

  1. Evaluation of selected sewage sludge gasification technological parameters

    Science.gov (United States)

    Gałko, Grzegorz; Król, Danuta

    2018-02-01

    Evaluation of selected sewage sludge gasification technological parameters was shown in this paper. Degree of carbon conducted in combustible substance and syngas efficiency (technological readiness coefficient) in accordance with equations were calculated. Enthalpy of individual compounds formation and energy balance were calculated in accordance with rule of Hess.

  2. Effect of sewage oxidation pond effluent on macroinvertebrate ...

    African Journals Online (AJOL)

    The influence on aquatic macroinvertebrates of sewage oxidation pond effluent discharge was investigated in a tropical forest stream in Ile-Ife, Nigeria. A total of 858 individual macroinvertebrates were collected. They belong to 8 taxa which represent 5 orders. The number of taxa was low when compared to the findings in ...

  3. Focus on 14 sewage treatment plants in the Mpumalanga Province ...

    African Journals Online (AJOL)

    In order to identify the treatment methods used in different sewage treatment plants (STPs) in the Mpumalanga Province and to determine the efficiency of wastewater treatment by these plants, municipal STPs were surveyed, and raw and treated wastewater samples collected. A total of 14 STPs were visited and the ...

  4. Modeling of Evaporation Losses in Sewage Sludge Drying Bed ...

    African Journals Online (AJOL)

    A model for evaporation losses in sewage sludge drying bed was derived from first principles. This model was developed based on the reasoning that the rate at which evaporation is taking place is directly proportional to the instantaneous quantity of water in the sludge. The aim of this work was to develop a model to assist ...

  5. Wildlife health implications of sewage disposal in wetlands

    Science.gov (United States)

    Friend, M.; Godfrey, P.J.; Kaynor, E.R.; Pelczarski, S.

    1985-01-01

    Wildlife health concerns associated with disposal of sewage effluent in wetlands are of three primary types: (1) introduction of pathogens, (2) introduction of pollutants that adversely impact on host body defense mechanisms, and (3) changes in the physical and chemical properties of wetlands that favor the development and maintenance of disease problems. Unlike the situation with human health concerns, introduction of pathogens is not the major concern regarding wildlife health. Instead, the focus of attention needs to be directed at environmental changes likely to take place as a result of effluent discharges into different types of wetlands. Unless these changes are adequately addressed from a disease perspective, marshes utilized for sewage disposal could become disease incubators and wildlife death traps. This result would be unfortunate because the backlash would likely negate the potentially beneficial aspects of the use of sewage wastewater for the creation of new wetlands and have a severe impact on progress being made towards evaluation of the compatibility of wildlife and sewage effluents.

  6. Co-composting of sewage sludge and Echinochloa pyramidalis (Lam.)

    African Journals Online (AJOL)

    Yaoundé-Cameroon) in order to assess the effect of three sewage sludge: Macrophyte ratios on the co-composting process and compost quality. The ratios were T1: 25 kg of plant material (Echinochloa pyramidalis) and 75 kg sludge; T2: 50 kg ...

  7. Biodegradation of Lignocelluloses in Sewage Sludge Composting and Vermicomposting

    Directory of Open Access Journals (Sweden)

    Hosein Alidadi

    2012-08-01

    Full Text Available Please cite this article as: Alidadi H, Najafpour AA, Vafaee A, Parvaresh A, Peiravi R. Biodegradation of lignocelluloses in sewage sludge composting and vermicomposting. Arch Hyg Sci 2012;1(1:1-5.   Aims of the Study: The aim of this study was to determine the amount of lignin degradation and biodegradation of organic matter and change of biomass under compost and vermicomposting of sewage sludge. Materials & Methods: Sawdust was added to sewage sludge at 1:3 weight bases to Carbon to Nitrogen ratio of 25:1 for composting or vermicomposting. Lignin and volatile solids were determined at different periods, of 0, 10, 30, 40 and 60 days of composting or vermicomposting period to determine the biodegradation of lignocellulose to lignin. Results were expressed as mean of two replicates and the comparisons among means were made using the least significant difference test calculated (p <0.05. Results: After 60 days of experiment period, the initial lignin increased from 3.46% to 4.48% for compost and 3.46% to 5.27% for vermicompost. Biodegradation of lignocellulose was very slow in compost and vermicompost processes. Vermicomposting is a much faster process than compost to convert lignocellulose to lignin (p <0.05. Conclusions: The organic matter losses in sewage sludge composting and vermicomposting are due to the degradation of the lignin fractions. By increasing compost age, the amount of volatile solids will decrease.

  8. A steady state model for anaerobic digestion of sewage sludges ...

    African Journals Online (AJOL)

    A steady state model for anaerobic digestion of sewage sludge is developed that comprises three sequential parts – a kinetic part from which the % COD removal and ... and a carbonate system weak acid/base chemistry part from which the digester pH is calculated from the partial pressure of CO2 and alkalinity generated.

  9. Effects of Sewage Discharge on Polychaete Communities in East ...

    African Journals Online (AJOL)

    exposed to the discharge of sewage and two control assemblages. Journal of Experimental Marine Biology and. Ecology 189: 103-122. Chareonpanich C, Montani S, Tsutsumi H,. Matsuoka S (1993) Modification of chemical characteristics of organically enriched sediment by Capitella sp. Marine Pollution Bulletin 26: 375- ...

  10. Knowledge and practice of sewage disposal in Abattoir community ...

    African Journals Online (AJOL)

    Knowledge and practice of sewage disposal in Abattoir community of Jos South LGA, Plateau State, Nigeria. ... Conclusion: Despite the commendable findings in this community, the community is still at risk due to the poor practices of a few that were persisting in the community. Both government and community efforts are ...

  11. Leachability of fired clay brick incorporating with sewage sludge waste

    Science.gov (United States)

    Kadir, Aeslina Abdul; Salim, Nurul Salhana Abdul; Sarani, Noor Amira; Rahmat, Nur Aqma Izurin; Abdullah, Mohd Mustafa Al Bakri

    2017-09-01

    Sewage sludge is sewerage from wastewater treatment plants that generates millions tons of sludge ever year. Regarding this activity, it causes lack management of waste which is harmful to the surrounding conditions. Therefore, this study is focuses on the incorporation of sewage sludge waste into fired clay brick to provide an option of disposal method, producing adequate quality of brick as well as limiting the heavy metal leachability to the environment. Sewage sludge brick (SSB) mixtures were incorporated with 0%, 1%, 5%, 10%, 20% and 30% of sewage sludge waste (SSW). Heavy metals of crushed SSB were determined by using Toxicity Characteristic Leaching Procedure (TCLP) according to Method 1311 of United State Environment Protection Agency (USEPA) standard. From the results obtained, up to 20% of SSW could be incorporated into fired clay brick and comply with the USEPA standard. Therefore, this study revealed that by incorporating SSW into fired clay brick it could be an alternative method to dispose the SSW and also could act as a replacement material for brick manufacturing with appropriate mix and design.

  12. Potential for sustainable energy with biogas from sewage purification

    International Nuclear Information System (INIS)

    Coenen, J.; Van Gastel, M.; De Jong, K.

    2005-04-01

    Insight is given into the possibility to produce biogas from sewage purification plants in the Netherlands. Attention is paid to the estimated potential of sustainable energy from biogas, the economic effectiveness of several scenarios, the critical success factors and bottlenecks [nl

  13. Biological sulphate reduction with primary sewage sludge in an ...

    African Journals Online (AJOL)

    The success of the UASB reactor depends largely on the settling properties and stability of the sludge bed which comprises the anaerobic active biomass. The solid-liquid separation behaviour of the sludge bed in 2 UASB reactors (R1 at 35oC and R2 at 20oC) fed with primary sewage sludge and sulphate was investigated ...

  14. Phosphate Recovery From Sewage Sludge Containing Iron Phosphate

    NARCIS (Netherlands)

    Wilfert, P.K.

    2018-01-01

    The scope of this thesis was to lay the basis for a phosphate recovery technology that can be applied on sewage sludge containing iron phosphate. Such a technology should come with minimal changes to the existing sludge treatment configuration while keeping the use of chemicals or energy as small as

  15. [Contamination of protozoa by enteroviruses in fresh water and sewages].

    Science.gov (United States)

    Skachkov, M V; Al'misheva, A Sh; Plotnikov, A O; Nemtseva, N V; Skvortsov, V O

    2009-01-01

    To determine rate of infection of protozoa by enteroviruses to assess the potential role of protozoa as a natural reservoir of enteroviruses. The samples were collected from flowing and stagnant water reservoirs in Orenburg region in summer and autumn. The samples of sewages were taken in all stages of their treatment. Cultures of protozoa were isolated with micromanipulator equipped with micropipette, incubated on Pratt's medium at 25 degrees C and fed with Pseudomonas fluorescens culture. RNA of enteroviruses was detected by reverse transcription polymerase chain reaction (RT-PCR). Seventy-two protozoan species were found in Ural river, whereas 15 and 38 species were found in lakes and sewages respectively. Enteroviruses were detected by RT-PCR in 61.8% cultures of protozoa belonging to 23 species of flagellates, amoebae and ciliates isolated from natural water bodies undergoing anthropogenic impact as well as from sewages in all stages of their treatment. Predominant localization of enteroviruses in dominant taxons of protozoa (Paraphysomonas sp., Spumella sp., Petalomonas poosilla, Amoeba sp.) was noted. Obtained data confirm presence of enteroviruses in protozoa living both in flowing and stagnant recreation natural water bodies as well as in sewages and confirm the hypothesis of persistence of enteroviruses in protozoa and the reservoir role of the latter. Contingency of life cycles of viruses and protozoa allows to explain the seasonality of aseptic meningitis incidence caused by enteroviruses, which peaks in summer and autumn when protozoa massively multiply in water bodies.

  16. Socioeconomic constraints on the technological choices in rural sewage treatment.

    Science.gov (United States)

    Gu, Baojing; Fan, Liangcong; Ying, Zechun; Xu, Qingshan; Luo, Weidong; Ge, Ying; Scott, Steffanie; Chang, Jie

    2016-10-01

    Technological innovation is one of the potential engines to mitigate environmental pollution. However, the implementation of new technologies sometimes fails owing to socioeconomic constraints from different stakeholders. Thus, it is essential to analyze constraints of environmental technologies in order to build a pathway for their implementation. In this study, taking three technologies on rural sewage treatment in Hangzhou, China as a case study, i.e., wastewater treatment plant (WTP), constructed wetland (CW), and biogas system, we analyzed how socioeconomic constraints affect the technological choices. Results showed that socioeconomic constraints play a key role through changing the relative opportunity cost of inputs from government as compared to that of residents to deliver the public good-sewage treatment-under different economic levels. Economic level determines the technological choice, and the preferred sewage treatment technologies change from biogas system to CW and further to WTP along with the increase of economic level. Mismatch of technological choice and economic level results in failures of rural sewage treatment, e.g., the CW only work well in moderately developed regions in Hangzhou. This finding expands the environmental Kuznets law by introducing the coproduction theory into analysis (i.e., inputs from both government and residents are essential for the delivery of public goods and services such as good environmental quality). A match between technology and socioeconomic conditions is essential to the environmental governance.

  17. assessment of fecal bacteria contamination in sewage and non ...

    African Journals Online (AJOL)

    Mgina

    chemical parameters (temperature, pH, salinity and nutrients) were measured. ... Kijichi than Rasi Dege). No significant variation was noted on the values of temperature, pH and salinity. A significant correlation between the levels of fecal bacteria indicators and nutrient ... ocean e.g. sewage is discharged directly into.

  18. System control fuzzy neural sewage pumping stations using genetic algorithms

    Directory of Open Access Journals (Sweden)

    Владлен Николаевич Кузнецов

    2015-06-01

    Full Text Available It is considered the system of management of sewage pumping station with regulators based on a neuron network with fuzzy logic. Linguistic rules for the controller based on fuzzy logic, maintaining the level of effluent in the receiving tank within the prescribed limits are developed. The use of genetic algorithms for neuron network training is shown.

  19. Inactivation of bacteria in sewage sludge by gamma radiation

    International Nuclear Information System (INIS)

    Pandya, G.A.; Kapila, Smita; Kelkar, V.B.; Negi, Shobha; Modi, V.V.

    1987-01-01

    The survival of certain bacterial cultures suspended in sewage sludge and exposed to gamma-radiation was studied. The inactivation patterns of most of the organisms were significantly different when irradiation was performed using sewage samples collected in the summer and monsoon seasons. The summer sample collected from the anaerobic digester afforded significant protection to both Gram negative and Gram positive organisms. This was evident by the increase in dose required to bring about a 6 log cycle reduction in viable count of the bacterial cultures, when suspended in sewage samples instead of phosphate buffer. The observations made using monsoon digester samples were quite different. This sewage sludge greatly enhanced inactivation by gamma-radiation in most cases. The effects of certain chemicals on the inactivation patterns of two organisms - Salmonella typhi and Shigella flexneri - were examined. Arsenate, mercury and lead salts sensitised S. typhi, while barium acetate and sodium sulphide protected this culture against gamma-radiation. In the case of Sh. flexneri, barium acetate and iodacetamide proved to be radioprotectors. The effects of some chemicals on the inactivation pattern of Sh. flexneri cells irradiated in sludge are also discussed. (author)

  20. Utilisation of Electrodialytically Treated Sewage Sludge Ash in Mortar

    DEFF Research Database (Denmark)

    Kappel, Annemette; Pares Viader, Raimon; Kowalski, Krzysztof Piotr

    2018-01-01

    Phosphorous is a scarce resource and there is a need to develop methods for recovery of this irreplaceable nutrient from secondary resources, e.g. from sewage sludge ash (SSA). Today SSA is most often disposed of and the resource is lost. In the present study, about 90% phosphorous was recovered...